O.D. Range. Part # O.D. Range. Part #

Size: px
Start display at page:

Download "O.D. Range. Part # O.D. Range. Part #"

Transcription

1 6 SKINNER SKINNER-SEAL BAND CLAMP MODEL BCEC Snap Band Clamp Sizes 1/2 through 8 in 3 or 6 widths. Also 2-8 in 9, 12 width. Hardware Torque Specifications for Band Clamps 3/8 Bolts 1/2 to 1 1/2 OD FT-LBS 1/2 Bolts up to OD FT-LBS 5/8 Bolts over 4.74 OD FT-LBS 3 WIDE - 2 bolts Size 6 WIDE - 2 bolts 1/ $ $ / $ $ $ $ / $ $ / $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ WIDE - 3 bolts Size 12 WIDE - 4 bolts $ $ $ $ $ $ $ $ $

2 SKINNER-SEAL SKINNER 7 BAND CLAMP MODEL BCFC Full Circle Band Clamp Model BCFC Full Circle Band Clamp design is similar to the above Model BCEC Band Clamp but features a full circle gasket for added reliability. Installation Procedure: Size 3 WIDE - 1 bolt 6 WIDE - 2 bolts 1/ $ / $ $ / $ / $ $ SNAP CLAMPS (BCEC) WRAP CLAMPS (BCFC)

3 8 SKINNER SKINNER-SEAL BAND CLAMP MODEL BCSB All Stainless Steel Single Band Sizes 2 through 12 in 7.5 or 12.5 widths. Also 6, 10, 15, 20, 24, 30 width psi psi psi psi psi psi psi 6 WIDE - 2 bolts Size 7-1/2 WIDE - 2 bolts $ $ 1.00 $ $ 1.00 $ 1.00 $ 1.00 $ WIDE - 3 bolts Size $ * * 12-1/2 WIDE - 3 bolts / *4 bolts $ REPAIR CLAMPS (BCSB) 2-12 ALL STAINLESS STEEL CIRCLE REPAIR CLAMPS

4 SKINNER-SEAL SKINNER 9 BAND CLAMP MODEL BCSB All Stainless Steel Single Band (continued) 15 WIDE - 4 bolts Size $ $ WIDE - 6 bolts WIDE - 7 bolts Size $ WIDE - 9 bolts $1, Model BC-SB all Stainless Steel Single Section Band Clamp design allows for quick one-man installation. Excellent design for applications on corrosive materials or on buried water mains where corrosive soil is present. Bolts fit into lugs without removing nuts. Installation Procedure: Hardware Torque Specifications for Band Clamps 3/8 Bolts 1/2 to 1 1/2 OD FT-LBS 1/2 Bolts up to OD FT-LBS 5/8 Bolts over 4.74 OD FT-LBS

5 10 SKINNER SKINNER-SEAL BAND CLAMP MODEL BCDB All Stainless Steel Double Band Nuts Steel widths Sizes 10 through 16 in 10 or 12.5 widths. Also 10, 15, 20, 24, 30 width psi psi psi psi psi psi psi 7-1/2 WIDE - 4 bolts Size * * * * 12-1/2 WIDE - 6 bolts / *8 bolts WIDE - 6 bolts Size WIDE - 8 bolts $.00 $

6 SKINNER-SEAL SKINNER 11 BAND CLAMP MODEL BCDB All Stainless Steel Double Band (continued) 20 WIDE - 12 bolts Size $ WIDE - 14 bolts WIDE - 18 bolts $.00 $ Model BC-DB all Stainless Steel Double Band Clamp design allows for quick one-man installation. Excellent design for applications on corrosive materials or on buried water mains where corrosive soil is present. Bolts fit into lugs without removing nuts. Installation Procedure: Hardware Torque Specifications for Band Clamps 3/8 Bolts 1/2 to 1 1/2 OD FT-LBS 1/2 Bolts up to OD FT-LBS 5/8 Bolts over 4.74 OD FT-LBS REPAIR CLAMPS (BCDB) 4-16 TWO SECTION WIDER RANGE ALL STAINLESS STEEL REPAIR CLAMPS

7 12 SKINNER SKINNER-SEAL BAND CLAMP MODEL BCTB All Stainless Steel Triple Band 18-8 type 304 stainless steel band 18-8 type 304 stainless steel nuts & bolts Gasket material is Buna-N rubber Side bars and lifter bar 188 stainless steel Temperature Rating: 250 F 12 1/2 WIDE - 12 bolts / *16 bolts 15 WIDE - 12 bolts / *16 bolts 20 WIDE - 18 bolts / *24 bolts Size $1, $1, $1, $1, $1, $2, $1, $1, $2, $1, $2, $3, $2, $2, $3, * $4, * $5, * $5, Size 24 WIDE - 21 bolts / *28 bolts 30 WIDE - 27 bolts / *36 bolts $2, $3, $2, $3, $2, $3, $4, $5, $5, $6, * $6, * $7,

8 SKINNER-SEAL SKINNER 13 BAND CLAMP MODEL BCTB All Stainless Steel Triple Band (continued) Model BC-TB all Stainless Steel Double Band Clamp design allows for quick one-man installation. Excellent design for applications on corrosive materials or on buried water mains where corrosive soil is present. Bolts fit into lugs without removing nuts. Installation Procedure: Thoroughly clean the damaged area with a wire brush. This will assure a bubble tight gasket seal. Back off the nuts to the ends of the bolt, but do not remove them. Separate the clamp halves. Center the clamp gasket over the area that needs repair. Make sure the gasket extends past damaged area. Relocate the bolt heads securely into their receiving lugs. Pressure test for leaks before leaving area. Hardware Torque Specifications for Band Clamps 3/8 Bolts 1/2 to 1 1/2 OD FT-LBS 1/2 Bolts up to OD FT-LBS 5/8 Bolts over 4.74 OD FT-LBS

Stargrip series 3000 Mechanical Joint Wedge Action Restraint for Ductile Iron Pipe

Stargrip series 3000 Mechanical Joint Wedge Action Restraint for Ductile Iron Pipe Stargrip series 3000 Mechanical Joint Wedge Action Restraint for Ductile Iron Pipe INFORMATION The Stargrip Mechanical Joint Restraint System is a unique product with a proven design that provides an exceptional

More information

Castle Frame Assembly Table AT-8. Diagnostics Manual. Castle, Inc. Petaluma, CA

Castle Frame Assembly Table AT-8. Diagnostics Manual. Castle, Inc. Petaluma, CA Castle Frame Assembly Table AT-8 Diagnostics Manual Castle, Inc. Petaluma, CA 800-282-8338 Solutions Index Adjusting the Tabletop.. 8.01 Adjusting the Fence... 8.02 Aligning the Arm... 8.10 Adjusting Bracket..

More information

REPAIR CLAMP PARTS H fax: MULTIPLIER

REPAIR CLAMP PARTS H fax: MULTIPLIER REPAIR CLAMP PARTS Part Number Component Description Model Number Product Size List Price Unit V001 Neoprene Sheet Gasket AS All Sizes Square Inch V002 Waffle Pattern Gasket (NBR) AS All Sizes Square Inch

More information

Pipe Restraints and Adapter Flanges. Section U. For PVC, Ductile Iron and Steel Pipe. 09/2017 Web Revision

Pipe Restraints and Adapter Flanges. Section U. For PVC, Ductile Iron and Steel Pipe. 09/2017 Web Revision DQS Inc. THE FORD METER BOX COMPANY, INC. CERTIFIED TO ISO 9001:2015 10004466 Section U 09/2017 Web Revision 11-29-17 Restraints and Adapter Flanges For PVC, Ductile Iron and Steel Contents Applications

More information

INSTRUCTIONS FOR AIRFLEX 36WCBEP/36WCSEP WEAR PLATE REPLACEMENT USING GASKET SEALING TAPE

INSTRUCTIONS FOR AIRFLEX 36WCBEP/36WCSEP WEAR PLATE REPLACEMENT USING GASKET SEALING TAPE INSTRUCTIONS FOR AIRFLEX 36WCBEP/36WCSEP WEAR PLATE REPLACEMENT USING GASKET SEALING TAPE The material included in this kit is to be used for WC styles of brakes that are designed or upgraded to the EP

More information

Pipe Restrainers series C Restrainers for use on IPEX Bionax AWWA CI OD C909 PVCO Pipe with MJ or Push-On Fittings

Pipe Restrainers series C Restrainers for use on IPEX Bionax AWWA CI OD C909 PVCO Pipe with MJ or Push-On Fittings Pipe Restrainers series 1000 1000C Restrainers for use on IPEX Bionax AWWA CI OD C909 PVCO Pipe with MJ or Push-On Fittings INFORMATION Restrainers for restraining mechanical joint or push-on fittings

More information

4-8 HSF 250 Patriot. Line Stop Fitting Installation Instructions. Installation Instructions and Best Practices continued on back

4-8 HSF 250 Patriot. Line Stop Fitting Installation Instructions. Installation Instructions and Best Practices continued on back HSF 250 Patriot Heavy Duty Line Stop Fitting - 4, 6, 8 inch Nominal Sizes Line Stop Fitting Installation Instructions Push and Pin Completion Plug Installation Instructions IMPORTANT: Read installation

More information

AF-4 Grooved Flange Adapter

AF-4 Grooved Flange Adapter SUBMITTAL INFORMATION PROJECT NAME: ENGINEER: CONTRACTOR: SPEC. SECTION: MEMBER FEATURES & ADVANTAGES Designed for connecting ANSI/AWWA C110/A21.10 and ASME/ANSI B16.1 Class 125/ flanged end components

More information

Hose Accessories. "Air King" 4 - Lug Quick-Acting Couplings. Hose End. Female N.P.T. End

Hose Accessories. Air King 4 - Lug Quick-Acting Couplings. Hose End. Female N.P.T. End "Air King" 4 - Lug Quick-Acting 1¼" 1½" AM16 AM AM6 AB16~ AB~ AB6 End Rubber Washers for 4-Lug AWR14 Fits all sizes 1¼" 1½" AM18 AM3 AM8 AB18~ AB3 AB8 Rated to 1 PSI Female N.P.T. End "Boss" clamps recommended

More information

INSTALLATION INSTRUCTIONS PART#:17A045200MSS\17A045200MA MODULAR GRILL GUARD FOR FORD SUPER DUTY F250/F

INSTALLATION INSTRUCTIONS PART#:17A045200MSS\17A045200MA MODULAR GRILL GUARD FOR FORD SUPER DUTY F250/F INSTALLATION INSTRUCTIONS PART#:17A045200MSS\17A045200MA MODULAR GRILL GUARD FOR FORD SUPER DUTY F250/F350 08-09 1 guard, center section 1 brush guard, left side 1 brush guard, right side 1 wire guard

More information

12-16 Ft Wide Enclosure Assembly Guide

12-16 Ft Wide Enclosure Assembly Guide www.rmfiberglass.com 12-16 Ft Wide Enclosure Assembly Guide RM Products Ltd 1-800-363-0867 www.rmfiberglass.com Handling and Storage 2 P a g e Handling and Storage: 3 P a g e Before You Begin Contact RM

More information

MUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extention Sections. Reliable Connections

MUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extention Sections. Reliable Connections insertion Instructions manual MUELLER Improved, Centurion Series, Modern Improved, and 107 table of contents PAGE Centurion Series Fire Hydrant Adding an Extention 2-3 Improved Fire Hydrant Inserting Extention

More information

VALVTECHNOLOGIES, INC. INSTALLATION, OPERATIONS & MAINTENANCE MANUAL STEAM CHOKE VALVES

VALVTECHNOLOGIES, INC. INSTALLATION, OPERATIONS & MAINTENANCE MANUAL STEAM CHOKE VALVES VALVTECHNOLOGIES, INC. INSTALLATION, OPERATIONS & MAINTENANCE MANUAL STEAM CHOKE VALVES Page STEAM CHOKE VALVES The Valvtechnologies steam choke is designed for the harsh conditions associated with steam

More information

.84M Ku-Band Rx/O Antenna System

.84M Ku-Band Rx/O Antenna System 4096-644 Revision A May 9, 2003 ASSEMBLY MANUAL.84M Ku-Band Rx/O Antenna System PRODELIN CORPORATION 1500 PRODELIN DRIVE NEWTON, NC 28658 .84M Ku-Band Rx/O Antenna System A ORIGINAL RELEASE 5/9/2003 A.Hahn

More information

SYGEF Standard SYGEF Plus PVDF Flanges

SYGEF Standard SYGEF Plus PVDF Flanges Installation Instructions 2009 Volume, Rev 02 PM451 SYGEF Standard SYGEF Plus PVDF Flanges Please read all instructions before attempting to install flanges. Introduction When to Use a Flange Flanges may

More information

Assmann Corporation of America TANK INSTALLATION AND USE GUIDELINES FOR BULK STORAGE TANKS

Assmann Corporation of America TANK INSTALLATION AND USE GUIDELINES FOR BULK STORAGE TANKS Assmann Corporation of America TANK INSTALLATION AND USE GUIDELINES FOR BULK STORAGE TANKS General Information Assmann polyethylene storage tanks are manufactured to give you the toughest, most reliable

More information

The Redi-Flange Method. How It Works. Services. Engineering & Costing Assistance

The Redi-Flange Method. How It Works. Services. Engineering & Costing Assistance ... g n ldi ng... e i W No hread ing! T oov o N Gr o N The Redi-Flange Method Redi-Flange is a method of joining valves, fi ttings and equipment with integral fl anged ends to plain-ended pipe, with all

More information

I-W07/W77. Couplings DETAIL A WARNING. Photo Showing Pipe with Weld Seam Ground 6 inches/152 mm Back from Pipe End and an AGS Groove

I-W07/W77. Couplings DETAIL A WARNING. Photo Showing Pipe with Weld Seam Ground 6 inches/152 mm Back from Pipe End and an AGS Groove WARNING Read and understand all instructions before attempting to install any Victaulic piping products. These products must be used only on pipe that is prepared to Victaulic Advanced Groove System (AGS)

More information

Installing a COMROD AS1R Whip Antenna with Anchor Post

Installing a COMROD AS1R Whip Antenna with Anchor Post Installing a COMROD AS1R Whip Antenna with Anchor Post IS10012 Issue 1.0...15 September 2010 Nautel Limited 10089 Peggy's Cove Road, Hackett's Cove, NS, Canada B3Z 3J4 T.877 6 nautel (628835) or +1.902.823.2233

More information

FIELD LOK 350. Gasket 4" 24" JOINT RESTRAINT NSF FOR WATER & WASTEWATER, FIRE PROTECTION & INDUSTRIAL APPLICATIONS. Certified to ANSI/NSF 61

FIELD LOK 350. Gasket 4 24 JOINT RESTRAINT NSF FOR WATER & WASTEWATER, FIRE PROTECTION & INDUSTRIAL APPLICATIONS. Certified to ANSI/NSF 61 4" 24" FIELD LOK 350 JOINT RESTRAINT Gasket FOR WATER & WASTEWATER, FIRE ROTECTION & INDUSTRIAL ALICATIONS 4" 24" FIELD LOK 350 Gasket 2 Table of Contents FIELD LOK 350 Gasket 3 Assembly 4 Alternative

More information

Ford Water Meter Couplings & Accessories

Ford Water Meter Couplings & Accessories Section H 2/2001 Ford Water Meter Couplings & Accessories The Ford Meter Box Co., Inc. 775 Manchester Avenue, P.O. Box 443, Wabash, Indiana, USA 46992-0443 Telephone: 260/563-3171 FAX: 1-800-826-3487 Overseas

More information

Halsey Taylor Owners Manual

Halsey Taylor Owners Manual Halsey Taylor Owners Manual Wall Mount Steel Fountains ITALLER These series fountains are among the easiest to install Fountains on the market today. To assure you install these models easily and correctly,

More information

GUIDELINES FOR HINGED AND BOLTED MANWAY ASSEMBLY

GUIDELINES FOR HINGED AND BOLTED MANWAY ASSEMBLY GUIDELINES FOR HINGED AND BOLTED MANWAY ASSEMBLY Assembly Instructions for the Flammable Liquid Industry Published by: Renewable Fuels Association Authored by: Watco Compliance Services, VSP Technologies,

More information

INSTALLATION INSTRUCTIONS PART#:17A096400MSS\17A096400MA MODULAR GRILL GUARD FOR TOYOTA TACOMA 05-09

INSTALLATION INSTRUCTIONS PART#:17A096400MSS\17A096400MA MODULAR GRILL GUARD FOR TOYOTA TACOMA 05-09 INSTALLATION INSTRUCTIONS PART#:17A096400MSS\17A096400MA MODULAR GRILL GUARD FOR TOYOTA TACOMA 05-09 1 guard, center section 1 brush guard, left side 1 brush guard, right side 1 wire guard insert, left

More information

Air Hose Products.

Air Hose Products. Air Hose Products 1.1 Bulk Red Air Hose 1.2 Jackhammer Hose Assemblies 1.3 Air Tool Hose Assemblies 1.4 Hot Air Blower Hose 1.5 Yellow Wire Braid Air Hose Assemblies and Fittings 1.6 Air Hose Fittings

More information

UPPER DOOR KIT P/N APPLICATION BEFORE YOU BEGIN ITEMS MARKED (*) ARE INCLUDED IN HARDWARE KIT PN P/N Rev 01 07/14 Page 1 of 6

UPPER DOOR KIT P/N APPLICATION BEFORE YOU BEGIN ITEMS MARKED (*) ARE INCLUDED IN HARDWARE KIT PN P/N Rev 01 07/14 Page 1 of 6 UPPER DOOR KIT P/N 2880609 APPLICATION RZR 900 BEFORE YOU BEGIN Read these instructions thoroughly and make sure all parts and tools are accounted for. Please retain these installation instructions for

More information

Figure 11 Flange Adapter and Back-Up Ring

Figure 11 Flange Adapter and Back-Up Ring Flange Adapters Standard back-up rings are Standard back-up rings are convoluted ductile iron with AWWA C207 150 lb drilling. One edge of the back-up ring bore must be radiused or chamfered. This edge

More information

TOOLS AND INSTALLATION

TOOLS AND INSTALLATION TOOLS AND INSTALLATION Safe, leak-free operation of any high-pressure system is dependent on correctly prepared and installed connections. This section outlines proper instructions for the machining and

More information

FITTINGS & GAUGES 20,000 PSI

FITTINGS & GAUGES 20,000 PSI PRESSURE GAUGE Features 4" high visibility face with laminated safety glass dial cover Accurate within +/- 0.5% of full scale range Stainless steel case and internals Heavy-duty movement Glycerine-filled

More information

Auto-Spreader Spreader HS10K Hydraulic Flange Spreader

Auto-Spreader Spreader HS10K Hydraulic Flange Spreader Auto-Spreader Spreader HS10K Hydraulic Flange Spreader US Patent No. 5678293 Operation and Maintenance Manual Keep For Your Records Contents Operation...2 Maximum Spreader Extension...3 Safety Tips...4

More information

MUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extension Sections. Reliable Connections

MUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extension Sections. Reliable Connections insertion Instructions manual MUELLER Improved, Centurion Series, Modern Improved, and 107 table of contents PAGE Centurion Series Fire Hydrant Adding an Extension 2-3 Improved Fire Hydrant Inserting Extension

More information

GENERAL PROVISIONS OF THE SPECIFICATIONS MATERIAL SPECIFICATIONS LIST

GENERAL PROVISIONS OF THE SPECIFICATIONS MATERIAL SPECIFICATIONS LIST GENERAL PROVISIONS OF THE SPECIFICATIONS MATERIAL SPECIFICATIONS LIST 1a. PIPE (PVCO): P.W. Eagle 200 PSI in accordance with AWWA C909. Use class 200 unless otherwise approved. Water Pipe Main Diameter

More information

Installation, Operation, Inspection and Maintenance Manual

Installation, Operation, Inspection and Maintenance Manual Installation, Operation, Inspection and Maintenance Manual System: KTM 1 Table of Contents 1.0 Introduction... 2 1.1 Precautions... 2 1.2 Regulations... 2 1.3 Technical Specifications... 2 1.4 Required

More information

Engineering Data Single Reduction Parts List Item # Description Basic Single Reduction Unit 1. Gear Housing 2. Pipe Plug 3. Vent Plug 4. Splash Guard

Engineering Data Single Reduction Parts List Item # Description Basic Single Reduction Unit 1. Gear Housing 2. Pipe Plug 3. Vent Plug 4. Splash Guard Engineering Data Single Reduction Parts List Item # Description Basic Single Reduction Unit 1. Gear Housing 2. Pipe Plug 3. Vent Plug 4. Splash Guard 5. Input Cover 6. O-Ring 7. Hex Head Cap Screw 8. Input

More information

Typical Group D Rear Acoustical Cover Installation

Typical Group D Rear Acoustical Cover Installation SERIES 60 SERVICE MANUAL 1. Gear Case Cover 5. Bolt 2. Gear Case 6. Acoustical Cover 3. Acoustical Cover Snap 7. Acoustical Cover 4. Acoustical Cover Clip 8. Nut Figure 1-179 Typical Group D Rear Acoustical

More information

May 14, Installation Manual

May 14, Installation Manual May 14, 2012 Installation Manual Contents MAG TRACKER Components...1 Mount Installation...7 Module Installation & Grounding...11 Maintenance...14 Warranty......14 Contact Information......14 May 14, 2012

More information

NTTC Tank Truck Week Awareness Gaskets/Fasteners/Flanges

NTTC Tank Truck Week Awareness Gaskets/Fasteners/Flanges NTTC Tank Truck Week 2015 Awareness Gaskets/Fasteners/Flanges OVERVIEW 1. Flange 101 Flange Types Inspection & Assembly 2. Gaskets 101 Stress Tightness 3. Fastener 101 Yield Lubrication Bolted Flanged

More information

Reliance SG800 Series Steel Water Gage Valves

Reliance SG800 Series Steel Water Gage Valves Installation, Operation, & Maintenance Instructions R500.541D1 10/16/2016 Reliance SG800 Series Steel Water Gage Valves Note: Design variations in Steel Water Gage Valves necessitate typical illustrations,

More information

Patented Rail-Free Mounting System for Composition/Asphalt Shingle Roofs

Patented Rail-Free Mounting System for Composition/Asphalt Shingle Roofs Quick Start Guide Patented Rail-Free Mounting System for Composition/Asphalt Shingle Roofs R ESPECT T HE R OOF Quick Rack Components & Tools Components are pre-assembled and ready for installation right

More information

AFB (AIR FAN BEARING) INSTALLATION GUIDE

AFB (AIR FAN BEARING) INSTALLATION GUIDE 654 AFB (AIR FAN BEARING) INSTALLATION GUIDE AFB PARTS Bearing Housing - Secured together with two 3/8 x 1.25 in. Cap Screws Black Wiper Seals - Secured together with O-ring cord (Subsequently depicted

More information

General Information. Ball Curb Valve

General Information. Ball Curb Valve General Information 1. All Jones Curb Valves are manufactured in accordance with the AWWA Standard C-800-latest revision. 1. Copper Alloy CDA No. C83600 (85-5-5-5) 2. Copper Alloy CDA No. 89520 (Low Lead)

More information

INSTALLATION MANUAL FRONT. See pages 2 and 3 of this manual for configuration options. Level of Difficulty. Product Photo (center section only)

INSTALLATION MANUAL FRONT. See pages 2 and 3 of this manual for configuration options. Level of Difficulty. Product Photo (center section only) INSTALLATION MANUAL FRONT Level of Difficulty Moderate Product Photo (center section only) All hardware listed below will be provided with the bumpers center section. Additional hardware will be supplied

More information

PROCEDURE:INSTALLATION OF BOLTED AND THREADED CONNECTIONS. as a result of improper lifting technique.

PROCEDURE:INSTALLATION OF BOLTED AND THREADED CONNECTIONS. as a result of improper lifting technique. RISK RANKING: LOW HAZARD ASSESSMENT: HAZARD 1. Improper use of tools or using faulty tools. 2. Physical strain. POTENTIAL EFFECTS 1. Worker could suffer personal injury if not using tools properly. 2.

More information

Free Standing Pedestal Mounting Installation Manual

Free Standing Pedestal Mounting Installation Manual Free Standing Pedestal Mounting Installation Manual Articulated Jib Crane KickLIFT Page 1 of 5 INSTALLATION GENERAL INSTALLATION INSTRUCTIONS All AIMCO lift assist equipment and associated tooling is assembled

More information

Students will assemble and disassemble cast iron pipe and fittings according to provided specifications.

Students will assemble and disassemble cast iron pipe and fittings according to provided specifications. Plumber Description Students will assemble and disassemble cast iron pipe and fittings according to provided specifications. Lesson Outcomes The student will be able to: Assemble cast iron pipe and fittings

More information

RBP-1215B-RX DODGE RAM QUAD CAB RX3

RBP-1215B-RX DODGE RAM QUAD CAB RX3 RBP-1215B-RX3 2002-2017 DODGE RAM 15-3500 QUAD CAB RX3 Passenger side RX-3 Side Step Drill Template Passenger side rear Modular Bracket (6) L Support Brackets Driver side rear Modular Bracket Driver side

More information

New Product Release: October 2014 Boone Racks

New Product Release: October 2014 Boone Racks New Product Release: October 2014 Boone Racks Double Fido Fountain Mounting: Surface NOTE: THESE ROUGH-IN DIMENSIONS MAY VARY ½: (13 mm) PLUS OR MINUS NOTE: All dimensions subject to manufacturing variance

More information

ONE-LOK Series SLC/SLCE Pipe Restraint for AWWA C909 PVC Pipe

ONE-LOK Series SLC/SLCE Pipe Restraint for AWWA C909 PVC Pipe ONE-LOK Series SLC/SLCE Restraint for AWWA Use the SIGMA ONE-LOK Series SLC/SLCE restraint for AWWA pipe at mechanical or push-on joint ductile iron fittings. The ONE-LOK Restraint Systems can successfully

More information

OTECO INC. MODEL ,000 PSI 4-1/16 PORT DM GATE VALVE MAINTENANCE MANUAL

OTECO INC. MODEL ,000 PSI 4-1/16 PORT DM GATE VALVE MAINTENANCE MANUAL Page 1 of 7 OTECO INC. MODEL 45 4 5,000 PSI 4-1/16 PORT DM GATE VALVE MAINTENANCE MANUAL Page 2 of 7 TABLE OF CONTENTS 1. Assembly Blowout 2. Repair Kit Contents & Technical Specifications 3. Disassembly

More information

GH BETTIS SERVICE INSTRUCTIONS DISASSEMBLY & REASSEMBLY FOR MODEL F10207 DOUBLE ACTING HYDRAULIC ACTUATOR

GH BETTIS SERVICE INSTRUCTIONS DISASSEMBLY & REASSEMBLY FOR MODEL F10207 DOUBLE ACTING HYDRAULIC ACTUATOR GH BETTIS SERVICE INSTRUCTIONS DISASSEMBLY & REASSEMBLY FOR MODEL F10207 DOUBLE ACTING HYDRAULIC ACTUATOR PART NUMBER: 074960 REVISION: "A" RELEASE DATE: NOVEMBER, 1991 Page 1 of 6 1.0 INTRODUCTION 1.1

More information

CUTTING THE PIPE: BLUE DUCT Pipe can be easily cut using a Circular Saw or Reciprocal Saw. Trim all edges as necessary.

CUTTING THE PIPE: BLUE DUCT Pipe can be easily cut using a Circular Saw or Reciprocal Saw. Trim all edges as necessary. Installation Instructions In the past it has been IMPOSSIBLE to install an air and water tight underground system. BLUE DUCT (AKDUCT ) has produced a user friendly system that will reduce the amount of

More information

2-Inch Thermoplastic Dewatering Pumps Refer to pump manual for General Operating and Safety Instructions.

2-Inch Thermoplastic Dewatering Pumps Refer to pump manual for General Operating and Safety Instructions. Specifications Information and Repair Parts Manual 3824-99, 3825-99 & 382A-99 Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting

More information

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

5/16 Flange nut. Bolt Keeper Plate (8 Sq. SYS.) (3) 1/2 x 3 Hex head connector zinc plated bolt w/ washers and nut. Anchor 3 sq. 7 Ga. 2 1/2" x 2 1/2" x 10 Ga. 6" 5" 4" Variable Slipbase (8" Sq. SYS.) 5/16 Corner Bolt W/ nut 5/16" Flange nut Stub Insert (8" Sq. SYS.) Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc

More information

MECH-100: Fundamentals of Precision Maintenance

MECH-100: Fundamentals of Precision Maintenance MECH-100: Fundamentals of Precision Maintenance Universal Technologies, Inc. Student Guide Page 1 Torquing Topic Goals... 3 Introduction... 4 JOINT PRELOAD... 4 BOLT PRELOAD... 6 PRELOAD SEQUENCING...

More information

KEEP YOUR RESOURCE MOVING.

KEEP YOUR RESOURCE MOVING. LINER BOLTS KEEP YOUR RESOURCE MOVING. COLUMBUS McKINNON CORPORATION Leading the Industry Downtime in the grinding mill operation is caused by one of two things: regularly scheduled maintenance or unscheduled

More information

FOR WATER & WASTEWATER, FIRE PROTECTION & INDUSTRIAL APPLICATIONS

FOR WATER & WASTEWATER, FIRE PROTECTION & INDUSTRIAL APPLICATIONS JOINT RESTRAINT (4" - 24") Gasket FOR WATER & WASTEWATER, FIRE ROTECTION & INDUSTRIAL ALICATIONS 866.DI.IE 2 Table of Contents Gasket 3 Assembly 4 Alternative Assembly Methods 7 ipe Diameters 8 Assembly

More information

1. The electrodes are comprised of four main parts: the PEEK piece, glass rod, bolt and stainless steel rod.

1. The electrodes are comprised of four main parts: the PEEK piece, glass rod, bolt and stainless steel rod. Assembly of dual immersion corrosion cell electrode mount 1. The electrodes are comprised of four main parts: the PEEK piece, glass rod, bolt and stainless steel rod. Figure 1. From left: PEEK piece, glass

More information

SAFETY PRECAUTIONS GENERAL INFORMATION

SAFETY PRECAUTIONS GENERAL INFORMATION Form No. 102831 SPX Corporation 5885 11th Street Rockford, IL 61109-3699 USA Internet Address: http://www.hytec.com Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800)

More information

Evaluation of In-Pavement Light Fixture Designs and Performance

Evaluation of In-Pavement Light Fixture Designs and Performance Evaluation of In-Pavement Light Fixture Designs and Performance Presented to: IES ALC Fall Technology Meeting By: Joseph Breen Date: Background In-Pavement Light Fixture Assemblies Utilize a Circle of

More information

UPPER DOOR KIT P/N

UPPER DOOR KIT P/N UPPER DOOR KIT P/N 2879946 Application RZR XP4 1000 Before you begin, read these instructions twice and check to be sure all parts and tools are accounted for. Please retain these installation instructions

More information

Steep-Slope ApplicAtionS

Steep-Slope ApplicAtionS Steep-Slope ApplicAtionS GreenFasten GF1 PRODUCT GUIDE Exploded Product View/B.O.M. 1 Installation Instructions 2 Cut Sheets 3 Specifications 4 Test Data 5 Price List 6 Exploded Product View, Bill of Materials

More information

Installation Instructions

Installation Instructions The IMS ETERNAL FIX PATENT PENDING Installation Instructions EPS recommends professional installation for the Eternal IMS Fix. Please take all precautionary safety measures. We also recommend putting the

More information

SS Band for increased durability (except 1/2 inch) 4000 PSI

SS Band for increased durability (except 1/2 inch) 4000 PSI COUPLERS Legacy Quick Couplers Legacy Brass Couplers give Premium Performance with Economy Price. Legacy Quick Connect Couplings are machined from top grade materials to the same exacting specifications

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS TEL:1-866-XANATOS INSTALLATION INSTRUCTIONS PART#: 17A110200MSS\17A110200MA MODULAR GRILL GUARD FOR NISSAN FRONTIER 05-10//PATHFINDER 05-07 1 guard, center section 1 brush guard, left side 1 brush guard,

More information

MAASS Model J and JC Style PITLESS ACCESSORY OPTIONS

MAASS Model J and JC Style PITLESS ACCESSORY OPTIONS MAASS Model J and JC Style PITLESS ACCESSORY OPTIONS MADE in the USA PA Option with #370 Pressure Relief Valve PA (PITLESS ACCESSORY) OPTION Now available for Maass 1 Model J or JC Style Adapters, a 1/2

More information

PO STYLE AIR CLUTCH INSTALLATION AND MAINTENANCE MANUAL

PO STYLE AIR CLUTCH INSTALLATION AND MAINTENANCE MANUAL PO STYLE AIR CLUTCH INSTALLATION AND MAINTENANCE MANUAL P.O. Box 8148 Wichita Falls, Texas 76307 1600 Fisher Rd. Wichita Falls, Texas 76305 Phone: (940) 761-1971 Fax: (940) 761-1989 www.wptpower.com email:

More information

SolarMount (E)volution

SolarMount (E)volution SolarMount (E)volution SOLARMOUNT (E)VOLUTION: THE BEST JUST GOT BETTER. Engineering, Excellence, and Ease. Performance Engineered for versatility and reduced installation time, SolarMount (E)volution

More information

Installation Instructions TMW Antenna Tower Mount for 4ft (1.2m) Antennas.

Installation Instructions TMW Antenna Tower Mount for 4ft (1.2m) Antennas. Description The following pages show the steps required to assembly and fit the antenna mount to a vertical tower pipe of diameter 48 to 115 mm (1.9 to 4.5"). This mount provides ±20 azimuth or ±15 elevation

More information

INSTALLATION INSTRUCTIONS PART#:17GT23MSS\17GT23MA MODULAR GRILL GUARD FOR CHEVY SILVERADO 1/2 TON 99-02

INSTALLATION INSTRUCTIONS PART#:17GT23MSS\17GT23MA MODULAR GRILL GUARD FOR CHEVY SILVERADO 1/2 TON 99-02 INSTALLATION INSTRUCTIONS PART#:17GT23MSS\17GT23MA MODULAR GRILL GUARD FOR CHEVY SILVERADO 1/2 TON 99-02 1 guard, center section 1 brush guard, left side 1 brush guard, right side 1 wire guard insert,

More information

THE SCOUT WOOD-DECK ANCHOR

THE SCOUT WOOD-DECK ANCHOR THE SCOUT WOOD-DECK ANCHOR 1.95" SCOUT POOL LIFT (SOLD SEPARATELY) 6" 6" [356mm] 14" [152mm] 6" [406mm] 16" OC [368mm] 14 1/8" WOODEN OR SYNTHETIC DECKING BOLT COPPER BONDING-LUG (ANY OF FOUR CORNERS)

More information

FXL-168 FIXED RACK ASSEMBLY INSTRUCTIONS SALES ORDER #

FXL-168 FIXED RACK ASSEMBLY INSTRUCTIONS SALES ORDER # ZOMEWORKS FXL-168 FIXED RACK ASSEMBLY INSTRUCTIONS SALES ORDER # 1 1011 Sawmill Road NW, PO Box 25805, Albuquerque, NM 87125 USA (505) 242-5354 / (800) 279-6342 / FAX (505) 243-5187 E-mail: zomework@zomeworks.com

More information

PIPE/CONDUIT SUPPORTS

PIPE/CONDUIT SUPPORTS PIPE/CONDUIT SUPPORTS Pipe/Conduit Clamps...102-105 Unicushion... 106 Pipe & Tubing (Cush-A-Clamp ) Clamps...107-110 Pipe Hangers... 111 Pipe Rollers...111-112 Pipe Brackets... 113 Reference Tables...114-120

More information

2. Install two guide studs, J 36107, to the gear case. See Figure

2. Install two guide studs, J 36107, to the gear case. See Figure SERIES 60 SERVICE MANUAL 2. Install two guide studs, J 36107, to the gear case. See Figure 1-174. 1. Front Gear Case Cover 4. Locating Dowel (Round) 2. Front Engine Lift Bracket 5. Locating Dowel (Diamond)

More information

Spiderbeam Balun Construction Guide

Spiderbeam Balun Construction Guide BALUN CONSTRUCTION GUIDE Ver. 1.0 1 The components of the Balun Kit are in a plastic bag. Most of the components are inside the plastic case of the balun. The aluminum U-profile and the RG-142 Teflon Coax

More information

FAIRBANKS NIJHUIS 1590 SERIES SINGLE STAGE VERTICAL INLINE PUMP.

FAIRBANKS NIJHUIS 1590 SERIES SINGLE STAGE VERTICAL INLINE PUMP. FAIRBANKS NIJHUIS 0 SERIES SINGLE STAGE VERTICAL INLINE PUMP www.fairbanksnijhuis.com FAIRBANKS NIJHUIS 0 Series Single Stage Vertical Inline Pump Capacities to 00 GPM (,00 m/hr) Heads to 0 Feet ( m) Temperatures

More information

What is a fastener? A device to locate or hold parts

What is a fastener? A device to locate or hold parts What is a fastener? A device to locate or hold parts As a repair technician you will become skilled at removing, reconditioning, replacing, and installing fasteners. An important skill to learn is how

More information

.98M Ku-BAND Rx/Tx ANTENNA SYSTEM

.98M Ku-BAND Rx/Tx ANTENNA SYSTEM Revision C January 2, 2002 ASSEMBLY MANUAL ANTENNA SYSTEM PRODELIN CORPORATION 1500 Prodelin Drive Newton NC 28658 ANTENNA SYSTEM C Revised Series text B Revised Address 1/2/02 RAH A Revise and Update

More information

1.8 METER SERIES 1194 ANTENNA SYSTEM

1.8 METER SERIES 1194 ANTENNA SYSTEM January 14, 2002 REVISION G ASSEMBLY MANUAL 1.8 METER SERIES 1194 ANTENNA SYSTEM PRODELIN CORPORATION 1500 Prodelin Drive Newton NC 28658 1.8 METER SERIES 1194 ANTENNA SYSTEM G Revise Address 1/14/02 F

More information

FASTENERS, MEASUREMENTS AND CONVERSIONS

FASTENERS, MEASUREMENTS AND CONVERSIONS FASTENERS, MEASUREMENTS AND CONVERSIONS Bolts, Nuts and Other Threaded Retainers Although there are a great variety of fasteners found in the modern car or truck, the most commonly used retainer is the

More information

Beam and Purlin Clamps Beam Clamps

Beam and Purlin Clamps Beam Clamps Metal Framing & Cable Tray Steel City Hangers, Clamps & Fasteners Beam and Purlin Clamps Beam Clamps Fits beam flanges to 2" Supports 4" and 8" threaded rod, S-hooks, electrical boxes, conduit and bridle

More information

Riser Extension INSTALLATION GUIDE 40100AX35 / 40100AX18. Manual 40100X35-8

Riser Extension INSTALLATION GUIDE 40100AX35 / 40100AX18. Manual 40100X35-8 Riser Extension INSTALLATION GUIDE 40100AX35 / 40100AX18 Manual 40100X35-8 3 2 4 Access covers with bolts supplied with Interceptor 1 5 14 6 11 15 Sampling Port/Cleanout cap supplied with Interceptor 12

More information

MTS-ZB. RENOGY Photovoltaic Module Z-Bracket Mounting System E Philadelphia St, Ontario, CA Version: 1.

MTS-ZB. RENOGY Photovoltaic Module Z-Bracket Mounting System E Philadelphia St, Ontario, CA Version: 1. MTS-ZB RENOGY Photovoltaic Module Z-Bracket Mounting System 2775 E Philadelphia St, Ontario, CA 91761 1-800-330-8678 1 Version: 1.0 Important Safety Instructions Please save these instructions. This manual

More information

SAVVY OFF ROAD GAS TANK SKID INSTALLATION INSTRUCTIONS

SAVVY OFF ROAD GAS TANK SKID INSTALLATION INSTRUCTIONS It is best to work with a fuel tank that has the least amount of fuel in it as possible. Thank you for purchasing the best skid on the market. Please follow these instructions and your installation should

More information

IMPORTANT WARRANTY & INSTALLATION INSTRUCTIONS ATTACHED

IMPORTANT WARRANTY & INSTALLATION INSTRUCTIONS ATTACHED IMPORTANT WARRANTY & INSTALLATION INSTRUCTIONS ATTACHED Please Forward All Attached Information to Consumer Warranty Not Valid Unless Returned to Volant Performance STOP Please take time to read and understand

More information

Ave Edmonton, AB Canada T6P 0E2 Ph: Fax: apachepipe.com world class world wide

Ave Edmonton, AB Canada T6P 0E2 Ph: Fax: apachepipe.com world class world wide PIG OPTIONS 7-1 Model BB Flat Model BB Pencil Model RB 6-14 Flat Model RB 16-48 Flat Model HDPE 3-16 Pencil Model RB 16-48 Pencil 7-2 Model XB Pencil Model XB Flat Model XB Nylon Model XB Cantilever Assembly

More information

THIS SHOULD TWEAK YOUR IMAGINATION

THIS SHOULD TWEAK YOUR IMAGINATION 10-27-05 THIS SHOULD TWEAK YOUR IMAGINATION SPECIFICATIONS FOR SINGLE ANTENNA MODEL NUMBER... 432EME-12 FREQUENCY... 430-436 MHz GAIN... 14.4 dbd FRONT TO BACK... 23 db VSWR... 1.2:1 TYPICAL BEAMWIDTH...

More information

1.2M Ku-BAND Rx/Tx SERIES 1132 ANTENNA SYSTEM

1.2M Ku-BAND Rx/Tx SERIES 1132 ANTENNA SYSTEM August12, 2003 ASSEMBLY MANUAL Revision E 1.2M Ku-BAND Rx/Tx SERIES 1132 ANTENNA SYSTEM PRODELIN CORPORATION 1500 Prodelin Drive Newton NC 28658 1.2M Ku-BAND Rx/Tx SERIES 1132 ANTENNA SYSTEM E Revised

More information

1.2M Ku-BAND Rx/Tx SERIES 1134 ANTENNA SYSTEM

1.2M Ku-BAND Rx/Tx SERIES 1134 ANTENNA SYSTEM August 21, 1997 Revision D ASSEMBLY MANUAL 1.2M Ku-BAND Rx/Tx SERIES 1134 ANTENNA SYSTEM PRODELIN CORPORATION 1700 NE CABLE DRIVE CONOVER, NC 28613-0368 1.2M Ku-BAND Rx/Tx SERIES 1134 ANTENNA SYSTEM D

More information

Installation/Care/Use Manual Soft Sides Freeze Resistant Fountain

Installation/Care/Use Manual Soft Sides Freeze Resistant Fountain Installation/Care/Use Manual Soft Sides Freeze Resistant Fountain EDFP217FPC Installer To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION.

More information

Support@Powrkraft.com 8ga. @ 0ft, 6ga. @ 50ft, ga @ 00ft, 0ga @ 00ft 3-6 Model Number Motor Diameter* 65556 500W 0 Volt 0 / Most Wood 0 4 ton 30 PSI 3.7 qt. 37 0 97 lb. 6 0W (-3 ISO Viscosity) Hydraulic

More information

STANDARD "T" HANDLE CLAMPS

STANDARD T HANDLE CLAMPS STANDARD "T" HANDLE CLAMPS Standard "T" Handles 401 1" 405 2" 410 3" 420 6" 430 9" 440 12" Multi-purpose clamps combine the best features of ordinary "C" and parallel clamps. Free-floating jaws adjust

More information

PROFESSIONAL FLARING TOOL 001ERL 37 & ERL 37

PROFESSIONAL FLARING TOOL 001ERL 37 & ERL 37 PROFESSIONAL FLARING TOOL 001ERL 37 & 45 002ERL 37 001ERL shown here OWNER S MANUAL 199R11215 EDUCATIONAL TIPS Make sure the end of the tube is cut off square. Before flaring, make sure the die clamp is

More information

TEL:1-866-XANATOS INSTALLATION INSTRUCTIONS GRILL GUARD FOR FORD EXPLORER PART # 17FJ26MA

TEL:1-866-XANATOS INSTALLATION INSTRUCTIONS GRILL GUARD FOR FORD EXPLORER PART # 17FJ26MA \ TEL:1-866-XANATOS INSTALLATION INSTRUCTIONS GRILL GUARD FOR FORD EXPLORER 02-05 PART # 17FJ26MA NOTE: Please read this information before assembling. Complete step by step instruction sheets will be

More information

Joint Restraints/ Bell & Spigot Joint/ New & In-Service Installations (2" IPS PVC Pipe)

Joint Restraints/ Bell & Spigot Joint/ New & In-Service Installations (2 IPS PVC Pipe) C 1 C 1.1 Joint Restraints/ Bell & Spigot Joint/ New & In-Service Installations (2" IPS PVC Pipe) Joint Restraints/ Bell & Spigot Joint/ New & In-Service Installations (AWWA C-900 PVC Pipe) C 1.1.1 Joint

More information

Directive Systems & Engineering 2702 Rodgers Terrace Haymarket, VA

Directive Systems & Engineering 2702 Rodgers Terrace Haymarket, VA Directive Systems & Engineering 2702 Rodgers Terrace Haymarket, VA 20169 1628 www.directivesystems.com 703 754 3876 K1JX DESIGNED 6 ELEMENT 50 MHZ YAGI, DSEJX6 50 INTRODUCTION The Directive Systems DSEJX6-50

More information

COYOTE. Product Guide VOLUME 1

COYOTE. Product Guide VOLUME 1 COYOTE Product Guide VOLUME 1 CYLINDER HEAD STUD KITS The key to optimum combustion chamber sealing and long-term reliability, ARP head studs are the ideal replacement for factory TTY (Torque To Yield)

More information

Tuf-Lite III Fans 5000K Series Hub

Tuf-Lite III Fans 5000K Series Hub Tuf-Lite III Fans 5000K Series Hub INSTALLATION MANUAL Hudson Tuf-Lite III fan blades Adjustable Pitch Fan Assembly 20 thru 30 Diameter Hudson Tuf-Lite III fan blades are of single piece fiberglass reinforced

More information

Clamps. Preformed Clamping Systems. Clamps. Band-It. Band-It

Clamps. Preformed Clamping Systems. Clamps. Band-It. Band-It Preformed Clamping Systems As industrial hose made of stiffer, thinner, thermoplastics replace soft, spongy, thickwalled rubber, a new generation of hose clamps has been developed to prevent leak problems.

More information

Superstrut Stainless Steel Channels and Accessories

Superstrut Stainless Steel Channels and Accessories In this section... Superstrut Stainless Steel Channels and Accessories Superstrut Stainless Steel Channels and Accessories Channels...46 Channel Fittings and Hardware...47 49 Clamps and Hangers...50 52

More information

Ford Couplings For Pipe And Tubing

Ford Couplings For Pipe And Tubing Section J 6/2002 Ford Couplings For Pipe And Tubing The Ford Meter Box Co., Inc. 775 Manchester Avenue, P.O. Box 443, Wabash, Indiana, USA 46992-0443 Telephone: 260/563-3171 FAX: 1-800-826-3487 Overseas

More information