More Complete Protection

Size: px
Start display at page:

Download "More Complete Protection"

Transcription

1 More Complete Protection AFCI, GFCI and Dual Function AFCI/GFCI Receptacles and Circuit Breakers THE FUTURE IS ON

2 GFCI Protection Leviton is the world s leading manufacturer of residential and commercial GFCI Receptacles. Building upon this success, we have channeled our patented technology into the development of GFCI Circuit Breakers; resulting in two industry-leading solutions to help protect against shock or electrocution. Both feature our patented reset/lockout functionality and prevent reset of the device if it is not wired or operating correctly. GFCI Receptacles - Self-testing and exceed UL requirements for ground-fault protection - Detects and trips on actual ground-faults even when self-test is being conducted - Tests the GFCI within 3 seconds upon initial power-up - Auto-monitoring exceeds UL requirements - Auto adapts/shifts to more frequent testing if potential problem is detected - LED indicator light on the device face provides simple, intuitive feedback on power and protection status and indicates line/load reversal for at-a-glance analysis - Superior resistance to electrical surges and over-voltages - Available in Guide Light, Combination with Switch, Combination with Guide Light, Audible Trip Alert, Blank Face, Hospital Grade and Weather-Resistant models to satisfy all residential and commercial applications GFTR1 GFTR2 GFNL1 GFSW1 Tamper-Resistant Duplex GFCI Receptacle with LED Indicator Tamper-Resistant Duplex GFCI Receptacle with LED Indicator Receptacle, 20A-125V Feed-Through NEMA 5-20R Tamper-Resistant Duplex Guide Light GFCI Receptacle with LED Indicator Tamper-Resistant Combination Switch with LED Indicator 120 VAC Switch rating Available in: White, Ivory, Light Almond, and select models in Gray, Black, Brown. GFCI Circuit Breakers - Patented SmartlockPro reset/lockout feature prevents reset of the device if for any reason it is unable to respond to a ground-fault - LED indicator light incorporated into each individual circuit breaker allows users to easily identify trip condition - Line-side power ensures that the LED remains lit, even when a circuit breaker has tripped - Color indicators in the handle make it easy to see operational status at-a-glance LB115-GF LB120-GF LB125-GF LB130-GF LB240-GF LB250-GF LB260-GF 1-Pole GFCI Circuit Breaker with LED Indicator, 15A 1-Pole GFCI Circuit Breaker with LED Indicator, 20A 1-Pole GFCI Circuit Breaker with LED Indicator, 25A 1-Pole GFCI Circuit Breaker with LED Indicator, 30A 2-Pole GFCI Circuit Breaker with LED Indicator, 40A 2-Pole GFCI Circuit Breaker with LED Indicator, 50A 2-Pole GFCI Circuit Breaker with LED Indicator, 60A

3 Dual Function AFCI/GFCI Protection Arc-faults and ground-faults are dangerous conditions that could lead to electrical fires or electrical shock. SmartlockPro Dual Function AFCI/GFCI Receptacles and Dual Function AFCI/GFCI Circuit Breakers help to create a safer living environment by offering complete protection in one smart device. If either fault is detected, the device quickly interrupts power to help avoid a potential fire or shock occurrence. Dual Function AFCI/GFCI Receptacles SmartlockPro Dual Function AFCI/GFCI Receptacles offer a National Electrical Code (NEC ) compliant option for AFCI/GFCI protection in residential kitchens and laundry areas for new construction, modifications/extensions and replacement receptacles. - LED indicator light on the device face provides simple, intuitive feedback on power and protection status, gives a clear indication of the type of fault detected, and indicates line/load reversal for at-a-glance analysis - May be used as a replacement for ungrounded receptacles, satisfying NEC requirements for both AFCI and GFCI protection AGTR1 AGTR2 Dual Function AFCI/GFCI Receptacle with LED Indicator Receptacle 20A-125V Feed-Through Dual Function AFCI/GFCI Receptacle with LED Indicator Receptacle 20A-125V Feed-Through Available in: White, Ivory, Light Almond, Gray, Black, Brown. Dual Function AFCI/GFCI Circuit Breakers Leviton Dual Function AFCI/GFCI Circuit Breakers provide arc-fault and ground-fault protection as well as overload and short circuit protection. They are ideal for kitchen and laundry room applications. - Patented SmartlockPro reset/lockout feature prevents reset of the device if for any reason it is unable to respond to an arc-fault or ground-fault - LED indicator lights incorporated into each individual circuit breaker allows users to easily identify the trip condition and type of fault (AF/GF); if arc-fault, a visual indicator differentiates between parallel and series - Line-side power ensures that the LEDs remain lit, even when a circuit breaker has tripped - Color indicators in the handle make it easy to see operational status at-a-glance LB115-DF LB120-DF 1-Pole Dual Function AFCI/GFCI Circuit Breaker with LED Indicator Light, 15A 1-Pole Dual Function AFCI/GFCI Circuit Breaker with LED Indicator Light, 20A

4 AFCI Protection Leviton AFCI Receptacles and AFCI Circuit Breakers help protect against electrical fires resulting from arc-faults. They feature our patented reset/lockout functionality and will not reset if arc-fault protection is compromised, offering more complete protection. AFCI Receptacles - LED indicator light on the device face provides simple, intuitive feedback on power and protection status and indicates line/load reversal for at-a-glance analysis AFTR1 AFTR2 AFRBF AFSW1 Tamper-Resistant Outlet Branch Circuit AFCI Receptacle with LED Indicator Tamper-Resistant Outlet Branch Circuit AFCI Receptacle with LED Indicator Receptacle, 20A-125V Feed-Through NEMA 5-20R Blank Face Outlet Branch Circuit AFCI Receptacle with LED Indicator 20A-125V Feed-Through Outlet Branch Circuit Combination AFCI/Switch with LED Indicator 15A-120V Switch Available in: White, Ivory, Light Almond, and select models in Gray, Black, Brown. AFCI Circuit Breakers - Patented SmartlockPro reset/lockout feature prevents reset of the device if for any reason it is unable to respond to an arc-fault - LED indicator light incorporated into each individual circuit breaker allows users to easily identify the trip condition and type of fault, parallel or series - Line-side power ensures that the LED remains lit, even when a circuit breaker has tripped - Color indicators in the handle make it easy to see operational status at-a-glance LB115-AF LB120-AF 1-Pole AFCI Circuit Breaker with LED Indicator, 15A 1-Pole AFCI Circuit Breaker with LED Indicator, 20A

5 As a recognized leader in electrical safety and innovation, Leviton offers the most advanced safety technology to assure the homes you build are Code compliant and provide the highest degree of protection against electrical fire and shock for the families who live there. Leviton Arc-Fault Circuit Interrupter (AFCI), Ground-Fault Circuit Interrupter (GFCI) and Dual Function AFCI/GFCI Receptacles and Circuit Breakers are engineered to the highest standards so you can feel confident with every installation. Electrical safety is serious business. Put your trust in the company that is serious about electrical safety Leviton. Leviton Offers More Complete Protection Patented Reset Lockout As an additional safeguard, all Leviton AFCI, GFCI and AFCI/GFCI devices feature a reset/lockout function which prevents the device from being reset if any of the following conditions exist: - GFCI or AFCI is not functioning properly - GFCI or AFCI protection has been compromised - Line and load wires were reversed during installation GFCI Self-Test Engineered to meet the latest UL standard for auto-monitoring (self-test), all Leviton receptacles and circuit breakers with GFCI technology periodically conduct an automatic internal test to confirm that GFCI protected power is present. - Provides continuous ground-fault protection detects and trips on an actual ground-fault even when self-test is being conducted - On initial power up, tests the GFCI within 3 seconds - Auto adapts and shifts to more frequent testing if potential problem is detected - Testing frequency regularly updates protection status

6 Leviton Manufacturing Co., Inc. 201 North Service Road, Melville, NY Telephone: FAX: Tech Line: Mon-Fri 8am-10pm EST, Saturday 9am-7pm EST Visit our Website at: Leviton Manufacturing Co., Inc. All rights reserved. All trademarks are the property of their respective owners. G-10157/K17-dp

Recp/Nightlight Combo 15A 125V TR, Iv

Recp/Nightlight Combo 15A 125V TR, Iv 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 TR7735VB0X Recp/Nightlight Combo 15A 125V TR, Iv Eaton Wiring Devices Catalog Number Manufacturer Description Weight per

More information

The most complete line to protect young children.

The most complete line to protect young children. P&S Tamper-Resistant Receptacles The most complete line to protect young children. Meets National Electrical Code Requirements designed to be better. P&S Tamper-Resistant Receptacles the full line to meet

More information

High-impact resistant thermoplastic construction

High-impact resistant thermoplastic construction Residential Grade Devices Receptacles TradeMaster Receptacles Tamper-Resistant Receptacles High-impact resistant thermoplastic construction Extra-long strap, Quickloop wire looping aid Long-term blade

More information

G.F.C.I. by Sam Goldwasser -- exerpts from: Sci.Electronics.Repair FAQ:

G.F.C.I. by Sam Goldwasser -- exerpts from: Sci.Electronics.Repair FAQ: 1 of 6 8/4/2007 6:52 PM This page is from the original Code Check website. To see the latest version choose "Home Page New" Code Check 1998 by Redwood Kardon Home Page New Search What is a GFCI?: G.F.C.I.

More information

National Marine Manufacturers Association Compliance Specialist Examination A.C. Electrical (2018 Model Year) ABYC E-11 Supplement 56

National Marine Manufacturers Association Compliance Specialist Examination A.C. Electrical (2018 Model Year) ABYC E-11 Supplement 56 1. Two Electrical Technicians are discussing markings that are required for AC wiring. Tech A says that AC conductors must be rated for 600 volts and must have their jackets and individual conductors marked

More information

Electrical requirements for plans on all new homes, additions, remodels & Service upgrades

Electrical requirements for plans on all new homes, additions, remodels & Service upgrades CHERRY HILLS VILLAGE COLORADO Electrical requirements for plans on all new homes, additions, remodels & Service upgrades Due to the size and uniqueness of homes built in Cherry Hills Village, a policy

More information

User's Guide. AC Circuit Load Tester. Model CT70

User's Guide. AC Circuit Load Tester. Model CT70 User's Guide AC Circuit Load Tester Model CT70 Introduction Congratulations on your purchase of the CT70 AC Circuit Load Tester. This device can detect circuit and wiring problems such as: Poor ground

More information

Alternating Current Power

Alternating Current Power Chapter 4 Alternating Current Power MElec-Ch4-1 Overview What is Alternating Current AC Hazards AC Power Requirements Shoreside Utility System On-Board Generators MElec-Ch4-2 What is Alternating Current

More information

Gen Purpose Wiring Devices - Gen Purpose Recept & Surge Prot

Gen Purpose Wiring Devices - Gen Purpose Recept & Surge Prot 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 VGFD20A 20A Alm Gfci RCPT Eaton Wiring Devices Catalog Number VGFD20A Manufacturer Eaton Wiring Devices Description Circuit

More information

Home Electrical Wiring. Types of Receptacles and Wiring them for 120v 15Amp/20Amp

Home Electrical Wiring. Types of Receptacles and Wiring them for 120v 15Amp/20Amp Home Electrical Wiring Types of Receptacles and Wiring them for 120v 15Amp/20Amp Understanding the wires You have 3 wires in a home electrical system; Hot (Black wire) - dangerous one Neutral (White wire)

More information

PlugTail the most complete line of labor-saving electrical wiring devices.

PlugTail the most complete line of labor-saving electrical wiring devices. PlugTail the most complete line of labor-saving electrical wiring devices. :05 sec. :15 sec. :37 sec. 1 2 Scan this code and find the right PlugTail solution to your market challenge. 3 4 5 6 PlugTail

More information

120-WATT POWER PACK MODEL #00688

120-WATT POWER PACK MODEL #00688 PORTFOLIO and PORTFOLIO & Design are trademarks or registered trademark of LF, LLC. ll rights reserved. ITEM #08086 20-WTT POWER PCK MODEL #00688 Español p. 9 TTCH YOUR RECEIPT HERE Serial Number Purchase

More information

Healthcare Isolation Power Systems. Presented by: David Knecht

Healthcare Isolation Power Systems. Presented by: David Knecht Healthcare Isolation Power Systems Presented by: David Knecht E-Mail: David.Knecht@Bender-us.com Healthcare Isolation Power Systems Theory Offer Codes & Standards FAQs Isolated Power System Purpose To

More information

GROUNDED ELECTRICAL POWER DISTRIBUTION. Excerpt from Inverter Charger Series Manual BY: VIJAY SHARMA ENGINEER

GROUNDED ELECTRICAL POWER DISTRIBUTION. Excerpt from Inverter Charger Series Manual BY: VIJAY SHARMA ENGINEER GROUNDED ELECTRICAL POWER DISTRIBUTION Excerpt from Inverter Charger Series Manual BY: VIJAY SHARMA ENGINEER .0 Conductors for Electrical Power Distribution For single-phase transmission of AC power or

More information

High Performance Nylon Wallplates. Nylon Wallplates

High Performance Nylon Wallplates. Nylon Wallplates Commercial Grade IVORY 80701-I N1-I BLACK 80701-E N1-BK GRAY 80701-GY N1-GRY RED 80701-R N1-RED WHITE 80701-W N1-W BROWN 80701 N1 1-Toggle ALMOND 80701-A N1-A IVORY 80709-I N2-I BLACK 80709-E N2-BK GRAY

More information

Vizia + Commercial Grade Lighting Controls Collection

Vizia + Commercial Grade Lighting Controls Collection G-7882B Vizia Family Spec Sht.qxd:Layout 1 12/1/09 9:06 AM Page 1 PRODUCT SPECIFICATIONS VPT24-1P VPI06-1L VPM10-1L VPE06-1L VPS15 KEY PRODUCT FEATURES Superior versatility provides six product options

More information

Page 1 T O O L S A N D M AT E R I A L S R E Q U I R E D. 1. Screwdriver 2. Carpenter's level 3. Electrical Tape PA R T S L I S T. A.

Page 1 T O O L S A N D M AT E R I A L S R E Q U I R E D. 1. Screwdriver 2. Carpenter's level 3. Electrical Tape PA R T S L I S T. A. T O O L S A N D M AT E R I A L S R E Q U I R E D 1. Screwdriver 2. Carpenter's level 3. Electrical Tape PA R T S L I S T A. Cabinet B. Wood Screw X4 C. Plastic wire connector x3 Page 1 I M P O R TA N T

More information

(51) Int. Cl... HoH 316 trolling a state of conduction of AC current between the

(51) Int. Cl... HoH 316 trolling a state of conduction of AC current between the USOO58599A United States Patent (19) 11 Patent Number: 5,8,599 ROSenbaum () Date of Patent: Oct. 20, 1998 54 GROUND FAULT CIRCUIT INTERRUPTER 57 ABSTRACT SYSTEM WITH UNCOMMITTED CONTACTS A ground fault

More information

Numbering System for Protective Devices, Control and Indication Devices for Power Systems

Numbering System for Protective Devices, Control and Indication Devices for Power Systems Appendix C Numbering System for Protective Devices, Control and Indication Devices for Power Systems C.1 APPLICATION OF PROTECTIVE RELAYS, CONTROL AND ALARM DEVICES FOR POWER SYSTEM CIRCUITS The requirements

More information

SE-502 MANUAL GROUND-FAULT GROUND-CONTINUITY DETECTOR

SE-502 MANUAL GROUND-FAULT GROUND-CONTINUITY DETECTOR SE-502 MANUAL GROUND-FAULT GROUND-CONTINUITY DETECTOR March 5, 2002 PRELIMINARY 1 Publication: SE-502-M Document: S95-C502-00000 Printed in Canada. Copyright 2002 by Startco Engineering Ltd. All rights

More information

TEACHER ASSESSMENT BLUEPRINT ELECTRICAL CONSTRUCTION TECHNOLOGY. Test Code: 5171 Version: 01

TEACHER ASSESSMENT BLUEPRINT ELECTRICAL CONSTRUCTION TECHNOLOGY. Test Code: 5171 Version: 01 TEACHER ASSESSMENT BLUEPRINT ELECTRICAL CONSTRUCTION TECHNOLOGY Test Code: 5171 Version: 01 Specific Competencies and Skills Tested in this Assessment: OSHA Regulations and Electrical Safety Practices

More information

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING 1.0 General This specification covers the electrical characteristics and general

More information

2.2 American National Standards Institute Corporation and its applicable standards C39.1, C80.1, C89, C84.1.

2.2 American National Standards Institute Corporation and its applicable standards C39.1, C80.1, C89, C84.1. TECHNICAL SPECIFICATIONS for Single Phase, 1 to 3 KVA Power Conditioner with Regulation and Distribution Constant Power 3 (CP3) CP36508A 7/15/04 1.0 General This specification covers the electrical characteristics

More information

Hexa Multi Module 366HMM. Introduction. Design Specifications. Key Features

Hexa Multi Module 366HMM. Introduction. Design Specifications. Key Features Hexa Multi Module Introduction The E-Plex 366HMM is a six channel DC power distribution module capable of handling loads of up to 15A per channel or 50A total. The six channels can be utilized as either

More information

SureTest Circuit Analyzers

SureTest Circuit Analyzers Circuit Analyzers SureTest Circuit Analyzers Measures voltage drop under load* Hot and neutral conductor impedances Estimates Load on Line (ELL) up to 15A Tests GFCIs and EPDs for proper operation Super-bright

More information

THMS WATT WATT PEAK Other Models

THMS WATT WATT PEAK Other Models DC-AC Power Inverter Modified Sine Wave 1000 Watts & Up Worktruck Power Inverters THMS Series THOR Manufacturing Modified Sine Wave inverters have set the standard with the way you deal with your mobile

More information

a) Determine the smallest, standard-sized circuit breaker that should be used to protect this branch circuit.

a) Determine the smallest, standard-sized circuit breaker that should be used to protect this branch circuit. ECET4520 Exam II Sample Exam Problems Instructions: This exam is closed book, except for the reference booklet provided by your instructor and one (8.5 x11 ) sheet of handwritten notes that may not contain

More information

BECAUSE MOTOR & GENERATOR FAILURE IS NOT AN OPTION USCG

BECAUSE MOTOR & GENERATOR FAILURE IS NOT AN OPTION USCG PRODUCT CATALOG M O T O R & G E N E R A T O R P R O T E C T I O N BECAUSE MOTOR & GENERATOR FAILURE IS NOT AN OPTION USCG Why Your Equipment Needs MEG-ALERT Protection 1 2 3 4 5 6 7 How can you be sure

More information

The Mural Collection II. Advanced All-Digital Decora-Style Dimmers with Preset and Scene Capable Models

The Mural Collection II. Advanced All-Digital Decora-Style Dimmers with Preset and Scene Capable Models The Mural Collection II Advanced All-Digital Decora-Style Dimmers with Preset and Scene Capable Models The Mural Collection II Setting The Mood of The New Millennium Lighting Control with Style. Three

More information

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL series

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL series IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL 61-160 series The Service Information provides the following information Precautions and safety information Specifications Performance test procedure Calibration

More information

Michigan State University Construction Standards WIRING DEVICES PAGE

Michigan State University Construction Standards WIRING DEVICES PAGE PAGE 262726-1 SECTION 262726 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

NEC 2014 Code Changes

NEC 2014 Code Changes NEC 2014 Code Changes Articles 200-215.3 CHANGES FROM 2011 CODE ARE IN RED Chapter 2 - Wiring and Protection ARTICLE 200 Use and Identification of Grounded Conductors 200.2 General Grounded Conductors

More information

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions conduit? 9/8/10 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. Can branch circuits of different services be installed in the same Yes, see 300.3(C)(1) for conductors of different systems

More information

Pure Sine Wave Inverter Driver Board Egs002 Eg8010 Ir2110

Pure Sine Wave Inverter Driver Board Egs002 Eg8010 Ir2110 Pure Sine Wave Inverter Driver Board Egs002 Eg8010 Ir2110 PURE SINE WAVE INVERTER DRIVER BOARD EGS002 EG8010 IR2110 PDF - Are you looking for pure sine wave inverter driver board egs002 eg8010 ir2110 Books?

More information

PLUG LOAD CONTROL SOLUTIONS PASS & SEYMOUR DEVICES THAT MAKE ENERGY MANAGEMENT AUTOMATIC

PLUG LOAD CONTROL SOLUTIONS PASS & SEYMOUR DEVICES THAT MAKE ENERGY MANAGEMENT AUTOMATIC PASS & SEYMOUR PLUG LOAD CONTROL SOLUTIONS DEVICES THAT MAKE ENERGY MANAGEMENT AUTOMATIC CONTROL THAT S CONVENIENT, CONNECTED AND CODE-COMPLIANT. New requirements for reducing energy consumption in commercial

More information

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. I have a 500 KVA generator, with no overcurrent protection

More information

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations Connecting the Power of the Sun DC Disconnects for Solar Photovoltaic Installations DC disconnects for solar photovoltaic installations Solar energy is heating up Interest in renewable energy sources has

More information

Frequently Asked Question on Isolated Power Supply(IPS)

Frequently Asked Question on Isolated Power Supply(IPS) Frequently Asked Question on Isolated Power Supply(IPS) Q: What is an IPS? A: IPS is called as Isolated Power Supply or System and is used in a Hospital to ensure safe power supply to OT Operation Theaters

More information

SureTest Model ST-1THD & ST-1THDC Instructions

SureTest Model ST-1THD & ST-1THDC Instructions #61-156 #61-157 #61-158 SureTest Model ST-1THD & ST-1THDC Instructions Introduction The SureTest family of Circuit/distortion analyzers identify problems common to electrical circuits and harmonic distortion

More information

Unit 3 Magnetism...21 Introduction The Natural Magnet Magnetic Polarities Magnetic Compass...21

Unit 3 Magnetism...21 Introduction The Natural Magnet Magnetic Polarities Magnetic Compass...21 Chapter 1 Electrical Fundamentals Unit 1 Matter...3 Introduction...3 1.1 Matter...3 1.2 Atomic Theory...3 1.3 Law of Electrical Charges...4 1.4 Law of Atomic Charges...4 Negative Atomic Charge...4 Positive

More information

Preface...x Chapter 1 Electrical Fundamentals

Preface...x Chapter 1 Electrical Fundamentals Preface...x Chapter 1 Electrical Fundamentals Unit 1 Matter...3 Introduction...3 1.1 Matter...3 1.2 Atomic Theory...3 1.3 Law of Electrical Charges...4 1.4 Law of Atomic Charges...5 Negative Atomic Charge...5

More information

SECTION PANELBOARDS

SECTION PANELBOARDS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 24 16 PANELBOARDS SPEC WRITER NOTE: Delete between // --- // if not applicable to project. Also, delete any other item or paragraph not applicable in the section

More information

Plug-In Circuit Breakers

Plug-In Circuit Breakers Plug-In Circuit Breakers Types QP, QPH, and HQP with INSTA-WIRE, QN and QNH 14 1-POLE (120V AC) 10 MP110 15 MP115 MP115KH MP115KM 20 MP120 MP120KH MP120KM 25 MP125 MP125KH MP125KM 30 MP130 MP130KH MP130KM

More information

(10. (12) United States Patent US 6,633,467 B2. Oct. 14, (45) Date of Patent: (10) Patent No.: to To ARC DETECTOR/ (54)

(10. (12) United States Patent US 6,633,467 B2. Oct. 14, (45) Date of Patent: (10) Patent No.: to To ARC DETECTOR/ (54) (12) United States Patent Macbeth et al. USOO6633467B2 (10) Patent No.: (45) Date of Patent: US 6,633,467 B2 Oct. 14, 2003 (54) (75) (73) (*) (21) (22) (65) (60) (51) (52) (58) AFC WHICH DETECTS AND INTERRUPTS

More information

EELE 354 Lab Assignment 5: Fuse and Ground Fault Current Interrupter (GFCI) Operation

EELE 354 Lab Assignment 5: Fuse and Ground Fault Current Interrupter (GFCI) Operation EELE 354 Lab Assignment 5: Fuse and Ground Fault Current Interrupter (GFCI) Operation EELE 354 Lab Assignment 5 1 Lab Overview: In electrical circuits, it is often necessary (either through code or just

More information

1. Executive Summary. 2. Introduction. Selection of a DC Solar PV Arc Fault Detector

1. Executive Summary. 2. Introduction. Selection of a DC Solar PV Arc Fault Detector Selection of a DC Solar PV Arc Fault Detector John Kluza Solar Market Strategic Manager, Sensata Technologies jkluza@sensata.com; +1-508-236-1947 1. Executive Summary Arc fault current interruption (AFCI)

More information

2011 / Circuit Tracer

2011 / Circuit Tracer INSTRUCTION MANUAL 2011 / 00521 Circuit Tracer Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. 52044992 2008 Greenlee Textron

More information

Ground Fault Isolation with Loads Fed from Separately Derived Grounded Sources

Ground Fault Isolation with Loads Fed from Separately Derived Grounded Sources Ground Fault Isolation with Loads Fed from Separately Derived Grounded Sources Introduction Ground fault sensing detects current that flows between a source and a (faulted) load traveling on other than

More information

Ham Radio Safety In & Out Of The Shack

Ham Radio Safety In & Out Of The Shack Ham Radio Safety In & Out Of The Shack Areas of Discussion Electrical Safety AC Power Grounding Antenna Safety Mobile Installations Electrical Safety AC Safety Grounding Most ham stations DO NOT require

More information

AU INSTALLATION INSTRUCTIONS. Revision B1 Rapid City, SD, USA, 02/2010 II_201A-AU_B1

AU INSTALLATION INSTRUCTIONS. Revision B1 Rapid City, SD, USA, 02/2010 II_201A-AU_B1 INSTALLATION INSTRUCTIONS Revision B1 Rapid City, SD, USA, 02/2010 MODELS 201A-AU 201-575-AU II_201A-AU_B1 2880 North Plaza Drive, Rapid City, South Dakota 57702 (800) 843-8848 (605) 348-5580 fax (605)

More information

Multi-level Arc Fault Circuit Interrupter with Collaborative Communications for Smart Grid

Multi-level Arc Fault Circuit Interrupter with Collaborative Communications for Smart Grid Multi-level Arc Fault Circuit Interrupter with Collaborative Communications for Smart Grid HyungSeok Kim, SeongWoo Kim, GiPoong Gwon, DongRyul Lee, and SeungWoo Seo Department of Electrical Engineering

More information

SERVO CONTROLLER. Sdtork Introduce Digital Servo Controller with several Features for all type of Valve Automation.

SERVO CONTROLLER. Sdtork Introduce Digital Servo Controller with several Features for all type of Valve Automation. SERVO CONTROLLER INTRODUCTION: Sdtork Introduce Digital Servo Controller with several Features for all type of Valve Automation. AIM: Sdtorks main aim is to make automation in all industries so here we

More information

Straight Isolation - Plug In (171 Series)

Straight Isolation - Plug In (171 Series) Straight Isolation - Plug In (171 Series) LINE ISOLATION PLUG & RECEPTACLE TRANSFORMERS (115V to 115V) Primary 115C, 50/60 Hz., Secondary 115C Electrostatic shield between primary & secondary. Hi-pot tested

More information

Dual Reversing Module

Dual Reversing Module Dual Reversing Module Introduction The E-Plex 425DRM has been designed to simplify wiring in electronic systems by providing the reversing function local to the motor devices thus eliminating long cable

More information

BC145 SIGNAL ISOLATOR BOARD

BC145 SIGNAL ISOLATOR BOARD BC145 SIGNAL ISOLATOR BOARD 4/17 Installation & Operating Manual MN1373 Any trademarks used in this manual are the property of their respective owners. Important: Be sure to check www.baldor.com to download

More information

Grounding and Bonding

Grounding and Bonding Grounding and Bonding 2017 Communications Academy Joe Blaschka Jr., PE Grounding/Bonding What is it? Why do we do it? What does the National Electrical Code say? What about fixed locations? What about

More information

Utility Systems Technologies, Inc. Sag Fighter. Deep Voltage Sag Protection:

Utility Systems Technologies, Inc. Sag Fighter. Deep Voltage Sag Protection: Utility Systems Technologies, Inc. Sag Fighter TM Deep Voltage Sag Protection: D e e p Vo l t a g e S a g P r o t e c t i o n For three phase application: Q u a l i t y P o w e r. B e t t e r B u s i n

More information

120 / 240 VAC SINGLE SPLIT PHASE & MULTI-WIRE BRANCH CIRCUITS. Excerpt from G4 InverCharge Series Manual BY: VIJAY SHARMA ENGINEER

120 / 240 VAC SINGLE SPLIT PHASE & MULTI-WIRE BRANCH CIRCUITS. Excerpt from G4 InverCharge Series Manual BY: VIJAY SHARMA ENGINEER 120 / 240 VC SILE SPLIT PHSE & MULTI-WIRE RCH CIRCUITS Excerpt from 4 InverCharge Series Manual Y: VIJY SHRM EIEER 120 / 240 VC SILE SPLIT PHSE & MULTI-WIRE RCH CIRCUITS i IFO For purposes of explaining

More information

Power-Sure 700. Technical Data TD158001EN. Contents

Power-Sure 700. Technical Data TD158001EN. Contents Technical Data TD158001EN Power-Sure 700 Supersedes August 2015 Contents Description Page General description... 2 Power-Sure 700 benefits.... 2 Specifications... 3 Industry standards and certifications...

More information

Circuit Drawings and Wiring Diagrams

Circuit Drawings and Wiring Diagrams Youth Explore Trades Skills Description Successfully performing electrical work requires the ability to read and interpret many different types of drawings and diagrams. Understanding circuit symbols and

More information

LIGHT ARC DETECTOR Type LAD

LIGHT ARC DETECTOR Type LAD APPLICATIONS Prevent internal arc in MV HV switchgear or transformers Selective fault detection for fast plant recovery HIGHLIGHTS Remote indication by change-over contact for fault condition Local fault

More information

Distributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. LM1851 Ground Fault Interrupter General Description The LM1851 is designed

More information

FLOOR BOXES AND COVERS

FLOOR BOXES AND COVERS FLOOR BOXES AND COVERS ENERLTES floor boxes are an ideal solution for bringing power and communication into commercial and residential buildings. Designed with a rugged cover that protects the box from

More information

DC PV Arc fault detection Unit

DC PV Arc fault detection Unit DC PV Arc fault detection Unit Installation, usage and other information Author: Peter v. Galen, Product Manager Date: 15-09-2014 Revision: B 1. Introduction The National Electrical Code 2011 states arc-fault

More information

Operation Manual. Congratulations on purchasing your high quality AIMS Power pure sine inverter!

Operation Manual. Congratulations on purchasing your high quality AIMS Power pure sine inverter! Operation Manual Congratulations on purchasing your high quality AIMS Power pure sine inverter! It is very important that you read and understand this instruction manual completely prior to use. Contained

More information

Straight Blade Receptacles

Straight Blade Receptacles Straight Blade eceptacles Table of Contents A SECTION Page Straight Blade Specifier s Chart A-1 Modular Connectors A-2 Build-To-Spec A-4 Hospital Grade eceptacles A-5 2-Pole, 3-Wire 15A, 125V/AC...............

More information

PSOL. Remove mounting screws. Remove ears. Add 6" leads PSOL = #12 AWG solid PSTR = #12 AWG stranded

PSOL. Remove mounting screws. Remove ears. Add 6 leads PSOL = #12 AWG solid PSTR = #12 AWG stranded Switch Options Work Smarter Not Harder Arrow Hart custom configured wiring devices can match any of your complex industrial or commercial job needs, simplifying your project and maximizing your bottom

More information

Electrical Construction Technology

Electrical Construction Technology Measuring What Matters in Job Ready Assessment Blueprint Electrical Construction Technology Test Code: 4130 / Version: 01 Copyright 2011 General Assessment Information Electrical Construction Technology

More information

Keyed latch. Cover. Service Outlet 115VAC, 15A. Plastic base. Unpack. Operator. the Operator

Keyed latch. Cover. Service Outlet 115VAC, 15A. Plastic base. Unpack. Operator. the Operator Service Outlet Quick Start Steps Keyed latch Cover 115VAC, 15A Plastic base Operator Unpack the Operator Site Planning and Operator Installation The illustrations and instructions presented in this guide

More information

Grounding Recommendations for On Site Power Systems

Grounding Recommendations for On Site Power Systems Grounding Recommendations for On Site Power Systems Revised: February 23, 2017 2017 Cummins All Rights Reserved Course Objectives Participants will be able to: Explain grounding best practices and code

More information

THEATRICAL LIGHTING SOLUTION PACKAGE Complete, versatile and cost effective

THEATRICAL LIGHTING SOLUTION PACKAGE Complete, versatile and cost effective THEATRICAL LIGHTING SOLUTION PACKAGE Complete, versatile and cost effective Stage Lighting Package Guide 400-900 Seat As would typically be found in schools where theatrical production capability was desired

More information

PACSystems* RX3i IC695MDL765

PACSystems* RX3i IC695MDL765 March 2011 PACSystems* RX3i IC695MDL765 Digital Output Module with Diagnostics 16-Channel The 24/125 volt DC 2A Smart Digital Output module, IC695MDL765, provides 16 discrete outputs in two isolated groups

More information

SA-150, SA-300 Series Pure Sine Wave Inverter User s Manual

SA-150, SA-300 Series Pure Sine Wave Inverter User s Manual SA-150, SA-300 Series Pure Sine Wave Inverter User s Manual List of contents 1. IMPORTANT safety Information... 1 1-1 General Safety Precautions.. 1 1-2 Battery Precautions 1 2. Features. 2 2-1 Electrical

More information

STANDARD COMMENTS 2016 ELECTRICAL PLAN REVIEW CHECK LIST

STANDARD COMMENTS 2016 ELECTRICAL PLAN REVIEW CHECK LIST STANDARD COMMENTS 2016 ELECTRICAL PLAN REVIEW CHECK LIST Item Comments 1. The electrical plan check is approved and ready to have the electrical permit issued, pending the building permit being issued.

More information

Obstruction Lighting Troubleshooting Manual

Obstruction Lighting Troubleshooting Manual Obstruction Lighting Troubleshooting Manual Leaders in LED Lighting & Controls NOTE: USE THIS GUIDE WITH ANY DLS1-008 OR WLS1-008 SYSTEM 3195 Vickery Rd N Syracuse, NY 13212 Ph: (315) 699-4400 or (800)

More information

Single Phase Soft Starters

Single Phase Soft Starters Submittal Data English Language/IP Units 04/14 Contact Information: Hyper Engineering, Pty. Ltd. 4 / 14 Ralph Black Dr Wollongong Nth, NSW 2500 AUSTRALIA www.hypereng.com sales@hypereng.com (877) 304-0724

More information

Enclosed circuit breaker (ECB) with Arcflash Reduction Maintenance System

Enclosed circuit breaker (ECB) with Arcflash Reduction Maintenance System Technical Data TD008010EN Supersedes February 2016 Enclosed circuit breaker (ECB) with Arcflash Reduction Maintenance System The information below is taken directly from the National Electrical CodeT (NEC)

More information

ARC FLASH PPE GUIDELINES FOR INDUSTRIAL POWER SYSTEMS

ARC FLASH PPE GUIDELINES FOR INDUSTRIAL POWER SYSTEMS The Electrical Power Engineers Qual-Tech Engineers, Inc. 201 Johnson Road Building #1 Suite 203 Houston, PA 15342-1300 Phone 724-873-9275 Fax 724-873-8910 www.qualtecheng.com ARC FLASH PPE GUIDELINES FOR

More information

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer 110 Toledo Street Farmingdale, NY 11735 USA http://www.netech.org 510-USER-Manual Rev3 10/29/2007 Dear User, We appreciate your purchase of the LKG

More information

DP&L s Technical Requirements for Interconnection and Parallel Operation of Distributed Generation

DP&L s Technical Requirements for Interconnection and Parallel Operation of Distributed Generation DP&L s Technical Requirements for Interconnection and Parallel Operation of Distributed Generation Technical Requirements for Interconnection and Parallel Operation of Distributed Generation Single Phase

More information

MOTIV SEATING & TABLES

MOTIV SEATING & TABLES MOTIV SEATING & TABLES Designed to support countless configurations. With a wide variety of fabric, leather and power options, MOTIV enables technologies and provides comfort and flexibility for any space.

More information

Trusted Power Distribution Unit MCB 24 Vdc

Trusted Power Distribution Unit MCB 24 Vdc PD-T8292 Trusted Trusted Power Distribution Unit MCB 24 Vdc Product Overview The dual 5-channel Trusted Power Distribution Unit Miniature Circuit Breaker (MCB) 24 V is designed for N+1 or 100 % redundant

More information

Why? Why? "Fatal Four Bureau of Labor Statistics. Monitoring and Metering for Electrical Safety. Shock Fire Explosion Production

Why? Why? Fatal Four Bureau of Labor Statistics. Monitoring and Metering for Electrical Safety. Shock Fire Explosion Production Monitoring and Metering for Electrical Safety Shock Fire Explosion Production Why? Why? "Fatal Four Bureau of Labor Statistics 1. Falls 2. Electrocutions 3. Struck by Object 4. Caught in/between 1 Bureau

More information

Steel Raceways BASE SECTIONS. SnapMark SMS3000 Series FITTINGS, CONNECTORS & BOXES RIGID COUPLING COUPLING BLANK END FITTING ENTRANCE END

Steel Raceways BASE SECTIONS. SnapMark SMS3000 Series FITTINGS, CONNECTORS & BOXES RIGID COUPLING COUPLING BLANK END FITTING ENTRANCE END 22 BASE SECTIONS SMS3000 GRAY BASE - 10FT. (3m).050 galvanized steel. Knockout pattern (.5 [12mm] &.75 [19mm]) in back of raceway, 11 (275 mm) on center. Internal area: 4.90 2 (124mm 2 ) (Order SMS3003

More information

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You Circuit Breakers Excerpt from Master Catalogue Circuit Breakers Specifically For You Hydraulic-magnetic technology ensures reduced nuisance tripping with temperature variance Always holds 00% rated current

More information

4. Classification E: High capacity. 3. Terminal Form Blank: Tab terminals (#250 terminals) Tab terminals #250 SPST-NO

4. Classification E: High capacity. 3. Terminal Form Blank: Tab terminals (#250 terminals) Tab terminals #250 SPST-NO New Product News G9EJ--E Compact Capable of Switching 4 V A DC loads Actualize a high capacity interruption through the function of extinction of magnetic arc by adopting high-efficiency magnetic circuit.

More information

The power to work. Power conditioning products. Harmonic correction unit Sag ride-through power conditioner

The power to work. Power conditioning products. Harmonic correction unit Sag ride-through power conditioner conditioning products Electronic voltage regulator -Sure 700 & 800 -Suppress T7 & 100 Harmonic correction unit Sag ride-through power conditioner The power to work Basics of power quality The partner you

More information

CX-Series. Circuit Breaker

CX-Series. Circuit Breaker CX-Series Circuit Breaker Carling Technologies is proud to introduce the CX-Series circuit breaker, which features a unique and innovative patent pending arc quenching configuration that allows the breaker

More information

Remote Control Outlets Operating Instructions

Remote Control Outlets Operating Instructions Remote Control Outlets Operating Instructions - FOR INDOOR OR OUTDOOR USE - IMPORTANT SAFEGUARDS Signal Word Definitions NOTE: These are general definitions only; all may not pertain to the actual product

More information

Phase-sequence Phase-loss Relay

Phase-sequence Phase-loss Relay Phase-sequence Phase-loss Relay K8AB-PH Three-phase Phase-sequence Phase-loss Relay Using Voltage Detection Method Prevents reverse motor rotation due to incorrect wiring. Distinguishes between positive

More information

Fluke 1660 Series Multifunction Installation Testers

Fluke 1660 Series Multifunction Installation Testers TECHNICAL DATA Fluke 1660 Series Multifunction Installation Testers Reduce test time up to 40 % with Auto Test Auto Test does 5 required installation tests in one sequence, including selectable Type A,

More information

Regal Series Recessed Flatwalls

Regal Series Recessed Flatwalls Regal Series Recessed Flatwalls General Specifications The Amico Regal Series Recessed Flatwall shall be manufactured by Amico Corporation, in accordance with job specific shop drawings and documents.

More information

PORTABLE HALOGEN WORK LIGHT OWNER S MANUAL

PORTABLE HALOGEN WORK LIGHT OWNER S MANUAL PORTABLE HALOGEN WORK LIGHT OWNER S MANUAL L-9001 (29278) L-9002 (29276) WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules

More information

SPECIFICATION, CONTROLS AND ACCESSORIES

SPECIFICATION, CONTROLS AND ACCESSORIES AS440 Automatic Voltage Regulator (AVR) SPECIFICATION, CONTROLS AND ACCESSORIES English Original Instructions A043Y697 (Issue 2) Table of Contents 1. DESCRIPTION... 1 2. SPECIFICATION... 3 3. CONTROLS...

More information

ECE 528 Understanding Power Quality

ECE 528 Understanding Power Quality ECE 528 Understanding Power Quality http://www.ece.uidaho.edu/ee/power/ece528/ Paul Ortmann portmann@uidaho.edu 208-316-1520 (voice) 1 Today Wiring and grounding Why it s important References Terms and

More information

Gross Automation (877)

Gross Automation (877) Carlon Floor Boxes and Covers Round 1-, 2-, and 3-Gang Rectangular Residential Fully Adjustable Drop-In Brass Covers Nonmetallic Covers Carlon Floor Boxes and Covers Contents Adjust-A-Box Residential

More information

Circuit Breakers FAZ / FAZ6. Installation Products for Industrial Applications

Circuit Breakers FAZ / FAZ6. Installation Products for Industrial Applications Circuit Breakers FAZ / FAZ6 Installation Products for Industrial Applications Optimum and powerful protection for every application FAZ up to 15 ka IEC/EN 60947-2 up to 10 ka IEC/EN 60898 up to 10 ka UL

More information

PR-D9CL. GB Version 1

PR-D9CL. GB Version 1 PR-D9CL GB Version 1 Table of contents Important safety instructions... 2-3 Controls... 4-6 Operating your radio Search tuning AM / FM... 8 Manual tuning AM / FM / Setting up the tuning step increment...

More information

ADJUSTABLE SPEED DRIVES. W7 Series. 18 Pulse

ADJUSTABLE SPEED DRIVES. W7 Series. 18 Pulse ADJUSTABLE SPEED DRIVES W7 Series 18 Pulse Meets or Exceeds Your Specifications Standard Specifications Item Voltage Class 460V Maximum HP 60 75 100 125 150 200 250 300 400 500 600 700 800 Drive Rating

More information