variable area flowmeters

Size: px
Start display at page:

Download "variable area flowmeters"

Transcription

1 The ASV Stubbe variable area flowmeter uses a precision moulded transparent tube with a tapered bore, into which is fitted a conical weighted float. The media (water, air, liquid or gaseous chemicals) flows vertically from the bottom to the top. As it passes through the tube, it displaces the float and raises it to a point where equilibrium is established between the lifting force of the media and the weight of the float. The top edge of the float directly indicates the flow volume on the graduated tube scale. Materials for most media: PVC-U, Polyamide (PA), and PVDF Float manufactured from PVDF or Stainless Steel Optional magnetic float for use with limit switches Piping connections to PVC-U, Polypropylene and PVDF (ABS available on request) Two visible scales on each meter: flow rate and percentage (DFM 335 and DFM 350 only) Standard scales in L/hr, optional m 3 /hr or GPM ASV Stubbe meter Prograe Overview Measuring DN Series DFM 1) r MM Inch / 2" / 2" / 2" / 2" / 4" / 4" / 4" / 4" " " " " " " " /4" /4" /2" /2" " " " /2" /2" /2" 1) With water at 20 C 464 IPS Systems l Seaham Grange Industrial Estate l Seham l Co Durham l SR7 0PT l Tel: l

2 VAFM Limit Switch Functions Monostable ZE 950 (48448) Monostable Limit Switch closed Closed when Float is level with switch. Any movement up or down s switch again. Bi-Stable closed ZE 951 (48119) Bi-Stable Limit Switch Normally Open closed ZE 951 (113131) Bi-Stable Limit Switch Normally Closed closed Switch closes as float moves up from below or is level with switch. As float moves up, switch stays closed. Only when moving down below the switch will it again. Switch s as float moves up from below or is level with switch. As float moves up, switch stays. Only when moving down below the switch will it close again. IPS Systems l Seaham Grange Industrial Estate l Seham l Co Durham l SR7 0PT l Tel: l 465

3 ASV Stubbe DFM 165 meter Length: Data Sensor: * meter size and flow rate to be 466 IPS Systems l Seaham Grange Industrial Estate l Seham l Co Durham l SR7 0PT l Tel: l

4 ASV Stubbe DFM 170 meter Length: 170 PVC-U Inch Solvent Socket Connections inch / / / / Data Sensor: * meter size and flow rate to be IPS Systems l Seaham Grange Industrial Estate l Seham l Co Durham l SR7 0PT l Tel: l 467

5 ASV Stubbe DFM 185 meter Length: 185 PVC-U Inch Solvent Socket Connections inch / / / / Data Sensor: * meter size and flow rate to be 468 IPS Systems l Seaham Grange Industrial Estate l Seham l Co Durham l SR7 0PT l Tel: l

6 ASV Stubbe DFM 200 meter Length: 200 PVC-U Inch Solvent Socket Connections inch Data Sensor: * meter size and flow rate to be IPS Systems l Seaham Grange Industrial Estate l Seham l Co Durham l SR7 0PT l Tel: l 469

7 ASV Stubbe DFM 350 meter Length: 350 PVC-U Inch Solvent Socket Connections inch * * * * / / / / / / / * * * * * Residual stocks only - Please check availability Will it be in stock? Last year we shipped more than 27,500 consignments, and more than 95% were complete, first time! 470 IPS Systems l Seaham Grange Industrial Estate l Seham l Co Durham l SR7 0PT l Tel: l

8 Data Sensor: * meter size and flow rate to be IPS Systems l Seaham Grange Industrial Estate l Seham l Co Durham l SR7 0PT l Tel: l 471

flowmeters variable area flowmeters variable area flowmeters ASV Stubbe Flowmeter Programme Overview

flowmeters variable area flowmeters variable area flowmeters ASV Stubbe Flowmeter Programme Overview flowmeters The ASV Stubbe variable area flowmeter uses a precision moulded transparent tube with a tapered bore, into which is fitted a conical weighted float. The media (water, air, liquid or gaseous

More information

tubing & fittings section guide

tubing & fittings section guide tubing & fittings Increasing demands for purity and reliability make the correct selection of materials essential. Used in a wide range of applications and industries such as electronics, chemical processing

More information

SM-15. Features. Plastic Flowmeters as per the Variable Area Principle. Description: Application:

SM-15. Features. Plastic Flowmeters as per the Variable Area Principle. Description: Application: / Flow / Variable Area SM-5 Plastic Flowmeters as per the Variable Area Principle Description: Features / For every industrial application / For fluid and gaseous media / Simple and robust design with

More information

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Float Switches with Permanent Magnet For Vertical Installation Model RSM Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring

More information

FLOAT LEVEL SENSOR TFC. Applications. Reference. Features

FLOAT LEVEL SENSOR TFC. Applications. Reference. Features FLOAT LEVEL SENSOR The label Trafag Industrial Components extends the Trafag brand name to instruments manufactured by qualified partner companies. Trafag Industrial Components complement the genuine Trafag

More information

Ambient Conditions. Operating Conditions. Pressure

Ambient Conditions. Operating Conditions. Pressure Temperature Relative Humidity -20 C +75 C 0% 100 RH to 65 C non condensing 86 106 bar 4.0MPa (DN10 DN80) 1.6MPa (DN100 DN150) 1.0MPa (DN200 DN1000) Remote version < 80 C (rubber coating) Compact version

More information

MIK COMPACT MAGNETO-INDUCTIVE FLOWMETER

MIK COMPACT MAGNETO-INDUCTIVE FLOWMETER MIK COMPACT MAGNETO-INDUCTIVE FLOWMETER Flow Pressure Level Temperature Measurement Monitoring Control Flow Ranges from 0.18-7.8 GPH through 9-180 GPM For Use with a Wide Variety of Conductive Liquids,

More information

Princo MagneLevel Model LML

Princo MagneLevel Model LML Instrumentation designed with the user in mind Instruction Manual Princo MagneLevel Model LML Two-Wire Magnetic Coupled Level Transmitter 11 Nov 05 PRINCO INSTRUMENTS INC., 1020 INDUSTRIAL BLVD., SOUTHAMPTON,

More information

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module / - ; 0 PSI Advantages / Benefits Wireless easy mounting and dismounting of sensor head by a Turn & Lock technique 3-wire Hall version to interface directly with PLC's (both NPN and PNP) Easy to connect:

More information

Electro-Magnetic Flowmeters COPA-XE

Electro-Magnetic Flowmeters COPA-XE Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates

More information

Float switch For industrial applications, plastic version Model RLS-2000

Float switch For industrial applications, plastic version Model RLS-2000 Level measurement Float switch For industrial applications, plastic version Model RLS-2000 WIKA data sheet LM 50.04 Applications Level measurement of liquids in machine building Control and monitoring

More information

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15...

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15... Full Metal Variable Area Flow Meter and Counter for Liquids and Gases monitoring analysing BGN Special versions up to 600 bar O Nominal diameter up to DN 150 S2 Measuring range: 0.5-5.0... 13000-130000

More information

Metal tube variable area flowmeters for gases, liquids and steam

Metal tube variable area flowmeters for gases, liquids and steam Metal tube variable area flowmeters for gases, liquids and steam Metallic with a robust construction, optional in plastic Indication by means of magnetic coupling Linear scales, calibrated in l/h, m3/h,

More information

BGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases

BGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases All Metal Variable Area Flowmeter and Counter for liquids and gases monitoring analysing BGN Measuring range: 0.5-5.0... 13000-130000 l/h water 0.015-0.15... 240-2400 m³/h air (20 C, 1.013 bar) Accuracy

More information

MIM. Electromagnetic Flowmeter. Compact, All-metal Design

MIM. Electromagnetic Flowmeter. Compact, All-metal Design Electromagnetic Flowmeter Compact, All-metal Design measuring monitoring analyzing MIM For Measurement and Monitoring of Conductive iquids Flow and Temperature Measurement Switching, Transmitting, and

More information

Digital conductivity transmitter

Digital conductivity transmitter Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due

More information

INSERTION paddle wheel flowmeter for continuous flow measurement

INSERTION paddle wheel flowmeter for continuous flow measurement INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both

More information

Level Sensors Reed Contact Chain

Level Sensors Reed Contact Chain Level Sensors Reed Contact Chain measuring monitoring analysing Measuring length: Measuring accuracy: 0.5% for L = 2000 mm Pressure: max. 20 bar Temperature: max. 130 C Connection: G 3 8 to G 2 flange:

More information

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual SWITCH 600 Series Velocity Flow Sensor Instruction Manual Ultrasonic Velocity Sensor using Doppler Technology Model: FS-600 Manual Release Date: November, 2009 ECHO Process Instrumentation, Inc. CONTENTS

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Flow Measurement SITRANS F VA. SITRANS FVA250 variable area meter. 4/382 Siemens FI Overview

Flow Measurement SITRANS F VA. SITRANS FVA250 variable area meter. 4/382 Siemens FI Overview Overview Design and mode of operation Like the other units in the range, the SITRANS FVA250 operates according to the variablearea flow tube principle: the flowing medium lifts the conical float in the

More information

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview Siemens AG 2009 Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration

More information

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview Siemens AG 2010 Flow Measurement Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical

More information

Page Type Resolution (mm) min. max. Output

Page Type Resolution (mm) min. max. Output Data Sheet Overview -1- Page Type Resolution (mm) min. max. Output Ind. lenght Ind. lenght 2 XM/XT-800E 5 +/- 2 400 mm 3000 mm current/voltage 6 XM/XT-825E 2.5 +/- 1 200 mm 1500 mm current/voltage 10 XM/XT-800E-PVDF

More information

Full Metal Variable Area Flowmeter and Counter Model BGF

Full Metal Variable Area Flowmeter and Counter Model BGF Full Metal Variable Area Flowmeter and Counter for horizontal and vertical mounting measuring monitoring analysing BGF OO Measuring range: 10-100... 6000-60000 l/h water 0.3-3.0... 170-1700 m³/h air (20

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Level sensor Magnetostrictive, high-resolution measuring principle For sanitary applications, model FLM-H

Level sensor Magnetostrictive, high-resolution measuring principle For sanitary applications, model FLM-H Level measurement Level sensor Magnetostrictive, high-resolution measuring principle For sanitary applications, model FLM-H KSR data sheet FLM-H Applications Food and beverage industry Pharmaceutical industry

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications OPTISONIC 3400 Ultrasonic flowmeter for liquids in all industrial applications Measurement of conductive and non-conductive, low and high viscous liquids, from -200 to +250 C / -328 to +482 F medium temperature

More information

Mineral-insulated resistance thermometers to EN

Mineral-insulated resistance thermometers to EN Data Sheet 90.2221 Page 1/6 Mineral-insulated resistance thermometers to EN 60 751 for temperatures from -50 (-200) to +600 C flexible sheath with shock-protected sensor as single or twin resistance thermometer

More information

Standard Bourdon tube pressure gauges EN 837-1

Standard Bourdon tube pressure gauges EN 837-1 Standard Bourdon tube pressure gauges EN 871 Application For gaseous and liquid media which are not highly viscous, do not crystallize and are not aggressive to copper alloys. For measuring gas or vapour,

More information

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display, DN 15 - DN 50; PN Advantages / Benefits Easy System integration by Easy LINK provides low cost of ownership Easy commissioning due to multi-language, menu-guided operation TEACH-IN: automatic calibration

More information

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E

More information

Screw-in resistance thermometers with terminal head Form B

Screw-in resistance thermometers with terminal head Form B Data Sheet 90.2002 Page 1/7 Screw-in resistance thermometers with terminal head Form B for temperatures from -50 to +600 C with replaceable measuring insert as single or twin resistance thermometer terminal

More information

Target disk flowmeter for liquids and gases

Target disk flowmeter for liquids and gases Target disk flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions Low pressure drop Straight

More information

KDS. All Metal Variable Area Flowmeter. for Liquids and Gases

KDS. All Metal Variable Area Flowmeter. for Liquids and Gases All Metal Variable Area Flowmeter for Liquids and Gases measuring monitoring analysing : 0.1-1... 20-200 water 3-30 Nm3/h... 600-6000 Accuracy: ±3 % of full p max : 420 bar; t max : 130 C Connection: ¼"

More information

Electromagnetic Flow Transmitter

Electromagnetic Flow Transmitter Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be

More information

Operation. LEVEL Transmitters

Operation. LEVEL Transmitters Ultrasonic compact level transmitters for liquids echork GNRL DSCRIPION he high performance level transmitters are based on NIVLCO s 30 years of experience with ultrasonic level measurement. Whether for

More information

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9 Overview MAGFLO family MAGFLO electromagnetic are designed for measuring the flow of electrically conductive mediums. The patented MAGFLO Verificator guarantees accurate measurement and simple verification.

More information

The transducer component converts the measured signal and displays the actual value.

The transducer component converts the measured signal and displays the actual value. Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version

More information

Inductive conductivity transmitter JUMO CTI-Junior

Inductive conductivity transmitter JUMO CTI-Junior M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 (0) 661 60 03-7 25 Fax: +49 (0) 661 60 03-6 81 E-Mail: mail@jumo.net

More information

Level gauges Series LT Level indicator, switch and transmitter for liquids

Level gauges Series LT Level indicator, switch and transmitter for liquids Level gauges Series LT Level indicator, switch and transmitter for liquids Simple construction Resistant under extreme temperature and pressure conditions No risk of leakage Excellent chemical resistance

More information

TIDALFLUX 2300 F Technical Datasheet

TIDALFLUX 2300 F Technical Datasheet Technical Datasheet Electromagnetic flow sensor for partially filled pipes Measurement in partially filled pipes up to DN1600 / 64" Patented, non-contact level measurement Measurement possible down to

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0. Technical Information Condumax W CLS9 Conductivity sensors Two-electrode sensors with cell constants k = 0.0 cm or k = 0. cm Application Measurement in pure and ultrapure water: Monitoring ion exchangers

More information

EE-SPX613. Ordering Information. An Ideal Photomicrosensor for Detecting Liquid Levels in Transparent Pipes

EE-SPX613. Ordering Information. An Ideal Photomicrosensor for Detecting Liquid Levels in Transparent Pipes ASH & ALAIN INDIA PVT LTD S-100, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-110020(India) Tel : 011-43797575 Fax : 011-43797574 E-mail : sales@ashalain.com An Ideal Photomicrosensor for Detecting

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor

More information

Content. Flow meter F2-UN. Description Technical Data Dimension drawings Operation... 8 Mounting instructions...

Content. Flow meter F2-UN. Description Technical Data Dimension drawings Operation... 8 Mounting instructions... Flow meter Content F2-UN Description... 3 Technical data... 4 Dimension drawings... Operation... 8 Mounting instructions... 9 Order code... 10 F1-FP Description... 11 Technical Data... 12 Dimension drawings...

More information

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI Overview Integration The flowmeter pulse output is often used as input for heat calculators. The range of meters enables optimum measurement of energy consumption. The analog output is used to inform the

More information

Process Automation. Sensors and Systems: Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors

Process Automation. Sensors and Systems:  Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors Process Automation Accurate Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors Flexible Sensors and Systems: www.fafnir.com Reliable FAFNIR Sensors and Systems Reliable,

More information

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases Target disk flowmeters Series DP Metallic flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions

More information

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single

More information

BGF. Full Metal Variable Area Flow Meter and Counter. for horizontal and vertical mounting. Special versions up to 600 bar

BGF. Full Metal Variable Area Flow Meter and Counter. for horizontal and vertical mounting. Special versions up to 600 bar Full Metal Variable rea Flow Meter and Counter for horizontal and vertical mounting measuring monitoring analysing BGF Special versions up to 600 bar S2 Measuring range: 10-100... 4000-40000 l/h water

More information

EXCEL EXCEL XR DATA SHEET. Metering Pump. Manual & Enhanced Models. Applications. Performance Specifications. Features and Benefits

EXCEL EXCEL XR DATA SHEET. Metering Pump. Manual & Enhanced Models. Applications. Performance Specifications. Features and Benefits EXCEL XR Metering Pump EXCEL XR Manual & Enhanced Models The EXCEL XR metering pump is a mechanically actuated diaphragm pump driven by advanced variable speed technology to provide the most accurate and

More information

EN-2018 MAGNETIC FLOW METERS

EN-2018 MAGNETIC FLOW METERS EN-2018 MAGNETIC FLOW METERS www.meatest.com 1 MEASURING PRINCIPLE Having no moving or mechanical parts in the flow profile electromagnetic flow meters cause no pressure drop, are virtually maintenance

More information

Measuring and Controlling Unit Multronic OC

Measuring and Controlling Unit Multronic OC Measuring and Controlling Unit Multronic OC One channel measuring and controlling unit for ph / conductivity / Chlorine measuring Automatic temperature compensation Measuring and control behaviour simultaneously

More information

Pressure transmitters SPTW

Pressure transmitters SPTW Product range overview Method of measurement Pressure measuring range [bar] Measured variable Pneumatic connection Operating voltage Electrical connection [V DC] Piezoresistive pressure sensor Thin-film

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to

More information

Resistance thermometers for process technology

Resistance thermometers for process technology Data Sheet 90.2820 Page 1/8 Resistance thermometers for process technology for temperatures from -200 to +600 C with protection tubes in stainless steel, titanium, tantalum, Iconel and Hastelloy available

More information

Electromagnetic flowmeters and switches DWM 1000/2000

Electromagnetic flowmeters and switches DWM 1000/2000 KROHNE 10/2000 D 20 DW10 02 E GR Electromagnetic flowmeters and switches DWM 1000/2000 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass

More information

OPTIMASS 1000 Technical Datasheet

OPTIMASS 1000 Technical Datasheet OPTIMASS 1000 Technical Datasheet Sensor for mass flow First choice for universal applications Best price-performance ratio A wide range of options available with no restrictions The documentation is only

More information

FMG90 Series Electromagnetic Flow Meter

FMG90 Series Electromagnetic Flow Meter . FMG90 Series Electromagnetic Flow Meter - 2 - Series FMG90 Series FMG90 Table of contents page 0 About this operating manual... 4 1 Device description... 5 1.1 Delivery, unpacking and accessories...

More information

Liquid density: from 0,6 g/ml on. Plastic Level Switch NKP Download PDF datasheet

Liquid density: from 0,6 g/ml on. Plastic Level Switch NKP Download PDF datasheet Differential Pressure Transmitter PAD Measuring range: 0,75-15 mbar...4,137-413,7 bar Connection: ¼ NPT, ½ NPT Housing Material: st. st., Hastelloy-C, Monel, Tantalum, Max. temperature: 120 C Accuracy:

More information

NUS-4. Ultrasonic Level Transmitter. for Liquids and Solids

NUS-4. Ultrasonic Level Transmitter. for Liquids and Solids Ultrasonic Level Transmitter for Liquids and Solids measuring monitoring analyzing 4 Measuring Ranges: Liquids: Up to 25 meters (80 feet) Solids: Up to 10 meters (32 feet) Accuracy: ± 0.2 % of Reading

More information

BATCHFLUX 5500 C Technical Datasheet

BATCHFLUX 5500 C Technical Datasheet BATCHFLUX 5500 C Technical Datasheet Electromagnetic flowmeter for volumetric filling machines High-stability ceramic measuring tube, therefore extremely long-term stability Optimum hygienic design Only

More information

Integrated calibration system for electronic and pneumatic instrumentation model CBS-SC2000

Integrated calibration system for electronic and pneumatic instrumentation model CBS-SC2000 Calibration technology Integrated calibration system for electronic and pneumatic instrumentation model CBS-SC2000 WIKA data sheet CT 92.32 Applications Calibration and testing of pneumatic and electronic

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

SPECIFICATION SHEET DISSOLVED OXYGEN ANALYZER/TRANSMITTER SYSTEM CONFIGURATION

SPECIFICATION SHEET DISSOLVED OXYGEN ANALYZER/TRANSMITTER SYSTEM CONFIGURATION ISO-400 ISO-900 SPECIFICATION SHEET DISSOLVED OXYGEN ANALYZER/TRANSMITTER Model: ODM-36A FEATURES Microprocessor based 4-wire transmitter suitable for field installation. The unit features isolated inputs

More information

Clamp Pair. Bore Diameter (mm) Clamp Material PP = Polypropylene PA = Polyamide PE = Polyethylene AL = Aluminum

Clamp Pair. Bore Diameter (mm) Clamp Material PP = Polypropylene PA = Polyamide PE = Polyethylene AL = Aluminum DIN 0 CLAMPS Clamp Pairs HRL = Standard Duty (Ribbed Profile) HRGL = Standard Duty (Smooth Profile) HRS = Heavy Duty (Ribbed Profile) HRGS = Heavy Duty (Smooth Profile) Clamp Pair ore Diameter (mm) Clamp

More information

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0. Technical Information Condumax W CLS9 Conductivity sensors Two-electrode sensors with cell constants k = 0.0 cm or k = 0. cm Application Measurement in pure and ultrapure water: Monitoring ion exchangers

More information

confocaldt 2451/2471 Controller

confocaldt 2451/2471 Controller confocaldt 2451/2471 Controller 70kHz INTER FACE The fastest confocal controller worldwide: up to 70 khz Interfaces: Ethernet / EtherCAT / RS422 / Analog Fast surface compensation Configuration via web

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

OPTITEMP TT 20 Technical Datasheet

OPTITEMP TT 20 Technical Datasheet OPTITEMP TT 20 Technical Datasheet Analog PC-programmable two-wire transmitters for Pt100 Efficient PC-configuration without recalibration Very stable output Very fast response time The documentation is

More information

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI Function All are based on Faraday s law of induction: U M = B v d k U M = Measured voltage induced in the medium perpendicular to the magnetic field and the flow direction. The voltage is tapped at two

More information

F-SERIES FOR. Indicators Totalizers Transmitters Flow computers Batch controllers Monitors. Flow Level Pressure Temperature

F-SERIES FOR. Indicators Totalizers Transmitters Flow computers Batch controllers Monitors. Flow Level Pressure Temperature F-SERIES Indicators Totalizers Transmitters Flow computers Batch controllers Monitors Flow Level Pressure Temperature FOR F - SERIES F - SERIES F - SERIES F - SERIES F - SERIES F - SERIES F - SERIES F

More information

Flow Technologies Overview. For internal use only / Siemens AG All Rights Reserved.

Flow Technologies Overview. For internal use only / Siemens AG All Rights Reserved. Flow Technologies Overview Mag Flow MAGFLO Program Siemens offers a comprehensive selection of electromagnetic flow meters Water & waste water Chemical Food & beverage Mining Aggregates Cement Pharmaceutical

More information

Magnetic Inductive Flow Sensor induq

Magnetic Inductive Flow Sensor induq Operating manual (Translation) Operating manual... page 1-16 Magnetic Inductive Flow Sensor induq Series VMZ SIKA Ba_VMZ_en 10/2014. Please keep this operating manual for future reference. If the device

More information

ULTRASONlC FlOWMETER SAMPLE BOOK. TYPE:LRF-3300S Concentrating on Flow Measurement

ULTRASONlC FlOWMETER SAMPLE BOOK. TYPE:LRF-3300S Concentrating on Flow Measurement ULTRASONlC FlOWMETER SAMPLE BOOK TYPE:LRF-3300S Concentrating on Flow Measurement Introduction LRF-3300S is a wall-mount, clamp- on type ultrasonic flowmeter which use the transfer time technology. Clamp

More information

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display Electromagnetic Wafer Flowmeters with S300 display for corrosive chemicals/acids & slurries (sizes: 2.5mm to 100mm) 0BFEATURES: For aggressive chemicals, slurries, oxides, grouts & dosing applications

More information

B r e a k t h r o u g h F l o wmeter Technology. Ultrasonic Flowmeter Range

B r e a k t h r o u g h F l o wmeter Technology. Ultrasonic Flowmeter Range TM B r e a k t h r o u g h F l o wmeter Technology Ultrasonic Flowmeter Range IDEAL FOR: Drink dispensing Laboratory tests Cooling equipment Active flow alarms Semiconductor plant OEM applications Pilot

More information

MIM. Electromagnetic Flowmeter. Compact, All-metal Design

MIM. Electromagnetic Flowmeter. Compact, All-metal Design Electromagnetic Flowmeter Compact, All-metal Design measuring monitoring analyzing MIM For Measurement and Monitoring of Conductive Liquids Flow and Temperature Measurement Switching, Transmitting, and

More information

UFM 800 W, C Ultrasonic flowmeter for water and wastewater

UFM 800 W, C Ultrasonic flowmeter for water and wastewater KROHNE 08/2000 7.02343.21.00 GR/PRINTO, C Ultrasonic flowmeter for water and wastewater...with weld-in sensors for metal pipelines...withbuilt-on or built-in sensors for open channels Variable area flowmeters

More information

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes GHM Messtechnik GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49 (0) 9402-9383 - 0 Fax +49 (0) 9402-9383 33 www.ghm-messtechnik.de info@ghm-messtechnik.de Flow - Rotor Characteristics Applications

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:

More information

Resistance thermometer Model TR30, compact design

Resistance thermometer Model TR30, compact design Electrical temperature measurement Resistance thermometer Model TR30, compact design WIKA data sheet TE 60.30 Applications Machine building, plant and vessel construction Propulsion technology, hydraulics

More information

WATERFLUX 3000 Quick Start

WATERFLUX 3000 Quick Start WATERFLUX 3000 Quick Start Electromagnetic flow sensor The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000

More information

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA Mobrey Ultrasonic Product Data Sheet February 215 IP245, Rev EA MSP422, MSP4RH, and MSP9GH Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for

More information

FLOWMETER. Siemens MAG 5000/6000. Overview

FLOWMETER. Siemens MAG 5000/6000. Overview Overview Design The transmitter is designed as either IP67 NEMA 4X enclosure for compact or wall mounting or 19" version as a 19 insert as a base to be used in: 19" rack systems Panel mounting IP65/NEMA

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:

More information

P R o D u c T I n F o R m at I o n. TDR Level Sensor LFP. The clean solution

P R o D u c T I n F o R m at I o n. TDR Level Sensor LFP. The clean solution P R o D u c T I n F o R m at I o n TDR Level Sensor The clean solution Level sensors The clean solution Product description The is a hygienic level sensor for liquids using TDR technology a process for

More information

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector No. SS2-MGN200-0200 MagneW3000 PLUS Smart Electromagnetic Flowmeter Open channel Flowmeter Detector Model NNK150/951 OVERVIEW The MagneW3000 PLUS Electromagnetic Flowmeter is submersible type of flowmeter

More information

Indumax CLS50/CLS50D. Technical Information

Indumax CLS50/CLS50D. Technical Information Technical Information Indumax CLS50/CLS50D Inductive conductivity sensor for standard, hazardous and high-temperature applications, analog or digital with Memosens protocol Application Indumax CLS50/CLS50D

More information

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits RHE11 Hazardous Area Multifunction Coriolis Flow Transmitter Features Wall or Pipe Bracket Mount Built in safety barriers allow operation with RHM sensor in hazardous area Selectable Metric and English

More information

Process Automation. Sensors and Systems: Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors

Process Automation. Sensors and Systems:   Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors Process Automation Accurate Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors Flexible Sensors and Systems: www.fafnir.com Reliable FAFNIR Sensors and Systems Reliable,

More information

ANAMET SPIRAL CONDUIT TYPE MPC GREY

ANAMET SPIRAL CONDUIT TYPE MPC GREY ANAMET SPIRAL CONDUIT TYPE MPC GREY Light to normal mechanical strength, extremely flexible Type MPC is a plastic conduit for light and normal mechanical strength. The MPC is very fl exible and has a low

More information

Digital batch controller

Digital batch controller INSERTION Digital batch controller Type 8025 can be combined with... Compact or remote version for DN06 to DN400, PN10 Dosing On site calibration by Teach-In Check of input/output signals Total and daily

More information