Load Cells Page Option Option

Size: px
Start display at page:

Download "Load Cells Page Option Option"

Transcription

1

2 Content: Load Cells Page Option Option Dynamometer, V-LINK 1 Wireless Remote Display, V-LINK 2 Mechanical Overload Switch 3 Static Line Tensiometer 4 Heavy Duty Tensiometer 5 ATEX Running Line Tensiometer 6 Shackle Pin 7 ATEX Load Pin 8 ATEX Junction Box 9 S Cell 10 ATEX OIML Compression Cell 11 Pressure Transducer 12 ATEX Bellows Bending Beam 13 ATEX ET Stainless Series 14 ATEX Bolt-on 15 ATEX OIML Bin Lift 16 ATEX OIML Silo Mount 17 Shear Beam 18 ATEX OIML Button Cell 19 Annular Load Cell 20 Display and Amplifier Options Page Amplifier 21 Panel Meter Display 22 Large Display 23 Remote Control 24 Nykredit Account

3 V-LINK Dynamometer , , , Highly accurate and reliable, ±0,2% FS accuracy. Very clear red digit LED display. Visible at long distances / in bright daylight. IP Class 67. Ideal for wet/humid environments. Robust high strength steel construction for use in hostile environments. Supplied with full certificate of calibration. Delivered in smart carry case from hard ABS plastic. Designed and manufactured in DK for high quality assurance. Application: Crane and hoist calibration and proof load testing Capacity: 6.5T, 12T, 25T, 55T Accuracy: ±0,2% FS Safe overload: 110% Materials: High strenght steel housing. Fe/Zn12/A surface treatment according to ISO 2081 IP class: IP 67 Display: Bright LED Digit height: 14 mm Digit color: Red Operating time: hours (Operating at low temperatures will decrease the operating time) Operation temp.: -20 C C Batteries: Build-in Li-on Charger: High quality USB charger Item No: Capacity (T) A (mm) B (mm) C (mm) D (mm) E (mm) Ø (mm) Weight (kg.) Increment (kg.) Accessory options: WRDTX01 Wirless remote display Nykredit Account 1

4 Remote Display, Wireless WRDTX01 Handheld display for V-LINK Dynamometer. Enables measurements to be read from long distances and moving objects. Up to 99 Dynamometers with remote display can be used in the same area. Very easy to use. Highly reliable and comfortable. Application areas: For use with V-LINK Dynamometer only Range: 150 meters in free range Number of channels: 99 Standard frequency: Mhz Communication form: Duplex RF output power: 10 mw IP class: IP65 Operating time: hours Operating temp.: From -20 C C Batteries: Build-in LI-ON Charger: Standard USB charger, (also used for V-LINK Dynamometer) Item No: Dimensions Weight (kg.) WRDTX01 H145 x L88 x W23 mm 0.15 Nykredit Account 2

5 Load Limiter / Mechanical Overload Switch SM4067, SM4068 Designed for load limitation of hoisting devices and cranes. The compact size provides a minimal lifting height reduction. L150 mm. Quick and precise installation with simple tools. Can easily be adjusted to fit different wire types and capacities. Linear force development gives a user-friendly reaction pattern. Available with 1 or 2 cut off points. Designed and manufactured in DK for high quality assurance. Application areas: Load limitation of hoisting devices, cranes and overhead cranes. Suitable for a variety of industrial environments, including high-temperature and dusty environments. Can be used for low and high weights limits. Materials: Housing: Nickel plated steel. Hysteresis: Operating temp.: Springs: Heat treated spring steel, according to GB/T Axles: Max 4% FS CK45. 0 to 80 C. Below 0 C a heating device is recommended. Switch: UI: 500V UL Listed. Utilisator: AC-15:230V/4A IEC DC-13: 24V / 1A Item No: Wire Capacity Weight Dimensions SM mm kg. per reeving 2,45 kg. W70 x H145 x L150 SM mm kg. per reeving 2,80 kg. W70 x H145 x L150 SM mm kg. per reeving 3,15 kg. W70 x H145 x L150 SM mm kg. per reeving 2,45 kg. W70 x H145 x L150 SM mm kg. per reeving 2,80 kg. W70 x H145 x L150 SM mm kg. per reeving 3,15 kg. W70 x H145 x L150 Nykredit Account 3

6 Static Line Tensiometer WT1-N, WT2-N Combined load indication and load limitation system for hoisting devices, cranes and overhead cranes. Electronic clamp-on tensiometer, universal fit. Highly accurate and reliable, ±1% FS accuracy. Minimal lifting height reduction. Down to L100 mm. Quick and easy to install on the dead end of the wire rope. Designed and manufactured in DK for high quality assurance. Accuracy: ± 1% FS On unit: 0.1% FS Mounted: 0.1% x wire diameter x2. Output: 2.0 Nom MV/V balanced signal. Material: Alu 7075 Temperature: 0,0011 MV/C Input: EXC VDC Cable: 3 mtrs. (Up to 15 mtrs. as option) Item No: Wire (mm) Capacity (T) Dimensions (mm) Weight (kg.) WT1-N 6-15 mm 5T per reeving L100 x W62 x H kg. WT2-N mm 10T per reeving L138x W80 x H kg. Complete systems: WT1-N + OL3000A WT1-N + P1001, D1002, D1004 Tensiometer + Amplifer (load limitation only) Tensiometer + Display w. Amplifer (load indication and limitation) WT1-N WT2-N Nykredit Account 4

7 Heavy Duty Tensiometer WT3 Combined load indication and load limitation system for hoisting devices and cranes with large wires. Electronic clamp-on tensiometer, universal fit. Highly accurate and reliable, ±1% FS accuracy. Fully welded stainless steel construction. Quick and easy to install on the dead end of the wire rope. Supplied with 10 mtrs. cable. Full Load Output: 1.0 nom mv/v Zero Load Output: <±5.0% Excitation (Max): Accuracy: 10 (15) V ±1% FS Repeatability: <0.25% Input Resistance: Output Resistance: 375 (±20) Ω 350 (±2) Ω Compensated Temp. Range: -10 to 40 C Operating Temp. Range: -20 to 60 C Temp. Coefficient on Zero: Temp. Coefficient on Span: Safe Overload: 150% Insulation: <0.0010%Capacity/ C <0.0010%Capacity/ C 100Vdc MΩ IP Class: IP68 Item No: Wire (mm) Capacity (kg.) Dimensions (mm) WT L230 x H116 WT L230 x H116 WT L230 x H116 WT L230 x H116 Complete systems: WT3 + OL3000A WT3 + P1001, D1002, D1004 Tensiometer + Amplifer (load limitation only) Tensiometer + Display w. Amplifer (load indication and limitation) Nykredit Account 5

8 Running Line Tensiometer RLT Combined load indication and load limitation system for moving wires. Accuracy down to 1%. Heavy duty ball bearing construction. Hardened stainless load pin. 3 standard housing models. Wide assortment of mounting accessories. Available in galvanised steel for corrosive environments. Capacity: Wire size: Output signal: IP Class: T according to customer specifications mm 1mv/v at full load IP67 Relative humidity: >98% Operating Temp.: -20 C to +60 C. Under 0 C a heating device is recommended. Item No: Wire (mm) A (mm) B (mm) C (mm) Weight (kg.) RLT RLT RLT RLT RLT RLT RLT RLT RLT Complete systems: RLT + OL3000A RLT + P1001, D1002, D1004 Tensiometer + Amplifer (load limitation only) Tensiometer + Display w. Amplifer (load indication and limitation) RLT PAYOUTCOUNTER Payout counter. Mounting Arm: Wire (mm) D (mm) E (mm) Weight (kg.) RTL MOUNTINGARM RTL MOUNTINGARM RTL MOUNTINGARM Nykredit Account 6

9 Shackle Pin SHA-PIN Robust stainless steel pin & bobbin for use in hostile environments. Highly accurate and reliable, ±0.5% FS accuracy. Bobbin and anti-rotation bracket for centralized, accurate loading. Green Pin shackles. Crosby shackles as option ma output. Telemetry and cabled version, 10 mtrs cable. To ensure the right fit shackles and load pins are always provided together. Full load output: 2.0 nom. mv/v Accuracy: ±0.5% FS Zero load output: <±2.0 % Repeatability: <0.10% Excitation (Max): 10 (15) V Safe overload: 150% Input resistance: 375 or 745 Ω IP class: IP66 Output resistance: 350 or 750 Ω Compensated temp. Range: -10 to 40 C Operating temp. Range: -20 to 60 C Temp. Coefficient on Zero: Temp. Coefficient on Span: <0.005 %Capacity/ C <0.003 %Capacity/ C Insulation: MΩ Capacity: (T) A (mm) B (mm) C (mm) D (mm) L (mm) T (mm) 3,25 (only cabled) , , , Nykredit Account 7

10 Load Pin LOADPIN Combined load indication and load limitation system for hoisting devices, cranes and overhead cranes. Designed according to customers specifications as direct replacement for load bearing pins in lifting equipment. Provides the highest accuracy within weighing, ±0.1% FS accuracy. Robust stainless steel construction. IP68. Capacity: Proof load: Ultimate breaking load: Bridge resistance: Excitation: Output: Non-linearity: Non-repeatability: IP class: Operating temp.: Temp. Coefficient on Zero: Temp. Coefficient on Span: Signal cable: 0.1 to 1000T 150 % of rated load 500 % of rated load 350/700/1000 ohms 5 to 10 volts (dc) 1.0 to 1.5 mv/v ±1 % typical ±0.04 % optimum IP67-20 to 70 C <0.02 % Capacity/ C <0.02 % Capacity/ C 5 mtrs. Polyurethane 4 core Complete systems: LOADPIN + OL3000A LOADPIN + P1001, D1002 Tensiometer + Amplifer (load limitation only) Tensiometer + Display w. Amplifer (load indication and limitation) Options: Special anti-rotation / locking plates Second redundancy gauge bridge Internal signal amplifier Single shear pins fully welded Submersible Internal greaseways plug / socket breakdown at pi Nykredit Account 8

11 Junction Box JB02C-4-WB Junction Box fitted with electronic board for junction and equalisation of 4 and 6 load cells. Fully encapsulated, water proof and moisture proof. Easy connection of the load cells. Not weight dependant. Material: Cast aluminium housing. Protective coasting. Load cell output resistance range: 340 to 1100 Ω Load cell input resistance range: 340 to 1100 Ω Excitation, recommended voltage: 5 to 20V (AC&DC) Excitation, maximum: 30V (AC&DC) Load cell sensitivity range: mv/v Cable Ø: 5 to 6.2 mm Correction method: Excitation trim Trimming range: 24 Ω Temperature range, operating: -40 to 85 C Housing connected to shield: Yes External grounding: No IP Class: IP65 Item No: Amount of connections Dimensions (mm) JB02C-4-WB x 65 x 38 Nykredit Account 9

12 S Cell S-CELL Suitable for hanging, hopper and other weighing devices. Tension and compression applications. Stainless steel construction. Highly accurate and reliable. IP 68. C3 OIML R60 C3 Output sensitivity (= FS): 2.0 ± mv/v 2.0 ± mv/v Max. Numbr of load cell intervals: 3000 Ratio of min. LC verification interval: Combined Error: ± %FS Min. dead load: 0% Safe overload: 150% Ultimate overload: 300% Zero balance: Excitation, recommended voltage: Excitation maximum: Input resistance: Output resistance: Insulation resistance: ± 1.5% FS 5 to12 V 18 V 350 ± 3 Ω 350 ± 3 Ω 5000 (at 50VDC) MΩ Compensated temperature: -10 to 40 C Operating temperature: -35 to 65 C Storage temperature: -40 to 70 C Item No: Capacity Output W (mm) H (mm) Diameter (mm) M (mm) S-CELL500KG-Z1 0.5T 2mV/V Ø99 M12 x 1.75 S-CELL1000KG-Z1 1T 2mV/V Ø99 M12 x 1.75 S-CELL2000KG-Z1 2T 2mV/V Ø99 M20 x 1.5 S-CELL5000KG-Z1 5T 2mV/V Ø99 M24 x 2 Nykredit Account 10

13 Compression Cell - High Capacity COMP Suitable for high precision applications such as dosing systems, machines and other scale applications. Stainless steel construction. Welded cover. Highly accurate and reliable. ±0.1% accuracy. Integral load button. Provided with 4 mtrs. Cable. Full load output: Zero load output: <±2.0% Excitation (Max): 2.0 (±0.25%) mv/v 10 (15) V Accuracy: <0.1% Repeatability: <0.1% Input resistance: Output resistance: 750 (±20) Ω 700 (±2) Ω Compensated temp.: -10 to 50 C Operating temp. Range: -20 to 60 C Temp. Coefficient on zero: Temp. Coefficient on span: Safe overload: 150% <0.005 % capacity/ C <0.005 % capacity/ C IP class: IP68 Item No: Capacity (T) AØ (mm) B (mm) C (mm) DØ (mm) E (mm) F (mm) G (mm) HØ (mm) COMP100T COMP200T COMP300T COMP500T COMP750T Nykredit Account 11

14 Pressure Transducer PRESSTRANS Economical pressure measurement. Sealed gauge operation. Resistant to transients and spikes. Robust stainless steel construction. IP 67 Capacities: 50, 100, 200, 250, 350, 500, 700, 1000 bar. Full load output: 2.0 nom. mv/v Zero balance: <±5.0% Excitation (max): 10 (12) V Accuracy: <0.2% Repeatability: <0.10% Input resistance: 350Ω Output resistance: 350Ω Compensated temp. Range: -10 to 40 C Operating temp. Rage: -20 to 60 C Temp. Coefficient on zero: <0.040 % Capacity/ C Temp. Coefficient on span: <0.040 % Capacity/ C Safe overload: 150% Insulation: MΩ Cable length: 4 mtrs. Item No: PRESSTRANS100B Options: Other ranges and non-standard sizes available on request Cable or plug and socket Connector Amplified outputs (voltage or current) Nykredit Account 12

15 Bellows Bending Beam BELLOWSBEAM Suitable for belt and tank weighing, bag fillers and platforms. Range kg. Stainless steel construction, 17/4/PH. Hermetically sealed. Fully welded. 4 mtrs. Screened polyurethane cable. Easy installation. Rated output: Accuracy class: 2 ±0.1% mv/v 3000 n.oiml Combined error: <±0.017% Non repeatability: <±0.015% Creep 30 mins: <±0.016% Temp. effect on zero: <±0.001%/ C Temp. effect on span: <±0.001%/ C Compensated temp. Range: -10 to 40 C Operating temp. Range: -20 to 60 C Safe overload: 150% Ultimate overload: 200% Zero balance: <1% Input resistance: Output resistance: Insulation resistance: Supply voltage (nominal): Max voltage: 400±20 Ω 350±3 Ω >5000 MΩ@100VDC 10 V 15V Item No: ØA ØB C D E F ØG BELLOWSBEAM ØH J K L M N P Nykredit Account 13

16 ET Stainless Series TD Highly accurate and reliable, ±0.1% FS accuracy. Robust high strength steel construction for use in hostile environments. For use with standard shackles. Sealed to IP 68. Supplied with 10 mtrs. Cable and full certificate of calibration. Full Load Output: 1 (nominal) mv/v Zero Load Output: <±2.0% Excitation (Max): 10 (15) V Repeatability: <0.05% Input Resistance: 375 (±20) Ω Output Resistance: 350 (±2) Ω Compensated Temp. Range: -10 to 40 C Operation Temp. Range: -20 to 60 C Temp. Coefficient on Zero: < %Capacity/ C Temp. Coefficient on Span: < %Capacity/ C Safe Overload: 300% Insulation: MΩ Item No: Capacity (T) A (mm) B (mm) C (mm) D (mm) Dia. (mm) TD1,5 1, TD2,5 2, TD TD7,5 7, TD TD12,5 12, TD TD TD Nykredit Account 14

17 BOLT-ON BOLT-ON Cost effective solution for high capacity. vessel/silo weighing applications. Robust construction. Simple installation. IP65. Supplied with 4 mtrs. Cable and all mounting accessories. BOSS-F BOSS-F Full Load Output: 1.0 nom nom. Zero Load Output: <±5.0% <±5.0% Excitation (Max): 10 (15)V 10 (15)V Accuracy: <0.25% <0.25% Repeatability: <0.04% <0.04% Terminal resistance: 350 nom.ω 2100 nom.ω Deflection: <0.5 mm <0.5 mm Compensated Temp. Range: -10 to 40 C -10 to 40 C Operation Temp. Range: -20 to 60 C -20 to 60 C Temp. Coefficient on Zero: 0.010% Capacity/ C 0.010% Capacity/ C Temp. Coefficient on Span: 0.005% Capacity/ C 0.010% Capacity/ C Safe Overload: 200% 200% Insulation: >5000@100Vdc MΩ >5000@100Vdc MΩ Item No: BOLT-ON Nykredit Account 15

18 Bin Lift Cell BINLIFT CELL Designed for extremely high fatigue stress and impact loads experienced in onbord vehicle weighing. Approved for commercial weighing to OIML R Stainless steel construction. Fully welded. Ideal for hostile environments. High accuracy and durability. Excellent dynamic. Accuracy class: 0.1% C3 DT4650 Rated output 1.0 mv/v ±0,25% 0.88 mv/v Combined error 0.1 %FRO Non-repeatability: 0.02%FRO In accordance with Creep (30 mins): 0.03%FRO OIML Class C3 Temp. coef. of zero: Temp. coef. of span: %FRO %FRO Safe overload: 150 % 150% Ultimate overload: 300 % 300% Zero balance: <1 <1 Input resistance: 380 (±30) Ω 380 (±30) Ω Output resistance: 350 (±2) Ω 350 (±2) Ω Insulation: <5000 M Ω <5000 M Ω Excitation (max): 10 (15) Volts 10 (15) Volts Env. Protection: IP68 IP68 4-core screened cable: 2 mtrs. 2 mtrs. Item No: Capacity A (mm) B (mm) C (mm) D (mm) E (mm) F (mm) G (mm) BIN LIFT CELL 1T 1T 56 35, BIN LIFT CELL 2T 2T 56 35, BIN LIFT CELL 5T 5T 56 35, Nykredit Account 16

19 Silo Mount SILOCELL Complete silo weighing solution incorporating lift off prevention and silo expansion without compromising accuracy. Fully welded sensor. High tensile stainless steel type 17-4PH. High accuracy, durability and corrosion resistance. High resistance to off axis loads. Capacity: 0,5T, 1T, 2T, 5T, 7,5T, 10T, 15T, 20T, 30T, 50T, 75T, 100T Full Load Output: 2.0 (±0.25%) mv/v Zero Load Output: <±2.0% Excitation (Max): 10 (15) V Accuracy (combined error): <0.05% Repeatability: <0.01% Input resistance: 750 (±20) Ω Output resistance: 700 (±2) Ω Compensated Temp. Range: -10 to 40 C Operating Temp. Range: -20 to 60 C Temp. Coefficient on Zero: <0.005 % Capacity/ C Temp. Coefficient on Span: <0.003 % Capacity/ C Safe overload: 150% Insulation: MΩ IP Class: IP68 Cable Length: 10 mtrs. Capacity (T) A (mm) B (mm) C (mm) D (mm) E (mm) ØF No.F G (mm) Mim. Exsp. 1-5T mm 2-20T mm 10-50T mm 75T mm 100T mm Nykredit Account 17

20 Shear Beam SHEARBEAM Suitable for floor scales, vehicle-test line, hopper scales and other electronic weighing devices. Highly accurate and reliable. Stainless steel construction. Sealed to IP68. OIML R60 C3 OIML R60 C4 OIML R60 C5 OIML R60 C6 Output sensitivity (=FS): 2.0 ± 0.04 mv/v 2.0 ± 0.04 mv/v 3.0 ± 0.08 mv/v 3.0 ± 0.08 mv/v Maximum capacity (Emax): 0.5T, 1T, 1.5T, 2T, 2.5T, 3T, 5T, 7.5T, 10T 0.5, 1, 1.5, 2, 2.5T Max. Number of load cell interval: 3000 nlc 4000 nlc 5000 nlc 6000 nlc Ratio of min. LC verification interval: Combined Error: ± %FS ± %FS ± %FS ± %FS Minimum dead load: Safe overload: Ultimate overload: Zero balance: Excitation, recommended voltage: Excitation maximum: Input resistance: Output resistance: Insulation resistance: 0% of Emax 150% of Emax 300% of Emax <± 1.0% of FS 5 to 12 V 18 V 350 ± 3.5 Ω 350 ± 3.5 Ω Compensated temp.: -10 to 40 C Operating temp.: -35 to 65 C 5000 (at 50VDC) MΩ Storage temp.: -40 to 75 C Item No: Capacity (T) L x B x H (mm) ØD (mm) M SHEARBEAM-xxT-z1 0.5, 1, 1.5, x 31.3 x M12 SHEARBEAM-xxT-z1 2.5, x 36.8 x M20 SHEARBEAM-xxT-z1 7.5, x 49.5 x M24 Nykredit Account 18

21 Button Cell BUTTON Capacities 500kN to 20kN. Robust, durable and very compact construction. Highly accurate and reliable. ±0.25% accuracy. Low height. Integral load button. Compression applications. Easy connection to the customers' applications. Full load output: Zero load output: <±2.0%. Excitation (Max): 10 (15) V. Accuracy: <0.25%. Repeatability: <0.01%. 2.0 (±0.25%) mv/v. Input resistance: 375 (±20) Ω. Output resistance: 350 (±2) Ω. Compensated temp.: Operating temp. Range: Temp. Coefficient on zero: Temp. Coefficient on span: Safe overload: 150%. Insulation: -10 C to 40 C. -20 C to 70 C. < % capacity/ C. <0.002 % capacity/ C. 100Vdc MΩ. IP class: IP65. Item No: Capacity (kn) A (mm) B (mm) C (mm) D (mm) Options: BUTTON0.5kN Non-standard sizes available. BUTTON1kN Other ranges on request. BUTTON2kN Special mounting adaptors. BUTTON5kN Shunt calibration facility. BUTTON10kN Different temperature BUTTON20kN compensation available. Nykredit Account 19

22 Annular Load Cell FORCE-WASHER Range 10kN to 200kN. Highly accurate and reliable. Robust, compact and low profile construction. Suitable for metric or imperial bolts. Compression applications. Easy connection to the customers' applications. Provided with 4 mtrs. cable length. Options: Full load output: 1.0 nom. mv/v. Other ranges available on request. Zero load output: <±1.0%. Full range of mounting options. Excitation (Max): 10 (15) V. Non-standard sizes available. Accuracy: <0.5%. Repeatability: <0.10%. Input resistance: 750 Ω. Output resistance: 700 Ω. Compensated temp.: Operating temp. Range: Temp. Coefficient on zero: Temp. Coefficient on span: Safe overload: 150%. Insulation: -10 C to 40 C. -20 C to 60 C. <0.030 % capacity/ C. < % capacity/ C. 100Vdc MΩ. IP class: IP66. Item No: Capacity (kn) Bolt Size A (mm) B (mm) C (mm) FORCE-WASHER10kN 10 M FORCE-WASHER20kN 20 M FORCE-WASHER40kN 40 M FORCE-WASHER80kN 80 M FORCE-WASHER100kN 100 M FORCE-WASHER120kN 120 M FORCE-WASHER160kN 160 M FORCE-WASHER200kN 200 M Nykredit Account 20

23 Chassis Mount Cell CHASSISMOUNT Low height. Stainless load cell. IP 68. High accuracy. Alternative capacities available on request. Accuracy class: 0.5 C1.5 Type CMC Rated output: 1.2 ± 0.25% 0.72 mv/v Combined error: Non-repeatability: 0.5 %FRO 0.3 %FRO Creep (30 mins): 0.03 %FRO In accordance with OIML Temp. Coefficient on zero: %FRO Class C1.5 Temp. Coefficient on span: Compensated temp.: Operating temp. Range: %FRO -10 C to 40 C. -20 C to 60 C. Safe overload: 150% 200% Ultimate overload: 200% 300% Zero balance: <2% <2% Input resistance: 750 (±30)Ω 750 (±30)Ω Output resistance: 700 (±2)Ω 700 (±2)Ω Insulation: >5000 MΩ. >5000 MΩ. Excitation (max): 10(18) Volts 10(18) Volts 4-core screened cable: 10 mtrs. 10 mtrs. Capacity: A (mm) B (mm) C (mm) D (mm) E (mm) F (mm) G (mm) ØH (mm) 10T M T M24 33 Nykredit Account 21

24 Amplifier OL3000A For overload protection on hoist, winches in lifting or crane applications. The load cell amplifier is used in conjunction with load cells as Static Line Tensiometers and Load Pins. Din rail mounted. Accuracy: <0.1% Output: 4-20 ma Features: Relays (n0) triggers at a user set level. Weight: 0.20 kg. Item No: Output Relay Output Dimensions OL3000A VAC 4-20 ma 2 54 x 90 x 61 mm OL3000A VAC 4-20 ma 2 54 x 90 x 61 mm OL3000A VAC 4-20 ma 2 54 x 90 x 61 mm OL3000A VDC 4-20 ma 2 54 x 90 x 61 mm OL3000A-SUM 230 VAC 2 x 4-20 ma 2 54 x 90 x 61 mm Nykredit Account 22

25 Panel Meter P1001/6 Vetec Panel Meter Display is ideal in combination with load cells. Clear, variable brightness display. Provided with and without Relay output (alarms) and special output options. Very easy to programme and use. No-menu programming. High precision and long term reliability. Digits: Viewing: Input signals: Output options: IP Class: Materials: Case dimensions: 6 digits. 14 mm digit height. Up to 7m away. Load cells 4-20mA, 0-10V, 1-5V etc. Serial Data RS232, RS485 etc. 2 or 4 alarms SPST relays, 2x SPDT. 4-20mA, 0-10V or -10 to +10 analog. RS232, RS485, Modbus, Ethernet. RTU Modbus for Tiger G2. IP65 front. 1/8 DIN format case. Black polycarbonate. W 96 x H 48 x L136 mm, (±1mm) Item No.: Digits Digit height Power Supply Analogue Output Relay Output P1001/6-L-R-AC mm VAC - 0 P1001/6-L-R-DC mm VDC - 0 P1001/6-L-ANI-R-AC 6 14 mm VAC 4-20 ma 0 P1001/6-L-ANI-R-DC 6 14 mm VDC 4-20 ma 0 Item No.: Digits Digit height Power Supply Analogue Output Relay Output P1001/6-L-AL2-R-AC 6 14 mm VAC - 2 P1001/6-L-AL2-R-DC 6 14 mm VDC - 2 P1001/6-L-ANI-AL2-R-AC 6 14 mm VAC 4-20 ma 2 P1001/6-L-ANI-AL2-R-DC 6 14 mm VDC 4-20 ma 2 Item No.: Digits Digit height Power Supply Analogue Output Relay Output P1001/6-L-ANI-R-AC 6 14 mm VAC 4-20 ma 0 P1001/6-L-485-R-AC 6 14 mm VAC RS485 0 P1001/6-L-RTU-R-AC 6 14 mm VAC MODBUS RTU (Tiger) 0 P1001/6-L-A2-RTU-R-AC 6 14 mm VAC MODBUS RTU (Tiger) 2 * The listed examples are all with load cell input. Other displays can be provided to meet specific requirements and applications. Nykredit Account 23

26 Large Display D1002, D1004 Vetec Large Display is ideal in combination with load cells. Provided with and without Relay Output (alarms) and special output options. Remote setting from ground level. Very easy to programme and use. No-menu programming. Digits: Input signals: Output options: IP Class: Materials: Available with 4 and 6 digits. Load cells. 4-20mA, 0-10V, 1-5V etc. Serial Data RS232, RS485, 422 etc. 2 or 4 alarms SPST relays, 2x SPDT. 4-20mA, 0-10V or -10 to +10 analog. RS232, RS485, Ethernet data output. IP65 for bottom glands, IP54 for top. Black polycarbonate. Examples, all with load cell input. Item No.: Digits Digit height Viewing Power Supply Relay Output Analogue Output D1002/4-L-R-AC mm 25 mtrs VAC 0 - D1004/4-L-R-AC mm 50 mtrs VAC 0 - D1004/6-L-R-AC mm 50 mtrs VAC 0 - D1004/6-L-R-48VAC mm 50 mtrs. 48 VAC 0 - Item No.: Digits Digit height Viewing Power Supply Relay Output Analogue Output D1002/4-L-AL2-R-AC mm 25 mtrs VAC 2 - D1004/4-L-AL2-R-AC mm 50 mtrs VAC 2 - D1004/6-L-AL2-R-AC mm 25 mtrs VAC 2 - D1004/6-L-AL2-R mm 50 mtrs. 48 VAC 2 - Item No.: Digits Digit height Viewing Power Supply Relay Output Analogue Output D1004/4-L-ANI-AC mm 50 mtrs VAC Ma D1004/4-L-485-AC mm 50 mtrs VAC 0 RS485 D1004/4-L-A2-RTU-AC mm 50 mtrs VAC 2 MODBUS RTU D1004/6-L-A2-RTU-AC mm 50 mtrs VAC 2 MODBUS RTU * Other displays can be provided to meet specific requirements and other applications. Nykredit Account 24

27 Remote Controls TIGER G2 Tiger G2 has been developed for radio controlled lifting applications, e.g. EOT cranes, container cranes and more. Transmitters with display show load indication when combined with our complete load cell systems. For maximum load control and safety. Channels: 69. Approvals: IP Class: The stop function and two relays in the receivers are approved according to SIL3 IEC standard and PLe. Transmitters and receivers are approved according to IP65. TG-T9 transmitters are approved according to IP66. All receivers IP66. Item No.: Frequency Channels Buttons TG-T MHz, 915 MHz and 2,4 GHZ 69 6 TG-T MHz, 915 MHz and 2,4 GHZ TG-T MHz and 915 MHz 69 Joystick TG-T MHz and 915 MHz 69 Joystick Item No.: Frequency Channels Relays TG-R MHz, 915 MHz and 2,4 GHZ TG-R MHz, 915 MHz and 2,4 GHZ TG-R MHz and 915 MHz Nykredit Account 25

28

Load Cells Page Option Option

Load Cells Page Option Option Content: Load Cells Page Option Option Dynamometer, V-LINK 1 Wireless Remote Display, V-LINK 2 Mechanical Overload Switch 3 Static Line Tensiometer 4 Heavy Duty Tensiometer 5 ATEX Running Line Tensiometer

More information

Force and weight measuring instruments

Force and weight measuring instruments JJ Force sensors and load cells JJ Measurement amplifiers JJ Mechanical and electronic accessories JJ Combination units JJ Force calibration systems Force and weight measuring instruments DS_Force_and_weight_measuring_instruments

More information

Type PB Load Cell. Approvals OIML approval to C3 (Y = 7 500; Y = for 375 kg capacity)

Type PB Load Cell. Approvals OIML approval to C3 (Y = 7 500; Y = for 375 kg capacity) Type PB Load Cell IP65 Product Description The type PB is a very low profile planar beam load cell. Its unique Flintec design allows for an extremely low scale construction. Using 3 or 4 type PB load cells

More information

Bestech Australia U14/44 Garden Blvd, Tel: Dingley VIC 3172 Fax:

Bestech Australia U14/44 Garden Blvd, Tel: Dingley VIC 3172 Fax: Load Cell F60X Bending beam load cell made of stainless steel, hermetically sealed. Approved up to 6000d R60 OIML. Level of protection IP 68. ATEX 94/9/CE version for hazardous area (option). Designed

More information

Force and weight measuring instruments

Force and weight measuring instruments JJ Force sensors and load cells JJ Hanging scales JJ Sensors for proof load testing JJ Water filled bags Force and weight measuring instruments DS_Force_and_weight_measuring_instruments 05/2016 97 Force

More information

Weighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier

Weighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 Weighing System Evaluation Mounting DMS strain gauges (load cells), DMS amplifier

More information

Weighing Instruments

Weighing Instruments GHM Messtechnik GmbH Sales Center International Schloßstraße 6 88453 Erolzheim Germany Fon +49-7354-937233-0 Fax -88 www.ghm-messtechnik.de info@ghm-messtechnik.de Weighing Instruments System Evaluation

More information

Bestech Australia U14/44 Garden Blvd, Tel: Dinely VIC 3172 Fax:

Bestech Australia U14/44 Garden Blvd, Tel: Dinely VIC 3172 Fax: Load cell 50... 500 kg High capacity single point load cell made of aluminum. EEC approvals in 3000 d according to OIML R60 and up to 5000 d NTEP. Designed to fit with single point platforms of maximum

More information

U10M. Force Transducer. Special features. Data sheet. Mounting dimensions of the connection variants in mm [inch]

U10M. Force Transducer. Special features. Data sheet. Mounting dimensions of the connection variants in mm [inch] U10M Force Transducer Special features - Precise and robust tensile/compressive force transducer for static and dynamic measurement tasks - High lateral force and bending moment stability, the effect of

More information

Model LBS Miniature Compression Load Button

Model LBS Miniature Compression Load Button Model LBS Miniature Compression Load Button Why the Interface model LBS Miniature Compression Load Button is the best in class: Temperature compensated Integral load button Small diameter From." height

More information

Sensor Datasheet Collection

Sensor Datasheet Collection ISO 9001 REGISTERED Specials are Our Standard Sensor Datasheet Collection CONTENTS HR-DRO: HIGH RESOLUTION DIGITAL READOUT 3 THE RELS FAMILY: ROD-END LOAD SENSORS 4-15 S-RELS SERIES: STANDARD ROD-END LOAD

More information

Remote Radio Control. WAVE Push button radio control systems

Remote Radio Control. WAVE Push button radio control systems Remote Radio Control WAVE Push button radio control systems Application Radio Remote Controls have become a key element within a wide range of modern working environments where safety, productivity and

More information

Load pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1

Load pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1 Force Load pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1 WIKA data sheet FO 51.18 Applications Crane systems and hoists Industrial weighing technology Machine building and plant

More information

U15. Force transducer. Special features. Data sheet. Installed dimensions of connection variants

U15. Force transducer. Special features. Data sheet. Installed dimensions of connection variants U15 Force transducer Special features - Tensile/compressive force transducer - Nominal (rated) forces 2.5 kn to 2.5 MN - lass 0.5 to ISO 376 in force measurement range between 10% and 100% of the nominal

More information

Load pin Heavy Duty with thin film technology from 10 kn Models F5308, F53C8, F53S1

Load pin Heavy Duty with thin film technology from 10 kn Models F5308, F53C8, F53S1 Force Load pin Heavy Duty with thin film technology from 10 kn Models F5308, F53C8, F53S1 tecsis data sheet FO 51.43 Applications Crane systems, hoists, offshore Industrial weighing technology Machine

More information

Load cell system fault finding guide (Application Note: Number AN1)

Load cell system fault finding guide (Application Note: Number AN1) Load cell system fault finding guide (Application Note: Number AN1) Table of Contents Basic checks 3 Basic load cell system............................ 3 Basic load cell resistance checks......................

More information

Load pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1

Load pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1 Force Load pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1 tecsis data sheet FO 51.18 Applications Crane systems and hoists Industrial weighing technology Machine building and plant

More information

Single point load cell

Single point load cell PW15AH Single point load cell Special features - Nominal load 10 kg... 100 kg - Stainless steel - High ratio of minimum verification interval Y - Industrial Footprint (SP4M) - Degree of Protection IP68;

More information

Load Cells LOAD CELLS

Load Cells LOAD CELLS Load Cells Honeywell manufactures a wide range of tension, compression, and universal measurement load cells. Our load cells are industrially rugged and feature enhanced reliability due to stainless steel

More information

Technical data Model F1301 F13C1 ATEX/IECEX 2) F13C1 (Option) Nominal load F nom 10 / 20 / 30 / 50 / 100 / 200 kn 10 / 20 / 30 / 50 / 100 / 200 kn 10

Technical data Model F1301 F13C1 ATEX/IECEX 2) F13C1 (Option) Nominal load F nom 10 / 20 / 30 / 50 / 100 / 200 kn 10 / 20 / 30 / 50 / 100 / 200 kn 10 Compression force transducer with Thin-film sensor Accuracy: 1 % Output signal: 4...20 ma; 2-wire, 0...10 VDC; 3-wire Optional Optional ATEX/IECEX II 2G Ex ib IIC T4/T3 for SIL3-Applications with 2-channel

More information

Tension/compression force transducer. With thin film technology up to 100 kn. Models F2301, F23C1, F23S1. Force. Applications.

Tension/compression force transducer. With thin film technology up to 100 kn. Models F2301, F23C1, F23S1. Force. Applications. Force Tension/compression force transducer With thin film technology up to 100 kn Models F2301, F23C1, F23S1 tecsis data sheet FO 51.17 Applications Crane systems and hoists Industrial weighing technology

More information

Load Cell Accessories and Services

Load Cell Accessories and Services Load Cell Accessories and Services Highlights Strain gage signal conditioners Cable assemblies Mounting accessories Calibration services PCB Piezotronics, Inc. Toll-Free in USA 888-684-0004 716-684-0001

More information

Tension/compression force transducer. With thin film technology up to 100 kn. Models F2301, F23C1, F23S1. Force. Applications.

Tension/compression force transducer. With thin film technology up to 100 kn. Models F2301, F23C1, F23S1. Force. Applications. Force Tension/compression force transducer With thin film technology up to 100 kn Models F2301, F23C1, F23S1 WIKA data sheet FO 51.17 Applications Crane systems and hoists Industrial weighing technology

More information

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition Converter Connection 1-channel EEx ia IIC for 4-wire and 6-wire bridges Analogue output 0/4 ma... 20 ma or 4mA...-12mA Full bridge load cells and strain gauges circuit for resistance bridges up to 17 Ω

More information

Ron 2000 Shackle Type Dynamometer with Remote Indicator

Ron 2000 Shackle Type Dynamometer with Remote Indicator Ron 00 Shackle Type Dynamometer with Remote Indicator Short delivery time: Usually - 4 business days. High quality Aerospace Steel for increased strength and safety. Exceptionally small dimensions enable

More information

Model 3A Series 3-Axis Load Cell

Model 3A Series 3-Axis Load Cell Model 3A Series 3-Axis Load Cell 3-Axis Fx Fy Fz; Independent Bridges 20N to 500kN Force Range Compact Size Low Crosstalk Temperature Compensated Accessories Model 3A60A BSC4A 4-Channel Analog Amplifier

More information

SolidFlow 2.0. Solid mass flow measurement. Product Information. SWR engineering Messtechnik GmbH enveatm a trademark of Environnement S.

SolidFlow 2.0. Solid mass flow measurement. Product Information. SWR engineering Messtechnik GmbH enveatm a trademark of Environnement S. EN SolidFlow.0 Product Information Solid mass flow measurement SWR engineering Messtechnik GmbH enveatm a trademark of Environnement S.A Group Use SolidFlow.0 has been specially developed for measuring

More information

Model 3A Series 3-Axis Load Cell

Model 3A Series 3-Axis Load Cell Model 3A Series 3-Axis Load Cell 3-Axis Fx Fy Fz; Independent Bridges 20N to 500kN Force Range Compact Size Low Crosstalk Temperature Compensated Accessories BSC4A 4-Channel Analog Amplifier BSC4D 4-Channel

More information

Digital conductivity transmitter

Digital conductivity transmitter Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due

More information

Bestech Australia U14/44 Garden Blvd, Tel: Dingley VIC 3172 Fax:

Bestech Australia U14/44 Garden Blvd, Tel: Dingley VIC 3172 Fax: Load Cell F60X Bending beam load cell made of stainless steel, hermetically sealed. Approved up to 6000d R60 OIML. Level of protection IP 68. ATEX 94/9/CE version for hazardous area (option). Designed

More information

Ron 2150 Shackle Type Dynamometer with 2"/50mm Attachable Display

Ron 2150 Shackle Type Dynamometer with 2/50mm Attachable Display Ron Shackle Type Dynamometer with "/0mm Attachable Display Short delivery time: Usually - 4 business days. High quality Aerospace Steel for increased strength and safety. Exceptionally small dimensions

More information

C10. Data sheet. Force transducer. Special features. B de

C10. Data sheet. Force transducer. Special features. B de C10 Force transducer Data sheet Special features Force transducer for static and dynamic applications Made of non-rusting materials Precise (accuracy class from 0.03) Numerous options (double bridge, TEDS,

More information

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver Page 1/13 JUMO Wtrans E01 Measuring probe for humidity, temperature, and CO 2 with wireless data transmission Humidity from 0 to 100 % RH (incl. -40 to +80 C) or CO 2 from 0 to 2000/5000/10000 ppm or Temperature

More information

Operating Manual Series Load Pins

Operating Manual Series Load Pins Operating Manual 5301 Series Load Pins Safety note Use for intended purpose The force transducers in model series F5301 are intended for the measurement of static and dynamic tensile or compressive force.

More information

Model 41E. Precision Low Profile Load Cell DESCRIPTION FEATURES

Model 41E. Precision Low Profile Load Cell DESCRIPTION FEATURES Precision Low Profile Load Cell DESCRIPTION Model 41E is a low profile pancake type load cells. These bonded foil, strain gage load cells are engineered to measure loads from 20 N to 200 kn. The tension/

More information

Non-Submersible Industrial Pressure Transducer

Non-Submersible Industrial Pressure Transducer Non-Submersible Industrial Pressure Transducer KPSI Transducers Series 27, 28, 30 FEATURES Custom Pressure Ranges up to 2000 (13,790 kpa) Accuracy to ±0.10% FS Analog Outputs of 4-20 ma or VDC Welded 316

More information

Single point load cell

Single point load cell PW15AH Single point load cell Special features - Nominal load 10 kg... 100 kg - Stainless steel - High ratio of minimum verification interval Y - Industrial Footprint (SP4M) - Degree of Protection IP68;

More information

MODEL AT-10 ANALOG TRANSMITTER

MODEL AT-10 ANALOG TRANSMITTER MODEL AT-10 ANALOG TRANSMITTER INSTALLATION & OPERATING MANUAL Industrial Weighing Systems 9 Richmond Street Picton, Ontario K0K 2T0 Phone: 613-921-0397 Fax: 613-476-5293 Web: www.iwsystems.ca info@iwsystems.ca

More information

K3D60a ±100N. Description. The K3D60a three-axis sensor is suitable for measuring force on three mutually perpendicular axes.

K3D60a ±100N. Description. The K3D60a three-axis sensor is suitable for measuring force on three mutually perpendicular axes. K3D60a ±100N Description The K3D60a three-axis sensor is suitable for measuring force on three mutually perpendicular axes. The new 3-axis sensor K3D60a is a further development of the series K3D60 and

More information

Picture. Digital output signal (pressure and temperature) RS-485 Modbus RTU, 9600 bps Protocol details see Data Sheet SW

Picture. Digital output signal (pressure and temperature) RS-485 Modbus RTU, 9600 bps Protocol details see Data Sheet SW Type: for level measurement Order No.: see Table 1 / Page 4 Features Picture Four wire system Piezoresistive measuring element Pressure measurement relative or absolute Output signal 4-20 ma and RS-485

More information

GS Strain gauge reader/ transmitter. GS series of wireless industrial sensors. Features: General Description: Applications:

GS Strain gauge reader/ transmitter. GS series of wireless industrial sensors. Features: General Description: Applications: GS series of wireless industrial sensors Strain gauge reader/ transmitter Features: Input: strain gauge Wheatstone bridge: 300ohms to 10kohms. Typical: 1000 ohms. Standard input range: up to 2mV/V full

More information

LOAD MEASURING PINS LE-LU SERIES FEATURES DESCRIPTION APPLICATIONS

LOAD MEASURING PINS LE-LU SERIES FEATURES DESCRIPTION APPLICATIONS LE-LU SERIES LOAD MEASURING PINS Magtrol offers a wide range of Load-Force-Weight Transducers with optional integrated electronics or Load Monitoring Units (LMU) with B.I.T.E. functions creating an ideal

More information

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS2000S Hermetically sealed bending beam load cell

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS2000S Hermetically sealed bending beam load cell BB ME SURE ME NT & N L YT ICS D T SHE ET 9QGPS2000S Hermetically sealed bending beam load cell 2 Measurement made easy High-end load cell combining high accuracy with high resistance in harsh environment.

More information

Torque Sensor Accessories and Services

Torque Sensor Accessories and Services ------------------- Torque Sensor Accessories and Services Highlights Strain gage signal conditioners Cable assemblies Speed sensors Shunt calibration modules and thermocouples Calibration services PCB

More information

Load Cells Shear beam load cells SIWAREX WL230 SB-S SA

Load Cells Shear beam load cells SIWAREX WL230 SB-S SA oad cell Overview Combined error comb Repeatability v ±0.0% C n ±0.0% C n The shear beam load cell is particularly suitable for implementation in container, overhead rail conveyor and platform scales.

More information

OEM radar transmitter, for aggressive media level measurement

OEM radar transmitter, for aggressive media level measurement OEM radar transmitter, for aggressive media level measurement C ompact for level measurement up to 20 m 4... 20 ma/hart - 2 wires Adjustable with P C ATEX approvals Type 8136 can be combined with... Type

More information

Catalog of CLA force and torque sensors

Catalog of CLA force and torque sensors Catalog of CLA force and torque sensors SC-002 LC-01 LC-10 TSF-000 TSF-05 TSF-1 TSF-100 Micro-force sensor Force sensor Micro-torque sensor Torque sensor Phone +41 32 421 44 90, Fax +41 32 421 44 91, ventes@cla.ch,

More information

Remotus. Robust radio remote control for safety critical industrial applications ROBUST SWEDISH DESIGN SINCE 1918

Remotus. Robust radio remote control for safety critical industrial applications ROBUST SWEDISH DESIGN SINCE 1918 Remotus Robust radio remote control for safety critical industrial applications ROBUST SWEDISH DESIGN SINCE 1918 Content INTRODUCTION... 4 REMOTUS JUPITER... 6 TRANSMITTERS RECEIVERS REMOTUS MERCURY...

More information

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Data Sheet MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Submersible Hydrostatic s Rugged and versatile We reserve the right to continuously improve our products and make any change in

More information

Features. Picture. Specifications. Pressure Transmitter 4-20mA 2-wire MPG Type: MPGxxxxxxxx for level measurement Order No.: see Table 1 / Page 4

Features. Picture. Specifications. Pressure Transmitter 4-20mA 2-wire MPG Type: MPGxxxxxxxx for level measurement Order No.: see Table 1 / Page 4 Type: for level measurement Order No.: see Table 1 / Page 4 Features Picture Two wire system Piezoresistive measuring element Pressure measurement relative or absolute Output signal 4-20 ma, adjustable

More information

The transducer component converts the measured signal and displays the actual value.

The transducer component converts the measured signal and displays the actual value. Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version

More information

Shear beam With thin-film technology from 2 kn Models F3301, F33C1, F33S1

Shear beam With thin-film technology from 2 kn Models F3301, F33C1, F33S1 Force Shear beam With thin-film technology from 2 kn Models F3301, F33C1, F33S1 Rated force From 0...2 kn Applications Industrial weighing technology Machine building and plant construction, manufacturing

More information

LOAD CELLS AND WEIGHING SOLUTIONS

LOAD CELLS AND WEIGHING SOLUTIONS LOAD CELLS AND WEIGHING SOLUTIONS SINGLE POINTS S - BEAMS SINGLE ENDED BEAMS DOUBLE ENDED BEAMS CANISTERS & DISCS PLANAR BEAMS LOAD BUTTONS WEIGH MODULES DIGITAL LOAD CELLS SCALES DIGITAL INDICATORS ELECTRONICS

More information

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data Technical documentation Table of content Page 2: Page 3: Page 4: Page 5: Page 6: Page 7: Page 8: Characteristics - applications - technical data Technical data - input quantity - output quantity Electrical

More information

SENEL TECHNOLOGIES S.A. Load Cells Electronic Indicators

SENEL TECHNOLOGIES S.A. Load Cells Electronic Indicators 2009 Load Cells Electronic Indicators Presentation Technologies S.A., is a company that has been created to provide solutions in the field of load cells and weighing electronics, it offers the best solutions

More information

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters Industrial Loop Isolators and Transmitters DSCL,, SCTP DSCL,, SCTP Industrial Loop Isolators and Transmitters Description Dataforth s DSCL,, and SCTP series of products is a complete family of loop and

More information

Features. Picture. Specifications

Features. Picture. Specifications Type: for level measurement Order No.: see Table 1 / Page 5 Features Picture Two wire system Piezoresistive measuring element Output signal 4-20 ma, adjustable within 1 : 4 of the nominal pressure Conformity

More information

C9C. Force Transducer. Special features. Data sheet

C9C. Force Transducer. Special features. Data sheet C9C Force Transducer Special features - Compact design compressive force transducer - Accuracy class 0.2 - Nominal (rated) forces 50 N to 50 kn - Configurable with different cable lengths, plug assembly

More information

LCT100. Load Cell Tester User s Guide (v1711) Anyload Transducer Co. Ltd Website:

LCT100. Load Cell Tester User s Guide (v1711) Anyload Transducer Co. Ltd Website: LCT100 Load Cell Tester User s Guide (v1711) Anyload Transducer Co. Ltd Website: www.anyload.com Email: info@anyload.com A. Basic Steps in Load Cell Testing using the LCT100: 1. Connect the load cell cable

More information

KFS. Flap-type flow meter. Design and range of application

KFS. Flap-type flow meter. Design and range of application Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is

More information

Condumax CLS21 and CLS21D

Condumax CLS21 and CLS21D Technical Information Condumax CLS21 and CLS21D Conductivity sensors, analog or digital with Memosens technology Cell constant k = 1 cm -1 Application Measurements in media of medium and high conductivities:

More information

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 LIST OF CONTENTS Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 Section 2, Calibration Calculations... 7 Calibration Procedure... 8 Section

More information

U2B. Force Transducer. Special features. Data sheet

U2B. Force Transducer. Special features. Data sheet U2B Force Transducer Special features - Tensile/compressive force transducer - Non rusting, degree of protection IP67 - Can be configured with different cable lengths, plug fitting and TEDS on request

More information

Analogue temperature controllers

Analogue temperature controllers Analogue temperature controllers CT8A Input by J-K thermo-couple or by thermo-resistance Pt 00 (-wire) regulation modes : ON/OFF or proportional derivative selected by wiring Relay output Specifications

More information

LB-LE-LU SERIES USER GUIDE LOAD MEASURING PINS.

LB-LE-LU SERIES USER GUIDE LOAD MEASURING PINS. LB-LE-LU SERIES LOAD MEASURING PINS USER GUIDE 01 LB-LE-LU series While every precaution has been exercised in the compilation of this document to ensure the accuracy of its contents, Magtrol assumes no

More information

SS2 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments

SS2 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments Smart Valve Positioner SS2 Linear / Rotary Smart performance with innovative and ever-strong coil drive even under harsh working environments Easy and quick auto-calibration Detecting RA (reverse acting)

More information

A shear beam load cell, with strain gauges, tested as a part of a weighing instrument. Manufacturer : Precia Molen Type : CSI.

A shear beam load cell, with strain gauges, tested as a part of a weighing instrument. Manufacturer : Precia Molen Type : CSI. Test certificate Page 1 of 4 Issued by Hugo de Grootplein 1 3314 EG Dordrecht The Netherlands Notified Body Number 0122 In accordance with Applicant In respect of Paragraph 8.1 of the European Standard

More information

Dx: Digital Multi-Channel Telemetry System

Dx: Digital Multi-Channel Telemetry System Instrumented shaft with signal conditioning and transmitter unit (SCT) and inductive power supply Receiver, Control and Interface Unit (RCI) For measurements with rotating objects, a telemetry system for

More information

Model UG. Ultra Precision Universal Canister Load Cell DESCRIPTION FEATURES

Model UG. Ultra Precision Universal Canister Load Cell DESCRIPTION FEATURES Ultra Precision Universal Canister Load Cell DESCRIPTION Model UG Ultra Precision Universal load cell achieves scale quality and performance standards.the Model UG achieves ±0.03 % non-linearity with very

More information

U2B. Data sheet. Force Transducer. Special features. B en

U2B. Data sheet. Force Transducer. Special features. B en U2B Force Transducer Special features Data sheet Tensile/compressive force transducer Non-rusting, degree of protection IP67 Can be configured with different cable lengths, plug fitting and TEDS on request

More information

4-20mA, 0-10V and general process measuring bargraph displays

4-20mA, 0-10V and general process measuring bargraph displays Page 1 of 6 Digital panel meters Large displays Bargraphs Transmitters 4-20mA, 0-10V process input bargraph displays Display almost any physical variable... The bargraph displays on this page accept most

More information

SILVER SERIES. Reliable compact industrial infrared thermometers for. Temperatures below 3632 F/2000 C Non-reflective target materials Moving targets

SILVER SERIES. Reliable compact industrial infrared thermometers for. Temperatures below 3632 F/2000 C Non-reflective target materials Moving targets SILVER SERIES Low Cost, Single-Wavelength (1λ) Industrial Infrared Thermometers SSDS2013 Reliable compact industrial infrared thermometers for Temperatures below 3632 F/2000 C Non-reflective target materials

More information

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm Electronic pressure measurement Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm WIKA data sheet PE 86.05 Applications Process technology Machine building and plant

More information

Sherborne Sensors is an ISO9001 and AS9100 certified global leader in the design, development, manufacture and supply of high precision

Sherborne Sensors is an ISO9001 and AS9100 certified global leader in the design, development, manufacture and supply of high precision Sherborne Sensors is an ISO9001 and AS9100 certified global leader in the design, development, manufacture and supply of high precision inclinometers, accelerometers, force transducers, load cells, instrumentation

More information

CONTENTS LOAD CELLS / FORCE TRANSDUCERS TR CM CU AM TC TU TH CC CT SB SH CB OC OD CIR CIR-D

CONTENTS LOAD CELLS / FORCE TRANSDUCERS TR CM CU AM TC TU TH CC CT SB SH CB OC OD CIR CIR-D CONTENTS LOAD CELLS / FORCE TRANSDUCERS TR CM CU AM TC TU TH CC CT SB SH CB OC OD CIR CIR-D 3 TR FORCE TRANSDUCER FOR MEASURING THE TENSION ON FIXED OR ROTATING SPINDLES Main features Range of measurement:

More information

Telemetrie-Messtechnik Schnorrenberg

Telemetrie-Messtechnik Schnorrenberg Telemetrie-Messtechnik Schnorrenberg CT16-Wheel User manual TMS Telemetrie-Messtechnik Schnorrenberg Dipl.-Ing. Werner Schnorrenberg Habichtweg 30, D-51429 Bergisch Gladbach, Tel: 02204-9815-52, Fax: 02204-9815-53,

More information

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM SYSTEM OVERVIEW Pollution monitoring of high voltage insulators in electrical power transmission and distribution systems, switchyards and substations is essential in order to minimise the risk of power

More information

Positive Displacement Flow sensors

Positive Displacement Flow sensors JJ Series VZGG JJ Series VZVA JJ Series VZAL JJ Local displays TD5 Positive Displacement Flow sensors DS_Positive_displacement_flow_sensors / 153 Positive displacement flow sensors Gearwheel type flow

More information

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R O P E R AT I O N M A N U A L Model 4800 L O A D C E L L S U M M I N G T R A N S M I T T E R CALEX Manufacturing Company, Inc. Concord, California 94520 Ph: 925/687-4411 800/542-3355 Fax: 925/687-3333 http://www.calex.com

More information

SonoMeter 31 Energy Meters

SonoMeter 31 Energy Meters SonoMeter 31 Energy Meters Description MID examination certificate no.: LT-1621-MI004-023 The Danfoss SonoMeter 31 is a range of ultrasonic, compact energy meters intended for measuring energy consumption

More information

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement Technical Data Sheet Non-Contact, Multiple-Point Measurement The 3DLevelScanner is a noncontact, dust-penetrating bin measurement device that detects irregular surfaces in powder or solid materials and

More information

Data sheet. P3 Top Class BlueLine. P3MBP BlueLine. Ultra-high pressure transducers to 15,000 bar. Special features

Data sheet. P3 Top Class BlueLine. P3MBP BlueLine. Ultra-high pressure transducers to 15,000 bar. Special features Ultra-high pressure transducers to 1,000 bar Data sheet Special features P Top Class BlueLine PMBP BlueLine - For static and dynamic pressure variance, pressure peaks and pressure fluctuations - Principle

More information

EN-2018 MAGNETIC FLOW METERS

EN-2018 MAGNETIC FLOW METERS EN-2018 MAGNETIC FLOW METERS www.meatest.com 1 MEASURING PRINCIPLE Having no moving or mechanical parts in the flow profile electromagnetic flow meters cause no pressure drop, are virtually maintenance

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate True RMS AC Voltage & Current Meter with 1 Cycle Update at 50/60 Hz Features True AC or AC plus DC RMS measurement with crest factor of 3.0 at FS Fast response: reading

More information

Remote Radio Control. M880 WAVE2 C Transmitter Range. M880 for Low Integrity Stop Circuit Applications

Remote Radio Control. M880 WAVE2 C Transmitter Range. M880 for Low Integrity Stop Circuit Applications Application A competitively priced range of remote radio control systems suitable for a wide variety of applications such as industrial doors, forestry machines, recovery vehicle winches / beds, conveyor

More information

U9C. Data sheet. Force Transducer. Special features. B en

U9C. Data sheet. Force Transducer. Special features. B en U9C Force Transducer Data sheet Special features Tensile/compressive force transducer Accuracy class 0.2 Nominal (rated) forces 50 N 50 KN Non-rusting, protection class IP67 Configurable with different

More information

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751 Data sheet Intrinsically safe pressure transmitter MBS 420, MBS 425, MBS 470 and MBS 475 The intrinsically safe pressure transmitter program is designed for use in hazardous environments and offers a reliable

More information

MC2: Practicality for Calibration

MC2: Practicality for Calibration MC2: Practicality for Calibration There are a few must-have tools for an instrument technician: the MC2 is definitely one of them. The MC2 series includes three different hand-held calibrators for field

More information

Model RGH. Rod End In-line Compression/Tension Load Cell DESCRIPTION FEATURES

Model RGH. Rod End In-line Compression/Tension Load Cell DESCRIPTION FEATURES Rod End In-line Compression/Tension Load Cell DESCRIPTION The Model RGH In-Line load cells are high quality, stainless steel, rugged load cells capable of withstanding significant off-axis loads, making

More information

XPC10 High temperature miniature pressure sensor

XPC10 High temperature miniature pressure sensor Absolute, sealed and gauge ranges 10 to 500 bar [150 to 7 500 psi] High temp. operation from -40 up to 220 ºC [-40 to 428 F] Stainless steel construction Amplified output available For static and dynamic

More information

Introduction DIN rail mounted electricity meters

Introduction DIN rail mounted electricity meters Introduction DIN rail mounted electricity meters Modular DIN Rail Products offer a wide range of functions to be integrated in electrical installations with significant benefits for the user. DIN rail

More information

TURCK Inc Campus Drive Minneapolis, MN Application Support: PROX Fax: (763)

TURCK Inc Campus Drive Minneapolis, MN Application Support: PROX Fax: (763) A Sensor Designed with the Customer Applications in Mind! High Accuracy The PS400 and PS500 provide an accuracy rating of ±0.5 percent of the full scale. Flexible Mounting Options Multiple threaded connections

More information

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING Technical leaflet 2 RD.5G.H4.02 Danfoss A/S (IC-MC/mr), 09-2004 Introduction AKS 32 and AKS 33 are pressure transmitters that

More information

Installation and Operating Manual

Installation and Operating Manual GB Analog Weight Transmitter PS-1000 Installation and Operating Manual LIST OF CONTENTS Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 Section

More information

DTM.OCS.S/N - Modbus Level Transmitter

DTM.OCS.S/N - Modbus Level Transmitter Digital Submersible Level Transmitter with Modbus Interface DTM.OCS.S/N - Modbus Level Transmitter CUSTOMER BENEFITS High precision digital level transmitter with standard Modbus interface Fast customization

More information

PM8005/6 PM8005/6. Panel Meter Panel Meter. AC and DC supply options. 5 digit LED display. Direct access menu

PM8005/6 PM8005/6. Panel Meter Panel Meter. AC and DC supply options. 5 digit LED display. Direct access menu PM8005/6 AC and DC supply options 5 digit LED display Direct access menu Functions for calibration, alarm setting and more Wide range of optional functions Description The PM8000 Series digital panel meters

More information

User s instructions. Page 1 sur 20 AXD-C / AAD-C / DVX-C / DVS-C : User s instructions B

User s instructions. Page 1 sur 20 AXD-C / AAD-C / DVX-C / DVS-C : User s instructions B User s instructions Page 1 sur 20 : User s instructions 195752-B Document revisions version date description A 13/01 - Creation B 04/17 - Add DVX-C and DVS-C Page 2 sur 20 : User s instructions 195752-B

More information

Signet 9950 Dual Channel Transmitter

Signet 9950 Dual Channel Transmitter Signet 9950 Dual Channel Transmitter Member of the SmartPro Family of Instruments Features One instrument for multiple sensor types Multiple language support for (Gen 2a) or later in Simplified Chinese,

More information

Signet 9950 Dual Channel Transmitter

Signet 9950 Dual Channel Transmitter Signet 9950 Dual Channel Transmitter Member of the SmartPro Family of Instruments Features One instrument for multiple sensor types Multiple language support for Simplified Chinese, English, French, German

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor

More information