Load Cells LOAD CELLS

Size: px
Start display at page:

Download "Load Cells LOAD CELLS"

Transcription

1 Load Cells Honeywell manufactures a wide range of tension, compression, and universal measurement load cells. Our load cells are industrially rugged and feature enhanced reliability due to stainless steel constructions. We also offer load cells made of carbon steel, and aluminium for applications where these metals are required. Our load cells use bonded foil and semiconductor designed to measure a wide range of force: 25 g to 3,000,000 lb. Honeywell load cells also offer one of the highest levels of accuracy and commercially available today: 0.05 % to 0.5 % full scale, working within temperature ranges from -51 C to 160 C [-60 F to 320 F]. Our custom transducers are capable of handling temperatures above, as well as below, this temperature range. Honeywell s range of outputs are as varied as any manufacturer in the world and they include 1.5 mv/v, 2 mv/v, 15 mv/v, 20 mv/v, and 1 mv/v/ gm. We can also provide on-board amplification (0 V to 5 V or 4 ma to 20 ma) and digital outputs such as RS-232 and RS-485. Honeywell also offers a wide range of load cell sizes including miniature load cells along with an extensive list of connector types including submersible, underwater cable connections. Miniature load cells. Our family of rugged and enhanced accuracy miniature load cells and subminiature load cells are unmatched in their suitability for most harsh environments with tight clearances or confined spaces. Honeywell s load cells cover miniature and subminiature applications for tension/compression and compression style models. Honeywell s unique expertise is in the packaging of its load sensor technology. With a long history of manufacturing subminiature sensors, we offer one of the most comprehensive product line of strain gauge and silicon-based transducers. Load ranges 50 g to 30,000 lbs and accuracies of 0.15 % with a variety of different form factors are available. Many load cells can ship from our extensive quick-ship program, and others are available with customized options or as fully custom designs. Please see our Web site for updated listings ( honeywell.com/tmsensor-ship). Specifications subject to change. Questions? Contact us at either , 143

2 Quick-ship program - load cells Our quick-ship program for test and measurement products includes thousands of finished transducers, load cells, accelerometers, displacement transducers, instrumentation and amplifiers in a wide variety of models and ranges. This diversity readily accommodates most applications, and provides immediate solutions to your urgent sensor needs. To learn more about Honeywell s quick-ship program, visit our Web site or contact our sales support team at ( ). Many load cells can ship from our extensive quick-ship program, and others are available with customized options or as fully custom designs. Many products are included in our quick-ship program. Please see for updated listings. Capacity (Metric) Capacity (Imperial) MODELS 41 41E 31 31E 13 13E 53 53E g X 10 N X X 1000 g X X 5 lb X 50 N X X 10 lb X X 25 lb X X X 200 N X X 50 lb X X X X 100 lb X X X X 200 lb X X 1000 N X X X 250 lb X X 300 lb X 2000 N X X X 500 lb X X X X X X 1000 lb X X X X X X N 2000 lb X X X X 3000 lb X X N 5000 lb X X X X X X lb X X X X X lb X lb X X X X X lb X lb X lb X N X lb X X N X lb X 144 Questions? Contact us at either , Specifications subject to change.

3 Potential application Model Order codes Accuracy Page Low profile Stainless steel 41 41E AL111, 41E 0.1 % 0.1 % Stainless steel fatigue rated BL114 AL116 AL % 0.05% 0.03% Tension/ compression pancake Low capacity fatigue rated P 3140-CS P P 3143-CS CS 0.05 % 0.05 % 0.05 % 0.05 % 0.1 % 0.05 % 0.05 % 0.1 % 0.02 % 0.02 % FR 3149-FR 0.05 % 168 Miniature AL112 BL113 AL131, 53E AL311, 31E AL % 0.01 % 0.5 % 0.1 % 0.1 % , , 203 Subminiature 11 LFH BL321 BL351 AL322, 13E 0.05 % 0.7 % 0.5 % , 215 Canister style Tension and compression UG BL % 0.2 % 0.2 % 0.2 % 0.2 % Specifications subject to change. Questions? Contact us at either , 145

4 Potential application Model Order codes Accuracy Page Canister style Compression MPB BL % 227 Donut style Compression D TH BL912-BL915 BL911 1 % 0.5 % Tension and compression % 0.15 % 5 % In-line Stainless steel tension only RM RH RF see pages see pages see pages 0.2 % 0.2 % 0.2 % Stainless steel RGM RGH RGF AL426/AL626 AL427/AL627 AL428/AL % 0.25 % 0.25 % Tension/compression % 0.15 % S beam 102 BL % 261 Z beam BL810 BL807 BL811 BL % 0.03 % 0.02 % 0.02 % Questions? Contact us at either , Specifications subject to change.

5 Potential application Model Order codes Accuracy Page Load pins MBL MBH LP BL341 BL342 AL % 0.01 % 0.5 % Digital gauge LK LC See page See page 0.2 % Special applications AL-SC AL-JP TL131 TL121 BL803 BL , % 0.15 % 0.02 % 0.02 % 0.1 % 0.1 % 2 % 0.1 % Specifications subject to change. Questions? Contact us at either , 147

6 Model 41 Precision Low Profile Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: AL111 CV 6h Order codes AL111 Order code code Option codes Model 41 precision low profile load cell 5 lb to lb mv/v output Double diaphragm design Intrinsically safe available (2N option only) 16 CE approved 17 AT AV BL BN BR CN CR CV DL DN DP DR DT 5 lb 10 lb 25 lb 50 lb 100 lb 250 lb 500 lb 1000 lb 2000 lb 3000 lb 4000 lb 5000 lb 7500 lb DV EJ EL EN EP ER ET FJ FL FN FP FR lb lb lb lb lb lb lb lb lb lb lb lb Notes 1. Allowable maximum loads - maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 3. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal provides 50 % (unamplified units), 75 % (4 ma to 20 ma 3-wire units) or 80 % (voltage amplified units) of full scale output for quick calibration. Shunt calibration comes standard with internal amplifier option 2b, 2c, 2t and 2j. 4. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown; W=White; G=Green. Color specifying cable and number or letter specifying connector. 5. No mating connector necessary for cable option. 6. Adding any internal amplifiers on 5 lb to 25 lb ranges will increase delivery time. 7. Option 2n (2N) on 5 to 5000 lb. ranges will typically take 12 weeks for delivery. 8. Option 3d is not available with option 2n (2N) or 2k. 9. Not available with option 1c, 1e, 1f, 1g, 1h or 1i. 10. Consult factory. 11. Availability varies with range, consult factory. 12. Option only pertinent when option 2n (2N) selected. 13. Standard calibration for tension/compression load cells is in tension only. 14. Not available with amplified output. 15. Consult factory for TEDS availability with amplified models. 16. dependent; consult factory. Termination dependent; consult factory. 17. Internal amp and termination dependent; consult factory. 18. This unit calibrated to Imperial (non-metric) units. Approved Approved Approved Intrinsically safe amp Specifications Performance Load ranges 18 5 lb to lb Non-linearity, 5 lb to 25 lb ±0.2 % full scale Non-linearity, 50 lb to lb ±0.1 % full scale Hysteresis, 5 lb to 25 lb ±0.1 % full scale Hysteresis, 50 lb to lb ±0.08 % full scale Non-repeatability, 5 lb to 25 lb ±0.1 % full scale Non-repeatability, 50 lb to lb ±0.03 % full scale Output (tolerance), 5 lb to 25 lb 2 mv/v ±0.5 % full scale Output (tolerance), 50 lb to lb 3 mv/v ±0.5 % full scale Operation Compression/tension 13 Resolution Infinite Standard calibration 5-point calibration: 0 %, 50 % and 100 % of full scale in tension only Environmental Temperature, operating -54 C to 121 C [-65 F to 250 F] Temperature, compensated 15 C to 71 C [60 F to 160 F] Temperature effect, zero % full scale/ F Temperature effect, span % full scale/ F Strain gage type Bonded foil Excitation (calibration) 10 Vdc Insulation resistance Vdc Bridge resistance (tolerance) 350 ohm (nominal) Zero balance (tolerance) ±1 % full scale Shunt calibration data Included termination (std) 5 lb to 5000 lb PTIH-10-6P 7500 lb to lb MS3102E-14S-6P Mating connector (not included) 5 lb to 5000 lb PT06A-10-6S or equiv. (AA111) 7500 to lb MS3106A-14S-6S (AA121) Mechanical Maximum allowable load 150 % FS 1 Weight Material Less than 200,000 lb 17-4PH stainless steel Greater than or equal to lb Carbon steel Deflection Natural frequency 148 Questions? Contact us at either , Specifications subject to change.

7 Wiring codes Internal amplifiers Connector A B C D E Unamplified (Std.) (+) excitation (+) excitation (-) excitation (-) excitation (-) output Amplifier specifications Output signal Voltage output: Option 2b Voltage output: Option 2c ±5 V 0-5 V or ±5 45 ma Voltage output: Option 2t 0-10 V or ±10 45 ma Current threewire: Option 2j Current two-wire: Option 2k Intrinsically safe amp: Option 2n (2N)*** 4 ma to 20 ma 4 ma to 20 ma 4 ma to 20 ma F (+) output Input power (voltage) ±15 Vdc or Vdc 11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 15 Vdc to 40 Vdc 9 Vdc to 28 Vdc Deflections and ringing frequencies Capacity (lb) full scale (in) Natural ringing frequency (Hz) 5 to to to to to to to to Weight (lb) Input power (current) Freq. resp (amp) Power supply rej. Operating temp. Reverse voltage protection Short cir. protection Wiring code: connector (std) 4 45 ma 40 ma 40 ma 65 ma 4 ma to 28 ma 4 ma to 24 ma 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz 60 db 60 db 60 db 60 db 60 db 60 db -20 F to 185 F -20 F to 185 F -20 F to 185 F 0 F to 185 F 0 F to 185 F -20 F to 185 F Yes Yes Yes Yes Yes Yes Momentary Momentary Momentary Yes Yes Yes B Output common C Supply return E Shunt Cal 1 F Shunt Cal 2 B Output common** C Supply return** E Shunt Cal 1 F Shunt Cal 2 B Output common** C Supply return** E Shunt Cal 1 F Shunt Cal 2 B Output common** C Supply return** E Shunt Cal 1 F Shunt Cal 2 B No connection C No connection E Case ground F No connection B No connection C No connection E Case ground F No connection Wiring code: cable 4,5,6 Bl Output common G Supply return W (+) Output B Shunt Cal 1 Bl Output com* G Supply return* W (+) Output B Shunt Cal 1 Bl Output com* G Supply return* W (+) Output B Shunt Cal 1 Bl Output com* G Supply return* W (+) Output B Shunt Cal 1 Bl (+) Output W Case ground Bl (+) Output W Case ground Br Shunt Cal 2 Br Shunt Cal 2 Br Shunt Cal 2 Br Shunt Cal 2 Mounting dimensions and characteristics * Black and green wires are internally connected. ** Pins B and C are internally connected. *** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. # s lb D mm H mm H*** mm F# ØG mm B.C. ØK mm thru T A mm A* mm B mm B* mm C mm 5, 10, 25 63,5 [2.50] 20,32 [0.80] 44,45 [1.75] 6 50,8 [2.000] 4,83 [0.19] 1/4-28 UNF 20,83 [0.82] 63,5 [2.5] 19,05 [0.75] 22,86 [0.9] 31,75 [1.25] 50, 100, 250, 500, , 3000, 4000, , 10000, , 30000, ,2 [3.00] 25,4 [1.00] 44,45 [1.75] 6 57,15 [2.250] 7,11 [0.28] 3/8-24 UNF 20,83 [0.82] 63,5 [2.5] 19,05 [0.75] 22,86 [0.9] 31,75 [1.25] 88,9 [3.50] 25,4 [1.00] 44,45 [1.75] 6 66,68 [2.625] 8,64 [0.34] 1/2-20 UNF 20,83 [0.82] 63,5 [2.5] 19,05 [0.75] 22,86 [0.9] 31,75 [1.25] 139,7 [5.50] 45,7 [1.80] 45,7 [1.80] 8 114,3 [4.500] 10,16 [0.40] 1-14 UNS 31,75 [1.25] 58,42 [2.3] 38,1 [1.50] 38,1 [1.5] 50,8 [2.00} 152,4 [6.00] 45,7 [1.80] 45,7 [1.80] 8 123,83 [4.875] 13,46 [0.53] 1 1/2-12 UNF 31,75 [1.25] 58,42 [2.3] 38,1 [1.50] 38,1 [1.5] 50,8 [2.00} 75000, ,6 [9.00] 63,5 [2.50] 63,5 [2.50] ,85 [7.750] 16,76 [0.66] 2-12 UN 31,75 [1.25] 58,42 [2.3] 38,1 [1.50] 38,1 [1.5] 50,8 [2.00} , ,4 [11.00] 63,5 [2.50] 63,5 [2.50] ,3 [9.500] 19,81 [0.78] 2 1/2-12 UN 31,75 [1.25] 58,42 [2.3] 38,1 [1.50] 38,1 [1.5] 50,8 [2.00} , , ,6 [14.00] 107,95 [4.25] 107,95 [4.25] ,45 [11.750] 26,16 [1.03] 3 1/2-8 UN 31,75 [1.25] 58,42 [2.3] 38,1 [1.50] 38,1 [1.5] ** * Length of load cell with amplified option (see option codes) ** C dimension varies on high ranges. Consult factory *** H dimension with 2n(2N) amplifier Special requirements (consult factory) Have a special requirement? New diameter cable, different cable lengths, radiation proof, psi, output options, temperature settings, TEDS IEEE modules, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. Specifications subject to change. Questions? Contact us at either , 149

8 Option codes Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see for updated listings. Load ranges Temperature compensation Internal amplifiers 10 Internal amplifier enhancements Overload stops termination 5, 10, 25, 50, 100, 250, 500, 1000, 2000, 5000, 3000, 4000, 7500, 10000, 15000, 20000, 30000, 50000, 75000, , , , , , lb 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 2b. 4 wire, ±5 Vdc 2c. 0-5 Vdc output 3a. Input/output isolation 19 3d. Remote buffered shunt calibratrion 8 4a. Overload stops 6a. Bendix PTIH-10-6P 6-pin (ranges to 5000 lb) 6b. MS3102E-14S-6P (ranges 7500 lb and up) 9 6e. Integral cable: Teflon 1d. -20 F to 130 F 1e. -20 F to 200 F 1f. 70 F to 250 F 1g. 70 F to 325 F 14 1h. 70 F to 400 F 14 1i. -65 F to 250 F 14 2j ma (three-wire) output 2n (2N) 4 ma to 20 ma (wire) intrinsically safe 20 2k. 4 ma to 20 ma (two-wire) 20 2t. 0 Vdc to 10 Vdc 6f. Integral cable: PVC 6g. Integral cable: Neoprene 9 6h. Integral cable: Silicone 6i. Integral underwater cable 9 6j. 1/2-14 conduit fitting with 5 ft of 4 conductor PVC cable 1j. 0 C to 50 C 1k. -20 C to 85 C 1m. -25 C to 110 C 2u. Unamplified, mv/v output 6q. Molded integral cable polyurethane 9 6v. Phoenix connector on end of cable Shunt calibration 8a. Precision internal resistor 14 Special calibration 9a. 10 point (5 up/5 down) 20 % 68 F 9b. 20 point (10 up/10 down) 10 % 68 F 9c. ASTM E-74 calibration Bridge resistance Zero and span adjustment connector orientation Special calibration Bridge type Shock and vibration 12b ohm (foil) 14a. No access to pots 14b. Top access to pots 15a. Horizontal electrical exit port orientation 15b. Vertical electrical exit port orientation 30a. Compression only calibration, positive in compression 30b. Tension and compression calibration, positive in tension 30c. Compression only calibration, negative in compression 30d. Tension and compression calibration, positive in compression 31a. Dual bridge 44a. Shock and vibration resistance 15c. Radial electrical exit port orientation 15d. Connector on end of cable Interfaces 53e. Signature calibration 14 53t. TEDS IEEE module 15 Typical system diagram Allowable maximum loads 2 Capacity (lb) Side load (lb) Bending (lb-in) Torque (lb-ft) 5 to % 40 % 25 % 50 to % 35 % 25 % 2000 to % 25 % 25 % 7500 to % 20 % 15 % to % 20 % 15 % to % 20 % 15 % % 20 % 10 % % 20 % 10 % % 20 % 10 % 150 Questions? Contact us at either , Specifications subject to change.

9 Model 41E Precision Low Profile Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: 41E 500N0 6i Order codes 41E Order code code Option code Model 41E precision low profile load cell 020N0 20 N 05KN0 5 kn 20N to 200 kn range mv/v output Enhanced thermal stability Double diaphragm design CE approved 050N0 100N0 200N0 500NO 01KN0 02KN0 50 N 100 N 200 N 500 N 1 kn 2 kn 10KN0 20KN0 50KN0 100KN0 200KN0 10 kn 20 kn 50 kn 100 kn 200 kn Notes 1. Allowable maximum loads - maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 3. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal provides 50 % (unamplified units), 75 % (4 ma to 20 ma threewire units) or 80 % (voltage amplified units) of full scale output for quick calibration. Shunt calibration comes standard with internal amplifier option 2a, 2b, 2c, 2t and 2j. 4. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown; W=White; G=Green. Color specifying cable and number or letter specifying connector. 5. No mating connector necessary for cable option. 6. Adding any internal amplifiers on 20 N to 100 N ranges will take typically six weeks for delivery. 7. Not available with amplified option. 8. Option 3d is not available with option 2k. 9. Availability varies with range, consult factory. 10. Consult factory for TEDS availability with amplified models. 11. This unit is calibrated to Metric (non-imperial) units. 12. Input/output isolation only available with voltage output (2b or 2c) ohm bridge required. Specifications Performance Load ranges N to 200 kn Linearity, 20 N to 200 N ±0.2 % full scale Linearity, 500 N to 200 kn ±0.1 % full scale Hysteresis, 20 N to 200 N ±0.1 % full scale Hysteresis, 500 N to 200 kn ±0.08 % full scale Non-repeatability, 20 N to 200 N ±0.05 % full scale Non-repeatability, 500 N to 200 kn ±0.03 % full scale Output (tolerance), 20 N to 200 N 2 mv/v ±0.5 % full scale Output (tolerance), 200 N to 200 kn 3 mv/v ±0.5 % full scale Operation Compression/tension Resolution Infinite Standard calibration Standard calibration for tension/compression load cells is in tension only Environmental Temperature, operating -55 C to 120 C [-67 F to 248 F] Temperature, compensated 15 C to 70 C [60 F to 158 F] Temperature effect, zero % full scale/ C Temperature effect, span % reading/ C Protection rating IP65 9 Strain gage type Bonded foil Excitation (calibration) 10 Vdc Insulation resistance Vdc Bridge resistance (tolerance) 350 ohm (nominal) Shunt calibration data Included termination (std) 20 N to 200 kn PTIH-10-6P bayonet plug (MIL-C-26482) 50 kn to 200 kn MS3102E-14S-6P Mechanical Maximum allowable load 150 % FS 1 Weight Material 20 N to 1.3 kn 17-4PH stainless steel 1.5 kn to 200 kn 4340 painted Deflection 76 micrometers Natural frequency Approved Approved Approved Intrinsically safe amp Specifications subject to change. Questions? Contact us at either , 151

10 Mounting dimensions and characteristics s D mm H mm F# G mm K mm T A mm A* mm B mm B* mm C mm P mm R mm 20 N 64 [2.51] 20 [0.79] 6 51 [2.00] 5 [0.2] M6 x 1.0-6H 21 [0.83] 64 [2.52] 19 [0.75] 23 [0.91] 32 [1.26] 8 [0.31] 5 [0.20] 50 N 64 [2.51] 20 [0.79] 6 51 [2.00] 5 [0.2] M6 x 1.0-6H 21 [0.83] 64 [2.52] 19 [0.75] 23 [0.91] 32 [1.26] 8 [0.31] 5 [0.20] 100 N 64 [2.51] 20 [0.79] 6 51 [2.00] 5 [0.2] M6 x 1.0-6H 21 [0.83] 64 [2.52] 19 [0.75] 23 [0.91] 32 [1.26] 8 [0.31] 5 [0.20] 200 N 76 [2.99] 25 [0.98] 6 60 [2.36] 7 [0.28] M10 x 1.0-6H 21 [0.83] 64 [2.52] 19 [0.75] 23 [0.91] 32 [1.26] 11 [0.43] 7 [0.28] 500 N 76 [2.99] 25 [0.98] 6 60 [2.36] 7 [0.28] M10 x 1.0-6H 21 [0.83] 64 [2.52] 19 [0.75] 23 [0.91] 32 [1.26] 11 [0.43] 7 [0.28] 1 kn 76 [2.99] 25 [0.98] 6 60 [2.36] 7 [0.28] M10 x 1.0-6H 21 [0.83] 64 [2.52] 19 [0.75] 23 [0.91] 32 [1.26] 11 [0.43] 7 [0.28] 2 kn 76 [2.99] 25 [0.98] 6 60 [2.36] 7 [0.28] M10 x 1.0-6H 21 [0.83] 64 [2.52] 19 [0.75] 23 [0.91] 32 [1.26] 11 [0.43] 7 [0.28] 5 kn 76 [2.99] 25 [0.98] 6 60 [2.36] 7 [0.28] M10 x 1.0-6H 21 [0.83] 64 [2.52] 19 [0.75] 23 [0.91] 32 [1.26] 11 [0.43] 7 [0.28] 10 kn 89 [3.50] 25 [0.98] 6 70 [2.76] 9 [0.35] M12 x 1.5-6H 21 [0.83] 64 [2.52] 19 [0.75] 23 [0.91] 32 [1.26] 14 [0.55] 8 [0.31] 20 kn 89 [3.50] 25 [0.98] 6 70 [2.76] 9 [0.35] M12 x 1.5-6H 21 [0.83] 64 [2.52] 19 [0.75] 23 [0.91] 32 [1.26] 14 [0.55] 8 [0.31] 50 kn 140 [5.51] 46 [1.81] [4.49] 10 [0.39] M24 x 1.5-6H 32 [1.26] 58 [2.28] 38 [1.5] 38 [1.5] 51 [2.08] 17 [0.67] 11 [0.43] 100 kn 152 [5.98] 46 [1.81] [4.88] 14 [0.55] M36 x 3.0-6H 32 [1.26] 58 [2.28] 38 [1.5] 38 [1.5] 51 [2.08] NA NA 200 kn 152 [5.98] 46 [1.81] [4.88] 14 [0.55] M36 x 3.0-6H 32 [1.26] 58 [2.28] 38 [1.5] 38 [1.5] 51 [2.08] NA NA * Length of load cell with amplified option (see option codes) Typical system diagram 152 Questions? Contact us at either , Specifications subject to change.

11 Option codes Internal amplifiers Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see honeywell.com/tmsensor-ship for updated listings. Amplifier specifications Voltage output: Option 2b Voltage output: Option 2c Voltage output: Option 2t Current three-wire: Option 2j Current two-wire: Option 2k Load ranges Temperature compensation 20, 50, 100, 200, 500, 1K, 2K, 5K, 10K, 20K, 50K, 100K, 200K N 15 C to 70 C 1j. -65 C to 50 C 1k. -20 C to 85 C Output signal Input power (voltage) ±5 V 0-5 V or ±5 45 ma ±15 V or 26 Vdc to 32 Vdc 0-10 V or ±10 45 ma 4 ma to 20 ma 4 ma to 20 ma 11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 15 Vdc to 40 Vdc Internal amplifiers 6 Internal amplifier enhancements termination 2b. ±5 Vdc 2c. 0 Vdc to 5 Vdc 2j. 4 ma to 20 ma (three-wire) output 2k. 4 ma to 20 ma (two-wire) 13 2t. 0 Vdc to 10 Vdc output 2u. Unamplified, mv/v output 3a. Input/output isolation 12 3d. Remote buffered shunt calibration 8 6-pin bayonet plug (MIL-C-26482) (20 N to 20 kn) MS3102E-14S-6P or equivalent (50 kn to 200 kn) 6e. Integral cable: Teflon 6f. Integral cable: PVC 6g. Integral cable: Neoprene 9 6h. Integral cable: Silicone 9 6i. Integral underwater cable 9 6j. 1/2-14 conduit fitting with 5 ft of 4 conductor PVC cable 6q. Molded integral cable: Polyurethane 9 Shunt calibration 8a. Precision internal resistor 7 Bridge resistance 9 Bridge type Zero and span adjustment connector orientation Load direction Shock and vibration 12a ohm (foil) (max. 200 C) 12b ohm (foil) (max. 120 C) 31a. Dual bridge 14a. No access to pots 14c. Side access to pots 15b. Vertical electrical exit port orientation 15c. Radial electrical exit port orientation 15d. Connector on end of cable 30a. Compression testing only, positive in compression 30b. Tension and compression testing only, positive in tension 30c. Compression testing only, negative in compression 30d. Tension and compression testing only, positive in compression 44a. Shock and vibration resistance Interfaces 53e. Signature calibration 7 53t. TEDS IEEE module 10 Input power (current) Freq. resp (amp) Power supply rej. Operating temp. Reverse voltage protection Short cir. protection Wiring code: connector (std) 4 Wiring code: cable 3,4,5 45 ma 40 ma 40 ma 65 ma 4 ma to 28 ma 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 60 db 60 db 60 db 60 db 60 db -20 F to 185 F -20 F to 185 F -20 F to 185 F 0 F to 185 F 0 F to 185 F Yes Yes Yes Yes Yes Momentary Momentary Momentary Yes Yes B Output common C Supply return E Shunt Cal 1 F Shunt Cal 2 Bl Output common G Supply return W (+) Output B Shunt Cal 1 Br Shunt Cal 2 * Black and green wires are internally connected. ** Pins B and C are internally connected. B Output common** C Supply return** E Shunt Cal 1 F Shunt Cal 2 Bl Output common* G Supply return* W (+) Output B Shunt Cal 1 Br Shunt Cal 2 B Output common** C Supply return** E Shunt Cal 1 F Shunt Cal 2 Bl Output com* G Supply return* W (+) Output B Shunt Cal 1 Br Shunt Cal 2 Deflections and ringing frequencies Capacity Natural ringing frequency (Hz) Weight kg [lb] Capacity B Output common** C Supply return** E Shunt Cal 1 F Shunt Cal 2 Bl Output com* G Supply return* W (+) Output B Shunt Cal 1 Br Shunt Cal 2 Natural ringing frequency (Hz) B No connection C No connection E Case ground F No connection Bl (+) Output W Case ground Weight kg [lb] 20 N ,36 [0.8] 5 kn ,68 [1.5] 50 N ,36 [0.8] 10 kn ,91 [2.0] 100 N ,36 [0.8] 20 kn ,91 [2.0] 200 N ,68 [1.5] 50 kn ,99 [8.8] Wiring codes Connector A B C D E F Unamplified (Std.) (+) excitation (+) excitation (-) excitation (-) excitation (-) output (+) output 500 N ,68 [1.5] 100 kn ,99 [11.0] 1 kn ,68 [1.5] 200 kn ,99 [11.0] 2 kn ,68 [1.5] Special requirements (consult factory) Have a special requirement? New diameter cable, different cable lengths, radiation proof, psi, output options, temperature settings, TEDS IEEE modules, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. Specifications subject to change. Questions? Contact us at either , 153

12 Model 75 Precision Low Profile Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: BL114 CV 6h Order codes BL114 Order code code Option code Model 75 precision low profile load cell 50 lb to lb mv/v output Stainless steel Double diaphragm design 0.10 % accuracy Enhanced overload capacity Intrinsically safe available (2N option only) 8 CE approved 9 BN BR CN CR CV DL DN DP DR DT 50 lb 100 lb 250 lb 500 lb 1000 lb 2000 lb 3000 lb 4000 lb 5000 lb 7500 lb DV EJ EL EN EP ER ET FJ FL lb lb lb lb lb lb lb lb lb Notes 1. C dimension varies on high ranges. Consult factory. 2. Allowable maximum loads - maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 4. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal provides 50 % (unamplified units), 75 % (4 ma to 20 ma threewire units) or 80 % (voltage amplified units) of full scale output for quick calibration. Shunt calibration comes standard with internal amplifier option 2a, 2b, 2c, 2t and 2j. 5. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown; W=White; G=Green. Color specifying cable and number or letter specifying connector. 6. No mating connector necessary for cable option. 7. Consult factory for TEDS availability with amplified models. 8. dependent; consult factory. Termination dependent; consult factory. 9. Internal amp and termination dependent; consult factory. 10. This unit calibrated to Imperial (non-metric) units. 11. Input/output isolation only available with voltage output (2b or 2c) amplifiers ohm bridge required. 13. Cannot be used with amplified option. 14. Cannot be used with options 1c, 1e, 1f, 1g, 1h, or 1i. Specifications Performance Load ranges lb to lb Non-linearity ±0.1 % full scale Hysteresis ±0.1 % full scale Non-repeatability ±0.03 % full scale Output (tolerance) 2 mv/v ±0.5 % full scale Operation Compression/tension Resolution Infinite Standard calibration 5-point calibration, 0 %, 50 %, and 100 % of full scale in tension only Environmental Temperature, operating -54 C to 121 C [-65 F to 250 F] Temperature, compensated 15 C to 71 C [60 F to 160 F] Temperature effect, zero % full scale/ F Temperature effect, span % full scale/ F Strain gage type Bonded foil Excitation (calibration) 10 Vdc Insulation resistance Vdc Bridge resistance (tolerance) 350 ohm Zero balance (tolerance) ±1 % full scale Shunt calibration data Included termination (std) 50 lb to 2000 lb PTIH-10-6P 3000 lb to lb MS3102E-14S-6P Mating connector (not included) 50 lb to 2000 lb PT06A-10-6S or equiv. (AA111) 3000 to lb MS3106A-14S-6S (AA121) Mechanical Maximum allowable load 200 % FS 2 Weight Material Less than or equal to lb 17-4PH stainless steel Greater than or equal to lb Carbon steel Life cycles (approx.) > 10 8 cycles fully reversed Deflection Natural frequency Approved Approved Approved Intrinsically safe amp 154 Questions? Contact us at either , Specifications subject to change.

13 Wiring codes Internal amplifiers Connector A B C D Unamplified (Std.) (+) excitation (+) excitation (-) excitation (-) excitation Amplifier specifications Voltage output: Option 2b Voltage output: Option 2c Voltage output: Option 2t Current three-wire: Option 2j Current two-wire: Option 2k Intrinsically safe amp: Option 2n (2N)*** E F (-) output (+) output Output signal ±5 V 0 V to 5 V or ±5 45 ma 0 V to 10 V or ±10 45 ma 4 ma to 20 ma 4 ma to 20 ma 4 ma to 20 ma Deflections and ringing frequencies Capacity (lb) full scale (in) Natural ringing frequency (khz) Weight g [lb] 50 to [1.61] 1000 to [1.98] 3000 to [8.82] to [11.02] to [18.96] to [33.07] to [46.3] Input power (voltage) Input power (current) Freq. resp (amp) Power supply rej. Operating temp. Reverse voltage protection Short cir. protection ±15 V or 26 Vdc to 32 Vdc 11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 15 Vdc to 40 Vdc 45 ma 40 ma 40 ma 65 ma 4 ma to 28 ma 9 Vdc to 28 Vdc 4 ma to 24 ma 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz 60 db 60 db 60 db 60 db 60 db 60 db -20 F to 185 F -20 F to 185 F -20 F to 185 F 0 F to 185 F 0 F to 185 F -20 F to 185 F Yes Yes Yes Yes Yes Yes Momentary Momentary Momentary Yes Yes Yes Wiring code: connector (std) 4 B Output common C Supply return E Shunt cal 1 F Shunt cal 2 B Output common** C Supply return ** E Shunt cal 1 F Shunt cal 2 B Output common** C Supply return** E Shunt cal 1 F Shunt cal 2 B Output common** C Supply return** E Shunt cal 1 F Shunt cal 2 B No connection C No connection E Case ground F No connection B No connection C No connection E Case ground F No connection Wiring code: cable 4,5,6 Bl Output common G Supply return W (+) Output B Shunt cal 1 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Bl (+) Output W Case ground Bl (+) Output W Case ground Br Shunt cal 2 Br Shunt cal 2 Br Shunt cal 2 Br Shunt cal 2 Mounting dimensions and characteristics s lb D mm H mm F # ØG mm B.C. ØK mm thru * Black and green wires are internally connected. ** Pins B and C are internally connected. *** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. # T A mm A* mm B mm B* mm C mm 50 to ,2 [3.00] 25,4 [1.00] 6 57,15 [2.250] 7,11 [0.28] 3/8-24 UNF 20,83 [0.82] 63,5 [2.5] 19,05 [0.75] 22,86 [0.9] 31,75 [1.25] 1000 to ,9 [3.50] 25,4 [1.00] 6 66,68 [2.625] 8.64 [0.34] 1/2-20 UNF 20,83 [0.82] 63,5 [2.5] 19,05 [0.75] 22,86 [0.9] 31,75 [1.25] 3000 to ,7 [5.50] 45,72 [1.80] 8 114,3 [4.500] 10,16 [0.40] 1-14 UNS 31,75 [1.25] 58,42 [2.3] 38,1 [1.50] 38,1 [1.5] 50,8 [2.00] to ,4 [6.00] 45,72 [1.80] 8 123,83 [4.875] 13,46 [0.53] 1 1/2-12 UN 31,75 [1.25] 58,42 [2.3] 38,1 [1.50] 38,1 [1.5] 50,8 [2.00] to ,5 [7.50] 50,8 [2.00] 8 152,4 [6.00] 19,81 [0.78] 2-12 UN 31,75 [1.25] 58,42 [2.3] 38,1 [1.50] 38,1 [1.5] 50,8 [2.00] to ,6 [9.0] 63,5 [2.50] ,85 [7.75] 16,76 [0.66] 2 1/2-12 UN 31,75 [1.25] 58,42 [2.3] 38,1 [1.50] 38,1 [1.5] 50,8 [2.00] , ,6 [14.00] 107,95 [4.25] ,45 [11.750] 26,16 [1.03] 3 1/2-8 UN 31,75 [1.25] 58,42 [2.3] 38,1 [1.50] 38,1 [1.50] ** Specifications subject to change. Questions? Contact us at either , 155

14 Option codes Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see honeywell.com/tmsensor-ship for updated listings. Load ranges 50, 100, 250, 500, 1000, 2000, 3000, 4000, 5000, 7500, 10000, 15000, 20000, 30000, 50000, 75000, , lb Temperature compensation Internal amplifiers Internal amplifier enhancements termination 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 1d. -20 F to 130 F 1e. -20 F to 200 F 1f. 70 F to 250 F 2b. Four wire, ±5 Vdc output 2c. 0 Vdc to 5 Vdc 2j. 4 ma to 20 ma (three-wire) output 2k. 4 ma to 20 ma (two-wire) 12 3a. Input/output isolation 11 3d. Remote buffered shunt calibration 8 6a. Bendix PTIH-10-6P (ranges to 2000 lb) 6b. MS connector MS3102E-14S-6P (mates with MS3106E-14S-6S) (max. 160 F) (ranges 2000 lb and above) 14 6e. Integral cable: Teflon 6f. Integral cable: PVC Shunt calibration 8a. Precision internal resistor 13 Bridge resistance Bridge type Zero and span adjustment connector orientation Special calibration Shock and vibration 12b ohm (foil) (max. 250 F) 31a. Dual bridge 14a. No access to pots 14b. Top access to pots 15a. Horizontal electrical exit port orientation 15b. Vertical electrical exit port orientation 15c. Radial electrical exit port orientation 15d. Connector on end of cable 1g. 70 F to 325 F 13 1h. 70 F to 400 F 13 1i. -65 F to 250 F 13 1j. 0 C to 50 C 1k. -20 C to 85 C 1m. -25 C to 110 C 30a. Compression only calibration, positive in compression 30b. Tension and compression calibration, positive in tension 44a. Shock and vibration resistance 2n (2N) 4 ma to 20 ma (two-wire) intrinsically safe 12 2t. 0 Vdc to 10 Vdc output 2u. Unamplified, mv/v output 6g. Integral cable: Neoprene 6h. Integral cable: Silicone 6i. Integral underwater cable 6j. 1/2-14 conduit fitting with 5 ft of 4 conductor PVC cable Allowable maximum loads 2 Capacity (lb) Side load (lb) Bending (lb-in) Torque (lb-ft) 50 to % 60 % 35 % 1000 to % 35 % 35 % 3000 to % 30 % 25 % to % 30 % 25 % to % 30 % 15 % to % 30 % 15 % to % 30 % 15 % Typical system diagram Interfaces 53e. Signature calibration 13 53t. TEDS IEEE module 7 Special requirements (consult factory) Have a special requirement? New diameter cable, different cable lengths, radiation proof, psi, output options, temperature settings, TEDS IEEE modules, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. 156 Questions? Contact us at either , Specifications subject to change.

15 Model 45 Fatigue Rated Universal Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: AL116 CV 6h Order codes AL116 Order code code Option code Model 45 fatigue rated universal load cell Base plate order information s Base plate order code Base plate weight kg [lb] Load button order code 250 lb to 1000 lb AA229 1,59 [3.5] AA lb to lb Long fatigue life Accuracy up to 0.04 % Intrinsically safe available (2N option only) 12 CE approved 13 Notes 1. Static error band is the recommended performance specification. The static error band is calculated as the best fit straight line through zero, including the effects of non-linearity, hysteresis and non-repeatability. 2. Values noted are typical values but fall within the static error. 3. Allowable maximum loads maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 5. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal provides 50 % (unamplified units), 75 % (4 ma to 20 ma threewire units) or 80 % (voltage amplified units) of full scale output for quick calibration. Shunt calibration comes standard with internal amplifier option 2c, 2t and 2j. 6. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown; W=White; G=Green. Color specifying cable and number or letter specifying connector. 7. No mating connector necessary for cable option lb. range has 700 ohm bridge resistance. 9. Off axis loading maximum allowable 50 % full scale. 10. Internal amplifier for ranges less than 12,500 lb may increase in height. 11. Consult factory for TEDS availability with amplified models. 12. dependent; consult factory. Termination dependent; consult factory. 13. Internal amp and termination dependent; consult factory. 14. This unit calibrated to Imperial (non-metric) units ohm bridge required. 16. Cannot be used with amplified option. 17. Cannot be used with options 1c, 1e, 1f, 1g, 1h, or 1i lb to 5000 lb AA229 1,59 [3.5] AA lb to lb AA230 4,99 [11] AA lb AA231 9,07 [20] AA lb AA232 27,67 [61] AA293 CN CR CV DM DR Specifications Performance Load ranges lb 500 lb 1000 lb 2500 lb 5000 lb 250 lb to lb Accuracy (static error band) 1,2 Linearity Hysteresis 250 lb to 1000 lb ±0.04 % full scale ±0.04 % full scale ±0.03 % full scale 2500 lb to lb ±0.05 % full scale ±0.05 % full scale ±0.05 % full scale lb ±0.06 % full scale ±0.05 % full scale ±0.05 % full scale Non-repeatability ±0.02 % full scale Output 2 mv/v Tolerance on output ±1 % full scale Creep in 20 min. (max.) 0.01 % Environmental Temperature, operating -54 C to 93 C [-65 F to 200 F] Temperature, compensated -1 C to 54 C [30 F to 130 F] Temperature effect, zero % full scale/ F Temperature effect, span % reading/ F Strain gage type Foil Excitation (calibration) 10 Vdc Excitation (acceptable) 20 Vdc Insulation resistance V Bridge resistance (tolerance) 350 ohm (nominal) 8 Zero balance (tolerance) ±1 % full scale Shunt calibration data Included termination (std) PC02A-10-6P Mating connector (not included) PC06A-10-6S Mechanical Maximum allowable load 200 % FS 3, 9 Weight Case material Stainless steel Life cycles (approx.) > 10 8 cycles fully reversed Deflection Natural frequency DW EM EP ET lb lb lb lb Specifications subject to change. Questions? Contact us at either , 157

16 Option codes Internal amplifiers Load ranges Temperature compensation Internal amplifiers Many range/option combinations are available in our quickship and fast-track manufacture programs. Please see sensing.honeywell.com/tmsensor-ship for updated listings. 250, 500, 1000, 2500, 5000, 12500, 2500, 50000, lb 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 1d. -20 F to 130 F 1e. -20 F to 200 F 1f. 70 F to 250 F 2b. ±5 Vdc output 2c. 0 Vdc to 5 Vdc 2j. 4 ma to 20 ma (three-wire) output 2k. 4 ma to 20 ma (two-wire) 15 1g. 70 F to 325 F 16 1h. 70 F to 400 F 16 1i. -65 F to 250 F 16 1j. 0 C to 50 C 1k. -20 C to 85 C 1m. -25 C to 110 C 2n (2N) 4 ma to 20 ma (two-wire) intrinsically safe 15 2t. 0 Vdc to 10 Vdc output 2u. Unamplified, mv/v output Amplifier specifications Output signal Input power (voltage) Input power (current) Voltage output: Option 2b Voltage output: Option 2c ±5 V 0 V to 5 V or ±5 45 ma ±15 V or 26 Vdc to 32 Vdc 11 Vdc to 28 Vdc Voltage output: Option 2t 0 V to 10 V or ±10 45 ma 15 Vdc to 28 Vdc Current three-wire: Option 2j Current two-wire: Option 2k Intrinsically safe amp: Option 2n (2N)*** 4 ma to 20 ma 4 ma to 20 ma 4 ma to 20 ma 22 Vdc to 32 Vdc 15 Vdc to 40 Vdc 9 Vdc to 28 Vdc 45 ma 40 ma 40 ma 65 ma 4 ma to 28 ma 4 ma to 24 ma Internal amplifier enhancements termination 3d. Remote buffered shunt calibration Shunt calibration 8a. Precision internal resistor 16 Special calibration Bridge type connector orientation Shock and vibration PC02A-10-6P 6a. Bendix PTIH-10-6P (or equivalent), 6-pin (max. 250 F) 6b. MS connector MS3102E-14S-6P (mates with MS3106E-14S-6S) (max. 160 F) 17 9c. ASTM E-74 calibration 30a. Compression only calibration, positive in compression 30b. Tension and compression calibration, positive in tension 30c. Compression only calibration, negative in compression 30d. Tension and compression calibration, positive in compression 31a. Dual bridge 11c. Square and symmetrical bridge 16 15a. Horizontal electrical exit port orientation 44a. Shock and vibration resistance Interfaces 53e. Signature calibration 16 53t. TEDS IEEE module 11 Mounting dimensions and characteristics Freq. resp (amp) Power supply rej. Operating temp. Reverse voltage protection Short cir. protection Wiring code: connector (std) 5 Wiring code: cable 5,6, Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz 60 db 60 db 60 db 60 db 60 db 60 db -20 F to 185 F -20 F to 185 F -20 F to 185 F 0 F to 185 F 0 F to 185 F -20 F to 185 F Yes Yes Yes Yes Yes Yes Momentary Momentary Momentary Yes Yes Yes B Output common C Supply return E Shunt cal 1 F Shunt cal 2 Bl Output common G Supply return W (+) Output B Shunt cal 1 Br Shunt cal 2 B Output common** C Supply return ** E Shunt cal 1 F Shunt cal 2 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 B Output common** C Supply return** E Shunt cal 1 F Shunt cal 2 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 B Output common** C Supply return** E Shunt cal 1 F Shunt cal 2 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 B No connection C No connection E Case ground F No connection Bl (+) Output W Case ground * Black and green wires are internally connected. ** Pins B and C are internally connected. *** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. # B No connection C No connection E Case ground F No connection Bl (+) Output W Case ground LOAD CELL s lb Ø D1 mm H mm T ØB mm N mm F1 250, 500, 1000, 2500, ,65 [4.12] 34,8 [1.37] 5/8-18 UNF-3B 34,0 [1.34] 3,05 [0.12] 9/32 in dia., 8 holes eq. sp., 3.50 B.C , ,92 [6.06] 44,45 [1.75] 1 1/4-12 UNF-3B 67,31 [2.65] 3,05 [0.12] 13/32 in dia., 12 holes eq. sp., B.C ,2 [8.00] 63,5 [2.50] 1 3/4-12 UNF-3B 95,50 [3.76] 6,35 [0.25] 17/32 in dia., 16 holes eq. sp., 6.50 B.C ,4 [11.00] 88,9 [3.50] 2 3/4-8 UNF-3B 122,17 [4.81] 12,7 [0.50] 11/16 in dia., 16 holes eq. sp., 9.00 B.C. PULL PLATE s lb Order code ØD2 mm L mm T ØG mm F2 250, 500, 1000, 2500, 5000 AA ,65 [4.12] 28,45 [1.12] 5/8-18 UNF-3B 31,75 [1.25] 1/4-28, 8 holes eq. sp., 3.50 B.C , AA ,92 [6.06] 44,45 [1.75] 1 1/4-12 UNF-3B 57,15 [2.25] 3/8-24, 12 holes eq. sp., B.C AA ,2 [8.00] 50,8 [2.00] 1 3/4-12 UNF-3B 76,2 [3.00] 1/2-20, 16 holes eq. sp., 6.50 B.C AA ,4 [11.00] 76,2 [3.00] 2 3/4-8 UNF-3B 114,3 [4.50] 5/8-18, 16 holes eq. sp., 9.00 B.C. 158 Questions? Contact us at either , Specifications subject to change.

17 Wiring codes Connector Unamplified A (+) excitation B (+) output C (-) output D (-) excitation E No connection F No connection Typical system diagram Deflections and ringing frequencies Capacity (lb) full scale (10-3 in) Natural ringing frequency (Hz) Weight g [lb] ,1 [3.1] ,1 [3.1] ,1 [3.1] ,5 [3.2] ,5 [3.2] ,6 [8.8] ,6 [8.8] [22] ,58 [55] Special requirements (consult factory) Have a special requirement? New diameter cable, different cable lengths, radiation proof, psi, output options, temperature settings, TEDS IEEE modules, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. Specifications subject to change. Questions? Contact us at either , 159

18 Model 47 Fatigue Rated Ultra Precision Universal Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: AL117 CV 6h Order codes AL117 Order code code Option code Model 47 fatigue rated ultra precision universal load cell CN 250 lb DW lb CR 500 lb EM lb 250 lb to lb Long fatigue life Accuracy up to 0.02 % Intrinsically safe available (2N option only) 12 CE approved 13 Notes 1. Static error band is the recommended performance specification. The static error band is calculated as the best fit straight line through zero, including the effects of non-linearity, hysteresis and non-repeatability. 2. Values noted are typical values but fall within the static error. 3. Allowable maximum loads maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 5. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal provides 50 % (unamplified units), 75 % (4 ma to 20 ma threewire units) or 80 % (voltage amplified units) of full scale output for quick calibration. Shunt calibration comes standard with internal amplifier option 2c, 2t and 2j. 6. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown; W=White; G=Green. Color specifying cable and number or letter specifying connector. 7. No mating connector necessary for cable option lb range has 700 ohm bridge resistance. 9. Off axis loading maximum allowable 50% full scale. 10. Internal amplifier for ranges less than lb may increase in height. 11. Consult factory for TEDS availability with amplified models. 12. dependent; consult factory. Termination dependent; consult factory. 13. Internal amp and termination dependent; consult factory. 14. This unit calibrated to Imperial (non-metric) units ohm bridge required. 16. Cannot be used with amplified option. 17. Cannot be used with options 1c, 1e, 1f, 1g, 1h, or 1i. CV DM DR Specifications Performance Load ranges lb 2500 lb 5000 lb 250 lb to lb Accuracy (static error band) 1,2 Linearity Hysteresis 250 lb to 1000 lb ±0.02 % full scale ±0.02 % full scale ±0.02 % full scale 2500 lb to 5000 lb ±0.03 % full scale ±0.03 % full scale ±0.04 % full scale lb to lb ±0.04 % full scale ±0.04 % full scale ±0.05 % full scale lb ±0.05 % full scale ±0.05 % full scale ±0.05 % full scale Non-repeatability ±0.01 % full scale Output 2.0 mv/v Tolerance on output ±1 % full scale Creep in 20 min. (max.) 0.01 % Environmental Temperature, operating -54 C to 93 C [-65 F to 200 F] Temperature, compensated -1 C to 54 C [30 F to 130 F] Temperature effect, zero % full scale/ F Temperature effect, span % reading/ F Strain gage type Foil Excitation (calibration) 10 Vdc Excitation (acceptable) 20 Vdc Insulation resistance V Bridge resistance 350 ohm (nominal) 8 Zero balance ±1 % full scale Shunt calibration data Included termination (std) PC02A-10-6P Mating connector (not incl.) PC06A-10-6S Mechanical Maximum allowable load 200 % FS 3, 9 Weight Case material Stainless steel Life cycles (approx.) > 10 8 cycles fully reversed Deflection Natural frequency EP ET lb lb 160 Questions? Contact us at either , Specifications subject to change.

19 Option codes Load ranges Temperature compensation Internal amplifiers 10 termination Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see honeywell.com/tmsensor-ship for updated listings. 250, 500, 1000, 2500, 5000, 12500, 25000, 50000, lb 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 1d. -20 F to 130 F 1e. -20 F to 200 F 1f. 70 F to 250 F 2b. ±5 Vdc 2c. 0 Vdc to 5 Vdc output 2j. 4 ma to 20 ma (three-wire) output 2k. 4 ma to 20 ma (two-wire) output 15 6a. Bendix PTIH-10-6P (or equivalent) 6-pin (max. 250 F) 6b. MS connector MS3102E-14S-6P (mates with MS S 6P) (max. 160 F) 17 6e. Integral cable: Teflon 6f. Integral cable: PVC 6g. Integral cable: Neoprene 6 Shunt calibration 8a. Precision internal resistor 16 1g. 70 F to 325 F 16 1h. 70 F to 400 F 16 1i. -65 F to 250 F 16 1j. 0 C to 50 C 1k. -20 C to 85 C 1m. -25 C to 110 C 2n (2N) 4 ma to 20 ma (two-wire) intrinsically safe 15 2t. 0 Vdc to 10 Vdc 2u. Unamplified, mv/v output 6h. Integral cable: Silicone 6i. Integral underwater cable 6j. 1/2-14 conduit fitting with 5 ft of 4 conductor PVC cable 6q. Molded integral cable: Polyurethane 6v. Phoenix connector on end of cable 15d. Connector on end of cable Special calibration 9a. 10 point (5 up/5 down) 20 % 70 F 9b. 20 point (10 up/10 down) 10 % 70 F 9c. ASTM E-74 calibration 9e. CE mark 30a. Compression only calibration, positive in compression 30b. Tension and compression calibration, positive in tension 30c. Compression only calibration, negative in compression 30d. Tension and compression calibration, positive in compression Bridge type 11a. Square bridge 16 11c. Square and symmetrical bridge 16 31a. Dual bridge Bridge resistance connector orientation 12b ohm (foil) (max. 250 F) 15a. Horizontal electrical exit port orientation 15b. Vertical electrical exit port orientation 15c. Radial electrical exit port orientation Internal amplifiers Amplifier specifications Output signal Input power (voltage) Input power (current) Freq. resp (amp) Power supply rej. Operating temp. Reverse voltage protection Short cir. protection Wiring code: connector (std) 5 Wiring code: cable 5,6,7 Voltage output: Option 2b Voltage output: Option 2c ±5 V 0 V to 5 V or ±5 45 ma ±15 V or 26 Vdc to 32 Vdc 11 Vdc to 28 Vdc Voltage output: Option 2t 0 V to 10 V or ±10 45 ma 15 Vdc to 28 Vdc Current three-wire: Option 2j 4 ma to 20 ma 22 Vdc to 32 Vdc Current two-wire: Option 2k 4 ma to 20 ma 15 Vdc to 40 Vdc 45 ma 40 ma 40 ma 65 ma 4 ma to 28 ma Intrinsically safe amp: Option 2n (2N)*** 4 ma to 20 ma 9 Vdc to 28 Vdc 4 ma to 24 ma 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz 60 db 60 db 60 db 60 db 60 db 60 db -20 F to 185 F -20 F to 185 F -20 F to 185 F 0 F to 185 F 0 F to 185 F -20 F to 185 F Yes Yes Yes Yes Yes Yes Momentary Momentary Momentary Yes Yes Yes B Output common C Supply return E Shunt cal 1 F Shunt cal 2 Bl Output common G Supply return W (+) Output B Shunt cal 1 Br Shunt cal 2 B Output common** C Supply return ** E Shunt cal 1 F Shunt cal 2 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 B Output common** C Supply return** E Shunt cal 1 F Shunt cal 2 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 B Output common** C Supply return** E Shunt cal 1 F Shunt cal 2 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 B No connection C No connection E Case ground F No connection Bl (+) Output W Case ground * Black and green wires are internally connected. ** Pins B and C are internally connected. *** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. # B No connection C No connection E Case ground F No connection Bl (+) Output W Case ground Shock and vibration 44a. Shock and vibration resistance Interfaces 53e. Signature calibration 16 53t. TEDS IEEE module 11 Specifications subject to change. Questions? Contact us at either , 161

20 Wiring codes Connector A B C D E F Unamplified (Std.) (+) excitation (+) output (-) output (-) excitation No connection No connection Mounting dimensions and characteristics s (lb) 250, 500, 1000, 2500, 5000 ØD1 mm 104,65 [4.12] 12500, ,92 [6.06] H mm 34,8 [1.37] 44,45 [1.75] T ØB mm 5/8-18 UNF-3B 34,0 [1.34] 1 1/4-12 UNF-3B 67,31 [2.65] N mm 3,05 [0.12] 3,05 [0.12] ØG mm 31,75 [1.25] 57,15 [2.25] Deflections and ringing frequencies Capacity (lb) full scale (10-3 in) Natural ringing frequency (Hz) Weight kg [lb] ,99 [6.6] ,99 [6.6] ,99 [6.6] ,04 [6.7] ,04 [6.7] ,98 [19.8] ,98 [19.8] ,05 [42] ,62 [116] Typical system diagram ,2 [8.00] 63,5 [2.50] 1 3/4-12 UNF-3B 95,50 [3.76] 6,35 [0.25] 76,2 [3.00] ,4 [11.00] 88,9 [3.50] 2 3/4-8 UNF-3B 122,17 [4.81] 12,7 [0.50] 114,3 [4.50] 162 Questions? Contact us at either , Specifications subject to change.

21 Model 3173 Tension/ Compression Pancake Load Cell English threads Enhanced accuracy Low deflection Fatigue resistant design and enhanced performance Low full-scale capacity Low profile Decreased sensitivity to extraneous loading Notes Model 3173 with tension base Model This unit calibrated to Imperial (non-metric) units. How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code and the desired load range in lbs. For example: Order code Order codes (lb) 3173 Model 3173 tension/compression pancake load cell Specifications Performance Load range 1 200, 500, 1K, 2K, 3K lb Non-linearity ±0.05 % of rated output Hysteresis ±0.05 % of rated output Repeatability ±0.02 % of rated output rated capacity (200 lb to 1K lb) 1.50 mv/v (nominal) rated capacity (2K lb to 3K lb) 2.00 mv/v (nominal) Creep ±0.025 % of rated output Operation Tension/compression Resolution Infinite Standard calibration Tension (+) and compression (-) Environmental Temperature, operating -54 C to 93 C [-65 F to 200 F] Temperature, compensated 21 C to 77 C [70 F to 170 F] Temperature effect, zero ±0.002 % of rated output/ F Temperature effect, output ±0.002 % of reading/ F Strain gage type Foil Excitation (maximum) 20 Vdc or Vac RMS Insulation resistance > Vdc Input resistance 700 ohm Output resistance 700 ohm Zero balance ±1.0 % termination PT02E-10-6P Mechanical Static overload capacity 150 % of nominal capacity Material Carbon steel Fatigue life (0 to full fatigue load) 100 x 10 6 cycles Fatigue life (full fatigue tension to compression) 50 x 10 6 cycles Natural frequency below Mechanical characteristics Nominal load limit capacity F z lb N Static overload capacity (% of nominal capacity) Static extraneous load limits Shear F X or F Y (lb) Bending M X or M Y (lb-in) Torque M Z (lb-in) Deflection at nominal load limit (in) 200 1K K K 5K K 10K K 15K Ringing frequency (Hz) Specifications subject to change. Questions? Contact us at either , 163

22 Output Input Serial Number SETUP LOAD CELLS Mounting dimensions and characteristics Model Capacity N [lb] A cm B cm C cm D cm E cm F cm G threads English H cm I cm No. of holes J Bolting screws K L cm M cm N cm O cm P cm Q cm K [200-3K] 10,47 [4.12] 7,24 [2.85] 3,23 [1.27] 3,48 [1.37] 0,31 [0.12] 0,15 [0.06] 5/8-18 UNF-3B 8.89 [3.5] 0,71 [0.28] 8 1/4-28 hexhead* 3,18 [1.25] 1,27 [0.50] 0,08 [0.03] 2,87 [1.13] 2,21 [0.87] 0,64 [0.25] * tighten to 200 in-lbs For reference only Wiring codes Typical system diagram Cable Red Black Green White (+) excitation (-) excitation (+) output (-) output In-Line Amplifiers (Used with unamplified units only) Amplifier Output Universal In-Line Amplifiers UV +/-5 VDC UV-10 +/-10 VDC UBP 0 +/-5 VDC U3W 4-20mA (3 wire) U2W 4-20mA (2 wire) DIN rail Mount In-Line Amplifiers DV /- 5 VDC (3 wire) DA mA (3 wire) DV10 0 +/- 10 VDC (3 wire) Customer Supplied Chart Recorder Alarm Panel Data Acquisition Computer PLC Power Supply Honeywell In-Line Amplifier Recommended Tension Base 064-LW MODEL 3173 Display Units SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH PSD OR lb. L1 L2 L3 L4 VALUE CLEAR CHAN TARE UP DOWN ENTER EXIT Mating Connectors & Cables 023-LW LF Mating Connector XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal) XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal) XX* Mating connector & 6 conductor cable (for connection to instrument 7541) XX** Mating connector & 4 conductor cable (for connection to instrument 7541) * XX represents length in feet 100ft maximum ** XX represents length in feet 20ft maximum 164 Questions? Contact us at either , Specifications subject to change.

23 Model 3174, 3175, 3176 Tension/ Compression Pancake Load Cell English threads Enhanced accuracy Low deflection Fatigue resistant design and enhanced performance Tension and compression capacity Low profile Low sensitivity to extraneous loading Notes Model 3174 with tension base Model This unit calibrated to Imperial (non-metric) units. How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code and the desired load range in lbs. For example: K Order code Order codes (lb) 3174 Model 3174 tension/compression pancake load cell, 5K, 10K, 20K lb 3175 Model 3175 tension/compression pancake load cell, 50K lb 3176 Model 3176 tension/compression pancake load cell, 100K lb Specifications Performance Load range 1 5K, 10K, 20K, 50K, 100K lb Non-linearity ±0.05 % of rated output Hysteresis ±0.05 % of rated output Repeatability ±0.02 % of rated output rated capacity 2.00 mv/v (nominal) Creep ±0.025 % of rated output Resolution Infinite Standard calibration Tension (+) and compression (-) Environmental Temperature, operating -54 C to 93 C [-65 F to 200 F] Temperature, compensated 21 C to 77 C [70 F to 170 F] Temperature effect, zero ±0.002 % of rated output/ F Temperature effect, output ±0.002 % of reading/ F Strain gage type Foil Excitation (maximum) 20 Vdc or Vac RMS Insulation resistance > Vdc Bridge resistance 700 ohm Number of bridges 1 Zero balance ±1.0 % termination PT02E-10-6P Mechanical Static overload capacity 150 % of nominal capacity Material Carbon steel Fatigue life (0 to full fatigue load) 100 x 10 6 cycles Fatigue life (full fatigue tension to compression) 50 x 10 6 cycles Natural frequency below Mechanical characteristics Nominal load limit capacity F z Model lb N Static overload capacity (% of nominal capacity) Fatigue capacity (% of nominal capacity) Static extraneous load limits Shear F X or F Y (lb) Bending M X or M Y (lb-in) Torque M Z (lb-in) Deflection at nominal load limit (in) K 20K K 9K 12K K 50K K 27K 24K K 100K K 58K 35K K 200K K 33K 67K K 500K K 147K 196K Ringing frequency (Hz) Specifications subject to change. Questions? Contact us at either , 165

24 Mounting dimensions and characteristics Model Capacity N [lb] A cm B cm C cm D cm E cm F cm G cm H cm Tap thru I English J cm K cm No. of holes L Bolting M English K-100K [5K-20K] 15,39 [6.06] 10,99 [4.33] 6,35 [2.42] 4,45 [1.75] 0,310 [0.12] 0,13 [0.05] 5,72 [2.25] 2,06 [0.81] 1¼-12 UNF-3B 13,02 [5.13] 10,3 [13/32] 12 3/8-24 hex head, 2¼ inches long, tighten to 750 in-lb K [50K] 20,32 [8.00] 13,15 [5.18] 7,98 [3.14] 6,35 [2.50] 0,30 [0.12] 0,08 [0.03] 7,98 [3.14] n/a 1¾-12 UN-3B 16,51 [6.50] 13,50 [17/32] 16 ½-20 hex head, 3 3/8 in long, tighten to 120 ft-lb, grade 8 bolts K [100K] 27,94 [11.00] 18,02 [7.09] 12,50 [4.92] 8,89 [3.50] 0,30 [0.12] 0,08 [0.03] 12,50 [4.92] n/a 2¾-8 UN-3B 22,86 [9.00] 16,70 [21/32] 16 5/8-18 hex head, 4 5/8 in long, tighten to 290 ft-lb, grade 8 bolts RECEP. PT02E-10-6P (MATING CONNECTOR FURNISHED) J BOLT CIRCLE THIS SURFACE FLAT TO INCH TIR AND FINISH TO 64 MAX MODEL 3174 ONLY A G 2.25 INCH 5.12 CM E I TAP THRU C DIA. K DIA. THRU L NUMBER OF HOLES EQUALLY SPACED M RECOMMENDED BOLTING SCREWS I TAP THRU H D F D Tension bases are recommended for all model 3174, 3175 and 3176 applications. When mounting without the tension base, attention must be given to the mating surface with regard to flatness, hardness and stiffness. F For reference only B DIA. A DIA. Wiring codes Cable Red Black Green White (+) excitation (-) excitation (+) output (-) output 166 Questions? Contact us at either , Specifications subject to change.

25 Output Input Serial Number Output Input Serial Number SETUP SETUP Output Input Serial Number SETUP LOAD CELLS Typical system diagram In-Line Amplifiers (Used with unamplified units only) Amplifier Output Universal In-Line Amplifiers UV ±5 Vdc UV-10 ±10 Vdc UBP 0 ±5 Vdc U3W 4-20mA (3 wire) U2W 4-20mA (2 wire) DIN rail Mount In-Line Amplifiers DV-05 0 ±5 Vdc (3 wire) DA mA (3 wire) DV10 0 ±10 Vdc (3 wire) Customer Supplied Chart Recorder Alarm Panel Data Acquisition Computer PLC Power Supply In-Line Amplifiers (Used with unamplified units only) Amplifier Output Universal In-Line Amplifiers UV ±5 Vdc UV-10 ±10 Vdc UBP 0 ±5 Vdc U3W 4-20mA (3 wire) U2W 4-20mA (2 wire) DIN rail Mount In-Line Amplifiers DV-05 0 ±5 Vdc (3 wire) DA mA (3 wire) DV10 0 ±10 Vdc (3 wire) Customer Supplied Chart Recorder Alarm Panel Data Acquisition Computer PLC Power Supply Honeywell In-Line Amplifier Honeywell In-Line Amplifier Recommended Tension Base 064-LW MODEL 3174 Display Units SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH PSD Recommended Tension Base 064-LW MODEL 3175 Display Units SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH PSD OR lb. L1 L2 L3 L4 OR lb. L1 L2 L3 L4 VALUE CLEAR CHAN TARE VALUE CLEAR CHAN TARE UP DOWN ENTER EXIT UP DOWN ENTER EXIT Mating Connectors & Cables Mating Connectors & Cables 023-LW LF Mating Connector XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal) XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal) XX* Mating connector & 6 conductor cable (for connection to instrument 7541) XX** Mating connector & 4 conductor cable (for connection to instrument 7541) * XX represents length in feet 100ft maximum ** XX represents length in feet 20ft maximum 023-LW LF Mating Connector XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal) XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal) XX* Mating connector & 6 conductor cable (for connection to instrument 7541) XX** Mating connector & 4 conductor cable (for connection to instrument 7541) * XX represents length in feet 100ft maximum ** XX represents length in feet 20ft maximum In-Line Amplifiers (Used with unamplified units only) Amplifier Output Universal In-Line Amplifiers UV ±5 Vdc UV-10 ±10 Vdc UBP 0 ±5 Vdc U3W 4-20mA (3 wire) U2W 4-20mA (2 wire) DIN rail Mount In-Line Amplifiers DV-05 0 ±5 Vdc (3 wire) DA mA (3 wire) DV10 0 ±10 Vdc (3 wire) Customer Supplied Chart Recorder Alarm Panel Data Acquisition Computer PLC Power Supply Honeywell In-Line Amplifier Recommended Tension Base 064-LW MODEL 3176 Display Units SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH PSD OR lb. L1 L2 L3 L4 VALUE CLEAR CHAN TARE UP DOWN ENTER EXIT Mating Connectors & Cables 023-LW LF Mating Connector XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal) XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal) XX* Mating connector & 6 conductor cable (for connection to instrument 7541) XX** Mating connector & 4 conductor cable (for connection to instrument 7541) * XX represents length in feet 100ft maximum ** XX represents length in feet 20ft maximum Specifications subject to change. Questions? Contact us at either , 167

26 A Output Input Serial Number VALUE CLEAR CHAN TARE UP DOWN SETUP ENTER EXIT LOAD CELLS Model 3149-FR Low Capacity Fatigue Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code and the desired load range in lbs. For example: 3149-FR 50 Order code (lbf) Order codes 3149-FR Model 3149-FR low capacity fatigue load cell Fatigue rated Miniature - only 2.75 in dia/1.5 in high Enhanced accuracy Options Additional bridges Output adjustment to standard value Integral cable Custom connectors Accessories Mating connector Loading fixtures Interconnect cable Shunt calibration resistor Instrumentation Notes 1. This unit calibrated to Imperial (non-metric) units. Mounting dimensions and characteristics OPTIONAL DUAL BRIDGE Specifications Performance Load range 1 50, 100, 300 lbf Zero balance ±1.0 % of rated output Non-linearity ±0.05 % of rated output Hysteresis ±0.05 % of rated output Non-repeatability ±0.01 % of rated output Static error band ±0.05 % of rated output Creep ±0.03 % (reading in 20 minutes) Environmental Temperature, operating -54 C to 93 C [-65 F to 200 F] Temperature, compensated -9 C to 46 C [15 F to 115 F] Temperature effect, sensitivity 0.08 % reading/100 F Temperature effect, zero 0.15 % of rated output/100 F Excitation (recommended) 10 Vdc Input resistance 700 ohm, +40/-3.5 ohm Output resistance 700 ohm ±3.5 ohm Sensitivity (rated output) 2 mv/v (nominal) Insulation resistance, bridge/case Vdc Mechanical Safe overload range 150 % of rated output Weight 0.8 lb Flexure material Aluminum Typical system diagram In-Line Amplifiers (Used with unamplified units only) Amplifier Output Universal In-Line Amplifiers UV +/-5 VDC UV-10 +/-10 VDC UBP 0 +/-5 VDC U3W 4-20mA (3 wire) U2W 4-20mA (2 wire) DIN rail Mount In-Line Amplifiers DV /- 5 VDC (3 wire) DA mA (3 wire) DV10 0 +/- 10 VDC (3 wire) Customer Supplied Chart Recorder Alarm Panel Data Acquisition Computer PLC Power Supply 2.56 R Honeywell In-Line Amplifier 2.36 Display Units Ø2.75 MODEL 3149FR SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH PSD Ø PLACES Mating Connectors & Cables lb. OR L1 L2 L3 L4 For reference only 0.03, 2 PLACES /4-28 UNF, 0.28 DEEP, 2 PLACES [FOR METRIC VERSION: m6 X 1.0, 7.1 DEEP, 2 PLACES] 023-LW LF Mating Connector XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal) XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal) XX* Mating connector & 6 conductor cable (for connection to instrument 7541) XX** Mating connector & 4 conductor cable (for connection to instrument 7541) * XX represents length in feet 100ft maximum ** XX represents length in feet 20ft maximum 168 Questions? Contact us at either , Specifications subject to change.

27 Model 3108 Tension/ Compression Pancake Load Cell 5 lb to 10 lb range Calibration traceable to the National Bureau of Standards Low sensitivity to extraneous loads Low deflection Barometrically compensated construction Built-in temperature compensation Circuitry designed to provide true temperature compensation Notes 1. This unit calibrated to Imperial (non-metric) units. How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code and the desired load range in lbs. For example: Order code Order codes (lb) 3108 Model 3108 tension/compression pancake load cell Specifications Performance Load range 1 5, 10 lb Non-linearity ±0.01 % of rated output Hysteresis ±0.01 % of rated output Repeatability ±0.05 % of rated output rated capacity 2 mv/v ±0.25 % (nominal) Operation Tension/compression Resolution Infinite Standard calibration Tension (+) and compression (-) Environmental Temperature, operating -54 C to 93 C [-65 F to 200 F] Temperature, compensated 21 C to 77 C [70 F to 170 F] Temperature effect, zero ±0.002 % of rated output/ F Temperature effect, output ±0.002 % of reading/ F Strain gage type Foil Excitation (maximum) 20 Vdc or Vac RMS Insulation resistance > Vdc Bridge resistance (tolerance) 350 ohm Number of bridges 1 or 2 Zero balance ±1.0 % termination PT02E-10-6P mates with PT06W-10-6S Mechanical Static overload capacity 150 % of nominal capacity Material Carbon steel Natural frequency below Mechanical characteristics Nominal load limit capacity F z lb N Static overload capacity (% of nominal capacity) Static extraneous load limits Shear F X or F Y (lb) Bending M X or M Y (lb-in) Torque M Z (lb-in) Deflection at nominal load limit (in) Ringing frequency (Hz) Specifications subject to change. Questions? Contact us at either , 169

28 Output Input Serial Number SETUP LOAD CELLS Mounting dimensions and characteristics Wiring codes Model A cm B cm C cm D cm E cm F cm ,98 [2.75] 0,55 [0.22] 0,32 [0.13] 4,44 [1.75] 5,60 [2.22] - [1/4-28] G cm H cm J cm K cm L cm N cm P cm 1,27 [0.38] 1,10 [0.44] 0,71 [0.28] 3,80 [1.50] 0,16 [0.06] 4,13 [1.63] 2,54 [1.00] NOTE: the 3108 mounting configuration is similar to the Cable Red Black Green White (+) excitation (-) excitation (+) output (-) output F THD. G DEEP BOTH ENDS DUAL BRIDGE OPTIONAL E A SPANNER WRENCH HOLE B DIA. C DEEP RECEP. PTO2E-10-6P Typical system diagram In-Line Amplifiers (Used with unamplified units only) Amplifier Output Universal In-Line Amplifiers UV +/-5 VDC UV-10 +/-10 VDC UBP 0 +/-5 VDC U3W 4-20mA (3 wire) U2W 4-20mA (2 wire) DIN rail Mount In-Line Amplifiers DV /- 5 VDC (3 wire) DA mA (3 wire) DV10 0 +/- 10 VDC (3 wire) Honeywell In-Line Amplifier Customer Supplied Chart Recorder Alarm Panel Data Acquisition Computer PLC Power Supply D Display Units C H DIA. J MODEL 3108 SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH PSD OR lb. L1 L2 L3 L4 VALUE CLEAR CHAN TARE UP DOWN ENTER EXIT P K Mating Connectors & Cables For reference only N DIA. L 023-LW LF Mating Connector XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal) XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal) XX* Mating connector & 6 conductor cable (for connection to instrument 7541) XX** Mating connector & 4 conductor cable (for connection to instrument 7541) * XX represents length in feet 100ft maximum ** XX represents length in feet 20ft maximum 170 Questions? Contact us at either , Specifications subject to change.

29 Model 3397 Tension/ Compression Pancake Load Cell 25 lb to 300 lb range Calibration traceable to the National Bureau of Standards Low sensitivity to extraneous loads Low deflection Barometrically compensated construction Built-in temperature compensation Circuitry designed to provide true temperature compensation Notes 1. This unit calibrated to Imperial (non-metric) units. How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code and the desired load range in lbs. For example: Order code Order codes (lb) 3397 Model 3397 tension/compression pancake load cell Specifications Performance Load range 1 25 lb, 50 lb, 100 lb, 200 lb, 300 lb Non-linearity ±0.05 % of rated output Hysteresis ±0.05 % of rated output Repeatability ±0.02 % of rated output rated capacity 2 mv/v ±0.25 % (nominal) Operation Tension/compression Resolution Infinite Standard calibration Tension (+) and compression (-) Environmental Temperature, operating -54 C to 93 C [-65 F to 200 F] Temperature, compensated 21 C to 77 C [70 F to 170 F] Temperature effect, zero ±0.002 % of rated output/ F Temperature effect, output ±0.002 % of reading/ F Strain gage type Foil Excitation (maximum) 20 Vdc or Vac RMS Insulation resistance > Vdc Bridge resistance (tolerance) 350 ohm Number of bridges 1 or 2 Zero balance ±1.0 % termination PT02E-10-6P mates with PT06W-10-6S Mechanical Static overload capacity 150 % of nominal capacity Material Carbon steel Natural frequency below Mechanical characteristics Nominal load limit capacity F z lb N Static overload capacity (% of nominal capacity) Static extraneous load limits Shear F X or F Y (lb) Bending M X or M Y (lb-in) Torque M Z (lb-in) Deflection at nominal load limit (in) K K Ringing frequency (Hz) Specifications subject to change. Questions? Contact us at either , 171

30 Output Input Serial Number SETUP LOAD CELLS Mounting dimensions and characteristics Wiring codes Model A cm B cm C cm D cm E cm F cm ,98 [2.75] 0,55 [0.22] 0,32 [0.13] 4,44 [1.75] 5,60 [2.22] - [1/4-28] G cm H cm J cm K cm L cm N cm P cm 1,27 [0.50] 1,10 [0.44] 0,24 [0.09] 3,80 [1.50] 0,16 [0.06] 4,44 [1.75] 2,54 [1.00] Cable Red Black Green White (+) excitation (-) excitation (+) output (-) output F THD. G DEEP BOTH ENDS DUAL BRIDGE OPTIONAL E A SPANNER WRENCH HOLE B DIA. C DEEP RECEP. PTO2E-10-6P Typical system diagram In-Line Amplifiers (Used with unamplified units only) Amplifier Output Universal In-Line Amplifiers UV +/-5 VDC UV-10 +/-10 VDC UBP 0 +/-5 VDC U3W 4-20mA (3 wire) U2W 4-20mA (2 wire) DIN rail Mount In-Line Amplifiers DV /- 5 VDC (3 wire) DA mA (3 wire) DV10 0 +/- 10 VDC (3 wire) Customer Supplied Chart Recorder Alarm Panel Data Acquisition Computer PLC Power Supply Honeywell In-Line Amplifier D Display Units C H DIA. J MODEL 3397 SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH PSD P K OR lb. L1 L2 L3 L4 VALUE CLEAR CHAN TARE UP DOWN ENTER EXIT For reference only N DIA. L Mating Connectors & Cables 023-LW LF Mating Connector XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal) XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal) XX* Mating connector & 6 conductor cable (for connection to instrument 7541) XX** Mating connector & 4 conductor cable (for connection to instrument 7541) * XX represents length in feet 100ft maximum ** XX represents length in feet 20ft maximum 172 Questions? Contact us at either , Specifications subject to change.

31 Model 3167 Tension/ Compression Pancake Load Cell 25 lb to 300 lb range Calibration traceable to the National Bureau of Standards Low sensitivity to extraneous loads Low deflection Barometrically compensated construction Built-in temperature compensation Circuitry designed to provide true temperature compensation Notes 1. This unit calibrated to Imperial (non-metric) units. How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code and the desired load range in lbs. For example: Order code Order codes (lb) 3167 Model 3167 tension/compression pancake load cell Specifications Performance Load range 1 25, 50, 100, 200, 300 lb Non-linearity ±0.05 % of rated output Hysteresis ±0.05 % of rated output Repeatability ±0.02 % of rated output rated capacity 2 mv/v (nominal) Operation Tension/compression Resolution Infinite Standard calibration Tension (+) and compression (-) Environmental Temperature, operating -54 C to 93 C [-65 F to 200 F] Temperature, compensated 21 C to 77 C [70 F to 170 F] Temperature effect, zero ±0.002 % of rated output/ F Temperature effect, output ±0.002 % of reading/ F Strain gage type Foil Excitation (maximum) 20 Vdc or Vac RMS Insulation resistance > Vdc Bridge resistance (tolerance) 350 ohm Number of bridges 1 Zero balance ±5.0 % termination 15 ft of Belden 8723 four-conductor shielded cable Mechanical Static overload capacity 150 % of nominal capacity Material Carbon steel Natural frequency below Mechanical characteristics Nominal load limit capacity F z lb N Static overload capacity (% of nominal capacity) Static extraneous load limits Shear F X or F Y (lb) Bending M X or M Y (lb-in) Torque M Z (lb-in) Deflection at nominal load limit (in) K K Ringing frequency (Hz) Specifications subject to change. Questions? Contact us at either , 173

32 Output Input Serial Number SETUP LOAD CELLS Mounting dimensions and characteristics Wiring codes Model A cm B cm C cm D cm E cm ,72 [2.25] - [1/4-28] 0,95 [0.38] 1,10 [0.44] 1,10 [0.44] F cm G cm H cm J cm K cm 0,24 [0.09] 3,80 [1.50] 0,16 [0.06] 4,44 [1.75] 6,98 [2.75] Cable Red Black Green White (+) excitation (-) excitation (+) output (-) output B UNF THD. C DEEP BOTH ENDS Typical system diagram FOUR COND. SHIELD CABLE BELDEN FEET A +/- H In-Line Amplifiers (Used with unamplified units only) Amplifier Output Universal In-Line Amplifiers UV +/-5 VDC UV-10 +/-10 VDC UBP 0 +/-5 VDC U3W 4-20mA (3 wire) U2W 4-20mA (2 wire) DIN rail Mount In-Line Amplifiers DV /- 5 VDC (3 wire) DA mA (3 wire) DV10 0 +/- 10 VDC (3 wire) Honeywell In-Line Amplifier Customer Supplied Chart Recorder Alarm Panel Data Acquisition Computer PLC Power Supply Display Units E F SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH PSD MODEL 3167 D G OR UP DOWN lb. L1 L2 L3 L4 VALUE CLEAR CHAN TARE ENTER EXIT J DIA. H For reference only K DIA. 174 Questions? Contact us at either , Specifications subject to change.

33 Model 3132 Tension/ Compression Pancake Load Cell 500 lb to 5000 lb range Calibration traceable to the National Bureau of Standards Low sensitivity to extraneous loads Low deflection Rugged welded construction Built-in temperature compensation Circuitry designed to provide true temperature compensation Notes 1. This unit calibrated to Imperial (non-metric) units. How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code and the desired load range in lbs. For example: Order code Order codes (lb) 3132 Model 3132 tension/compression pancake load cell Specifications Performance Load range 1 500, 1000, 2000, 3000, 5000 lb Non-linearity ±0.1 % of rated output Hysteresis ±0.1 % of rated output Repeatability ±0.05 % of rated output rated capacity 3 mv/v ±0.25 % (nominal) Operation Tension/compression Resolution Infinite Standard calibration Tension (+) and compression (-) Environmental Temperature, operating -54 C to 93 C [-65 F to 200 F] Temperature, compensated 21 C to 77 C [70 F to 170 F] Temperature effect, zero ±0.002 % of rated output/ F Temperature effect, output ±0.002 % of reading/ F Strain gage type Foil Excitation (maximum) 20 Vdc or Vac RMS Insulation resistance > Vdc Bridge resistance (tolerance) 350 ohm Number of bridges 1 or 2 Zero balance ±1.0 % termination PT02E-10-6P mates with PT06W-10-6S Mechanical Static overload capacity 150 % of nominal capacity Material Carbon steel Natural frequency below Mechanical characteristics Nominal load limit capacity F z lb N Static overload capacity (% of nominal capacity) Static extraneous load limits Shear F X or F Y (lb) Bending M X or M Y (lb-in) Torque M Z (lb-in) Deflection at nominal load limit (in) 500 2K K 5K K 10K K 15K K 20K Ringing frequency (Hz) Specifications subject to change. Questions? Contact us at either , 175

34 SETUP LOAD CELLS Mounting dimensions and characteristics Model A cm B cm C cm D cm E cm F cm G cm H cm J cm K cm L cm ,65 [2.62] 1,60 [0.63] 8,89 [3.50] 2,54 [1.0] 3,02 [1.19] 4,45 [1.75] 0,64 [0.25] 8,70 [0.34] 5,08 [2.0] 3,33 [1.31] 2,54 [1.0] Typical system diagram For reference only Wiring codes Cable Red (+) excitation Black (-) excitation Green (+) output White (-) output In-Line Amplifiers (Used with unamplified units only) Amplifier Output Universal In-Line Amplifiers UV +/-5 VDC UV-10 +/-10 VDC UBP 0 +/-5 VDC U3W 4-20mA (3 wire) U2W 4-20mA (2 wire) DIN rail Mount In-Line Amplifiers DV /- 5 VDC (3 wire) DA mA (3 wire) DV10 0 +/- 10 VDC (3 wire) MODEL 3132 Honeywell In-Line Amplifier Output Serial Number Input Display Units Customer Supplied Chart Recorder Alarm Panel Data Acquisition Computer PLC Power Supply SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH PSD OR lb. L1 L2 L3 L4 VALUE CLEAR CHAN TARE UP DOWN ENTER EXIT Mating Connectors & Cables 023-LW LF Mating Connector XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal) XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal) XX* Mating connector & 6 conductor cable (for connection to instrument 7541) XX** Mating connector & 4 conductor cable (for connection to instrument 7541) * XX represents length in feet 100ft maximum ** XX represents length in feet 20ft maximum 176 Questions? Contact us at either , Specifications subject to change.

35 Model 3140-P Series Tension/ Compression Pancake Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code and the desired load range in lbs. For example: 3143-P 2K Order code Order code (lb) 3143-P Model 3140 series tension/compression pancake load cell, 300 lb to 2000 lb 3144-P Model 3140 series tension/compression pancake load cell, 5000 lb to lb 3145-P Model 3140 series tension/compression pancake load cell, lb to lb 3146-P Model 3140 series tension/compression pancake load cell, lb Enhanced accuracy version of standard 3140 Series Low height Smaller guaranteed maximum offcenter load and moment error than standard 3140 Series Static error band 0.02 % to 0.04 % Low creep Low sensitivity to magnetic fields Barometric pressure compensated Temperature compensated Output to 4 mv/v Notes 1. This unit calibrated to Imperial (non-metric) units. Specifications Performance Load range 1 Non-linearity 300 lb to 2K lb ±0.02 % of rated output 5K lb to 100K lb ±0.04 % of rated output Hysteresis ±0.02 % of rated output Non-repeatability ±0.01 % of rated output Static error band 300 lb to 2K lb ±0.02 % of rated output 5K lb to 10K lb ±0.03 % of rated output 25K lb to 100K lb ±0.04 % of rated output rated capacity 4 mv/v (nominal) Operation Tension/compression Resolution Infinite Standard calibration Tension (+) and compression (-) Environmental Temperature, operating -54 C to 93 C [-65 F to 200 F] Temperature, compensated -9 C to 46 C [15 F to 115 F] Temperature effect, zero ±0.008 % of rated output/100 F Temperature effect, output ±0.008 % of reading/100 F Strain gage type Foil Excitation (maximum) 10 Vdc or Vac RMS Insulation resistance > Vdc Input resistance (tolerance) 350 ohm +40/-3.5 ohm Output resistance (tolerance) 350 ohm ±3.5 ohm Sensitivity 300 lb to 2K lb 2 mv/v of rated output 5K lb to 100K lb 4 mv/v of rated output Zero balance (tolerance) ±1.0 % Mechanical Static overload capacity 150 % of nominal capacity Material on next page Creep ±0.03 % 300 lb, 500 lb, 1000 lb, 2000 lb, 5000 lb, lb, lb, lb, lb Specifications subject to change. Questions? Contact us at either , 177

36 Mounting dimensions and characteristics Model Capacity (lb) Ø A in Ø B in C in D in E Thread F in G in Ø H J in K Thread L in 3143-P /2-20 UNF 3B /2-20 UNF 3B P /2-20 UNF 3B /2-20 UNF 3B P-1K /2-20 UNF 3B /2-20 UNF 3B P-2K /2-20 UNF 3B /2-20 UNF 3B P-5K /8-18 UNF 3B /8-18 UNF 3B P-10K /8-18 UNF 3B /8-18 UNF 3B P-25K ¼-12 UNF 3B ¼-12 UNF 3B P-50K ¼-12 UNF 3B ¼-12 UNF 3B P-100K ¾-12 UNF 3B ¾-12 UNF 3B 1.75 PT02E-10-6P CONNECTOR D J Wiring codes Cable Red (+) excitation Ø A Ø B Ø H Black (-) excitation Green (+) output White (-) output For reference only E THD. F DEEP C G K THD. L DEEP Mechanical characteristics Nominal load limit capacity F z Model lb N Static overload capacity (% of nominal capacity) Weight (lb) Weight with base (lb) Flexure material 3143-P 300 1K Aluminum 3143-P 500 2K Aluminum 3143-P 1K 5K Aluminum 3143-P 2K 10K Aluminum 3144-P 5K 22K Steel 3144-P 10K 45K Steel 3145-P 25K 110K Steel 3145-P 50K 200K Steel 3146-P 100K 500K Steel 178 Questions? Contact us at either , Specifications subject to change.

37 Output Input Serial Number Output Input Serial Number SETUP SETUP Output Input Serial Number Output Input Serial Number SETUP SETUP LOAD CELLS Typical system diagram In-Line Amplifiers (Used with unamplified units only) Amplifier Output Universal In-Line Amplifiers UV +/-5 VDC UV-10 +/-10 VDC UBP 0 +/-5 VDC U3W 4-20mA (3 wire) U2W 4-20mA (2 wire) DIN rail Mount In-Line Amplifiers DV /- 5 VDC (3 wire) DA mA (3 wire) DV10 0 +/- 10 VDC (3 wire) Customer Supplied Chart Recorder Alarm Panel Data Acquisition Computer PLC Power Supply In-Line Amplifiers (Used with unamplified units only) Amplifier Output Universal In-Line Amplifiers UV +/-5 VDC UV-10 +/-10 VDC UBP 0 +/-5 VDC U3W 4-20mA (3 wire) U2W 4-20mA (2 wire) DIN rail Mount In-Line Amplifiers DV /- 5 VDC (3 wire) DA mA (3 wire) DV10 0 +/- 10 VDC (3 wire) Customer Supplied Chart Recorder Alarm Panel Data Acquisition Computer PLC Power Supply Honeywell In-Line Amplifier Honeywell In-Line Amplifier Display Units Display Units MODEL 3143P SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH PSD SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH PSD MODEL 3144P OR lb. L1 L2 L3 L4 OR lb. L1 L2 L3 L4 VALUE CLEAR CHAN TARE VALUE CLEAR CHAN TARE UP DOWN ENTER EXIT UP DOWN ENTER EXIT Mating Connectors & Cables Mating Connectors & Cables 023-LW LF Mating Connector XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal) XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal) XX* Mating connector & 6 conductor cable (for connection to instrument 7541) XX** Mating connector & 4 conductor cable (for connection to instrument 7541) * XX represents length in feet 100ft maximum ** XX represents length in feet 20ft maximum 023-LW LF Mating Connector XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal) XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal) XX* Mating connector & 6 conductor cable (for connection to instrument 7541) XX** Mating connector & 4 conductor cable (for connection to instrument 7541) * XX represents length in feet 100ft maximum ** XX represents length in feet 20ft maximum In-Line Amplifiers (Used with unamplified units only) Amplifier Output Universal In-Line Amplifiers UV +/-5 VDC UV-10 +/-10 VDC UBP 0 +/-5 VDC U3W 4-20mA (3 wire) U2W 4-20mA (2 wire) DIN rail Mount In-Line Amplifiers DV /- 5 VDC (3 wire) DA mA (3 wire) DV10 0 +/- 10 VDC (3 wire) Customer Supplied Chart Recorder Alarm Panel Data Acquisition Computer PLC Power Supply In-Line Amplifiers (Used with unamplified units only) Amplifier Output Universal In-Line Amplifiers UV +/-5 VDC UV-10 +/-10 VDC UBP 0 +/-5 VDC U3W 4-20mA (3 wire) U2W 4-20mA (2 wire) DIN rail Mount In-Line Amplifiers DV /- 5 VDC (3 wire) DA mA (3 wire) DV10 0 +/- 10 VDC (3 wire) Customer Supplied Chart Recorder Alarm Panel Data Acquisition Computer PLC Power Supply Honeywell In-Line Amplifier Honeywell In-Line Amplifier Display Units SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH PSD Display Units SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH PSD MODEL 3145P MODEL 3146P OR lb. L1 L2 L3 L4 OR lb. L1 L2 L3 L4 VALUE CLEAR CHAN TARE VALUE CLEAR CHAN TARE UP DOWN ENTER EXIT UP DOWN ENTER EXIT Mating Connectors & Cables Mating Connectors & Cables 023-LW LF Mating Connector XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal) XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal) XX* Mating connector & 6 conductor cable (for connection to instrument 7541) XX** Mating connector & 4 conductor cable (for connection to instrument 7541) * XX represents length in feet 100ft maximum ** XX represents length in feet 20ft maximum 023-LW LF Mating Connector XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal) XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal) XX* Mating connector & 6 conductor cable (for connection to instrument 7541) XX** Mating connector & 4 conductor cable (for connection to instrument 7541) * XX represents length in feet 100ft maximum ** XX represents length in feet 20ft maximum Specifications subject to change. Questions? Contact us at either , 179

38 Model 3140-CS Series Tension/ Compression Pancake Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code and the desired load range in lbs. For example: 3143-CS 2K Order code Order codes (lb) 3143-CS Model 3140 series tension/compression pancake load cell, 300 lb to 2000 lb 3144-CS Model 3140 series tension/compression pancake load cell, 5000 lb to lb 3145-CS Model 3140 series tension/compression pancake load cell, lb to lb 3146-CS Model 3140 series tension/compression pancake load cell, lb Specifications Performance Load range 1 300, 500, 1000, 2000, 5000, 10000, 25000, 50000, lb to 2K lb 5K lb to 10K lb 25K lb to 100K lb 300 lb to lb range Universal tension and compression loading Enhanced accuracy Low profile 150 % full scale safe overload capability Available in single or optional dual bridge configuration Metric sizes available Factory installed calibration adapters Eccentric load compensated High precision base installed Notes 1. This unit calibrated to Imperial (non-metric) units. Non-linearity error (of full scale) ±0.02 % ±0.04 % ±0.04 % Hysteresis error (of full scale) ±0.02 % ±0.04 % ±0.05 % Non-repeatability (of full scale) ±0.005 % ±0.005 % ±0.005 % rated capacity (nominal) 2.0 mv/v 4.0 mv/v 4.0 mv/v Operation Tension/compression Resolution Infinite Standard calibration Tension (+) and compression (-) Environmental Temperature, operating -54 C to 93 C [-65 F to 200 F] Temperature, compensated -9 C to 46 C [15 F to 115 F] Temperature effect, zero 0.08 % of rated output/100 F Temperature effect, output 0.08 % of reading/100 F Strain gage type Foil Excitation (maximum) 10 Vdc or Vac RMS Insulation resistance > Vdc Input resistance (tolerance) 350 ohm ±40/-3.5 ohm Output resistance (tolerance) 350 ohm ±3.5 ohm Zero balance (tolerance) ±1.0 % termination PT02E-10-6P mates with PT06W-10-6S Mechanical Static overload capacity 150 % of nominal capacity Material Carbon steel Creep ±0.01 % Off-centered load sensitivity 300 lb to 2K lb ±0.10 % 5K lb to 100K lb ±0.25 % Side load sensitivity 300 lb to 2K lb ±0.10 % 5K lb to 100K lb ±0.25 % 180 Questions? Contact us at either , Specifications subject to change.

39 Mounting dimensions and characteristics Model Capacity (lb) Ø A in B in C in D in E in F in G in Ø H in J Thread Ø K in L Thread M in CS /2-20 UNF 3A /2-20 UNF 3B CS /2-20 UNF 3A /2-20 UNF 3B CS-1K /2-20 UNF 3A /2-20 UNF 3B CS-2K /2-20 UNF 3A /2-20 UNF 3B CS-5K /8-18 UNF 3A /8-18 UNF 3B CS-10K /8-18 UNF 3A /8-18 UNF 3B CS-25K ¼-12 UNF 3A ¼-12 UNF 3B CS-50K ¼-12 UNF 3A ¼-12 UNF 3B CS-100K ¾-12 UNF 3A ¾-12 UNF 3B 1.75 RECEP. PT02E-10-6P F E Wiring codes D G Cable Ø K R Red (+) excitation Black (-) excitation Ø A Ø H Green (+) output White (-) output J THD. B C L THD. M DEEP For reference only Specifications subject to change. Questions? Contact us at either , 181

40 Output Input Serial Number Output Input Serial Number SETUP SETUP Output Input Serial Number Output Input Serial Number SETUP SETUP LOAD CELLS Typical system diagrams In-Line Amplifiers (Used with unamplified units only) Amplifier Output Universal In-Line Amplifiers UV +/-5 VDC UV-10 +/-10 VDC UBP 0 +/-5 VDC U3W 4-20mA (3 wire) U2W 4-20mA (2 wire) DIN rail Mount In-Line Amplifiers DV /- 5 VDC (3 wire) DA mA (3 wire) DV10 0 +/- 10 VDC (3 wire) Customer Supplied Chart Recorder Alarm Panel Data Acquisition Computer PLC Power Supply In-Line Amplifiers (Used with unamplified units only) Amplifier Output Universal In-Line Amplifiers UV +/-5 VDC UV-10 +/-10 VDC UBP 0 +/-5 VDC U3W 4-20mA (3 wire) U2W 4-20mA (2 wire) DIN rail Mount In-Line Amplifiers DV /- 5 VDC (3 wire) DA mA (3 wire) DV10 0 +/- 10 VDC (3 wire) Customer Supplied Chart Recorder Alarm Panel Data Acquisition Computer PLC Power Supply Honeywell In-Line Amplifier Honeywell In-Line Amplifier Display Units Display Units MODEL 3143CS SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH PSD MODEL 3144CS SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH PSD OR lb. L1 L2 L3 L4 OR lb. L1 L2 L3 L4 VALUE CLEAR CHAN TARE VALUE CLEAR CHAN TARE UP DOWN ENTER EXIT UP DOWN ENTER EXIT Mating Connectors & Cables Mating Connectors & Cables 023-LW LF Mating Connector XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal) XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal) XX* Mating connector & 6 conductor cable (for connection to instrument 7541) XX** Mating connector & 4 conductor cable (for connection to instrument 7541) * XX represents length in feet 100ft maximum ** XX represents length in feet 20ft maximum 023-LW LF Mating Connector XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal) XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal) XX* Mating connector & 6 conductor cable (for connection to instrument 7541) XX** Mating connector & 4 conductor cable (for connection to instrument 7541) * XX represents length in feet 100ft maximum ** XX represents length in feet 20ft maximum In-Line Amplifiers (Used with unamplified units only) Amplifier Output Universal In-Line Amplifiers UV +/-5 VDC UV-10 +/-10 VDC UBP 0 +/-5 VDC U3W 4-20mA (3 wire) U2W 4-20mA (2 wire) DIN rail Mount In-Line Amplifiers DV /- 5 VDC (3 wire) DA mA (3 wire) DV10 0 +/- 10 VDC (3 wire) Customer Supplied Chart Recorder Alarm Panel Data Acquisition Computer PLC Power Supply In-Line Amplifiers (Used with unamplified units only) Amplifier Output Universal In-Line Amplifiers UV +/-5 VDC UV-10 +/-10 VDC UBP 0 +/-5 VDC U3W 4-20mA (3 wire) U2W 4-20mA (2 wire) DIN rail Mount In-Line Amplifiers DV /- 5 VDC (3 wire) DA mA (3 wire) DV10 0 +/- 10 VDC (3 wire) Customer Supplied Chart Recorder Alarm Panel Data Acquisition Computer PLC Power Supply Honeywell In-Line Amplifier Honeywell In-Line Amplifier Display Units Display Units MODEL 3145CS SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH PSD MODEL 3146CS SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH PSD OR lb. L1 L2 L3 L4 OR lb. L1 L2 L3 L4 VALUE CLEAR CHAN TARE VALUE CLEAR CHAN TARE UP DOWN ENTER EXIT UP DOWN ENTER EXIT Mating Connectors & Cables Mating Connectors & Cables 023-LW LF Mating Connector XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal) XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal) XX* Mating connector & 6 conductor cable (for connection to instrument 7541) XX** Mating connector & 4 conductor cable (for connection to instrument 7541) * XX represents length in feet 100ft maximum ** XX represents length in feet 20ft maximum 023-LW LF Mating Connector XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal) XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal) XX* Mating connector & 6 conductor cable (for connection to instrument 7541) XX** Mating connector & 4 conductor cable (for connection to instrument 7541) * XX represents length in feet 100ft maximum ** XX represents length in feet 20ft maximum 182 Questions? Contact us at either , Specifications subject to change.

41 Model 43 Precision Low Profile Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: AL112 CV 6h Order codes AL112 Order code code Option code Model 43 precision low profile load cell 5 lb to lb mv/v output Stainless steel Double diaphragm design 0.10 % accuracy AT AV BL BN BR CN CR CV DL DN DP DR DT 5 lb 10 lb 25 lb 50 lb 100 lb 250 lb 500 lb 1000 lb 2000 lb 3000 lb 4000 lb 5000 lb 7500 lb DV EJ EL EN EP ER ET FJ FL FN FP FR lb lb lb lb lb lb lb lb lb lb lb lb Notes mm [3.00 in] diameter has six mounting holes. 2. Allowable maximum loads - maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 4. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal provides 50 % (unamplified units), 75 % (4 ma to 20 ma threewire units) or 80 % (voltage amplified units) of full scale output for quick calibration. Shunt calibration comes standard with internal amplifier option 2a, 2b, 2c, 2t and 2j. 5. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown; W=White; G=Green. Color specifying cable and number or letter specifying connector 6. No mating connector necessary for cable option. 7. Only available with option 2a or 2c. 8. Consult factory for TEDS availability with amplified models. 9. This unit calibrated to Imperial (non-metric) units ohm bridge required. 11. Cannot be used with amplified option. 12. Cannot be used with options 1c, 1e, 1f, 1g, 1h, or 1i. Approved Approved Approved Intrinsically safe amp Specifications Performance Load ranges 9 5 lb to lb Non-linearity, 5 lb to 25 lb ±0.2 % full scale Non-linearity, 50 lb to lb ±0.1 % full scale Hysteresis, 5 lb to 25 lb ±0.1 % full scale Hysteresis, 50 lb to lb ±0.08 % full scale Non-repeatability, 5 lb to 25 lb ±0.1 % full scale Non-repeatability, 50 lb to lb ±0.03 % full scale Output (tolerance), 5 lb to 25 lb 2 mv/v ±0.5 % full scale Output (tolerance), 50 lb to lb 3 mv/v ±0.5 % full scale Operation Compression Resolution Infinite Standard calibration 5 point calibration, compression only Environmental Temperature, operating -54 C to 121 C [-65 F to 250 F] Temperature, compensated 15 C to 71 C [60 F to 160 F] Temperature effect, zero % full scale/ F Temperature effect, span % full scale/ F Strain gage type Bonded foil Excitation (calibration) 10 Vdc Excitation (acceptable) Up to 15 Vdc or Vac Insulation resistance Vdc Bridge resistance (tolerance) 350 ohm Zero balance (tolerance) ±1 % full scale Shunt calibration data Included termination (std) 5 lb to 5000 lb PTIH-10-6P 7500 lb to lb MS3106E-14S-6P Mating connector (not included) 5 lb to 5000 lb PT06A-10-6S or equiv. (AA111) 7500 to lb MS3106A-14S-6S (AA121) Mechanical Maximum allowable load 150 % FS 2 Weight Material 17-4PH Stainless Steel Life cycle (approx.) > 10 million cycles Deflection Natural frequency Specifications subject to change. Questions? Contact us at either , 183

42 Wiring codes Internal amplifiers Connector A B C D Unamplified (Std.) (+) excitation (+) excitation (-) excitation (-) excitation Amplifier specifications Voltage output: Option 2a Voltage output: Option 2c Voltage output: Option 2t Current three-wire: Option 2j Current two-wire: Option 2k Intrinsically safe amp: Option 2n (2N)*** E F (-) output (+) output Output signal 0 V to 5 V 0 V to 5 V or ±5 45 ma 0 V to 10 V or ±10 45 ma 4 ma to 20 ma 4 ma to 20 ma 4 ma to 20 ma Deflections and ringing frequencies Capacity (lb) full scale (in) Natural ringing frequency (Hz) Weight kg [lb] 5 to [0.8] 50 to [1.5] 2000 to [1.6] 7500 to [6.4] to [6.6] to [11.7] [23.8] [26.5] [90.4] Input power (voltage) Input power (current) Freq. resp (amp) Power supply rej. Operating temp. Reverse voltage protection Short cir. protection Wiring code: connector (std) 4 ±15 V or 26 Vdc to 32 Vdc 11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 15 Vdc to 40 Vdc 9 Vdc to 28 Vdc 45 ma 40 ma 40 ma 65 ma 4 ma to 28 ma 4 ma to 24 ma 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz 60 db 60 db 60 db 60 db 60 db 60 db -20 F to 185 F -20 F to 185 F -20 F to 185 F 0 F to 185 F 0 F to 185 F -20 F to 185 F Yes Yes Yes Yes Yes Yes Momentary Momentary Momentary Yes Yes Yes B Output common C Supply return E Shunt cal 1 F Shunt cal 2 B Output common** C Supply return ** E Shunt cal 1 F Shunt cal 2 B Output common** C Supply return** E Shunt cal 1 F Shunt cal 2 B Output common** C Supply return** E Shunt cal 1 F Shunt cal 2 B No connection C No connection E Case ground F No connection B No connection C No connection E Case ground F No connection Wiring code: cable 4,5,6 Bl Output common G Supply return W (+) Output B Shunt cal 1 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Bl (+) Output W Case ground Bl (+) Output W Case ground Br Shunt cal 2 Br Shunt cal 2 Br Shunt cal 2 Br Shunt cal 2 Mounting dimensions and characteristics * Black and green wires are internally connected. ** Pins B and C are internally connected. *** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. # s lb D1 mm D2 mm H mm F typ. dia. ØG mm B.C. A mm A* mm B mm B* mm C mm 5, 10, 25 63,5 [2.50] 9,4 [0.37] 24,89 [0.98] #8 50,8 [2.000] 20,83 [0.82] 63,5 [2.5] 19,05 [0.75] 22,86 [0.9] 31,75 [1.25] 50, 100, 250, 500, , 3000, 4000, , 10000, 15000, 20000, , 75000, ,2 [3.00] 1 14,22 [0.56] 29,97 [1.18] 1/4 57,15 [2.250] 20,83 [0.82] 63,5 [2.5] 19,05 [0.75] 22,86 [0.9] 31,75 [1.25] 88,9 [3.50] 17,53 [0.69] 29,97 [1.18] 5/16 66,68 [2.625] 20,83 [0.82] 63,5 [2.5] 19,05 [0.75] 22,86 [0.9] 31,75 [1.25] 114,3 [4.50] 38,1 [1.50] 50,8 [2.00] 3/8 96,27 [3.790] 31,75 [1.25] 58,42 [2.3] 38,1 [1.50] 38,1 [1.5] 50,8 [2.00] 114,3 [4.50] 38,1 [1.50] 50,8 [2.00] 3/8 96,27 [3.790] 31,75 [1.25] 58,42 [2.3] 38,1 [1.50] 38,1 [1.5] 50,8 [2.00] , ,7 [5.50] 50,8 [2.00] 55,37 [2.18] 3/8 122,22 [4.812] 31,75 [1.25] 58,42 [2.3] 38,1 [1.50] 38,1 [1.5] 50,8 [2.00] ,8 [7.00] 63,5 [2.50] 68,1 [2.68] 3/8 152,4 [6.00] 31,75 [1.25] 58,42 [2.3] 38,1 [1.50] 38,1 [1.5] 50,8 [2.00] ,5 [7.50] 63,5 [2.50] 68,1 [2.68] 3/8 171,45 [6.750] 31,75 [1.25] 58,42 [2.3] 38,1 [1.50] 38,1 [1.5] 50,8 [2.00] ,4 [11.0] 120,65 [4.75] 114,3 [4.50] 3/4 241,3 [9.500] 31,75 [1.25] 58,42 [2.3] 38,1 [1.50] 38,1 [1.5] 50,8 [2.00] * Length of load cell with amplified option (see option codes) 184 Questions? Contact us at either , Specifications subject to change.

43 Option codes Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see honeywell.com/tmsensor-ship for updated listings. Load ranges 5, 10, 25, 50, 100, 250, 500, 1000, 2000, 3000, 4000, 5000, 7500, 10000, 15000, 20000, 30000, 50000, 75000, , , , , , lb Temperature compensation Internal amplifiers Internal amplifier enhancements termination 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 1d. -20 F to 130 F 1e. -20 F to 200 F 1f. 70 F to 250 F 2a. Four wire, 0 Vdc to 5 Vdc output 2c. 0 Vdc to 5 Vdc 2j. 4 ma to 20 ma (three-wire) output 2k. 4 ma to 20 ma (two-wire) 10 3a. Input/output isolation 7 3d. Remote buffered shunt calibration 8 6a. Bendix PTIH-10-6P (or equivalent), 6-pin (max. 250 F) 6b. MS connector MS3102E-14S-6P (mates with MS3106E-14S-6S) (max. 160 F) (ranges above 5000 lb) 12 6e. Integral cable: Teflon 1g. 70 F to 325 F 11 1h. 70 F to 400 F 11 1i. -65 F to 250 F 1j. 0 C to 50 C 1k. -20 C to 85 C 1m. -25 C to 110 C 2n (2N) 4 ma to 20 ma (two-wire) intrinsically safe 10 2t. 0 Vdc to 10 Vdc output 2u. Unamplified, mv/v output 6f. Integral cable: PVC 6g. Integral cable: Neoprene 6h. Integral cable: Silicone 6i. Integral underwater cable 6j. 1/2-14 conduit fitting with 5 ft of 4 conductor PVC cable Allowable maximum loads 2 Capacity (lb) Side load (lb) Bending (lb-in) Torque (lb-ft) 5 to % 40 % 25 % 50 to % 35 % 25 % 2000 to % 25 % 25 % 7500 to % 20 % 15 % to % 20 % 15 % to % 20 % 15 % % 20 % 10 % % 20 % 10 % % 20 % 10 % Shunt calibration 8a. Precision internal resistor 11 Special calibration 9a. 10 point (5 up/5 down) 20 % 70 F 9b. 20 point (10 up/10 down) 10 % 70 F 9c. ASTM E-74 calibration Bridge resistance Bridge type Zero and span adjustment connector orientation Special calibration Shock and vibration ohm (foil) (max. 250 F) 31a. Dual bridge 14a. No access to pots 14b. Top access to pots 15a. Horizontal electrical exit port orientation 15b. Vertical electrical exit port orientation 15c. Radial electrical exit port orientation 15d. Connector on end of cable 30a. Compression only, positive output 44a. Shock and vibration resistance Typical system diagram Interfaces 53e. Signature calibration 11 53t. TEDS IEEE module 8 Special requirements (consult factory) Have a special requirement? New diameter cable, different cable lengths, radiation proof, psi, output options, temperature settings, TEDS IEEE modules, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. Specifications subject to change. Questions? Contact us at either , 185

44 Model 73 Precision Fatigue Rated Low Profile Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: BL113 CV 6h Order codes BL113 Order code code Option code Model 73 precision fatigue rated low profile load cell 50 lb to lb mv/v output Stainless steel Double diaphragm design 0.10 % accuracy Enhanced overload capacity Intrinsically safe available (2N option only) 7 CE approved 8 BN BR CN CR CV DL DN DP DR DT 50 lb 100 lb 250 lb 500 lb 1000 lb 2000 lb 3000 lb 4000 lb 5000 lb 7500 lb DV EJ EL EN EP ER ET FJ FL lb lb lb lb lb lb lb lb lb Notes 1. Allowable maximum loads - maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 3. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal provides 50 % (unamplified units), 75 % (4 ma to 20 ma threewire units) or 80 % (voltage amplified units) of full scale output for quick calibration. Shunt calibration comes standard with internal amplifier option 2a, 2b, 2c, 2t and 2j. 4. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown; W=White; G=Green. Color specifying cable and number or letter specifying connector. 5. No mating connector necessary for cable option. 6. Consult factory for TEDS availability with amplified models. 7. dependent; consult factory. Termination dependent; consult factory. 8. Internal amp and termination dependent; consult factory. 9. This unit calibrated to Imperial (non-metric) units. 10. Input/output isolation only available with voltage output (2b or 2c) amplifier ohm bridge required. 12. Cannot be used with amplified option. 13. Cannot be used with options 1c, 1e, 1f, 1g, 1g, or 1i. Specifications Performance Load ranges 9 50 lb to lb Non-linearity ±0.1 % full scale Hysteresis ±0.1 % full scale Non-repeatability ±0.03 % full scale Output (tolerance) 2 mv/v ±0.5 % full scale Operation Compression Resolution Infinite Standard calibration 5-point calibration, 0 %, 50 %, and 100 % F.S. in compression only Environmental Temperature, operating -54 C to 121 C [-65 F to 250 F] Temperature, compensated 15 C to 71 C [60 F to 160 F] Temperature effect, zero % full scale/ F Temperature effect, span % full scale/ F Strain gage type Bonded foil Excitation (calibration) 10 Vdc Insulation resistance Vdc Bridge resistance (tolerance) 350 ohm Zero balance (tolerance) ±1 % full scale Shunt calibration data Included termination (std) 50 lb to 2000 lb PTIH-10-6P 3000 lb to lb MS3102E-14S-6P Mating connector (not included) 50 lb to 2000 lb PT06A-10-6S or equiv. (AA111) 3000 to lb MS3106A-14S-6S (AA121) Mechanical Maximum allowable load 200 % FS 1 Weight Material 17-4PH stainless steel Life cycles (approx.) > 10 8 cycles fully reversed Deflection Natural frequency Approved Approved Approved Intrinsically safe amp 186 Questions? Contact us at either , Specifications subject to change.

45 Wiring codes Internal amplifiers Connector A B C D Unamplified (Std.) (+) excitation (+) excitation (-) excitation (-) excitation Amplifier specifications Voltage output: Option 2a Voltage output: Option 2c Voltage output: Option 2t Current three-wire: Option 2j Current two-wire: Option 2k Intrinsically safe amp: Option 2n (2N)*** E F (-) output (+) output Output signal 0 V to 5 V 0 V to 5 V or ±5 45 ma 0 V to 10 V or ±10 45 ma 4 ma to 20 ma 4 ma to 20 ma 4 ma to 20 ma Deflections and ringing frequencies Capacity (lb) full scale (in) Natural ringing frequency (Hz) Weight g [lb] 50 to [1.6] 1000 to ,54 [2.1] 3000 to ,35 [6.5] to ,70 [6.6] to ,10 [12.0] to ,19 [26.5] Input power (voltage) Input power (current) Freq. resp (amp) Power supply rej. Operating temp. Reverse voltage protection Short cir. protection ±15 V or 26 Vdc to 32 Vdc 11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 15 Vdc to 40 Vdc 9 Vdc to 28 Vdc 45 ma 40 ma 40 ma 65 ma 4 ma to 28 ma 4 ma to 24 ma 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz 60 db 60 db 60 db 60 db 60 db 60 db -20 F to 185 F -20 F to 185 F -20 F to 185 F 0 F to 185 F 0 F to 185 F -20 F to 185 F Yes Yes Yes Yes Yes Yes Momentary Momentary Momentary Yes Yes Yes Wiring code: connector (std) 4 B Output common C Supply return E Shunt cal 1 F Shunt cal 2 B Output common** C Supply return ** E Shunt cal 1 F Shunt cal 2 B Output common** C Supply return** E Shunt cal 1 F Shunt cal 2 B Output common** C Supply return** E Shunt cal 1 F Shunt cal 2 B No connection C No connection E Case ground F No connection B No connection C No connection E Case ground F No connection Wiring code: cable 4,5,6 Bl Output common G Supply return W (+) Output B Shunt cal 1 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Bl (+) Output W Case ground Bl (+) Output W Case ground Br Shunt cal 2 Br Shunt cal 2 Br Shunt cal 2 Br Shunt cal 2 Mounting dimensions and characteristics * Black and green wires are internally connected. ** Pins B and C are internally connected. *** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. # s lb D1 mm D2 mm H mm ØF type. dia. G mm B.C. A mm A* mm B mm B* mm C mm 50 to ,2 [3.00] 14,22 [0.56] 29,97 [1.18] 1/4 57,15 [2.250] 20,83 [0.82] 63,5 [2.5] 19,05 [0.75] 22,86 [0.9] 31,75 [1.25] 1000 to ,9 [3.50] 17,53 [0.69] 29,97 [1.18] 5/16 66,68 [2.625] 20,83 [0.82] 63,5 [2.5] 19,05 [0.75] 22,86 [0.9] 31,75 [1.25] 3000 to ,3 [4.50] 38,1 [1.50] 50,8 [2.00] 3/8 46,27 [3.790] 31,75 [1.25] 58,42 [2.3] 38,1 [1.50] 38,1 [1.5] 50,8 [2.00] to ,3 [4.50] 38,1 [1.50] 50,8 [2.00] 3/8 46,27 [3.790] 31,75 [1.25] 58,42 [2.3] 38,1 [1.50] 38,1 [1.5] 50,8 [2.00] to ,7 [5.50] 50,8 [2.00] 55,37 [2.18] 3/8 122,22 [4.812] 31,75 [1.25] 58,42 [2.3] 38,1 [1.50] 38,1 [1.5] 50,8 [2.00] to ,5 [7.50] 63,5 [2.50] 68,1 [2.68] 3/8 171,45 [6.750] 31,75 [1.25] 58,42 [2.3] 38,1 [1.50] 38,1 [1.5] 50,8 [2.00] * Length of load cell with amplified option (see option codes) Specifications subject to change. Questions? Contact us at either , 187

46 Option codes Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see honeywell.com/tmsensor-ship for updated listings. Load ranges 50, 100, 250, 500, 1000, 2000, 3000, 4000, 5000, 7500, 10000, 15000, 20000, 30000, 50000, 75000, , , lb Temperature compensation Internal amplifiers Internal amplifier enhancements termination 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 1d. -20 F to 130 F 1e. -20 F to 200 F 1f. 70 F to 250 F 2b. Four-wire, 0 Vdc to 5 Vdc output 2c. 0 Vdc to 5 Vdc 2j. 4 ma to 20 ma (three-wire) output 2k. 4 ma to 20 ma (two-wire) 11 3a. Input/output isolation 10 3d. Remote buffered shunt calibration 8 6a. Bendix PTIH-10-6P (or equivalent), 6-pin (max. 250 F) 6b. MS connector MS3102E-14S-6P (mates with MS3106E-14S-6S) (max. 160 F) (ranges 2000 and above) 13 6e. Integral cable: Teflon Shunt calibration 8a. Precision internal resistor 12 Bridge resistance Bridge type Zero and span adjustment connector orientation Special calibration Shock and vibration 12b ohm (foil) (max. 250 F) 31a. Dual bridge 14a. No access to pots 14b. Top access to pots 15a. Horizontal electrical exit port orientation 15b. Vertical electrical exit port orientation 15c. Radial electrical exit port orientation 15d. Connector on end of cable 1g. 70 F to 325 F 12 1h. 70 F to 400 F 12 1i. -65 F to 250 F 12 1j. 0 F to 50 C 1k. -20 C to 85 C 1m. -25 C to 110 C 30a. Compression only, positive output 9a. 10 point (5 up/5 down) 20 % 70 F 9b. 20 point (10 up/10 down) 10 % 70 F 9c. ASTM E-74 calibration 44a. Shock and vibration resistance 2n (2N) 4 ma to 20 ma (two-wire) intrinsically safe 11 2t. 0 Vdc to 10 Vdc output 2u. Unamplified, mv/v output 6f. Integral cable: PVC 6g. Integral cable: Neoprene 6h. Integral cable: Silicone 6i. Integral underwater cable 6j. 1/2-14 conduit fitting with 5 ft of 4 conductor PVC cable Allowable maximum loads 2 Capacity (lb) Side load (% FS) Bending (lb-in) Torque (lb-ft) 50 to % 60 % 35 % 1000 to % 35 % 35 % 3000 to % 30 % 35 % to % 30 % 25 % to % 30 % 15 % to % 30 % 15 % Typical system diagram Interfaces 53e. Signature calibration 12 53t. TEDS IEEE module 6 Special requirements (consult factory) Have a special requirement? New diameter cable, different cable lengths, radiation proof, psi, output options, temperature settings, TEDS IEEE modules, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. 188 Questions? Contact us at either , Specifications subject to change.

47 Model 31 Low Precision Miniature Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: AL311 AJ 1b, 30a Order codes AL311 Order code code Option code Low range precision miniature load cell 50 g to 500 g mv/v output Stainless steel Miniature design Double diaphragm construction AJ AL AN AP 50 g 150 g 250 g 500 g Notes 1. Allowable maximum loads - maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life or long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 3. Standard calibration for tension/compression load cells is in tension only. 4. TEDS available with integral cable units only. 5. This unit calibrated to Imperial (non-metric) units. 6. Signature calibration only available as inline module. Specifications Performance Load ranges 5 50 g, 150 g, 250 g, 500 g Linearity ±0.15 % full scale Hysteresis ±0.15 % full scale Non-repeatability ±0.1 % full scale Tolerance on output 50 g to 150 g 0,1 mv/v max. 250 g to 500 g 20 mv/v Operation Tension/compression 3 Resolution Infinite Environmental Temperature, operating -53 C to 121 C [-65 F to 250 F] Temperature, compensated 15 C to 71 C [60 F to 160 F] Storage temperature -73 C to 148 C [-100 F to 300 F] Temperature effect, zero % full scale/ F Temperature effect, span % full scale/ F Strain gage type Excitation (calibration) Insulation resistance Bridge resistance Zero balance termination (std) Semiconductor 5 Vdc Vdc 500 ohm 1 % max. Teflon cable (5 ft) Mechanical Maximum allowable load 5 lb 1 Weight 90 g Material 17-4 PH stainless steel Deflection full scale 0,020 mm [ in] Natural frequency 740 Hz Specifications subject to change. Questions? Contact us at either , 189

48 Option codes Wiring codes Load range Temperature compensation Internal amplifiers Overload stops termination Special calibration Shock and vibration Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see com/tmsensor-ship for updated listings. 50, 150, 250, 500 g 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 1d. -20 F to 130 F 2u. Unamplified, mv/v output 4a. Overload stop 6d. Microtec DR-4S-4H 4-pin 6e. Integral cable: Teflon 6f. Integral cable: PVC 6h. Integral cable: Silicone 1e. -20 F to 200 F 1j. 0 F to 50 C 1k. -20 C to 85 C 1m. -25 C to 110 C 6i. Integral underwater cable (max. 82 C [180 F]) 6v. Phoenix connector on end of cable 15d. Connector on end of cable 30a. Compression only calibration, positive in compression 30b. Tension and compression calibration, positive in tension 30c. Compression only calibration, negative in compression 44a. Shock and vibration resistance Cable Unamplified Red (+) excitation Black (-) excitation Green (-) output White (+) output Typical system diagram Interfaces 4 53e. Signature calibration 6 53t. TEDS IEEE module Mounting dimensions and characteristics 6-32 UNC base thread Special requirements (consult factory) Have a special requirement? New case pressure, different cable lengths, electrical connectors, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. 190 Questions? Contact us at either , Specifications subject to change.

49 Model 31 Mid- Precision Miniature Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: AL311 CV 1b, 30a Order codes AL311 Order code code Option code Model 31 mid-range precision miniature load cell 1000 g to 1000 lb mv/v output Stainless steel Miniature design AR AT AV BL BN BR CN CR CV 1000 g 5 lb 10 lb 25 lb 50 lb 100 lb 250 lb 500 lb 1000 lb Notes 1. Allowable maximum loads - maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 3. Standard calibration for tension/compression load cells is in tension only. 4. TEDS available with integral cable units only. 5. Availability varies with range. 6. This unit calibrated to Imperial (non-metric) units. 7. Signature calibration only available as inline module. Specifications Performance Load ranges g, 5 lb, 10 lb, 25 lb, 50 lb, 100 lb, 250 lb, 500 lb, 1000 lb Linearity 1000 g to 250 lb ±0.15 % full scale 500 lb to 1000 lb ±0.2 % full scale Hysteresis 1000 g to 250 lb ±0.15 % full scale 500 lb to 1000 lb ±0.2 % full scale Non-repeatability 1000 g ±0.1 % full scale 5 lb to 1000 lb ±0.05 % full scale Tolerance on output 1000 g 1.5 mv/v (nominal) 5 lb to 1000 lb 2 mv/v Operation Tension/compression 3 Resolution Infinite Environmental Temperature, operating -53 C to 121 C [-65 F to 250 F] Temperature, compensated 15 C to 71 C [60 F to 160 F] Storage temperature -73 C to 148 C [-100 F to 300 F] Temperature effect, zero % full scale/ F Temperature effect, span % full scale/ F Strain gage type Bonded foil Excitation (calibration) 1 kg to 10 lb 5 Vdc 25 lb to 1000 lb 10 Vdc Insulation resistance Vdc Bridge resistance 350 ohm Zero balance 1 % max. termination (std) Teflon cable (1524 mm [60 in]) Mechanical Maximum allowable load 150 % FS 1 Weight Material 17-4 PH stainless steel Deflection full scale Natural frequency Specifications subject to change. Questions? Contact us at either , 191

50 Option codes Load range Temperature compensation Internal amplifiers Overload stops termination Special calibration Special calibration Shock and vibration Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see for updated listings g, 5 lb, 10 lb, 25 lb, 50 lb, 100 lb, 250 lb, 500 lb, 1000 lb 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 1d. -20 F to 130 F 1e. -20 F to 200 F 1f. 70 F to 250 F 2u. Unamplified, mv/v output 4a. Overload stops 6a. Bendix PTIH-10-6P - 6 pin (max. 250 F) 5 6d. Microtec DR-4S-4H 4 pin 6e. Integral cable: Teflon 6f. Integral cable: PVC 1g. 70 F to 325 F 1h. 70 F to 400 F 1i. -65 F to 250 F 1j. 0 C to 50 C 1k. -20 C to 85 C 1m. -25 to 110 C 9a. 10 point (5 up/5 down) 20 % 20 C 9b. 20 point (10 up/10 down) 10 % 20 C 6h. Integral cable: Silicone 6i. Integral underwater cable (max. 180 F) 6v. Phoenix connector on end of cable 15d. Connector on end of cable 30a. Compression only calibration, positive in compression 30b. Tension and compression calibration, positive in tension 30c. Compression only calibration, negative in compression 44a. Shock and vibration resistance Interfaces 4 53e. Signature calibration 7 53t. TEDS IEEE module Wiring codes Cable Red Black Green White Deflections and ringing frequencies Capacity (lb) Deflection at full scale (in) Ringing frequency (Hz) Weight (g) 1000 g to 10 lb 0,03 mm [0.001 in] 3000 Hz 21 g 25 lb to 100 lb 0,03 mm [0.001 in] Hz 63 g 250 lb to 1000 lb 0,04 mm [ in] Hz 80 g Mounting dimensions and characteristics s (lb) T H C F A B 1000 g, 5 lb, 10 lb 25 lb, 50 lb, 100 lb 250 lb, 500 lb, 1000 lb Unamplified (+) excitation (-) excitation (-) output (+) output #6-32 UNC 11,43 mm [0.45 in] #10-32 UNF 13,21 mm [0.52 in] 1/4-28 UNF 13,21 mm [0.52 in] 6,35 mm [0.25 in] 6,35 mm [0.25 in] 9,65 mm [0.38 in] 1,27 mm [0.05 in] 0,76 mm [0.03 in] 0,76 mm [0.03 in] 7,87 mm [0.31 in] 12,7 mm [0.50 in] 12,7 mm [0.50 in] 4,83 mm [0.19 in] 6,35 mm [0.25 in] 6,35 mm [0.25 in] Typical system diagram Special requirements (consult factory) Have a special requirement? New case pressure, different cable lengths, electrical connectors, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. 192 Questions? Contact us at either , Specifications subject to change.

51 Model 31 High Precision Miniature Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: AL311 DV 1b, 30a Order codes AL311 Order code code Option code High range precision miniature load cell 2000 lb to lb mv/v output Stainless steel Miniature design Stabilized column construction DL DN DP DR DT DV 2000 lb 3000 lb 4000 lb 5000 lb 7500 lb lb Notes 1. Allowable maximum loads - maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 3. Standard calibration for tension/compression load cells is in tension only. 4. TEDS available with integral cable units only. 5. This unit calibrated to Imperial (non-metric) units. 6. Signature calibration only available as inline module. Specifications Performance Load ranges lb to lb Linearity ±0.2 % full scale Hysteresis ±0.2 % full scale Non-repeatability ±0.05 % full scale Tolerance on output 2 mv/v Operation Tension/compression 3 Resolution Infinite Environmental Temperature, operating Temperature, compensated Storage temperature Temperature effect, zero Temperature effect, span -53 C to 121 C [-65 F to 250 F] 15 C to 71 C [60 F to 160 F] -73 C to 148 C [-100 F to 300 F] % full scale/ F % full scale/ F Strain gage type Excitation (calibration) Insulation resistance Bridge resistance Zero balance termination (std) Bonded foil 5 Vdc Vdc 350 ohm 1 % max. Teflon cable (1524 mm [60 in]) Mechanical Maximum allowable load 150 % FS 1 Weight Material 17-4 PH stainless steel full scale Natural frequency Specifications subject to change. Questions? Contact us at either , 193

52 Option codes Wiring codes Load range Temperature Compensation Internal amplifiers termination Bridge resistance connector orientation Special calibration Shock and vibration Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see com/tmsensor-ship for updated listings lb, 3000 lb, 4000 lb, 5000 lb, 7500 lb, lb 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 1d. -20 F to 130 F 1e. -20 F to 200 F 1f. 70 F to 250 F 2u. Unamplified, mv/v output 6e. Integral cable: Teflon 6d. Microtec DR-4S-4H 4 pin 6f. Integral cable: PVC 6g. Integral cable: Neoprene (max. 180 F) 12a ohm (foil) 12b ohm (foil) 15a. Horizontal electrical exit port orientation 15b. Vertical electrical exit port orientation 15c. Radial electrical exit port orientation 15d. Connector on end of cable 1g. 70 F to 325 F 1h. 70 F to 400 F 1i. -65 F to 250 F 1j. 0 C to 50 C 1k. -20 C to 85 C 1m. -25 C to 110 C 30a. Compression only calibration, positive in compression 30b. Tension and compression calibration, positive in tension 30c. Compression only calibration, negative in compression 30d. Tension and compression calibration, positive in compression 44a. Shock and vibration resistance 6h. Integral cable: Silicone 6i. Integral underwater cable (max. 180 F) 6v. Phoenix connector on end of cable Cable Red Black Green White Deflections and ringing frequencies Capacity Unamplified (+) excitation (-) excitation (-) output (+) output Deflection at full scale Ringing frequency 2000 lb, 3000 lb 0.03 mm [0.001 in] Hz 60 g Weight 4000 lb, 5000 lb 0.04 mm [ in] Hz 125 g 7500 lb, lb 0.04 mm [ in] Hz 250 g Typical system diagram Interfaces 53e. Signature calibration 6 53t. TEDS IEEE module 4 Mounting dimensions and characteristics s (lb) T ød C H 2000 lb, 3000 lb 3/8-24 UNF 25,4 mm [1.00 in] 12,7 mm [0.50 in] 18,29 mm [0.72 in] 4000 lb, 5000 lb 1/2-20 UNF 31,75 mm [1.25 in] 16 mm [0.63 in] 23,88 mm [0.94 in] 7500 lb, lb 3/4-16 UNF 35,05 mm [1.38 in] 22,35 mm [0.88 in] 27,94 mm [1.10 in] Special requirements (consult factory) Have a special requirement? New case pressure, different cable lengths, electrical connectors, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. 194 Questions? Contact us at either , Specifications subject to change.

53 Model 31E Low Precision Miniature Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: 31E 001N0 1J, 30a Order codes 31E Order code code Option code Model 31E low range precision miniature load cell 0.5 N to 5 N mv/v output Stainless steel Miniature design Double diaphragm construction 000N5 0015N5 002N5 005N0 0.5 N 1.5 N 2.5 N 5 N Notes 1. Allowable maximum loads - maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 3. Standard calibration for tension/compression load cells is in tension only. 4. TEDS available with integral cable units only. 5. This unit is calibrated to Metric (non-imperial) units. Specifications Performance Load ranges N, 1.5 N, 2.5 N, 5 N Linearity ±0.15 % full scale Hysteresis ±0.15 % full scale Non-repeatability ±0.1 % full scale Tolerance on output 0.5 N to 1.5 N 0.1 mv/v/n max. 2.5 N to 5 N 20 mv/v Operation Tension/compression 3 Resolution Infinite Environmental Temperature, operating Temperature, compensated Storage temperature Temperature effect, zero Temperature effect, span -55 C to 120 C [-67 F to 248 F] 15 C to 70 C [59 F to 158 F] -70 C to 150 C [-94 F to 302 F] 0.03 % full scale/ C 0.03 % full scale/ C Strain gage type Excitation (calibration) Insulation resistance Bridge resistance Zero balance termination (std) Semiconductor 5 Vdc Vdc 500 ohm 1 % max. Teflon cable (1.5 m [59.06 in]) Mechanical Maximum allowable load 20 N 1 Weight 90 g Material 17-4 PH stainless steel Deflection full scale 11 kg/mm Natural frequency 740 Hz Specifications subject to change. Questions? Contact us at either , 195

54 Option codes Wiring codes Load range Temperature compensation Internal amplifiers termination Special calibration Shock and vibration Interfaces 4 Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see for updated listings. 0.5 N, 1.5 N, 2.5 N, 5 N 1a. 15 C to 70 C 1j. 0 C to 50 C 2u. Unamplified, mv/v output 6d. Microtec DR-4S-4H 4 pin 6e. Integral cable: Teflon 6f. Integral cable: PVC 6g. Integral cable: Neoprene (max. 80 C [176 F]) 1k. -20 C to 85 C 1m. -25 C to 110 C 30a. Compression only calibration, positive in compression 30b. Tension and compression calibration, positive in tension 30c. Compression only calibration, negative in compression 30d. Tension and compression calibration, positive in compression 44a. Shock and vibration resistance 53e. Signature calibration 53t. TEDS IEEE module 6h. Integral cable: Silicone 6i. Integral underwater cable (max. 80 C [176 F]) 6v. Phoenix connector on end of cable 15d. Connector on end of cable Cable Unamplified Red (+) excitation Black (-) excitation Green (-) output White (+) Output Typical system diagram Mounting dimensions and characteristics Special requirements (consult factory) Have a special requirement? New case pressure, different cable lengths, electrical connectors, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. 196 Questions? Contact us at either , Specifications subject to change.

55 Model 31E Mid- Precision Miniature Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: 31E 020N0 1j, 30a Order codes 31E Order code code Option code Model 31E mid-range precision miniature load cell 10 N to 5 kn mv/v output Stainless steel Miniature design 010N0 020N0 050N0 100N0 200N0 500N0 01KN0 02KN0 05KN0 10 N 20 N 50 N 100 N 200 N 500 N 1 kn 2 kn 5 kn Notes 1. Allowable maximum loads maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 3. Standard calibration for tension/compression load cells is in tension only. 4. TEDS available with integral cable units only. 5. Availability varies with range. 6. This unit is calibrated to Metric (non-imperial) units. 7. Signature calibration only available as inline module. Specifications Performance Load ranges 6 10 N to 5 kn Linearity 10 N to 1 kn ±0.15 % full scale 2 kn to 5 kn ±0.2 % full scale Hysteresis 10 N to 1 kn ±0.15 % full scale 2 kn to 5 kn ±0.2 % full scale Non-repeatability 10 N ±0.1 % full scale 2 N to 5 kn ±0.05 % full scale Tolerance on output 10 N 1.5 mv/v (nominal) 20 N to 5 kn 2 mv/v Operation Tension/compression 3 Resolution Infinite Environmental Temperature, operating -55 C to 120 C [-67 F to 248 F] Temperature, compensated 15 C to 70 C [60 F to 158 F] Temperature, storage -70 C to 150 C [-100 F to 302 F] Temperature effect, zero 0.01 % full scale/ C Temperature effect, span 0.01 % full scale/ C Strain gage type Bonded foil Excitation (calibration) 10 N to 20 N 5 Vdc 50 N to 5 kn 10 Vdc Insulation resistance Vdc Bridge resistance 350 Ohm Zero balance 1 % max. termination (std) Teflon cable (1.5 m [60 in]) Mechanical Maximum allowable load 150 % FS 1 Weight Material 17-4 PH stainless steel Deflection full scale Natural frequency Specifications subject to change. Questions? Contact us at either , 197

56 Options code Load range Temperature compensation Internal amplifiers termination Special calibration Special calibration Shock and vibration Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see for updated listings. 10, 20, 50, 100, 200, 500 N; 1, 2, 5kN 1a. 60 F to 160 F 1b. -30 F to 130 F 1c. 0 F to 185 F 1d. -20 F to 200 F 1e. -20 F to 200 F 1f. 70 F to 250 F 2u. Unamplified, mv/v output 6a. Bendix PTIH-10-6P - 6-pin (max. 120 C) 5 6d. Microtec DR-4S-4H 4-pin 6e. Integral cable: Teflon 6f. Integral cable: PVC 1g. 70 F to 325 F 1h. 70 F to 400 F 1i. -65 F to 250 F 1j. 0 C to 50 C 1k. -20 C to 85 C 1m. -25 to 110 C 6g. Integral cable: Neoprene (max. 80 C) 6h. Integral cable: Silicone 6i. Integral underwater cable (max. 80 C) 6v. Phoenix connector on end of cable 9a. 10 point (5 up/5 down) 20 % 20 C [68 F] 9b. 20 point (10 up/10 down) 1 % 20 C [68 F] 30a. Compression only calibration, positive in compression 30b. Tension and compression calibration, positive in tension 30c. Compression only calibration, negative in compression 44a. Shock and vibration resistance Interfaces 53e. Signature calibration 7 53t. TEDS IEEE module 4 Typical system diagram Wiring codes Cable Red Black Green White Deflections and ringing frequencies Capacity Deflection at full scale (in) Ringing frequency (Hz) Weight (g) 10 N to 50 N 0,02 mm [ in] 3000 Hz 21 g 100 N to 500 N 0,02 mm [ in] Hz 63 g 1 kn to 5 kn 0,03 mm [0.001 in] Hz 80 g Mounting dimensions and characteristics s (lb) T H (in) C (in) F (in) A (in) B (in) 10 N, 20 N, 50 N M4 x ,43 mm [0.45 in] 100 N, 200 N, 500 N M5 x 0.8 Unamplified (+) excitation (-) excitation (-) output (+) output 13,21 mm [0.52 in] 1kN, 2kN, 5kN M6 x 1 13,21 mm [0.52 in] 6,35 mm [0.25 in] 6,35 mm [0.25 in] 9,65 mm 0.38 in 1,27 mm [0.05 in] 0,76 mm [0.03 in] 0,76 mm 0.03 in 7,87 mm [0.31 in] 12,7 mm [0.50 in] 12,7 mm [0.50 in] 4,83 mm [0.19 in] 6,35 mm [0.25 in] 6,35 mm [0.25 in] Special requirements (consult factory) Have a special requirement? New case pressure, different cable lengths, electrical connectors, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. 198 Questions? Contact us at either , Specifications subject to change.

57 Model 31E High- Precision Miniature Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: 31E 10KN0 1j, 30a Order code 31E Order code code Option code Model 31E high-range precision miniature load cell code 10 kn to 50 kn mv/v output Stainless steel Miniature design Stabilization column construction Notes 1. Allowable maximum loads maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 3. Standard calibration for tension/compression load cells is in tension only. 4. TEDS available with integral cable units only. 5. This unit is calibrated to Metric (non-imperial) units. 6. Signature calibration only available as inline module. 10KN0 20KN0 50KN0 10 kn 20 kn 50 kn Specifications Performance Load ranges 5 10 kn, 20 kn, 50 kn Linearity ±0.2 % full scale Hysteresis ±0.2 % full scale Non-repeatability ±0.05 % full scale Tolerance on output 2 mv/v Operation Tension/compression 3 Resolution Infinite Environmental Temperature, operating Temperature, compensated Storage temperature Temperature effect, zero Temperature effect, span Strain gage type Excitation (calibration) Insulation resistance Bridge resistance Zero balance termination (std) -55 C to 120 C [-67 F to 248 F] 15 C to 70 C [60 F to 158 F] -70 C to 150 C [-100 F to 302 F] 0.01 % full scale/ C 0.01 % full scale/ C Bonded foil 5 Vdc Vdc 350 ohm 1 % max. Teflon cable (1.5 m [60 in]) Mechanical Maximum allowable load 150 % FS 1 Weight Material 17-4 PH stainless steel Deflection full scale Natural frequency Specifications subject to change. Questions? Contact us at either , 199

58 Option codes Wiring codes Load range Temperature compensation Internal amplifiers termination Bridge resistance connector orientation Special calibration Shock and vibration Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see com/tmsensor-ship for updated listings. 10kN, 20kN, 50 kn 1a. 15 C to 70 C 1j. 0 C to 50 C 1k. -20 C to 85 C 1m. -25 to 110 C 2u. Unamplified, mv/v output 6e. Integral cable: Teflon 6d. Microtec DR-4S-4H 4-pin 6f. Integral cable: PVC 6g. Integral cable: Neoprene (max. 80 C) 6h. Integral cable: Silicone 6i. Integral underwater cable (max. 80 C) 6v. Phoenix connector on end of cable 12a ohm (foil) 12b ohm foil 15a. Horizontal electrical exit port orientation 15b. Vertical electrical exit port orientation 15c. Radial electrical exit port orientation 15d. Connector on end of cable 30a. Compression only calibration, positive in compression 30b. Tension and compression calibration, positive in tension 30c. Compression only calibration, negative in compression 30d. Tension and compression calibration, positive in compression 44a. Shock and vibration resistance Cable Unamplified Red (+) excitation Black (-) excitation Green (-) output White (+) output Deflections and ringing frequencies Capacity (kn) Deflection at full scale Ringing frequency (Hz) Weight 10 kn 0,02 mm [ in] Hz 60 g [0.132] 20 kn 0,03 mm [ in] Hz 125 g [0.276] 50 kn 0,03 mm [ in] Hz 250 g [0.551] Typical system diagram Interfaces 53e. Signature calibration 6 53t. TEDS IEEE module 4 Mounting dimensions and characteristics s (kn) T ØD mm H mm C mm 10 M10 x ,4 [1.0] 18,3 [0.72] 12,7 [0.5] 20 M12 x ,8 [1.25] 23,9 [0.94] 16,0 [0.63] 50 M20 x ,1 [1.38] 27,9 [1.1] 22,3 [0.88] Special requirements (consult factory) Have a special requirement? New case pressure, different cable lengths, electrical connectors, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. 200 Questions? Contact us at either , Specifications subject to change.

59 Model 34 Semi- Precision Miniature Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: AL312 AJ 1b, 30a Order codes AL312 Order code code Option code Model 34 semi-precision miniature load cell 50 g to 500 g mv/v output Stainless steel Miniature design Double diaphragm construction Notes 1. Allowable maximum loads maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 3. Standard calibration for tension/compression load cells is in tension only. 4. TEDS available with integral cable units only. 5. This unit calibrated to Imperial (non-metric) units. 6. Signature calibration module only available as inline module. AJ AL AN AP 50 g 150 g 250 g 500 g Specifications Performance Load ranges 5 50 g, 150 g, 250 g, 500 g Linearity ±0.15 % full scale Hysteresis ±0.15 % full scale Non-repeatability ±0.1 % full scale Tolerance on output 50 g to 150 g 0.1 mv/v/g max. 250 g to 500 g 20 mv/v Operation Tension/compression 3 Resolution Infinite Environmental Temperature, operating Temperature, compensated Storage temperature Temperature effect, zero Temperature effect, span -54 C to 121 C [-65 F to 250 F] 15 C to 71 C [60 F to 160 F] -70 C to 149 C [-100 F to 300 F] % full scale/ F % full scale/ F Strain gage type Excitation (calibration) Insulation resistance Bridge resistance Zero balance termination (std) Semiconductor 4 Vdc Vdc 350 ohm 1 % max. Teflon cable (1.83 m [5 ft]) Mechanical Maximum allowable load 5 lb 1 Weight 110 g Material 17-4 PH stainless steel full scale 0,020 mm [ in] Natural frequency Specifications subject to change. Questions? Contact us at either , 201

60 Option codes Wiring codes Load range Temperature compensation Internal amplifiers Overload stop termination Special calibration Shock and vibration Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see com/tmsensor-ship for updated listings. 50, 150, 250, 500 g 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 1d. -20 F to 130 F 2u. Unamplified, mv/v output 4a. Overload stop 6d. Microtec DR-4S-4H 4-pin 6e. Integral cable: Teflon 6f. Integral cable: PVC 6v. Phoenix connector on end of cable 1e. -20 F to 200 F 1j. 0 C to 50 C 1k. -20 C to 85 C 1m. -25 to 110 C 30a. Compression only calibration, positive in compression 30b. Tension and compression calibration, positive in tension 30c. Compression only calibration, negative in compression 44a. Shock and vibration resistance 6g. Integral cable: Neoprene (max. 180 F) 6h. Integral cable: Silicone 6i. Integral underwater cable (max. 180 F) 15d. Connector on end of cable Cable Unamplified Red (+) excitation Black (-) excitation Green (-) output White (+) output Deflections and ringing frequencies Capacity (lb) Ringing frequency (Hz) Weight (g) 1000 g to 10 lb 3000 Hz 21 g 25 lb to 100 lb Hz 63 g 250 lb to 1000 lb Hz 80 g Typical system diagram Interfaces 53e. Signature calibration 6 53t. TEDS IEEE module 4 Mounting dimensions and characteristics Special requirements (consult factory) Have a special requirement? New case pressure, different cable lengths, electrical connectors, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. 202 Questions? Contact us at either , Specifications subject to change.

61 Model 34 Precision Miniature Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: AL312 CV 1b, 30a Order code code Option code Order codes AL312 Model 34 precision miniature load cell 1000 g to 1000 lb range Welded stainless steel Rugged, small size Tension/compression 0.15 %/0.20 % accuracy Notes 1. Allowable maximum loads maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 3. Standard calibration for tension/compression load cells is in tension only. 4. Option 53e and 53t are external in-line interfaces. 5. Availability varies with range. 6. This unit calibrated to Imperial (non-metric) units. 7. Not available with 500 g range. AR AT AV BL BN 1000 g 5 lb 10 b 25 lb 50 lb Specifications Performance Load ranges g to 1000 lb Linearity 1000 g to 250 lb ±0.15 % full scale 500 lb to 1000 lb ±0.2 % full scale Hysteresis 1000 g to 250 lb ±0.15 % full scale 500 lb to 1000 lb ±0.2 % full scale Non-repeatability 1000 g ±0.1 % full scale 5 lb to 1000 lb ±0.05 % full scale Tolerance on output 1000 g 1.5 mv/v (nominal) 5 lb to 1000 lb 2 mv/v Operation Tension/compression 3 Resolution Infinite Environmental Temperature, operating -53 C to 121 C [-65 F to 250 F] Temperature, compensated 15 C to 71 C [60 F to 160 F] Storage temperature -73 C to 148 C [-100 F to 300 F] Temperature effect, zero % full scale/ F Temperature effect, span % full scale/ F BR CN CR CV 100 lb 250 lb 500 lb 1000 lb Strain gage type Bonded foil Excitation (calibration) 1000 g to 10 lb 5 Vdc 25 lb to 1000 lb 10 Vdc Insulation resistance Vdc Bridge resistance 350 ohm termination (std) 1000 g to 10 lb Teflon cable (5 ft) with external balance board 25 lb to 1000 lb Teflon cable (5 ft) Mechanical Maximum allowable load 150 % FS 1 Weight Material 17-4 PH stainless steel Deflection full scale Natural frequency Specifications subject to change. Questions? Contact us at either , 203

62 Option codes Wiring codes Load range Temperature compensation Internal amplifiers Overload stop termination Special calibration Special calibration Shock and vibration Interfaces 4 Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see for updated listings. 500 g, 1000 g; 5, 10, 15, 25, 50, 100, 250, 500, 1000 lb 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 1d. -20 F to 130 F 1e. -20 F to 200 F 1j. 0 C to 50 C 2a. Unamplified, mv/v output 4a. Overload stop 6a. Bendix PTIH-10-6P - 6-pin (max. 250 F) 5 6d. Microtec DR-4S-4H 4-pin 6e. Integral cable: Teflon 6f. Integral cable: PVC 9a. 10 point (5 up/5 down) 20 % 20 C 9b. 20 point (10 up/10 down) 10 % 20 C 30a. Compression only calibration, positive in compression 30b. Tension and compression calibration, positive in tension 30c. Compression only calibration, negative in compression 44a. Shock and vibration resistance 53e. Signature calibration 53t. TEDS IEEE module 1k. -20 C to 85 C 1m. -25 to 110 C 7 1f. 70 F to 250 F 1g. 70 F to 325 F 7 1h. 70 F to 400 F 7 1i. -65 F to 250 F 7 6g. Integral cable: Neoprene (max. 180 F) 6h. Integral cable: Silicone 6i. Integral underwater cable (max. 180 F) 6v. Phoenix connector on end of cable 15d. Connector on end of cable Cable Unamplified Red (+) excitation Black (-) excitation Green (-) output White (+) output Deflections and ringing frequencies Capacity Deflection at full scale Ringing frequency (Hz) Weight 1000 g to 10 lb 0,03 mm [0.001 in] 1000 Hz 40 g [0.09 lb] 25 lb to 100 lb 0,03 mm [0.001 in] 3000 Hz 80 g [0.18 lb] 250 lb to 1000 lb 0,05 mm [ in] 5000 Hz 100 g [0.22 lb] Typical system diagram Mounting dimensions and characteristics s D mm H mm A mm B mm C mm F mm G mm T 1000 g, 5 lb, 10 lb 19,05 [0.75] 44,45 [1.75] 7,87 [0.31] 4,83 [0.19] 4,83 [0.46] 15,24 [0.60] 18,29 [0.72] 1/4-28 UNF 25 lb, 50 lb, 100 lb 25,4 [1.00] 44,45 [1.75] 12,7 [0.50] 6,35 [0.25] 4,83 [0.46] 13,21 [0.52] 18,29 [0.72] 1/4-28 UNF 250 lb, 500 lb, 1000 lb 25,4 [1.00] 50,8 [2.00] 12,7 [0.50] 6,35 [0.25] 4,83 [0.46] 19,05 [0.75] 19,05 [0.75] 1/4-28 UNF Special requirements (consult factory) Have a special requirement? New case pressure, different cable lengths, electrical connectors, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. 204 Questions? Contact us at either , Specifications subject to change.

63 Model 11 Subminiature Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: BL321 AT 1b Order codes BL321 Order code code Option code Model 11 subminiature load cell AL 150 g BL 25 lb AN 250 g BN 50 lb 150 g to 1000 lb mv/v output Subminiature design Single diaphragm construction AP AR AT AV 500 g 1000 g 5 lb 10 b BR CN CR CV 100 lb 250 lb 500 lb 1000 lb Notes 1. Allowable maximum loads maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 3. Standard calibration for tension/compression load cells is tension only. 4. A small, 2 in circuit board is included in the cable, 2 ft from the load cell. Do not remove this board. 5. Only for ranges greater-than-or-equal-to 1000 g. 6. Specifications may vary with this option. 7. This unit calibrated to Imperial (non-metric) units. Specifications Performance Load ranges g to 1000 lb Linearity ±0.5 % full scale Hysteresis ±0.5 % full scale Non-repeatability ±0.1 % full scale Tolerance on output 150 g to 500 g 10 mv/v (nominal) 1000 g to 1000 lb 2 mv/v (nominal) Operation Tension/compression 3 Resolution Infinite Maximum permissible torque 150 g to 100 lb 4 in-lb 250 lb to 1000 lb 20 in-lb Environmental Temperature, operating -54 C to 121 C [-65 F to 250 F] Temperature, compensated 15 C to 71 C [60 F to 160 F] Temperature effect, zero 0.01 % full scale/ F Temperature effect, span 0.02 % reading/ F Strain gage type 150 g to 500 g Semiconductor 1000 g to 1000 lb Bonded foil Excitation (calibration) 5 Vdc Insulation resistance Vdc Bridge resistance (tolerance) 150 g to 500 g 500 ohm (nominal) 1000 g to 1000 lb 350 ohm (nominal) Zero balance (tolerance) ±3 % of full scale (nominal) Shunt calibration data Included termination (std) 1,83 m [5 ft] cable with balance board 4 Mechanical Maximum allowable load 1 Weight Material Stainless steel full scale Natural frequency Specifications subject to change. Questions? Contact us at either , 205

64 Option codes Wiring codes Load range Temperature compensation Internal amplifiers termination termination orientation Special calibration Shock and vibration Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see com/tmsensor-ship for updated listings. 150 g, 250 g, 500 g, 1000 g, 5 lb, 10 lb, 25 lb, 50 lb, 100 lb, 250 lb, 500 lb, 1000 lb 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 1e. -20 F to 200 F 5 1f. 70 F to 250 F 5 2u. Unamplified, mv/v output 5 ft integral cable with balance board 4 6a. Bendix PTIH-10-6P - (or equivalent) 6 pin (max. 120 C) on end of cable 6e. Integral cable: Teflon 6v. Phoenix connector on end of cable 15d. Connector on end of cable 30a. Compression testing only, positive in compression 30b. Tension and compression testing only, positive in tension 30c. Compression testing only, negative in compression 44a. Shock and vibration resistance Cable Red Black Green White Deflections and ringing frequencies Capacity Unamplified (+) excitation (-) excitation (-) output (+) output Deflection at full scale (10-3 in) Ringing frequency (khz) Weight Weight with cable 150 g g [0.011 lb] 13 g [0.029 lb] g g [0.011 lb] 13 g [0.029 lb] g g [0.011 lb] 13 g [0.029 lb] g g [0.011 lb] 13 g [0.029 lb] lb g [0.011 lb] 13 g [0.029 lb] lb g [0.011 lb] 13 g [0.029 lb] lb g [0.011 lb] 13 g [0.029 lb] 150 Max. allowable load 1 (% FS) Mounting dimensions and characteristics s Ø D T H A B 150, 250, 500, 1000 g; 5, 10, 25, 50, 100 lb 12,7 mm [0.50 in] 250, 500, 1000 lb 19,05 mm [0.75] #4-40 UNC 7,37 mm [0.29 in] 1/4-28 UNF 9,65 mm [0.38 in] 4,83 mm [0.19 in] 7,87 mm [0.31 in] 4,57 mm [0.18 in] 7,87 mm [0.31 in] 50 lb g [0.011 lb] 13 g [0.029 lb] lb g [0.011 lb] 13 g [0.029 lb] lb g [0.041 lb] 27 g [0.06 lb] lb g [0.041 lb] 27 g [0.06 lb] lb g [0.041 lb] 27 g [0.06 lb] 150 Typical system diagram Special requirements (consult factory) Have a special requirement? New case pressure, different cable lengths, electrical connectors, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. 206 Questions? Contact us at either , Specifications subject to change.

65 Model 53 Low Cost Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: AL131 AT 1b Order code code Option code Order codes AL131 Mode 53 low cost load cell 5 lb to lb Stainless steel Mini footprint Button style design mv/v output Notes 1. Allowable maximum loads maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 3. Dimension H may increase with option 6i. Consult factory. Maximum temperature is 180 F. 4. TEDS available with integral cable units only. 5. This unit calibrated to Imperial (non-metric) units. 6. Signature calibration only available as inline module. AT AV BL BN BR CN CR CV DL 5 lb 10 lb 25 lb 50 lb 100 lb 250 lb 500 lb 1000 lb 2000 lb Specifications Performance Load ranges 5 5 lb to lb Linearity (max.) ±0.5 % full scale Hysteresis (max.) ±0.3 % full scale Non-repeatability (max.) ±0.1 % full scale Output (tolerance) 2 mv/v (nominal) Operation Compression Resolution Infinite Environmental Temperature, operating -54 C to 121 C [-65 F to 250 F] Temperature, compensated 15 C to 71 C [60 F to 160 F] Temperature effect, zero % full scale/ F Temperature effect, span 0.01 % full scale/ F Strain gage type Bonded foil Excitation (calibration) 5 lb to 100 lb 5 Vdc 250 lb to lb 10 Vdc Insulation resistance Vdc Bridge resistance (tolerance) 350 ohm (nominal) Zero balance (tolerance) ±1 % full scale Shunt calibration data Included termination (std) Teflon cable 1.83 m [5 ft] Mechanical Weight Material 17-4 PH stainless steel Maximum allowable load 150 % full scale 1 Deflection full scale Natural frequency DN DP DR DT DV EJ EL EN EP 3000 lb 4000 lb 5000 lb 7500 lb lb lb lb lb lb Specifications subject to change. Questions? Contact us at either , 207

66 Option codes s lb 5, 10, 25, 50, , 500, 1000, , 4000, 5000, 7500, , 20000, D1 mm D2 mm H mm 25,4 [1.00] 5,33 [0.21] 15,75 [0.62] 31,75 [1.25] 38,1 [1.50] 10,16 [0.40] 50,8 [2.00] 15,24 [0.60] ,2 [3.00] 19,81 [0.78] Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see honeywell.com/tmsensor-ship for updated listings. Load ranges 5, 10, 25, 50, 100, 250, 500, 1000, 2000, 3000, 4000, 5000, 7500, 10000, 15000, 20000, 30000, lb Temperature compensation Internal amplifiers termination Special calibration Shock and vibration 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 1d. -20 F to 130 F 1e. -20 F to 200 F 1f. 70 F to 250 F 2u. Unamplified, mv/v output 6d. Microtec DR-4S-4H 4-pin 6e. Integral cable: Teflon 6f. Integral cable: PVC 6g. Integral cable: Neoprene 9a. 10 point (5 up/5 down) 20 % 68 F 9b. 20 point (10 up/10 down) 10 % 68 F 44a. Shock and vibration resistance Interfaces 53e. Signature calibration 6 53t. TEDS IEEE module 4 Mounting dimensions and characteristics L mm A in 1g. 70 F to 325 F 1h. 70 F to 400 F 1i. -65 F to 250 F 1j. 0 C to 50 C 1k. -20 C to 85 C 1m. -25 C to 110 C 6h. Integral cable: Silicone 6i. Integral underwater cable 3 6v. Phoenix connector on end of cable B mm G mm 1,27 [0.05] #4-40 UNC 5,59 [0.22] 19,05 [0.750] 8,13 [0.32] 9,91 [0.39] 1,78 [0.07] #6-32 UNC 6,35 [0.25] 25,4 [1.000] 16,0 [0.63] 2,03 [0.08] #6-32 UNC 6,35 [0.25] 31,75 [1.250] 25,4 [1.00] 3,05 [0.12] #6-32 UNC 6,35 [0.25] 41,28 [1.625] 38,1 [1.50] 4,57 [0.18] #6-32 UNC 6,35 [0.25] 60,33 [2.375] Wiring codes Cable Red Black Green White Deflections and ringing frequencies Capacity (lb) Unamplified (+) excitation (-) excitation (-) output (+) output full scale (in) Typical system diagram Natural ringing frequency (Hz) [0.13] [0.13] [0.136] [0.138] [0.141] [0.158] [0.158] [0.165] [0.17] [0.30] Weight with cable g [lb] [0.304] [0.306] [0.313] [0.32] [0.811] [0.820] [0.831] [2.8] Special requirements (consult factory) Have a special requirement? New diameter cable, different cable lengths, radiation proof, psi, output options, temperature settings, TEDS IEEE modules, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. 208 Questions? Contact us at either , Specifications subject to change.

67 Model 53E Low Cost/ OEM Compression Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: 53E 100N0 1J Order codes 53E Order code code Option code Low cost OEM compression load cell Deflections & ringing frequencies 20 N to 200 kn range Stainless steel construction Often ideal for OEM applications IP68 version available mv/v output Notes 1. Allowable maximum loads - maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc) should always be designed with safety redundant load paths. 3. Dimension H will increase with option 6i. 4. Varies by capacity, consult factory 5. TEDS available with integral cable units only. 6. This unit is calibrated to Metric (non-imperial) units. 7. Signature calibration only available as inline module. 020N0 050N0 100N0 200N0 500N0 01KN0 02KN0 05KN0 10KN0 20KN0 50KN0 200KN0 20 N 50 N 100 N 200 N 500 N 1 kn 2 kn 5 kn 10 kn 20 kn 50 kn 200 kn Specifications Capacity Natural ringing frequency (Hz) 20 N N N N N kn kn kn kn kn kn kn Weight (g) Performance Load ranges 6 20 N to 200 kn Linearity (max.) ±0.5 % full scale Hysteresis (max.) ±0.3 % full scale Non-repeatability (max) ±0.1 % full scale Output (tolerance) 2 mv/v (nominal) Operation Compression Resolution Infinite Environmental Temperature, operating -55 C to 120 C [-67 F to 248 F] Temperature, compensated 15 C to 70 C [59 F to 158 F] Temperature effect, zero 0.01% full scale/ C Temperature effect, span 0.02% reading/ C Strain gage type Bonded foil Excitation (calibration) 20 N to 500 N 5 Vdc 1 kn to 200 kn 10 Vdc Insulation resistance Vdc Bridge resistance (tolerance) 350 ohm (nominal) Zero balance (tolerance) ±1 % of full scale termination (std) 1,5 m; four-core (shielded) ptfe cable incorporating a spring strain relief Mechanical Maximum allowable load 150 % FS 1 Weight Material 17-4 PH stainless steel Deflection full scale 0,07 mm [0.003 in] Natural frequency Specifications subject to change. Questions? Contact us at either , 209

68 Option codes Load range Temperature compensation Internal amplifiers termination Special calibration Shock and vibration Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see honeywell.com/tmsensor-ship for updated listings. 20, 50, 100, 200, 500, 1K, 2K, 5K, 10K, 20K, 50K, 200K N 15 C to 70 C 1j. 0 C to 50 C 1k. -20 C to 85 C 1m. -25 C to 110 C 2u. Unamplified, mv/v output 1,5 m; four-core (shielded) P.T.F.E. cable 6d. Microtec DR-4S-4H 4-pin (max. 120 C) 6f. Integral cable: PVC 6g. Integral cable: Neoprene 6h. Integral cable: Silicone 6i. Integral underwater cable 3 6v. Phoenix connector on end of cable 9a. 10 point (5 up/5 down) 20 % 20 C [68 F] 9b. 20 point (10 up/10 down) 10 % 20 C [68 F] 44a. Shock and vibration resistance Wiring codes Cable Unamplified Red (+) excitation Black (-) excitation Green (-) output White (+) Output Typical system diagram Interfaces 53e. Signature calibration 7 53t. TEDS IEEE module 5 Mounting dimensions and characteristics code 20 N 020N0 25 mm [0.98 in] 50 N 050N0 25 mm [0.98 in] 100 N 100N0 25 mm [0.98 in] 200 N 200N0 25 mm [0.98 in] 500 N 500N0 25 mm [0.98 in] 1 kn 01KN0 32 mm [1.26 in} 2 kn 02KN0 32 mm [1.26 in] 5 kn 05KN0 32 mm [1.26 in] 10 kn 10KN0 32 mm [1.26 in] 20 kn 20KN0 38 mm [1.5 in] 50 kn 50KN0 38 mm [1.5 in] 200 kn 200KN0 76 mm [3 in] D1 D2 H L A B C 5 mm [0.2 in] 5 mm [0.2 in] 5 mm [0.2 in] 5 mm [0.2 in] 5 mm [0.2 in] 8 mm [0.31 in] 8 mm [0.31 in] 8 mm [0.31 in] 8 mm [0.31 in 11 mm [0.43 in] 11 mm [0.43 in] 20 mm [0.79 in] 16 mm [0.63 in] 16 mm [0.63 in] 16 mm [0.63 in] 16 mm [0.63 in] 16 mm [0.63 in] 10 mm [0.39 in] 10 mm [0.39 in] 10 mm [0.39 in] 10 mm [0.39 in] 16 mm [0.63 in] 16 mm [0.63 in] 38 mm [1.5 in] 1 mm [0.04 in] 1 mm [0.04 in] 1 mm [0.04 in] 1 mm [0.04 in] 1 mm [0.04 in] 2 mm [0.08 in] 2 mm [0.08 in] 2 mm [0.08 in] 2 mm [0.08 in] 2 mm [0.08 in] 2 mm [0.08 in] 5 mm [0.2 in] M3x0.5 M3x0.5 M3x0.5 M3x0.5 M3x0.5 M4x0.7 M4x0.7 M4x0.7 M4x0.7 M4x0.7 M4x0.7 M4x0.7 6 mm [0.24 in] 6 mm [0.24 in] 6 mm [0.24 in] 6 mm [0.24 in] 6 mm [0.24 in] 5 mm [0.2 in] 5 mm [0.2 in] 5 mm [0.2 in] 5 mm [0.2 in] 6 mm [0.24 in] 6 mm [0.24 in] 6 mm [0.24 in] 19 mm [0.75 in] 19 mm [0.75 in] 19 mm [0.75 in] 19 mm [0.75 in] 19 mm [0.75 in] 25 mm [0.98 in] 25 mm [0.98 in] 25 mm [0.98 in] 25 mm [0.98 in] 32 mm [1.26 in] 32 mm [1.26 in] 60 mm [2.36 in] Special requirements (consult factory) Have a special requirement? New diameter cable, different cable lengths, radiation proof, psi, output options, temperature settings, TEDS IEEE modules, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. 210 Questions? Contact us at either , Specifications subject to change.

69 Model LFH-7I (Top Hat) Subminiature Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: BL351 DL 1b Order code code Option code Order codes BL351 Model LFH-7I (top hat) subminiature load cell 250 lb to 10,000 lb range Stainless steel Column construction mv/v output 1 % accuracy CN CR CV DL DN DP DR DT DV 250 lb 500 lb 1000 lb 2000 lb 3000 lb 4000 lb 5000 lb 7500 lb lb Notes 1. Accuracies stated are expected for best-fit straight line for all errors including linearity, hysteresis and repeatability through zero. 2. Allowable maximum loads maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 4. This unit calibrated to Imperial (non-metric) units. Specifications Performance Load ranges lb to lb Accuracy ±0.7 % full scale 1 Tolerance on output 1.5 mv/v to 2.5 mv/v Operation Compression only Environmental Temperature, operating -54 C to 121 C [-65 F to 250 F] Temperature, compensated 15 C to 71 C [60 F to 160 F] Storage temperature -70 C to 149 C [-100 F to 300 F] Temperature effect, zero 0.01 % full scale/ F Temperature effect, span 0.01 % full scale/ F (nominal) Strain gage type Excitation (calibration) Insulation resistance Bridge resistance Zero balance termination (std) Bonded foil 5 Vdc Vdc 350 ohm 5 % max. Cable (1,83 m [5 ft]) Mechanical Maximum allowable load 150 % full scale 2 Weight Material 17-4 PH stainless steel Deflection full scale Natural frequency Specifications subject to change. Questions? Contact us at either , 211

70 Option codes Load range Temperature compensation Internal amplifiers termination Special calibration Shock and vibration Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see com/tmsensor-ship for updated listings. 250, 500, 1000, 2000, 3000, 4000, 5000, 7500, lb 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 1d. -20 F to 130 F 1e. -20 F to 200 F 1f. 70 F to 250 F 1j. 0 C to 50 C 1k. -20 C to 85 C 1m. -25 C to 110 C 2u. Unamplified, mv/v output 6e. Integral cable: Teflon 6h. Integral cable: Silicone 6v. Phoenix connector on end of cable 15d. Connector on end of cable 9a. 10 point (5 up/5 down) 20 % 70 F 9b. 20 point (10 up/10 down) 10 % 70 F 44a. Shock and vibration resistance Wiring codes Connector Unamplified Red (+) excitation Black (-) excitation Green (-) output White (+) output Deflections and ringing frequencies Capacity Deflection at full scale Ringing frequency (khz) Weight 250 lb 0,0127 mm [ in] g [0.022 lb] 500 lb 0,0127 mm [ in] g [0.022 lb] 1000 lb 0,03 mm [0.001 in] g [0.022 lb] 2000 lb 0,03 mm [0.001 in] g [0.022 lb] 3000 lb 0,03 mm [0.001 in] g [0.022 lb] 5000 lb 0,03 mm [0.001 in] g [0.066 lb] 7500 lb 0,038 mm [ in] g [0.066 lb] lb 0,04 mm [0.002 in] g [0.066 lb] Mounting dimensions and characteristics s ØD1 mm ØD2 mm H mm F mm W mm 250 lb 12,7 [0.50] 6,86 [0.27] 9,65 [0.38] 3,3 [0.13] 10,92 [0.43] 500 lb 12,7 [0.50] 7,11 [0.28] 9,65 [0.38] 3,3 [0.13] 10,92 [0.43] 1000 lb 12,7 [0.50] 7,87 [0.31] 9,65 [0.38] 3,3 [0.13] 10,92 [0.43] 2000 lb 12,7 [0.50] 10,41 [0.41] 9,65 [0.38] 3,3 [0.13] 10,92 [0.43] 3000 lb 12,7 [0.50] 11,43 [0.45] 9,65 [0.38] 3,3 [0.13] 11,68 [0.46] 5000 lb 16,00 [0.63] 13,46 [0.53] 15,24 [0.60] 5,84 [0.23] 12,95 [0.51] 7500 lb 22,35 [0.88] 16,00 [0.63] 16,00 [0.63] 13,72 [0.54] 16,00 [0.63] lb 22,35 [0.88] 16,00 [0.63] 16,00 [0.63] 13,72 [0.54] 16,00 [0.63] Typical system diagram Special requirements (consult factory) Have a special requirement? New case pressure, different cable lengths, electrical connectors, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. 212 Questions? Contact us at either , Specifications subject to change.

71 Model 13 Subminiature Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: AL322 AT 1b Order codes AL322 Order code code Option code Model 13 subminiature load cell AL 150 g BL 25 lb 150 g to 1000 lb mv/v output Stainless steel Single diaphragm design AN AP AR AT AV 250 g 500 g 1000 g 5 lb 10 b BN BR CN CR CV 50 lb 100 lb 250 lb 500 lb 1000 lb Notes 1. Allowable maximum loads maximum load to be applied without damage. 2 Loads described allow for 100 % full scale axial loading with the bending loads specified. Torque loading maximum is without axial or other load. For any other combination, consult factory. 2. Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 3. A small, 2 in circuit board is included in the cable, 2 ft from the load cell. Do not remove this board. 4. Only for ranges greater-than-or-equal-to 1000 g. 5. Specifications may vary with this option. 6. This unit calibrated to Imperial (non-metric) units. Specifications Performance Load ranges 6 Linearity Hysteresis Non-repeatability Tolerance on output 150 g to 500 g 15 mv/v (nominal) 1000 g 1.5 mv/v (nominal) 5 lb to 1000 lb 2 mv/v (nominal) Operation Resolution Environmental Temperature, operating Temperature, compensated Temperature effect, zero Temperature effect, span 150 g, 250 g, 500 g, 1000 g, 5 lb, 10 lb, 25 lb, 50 lb, 100 lb, 250 lb, 500 lb, 1000 lb ±0.5 % full scale ±0.5 % full scale ±0.1 % full scale Compression only Infinite -54 C to 121 C [-65 F to 250 F] 15 C to 71 C [60 F to 160 F] 0.01 % full scale/ F 0.02 % reading/ F Strain gage type 150 g to 500 g Semiconductor 1000 g to 1000 lb Bonded foil Excitation (calibration) 5 Vdc Insulation resistance Vdc Bridge resistance (tolerance) 150 g to 500 g 500 ohm (nominal) 1000 g to 1000 lb 350 ohm (nominal) Zero balance (tolerance) ±3 % of full scale (nominal) Shunt calibration data Included termination (std) 1,83 m [5 ft] integral cable with balance board 3 Mechanical Maximum allowable load Weight Material full scale Stainless steel Specifications subject to change. Questions? Contact us at either , 213

72 Option codes Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see honeywell.com/tmsensor-ship for updated listings. Load range 150, 250, 500 g, 1000 g; 5, 10, 25, 50, 100, 250, 500, 1000 lb Temperature compensation Internal amplifiers Overload stops termination Special calibration Shock and vibration 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 1d. -20 F to 200 F 2u. Unamplified, mv/v output 4a. Overload stops 5 ft integral cable with balance board 3 6v. Phoenix connector on end of cable 15d. Connector on end of cable 9a. 10 point (5 up/5 down) 20 % 68 F 9b. 20 point (10 up/10 down) 10 % 68 F 44a. Shock and vibration resistance 1e. -20 F to 200 F 1j. 0 C to 50 C 1k. -20 C to 85 C 1m. -25 to 110 C Wiring code Cable Red Black Green White Deflections and ringing frequencies Capacity (lb) Unamplified (+) excitation (-) excitation (-) output (+) output Deflection at full scale (10-3 in) Weight Weight with cable 150 g g [0.002 lb] 9 g [0.019 lb] g g [0.002 lb] 9 g [0.019 lb] g g [0.002 lb] 9 g [0.019 lb] g g [0.002 lb] 9 g [0.019 lb] 150 Max. allowable load 1 (% FS) 5 lb g [0.002 lb] 9 g [0.019 lb] 150 Mounting dimensions and characteristics s D1 D2 H B SR 150, 250, 500, 1000 g; 5, 10, 25, 50 lb 9,65 mm [0.38 in] 100, 250 lb 12,7 mm [0.50 in] 500 lb, 1000 lb 19,05 mm [0.75] 2,29 mm [0.09 in] 3,05 mm [0.12] 6,35 mm [0.25 in] 3,3 mm [0.13 in] 3,81 mm [0.15 in] 6,35 mm [0.25 in] 0,69 mm [0.027 in] 0,51 mm [0.020 in] 0,64 mm [0.025 in] 6,35 mm [0.25 in] 12,7 mm [0.50 in] 12,7 mm [0.50 in] 10 lb g [0.002 lb] 9 g [0.019 lb] lb g [0.002 lb] 9 g [0.019 lb] lb g [0.002 lb] 9 g [0.019 lb] lb g [0.006 lb] 11 g [0.024 lb] lb g [0.006 lb] 11 g [0.024 lb] lb g [0.022 lb] 18 g [0.039 lb] lb g [0.022 lb] 18 g [0.039 lb] 150 Typical system diagram Special requirements (consult factory) Have a special requirement? New case pressure, different cable lengths, electrical connectors, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. 214 Questions? Contact us at either , Specifications subject to change.

73 Model 13E Subminiature Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: 13E 050N0 1j Order codes 13E Order code code Option code Model 13E subminiature load cell 000N5 0.5 N 100N0 100 N 001N5 1.5 N 200N0 200 N 0.5 N to 5 kn range mv/v output Stainless steel Fast dynamic response 002N5 005N0 010N0 020N0 050N0 2.5 N 5 N 10 N 20 N 50 N 500N0 01KN0 02KN0 05KN0 500 N 1 kn 2 kn 5 kn Notes 1. Allowable maximum loads maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 3. A small 50 mm long x 2 mm thick circuit board is located approximately 60 cm from cell body. Do not remove this board. 4. Only for ranges greater-than-or-equal-to 10 N. 5. Specifications may vary with this option. 6. This unit is calibrated to Metric (non-imperial) units. Specifications Performance Load ranges N to 5kN Linearity ±0.5 % full scale Hysteresis ±0.5 % full scale Non-repeatability ±0.1 % full scale Tolerance on output 0.5 N to 5 N 15 mv/v (nominal) 10 N 1.5 mv/v (nominal) 20 N to 5 kn 2 mv/v (nominal) Operation Resolution Environmental Temperature, operating Temperature, compensated Temperature effect, zero Temperature effect, span Protection rating Compression only Infinite -55 C to 120 C [-65 F to 248 F] 15 C to 70 C [60 F to 158 F] 0.02 % full scale/ C 0.04 % full scale/ C IP65 Strain gage type 0.5 N to 5 N Semiconductor 10 N to 5 kn Bonded foil Excitation (calibration) 5 Vdc Insulation resistance Vdc Bridge resistance (tolerance) 0.5 N to 5 N 500 ohm (nominal) 10 N to 5 kn 350 ohm (nominal) Zero balance (tolerance) ±3 % of full scale (nominal) Shunt calibration data Included termination (std) 1,5 m integral cable with balance board 3 Mechanical Maximum allowable load 150 % full scale 1 Weight Material Stainless steel full scale Specifications subject to change. Questions? Contact us at either , 215

74 Option codes Wiring codes Load range Temperature compensation Internal amplifiers termination connector orientation Load direction Shock and vibration Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see for updated listings. 0.5, 1.5, 2.5, 5, 10, 20, 50, 200, 500, 1K, 2K, 5K N 1a. 15 C to 70 C 1j. -65 C to 50 C 1k. -20 C to 85 C 2u. Unamplified, mv/v output 1,5 m integral cable with balance board 3 6a. Bendix PTIH-10-6P - (or equivalent) 6 pin (max. 120 C) on end of cable 6e. Integral cable: Teflon 6v. Phoenix connector on end of cable 15d. Connector on end of cable 30c. Negative in compression, compression testing only 44a. Shock and vibration resistance Cable Red Black Green White Deflections and ringing frequencies Capacity Unamplified (+) excitation (-) excitation (-) output (+) output Deflection at full scale (mm) Weight Weight with cable 0.5 N g [0.002 lb] 9 g [0.019 lb] 1.5 N g [0.002 lb] 9 g [0.019 lb] 2.5 N g [0.002 lb] 9 g [0.019 lb] 5 N g [0.002 lb] 9 g [0.019 lb] 10 N g [0.002 lb] 9 g [0.019 lb] 20 N g [0.002 lb] 9 g [0.019 lb] Mounting dimensions and characteristics s code OD mm D1 mm H mm B mm SR mm 0.5 N 000N5 9,7 [0.38] 2,3 [0.09] 3,3 [0.13] 0,7 [0.03] 6 [0.24] 1.5 N 001N5 9,7 [0.38] 2,3 [0.09] 3,3 [0.13] 0,7 [0.03] 6 [0.24] 2.5 N 002N5 9,7 [0.38] 2,3 [0.09] 3,3 [0.13] 0,7 [0.03] 6 [0.24] 5 N 005N0 9,7 [0.38] 2,3 [0.09] 3,3 [0.13] 0,7 [0.03] 6 [0.24] 10 N 010N0 9,7 [0.38] 2,3 [0.09] 3,3 [0.13] 0,7 [0.03] 6 [0.24] 20 N 020N0 9,7 [0.38] 2,3 [0.09] 3,3 [0.13] 0,7 [0.03] 6 [0.24] 50 N 050N0 9,7 [0.38] 2,3 [0.09] 3,3 [0.13] 0,7 [0.03] 6 [0.24] 100 N 100N0 9,7 [0.38] 2,3 [0.09] 3,3 [0.13] 0,7 [0.03] 6 [0.24] 200 N 200N0 9,7 [0.38] 2,2 [0.086] 3,3 [0.13] 0,7 [0.03] 6 [0.24] 500 N 500N0 12,7 [0.50] 3,0 [0.12] 3,8 [0.15] 0,5 [0.02] 13 [0.51] 1 kn 01KN0 12,7 [0.50] 3,0 [0.12] 3,8 [0.15] 0,5 [0.02] 13 [0.51] 2 kn 02KN0 19,1 [0.75] 6,4 [0.25] 6,4 [0.25] 0,6 [0.023] 13 [0.51] 5 kn 05KN0 19,1 [0.75] 6,4 [0.25] 6,4 [0.25] 0,6 [0.023] 13 [0.51] 50 N g [0.002 lb] 9 g [0.019 lb] 100 N g [0.002 lb] 9 g [0.019 lb] 200 N g [0.002 lb] 9 g [0.019 lb] 500 N g [0.006 lb] 11 g [0.024 lb] 1 kn g [0.006 lb] 11 g [0.024 lb] 2 kn g [0.022 lb] 18 g [0.039 lb] 5 kn g [0.022 lb] 18 g [0.039 lb] Typical system diagram Special requirements (consult factory) Have a special requirement? New case pressure, different cable lengths, electrical connectors, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. 216 Questions? Contact us at either , Specifications subject to change.

75 Model UG Ultra Precision Universal Canister Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: BL122 DL 1b Order codes BL122 Order code code Option code Model UG ultra precision universal canister load cell BR 100 lb DV lb CN 250 lb EJ lb 100 lb to lb Stainless steel All-welded design 0.03 % linearity Intrinsically safe available (2N option only) 10 CE approved 11 CR CV DL DN DP DR DT 500 lb 1000 lb 2000 lb 3000 lb 4000 lb 5000 lb 7500 lb EL EN EP ER ET FJ lb lb lb lb lb lb Notes 1. ±0.05% full scale less than or equal to 250 lb and greater than or equal to lb. 2. Allowable maximum loads - maximum load to be applied without damage Without damage loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 4. Standard calibration for tension/ compression load cells is in tension only. 5. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal provides 50 % (unamplified units), 75 % (4 ma to 20 ma threewire units) or 80 % (voltage amplified units) of full scale output for quick calibration. Shunt calibration comes standard with internal amplifier option 2b, 2c, 2t and 2j. 6. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown; W=White; G=Green. Color specifying cable and number or letter specifying connector. 7. No mating connector necessary for cable option. 8. Consult factory for extended temperature ranges. 9. Consult factory for TEDS availability with amplified models. 10. dependent; consult factory. Termination dependent; consult factory. 11. Internal amp and termination dependent; consult factory. 12. This unit calibrated to Imperial (non-metric) units ohm bridge required 14. Not available with amplified options. 15. Temperature 82 C [180 F] max., non-shielded standard, shielded available. 16. Cannot be used with options 1c, 1e, 1f, 1g, 1h, or 1i. Specifications Performance Load ranges lb to lb Non-linearity ±0.03 % full scale 1 Hysteresis ±0.03 % full scale 1 Non-repeatability ±0.02 % full scale Output (tolerance) 3 mv/v ±1 % Load direction Tension/compression 4 Resolution Infinite Creep (max.) 0.02 % (20 min.) Environmental Temperature, operating -34 C to 85 C [-30 F to 185 F] 5 Temperature, compensated 15 C to 71 C [60 F to 160 F] 5 Temperature, storage -73 C to 121 C [-100 F to 250 F] Temperature effect, zero % full scale/ F Temperature effect, span % full scale/ F Strain gage type Bonded foil Excitation (calibration) 10 Vdc Insulation resistance Vdc Bridge resistance 350 ohm Zero balance 1 % of full scale termination (std) MS3102E-14S-6P Mating connector (not included) MS3106A-14S-6S (AA121) Mechanical Maximum allowable load 150 % FS 2 Material Stainless steel Specifications subject to change. Questions? Contact us at either , 217

76 Option codes Mounting dimensions and characteristics s lb H mm ,85 [2.75] Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see honeywell.com/tmsensor-ship for updated listings. Load ranges 100, 250, 500, 1000, 2000, 3000, 4000, 5000, 7500, 10000, 15000, 20000, 30000, 50000, 75000, , lb Temperature compensation Internal amplifiers termination 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 1d. -20 F to 200 F 1e. -20 F to 200 F 1f. 70 F to 250 F 2b. ±5 Vdc 2c. 0 Vdc to 5 Vdc output 2j. 4 ma to 20 ma (three-wire) out 2k. 4 ma to 20 ma (two-wire) 13 6a. Bendix PTIH-10-6P (or equivalent) 6-pin (max. 250 F) 6b. MS connector MS3102E-14S-6P (mates with MS3106E-14S-6S) (max 160 F) 16 6e. Integral cable: Teflon Shunt calibration 8a. Precision internal resistor 14 Bridge resistance Special calibration Shock and vibration 12b ohm (foil) 11a. Square bridge 14 11b. Symmetrical bridge 14 11c. Square and symmetrical bridge 14 ØD1 mm ØD2 mm 50,8 [2.00] 16,00 [0.63] ØD3 mm 1g. 70 F to 325 F 14 1h. 70 F to 400 F 14 1i. -65 F to 250 F 14 1j. 0 C to 50 C 1k. -20 C to 85 C 1m. -25 C to 110 C 30a. Compression only calibration, positive in compression 30b. Tension and compression calibration, positive in tension 30c. Compression only calibration, negative in compression 44a. Shock and vibration resistance Interfaces 53e. Signature calibration 14 53t. TEDS IEEE module 9 2n (2N) 4 ma to 20 ma (wire) intrinsically safe 13 2t. 0 Vdc to 10 Vdc 2u. Unamplified, mv/v output 6g. Integral cable: Neoprene 6i. Submersible cable 15 6j. 1/2-14 conduit fitting with 5 ft of 4 conductor PVC cable 6q. Integral cable: Polyurethane A mm 48,26 [1.9] 2,29 [0.09] 3/8-24 UNF x 7/16 in T Internal amplifiers Amplifier specifications Output signal Input power (voltage) Input power (current) Freq. resp (amp) Power supply rej. Operating temp. Reverse voltage protection Short cir. protection Wiring code: connector (std) Wiring code: cable 5,6,7 Wiring codes Connector Voltage output: Option 2b Unamplified Voltage output: Option 2c ±5 V 0 V to 5 V or ±5 45 ma ±15 V or 26 Vdc to 32 Vdc 11 Vdc to 28 Vdc Voltage output: Option 2t 0 V to 10 V or ±10 45 ma 15 Vdc to 28 Vdc Current three-wire: Option 2j Current two-wire: Option 2k Intrinsically safe amp: Option 2n (2N)*** 4 ma to 20 ma 4 ma to 20 ma 4 ma to 20 ma 22 Vdc to 32 Vdc 15 Vdc to 40 Vdc 9 Vdc to 28 Vdc 45 ma 40 ma 40 ma 65 ma 4 ma to 28 ma 4 ma to 24 ma 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz 60 db 60 db 60 db 60 db 60 db 60 db -20 F to 185 F -20 F to 185 F -20 F to 185 F 0 F to 185 F 0 F to 185 F -20 F to 185 F Yes Yes Yes Yes Yes Yes Momentary Momentary Momentary Yes Yes Yes B Output common C Supply return E Shunt cal 1 F Shunt cal 2 Bl Output common G Supply return W (+) Output B Shunt cal 1 Br Shunt cal 2 B Output common** C Supply return ** E Shunt cal 1 F Shunt cal 2 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 B Output common** C Supply return** E Shunt cal 1 F Shunt cal 2 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 B Output common** C Supply return** E Shunt cal 1 F Shunt cal 2 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 B No connection C No connection E Case ground F No connection Bl (+) Output W Case ground * Black and green wires are internally connected. ** Pins B and C are internally connected. *** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. # B No connection C No connection E Case ground F No connection Bl (+) Output W Case ground 250, ,85 [2.75] 1000, 2000, 3000, ,90 [4.13] 50,8 [2.00] 16,00 [0.63] 63,5 [2.50] 19,05 [0.75] 48,26 [1.9] 4,57 [0.18] 3/8-24 UNF x 7/16 in 50,8 [2.00] 4,57 [0.18] 1/2-20 UNF x 5/8 in A B C (+) excitation (+) excitation (-) excitation 5000, 7500, , 20000, ,35 [5.88] 215,9 [8.50] 88,9 [3.50] 39,62 [1.56] 127 [5.00] 60,45 [2.38] 76,2 [3.00] 4,83 [0.19] 1-14 UNF x 1 1/8 in 109,22 [4.3] 16,00 [0.63] 1 1/2-12 UNF x 2 in D E F (-) excitation (-) output (+) output 50000, ,8 [12.00] , ,32 [15.80] 152,4 [6.00] 92,20 [3.63] 190,5 [7.5] 121,92 [4.8] 139,7 [5.5] 17,53 [0.69] 172,72 [6.8] 17,53 [0.69] 2-12 UNF x 2 1/2 in 3-8 UNF x 4 1/2 in Typical system diagram Special requirements (consult factory) Have a special requirement? New case pressure, different cable lengths, electrical connectors, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. 218 Questions? Contact us at either , Specifications subject to change.

77 Model Tension/Compression Canister Load Cell Optional dual bridge (not shown) Metric threads Resist fatigue failure Low failure rate Special structure design Capacities to N Bending moment resistance up to lb inches Up to lb of shear resistance Notes 1. This unit calibrated to Imperial (non-metric) units. How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code and the desired load range in lbs. For example: K Order code Order codes (lb) Model tension/compression load cell (Metric threads) 3130 Model 3130 tension/compression load cell (English threads) Specifications Performance Load range 1 2M, 3.5M, 5M N Non-linearity ±0.2 % of rated output Hysteresis ±0.2 % of rated output Repeatability ±0.05 % of rated output rated capacity ±2 mv/v (nominal) Operation Tension/compression Resolution Infinite Standard calibration Tension (+) and compression (-) Environmental Temperature, operating -54 C to 93 C [-65 F to 200 F] Temperature, compensated 21 C to 77 C [70 F to 170 F] Temperature effect, zero ±0.003 % of rated output/ F Temperature effect, output ±0.003 % of reading/ F Strain gage type Foil Excitation (maximum) 20 Vdc or Vac RMS Insulation resistance > Vdc Bridge resistance (tolerance) 700 ohm Number of bridges 1 or 2 Zero balance ±1.0 % termination MS-3102E-14S-5P Mechanical Static overload capacity 150 % of nominal capacity Material Carbon steel Fatigue life (0 to full fatigue load) 100 x 10 6 cycles Fatigue life (full fatigue tension to compression) 50 x 10 6 cycles Natural frequency below Mechanical characteristics Nominal load limit capacity F z lb N Static overload capacity (% of nominal capacity) Fatigue capacity (% of nominal capacity) Static extraneous load limits Shear F X or F Y (lb) Bending M X or M Y (lb-in) Torque M Z (lb-in) Deflection at nominal load limit (in) 500K 2M K 4530K 820K K 3.5M K 5450K 1050K K 5M K 6110K 1100K Ringing frequency (Hz) Specifications subject to change. Questions? Contact us at either , 219

78 SETUP LOAD CELLS Mounting dimensions and characteristics Model A cm B cm C cm D cm E cm F cm G cm H cm J cm K cm L cm M cm N cm P cm *Q cm *R cm ,75 [12.50] 3,81 [1.50] 17,78 [7.0] 5,08 [2.0] 1,91 [0.75] 32,29 [12.75] 31,12 [12.25] 15,88 [6.25] 13,34 [5.25] 2,54 [1.0] 19,86 [7.82] 6,35 [2.50] 24,15 [9.50] 8,89 [3.50] M42-3 [ ] M125-4 [5-8] * Q and R are metric thread measures * 3130 standard Q and R are English thread measures L For reference only M R THD. P DEEP BOTH ENDS Q THD. 2.0 DEEP 8 HOLES EQUALLY SPACED ON N DIA. BOTH ENDS RECEP. MS-3102E-14S-5P H 1.0 J DIA. BOTH ENDS G DIA. BOTH ENDS F DIA. 3/8 16 THD. 5/8 DEEP 2 HOLES AT 180 LIFTING E B D C A SPANNER WRENCH HOLES 13/32 DIA. 3/8 DEEP 4 HOLES EQUALLY SPACED BOTH ENDS Typical system diagram In-Line Amplifiers (Used with unamplified units only) Amplifier Output Universal In-Line Amplifiers UV +/-5 VDC UV-10 +/-10 VDC UBP 0 +/-5 VDC U3W 4-20mA (3 wire) U2W 4-20mA (2 wire) DIN rail Mount In-Line Amplifiers DV /- 5 VDC (3 wire) DA mA (3 wire) DV10 0 +/- 10 VDC (3 wire) Customer Supplied Chart Recorder Alarm Panel Data Acquisition Computer PLC Power Supply Wiring codes Honeywell In-Line Amplifier Output Input Serial Number Wire Red Black Green White (+) excitation (-) excitation (+) output (-) output MODEL 3130 Display Units SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH PSD OR lb. L1 L2 L3 L4 VALUE CLEAR CHAN TARE UP DOWN ENTER EXIT Mating Connectors & Cables 064-LW13621 Mating connector XX* Mating connector and six conductor cable (unamplified unit with sense leads but not shunt cal) XX** Mating connector (MS - 5 pin) and four conductor cable (unamplified sensor without sense leads) XX** Mating connector ( MS 5 pin ) & 6 conductor cable for connection to XX** Mating connector ( MS 5 pin ) & 4 conductor cable for connection to 7541 * XX represents length in feet 100ft maximum ** XX represents length in feet 20ft maximum 220 Questions? Contact us at either , Specifications subject to change.

79 Model 3156 Tension/Compression Canister Load Cell English threads Resist fatigue failure Minimize bending strains Dual bridges available on all models Special structure design Enhanced resistance to side loads and bending moments Notes 1. This unit calibrated to Imperial (non-metric) units. How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code and the desired load range in lbs. For example: K Order code Order codes (lb) 3156 Model 3156 tension/compression canister load cell (English threads) Model tension/compression canister load cell (Metric threads) Specifications Performance Load range 1 100K, 200K, 500K, 750K N Non-linearity ±0.2 % of rated output Hysteresis ±0.2 % of rated output Repeatability ±0.05 % of rated output rated capacity ±2 mv/v (nominal) Operation Tension/compression Resolution Infinite Standard calibration Tension (+) and compression (-) Environmental Temperature, operating -54 C to 93 C [-65 F to 200 F] Temperature, compensated 21 C to 77 C [70 F to 170 F] Temperature effect, zero ±0.003 % of rated output/ F Temperature effect, output ±0.003 % of reading/ F Strain gage type Foil Excitation (maximum) 30 Vdc or Vac RMS Insulation resistance > Vdc Bridge resistance (tolerance) 350 ohm Number of bridges 1 or 2 Zero balance ±1.0 % termination MS-3102E-14S-5P Mechanical Static overload capacity 150 % of nominal capacity Material Carbon steel Fatigue life (0 to full fatigue load) 100 x 10 6 cycles Fatigue life (full fatigue tension to compression) 50 x 10 6 cycles Natural frequency below Mechanical characteristics Nominal load limit capacity F z lb N Static overload capacity (% of nominal capacity) Fatigue capacity (% of nominal capacity) Static extraneous load limits Shear F X or F Y (lb) Bending M X or M Y (lb-in) Torque M Z (lb-in) Deflection at nominal load limit (in) 25K 100K K 68K 10K K 200K K 130K 20K K 500K K 220K 85K K 750K K 220K 85K Ringing frequency (Hz) Specifications subject to change. Questions? Contact us at either , 221

80 Output Input Serial Number SETUP LOAD CELLS Mounting dimensions and characteristics Model A cm B cm C cm D cm E cm F cm G cm H cm J cm K cm L cm M cm N cm * P cm * R cm ,78 [7] 13,97 [5.50] 8,89 [3.50] 5,41 [2.13] 12,07 [4.75] 2,87 [1.13] 13,84 [5.45] 9,12 [3.59] 8,89 [3.50] 0,79 [0.31] 0,95 [0.38] 5,08 [2] 3,18 [1.25] M20 x 2.5 [3/4-10] M52 x 2 [2-12] * P and R are metric thread measures * 3156 standard P and R are English thread measures SPANNER WRENCH HOLES L DIA. K DEEP 3 HOLES EQUALLY SPACED BOTH ENDS R THD. M DEEP BOTH ENDS H RECEP. MS-3102E-14S-5P P THD. N DEEP 6 HOLES EQUALLY SPACED ON J DIA. BOTH ENDS Typical system diagram In-Line Amplifiers (Used with unamplified units only) Amplifier Output Universal In-Line Amplifiers UV +/-5 VDC UV-10 +/-10 VDC UBP 0 +/-5 VDC U3W 4-20mA (3 wire) U2W 4-20mA (2 wire) DIN rail Mount In-Line Amplifiers DV /- 5 VDC (3 wire) DA mA (3 wire) DV10 0 +/- 10 VDC (3 wire) Customer Supplied Chart Recorder Alarm Panel Data Acquisition Computer PLC Power Supply G Honeywell In-Line Amplifier A E F C MODEL 3156 Display Units SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH PSD For reference only D DIA. B OR lb. L1 L2 L3 L4 Wiring codes Wire Red (+) excitation Black (-) excitation Green (+) output White (-) output * XX represents length in feet 100ft maximum ** XX represents length in feet 20ft maximum VALUE CLEAR CHAN TARE UP DOWN ENTER EXIT Mating Connectors & Cables 064-LW13621 Mating connector XX* Mating connector and six conductor cable (unamplified unit with sense leads but not shunt cal) XX** Mating connector (MS - 5 pin) and four conductor cable (unamplified sensor without sense leads) XX** Mating connector ( MS 5 pin ) & 6 conductor cable for connection to XX** Mating connector ( MS 5 pin ) & 4 conductor cable for connection to Questions? Contact us at either , Specifications subject to change.

81 Model 3127 Tension/Compression Canister Load Cell Optional dual bridge not shown Metric threads Resist fatigue failure Low failure rate Special structure design N capacity Bending moment resistance of lb inches lb of shear resistance Notes 1. This unit calibrated to Imperial (non-metric) units. How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code and the desired load range in lbs. For example: K Order code Order codes (lb) 3127 Model 3127 tension/compression canister load cell (English threads) Model tension/compression canister load cell (Metric threads) Specifications Performance Load range 1 10M N Non-linearity ±0.2 % of rated output Hysteresis ±0.2 % of rated output Repeatability ±0.05 % of rated output rated capacity ±2 mv/v (nominal) Operation Tension/compression Resolution Infinite Standard calibration Tension (+) and compression (-) Environmental Temperature, operating -54 C to 93 C [-65 F to 200 F] Temperature, compensated 21 C to 77 C [70 F to 170 F] Temperature effect, zero ±0.003 % of rated output/ F Temperature effect, output ±0.003 % of reading/ F Strain gage type Foil Excitation (maximum) 20 Vdc or Vac RMS Insulation resistance > Vdc Bridge resistance (tolerance) 700 ohm Number of bridges 1 or 2 Zero balance ±1.0 % termination MS-3102E-14S-5P Mechanical Static overload capacity 150 % of nominal capacity Material Carbon steel Fatigue life (0 to full fatigue load) 100 x 10 6 cycles Fatigue life (full fatigue tension to compression) 50 x 10 6 cycles Natural frequency below Mechanical characteristics Nominal load limit capacity F z lb N Static overload capacity (% of nominal capacity) Fatigue capacity (% of nominal capacity) Static extraneous load limits Shear F X or F Y (lb) Bending M X or M Y (lb-in) Torque M Z (lb-in) Deflection at nominal load limit (in) 2000K 10M K 7500K 1500K Ringing frequency (Hz) Specifications subject to change. Questions? Contact us at either , 223

82 SETUP LOAD CELLS Mounting dimensions and characteristics Model A cm B cm C cm D cm E cm F cm G cm H cm J cm K cm L cm M cm N cm P cm Q cm R cm S cm *T cm *U cm ,15 [22.50] 20,32 [8.0] 16,51 [6.50] 6,35 [2.50] 44,78 [17.63] 43,18 [17] 28,58 [11.25] 16,51 [6.50] 24,77 [9.75] 7,62 [3] 30,48 [12] 3,81 [1.50] 6,35 [2.50] 8,89 [3.50] 20,96 [8.25] 1,03 [0.41] 1,27 [0.50] M150-4 [6-8] M42-3 [ ] * T and U are metric thread measures * 3127 standard T and U are English thread measures RECEP. MS-3102E-14S-5P T THD. Q DEEP BOTH ENDS For reference only K DIA. J U THD. P DEEP, 12 HOLES EQUALLY SPACED ON L DIA. BOTH ENDS SPANNER WRENCH HOLES R DIA. S DEEP 6 HOLES EQUALLY SPACED BOTH ENDS G H DIA. BOTH ENDS N F DIA. BOTH ENDS E 3/4-10 THD. M DEEP 2 HOLES AT 180 LIFTING C B D A Typical system diagram In-Line Amplifiers (Used with unamplified units only) Amplifier Output Universal In-Line Amplifiers UV +/-5 VDC UV-10 +/-10 VDC UBP 0 +/-5 VDC U3W 4-20mA (3 wire) U2W 4-20mA (2 wire) DIN rail Mount In-Line Amplifiers DV /- 5 VDC (3 wire) DA mA (3 wire) DV10 0 +/- 10 VDC (3 wire) Customer Supplied Chart Recorder Alarm Panel Data Acquisition Computer PLC Power Supply Wiring codes Honeywell In-Line Amplifier Output Input Serial Number Wire Red (+) excitation Display Units Black Green White (-) excitation (+) output (-) output MODEL 3127 SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH PSD OR lb. L1 L2 L3 L4 VALUE CLEAR CHAN TARE UP DOWN ENTER EXIT Mating Connectors & Cables 064-LW13621 Mating connector XX* Mating connector and six conductor cable (unamplified unit with sense leads but not shunt cal) XX** Mating connector (MS - 5 pin) and four conductor cable (unamplified sensor without sense leads) XX** Mating connector ( MS 5 pin ) & 6 conductor cable for connection to XX** Mating connector ( MS 5 pin ) & 4 conductor cable for connection to 7541 * XX represents length in feet 100ft maximum ** XX represents length in feet 20ft maximum 224 Questions? Contact us at either , Specifications subject to change.

83 Model Tension/ Compression Canister Load Cell Metric threads Resist fatigue failure Low failure rate Special structure design N capacity Bending moment resistance of lb inches lb of shear resistance Notes 1. This unit calibrated to Imperial (non-metric) units. How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code and the desired load range in lbs. For example: K Order code Order codes (lb) Model tension/compression canister load cell (Metric threads) Model tension/compression canister load cell (English threads) Specifications Performance Load range , , N Non-linearity ±0.2 % of rated output Hysteresis ±0.2 % of rated output Repeatability ±0.05 % of rated output rated capacity ±2 mv/v (nominal) Operation Tension/compression Resolution Infinite Standard calibration Tension (+) and compression (-) Environmental Temperature, operating -54 C to 93 C [-65 F to 200 F] Temperature, compensated 21 C to 77 C [70 F to 170 F] Temperature effect, zero ±0.003 % of rated output/ F Temperature effect, output ±0.003 % of reading/ F Strain gage type Foil Excitation (maximum) 20 Vdc or Vac RMS Insulation resistance > Vdc Bridge resistance (tolerance) 350 ohm Number of bridges 1 or 2 Zero balance ±1.0 % termination MS-3102E-14S-5P Mechanical Static overload capacity 150 % of nominal capacity Material Carbon steel Fatigue life (0 to full fatigue load) 100 x 10 6 cycles Fatigue life (full fatigue tension to compression) 50 x 10 6 cycles Natural frequency below Mechanical characteristics Nominal load limit capacity F z Static extraneous load limits lb N Static overload capacity (% of nominal capacity) Fatigue capacity (% of nominal capacity) Shear F X or F Y (lb) Bending M X or M Y (lb-in) Torque M Z (lb-in) Deflection at nominal load limit (in) Ringing frequency (Hz) 150K 750K K 625K 150K K 1M K 730K 260K K 1.5M K 840K 236K Specifications subject to change. Questions? Contact us at either , 225

84 Mounting dimensions and characteristics Wiring codes Model A cm B cm C cm D cm E cm F cm ,4 [10] 17,78 [7] 3,81 [1.50] 10,8 [4.25] 19,05 [7.50] 12,70 [5] G cm H cm J cm K cm L cm *M cm *N cm 6,35 [2.50] 12,7 [5] 3,81 [1.50] 13,97 [5.50] 8,41 [3.31] M27-2 [1-8] M76-2 [3-12] Wire Red Black Green White (+) excitation (-) excitation (+) output (-) output * M and N are metric thread measures * standard M and N are English thread measures E Typical system diagram N THD. 3.0 DEEP BOTH ENDS F G M THD. 1/2 DEEP 8 HOLES EQUALLY SPACED ON H DIA. D RECEP. MS-3102E-14S-5P C L DIA. B DIA. J K A SPANNER WRENCH HOLES 13/32 DIA. 3/8 DEEP 6 HOLES EQUALLY SPACED AT BOTH ENDS In-Line Amplifiers (Used with unamplified units only) Amplifier Output Universal In-Line Amplifiers UV +/-5 VDC UV-10 +/-10 VDC UBP 0 +/-5 VDC U3W 4-20mA (3 wire) U2W 4-20mA (2 wire) DIN rail Mount In-Line Amplifiers DV /- 5 VDC (3 wire) DA mA (3 wire) DV10 0 +/- 10 VDC (3 wire) Customer Supplied Chart Recorder Alarm Panel Data Acquisition Computer PLC Power Supply For reference only Honeywell In-Line Amplifier Output Input Serial Number Display Units MODEL 3127 SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH PSD OR lb. L1 L2 L3 L4 VALUE CLEAR CHAN TARE UP DOWN SETUP ENTER EXIT Mating Connectors & Cables 064-LW13621 Mating connector XX* Mating connector and six conductor cable (unamplified unit with sense leads but not shunt cal) XX** Mating connector (MS - 5 pin) and four conductor cable (unamplified sensor without sense leads) XX** Mating connector ( MS 5 pin ) & 6 conductor cable for connection to XX** Mating connector ( MS 5 pin ) & 4 conductor cable for connection to 7541 * XX represents length in feet 100ft maximum ** XX represents length in feet 20ft maximum 226 Questions? Contact us at either , Specifications subject to change.

85 Model MPB High Capacity Compact Compression Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: BL515 ET 1j Order codes BL515 Order code code Option code Model MPB high capacity compact compression load cell 1 ton to 1000 ton range Stainless steel mv/v output 0.25 % accuracy CE approved Notes 1. For standard configuration with spherical radius, a hardened surface is recommended to maintain the best loading conditions. RC42 is recommended minimum hardness. Bearing lubricant at loading interface recommended for maximum life. 2. Accuracies stated are expected for best-fit, straight-line for all errors including linearity, hysteresis and non-repeatability thru zero. 3. Allowable maximum loads Maximum load to be applied without damage Without damage loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 5. Special wiring code. 6. Not available with option 1e, 1f, 1g, 1h, or 1i. 7. Amplifier option not available with low ranges. Consult factory. 8. Consult factory for TEDS availability with amplified models. 9. This unit calibrated to Imperial (non-metric) units. 10. Non-amplified only ohm bridge required. Mounting dimensions and characteristics DL DR DV EL EP 1 ton 2.5 ton 5 ton 10 ton 25 ton Specifications ET FL FR FT FV Performance Load ranges 9 1 ton to 1000 ton Accuracy ± 0.25 % best fit straight line 2 Non-repeatability ± 0.02 % full scale Output (tolerance) 2 mv/v (nominal) Operation Compression Resolution Infinite Environmental Temperature, operating -57 C to 121 C [-70 F to 250 F] Temperature, compensated 21 C to 71 C [70 F to 160 F] Temperature, storage -73 C to 149 C [-100 F to 300 F] Temperature effect, zero % full scale/ F Temperature effect, span % full scale/ F Strain gage type Bonded foil Excitation (calibration) 10 Vdc Insulation resistance 5, Vdc Bridge resistance (tolerance) 350 ohm (nominal) Zero balance (tolerance) ± 1% of full scale Shunt calibration data Included termination (std) 1 ton to 5 ton Cable 10 ton to 1000 ton Connector Mechanical Maximum allowable load 150 % FS 3 Material All welded stainless steel Life cycles (approx.) 1 million cycles 50 ton 100 ton 250 ton 500 ton 1000 ton Wiring codes Cable exit 1 ton to 5 ton, unamplified Connector exit 10 ton to 1000 ton, unamplified Red (+) excitation A (+) excitation Black (-) excitation B (+) excitation Green (-) output C (-) excitation White (+) output D (-) excitation E (-) output F (+) output Specifications subject to change. Questions? Contact us at either , 227

86 Option codes Internal amplifiers Load ranges Temperature compensation Internal amplifiers 6, 7 termination connector orientation Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see honeywell.com/tmsensor-ship for updated listings. 1, 2.5, 5, 10, 25, 50, 100, 250, 500, 1000 ton 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 1d. -20 F to 130 F 1e. -20 F to 200 F 1f. 70 F to 250 F 2a. Four-wire, 0 Vdc to 5 Vdc output 2c. 0 Vdc to 5 Vdc 2j. 4 ma to 20 ma (three-wire) output 2k. 4 ma to 20 ma (two-wire) 11 6a. Bendix PTIH-10-6P (or equivalent), 6-pin (max. 250 F) 6b. MS3102E-14S-6P connector (10 ton to 1000 ton range) 5 6e. Integral cable: Teflon (1 ton to 5 ton range) 6f. Integral cable: PVC (-20 F to 160 F) 15a. Horizontal electrical exit port orientation 15b. Vertical electrical exit port orientation 15c. Radial electrical exit port orientation Shunt calibration 8a. Precision internal resistor (max. 250 F) 10 Bridge type 11a. Square bridge 10 11b. Symmetrical bridge 10 11c. Square and symmetrical bridge 10 31a. Dual bridge Bridge resistance Special calibration Shock and vibration 12b ohm (foil) (max. 250 F) 30a. Positive in compression, compression testing only 9a. 10 point (5 up/5 down) 20 % 70 F 9b. 20 point (10 up/10 down) 10 % 70 F 9c. ASTM E-74 calibration 9e. CE mark 30c. Negative in compression, compression testing only 44a. Shock and vibration resistance 1g. 70 F to 325 F 10 1h. 70 F to 400 F 10 1i. -65 F to 250 F 10 1j. 0 C to 50 C 1k. -20 C to 85 C 1m. -25 C to 110 C 2n (2N) 4 ma to 20 ma (two-wire) intrinsically safe 11 2t. 0 Vdc to 10 Vdc output 2u. Unamplified, mv/v output 6g. Integral cable: Neoprene (0 F to 180 F) 6 6i. Integral underwater cable (max. 180 F) 6 6j. 1/2-14 conduit fitting 6q. Integral cable: Polyurethane 6v. Phoenix connector on end of cable Amplifier specifications Output signal Input power (voltage) Input power (current) Freq. resp (amp) Power supply rej. Operating temp. Reverse voltage protection Short cir. protection Wiring code: connector (std) Wiring code: cable 4,5,6 Voltage output: Option 2a Voltage output: Option 2b Vehicle voltage output: Option 2c 0 V to 5 V ±5 V 0 V to 5 V or ±5 45 ma ±15 V or 26 Vdc to 32 Vdc ±15 V or 26 Vdc to 32 Vdc 18 Vdc to 28 Vdc Vehicle voltage output: Option 2t 0 V to 10 V or ±10 45 ma 15 Vdc to 28 Vdc Current three-wire: Option 2j 4 ma to 20 ma 22 Vdc to 32 Vdc Current two-wire: Option 2k 4 ma to 20 ma 9 Vdc to 32 Vdc 45 ma 45 ma 40 ma 40 ma 65 ma 4 ma to 28 ma Intrinsically safe amp: Option 2n (2N)*** 4 ma to 20 ma 9 Vdc to 28 Vdc 4 ma to 24 ma 3000 Hz 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz 60 db 60 db 60 db 60 db 60 db 60 db 60 db -20 F to 185 F -20 F to 185 F -20 F to 185 F -20 F to 185 F 0 F to 185 F 0 F to 185 F Yes Yes Yes Yes Yes Yes Yes Momentary Momentary Momentary Momentary Yes Yes Yes B (-)Output/supply C (-)Supply E Shunt cal 1 F Shunt cal 2 Br (-) Supply O (-)O utput/ supply G (+) Output B Shunt cal 1 Y Shunt cal 2 B (-)Output/supply C (-)Supply E Shunt cal 1 F Shunt cal 2 Br (-) Supply O (-)O utput/ supply G (+) Output B Shunt cal 1 Y Shunt cal 2 B Output common** C Supply return ** E Shunt cal 1 F Shunt cal 2 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 B (-) output C Supply return E Shunt cal 1 F Shunt cal 2 Bl Supply return G (+) Output W (+) Output B Shunt cal 1 Br Shunt cal 2 B Output common** C Supply return** E Shunt cal 1 F Shunt cal 2 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 B No connection C No connection E Case ground F No connection Bl (+) Output W Case ground -20 F to 185 F B No connection C No connection E Case ground F No connection Bl (+) Output W Case ground Interfaces 53e. Signature calibration 5 53t. TEDS IEEE module 8 * Black and green wires are internally connected. ** Pins B and C are internally connected. *** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. # Typical system diagram Mounting dimensions and characteristics Capacity (tons) (v.s.) D0 mm D1 mm D2 mm L1 mm L2 mm L3 mm H mm Thread lifting eye Optional bottom thread 1 6,6 [0.26] 22,1 [0.87] 9,4 [0.37] 19,05 [0.75] 0,51 [0.02] 1,52 [0.06] 9,53 [0.375] NA 8-32 UNC x 0.18 in deep 2.5 6,6 [0.26] 22,1 [0.87] 9,4 [0.37] 19,05 [0.75] 0,51 [0.02] 1,52 [0.06] 9,53 [0.375] NA 8-32 UNC x 0.18 in deep 5 10,41 [0.41] 24,89 [0.98] 13,46 [0.53] 22,35 [0.88] 1,02 [0.04] 1,52 [0.06] 9,53 [0.375] NA 8-32 UNC x 0.18 in deep 10 19,05 [0.75] 37,85 [1.49] 19,05 [0.75] 28,45 [1.12] 1,52 [0.06] 4,06 [0.16] 9,53 [0.375] NA 1/4-28 UNF x 0.25 in deep 25 29,97 [1.18] 49,78 [1.96] 29,97 [1.18] 44,96 [1.77] 3,05 [0.12] 7,62 [0.30] 19,05 [0.75] NA 1/4-28 UNF x 0.25 in deep 50 40,39 [1.59] 61,98 [2.44] 40,39 [1.59] 64,0 [2.52] 4,57 [0.18] 4,83 [0.19] 38,1 [1.5] NA 3/8-24 UNF x 0.38 in deep ,15 [2.25] 81,03 [3.19] 57,15 [2.25] 85,85 [3.38] 6,35 [0.25] 17,53 [0.69] 38,1 [1.5] NA 3/8-24 UNF x 0.38 in deep ,68 [3.57] 112,78 [4.44] 90,68 [3.57] 135,89 [5.35] 6,35 [0.25] 43,18 [1.7] 38,1 [1.5] 1/4-28 3/4-16 UNF x 0.75 in deep ,27 [5.05] 163,58 [6.44] 128,27 [5.05] 192,28 [7.57] 6,35 [0.25] 66,04 [2.6] 38,1 [1.5] 1/4-28 3/4-16 UNF x 0.75 in deep ,36 [7.14] 214,38 [8.44] 181,36 [7.14] 264,41 [10.41] 6,35 [0.25] 101,6 [4.0] 38,1 [1.5] 3/ UNF x 1.0 in deep Special requirements (consult factory) Have a special requirement? New diameter cable, different cable lengths, radiation proof, output option, temperature settings, TEDS IEEE modules, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. 228 Questions? Contact us at either , Specifications subject to change.

87 Model D Thru-Hole Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: BL913 BR P 1b Order code code Thru hole dia. Option code Order codes Various Model D thru-hole load cell 150 g to lb Thru-hole design Flexible design AL AN AP AR AT AV BL BN BR CN 150 g 250 g 500 g 1000 g 5 lb 10 lb 25 lb 50 lb 100 lb 250 lb CR CV DL DN DR DT DV EJ EL EN 500 lb 1000 lb 2000 lb 3000 lb 5000 lb 7500 lb lb lb lb lb Notes 1. Allowable maximum loads maximum load to be applied without damage. 2 Loads described allow for 100 % full scale axial loading with the bending loads specified. Torque loading maximum is without axial or other load. For any other combination consult factory. 2. Without damage loading to this level will not cause excessive zero shift of performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 3. Only for ranges greater than or equal to 5 lb. 4. Varies by features selected, consult factory. 5. Be sure to specify electrical termination option 6a or 6v in option code. For custom connector, consult factory. 6. Dimension H1 may increase with this option, consult factory. Not available with option 1c, 1e, 1f, 1g, 1h, or 1i. 7. Only available with integral cable units. 8. This unit calibrated to Imperial (non-metric) units. Specifications Performance Load ranges g to lb Accuracy 1 % Linearity (max.) ±0.5 % full scale Hysteresis (max.) ±0.5 % full scale Non-repeatability (max.) ±0.1 % full scale Output (tolerance) 150 g to 1000 g 20 mv/v (nominal) 5 lb to lb 2 mv/v (nominal) Operation Compression Resolution Infinite Environmental Temperature, operating -54 C to 121 C [-65 F to 250 F] Temperature, compensated 15 C to 71 C [60 F to 160 F] Temperature effect, zero 150 g to 1000 g 0.01 % full scale/ F 5 lb to lb % full scale/ F Temperature effect, span 150 g to 1000 g 0.02 % full scale/ F 5 lb to lb % full scale/ F Strain gage type 150 g to 1000 g Semiconductor 5 lb to lb Bonded foil Excitation (calibration) 150 g to 1000 g 5 Vdc 5 lb to lb 10 Vdc Insulation resistance Vdc Bridge resistance (tolerance) 150 g to 1000 g 500 ohm (nominal) 5 lb to lb 350 ohm (nominal) Zero balance (tolerance) ±1 % of full scale Shunt calibration data Included termination (std) Teflon cable (5 ft) Mechanical Maximum allowable load 150 % FS 1 Weight note 4 Material Stainless steel Life cycles (approx.) > 10 cycles fully reversed Deflection full scale note 4 Natural frequency note 4 Specifications subject to change. Questions? Contact us at either , 229

88 Option codes Wiring codes Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see honeywell.com/tmsensor-ship for updated listings. Load ranges 150 g, 250 g, 500 g, 1000 g; 5, 10, 25, 50, 100, 250, 500, 1000, 2000, 3000, 5000, 7500, 10000, 15000, 20000, lb Temperature compensation Internal amplifiers termination connector orientation Load direction Shock and vibration Interfaces 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 1d. -20 F to 130 F 1e. -20 F to 200 F 2u. Unamplified, mv/v output 1f. 70 F to 250 F 1g. 70 F to 325 F 3 1h. 70 F to 400 F 3 1i. -65 F to 250 F 6e. Integral cable: Teflon (5 ft) 6a. Bendix PTIH-10-6P (or equivalent), 6-pin (max. 250 F) on end of cable 6v. Phoenix connector on end of cable 6i. Integral underwater cable 6 15d. Connector on end of cable 5 30a. Positive in compression, compression testing only 30c. Negative in compression, compression testing only 44a. Shock and vibration resistance 53s. Signature calibration 5 (Inline) 53t. TEDS IEEE module 7 (Inline) Mounting dimensions and characteristics s 150, 250, 500, 1000 g Order code ØOD mm BL912 12,7 [0.50] 5, 10 lb BL912 25,4 [1.00] 25, 50, 100 lb BL912 25,4 [1.00] Frame A (100 to 2000 lb) Frame B (250 to lb) Frame C (2000 to lb) BL913 38,1 [1.50] BL914 50,8 [2.00] BL915 76,2 [3.00] ØID mm 2,54 [0.10] 5,08 [0.20] 5,08 [0.20] See below See below See below H1 mm 3,81 [0.15] 7,11 [0.28] 7,11 [0.28] 12,7 [0.50] 16,00 [0.63] 25,4 [1.0] H2 mm 0,51 [0.02] 0,76 [0.03] 0,76 [0.03] 1,27 [0.05] 1,52 [0.06] 2,03 [0.08] H3 mm 0,25 [0.01] 0,51 [0.02] 0,51 [0.02] 0,76 [0.03] 0,76 [0.03] 0,76 [0.03] ØD1 mm 5,08 [0.20] 6,60 [0.26] 9,14 [0.36] 12,7 [0.50] 22,53 [0.88] 43,18 [1.70] ØD2 mm 11,43 [0.45] 21,59 [0.85] 21,59 [0.85] 30,73 [1.21] 42,67 [1.68] 62,48 [2.46] Listed above are four different order codes; BL912, BL913, BL914, BL915. The frame size selection guide below indicates that with a single shell size (outside diameter), different thru holes are available for order codes BL913, BL914 and BL915 (frames A, B, and C, respectively). To choose a product, first select the desired load capacity. Then, if applicable, choose the desired inner diameter and an appropriate frame size. For example, a 250 lb load cell is available in the small frame size (A) with a nominal thru hole size of 1/8 in (P), 3/16 in (Q), 1/4 in (R) or 3/8 in (S) diameter, or in the medium frame size (B) with thru hole sizes up to 5/8 in (V). We manufacture the actual hole dimensions to provide some clearance; for example the 1/8 in (P) dimension, the actual dimension is in. Cable Red Black Green White Unamplified (+) excitation (-) excitation (-) output (+) output Typical system diagram Hole letters ØID (nom) P Q R S T V W Y Z 1/8 in 3/16 in 1/4 in 3/8 in 1/2 in 5/8 in 3/4 in 1 in 1 1/4 in ØID (act) in in in in in in in in in 100 lb A A A A NA NA NA NA NA 250 lb A or B A or B A or B A or B B B NA NA NA 500 lb A or B A or B A or B A or B B B NA NA NA 1000 lb A or B A or B A or B B B B NA NA NA 2000 lb A, B, or C A, B, or C A, B, or C B or C B or C B or C C C C 3000 lb B or C B or C B or C B or C B or C C C C C 5000 lb B or C B or C B or C B or C B or C C C C C 7500 lb B or C B or C B or C B or C B or C C C C C lb B or C B or C B or C B or C B or C C C C C lb C C C C C C C C C lb C C C C C C C C C lb C C C C C C C C C Special requirements (consult factory) Have a special requirement? New diameter cable, different cable lengths, radiation proof, output option, temperature settings, TEDS IEEE modules, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all 230 Questions? Contact us at either , Specifications subject to change.

89 Model TH Thru-Hole Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: BL911 EJ 1b Order code code Option code Order codes BL911 Model TH thru-hole load cell lb to lb range Thru-hole design Compact column construction mv/v output 0.25 % linearity EJ EL EN EP ER ET FJ FL lb lb lb lb lb lb lb lb Notes 1. Allowable maximum loads maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long-term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 3. This unit calibrated to Imperial (non-metric) units. 4. Cannot be used with options 1c, 1e, 1f, 1g, 1h, or 1i. Specifications Performance Load ranges lb to lb Accuracy 0.5 % Linearity (max.) ±0.25 % full scale Hysteresis (max.) ±0.25 % full scale Non-repeatability (max.) ± 0.1 % full scale Output (tolerance) 2 mv/v (nominal) Operation Compression Resolution Infinite Environmental Temperature, operating -54 C to 121 C [-65 F to 250 F] Temperature, compensated 15 C to 71 C [60 F to 160 F] Temperature effect, zero % full scale/ F Temperature effect, span % full scale/ F Strain gage type Bonded foil Excitation (calibration) 10 Vdc Insulation resistance 5, Vdc Bridge resistance 350 ohm Zero balance ±1 % full scale termination (std) Teflon cable (5 ft) Mechanical Maximum allowable load 150 % FS 1 Weight Case material Stainless steel Deflection full scale Natural frequency Specifications subject to change. Questions? Contact us at either , 231

90 Option codes Load ranges Temperature compensation Internal amplifiers termination Shunt calibration Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see honeywell.com/tmsensor-ship for updated listings. 15K, 20K, 30K, 50K, 75K, 100K, 150K, 200K 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 1d. -20 F to 130 F 1e. -20 F to 200 F 1f. 70 F to 250 F 2u. Unamplified, mv/v output 6a. Bendix PTIH-10-6P (or equivalent), 6-pin (max. 250 F) 6b. MS connector MS3102E-14S-6P (mates with MS3106E-14S-6S) (max. 160 F) 4 6e. Integral cable: Teflon (5 ft range) 6f. Integral cable: PVC 6g. Integral cable: Neoprene 8a. Precision internal resistor Special calibration 9a. 10 point (5 up/5 down) 20 % 70 F 9b. 20 point (10 up/10 down) 10 % 70 F 9c. ASTM E-74 calibration 30a. Positive in compression, compression testing only 30c. Negative in compression, compression testing only Bridge type Bridge resistance connector orientation Shock and vibration Interfaces 31a. Dual bridge 12b ohm (foil) 15a. Horizontal electrical exit port orientation 15b. Vertical electrical exit port orientation 15c. Radial electrical exit port orientation 15d. Connector on end of cable 44a. Shock and vibration resistance 53e. Signature calibration 53t. TEDS IEEE module 1g. 70 F to 325 F 1h. 70 F to 400 F 1i. -65 F to 250 F 1j. 0 C to 50 C 1k. -20 C to 85 C 1m. -25 C to 110 C 6h. Integral cable: Silicone 6i. Integral underwater cable 6j. 1/2-14 conduit fitting with 5 ft of 4 conductor PVC cable 6q. Integral cable: Polyurethane 6v. Phoenix connector on end of cable 15d. Connector on end of cable Wiring codes Cable Red Black Green White Unamplified (+) excitation (-) excitation (-) output (+) output Deflections and ringing frequencies Capacity (lb) Deflection at full scale mm Typical system diagram Ringing frequency (khz) Weight kg [lb] ,025 [0.001] 35 0,18 [0.4] ,025 [0.001] 35 0,18 [0.4] ,051 [0.002] 17 0,45 [1.0] ,051 [0.002] 17 0,45 [1.0] ,076 [0.003] 14 0,90 [2.0] ,076 [0.003] 14 0,90 [2.0] ,152 [0.006] 12 1,13 [2.5] ,102 [0.004] 10 2,72 [6] Mounting dimensions and characteristics (lb) H mm OD mm ID mm D2 mm D3 mm 15000, ,1 [1.50] 38,1 [1.50] 19,3 [0.76] 26,92 [1.06] 29,21 [1.15] 30000, ,8 [ [2.00] 50,8 [ [2.00] 25,65 [1.01] 38,1 [1.50] 38,1 [1.50] 75000, ,5 [2.50] 63,5 [2.50] 32,60 [1.26] 47,75 [1.88] 47,75 [1.88] ,2 [3.00] 76,2 [3.00] 38,35 [1.51] 58,67 [2.31] 61,97 [2.44] ,9 [3.50] 88,9 [3.50] 44,70 [1.76] 69,85 [2.75] 88,9 [3.50] Special requirements (consult factory) Have a special requirement? New diameter cable, different cable lengths, radiation proof, output option, temperature settings, TEDS IEEE modules, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. 232 Questions? Contact us at either , Specifications subject to change.

91 Model 3632 Compression Donut Load Cell Measures press fit loads on bearings Fits in limited or tight spaces Measure rolling mill loads Measure tie rod loads Notes 1. This unit calibrated to Imperial (non-metric) units. How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code and the desired load range in lbs. For example: K Order code Order codes (lb) 3632 Model 3632 tension/compression donut load cell Specifications Performance Load range , 50000, lb Non-linearity ±0.15 % of rated output Hysteresis ±0.15 % of rated output Repeatability ±0.15 % of rated output rated capacity 2 mv/v (nominal) Operation Compression Resolution Infinite Standard calibration Tension (+) and compression (-) Environmental Temperature, operating -54 C to 93 C [-65 F to 200 F] Temperature, compensated 21 C to 77 C [70 F to 170 F] Temperature effect, zero ±0.002 % of rated output/ F Temperature effect, output ±0.002 % of reading/ F Strain gage type Foil Excitation (maximum) 20 Vdc or Vac RMS Insulation resistance > Vdc Bridge resistance, 25K lb, 50K lb 480 ohm Bridge resistance, 100K lb 240 ohm Number of bridges 1 Zero balance ±1.0 % termination PT02E-10-6P Mechanical Static overload capacity 150 % of nominal capacity Material Carbon steel Natural frequency below Mechanical characteristics Nominal load limit capacity F z Static extraneous load limits lb N Static overload capacity (% of nominal capacity) Shear F X or F Y (lb) Bending M X or M Y (lb-in) Torque M Z (lb-in) Deflection at nominal load limit (in) Ringing frequency (Hz) 25K 125K K 3K K 200K K 13K K 500K K 91K 27K Specifications subject to change. Questions? Contact us at either , 233

92 Output Input Serial Number SETUP LOAD CELLS Mounting dimensions and characteristics Wiring codes Model A cm B cm C cm D cm E cm F cm ,16 [4] 5,08 [2] 7,62 [3] 5,08 [2] 2,54 [1] 8,26 [3.25] G cm 0,15 [0.06] H cm 4,78 [1.88] Wire Red Black Green (+) excitation (-) excitation (+) output A DIA. White (-) output Typical system diagram B DIA. C RECEP. PT02E-10-6P In-Line Amplifiers (Used with unamplified units only) Amplifier Output Universal In-Line Amplifiers UV +/-5 VDC UV-10 +/-10 VDC UBP 0 +/-5 VDC U3W 4-20mA (3 wire) U2W 4-20mA (2 wire) DIN rail Mount In-Line Amplifiers DV /- 5 VDC (3 wire) DA mA (3 wire) DV10 0 +/- 10 VDC (3 wire) Customer Supplied Chart Recorder Alarm Panel Data Acquisition Computer PLC Power Supply Honeywell In-Line Amplifier D E F G H MODEL 3632 Display Units SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH PSD OR lb. L1 L2 L3 L4 VALUE CLEAR CHAN TARE UP DOWN ENTER EXIT For reference only Mating Connectors & Cables 023-LW LF Mating Connector XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal) XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal) XX* Mating connector & 6 conductor cable (for connection to instrument 7541) XX** Mating connector & 4 conductor cable (for connection to instrument 7541) * XX represents length in feet 100ft maximum ** XX represents length in feet 20ft maximum 234 Questions? Contact us at either , Specifications subject to change.

93 Model 3336 Tension/ Compression Donut Load Cell Measures press fit loads on bearings Fits in limited or tight spaces Measure rolling mill loads Measure tie rod loads Notes 1. This unit calibrated to Imperial (non-metric) units. How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code and the desired load range in lbs. For example: K Order code Order codes (lb) 3336 Model 3336 tension/compression donut load cell Specifications Performance Load range , 10000, lb Non-linearity ±0.25 % of rated output Hysteresis ±0.15 % of rated output Repeatability ±0.15 % of rated output rated capacity ±2 mv/v (nominal) Operation Tension/compression Resolution Infinite Standard calibration Tension (+) and compression (-) Environmental Temperature, operating -54 C to 93 C [-65 F to 200 F] Temperature, compensated 21 C to 77 C [70 F to 170 F] Temperature effect, zero ±0.002 % of rated output/ F Temperature effect, output ±0.002 % of reading/ F Strain gage type Foil Excitation (maximum) 20 Vdc or Vac RMS Insulation resistance > Vdc Bridge resistance (tolerance) 5K lb 350 ohm Bridge resistance (tol.) 10K, 20K lb 700 ohm Number of bridges 1 or 2 Zero balance ±1.0 % termination MS3102E-14S-5P Mechanical Static overload capacity 150 % of nominal capacity Material Carbon steel Natural frequency below Mechanical characteristics Nominal load limit capacity F z Static extraneous load limits lb N Static overload capacity (% of nominal capacity) Shear F X or F Y (lb) Bending M X or M Y (lb-in) Torque M Z (lb-in) Deflection at nominal load limit (in) Ringing frequency (Hz) 5K 20K K K 50K K K 100K K 14K Specifications subject to change. Questions? Contact us at either , 235

94 SETUP LOAD CELLS Mounting dimensions and characteristics Wiring codes Model A cm B cm C cm D cm E cm F cm ,86 [9] 12,70 [5] 8,26 [3.25] 1,91 [0.75] 12,40 [4.88] 17,78 [7] Wire Red Black Green White (+) excitation (-) excitation (+) output (-) output Typical system diagram In-Line Amplifiers (Used with unamplified units only) Amplifier Output Universal In-Line Amplifiers UV +/-5 VDC UV-10 +/-10 VDC UBP 0 +/-5 VDC U3W 4-20mA (3 wire) U2W 4-20mA (2 wire) DIN rail Mount In-Line Amplifiers DV /- 5 VDC (3 wire) DA mA (3 wire) DV10 0 +/- 10 VDC (3 wire) Customer Supplied Chart Recorder Alarm Panel Data Acquisition Computer PLC Power Supply Honeywell In-Line Amplifier Output Input Serial Number For reference only MODEL 3336 Display Units SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH PSD OR lb. L1 L2 L3 L4 VALUE CLEAR CHAN TARE UP DOWN ENTER EXIT Mating Connectors & Cables 064-LW13621 Mating connector XX* Mating connector and six conductor cable (unamplified unit with sense leads but not shunt cal) XX** Mating connector (MS - 5 pin) and four conductor cable (unamplified sensor without sense leads) XX** Mating connector ( MS 5 pin ) & 6 conductor cable for connection to XX** Mating connector ( MS 5 pin ) & 4 conductor cable for connection to 7541 * XX represents length in feet 100ft maximum ** XX represents length in feet 20ft maximum 236 Questions? Contact us at either , Specifications subject to change.

95 Model 3719 Bolt and Engine Mount Force Sensor Compact High output Standard models for bolts size no. 2 thru 2 in and up to 20 mm Sensor and washers - carpenter 440C stainless steel Sensitive to neither bolt nor nut applied torque Notes 1. This unit calibrated to Imperial (non-metric) units. How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code and the bolt size. For example: Order code Order codes Bolt size/1000 (ex: 250/1000 = 1/4 in bolt) 3719 Model 3719 bolt and engine mount force sensor Specifications Performance Load range lb to lb [17000 to N] Non-linearity ranges up to 25K lb (67K N) ±3.0 % of rated output ranges 30K lb and up (102K N) ±4.0 % of rated output Hysteresis ranges up to 25K lb (67K N) ±5.0 % of rated output ranges 30K lb and up (102K N) ±7.0 % of rated output Repeatability ±0.10 % of rated output rated capacity ±2 mv/v to 3.5 mv/v depending on size (nominal) Resolution Infinite Standard calibration Compression Environmental Temperature, operating -54 C to 93 C [-65 F to 200 F] Temperature, compensated 21 C to 77 C [70 F to 170 F] Temperature effect, zero ranges up to 12K lb ±0.01 % of full scale/ F ranges 18K lb and up ±0.007 % of full scale/ F Temperature effect, output ranges up to 12K lb ±0.02 % of reading/ F ranges 18K lb and up ± % of reading/ F Excitation (maximum) 10 Vdc or Vac RMS Insulation resistance, bridge case > Vdc Bridge resistance (tolerance) 350 ohm Number of bridges 1 Zero balance ±1.0 Mechanical Static overload capacity 150 % of rated capacity Specifications subject to change. Questions? Contact us at either , 237

96 Mounting dimensions and characteristics Typical system diagram Model Bolt size Capacity lb C in ØD in ØA in ØB in T in No No No No No / / / / / / / / / / / / / MM 6 mm 17000* 9,40* 6,0* 16,3* 10,7* 1,5* MM 7 mm 27000* 12,57* 7,1* 16,8* 12,2* 1,5* MM 8 mm 31000* 12,57* 8,3* 19,8* 14,5* 1,5* MM 9 mm 36000* 12,57* 9,0* 20,3* 15,2* 1,5* MM 10 mm 46000* 12,57* 10,1* 20,3* 16,2* 1,5* MM 12 mm 67000* 15,75* 12,0* 27,9 22,1* 1,5* MM 14 mm * 16,76* 14,0* 31,8* 25,9* 2,0* MM 15 mm * 16,76* 15,5* 32,5* 26,4* 2,0* MM 16 mm ,76* 16,1* 34,3* 29,2* 2,0* MM 18 mm ,94* 18,1* 36,8* 31,8* 2,0* MM 20 mm ,70* 20,1* 43,2* 36,8* 2,4* * Capacities in Newtons, * Dimensions in millimeters For reference only 238 Questions? Contact us at either , Specifications subject to change.

97 Model RM Rod End In-Line Tension Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: AL413 DJ 6g Order codes Various Order code code Option code Model RM rod end in-line tension load cell DJ 2000 lb EL lb DN 3000 lb EN lb 2000 lb to lb range Hermetically sealed 0 Vdc to 5 Vdc or 4 ma to 20 ma outputs 0.2 % linearity CE approved 10 DP DR DT DV EJ 4000 lb 5000 lb lb lb lb EP ER ET FJ FL lb lb lb lb lb Notes 1. Allowable maximum loads maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 3. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal provides 50 % (unamplified units), 75 % (4 ma to 20 ma threewire units) or 80 % (voltage amplified units) of full scale output for quick calibration. Shunt calibration comes standard with internal amplifier option 2a, 2b, 2c, 2t and 2j. 4. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown; W=White; G=Green. Color specifying cable and number or letter specifying connector. 5. No mating connector necessary for cable option. 6. Cannot use with options 1c, 1e, 1f, 1g, 1h, or 1i. 7. Only available with option 2b or 2c. 8. Not available with amplified option. 9. Consult factory for TEDS availability with amplified models. 10. Termination dependent; consult factory. 11. This unit calibrated to Imperial (non-metric) units ohm bridge required. Specifications Performance Load ranges lb to lb 1 Linearity 100 lb to 1000 lb ±0.2 % full scale 2000 lb to lb ±0.15 % full scale lb to lb ±0.2 % full scale Hysteresis 100 lb to 1000 lb ±0.2 % full scale 2000 lb to lb ±0.15 % full scale lb to lb ±0.2 % full scale Non-repeatability ± 0.05 % full scale Output (tolerance) 2 mv/v Operation Tension Resolution Infinite Environmental Temperature, operating -54 C to 121 C [-65 F to 250 F] Temperature, compensated 15 C to 71 C [60 F to 160 F] Temperature effect, zero % full scale/ F Temperature effect, span % full scale/ F Strain gage type Bonded foil Excitation (calibration) 10 Vdc Excitation (acceptable) Up to 15 Vdc or Vac Insulation resistance Vdc Bridge resistance (tolerance) 350 ohm Zero balance (tolerance) ±1% full scale Shunt calibration data Included termination (std) 2000 lb to lb PTIH-10-6P or equivalent (hermetic stainless) lb to lb MS3102E-14S-6P or equivalent Mating connector (not included) 2000 lb to lb PT06A-10-6S or equivalent (AA111) lb to lb MS3106A-14S-6S or equivalent (AA121) Mechanical Maximum allowable load 150 % FS 1 Weight Material Stainless steel Deflection full scale Natural frequency Specifications subject to change. Questions? Contact us at either , 239

98 Option codes Internal amplifiers Load ranges Temperature compensation Internal amplifiers Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see honeywell.com/tmsensor-ship for updated listings. 2K, 3K, 4K, 5K, 7.5K, 10K, 15K, 20K, 30K, 50K, 75K, 100K, 150K, 200K 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 1d. -20 F to 130 F 1e. -20 F to 200 F 1f. 70 F to 250 F 2u. Unamplified, mv/v output 2b. 4 wire, ±5 Vdc output 2c. 0 Vdc to 5 Vdc 2j. 4 ma to 20 ma (three-wire) output 1g. 70 F to 325 F 8 1h. 70 F to 400 F 8 1i. -65 F to 250 F 8 1j. 0 C to 50 C 1k. -20 C to 85 C 1m. -25 C to 110 C 2k. 4 ma to 20 ma (two-wire) 12 2n (2N) 4 ma to 20 ma (two-wire) intrinsically safe 12 2t. 0 Vdc to 10 Vdc output Amplifier specifications Output signal Input power (voltage) Input power (current) Voltage output: Option 2b Voltage output: Option 2c ±5 V 0 V to 5 V or ±5 45 ma ±15 V or 26 Vdc to 32 Vdc 18 Vdc to 28 Vdc Voltage output: Option 2t 0 V to 10 V or ±10 45 ma 15 Vdc to 28 Vdc Current three-wire: Option 2j Current two-wire: Option 2k Intrinsically safe amp: Option 2n (2N)*** 4 ma to 20 ma 4 ma to 20 ma 4 ma to 20 ma 22 Vdc to 32 Vdc 15 Vdc to 40 Vdc 9 Vdc to 28 Vdc 45 ma 40 ma 40 ma 65 ma 4 ma to 28 ma 4 ma to 24 ma Internal amp enhancements 3a. Input/output isolation 7 3d. Remote buffered shunt calibration Freq. resp (amp) 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz termination 6a. Bendix PTIH-10-6P (or equivalent) 6-pin, (max. 250 F) (ranges lb and below) 6b. MS connector MS3102E-14S-6P (mates with MS3106E-14S-6), (max. 160 F) (ranges above lb) 6 6e. Integral cable: Teflon 6f. Integral cable: PVC 6g. Integral cable: Neoprene 6h. Integral cable: Silicone 6i. Integral underwater cable 6j. 1/2-14 conduit fitting with 5 ft of 4 conductor PVC cable 6q. Integral cable: Polyurethane 6v. Phoenix connector on end of cable Power supply rej. Operating temp. Reverse voltage protection 60 db 60 db 60 db 60 db 60 db 60 db -20 F to 185 F -20 F to 185 F -20 F to 185 F 0 F to 185 F 0 F to 185 F -20 F to 185 F Yes Yes Yes Yes Yes Yes Shunt calibration 8a. Precision internal resistor 8 Bridge type 11a. Square bridge 8 11b. Symmetrical bridge 8 11c. Square and symmetrical bridge 8 31a. Dual bridge Bridge resistance 12b ohm (foil) (max. 250 F) Short cir. protection Wiring code: connector (std) 5 Momentary Momentary Momentary Yes Yes Yes B Output common C Supply return E Shunt cal 1 F Shunt cal 2 B Output common** C Supply return ** E Shunt cal 1 F Shunt cal 2 B Output common** C Supply return** E Shunt cal 1 F Shunt cal 2 B Output common** C Supply return** E Shunt cal 1 F Shunt cal 2 B No connection C No connection E Case ground F No connection B No connection C No connection E Case ground F No connection Zero and span adjustment connector orientation Shock and vibration 14a. No access to zero and span adjustment 15a. Horizontal electrical exit port orientation 15b. Vertical electrical exit port orientation 15c. Radial electrical exit port orientation 15d. Connector on end of cable 44a. Shock and vibration resistance Wiring code: cable 5,6,7 Bl Output common G Supply return W (+) Output B Shunt cal 1 Br Shunt cal 2 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 Bl (+) Output W Case ground * Black and green wires are internally connected. ** Pins B and C are internally connected. *** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. # Bl (+) Output W Case ground Interfaces 53e. Signature calibration 8 53t. TEDS IEEE module 9 Wiring codes Connector Unamplified (std.) Deflections and ringing frequencies Capacity (lb) Deflection at full scale mm Ringing frequency (Hz) Weight kg [lb] ,076 [0.003] ,45 [1.0] ,076 [0.003] ,45 [1.0] A B C D E F (+) excitation (+) excitation (-) excitation (-) excitation (-) output (+) output ,076 [0.003] ,45 [1.0] ,076 [0.003] ,45 [1.0] ,102 [0.004] ,68 [1.5] ,102 [0.004] ,68 [1.5] ,127 [0.005] ,68 [1.5] ,127 [0.005] ,68 [1.5] ,127 [0.005] ,90 [4.2] ,127 [0.005] ,90 [4.2] to ,152 [0.006] ,34 [16.5] to ,178 [0.007] ,01 [35.3] 240 Questions? Contact us at either , Specifications subject to change.

99 Mounting dimensions and characteristics Unamplified only Amplified only Typical system diagram Order code (Amp/Unamp) D mm L1 mm A mm B mm L2 mm E mm F mm AL413/AL613 38,1 [1.50] 66,4 [2.60] 19,05 [0.75] 20,82 [0.82] see below 49,53 [1.95] 38,1 [1.50] AL415/AL615 44,45 [1.75] 66,4 [2.60] 19,05 [0.75] 20,82 [0.82] see below 49,53 [1.95] 38,1 [1.50] AL417/AL617 63,5 [2.50] 77,47 [3.05] 19,05 [0.75] 20,82 [0.82] see below 49,53 [1.95] 38,1 [1.50] Thread sizes and option codes 13a 13b 13c 13d 13e (lb) 1/2-20 UNF 3/4-16 UNF 7/8-14 UNF 1-14 UNF 1 1/2-12 UNF 2000 to 5000 AL413 AL413 AL to AL415 AL415 AL415 AL AL415 AL415 AL to AL417 L2 mm 24,13 [0.95] 24,13 [0.95] 24,13 [0.95] 31,75 [1.25] 38,1 [1.50] Non-standard ranges - order code AL411 (lb) Thread type D mm L1 mm L2 mm to /2-12 UNF 88,9 [3.50] 101,6 [4.00] 76,2 [3.00] to /2-8 UNF 114,3 [4.50] 127 [5.00] 101,6 [4.00] Special requirements (consult factory) Have a special requirement? New diameter cable, different cable lengths, radiation proof, output option, temperature settings, TEDS IEEE modules, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. Specifications subject to change. Questions? Contact us at either , 241

100 Model RH Rod End In-Line Tension Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: AL419 DJ 6g Order codes Various Order code code Option codes Model RH rod end in-line tension load cell 2000 lb to lb range Hermetically sealed 0 Vdc to 5 Vdc or 4 ma to 20 ma outputs 0.2 % linearity Intrinsically safe available (2N option only) 10 CE approved 11 Notes 1. Allowable maximum loads maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 3. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal provides 50 % (unamplified units), 75 % (4 ma to 20 ma threewire units) or 80 % (voltage amplified units) of full scale output for quick calibration. Shunt calibration comes standard with internal amplifier option 2a, 2b, 2c, 2t and 2j. 4. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown; W=White; G=Green. Color specifying cable and number or letter specifying connector. 5. No mating connector necessary for cable option. 6. Cannot be used with options 1c, 1e, 1f, 1g, 1h, or 1i. 7. Only available with option 2b or 2c. 8. Not available with amplified option. 9. Consult factory for TEDS availability with amplified models. 10. dependent; consult factory. Termination dependent; consult factory. 11. Internal amp and termination dependent; consult factory. 12. This unit calibrated to Imperial (non-metric) units ohm bridge required. DJ DN DP DR DT DV EJ 2000 lb 3000 lb 4000 lb 5000 lb lb lb lb Specifications Performance Load ranges lb to lb Linearity 100 lb to 1000 lb ±0.2 % full scale 2000 lb to lb ±0.15 % full scale lb to lb ±0.2 % full scale Hysteresis 100 lb to 1000 lb ±0.2 % full scale 2000 lb to lb ±0.15 % full scale lb to lb ±0.2 % full scale Non-repeatability ± 0.05 % full scale Output 2 mv/v Operation Tension Resolution Infinite Environmental Temperature, operating -54 C to 121 C [-65 F to 250 F] Temperature, compensated 15 C to 71 C [60 F to 160 F] Temperature effect, zero % full scale/ F Temperature effect, span % full scale/ F Strain gage type Bonded foil Excitation (calibration) 10 Vdc Excitation (acceptable) Up to 15 Vdc or Vac Insulation resistance Vdc Bridge resistance (tolerance) 350 ohm Zero balance (tolerance) ±1% of full scale Shunt calibration data Included termination (std) 2000 lb to lb PTIH-10-6P or equivalent (hermetic stainless) lb to lb MS3102E-14S-6P or equivalent Mating connector (not included) 2000 lb to lb PT06A-10-6S or equivalent (AA111) lb to lb MS3106A-14S-6S or equivalent (AA121) Mechanical Maximum allowable load 150 % FS 1 Weight Material Stainless steel Deflection full scale Natural frequency EL EN EP ER ET FJ FL lb lb lb lb lb lb lb 242 Questions? Contact us at either , Specifications subject to change.

101 Option codes Internal amplifiers Load ranges Temperature compensation Internal amplifiers Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see honeywell.com/tmsensor-ship for updated listings. 2K, 3K, 4K, 5K, 7.5K, 10K, 15K, 20K, 30K, 50K, 75K, 100K, 150K, 200K 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 1d. -20 F to 130 F 1e. -20 F to 200 F 1f. 70 F to 250 F 2u. Unamplified, mv/v output 2b. 4 wire, ±5 Vdc output 2c. 0 Vdc to 5 Vdc 2j. 4 ma to 20 ma (three-wire) output 1g. 70 F to 325 F 8 1h. 70 F to 400 F 8 1i. -65 F to 250 F 8 1j. 0 C to 50 C 1k. -20 C to 85 C 1m. -25 C to 110 C 2k. 4 ma to 20 ma (two-wire) 13 2t. 0 Vdc to 10 Vdc output 2n (2N) 4 ma to 20 ma (two-wire) intrinsically safe 13 Amplifier specifications Output signal Input power (voltage) Input power (current) Voltage output: Option 2b Voltage output: Option 2c ±5 V 0 V to 5 V or ±5 45 ma ±15 V or 26 Vdc to 32 Vdc 11 Vdc to 28 Vdc Voltage output: Option 2t 0 V to 10 V or ±10 45 ma 15 Vdc to 28 Vdc Current three-wire: Option 2j 4 ma to 20 ma 22 Vdc to 32 Vdc Current two-wire: Option 2k 4 ma to 20 ma 15 Vdc to 40 Vdc 45 ma 40 ma 40 ma 65 ma 4 ma to 28 ma Intrinsically safe amp: Option 2n (2N)*** 4 ma to 20 ma 9 Vdc to 28 Vdc 4 ma to 24 ma Internal amp enhancements 3a. Input/output isolation 7 3d. Remote buffered shunt calibration Freq. resp (amp) 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz termination 6a. Bendix PTIH-10-6P (or equivalent) 6-pin, (max. 250 F) (ranges lb and below) 6b. MS connector MS3102E-14S-6P (mates with MS3106E-14S-6), (max. 160 F) 6 (ranges above lb) 6e. Integral cable: Teflon 6f. Integral cable: PVC Shunt calibration 8a. Precision internal resistor 8 Bridge type 11a. Square bridge 8 11b. Symmetrical bridge 8 11c. Square and symmetrical bridge 8 31a. Dual bridge Bridge resistance 12b ohm (foil) (max. 250 F) 6g. Integral cable: Neoprene 6h. Integral cable: Silicone 6i. Integral underwater cable 6j. 1/2-14 conduit fitting with 5 ft of 4 conductor PVC cable 6q. Molded integral cable: Polyurethane 6v. Phoenix connector on end of cable Power supply rej. Operating temp. Reverse voltage protection Short cir. protection Wiring code: connector (std) 4 60 db 60 db 60 db 60 db 60 db 60 db -20 F to 185 F -20 F to 185 F -20 F to 185 F 0 F to 185 F 0 F to 185 F -20 F to 185 F Yes Yes Yes Yes Yes Yes Momentary Momentary Momentary Yes Yes Yes B Output common C Supply return E Shunt cal 1 F Shunt cal 2 B Output common** C Supply return ** E Shunt cal 1 F Shunt cal 2 B Output common** C Supply return** E Shunt cal 1 F Shunt cal 2 B Output common** C Supply return** E Shunt cal 1 F Shunt cal 2 B No connection C No connection E Case ground F No connection B No connection C No connection E Case ground F No connection Zero and span adjustment connector orientation Shock and vibration 14a. No access to zero and span adjustment 15a. Horizontal electrical exit port orientation 15b. Vertical electrical exit port orientation 15c. Radial electrical exit port orientation 15d. Connector on end of cable 44a. Shock and vibration resistance Wiring code: cable 4,5,6 Bl Output common G Supply return W (+) Output B Shunt cal 1 Br Shunt cal 2 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 Bl (+) Output W Case ground * Black and green wires are internally connected. ** Pins B and C are internally connected. *** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. # Bl (+) Output W Case ground Interfaces 53e. Signature calibration 8 53t. TEDS IEEE module 9 Deflections and ringing frequencies Wiring codes Capacity (lb) Deflection at full scale mm Ringing frequency (Hz) Weight kg [lb] Connector A B C D E F Unamplified (std.) (+) excitation (+) excitation (-) excitation (-) excitation (-) output (+) output ,076 [0.003] ,49 [1.1] ,076 [0.003] ,49 [1.1] ,076 [0.003] ,49 [1.1] ,076 [0.003] ,49 [1.1] ,102 [0.004] ,81 [1.8] ,102 [0.004] ,81 [1.8] ,127 [0.005] ,81 [1.8] ,127 [0.005] ,81 [1.8] ,127 [0.005] ,99 [4.4] ,127 [0.005] ,99 [4.4] to ,152 [0.006] ,01 [35.3] to ,178 [0.007] ,00 [39.7] Specifications subject to change. Questions? Contact us at either , 243

102 Mounting dimensions and characteristics Typical system diagram Unamplified only Amplified only Order code (Amp/Unamp) D mm L1 mm A mm B mm L2 mm E mm F mm AL419/AL619 38,1 [1.50] 107,95 [4.25] 19,05 [0.75] 20,82 [0.82] see below 49,53 [1.95] 38,1 [1.50] AL420/AL620 44,45 [1.75] 127 [5.00] 19,05 [0.75] 20,82 [0.82] see below 49,53 [1.95] 38,1 [1.50] AL424/AL624 63,5 [2.50] 177,8 [7.00] 19,05 [0.75] 20,82 [0.82] see below 49,53 [1.95] 38,1 [1.50] Thread size and option codes 13a 13b 13c 13d 13e (lb) 1/2-20 UNF 3/4-16 UNF 7/8-14 UNF 1-14 UNF 1 1/2-12 UNF 2000 to 5000 AL419/AL619 AL419/AL to AL420/AL620 AL420/AL620 AL420/AL620 AL424/AL AL420/AL620 AL420/AL620 AL424/AL to AL424/AL624 L2 mm 19,05 [0.75] 24,13 [0.95] 24,13 [0.95] 25,4 [1.0] 38,1 [1.50] Non-standard ranges - order code AL425 (unamplified only) (lb) Thread type D mm L1 mm L2 mm to /2-12 UNF 114,3 [4.50] 342,9 [13.50] 88,9 [3.50] to /2-8 UNF 139,7 [5.50] 457,2 [18.00] 114,3 [4.50] Special requirements (consult factory) Have a special requirement? New diameter cable, different cable lengths, radiation proof, output option, temperature settings, TEDS IEEE modules, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. 244 Questions? Contact us at either , Specifications subject to change.

103 Model RF Rod End In-Line Tension Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: AL414 DJ 6g Order codes Various Order code code Option code Model RF rod end in-line tension load cell DL 2000 lb EL lb DN 3000 lb EN lb 2000 lb to lb range Hermetically sealed 0 Vdc to 5 Vdc or 4 ma to 20 ma outputs 0.2 % linearity CE approved 10 DP DR DT DV EJ 4000 lb 5000 lb 7500 lb lb lb EP ER ET FJ FL lb lb lb lb lb Notes 1. Allowable maximum loads maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 3. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal provides 50 % (unamplified units), 75 % (4 ma to 20 ma threewire units) or 80 % (voltage amplified units) of full scale output for quick calibration. Shunt calibration comes standard with internal amplifier option 2a, 2b, 2c, 2t and 2j. 4. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown; W=White; G=Green. Color specifying cable and number or letter specifying connector. 5. No mating connector necessary for cable option. 6. Cannot be used with options 1c, 1e, 1f, 1g, 1h, or 1i. 7. Only available with option 2b or 2c. 8. Not available with amplified option. 9. Consult factory for TEDS availability with amplified models. 10. Termination dependent; consult factory. 11. This unit calibrated to Imperial (non-metric) units ohm bridge required. Specifications Performance Load ranges lb to lb Linearity 100 lb to 1000 lb ±0.2 % full scale 2000 lb to lb ±0.15 % full scale lb to lb ±0.2 % full scale Hysteresis 100 lb to 1000 lb ±0.2 % full scale 2000 lb to lb ±0.15 % full scale lb to lb ±0.2 % full scale Non-repeatability ± 0.05 % full scale Output 2 mv/v Operation Tension Resolution Infinite Environmental Temperature, operating -54 C to 121 C [-65 F to 250 F] Temperature, compensated 15 C to 71 C [60 F to 160 F] Temperature effect, zero % full scale/ F Temperature effect, span % full scale/ F Strain gage type Bonded foil Excitation (calibration) 10 Vdc Excitation (acceptable) Up to 15 Vdc or Vac Insulation resistance Vdc Bridge resistance (tolerance) 350 ohm Zero balance (tolerance) ±1% of full scale Shunt calibration data Included termination (std) 2000 lb to lb PTIH-10-6P or equivalent (hermetic stainless) lb to lb MS3102E-14S-6P or equivalent Mating connector (not included) 2000 lb to lb PT06A-10-6S or equivalent (AA111) lb to lb MS3106A-14S-6S or equivalent (AA121) Mechanical Maximum allowable load 150 % FS 1 Weight Material Stainless steel Deflection full scale Natural frequency Specifications subject to change. Questions? Contact us at either , 245

104 Option codes Load ranges Temperature compensation Internal amplifiers Internal amp enhancements termination Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see for updated listings. 2K, 3K, 4K, 5K, 7.5K, 10K, 15K, 20K, 30K, 50K, 75K, 100K, 150K, 200K 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 1d. -20 F to 130 F 1e. -20 F to 200 F 1f. 70 F to 250 F 2b. 4 wire, ±5 Vdc output 2c. 0 Vdc to 5 Vdc 2j. 4 ma to 20 ma (three-wire) output 2k. 4 ma to 20 ma (two-wire) 12 3a. Input/output isolation 7 3d. Remote buffered shunt calibration 6a. Bendix PTIH-10-6P (or equivalent) 6-pin, (max. 250 F) (ranges and below) 6b. MS connector MS3102E-14S-6P (mates with MS3106E-14S-6), (max. 160 F) (ranges above lb) 6 6e. Integral cable: Teflon 6f. Integral cable: PVC Shunt calibration 8a. Precision internal resistor 8 Bridge type 11a. Square bridge 8 11b. Symmetrical bridge 8 11c. Square and symmetrical bridge 8 31a. Dual bridge 8 Bridge resistance Zero and span adjustment connector orientation 12b ohm (foil) (max. 250 F) 14a. No access to zero and span adjustment 15a. Horizontal electrical exit port orientation 15b. Vertical electrical exit port orientation 15c. Radial electrical exit port orientation 15d. Connector on end of cable 1g. 70 F to 325 F 6 1h. 70 F to 400 F 6 1i. -65 F to 250 F 6 1j. 0 C to 50 C 1k. -20 C to 85 C 1m. -25 C to 110 C 2n (2N) 4 ma to 20 ma (two-wire) intrinsically safe 12 2t. 0 Vdc to 10 Vdc output 2u. Unamplified, mv/v output 6g. Integral cable: Neoprene 6h. Integral cable: Silicone 6i. Integral underwater cable 6j. 1/2-14 conduit fitting with 5 ft of 4 conductor PVC cable 6q. Molded integral cable: Polyurethane 6v. Phoenix connector on end of cable Internal amplifiers Amplifier specifications Output signal Input power (voltage) Input power (current) Freq. resp (amp) Power supply rej. Operating temp. Reverse voltage protection Short cir. protection Wiring code: connector (std) 4 Wiring code: cable 4,5,6 Voltage output: Option 2b Voltage output: Option 2c ±5 V 0 V to 5 V or ±5 45 ma ±15 V or 26 Vdc to 32 Vdc 11 Vdc to 28 Vdc Voltage output: Option 2t 0 V to 10 V or ±10 45 ma 15 Vdc to 28 Vdc Current three-wire: Option 2j Current two-wire: Option 2k Intrinsically safe amp: Option 2n (2N)*** 4 ma to 20 ma 4 ma to 20 ma 4 ma to 20 ma 22 Vdc to 32 Vdc 15 Vdc to 40 Vdc 9 Vdc to 28 Vdc 45 ma 40 ma 40 ma 65 ma 4 ma to 28 ma 4 ma to 24 ma 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz 60 db 60 db 60 db 60 db 60 db 60 db -20 F to 185 F -20 F to 185 F -20 F to 185 F 0 F to 185 F 0 F to 185 F -20 F to 185 F Yes Yes Yes Yes Yes Yes Momentary Momentary Momentary Yes Yes Yes B Output common C Supply return E Shunt cal 1 F Shunt cal 2 Bl Output common G Supply return W (+) Output B Shunt cal 1 Br Shunt cal 2 B Output common** C Supply return ** E Shunt cal 1 F Shunt cal 2 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 B Output common** C Supply return** E Shunt cal 1 F Shunt cal 2 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 B Output common** C Supply return** E Shunt cal 1 F Shunt cal 2 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 B No connection C No connection E Case ground F No connection Bl (+) Output W Case ground * Black and green wires are internally connected. ** Pins B and C are internally connected. *** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. # B No connection C No connection E Case ground F No connection Bl (+) Output W Case ground Shock and vibration 44a. Shock and vibration resistance Interfaces 53e. Signature calibration 8 53t. TEDS IEEE module 9 Deflections and ringing frequencies Capacity (lb) Deflection at full scale mm Ringing frequency (Hz) Weight kg [lb] Wiring codes Connector Unamplified (std.) A (+) excitation B (+) excitation C (-) excitation D (-) excitation E (-) output F (+) output ,076 [0.003] ,58 [1.3] ,076 [0.003] ,58 [1.3] ,076 [0.003] ,58 [1.3] ,076 [0.003] ,58 [1.3] ,076 [0.003] ,72 [1.6] ,076 [0.003] ,72 [1.6] ,076 [0.003] ,72 [1.6] ,102 [0.004] ,77 [1.7] ,102 [0.004] ,58 [3.5] ,127 [0.005] ,67 [3.7] to ,152 [0.006] ,00 [39.7] to ,178 [0.007] ,02 [72.8] 246 Questions? Contact us at either , Specifications subject to change.

105 Mounting dimensions and characteristics Typical system diagram Unamplified only Amplified only Order code (Amp/Unamp) D mm L1 mm A mm B mm L2 mm E mm F mm AL414/AL614 38,1 [1.50] 107,95 [4.25] 19,05 [0.75] 20,82 [0.82] see below 49,53 [1.95] 38,1 [1.50] AL416/AL616 44,45 [1.75] 127 [5.00] 19,05 [0.75] 20,82 [0.82] see below 49,53 [1.95] 38,1 [1.50] AL418/AL618 63,5 [2.50] 177,8 [7.00] 19,05 [0.75] 20,82 [0.82] see below 49,53 [1.95] 38,1 [1.50] Thread sizes and option codes 13a 13b 13c 13d 13e (lb) 1/2-20 UNF 3/4-16 UNF 7/8-14 UNF 1-14 UNF 1 1/2-12 UNF 2000 to 5000 AL414 AL to AL416 AL416 AL416 AL AL416 AL416 AL to AL418 L2 mm 19,05 [0.75] 24,13 [0.95] 24,13 [0.95] 25,4 [1.0] 38,1 [1.50] Non-standard ranges - order code AL412 (lb) Thread type D mm L1 mm L2 mm to /2-12 UNF 114,3 [4.50] 342,9 [13.50] 88,9 [3.50] to /2-8 UNF 139,7 [5.50] 457,2 [18.00] 114,3 [4.50] Special requirements (consult factory) Have a special requirement? New diameter cable, different cable lengths, radiation proof, output option, temperature settings, TEDS IEEE modules, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. Specifications subject to change. Questions? Contact us at either , 247

106 Model RGM Rod End In-Line Compression/ Tension Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: AL426 DJ 6g Order codes AL426 AL626 Order code code Option code Model RGM rod end in-line compression/tension load cell (unamplified) Model RGM rod end in-line compression/tension load cell (amplified) 2000 lb to lb range Hermetically sealed 0 Vdc to 5 Vdc or 4 ma to 20 ma outputs Compression/tension 0.25 % accuracy CE approved 11 Notes 1. Allowable maximum loads maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 3. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal provides 50 % (unamplified units), 75 % (4 ma to 20 ma threewire units) or 80 % (voltage amplified units) of full scale output for quick calibration. Shunt calibration comes standard with internal amplifier option 2a, 2b, 2c, 2t and 2j. 4. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown; W=White; G=Green. Color specifying cable and number or letter specifying connector. 5. No mating connector necessary for cable option. 6. Cannot be used with options 1c, 1e, 1f, 1g, 1h, or 1i. 7. Only available with option 2b or 2c. 8. Not available with amplified option. 9. Consult factory for TEDS availability with amplified models. 10. Positive in compression, calibrated in compression only. 11. Termination dependent; consult factory. 12. This unit calibrated to Imperial (non-metric) units ohm bridge required. DJ DN DP DR DV EJ EM EP 2000 lb 3000 lb 4000 lb 5000 lb lb lb lb lb Specifications Performance Load ranges , 3000, 4000, 5000, 10000, 15000, 25000, lb Accuracy ±0.25 % full scale Linearity ±0.25 % full scale Hysteresis ±0.25 % full scale Non-repeatability ± 0.05 % full scale Output (tolerance) 1 mv/v (nominal) Operation Tension/compression 10 Resolution Infinite Environmental Temperature, operating -54 C to 121 C [-65 F to 250 F] Temperature, compensated 15 C to 71 C [60 F to 160 F] Temperature effect, zero % full scale/ F Temperature effect, span % full scale/ F Strain gage type Bonded foil Excitation (calibration) 10 Vdc Excitation (acceptable) Up to 15 Vdc or Vac Insulation resistance Vdc Bridge resistance (tolerance) 700 ohm Zero balance (tolerance) ±3 % full scale Shunt calibration data Included termination (std) PTIH-10-6P or equivalent (hermetic stainless) Mechanical Maximum allowable load 150 % FS 1 Weight Material Stainless steel Life cycles (approx) >10 million cycles Deflection full scale Natural frequency 248 Questions? Contact us at either , Specifications subject to change.

107 Option codes Internal amplifiers Load ranges Temperature compensation Internal amplifiers Internal amp enhancements termination Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see honeywell.com/tmsensor-ship for updated listings. 2K, 3K, 4K, 5K, 10K, 15K, 25K, 50K 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 1d. -20 F to 130 F 1e. -20 F to 200 F 1f. 70 F to 250 F 2u. Unamplified, mv/v output 2b. 4 wire, ±5 Vdc output 2c. 0 Vdc to 5 Vdc 3a. Input/output isolation 7 3d. Remote buffered shunt calibration 6a. Bendix PTIH-10-6P (or equivalent) 6-pin, (max. 250 F) 6b. MS connector MS3102E-14S-6P (mates with MS3106E-14S-6), (max. 160 F) 6 6e. Integral cable: Teflon 6f. Integral cable: PVC 1g. 70 F to 325 F 8 1h. 70 F to 400 F 8 1i. -65 F to 250 F 8 1j. 0 C to 50 C 1k. -20 C to 85 C 1m. -25 C to 110 C 2j. 4 ma to 20 ma (three-wire) output 2k. 4 ma to 20 ma (two-wire) 13 2t. 0 Vdc to 10 Vdc output 6g. Integral cable: Neoprene 6h. Integral cable: Silicone 6i. Integral underwater cable 6j. 1/2-14 conduit fitting with 5 ft of 4 conductor PVC cable 6q. Molded integral cable: Polyurethane 6v. Phoenix connector on end of cable Amplifier specifications Output signal Input power (voltage) Input power (current) Freq. resp (amp) Power supply rej. Operating temp. Voltage output: Option 2b Voltage output: Option 2c ±5 V 0 V to 5 V or ±5 45 ma ±15 V or 26 Vdc to 32 Vdc 11 Vdc to 28 Vdc Voltage output: Option 2t 0 V to 10 V or ±10 45 ma 15 Vdc to 28 Vdc Current three-wire: Option 2j 4 ma to 20 ma 22 Vdc to 32 Vdc Current two-wire: Option 2k 4 ma to 20 ma 15 Vdc to 40 Vdc 45 ma 40 ma 40 ma 65 ma 4 ma to 28 ma Intrinsically safe amp: Option 2n (2N)*** 4 ma to 20 ma 9 Vdc to 28 Vdc 4 ma to 24 ma 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz 60 db 60 db 60 db 60 db 60 db 60 db -20 F to 185 F -20 F to 185 F -20 F to 185 F 0 F to 185 F 0 F to 185 F -20 F to 185 F Shunt calibration 8a. Precision internal resistor 8 Bridge type 11a. Square bridge 8 11b. Symmetrical bridge 8 11c. Square and symmetrical bridge 8 31a. Dual bridge Bridge resistance Zero and span adjustment connector orientation Shock and vibration 12b ohm (foil) (max. 250 F) 14a. No access to zero and span adjustment 15a. Horizontal electrical exit port orientation 15b. Vertical electrical exit port orientation 15c. Radial electrical exit port orientation 15d. Connector on end of cable 44a. Shock and vibration resistance Interfaces 53e. Signature calibration 8 53t. TEDS IEEE module 9 Reverse voltage protection Short cir. protection Wiring code: connector (std) 4 Wiring code: cable 4,5,6 Yes Yes Yes Yes Yes Yes Momentary Momentary Momentary Yes Yes Yes B Output common C Supply return E Shunt cal 1 F Shunt cal 2 Bl Output common G Supply return W (+) Output B Shunt cal 1 Br Shunt cal 2 B Output common** C Supply return ** E Shunt cal 1 F Shunt cal 2 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 B Output common** C Supply return** E Shunt cal 1 F Shunt cal 2 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 B Output common** C Supply return** E Shunt cal 1 F Shunt cal 2 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 B No connection C No connection E Case ground F No connection Bl (+) Output W Case ground * Black and green wires are internally connected. ** Pins B and C are internally connected. *** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. # B No connection C No connection E Case ground F No connection Bl (+) Output W Case ground Wiring codes Allowable maximum loads 2 Connector A Unamplified (std.) (+) excitation Capacity (lb) Side load (lb) (% of load capacity) Torque (lb-in) (% of load capacity) B C D E F (+) excitation (-) excitation (-) excitation (-) output (+) output % 20 % % 20 % % 20 % % 20 % % 20 % % 20 % % 20 % % 20 % Specifications subject to change. Questions? Contact us at either , 249

108 Mounting dimensions and characteristics Typical system diagram Unamplified only Amplified only (lb) D mm T L2 mm L1 mm A mm B mm E mm F mm 2000 to ,45 [1.75] 3/4-16 UNF 24,13 [0.95] 66,80 [2.63] 19,05 [0.75] 20,82 [0.82] 49,53 [1.95] 38,1 [1.50] to ,5 [2.50] 1 1/2-12 UNF 44,45 [1.75] 88,9 [3.50] 19,05 [0.75] 20,82 [0.82] 49,53 [1.95] 38,1 [1.50] to ,9 [3.50] 2-12 UNF 57,15 [2.25] 88,9 [3.50] 19,05 [0.75] 20,82 [0.82] 49,53 [1.95] 38,1 [1.50] Deflections and ringing frequencies Capacity (lb) Deflection at full scale mm Ringing frequency (Hz) Weight kg [lb] ,025 [0.001] ,55 [1.2] ,025 [0.001] ,55 [1.2] [0.0015] ,59 [1.3] ,050 [0.002] ,63 [1.4] ,050 [0.002] ,3 [2.9] ,050 [0.002] ,3 [2.9] ,050 [0.002] ,3 [9.5] ,076 [0.003] ,3 [9.5] Special requirements (consult factory) Have a special requirement? New diameter cable, different cable lengths, radiation proof, output option, temperature settings, TEDS IEEE modules, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. 250 Questions? Contact us at either , Specifications subject to change.

109 Model RGH Rod End In-Line Compression/ Tension Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: AL427 DJ 6g Order codes AL427 AL627 Order code code Option code Model RGH rod end in-line compression/tension load cell (unamplified) Model RGH rod end in-line compression/tension load cell (amplified) DJ DN DP 2000 lb 3000 lb 4000 lb 2000 lb to lb range Hermetically sealed 0 Vdc to 5 Vdc or 4 ma to 20 ma outputs Compression/tension 0.25 % accuracy CE approved 10 Notes 1. Allowable maximum loads maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 3. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal provides 50 % (unamplified units), 75 % (4 ma to 20 ma threewire units) or 80 % (voltage amplified units) of full scale output for quick calibration. Shunt calibration comes standard with internal amplifier option 2a, 2b, 2c, 2t and 2j. 4. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown; W=White; G=Green. Color specifying cable and number or letter specifying connector. 5. No mating connector necessary for cable option. 6. Cannot use with options 1c, 1e, 1f, 1g, 1h, or 1i. 7. Only available with option 2b or 2c. 8. Not available with amplified option. 9. Consult factory for TEDS availability with amplified models. 10. Termination dependent; consult factory. 11. This unit calibrated to Imperial (non-metric) units ohm bridge required. DR DV EJ EM EP 5000 lb lb lb lb lb Specifications Performance Load ranges , 3000, 4000, 5000, 10000, 25000, lb Accuracy ±0.25 % full scale 1 Linearity ±0.25 % full scale Hysteresis ±0.25 % full scale Non-repeatability ± 0.05 % full scale Output (tolerance) 1 mv/v (nominal) Operation Tension/compression Resolution Infinite Environmental Temperature, operating -54 C to 121 C [-65 F to 250 F] Temperature, compensated 15 C to 71 C [60 F to 160 F] Temperature effect, zero % full scale/ F Temperature effect, span % full scale/ F Strain gage type Bonded foil Excitation (calibration) 10 Vdc Excitation (acceptable) Up to 15 Vdc or Vac Insulation resistance Vdc Bridge resistance 700 ohm Shunt calibration data Included termination (std) PTIH-10-6P or equivalent (hermetic stainless) Mechanical Maximum allowable load 150 % FS 1 Case material Stainless steel Deflection full scale 0,076 mm [0.003 in] Life cycles (approx) >10 million cycles Specifications subject to change. Questions? Contact us at either , 251

110 Option codes Load ranges Temperature compensation Internal amplifiers Internal amp enhancements termination Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see honeywell.com/tmsensor-ship for updated listings. 2K, 3K, 4K, 5K, 10K, 15K, 25K, 50K lb 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 1d. -20 F to 130 F 1e. -20 F to 200 F 1f. 70 F to 250 F 2u. Unamplified, mv/v output 2b. 4 wire, ±5 Vdc output 2c. 0 Vdc to 5 Vdc 3a. Input/output isolation 7 3d. Remote buffered shunt calibration 6a. Bendix PTIH-10-6P (or equivalent) 6-pin, (max. 250 F) 6b. MS connector MS3102E-14S-6P (mates with MS3106E-14S-6), (max. 160 F) 6 6e. Integral cable: Teflon 6f. Integral cable: PVC Shunt calibration 8a. Precision internal resistor 8 Bridge type 11a. Square bridge 8 11b. Symmetrical bridge 8 11c. Square and symmetrical bridge 8 31a. Dual bridge Bridge resistance Zero and span adjustment connector orientation Shock and vibration 12b ohm (foil) (max. 250 F) 14a. No access to zero and span adjustment 15a. Horizontal electrical exit port orientation 15b. Vertical electrical exit port orientation 15c. Radial electrical exit port orientation 15d. Connector on end of cable 44a. Shock and vibration resistance Interfaces 53e. Signature calibration 8 53t. TEDS IEEE module 9 1g. 70 F to 325 F 8 1h. 70 F to 400 F 8 1i. -65 F to 250 F 8 1j. 0 C to 50 C 1k. -20 C to 85 C 1m. -25 C to 110 C 2j. 4 ma to 20 ma (three-wire) output 2k. 4 ma to 20 ma (two-wire) 12 2t. 0 Vdc to 10 Vdc output 6g. Integral cable: Neoprene 6h. Integral cable: Silicone 6i. Integral underwater cable 6j. 1/2-14 conduit fitting with 5 ft of 4 conductor PVC cable 6q. Molded integral cable: Polyurethane 6v. Phoenix connector on end of cable Internal amplifiers Amplifier specifications Output signal Input power (voltage) Input power (current) Freq. resp (amp) Power supply rej. Operating temp. Reverse voltage protection Short cir. protection Wiring code: connector (std) 4 Wiring code: cable 4,5,6 Voltage output: Option 2b Voltage output: Option 2c ±5 V 0 V to 5 V or ±5 45 ma ±15 V or 26 Vdc to 32 Vdc 11 Vdc to 28 Vdc Voltage output: Option 2t 0 V to 10 V or ±10 45 ma 15 Vdc to 28 Vdc Current three-wire: Option 2j Current two-wire: Option 2k Intrinsically safe amp: Option 2n (2N)*** 4 ma to 20 ma 4 ma to 20 ma 4 ma to 20 ma 22 Vdc to 32 Vdc 15 Vdc to 40 Vdc 9 Vdc to 28 Vdc 45 ma 40 ma 40 ma 65 ma 4 ma to 28 ma 4 ma to 24 ma 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz 60 db 60 db 60 db 60 db 60 db 60 db -20 F to 185 F -20 F to 185 F -20 F to 185 F 0 F to 185 F 0 F to 185 F -20 F to 185 F Yes Yes Yes Yes Yes Yes Momentary Momentary Momentary Yes Yes Yes B Output common C Supply return E Shunt cal 1 F Shunt cal 2 Bl Output common G Supply return W (+) Output B Shunt cal 1 Br Shunt cal 2 B Output common** C Supply return ** E Shunt cal 1 F Shunt cal 2 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 B Output common** C Supply return** E Shunt cal 1 F Shunt cal 2 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 B Output common** C Supply return** E Shunt cal 1 F Shunt cal 2 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 B No connection C No connection E Case ground F No connection Bl (+) Output W Case ground * Black and green wires are internally connected. ** Pins B and C are internally connected. *** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. # B No connection C No connection E Case ground F No connection Bl (+) Output W Case ground Wiring codes Allowable maximum loads 2 Connector A B C D E F Unamplified (std.) (+) excitation (+) excitation (-) excitation (-) excitation (-) output (+) output Capacity (lb) Side load (lb) (% of load capacity) % 20 % % 20 % % 20 % % 20 % % 20 % % 20 % % 20 % % 20 % Torque (lb-in) (% of load capacity) 252 Questions? Contact us at either , Specifications subject to change.

111 Mounting dimensions and characteristics Unamplified only Amplified only Typical system diagram (lb) D mm T L2 mm L1 mm A mm B mm E mm F mm 2000 to ,45 [1.75] 3/4-16 UNF 24,13 [0.95] 66,80 [2.63] 19,05 [0.75] 20,82 [0.82] 49,53 [1.95] 38,1 [1.50] to ,5 [2.50] 1 1/2-12 UNF 44,45 [1.75] 114,3 [4.50] 19,05 [0.75] 20,82 [0.82] 49,53 [1.95] 38,1 [1.50] to ,9 [3.50] 2-12 UNF 57,15 [2.25] 146,05 [5.75] 19,05 [0.75] 20,82 [0.82] 49,53 [1.95] 38,1 [1.50] Deflections and ringing frequencies Capacity (lb) Deflection at full scale mm Ringing frequency (khz) Weight kg [lb] ,025 [0.001] ,54 [1.2] ,025 [0.001] ,54 [1.2] ,038 [0.0015] ,59 [1.3] ,050 [0.002] ,63 [1.4] ,050 [0.002] ,31 [2.9] ,050 [0.002] ,31 [2.9] ,050 [0.002] ,30 [9.5] ,076 [0.003] ,49 [9.9] Special requirements (consult factory) Have a special requirement? New diameter cable, different cable lengths, radiation proof, output option, temperature settings, TEDS IEEE modules, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. Specifications subject to change. Questions? Contact us at either , 253

112 Model RGF Rod End In-Line Compression/ Tension Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: AL428 DV 6i Order codes AL428 AL628 Order code code Option code Model RGF rod end in-line compression/tension load cell (unamplified) Model RGF rod end in-line compression/tension load cell (amplified) 2000 lb to lb range Hermetically sealed 0 Vdc to 5 Vdc or 4 ma to 20 ma outputs Compression/tension 0.25 % accuracy CE approved 10 Notes 1. Allowable maximum loads maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 3. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal provides 50 % (unamplified units), 75 % (4 ma to 20 ma threewire units) or 80 % (voltage amplified units) of full scale output for quick calibration. Shunt calibration comes standard with internal amplifier option 2a, 2b, 2c, 2t and 2j. 4. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown; W=White; G=Green. Color specifying cable and number or letter specifying connector. 5. No mating connector necessary for cable option. 6. Cannot be used with options 1c, 1e, 1f, 1g, 1h, or 1i. 7. Only available with option 2b or 2c. 8. Not available with amplified option. 9. Consult factory for TEDS availability with amplified models. 10. Termination dependent; consult factory. 11. This unit calibrated to Imperial (non-metric) units ohm bridge required. DJ DN DR DV EJ EM EP 2000 lb 3000 lb 5000 lb lb lb lb lb Specifications Performance Load ranges , 3000, 5000, 10000, 15000, 25000, lb Accuracy ±0.25 % full scale 1 Linearity ±0.25 % full scale Hysteresis ±0.25 % full scale Non-repeatability ± 0.05 % full scale Output (tolerance) 1 mv/v (nominal) Operation Tension/compression Resolution Infinite Environmental Temperature, operating -54 C to 121 C [-65 F to 250 F] Temperature, compensated 15 C to 71 C [60 F to 160 F] Temperature effect, zero % full scale/ F Temperature effect, span % full scale/ F Strain gage type Bonded foil Excitation (calibration) 10 Vdc Excitation (acceptable) Up to 15 Vdc or Vac Insulation resistance Vdc Bridge resistance 700 ohm Shunt calibration data Included termination (std) PTIH-10-6P or equivalent (hermetic stainless) Mechanical Maximum allowable load 150 % FS 1 Case material Stainless steel Deflection full scale 0,076 mm [0.003 in] Life cycles (approx) >10 million cycles 254 Questions? Contact us at either , Specifications subject to change.

113 Option codes Load ranges Temperature compensation Internal amplifiers Internal amp enhancements termination Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see honeywell.com/tmsensor-ship for updated listings. 2K, 3K, 5K, 10K, 15K, 25K, 50K lb 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 1d. -20 F to 130 F 1e. -20 F to 200 F 1f. 70 F to 250 F 2u. Unamplified, mv/v output 2b. 4 wire, ±5 Vdc output 2c. 0 Vdc to 5 Vdc 3a. Input/output isolation 7 3d. Remote buffered shunt calibration 6a. Bendix PTIH-10-6P (or equivalent) 6-pin, (max. 250 F) 6b. MS connector MS3102E-14S-6P (mates with MS3106E-14S-6), (max. 160 F) 6 6e. Integral cable: Teflon 6f. Integral cable: PVC Shunt calibration 8a. Precision internal resistor 8 Bridge type 11a. Square bridge 8 11b. Symmetrical bridge 8 11c. Square and symmetrical bridge 8 31a. Dual bridge Bridge resistance Zero and span adjustment connector orientation Shock and vibration 12b ohm (foil) (max. 250 F) 14a. No access to zero and span adjustment 15a. Horizontal electrical exit port orientation 15b. Vertical electrical exit port orientation 15c. Radial electrical exit port orientation 15d. Connector on end of cable 44a. Shock and vibration resistance Interfaces 53e. Signature calibration 8 53t. TEDS IEEE module 9 1g. 70 F to 325 F 8 1h. 70 F to 400 F 8 1i. -65 F to 250 F 8 1j. 0 C to 50 C 1k. -20 C to 85 C 1m. -25 C to 110 C 2j. 4 ma to 20 ma (three-wire) output 2k. 4 ma to 20 ma (two-wire) 12 2t. 0 Vdc to 10 Vdc output 6g. Integral cable: Neoprene 6h. Integral cable: Silicone 6i. Integral underwater cable 6j. 1/2-14 conduit fitting with 5 ft of 4 conductor PVC cable 6q. Integral cable: Polyurethane 6v. Phoenix connector on end of cable Internal amplifiers Amplifier specifications Output signal Input power (voltage) Input power (current) Freq. resp (amp) Power supply rej. Operating temp. Reverse voltage protection Short cir. protection Wiring code: connector (std) 4 Wiring code: cable 4,5,6 Voltage output: Option 2b Voltage output: Option 2c ±5 V 0 V to 5 V or ±5 45 ma ±15 V or 26 Vdc to 32 Vdc 11 Vdc to 28 Vdc Voltage output: Option 2t 0 V to 10 V or ±10 45 ma 15 Vdc to 28 Vdc Current three-wire: Option 2j 4 ma to 20 ma 22 Vdc to 32 Vdc Current two-wire: Option 2k 4 ma to 20 ma 15 Vdc to 40 Vdc 45 ma 40 ma 40 ma 65 ma 4 ma to 28 ma Intrinsically safe amp: Option 2n (2N)*** 4 ma to 20 ma 9 Vdc to 28 Vdc 4 ma to 24 ma 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz 60 db 60 db 60 db 60 db 60 db 60 db -20 F to 185 F -20 F to 185 F -20 F to 185 F 0 F to 185 F 0 F to 185 F -20 F to 185 F Yes Yes Yes Yes Yes Yes Momentary Momentary Momentary Yes Yes Yes B Output common C Supply return E Shunt cal 1 F Shunt cal 2 Bl Output common G Supply return W (+) Output B Shunt cal 1 Br Shunt cal 2 B Output common** C Supply return ** E Shunt cal 1 F Shunt cal 2 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 B Output common** C Supply return** E Shunt cal 1 F Shunt cal 2 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 B Output common** C Supply return** E Shunt cal 1 F Shunt cal 2 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 B No connection C No connection E Case ground F No connection Bl (+) Output W Case ground * Black and green wires are internally connected. ** Pins B and C are internally connected. *** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. # B No connection C No connection E Case ground F No connection Bl (+) Output W Case ground Wiring codes Allowable maximum loads 2 Connector A B C D E F Unamplified (std.) (+) excitation (+) excitation (-) excitation (-) excitation (-) output (+) output Capacity (lb) Side load (lb) (% of load capacity) % 20% % 20% % 20% % 20% % 20% % 20% % 20% Torque (lb-in) (% of load capacity) Specifications subject to change. Questions? Contact us at either , 255

114 Mounting dimensions and characteristics Typical system diagram Unamplified only Amplified only (lb) D mm T L2 mm L1 mm A mm B mm E mm F mm 2000 to ,45 [1.75] 3/4-16 UNF 24,13 [0.95] 90,42 [3.56] 19,05 [0.75] 20,82 [0.82] 49,53 [1.95] 38,1 [1.50] to ,5 [2.50] 1 1/2-12 UNF 44,45 [1.75] 155,54 [6.12] 19,05 [0.75] 20,82 [0.82] 49,53 [1.95] 38,1 [1.50] to ,9 [3.50] 2-12 UNF 57,15 [2.25] 203,2 [8.00] 19,05 [0.75] 20,82 [0.82] 49,53 [1.95] 38,1 [1.50] Deflections and ringing frequencies Capacity (lb) Deflection at full scale mm Ringing frequency (Hz) Weight kg [lb] ,025 [0.001] ,54 [1.2] ,025 [0.001] ,54 [1.2] ,050 [0.002] ,63 [1.4] ,050 [0.002] ,31 [2.9] ,050 [0.002] ,31 [2.9] ,050 [0.002] ,30 [9.5] ,076 [0.003] ,49 [9.9] Special requirements (consult factory) Have a special requirement? New diameter cable, different cable lengths, radiation proof, output option, temperature settings, TEDS IEEE modules, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. 256 Questions? Contact us at either , Specifications subject to change.

115 Model 3161 Tension/ Compression In-Line Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code and the desired load range in lbs. For example: Order code Order codes Load range 3161 Model 3161 tension/compression in-line load cell code DL DR DV EM 2000 lb 5000 lb lb lb Adapts directly to hydraulic cylinder Small diameter allows mounting in restricted areas High capacities vs. size Low deflection Notes 1. This unit calibrated to Imperial (non-metric) units. Specifications Performance Load range , 5000, 10000, lb Non-linearity ±0.15 % of rated output Hysteresis ±0.1 % of rated output Repeatability ±0.05 % of rated output rated capacity ±2 mv/v (nominal) Operation Tension/compression Resolution Infinite Standard calibration Environmental Temperature, operating -54 C to 93 C [-65 F to 200 F] Temperature, compensated 21 C to 77 C [70 F to 170 F] Temperature effect, zero ±0.002 % of rated output/ F Temperature effect, output ±0.002 % of reading/ F Strain gage type Foil Excitation (maximum) 20 Vdc or Vac RMS Insulation resistance > Vdc Bridge resistance (tolerance) 350 ohm Number of bridges 1 or 2 Zero balance ±1.0 % Mechanical Static overload capacity 150 % of nominal capacity Material Carbon steel Natural frequency below Mechanical characteristics Nominal load limit capacity F z lb N Static overload capacity (% of nominal capacity) Fatigue capacity (% of nominal capacity) Static extraneous load limits Shear F X or F Y (lb) Bending M X or M Y (lb-in) Torque M Z (lb-in) Deflection at nominal load limit (in) 2K 10K K 20K K 50K K 125K Ringing frequency (Hz) Specifications subject to change. Questions? Contact us at either , 257

116 SETUP LOAD CELLS Mounting dimensions and characteristics Typical system diagram Model A cm ,48 [6.88] B cm C cm 2,54 [1.0] 11,28 [4.44] G OPTIONAL DUAL BRIDGE D cm 4,29 [1.69] E cm 6,05 [2.38] RECEP. PT02E-10-6P THD. B DEEP F cm 1,27 [0.50] G cm 4,14 [1.63] H cm 0,64 [0.25] In-Line Amplifiers (Used with unamplified units only) Amplifier Output Universal In-Line Amplifiers UV +/-5 VDC UV-10 +/-10 VDC UBP 0 +/-5 VDC U3W 4-20mA (3 wire) U2W 4-20mA (2 wire) DIN rail Mount In-Line Amplifiers DV /- 5 VDC (3 wire) DA mA (3 wire) DV10 0 +/- 10 VDC (3 wire) Customer Supplied Chart Recorder Alarm Panel Data Acquisition Computer PLC Power Supply Honeywell In-Line Amplifier Output Input Serial Number D THD. MODEL 3161 Display Units C SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH PSD OR lb. L1 L2 L3 L4 VALUE CLEAR CHAN TARE UP DOWN ENTER EXIT C For reference only D E F OPTIONAL DUAL BRIDGE 9/32 DIA. M DEEP 4 HOLES EQUALLY SPACED FOR SPANNER WRENCH Mating Connectors & Cables 023-LW LF Mating Connector XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal) XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal) XX* Mating connector & 6 conductor cable (for connection to instrument 7541) XX** Mating connector & 4 conductor cable (for connection to instrument 7541) * XX represents length in feet 100ft maximum ** XX represents length in feet 20ft maximum 258 Questions? Contact us at either , Specifications subject to change.

117 Model 3124 Tension/ Compression In-Line Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code and the desired load range code. For example: 3124 DR Order code Order codes code 3124 Model 3124 tension/compression in-line load cell code DR DV EJ EL EM 5000 lb lb lb lb lb Adapts directly to hydraulic cylinder Small diameter allows mounting in restricted areas High capacities vs. size Low deflection Notes 1. This unit calibrated to Imperial (non-metric) units. Specifications Performance Load range , 10000, 15000, 20000, lb Non-linearity ±0.25 % of rated output Hysteresis ±0.15 % of rated output Repeatability ±0.05 % of rated output rated capacity ±2 mv/v (nominal) Operation Tension/compression Resolution Infinite Standard calibration Environmental Temperature, operating -54 C to 93 C [-65 F to 200 F] Temperature, compensated 21 C to 77 C [70 F to 170 F] Temperature effect, zero ±0.002 % of rated output/ F Temperature effect, output ±0.002 % of reading/ F Strain gage type Foil Excitation (maximum) 20 Vdc or Vac RMS Insulation resistance > Vdc Bridge resistance (tolerance) 350 ohm Number of bridges 1 or 2 Zero balance ±1.0 % Mechanical Static overload capacity 150 % of nominal capacity Material Carbon steel Natural frequency below Mechanical characteristics Nominal load limit capacity F z lb N Static overload capacity (% of nominal capacity) Fatigue capacity (% of nominal capacity) Static extraneous load limits Shear F X or F Y (lb) Bending M X or M Y (lb-in) Torque M Z (lb-in) Deflection at nominal load limit (in) 5K 20K 150 n/a K 50K 150 n/a K 75K 150 n/a K 100K 150 n/a K 125K 150 n/a Ringing frequency (Hz) Specifications subject to change. Questions? Contact us at either , 259

118 SETUP LOAD CELLS Mounting dimensions and characteristics Typical system diagram Model A cm ,43 [4.50] E HEX THD. B cm C cm 2,54 [1.0] 0,97 [0.38] H D cm 2,06 [0.81] E cm 3,81 [1.50] RECEP. MS-3102E-14S-5P F cm 3,51 [1.38] G cm 6,20 [2.44] H cm 4,37 [1.72] In-Line Amplifiers (Used with unamplified units only) Amplifier Output Universal In-Line Amplifiers UV +/-5 VDC UV-10 +/-10 VDC UBP 0 +/-5 VDC U3W 4-20mA (3 wire) U2W 4-20mA (2 wire) DIN rail Mount In-Line Amplifiers DV /- 5 VDC (3 wire) DA mA (3 wire) DV10 0 +/- 10 VDC (3 wire) Customer Supplied Chart Recorder Alarm Panel Data Acquisition Computer PLC Power Supply B Honeywell In-Line Amplifier Output Input Serial Number C Display Units A MODEL 3124 SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH PSD G D OR lb. L1 L2 L3 L4 VALUE CLEAR CHAN TARE UP DOWN ENTER EXIT For reference only F DIA. E DIA THD. B DEEP Mating Connectors & Cables 064-LW13621 Mating connector XX* Mating connector and six conductor cable (unamplified unit with sense leads but not shunt cal) XX** Mating connector (MS - 5 pin) and four conductor cable (unamplified sensor without sense leads) XX** Mating connector ( MS 5 pin ) & 6 conductor cable for connection to XX** Mating connector ( MS 5 pin ) & 4 conductor cable for connection to 7541 * XX represents length in feet 100ft maximum ** XX represents length in feet 20ft maximum Special requirements (consult factory) Have a special requirement? New case pressure, different cable lengths, electrical connectors, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. 260 Questions? Contact us at either , Specifications subject to change.

119 Model 102 Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code and range code. For example: BL804 LD Order code code Order codes BL804 Model 102 load cell Low cost 20 kg to 1000 kg range ±0.02 % accuracy LD LE LF LG 20 kg 30 kg 50 kg 75 kg LK LL LM LN 200 kg 250 kg 300 kg 500 kg LH 100 kg LQ 1000 kg LJ 150 kg Notes 1. Allowable maximum loads maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 3. This unit is calibrated to Metric (non-imperial) units. Specifications Performance Load ranges 3 20, 50, 100, 200, 300, 500, 1000 kg Accuracy ±0.02 % full scale Output 2.0 mv/v Creep (max.) ±0.02 % full scale (30 minutes) Environmental Temperature, operating -30 C to 70 C [-22 F to 158 F] Temperature, compensated -20 C to 55 C [-4 F to 131 F] Temperature effect, zero ±0.02 % full scale/10 C Temperature effect, span ±0.02 % full scale/10 C Protection class IP67 Strain gage type Bonded foil Excitation (acceptable) 10 Vdc to 12 Vdc Excitation (max.) 15 Vdc Insulation resistance > 5000 mohm Bridge resistance (tolerance) Input resistance 400 ohm ±10 ohm (nominal) Output resistance 352 ohm ±2 ohm (nominal) Zero balance (tolerance) ±1 % full scale termination (std) 3 m [9.84 ft] flying leads Mechanical Maximum allowable load 150 full scale 1 Material Nickel plated alloy steel or stainless steel Deflection Less than or equal to 0,5 mm [0.02 in] Specifications subject to change. Questions? Contact us at either , 261

120 Mounting dimensions and characteristics Wiring codes Load D (thread) L 20 kg to 150 kg M8 x mm [0.47 in] 200 kg to 500 kg M12 x mm [0.79 in] 700 kg to 1000 kg M12 x mm [0.98 in] Cable Red Black Green White Large black (+) supply (-) supply (+) output (-) output Shield Typical system diagram Special requirements (consult factory) Have a special requirement? New case pressure, different cable lengths, electrical connectors, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. 262 Questions? Contact us at either , Specifications subject to change.

121 Model 123 Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the model code and the range code. For example: BL810 LR Model code code Order codes BL810 Model 123 load cell Low cost 1000 kg to kg range ±0.03 % accuracy Specifications Performance Load ranges kg to kg Accuracy ±0.03 % full scale Output 2.0 mv/v Creep (max.) ±0.03 % full scale (30 minutes) Environmental Temperature, operating -30 C to 70 C [-22 F to 158 F] Temperature, compensated -20 C to 55 C [-4 F to 131 F] Temperature effect, zero ±0.03 % full scale/10 C Temperature effect, span ±0.03 % full scale/10 C Protection class IP67 3 Strain gage type Foil Excitation (acceptable) 10 Vdc to 12 Vdc Excitation (max.) 15 Vdc Insulation resistance > 5000 mohm Bridge resistance (tolerance) Input resistance 400 ohm ±10 ohm (nominal) Output resistance 352 ohm ±2 ohm (nominal) Zero balance (tolerance) ±1 % full scale termination (std) 6 m [19.69 ft] of 5 mm [0.2 in] diameter cable Mechanical Maximum allowable load 120 % full scale 1 Later load limit 100 % full scale Material Nickel plated alloy steel LQ 1000 kg LV 7500 kg LR 1500 kg LW kg LS 2000 kg LY kg LT 3000 kg LZ kg LU 5000 kg Wiring codes Cable Red (+) supply Black (-) supply Green (+) output White (-) output Large black Shield Mounting dimensions and characteristics (kg) A B C D 1000, mm [3.15 in] 70 mm [2.76 in] 25 mm [0.98 in] M12 x , 3000, mm [4.25 in] 95 mm [3.75 in] 25 mm [0.98 in] M18 x , mm [7.00 in] 130 mm [5.12 in] 51 mm [2.0 in] M30 x , mm [7.48 in] 160 mm [6.3 in] 60 mm [2.36 in] M30 x 2 Typical system diagram Notes 1. Allowable maximum loads maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 3. IP68 rating for load ranges 7500 kg and greater. 4. This unit is calibrated to Metric (non-imperial) units. Mounting dimensions and characteristics For reference only Specifications subject to change. Questions? Contact us at either , 263

122 Model 127 Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the model code and the range code. For example: BL807 LH Model code code Order codes BL807 Model 127 load cell Low cost 50 kg, 100 kg range 0.03 % accuracy LF LH 50 kg 100 kg Specifications Performance Load ranges 3 50 kg, 100 kg Accuracy ±0.03 % full scale Output 3.0 mv/v Creep (max.) ±0.03 % full scale (30 minutes) Environmental Temperature, operating -30 C to 70 C [-22 F to 158 F] Temperature, compensated -20 C to 55 C [-4 F to 131 F] Temperature effect, zero ±0.03 % full scale/10 C Temperature effect, span ±0.03 % full scale/10 C Protection class IP67 Strain gage type Bonded foil Excitation (acceptable) 10 Vdc to 12 Vdc Excitation (max.) 15 Vdc Insulation resistance > 5000 mohm Bridge resistance (tolerance) Input resistance 400 ohm ±10 ohm Output resistance 352 ohm ±2 ohm Zero balance (tolerance) ±1 % full scale termination (std) 5 m [16.40 ft] flying leads Mechanical Maximum allowable load 150 % full scale 1 Case material Nickel plated alloy steel Wiring codes Cable Red Black Green White Large black Notes (+) supply (-) supply (+) output (-) output Shield 1. Allowable maximum loads maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 3. This unit is calibrated to Metric (non-imperial) units. Typical system diagram Mounting dimensions and characteristics For reference only 264 Questions? Contact us at either , Specifications subject to change.

123 Model 125 Load Cell How to order: (Quick-ship range/option combinations available. See Web site.): Combine the model code and the range code. For example: BL811 LH Model code code Order codes BL811 Model 125 load cell Low cost 100 kg to 500 kg range 0.02 % accuracy LH LK LM LN 100 kg 200 kg 300 kg 500 kg Specifications Performance Load ranges 3 100, 200, 300, 500 kg Accuracy ±0.02 % full scale Output 2.0 mv/v Creep (max.) ±0.02 % full scale (30 minutes) Environmental Temperature, operating -30 C to 70 C [-22 F to 158 F] Temperature, compensated -20 C to 55 C [-4 F to 131 F] Temperature effect, zero ±0.02 % full scale/10 C Temperature effect, span ±0.02 % full scale/10 C Protection class IP67 Strain gage type Bonded foil Excitation (acceptable) 10 Vdc to 12 Vdc Excitation (max.) 15 Vdc Insulation resistance > 5000 mohm Bridge resistance (tolerance) Input resistance 400 ohm ±10 ohm Output resistance 352 ohm ±2 ohm Zero balance (tolerance) ±1 % full scale termination (std) Mating connector and 5 m [16.40 ft] cable (included) Mechanical Maximum allowable load 150 % FS 1 Case material Nickel plated alloy steel Wiring codes Cable Red Black Green White Large black Notes (+) supply (-) supply (+) output (-) output Shield 1. Allowable maximum loads maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 3. This unit is calibrated to Metric (non-imperial) units. Typical system diagram Mounting dimensions and characteristics For reference only Specifications subject to change. Questions? Contact us at either , 265

124 Model 129 Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the model code and the range code. For example: BL808 LS Model code code Order codes BL808 Model 129 load cell Low cost 1000 kg to 5000 kg range 0.02 % accuracy LQ LS 1000 kg 2000 kg LT LU 3000 kg 5000 kg Specifications Performance Load ranges , 2000, 3000, 5000 kg Accuracy ±0.02 % full scale Output 2.0 mv/v Creep ±0.02 % full scale (30 minutes) Environmental Temperature, operating -30 C to 70 C [-22 F to 158 F] Temperature, compensated -20 C to 55 C [-4 F to 131 F] Temperature effect, zero ±0.02 % full scale/10 C Temperature effect, span ±0.02 % full scale/10 C Protection class IP67 Strain gage type Bonded foil Excitation (acceptable) 10 Vdc to 12 Vdc Excitation (max.) 15 Vdc Insulation resistance > 5000 mohm Bridge resistance (tolerance) Input resistance 400 ohm ±10 ohm Output resistance 352 ohm ±2 ohm Zero balance (tolerance) ±1 % full scale termination (std) 5 m [16.40 ft] flying leads Mechanical Maximum allowable load 150 % FS 1 Case material Nickel plated alloy steel Wiring codes Cable Red Black Green White Large black Notes (+) supply (-) supply (+) output (-) output Shield 1. Allowable maximum loads maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 3. This unit is calibrated to Metric (non-imperial) units. Typical system diagram Mounting dimensions and characteristics For reference only 266 Questions? Contact us at either , Specifications subject to change.

125 Model MBL Minigram Beam Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: BL341 AH 1b Order codes BL341 Order code code Option code Model MBL minigram beam load cell 25 g to 1000 g Miniature size 0.1 % linearity AH AJ AK AL AN AP AR 25 g 50 g 100 g 150 g 250 g 500 g 1000 g Notes 1. Positive in compression; calibrated in compression only. 2. Allowable maximum loads maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 4. This unit calibrated to Imperial (non-metric) units. Specifications Performance Load ranges 4 Linearity (max.) Hysteresis (max.) Non-repeatability (max.) Output (tolerance) Operation Tension/compression 1 Resolution Infinite 25, 50, 100, 150, 250, 500, 1000 g ±0.1 % full scale ±0.1 % full scale ±0.03 % full scale 20 mv/v (nominal) Environmental Temperature, operating -18 C to 93 C [0 F to 200 F] Temperature, compensated 15 C to 71 C [60 F to 160 F] Temperature, storage -73 C to 93 C [-100 F to 200 F] Temperature effect, zero % full scale/ F Temperature effect, span 0.02 % full scale/ F Strain gage type Bonded semiconductor Excitation (calibration) 5 Vdc Insulation resistance Vdc Bridge resistance 500 ohm Zero balance ±5 % full scale termination (std) Cable 1,83 m [5 ft] Mechanical Maximum allowable load 400 % FS 2 Weight 50 g Material Aluminum Specifications subject to change. Questions? Contact us at either , 267

126 Option codes Wiring codes Load range Temperature compensation Internal amplifiers termination Special calibration Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see for updated listings. 25, 50, 100, 150, 250, 500, 1000 g 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 2u. Unamplified, mv/v output 6e. Integral cable: Teflon 6d. Microtec DR-4S-4H four-pin 9a. 10 point (5 up/5 down) 20 % 70 F Cable Unamplified Red (+) excitation Black (-) excitation Green (-) output White (+) output Typical system diagram Mounting dimensions and characteristics For reference only Special requirements (consult factory) Have a special requirement? New case pressure, different cable lengths, electrical connectors, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. 268 Questions? Contact us at either , Specifications subject to change.

127 Model MBH Minigram Beam Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: BL342 AL 1b Order codes BL342 Order code code Option code Model MBH minigram beam load cell 150 g to 10 lb range Miniature size 0.1 % linearity AL AN AP AR AT AV 150 g 250 g 500 g 1000 g 5 lb 10 lb Notes 1. Positive in compression; calibrated in compression only. 2. Allowable maximum loads maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 4. This unit calibrated to Imperial (non-metric) units. Specifications Performance Load ranges 4 Linearity (max.) Hysteresis (max.) Non-repeatability (max.) Output (tolerance) Operation Tension/compression 1 Resolution Infinite 150, 250, 500, 1000 g; 5, 10 lb ±0.1 % full scale ±0.1 % full scale ±0.03 % full scale 20 mv/v (nominal) Environmental Temperature, operating -18 C to 71 C [0 F to 160 F] Temperature, compensated 15 C to 71 C [60 F to 160 F] Temperature, storage -73 C to 93 C [-100 F to 200 F] Temperature effect, zero % full scale/ F Temperature effect, span % full scale/ F Strain gage type Bonded foil Excitation (calibration) 5 Vdc Insulation resistance Vdc Bridge resistance 350 ohm Zero balance ±5 % full scale termination (std) Cable 1,83 m [5 ft] Mechanical Maximum allowable load 400 % full scale or 20 lb, whichever is less 2 Weight 50 g Material Aluminum Specifications subject to change. Questions? Contact us at either , 269

128 Option codes Wiring codes Load range Temperature compensation Internal amplifiers termination Special calibration Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see for updated listings. 150, 250, 500, 1000 g; 5, 10 lb 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 2u. Unamplified, mv/v output 6e. Integral cable: Teflon 6d. Microtec DR-4S-4H four-pin 9a. 10 point (5 up/5 down) 20 % 70 F Cable Unamplified Red (+) excitation Black (-) excitation Green (-) output White (+) output Typical system diagram Mounting dimensions and characteristics For reference only Special requirements (consult factory) Have a special requirement? New case pressure, different cable lengths, electrical connectors, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. 270 Questions? Contact us at either , Specifications subject to change.

129 Model LP Force Sensing Clevis Pin How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: AL441 DV 2b Order code code Option code Order codes AL441 Model LP force sensing clevis pin DL 2000 lb EN lb All welded construction Amplified output available Intrinsically safe available (2N option only) 8 CE approved 9 DN DR DS DV DW EL 3000 lb 5000 lb 6000 lb lb lb lb EP ER ET FH FJ FL lb lb lb lb lb lb Notes 1. Allowable maximum loads Maximum load to be applied without damage. 2. Only available with option 2b or 2c. 3. Not available with amplified option. 4. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal provides 50 % (unamplified units), 75 % (4 ma to 20 ma threewire units) or 80 % (voltage amplified units) of full scale output for quick calibration. Shunt calibration comes standard with internal amplifier option 2a, 2b, 2c, 2t and 2j. 5. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown; W=White; G=Green. Color specifying cable and number or letter specifying connector. 6. No mating connector necessary for cable option. 7. Consult factory for TEDS availability with amplified models. 8. dependent; consult factory. Termination dependent; consult factory. 9. Internal amp and termination dependent; consult factory. 10. This unit calibrated to Imperial (non-metric) units ohm bridge required. Specifications Performance Load ranges , 3000, 5000, 6000, 10000, 12500, 20000, 30000, 50000, 75000, , , , and lb Linearity (max.) from ±0.5 % full scale (consult factory) Hysteresis from ±0.5 % full scale (consult factory) Non-repeatability ±0.15 % full scale Tolerance on output 1 mv/v nominal Environmental Temperature, operating -54 C to 93 C [-65 F to 250 F] Temperature, compensated 15 C to 54 C [60 F to 160 F] Temperature effect, zero % full scale/ F Temperature effect, span % of load/ F Strain gage type Foil Excitation (calibration) 10 Vdc Bridge resistance 5000 ohm termination (std) PTIH-10-6P Mating connector (not incl.) PT06A-10-6S or equivalent (AA111) Mechanical Maximum allowable load 200 % FS 1 Case material 17-4 PH stainless steel Specifications subject to change. Questions? Contact us at either , 271

130 Option codes Internal amplifiers Load ranges Temperature compensation Internal amplifiers amp enhancements termination Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see honeywell.com/tmsensor-ship for updated listings. 2k, 3k, 5k, 6k, 10k, 12.5k, 15k, 20k, 30k, 50k, 75k, 100k, 125k, 150k, 200k lb 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 1d. -20 F to 130 F 1e. -20 F to 200 F 1f. 70 F to 250 F 2a. Four-wire 0 Vdc to 5 Vdc output 2c. 0 Vdc to 5 Vdc output 2j. 4 ma to 20 ma (three-wire) output 2k. 4 ma to 20 ma (two-wire) output 11 3a. Input/output isolation 2 3d. Remote buffered shunt calibration 6a. Bendix PTIH-10-6P (or equivalent) 6-pin (max. 250 F) 6b. MS connector MS3102E-14S-6P (mates with MS3106E-14S-6S) (max. 160 F) 6f. Integral cable: PVC 6g. Integral cable: Neoprene Shunt calibration 8a. Precision internal resistor 3 Special calibration Bridge resistance Zero and span adjustment 9e. CE mark 9a. 10 point (5 up/5 down) 20 % 70 F 9b. 20 point (10 up/10 down) 10 % 70 F 9c. ASTM E-74 calibration 12b ohm (foil) 14a. No access to zero and span adjustment 1g. 70 F to 325 F 3 1i. -65 F to 250 F 3 1j. 0 C to 50 C 1k. -20 C to 85 C 1m. -25 C to 110 C 2n (2N) 4 ma to 20 ma (two-wire) intrinsically safe 11 2t. 0 Vdc to 10 Vdc 2u. Unamplified, mv/v output 6h. Integral cable: Silicone 6i. Integral underwater cable 6j. 1/2-14 conduit fitting with 5 ft of four conductor PVC cable 6q. Molded integral cable: Polyurethane 6v. Phoenix connector at end of cable 15d. Connector on end of cable Amplifier specifications Output signal Input power (voltage) Input power (current) Freq. resp (amp) Power supply rej. Operating temp. Reverse voltage protection Short cir. protection Wiring code: connector (std) 4 Voltage output: Option 2a Voltage output: Option 2c 0 V to 5 V 0 V to 5 V or ±5 45 ma ±15 V or 26 Vdc to 32 Vdc 11 Vdc to 28 Vdc Voltage output: Option 2t 0 V to 10 V or ±10 45 ma 15 Vdc to 28 Vdc Current three-wire: Option 2j Current two-wire: Option 2k Intrinsically safe amp: Option 2n (2N)*** 4 ma to 20 ma 4 ma to 20 ma 4 ma to 20 ma 22 Vdc to 32 Vdc 15 Vdc to 40 Vdc 9 Vdc to 28 Vdc 45 ma 40 ma 40 ma 65 ma 4 ma to 28 ma 4 ma to 24 ma 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz 60 db 60 db 60 db 60 db 60 db 60 db -20 F to 185 F -20 F to 185 F -20 F to 185 F 0 F to 185 F 0 F to 185 F -20 F to 185 F Yes Yes Yes Yes Yes Yes Momentary Momentary Momentary Yes Yes Yes B Output common C Supply return E Shunt cal 1 F Shunt cal 2 B Output common** C Supply return ** E Shunt cal 1 F Shunt cal 2 B Output common** C Supply return** E Shunt cal 1 F Shunt cal 2 B Output common** C Supply return** E Shunt cal 1 F Shunt cal 2 B No connection C No connection E Case ground F No connection B No connection C No connection E Case ground F No connection Special calibration Shock and vibration 30a. Compression only (+) output 30b. Tension and compression (+,-) output 30c. Compression only (-) output 44a. Shock and vibration resistance Interfaces 53e. Signature calibration 3 53t. TEDS IEEE module 7 Wiring code: cable 4,5,6 Bl Output common G Supply return W (+) Output B Shunt cal 1 Br Shunt cal 2 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 Bl (+) Output W Case ground * Black and green wires are internally connected. ** Pins B and C are internally connected. *** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. # Installation Bl (+) Output W Case ground Standard uses for clevis pins include tongue and yoke shackles and tension pulleys. Clevis pins are also often ideal for use in web tension applications. Consult factory for web tension measurement kits from 200 lb to lb. Special requirements (consult factory) Have a special requirement? New case pressure, different cable lengths, electrical connectors, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. 272 Questions? Contact us at either , Specifications subject to change.

131 Mounting dimensions and characteristics Capacity lb A mm ** B mm C mm D mm F mm G mm H mm J mm Key mm SRG* N mm 2000, ,7 [0.500] 12,7 [0.50] 19,05 [0.75] 38,1 [1.50] 101,09 [3.98] 6,35 [0.25] 5,08 [0.20] 6,35 [0.25] NA 11,89 [0.468] 0,99 [0.039] 5000, ,05 [0.750] 14,99 [0.59] 25,4 [1.00] 38,1 [1.50] 113,79 [4.48] 7,87 [0.31] 5,08 [0.20] 6,35 [0.25] 3,96 [0.156] 17,88 [0.704] 1,17 [0.046] 10000, ,4 [1.00] 16 [0.63] 25,4 [1.00] 38,1 [1.50] 120,4 [4.74] 12,7 [0.50] 5,08 [0.20] 6,35 [0.25] 5,56 [0.219] 23,88 [0.940] 1,17 [0.046] 15000, ,75 [1.250] 20,57 [0.81] 35,05 [1.38] 50,8 [2.00] 144,53 [5.69] 16 [0.63] 6,86 [0.27] 6,35 [0.25] 5,56 [0.219] 29,87 [1.176] 1,42 [0.056] ,1 [1.50] 23,88 [0.94] 41,40 [1.63] 50,8 [2.00] 157,48 [6.20] 16 [0.63] 6,86 [0.27] 6,35 [0.25] 7,14 [0.281] 35,71 [1.406] 1,42 [0.056] Capacity lb A mm ** B mm C mm D mm F mm G mm H mm J mm Key mm ,8 [2.000] 25,4 [1.00] 50,8 [2.00] 38,1 [1.50] 167,89 [6.61] 19,05 [0.75] 6,76 [0.266] 9,65 [0.38] 7,14 [0.281] ,5 [2.500] 31,75 [1.25] 63,5 [2.50] 50,8 [2.00] 193,29 [7.61] 19,05 [0.75] 6,76 [0.266] 12,7 [0.50] 7,14 [0.281] ,85 [2.750] 37,34 [1.47] 69,85 [2.69] 50,8 [2.00] 219,20 [8.63] 25,4 [1.00] 10,31 [0.406] 12,7 [0.50] 10,31 [0.406] ,2 [3.000] 36,58 [1.44] 76,2 [3.00] 50,8 [2.00] 225,55 [8.88] 25,4 [1.00] 10,31 [0.406] 16 [0.63] 10,31 [0.406] ,9 [3.500] 44,45 [1.75] 88,9 [3.50] 50,8 [2.00] 263,65 [10.38] 31,75 [1.25] 13,49 [0.531] 16 [0.63] 13,49 [0.531] ,6 [4.000] 57,15 [2.25] 101,6 [4.00] 50,8 [2.00] 301,75 [11.88] 31,75 [1.25] 13,49 [0.531] 19,05 [0.75] 13,49 [0.531] *SRG - Snap ring groove diameter **Tolerance = in/ in Typical system diagram Wiring codes Connector A B C D E F Unamplified (Std.) (+) excitation (+) excitation (-) excitation (-) excitation (-) output (+) output Specifications subject to change. Questions? Contact us at either , 273

132 Model LK Digital Force Indicator How to order: (Quick-ship range/option combinations available. See Web site.) Enter the series, order code, pressure range, reference, electrical termination and option code. For example. LK W 1000 K Z 4 Series Order code Load range Reference termination Other options Order codes (see chart) Model LK digital force indicator Series Order code Load range 2 Reference termination 3 Order codes LK W = battery V = vehicle powered T = ac adaptor included Load range in lb K = compression T = tension C = compound Z = no connector C = cable exit T = ac adaptor Other options 4 = NEMA 4 rating Model LK shown with optional handle. Visit our Web site for more information on optional handles. Accessories order codes HD1 Handle CC2 Standard carrying case (3 9/16 in x 7 13/16 in x 8 1/2 in) MR2 Panel mounting ring NISTcerts NIST certification (in addition to NIST statement) Specifications s to lb Tension and compression measurement High and low force capture Zero offset/tare NIST statement Field selectable engineering units (lb, N, kn, g, kg) Customer recalibration Notes 1. Accuracies stated are for best fit straight line for all errors including linearity, hysteresis and repeatability through zero. 2. Consult factory for optional units of measure. 3. Consult factory for optional electrical connectors and cable lengths. Performance See additional specifications table Repeatability 0.2 % 1 Update speed 3 per second (selectable to 10/second) Environmental Temperature, operating -1 C to 71 C [30 F to 160 F] Rating NEMA 2 (NEMA 4 optional except model LKT) Display LCD, 4 1/2-digit, 1,3 cm [0.5 in] high Power supply, Model LKW 1 or 2 9-volt batteries (included) Power supply, Model LKT 110 volt ac 60 Hz (included) Power supply, Model LKV 11 Vdc to ma connection 0,9 m [3 ft] cable (std.) for model LKV Low battery indication Standard on model LKW Calibration data Stored on memory chip Zero and span adjustment Standard Mechanical Case material Stainless steel Field selectable standard units of measure 2 (lb is standard) N kn g kg Newton Kilonewton Grams Kilograms 274 Questions? Contact us at either , Specifications subject to change.

133 Mounting dimensions and characteristics s (lb) T D H C F A B 1 lb #6-32 UNC 25,4 mm [1.00 in] 5 to 10 lb #6-32 UNC 25,4 mm [1.00 in] 25 to 100 lb 250 to 1000 lb 2000 to 3000 lb 4000 to 5000 lb 7500 to lb #10-32 UNF 1/4-28 UNF 3/8-24 UNF 1/2-20 UNF 3/4-16 UNF 25,4 mm [1.00 in] 25,4 mm [1.00 in] 25,4 mm [1.00 in] 32,0 mm [1.25 in] 35 mm [1.38 in] 19,5 mm [0.75 in] 11 mm [0.45 in] 13 mm [0.52 in] 13 mm [0.52 in] 18 mm [0.72 in] 24 mm [0.94 in] 28 mm [1.10 in] 6,4 mm [0.25 in] 6,4 mm [0.25 in] 6,4 mm [0.25 in] 9,7 mm [0.38 in] 12,5 mm [0.50 in] 16 mm [0.63 in] 22 mm [0.88 in] 2,8 mm [0.11 in] 1,3 mm [0.05 in] 0,8 mm [0.03 in] 0,8 mm [0.03 in] 0,8 mm [0.03 in] 0,8 mm [0.03 in] 0,8 mm [0.03 in] 12,5 mm [0.50 in] 7,9 mm [0.31 in] 12,5 mm [0.50 in] 12,5 mm [0.50 in] 12,5 mm [0.50 in] 12,5 mm [0.50 in] 12,5 mm [0.50 in] 9,7 mm [0.38 in] 4,8 mm [0.19 in] 6,4 mm [0.25 in] 6,4 mm [0.25 in] 9,7 mm [0.38 in] 9,7 mm [0.38 in] 9,7 mm [0.38 in] Additional specifications (lb) 0 to 1 0 to 5 0 to 25 0 to 50 0 to to to 500 Incremental display steps (lb) Incremental display steps to to to to to to to For reference only Specifications subject to change. Questions? Contact us at either , 275

134 Model LC: Digital Force Indicator How to order: (Quick-ship range/option combinations available. See Web site.) See order code information below. Order codes See order guide on next page. Model LC shown with optional handle. The Model LC digital force indicator is a highly portable force measurement device. With its 9 V battery supply and compact size the indicator can easily be carried to remote locations to perform force measurement calibrations. The unit can measure compression forces up to 50,000 lbs. The peak capture feature allows the highest force reading taken to be displayed with the push of a button. A zero/tare button is also standard on all models. The remote location of the load sensor minimizes the chance of damage to the electronic body of the gauge. The stainless steel construction of the sensor and the indicator makes them often resistant to the occasional mishandling than can occur in the field. Optional handles are available for the load cell and gauge. See our Web site for more information. Specifications s to lbs Compression measurement High/low force capture Zero offset/tare NIST statement Customer recalibration Selectable engineering units CE compliant Performance Repeatability High and low capture Update speed Power Mechanical Diameter Display Case material Cell materials Zero/span adjustment Low battery indication Face membrane Calibration data 0.2 % of full scale 5 lb to lb Standard 3 per sec (selectable to 10 per sec) 9 V battery, 11 Vdc to 32 Vdc, 100 Vac 93,98 mm [3.7 in] 4½ digits Stainless steel Stainless steel Standard Standard Tactile feedback Stored on memory chip 276 Questions? Contact us at either , Specifications subject to change.

135 Mounting dimensions and characteristics Additional specifications Pressure range (psi) Incremental display steps 0 psi to 1 psi (opt) = psi to 5 psi (opt) = psi to 25 psi = psi to 50 psi = psi to 100 psi = psi to 250 psi = psi to 500 psi = psi to 1000 psi = 1K psi to 2000 psi = 2K psi to 3000 psi = 3K 2 0 psi to 4000 psi = 4L 2 0 psi to 5000 psi = 5K 1 0 psi to 7500 psi = 7.5K 2 0 psi to psi = 10K 2 0 psi to psi = 15K 2 0 psi to psi = 20K 2 0 psi to psi = 30K Consult factory 0 psi to psi = 50K Consult factory For reference only Order guide SERIES LC=0.2% repeatability POWER W=Battery powered (9 V alkaline) T=110 Vac adapter (included) V=11 Vdc to 32 Vdc (3 ft.cable) LC W 100 K Z ( ) PRESSURE RANGE (lb) standard 5=0-5 1K= K=0-10,000 10=0-10 2K= K=0-15,000 25=0-25 3K= K=0-20,000 50=0-50 4K= K=0-30, = K= K-0-50, = K= =0-500 This order code is used ONLY if you want NEMA 4 rating. Accessories order codes Order code Accessory CC2 Standard carrying case: 3 9/16 D x 7 13/16 W x 8 1/2 L MR2 Panel mounting ring NISTCERTS NIST certification (in addition to NIST statement) HD1 Handle REFERENCE K=Compression ELECTRICAL CONNECTION Z= No electrical connection C= 3 foot cable T = ac adapter Call factory for availability of other electrical connections and cable lengths. UNITS OF MEASURE (Field Selectable) Note: lbs is standard n = Newton Kn = Kilonewton g = Grams Kg = Kilograms Consult factory for other units of measure not listed OPTIONAL NEMA 4 CONSTRUCTION 4 = NEMA 4 Specifications subject to change. Questions? Contact us at either , 277

136 Model AL-SC High Output Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: TL131 CV 30a Order code code Option code Order codes TL131 Model AL-SC high output load cell 500 lb, 1000 lb, and 2000 lb range Tension/compression High output/low bridge resistance Drive meters without amplification Low mechanical deflection Notes 1. Static error band is the recommended performance specification. The static error band is calculated as the best fit straight line through zero, including the effects of linearity, hysteresis and nonrepeatability. 2. Allowable maximum loads maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift of performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 4. This unit calibrated to Imperial (non-metric) units. CR CV DL Specifications Performance 500 lb 1000 lb 2000 lb Load ranges 4 Accuracy (static error band) 1 Non-repeatability Output Operation Resolution Environmental Temperature, operating Temperature, compensated Temperature, storage Temperature effect, zero Temperature effect, span Strain gage type Excitation (calibration) Insulation resistance Bridge resistance Input Output Zero balance termination (std) 500, 1000, 2000 lb ±1.25 % full scale ±0.10 % full scale 70 mv/v minimum Tension/compression Infinite -54 C to 93 C [-65 F to 200 F] -12 C to 49 C [10 F to 120 F] -73 C to 121 C [-100 F to 250 F] 0.5 % full scale/ F 1.0 % reading/ F Bonded semiconductor 24 Vdc or Vac (RMS) Vdc 1000 ohm (nominal) 3000 ohm (nominal) 1.5 % full scale (max.) MS3100A-14S-5P at end of 1 ft cable Mechanical Maximum allowable load 200 % full scale 2 Side load without damage 25 % full scale Weight Material 17-4 PH stainless steel Deflection Natural frequency 278 Questions? Contact us at either , Specifications subject to change.

137 Option codes Load range Temperature compensation Internal amplifiers termination Special calibration Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see com/tmsensor-ship for updated listings. 500 lb, 1000 lb, 2000 lb 10 F to 120 F 2u. Unamplified, mv/v output 3106B-14S-5P connector mounted at end of 10 ft cable 30a. Compression only (+) output 30b. Tension and compression (+,-) output 30c. Compression only (-) output Mounting dimensions and characteristics Wiring codes Tension A B C D E Compression A B C D E Deflections and ringing frequencies Capacity (+) excitation (+) signal (-) signal (-) excitation shield (+) excitation (-) signal (+) signal (-) excitation shield Axial deflection at full scale mm Natural frequency (Hz) Weight kg [lb] 500 lb 0,025 mm [0.0010] ,544 [1.2] 1000 lb 0,038 mm [0.0015] ,544 [1.2] 2000 lb 0,051 mm [0.0020] ,544 [1.2] Special requirements (consult factory) Have a special requirement? New case pressure, different cable lengths, electrical connectors, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. Specifications subject to change. Questions? Contact us at either , 279

138 Model AL-JP High Output Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code, range code, and option code. For example: TL121 CV 30a Order code code Option code Order codes TL121 Model AL-JP high output load cell 500 lb, 1000 lb, and 2000 lb range Tension/compression High output/low bridge resistance Drive meters without amplification Low mechanical deflection Notes 1. Static error band is the recommended performance specification. The static error band is calculated as the best fit straight line through zero, including the effects of non-linearity, hysteresis and non-repeatability. 2. Allowable maximum loads maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift of performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 4. This unit calibrated to Imperial (non-metric) units. CR CV DL Specifications Performance s 500 lb 1000 lb 2000 lb Load ranges 4 Accuracy (static error band) 1 Non-repeatability Output Operation Resolution Environmental Temperature, operating Temperature, compensated Temperature, storage Temperature effect, zero Temperature effect, span Strain gage type Excitation (calibration) Insulation resistance Bridge resistance Zero balance termination (std) 500, 1000, 2000 lb ±0.15 % full scale ±0.05 % full scale 30 mv/v minimum Tension/compression Infinite -54 C to 93 C [-65 F to 200 F] -1 C to 54 C [30 F to 130 F] -73 C to 121 C [-100 F to 250 F] 0.5 % full scale/ F 0.5 % reading/ F Mechanical Maximum allowable load 150 % full scale 2 Side load without damage 100 % Weight Material 17-4 PH stainless steel Deflection Natural frequency Bonded semiconductor 5 Vdc or Vac (RMS) Vdc or V 125 ohm nominal (input and output) 3 % full scale (max.) 3106B-14S-5P connector mounted at end of 10 ft cable 280 Questions? Contact us at either , Specifications subject to change.

139 Option codes Load range Temperature compensation Internal amplifiers termination Special calibration Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see com/tmsensor-ship for updated listings. 500 lb, 1000 lb, 2000 lb 10 F to 120 F 2u. Unamplified, mv/v output 3106B-14S-5P connector mounted at end of 10 ft cable 30a. Compression only (+) output 30b. Tension and compression (+,-) output 30c. Compression only (-) output Mounting dimensions and characteristics Wiring codes Tension A (+) excitation B (+) signal C (-) signal D (-) excitation E shield Compression A (+) excitation B (-) signal C (+) signal D (-) excitation E shield Deflections and ringing frequencies Capacity Axial deflection at full scale mm Natural frequency (Hz) Weight kg [lb] 500 lb 0,025 mm [0.0010] ,544 [1.2] 1000 lb 0,038 mm [0.0015] ,544 [1.2] 2000 lb 0,051 mm [0.0020] ,544 [1.2] Special requirements (consult factory) Have a special requirement? New case pressure, different cable lengths, electrical connectors, or materials? Consult our factory by calling ( ). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. Specifications subject to change. Questions? Contact us at either , 281

140 Model 101 Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the model code and the range code. For example: BL803 LL Model code code Order codes BL803 Model 101 load cell Low cost 50 kg to 1000 kg range ±0.02 % accuracy Specifications Performance Load ranges 3 Accuracy Output Creep (max.) Environmental Temperature, operating Temperature, compensated Temperature effect, zero 0.02 % full scale/10 C Temperature effect, span 0.02 % full scale/10 C 50, 100, 250, 500, 1000 kg ±0.02 % full scale 2 mv/v (nominal) ±0.02 % full scale (30 minutes) -30 C to 70 C [-22 F to 158 F] -20 C to 55 C [-4 F to 130 F] Strain gage type Bonded foil Excitation (calibration) 10 Vdc to 12 Vdc Excitation (max.) 15 Vdc Insulation resistance >5000 mohm Bridge resistance (tolerance) Input resistance 400 ohm ±10 ohm (nominal) Output resistance 352 ohm ±2 ohm (nominal) Zero balance (tolerance) ±1 % full scale termination (std) 3 m flying leads Mechanical Maximum allowable load 150 % full scale 1 Material Nickel plated alloy steel Deflection < 2 mm LF LH LL LN LQ Wiring codes Cable Red Black Green White Large black Notes 50 kg 100 kg 250 kg 500 kg 1000 kg (+) supply (-) supply (+) output (-) output shield 1. Allowable maximum loads maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift of performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 3. This unit is calibrated to Metric (non-imperial) units. Typical system diagram Mounting dimensions and characteristics Load (kg) H mm Recommended bolt torque (N-m) 50 to [0.71] , [0.94] Questions? Contact us at either , Specifications subject to change.

141 Model 103 Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the model code and the range code. For example: BL805 LL Model code code Order codes BL805 Model 103 load cell Low cost 100 kg to kg range ±0.02 % accuracy Specifications Performance Load ranges 3 100, 200, 300, 500, 1000, 2000, 3000, 5000, kg ±0.02 % full scale 2 mv/v (nominal) ±0.02 % full scale (30 minutes) Accuracy Output Creep (max.) Environmental Temperature, operating Temperature, compensated Temperature effect, zero ±0.02 % full scale/10 C Temperature effect, span ±0.02 % full scale/10 C -30 C to 70 C [-22 F to 158 F] -20 C to 55 C [-4 F to 130 F] Strain gage type Bonded foil Excitation (calibration) 10 Vdc to 12 Vdc Excitation (max.) 15 Vdc Insulation resistance >5000 mohm Bridge resistance (tolerance) Input resistance 400 ohm ±10 ohm (nominal) Output resistance 352 ohm ±2 ohm (nominal) Zero balance (tolerance) ±1 % full scale termination (std) 100 kg to 300 kg 3 m flying leads 1000 kg to 5000 kg 5 m flying leads kg 8 m flying leads Mechanical Maximum allowable load 150 % full scale 1 Material Nickel plated alloy steel Deflection < 1,5 mm Mounting dimensions and characteristics LH LL LM LN Cable Red Notes 100 kg 250 kg 300 kg 500 kg Wiring codes Black Green White Large black (+) supply (-) supply (+) output (-) output shield 1. Allowable maximum loads maximum load to be applied without damage Without damage - loading to this level will not cause excessive zero shift of performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. 3. This unit is calibrated to Metric (non-imperial) units. Typical system diagram LQ LS LU LW 1000 kg 2000 kg 5000 kg kg Load (kg) A mm B mm C mm D mm E mm F mm G mm H mm L mm M mm Recommended bolt torque (N-m) 100 to [5.31] 36 [1.42] 26 [1.02] 18 [0.71] 75 [2.95] 25 [1.0] 32 [1.26] 58 [2.28] 11,5 [0.45] 11,5 [0.45] to [5.31] 38 [1.5] 30 [1.18] 18 [0.71] 75 [2.95] 25 [1.0] 34 [1.34] 58 [2.28] 13,5 [0.53] 13,5 [0.53] to [6.69] 48 [1.89] 38 [1.5] 20 [0.79] 85 [3.35] 50 [2.0] 39 [1.54] 79 [3.11] 18 [0.71] 18,5 [0.73] [10.35] 60 [2.36] 60 [2.36] 30 [1.18] 118 [4.65] 90 [3.54] 52 [2.05] 134 [5.28] 26 [1.02] 26 [1.02] 860 Specifications subject to change. Questions? Contact us at either , 283

142 Output Input Serial Number SETUP LOAD CELLS Model 3663 and Pedal Pressure Load Cell How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code and the desired load range in lb. For example: Order code (lb) Order codes 3663 Model 3663 pedal pressure load cell, with band Model 3663 pedal pressure load cell Model 3663 code BN 50 lb BR CL CP 100 lb 200 lb 300 lb Low off-center loading error Easy mounting Rugged load surface Typical system diagram In-Line Amplifiers (Used with unamplified units only) Amplifier Output Universal In-Line Amplifiers UV +/-5 VDC UV-10 +/-10 VDC UBP 0 +/-5 VDC U3W 4-20mA (3 wire) U2W 4-20mA (2 wire) DIN rail Mount In-Line Amplifiers DV /- 5 VDC (3 wire) DA mA (3 wire) DV10 0 +/- 10 VDC (3 wire) MODEL 3663 Model Honeywell In-Line Amplifier Customer Supplied Chart Recorder Alarm Panel Data Acquisition Computer PLC Power Supply Display Units SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH PSD Specifications Performance Load range 50, 100, 200, 300 lb Non-linearity ±0.25 % of rated output Hysteresis ±0.1 % of rated output Repeatability ±0.1 % of rated output rated capacity 2 mv/v (nominal) Operation Tension/compression Resolution Infinite Standard calibration Tension (+) and compression (-) Environmental Temperature, operating -54 C to 93 C [-65 F to 200 F] Temperature, compensated 21 C to 77 C [70 F to 170 F] Temperature effect, zero ±0.003 % of rated output/ F Temperature effect, output ±0.003 % of reading/ F Strain gage type Foil Excitation (maximum) 20 Vdc or Vac RMS Insulation resistance > Vdc Bridge resistance (tolerance) 350 ohm Zero balance ±2.0 % termination PT06W-12-10P Mechanical Static overload capacity 150 % of nominal capacity Safe overload rating 150 % of nominal capacity Mounting dimensions and characteristics lb. L1 L2 L3 L4 1 3/32 VALUE CLEAR CHAN TARE UP DOWN ENTER EXIT Mating Connectors & Cables 023-LW LF Mating Connector XX** Mating connector & 4 conductor cable BRAKE PEDAL PAD 1 5/8 2.0 DIA. TWO ADJUSTABLE CLAMPS FURNISHED ** XX represents length in feet 20ft maximum 4 CONDUCTOR CABLE- For reference only RECEP. PT06W-12-10P 284 Questions? Contact us at either , Specifications subject to change.

143 Output Input Serial Number SETUP LOAD CELLS Model 3419 Seat Belt Load Cell Small size Installs without threading Low sensitivity to belt thickness change Typical system diagram In-Line Amplifiers (Used with unamplified units only) Amplifier Output Universal In-Line Amplifiers UV +/-5 VDC UV-10 +/-10 VDC UBP 0 +/-5 VDC U3W 4-20mA (3 wire) U2W 4-20mA (2 wire) DIN rail Mount In-Line Amplifiers DV /- 5 VDC (3 wire) DA mA (3 wire) DV10 0 +/- 10 VDC (3 wire) MODEL 3419 Honeywell In-Line Amplifier Display Units Customer Supplied Chart Recorder Alarm Panel Data Acquisition Computer PLC Power Supply SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH PSD Mating Connectors & Cables lb. L1 L2 L3 L4 VALUE CLEAR CHAN TARE UP DOWN ENTER EXIT 023-LW LF Mating Connector XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal) XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal) XX* Mating connector & 6 conductor cable (for connection to instrument 7541) XX** Mating connector & 4 conductor cable (for connection to instrument 7541) How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code and the desired load range in lb. For example: Order code Order codes (lb) 3419 Model 3419 seat belt load cell Specifications Performance Load range 3500 lb Non-linearity ±2 % of rated output Hysteresis ±4 % of rated output Repeatability ±1.0 % of rated output rated capacity 2 mv/v (nominal) Operation Tension/compression Resolution Infinite Standard calibration Tension (+) and compression (-) Environmental Temperature, operating -54 C to 93 C [-65 F to 200 F] Temperature, compensated 21 C to 77 C [70 F to 170 F] Temperature effect, zero ±0.003 % of rated output/ F Temperature effect, output ±0.003 % of reading/ F Strain gage type Foil Excitation (maximum) 20 Vdc or Vac RMS Insulation resistance > Vdc Bridge resistance (tolerance) 350 ohm Zero balance ±2.0 % termination 6 ft of four-conductor cable Mechanical Static overload capacity 150 % of nominal capacity Weight 8 oz Band thickness 2,54 mm [0.10 in] Band width 50,8 mm [2.0 in] Wiring codes Wire Red Black Green White Mounting dimensions and characteristics 1.0 (+) excitation (-) excitation (+) output (-) output /32 6 FT 4 CONDUCTOR CABLE PIGTAILS * XX represents length in feet 100ft maximum ** XX represents length in feet 20ft maximum HINGE POINT FOR BELT INSTALLATION & REMOVAL REMOVABLE PIN IS REINSERTED BEFORE CLOSING 0.10 MAX BELT THICKNESS 2.0 For reference only Specifications subject to change. Questions? Contact us at either , 285

144 Output Input Serial Number SETUP LOAD CELLS Model 6443 X-Y Force Sensor Measures engine mount force components Measures radial two component bearing force loads Measures tire radial and side loads Wiring codes Wire Red Black Green White (+) excitation (-) excitation (+) output (-) output Typical system diagram In-Line Amplifiers (Used with unamplified units only) Amplifier Output Universal In-Line Amplifiers UV +/-5 VDC UV-10 +/-10 VDC UBP 0 +/-5 VDC U3W 4-20mA (3 wire) U2W 4-20mA (2 wire) DIN rail Mount In-Line Amplifiers DV /- 5 VDC (3 wire) DA mA (3 wire) DV10 0 +/- 10 VDC (3 wire) MODEL X-Y FORCE Honeywell In-Line Amplifier Customer Supplied Chart Recorder Alarm Panel Data Acquisition Computer PLC Power Supply Display Units SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH PSD OR Mating Connectors & Cables lb. L1 L2 L3 L4 VALUE CLEAR CHAN TARE UP DOWN ENTER EXIT How to order: (Quick-ship range/option combinations available. See Web site.) Combine the order code and the desired load range in lb. For example: Order code Order codes (lb) 6443 Model 6443 X-Y force sensor, X = 1000, Y = Model X-Y force sensor, X = 2000, Y = Model X-Y force sensor, X = 1500, Y = 500 Specifications Performance Load range Order code Capacity (lb) - X, radial Capacity (lb) - Y, side Non-linearity ±0.1 % of rated output Hysteresis ±0.1 % of rated output Repeatability ±0.05 % of rated output rated capacity 2 mv/v ±0.25 % (nominal) Operation Tension/compression Resolution Infinite Standard calibration Tension (+) and compression (-) 1 Environmental Temperature, operating -54 C to 93 C [-65 F to 200 F] Temperature, compensated 21 C to 77 C [70 F to 170 F] Temperature effect, zero ±0.002 % of rated output/ F Temperature effect, output ±0.002 % of reading/ F Strain gage type Foil Excitation (maximum) 20 Vdc or Vac RMS Insulation resistance > Vdc Bridge resistance (tolerance) 350 ohm Crosstalk 1 % of full scale Zero balance ±1.0 % termination MS-3102E-14S-5P (2) Mechanical Safe overload capacity 150 % of rated capacity Material Carbon steel Mounting dimensions and characteristics 13/32 4 HOLES EQUALLY SPACED RECEP. MS-3102E-14S-5P (2) 2-21/ LW13621 Mating connector XX* Mating connector and six conductor cable (unamplified unit with sense leads but not shunt cal) XX** Mating connector (MS - 5 pin) and four conductor cable (unamplified sensor without sense leads) XX** Mating connector ( MS 5 pin ) & 6 conductor cable for connection to XX** Mating connector ( MS 5 pin ) & 4 conductor cable for connection to 7541 * XX represents length in feet 100ft maximum ** XX represents length in feet 20ft maximum 2-1/16 TYP. 7.0 DIA DIA. B.C. For reference only 1 Standard calibration for tension/compression load cells is in tension only DIA. BOTH ENDS 7/64 MAX. BRG 0.75 BORE 1/ Questions? Contact us at either , Specifications subject to change.

Model RGH. Rod End In-line Compression/Tension Load Cell DESCRIPTION FEATURES

Model RGH. Rod End In-line Compression/Tension Load Cell DESCRIPTION FEATURES Rod End In-line Compression/Tension Load Cell DESCRIPTION The Model RGH In-Line load cells are high quality, stainless steel, rugged load cells capable of withstanding significant off-axis loads, making

More information

Model 41E. Precision Low Profile Load Cell DESCRIPTION FEATURES

Model 41E. Precision Low Profile Load Cell DESCRIPTION FEATURES Precision Low Profile Load Cell DESCRIPTION Model 41E is a low profile pancake type load cells. These bonded foil, strain gage load cells are engineered to measure loads from 20 N to 200 kn. The tension/

More information

Model RH. Rod End In-line Tension Load Cell DESCRIPTION FEATURES

Model RH. Rod End In-line Tension Load Cell DESCRIPTION FEATURES Rod End In-line Tension Load Cell DESCRIPTION Model RH, with male and female threads, is a high output rod end load cell designed to be mounted inline to the load axis to measure tension. The outputs for

More information

Model UG. Ultra Precision Universal Canister Load Cell DESCRIPTION FEATURES

Model UG. Ultra Precision Universal Canister Load Cell DESCRIPTION FEATURES Ultra Precision Universal Canister Load Cell DESCRIPTION Model UG Ultra Precision Universal load cell achieves scale quality and performance standards.the Model UG achieves ±0.03 % non-linearity with very

More information

Model A-5. Mid Range Wet/Wet Differential Pressure Transducer. A-5, Datenblatt Seite 1 DESCRIPTION FEATURES

Model A-5. Mid Range Wet/Wet Differential Pressure Transducer. A-5, Datenblatt Seite 1 DESCRIPTION FEATURES A-5, Datenblatt Seite 1 Model A-5 Mid Range Wet/Wet Differential Pressure Transducer DESCRIPTION Model A-5 mid-range Wet/Wet Differential is a bonded foil strain gage transducers designed to accept fluid

More information

Model Tension/Compression Pancake Load Cell DESCRIPTION FEATURES

Model Tension/Compression Pancake Load Cell DESCRIPTION FEATURES Model 3173 Tension/Compression Pancake Load Cell DESCRIPTION The Model 3173 covers the lower capacity ranges of 200 pounds force to 3000 pounds force, while exhibiting the high performance characteristics

More information

SETUP SUNSTAR 传感与控制 Model 3173 PERFORMANCE SPECIFICATIONS Load range 1 Accuracy 0.07 % Non-linearity Hysteresis Repeatabilit

SETUP SUNSTAR 传感与控制   Model 3173 PERFORMANCE SPECIFICATIONS Load range 1 Accuracy 0.07 % Non-linearity Hysteresis Repeatabilit Model 3173 DESCRIPTION The Model 3173 covers the lower capacity ranges of 200 pounds force to 3000 pounds force, while exhibiting the high performance characteristics of stiffness and accuracy. These load

More information

Models Tension/Compression Pancake Load Cell Model 3174 with tension base DESCRIPTION FEATURES

Models Tension/Compression Pancake Load Cell Model 3174 with tension base DESCRIPTION FEATURES Models 3174-3176 Model 3174 Model 3174 with tension base DESCRIPTION Models 3174, 3175, and 3176 are fatigue-resistant, low-profile tension and compression load cells that are well suited to materials

More information

Pressure Transducer FP2000

Pressure Transducer FP2000 Pressure Transducer FP2000 Datasheet FPG FPA FPB FPV (Series FP2000) Pressure Transducers for Gauge, Absolute, Barometric and Vacuum Pressure Measurement from 0... 35 mbar up to 0... 700 bar Pressure Types:

More information

XPC10 High temperature miniature pressure sensor

XPC10 High temperature miniature pressure sensor Absolute, sealed and gauge ranges 10 to 500 bar [150 to 7 500 psi] High temp. operation from -40 up to 220 ºC [-40 to 428 F] Stainless steel construction Amplified output available For static and dynamic

More information

U10M. Force Transducer. Special features. Data sheet. Mounting dimensions of the connection variants in mm [inch]

U10M. Force Transducer. Special features. Data sheet. Mounting dimensions of the connection variants in mm [inch] U10M Force Transducer Special features - Precise and robust tensile/compressive force transducer for static and dynamic measurement tasks - High lateral force and bending moment stability, the effect of

More information

Sensor Datasheet Collection

Sensor Datasheet Collection ISO 9001 REGISTERED Specials are Our Standard Sensor Datasheet Collection CONTENTS HR-DRO: HIGH RESOLUTION DIGITAL READOUT 3 THE RELS FAMILY: ROD-END LOAD SENSORS 4-15 S-RELS SERIES: STANDARD ROD-END LOAD

More information

Model LBS Miniature Compression Load Button

Model LBS Miniature Compression Load Button Model LBS Miniature Compression Load Button Why the Interface model LBS Miniature Compression Load Button is the best in class: Temperature compensated Integral load button Small diameter From." height

More information

Miniature pressure sensor

Miniature pressure sensor SPECIFICATIONS Ranges 0.5 to 350 bar [7 psi to 5 000 psi] Absolute, sealed and gauge Titanium construction For static and dynamic applications Linearity up to ±0.25% FS The XP5 serie is designed in titanium

More information

Torque Sensor Accessories and Services

Torque Sensor Accessories and Services ------------------- Torque Sensor Accessories and Services Highlights Strain gage signal conditioners Cable assemblies Speed sensors Shunt calibration modules and thermocouples Calibration services PCB

More information

Load Cell Accessories and Services

Load Cell Accessories and Services Load Cell Accessories and Services Highlights Strain gage signal conditioners Cable assemblies Mounting accessories Calibration services PCB Piezotronics, Inc. Toll-Free in USA 888-684-0004 716-684-0001

More information

K3D60a ±100N. Description. The K3D60a three-axis sensor is suitable for measuring force on three mutually perpendicular axes.

K3D60a ±100N. Description. The K3D60a three-axis sensor is suitable for measuring force on three mutually perpendicular axes. K3D60a ±100N Description The K3D60a three-axis sensor is suitable for measuring force on three mutually perpendicular axes. The new 3-axis sensor K3D60a is a further development of the series K3D60 and

More information

MICROMACHINED SILICON MODULAR PRESSURE SENSOR

MICROMACHINED SILICON MODULAR PRESSURE SENSOR MICROMACHINED SILICON MODULAR PRESSURE SENSOR Configurable High Accuracy High Temperature Performance For Industrial, Test and Measurement, and Aerospace Applications Low Pressure from 10 in-h 2 O to 2.5

More information

Type PB Load Cell. Approvals OIML approval to C3 (Y = 7 500; Y = for 375 kg capacity)

Type PB Load Cell. Approvals OIML approval to C3 (Y = 7 500; Y = for 375 kg capacity) Type PB Load Cell IP65 Product Description The type PB is a very low profile planar beam load cell. Its unique Flintec design allows for an extremely low scale construction. Using 3 or 4 type PB load cells

More information

mv/v Output MELT PRESSURE TRANSMITTERS I3 SERIES TECHNICAL SPECIFICATIONS

mv/v Output MELT PRESSURE TRANSMITTERS I3 SERIES TECHNICAL SPECIFICATIONS MELT PRESSURE TRANSMITTERS I3 SERIES mv/v Output D The IMPACT series of Gefran, are pressure transmitters, without transmission fluid, for using in High temperature environment (350 C). Medium pressure

More information

Aero Support Ltd, 70 Weydon Hill Road, Farnham, Surrey, GU9 8NY, U.K.

Aero Support Ltd, 70 Weydon Hill Road, Farnham, Surrey, GU9 8NY, U.K. 4-170 Piezoelectric Accelerometer The CEC 4-170 accelerometer is a self-generating, piezoelectric accelerometer designed for medium temperature vibration measurement applications. This instrument provides

More information

U15. Force transducer. Special features. Data sheet. Installed dimensions of connection variants

U15. Force transducer. Special features. Data sheet. Installed dimensions of connection variants U15 Force transducer Special features - Tensile/compressive force transducer - Nominal (rated) forces 2.5 kn to 2.5 MN - lass 0.5 to ISO 376 in force measurement range between 10% and 100% of the nominal

More information

Force and strain sensors.

Force and strain sensors. Force and strain sensors. Measure. Test. Control. Edition 2016 Force and strain sensors by Baumer combine tried and tested technology and sophisticated innovations. 1 Contents. Introduction 1 Product key

More information

C10. Data sheet. Force transducer. Special features. B de

C10. Data sheet. Force transducer. Special features. B de C10 Force transducer Data sheet Special features Force transducer for static and dynamic applications Made of non-rusting materials Precise (accuracy class from 0.03) Numerous options (double bridge, TEDS,

More information

TORQUE. Quick-ship program - torque

TORQUE. Quick-ship program - torque Torque Honeywell Sensing and Control s torque sensors feature both reaction (non-rotating) and rotary torque sensors that utilize bonded strain gage technology. The rotary torque capability offers both

More information

Heavy Duty Pressure Transducers. PX2 Series 1 bar to 46 bar 100 kpa to 4.6 MPa 15 psi to 667 psi. Datasheet

Heavy Duty Pressure Transducers. PX2 Series 1 bar to 46 bar 100 kpa to 4.6 MPa 15 psi to 667 psi. Datasheet PX2 Series bar to 46 bar 00 kpa to 4.6 MPa 5 psi to 667 psi Datasheet Table. Electrical Specifications Characteristic Ratiometric Regulated Transfer Function Order Code (See Figure 5.) AA AB AC AD CH BC

More information

Technical data Model F1301 F13C1 ATEX/IECEX 2) F13C1 (Option) Nominal load F nom 10 / 20 / 30 / 50 / 100 / 200 kn 10 / 20 / 30 / 50 / 100 / 200 kn 10

Technical data Model F1301 F13C1 ATEX/IECEX 2) F13C1 (Option) Nominal load F nom 10 / 20 / 30 / 50 / 100 / 200 kn 10 / 20 / 30 / 50 / 100 / 200 kn 10 Compression force transducer with Thin-film sensor Accuracy: 1 % Output signal: 4...20 ma; 2-wire, 0...10 VDC; 3-wire Optional Optional ATEX/IECEX II 2G Ex ib IIC T4/T3 for SIL3-Applications with 2-channel

More information

U5300 Industrial Pressure Transducer

U5300 Industrial Pressure Transducer Superior Accuracy and Total Error Band Instrument Grade CE Compliant Compact Variety of Pressure Ports and Electrical Configurations Optional Stainless Steel Snubber Weatherproof Gage, Sealed, Absolute,

More information

vibrati vibration solutions by sensor type Measurement Specialties brings more than twenty years of

vibrati vibration solutions by sensor type Measurement Specialties brings more than twenty years of vibration solutions by sensor type Measurement Specialties brings more than twenty years of vibrati experience in the design and manufacture of s and gyros based on our proprietary Micro-ElectroMechanical

More information

Force and weight measuring instruments

Force and weight measuring instruments JJ Force sensors and load cells JJ Measurement amplifiers JJ Mechanical and electronic accessories JJ Combination units JJ Force calibration systems Force and weight measuring instruments DS_Force_and_weight_measuring_instruments

More information

XP5 Miniature pressure sensor

XP5 Miniature pressure sensor Absolute, sealed and gauge ranges 1 to 350 [15 psi to 5 000 psi] Titanium construction Amplified output available For static and dynamic applications Linearity up to ±0.25% FSO DESCRIPTION The XP5 miniature

More information

RG Connector (Molded Mating Extension Cable Required) A H B G. MS Connector (Mating Connector: P/N ; MS3116F-12-10S or Extension Cable)

RG Connector (Molded Mating Extension Cable Required) A H B G. MS Connector (Mating Connector: P/N ; MS3116F-12-10S or Extension Cable) T E M P O S O N I C S L S E R I E S INSTALLATION A N A L O G O U T P U T 550570 B W I R I N G - A N A L O G O U T P U T S RG Connector: (Voltage or Current Output) 1 Gray 0 to 10 Vdc, 4 to 20 ma, or 0

More information

M5200 Industrial Pressure Transducer

M5200 Industrial Pressure Transducer SPECIFICATIONS Wide Temperature Range Compact Variety of Pressure Ports and Electrical Configurations Optional Stainless Steel Snubber CE Compliant and Weatherproof Gage, Sealed, Compound The M5200 pressure

More information

WS12EX Position Sensor with Analog output Dust explosion-proof

WS12EX Position Sensor with Analog output Dust explosion-proof Sensor for Hostile Environments Class IP67 Measurement Range: 0... 100 mm to 0... 3000 mm With Analog Output Dust Ex proof, category 3, zone 22 II 3D EEx T80 C IP67 Specifications Outputs Material Resolution

More information

CSG110 Strain Gauge Universal Amplifier

CSG110 Strain Gauge Universal Amplifier Quick Start Guide CSG110 Strain Gauge Universal Amplifier Sensor Solutions Source Load Torque Pressure Multi-Axis Calibration Instruments Software www.futek.com Getting Help TECHNICAL SUPPORT For more

More information

Signal Conditioning Amplifier

Signal Conditioning Amplifier 2300 System Micro-Measurements FEATURES Accepts all strain gage inputs (foil and piezoresistive), potentiometers, DCDT s, etc Selectable bridge excitation, 0.7 to 15 VDC (11 steps), plus 0.2 to 7 VDC continuously

More information

XXXX e. X d.. X X X a

XXXX e. X d.. X X X a The Heavy uty incremental encoder type 0H boasts a high degree of ruggedness in a very compact design. Its special construction makes it perfect for all applications in very harsh environments. / RoHS

More information

P125 High pressure sensor

P125 High pressure sensor Ranges from 2000 to 7000 bar Stainless steel Robust for Fatigue testing High level output in option For static and dynamic applications Linearity up to ±0.3% F.S. DESCRIPTION The P125 is a high pressure

More information

Tel: (949) Fax: (949) IAA100 Product Manual

Tel: (949) Fax: (949) IAA100 Product Manual IAA100 Product Manual Table of Contents Default Settings... 3 Connections... 3 Standard Span & Zero Adjustment... 4 Shunt Readings... 5 Digitally Controlled Remote Shunt... 5 Switch Configurations... 6

More information

Modus M Series. General Eastern Differential Pressure Transmitters. GE Sensing

Modus M Series. General Eastern Differential Pressure Transmitters. GE Sensing The Modus M Series family of differential pressure transmitters measure low pressures, and feature a variety of analog signal outputs with low power consumption. A wide selection of standard pressure ranges

More information

ED701 General Industry Pressure Transmitter

ED701 General Industry Pressure Transmitter ED701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

AC AC AC

AC AC AC AC104.01-10 AC104.01-100 AC104.01-500 Description The hermetic sealed industrial piezoelectric accelerometer model 104 is design to monitor the vibration in harsh industrial environment. It uses the industry

More information

Model FP2000. Configurable Pressure Transducer DESCRIPTION FEATURES

Model FP2000. Configurable Pressure Transducer DESCRIPTION FEATURES Model P2000 onfigurable Pressure Transducer SIPTION The P2000 series is a configurable pressure transducer which allows the customer to select the configuration which best fits the needs of the application.

More information

Force and weight measuring instruments

Force and weight measuring instruments JJ Force sensors and load cells JJ Hanging scales JJ Sensors for proof load testing JJ Water filled bags Force and weight measuring instruments DS_Force_and_weight_measuring_instruments 05/2016 97 Force

More information

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5) Pressure OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5) WIKA data sheet PE 81.65 for further approvals see page 11 Applications Hydraulics and pneumatics Pumps and compressors

More information

Sherborne Sensors is an ISO9001 and AS9100 certified global leader in the design, development, manufacture and supply of high precision

Sherborne Sensors is an ISO9001 and AS9100 certified global leader in the design, development, manufacture and supply of high precision Sherborne Sensors is an ISO9001 and AS9100 certified global leader in the design, development, manufacture and supply of high precision inclinometers, accelerometers, force transducers, load cells, instrumentation

More information

GS Strain gauge reader/ transmitter. GS series of wireless industrial sensors. Features: General Description: Applications:

GS Strain gauge reader/ transmitter. GS series of wireless industrial sensors. Features: General Description: Applications: GS series of wireless industrial sensors Strain gauge reader/ transmitter Features: Input: strain gauge Wheatstone bridge: 300ohms to 10kohms. Typical: 1000 ohms. Standard input range: up to 2mV/V full

More information

TPFADA FLUSH DIAPHRAGM PRESSURE TRANSMITTER WITH DIGITAL AUTOZERO & SPAN

TPFADA FLUSH DIAPHRAGM PRESSURE TRANSMITTER WITH DIGITAL AUTOZERO & SPAN TECHNICAL DATA TPFADA FLUSH DIAPHRAGM PRESSURE TRANSMITTER WITH DIGITAL AUTOZERO & SPAN Main features Ranges: from 0...10 to 0...1000 bar Output signal 4...0mA -wires / 0.1...5.1Vdc / 0.1...10.1Vdc / 0...5Vdc

More information

ID/HX-EP SERIES DIGITAL OUTPUT

ID/HX-EP SERIES DIGITAL OUTPUT ID/HX-EP SERIES DIGITAL OUTPUT Utilizing an incremental encoder as the sensor, the ID/HX-EP Series position transducer provides a two channel square wave current sinking output signal in quadrature. The

More information

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R O P E R AT I O N M A N U A L Model 4800 L O A D C E L L S U M M I N G T R A N S M I T T E R CALEX Manufacturing Company, Inc. Concord, California 94520 Ph: 925/687-4411 800/542-3355 Fax: 925/687-3333 http://www.calex.com

More information

Miniature silicon-on-insulator pressure transducer for absolute pressure measurement at 260 C

Miniature silicon-on-insulator pressure transducer for absolute pressure measurement at 260 C Miniature silicon-on-insulator pressure transducer for absolute pressure measurement at 260 C PMiniature silicon-on-insulator pressure transducer for absolute pressure measurement at 260 C Abstract A miniature,

More information

Model 3A Series 3-Axis Load Cell

Model 3A Series 3-Axis Load Cell Model 3A Series 3-Axis Load Cell 3-Axis Fx Fy Fz; Independent Bridges 20N to 500kN Force Range Compact Size Low Crosstalk Temperature Compensated Accessories Model 3A60A BSC4A 4-Channel Analog Amplifier

More information

4-20 ma Vibration Transmitter, Top connector

4-20 ma Vibration Transmitter, Top connector 4-20 ma Vibration Transmitter, Top connector Main Characteristics Atex Approved for zone 0, 1, 2. Can monitor machine as low as 180 RPM. Annular shear mode (better than obsolete compression design) Velocity

More information

TECHNICAL MANUAL. SERIES AP5202 DC Strain Gage In-Line Amplifier ISO 9001/AS9100

TECHNICAL MANUAL. SERIES AP5202 DC Strain Gage In-Line Amplifier ISO 9001/AS9100 TECHNICAL MANUAL SERIES AP5202 DC Strain Gage In-Line Amplifier ISO 9001/AS9100 Due to the nature of technology, changes are inevitable. For latest technical specifications, see our website. Copyright

More information

HX-EP SERIES DIGITAL OUTPUT

HX-EP SERIES DIGITAL OUTPUT HX-EP SERIES DIGITAL OUTPUT Utilizing an incremental encoder as the sensor, the UniMeasure HX-EP series position transducer provides a two channel square wave current sinking output signal in quadrature.

More information

Model 3A Series 3-Axis Load Cell

Model 3A Series 3-Axis Load Cell Model 3A Series 3-Axis Load Cell 3-Axis Fx Fy Fz; Independent Bridges 20N to 500kN Force Range Compact Size Low Crosstalk Temperature Compensated Accessories BSC4A 4-Channel Analog Amplifier BSC4D 4-Channel

More information

R30D RVDTs DC-Operated Rotary Variable Differential Transformers

R30D RVDTs DC-Operated Rotary Variable Differential Transformers R30D RVDTs DC-Operated Rotary Variable Differential Transformers RVDTs incorporate a proprietary noncontact design that dramatically improves long term reliability when compared to other traditional rotary

More information

Rotary Position Technology Incremental Encoders

Rotary Position Technology Incremental Encoders -40 to 80 C Temperature Shock/vibration resistant Short-circuit protected Reverse polarity protection High rotational speed Rugged Balanced, stainless-steel clamping rings, special bearing-shaft connection

More information

Miniature silicon-on-insulator pressure transducer for absolute pressure measurement at 260 C TP 301

Miniature silicon-on-insulator pressure transducer for absolute pressure measurement at 260 C TP 301 Miniature silicon-on-insulator pressure transducer for absolute pressure measurement at 260 C TP 301 Model 8540 miniature pressure transducer for absolute pressure measurement at 260 C Abstract A miniature,

More information

PRESSURE TRANSDUCERS. Specifications. Integral Connector Versions

PRESSURE TRANSDUCERS. Specifications. Integral Connector Versions GMS OMPLINT 00 Series and 00 Heavy Duty Series ompact OM Pressure Transmitters xceptional Long Term Stability 0-00 psi to 0-0,000 psi Ranges (0- bar to 0-,00 bar) High Proof Pressures with ll Stainless

More information

Series T. General Eastern Differential Pressure Transmitters. GE Sensing. Description

Series T. General Eastern Differential Pressure Transmitters. GE Sensing. Description Description The Series T family of differential pressure transmitters measure low pressures and feature low power consumption and a variety of analog signal outputs. A wide selection of standard pressure

More information

Torque Sensor. Torque. with Dual-Range-Option. Type 4503A...

Torque Sensor. Torque. with Dual-Range-Option. Type 4503A... Torque Torque Sensor with Dual-Range-Option Type 4503A... Type 4503A... torque sensors with built-in speed sensor operate on the strain gage principle. An integral, digital measurement conditioning system

More information

XXXX e. X d.. X X X a

XXXX e. X d.. X X X a The Heavy Duty incremental encoder type 0H boasts a high degree of ruggedness in a very compact design. Its special construction makes it perfect for all applications in very harsh environments. / RoHS

More information

Non-Submersible Industrial Pressure Transducer

Non-Submersible Industrial Pressure Transducer Non-Submersible Industrial Pressure Transducer KPSI Transducers Series 27, 28, 30 FEATURES Custom Pressure Ranges up to 2000 (13,790 kpa) Accuracy to ±0.10% FS Analog Outputs of 4-20 ma or VDC Welded 316

More information

ELPF Load Cell DESCRIPTION

ELPF Load Cell DESCRIPTION Compact Tension/Compression Design 10 500 lbf High Level and mv Output High Stability Industry Standard Packing Resists Off Axis Load Components Full NIST Traceable 11 Point Calibration Shielded Teflon

More information

U2B. Force Transducer. Special features. Data sheet

U2B. Force Transducer. Special features. Data sheet U2B Force Transducer Special features - Tensile/compressive force transducer - Non rusting, degree of protection IP67 - Can be configured with different cable lengths, plug fitting and TEDS on request

More information

T40FH. Torque flange. Special features. Data sheet

T40FH. Torque flange. Special features. Data sheet T40FH Torque flange Special features - Nominal (rated) torques: 100kNm, 125kNm, 150kNm, 200kNm, 250kNm, 300kNm - Nominal (rated) rotational speed of 2000 rpm up to 3000 rpm - Compact design - Version for

More information

Rotary Measurement Technology Incremental Encoders

Rotary Measurement Technology Incremental Encoders -20 to 60 C Temperature Shock/vibration resistant Short-circuit protection Reverse polarity protection High rotational speed Rugged Balanced, stainless-steel clamping rings, special bearing-shaft connection

More information

Force and strain sensors. Measure. Test. Control.

Force and strain sensors. Measure. Test. Control. Force and strain sensors. Measure. Test. Control. Force and strain sensors by Baumer combine tried and tested technology and sophisticated innovations. 1 Contents. Introduction 1 Force and strain sensors

More information

SRS SEALED ROTARY SENSORS

SRS SEALED ROTARY SENSORS SRS SEALED ROTARY SENSORS Innovation In Motion INNOVATION IN MOTION Penny+Giles SRS280 sealed rotary sensors and SRS880 submersible rotary sensors have been specially developed to provide maximum performance

More information

U2B. Data sheet. Force Transducer. Special features. B en

U2B. Data sheet. Force Transducer. Special features. B en U2B Force Transducer Special features Data sheet Tensile/compressive force transducer Non-rusting, degree of protection IP67 Can be configured with different cable lengths, plug fitting and TEDS on request

More information

Making Basic Strain Measurements

Making Basic Strain Measurements IOtech Product Marketing Specialist steve.radecky@iotech.com Making Basic Strain Measurements using 24-Bit IOtech Hardware INTRODUCTION Strain gages are sensing devices used in a variety of physical test

More information

TECHNICAL MANUAL. SERIES AP5103 DIN-Rail DC Strain Gage Conditioner ISO 9001/AS9100

TECHNICAL MANUAL. SERIES AP5103 DIN-Rail DC Strain Gage Conditioner ISO 9001/AS9100 TECHNICAL MANUAL SERIES AP5103 DIN-Rail DC Strain Gage Conditioner ISO 9001/AS9100 Due to the nature of technology, changes are inevitable. For latest technical specifications, see our website. Copyright

More information

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5) Electronic pressure measurement OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5) WIKA data sheet PE 81.65 Applications Hydraulics and pneumatics Pumps and compressors

More information

Load Cells Shear beam load cells SIWAREX WL230 SB-S SA

Load Cells Shear beam load cells SIWAREX WL230 SB-S SA oad cell Overview Combined error comb Repeatability v ±0.0% C n ±0.0% C n The shear beam load cell is particularly suitable for implementation in container, overhead rail conveyor and platform scales.

More information

M5800 Pressure Transducer with Rotatable Display

M5800 Pressure Transducer with Rotatable Display Pressure Transducer with Rotatable Display SPECIFICATIONS Wide Temperature Range Compact Variety of Pressure Ports and customized Electrical Configurations Optional Stainless Steel Snubber CE Compliant

More information

Cable transducer Analog output / redundant Measuring length absolute up to 5 m

Cable transducer Analog output / redundant Measuring length absolute up to 5 m Features Magnetic sensing method Resolution: 12 bit Interface analog 0...10 V / 0.. V /...20 ma Measuring length up to m Removable stickers for water outlet Teach inputs Extremely light thanks to housing

More information

Temposonics. Magnetostrictive Linear Position Sensors. GB-M / GB-T SSI Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. GB-M / GB-T SSI Data Sheet Temposonics Magnetostrictive Linear Position Sensors GB-M / GB-T SSI Sensor element and electronics can be changed Flat & compact sensor electronics housing Electrical connection is freely rotatable MEASURING

More information

General Specification

General Specification 2001 Catalog General Specification WISE SENSOR INC. WISE SENSOR INC. C O N T E N T S Product guide for pressure measurement Product guide for level measurement Product guide for temperature measurement

More information

Weighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier

Weighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 Weighing System Evaluation Mounting DMS strain gauges (load cells), DMS amplifier

More information

Heavy Duty Pressure Transducers

Heavy Duty Pressure Transducers Installation Instructions for the Heavy Duty Pressure Transducers General Information Honeywell s PX3 Series Pressure Transducers use piezoresistive sensing technology with ASIC (Application Specific Integrated

More information

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM SYSTEM OVERVIEW Pollution monitoring of high voltage insulators in electrical power transmission and distribution systems, switchyards and substations is essential in order to minimise the risk of power

More information

Torque Sensor. Torque. Dual-Range Sensor with Brushless Transmission. Type 4503A...

Torque Sensor. Torque. Dual-Range Sensor with Brushless Transmission. Type 4503A... Torque Torque Sensor Dual-Range Sensor with Brushless Transmission Type 4503A... Type 4503A... torque sensors with built-in speed sensor operate on the strain gage principle. An integral, digital measurement

More information

T10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en

T10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en T10FS Torque Flange Data Sheet Special features Nominal (rated) torques: 100 NVm, 200 NVm, 500 NVm, 1 knvm, 2 knvm, 3 knvm, 5 knvm, 10 knvm Nominal speed from 12,000 rpm to 24,000 rpm Low rotor weights

More information

Vehicle & Component Durability Sensors Accelerometers, Load Cells, Force Sensors, and Signal Conditioners

Vehicle & Component Durability Sensors Accelerometers, Load Cells, Force Sensors, and Signal Conditioners WWW.PCB.COM Vehicle & Component Durability Sensors Accelerometers, Load Cells, Force Sensors, and Signal Conditioners Automotive Sensors Division Toll-Free in USA 888-684-0014 716-684-0001 www.pcb.com

More information

Load Cells Page Option Option

Load Cells Page Option Option Content: Load Cells Page Option Option Dynamometer, V-LINK 1 Wireless Remote Display, V-LINK 2 Mechanical Overload Switch 3 Static Line Tensiometer 4 Heavy Duty Tensiometer 5 ATEX Running Line Tensiometer

More information

M5200 Industrial Pressure Transducer

M5200 Industrial Pressure Transducer CE Compliant Wide Temperature Range Compact Variety of Pressure Ports and Electrical Configurations Optional Stainless Steel Snubber Weatherproof Gage, Sealed, Compound DESCRIPTION The M5200 pressure transducers

More information

Pressure measurement PBMR Fully welded pressure transmitter for railway applications

Pressure measurement PBMR Fully welded pressure transmitter for railway applications Fully welded pressure transmitter for railway Product highlights Ecellent accuracy and long term stability up to % FS Active temperature compensation over the entire operating temperature range Sensor

More information

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition Converter Connection 1-channel EEx ia IIC for 4-wire and 6-wire bridges Analogue output 0/4 ma... 20 ma or 4mA...-12mA Full bridge load cells and strain gauges circuit for resistance bridges up to 17 Ω

More information

Standard Sendix 5000 / 5020 (shaft / hollow shaft) Push-Pull / RS422 / Open collector. Robust performance. Many variants

Standard Sendix 5000 / 5020 (shaft / hollow shaft) Push-Pull / RS422 / Open collector. Robust performance. Many variants ue to their sturdy bearing construction in Safety-ock esign, the Sendix 5000 and 500 offer high resistance against vibration and installation errors. The rugged housing, high protection level of up to

More information

SM82-EZ-II-WX 8 SURFACE MOUNT WEATHERPROOF SPEAKER. Nominal Impedance. Sensitivity 2.83V/1M Sensitivity 1W/1M (2)

SM82-EZ-II-WX 8 SURFACE MOUNT WEATHERPROOF SPEAKER. Nominal Impedance. Sensitivity 2.83V/1M Sensitivity 1W/1M (2) Specifications: Nominal Impedance Impedance (min) Sensitivity db @ 2.83V/1M Sensitivity db @ 1W/1M (2) Frequency Response (± 3 db) Frequency Response (±10 db) Max. Program Power Max. Continuous Power RMS

More information

U9C. Data sheet. Force Transducer. Special features. B en

U9C. Data sheet. Force Transducer. Special features. B en U9C Force Transducer Data sheet Special features Tensile/compressive force transducer Accuracy class 0.2 Nominal (rated) forces 50 N 50 KN Non-rusting, protection class IP67 Configurable with different

More information

ph or ORP Transmitter

ph or ORP Transmitter ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes

More information

Phone: Fax: Web: -

Phone: Fax: Web:  - ue to their sturdy bearing construction in Safety-ock esign, the Sendix 5000 and 500 offer high resistance against vibration and installation errors. The rugged housing, high protection level of up to

More information

RoHS. High shaft load capacity. Shock / vibration resistant

RoHS. High shaft load capacity. Shock / vibration resistant Due to their sturdy bearing construction in Safety Lock Design, the Sendix 5000 and 5020 offer high resistance against vibration and installation errors. The rugged housing, high protection level of up

More information

Weighing Instruments

Weighing Instruments GHM Messtechnik GmbH Sales Center International Schloßstraße 6 88453 Erolzheim Germany Fon +49-7354-937233-0 Fax -88 www.ghm-messtechnik.de info@ghm-messtechnik.de Weighing Instruments System Evaluation

More information

U5300 Industrial Pressure Transducer

U5300 Industrial Pressure Transducer SPECIFICATIONS Superior Accuracy and Total Error Band Instrument Grade and Compact Variety of Pressure Ports and Electrical Configurations Optional Stainless Steel Snubber CE Compliant and Weatherproof

More information

Force and strain sensors. Measure. Test. Control. Edition 2016

Force and strain sensors. Measure. Test. Control. Edition 2016 Force and strain sensors. Measure. Test. Control. Edition 2016 Force and strain sensors by Baumer combine tried and tested technology and sophisticated innovations. 1 Contents. Introduction 1 Product key

More information

TECHNICAL DATASHEET #TDAX Universal Input, Single Output Valve Controller CAN (SAE J1939)

TECHNICAL DATASHEET #TDAX Universal Input, Single Output Valve Controller CAN (SAE J1939) Features: TECHNICAL DATASHEET #TDAX021610 Universal Input, Single Output Valve Controller CAN (SAE J1939) 1 universal signal input (voltage, current, resistive, PWM, frequency or digital) 1 output: proportional

More information

CONTENTS LOAD CELLS / FORCE TRANSDUCERS TR CM CU AM TC TU TH CC CT SB SH CB OC OD CIR CIR-D

CONTENTS LOAD CELLS / FORCE TRANSDUCERS TR CM CU AM TC TU TH CC CT SB SH CB OC OD CIR CIR-D CONTENTS LOAD CELLS / FORCE TRANSDUCERS TR CM CU AM TC TU TH CC CT SB SH CB OC OD CIR CIR-D 3 TR FORCE TRANSDUCER FOR MEASURING THE TENSION ON FIXED OR ROTATING SPINDLES Main features Range of measurement:

More information