Force and strain sensors.
|
|
- Allison McLaughlin
- 6 years ago
- Views:
Transcription
1 Force and strain sensors. Measure. Test. Control. Edition 2016
2 Force and strain sensors by Baumer combine tried and tested technology and sophisticated innovations.
3 1 Contents. Introduction 1 Product key 1.2 Summary Force and Strain Sensors 1.4 Load Cells DLRx 2 Product key 2.2 Summary Load Cells 2.3 Strain Rings DSRC 3 Product key 3.2 Summary Strain Rings 3.3 Strain Probes DSRH 4 Product key 4.2 Summary Strain Probes 4.3 Piezo Electric Sensors 8 Product key 8.2 Summary Force and Strain Sensors 8.3 Product key 8.8 Summary Cavity Pressure Sensors 8.9 Charge Amplifiers DACx 9 Product key 9.2 Summary Charge Amplifiers 9.3 Supplementary Informations 10 General 10.2 Glossary and Explanations 11 General 11.2 Strain Links DSRT 5 Product key 5.2 Summary Strain Links 5.3 Bridge Amplifiers DABx 6 Product key 6.2 Summary Bridge Amplifiers 6.3 Display Boxes DDBF 7 Product key 7.2 Summary Display Boxes
4 Force and strain sensors measuring testing and monitoring Our product range embraces the entire field of force and strain sensors to meet a wide range of requirements and specific applications. It includes every component of efficient sensors and intelligent evaluation and application systems. Baumer supplies a complete range of sensors from a single source universality that pays off. The question of the respective technology does not depend on the product range, but wholly and solely on the nature of the technical problem involved. Whether this calls for a bonded S/G, our patented press-fitted S/G or a high-resolution Piezo system, we are experts in all three. Sensors with S/G technology Strain gauges are used for measurements of physical values on structures, for example weight and strain. Strain measurement on tie bars and columns Strain measurement on platen and rigid structures Static and cyclic strain and force measurement 2x1/4 bridge or full bridge Bridge amplifier Display box incl. analysing software Sensors with Piezo technology Quartz crystals and polarised ceramic materials are used where fast response time and a high signal to noise ratio are important. Force sensors for dynamic measurement High resolution strain measurement on rigid structures Pooling and crash detection Cavity pressure measurement Direct and indirect measurement Industrial multi range charge amplifier 1.2
5 Load cell application examples Sheet thickness control Through sensors in the machine, the actual sheet thickness can be detected and the plunging depth of the upper tool automatically corrected. In this way, the machine achieves an angle quality independent of sheet thickness and with no loss of productivity or need for calibration. 1 Holding force control Holding the sheet with needed force to make sure the sheet can moved as fast as possible without any slip or marks apply on the sheet. Force control at joining process In order to maintain best possible quality of the joining process, it s elementary to control the control the force during the joining process
6 Product Summary Force Sensors Strain Sensors DLRx DSRC DSRH DSRT Load Cell Strain Ring Strain Probe Strain Links Static and dynamic force measurement Strain measurement on tie bars and shafts Strain measurement in holes Strain measurement on rigid structures Measuring range 0,5 100 kn Measuring range ±1000 µε Measuring range ±1000 µε Measuring range ±750 µε Characteristic curve deviation < 0,3% FS Characteristic curve deviation < 1% FS Characteristic curve deviation < 1%FS Characteristic curve deviation < 0,8% FS Page 2.3 Page 3.3 Page 4.3 Page 5.3 Piezo Electric Sensors DLPP DPPC Piezo electric force sensor Measurement of dynamic forces Measuring range from 2,5 to 30 kn Linearity < 1% FS Cavity pressure sensor Direct and indirect cavity pressure measurement Measuring range 2000 bar Linearity < 1% FS Page 8.3 Page
7 Analysis Devices DABx DDBF 1 Bridge amplifier Analysis of S/G bridges Display box Signal analysis of strain rings, strain probes and extensometers 2 x 1/4 bridge or full bridge Display range ±1999 µε Current or voltage output 2 or 4 channels 1 channel Page 6.3 Page 7.3 Accessories Analysis Devices DZPC DZCC DACx Accessories Coaxial Cable Industrial multi range charge amplifier Variety of mounting accessories for piezo electric sensors and cables Sensor and connecting cables for piezo electric sensors Temperature range up to +220 C Analysis of piezo electric sensors Measuring range from 100 pc to 1'000'000 pc Characteristic curve deviation < 1% FS 1 channel Page 9.19 Page 9.20 Page
8 1.6
9 Load Cells 2
10 Product Key Load cells DLRx The correct order code must be taken from the corresponding data sheet. Output P = passive U = Voltage I = Current Housing Type L001 = miniature L002 = compact L003 = large Connection S80 = 4-pin connector series 712 W24 = 4-pin open cabel end 14C = 5-pin connector M12 x 1 Precision Category B = 0,3 % Characteristic curve deviation (Type L002, Type L003) C = 0,5 % Characteristic curve deviation (Type L001) Measuring Range 150 = N 210 = kn 220 = kn 250 = kn 310 = kn 320 = kn 330 = kn 350 = kn 410 = kn Load Transmission CO = Compression TC = Tension/Compression Option C = top cover (Type L003) CL05 = 5 m cable length CL10 = 10 m cable length CCL10 = combinations possible (Type L003) DLRx L00x.xxx.xxxxxx/xxxxx 2.2
11 Summary Load cells DLRx Type DLRP L001 Compression Characteristic curve deviation: 0,5% Nominal force: kn Page 2.4 Output signal: 1 mv/v protection class: IP 67 Load transmission: compression Type DLRP L002 Compression Characteristic curve deviation: 0,3% Nominal force: 0, kn Page Output signal: 2 mv/v protection class: IP 67 Load transmission: compression Type DLRP L002 Tension/Compression Characteristic curve deviation: 0,3% Nominal force: 0, kn Page 2.8 Output signal: 2 mv/v protection class: IP 67 Load transmission: tension/compression Type DLRP L003 Tension/Compression Characteristic curve deviation: 0,3% Nominal force: kn Page 2.10 Output signal: 2 mv/v protection class: IP 67 Load transmission: tension/compression Type DLRx L001 Compression Characteristic curve deviation: 0,5% Nominal force: kn Page 2.12 Output signal: ±10 V / ma protection class: IP 65 Load transmission: compression Type DLRx L002 Compression Characteristic curve deviation: 0,3% Nominal force: 0, kn Page 2.14 Output signal: ±10 V / ma protection class: IP 65 Load transmission: compression Type DLRx L002 Tension/Compression Characteristic curve deviation: 0,3% Nominal force: 0, kn Page 2.16 Output signal: ±10 V / ma protection class: IP 65 Load transmission: tension/compression Type DLRx L003 Tension/Compression Characteristic curve deviation: 0,3% Nominal force: kn Page 2.18 Output signal: ±10 V / ma protection class: IP 65 Load transmission: tension/compression Load cells can be used in static and high dynamic applications and can be loaded by compression or tension/compression. Load cells stand for high-precision and low noise signal processing
12 Load cell DLRP L001 Features Passive load cell kn Compact dimensions For compression Protection class IP 67 Stainless steel Technical Data Standard capacities N N Sensitivity at FS 1 mv/v Combined error < 0,5% FS Linearity < 0,5% FS Hysteresis < 0,5% FS Compensated C temperature range Operating temperature C range Storage temperature range C Temperature effect zero < ±0,06% /K Temperature effect span < ±0,05% /K Zero balance < ±1% FS Non-repeatability < 0,1% FS Creep error < 0,2% FS (after 30 min. with FS) Sensitivity tolerance < ±1% FS Bridge resistance Full bridge 350 Ω Isolation resistance > 3 GΩ Excitation max. 7 V Signal polarity unipolar (compression +1mV/V) static load 150% FS dynamic load 100% FS Breaking load 220% FS Deflection FS 0,05 mm typical Protection class IP 67 Cable 2 m, shielded, PUR Load cell material Order Code DLRP L001..C CO/ Load transmission CO Compression (see drawing) Measuring range N N Combined error C 0,5% Optional cable length (2 m standard) CL05 5 m cable length CL10 10 m cable length Connection S80 4-pin connector series 712 W24 Cable, 4-wire, open cable end FS = Full scale output Combined error contains linearity, hysteresis and non-repeatability 2.4
13 DLRP L001 Dimensions (mm) + ø SR40 Connector S35A, 4-pin 2 5,5 ø 32 h8 40 Electrical Connection S80 W24 Bridge Circuit brown black blue white EXC.+ Pin 1 +VS 2 -VOUT 3 +VOUT 4 GND Housing Color brown black blue white Housing Signal +VS -VOUT GND +VOUT SIG.+ EXC.- SIG.- Wiring DLRP Transducer Precision amplifier/ power supply unit +V S Stabilized operating voltage +V Out + Gain -V Out GND - Zero 2.5
14 Load cell DLRP L002 Features Passive load cell kn Compact dimensions For compression Protection class IP 67 Stainless steel Technical Data Standard capacities N N N N N Sensitivity at FS 2 mv/v Combined error < 0,3% FS Linearity < 0,3% FS Hysteresis < 0,3% FS Compensated C temperature range Operating temperature C range Storage temperature range C Temperature effect zero < ±0,02% /K Temperature effect span < ±0,03% /K Zero balance < ±1% FS Non-repeatability < 0,1% FS Creep error < 0,15% FS (after 30 min. with FS) Sensitivity tolerance < ±1% FS Bridge resistance Full bridge 350 Ω Isolation resistance > 3 GΩ Excitation max. 7 V Signal polarity unipolar (compression +2 mv/v) static load 200% FS dynamic load 100% FS Breaking load 320% FS Deflection FS 0,05 mm typical Protection class IP 67 Cable 5 m, shielded, PUR Load cell material Order Code DLRP L002..B CO/CL10 cable length CL10 10 m (5 m standard) Load transmission CO Compression (see drawing) Measuring range N N N N N Combined error B 0,3% Connection S80 4-pin connector series 712 W24 Cable, 4-wire, open cable end FS = Full scale output Combined error contains linearity, hysteresis and non-repeatability 2.6
15 DLRP L002 Dimensions (mm) + ø 11 SR60 Connector S35A, 4-pin ,5 45 M5 x 6 / 8 (4x) ø 40 ø 47 4 fixing screws M5, strength class 10.9 Installation torque 9 Nm ø 55 Electrical Connection S80 W24 Bridge Circuit brown black blue white EXC.+ Pin Color Signal SIG.+ SIG.- 1 +VS brown +VS 2 -VOUT black -VOUT 3 +VOUT blue GND 4 GND Housing white Housing +VOUT EXC.- Wiring DLRP Transducer Precision amplifier/ power supply unit +V S Stabilized operating voltage +V Out + Gain -V Out GND - Zero 2.7
16 Load cell DLRP L002 Features Passive load cell kn Compact dimensions For tension and compression Protection class IP 67 Stainless steel Technical Data Standard capacities N N N N N Sensitivity at FS 2 mv/v Combined error < 0,3% FS Linearity < 0,3% FS Hysteresis < 0,3% FS Compensated C temperature range Operating temperature C range Storage temperature range C Temperature effect zero < ±0,02% /K Temperature effect span < ±0,03% /K Zero balance < ±1% FS Non-repeatability < 0,1% FS Creep error < 0,15% FS (after 30 min. with FS) Sensitivity tolerance < ±1% FS Bridge resistance Full bridge 350 Ω Isolation resistance > 3 GΩ Excitation max. 7 V Signal polarity bipolar (tension +2 mv/v) static load 200% FS dynamic load 100% FS Breaking load 320% FS Deflection FS 0,05 mm typical Protection class IP 67 Cable 5 m, shielded, PUR Load cell material Order Code DLRP L002..B TC/CL10 cable length CL10 10 m (5 m standard) Load transmission TC Tension/Compression (see drawing) Measuring range N N N N N Combined error B 0,3% Connection S80 4-pin connector series 712 W24 Cable, 4-wire, open cable end FS = Full scale output Combined error contains linearity, hysteresis and non-repeatability 2.8
17 DLRP L002 Dimensions (mm) SR M10 50,7 27 Connector S35A, 4-pin ,5 45 ø 40 ø 47 ø 55 M5 x 6 / 8 (4x) 4 fixing screws M5, strength class 10.9 Installation torque 9 Nm Electrical Connection S80 W24 Bridge Circuit brown black blue white EXC.+ Pin 1 +VS 2 -VOUT 3 +VOUT 4 GND Housing Color brown black blue white Housing Signal +VS -VOUT GND +VOUT SIG.+ EXC.- SIG.- Wiring DLRP Transducer Precision amplifier/ power supply unit +V S Stabilized operating voltage +V Out + Gain -V Out GND - Zero 2.9
18 Load cell DLRP L003 Features Passive load cell kn Compact dimensions For tension and compression Protection class IP 67 Corrosion-resistant steel Technical Data Standard capacities N N N N N Sensitivity at FS 2 mv/v Combined error < 0,3% FS Linearity < 0,3% FS Hysteresis < 0,3% FS Compensated C temperature range Operating temperature C range Storage temperature range C Temperature effect zero 0,02% /K Temperature effect span < 0,02% /K Zero balance < ±1% FS Non-repeatability < 0,1% FS Creep error < 0,2% FS (after 30 min. with FS) Sensitivity tolerance < ±1% FS Bridge resistance Full bridge 350 Ω Isolation resistance > 3 GΩ Excitation max. 7 V Signal polarity bipolar (tension +2 mv/v) static load 150% FS dynamic load 100% FS Breaking load 220% FS Deflection FS 0,05 mm typical Protection class IP 67 Cable 5 m, shielded, PUR Load cell material , nickel-plated Order Code DLRP L003..B TC/ Load transmission TC Tension/Compression (see drawing) Measuring range N N N N N Combined error B 0,3% Connection S80 4-pin connector series 712 W24 Cable, 4-wire, open cable end Option C Top cover CL10 10 m cable length (5 m standard) CCL10 Combinations possible FS = Full scale output Combined error contains linearity, hysteresis and non-repeatability
19 + - DLRP L003 Dimensions (mm) ø 54 M30 x 2 2 ø 155 ø 130 ø 106 ø 11 x ,5 Bushing, 4-pin 12 fixing screws M10, strength class 10.9 Installation torque 42Nm ø 155 Electrical Connection S80 W24 Bridge Circuit brown black blue white EXC.+ Pin 1 +VS 2 -VOUT 3 +VOUT 4 GND Housing Color brown black blue white Housing Signal +VS -VOUT GND +VOUT SIG.+ EXC.- SIG.- Wiring DLRP Transducer Precision amplifier/ power supply unit +V S Stabilized operating voltage +V Out + Gain -V Out GND - Zero
20 Load cell with amplifier DLRx L001 Features Voltage (DLRU) or current output (DLRI) Compact dimensions For compression Protection class IP 65 Stainless steel Technical Data Technical Data Standard capacities N Cable 2 m, shielded, PUR, N (between amplifier and sensor) Output signal at FS DLRU V Load cell material DLRI ma Order Code Linearity 0,5% FS Hysteresis 0,5% FS DLRP L001..C CO/ Non-repeatability < 0,1% FS Optional cable length (2 m standard) Creep error < 0,2% FS (after 30 min. with FS) CL05 5 m cable length Zero balance DLRU < 5 mv CL10 10 m cable length DLRI < 8 µa Load transmission Reset-Input active VDC < 2 ma Reset-Input inactive < 1 VDC CO Compression (see drawing) Reset-Pulse > 1 ms Measuring range Reset time < 5 ms N Switching frequency 1000 Hz N Signal polarity DLRU unipolar (compression +10 V) Combined error DLRI unipolar (compression 20 ma) C 0,5% Noise DLRU (0...5 khz) < 5 mvpp Connection DLRI (0...5 khz) < 8 µapp 14C 5-pin connector series M12 x 1 Compensated C Output temperature range U Voltage output V Operating temperature C I Current output ma range Storage temperature range C Accessories (not included in delivery) Temperature effect zero < ±0,05% /K Temperature effect span < ±0,06% /K Cable between the amplifier and the control unit. Bridge resistance Full bridge 350 Ω Series 713 Isolation resistance > 3 GΩ Connector female, control side, 5-pin, Part No Excitation DLRU V DLRI V M12 x 1 Supply current DLRU < 60 ma DLRI < 90 ma Connector female with cable, control side, 5-pin static load 150% FS ESG 34CH0200G 5-pin (shielded) 2 m, PUR, dynamic load 100% FS (Part No ) Breaking load 220% FS ESG 34CH0500G 5-pin (shielded) 5 m, PUR, Protection class IP 65 (Part No ) FS = Full scale output ESG 34CH1000G 5-pin (shielded) 10 m, PUR, (Part No )
21 DLRx L001 Dimensions (mm) Load cell Amplifier DABx AD2T + 2 5, ø 8 40 SR40 Connector S35A, 4-pin M12 x ø 32 h8 40 Electrical Connection DLRU 14C DLRI 14C Bridge Circuit EXC SIG.+ SIG.- Pin 1 +VS 2 -VOUT 3 GND 4 +VOUT 5 Reset Housing Pin 1 +VS 2 n.c. 3 GND 4 +lout 5 Reset Housing EXC.- Wiring DLRU DLRI F 1 +VS 3 GND 18-33VDC F 1 +VS 3 GND 14-33VDC 2 -VOUT 2 n.c. U 4 +VOUT 5 Reset R L ±10 V 5 33 VDC I 4 +IOUT 5 Reset R L 4 20 ma 5 33 VDC
22 Load cell with amplifier DLRx L002 Features Voltage (DLRU) or current output (DLRI) Compact dimensions For compression Protection class IP 65 Stainless steel Technical Data Standard capacities N N N N N Output signal at FSR DLRU V DLRI ma Linearity 0,5% FS Hysteresis 0,5% FS Non-repeatability < 0,1% FS Creep error < 0,15% FS (after 30 min. with FS) Zero balance DLRU < 5 mv DLRI < 8 µa Reset-Input active VDC < 2 ma Reset-Input inactive < 1 VDC Reset-Pulse > 1 ms Reset time < 5 ms Switching frequency 1000 Hz Signal polarity DLRU unipolar (compression +10 V) DLRI unipolar (compression 20 ma) Noise DLRU (0...5 khz) < 5 mvpp DLRI (0...5 khz) < 8 µapp Compensated C temperature range Operating temperature C range Storage temperature range C Temperature effect zero < ±0,02% /K Temperature effect span < ±0,03% /K Bridge resistance Full bridge 350 Ω Isolation resistance > 3 GΩ Excitation DLRU V DLRI V Supply current DLRU < 60 ma DLRI < 90 ma static load 200% FS dynamic load 100% FS Breaking load 320% FS Protection class IP 65 FS = Full scale output 2.14 Technical Data Cable Order Code Load cell material DLRP L002..B CO/CL10 Load transmission CO Compression (see drawing) Measuring range N N N N N Combined error B 0,3% Connection 14C 5-pin connector series M12 x 1 Output U Voltage output V I Current output ma Accessories (not included in delivery) Series m, shielded, PUR, (between amplifier and sensor) Cable length CL10 10 m cable length (5 m standard) Cable between the amplifier and the control unit. Connector female, control side, 5-pin, Part No M12 x 1 Connector female with cable, control side, 5-pin ESG 34CH0200G 5-pin (shielded) 2 m, PUR, (Part No ) ESG 34CH0500G 5-pin (shielded) 5 m, PUR, (Part No ) ESG 34CH1000G 5-pin (shielded) 10 m, PUR, (Part No )
23 DLRx L002 Dimensions (mm) Load cell + Amplifier DABx AD2T ø 11 SR60 Connector S35A, 4-pin M12 x ,5 45 M5 x 6 / 8 (4x) 9 79 ø 40 ø 47 4 fixing screws M5, strength class 10.9 Installation torque 9 Nm ø 55 Electrical Connection DLRU 14C DLRI 14C Bridge Circuit EXC SIG.+ SIG.- Pin 1 +VS 2 -VOUT 3 GND 4 +VOUT 5 Reset Housing Pin 1 +VS 2 n.c. 3 GND 4 +lout 5 Reset Housing EXC.- Wiring DLRU DLRI F 1 +VS 3 GND 18-33VDC F 1 +VS 3 GND 14-33VDC 2 -VOUT 2 n.c. U 4 +VOUT 5 Reset R L ±10 V 5 33 VDC I 4 +IOUT 5 Reset R L 4 20 ma 5 33 VDC
24 Load cell with amplifier DLRx L002 Features Voltage (DLRU) or current output (DLRI) Compact dimensions For tension or compression (DLRI) For tension and compression (DLRU) Protection class IP 65 Stainless steel Technical Data Technical Data Cable 5 m, shielded, PUR, Standard capacities N N (between amplifier and sensor) N N N Load cell material Output signal at FSR DLRU ±10 V Order Code DLRI ma DLRP L002..B TC/ CL10 / Linearity 0,3% FS Polarity Hysteresis 0,3% FS SP Altered Non-repeatability < 0,1% FS polarity Creep error < 0,15% FS (after 30 min. with FS) Option Zero balance DLRU < 5 mv CL10 10 m cable length DLRI < 8 µa (5 m standard) Reset-Input active VDC < 2 ma Load transmission Reset-Input inactive < 1 VDC TC Tension/Compression (see drawing) Reset-Pulse > 1 ms Measuring range Reset time < 5 ms N N Switching frequency 1000 Hz N N Signal polarity DLRU bipolar (tension +10 V) N DLRI unipolar (tension 20 ma) Combined error Noise DLRU (0...5 khz) < 5 mvpp B 0,3% DLRI (0...5 khz) < 8 µapp Connection Compensated C 14C 5-pin connector series M12 x 1 temperature range Output Operating temperature C U Voltage output ±10 V range I Current output ma Storage temperature range C Accessories (not included in delivery) Temperature effect zero < ±0,02% /K Cable between the amplifier and the control unit. Temperature effect span < ±0,03% /K Series 713 Bridge resistance Full bridge 350 Ω Isolation resistance > 3 GΩ Connector female, control side, 5-pin, Part No Excitation DLRU V DLRI V M12 x 1 Supply current DLRU < 60 ma Connector female with cable, control side, 5-pin DLRI < 90 ma ESG 34CH0200G 5-pin (shielded) 2 m, PUR, static load 200% FS (Part No ) dynamic load 100% FS ESG 34CH0500G 5-pin (shielded) 5 m, PUR, Breaking load 320% FS (Part No ) Protection class IP 65 ESG 34CH1000G 5-pin (shielded) 10 m, PUR, FS = Full scale output (Part No )
25 DLRx L002 Dimensions (mm) Load cell + - SR40 Amplifier DABx AD2T ,7 M10 Connector S35A, 4-pin M12 x , M5 x 6 / 8 (4x) ø 40 ø 47 4 fixing screws M5, strength class 10.9 Installation torque 9 Nm ø 55 Electrical Connection DLRU 14C DLRI 14C Bridge Circuit EXC SIG.+ SIG.- Pin 1 +VS 2 -VOUT 3 GND 4 +VOUT 5 Reset Housing Pin 1 +VS 2 n.c. 3 GND 4 +lout 5 Reset Housing EXC.- Wiring DLRU DLRI F 1 +VS 3 GND 18-33VDC F 1 +VS 3 GND 14-33VDC 2 -VOUT 2 n.c. U 4 +VOUT 5 Reset R L ±10 V 5 33 VDC I 4 +IOUT 5 Reset R L 4 20 ma 5 33 VDC
26 Load cell with amplifier DLRx L003 Features Voltage (DLRU) or current output (DLRI) Compact dimensions For tension (DLRI) and tension/compression (DLRU) Protection class IP 65 Corrosion-resistant steel Technical Data Standard capacities N N N N N Output signal at FSR DLRU ±10 V DLRI ma Linearity 0,3% FS Hysteresis 0,3% FS Non-repeatability < 0,1% FS Creep error < 0,2% FS (after 30 min. with FS) Zero balance DLRU < 5 mv DLRI < 8 µa Reset-Input active VDC < 2 ma Reset-Input inactive < 1 VDC Reset-Pulse > 1 ms Reset time < 5 ms Switching frequency 1000 Hz Signal polarity DLRU bipolar (tension +10 V) DLRI unipolar (tension 20 ma) Noise DLRU (0...5 khz) < 5 mvpp DLRI (0...5 khz) < 8 µapp Compensated C temperature range Operating temperature C range Storage temperature range C Temperature effect zero < ±0,02% /K Temperature effect span < ±0,03% /K Bridge resistance Full bridge 350 Ω Isolation resistance > 3 GΩ Excitation DLRU V DLRI V Supply current DLRU < 60 ma DLRI < 90 ma Permitted static load 200% FS dynamic load 100% FS Breaking load 320% FS Protection class IP 65 FS = Full scale output 2.18 Technical Data Load cell material Order Code DLRP L003..B TC/ Option C Top cover SP Altered polarity CSP Combinations possible Load transmission TC Tension/Compression (see drawing) Measuring range N N N N N Combined error B 0,3% Connection 14C 5-pin connector series M12 x 1 Output U Voltage output ±10 V I Current output ma Accessories (not included in delivery) Series 713 Connector female, control side, 5-pin, Part No M12 x , nickel-plated Cable between the amplifier and the control unit. Connector female with cable, control side, 5-pin ESG 34CH0200G 5-pin (shielded) 2 m, PUR, (Part No ) ESG 34CH0500G 5-pin (shielded) 5 m, PUR, (Part No ) ESG 34CH1000G 5-pin (shielded) 10 m, PUR, (Part No )
27 DLRx L003 Dimensions (mm) + - ø 53,5 M30 x , ø 155 ø 130 ø 106 ø 11 x fixing screws M10, strength class 10.9 Installation torque 42 Nm Electrical Connection DLRU 14C DLRI 14C Bridge Circuit EXC SIG.+ SIG.- Pin 1 +VS 2 -VOUT 3 GND 4 +VOUT 5 Reset Housing Pin 1 +VS 2 n.c. 3 GND 4 +lout 5 Reset Housing EXC.- Wiring DLRU DLRI F 1 +VS 3 GND 18-33VDC F 1 +VS 3 GND 14-33VDC 2 -VOUT 2 n.c. U 4 +VOUT 5 Reset R L ±10 V 5 33 VDC I 4 +IOUT 5 Reset R L 4 20 ma 5 33 VDC
28 2.20
29 Strain Rings 3
30 Product Key Strain Rings DSRC The correct order code must be taken from the corresponding data sheet. DSRC BT053M/CM Product Description DS = Strain sensor Method R = Resistive Series C = Series C (strain ring) Type ST = Standard, 6 pin connector radial, 2 x 1/4 S/G bridge, k = 2,00 BT = Execution with radial cable exit, w/o connector, cable 5 m, 2 x 1/4 S/G bridge, k = 2,00 QM = Quick mount, with hinge and quick mount latch, 6 pin connector radial, with bayonet lock, 2 x 1/4 S/G bridge, k = 2,00 AX = Execution with axial cable exit, w/o connector, cable 5 m, 2 x 1/4 S/G bridge, k = 2,00 Nominal Size (mm) Shaft Diameter Metric sizes = Ring diameter in mm Inch sizes = Inch size converted to mm and rounded to next closest integer mm Example 053 = 53 mm Metric / Inch M = Metric Options /TO = Execution for torsion measurement 2 x 1/4 S/G bridge 350 Ω, k = 2,00 /CM = 4 pin cable connector /CN = 6 pin cable connector /CL10 = Cable length 10 m Combinations are possible: example CL10CM or CL10TO Note the Following Important Points When applying the strain ring: The strain rings are not suitable for static applications. Reset measuring chain before each cycle. The strain rings are equipped with two exactly diametrically opposed strain gages. Possible bridge circuits: Bending compensated with 2 x 1/4 bridge configuration of both strain gages. Axial load compensated with 1/2 bridge configuration of both strain gages. For strain rings with full bridge circuit, the corresponding cable must be used. The bridge is completed with precision resistors. After several hundred repeated installations, the stainless metal foil in the ring may be damaged. Under normal circumstances, this does not compromise the measurement accuracy as long as the gages remain properly aligned. The strain rings can be returned to Baumer for reconditioning. All components involved in the measurement are exchanged (Part No ). The strain ring will be shipped back in a 'as new' condition including a certificate of conformity
31 Summary Strain Rings DSRC Type ST Standard strain ring with radial connector for tension, compression or torsion measurements Page 3.4 Installation without surface preparation Simple strain measurement on shafts, axes and cylinders Only for cyclical applications, i.e. clamping force measurements on presses Type BT Strain ring with radial cable exit for tension and compression measurements Page Installation without surface preparation OEM execution Ideal for permanent installation Only for cyclical applications, i.e. clamping force measurements on presses Type QM Strain ring with quick mount latch for tension and compression measurements Page 3.12 Installation without surface preparation Fast and simple installation thanks to a quick mount latch Ideal for restricted space conditions Only for cyclical applications, i.e. clamping force measurements on presses Type AX Strain ring with axial cable exit Page 3.16 Installation without surface preparation Ideal for use in conjunction with telemetry system For tension, compression or torsion measurements Only for cyclical applications, i.e. clamping force measurements on presses The strain rings are based on the proven STRAIN-MATE TM technology with strain gages. Strain rings are used in general mechanical engineering applications as well as in the laboratory. Simple installation combined with high accuracy make the strain ring a versatile measurement tool for calibration and monitoring tasks
32 Strain Ring with Radial Connector DSRC ST Features Standard strain ring Simple strain measurements on shafts, axles and cylinders Installation without surface preparation For tension, compression or torque measurements For cyclical applications only, i.e. clamping force on presses Strain Gage Data Strain gage type Foil gages Bridge resistance 350 Ω 2 x quarter bridge at 24 C Sensitivity Gage factor K= 2.00 ±0,5% at 24 C (compensated with resistors) Temp. compensation Steel Transverse sensitivity +0,7% nominal Bridge circuit 2 x 1/4 bridge (see electrical connections) Mechanical Data Connection 6 pin female (Binder series 423) Material - Ring Aluminum anodized - Protective foil Stainless steel - Hinge Nitril - Screws M8 (torque 3 Nm) Environmental Conditions Surface quality Ra 3.2 (N8) or better Operating temp. range C Storage temperature C Protection class IP 54 Electrical Data Measuring range ±1000 µε (1 µε = 0,001 mm/m resp. 1 µε equals 0,001 mm strain per meter of shaft) Output signal 1 mv/v per 1000 µε (with completed full bridge) Combined error < 1% FS Linearity < 0,5% FS Hysteresis < 0,5% FS Repeatability < 0,2% FS Zero, bridge balance < ±200% FS (depending on installation). Since the gages are pressed-on, the bridge can have any arbitrary zero offset after the ring is mounted. Baumer amplifiers and display boxes are equipped with a reset function to tare this offset. The bridge should be reset before each measuring cycle. Excitation max. 9 VDC Recommended 5 VDC Signal polarity The signal polarity depends on the bridge circuit. In combination with Baumer amplifiers, the polarity is positive under tensile load. Rise time (10-90%) < 1 ms (on steel) 3.4
33 DSRC ST Dimensions (mm) M8 Ød 41,1 12,5 ØD + 34 ØD ,1 3 Ø d = Ø D +0,1-0, ,1 Ø ,8 54 Ø D = Nominal diameter Ø d = Shaft diameter ε = Strain = Gage location Electrical Connections Bridge Circuit R C SIG.+ S/G DMS 11 Wiring Diagram EXC.+ DMS S/G 2 SIG.- R C EXC.- Pin Assignment (per ring half) Pin Signal 1 S/G 2 S/G 3 n.c. 4 n.c. 5 n.c. 6 n.c. DSRC Amplifier Potential equalisation, low impedance 3.5
34 Strain Ring with Radial Connector DSRC ST Typical Measuring Chains 4 Order Code DSRC ST M / Option /TO Execution for torsion measurement 2 x 1/4 S/G bridge 350 Ω, k = 2,00 Unit 2 M Metric sizes Nominal diameter* 1 Metric (M) 3 Pos. Qty Type Description 1 1 DSRC Type ST Standard strain ring 2 1 DZCY 05-ST-WM-C Connecting cable for strain ring, 5 m 3 1 DDBF 2-SC 2-channel display box incl. power adapter * Other diameters available upon request DZMT TW-A1-6 Torque wrench 4 2 Accessories 1 3 Torque wrench, range adjustable 1-6 Nm Torque wrench fix factory setting 3 Nm Order code: DZMT TW-A1-6 Order code: DZMT TW-F3 Pos. Qty Type Description 1 4 DSRC Typ ST Standard strain ring 2 4 DZCY 05-ST-WM-C Connecting cable for strain ring, 5 m 3 1 DDBF 4-SC 4-channel display box incl. power cord and Analysis Software 4 1 DZMT TW-A1-6 Torque wrench 3.6
35 DSRC ST Accessories Connecting Cable for display box and Bridge Amplifier Connecting Cable with Open Leads Binder Series 423 Binder Series L Binder Series 712 DZCY -ST-WM-C DZCY -ST-WO-C Length L 05 5 m m Length L 05 5 m m Binder Series 712 Wire Colors grey white blue green brown yellow Pin Signal 1 S/G 1 2 S/G 1 3 S/G 2 4 S/G 2 Color Signal grey S/G 1 white S/G 1 blue n.c. green S/G 2 brown S/G 2 yellow n.c. Order Code DZCY -ST -C Length L 05 5 m m m Connection types WO right angle connector 6-pin open end WM right angle connector 6-pin / 4-pin straight connector (amplifier DDBF/DABU AD2T) 3.7
36 Strain Ring with Radial Cable DSRC BT Features OEM execution Installation without surface preparation Ideal for permanent installation For tension and compression measurements For cyclical applications only, i.e. clamping force on presses Strain Gage Data Strain gage type Bridge resistance at 24 C Mechanical Data Connection Open leads Material - Ring Aluminum anodized - Protective foil Stainless steel - Screws M8 (torque 3 Nm) Cable 5 m 2 core, shielded, PVC Environmental Conditions Foil gages 350 Ω 2 x quarter bridge (without cable) Sensitivity Gage factor K= 2.00 ±0,5% at 24 C (compensated with resistors) Temp. compensation Steel Transverse sensitivity +0,7% nominal Bridge circuit 2 x 1/4 bridge (see electrical connections) Surface installation spot Ra 3.2 (N8) or better Operating temp. range C Storage temperature C Protection class IP 54 Electrical Data Measuring range ±1000 µε (1 µε = 0,001 mm/m resp. 1 µε equals 0,001 mm strain per meter of shaft) Output signal 1 mv/v per 1000 µε (with completed full bridge) Combined error < 1% FS Linearity < 0,5% FS Hysteresis < 0,5% FS Repeatability < 0,2% FS Zero, bridge balance < ±200% FS (depending on installation) Since the gages are pressed-on, the bridge can have any arbitrary zero offset after the ring is mounted. Baumer amplifiers and display boxes are equipped with a reset function to tare this offset. The bridge should be reset before each measuring cycle. Excitation max. 9 VDC Recommended 5 VDC Signal polarity The signal polarity depends on the bridge circuit. In combination with Baumer amplifiers, the polarity is positive under tensile load. Rise time (10-90%) < 1 ms (on steel) 3.8
37 DSRC BT Dimensions (mm) 5m M8 ca. ØD +34 Ød... 3 ØD 3 Ø d = Ø D +0,1-0, Ø D = Nominal diameter Ø d = Shaft diameter ε = Strain = Gage location Electrical Connections Bridge Circuit SIG.+ R C EXC.+ DMS S/G 2 SIG.- Wire Color (per ring half) brown white Color brown white Signal S/G S/G S/G DMS 11 R C Option /CN Wiring Diagram EXC.- DSRC Amplifier Series 423 Potential equalisation, low impedance Pin Signal 1 S/G 1 2 S/G 1 3 n.c. 4 S/G 2 5 S/G 2 6 n.c
38 Strain Ring with Radial Cable DSRC BT Typical Measuring Chain Order Code DSRC BT M / 3 1 Option /CM Connector 4 pin male installed (Connecting display box) /CN Connector 6 pin male installed (Connecting Amplifier) /CL10 Cable length 10 m /CL10CM Cable length 10 m with connector 4 pin /CL10CN Cable length 10 m with connector 6 pin Unit M Metric sizes 2 Pos. Qty Type Description 1 1 DSRC Type BT Strain ring with radial cable 2 1 DABU MP4M Bridge amplifier 3 1 DZMT TW-A1-6 Torque wrench Nominal diameter* Metric (M) * Other diameters available upon request Accessories Torque wrench, variable adjustable range 1-6 Nm Torque wrench fix factory setting 3 Nm Order code: DZMT TW-A1-6 Order code: DZMT TW-F
39 DSRC BT
40 Strain Ring with Quick Mount Latch DSRC QM Features Installation without surface preparation Simple and fast installations thanks to a quick mount latch For tension and compression measurement Ideal for restricted space conditions For cyclical applications only Strain Gage Data Strain gage type Foil gages Bridge resistance 350 Ω 2 x quarter bridge at 24 C Sensitivity Gage factor K= 2.00 ±0,5% at 24 C (compensated with resistors) Temp. compensation Steel Transverse sensitivity +0,7% nominal Bridge circuit 2 x 1/4 bridge (see electrical connections) Mechanical Data Connection 6 pin female (bayonet quick con.) Material - Ring Aluminum anodized - Protective foil Stainless steel - Hinge Steel - Mounting buckle Steel Environmental Conditions Surface installation spot Ra 3.2 (N8) or better Operating temp. range C Storage temperature C Protection class IP 54 Electrical Data Measuring range ±1000 µε (1 µε = 0,001 mm/m resp. 1 µε equals 0,001 mm strain per meter of shaft) Output signal 1 mv/v per 1000 µε (with completed full bridge) Combined error < 1% FS Linearity < 0,5% FS Hysteresis < 0,5% FS Repeatability < 0,2% FS Zero, bridge balance < ±200% FS (depending on installation) Since the gages are pressed-on, the bridge can have any arbitrary zero offset after the ring is mounted. Baumer amplifiers and display boxes are equipped with a reset function to tare this offset. The bridge should be reset before each measuring cycle. Excitation max. 9 VDC Recommended 5 VDC Signal polarity The signal polarity depends on the bridge circuit. In combination with Baumer amplifiers, the polarity is positive under tensile load. Rise time (10-90%) < 1 ms (on steel)
41 DSRC QM Dimensions (mm) 40,5 ØD +34 ØD Ød Ø d = Ø D +0,1-0, ,5 4 D+24 Ø D = Nominal diameter Ø d = Shaft diameter ε = Strain = Gage location Electrical Connections Bridge Circuit R C SIG.+ S/G DMS 11 EXC.+ DMS S/G 2 SIG.- R C EXC.- Pin Assignment (per ring half) Pin Signal 1 S/G 2 S/G 3 n.c. 4 n.c. 5 n.c. 6 n.c. Wiring Diagram DSRC Amplifier Potential equalisation, low impedance
42 Strain Ring with Quick Mount Latch DSRC QM Typical Measuring Chains Order Code DSRC QM M 2 Unit M Metric sizes 1 3 Pos. Qty Type Description 1 1 DSRC Typ QM Strain ring with quick mount latch 2 1 DZCY 05-ST-BM-C Connecting cable for strain ring, 5 m 3 1 DDBC 2-SC 2-Channel display box incl. power adapter and Analysis Software Nominal diameter* Metric (M) * Other diameters available upon request Pos. Qty. Type Description 1 4 DSRC Typ QM Strain ring with quick mount latch 2 4 DZCY 05-ST-BM-C connecting cable for strain ring, 5 m 3 1 DDBF 4-SC 4-Channel display box incl. power cord and Analysis Software
43 DSRC QM Accessories Connecting Cable for Display and Bridge Amplifier Connecting Cable with Open Leads Binder Series 678 Binder Series L 50 L Binder Series 712 DZCY -ST-BM-C DZCY -ST-BO-C Length L 05 5 m m Length L 05 5 m m Binder Series Wire Color grey white blue green brown yellow Pin Signal 1 S/G 1 2 S/G 1 3 S/G 2 4 S/G 2 color Signal grey S/G 1 white S/G 1 blue n.c. green S/G 2 brown S/G 2 yellow n.c. Order Code DZCY -ST -C Length L 05 5 m m m Connection types BO right angle connector 6-pin open end BM right angle connector 6-pin / 4-pin straight connector (amplifier DDBF/DABU AD2T)
44 Strain Ring with Axial Cable Exit DSRC AX Features Ideal for use with telemetry system For tension and compression measurement Installation without surface preparation For cyclical applications only Strain Gage Data Strain gage type Bridge resistance at 24 C Mechanical Data Connection Open leads Material - Ring Aluminum anodized - Protective foil Stainless steel - Screws M8 (torque 3 Nm) - Hinge Nitril Cable 5 m 2 core, shielded, PVC Environmental Conditions Foil gages 350 Ω 2 x quarter bridge (without cable) Sensitivity Gage factor K= 2.00 ±0,5% at 24 C (compensated with resistors) Temp. compensation Steel Transverse sensitivity +0,7% nominal Bridge circuit 2 x 1/4 bridge (see electrical connections) Surface installation spot Ra 3.2 (N8) or better Operating temp. range C Storage temperature C Protection class IP 54 Electrical Data Measuring range ±1000 µε (1 µε = 0,001 mm/m resp. 1 µε equals 0,001 mm strain per meter of shaft) Output signal 1 mv/v per 1000 µε (with completed full bridge) Combined error < 1% FS Linearity < 0,5% FS Hysteresis < 0,5% FS Repeatability < 0,2% FS Zero, bridge balance < ±200% FS (depending on installation) Since the gages are pressed-on, the bridge can have any arbitrary zero offset after the ring is mounted. Baumer amplifiers and display boxes are equipped with a reset function to tare this offset. The bridge should be reset before each measuring cycle. Excitation max. 9 VDC Recommended 5 VDC Signal polarity The signal polarity depends on the bridge circuit. In combination with Baumer amplifiers, the polarity is positive under tensile load. Rise time (10-90%) < 1 ms (on steel)
45 DSRC AX Dimensions (mm) M8 12 5m ØD+34 ØD Ød Ø d = Ø D +0,1-0, Ø D = Nominal diameter Ø d = Shaft diameter ε = Strain = Gage location Electrical Connections Bridge Circuit SIG.+ R C EXC.+ DMS S/G 2 SIG.- Wire Color (per ring half) brown white Color brown white Signal S/G S/G S/G DMS 1 R C Option /CN Wiring Diagram EXC.- DSRC Amplifier Series 423 Potential equalisation, low impedance Pin Signal 1 S/G 1 2 S/G 1 3 n.c. 4 S/G 2 5 S/G 2 6 n.c
46 Strain Ring with Axial Cable Exit DSRC AX Typical Measuring Chain Pos. Qty Type Description 1 1 DSRC Type AX Strain ring with axial cable exit 2 1 DZMT TW-A1-6 Torque wrench 3 1 Commercially available telemetry system Order Code DSRC AX M / Unit /TO /CM /CN /CL10 M Metric sizes Option Nominal diameter* Metric (M) Execution for torsion measurement 2 x 1/4 bridge 350 Ω, k = 2,00 Connector 4-pin male installed (Connecting Display box) Connector 6-pin male installed (Connecting Amplifier) Cable length 10 m /CL10CM Cable length 10 m with connector 4-pin /CL10CN Cable length 10 m with connector 6-pin * Other diameters available upon request Accessories Torque wrench, variable adjustable range 1-6 Nm Torque wrench, fix factory setting 3 Nm Order code: DZMT TW-A1-6 Order code: DZMT TW-F
47 Strain Probes 4
48 Product Key Strain Probes DSRH The correct order code must be taken from the corresponding data sheet. DSRH U M/CM Product Description DS = Strain sensor Method R = Resistive Series H = Series H (Strain probes) Type I = With integrated amplifier, output signal 4-20 ma U = With integrated amplifier, output signal 0-10 V Nominal Size (mm) (tip diameter) 16 = 16 mm 20 = 20 mm Measurement Depth (mm) Example 0400 = 400 mm 1930 = 1930 mm Metric M = Metric Option /CM = 4 pin connector male installed (only for type P) /CN = 6 pin cable connector installed (only for type P) /CL10 = cable length 10 m (only for type P) Combinations are possible: example CL10CN Note the following important points When applying the strain probe: The strain probes are not suitable for static applications. Reset measuring chain before each cycle. The sensor tip is equipped with two exactly diametrically opposed strain gages. Excessive removal and installation can damage the tip. Under normal circumstances this does not compromise the measurement accuracy as long as the gages remain properly aligned. When the probe is installed and removed on a regular basis, the resilient steel tip option is recommended. The surface of the bore does not have to be very smooth but it should be free of grooves and must be clean
49 Summary Strain Probes DSRH Type 16/20 Strain probe with integrated amplifier Simple strain measurements in deep holes Characteristic curve deviation < 1% For cyclical applications only Integrated amplifier with voltage or current output Page 4.4 With the strain probes it is possible for the first time to measure strain in deep, previously inaccessible holes. A strain probe which is equipped with two diametrically opposed strain gages at the tip is inserted into a hole and clamped. By bracing the gages against the wall of the bore hole the strain is transmitted by friction contact. The bracing element serves as mounting element as well. Since the clamping mechanism is acting only locally in the area of the gages, the probes measure the strain with high accuracy. The strain probes are based on the proven STRAIN-MATE TM technology with strain gages. 4 Strain probes are used in general mechanical engineering applications as well as in the laboratory. Simple installation combined with high accuracy makes the strain probe a versatile measurement tool for calibration and monitoring tasks
50 Strain Probe with Integrated Amplifier DSRH x16/x20 Features Simple strain measurements in deep holes Characteristic curve deviation < 1% For cyclical applications only Integrated amplifier with voltage or current output Electrical Data DSRH U DSRH I Measuring range ±1000 µε µε Strain gage type Foil gages S/G circuit 2 x 1/4 bridge bending compensated Output signal ±10 V calibrated 4-20 ma (max. ±12 V) max. load 500 Ω Combined error < 1% FS Linearity < 0,5% FS Hysteresis < 0,5% FS Supply voltage range VDC Current draw < 30 ma < 45 ma Output impedance 50 Ω - Zero < ±10 mv < ±20 µa reset active Reset input VDC galvanically isolated Reset/operate offset < ±4 mv < ±10 µa Reset pulse (t1) > 1 ms Reset settle time (t2) 60 ms Frequency range (3 db) 120 Hz Rise time 10-90% < 3 ms Signal polarity positive positive tensile load (only tensile load possible) Mechanical Data Connection 7 pin male (Series 680/SGR 70) Material - Amplifier enclosure Aluminum anodized - Tube Stainless steel - Support ring (Type 20) Aluminum anodized Hexagon socket 6 mm Installation torque 3 Nm Environmental Conditions Surface installation spot Ra 3.2 (N8) or better Operating temp. range C non condensing Storage temperature C Protection class IP
51 DSRH x16/x20 Dimensions (mm) Type 16 Ø LM Ø64,5 ØDS 55 Ø15 45 LM + 40 ca. 50 Type 20 Ø LM Ø 64,5 ØDS 55 Ø15 45 LM + 40 ca. 50 Ø DS = Tip diameter LM = Measurement depth ε = Strain = Gage location 4.5
52 Strain Probe with Integrated Amplifier DSRH x16/x20 Electrical Connections Current Output Voltage Output Order Code DSRH - M Pin Signal 1 +Vs (18-35 VDC) 2 TestOUT 3 Reset (bipolar) 4 Reset (bipolar) 5 +IOUT (4-20 ma) 6 -IOUT 7 GND Pin Signal 1 +Vs (18-35 VDC) 2 TestOUT 3 Reset (bipolar) 4 Reset (bipolar) 5 +VOUT (±10 V) 6 -VOUT 7 GND Output signal U Voltage output ±10 V ±1000 µε = ±10 V I Current output 4-20 ma µε = 20 ma Tip diameter (Ø DS) - Length (LM) Control Reset galvanically isolated DSRH Controller Reset Function V OUT V S Test OUT Reset (bipolar) Reset (bipolar) +V OUT /+I OUT -V OUT /-I OUT GND R L VDC ±10 V Reset switch VDC ±10 V 4-20 ma U Reset t Reset not galvanically isolated DSRH V S Test OUT Reset (bipolar) Reset (bipolar) +V OUT /+I OUT -V OUT /-I OUT Controller R L VDC ± 10 V Reset switch ± 10 V 4-20 ma Measure V/I OUT Reset t 1 t 2 t 1 t 2 Output signal Reset input (active high) Reset pulse (> 1 ms) Reset settle time after reset pulse ( 60 ms) t 7 GND 4.6
53 DSRH x16/x20 Accessories and Control Elements Connecting Cable with Flying Leads Control Elements Series 423 S1 LED P1 P2 L 50 4 Length Order Code 5 m DZCS 05/ m DZCS 10/ P1 P2 LED S1 Adjustment TestOUT Adjustment Gain (factory set) Control-LED for TestOUT Mounting screw with 6 mm hex brown white grey yellow green blue pink Color white brown green yellow grey blue pink Signal +Vs (18-35 VDC) TestOUT Reset (bipolar) Reset (bipolar) +IOUT / +VOUT -IOUT / -VOUT GND Straight Connector Series 423 Torque Wrench 68 Part No Order code: DZMT TW-A1-6 adjustable from 1-6 Nm Part No Order code: DZMT TW-F3 preset fix to 3 Nm Part No
54 4.8
55 Strain Links 5
56 Product Key Strain Links DSRT The correct order code must be taken from the corresponding data sheet. DSRT 22DD-S Product Description DS = Strain sensor Method R = Resistive Series T = Strain link Type 22DA = 25,9 x 70 x16,9 mm, for static and dynamic applications, without amplifier 22DD = 25,9 x 70 x 16,9 mm, for static and dynamic applications, with voltage output 22DJ = 25,9 x 70 x 16,9 mm, for cyclical applications, CANopen, with integrated amplifier Electric Connection S5 = Cable, 5 pin connector, M12 x 1 Sensitivity 1.00 = 1,00 mv/v at 250 µε surface strain 1.25 = 1,25 mv/v at 250 µε surface strain 0100 = 100 µε surface strain with nominal output signal 0250 = 250 µε surface strain with nominal output signal 0350 = 350 µε surface strain with nominal output signal 0500 = 500 µε surface strain with nominal output signal 0750 = 750 µε surface strain with nominal output signal 5.2
57 Summary Strain Links DSRT Type 22DA Strain link without amplifier For static and dynamic applications Very good repeatability Measurement range from ±100με up to ±750με Overloadsave Page 5.4 Type 22DD Surface strain sensor with integrated amplifier For static and dynamic applications Integrated reset circuit for automatic zero signal Voltage output 0 to 10 V, power output 4 to 20 ma Very good repeatability Measurement range from ±100με up to ±750με Page 5.6 Type 22DJ For cyclical measurements; with integrated amplifier CANopen Excellent signal to noise ratio High sensitivity Page Operating method of DSRT strain links: The present structure strain (of the measurement object) between the two screw supports is mechanically transferred to the strain sensor. The transfer takes place because of the strain transforming principle. This means, strain signal overload from 200% up to 400% and good signal/noise proportion will be reached. Upon request the integrated amplifier may be adjusted to diverse applications. DSRT strain links are especially suited to measurement on rigid structures appearing on presses, injection moulding machines and other cyclical applications. The transmitters (with integrated amplifier) may also be used for force and weight measuring on structures
58 Strain Link without Amplifier DSRT 22DA Features Strain link without amplifier Static and dynamic applications Measuring range ±250 resp. ±750 με S/G Data Strain gage type Bridge resistance Foil strain gage Full bridge 350 Ω Mechanical Data Material - Housing chemically nickel-plated - Cover Electrical connection 5 pin (M12 x 1) Sensor stiffness 1 mechanic 0,2 mechanic Overload capability 200 % Environmental Conditions Operating temp.range C Storage temp. range C Vibration EN Hz 10 g (Amplitude ±0,75 mm, Hz) Random IEC Hz, 0,1 g 2 /Hz Schock IEC g / 11 ms Protection class IP 67 Delivery Contents Mounting screws 4 pcs. M6 x 25 strength class 12.9 Order Code DSRT 22DA-S Measuring range 250 µε 0750 Measuring range 750 µε Electrical Data Measuring range ±250 µe...±750 µe (1 µe = 0,001 mm/m resp. 1 µe equals 0,001 mm strain per meter) Sensitivity 1, µε 0, µε Sensitivity tolerance typical ± 2 % Linearity < 0,5% FSR Hysteresis < 0,5% FSR Repeatability < 0,1% FSR (cycle to cycle) Accessories (not included in delivery) Series 713 Connector female, 5 pin, part no Connector female with cable, 5 pin ESG 34CH0200G 5-pin (shielded) 2 m, PUR, (Part No ) ESG 34CH0500G 5-pin (shielded) 5 m, PUR, (Part No ) ESG 34CH1000G 5-pin (shielded) 10 m, PUR, (Part No ) 5.4
59 DSRT 22DA Dimensions (mm) Electrical Connections N8 N ( ) r 0.1 M6x25 10, ,5 ±0.1 M 12 x Pin Signal 1 E+ 2 S- 3 E- 4 S+ 5 n.c. Housing Shield ε 6 53 ± Control 5 E+ S- S+ E
60 Strain Link with Amplifier DSRT 22DD Features Static and dynamic applications Integrated reset switch for automatic zero point setting Measuring range ±100 up to ±750 με, extension and compression Voltage output S/G Data Strain gage type Mechanical Data Environmental Conditions Delivery Contents Foil strain gage Material - Housing chemically nickel-plated - Cover Electrical connection 5 pin (M12 x 1) Application position any Sensor stiffness 1 0,2 Operating temp.range C Storage temp. range C EMC EN EN Vibration IEC Hz 10 g (amplitude ±0,75 mm, Hz) Random IEC Hz, 0,1 g 2 /Hz Shock IEC Protection class IP g / 11 ms Mounting screws 4 pcs. M6 x 25 strength class 12.9 Order Code DSRT 22DD-S5- Electrical Data Measuring range ±100 µe...±750 µe (1 µe = 0,001 mm/m resp. 1 µe equals 0,001 mm strain per meter) Output signal ±10 VDC (max. ±12 VDC) Characteristic curve < 1,0% FS deviation Linearity < 0,5% FS Hysteresis < 0,5% FS Repeatability < 0,1% FS Supply voltage range VDC Taring "activ High" Low < 1 VDC High VDC Accessories (not included in delivery) Series 713 Connector female, control side, 5-pin, Part No Connector female with cable, control side, 5-pin ESG 34CH0200G 5-pin (shielded) 2 m, PUR, (Part No ) ESG 34CH0500G 5-pin (shielded) 5 m, PUR, (Part No ) ESG 34CH1000G 5-pin (shielded) 10 m, PUR, (Part No ) 0100 Measuring range 100 µε 0250 Measuring range 250 µε 0350 Measuring range 350 µε 0500 Measuring range 500 µε 0750 Measuring range 750 µε 5.6
61 DSRT 22DD Dimensions (mm) Electrical Connections N8 N ( ) r 0.1 M6x25 10,2 M 12 x Pin Signal 1 +Vs 2 -V OUT 3 GND 4 +V OUT 5 Reset Housing 14,5 ±0.1 Shield ε ± Control Reset Function 5 DSRT Controller V OUT e Reset t 1 t 2 t 3 Output signal Input signal Reset input (active high) Reset delay (< 0,3 ms) Reset time (< 5 ms) Reset impulse (> 1 ms) 5.7
62 Strain Link with CANopen DSRT 22DJ Features Digital linearization Decoupling of torsion and bending Taring function with PDO- or SDO-command Measuring range ±100 up to ±750 µε, extension and compression S/G Data Strain gage type Mechanical Data Foil strain gage Material - Housing chemically nickel-plated - Cover Electrical connection 5 pin (M12 x 1) Application position Environmental Conditions Operating temp. range C Storage temp. range C EMC EN EN Vibration IEC Hz 10 g (amplitude ±0,75 mm, Hz) Random IEC Hz, 0,1 g 2 /Hz Shock IEC any Sensor stiffness 1 0,2 Protection class IP g / 11 ms Electrical Data Measuring range ±100 µe ±750 µe (1 µe = 0,001 mm/m resp. 1 µe equals 0,001 mm strain per meter) Output / Protocol CANopen DS404 Resolution 0,1 µε Measuring rate 1000 x / sec. Data format Fix points Total error < 0,5% FS at ambient temperature Hysteresis < 0,4% FS Repeatability < 0,1% FS Taring time < 9 ms Supply voltage range VDC Current draw < 60 ma Accessories (not included in delivery) Series 713 Connector female, control side, 5-pin, Part No Delivery Contents Mounting screws 4 pcs. M6 x 25 strength class 12.9 Order Code DSRT 22DJ-S Measuring range 100 µε 0250 Measuring range 250 µε 0500 Measuring range 500 µε 0750 Measuring range 750 µε Connector female with cable, control side, 5-pin ESG 34CH0200G 5-pin (shielded) 2 m, PUR, (Part No ) ESG 34CH0500G 5-pin (shielded) 5 m, PUR, (Part No ) ESG 34CH1000G 5-pin (shielded) 10 m, PUR, (Part No ) 5.8
63 DSRT 22DJ Dimensions (mm) Electrical Connections N8 N ( ) ,5 ±0.1 r 0.1 M6x25 ε 10,2 M 12 x Pin Signal 1 n.c. 2 +VS 3 GND 4 CANH 5 CANL Housing Shield 6 53 ± Supported Objects Temporal Course Object Description 1000 Device profile 1001 Error register 1002 Serial number 1003 Emergency history 1005 Sync ID 1008 Device description 1009 Hardware version 100A 1010 Store Software version 1011 Load default values 1017 Heartbeat 1018 Device identity 1400 Reception PDO1 parameter 1600 PDO 1 Mapping parameter 1800 Transmit PDO1 parameter 1801 Transmit PDO2 parameter 1802 Transmit PDO3 parameter 1A00 1A01 1A03 1. PDO Mapping 2. PDO Mapping 3. PDO Mapping 2000 Averaging time 2001 Auto zero store 2100 Baud rate 2101 Identification 6110 Sensor Type 6112 Operating mode 6125 Auto zero 6131 Process unit 6132 Decimal places 6150 Status of measurement 7130 Interrogate measured value (Process value) 7133 Delta Value 8 ms 1 ms Example ID Internal taring phase Identification Answer Reply Baumer sensor 201h 0 Receipt - PDO COB-ID = ID Transmit - PDO COB-ID = ID No further communication with Baumer sensor Transmit - PDO COB-ID = ID DLC First answer of strain link (Command realized) ID DLC Byte 1 381h 1 75h Control unit Inquiry Reply Second answer of strain link (Taring finished) ID DLC Byte 1 Byte 2 381h Error (Unstable signal) ID DLC Byte 1 Byte 2 381h 2 65h 72h Identification
64 5.10
65 Bridge Amplifier 6
66 Product Key Bridge Amplifier DABx The correct order code must be taken from the corresponding data sheet. DABU AD2T-FB-1.00 Product Description DAB = Bridge Amplifier Output Signal I = ma U = ±10 V Series MP4 = 1-Channel, in aluminum/plastic enclosure, for DIN-rail mounting, with display AD2 = 1-Channel, compact aluminum housing Method M = multifunctional for statical and cyclical applications T = for static and cyclic applications Connection S/G Bridge 2Q = 2 x 1/4 strain gage bridge, diagonal layout, 350 Ω FB = full bridge FC = selectable configuration, 350 Ω Sensitivity 0.50 = 0,50 mv/v at nominal output signal 1.00 = 1,00 mv/v at nominal output signal 1.25 = 1,25 mv/v at nominal output signal 2.00 = 2,00 mv/v at nominal output signal 0250 = 250 µε at nominal output signal 0500 = 500 µε at nominal output signal 1000 = 1000 µε at nominal output signal Bridge amplifiers for strain gage circuits convert the mv signals from the bridges (S/G full bridge or 2 x 1/4 S/G bridge) into standardized output signals (V or ma). The S/G amplifiers are configured to work with Baumer sensors
67 Summary Bridge Amplifier DABU AD2T-2Q Bridge amplifier for 2 x 1/4 S/G bridge Voltage output For cyclic applications with reset Protection class IP 65 Page 6.4 DABI AD2T-2Q Bridge amplifier for 2 x 1/4 S/G bridge Current output For cyclic applications with reset Protection class IP 65 Page 6.6 DABU AD2T-FB Bridge amplifier for S/G full bridge Voltage output For cyclic and static applications with reset Protection class IP 65 Page 6.8 DABI AD2T-FB Bridge amplifier for S/G full bridge Current output For cyclic and static applications with reset Protection class IP 65 Page DABx MP4M S/G amplifier, selectable configuration (2 x 1/4 S/G bridge and full bridge) Voltage or current output Peak value and two limit switches Enclosure for DIN rail installation Page
68 Bridge Amplifier for 2 x 1/4 Strain Gage Bridge DABU AD2T-2Q Features Industrial bridge amplifier for 2 x 1/4 S/G bridge For cyclical applications with reset function Voltage output Protection class IP 65 Electrical Data Output signal ±10 V calibrated (max. ±12 V) Characteristic curve < 0,2% deviation Supply voltage range VDC Current draw < 60 ma < VDC Bridge excitation approx. 9 VDC S/G bridge resistance 350 Ω (R C ) Output impedance 22 Ω Tare accuracy 0250 < 15 mv 0350 < 12 mv 0500 < 7 mv 1000 < 5 mv Reset input active 5-33 VDC < 2 ma inactive < 1 VDC Tare range ±6 mv/v Reset puls > 1 ms Reset settle time < 5 ms Frequency range (-3 db) 1'000 Hz Signal polarity Bipolar Noise ( khz) 0250 < 15 mv pp 0350 < 12 mv pp 0500 < 7,5 mv pp 1000 < 5 mv pp Order Code DABU AD2T-2Q Dimensions (mm) M12 x1 79 Delivery Contents 40 Mounting screw 2 pcs. M4 x 30 Gain µε = 0-10 V µε = 0-10 V µε = 0-10 V µε = 0-10 V 29 Accessories (not included in delivery) Series Connector female, control side, 5-pin, Part No Mechanical Data Control connection 5 pin male (Series 713) Sensor connection 4 pin female (Series 712) Enclosure aluminum anodised Environmental Conditions Operating temp. range C Specified temp. range C Storage temperature C Protection class IP M12 x 1 Connector female with cable, control side, 5-pin ESG 34CH0200G 5-pin (shielded) 2 m, PUR, (Part No ) ESG 34CH0500G 5-pin (shielded) 5 m, PUR, (Part No ) ESG 34CH1000G 5-pin (shielded) 10 m, PUR, (Part No )
69 DABU AD2T-2Q Electrical Connection Sensor side Series 712 Control side Series 713 S/G Bridge R C EXC.+ DMS S/G 2 Pin Signal 1 DMS 1 EXC.+ 2 DMS 1 SIG.- 3 DMS 2 SIG.+ 4 DMS 2 EXC.- Pin number Signal 1 +Vs 2 -VOUT 3 GND 4 +VOUT 5 Reset SIG.+ S/G DMS 11 R C EXC.- SIG.- Control Reset Function Transducer DABU Control Unit max. 10m max. 10m EXC V S 18-33VDC SIG GND SIG V OUT 6 EXC V OUT R L ±10V U 5 Reset 5-33 VDC Potential equalisation V OUT ε Reset t 1 t 2 t 3 Output signal Input signal Reset input (active high) Reset delay (< 0,3 ms) Reset time (< 5 ms) Reset impuls (> 1 ms) 6.5
70 Bridge Amplifier for 2 x 1/4 Strain Gage Bridge DABI AD2T-2Q Features Industrial bridge amplifier for 2 x 1/4 S/G bridge For cyclical and static applications with reset function Current output Protection class IP 65 Electrical Data Output signal 4-20 ma calibrated Characteristic curve 0250 < 0,5% deviation 0500 < 0,25% 1000 < 0,2% Supply voltage range VDC Current draw < 90 ma < VDC Bridge excitation approx. 9 VDC S/G bridge resistance 350 Ω Burden < 400 Ω Tare accuracy 0250 < 30 µa 0500 < 20 µa 1000 < 16 µa Reset input active 5-33 VDC < 2 ma inactive < 1 VDC Tare range ±6 mv/v Reset puls > 1 ms Reset settle time < 5 ms Frequency range (-3 db) 1'000 Hz Noise ( khz) 0250 < 30 µa pp 0500 < 20 µa pp 1000 < 16 µa pp Mechanical Data Control connection 5 pin male (Series 713) Sensor connection 4 pin female (Series 712) Enclosure aluminum anodised Environmental Conditions Operating temp. range C Specified temp. range C Storage temperature C Protection class IP 65 EMC EN Immunity EN Emission Order Code DABI AD2T-2Q /C M12 x1 79 Gain µε = 4-20 ma µε = 4-20 ma µε = 4-20 ma /C Tension leads to a positive output signal Dimensions (mm) Delivery Contents 40 Mounting screw 2 pcs. M4 x Accessories (not included in delivery) Series 713 Connector female with cable, control side, 5-pin Connector female, control side, 5-pin, Part No max. cable length 20 m M12 x 1 ESG 34CH0200G 5-pin (shielded) 2 m, PUR, (Part No ) ESG 34CH0500G 5-pin (shielded) 5 m, PUR, (Part No ) ESG 34CH1000G 5-pin (shielded) 10 m, PUR, (Part No ) 6.6
71 DABI AD2T-2Q Electrical Connection Sensor side Series 712 Control side Series 713 S/G Bridge R C EXC.+ DMS 1 Pin Signal 1 DMS 1 EXC.+ 2 DMS 2 SIG.- 3 DMS 3 SIG.+ 4 DMS 4 EXC.- Pin number Signal 1 +Vs 2 n.c. 3 GND 4 +IOUT 5 Reset SIG.+ DMS 2 R C EXC.- SIG.- Control Reset Function Transducer DABI Control Unit max. 10m EXC+ 1 SIG- SIG+ EXC ε I max. 20m 1 +V s 14-33VDC 3 GND 2 R L 4 +I OUT 4-20mA 5 Reset 5-33 VDC 6 Potential equalisation I OUT mv/v Reset t 1 t 2 t 3 Output signal Input signal Reset input (active high) Reset delay (< 0,3 ms) Reset time (< 5 ms) Reset impuls (> 1 ms) 6.7
72 Bridge Amplifier for Strain Gage Full Bridge DABU AD2T-FB Features Industrial bridge amplifier for S/G full bridge For cyclical and static applications with reset function Voltage output Protection class IP 65 Analog signal path Electrical Data Output signal ±10 V calibrated (max. ±12 V) Characteristic curve < 0,2% deviation Supply voltage range VDC Current draw < 60 ma < VDC Bridge excitation approx. 7 VDC S/G bridge resistance 350 Ω (R C ) Output impedance 22 Ω Tare accuracy 0.25 < 15 mv 0.50 < 10 mv 1.00 < 5 mv 2.00 < 5 mv Reset input active 5-33 VDC < 2 ma inactive < 1 VDC Tare range ±6 mv/v Reset puls > 1 ms Reset settle time < 5 ms Frequency range (-3 db) 1'000 Hz Signal polarity Bipolar Noise ( khz) 0.25 < 15 mv pp 0.50 < 7,5 mv pp 1.00 < 5 mv pp 2.00 < 5 mv pp Mechanical Data Control connection 5 pin male (Series 713) Sensor connection 4 pin female (Series 712) Order Code DABU AD2T-FB Dimensions (mm) Enclosure aluminum anodised Connector female with cable, control side, 5-pin Environmental Conditions ESG 34CH0200G 5-pin (shielded) 2 m, PUR, Operating temp. range C (Part No ) Specified temp. range C ESG 34CH0500G 5-pin (shielded) 5 m, PUR, (Part No ) Storage temperature C ESG 34CH1000G 5-pin (shielded) 10 m, PUR, Protection class IP 65 (Part No ) EMC EN Immunity EN Emission M12 x1 79 Delivery Contents 40 Mounting screw 2 pcs. M4 x 30 Gain ,50 mv/v = 0-10 V ,00 mv/v = 0-10 V ,25 mv/v = 0-10 V ,00 mv/v = 0-10 V M12 x 1 29 Accessories (not included in delivery) Series Connector female, control side, 5-pin, Part No max. cable length 10 m
73 DABU AD2T-FB Electrical Connection Sensor side Series 712 Control side Series 713 S/G Bridge EXC Pin Signal 1 Full bridge EXC.+ 2 Full bridge SIG.- 3 Full bridge SIG.+ 4 Full bridge EXC.- Pin number Signal 1 +Vs 2 -VOUT 3 GND 4 +VOUT 5 Reset SIG.+ EXC.- SIG.- Control Reset Function Transducer DABU Control Unit max. 10m mv/v max. 10m EXC V S 18-33VDC SIG GND SIG V OUT 6 EXC V OUT R L ±10V U 5 Reset 5-33 VDC Potential equalisation V OUT mv/v Reset t 1 t 2 t 3 Output signal Input signal Reset input (active high) Reset delay (< 0,3 ms) Reset time (< 5 ms) Reset impuls (> 1 ms) 6.9
74 Bridge Amplifier for Strain Gage Full Bridge DABI AD2T-FB Features Industrial bridge amplifier for S/G full bridge For cyclical and static applications with reset function Current output Protection class IP 65 Analog signal path Electrical Data Output signal 4-20 ma calibrated Characteristic curve 0.25 < 0,5% 1.00 < 0,2% deviation 0.50 < 0,25% 2.00 < 0,2% Supply voltage range VDC Current draw < 90 ma < VDC Bridge excitation approx. 7 VDC S/G bridge resistance 350 Ω Burden < 500 Ω Tare accuracy 0.25 < 30 µa 0.50 < 20 µa 1.00 < 16 µa 2.00 < 16 µa Reset input active 5-33 VDC < 2 ma inactive < 1 VDC Tare range ±6 mv/v Reset puls > 1 ms Reset settle time < 5 ms Frequency range (-3 db) 1'000 Hz Noise ( khz) 0.25 < 15 µa pp 0.50 < 7,5 µa pp 1.00 < 5 µa pp 2.00 < 5 µa pp Mechanical Data Control connection 5 pin male (Series 713) Sensor connection 4 pin female (Series 712) Enclosure aluminum anodised Order Code DABI AD2T-FB Dimensions (mm) Environmental Conditions ESG 34CH0200G 5-pin (shielded) 2 m, PUR, (Part No ) Operating temp. range C ESG 34CH0500G 5-pin (shielded) 5 m, PUR, Specified temp. range C (Part No ) Storage temperature C ESG 34CH1000G 5-pin (shielded) 10 m, PUR, Protection class IP 65 (Part No ) EMC EN Immunity EN Emission M12 x1 Delivery Contents 79 Gain ,50 mv/v = 4-20 ma ,00 mv/v = 4-20 ma ,00 mv/v = 4-20 ma 40 Mounting screw 2 pcs. M4 x 30 M12 x 1 29 Accessories (not included in delivery) Series 713 Connector female with cable, control side, 5-pin Connector female, control side, 5-pin, Part No max. cable length 20 m
75 DABI AD2T-FB Electrical Connection Sensor side Series 712 Control side Series 713 S/G Bridge EXC Pin Signal 1 Full bridge EXC.+ 2 Full bridge SIG.- 3 Full bridge SIG.+ 4 Full bridge EXC.- Pin number Signal 1 +Vs 2 n.c. 3 GND 4 +IOUT 5 Reset SIG.+ EXC.- SIG.- Control Reset Function Transducer DABI Control Unit max. 10m max. 20m mv/v EXC V S 14-33VDC 2 3 GND SIG.- SIG.+ 3 EXC.- 4 I 2 R L 4 +I OUT 4-20mA 5 Reset 5-33 VDC 6 Potential equalisation I OUT mv/v Reset t 1 t 2 t 3 Output signal Input signal Reset input (active high) Reset delay (< 0,3 ms) Reset time (< 5 ms) Reset impuls (> 1 ms)
76 Bridge Amplifier, Selectable Configuration DABU MP4M Features S/G Bridge amplifier Selectable bridge configuration Limit switches with switching output Peak value Double-line display Voltage output Digital signal path Electrical Data Output signal Resolution Measuring accuracy Supply voltage range Current consumption Bridge excitation Bridge completion resistors Zero reset active Reset input galvanically separated Taring range Reset pulse Holding time Reset/operate offset Scanning rate Frequency range (3 db) Display refresh rate Switching hysteresis limit switches Max. load limit switches Signal polarity ±10 V calibrated load > 10 kω < 0,035% FS < 0,15% v.e VDC < 120 ma 5 VDC 350 Ω < ±10 mv active 5-33 VDC inactive <1 VDC ±6 mv/v < 1 ms < 5 ms < ±10 mv > 1 ms 300 Hz 2/sec < 0,5% FS max. 50 ma selectable Mechanical Data Control connection Sensor connection Shield connection Enclosure material Environmental Conditions DABU MP4M-FC- 13 pin terminal block 13 pin terminal block 2 pin terminal block aluminum/plastic Operating temp. range C Storage temperature C Protection class IP 40 Order Code Gain 0.50 =0,50 mv/v= 0-10 V 0.75 =0,75 mv/v= 0-10 V 1.00 =1,00 mv/v= 0-10 V 1.25 =1,25 mv/v= 0-10 V 2.00 =2,00 mv/v= 0-10 V Delivery Contents Clamping clip for ground connection
77 DABU MP4M Dimensions (mm) 45,5 75,5 72,5 31 Supporting rail TS 35 (DIN EN TH35) Electrical Connections 6 Pin assignment sensor side Pin assignment control side Pin Signal Description 1 +E +bridge excitation 2 +E +bridge excitation 3 +E' bridge to completion resistor 4 n.c. 5 n.c. 6 +S + signal input 7 -S signal input 8 n.c. 9 -E' bridge to completion resistor 10 -E' bridge to completion resistor 11 -E bridge excitation 12 -E bridge excitation 13 Shield Pin Signal Description 1 +Vs +supply voltage 2 Vout1/Iout 1 output signal 3 GND -supply voltage 4 Vout2/Iout2 analog output (peak value) 5 GND signal reference 6 switch S1 output 1 7 switch S2 output 2 8 Reset Taring of output signal 9 GND signal reference 10 Comm_Logic logical reference 11 Mode_0 mode 0 12 Mode_1 mode 1 13 Error output
78 Bridge Amplifier, Selectable Configuration DABU MP4M Electrical Connections E+ 1,2 E+' 3 S+ 6 S- 7 E-' 9 E-' 10 E- 11,12 +5V D-Pot 12bit A D +5V LCD up DAC 12bit DAC 12bit +Vs 1+Vs 3,5,9 GND 2 Vout/Iout (Signal) 4 Vout 2/Iout 2 (Peak) 13 Error 7Switch 2 6Switch 1 Shield 13 Error LED LED1 LED2 red/green green green 3 8 Reset 11 Mode_0 12 Mode_1 10 Com_Logic Shield Shield S/G Bridge 2 x 1/4-bridge (diagonal) half bridge full bridge sensor side control side sensor side control side sensor side control side E+ 1 E+ 1 E+ 1 E+ 2 E+ 2 E+' 3 E+' 3 S- 7 S+ 6 S- 7 E-' 10 E- 11 E- 12 S+ 6 S- 7 E-' 9 E- 11 E- 12 S+ 6 E
79 DABU MP4M Reset Function V Peak Signal U t Reset Measure t1 t2 t V Reset t 1 t 2 Output signal resp. peak signal Reset input (active high) Reset pulse (> 1 ms) Reset holding time after Reset-Pulse (< 5 ms) Control Element 6 DIP-switch 1 LED 3 DIP-switch 2 display connector 3 connector 1 LED switch connector 2 DIP-Switch 1 Connector 1 LED 3 LED DIP-Switch 2 Switch Connector 3 Connector 2 Display Selection of display Connection sensor side Error display Limit value (active/inactive) Reset (active/inactive); signal polarity For limit value adjustment Shield connection Control side connection Double-line LC-display with back ground lighting
80 6.16
81 Display box 7
82 Product Key Display box The correct order code must be taken from the corresponding data sheet. Display box Product Description DDB = Display box DDBF 2-SC Sensor Input F = Free Configuration Number of Channels 2 = 2-channels 4 = 4-channels Change-Over Displays SC = Display box for Strain Rings 7.2
83 Summary Display box DDBF 2-SC 2-channel display box for strain rings DSRC Metered value display of every sensor, Average and peak value of both sensors Bending measurement through strain gauge display Including analysis software InspectMaster Page 7.4 DDBF 4-SC 4-channel display box for strain rings DSRC Measurement display of every active channel Display of peak value, average value or sum Including analysis software InspectMaster Page
84 Display box, 2-channel DDBF 2-SC Features 2-channel display box for strain rings DSRC Measurement value of each sensor, Average and peak value of both sensors Bending measurement by individual S/G display A/C or Battery operation Display in µe, kn, t 2 analog outputs Reset with keypad or InspectMaster Electrical Data Connection Display Measuring range Resolution 1 µε Characteristic < 0,25% FS curve deviation Reset/operate offset < ±0,1% FS Bridge completion 350 Ω resistors Rc Reset 2 channels for 2 x 1/4 S/G bridge (350 Ω) Sensor A or B peak value, average value ±1000 µε (calibrated) Zeroing is performed by pressing the reset button or by the software InspectMaster Measuring rate InspectMaster/ analog output 250/sec Analog output ±1 V calibrated at ±1000 µε Display refresh rate 2/sec Battery Maintenance-free Li-Ion battery USB connection USB 2.0, type B Order Code DDBF 2-SC Delivery Contents Display box Power adapter ( VAC) Software InspectMaster USB connecting cable Ground connection cable with clip Mechanical Data Sensor connection 4 pin Binder (series 712) Enclosure Aluminum, lacquered Environmental Conditions Operating temp. range C Storage temperature C Protection class IP
85 DDBF 2-SC Dimensions (mm) View Connector Side 110 Analog OUT2 Analog OUT1 CH A CH B Analog Analog CH A CH B CH C CH D OUT1 OUT2 35 Displa ybox DDBF Error RESET disable View Bottom Side, under the top cover 212 USB-Connection Connection for power adapter, VDC F1 F2 F3 ON/OFF Esc Enter 100 Prog. RESET Display battery charge status 85 Electrical Connections Sensor connection S/G Bridge Pin Signal 1 S/G 1 EXC,+ 2 S/G 1 SIG.- 3 S/G 2 EXC.+ 4 S/G 2 SIG.- DMS 1 / S/G 1 DMS 2 / S/G 2 DDBF R R R EXC.+ EXC.+ 7 R 4 R R Pro Kanal / Per channel Analysis Software InspectMaster Functions: - Display in µe, N, kn, t - Display of deviation of tie bar load distribution in % - Cycle function with auto reset mode - Display of graphs - Saving of measured data - Export function (Text file may be exported and processed in Excel) Requirements: - PC with Windows, 2000, NT, XP minimum 500 MHz and USB interface required 7.5
86 Display box, 4-channel DDBF 4-SC Features 4-channel display box for strain rings DSRC Contemporaneous measurement and display of 4 channels A/C or Battery operation Display in µe, kn, t 2 analog outputs Reset with keypad or InspectMaster Electrical Data Connection 4 channels for 2 x 1/4 S/G bridge (350 Ω) Display Average / peak value or sum / peak value of the activated channels Measuring range ±1000 µe (calibrated) Resolution 1 µe Characteristic < 0,25% FS curve deviation Reset/operate offset < ±0,1% FS Bridge completion 350 Ω resistors Rc Reset Zeroing is performed by pressing the reset button or by the software InspectMaster Measuring rate InspectMaster/ analog output 250/sec Analog output ±1 V calibrated at ±1000 µe Display refresh rate 2/sec Battery Maintenance-free Li-Ion battery USB connection USB 2.0, type B Order Code DDBF 4-SC Delivery Contents Display box Power adapter ( VAC) Software InspectMaster USB connecting cable Ground connection cable with clip Mechanical Data Sensor connection 4 pin Binder (series 712) Enclosure Aluminum, lacquered Environmental Conditions Operating temp. range C Storage temperature C Protection class IP
87 DDBF 4-SC Dimensions (mm) View Connector Side 110 Analog OUT2 Analog OUT1 CH A CH C CH B CH D Analog Analog CH A CH B CH C CH D OUT1 OUT2 35 Displa ybox DDBF Error RESET disable View Bottom Side, under the top cover 212 USB-Connection Connection for power adapter, VDC F1 F2 F3 ON/OFF Esc Enter 100 Prog. RESET Display battery charge status 85 Electrical Connections Sensor connection Bridge configuration per connector Pin Signal 1 S/G 1 EXC,+ 2 S/G 1 SIG.- 3 S/G 2 SIG.+ 4 S/G 2 EXC.- DMS 1 / S/G 1 DDBF 1 2 R R EXC.+ 7 DMS 2 / S/G Pro Kanal / Per channel Analysis Software InspectMaster Functions: - Display in µe, N, kn, t - Display of deviation of tie bar load distribution in % - Cycle function with auto reset mode - Display of graphs - Saving of measured data - Export function (Text file may be exported and processed in Excel) Requirements: - PC with Windows, 2000, NT, XP minimum 500 MHz and USB interface required 7.7
88 7.8
89 Piezo Electric Sensors 8
90 Product Key Piezo Electric Force and Strain Sensors The correct order form must be taken from the corresponding data sheet. Force sensors Product Description DLPP = Piezo electric force sensor DLPP 6MO Series 8MO = Micro sensor, 0,8 cable 6MO = Miniature sensor, connector with thread M4 x 0,35 7MO = Circular shape, connector with thread M4 x 0,35 4MO = Circular shape, connector with thread UNF Nom. Capacity 0.3 = 250 N 2.5 = 2,5 kn 010 = 10 kn 030 = 30 kn Nominal Sensitivity Example 4.4 = 4,4 pc/n 8.2
91 Summary Piezo Electric Force and Strain Sensors DLPP 8MO Quartz micro force sensor Capacity N 0,8 m cable Sensor diameter 3,5 mm Page 8.4 DLPP 6MO Quartz miniature force sensor Capacity ,5 kn Connector thread M4 x 0,35 Sensor diameter 6 mm Page 8.5 DLPP 7MO Quartz force sensor Capacity kn Connector thread M4 x 0,35 Sensor diameter 12,6 mm Page 8.6 DLPP 4MO Quartz force sensor Capacity kn Connector thread UNF Sensor diameter 25 mm Page
92 Cavity force sensor N DLPP 8MO Features 250 N quartz micro force sensor To measure dynamic forces Welded construction available with or without connector Technical Data Dimensions (mm) Method Measuring range Max. allowable load Nom. sensitivity Linearity Capacitance w/o cable Insulation resistance at 20 C Insulation resistance at 150 C Piezo electric; quartz N 300 N > =10 pc/n < ±2% v.e. < 50 pf > Ω > Ω 3, ø 4,69 ±0,01 6,2 +0,2-0,4 Mechanical Data Delivery Contents Material Stainless steel Calibration sheet Environmental Conditions Operating temp. range C Storage temperature C Accessories Mounting plate and screws for MF Typ DZPC HPFC Mounting plate Fischer connector (for DLPP 8MO /MF) Order Code DLPP 8MO DLPP 8MO /MF (cable version) 8.4
93 Cavity force sensor 2,5 kn DLPP 6MO Features 2,5 kn miniature quartz force sensor Extremely small size To measure dynamic forces Welded construction With connector Technical Data Dimensions (mm) Method Measuring range Max. allowable load Nom. sensitivity Linearity Capacitance w/o cable Insulation resistance at 20 C Insulation resistance at 150 C Piezo electric; quartz ,5 kn 3 kn -4,4 pc/n < 1% FS < 50 pf > Ω > Ω M 4x ø M 5 13,4 14 Mechanical Data Connector thread M4 x 0,35 Material Stainless steel Delivery Contents Calibration sheet 8 Environmental Conditions Operating temp. range C Storage temperature C Protection incl. cable IP 65 Accessories Connecting Cable DZCC xxxx-st-mf DZCC xxxx-ht-mf DZCC xxxx-st-mb Order Code DLPP 6MO
94 Cavity force sensor 10 kn DLPP 7MO Features 10 kn quartz force sensor Small size To measure dynamic and quasi static forces Welded construction With connector Technical Data Dimensions (mm) Method Measuring range Max. allowable load Nom. sensitivity Linearity Capacitance w/o cable Insulation resistance at 20 C Insulation resistance at 150 C Piezo electric; quartz kn 12 kn -2,2 pc/n < 1% FS < 50 pf > Ω > Ω M 5 14,3 14 M 2,5 ø 12,6 h ,2 9, ,3 14 Mechanical Data Connector thread M4 x 0,35 Material Stainless steel Delivery Contents Calibration sheet Environmental Conditions Operating temp. range C Storage temperature C Protection incl. cable IP 65 Accessories Connecting Cable DZCC xxxx-st-mf DZCC xxxx-ht-mf DZCC xxxx-st-mb Order Code DLPP 7MO
95 Cavity force sensor 30 kn DLPP 4MO Features 30 kn quartz force sensor Compact size To measure dynamic and quasi static forces Welded construction With connector Technical Data Dimensions (mm) Method Measuring range Max. allowable load Nom. sensitivity Linearity Capacitance w/o cable Insulation resistance at 20 C Insulation resistance at 150 C Piezo electric; quartz kn 36 kn -4,4 pc/n < 1% FS < 50 pf > Ω > Ω 35,5 15 ø UNF ø 25 9, ø 7 Mechanical Data Connector thread UNF Material Stainless steel Delivery Contents Calibration sheet 8 Environmental Conditions Operating temp. range C Storage temperature C Protection incl. cable IP 65 Accessories Connecting Cable DZCC xxxx-78-ub Order Code DLPP 4MO
96 Product Key Cavity Pressure Sensors The correct order description must be taken from the corresponding data sheet. Product Description DPPC = Cavity pressure sensor DPPC DS /CS1 Method D = Direct cavity pressure measurement Version S = Standard Size 02.5 = 2,5 mm diameter sensor front 04.0 = 4 mm diameter sensor front Nominal Sensitivity For direct cavity pressure measurement in pc/bar For indirect cavity pressure measurement in pc/n 2.0 = 2 pc/bar 5.0 = 5 pc/bar 9.4 = 9,4 pc/bar Options /CS1 = Uniform sensitivity ± 1% /TP = Rotation prevention 8.8
97 Summary Cavity Pressure Sensors DPPC DS02.5 Cavity pressure sensor for direct measurement Capacity bar Connector thread M4 x 0,35 Sensor diameter 2,5 mm Page 8.10 DPPC DS04.0 Cavity pressure sensor for direct measurement Capacity bar Connector thread M4 x 0,35 Sensor diameter 4 mm Page
98 Cavity Pressure Sensor 2000 bar DPPC DS02.5 Features For direct measuring Measuring range bar Connector thread M4 x 0,35 Sensor diameter 2,5 mm Technical Data Dimensions (mm) Method Range Overload Nom. sensitivity Linearity Natural frequency Insulation resistance at 20 C Insulation resistance at 200 C Piezo electric; quartz bar 2500 bar -2,0 pc/bar < 1% FS > 80 khz > Ω > Ω max ± ø M 5 M 4x0,35 ø ,5 f7 Mechanical Data Connector thread M4 x 0,35 Material enclosure Stainless steel Delivery Contents Special nut DZPC MN04 Calibration sheet Environmental Conditions Operating temp. range C Storage temperature C Melt temperature < +400 C (at sensor front side) Protection incl. connector IP 65 Order Code DPPC DS / Option TP = Turning protection
99 DPPC DS02.5 Mounting Dimensions X max. R 0,05 0,3 30 free of burrs 0, min. ø 10 M8 x 0,75 ø 7,25 0,05 min. 32 0,01 A Mounting with Mounting with special nut spacer tube min. ø 7,2 32 min. 44 ø 6 x 10 ø 2,5 H7 A X Accessories Sensor Cable Mounting Accessories Description 8 DZCC xxxx-st-mf DZCC xxxx-ht-mf DZPC MN04 DZPC MWPT DZPC MT04 Special nut Mounting wrench Spacer tube
100 Cavity Pressure Sensor 2000 bar DPPC DS04.0 Features For direct measuring Measuring range bar Connector thread M4 x 0,35 Sensor diameter 4 mm Technical Data Dimensions (mm) Method Range Overload Piezo electric; quartz bar 2500 bar Nom. sensitivity DPPC DS ,0 pc/bar ± 2% DPPC DS ,4 pc/bar ± 2% DPPC DS /CS -9,4 pc/bar ± 1% Linearity Natural frequency Insulation resistance at 20 C Insulation resistance at 200 C < 1% FS > 100 khz >10 12 Ω >10 11 Ω max. 29 8±0,05 5 M 5 M 4 x 0,35 ø ø 4f ,1 Mechanical Data Connector thread M4 x 0,35 Material enclosure Stainless steel Delivery Contents Special nut DZPC MN04 Calibration sheet Environmental Conditions Operating temp. range C Storage temperature C Melt temperature < +400 C (at sensor front side) Protection incl. connector IP 65 Order Code DPPC DS04.0- / Option TP = Turning protection CS1 = Uniform sensitivity 1% Nominal sensitivity 5.0 = -5,0 pc/bar 9.4 = -9,4 pc/bar
101 DPPC DS04.0 Mounting Dimensions X max. R 0,05 0,2-0,3 30 free of burrs min. ø 10 M8 x 0,75 ø 7,25 0,05 Mounting with special nut min. ø 7,2 Mounting with spacer tube ø 6 x min. 28 0,01 A 28 min ø 4 H7 A X Accessories 8 Sensor Cable DZCC xxxx-st-mf DZCC xxxx-ht-mf Mounting Accessories DZPC MN04 DZPC MWPT DZPC MT04 Description Special nut Mounting wrench Spacer tube
102 Summary Accessories and Sensors , 6 9, 10 Pos. Mounting Accessories Type 1 Mounting equipment Fischer connector DZPC HPFC 2 Mounting wrench DZPC MWPT 3 Special nut for 2,5 / 4 mm cavity pressure sensor DZPC MN04 4 Spacer tube for 2,5 / 4 mm cavity pressure sensor DZPC MT04 Pos. Cable Type 5 Sensor cable C M4 x 0,35 - Fischer DZCC... -ST-MF 6 Sensor cable C M4 x 0,35 - Fischer DZCC... -HT-MF 7 Sensor cable M4 x 0,35 - BNC DZCC... -ST-MB 8 Sensor cable UNF BNC DZCC UB 9 Connecting cable Fischer - BNC DZCC FB 10 Connecting cable Fischer - BNC with protecting tube DZCC... -HT-FB Pos. Sensors Type 11 Cavity pressure sensor ø 2,5 mm DPPC DS Cavity pressure sensor ø 4,0 mm DPPC DS04.0-x.x 13 Miniature force sensor 2,5 kn DLPP 6MO Force sensor 10 kn DLPP 7MO Force sensor 30 kn DLPP 4MO
103 DZPC MWPT 9,9 3,6 DZPC MN04 DZPC MT04 9, ,5 M8 x0,75 3,6 Mounting Accessories Mounting wrench for DPPC DS02.5 DPPC DS04.0 DZPC HPFC Mounting plate Fischer connector ø 9,2 ø ,5 SW ,5 ø 1 M4 x 6 DIN Mat.: Mat.: Special nut for DPPC DS02.5 DPPC DS04.5 Spacer tube for DPPC DS02.5 (MT04) DPPC DS04.0 (MT04) Mat.: ±0,05 5,1 ø 3,6 13,2 50 Mat.: ø 8 13,5 3,4 ø
104 Cables DZCC Sensor Cable DZCC...- ST-MF L [mm] Order code 200 DZCC 0200-ST-MF 400 DZCC 0400-ST-MF 600 DZCC 0600-ST-MF 1000 DZCC 1000-ST-MF. Custom length Technical data Cable Color Impedance Cable-ø Bending radius Operating temp. range DZCC xxxx-st-mf Coax, Low Noise, PTFE/PFA blue 50 Ω 2 mm R C Connector M4 x 0, ø M5 L 10 ø 35 x0,5 M9 Delivery contents Mounting plate Fischer connector DZPC HPFC Connector Fischer Type KE 102 A014 Sensor Cable DZCC...- HT-MF L [mm] Order code 200 DZCC 0200-HT-MF 400 DZCC 0400-HT-MF 600 DZCC 0600-HT-MF 1000 DZCC 1000-HT-MF Custom length DZCC xxxx-ht-mf Technical data Cable Color Impedance Cable-ø Bending radius Operating temp. range Coax, Low Noise, PTFE/PFA steel sheathed 50 Ω 2, 4 mm R C Connector M4 x 0, M5 L ø ø 35 x0,5 M9 Delivery contents Mounting plate Fischer connector DZPC HPFC Connector Fischer Type KE 102 A014 Sensor Cable DZCC...- ST-MB L [mm] Order code 1000 DZCC 1000-ST-MB 2000 DZCC 2000-ST-MB Custom length DZCC xxxx-st-mb Connector Connector Technical data Cable Color Impedance Cable-ø Bending radius Operating temp. range Coax, Low Noise, PTFE/ PFA blue 50 Ω 1,9 mm R C M4 x 0,35 14 L 26 BNC
105 Sensor Cable DZCC UB L [mm] Order code 1000 DZCC UB 2000 DZCC UB 3000 DZCC UB Tailor made DZCC xxxx-78-ub Connector L Connector Technical data Cable Color Impedance Cable-ø Bending radius Operating temp. range Coax 178 RG brown 50 Ω 1,8 mm R C UNF BNC Connecting Cable Technical data Cable Color Impedance Cable-ø Bending radius Operating temp. range Connecting Cable DZCC...-HT-FB L [mm] Order code 2000 DZCC 2000-HT-FB 4000 DZCC 4000-HT-FB 5000 DZCC 5000-HT-FB Custom length DZCC xxxx-ht-fb Technical data Cable DZCC FB L [mm] Order code 2000 DZCC FB 4000 DZCC FB 5000 DZCC FB Custom length DZCC xxxx-04-fb Triax, Low Noise, PTFE/PFA transparent 50 Ω 3,4 mm R C Triax, Low Noise, PTFE, PFA metal sheath 50 Ω 5 mm R30 Color Impedance Cable-ø Bending radius Operating temp. range C Connector Fischer Type S 102 A014 Fischer Type S 102 A014 Connector L L Connector BNC BNC Connector 8
106 8.22
107 Charge Amplifiers 9
108 Product Key Charge Amplifiers The correct order code must be taken from the corresponding data sheet. Charge Amplifiers Product Description DAC = Charge Amplifier DACU K0BS Output U = Voltage output ±10 V Series 800 = 1 Analog output, 14 ranges 820 = 2 Analog outputs, 4 ranges every Smallest measuring range Example: 0.1 = 100 pc / 10 V Largest measuring range Example: 1K0 = 1'000'000 pc / 10 V Input Connection B = BNC Output Connection S = 25 Pin D-Sub 9.2
109 Summary Charge Amplifiers DACU 800 Charge amplifier for piezo electric sensors 14 selectable ranges Peak value 2 limit switches with switching outputs RS 232 interface Page 9.4 DACU 820 Charge amplifier for piezo electric strain sensors 2 analogue outputs 4 selectable ranges Peak value storage 2 limit switches with switching output RS 232 interface Page 9.8 Charge amplifiers convert the electrical charges (pc), which are emitted by piezo electric sensors, into a proportional output voltage. This output signal can then be further processed
110 Charge Amplifier DACU 800 Features Multi-range charge amplifier for industrial application 14 selectable ranges 13 fixed ranges 100 pc - 1'000'000 pc 1 variable range 100 pc - 1'000'000 pc Adjustable limit value with switching output Peak value RS 232 serial interface Electrical Data Voltage supply VDC Current draw < 70 ma Measuring range ± '000'000 pc Output signal ± 10 V Characteristic curve < 1% FS deviation Linearity < 0,02% FS Output offset < ± 5 mv Noise voltage < 5 mvpp (0,1 Hz khz) < 30 mvpp at 100 pc range Output impedance 10 Ω Reset operate offset electronically compensated Drift < 0,03 pc/s (2) Frequency range (-3 db) khz (1) Control input ± 5 V...± 45 V, galv. separated Switching output max. 45 V, max. 100 ma galv. separated 100 pc...1'000'000 pc; > 2 1'000'000 pc Order Code DACU K0BS Included Mounting screws 2 pcs. M4 x 16 Dimensions (mm) (2) DACU at least 30 min. attached to operational voltage All specifications at ambient temperature (23 C ±2 C) Mechanical Data Control connection Sensor connection Enclosure material 25 pin D-Sub BNC male Aluminum die cast Environmental Conditions Operating temp. range C Storage temperature C Protection class IP 40 EMC EN immunity EN emission 9.4
111 DACU 800 Electrical Connections D-Sub 25 Pin Function 1 Signal out 2 Peak out 3 Level 1 (In or Out) 4 Level 0 (In or Out) 5 Range 3 6 Range 2 7 Range 1 8 Range 0 9 Supply GND 10 +Supply 11 Code 2 12 Code 0 13 Code Supply + 14 Signal GND 15 Alarm 1 16 Alarm 0 17 RX 18 TX 19 Com Logic Input 20 Operate 21 80% Test 22 Supply GND 23 NC 24 Code 1 25 Com Logic Output (Alarm) Measuring Range Selection Range Measuring range pc/10v '000' ' ' ' ' ' ' ' ' ' ' '000' ' ' '000 Accessories Connecting cable with open end Control Elements L 50 9 Length(L) Order code 5 m DZCS 05/DACU 8 Range L0 L1 Adjustment of variable range Adjustment of value 1. The limit switch voltage can be set with the potentiometer and has to be measured at pin 4. Alternatively a voltage can be supplied as well. Adjustment limit value 2. ditto, pin 3 only 9.5
112 Charge Amplifier DACU 820 Features Multi-range charge amplifier for industrial application 4 selectable ranges channel 1 3 fixed ranges 100'000 pc - 500'000 pc 1 variable range 100'000 pc - 500'000 pc 4 fixed ranges channel 2 4 fixed ranges 2'000 pc - 20'000 pc Adjustable limit value with switching output Peak value and test function Serial RS 232 interface Electrical Data Voltage supply VDC Capacity draw < 1,5 W (1) Measuring range channel 1 ±100' '000 pc Measuring range channel 2 ±2' '000 pc Output signal ±10 V Characteristic curve < 1% FS deviation Linearity < 0,02%FS Output offset < ±5 mv Noise voltage < 5 mvpp (0,1 Hz khz) (2) Output impedance 10 Ω Reset operate offset < ± 10 mv Drift < 0,03 pc/s at 23 C (3) Frequency range (-3 db) khz (4) Control input ± 5 V...± 45 V, galv. separated Switching output max. 45 V, max. 100 ma galv. separated (1) < 55 ma at 24 V Order Code DACU BS Included Mounting screws 2 pcs. M4 x 16 Dimensions (mm) (2) < 20 mvpp in the 2000 pc range (3) DACU at least 30 min attached to operational voltage 2'000 pc...100'000 pc; > 2 500'000 pc All specifications at ambient temperature (23 C ±2 C) Mechanical Data Control connection Sensor connection Enclosure material 25 pin D-Sub BNC male Aluminum die cast Environmental Conditions Operating temp. range C Storage temperature C Protection class IP 40 EMC EN immunity EN emission 9.6
113 DACU 820 Electrical Connections D-Sub 25 Pin Function 1 Signal out CH1 2 Peak out 3 Level 1 (In or Out) 4 Level 0 (In or Out) 5 Range B1 (CH2) 6 Range B0 (CH2) 7 Range A1 (CH1) 8 Range A0 (CH1) 9 Supply GND 10 +Supply 11 Code 2 12 Code 0 13 Code Supply + 14 Signal GND 15 Alarm 1 (CH1) 16 Alarm 0 (CH1) 17 RX 18 TX 19 Com Logic Input 20 Operate 21 80% Test 22 Supply GND 23 Signal out CH2 24 Code 1 25 Com Logic Output (Alarm) Measuring Range Selection Range CH1 Measuring Range A1 A0 pc/10v ' ' ' ' '000 Range CH2 B1 B ' ' ' '000 Accessories Connecting cable with open end 50 L Control Elements Length (L) Order code 5 m DZCS 05/DACU 8 9 Range L0 L1 Adjustment of variable range Adjustment of value 1. The limit switch voltage can be set with the potentiometer and has to be measured at pin 4. Alternatively a voltage can be supplied as well. Adjustment limit value 2. ditto, pin 3 only 9.7
114 9.8
115 Supplementary Information 10
116 Supplementary Information Overview of applications for STRAIN-MATE TM and other surface strain sensors Strain ring measures indirectly (shunt measurement) Axial Load in Cylinder Calibrated measurement with strain ring type DSRC. The applied force can be directly calculated by the following formula: F = A x E x ε A = Cross section [mm 2 ] E = E-Modulus [N/mm 2 ] ε = Strain l/l The entire force passes through the cylinder and is measured with two pressed-on strain gages. The more accurate the Young's modulus is known the more precise the force can be measured. Elastic modulus E Steel 210'000 N/mm 2 Titan 105'000 N/mm 2 Aluminum 70'500 N/mm 2 Copper 120'000 N/mm 2 DSRC (Option TO) Torsion Torsion measurement is easy with the strain ring type DSRC/Option TO. Strain rings with option TO can be connected to standard sensopress amplifiers. For rotating torque measurements the strain ring may be connected to a commercially available telemetry system. Bending on a Cylinder The strain ring type DSRC used in a 1/2-bridge arrangement directly measures the axial load compensated bending strain. Bending on Beams or Cross Heads Bending measurements on beams with strain link type DSRT
117 Supplementary Information Force Measurement Load cells measure the force directly. The advantage is that the force can be directly recorded in kn. Alternatively, the indirect (or shunt) force measurement with strain sensors offers the advantage that there is no need to install a load cell into the load flow. In addition the strain sensors cannot be overloaded. On the other hand, it is necessary to calibrate the measuring chain. The indirect measurement always guarantees excellent repeatability. Force Indirect Force Measurement Indirect force measurement can be done with asymmetrically attached strain sensors. The surface strain can contain a superimposed bending component. For a given set up, this component remains proportional to the force. Process monitoring can be performed with or without calibration. DSRT Application: Strain link DSRT for standard applications Load cell (= direct measurement) Hydraulic Presses The load distribution on a hydraulic frame press is measured with two strain sensors. To determine the magnitude of the force, a pressure sensor may be used to measure the hydraulic pressure in the cylinder. For accurate measurements, the system must be calibrated with a load cell installed in the load flow. The load cell for instance, can be temporarily put in place of the tool. DSRT / DSPN Mechanical Presses On presses with a mechanical clamping mechanism, the force can be measured indirectly on the toggle mechanism or on one of the plates. Using sensors with sufficiently high resolution (DSPN), allows one to measure the clamping force and at the same time detect a potential collision. For instance, a collision can be caused by a part not completely removed. With such a high resolution sensor, it is possible to implement a tool protection system on production machinery
118 10.4
119 Glossary and Explanations 11
120 Terms/Explanations General Force Strain STRAIN-MATE Axial Load Strain l ε = l Strain is defined as the non-dimensional ratio of length change / initial length. Microstrain is often used as strain unit. 1 microstrain [µε] m µm = 10-6 = 1 m m Mechanical strain The mechanical strain results of the strain of the E-modulus of the material respectively of the force per area. s = ε *E (in the flexible span) Material E-modulus (typical) bzw. s = F/(E*A) Steel 210 kn/mm 2 Aluminium 70.5 kn/mm 2 Example: 250 µm/m strain equals to a mechanical strain of 52,2 N/mm 2 respectively (52,5 MPa) on steel. Output range The output voltage is the difference between the output signal at zero load and the output signal at nominal load. Nominal characteristic value Specified output signal at nominal load (nom. output voltage). Characteristic value Actual (measured) output range. Measuring range Load range in which the specified errors are not exceeded. Hysteresis Hysteresis signifies the hysteresis error F h. S max is the largest difference between the increasing and decreasing calibration curve up to the nominal load. Hysteresis is expressed in % of full scale. F h = S max F N Output signal ΔS max Output signal at nominal load Measuring range L N (Nominal load)
121 Terms/Explanations General Force Strain STRAIN-MATE Axial Load Characteristic curve deviation The characteristic curve deviation signifies the maximum deviation of the calibration curve to the specified straight line. The specified straight line passes through the origin. The end point results from the origin + nominal output voltage. The characteristic curve deviation contains hysteresis, linearity error, repeatability and deviation of real to nominal output voltage. F Com = S max FS Output signal ΔS max Full scale Output signal at nominal load Measuring range L N (Nominal load) Linearity Linearity error F L is the largest difference S max between the increasing calibration curve and the straight line through the origin with slope C L. C L is selected such that S max is minimized. The linearity is expressed in % of full scale. S max F L = CL L N ΔS max Output signal Measuring range L N (Nominal load)
122 Terms/Explanations General Force Strain STRAIN-MATE Axial Load Micro strain [µε] See strain. Zero, bridge balance Generally all S/G bridges exhibit an initial offset which can be tared by different means. After the installation the offset of STRAIN MATE TM sensors may be quiet large due to the press-on technique. Baumer amplifiers and display instruments are equipped with a reset circuit which allows fast and convenient zeroing over a large range. For static applications, amplifiers with zero balance potentiometers or digital taring are used. Repeatability The difference in reference to the characteristic value between the max. and the min. display value of equal measuring points in case of repeatation of identical load cycles. Test OUT R C + + TEST OUT R C - - SIGNAL OUT RESET The non-tared signal is available at the output Test OUT. To prevent saturation of subsequent stages, Test OUT should ideally read between -2 V and +2 V when the sensor is installed and no load is applied. During operation this value may then be between -5 V and +5 V. The Test OUT output can furthermore be used to check the measuring chain. In case of an open bridge circut, Test OUT goes into saturation. TC of zero signal Output signal T +1 K T FS The maximum temperature coefficient (TC) of the zero signal is the largest variation of the zero signal which occurs during a change in temperature by 1 Kelvin. It is expressed in percent of full-scale per Kelvin. Measuring range L N (Nominal load) TC of output range Output signal T +1 K T FS The largest temperature coefficient (TC) of output range is the largest variation in output range which occurs during a change in temperature by 1 Kelvin. It is expressed in percent of FS *) per Kelvin. Measuring range L N (Nominal load) *) FS = Fullscale of output range
123 Terms/Explanations Strain Gages Force Strain STRAIN-MATE Axial Load Strain gage (S/G) Strain Gage. The S/G changes the electrical resistance proportionally to the applied strain. Gage factor The sensitivity of a S/G is expressed by the ratio of the relative resistance change to the strain: k = R R x 1 ε R Resistance of S/G R Resistance change due to strain ε Strain of S/G Transverse sensitivity Ideally S/G should only react with a resistance change as expressed by the gage factor when strain is applied in the «active» direction of the gage. A resistance change is also observed when strain is exerted transverse to its «active» direction. This is known as transverse sensitivity and is expressed in percent of the gage factor. Temperature compensation When the temperature of the measurement location changes, an output signal is produced. This is due to the change in specific resistance and the thermal expansion of the object. This signal which is known as the temperature output of the measurement point is independent of the mechanical load applied to the object to be measured. The temperature output of a strain gage is controlled through the material properties such that the temperature effects are largely compensated
124
125 Worldwide presence. We strive to be close to our customers all around the world. We listen to them, and then after understanding their needs, we provide the best solution. Worldwide customer service for us starts with on-the-spot personal discussions and qualifi ed consultation. Our application engineers speak your language and strive from the start, through an interactive problem analysis, to offer comprehensive and user-compatible solutions. The worldwide Baumer sales organizations guarantee a high level of readiness to deliver. Africa Algeria Cameroon Côte d Ivoire Egypt Morocco Reunion South Africa For more information about our worldwide locations go to: America Brazil Canada Colombia Mexico United States Venezuela Asia Bahrain China India Indonesia Israel Japan Kuwait Malaysia Oman Philippines Qatar Saudi Arabia Singapore South Korea Taiwan Thailand UAE Europe Austria Belgium Bulgaria Croatia Czech Republic Denmark Finland France Germany Greece Hungary Italy Malta Martinique Netherlands Norway Poland Portugal Romania Russia Serbia Slovakia Slovenia Spain Sweden Switzerland Turkey United Kingdom Oceania Australia New Zealand
Force and strain sensors. Measure. Test. Control.
Force and strain sensors. Measure. Test. Control. Force and strain sensors by Baumer combine tried and tested technology and sophisticated innovations. 1 Contents. Introduction 1 Force and strain sensors
More informationForce and strain sensors. Measure. Test. Control. Edition 2016
Force and strain sensors. Measure. Test. Control. Edition 2016 Force and strain sensors by Baumer combine tried and tested technology and sophisticated innovations. 1 Contents. Introduction 1 Product key
More informationK3D60a ±100N. Description. The K3D60a three-axis sensor is suitable for measuring force on three mutually perpendicular axes.
K3D60a ±100N Description The K3D60a three-axis sensor is suitable for measuring force on three mutually perpendicular axes. The new 3-axis sensor K3D60a is a further development of the series K3D60 and
More informationLoad Cells LOAD CELLS
Load Cells Honeywell manufactures a wide range of tension, compression, and universal measurement load cells. Our load cells are industrially rugged and feature enhanced reliability due to stainless steel
More informationModel 41E. Precision Low Profile Load Cell DESCRIPTION FEATURES
Precision Low Profile Load Cell DESCRIPTION Model 41E is a low profile pancake type load cells. These bonded foil, strain gage load cells are engineered to measure loads from 20 N to 200 kn. The tension/
More informationOperating Manual Series Load Pins
Operating Manual 5301 Series Load Pins Safety note Use for intended purpose The force transducers in model series F5301 are intended for the measurement of static and dynamic tensile or compressive force.
More informationLoad Cell Accessories and Services
Load Cell Accessories and Services Highlights Strain gage signal conditioners Cable assemblies Mounting accessories Calibration services PCB Piezotronics, Inc. Toll-Free in USA 888-684-0004 716-684-0001
More informationXPC10 High temperature miniature pressure sensor
Absolute, sealed and gauge ranges 10 to 500 bar [150 to 7 500 psi] High temp. operation from -40 up to 220 ºC [-40 to 428 F] Stainless steel construction Amplified output available For static and dynamic
More informationTorque Sensor Accessories and Services
------------------- Torque Sensor Accessories and Services Highlights Strain gage signal conditioners Cable assemblies Speed sensors Shunt calibration modules and thermocouples Calibration services PCB
More informationCSG110 Strain Gauge Universal Amplifier
Quick Start Guide CSG110 Strain Gauge Universal Amplifier Sensor Solutions Source Load Torque Pressure Multi-Axis Calibration Instruments Software www.futek.com Getting Help TECHNICAL SUPPORT For more
More informationTorque Measuring Flange
Force Torque Measuring Flange Digital Telemetry Based, Short-Design, Robust, High Accuracy Type 025DF... Type 025DF... torque measuring flanges operate on the strain gage principle. The integral, digital
More informationTorque Sensor Series 3000 and Series 4000
Properties Sensorshaft with integrated torque and angle measurement Non-contact measurement system, high robustness Plug & Play solution, no additional electronics required Performance Measurement range
More informationModel 3A Series 3-Axis Load Cell
Model 3A Series 3-Axis Load Cell 3-Axis Fx Fy Fz; Independent Bridges 20N to 500kN Force Range Compact Size Low Crosstalk Temperature Compensated Accessories BSC4A 4-Channel Analog Amplifier BSC4D 4-Channel
More informationTechnical data Model F1301 F13C1 ATEX/IECEX 2) F13C1 (Option) Nominal load F nom 10 / 20 / 30 / 50 / 100 / 200 kn 10 / 20 / 30 / 50 / 100 / 200 kn 10
Compression force transducer with Thin-film sensor Accuracy: 1 % Output signal: 4...20 ma; 2-wire, 0...10 VDC; 3-wire Optional Optional ATEX/IECEX II 2G Ex ib IIC T4/T3 for SIL3-Applications with 2-channel
More informationConnection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition
Converter Connection 1-channel EEx ia IIC for 4-wire and 6-wire bridges Analogue output 0/4 ma... 20 ma or 4mA...-12mA Full bridge load cells and strain gauges circuit for resistance bridges up to 17 Ω
More informationModel 3A Series 3-Axis Load Cell
Model 3A Series 3-Axis Load Cell 3-Axis Fx Fy Fz; Independent Bridges 20N to 500kN Force Range Compact Size Low Crosstalk Temperature Compensated Accessories Model 3A60A BSC4A 4-Channel Analog Amplifier
More informationIncremental encoders With blind or through hollow shaft pulses per revolution programmable
Features Size mm Precise optical sensing Output signal level programmable (TTL or HTL) Blind or through hollow shaft, ø8 15 mm Connection axial, radial or tangential Pulses per revolution 1...65536, programmable
More informationU10M. Force Transducer. Special features. Data sheet. Mounting dimensions of the connection variants in mm [inch]
U10M Force Transducer Special features - Precise and robust tensile/compressive force transducer for static and dynamic measurement tasks - High lateral force and bending moment stability, the effect of
More informationModel LBS Miniature Compression Load Button
Model LBS Miniature Compression Load Button Why the Interface model LBS Miniature Compression Load Button is the best in class: Temperature compensated Integral load button Small diameter From." height
More informationXXXX e. X d.. X X X a
The Heavy uty incremental encoder type 0H boasts a high degree of ruggedness in a very compact design. Its special construction makes it perfect for all applications in very harsh environments. / RoHS
More informationModel UG. Ultra Precision Universal Canister Load Cell DESCRIPTION FEATURES
Ultra Precision Universal Canister Load Cell DESCRIPTION Model UG Ultra Precision Universal load cell achieves scale quality and performance standards.the Model UG achieves ±0.03 % non-linearity with very
More informationCatalog of CLA force and torque sensors
Catalog of CLA force and torque sensors SC-002 LC-01 LC-10 TSF-000 TSF-05 TSF-1 TSF-100 Micro-force sensor Force sensor Micro-torque sensor Torque sensor Phone +41 32 421 44 90, Fax +41 32 421 44 91, ventes@cla.ch,
More informationSeries 7000 Torque Sensor for PTO-shafts
Properties PTO (Power Take-Off) shaft with integrated torque and angle measurement Non-contact measurement system, high robustness Special for PTO shafts 1 ¾ und 1 3/8 Plug & Play solution, no additional
More informationModel Tension/Compression Pancake Load Cell DESCRIPTION FEATURES
Model 3173 Tension/Compression Pancake Load Cell DESCRIPTION The Model 3173 covers the lower capacity ranges of 200 pounds force to 3000 pounds force, while exhibiting the high performance characteristics
More informationn Measuring range ,02 N m to N m n Clockwise and counter-clockwise torque n Low linearity deviation of ± 0.05 % F.S.
Precision Torque Sensor Non-contact transmission for rotating applications Optional measurement of angle and speed Model 8661 Code: Delivery: Warranty: 2-3 weeks 24 months Application The 8661 precision
More informationSRS SEALED ROTARY SENSORS
SRS SEALED ROTARY SENSORS Innovation In Motion INNOVATION IN MOTION Penny+Giles SRS280 sealed rotary sensors and SRS880 submersible rotary sensors have been specially developed to provide maximum performance
More informationU15. Force transducer. Special features. Data sheet. Installed dimensions of connection variants
U15 Force transducer Special features - Tensile/compressive force transducer - Nominal (rated) forces 2.5 kn to 2.5 MN - lass 0.5 to ISO 376 in force measurement range between 10% and 100% of the nominal
More informationTechnical data. Your advantages
Technical data Nominal torque: 50 Nm to 2.000 Nm, bidirectional Rotational speed: 10.000 rpm Accuracy: ±0,2 % Temperature range: -40 C to +85 C Protection class: IP50, IP65 Output signals: 0-10 V/4-20
More informationCable transducer Analog output / redundant Measuring length absolute up to 5 m
Features Magnetic sensing method Resolution: 12 bit Interface analog 0...10 V / 0.. V /...20 ma Measuring length up to m Removable stickers for water outlet Teach inputs Extremely light thanks to housing
More informationR30D RVDTs DC-Operated Rotary Variable Differential Transformers
R30D RVDTs DC-Operated Rotary Variable Differential Transformers RVDTs incorporate a proprietary noncontact design that dramatically improves long term reliability when compared to other traditional rotary
More informationn Measurable displacements between n Linearity: max. ± 0.05 % n Housing diameter 12.9 mm n Service life: 10 8 movements
Potentiometric Displacement Sensor Miniature design Model 8709 Code: Delivery: Warranty: 8709 EN ex stock 24 months Application Potentiometric displacement sensors are used for direct, precise measurement
More informationTorque Sensor. Torque. with Dual-Range-Option. Type 4503A...
Torque Torque Sensor with Dual-Range-Option Type 4503A... Type 4503A... torque sensors with built-in speed sensor operate on the strain gage principle. An integral, digital measurement conditioning system
More informationK3R110 ±50N; ±100N, ±200N; ±500N, ±1000N, ±2000N; ±5000N
K3R110 ±50N; ±100N, ±200N; Description The force sensor K3R110 is suitable for inspection tasks in quality assurance as well as in materials testing because of its compact design. This precision force
More informationTorque Sensor. Torque. Dual-Range Sensor with Brushless Transmission. Type 4503A...
Torque Torque Sensor Dual-Range Sensor with Brushless Transmission Type 4503A... Type 4503A... torque sensors with built-in speed sensor operate on the strain gage principle. An integral, digital measurement
More informationIncremental encoders With blind or through hollow shaft pulses per revolution programmable
Features Size ø58 mm Precise optical sensing Output signal level programmable (TTL or HTL) Blind or through hollow shaft, ø8 15 mm Connection axial, radial or tangential Pulses per revolution 1...65536,
More informationTECHNICAL MANUAL. SERIES AP5202 DC Strain Gage In-Line Amplifier ISO 9001/AS9100
TECHNICAL MANUAL SERIES AP5202 DC Strain Gage In-Line Amplifier ISO 9001/AS9100 Due to the nature of technology, changes are inevitable. For latest technical specifications, see our website. Copyright
More informationModel RGH. Rod End In-line Compression/Tension Load Cell DESCRIPTION FEATURES
Rod End In-line Compression/Tension Load Cell DESCRIPTION The Model RGH In-Line load cells are high quality, stainless steel, rugged load cells capable of withstanding significant off-axis loads, making
More informationModels Tension/Compression Pancake Load Cell Model 3174 with tension base DESCRIPTION FEATURES
Models 3174-3176 Model 3174 Model 3174 with tension base DESCRIPTION Models 3174, 3175, and 3176 are fatigue-resistant, low-profile tension and compression load cells that are well suited to materials
More informationph or ORP Transmitter
ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes
More informationSETUP SUNSTAR 传感与控制 Model 3173 PERFORMANCE SPECIFICATIONS Load range 1 Accuracy 0.07 % Non-linearity Hysteresis Repeatabilit
Model 3173 DESCRIPTION The Model 3173 covers the lower capacity ranges of 200 pounds force to 3000 pounds force, while exhibiting the high performance characteristics of stiffness and accuracy. These load
More informationNOVOHALL Rotary Sensor touchless transmissive. Series RFX-6900
NOVOHALL Rotary Sensor touchless transmissive Series RFX-6900 Special features Very robust design to extreme environmental conditions Touchless hall technology Electrical range up to 360, in single and
More informationED701 General Industry Pressure Transmitter
ED701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationeddyncdt 3010 Non-Contact Displacement Measuring Systems
Eddy current sensors for displacement, distance and position Eddy current and inductive measurement system and sensors with micrometer resolution for linear measurement and displacement, distance and position
More informationTelemetrie-Messtechnik Schnorrenberg
Telemetrie-Messtechnik Schnorrenberg CT16-Wheel User manual TMS Telemetrie-Messtechnik Schnorrenberg Dipl.-Ing. Werner Schnorrenberg Habichtweg 30, D-51429 Bergisch Gladbach, Tel: 02204-9815-52, Fax: 02204-9815-53,
More informationTension/compression force transducer. With thin film technology up to 100 kn. Models F2301, F23C1, F23S1. Force. Applications.
Force Tension/compression force transducer With thin film technology up to 100 kn Models F2301, F23C1, F23S1 WIKA data sheet FO 51.17 Applications Crane systems and hoists Industrial weighing technology
More informationNOVOHALL Rotary Sensor non-contacting. Series RSX-7900
NOVOHALL Rotary Sensor non-contacting Series RSX-7900 Special features very robust design to extreme environmental conditions high shaft load 300 N non-contacting, magnetic measuring angles up to 360 in
More informationTORQUE. Quick-ship program - torque
Torque Honeywell Sensing and Control s torque sensors feature both reaction (non-rotating) and rotary torque sensors that utilize bonded strain gage technology. The rotary torque capability offers both
More informationModel 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R
O P E R AT I O N M A N U A L Model 4800 L O A D C E L L S U M M I N G T R A N S M I T T E R CALEX Manufacturing Company, Inc. Concord, California 94520 Ph: 925/687-4411 800/542-3355 Fax: 925/687-3333 http://www.calex.com
More informationWater Cooled Absolute Pressure Sensor
Pressure Water Cooled Absolute Pressure Sensor High Temperature Gas Pressure Measurement The water cooled piezoresistive absolute pressure sensor is a small, rugged sensor suitable for exposure to hot
More informationXXXX e. X d.. X X X a
The Heavy Duty incremental encoder type 0H boasts a high degree of ruggedness in a very compact design. Its special construction makes it perfect for all applications in very harsh environments. / RoHS
More informationLOAD MEASURING PINS LE-LU SERIES FEATURES DESCRIPTION APPLICATIONS
LE-LU SERIES LOAD MEASURING PINS Magtrol offers a wide range of Load-Force-Weight Transducers with optional integrated electronics or Load Monitoring Units (LMU) with B.I.T.E. functions creating an ideal
More informationTension/compression force transducer. With thin film technology up to 100 kn. Models F2301, F23C1, F23S1. Force. Applications.
Force Tension/compression force transducer With thin film technology up to 100 kn Models F2301, F23C1, F23S1 tecsis data sheet FO 51.17 Applications Crane systems and hoists Industrial weighing technology
More informationIncremental encoders Blind or through hollow shaft ø12 mm pulses per revolution
Blind or through hollow shaft ø mm...5 pulses per revolution Features Encoder with blind or through hollow shaft ø mm Optical sensing method Max. 5 pulses per revolution Small profile depth Versatile mounting
More informationTQ 402 & TQ 412 / EA 402 / Proximity System : TQ 402 & TQ 412 Proximity Transducers EA 402 Extension Cable IQS 452 Signal Conditioner FEATURES
: TQ 402 & TQ 412 Proximity Transducers EA 402 Extension Cable IQS 452 Signal Conditioner TQ 402 & TQ 412 / EA 402 / IQS 452 FEATURES Non-contacting measurement system based on eddy current principle Certified
More informationRTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC
Technical Information TI 273T/02/en 60021667 RTD Temperature Sensor omnigrad T -TSM 480, TR 480 Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC Application The Omingrad
More informationABSOLUTE ROTARY ENCODER SSI
Main Features - Compact and heavy-duty industrial model - Interface: Synchronous-serial (RS 422) - Housing: 58 mm - Shaft: 6 or 10 mm - Hollow shaft 12 mm - Blind hollow shaft 15 mm - Max. 65,56 steps
More informationSensors for Small Forces
Force Sensors for Small Forces 0,5... 0,5 N to 500... 500 N Type 9203, 9205, 9207, 9215A, 9217A These slim sensors are designed for dynamic and quasistatic tensile and compression forces. Depending on
More informationSensor Datasheet Collection
ISO 9001 REGISTERED Specials are Our Standard Sensor Datasheet Collection CONTENTS HR-DRO: HIGH RESOLUTION DIGITAL READOUT 3 THE RELS FAMILY: ROD-END LOAD SENSORS 4-15 S-RELS SERIES: STANDARD ROD-END LOAD
More informationMICROMACHINED SILICON MODULAR PRESSURE SENSOR
MICROMACHINED SILICON MODULAR PRESSURE SENSOR Configurable High Accuracy High Temperature Performance For Industrial, Test and Measurement, and Aerospace Applications Low Pressure from 10 in-h 2 O to 2.5
More informationPressure Transmitter SIL
Pressure Transmitter SI Characteristics - TRANSDUCER - Pressure: Range: Output: Accuracy: Temperature of medium: Material enclosure: Pressure connection: Electrical connection: Protection: relative / absolute
More informationPressure measurement PBMR Fully welded pressure transmitter for railway applications
Fully welded pressure transmitter for railway Product highlights Ecellent accuracy and long term stability up to % FS Active temperature compensation over the entire operating temperature range Sensor
More informationNOVOTURN Multiturn Sensor non-contacting. Series RSM-2800
NOVOTURN Multiturn Sensor non-contacting Series RSM-2800 Special features Non-contacting, magnetic Long life Electrical range 720 up to 5760 in 360 -steps available (2 to 16 turns) True-Power-On System:
More informationStrain Gauge Measuring Amplifier BA 662
Strain Gauge Measuring Amplifier BA 662 Original of the Manual Table of Contents 1. Safety precautions... 2 1.1. Field of application... 2 1.2. Installation... 2 1.3. Maintenance... 2 2. Function... 2
More informationTel: (949) Fax: (949) IAA100 Product Manual
IAA100 Product Manual Table of Contents Default Settings... 3 Connections... 3 Standard Span & Zero Adjustment... 4 Shunt Readings... 5 Digitally Controlled Remote Shunt... 5 Switch Configurations... 6
More informationMaterial: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:
Shaft Encoder - Ø 50 mm Shaft: Ø 6 mm to Ø 12 mm Resolution up to 12.500 ppr IP 65 (IP 67 option) Formerly named 2R or 2R-3L Automation / Electrical Specifications Code: Resolution: Supply Voltage: Voltage:
More informationOnline data sheet AFS60B-S4PA AFS/AFM60 SSI ABSOLUTE ENCODERS
Online data sheet FS60-S4P032768 FS/FM60 SSI FS60-S4P032768 FS/FM60 SSI C D E F Ordering information Type Part no. FS60-S4P032768 1037483 Other models and accessories www.sick.com/fs_fm60_ssi Illustration
More informationModel RH. Rod End In-line Tension Load Cell DESCRIPTION FEATURES
Rod End In-line Tension Load Cell DESCRIPTION Model RH, with male and female threads, is a high output rod end load cell designed to be mounted inline to the load axis to measure tension. The outputs for
More informationAero Support Ltd, 70 Weydon Hill Road, Farnham, Surrey, GU9 8NY, U.K.
4-170 Piezoelectric Accelerometer The CEC 4-170 accelerometer is a self-generating, piezoelectric accelerometer designed for medium temperature vibration measurement applications. This instrument provides
More informationDx: Digital Multi-Channel Telemetry System
Instrumented shaft with signal conditioning and transmitter unit (SCT) and inductive power supply Receiver, Control and Interface Unit (RCI) For measurements with rotating objects, a telemetry system for
More informationDP2000 ORDERING GUIDE To Order MODEL NO.
1 8 DIN VERSATILE PROCESS MONITORS CONFIGURABLE DP2000-S, 1 8 DIN meter, shown smaller than actual size. DP2000 Series Complete with Input Board RoHS 2 Compliant DP2000-J1, with TJ36-ICSS-116G-12, transition
More informationTechnical data. General specifications. Linearity error ± 0.1 Electrical specifications Operating voltage U B
Model Number SYNCHRON SERIELLES INTERFACE Features Very small housing Up to 32 Bit multiturn SSI interface Free of wear magnetic sampling High resolution and accuracy Description The ENA36IL series are
More informationTQ 401 / EA 401 / IQS 451. Proximity System : TQ 401 Proximity Transducer EA 401 Extension Cable IQS 451 Signal Conditioner FEATURES
Proximity System : TQ 401 Proximity Transducer EA 401 Extension Cable IQS 451 Signal Conditioner FEATURES Non-contacting measurement system based on eddy current principle Certified for use in potentially
More informationTPFADA FLUSH DIAPHRAGM PRESSURE TRANSMITTER WITH DIGITAL AUTOZERO & SPAN
TECHNICAL DATA TPFADA FLUSH DIAPHRAGM PRESSURE TRANSMITTER WITH DIGITAL AUTOZERO & SPAN Main features Ranges: from 0...10 to 0...1000 bar Output signal 4...0mA -wires / 0.1...5.1Vdc / 0.1...10.1Vdc / 0...5Vdc
More informationCTP16-Rotate. KMT - Kraus Messtechnik GmbH
KMT - Kraus Messtechnik GmbH Gewerbering 9, D-83624 Otterfing, Germany, 08024-48737, Fax. 08024-5532 Home Page http://www.kmt-telemetry.com, Email: info@kmt-telemetry.com CTP16-Rotate 16 channel telemetry
More informationICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A...
Electronics & Software ICAM Type 5073A... Industrial Charge Amplifier for Applications in Manufacturing The ICAM charge amplifier (Industrial Charge Amplifier Manufacturing) converts the piezoelectric
More informationModel 140 Inline Amplifier
Model 140 Inline Amplifier Low Noise Inline Amplifier Small Rugged Package Includes Auto-Zero Function The Model 140 is a remote in-line DC amplifier designed to be used with bridgetype mv output transducers.
More informationProtection class IP67/IP69K Magnetic measurement principle
POSITILT PTAS2 Magnetic inclination sensor with analog output Magnetic inclination sensor in a 36 mm housing Protection class IP67/IP69K Magnetic measurement principle Outputs: Voltage 0.5... 4.5 V; 0.5...
More informationInductive Standard Displacement Transducers
WA Inductive Standard Displacement Transducers Special features - Available as displacement probe or with detachable plunger - Good thermal stability in the event of temperature gradients - Space saving,
More informationTemposonics. Magnetostrictive Linear Position Sensors. ER Analog Data Sheet
Temposonics Magnetostrictive Linear Position Sensors ER Analog Compact sensor model Operating temperature up to +75 C (+167 F) Ideal for flexible mounting MEASURING TECHNOLOGY The absolute, linear position
More informationup to 200 C, 4007B... Technical Data 4007B, General Measuring range bar Overload bar Power supply ma* 1 Output signal (FS
Pressure SUNSTAR 传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 E-MAIL: High Temperature Pressure Sensor 5 and 20 bar Version for Temperatures up to 200 C 4007B... Rugged pressure sensor for the measurement
More informationHigh Performance Current Transducer IT 200-S ULTRASTAB = A. ε L
High Performance Current Transducer IT 200-S ULTRASTAB For the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation between the primary circuit and the secondary circuit. I PM
More informationT22. Torque transducer. Special features. Data sheet
T22 Torque transducer Special features - Nominal (rated) torques 0.5 Nm, 1 Nm, 2 Nm, 5 Nm, Nm, Nm, 50 Nm, 0 Nm, 0 Nm, 500 Nm and 1 knm - Nominal (rated) rotational speed up to 000 rpm (depending on measuring
More informationELPF Load Cell DESCRIPTION
Compact Tension/Compression Design 10 500 lbf High Level and mv Output High Stability Industry Standard Packing Resists Off Axis Load Components Full NIST Traceable 11 Point Calibration Shielded Teflon
More informationWater Cooled Absolute Pressure Sensor
Pressure Water Cooled Absolute Pressure Sensor High Temperature Gas Pressure Measurement Patent pending The water cooled piezoresistive absolute pressure sensor Type 4049A is a small, rugged sensor suitable
More informationU5300 Industrial Pressure Transducer
Superior Accuracy and Total Error Band Instrument Grade CE Compliant Compact Variety of Pressure Ports and Electrical Configurations Optional Stainless Steel Snubber Weatherproof Gage, Sealed, Absolute,
More informationRotary Position Technology Incremental Encoders
-40 to 80 C Temperature Shock/vibration resistant Short-circuit protected Reverse polarity protection High rotational speed Rugged Balanced, stainless-steel clamping rings, special bearing-shaft connection
More informationPhone: Fax: Web: -
ue to their sturdy bearing construction in Safety-ock esign, the Sendix 5000 and 500 offer high resistance against vibration and installation errors. The rugged housing, high protection level of up to
More informationTechnical data. General specifications V DC Power consumption P 0. 1 W Time delay before availability t v
Model Number SYNCHRON SERIELLES INTERFACE Features Very small housing Up to 32 Bit multiturn SSI interface Free of wear magnetic sampling High resolution and accuracy Description The ENA36IL series are
More informationVariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.
ProLine Interface Technology Transducers for High Voltage / Shunt Applications Compact high voltage transducers with VariPower broad-range power supply and genuine calibrated range selection. The Task
More informationThe World of Motion Control
PWB-Ruhlatec Industrieprodukte GmbH Siegburger Str. 39a 53757 Sankt Augustin Germany www.pwb-technologies.com info@pwb-technologies.com AE30 medium temperature range LD 1 of 9 Rev. 3.0 / 06.07.2007 Description
More informationIXARC Incremental Encoder UCD-IPT M100-PRD. Interface Programmable Incremental. Configuration Tool UBIFAST Configuration Tool (Version 1.6.
IXARC Incremental Encoder UCD-IPT00-08192-M100-PRD Interface Interface Programmable Incremental Programming Functions PPR (1-16384), Output, Counting Direction Configuration Tool UBIFAST Configuration
More informationP125 High pressure sensor
Ranges from 2000 to 7000 bar Stainless steel Robust for Fatigue testing High level output in option For static and dynamic applications Linearity up to ±0.3% F.S. DESCRIPTION The P125 is a high pressure
More informationRotary Measurement Technology Incremental Encoders
-20 to 60 C Temperature Shock/vibration resistant Short-circuit protection Reverse polarity protection High rotational speed Rugged Balanced, stainless-steel clamping rings, special bearing-shaft connection
More informationLoad Cells Shear beam load cells SIWAREX WL230 SB-S SA
oad cell Overview Combined error comb Repeatability v ±0.0% C n ±0.0% C n The shear beam load cell is particularly suitable for implementation in container, overhead rail conveyor and platform scales.
More informationData Sheet THE SCA121T DUAL AXIS INCLINOMETER MODULES. Features. Applications
Data Sheet THE SCA121T DUAL AXIS INCLINOMETER MODULES The SCA121T Series contain 3D-MEMS-based dual axis inclinometer modules that provide instrumentation grade performance for leveling applications in
More informationLENORD. +BAUER... automates motion. GEL 2444K PG Configurable rotational speed and position sensor with operating hours counter
GEL 2444K PG Configurable rotational speed and position sensor with operating hours counter LENORD +BAUER... automates motion. Technical information Version 2015-03 General The measuring system comprises
More informationShear beam With thin-film technology from 2 kn Models F3301, F33C1, F33S1
Force Shear beam With thin-film technology from 2 kn Models F3301, F33C1, F33S1 Rated force From 0...2 kn Applications Industrial weighing technology Machine building and plant construction, manufacturing
More informationSW 16mm. SW 15mm. SW 19mm
M B-Coding Automation Technology 7 series Screw locking acc. to DIN EN 6076--0 Degree of protection IP67 Moulded versions Degree of protection IP68 Easy assembly Excellent EMC shielding Versions with shielding
More informationNOVOHALL Rotary Sensor non-contacting. Series RSC2800 analog
NOVOHALL Rotary Sensor non-contacting Series RSC2800 analog The RSC 2800 sensor utilizes a contactless magnetic measurement technology to determine the measured angle. Unlike conventional Hall sensors,
More informationOnline data sheet. DBS60E-TECJD1024 DBS60 Core INCREMENTAL ENCODERS
Online data sheet DS60ETECJD1024 DS60 Core C D E F H I J K L M N O P Q R S T Ordering information Type Part no. DS60ETECJD1024 DS60ETECJD1024 Other models and accessories www.sick.com/ds60_core Illustration
More information