patented MANUFACTURING AND MINOR INVENTIONS

Size: px
Start display at page:

Download "patented MANUFACTURING AND MINOR INVENTIONS"

Transcription

1 patented MMI MNUUING N MINO INVENION PI- K Perimeter warning system Installation Manual EPEME M

2 I PINIPE N EQUIEMEN: he principle of the PI system is based on the ability to generate a single or dual infrared beam that can be segmented around the premises to be protected and provide individually identifiable detection all on a wire U. Up to single or dual beam segments may be used. ypically, each segment comprises of a start unit and a receiver unit ll the units are wired in parallel on a two wire U which means that all positives are connected together and negatives are connected together in whatever form is suitable for that installation (ie. star or loop) second set of beams may be installed in parallel to any one in each segment to provide a dual beam feature, to reduce false alarms, which is wired all on the same two wire U. he two wire U is connected to the PI Keypad he PI Keypad provides both power and control to the x, x, x and x units. HE WO WIE U IE OH POWE N I MU NO E UE O IPY POWE O EVIE OHE HN UNI EONGING O HE PI YEM. he distance between the transmitting and receiving beams depends on the model used. he PI- model has a suggested maximum range of m he PI- model has a maximum range of m NOE: he maximum range is dependant on environmental conditions, alignment accuracy and adequate power supply and correct wiring ll of the units used must be programmed to either eam or eam (or dual beam application) using the jumpers provided on the unit itself. ll x units must be programmed to represent a segment number ( to ) using the jumpers provided on the unit itself In particular applications where the same segment needs to be extended or repeated, a special x and x pair is used. In this case the beam from an x unit is sent to an x unit which in-turn forwards it via a x unit to an x unit. x units automatically repeat the beam they see and need no programming. O x, x, x and x UNI PI E E M PE WN PI KEYP M WN M

3 EXMPE O IEEN ONIGUION ingle individual segments ual individual segments egment extender egment Multiplier M

4 M PE WN M WN ONNEION EXMPE UING HE PIK ME UNI ( EE PI K OMPEE INUION) ystem with combination of INGE, U and MUIPIE EM U U ONNEING OK INGE PI E E INGE INGE INGE MUIPIE/ OWE NOE: s the two U wires carry both power and data they MU NO be used to supply power to devices other than units belonging to a PI system. M

5 M PE WN M WN M PE WN M WN H M INION EXMPE INIVIU E GMEN - UE x and x onnections ig PI E E + - -X+ +IN - EQUENI - EGMEN onnections PI E E Note: connect + or IN+ ogether connect - or IN- ogether M

6 M PE WN M WN M PE WN M PE WN M WN M WN INING U EM IN IEEN ONIGUION OUE EM EGMEN UING WO UNI PI E E OUE EM EGMEN UING N UNI PI E E WIING EWEEN N UNI HO POIE EGMEN WIH OUE EM UING OMINION O - N PI E E WIING EWEEN N UNI HO POIE M

7 M PE WN M WN OMINE INGE N OUE EM ONIGUION PI E E Note: connect + or IN+ ogether connect - or IN- ogether M

8 INING N IGNING HE PI YEM ( INEIGEN ME UNI/ INEE O M PNE) Please follow these steps for a trouble free installation: - Mount the devices using the appropriate brackets and ensure that the mounting is sturdy and secure - ilt and turn the lenses in each unit in the same segment to face each other (fig ) - onnect all the units in parallel as shown in fig, carefully observing the polarity - Program the segment I.. number in each x module using the provided jumpers - ensure that the E ENE jumper is in - onnect the positive and negative wires to the master unit / keypad from any unit as shown in fig. - onnect the external buzzer and power to the master unit / keypad (fig ) he voltage free contact of the light relay on board may be used to activate a power relay which in turn will switch the security lights on. - fter Power is applied check that all x units are flashing - slow rate (hort pulse every second) indicates that they are connected correctly but are not aligned - fast rate indicates that the unit is connected correctly and aligned but not necessarily optimized - Optimize the alignment by moving the lenses from left to right and up and down and find the centre between losing the alignment (fig) - Once all the beams are properly aligned, all the x units should be flashing at a fast rate. - asten the screws that hold the lenses (fig) - If the units are close together it is possible that one x unit will affect more than one x unit. In some cases this could be an advantage but if this effect is not required it is possible to adjust the power output of the x unit from high to medium to low (fig) - earn the segments on the Master unit / PI K (efer to installation instructions) - If necessary, program the sensitivity (detection time) or each segment (efer to installation instructions) NOE: If a receiver unit does not receive any signal from its corresponding transmitter unit for minutes it will enter an auto exclusion mode which is indicated by intermittent flashing ( sec on sec off) his is to prevent constant triggering in case an obstacle falls and breaks the beam permanently. ig (step ) PI- (mt range) ig (step and ) PI- (mt range) ig a (step and ) M

9 H M M PE WN M WN H M H M + M PE WN M WN + - +IN - PI- EGMEN EEION E ENE (IN) EEIVE UNI Jumper for U EM selection: OU = EM IN = EM ig (step ) JUMPE + - EEIVE UNI PI- E ENE Jumper for EM selection: OU = EM IN = EM X ig a (step) EGMEN EEION + - -X+ +IN X+ +IN - ig (step ) + - -X+ +IN X+ +IN - EEIVE UNI E (step) E ENE PI- (step) Jumper for U EM selection: OU = EM E IN = EM insert over pins eam Power selection: H = high (long segment) M= medium (medium segment) = low (short segment) +IN X+ UNI H M ig (step) E Enable Jumper for U EM selection: OU = EM IN = EM (step) EEIVE UNI + - (step) E ENE PI- Jumper for U EM selection: OU = EM IN = EM (step) UNI M H + - ig a (step) E Enable Jumper for U EM selection: OU = EM IN = EM (step) eam power selection: H = high (long segment) M= medium (medium segment) = low (short segment) PI E E + - -X+ (step) eam ounder +IN - O EXEN UZZE (OPION) PI E E + - V upply ig (step ) o eams or units) + - -X+ +IN X+ +IN - ig (step ) M

10 + - he and units are designed to provide you with the possibility to duplicate one beam on the same segment either to further the range or to provide you with a barrier type protection. hi is shown on fig. and fig. he unit connect inparalle with the ands units. onnections between the and units are shown in fig and a ig ig PI- OW UNI ig PI- ig a OW UNI + - -X+ X + - E ENE E ENE NMI UNI M H V eam power selection: H = high (long segment) M= medium (medium segment) = low (short segment) X M H V NMI UNI M H V E ENE eam power selection: H = high M= medium = low M

11 M PE WN M WN he PI Keypad In the PI Keypad the detection time of the segments may be individually programmed to allow for both fast and slow reaction to a breaking of the infrared beam. he PI Keypad may also be programmed to activate an alarm either after a single break or after breaks. When selecting the three breaks you can further choose an alarm activation after the ME beam has been broken three times or after any three breaks within one minute window. ny further breaks within that minute will extend the third break audio signal, extend the time-out by a further minute and resend the alarm. he PI Keypad gives a single audio signal to indicate a single break option (see fig ) he PI Keypad uses different audio signals to indicate the three breaks in multi-break mode(see fig ) continuous interruption of the same beam (in same beam operation) will sound as shown in fig uzzer output gives different sounds for different stages of the breaks. irst break ec rigger alarm ig uzzer output uzzer Operation irst break econd break ec ec ec on ec off rigger alarm ig hree breaks within minute irst break econd break hird break urther breaks ig When armed the unit displays the segments which are armed with running Es and those that are isolated with a steady light. he PI Keypad will only display the segments that were installed. o automatically assess which segments were installed and aligned you can press. he unit will scan and display all the working beams before memorizing the result. his function may be used to test which beam or segment is not aligned properly as the corresponding E will flicker in sympathy with the alignment (E ON = no alignment E O = full alignment) Power may be taken from: - a v power supply ( provided) - an existing larm panel or directrly from the battery via a protecting fuse V power supply + - v. /H EY Generic alarm panel + - use (mp) Or available zones NEGIVE IGGE PI E E M

12 OY EU PI K POGMMING OPION MNUY EINING HE IVE EO (ll sectors are installed) O... UO-ENING HE IVE EO INE OPION (MOE) EGIE NO. ON = ONO UZZE OUPU O = EXEN UZZE OUPU ON = EE EGMEN EVEY HOU ON = HEE EK ON ME EO O = NO EE O = HEE EK ON NY EO ON = UZZE IMEOU = EON O = UZZE IMEOU = EON ON = HE KEY WI IENE UZZE ON = ONG( O ec ) UZZE IMEOU ON = PE ON = PE O = HE KEY WI ONY EE HE IPY O = HO ( ec) UZZE IMEOU O = PE O = PE NOE H OPION I VIE ONY I OPION I EEE (ON) NOE: HE OPION IE EOW MU E POGMME ONY E YOU POGMME HE WO OVE!! EING -EK OPION O EH EGMEN Each segment may be program to activate on breaks rather then one single On = breaks OING EO O HE OU PEE EEION If you are the Installer you can change your own code OE O installer???? Existing code HO I EEP { HNGE NEW OE ( IGI) If you are the User you can change your own code HNGE OE O UE???? Existing code MUIPE ENIE E OWE HO I EEP { NEW OE ( IGI) If you are the User you can change the etection time of each sector EING HE EEION IME? O EH EO { UE OE evice evel NO( to ) Use the table to select the detection time (interruption of beam time before alarm) How to arm individual sectors or preselected levels =. ec = ec =. ec = ec =. ec = ec =. ec = ec M PEE PEN "" M PEE PEN "" M PEE PEN "" M PEE PEN "" How to disarm the system isarming the system M

patented PROGRAMMING THE S.P.I. MASTER UNIT Used as Stand Alone or Interface to Alarm Panel

patented PROGRAMMING THE S.P.I. MASTER UNIT Used as Stand Alone or Interface to Alarm Panel I POGING HE.P.I. E UNI o enter the programming mode press OH buttons until the led is ON elect the required option by entering the corresponding Number fter each selection the 8 led array will flash that

More information

Installation Notes. SCR Single Channel

Installation Notes. SCR Single Channel Installation Notes SCR Single Channel Receiver Part No. 100-187 Receives ARM / Disarm / PANIC / Low Batt channels from Ness Radio Keys or Radio PIRs / Radio Reeds. Supports up to four transmitters. Simple

More information

WSA 8 BOX RELE Installation Manual

WSA 8 BOX RELE Installation Manual WSA 8 BOX RELE Installation Manual Description: The WSA Barrier consists of 2 aluminum bars containing electronics and 2 cases with battery adapters. The receiver and the transmitter are both supplied

More information

COD GB / 1.0 RBAND/UMS - RBAND/CSM

COD GB / 1.0 RBAND/UMS - RBAND/CSM INTRODUCTION DESCRIPTION The RadioBand system is designed of Industrial, Commercial and Domestic door and gate applications where a safety edge is used. The system provides a wireless system replacing

More information

Motor 1- GENERAL DESCRIPTION

Motor 1- GENERAL DESCRIPTION 1- GENERAL DESCRIPTI TELECO AUTOMATI SRL - Via dell Artigianato, 16-31014 Colle Umberto (TV) ITALY TELEPHE: ++39.0438.388511 FAX: ++39.0438.388536 This document is the property of Teleco Automation Srl

More information

Copyright 2014 Winnebago Industries, Inc.

Copyright 2014 Winnebago Industries, Inc. anger of electrical shock, burns or death. lways remove all power sources before attempting any repair, service or diagnostic work. Power can be present from shore power, generator, inverter or battery.

More information

RADIOBAND V3 Programming & Installation Manual

RADIOBAND V3 Programming & Installation Manual RADIOBAND V3 Programming & Installation Manual Radioband V3 User s Manual Introduction The RadioBand system is designed for Automatic Gates, Commercial and Domestic door applications where a safety edge

More information

STX Stair lighting controller.

STX Stair lighting controller. Stair lighting controller STX-1792 STX-1792 controller is used to control stairs lighting dynamically. The backlight is switched on with the subsequent steps, depending on the motion directions: ascending

More information

RADIONICS 5501 / o PERIMETER o INTERIOR o o o o o o o o o INSTANT AC CMD

RADIONICS 5501 / o PERIMETER o INTERIOR o o o o o o o o o INSTANT AC CMD RADIONICS 5501 / 4112 o PERIMETER o INTERIOR o o o o o o o o o INSTANT 1 2 3 4 5 6 AC CMD ALL Instant Delay [ 1 ] [ 2 ] [ 3 ] [ 4 ] [ 5 ] [ 6 ] [ 7 ] [ 8 ] [ 9 ] [ 0 ] [ COMMAND ] [ A ] [ B ] [ ENTER ]

More information

Features : 24V 48V RATED CURRENT 62.5A CURRENT RANGE 125A 0 ~ 125A 0 ~ 62.5A RATED POWER. 3000W RIPPLE & NOISE (max.) Note.

Features : 24V 48V RATED CURRENT 62.5A CURRENT RANGE 125A 0 ~ 125A 0 ~ 62.5A RATED POWER. 3000W RIPPLE & NOISE (max.) Note. P-000CC P - 0 0 0 ss 000W ingle Output Power upply Features : AC input ~ 6AC AC input active surge current limiting Conformal Coating High efficiency up to 90% Built-in active PFC function,pf>0.9 Protections:

More information

INTEGRATED VOICE EVACUATION SYSTEM VM-3000 Series

INTEGRATED VOICE EVACUATION SYSTEM VM-3000 Series OPERATION MANUAL INTEGRATED VOICE EVACUATION SYSTEM VM-3000 Series VOICE ALARM SYSTEM AMPLIFIER VM-3240VA VOICE ALARM SYSTEM AMPLIFIER VM-3360VA VM EXTENSION AMPLIFIER VM-3240E VM EXTENSION AMPLIFIER VM-3360E

More information

3000W Single Output Power Supply

3000W Single Output Power Supply 3000W ingle Output Power upply P-3000 series PECIFICAION MODEL OUPU INPU POECION FUNCION ENIONMEN OHE NOE DC OLAGE AED CUEN CUEN ANGE AED POWE OLAGE ADJ. ANGE LINE EGULAION LOAD EGULAION EUP, IE IME HOLD

More information

Activity 3: Wireless Communication Student Handout. Parts Descriptions. Wireless Communications: Wireless Burglar Alarm

Activity 3: Wireless Communication Student Handout. Parts Descriptions. Wireless Communications: Wireless Burglar Alarm Activity 3: Wireless Communication Student Handout Name: Date: For this activity, you will be modifying your wired communication system to make it wireless. In the end, the transmitter/receiver pair will

More information

1000 SERIES INSTALLATION SUPPLEMENT Rev. 7/1/10

1000 SERIES INSTALLATION SUPPLEMENT Rev. 7/1/10 1000 SERIES INSTALLATION SUPPLEMENT Rev. 7/1/10 Smartscan Incorporated 33083 Eight Mile Road Livonia, MI 48152 Phone: (248) 477-2900 Fax: (248) 477-7453 SMARTSCAN INCORPORATED Livonia, MICHIGAN 1000 The

More information

1000 SERIES INSTALLATION SUPPLEMENT Rev

1000 SERIES INSTALLATION SUPPLEMENT Rev 1000 SERIES INSTALLATION SUPPLEMENT Rev. 1-1-12 Smartscan Incorporated 33083 Eight Mile Road Livonia, MI 48152 Phone: (248) 477-2900 Fax: (248) 477-7453 SMARTSCAN INCORPORATED Livonia, MICHIGAN 1000 The

More information

Photo-electric Amplifier ISG-A123 1-channel automatic amplifier

Photo-electric Amplifier ISG-A123 1-channel automatic amplifier Photo-electric Amplifier -channel automatic amplifier Amplifier with modulated infrared light Range up to 25 m (82 ft) Automatic Level Control (ALC) according to assembly distance and direction Test function

More information

Model APS-2K4S and APS-2K4MS

Model APS-2K4S and APS-2K4MS Model APS-2K4S and APS-2K4MS Transmitter Programming Guide This transmitter makes use of icons (symbols) to identify the reaction your security system/keyless entry/and or remote start system, where applicable,

More information

IMPULSE RADIO TRANSMISSION SYSTEM HL 615 Operating Instruction Version 03/2015

IMPULSE RADIO TRANSMISSION SYSTEM HL 615 Operating Instruction Version 03/2015 IMPULSE RADIO TRANSMISSION SYSTEM HL 615 Operating Instruction Version 03/2015 TAGHeuer Timing Page 1 / 8 1. Generality This new Radio HL615, is the next logical step in impulses transmission by TAG Heuer

More information

TVP2 PERFORMANCE TEST TAG MANUAL

TVP2 PERFORMANCE TEST TAG MANUAL TVP2 PERFORMANCE TEST TAG MANUAL Identec Ltd Mercantile Road Rainton Bridge Industrial Estate Houghton-Le-Spring County Durham England DH4 5PH Tel: +44 (0)191 584 4084 Fax: +44 (0)191 584 9077 www.identec.com

More information

SmartFan Multi SD. Speed Control for DC Fans CONTROL RESOURCES INCORPORATED. The driving force of motor control & electronics cooling.

SmartFan Multi SD. Speed Control for DC Fans CONTROL RESOURCES INCORPORATED. The driving force of motor control & electronics cooling. SmartFan Multi SD Speed Control for DC Fans The driving force of motor control & electronics cooling. DC Controls SmartFan Multi SD is a fan speed control and temperature alarm designed for DC fans and

More information

Making Your Railroad Real Infrared Detector/Signal Driver For Crossing Signals CFD-IF (V3)

Making Your Railroad Real  Infrared Detector/Signal Driver For Crossing Signals CFD-IF (V3) Making Your Railroad Real www.sbsignal.com Infrared Detector/Signal Driver For Crossing Signals CFD-IF (V3) CFD-IF Manual 2010 Table of Contents Description Page CDF-IF Description and Materials needed

More information

Single and Dual Preset Counters Hengstler signo 721 series

Single and Dual Preset Counters Hengstler signo 721 series Instruction Leaflet Issued September 1996 8847 Single and Dual Preset Counters Hengstler signo 721 series Operating instructions RS stock no. No. of presets Supply voltage range Type of output Hengstler

More information

DC electrical circuits

DC electrical circuits D elecicl cicuis hpe 8 lecomoive Foce Poenil Diffeences esisos in pllel nd seies icuis wih pcios Beies nd Geneos uen is poduced y pplying poenil diffeence coss conduco (V/). This poenil diffeence is se

More information

Heritage MedCall. Sentry E-Call Model HM-527 Resident Host Panel

Heritage MedCall. Sentry E-Call Model HM-527 Resident Host Panel Heritage MedCall Sentry E-Call Model HM-527 Resident Host Panel 430-527B 0305 Heritage MedCall, Inc. Issue 1, March 2005 Heritage Medcall Sentry Emergency Call System Model 527 Host Panel Installation

More information

User s Guide. Schooners II. Wireless 900MHz Speaker System. Schooners II 900MHz Wireless Speaker System Model: GDI-AQSHR200 /AQSHR21

User s Guide. Schooners II. Wireless 900MHz Speaker System. Schooners II 900MHz Wireless Speaker System Model: GDI-AQSHR200 /AQSHR21 User s Guide Schooners II Wireless 900MHz Speaker System Schooners II 900MHz Wireless Speaker System Model: GDI-AQSHR200 /AQSHR21 IMPORTANT: Please read your User s Guide before using your system INTRODUCTION

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS K4456V1 8/00 FA260RF Keypad/Transceiver About the FA260RF The FA260RF is a combination unit that contains: A FA260KP Fixed Addressable Keypad A 5800TM Transmitter Module A 5881M

More information

PD140FNT60QMU-02C. Through Beam. Main features. Description

PD140FNT60QMU-02C. Through Beam. Main features. Description Through eam Description The PD140 sensor consists of an emitter, which sends out invisible, infrared light, and a receiver, capable of detecting the light from the emitter. The sensor is encapsulated in

More information

RADIOBAND 3G RB3 T868 RB3 R868 USER'S MANUAL

RADIOBAND 3G RB3 T868 RB3 R868 USER'S MANUAL RADIOBAND 3G RB3 T868 RB3 R868 USER'S MANUAL Index INTRODUCTION... 3 Operating... 3 Receiver RB3 R868... 4 Transmitter RB3 T868... 5 ASSEMBLY AND INSTALLATION... 6 1 Installation of the equipment... 6

More information

USER MANUAL. MetalSpy. EAS Add-On Technology for Foil Bag Protection

USER MANUAL. MetalSpy. EAS Add-On Technology for Foil Bag Protection USER MANUAL MetalSpy EAS Add-On Technology for Foil Bag Protection 21 June 2011 Contents 1.0 SPECIFICATIONS & FEATURES... 3 1.1 System... 3 1.2 MetalSpy Diamond... 4 2.0 PCB CONNECTION... 4 2.1 MetalSpy

More information

This document is the property of Teleco Automation Srl who reserves all reproduction and copying rights

This document is the property of Teleco Automation Srl who reserves all reproduction and copying rights 1- GENERAL DESCRIPTION Electronic for the remote control of tubular motors for roller blinds, rolling shutters, doors with limit switch inside or outside the motor, radio receiver section with transmitter

More information

Series 3000 Model R-107A

Series 3000 Model R-107A Series 3000 Model R-107A DUAL TONE SENDER INSTRUCTION MANUAL Monroe Electronics 100 Housel Ave Lyndonville NY 14098 800-821-6001 585-765-2254 fax 585-765-9330 monroe-electronics.com Printed in USA Copyright

More information

HAWK GLADIATOR MICROWAVE COLLISION PREVENTION SWITCHES

HAWK GLADIATOR MICROWAVE COLLISION PREVENTION SWITCHES HAWK GLADIATOR MICROWAVE COLLISION PREVENTION SWITCHES SET UP PROCEDURE 1 Introduction Hawk Gladiator Microwave Switches can be used to detect & indicate a possible collision and therefore prevent boom

More information

BR2 Lap Beacon Manual

BR2 Lap Beacon Manual MoTeC BR2 Lap Beacon Manual Contents Introduction... 1 Overview... 3 Operation...3 Orientation...5 Range...5 Alignment...5 Verifying Operation...6 Split Beacon Use...6 Configuration - Quick Start... 7

More information

MRW 50, MRW 100, MRW 200. External Protection Barrier. Quick Installation Guide

MRW 50, MRW 100, MRW 200. External Protection Barrier. Quick Installation Guide MRW 50, MRW 100, MRW 200 External Protection Barrier Quick Installation Guide Version 1.1, October 2004 Copyright 2004 GE Interlogix B.V.. All rights reserved. GE Interlogix B.V. grants the right to reprint

More information

ENCODING PHOTOCELLS MF6

ENCODING PHOTOCELLS MF6 ENCODING PHOTOCELLS MF6 Wall-mounted encoding photocells, 180 rotation and range of up to 20 mt. The code for the transmitted signal, which must be set at the time of installation, makes it possible to

More information

GROUP OF COMPANIES. MERLIN STEALTH Electric Fence Energizer INSTALLERS MANUAL

GROUP OF COMPANIES. MERLIN STEALTH Electric Fence Energizer INSTALLERS MANUAL GROUP OF COMPANIES MERLIN STEALTH Electric Fence Energizer INSTALLERS MANUAL Revision 1.5 23 February 2007 : INSTALLERS MANUAL Table of Contents 2 INTRODUCTION.. 3 INSTALLER OPTIONS...... 4-11 ALARM SETTING

More information

G703. Installation instructions. residential gate opener for sliding gates. remote control openers security at your fingertips

G703. Installation instructions. residential gate opener for sliding gates. remote control openers security at your fingertips remote control openers security at your fingertips G703 residential gate opener for sliding gates Installation instructions Toll free helpline Please have your serial number and model name available before

More information

Model 5WTX. Transmitter Programming Guide

Model 5WTX. Transmitter Programming Guide Model 5WTX Transmitter Programming Guide These transmitters makes use of icons (symbols) to identify the reaction your security system/keyless entry/and or remote start system, where applicable, will have

More information

USERS GUIDE MATRIX2 DIGITAL INDUCTIVE LOOP SENSORS

USERS GUIDE MATRIX2 DIGITAL INDUCTIVE LOOP SENSORS We open up New Horizons USERS GUIDE MATRIX2 DIGITAL INDUCTIVE LOOP SENSORS APPLICATION The MATRIX is a Digital Inductive Loop Detector used for the detection of vehicular traffic. The MATRIX is the ideal

More information

PHOTOCELLULE HL 2-33 MANUEL D UTILISATION

PHOTOCELLULE HL 2-33 MANUEL D UTILISATION PHOTOCELLULE HL 2-33 MANUEL D UTILISATION Version 02-2009 R:\Timing\PRODUITS\HL2-33\EN\HL2-33_EN_02-09.doc 12.02.2009 Page 1 / 12 DESCRIPTION The Infra-Red photocell HL 2-32 set is composed of two transmitters

More information

TECHNICAL MANUAL FOR LOOP DETECTORS WITH POWERFAIL MEMORY Article Codes: RDET1CM & RDET2CM

TECHNICAL MANUAL FOR LOOP DETECTORS WITH POWERFAIL MEMORY Article Codes: RDET1CM & RDET2CM TECHNICAL MANUAL FOR LOOP DETECTORS WITH POWERFAIL MEMORY Article Codes: RDET1CM & RDET2CM THIS MANUAL IS INTENDED FOR FOREMEN AND TECHNICAL STAFF IN CHARGE OF THE INSTALLATION, OPERATION AND MAINTENANCE

More information

4-Bit MCU Series 13-DIGIT ALARM WATCH COUNTDOWN TIMER

4-Bit MCU Series 13-DIGIT ALARM WATCH COUNTDOWN TIMER 1. ECRIPTION The L9221is a single-chip application of 4-bit microcontroller fabricated in CO technology, with built-in RO, RA, and 12 I/O pin, buzzer and common, segment driver output. This digital 7-function

More information

Flexible Receiver. Installation Notes. Product Part No (304MHz)

Flexible Receiver. Installation Notes. Product Part No (304MHz) Installation Notes Ness SR PLUS Flexible Receiver Product Part No. 106-179 (304MHz) Receives ARM / Disarm / PANI / / Low Batt channels from Ness Radio Keys or Radio PIRs / Radio Reeds. Supports up to four

More information

RDX Quick Start Guide

RDX Quick Start Guide RDX Quick Start Guide Green-GO RDX Quick Start Guide Product description With the Green-GO Radio Interface you can connect your radio to the Green-GO network through a D-SUB 9 connector. Features Connect

More information

English RACON SERIES II RADIO CONTROL SERVICE MANUAL

English RACON SERIES II RADIO CONTROL SERVICE MANUAL English 22.2.2007 RACON SERIES II RADIO CONTROL SERVICE MANUAL Read the instructions supplied with the product before installation and commissioning. Keep the instructions in a safe place for future reference.

More information

TrainSpeed 4. Four separate train speed indicators. Model Railroad Speedometer Operating Manual

TrainSpeed 4. Four separate train speed indicators. Model Railroad Speedometer Operating Manual TrainSpeed 4 Four separate train speed indicators Model Railroad Speedometer Operating Manual TCS Inc. 215-453-9145 Main Number 215-257-0735 Tech Number www.tcsdcc.com SKU: 1548 TrainSpeed Operating Instructions

More information

Midland 248XL I NSTRUCTION GUI DE

Midland 248XL I NSTRUCTION GUI DE Midland 248XL I NSTRUCTION GUI DE INDEX Introduction...2 Function and location of the controls...3 Installation...7 Power supply...7 Installing an antenna...7 How to use your Midland 248XL...8 Frequency

More information

... Performance Series Owner s Guide. Hidden Fence Systems ...

... Performance Series Owner s Guide. Hidden Fence Systems ... ... Performance Series Owner s Guide Hidden Fence Systems... Thank You for Purchasing the DogWatch Hidden Fence System! You have purchased the most technologically advanced hidden fence system available,

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS K4460V2 3/01 6150RFPL2 Keypad/Transceiver About the 6150RFPL2 The 6150RFPL2 is a combination unit that contains: A 6150PL2 Fixed Addressable Keypad A 5800TM Transmitter Module

More information

V-1109RTHF NINE ZONE PAGE CONTROL

V-1109RTHF NINE ZONE PAGE CONTROL Issue 9 V-1109HF NINE ZONE PGE CONO GENE he V-1109HF, Nine Zone Page Control, is a dial select microprocessor controlled page unit to be used with PBX, Electronic Key or 12 elephone Equipment. hese instructions

More information

CAMTO. Arc detecting relay. system. January Revised August D D1200

CAMTO. Arc detecting relay. system. January Revised August D D1200 NEW ARC DETECTING SYSTEM FROM Based on our experience with arc protection since 1962, has developed a new. The units are built into boxes that all fit on a 35 mm DIN-rail. All front plates are dimensioned

More information

Lock And Arm Alarm, also initiate and terminates *Panic

Lock And Arm Alarm, also initiate and terminates *Panic Model 07SPr Transmitter Programming Guide These transmitters makes use of icons (symbols) to identify the reaction your security system/keyless entry/and or remote start system, where applicable, will

More information

Communication Systems, 5e

Communication Systems, 5e Communiaion Syem, 5e Chape 4: Banpa Digial anmiion A. Bue Calon Paul B. Cilly he MGaw-Hill Companie Chape 4: Banpa Digial anmiion Digial CW moulaion Coheen inay yem Nonoheen inay yem Quaaue-aie an M-ay

More information

Ness MCR Multi-Channel Radio Receiver

Ness MCR Multi-Channel Radio Receiver Installer s MANUAL Ness MCR Multi-Channel Radio Receiver Installation and programming manual Revision 2.1 www.nesscorporation.com National Customer Service Centre Ph: 1300 551 991 customerservice@ness.com.au

More information

Programmable Digital Timer

Programmable Digital Timer Programmable Digital imer Digital 7-egment display upply Voltage range of 110-240 VAC Input ignal ensing range of 85-265 VAC/100-265 VDC & 20-60 VAC/DC Inbuilt library of 33 functions covering majority

More information

HL2-32 PHOTOCELL USER MANUAL

HL2-32 PHOTOCELL USER MANUAL HL2-32 PHOTOCELL USER MANUAL Version 11/2013 DESCRIPTION TAGHeuer Timing 10.12.2015 Page 1 / 12 The Infra-Red photocell HL2-32 set is composed of two transmitters (HL2-32E) and two receivers (HL2-32R).

More information

TrainSpeed1. Single train speed indicator. Model Railroad Speedometer Operating Manual

TrainSpeed1. Single train speed indicator. Model Railroad Speedometer Operating Manual TrainSpeed1 Single train speed indicator Model Railroad Speedometer Operating Manual TCS Inc. 215-453-9145 Main Number 215-257-0735 Tech Number www.tcsdcc.com SKU: 1547 TrainSpeed Operating Instructions

More information

USERS GUIDE MATRIX P/N SINGLE DIGITAL INDUCTIVE LOOP SENSOR

USERS GUIDE MATRIX P/N SINGLE DIGITAL INDUCTIVE LOOP SENSOR USERS GUIDE MATRIX P/N 17500001 SINGLE DIGITAL INDUCTIVE LOOP SENSOR APPLICATIONS The MATRIX Digital Inductive Loop Detector is the ideal solution for parking barrier control, motorized gates and doors,

More information

CM-IWM.11 Insulation monitoring relay

CM-IWM.11 Insulation monitoring relay Data sheet CM-IWM.11 Insulation monitoring relay The insulation monitor CM-IWM.11 provides best and up to date insulation monitoring of modern IT systems in an optimum and state of the art way fulfilling

More information

Pair of PMR446 Two-Way Personal Radios Model: TP391

Pair of PMR446 Two-Way Personal Radios Model: TP391 Pair of PMR446 Two-Way Personal Radios Model: TP391 USER MANUAL MANUALE D USO MANUEL DE L UTILISATEUR BEDIENUNGSANLEITUNG MANUAL DE USUARIO MANUAL DO USUÁRIO HANDLEIDING BRUKSANVISNING P/N:086L004722-016

More information

ADVR-053. Hybrid Universal Analog Digital Voltage Regulator Operation Manual

ADVR-053. Hybrid Universal Analog Digital Voltage Regulator Operation Manual ADV-053 Hybrid Universal Analog Digital Voltage egulator Operation Manual elf Excited 5 Amp Analog / Digital Voltage egulator For shunt and auxiliary windings generators With over-excitation and lost of

More information

PANEL UPDATE. May 1, 1998 Folsom, California

PANEL UPDATE. May 1, 1998 Folsom, California PANEL UPDATE May 1, 1998 Folsom, California NOTE: 236E enhanced programming options (pager as receiver format, temporal code 3, duress, keyswitch arming) ARE NOT SUPPORTED by Commander II V3.0 and must

More information

RMILEC NB18 UHF Remote Control Unit Operating Manual

RMILEC NB18 UHF Remote Control Unit Operating Manual RMILEC 4346 NB18 UHF Remote Control Unit Operating Manual 1Warning When the transmitter works, if the antenna were not connected, the result will be severe. With the high power transmitting mode, the transmitting

More information

BATCHMATE 1500 Batch Control Computer Technical Bulletin

BATCHMATE 1500 Batch Control Computer Technical Bulletin TS-5(C) BATCHMATE 5 Batch Control Computer Technical Bulletin DESCRIPTION The BATCHMATE features an 8 digit.55-in. alphanumeric LED display. The pulse input model will accept up to 2, pulses per second

More information

Introduction...1 Overview...2. Beacon Transmitter...7. Beacon Receiver Trouble Shooting...15

Introduction...1 Overview...2. Beacon Transmitter...7. Beacon Receiver Trouble Shooting...15 MoTeC Lap Beacon Manual Contents Introduction...1 Overview...2 Operation...2 ID Number...3 Lap Beacon Use...4 Split Beacon Use...4 Verifying Operation...5 Beacon Transmitter...7 Position...7 Spacing between

More information

LC 2 MOS Precision 5 V Quad SPST Switches ADG661/ADG662/ADG663

LC 2 MOS Precision 5 V Quad SPST Switches ADG661/ADG662/ADG663 a FEATURE +5 V, 5 V Power upplies Ultralow Power issipation (

More information

Ultramini clever reliability in confined quarters. Simple installation and operation

Ultramini clever reliability in confined quarters. Simple installation and operation Series OU Ultramini clever reliability in confined quarters m Through-beam sensors OUS/OUE up to, m Retro-reflective sensors OUR up to, m Retro-reflective sensors with polarizing filters OUP and OUC up

More information

Digimax 210. Programmable Thermostat. User Guide

Digimax 210. Programmable Thermostat. User Guide Digimax 210 Programmable Thermostat User Guide Schema of the thermostat The RF DigiMax 210 thermostat does not need any extra wiring and works within 30 meters range around the receiver RF-Max. The DigiMax

More information

58Khz ACOUSTO MAGNETIC SYSTEMS WIRING HANDBOOK

58Khz ACOUSTO MAGNETIC SYSTEMS WIRING HANDBOOK 58Khz ACOUSTO MAGNETIC SYSTEMS WIRING HANDBOOK E.A.S. SISTEMAS ANTIHURTO, S.L. 1 Revisión 1 06/2012 1. INTRODUCTION. 2. SYSTEM DESCRIPTION. a. TRANSMITER ANTENNA TX. b. RECEIVER ANTENNA RX. c. POWER SUPPLY.

More information

Programmable Digital Timer

Programmable Digital Timer Digital 7-egment display upply Voltage range of 110-240 VAC Input ignal ensing range of 85-265 VAC/100-265 VDC & 20-60 VAC/DC Inbuilt library of 33 functions covering majority applications Easy steps to

More information

UNICONT. PMG-400 Universal controller and display unit USER'S AND PROGRAMMING MANUAL 1. pmg4111a0600p_01 1 / 24. ST edition

UNICONT. PMG-400 Universal controller and display unit USER'S AND PROGRAMMING MANUAL 1. pmg4111a0600p_01 1 / 24. ST edition UNICONT PMG-400 Universal controller and display unit USER'S AND PROGRAMMING MANUAL 1 ST edition pmg4111a0600p_01 1 / 24 TABLE OF CONTENTS 1. GENERAL DESCRIPTION... 3 2. ORDER CODE... 3 3. TECHNICAL DATA...

More information

TELECRANE REMOTE CONTROLS F21 12/6 S/D MANUAL

TELECRANE REMOTE CONTROLS F21 12/6 S/D MANUAL November 7, 2004 Ref: TCM260904 Rev: 0.1 111 Woodhurst Road, Stanground, Peterborough, Cambridgeshire. PE2 8PQ United Kingdom. Tel: 07092 242773 Fax: 07092 182470 mark@mlhservices.co.uk TELECRANE REMOTE

More information

FLUX 11 Pocket installation manual SENSITIVE INDUCTIVE LOOP DECTOR

FLUX 11 Pocket installation manual SENSITIVE INDUCTIVE LOOP DECTOR FLUX 11 Pocket installation manual SENSITIVE INDUCTIVE LOOP DECTOR 1. Introduction The FLUX 11 is a single channel plug-in inductive loop detector designed for vehicle access applications, and interfaces

More information

General Notes Using Wireless devices

General Notes Using Wireless devices General tes The best first step is to read *22 and *25 to see what is enabled. If these are wrong, this is probably the problem. Next verify the dip-switches and wiring connections. See below for more

More information

Geo EasyTrack Auto Tracking System for Line Lasers

Geo EasyTrack Auto Tracking System for Line Lasers DE EN FR Geo EasyTrack Auto Tracking System for Line Lasers USER MANUAL I www.geo-fennel.de www.geo-fennel.com www.geo-fennel.fr DE Dear customer, Thank you for your confidence in us having purchased a

More information

Transmitter Programming Guide

Transmitter Programming Guide Model PRO-OE4BS This transmitter makes use of icons (symbols) to identify the reaction your system will have when any icon (button) is pressed. These icons are programmed at time of installation to meet

More information

S18 Sensors dc-voltage Series

S18 Sensors dc-voltage Series 8 ensors dc-voltage eries elf-contained dc-operated sensors Features Featuring Z-BM technology for reliable sensing without the need for adjustments ompletely epoxy-encapsulated to provide superior durability,

More information

Introduction Pag. 1. Function and location of the controls Pag. 2. Installation Pag. 3. Power supply Pag. 3. Installing an antenna Pag.

Introduction Pag. 1. Function and location of the controls Pag. 2. Installation Pag. 3. Power supply Pag. 3. Installing an antenna Pag. ALAN 121 INDEX Introduction Pag. 1 E N G L I S H Function and location of the controls Pag. 2 Installation Pag. 3 Power supply Pag. 3 Installing an antenna Pag. 4 How to operate with your transceiver Pag.

More information

Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter

Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter Hardware Installation Guide First Edition, August 2013 2013 Moxa Inc. All rights reserved. P/N: 1802012800011 Introduction The ICF-1280I series

More information

Radio Touch Order no.: 2880 xx. Operation and installation instructions. 1 Safety instructions. 2 Structure of the device (Figure 1) Radio Touch

Radio Touch Order no.: 2880 xx. Operation and installation instructions. 1 Safety instructions. 2 Structure of the device (Figure 1) Radio Touch Radio Touch Order no.: 2880 xx Operation and installation instructions 1 Safety instructions Electrical equipment must only be installed and assembled by a qualified electrician in accordance with the

More information

PANEL-SERVICE CHT SCREW G U (4) PLATE-WALL CHT SCREW G U (2) PLATE-WALL CHT CHT SCREW

PANEL-SERVICE CHT SCREW G U (4) PLATE-WALL CHT SCREW G U (2) PLATE-WALL CHT CHT SCREW PNE-SEV -0-HT G-0-0U () PTE-W 9--HT G-0-0U () P SWITH-STEITE 0-0-HT ETI PTE-W 9--HT 9-0-HT G-0-0U () P PNE SM-VINY OVEE -0-XXX KET-0V ONNE,MOUNT -0-HT P- (ET ) ST PEP E SWITH-STEITE P- (PU) OVH P- (PU)

More information

CIPHERLAB 1166 Bluetooth Scanner

CIPHERLAB 1166 Bluetooth Scanner CIPHERLAB 1166 Bluetooth Scanner THESE SIX PAGES ARE IMPORTANT. Keep handy, perhaps laminated. The notes will save trawling through the enclosed disc. Encourage all personnel to spend a little time to

More information

SGD 2000/2500 Assembly

SGD 2000/2500 Assembly S 2000/2500 ssembly 03/05 0200330 S 2000/2500 SSEY ENER Protect mainframe only with light coating of oil, grease or soap. ction of lime in plaster can destroy finish. Sill must be smooth...buff edges and

More information

NOT RECOMMENDED FOR NEW DESIGNS RECOMMENDED REPLACEMENT PART ISL22102 contact our Technical Support Center at INTERSIL or

NOT RECOMMENDED FOR NEW DESIGNS RECOMMENDED REPLACEMENT PART ISL22102 contact our Technical Support Center at INTERSIL or NO EOMMENE FO NE EIGN EOMMENE EPEMEN P I contact our echnical upport enter at -888-INEI or www.intersil.com/tsc ow Noise, ow ost, High End Features, ual udio og Potentiometer ual udio ontrol igitally ontrolled

More information

Chapter. F0-04AD-1, 4-Channel Analog Current Input. In This Chapter...

Chapter. F0-04AD-1, 4-Channel Analog Current Input. In This Chapter... F0-0-, -hannel nalog urrent Input hapter In This hapter... Module Specifications... Setting the Module Jumper... onnecting and isconnecting the Field Wiring... Wiring iagram... Module Operation... Special

More information

FCC ID: SAGA1-L8 IC: 2802A-SAGAL8 CE0470

FCC ID: SAGA1-L8 IC: 2802A-SAGAL8 CE0470 FCC ID: SAGA1-L8 IC: 2802A-SAGAL8 CE0470 WARRANTY INMOTION Controls, Inc. guarantees that this product meets its published specification at the time of shipment from the factory. Under proper installation,

More information

INCOMING SELECTOR CIRCUITS FROM PANEL LOCAL, OFFICE TANDEM AND PANEL SENDER TANDEM OFFICES MANUAL TEST USING TEST SET ES OR ES

INCOMING SELECTOR CIRCUITS FROM PANEL LOCAL, OFFICE TANDEM AND PANEL SENDER TANDEM OFFICES MANUAL TEST USING TEST SET ES OR ES BELL SYSTEM PRACTICES Plant Series INCOMING SELECTOR CIRCUITS FROM PANEL LOCAL, OFFICE TANDEM AND PANEL SENDER TANDEM OFFICES MANUAL TEST USING TEST SET ES-20150-01 OR ES-239844,,, I' I Issue 3, November,

More information

Hidden Camera Surveillance

Hidden Camera Surveillance + Hidden Camera Surveillance Tel 1300 763235 Wireless Solar Gate & Driveway Alert The Wireless Gate Alert kit is a simple DIY solar powered point to point photoelectric invisible beam which can be up to

More information

Model WHD Weld Hole Detector Operator s Manual. Rev 1.1

Model WHD Weld Hole Detector Operator s Manual. Rev 1.1 Model WHD Weld Hole Detector Operator s Manual Rev 1.1 Contents 1. Introduction... 2 2. Description... 2 2.1 Model Nomenclature... 2 2.2 Operating Principle... 2 2.3 Specifications... 3 3. Location and

More information

INSTALLATION AND SETUP GUIDE

INSTALLATION AND SETUP GUIDE INSTALLATION AND SETUP GUIDE K4460V3 4/06 Rev A 6150RFPL2 Keypad/Transceiver GENERAL INFORMATION The 6150RFPL2 Keypad/Transceiver is a combination unit incorporating a normally-open relay output and the

More information

Supply 12Vdc nominal (9 Vdc minimum, 14,5Vdc maximum ) Max Current Drain. from a , V Carrier Frequency

Supply 12Vdc nominal (9 Vdc minimum, 14,5Vdc maximum ) Max Current Drain. from a , V Carrier Frequency MIX400 48 CHANNELS WIRELESS RECEIVER ON 8 OUTPUTS TECHNICIAN MANUAL ENGLISH DESCRIPTION Mix 400 is a 48 channel universal wireless receiver, memorizable and free assignable on 8 open-collector outputs.

More information

$ 12 $ 11. Terminal Block Relays (cont d) Interface PCB Relays with Socket. Why customers choose FactoryMation over competitors

$ 12 $ 11. Terminal Block Relays (cont d) Interface PCB Relays with Socket. Why customers choose FactoryMation over competitors 92 REAY www.facorymaion.com/relays Terminal Block Relays (con d) $ 12 V D E Feaures: Changeover relay, raed load 6A/230V(ACI) lim DI-rail moun socke wih buil-in ED posiion indicaor Descripion plae Opional

More information

laser sensors through-beam sensor switching output / analog output high precision repeatability

laser sensors through-beam sensor switching output / analog output high precision repeatability through-beam sensors 1600 design M8x1 M12x1 M18x1 through-beam sensor operating distance 1.5m 3.0m 5.0m 60.0m recognition of smallest objects high sampling frequency up to 25kHz external adjustable laser

More information

MK372/Ultrasonic Sensor System. Installation & Setting up Instructions. Comprising. MK372 Indicator/Controller Ultrasonic Transmitter

MK372/Ultrasonic Sensor System. Installation & Setting up Instructions. Comprising. MK372 Indicator/Controller Ultrasonic Transmitter MK372/Ultrasonic Sensor System Installation & Setting up Instructions Comprising MK372 Indicator/Controller Ultrasonic Transmitter 1 Contents page Page 1.0 Overview 3 2.0 General Specification MK372 4

More information

Wireless Temp/Setpoint & Override Room Transmitter

Wireless Temp/Setpoint & Override Room Transmitter Overview The BAPI Wireless Combination Transmitter measures the room temperature and relative humidity and transmits the data at 418MHz or 433MHz RF to a receiver. Temperature setpoint and override button

More information

RF3405E. Installation Instructions Wireless (RF) Inertia Transmitter

RF3405E. Installation Instructions Wireless (RF) Inertia Transmitter RF405E EN Installation Instructions Wireless (RF) Inertia Transmitter NeverReady Batteries, Inc. Lost Power, NV RF405E Installation Instructions.0 General Information EN Installation Instructions Figure

More information

Lock And Arm Alarm, also initiate and terminates *Panic.

Lock And Arm Alarm, also initiate and terminates *Panic. Model 095BPr Transmitter Programming Guide These transmitters use icons (symbols) to identify the reaction your security system, keyless entry, and/or remote start system, where applicable, will have when

More information

MA5B 20 / 17 / 15 / 12 / 10 Meter Beam Antenna

MA5B 20 / 17 / 15 / 12 / 10 Meter Beam Antenna ASSEMBLY AND INSTALLATION INSTRUCTIONS NE 20 / 17 / 15 / 12 / 10 Meter Beam Antenna 951485_GF_AB WARNING THIS ANTENNA IS AN ELECTRICAL CONDUCTOR. CONTACT WITH POWER LINES CAN RESULT IN DEATH, OR SERIOUS

More information

Two-Way Radio Model MT 600

Two-Way Radio Model MT 600 Two-Way Radio Model MT 600 ENGLISH 1 10 9 2 3 4 1. Antenna 2. External Speaker/ Microphone/Charge Jack 3. Mode/Power Button 4. Lock Button 5. Channel Select Buttons 6. Speaker/Microphone 7. Light/Max Range

More information

Two-Way Radio Model MT 925 PRO

Two-Way Radio Model MT 925 PRO Two-Way Radio Model MT 925 PRO ENGLISH Antenna External Speaker/ Microphone Jack ON-OFF/VOLUME Knob Power/Transmit-Receive Indicator TALK Button CHANNEL UP/ CHANNEL DOWN Buttons LIGHT/MAX RANGE Button

More information