General Notes Using Wireless devices

Size: px
Start display at page:

Download "General Notes Using Wireless devices"

Transcription

1 General tes The best first step is to read *22 and *25 to see what is enabled. If these are wrong, this is probably the problem. Next verify the dip-switches and wiring connections. See below for more detailed information. Also, don t overlook the basics: check the panel AC, battery, etc If anything at all goes wrong with the panel the Check 09 may be the symptom. This is because the expansion modules are supervised and other devices are not. For example, a problem with a keypad could cause a problem on the ECP data bus. Because the keypad is not supervised, no trouble condition is associated with this. However, the ECP problem could cause a communication problem to the expanders and therefore result in a Check 09. Using Wireless devices Verify the dip-switches on the RF expander. Switches should be set with switch all OFF (address 00). Toggle the dip-switches (off, then back on) this will ensure that they are seated properly. There is no cover tamper on the 4281 or 5881 receiver. Verify the model number of the RF receiver Verify that *22 = 1 if Using a 5881 Verify that *22 = 4 if Using a 5881 with RF jam detection enabled. (only applies to panels that have the rf jam feature) Verify that *25 = 0 (If there is not a 4219/4229/4204 in use) Verify wiring to the RF receiver from the control panel. The plug-in harness should be wired as follows: Panel Terminal Receiver wire 4 Black wire 5 Red wire 6 Green wire 7 Yellow wire To verify the integrity of the wire harness, try to operate a keypad from the same harness; or replace the harness. It is important that the data wires for the receiver not t-tap to go to other devices. The receiver should have its own home-run wire to the control panel. Refer to Wire run limitations for the expanders Remove all other ECP devices and wires except a keypad and the RF receiver to isolate the system. Check voltages on the data wires. With reference to black, you should read: Red = 13.5VDC Yellow = VDC (fluctuating) Green = a few millivolts with some fluctuation If these are not correct, see if the voltages are correct at the panel, and troubleshoot the wiring. Move the receiver to the control panel and retest. 1

2 Using a hardwire expander (4219/429/4204 relay module) te: only one of these devices may be used. Verify the dip-switches on the device. Switches should be set with switch 2 OFF, 3/4/5 ON (address 01). 4204: Dip 1=tamper (Enabled = off (left)) 4219/4229: Dip1 = zone response time for zone 10. This will not affect a Check 09 condition. Toggle the dip-switches (off, then back on) this will ensure that they are seated properly. If using the cover tamper, make sure the magnet is installed in the cover and the cover is secure. It may be helpful to disable the tamper until the problem is corrected, to minimize possible causes of this trouble. The tamper on the 4219/4229 may be enabled/disabled by a jumper in the corner of the PCB at the end of the zone terminals opposite from the ECP connections. te: The tamper on the 4219/4229 is disabled when the jumper is away from the edge of the PCB.The tamper on the 4204 may be disabled by turning switch 1 ON Verify that *22 = 0 (if wireless is not used) Verify that *25 = 1 If using a 4219 zone expander Verify that *25 = 2 If using a 4229 zone expander with relays Verify that *25 = 3 If using a 4204 relay module Verify wiring to the expander from the control panel. te: If using the plug-in harness ensures that yellow is close to the edge of the expander PCB. The wiring should be as follows: Panel Terminal Expander Terminal/wire color 4 15 (or Black wire) 5 13 (or Red wire) 6 14 (or Green wire) 7 16 (or Yellow wire) It is important that the data wires for the expander not loop through it or t-tap to go to other devices. Each expander should have its own home-run wire to the control panel. Refer to Wire run limitations for the expanders Check voltages on the data wires. With reference to black, you should read: Red = 13.5VDC Yellow = VDC (fluctuating) Green = a few millivolts with some fluctuation te:if these are not correct, see if the voltages are correct at the panel, and troubleshoot the wiring. Move the expander to the control panel and retest. Remove all other ECP devices and wires except a keypad and the expander to isolate the system. 2

3 Try setting *25=0 as a test to verify that check 09 does clear. Assuming that it does, set *25 back again. Using Both Wireless and an expansion module The toughest part of this combination is figuring out which device has the problem. Check the dip-switches and wiring as indicated in the sections above and test voltages as indicated. Check *22 and *25 to ensure they are correct. Try to determine if either module is working or not working: Do the wireless zones work? Do the relays work? te: If this has not cleared the problem, try isolating the system by removing one device (physically and from programming). If you disable the RF receiver by setting *22=0, you will loose all of your serial numbers. Therefore, it is less painful to start by removing the expander and setting *25=0 first to see if that clears the trouble. Using neither wireless or 4204 relay module Verify that *22 = 0 Verify that *25 = 0 (unless there is an Alarmnet in 4204 emulation mode) Using an Alarmnet radio backup in 4204-emulation mode Using an Alarmnet radio backup in 4204-emulation mode In this application, the Alarmnet acts exactly like a 4204 to the control panel. A Check 09 can be caused by a communication failure between the radio and the control panel. A Check 09 can be caused by some other problem with the Alarmnet such as: Power (AC/battery), temper, communication error to Alarmnet Using an RF keypad (6128RF/6150RF) If using a 6128RF or 6150RF for key-fobs in the local mode only, you must: - Set *22 = 0(because you have chosen to use the keypad receiver) - Set the RF keypad for its local mode in its internal programming. - Refer to the installation instructions for the keypad for more information. te: If you are using the RF keypad in both the system and local modes, and you enter the local program mode of the keypad, the keypads receiver is no longer talking to the control panel. This will generate a Check 09 condition that can be cleared by keying a code + off twice. 3

4 Wire run limitations for the expanders The following limits have been calculated based on the current draw of these devices: AWG 4204 using 4204 using 4204 using 4204 using relay 2 relays 3 relays 4 relays (using relays) 22 AWG AWG AWG AWG te: The sum of all wires on the ECP (keypad) bus cannot exceed 1500 (750 if using shielded wire or metallic conduit) due to capacitive effects. The above limitations are based on the power for the device. If using a power supply located close to the device, the data wires to the control panel may be up to 1500 regardless of the wire size. In this case, remember that you must have a common ground to the control panel. RF Jamming explanation If something jams the RF receiver with a continuous signal it can interfere with the receiver s ability to receive signals from the transmitters. If this continues for a 12- hour period, and the control panel has not received signals from any transmitters, the system will assume there is a problem with the receiver and report a Check 09. In this case, all supervised transmitters will also be in Check. This is usually indicated by the red LED on the receiver flickering or glowing continuously. The newest 5881 receivers (PCB marked 5882) have the ability to detect an RF jamming condition. This feature can be detected in the control panel (revision 13 and higher) by setting *22=4. The control panel would report a Check 90 condition if a jamming condition lasts for more than 20 seconds. Check 09 that comes and goes (intermittent) This can be difficult to troubleshoot because it is probably OK right now. The following questions may give you the answers you need to isolate the problem when applied to the information given previously. If using wireless are any RF zones in trouble? Are they supervised? Do the wireless zones work? Test wiring/look at total ECP configuration. Look on Next Page for a Troubleshooting flow Chart! 4

5 Check 09 Using Wireless or 4219/4229/4204? Do the Zones/Relays work? Field 22=? Field 25=? If not 0 they need to be made /5882/ /4229/4204 Check your 4219/4229 if using one! Check the Address! Tamper? Voltage? B/R, B/G, B/Y More than 1 wireless receiver. Check for a 6128/50rf keypad. Good Bad Tamper? On a Commercial Grade Receiver or 6150rf. Aux Power Supply? NO Check Wiring Harness. On 4219 Wire to Terminals. Disabled *22 = 0? Enabled Check the Magnet Disable if not wanted Common Ground? Check Wire Run. Bring Back to Panel. Possible Bad Product! Using 4219/4229, or Wireless? Neg. on P.S. to Neg. on 5 Control. Call Tech Support!

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS K4460V2 3/01 6150RFPL2 Keypad/Transceiver About the 6150RFPL2 The 6150RFPL2 is a combination unit that contains: A 6150PL2 Fixed Addressable Keypad A 5800TM Transmitter Module

More information

INSTALLATION AND SETUP GUIDE

INSTALLATION AND SETUP GUIDE INSTALLATION AND SETUP GUIDE K4460V3 4/06 Rev A 6150RFPL2 Keypad/Transceiver GENERAL INFORMATION The 6150RFPL2 Keypad/Transceiver is a combination unit incorporating a normally-open relay output and the

More information

INSTALLATION AND SETUP GUIDE

INSTALLATION AND SETUP GUIDE INSTALLATION AND SETUP GUIDE K4460-1V6 2/06 Rev C ADEMCO 6150RF Keypad/Transceiver GENERAL INFORMATION The 6150RF Keypad/Transceiver is a combination unit incorporating a normally-open relay output and

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS K4456V1 8/00 FA260RF Keypad/Transceiver About the FA260RF The FA260RF is a combination unit that contains: A FA260KP Fixed Addressable Keypad A 5800TM Transmitter Module A 5881M

More information

Com-Trol ADV-6000 Trouble Shooting Guide Click on red text to go to that page in guide

Com-Trol ADV-6000 Trouble Shooting Guide Click on red text to go to that page in guide Com-Trol ADV-6000 Trouble Shooting Guide Click on red text to go to that page in guide Topic Introduction 1 Tool Requirements 1 Trouble Shooting Check List 1 Page(s) Lost communications to controller(s)

More information

Quik Bridge Loop Receiver Installation Instructions

Quik Bridge Loop Receiver Installation Instructions Quik Bridge Loop Receiver Installation Instructions Support for a piezo (used for RF testing only) which, when used sounds the number of transmissions received from learned transmitters. Compatibility

More information

Operating Instructions

Operating Instructions LR650 Operating Instructions This product is an accessory or part of a system. Always read and follow the manufacturer s instructions for the equipment you are connecting this product to. Comply with all

More information

G703. Installation instructions. residential gate opener for sliding gates. remote control openers security at your fingertips

G703. Installation instructions. residential gate opener for sliding gates. remote control openers security at your fingertips remote control openers security at your fingertips G703 residential gate opener for sliding gates Installation instructions Toll free helpline Please have your serial number and model name available before

More information

Blue Point Engineering

Blue Point Engineering Overview Blue Point Instruction Board 2-CH Boards, Terminal Block and Ribbon Cable I Type: RF Radio (315 MHz) 1-2 Channels (FCC Part 15 Compliant Components). Operating Voltage: 6-15 VDC @ 1 Amp (Wall

More information

Home Automation, Inc. Model 12A00. Wireless Receiver. Installation Manual

Home Automation, Inc. Model 12A00. Wireless Receiver. Installation Manual Home Automation, Inc. Model 12A00 Wireless Receiver Installation Manual Document Number 12I00 Rev D August, 2002 CONTENTS DESCRIPTION...1 COMPATIBLE TRANSMITTERS...1 INSTALLATION...2 OPERATION...3 SETUP

More information

SCHLAGE WIRELESS ACCESS SYSTEM (WAS)

SCHLAGE WIRELESS ACCESS SYSTEM (WAS) CONFIGURING & OPERATING INSTRUCTIONS SCHLAGE WIRELESS ACCESS SYSTEM (WAS) The most current version of this document is available for download at: http://www.ir-swa.com P/N: M053-007-D Schlage 245 W. Roosevelt

More information

Dakota Alert. WPT-3000 Wireless Probe Transmitter. Owner s Manual

Dakota Alert. WPT-3000 Wireless Probe Transmitter. Owner s Manual Dakota Alert WPT-3000 Wireless Probe Transmitter Owner s Manual Warnings This device complies with Part 15 of the FCC rules, operation of this device is subject to the following conditions: 1. This device

More information

Blue Point Engineering Inc.

Blue Point Engineering Inc. Engineering Inc. ireless Radio Control of Puppets Setup Overview RF Control C Pointing the ay to Solutions! Hardware Setup Overview Page 1 Servo No.1 Servo No.2 Control Signal Line RX8ch1,2 Servo Board

More information

Heritage MedCall. Sentry E-Call Model HM-527 Resident Host Panel

Heritage MedCall. Sentry E-Call Model HM-527 Resident Host Panel Heritage MedCall Sentry E-Call Model HM-527 Resident Host Panel 430-527B 0305 Heritage MedCall, Inc. Issue 1, March 2005 Heritage Medcall Sentry Emergency Call System Model 527 Host Panel Installation

More information

WPT-1000 Wireless Probe Transmitter. Owner s Manual

WPT-1000 Wireless Probe Transmitter. Owner s Manual WPT-1000 Wireless Probe Transmitter Owner s Manual Compliance Complies with AS/NZS 4268 of 2003 Installation: The WPT-1000 transmitter is used with the Farm Alarm WR-1000 receiver. The WPT-1000 transmitter

More information

7835CF. Cellular Control Channel Transceiver for Fire ,QVWDOODWLRQDQG6HWXS*XLGH 12: 352 (1$%/(' K3204-1V2 9/99 352*5$00(5/(66 5(*,675$7,21 237,21

7835CF. Cellular Control Channel Transceiver for Fire ,QVWDOODWLRQDQG6HWXS*XLGH 12: 352 (1$%/(' K3204-1V2 9/99 352*5$00(5/(66 5(*,675$7,21 237,21 7835CF Cellular Control Channel Transceiver for Fire,QVWDOODWLRQDQG6HWXS*XLGH 12: 352 (1$%/(' 352*5$00(5/(66 5(*,675$7,21 237,21 K3204-1V2 9/99 7DEOHRI&RQWHQWV List of Terms...2 Section 1. General Information...3

More information

1100DH High Power Wireless Receiver

1100DH High Power Wireless Receiver 00DH High Power Wireless Receiver INSTALLATION GUIDE Description The 00DH High Power Wireless Receiver provides two-way, supervised communication using 900 MHz frequencyhopping spread-spectrum technology.

More information

GROUP OF COMPANIES. MERLIN STEALTH Electric Fence Energizer INSTALLERS MANUAL

GROUP OF COMPANIES. MERLIN STEALTH Electric Fence Energizer INSTALLERS MANUAL GROUP OF COMPANIES MERLIN STEALTH Electric Fence Energizer INSTALLERS MANUAL Revision 1.5 23 February 2007 : INSTALLERS MANUAL Table of Contents 2 INTRODUCTION.. 3 INSTALLER OPTIONS...... 4-11 ALARM SETTING

More information

H7625A, H7635A, H7626A, H7636A Series 2000 Humidity/Temperature Sensors

H7625A, H7635A, H7626A, H7636A Series 2000 Humidity/Temperature Sensors H765A, H765A, H766A, H766A Series 000 Humidity/Temperature Sensors WALL-MOUNT MODELS INSTALLATI INSTRUCTIS APPLICATI The H765A, H766A, H765A and H766A Wall-Mount Humidity/Temperature Sensors are universal

More information

MEGA REMOTE RADIO REMOTE CONTROL SYSTEM

MEGA REMOTE RADIO REMOTE CONTROL SYSTEM RADIO REMOTE CONTROL SYSTEM -PRELIMINARY- INSTALLATION AND OPERATION MANUAL NORWOOD 3A2481CJ.doc April 15, 2014 BJ INDEX DESCRIPTION... 2 TRANSMITTER AND RECEIVER SYNCHRONIZATION... 3 CLONING TRANSMITTERS...

More information

WPT-3000 Wireless Probe Transmitter. Owner s Manual

WPT-3000 Wireless Probe Transmitter. Owner s Manual WPT-3000 Wireless Probe Transmitter Owner s Manual Warnings This device complies with Part 15 of the FCC rules, operation of this device is subject to the following conditions: 1. This device may not cause

More information

H7625A, H7635A, H7626A, H7636A Series 2000 Humidity/Temperature Sensors

H7625A, H7635A, H7626A, H7636A Series 2000 Humidity/Temperature Sensors H765A, H7635A, H766A, H7636A Series 000 Humidity/Temperature Sensors WALL-MOUNT MODELS APPLICATI The H765A, H766A, H7635A and H7636A Wall-Mount Humidity/Temperature Sensors are universal Relative Humidity

More information

RF3405E. Installation Instructions Wireless (RF) Inertia Transmitter

RF3405E. Installation Instructions Wireless (RF) Inertia Transmitter RF405E EN Installation Instructions Wireless (RF) Inertia Transmitter NeverReady Batteries, Inc. Lost Power, NV RF405E Installation Instructions.0 General Information EN Installation Instructions Figure

More information

Lab. I Electrical Measurements, Serial and Parallel Circuits

Lab. I Electrical Measurements, Serial and Parallel Circuits Name (last, first) ECE 2100 ID Lab. I Electrical Measurements, Serial and Parallel Circuits Pre-Lab Important note: this is the pre-lab of Lab I. You can type in the answers, or print out and write in

More information

ZONEX. Validation Process. Point Identification Validation

ZONEX. Validation Process. Point Identification Validation ZONEX EN Validation Process Point Identification Validation ZONEX Validation Process Contents Contents 1.0 Introduction...3 1.1 Purpose...3 1.2 Recommended Tools and Their Uses...3 1.3 Commands/Memory

More information

GSM-900 Contact ID Cellular Backup System Installation Manual

GSM-900 Contact ID Cellular Backup System Installation Manual GSM-900 Contact ID Cellular Backup System Installation Manual Rev. 1.01-08/11/08 Table of Contents Introduction... 3 1.0 Parts Needed to Complete this Installation... 3 2.0 Activation and Installation...

More information

DCPT-2500 Wireless Probe Transmitter. Owner s Manual

DCPT-2500 Wireless Probe Transmitter. Owner s Manual DCPT-2500 Wireless Probe Transmitter Owner s Manual DCPT-2500 Manual.indd 1 5/5/2010 3:04:05 PM Warnings This device complies with Part 15 of the FCC rules, operation of this device is subject to the following

More information

CP/RX INSTALLATION INSTRUCTIONS. Multi-Mode Radio Receiver and Timing Module HDRC

CP/RX INSTALLATION INSTRUCTIONS. Multi-Mode Radio Receiver and Timing Module HDRC HDRC ISTLLTI ISTRUCTIS Section 1 General Description The is a sophisticated radio control receiver and timing module. This single device provides 3 selectable frequencies: High Definition Radio Control

More information

INSTALLATION INSTRUCTIONS FOR THE CLIKCARD COMMERCIAL RECEIVER (NARROW BAND)

INSTALLATION INSTRUCTIONS FOR THE CLIKCARD COMMERCIAL RECEIVER (NARROW BAND) Doc. 6001200 Rev. B INSTALLATION INSTRUCTIONS FOR THE CLIKCARD COMMERCIAL RECEIVER (NARROW BAND) TABLE OF CONTENTS TABLE OF CONTENTS...1 INSTALLATION FOR INFINITY AND PROCARD...3 PULLING CABLE... 3 MOUNTING

More information

ICS REPEATER CONTROLLERS

ICS REPEATER CONTROLLERS ICS REPEATER CONTROLLERS BASIC CONTROLLER USER MANUAL INTEGRATED CONTROL SYSTEMS 1076 North Juniper St. Coquille, OR 97423 Email support@ics-ctrl.com Website www.ics-ctrl.com Last updated 5/07/15 Basic

More information

AKR-1. Digital Keyless Entry System With Built-in Wireless Receiver. Installation and Programming Instructions

AKR-1. Digital Keyless Entry System With Built-in Wireless Receiver. Installation and Programming Instructions AKR-1 Digital Keyless Entry System With Built-in Wireless Receiver Installation and Programming Instructions (760) 438-7000 FAX (760) 438-7043 USA & Canada (800) 421-1587 & (800) 392-0123 Toll Free FAX

More information

Proximity-Sensor Counter Installation Instruction Model: MRC-PRO

Proximity-Sensor Counter Installation Instruction Model: MRC-PRO Proximity-Sensor Counter Installation Instruction Model: MRC-PRO NYS DOT Approval SYSDYNE CORP. 1055 Summer St. 1 st Floor Stamford, CT 06905 Tel: (203)327-3649 Fax: (203)325-3600 Contents: Introduction...

More information

WARRANTY. Long Range Systems, LLC, 20 Canal St, Suite 4N, Franklin, NH 03235

WARRANTY. Long Range Systems, LLC, 20 Canal St, Suite 4N, Franklin, NH 03235 WARRANTY Long Range Systems, Inc. warrants the trap release product against any defects that are due to faulty material or workmanship for a one-year period after the original date of consumer purchase.

More information

EN4232MR 32 Zone Multi-Condition Receiver with Relay Outputs Installation and Operation Manual

EN4232MR 32 Zone Multi-Condition Receiver with Relay Outputs Installation and Operation Manual EN4232MR 32 Zone Multi-Condition Receiver with Relay Outputs Installation and Operation Manual 1 Overview The EN4232MR receiver allows you to add up to 32 transmitters and 11 outputs to any application,

More information

BCV-1203 Barcode Verification System Users Guide Version 1.2

BCV-1203 Barcode Verification System Users Guide Version 1.2 BCV-1203 Barcode Verification System Users Guide Version 1.2 6 Clock Tower Place Suite 100 Maynard, MA 01754 USA Tel: (866) 837-1931 Tel: (978) 461-1140 FAX: (978) 461-1146 http://www.diamondt.com/ Liability

More information

CARSON MANUFACTURING CO., INC NORTH RURAL STREET INDIANAPOLIS, IN (888) TECHNICAL BULLETIN

CARSON MANUFACTURING CO., INC NORTH RURAL STREET INDIANAPOLIS, IN (888) TECHNICAL BULLETIN Carson MANUFACTURING COMPANY, INC. CARSON MANUFACTURING CO., INC. 5451 NORTH RURAL STREET INDIANAPOLIS, IN 46220 (888) 577 6877 www.carsonsirens.com TECHNICAL BULLETIN RADIO MAN SIREN PA VOL WAIL YELP

More information

IR Troubleshooting Guide

IR Troubleshooting Guide IR Troubleshooting Guide NOTE: Due to the many variables in a given installation, the troubleshooting countermeasures you will have to take may vary from job to job. Each installation is different due

More information

Ness MCR Multi-Channel Radio Receiver

Ness MCR Multi-Channel Radio Receiver Installer s MANUAL Ness MCR Multi-Channel Radio Receiver Installation and programming manual Revision 2.1 www.nesscorporation.com National Customer Service Centre Ph: 1300 551 991 customerservice@ness.com.au

More information

Installation Manual. UL 325 Compliant. For Pre-2016 Convenience Open Operators ONLY

Installation Manual. UL 325 Compliant. For Pre-2016 Convenience Open Operators ONLY CFORMS TO ANSI/UL- CERTIFIED TO CAN/CSA C.. CLASS MODEL SERIAL HP CFORMS TO ANSI/UL- CERTIFIED TO CAN/CSA C.. CLASS MODEL SERIAL HP CLASS MODEL SERIAL HP Installation Manual Use this manual for circuit

More information

Wireless Data Gathering Panel (DGP) Model AL-1231

Wireless Data Gathering Panel (DGP) Model AL-1231 g GE Security Wireless Data Gathering Panel (DGP) Model AL-1231 Installation & Programming Guide Installation and Programming Guide Wireless DGP AL-1231 Part number: 466-2025-US Rev. H April 2005 Contents

More information

Wireless Programmer for Wireless Sensor System

Wireless Programmer for Wireless Sensor System R INSTALLATION AND OPERATION INSTRUCTIONS Wireless Programmer for Wireless Sensor System FOR PLATINUM CONTROLS WITH COMMUNICATION Connect to other Wireless units LED Green = in operation Red = charging

More information

T5x Error Codes DGC5X Console Board W/ ACD3X LCB

T5x Error Codes DGC5X Console Board W/ ACD3X LCB 1000320 Rev 2 4/18/06 T5x Error Codes DGC5X Console Board W/ ACD3X LCB Table of Contents Page # Error Code Description 2 Service Information 2-3 Serial Number Information 2 Manager Mode & Engineering Mode

More information

HL25K INSTALLATION INSTRUCTIONS. Hidden Link Shelf Top Standard IR Receiver

HL25K INSTALLATION INSTRUCTIONS. Hidden Link Shelf Top Standard IR Receiver DESCRIPTION The Hidden Link IR Receiver is a small shelf-top infrared repeater assembly. It includes an IR receiver. a 789-44 Connecting Block, a Power supply, and 4 283D emitters. The Hidden Link IR Receiver

More information

670K9 SORtrax Level Transmitter

670K9 SORtrax Level Transmitter SORtrax is a 4-20 ma continuous level transmitter. It produces a 4-20mA current superimposed on the 12-55 VDC loop supply lines. The 4-20mA current is proportional to the level sensed by the instrument.

More information

BFS / BFSM SERIES Installation & Maintenance Manual

BFS / BFSM SERIES Installation & Maintenance Manual Introduction: The BFS / BFSM series electric actuators have battery backup modules for fail safe operation. The BFS series is for two position control and the BFSM series is for proportional control, both

More information

Rain Bird Decoders. Decoders. Troubleshooting

Rain Bird Decoders. Decoders. Troubleshooting Troubleshooting Decoders Rain Bird Decoders Decoders are a cost-effective alternative to traditional in-field controllers. Installed underground and featuring simple, low-cost wiring, decoders are an aesthetically

More information

XT-DL-IRK. DinkyLink IR Receiver Kit. Plasma / LCD / LED / CFL Friendly IR Receiver INSTALLATION INSTRUCTIONS

XT-DL-IRK. DinkyLink IR Receiver Kit. Plasma / LCD / LED / CFL Friendly IR Receiver INSTALLATION INSTRUCTIONS XT-DL-IRK DinkyLink IR Receiver Kit Plasma / LCD / LED / CFL Friendly IR Receiver INSTALLATION INSTRUCTIONS DESCRIPTION These small IR receivers have been designed for mounting in very small spaces. They

More information

PIM400-TD2. User guide for Panel Interface Module PIM400-TD2

PIM400-TD2. User guide for Panel Interface Module PIM400-TD2 P516-096 PIM400-TD2 User guide for Panel Interface Module PIM400-TD2 Para el idioma español, navegue hacia www.schlage.com/support Pour la portion française, veuillez consulter le site www.schlage.com/support

More information

IC System TM Design Guide v 2.3

IC System TM Design Guide v 2.3 IC System TM Design Guide v 2.3 Updated August 2016 IC System TM Product Definitions... 3 Integrated Control Interface (ICI)... 4 Integrated Control Module (ICM)... 5 Integrated Control Surge Device (ICSD)...

More information

LT3000 ULTRASONIC LEVEL TRANSMITTER

LT3000 ULTRASONIC LEVEL TRANSMITTER LT3000 ULTRASONIC LEVEL TRANSMITTER Owner s Manual Specifications Installation Calibration Troubleshooting Warranty Drawings Distributed By: iprocessmart.com 14262 Doolittle Drive San Leandro, CA 94577

More information

Rev RF Service Tool Operator s Guide

Rev RF Service Tool Operator s Guide 026-1703 Rev 0 7-23-01 RF Service Tool Operator s Guide 1640 Airport Road, Suite 104 Kennesaw, GA 31044 Phone: (770) 425-2724 Fax: (770) 425-9319 ALL RIGHTS RESERVED. The information contained in this

More information

LL-105-R LED Dimmer & 0-10V Bridge Setup Guide

LL-105-R LED Dimmer & 0-10V Bridge Setup Guide www.i2systems.com i2systems is a registered trademark of Integrated Illumination Systems, Inc. LightLink is a trademark of Integrated Illumination Systems, Inc. 2018 Integrated Illumination Systems, Inc.

More information

EN4216MR 16 Zone Multi-Condition Receiver with Relay Outputs Installation and Operation Manual

EN4216MR 16 Zone Multi-Condition Receiver with Relay Outputs Installation and Operation Manual EN4216MR 16 Zone Multi-Condition Receiver with Relay Outputs Installation and Operation Manual 1 Overview The EN4216MR receiver allows you to add up to 16 transmitters and five outputs to any application,

More information

Ness M1RF Wireless Receiver

Ness M1RF Wireless Receiver INSTALLATION MANUAL Ness M1RF Wireless Receiver Specifications, Installation and Programming Page 1 (Version 1.4 - May 2008) Ness Document No. 895-364 APPLICATION The Ness M1RF Receiver is a unique high

More information

Application Note # 5438

Application Note # 5438 Application Note # 5438 Electrical Noise in Motion Control Circuits 1. Origins of Electrical Noise Electrical noise appears in an electrical circuit through one of four routes: a. Impedance (Ground Loop)

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL RADIO/CAN REMOTE CONTROL SYSTEM -PRELIMINARY- INSTALLATION AND OPERATION MANUAL SDP GREEN 3B1151AJ.doc September 3, 2009 AP INDEX DESCRIPTION... 2 TRANSMITTER AND RECEIVER SYNCHRONIZATION... 3 INDICATOR

More information

Activity 3: Wireless Communication Student Handout. Parts Descriptions. Wireless Communications: Wireless Burglar Alarm

Activity 3: Wireless Communication Student Handout. Parts Descriptions. Wireless Communications: Wireless Burglar Alarm Activity 3: Wireless Communication Student Handout Name: Date: For this activity, you will be modifying your wired communication system to make it wireless. In the end, the transmitter/receiver pair will

More information

Wireless Data Gathering Panel MODEL TS0825

Wireless Data Gathering Panel MODEL TS0825 Wireless Data Gathering Panel MODEL TS0825 Wireless Data Gathering Panel: Model TS0825 INSTALLATION GUIDE The TS0825 Wireless Data Gathering Panel may be installed up to 1.5km from the Challenger panel

More information

English RACON SERIES II RADIO CONTROL SERVICE MANUAL

English RACON SERIES II RADIO CONTROL SERVICE MANUAL English 22.2.2007 RACON SERIES II RADIO CONTROL SERVICE MANUAL Read the instructions supplied with the product before installation and commissioning. Keep the instructions in a safe place for future reference.

More information

GLR43308 and GLR2708. Setup and programming instructions. for the 8 channel Gigalink receiver. Programming Videos

GLR43308 and GLR2708. Setup and programming instructions. for the 8 channel Gigalink receiver.   Programming Videos GLR43308 and GLR2708 Setup and programming instructions for the 8 channel Gigalink receiver Programming Videos www.elsema.com NOTES IMPORTANT WARNING AND SAFETY INSTRUCTIONS All installations and testing

More information

FA401 Single Transmitter / Single Output Receiver. FA401R Single Transmitter / Single Relay Output Receiver. Installation Instructions 02305C

FA401 Single Transmitter / Single Output Receiver. FA401R Single Transmitter / Single Relay Output Receiver. Installation Instructions 02305C FA401 Single Transmitter / Single Output Receiver FA401R Single Transmitter / Single Relay Output Receiver Frequency Agile 900MHz Installation Instructions 02305C Note: The FA401 is intended to be installed

More information

Obstruction Lighting Troubleshooting Manual

Obstruction Lighting Troubleshooting Manual Obstruction Lighting Troubleshooting Manual Leaders in LED Lighting & Controls NOTE: USE THIS GUIDE WITH ANY DLS1-008 OR WLS1-008 SYSTEM 3195 Vickery Rd N Syracuse, NY 13212 Ph: (315) 699-4400 or (800)

More information

Rev J Automatic Pitch Trim

Rev J Automatic Pitch Trim Installation Manual For Automatic Pitch Trim TRUTRAK FLIGHT SYSTEMS 1488 S. Old Missouri Road Springdale, AR 72764 POSTAL SERVICE ADDRESS P.O. Box 189 Springdale AR 72765-0189 Ph: 479-751-0250 Fax: 479-751-3397

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-920 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration

More information

HOME COMMUNICATION EQUIPMENT OWNERS MANUAL REV

HOME COMMUNICATION EQUIPMENT OWNERS MANUAL REV System One by HOME COMMUNICATION EQUIPMENT OWNERS MANUAL REV 2 TABLE OF CONTENTS INTRODUCTION....2 Features Include PARTS IDENTIFICATION....3 POWERING UP THE SYSTEM...3 MODE DEFINITIONS.4 Music Mode Monitor

More information

MFJ ENTERPRISES, INC.

MFJ ENTERPRISES, INC. TM Model MFJ-1924 INSTRUCTION MANUAL CAUTION: Read All Instructions Before Operating Equipment! MFJ ENTERPRISES, INC. 300 Industrial Park Road Starkville, MS 39759 USA Tel: 662-323-5869 Fax: 662-323-6551

More information

Pic-Convert Board Instructions

Pic-Convert Board Instructions Pic-Convert Board Instructions This is the fifth version of the Pic-Convert board and now has fully isolated inputs and provides a power supply to make the solution completely industrial. This DAC+PWM

More information

With Audible Detect Signal

With Audible Detect Signal T-100 SERIES SINGLE CHANNEL SHELF MOUNT DETECTOR Meets and exceeds NEMA TS 1 specification. Six front panel DIP switches provide: Seven levels of sensitivity plus off. Presence or Pulse mode. Four loop

More information

Radio Control Installation and Operating Instructions System 4

Radio Control Installation and Operating Instructions System 4 Radio Control Installation and Operating Instructions System 4 P.O. Box 403, One Cedar Parkway, Jackson, WI 53037 Phone: 800-628-1909 Fax: 262-677-2058 Revision: April 19, 2012 Contents Introduction 3

More information

MODEL T-110 SERIES OPERATION MANUAL

MODEL T-110 SERIES OPERATION MANUAL Reno A & E Telephone: (775) 86-00 4655 Aircenter Circle Facsimile: (775) 86-9191 Reno, Nevada 8950 Internet: www.renoae.com USA e-mail: contact@renoae.com MODEL T-110 SERIES OPERATION MANUAL Single Channel

More information

ADI-100 Interrupter. Operator s Manual. 526 S. Seminole Bartlesville, OK /

ADI-100 Interrupter. Operator s Manual. 526 S. Seminole Bartlesville, OK / ADI-100 Interrupter Operator s Manual 526 S. Seminole Bartlesville, OK 74003 918/336-1221 www.sescocp.com ADI - 100 Interrupter FEATURES Clock Accuracy 100% during GPS lock Clock Drift 30 µsec per degree

More information

IMPORTANT! Please take the time to read through the manual before you start to install/program your equipment.

IMPORTANT! Please take the time to read through the manual before you start to install/program your equipment. PRODUCT DESCRIPTION IMPORTANT! Please take the time to read through the manual before you start to install/program your equipment. The systems KRC11, 12, 13 and 14 consists of two parts: the transmitter

More information

Wireless Expansion Module V1.0 Reference & Installation Manual

Wireless Expansion Module V1.0 Reference & Installation Manual Wireless Expansion Module V1.0 Reference & Installation Manual MG-RCV3 (DGP-848 / DGP-NE96) Table of Contents Introduction...1 Technical Specifications... 1 System Features... 2 Installation...2 Location...

More information

Product Manual QD1010-USB. Description. Contents. Material List. Setup. General Use. USB Cable Use. USB to RS485 Communications Converter

Product Manual QD1010-USB. Description. Contents. Material List. Setup. General Use. USB Cable Use. USB to RS485 Communications Converter Product Manual QD00-US US to Communications Converter Description The QD00-US is a US to converter used to allow asys Controls controllers to communicate with a PC. Material List QD00-US communication

More information

1 FUNCTIONAL DESCRIPTION WAY SPLITTER/INPUT BOARD FET RF AMPLIFIERS WAY POWER COMBINER VSWR CONTROL BOARD...

1 FUNCTIONAL DESCRIPTION WAY SPLITTER/INPUT BOARD FET RF AMPLIFIERS WAY POWER COMBINER VSWR CONTROL BOARD... CONTENTS 1 FUNCTIONAL DESCRIPTION...1 2 4-WAY SPLITTER/INPUT BOARD...2 3 FET RF AMPLIFIERS...3 4 4-WAY POWER COMBINER...4 5 VSWR CONTROL BOARD...5 6 ADJUSTMENT OF BIAS VOLTAGE TO ESTABLISH PROPER QUIESCENT

More information

Troubleshooting accelerometer installations

Troubleshooting accelerometer installations Troubleshooting accelerometer installations Accelerometer based monitoring systems can be tested to verify proper installation and operation. Testing ensures data integrity and can identify most commonly

More information

12 24 VAC/VDC ±10% (inhibited when voltage is applied) min. pulse width duration = 50 ms. Normal mode or Background Analysis mode

12 24 VAC/VDC ±10% (inhibited when voltage is applied) min. pulse width duration = 50 ms. Normal mode or Background Analysis mode DESCRIPTION SUPERSCAN-T Door-Mounted, Presence Sensor for Automatic, Pedestrian Doors SuperScan-T sensors are intended to be used with pedestrian, swing door systems. ENGLISH 1 1. Lens. Master circuit

More information

SA-505 Supervised Wireless Multi-Layer Repeater Installation Manual 1. General Description

SA-505 Supervised Wireless Multi-Layer Repeater Installation Manual 1. General Description SA-505 Supervised Wireless Multi-Layer Repeater Installation Manual 1. General Description The SA-505 is a sophisticated wireless learning and layering repeater for indoor use. It extends the range of

More information

OSMAC RDR Low-voltage Retrofit Kit

OSMAC RDR Low-voltage Retrofit Kit OSMAC RDR Low-voltage Retrofit Kit Part Number RDR0160LVN0 User s Guide Installation of the RDR (Radio Data Receiver) low-voltage unit will enable you to remotely operate your existing Vari-Time 4000 satellite

More information

Wireless Vehicle Sensor Installation Manual

Wireless Vehicle Sensor Installation Manual ACCESS CONTROLS WIRELESS ACCESS SYSTEMS Wireless Vehicle Sensor Installation Manual D A C Kit Includes: A. Transmitter Module/Cover B. Sensor/Sensor Cable C. Receiver (RB709U-NB required for some gate

More information

WRZ-RMT10K-0 Wireless Remote Temperature Transmitter

WRZ-RMT10K-0 Wireless Remote Temperature Transmitter WRZ-RMT10K-0 Wireless Remote Temperature Transmitter Product Bulletin WRZ-RMT10K-0, TE-6361A-1, TE-6361V-2, TE-636GV-2, TE-636S-1 The WRZ-RMT10K-0 Wireless Remote Temperature Transmitter is designed to

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL INSTALLATION & OPERATION MANUAL PREFACE This installation & operation manual is intended as an instruction manual for trained person who is in charge of installation, maintenance, repair, etc. Before installation

More information

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents KENCO ENGINEERING COMPANY P.O. BOX 470426, TULSA, OK 74147-0426 PHONE: (918) 663-4406 FAX: (918) 663-4480 http://www.kenco-eng.com e-mail: info@kenco-eng.com KENCO Loop Powered Magnetostrictive Transmitter

More information

INSTRUCTION MANUAL FOR DIODE FAULT DETECTOR

INSTRUCTION MANUAL FOR DIODE FAULT DETECTOR Publication Number: 351-02014-00 Publication Date: September 1990 Revised: March 1998 INSTRUCTION MANUAL FOR DIODE FAULT DETECTOR Part Number: 508-00118-40 508-00118-41 508-00118-42 508-00118-44 508-00118-45

More information

Addressing Electromagnetic Interference Issues with Phidgets

Addressing Electromagnetic Interference Issues with Phidgets Addressing Electromagnetic Interference Issues with Phidgets Phidgets are sensitive to electromagnetic interference (EMI) due to their extreme flexibility. Phidgets are used every day to build reliable

More information

Contents. Warranty and Disclaimer 2

Contents. Warranty and Disclaimer 2 Contents Warranty and Disclaimer 2 Physical Dimensions Board Layout 3 Usage Using the PWM board 4 Setting the start address 4 Dimming LED s 5,6 Typical hookup 7 Terminator 8 Troubleshooting Ground, termination,

More information

The Lutron Quick Reference Guide

The Lutron Quick Reference Guide Introduction How do I make my install and project a success? By looking at lessons learned from projects of all sizes, we have learned that a successful install comes down to a few key factors. In this

More information

MD12-2 Metal Loop Detector

MD12-2 Metal Loop Detector MD12-2 Metal Loop Detector Features Supply 12VDC Adjustable sensitivity (8 levels via dip switch) 2 x Relay outputs (each can be configured individually) Power up and loop activation LED indicator. Industry

More information

H7625B, H7626B, H7635B,C H7636B, H7655B, H7656B

H7625B, H7626B, H7635B,C H7636B, H7655B, H7656B H765B, H766B, H7635B,C H7636B, H7655B, H7656B DUCT-MOUNT AND OUTDOOR-MOUNT HUMIDITY/ TEMPERATURE SENSORS INSTALLATI INSTRUCTIS APPLICATI The H76XXB Duct-Mount and H76XXC Outdoor-Mount Humidity/Temperature

More information

Installation Instructions RF8010/RF8310 RF8010/RF8310: EXTERNAL ANTENNA

Installation Instructions RF8010/RF8310 RF8010/RF8310: EXTERNAL ANTENNA Installation Instructions RF8010/RF8310 HES, Inc. 22630 N. 17th Ave. Phoenix, AZ 85027 800-626-7590 1 Product Description Dimensions Orientation Compatibility Access Control Systems Proximity Cards Frequency

More information

Field Service Spares Procedure Replacement Coax Switch Kit, 8897B, 9497B, 14400B, ST88, ST94 & ST144

Field Service Spares Procedure Replacement Coax Switch Kit, 8897B, 9497B, 14400B, ST88, ST94 & ST144 1. Brief Summary: Troubleshooting document for diagnosing a fault with replacing the coax switch assembly on the 8897B, 9497B, 14400B, ST88, ST94 and ST144 antennas. 2. Checklist: Verify the Band of the

More information

LINKS1000CF INSTALLATION MANUAL Version 3.O

LINKS1000CF INSTALLATION MANUAL Version 3.O W A R N I N G Please refer to the System Installation Manual for information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. Security

More information

IMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

IMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION INSTALLATI INSTRUCTIS Models: RB-G-K10, RB-TX10 IMPORTANT: THIS DEVICE MUST BE PROFESSIALLY INSTALLED READ AND UNDERSTAND ALL INSTRUCTIS BEFORE BEGINNING INSTALLATI The Miller Edge RBand Monitored Gate

More information

Wireless Transceiver - Bell & Tone Scheduling Troubleshooting Guide

Wireless Transceiver - Bell & Tone Scheduling Troubleshooting Guide Primex XR 72MHz Synchronized Time Solution Wireless Transceiver - Bell & Tone Scheduling Troubleshooting Guide 2018 Primex. All Rights Reserved. The Primex logo is a registered trademark of Primex. All

More information

CAN BUS TROUBLESHOOTING

CAN BUS TROUBLESHOOTING 2003 BMW X5 4.4i (E53) V8-4398cc 4.4L DOHC (M62 TU) Vehicle > Powertrain Management > Computers and Control Systems > Information Bus > Testing and Inspection > Initial Inspection and Diagnostic Overview

More information

TS-WS-07 Wireless Indoor/Outdoor 8-Channel Thermo-Hygrometer with Jumbo Display User Manual

TS-WS-07 Wireless Indoor/Outdoor 8-Channel Thermo-Hygrometer with Jumbo Display User Manual TS-WS-07 Wireless Indoor/Outdoor 8-Channel Thermo-Hygrometer with Jumbo Display User Manual Table of Contents 1. Introduction......2 2.Getting Started.....2 2.1 Parts List.......2 2.2 Recommend Tools.........2

More information

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3 CHAPTER INSTALLATION 2 AND WIRING Contents of this Chapter... Ambient Conditions..............................2 2 Storage Conditions...............................2 2 Installation.....................................2

More information

LPB OMNI Broadcast Transmitter Installation Procedure Checklist

LPB OMNI Broadcast Transmitter Installation Procedure Checklist Installation Procedure LPB OMNI Broadcast Transmitter Installation Procedure Checklist LPB Communications, Inc. 960 Brook Road, Unit 5 Conshohocken, PA 19428 610-825-4100 phone 610-825-4047 fax www.lpbinc.com!

More information

Operating Instructions

Operating Instructions UltraDTEK Vehicle Loop Detector Operating Instructions PRODUCT OVERVIEW The UltraDTEK vehicle loop detector is plug-in compatible with Elite OmniControl TM board operators and other Elite A ELD enabled

More information

Webinar Organizers. Ryan Shea. Bruce McDuffee. Joe Ryan. Webinar Moderator. Applications Specialist. Product Manager. Precision Digital Corporation

Webinar Organizers. Ryan Shea. Bruce McDuffee. Joe Ryan. Webinar Moderator. Applications Specialist. Product Manager. Precision Digital Corporation Webinar Organizers Joe Ryan Product Manager Precision Digital Corporation Ryan Shea Applications Specialist Precision Digital Corporation Bruce McDuffee Webinar Moderator Precision Digital Corporation

More information