CET 5 Motor Protection Relay. Programming Menu Structure

Size: px
Start display at page:

Download "CET 5 Motor Protection Relay. Programming Menu Structure"

Transcription

1 CET 5 Motor Protection Relay Programming Menu Structure

2 Menu navigation keys Menu navigation keys Escape key. Returns to previous menu. Also required to be pressed after programming is completed to ensure setting changes are saved. Enter key. Selects underlined setting or stores entered value. SET/SHOW RELAY ESC RELAY Main Settings Move in the list OR Select underlined item in menu

3 Menu structure Main Menu > Meter Meter Instantaneous L 1 Current L 1 Angle L 2 Current L 2 Angle L 3 Current L 3 Angle GF Curr (Core B) GF -CB Angle GF Curr (Resid.) GF -RES Angle Average Current Motor Load Current Imbalance VAB VAB Angle VBC VBC Angle VCA VCA Angle Ave Line Voltage Imb. Real Power Reactive Power Apparent Powe r Power Factor Frequency Thermal Max Winding RTD Max Bearing RTD Ambient RTD Max Other RTD RTD 1 RTD 2 RTD 3 RTD 4 RTD 5 RTD 6 RTD 7 RTD 8 RTD 9 RTD 10 RTD 11 RTD 12 Motor Load Therm Cap Used RTD % TCU Used Thermal Trip In Time to Reset

4 Main Menu > Events Events Display Events Date Time Type Locked Rotor Torque L1 Current L2 Current L3 Current RES CB VAB VBC VCA VG Reset Events Main Menu > Motor Monitor Motor Monitor Motor Use Data Last Reset Date Last Reset Time Running Time Stopped Time Time Running Number of Starts Emergency Starts Reset Statistics Main Menu > Targets Targets ROW 1 ROW 2 ROW 3 ROW 4 ROW 5 ROW 6 ROW 7 ROW 7 ROW 8 ROW 9 ROW 10

5 Main Menu > Targets Row 1 Row 6 49T (Overload Trip) LOSSTRIP (Undercurrent Trip) JAMTRIP (Jam Trip) 49UBT (Current Imbalance Trip) 50P1T (Short Circuit Trip) RTDT (RTD (Winding/Bearing) Trip) PTCTRIP (PTC Trip) 50G1T (Ground Fault (Residual) Trip) VARA (VAR Warning) 37PA (Underpower Warning) 27P2T (Undervoltage Warning) 59P2T (Overvoltage Warning) SPDSAL (Speed Switch Warning) 81D1A (Frequency 1 Warning) 81D2A (Frequency 2 Warning) OTH ALRM (RTD (Other) Warning) Row 2 Row 7 VART (VAR Trip) 37PT (Underpower Trip) 27P1T (Undervoltage Trip) 59P1T (Overvoltage Trip) 47T (Phase Reversal Trip) 55T (Power Factor Trip) SPDSTR (Speed Switch Trip) 50N1T (Ground Fault (CB) Trip) VARA (VAR Warning) 37PA (Underpower Warning) 27P2T (Undervoltage Warning) 59P2T (Overvoltage Warning) SPDSAL (Speed Switch Warning) 81D1A (Frequency 1 Warning) 81D2A (Frequency 2 Warning) OTH ALRM (RTD (Other) Warning) Row 3 Row 8 SMTRIP (Start Time Trip) 81D1T (Frequency 1 Trip) 81D2T (Frequency 2 Trip) OTH TRIP (RTD (Other) Trip) AMBTRIP (RTD (Ambient) Trip) PTCFLT (PTC Error Trip) RTDFLT (RTD Error Trip) MCMFLT (MCM Error Trip) STOPPED (Stopped State) RUNNING (Running State) STARTING (Starting State) STAR (Star (Wye) Starting State) DELTA (Delta Starting State) START (Start Command) Row 4 Row 9 COMMIDLE (Comm Idle Trip) COMMLOSS (Comm Loss Trip) REMTRIP (Remote Trip) COMMFLT (Comm Fault Trip) IN1 (Input 1 State) IN2 (Input 2 State) IN3 (Input 3 State) IN4 (Input 4 State) IN5 (Input 5 State) Row 5 Row 10 49A (Overload Warning) LOSSALRM (Undercurrent Warning) JAMALRM (Jam Warning) 46UBA (Current Imbalance Warning) RTDA (RTD (Wdg/Bearing) Warning) 55A (Power Factor Warning) 50N2T (Ground Fault (CB) Warning) 50G2T (Ground Fault (CB) Warning) TRIP (Trip Relay State) AUX 1 (Auxiliary Relay 1 State) AUX 2 (Auxiliary Relay 2 State) AUX 3 (Auxiliary Relay 3 State) AUX 4 (Auxiliary Relay 4 State) AUX 5 (Auxiliary Relay 5 State) AUX 6 (Auxiliary Relay 6 State) Main Menu > Set/Show

6 Set/Show RELAY Main Settings PORT Overload Set PORT F Short Ckt Set IO ASSIGN SPEED GF-CB Settings TRIP RELAY ASSIGN DATA BITS GF-Res Settings AUX1 ASSIGN PARITY Jam Settings AUX2 ASSIGN STOP BITS Undercurrent Set AUX3 ASSIGN PORT TIMEOUT Current Imb Set AUX4 ASSIGN HDWR HAND SHAKING Prot. Disable IN1 ASSIGN Start Monitoring IN2 ASSIGN PORT 4 Star-Delta Set COMM INTERFACE Start Inhibt Set DATE/TIME PROTOCOL Speed Sw Set DATE SPEED PTC Setting TIME PARITY RTD Setting MODBUS SLAVE ID Undervoltage Set PASSWORD Overvoltage Set New PW VAR Settings Underpower Set Power Factor Set Freq Settings Phase Rev Set Load Control Set I/O Settings Trip Inhibit Relay Behavior Timer Settings Front Panel Set Display Set

7 Main Menu > Set/Show > Relay Main Settings GF-Res Settings RTD Settings UNIT ID LINE 1 GF-RES TRIP LEVL RTD ENABLE UNIT ID LINE 2 GF-RES TRIP DLAY RTD RESET MODE PHASE ROTATION GF-RES WARN LEVL RTD1 LOCATION RATED FREQ. GF-RES WARN DLAY RTD1 TYPE DATE FORMAT Jam Settings RTD1 TRIP LEVEL PHASE CT RATIO JAM TRIP LEVEL RTD1 WARN LEVEL MOTOR FLA JAM TRIP DELAY RTD2 LOCATION TWO SPEED ENABLE JAM WARN LEVEL RTD2 TYPE CT RATIO-2 nd JAM WARN DELAY RTD2 TRIP LEVEL MOTOR FLA-2 nd Undercurrent Set RTD2 WARN LEVEL CORE B. CT RATIO UC TRIP LEVEL RTD3 LOCATION PHASE VT RATIO UC TRIP DELAY RTD3 TYPE LINE VOLTAGE UC WARN LEVEL RTD3 TRIP LEVEL XFMER CONNECTION UC WARN DELAY RTD3 WARN LEVEL Overload Set UC START INHIBIT RTD4 LOCATION OVERLOAD ENABLE Current Imb Set RTD4 TYPE OL RESET MODE CI TRIP LEVEL RTD4 TRIP LEVEL OL RESET LEVEL CI TRIP DELAY RTD4 WARN LEVEL SERVICE FACTOR CI WARN DELAY RTD5 LOCATION MOTOR LRC CI WARN DELAY RTD5 TYPE LOCKD ROTOR TIME Prot. Disable RTD5 TRIP LEVEL ACCEL FACTOR PROT INHIBT TIME RTD5 WARN LEVEL RUN STATE TIME K OL INHIBT TIME RTD6 LOCATION MOTOR LRC-2 nd Start Monitoring RTD6 TYPE MOTOR LRT-2 nd START MOTOR TIME RTD6 TRIP LEVEL ACCEL FACT-2 nd Start-Delta Set RTD6 WARN LEVEL RUN ST TC-2 nd STAR-DELTA ENABL RTD7 LOCATION OL WARN LEVEL MAX STAR TIME RTD7 TYPE START INH. LEVEL Start Inhibt RTD7 TRIP LEVEL STOP COOL TIME STARTS/HR. RTD7 WARN LEVEL OL RTD BIASING? MIN. OFF TIME RTD8 LOCATION Short Ckt Set RESTART BLK TIME RTD8 TYPE SC TRIP LEVEL Speed Sw Set RTD8 TRIP LEVEL SC TRIP DELAY SS TRIP DELAY RTD8 WARN LEVEL SC WARN LEVEL SS WARN DELAY RTD9 LOCATION SC WARN LEVEL PTC Setting RTD9 TYPE GF-CB Setting PTC ENABLE RTD9 TRIP LEVEL GF-CB TRIP LEVEL PTC RESET MODE RTD9 WARN LEVEL GF-CB TRIP DELAY RTD10 LOCATION GF-CB WARN LEVEL GF-CB WARN DELAY RTD10 TYPE RTD10 TRIP LEVEL RTD10 WARN LEVEL RTD11 LOCATION RTD11 TYPE RTD11 TRIP LEVEL RTD11 WARN LEVEL RTD12 LOCATION RTD12 TYPE RTD12 TRIP LEVEL RTD12 WARN LEVEL WIND TRIP VOTING BEAR TRIP VOTING TMP RTD BIASING?

8 Main Menu > Set/Show > Relay Cont d Undervoltage Set UV TRIP LEVEL UV TRIP DELAY UV WARN LEVEL UV WARN DELAY Overvoltage Set OV TRIP LEVEL OV TRIP DELAY OV WARN LEVEL OV WARN DELAY VAR Setting NEG VAR TRIP POS VAR TRIP VAR TRIP DELAY NEG VAR WARN LEV POS VAR WARN LEV VAR WARN DELAY Underpower Set UP TRIP LEVEL UP TRIP DELAY UP WARN LEVEL TRIP UP WARN DELAY Power Factor Set PF LAG TRIP LEVEL PF LD TRIP LEVEL PF TRIP DELAY PF LAG WARN LEVEL PF LD WARN LEVEL PF WARN DELAY Freq Settings FREQ1 TRIP LEVEL FREQ1 TRIP DELAY FREQ1 WARN LEVEL FREQ1 WARN DELAY FREQ2 TRIP LEVEL FREQ2 TRIP DELAY FREQ2 WARN LEVEL FREQ2 WARN DELAY Phase Rev Set PH REV. ENABLE Load Control Set LOAD CONTROL SEL LD CTL CUR UPPER LD CTL CUR LOWER LD CTL PWR UPPER LD CTL PWR LOWER LD CTL TCU UPPER LC CTL TCU LOWER I/O Settings ANALOG OG OUT SEL Trip Inhibit CURRENT INBALANC JAM GROUND FAULT SHORT CIRCUIT UNDERCURRENT START INHIBIT PTC RTD Relay Behavior FAIL-SAFE AUX1 FAIL-SAFE AUX2 FAIL-SAFE AUX3 FAIL-SAFE AUX4 FAIL-SAFE AUX5 FAIL-SAFE AUX6 FAIL-SAFE Timer Settings ON DELAY T1 OFF DELAY T1 ON DELAY T2 OFF DELAY T2 Front Panel Set LCD TIMEOUT LCD CONTRAST Display Set TIME & DATE GROUND CURRENT CURRENT IMBALANC FREQUENCY THERM CAP USED VOLTAGE IMBALANC POWER RTD TEMPERATURE

9 Main Menu > Status Status FID CID Identity Code L1 L2 L3 RES CB VA VB VC PS_Vdc FPGA GPSB HMI RAM ROM CR_RAM Non_Vol Clk_Bat Clock PTC RTD MCM/CWE Voltage I/O_Crd Com_Crd MAC_ID ASA DN_Rate DN_Status Relay Enabled Definition Firmware identifier string Firmware checksum identifier Relay configuration identification DC offset in hardware circuits of current channels DC offset in hardware circuits of voltage channels Power supply status FPGA programming unsuccessful, or FPGA failed General Purpose Serial Bus Front-Panel FGPA programming unsuccessful, or Front-Panel FPGA failed Volatile memory integrity Firmware integrity Integrity of settings in RAM and code that runs in RAM Integrity of data stored in nonvolatile memory Clock battery integrity Clock functionality Integrity of PTC Integrity of RTD module/communications Integrity of current board and MCM/CWE Integrity of voltage board Integrity of I/O card Integrity of DeviceNet card and network DeviceNet card specific card identification Manufacturer identifier for DevieNet DeviceNet card network communications data speed DeviceNet connection and fault status

NO WARRANTIES OF ANY KIND ARE IMPLIED ON THE INFORMATION CONTAINED IN THIS DOCUMENT.

NO WARRANTIES OF ANY KIND ARE IMPLIED ON THE INFORMATION CONTAINED IN THIS DOCUMENT. MODBUS/BECO2200-M3425A Communication Data Base for M-3425A Integrated Protection System Device I.D. = 150 Specifications presented herein are thought to be accurate at the time of publication but are subject

More information

ES-777-MV-P2_A1 03/01/10

ES-777-MV-P2_A1 03/01/10 ENGINEERING SPECIFICATION SYMCOM MODEL 777-MV-P2 Electronic Overload Relay PART 1 GENERAL 1.1 REFERENCES A. UL 508 Industrial Control Equipment Underwriters Laboratories B. IEC 60947 Low Voltage Switchgear

More information

GS1 Parameter Summary Detailed Parameter Listings...4 9

GS1 Parameter Summary Detailed Parameter Listings...4 9 CHAPTER AC DRIVE 4 PARAMETERS Contents of this Chapter... GS1 Parameter Summary...............................4 2 Detailed Parameter Listings..............................4 9 Motor Parameters.........................................4

More information

NTG MULTIFUNCTON GENERATOR PROTECTION RELAY. NTG-Slide

NTG MULTIFUNCTON GENERATOR PROTECTION RELAY. NTG-Slide NTG MULTIFUNCTON GENERATOR PROTECTION RELAY 1 NTG Digital protection relay that integrates a number of functions required r for the protection of generators. It is used in power stations from gas, steam,

More information

PARAMETER LIST MICROFUSION

PARAMETER LIST MICROFUSION MICROFUSION PARAMETER LIST MicroFUSION controllers contain nonvolatile EEPROMs, and writing too frequently to an individual parameter may wear out the EEPROM and cause the controller to fail. Control Concepts

More information

CHAPTER AC DRIVE PARAMETERS. In This Chapter...

CHAPTER AC DRIVE PARAMETERS. In This Chapter... CHAPTER AC DRIVE 4 PARAMETERS In This Chapter... GS2 Parameter Summary....................4 2 Detailed Parameter Listings.................4 11 Motor Parameters........................4 11 Ramp Parameters.........................4

More information

TOSVERT TM VF-nC3 Parameter List

TOSVERT TM VF-nC3 Parameter List TOSVERT TM VF-nC Parameter List E658664 - Setting information * Please fill it in if necessary. Item Content Item Content Setting date / person Customer Application Application model Motor manufacturer

More information

BACnet- MS/TP COMMUNICATION V

BACnet- MS/TP COMMUNICATION V - MS/TP COMMUNICATION V1.00.08.17 11.1 Introduction The VFD can be controlled and monitored through the BACnet MS/TP protocol over an RS-485 connection. The VFD operates as an MS/TP master device, which

More information

CHAPTER 8 SUMMARY OF PARAMETER SETTINGS

CHAPTER 8 SUMMARY OF PARAMETER SETTINGS CHAPTER 8 SUMMARY OF PARAMETER SETTINGS VFD-S Series!: The parameter can be set during operation, *: Twice the value for 460V class. Group 0 User Parameters Parameters Explanation s 0-00 Identity Code

More information

See notes for calculations 4110 Usage Hours 1 Integer RO Y - Hours YP Usage Minutes 1 Integer RO Y - Minutes 0-59 YP

See notes for calculations 4110 Usage Hours 1 Integer RO Y - Hours YP Usage Minutes 1 Integer RO Y - Minutes 0-59 YP Table of Contents 2 FW Release summary Y Y Y Y Y Y PM RS FW History Y Y Y PM_2 OS FW History Y Y Y PM_2 RS FW History Y Y Y Setup & Status Metering Min Max Demand IO Alarms N N Reset Commands DL System

More information

MOTOR MANAGER RELAY INSTRUCTION MANUAL. Copyright 1993 Multilin All Rights Reserved. The 301 is CSA approved. 215 Anderson Avenue 9746 Whithorn Dr.

MOTOR MANAGER RELAY INSTRUCTION MANUAL. Copyright 1993 Multilin All Rights Reserved. The 301 is CSA approved. 215 Anderson Avenue 9746 Whithorn Dr. 301 MOTOR MANAGER RELAY INSTRUCTION MANUAL Software Rev: 301.D1.20 Manual P/N: 1601-0014-D4 Copyright 1993 Multilin All Rights Reserved The 301 is CSA approved. CANADA USA Multilin Multilin Division of

More information

Replacement solution

Replacement solution Replacement solution for the ABB DPU2000R protection and control relay Specification File, Revision, Date (Pages) Replacement Relay Specification_ABB DPU2000R_0.doc, Revision 0, August 2, 2013 (37) Table

More information

Manual. Application Inverter MOVIDRIVE modular/system with CiA402 Device Profile Parameter Description * _0718*

Manual. Application Inverter MOVIDRIVE modular/system with CiA402 Device Profile Parameter Description * _0718* Drive Technology \ Drive Automation \ System Integration \ Services *25835130_0718* Manual Application Inverter MOVIDRIVE modular/system with CiA402 Device Profile Parameter Description Edition 07/2018

More information

RM-2000-RTDW Remote Monitor User s Guide

RM-2000-RTDW Remote Monitor User s Guide RM-2000-RTDW Remote Monitor User s Guide The RM-2000-RTDW motor-monitoring device can be used to monitor and/or control SymCom s Model 777 via an RS-485 Modbus network. Two form C output relays are available

More information

INTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]

INTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM] Feature Suit for LV/ HV voltage system Compact design with all real-time measurement Consist of basic unit and optional modules 10 years back-up of integrated energy data Large LCD, high brightness High

More information

Motor Protection. May 31, Tom Ernst GE Grid Solutions

Motor Protection. May 31, Tom Ernst GE Grid Solutions Motor Protection May 31, 2017 Tom Ernst GE Grid Solutions Motor Relay Zone of Protection -Electrical Faults -Abnormal Conditions -Thermal Overloads -Mechanical Failure 2 Setting of the motor protection

More information

Power connections, minimum and maximum wiring capabilities, tightening torque

Power connections, minimum and maximum wiring capabilities, tightening torque Wiring - power terminals Power Observe the cable cross-sectional areas recommended in the standards. The soft starter must be grounded to conform to the regulations concerning leakage currents. If the

More information

Variable Frequency Drive / Inverter (0.4 ~ 280kW)

Variable Frequency Drive / Inverter (0.4 ~ 280kW) Variable Frequency Drive / Inverter (0.4 ~ 280kW) & Standard Features Configuration Comparison Comparison Table Enclosure IP00 IP20 NEMA 1 Rating Single phase 0.4 2.2kW 0.4 1.5kW Three phase 0.4 4kW Constant

More information

Fan and Pump AC Inverter

Fan and Pump AC Inverter Fan and Pump AC Inverter Key Features for Fan and Pump Applications PID and Auto Energy Saving Functions. Input Phase Loss and Output Phase Loss Protection. LCD Keypad can be used to copy parameter settings

More information

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection Quick Start Guide TECO F510 Inverter This guide is to assist you in installing and running the inverter and verify that it is functioning correctly for it s main and basic features. For detailed information

More information

MPS6 MOTOR PROTECTION SYSTEM

MPS6 MOTOR PROTECTION SYSTEM Version: September 18, 2007 MPS6 MOTOR PROTECTION SYSTEM CHANGES FROM MPR6/MPC6 TO MPS6 1. Six programmable discrete (digital) inputs to the MPS6. 2. Six Programmable Output Relays. 3. One programmable

More information

P-SERIES VFD 1-40HP (200~230VAC), 1-400HP (380~480VAC),3Ø Dual Rated for Constant & Variable Torque Integrated PID Control

P-SERIES VFD 1-40HP (200~230VAC), 1-400HP (380~480VAC),3Ø Dual Rated for Constant & Variable Torque Integrated PID Control P-SERIES VFD 1-40HP (200~230VAC), 1-400HP (380~480VAC),3Ø Dual Rated for Constant & Variable Torque Integrated PID Control NEW FIRMWARE MAKES SETUP A SNAP Application based commissioning allows parameters

More information

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual INDEX A AC Drive Cover: 1 6 Dimensions: 2 4 External Parts and Labels: 1 6 Heat Sink Fins: 1 6 Input Mode Switch (Sink/Source): 1 6 Introduction to DuraPulse GS3 AC drive: 1 3 Keypad: 1 6 Model Number

More information

PumpSmart Commissioning Process

PumpSmart Commissioning Process PumpSmart Commissioning Process 1. Complete the PumpSmart Warranty Registration form. The warrantee registration is our method for determining if an installation has been commissioned properly and to identify

More information

GB QUICK GUIDE FOR THE CONFIGURATION OF VARIABLE SPEED DRIVES

GB QUICK GUIDE FOR THE CONFIGURATION OF VARIABLE SPEED DRIVES GB QUICK GUIDE FOR THE CONFIGURATION OF VARIABLE SPEED DRIVES LOVATO ELECTRIC S.P.A. 24020 GORLE (BERGAMO) ITALIA VIA DON E. MAZZA, 12 TEL. 035 4282111 FAX (Nazionale): 035 4282200 FAX (International):

More information

CHAPTER 8 PARAMETER SUMMARY

CHAPTER 8 PARAMETER SUMMARY CHAPTER PARAMETER SUMMARY Group 0: System Parameter VFD-V Series 00-00 Identity Code Based on the model type 00-01 Rated Current Display 00-02 Parameter Reset 00-03 00-04 Star-up Display of the Drive Definitions

More information

NX Series Inverters. HVAC Pocket Programming Guide

NX Series Inverters. HVAC Pocket Programming Guide NX Series Inverters HVAC Pocket Programming Guide HVAC Pocket Programming Guide HVAC Pocket Programming Guide / Contents This guide provides a single reference document for the user of NXL HVAC (product

More information

MPS PROFIBUS-DP INTERFACE

MPS PROFIBUS-DP INTERFACE 3714 Kinnear Place Saskatoon, SK Canada S7P 0A6 Ph: (306) 373-5505 Fx: (306) 374-2245 www.littelfuse.com/protectionrelays MPS PROFIBUS-DP INTERFACE PRELIMINARY SEPTEMBER 8, 2003 Publication: PROFIBUS-M

More information

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps. VFD - D700 Series Specifications The latest low-cost variable speed control solution for centrifugal pumps. Built-in PID Control to maintain pressure, flow, measured value, and much more 125% overload

More information

General-Purpose AC Servo. MELSERVO-J4 Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

General-Purpose AC Servo. MELSERVO-J4 Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING) General-Purpose AC Servo MELSERVO-J4 Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING) N Safety Instructions Please read the instructions carefully before using the equipment. To use the equipment

More information

SEL-710 Motor Protection Relay

SEL-710 Motor Protection Relay SEL-710 Motor Protection Relay Motor Protection Relay Major Features and Benefits The SEL-710 Motor Protection Relay provides an exceptional combination of protection, monitoring, control, and communication

More information

Contents. Introduction and description Package contents Device identification PM Options... 80

Contents. Introduction and description Package contents Device identification PM Options... 80 Contents 1 Introduction and description Package contents... 77 Device identification... 77 2 Characteristics PM500... 78 Options... 80 3 Installation Front-panel cut-out... 82 Mounting... 82 4 Connections

More information

Addendum SmartPAC Third Party Communications Firmware

Addendum SmartPAC Third Party Communications Firmware Addendum SmartPAC Third Party Communications Firmware The SmartPAC Third Party Communications Firmware option enables SmartPAC 2 and the original SmartPAC to transmit real-time and status information to

More information

MM2 STOP. MOTOR MANAGER 2 Instruction Manual. GE Industrial Systems

MM2 STOP. MOTOR MANAGER 2 Instruction Manual. GE Industrial Systems g GE Industrial Systems MM2 MOTOR MANAGER 2 Instruction Manual MM2 Firmware Revision: 5.2x MM2 Software Revision: 5.2x or newer Manual P/N: 1601-0056-DS (GEK-106294D) Copyright 2007 GE Multilin RUNNING

More information

General Specifications FECA-TE /2010. Phone: Fax: Web:

General Specifications FECA-TE /2010. Phone: Fax: Web: General Specifications FECA-TE-117 06/2010 1. Standard Specifications 1) Three-phase 230V series Output ratings Input ratings Braking Item Specifications Type (FRN C1S-2U) F12 F25 F50 001 002 003 005 Nominal

More information

PARAMETER LIST PARAMETER LIST

PARAMETER LIST PARAMETER LIST PRMETER LIST PRMETER LIST dvanced Genset Controller, GC 200 larm list Parameter list Document no.: 489340605L SW version 4.2.x or later GC 200 parameter list 489340605 UK Contents: General information...

More information

Hitachi P1 Closed Loop Hoist Basic Instruc on Manual

Hitachi P1 Closed Loop Hoist Basic Instruc on Manual Hitachi P1 Closed Loop Hoist Basic Instruc on Manual DH Firmware V.18 DETROIT HOIST AND CRANE LLC, CO. 6650 STERLING DRIVE NORTH STERLING HEIGHTS MICHIGAN 48312 Introduction This manual only applies to

More information

ROLL TO ROLL FUNCTION MANUAL FR-A (0.4K)-04750(90K)-R2R FR-A (0.4K)-06830(280K)-R2R FR-A (315K)-12120(500K)-R2R

ROLL TO ROLL FUNCTION MANUAL FR-A (0.4K)-04750(90K)-R2R FR-A (0.4K)-06830(280K)-R2R FR-A (315K)-12120(500K)-R2R INVERTER ROLL TO ROLL FUNCTION MANUAL FR-A820-00046(0.4K)-04750(90K)-R2R FR-A840-00023(0.4K)-06830(280K)-R2R FR-A842-07700(315K)-12120(500K)-R2R Roll to Roll Function The FR-A800-R2R inverter has dedicated

More information

DEIF A/S. Description of options. Option H3 Serial communication Profibus DP Multi-line 2 version 2. Description of option. Functional description

DEIF A/S. Description of options. Option H3 Serial communication Profibus DP Multi-line 2 version 2. Description of option. Functional description Description of options Option H3 Serial communication Profibus DP Multi-line 2 version 2 4189340279I SW 2.42.X Description of option Functional description DEIF A/S Parameter table Data tables DEIF A/S,

More information

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter SDM630MCT-RJV-333mV SDM630MCT-RJA-00mA Three phase multifunction din rail energy meter Plug-in solution; labor saving; wiring mistake free Measures kwh KVarh, KW, Kvar, KVA, P, F, PF, Hz, dmd, V, A, THD,etc.

More information

In the event of a failure, the inverter switches off and a fault code appears on the display.

In the event of a failure, the inverter switches off and a fault code appears on the display. Issue 03/05 Faults and Alarms 5 Faults and Alarms 5.1 Fault messages In the event of a failure, the inverter switches off and a fault code appears on the display. NOTE To reset the fault code, one of three

More information

vacon nx all in one application manual ac drives Phone: Fax: Web: -

vacon nx all in one application manual ac drives Phone: Fax: Web:  - vacon nx ac drives all in one application manual vacon 1 INDEX Document ID:DPD00903A Revision release date: 30.3.2012 1. Basic Application...5 1.1. Introduction...5 1.1.1. Motor protection functions in

More information

HITACHI. L100-M Series Inverter Quick Reference Guide. Hitachi Industrial Equipment Systems Co., Ltd. Single-phase Input 100V Class

HITACHI. L100-M Series Inverter Quick Reference Guide. Hitachi Industrial Equipment Systems Co., Ltd. Single-phase Input 100V Class HITACHI L1-M Series Inverter Quick Reference Guide Single-phase Input 1V Class Hitachi Industrial Equipment Systems Co., Ltd. Manual No. NB5741XD December 23 Caution: Be sure to read the L1 Inverter Manual

More information

M20E MOTOR PROTECTION RELAY

M20E MOTOR PROTECTION RELAY M20E MOTOR PROTECTION RELAY TECHNICAL REFERENCE GUIDE VOLUME 2.2 F I G U R E 1 M 2 0 E M O T O R P R O T E C T I O N R E L AY 1 M20E TECHNICAL REFERENCE MANUAL VOLUME 2.2 1. Contents 1. Contents 2 2. Introduction

More information

ELECTRICAL VARIABLE ANALYZER RELAY EVAR

ELECTRICAL VARIABLE ANALYZER RELAY EVAR ELECTRICAL VARIABLE ANALYZER RELAY EVAR 1 ORION ITALIA SERIES MODBUS PROTOCOL. The ORION ITALIA SERIES implement a subset of the AEG Modicon Modbus serial communication standard. Many devices support this

More information

Softstarters. Specification guide. Type PST. Low Voltage Products & Systems

Softstarters. Specification guide. Type PST. Low Voltage Products & Systems Softstarters Type PST Low Voltage Products & Systems 2 Low Voltage Products & Systems 1SXU132171M0201 [AC 1006.8] - 5/03 ABB Inc. 888-385-1221 www.abb.com/lowvoltage Softstarters Type PST Specification

More information

General-Purpose AC Servo. MELSERVO-J4 Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

General-Purpose AC Servo. MELSERVO-J4 Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING) General-Purpose AC Servo MELSERVO-J4 Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING) K Safety Instructions Please read the instructions carefully before using the equipment. To use the equipment

More information

AV-300i Specifications. Saftronics Inc. VG10 Product Specifications VG10. Dynamic Vector Drive

AV-300i Specifications. Saftronics Inc.   VG10 Product Specifications VG10. Dynamic Vector Drive Saftronics Inc. www.saftronics.com TM AV-300i Specifications VG10 Product Specifications VG10 Dynamic Vector Drive 1 Category Item Description Nominal Motor 230 VAC, 3 Phase 1/4 Hp to 125 Hp 460 VAC, 3

More information

Temperature Controller model MFC-301/T-Dry. Version for Dry Transformers and Motors. Technical Manual. Licht

Temperature Controller model MFC-301/T-Dry. Version for Dry Transformers and Motors. Technical Manual. Licht Temperature Controller model MFC-301/T-Dry Version for Dry Transformers and Motors Technical Manual Licht Contents 1 Introduction 2 2 Operating principle 3 2.1 General principle 3 2.2 RTD operation 3 3

More information

MiCOM P220/P225 COMMUNICATION

MiCOM P220/P225 COMMUNICATION P22x/EN CT/B44 COMMUNICATION P22x/EN CT/B44 P22x/EN CT/B44 Page 1/56 CONTENT 1. MODBUS PROTOCOL 3 1.1 MODBUS communication characteristics 3 1.1.1 MODBUS network characteristics 3 1.1.2 Parameters of the

More information

KW/HP-P2 INSTALLATION INSTRUCTIONS POWER MONITOR. Revision A1 Rapid City, SD, USA, 01/2010 II_777-KW-HP-P2_A1

KW/HP-P2 INSTALLATION INSTRUCTIONS POWER MONITOR. Revision A1 Rapid City, SD, USA, 01/2010 II_777-KW-HP-P2_A1 INSTALLATION INSTRUCTIONS Revision A1 Rapid City, SD, USA, 01/2010 MODEL POWER MONITOR 777-KW/HP-P2 777-575-KW/HP-P2 II_777-KW-HP-P2_A1 2880 North Plaza Drive, Rapid City, South Dakota 57702 (800) 843-8848

More information

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. Important User Information DeviceNet Module Instructions Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. It

More information

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING) General-Purpose AC Servo MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING) F Safety Instructions Please read the instructions carefully before using the equipment. To use the equipment

More information

ABB machinery drives. Supplement to Users Manual ACS355 Low ambient start (+N828)

ABB machinery drives. Supplement to Users Manual ACS355 Low ambient start (+N828) ABB machinery drives Supplement to Users Manual ACS355 Low ambient start (+N828) List of related manuals Drive manuals and guides ACS355 user s manual ACS355 drives with IP66/67 / UL Type 4x enclosure

More information

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS INSTRUCTIONS MANUAL IM831-U v0.92 HRI-R40W sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS INDEX: GENERAL TYPES ACESSORIES AND OPTIONS

More information

Numerical Multi-Function Motor Protection Relay RHO 3. Operation & Maintenance Instruction Manual

Numerical Multi-Function Motor Protection Relay RHO 3. Operation & Maintenance Instruction Manual Numerical Multi-Function Motor Protection Relay RHO 3 Operation & Maintenance Instruction Manual RHO MANUAL Contents Section Page Description of operation 4 2 Performance specification 20 3 Relay settings

More information

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment T/3000 Substation Maintenance and Commissioning Test Equipment MULTI FUNCTION SYSTEM FOR TESTING SUBSTATION EQUIPMENT SUCH AS: CURRENT, VOLTAGE AND POWER TRANSFORMERS, ALL TYPE OF PROTECTION RELAYS, ENERGY

More information

SEL Motor Protection Relay

SEL Motor Protection Relay SEL-710-5 Motor Protection Relay Synchronous Motor Control and Protection, Broken Rotor Bar Detection, and Arc-Flash Detection Major Features and Benefits The SEL-710-5 Motor Protection Relay provides

More information

APPLICATION: The heart of the system is a DSR 100 Digital Static Regulator used in conjunction with standard SCR based rectifier bridges.

APPLICATION: The heart of the system is a DSR 100 Digital Static Regulator used in conjunction with standard SCR based rectifier bridges. APPLICATION: Basler Electric offers a New Line of digitally controlled brush (static) or brushless excitation systems designed for use with existing Hydro, Gas as well as Diesel driven generators requiring

More information

mmint Modbus translator module installation and use

mmint Modbus translator module installation and use Instructional Leaflet IL66A7508H09 Supersedes July 2009 mmint Modbus translator module installation and use Contents Description Page List of figures... 2 List of tables.... 2 Section 1: General description...

More information

www. ElectricalPartManuals. com Transformer Differential Relay MD32T Transformer Differential Relay

www. ElectricalPartManuals. com Transformer Differential Relay MD32T Transformer Differential Relay Transformer Differential Relay The MD3T Transformer Differential Relay is a member of Cooper Power Systems Edison line of microprocessor based protective relays. The MD3T relay offers the following functions:

More information

ELECRTIC MOTORS UNIVERSAL PROTECTION DEVICE UBZ-302 OPERATING MANUAL

ELECRTIC MOTORS UNIVERSAL PROTECTION DEVICE UBZ-302 OPERATING MANUAL LTD Intellectual Industrial Electronics ELECRTIC MOTORS UNIVERSAL PROTECTION DEVICE OPERATING MANUAL Review the Operating manual before using the unit. Store the unit in the operating environment for 2

More information

General-Purpose AC Servo. Servo Amplifier Instruction Manual (Troubleshooting)

General-Purpose AC Servo. Servo Amplifier Instruction Manual (Troubleshooting) General-Purpose AC Servo Servo Amplifier Instruction Manual (Troubleshooting) SAFETY PRECAUTIONS (Please read the instructions carefully before using the equipment.) To use the equipment correctly, do

More information

NX series Constant and variable torque Variable Speed Drives for induction motors

NX series Constant and variable torque Variable Speed Drives for induction motors Honeywell All in One Application Manual NX series Constant and variable torque Variable Speed Drives for induction motors Subject to changes without notice CONTENTS NX "All in One" APPLICATION MANUAL INDEX

More information

SJ100 Series Inverter Quick Reference Guide. Single-phase Input 200V Class Three-phase Input 200V Class Three-phase Input 400V Class

SJ100 Series Inverter Quick Reference Guide. Single-phase Input 200V Class Three-phase Input 200V Class Three-phase Input 400V Class HITACHI SJ1 Series Inverter Quick Reference Guide Single-phase Input 2V Class Three-phase Input 2V Class Three-phase Input 4V Class Hitachi Industrial Equipment Systems Co., Ltd. Manual No. NB5821XD Dec.

More information

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING) General-Purpose AC Servo MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING) B Safety Instructions Please read the instructions carefully before using the equipment. To use the equipment

More information

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING) General-Purpose AC Servo MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING) B Safety Instructions Please read the instructions carefully before using the equipment. To use the equipment

More information

INTERNATIONAL SERVICE BULLETIN - I #2-319 Liberty - Delta M+ VFD parameter list. A VFD parameter list is required when replacing a DELTA M+ VFD.

INTERNATIONAL SERVICE BULLETIN - I #2-319 Liberty - Delta M+ VFD parameter list. A VFD parameter list is required when replacing a DELTA M+ VFD. RYKO Manufacturing Company 116 N.W. 54th Ave. P.O.Box 38 Grimes, Iowa 5111 Phone (515) 986-37 www.ryko.com Fax (515) 986-3621 sales@ ryko.com INTERNATIONAL SERVICE BULLETIN - I #2-319 Liberty - Delta M+

More information

MM200 Motor Management System

MM200 Motor Management System Digital Energy Multilin MM200 Motor Management System Low voltage motor protection and control QuickStart Guide MM200 revision: 1.2x Manual P/N: 1601-9030-A6 GE publication code: GEK-113401E Copyright

More information

DEIF A/S. Description of options. Option H1 Serial communication CAN open. Description of options. Functional description. Tables.

DEIF A/S. Description of options. Option H1 Serial communication CAN open. Description of options. Functional description. Tables. Description of options Option H1 Serial communication CAN open 4189340277G SW version 2.42.X Description of options Functional description DEIF A/S Tables Parameter list Object dictionary DEIF A/S, Frisenborgvej

More information

AV-300i Specifications. GE Industrial Systems. Product Specifications. A New Concept in Automation. AV-300i

AV-300i Specifications. GE Industrial Systems. Product Specifications. A New Concept in Automation. AV-300i GE Industrial Systems Product Specifications AV-300i A New Concept in Automation. TM 1 General Item Description Nominal Motor 230V, 3 Phase 15 Hp to 100 Hp 460V, 3 Phase 3/4 Hp to 200 Hp Enclosure, Standard

More information

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING) General-Purpose AC Servo MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING) D Safety Instructions Please read the instructions carefully before using the equipment. To use the equipment

More information

Power systems Protection course

Power systems Protection course Al-Balqa Applied University Power systems Protection course Department of Electrical Energy Engineering 1 Part 5 Relays 2 3 Relay Is a device which receive a signal from the power system thought CT and

More information

g GE POWER MANAGEMENT

g GE POWER MANAGEMENT 469 FREQUENTLY ASKED QUESTIONS 1 Can not communicate through the front port RS232 Check the following settings Communication port on your computer ( com1, com2 com3 etc ) Parity settings must match between

More information

Option H2, Modbus communication Automatic Gen-set Controller H SW version 2.33.X

Option H2, Modbus communication Automatic Gen-set Controller H SW version 2.33.X Description of options Option H2, Modbus communication Automatic Gen-set Controller 4189340356H SW version 2.33.X Description of option Parameter list DEIF A/S Data tables Parameter table DEIF A/S, Frisenborgvej

More information

PROTECTION SySTEM Integrated protection and control for medium sized AC motors

PROTECTION SySTEM Integrated protection and control for medium sized AC motors 69 Key Benefits Enhanced Thermal Model including RTD and Current Unbalance Biasing plete Asset monitoring with programmable RTD inputs for Stator, Bearing and Ambient temperature protection Enhanced reporting

More information

PBM. Motor management system USER S MANUAL. EN_PBM_User-Manual_R011.Docx

PBM. Motor management system USER S MANUAL. EN_PBM_User-Manual_R011.Docx PBM Motor management system USER S MANUAL EN_PBM_User-Manual_R011.Docx 1. RECEPTION, HANDLING, INSTALLATION... 6 1.1. Unpacking... 6 1.2. Reception of relays... 6 1.3. Handling electronic equipment...

More information

C u t l e r- H a m m e r. IQ Analyzer START Q U I C KS TA RT G U I D E

C u t l e r- H a m m e r. IQ Analyzer START Q U I C KS TA RT G U I D E C u t l e r- H a m m e r IQ Analyzer START Q U I C KS TA RT G U I D E C O N T E N T S Introduction 4 Mounting 9 IMPORTANT NOTICE Use this Guide to begin performing basic metering functions quickly, without

More information

Protection and control. Sepam range Sepam 2000 Metering and protection functions

Protection and control. Sepam range Sepam 2000 Metering and protection functions Protection and control Sepam range Sepam 2 Metering and protection functions Contents chapter / page metering functions 1/1 protection functions 2/1 appendix 3/1 Notation c Sepam 2 may include several

More information

AQUAVAR CPC. Modbus Communications (Software Version 204 and later)* INSTRUCTION MANUAL ADAQCPC R1

AQUAVAR CPC. Modbus Communications (Software Version 204 and later)* INSTRUCTION MANUAL ADAQCPC R1 INSTRUCTION MANUAL ADAQCPC R1 AQUAVAR CPC Modbus Communications (Software Version 204 and later)* ADDENDUM TO THE INSTALLATION AND OPERATION MANUAL (IM167) * Aquavar CPC units with software 204 and later

More information

VFS11 Parameter List for up to CPU version 105

VFS11 Parameter List for up to CPU version 105 E65824 VFS Parameter List for up to CPU version 5 Setting Date Customer End user Application Application No/Serial No Inverter s Type-Form Quantity Inverter s Serial No Motor s capacity If user s value

More information

Centrale de mesure Power Meter PM500 Merlin Gerin

Centrale de mesure Power Meter PM500 Merlin Gerin Notice d'installation et d'utilisation Installation and user manual Centrale de mesure Power Meter PM500 Merlin Gerin 059473_D Introduction and description Package contents c one PM500 power meter with

More information

489 Generator Management Relay Instruction Manual

489 Generator Management Relay Instruction Manual Digital Energy Multilin Firmware Revision: 4.0X Manual Part Number: 1601-0150-AF Manual Order Code: GEK-106494P Copyright 2011 GE Multilin 489 Generator Management Relay Instruction Manual GE Multilin

More information

INSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W

INSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W Page 2 / 16 INDEX: GENERAL TYPES ACESSORIES AND OPTIONS INSTALLATION WIRING DIAGRAMS CONNECTING TERMINALS DIAGRAMS WIRING DIAGRAM DESCRIPTION WORKING DESCRIPTION AND KEYBOARD WORKING DESCRIPTION AND PROGRAMMING

More information

ASHIDA Numerical Directional 3OC + 1EF Protection Relay

ASHIDA Numerical Directional 3OC + 1EF Protection Relay Ashida Numerical Directional 3O/C + 1E/F PROTH. PROTH. ERR L5 FAULT PKP PKP FAULT L6 PT DT REC LOCK BF L7 CLOSE TRIP TRIP CLOSE ADR 145B 245B Protection Features: 4 Element (3 Phase + EF +sensitive EF)

More information

Multimeter 500CVD21 RTU500 series

Multimeter 500CVD21 RTU500 series Remote Terminal Units - Data sheet Multimeter 500CVD21 RTU500 series CT/VT interface with 4 voltage and 24 current inputs for direct monitoring of 3/4 wire 0 300 V AC (line to earth), 0...500 V AC (phase

More information

Modbus Integration Integration for Modbus Functionality for VT8300 Series

Modbus Integration Integration for Modbus Functionality for VT8300 Series Modbus Integration Integration for Modbus Functionality for VT8300 Series Building Management System *For data visualization and analysis Modbus Controller VT8000 Series room controllers 2 TABLE OF CONTENTS

More information

HPVFP High Performance Full Function Vector Frequency Inverter

HPVFP High Performance Full Function Vector Frequency Inverter Advanced User Manual HPVFP High Performance Full Function Vector Frequency Inverter HP VER 1.00 1. HPVFP Parameter Set Overview...3 1.1. About this section...3 1.2. Parameter Structure Overview...3 1.3.

More information

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID RI-D140 Three Phase Multifunction DIN Rail Energy Meter (MID Certified) Four module DIN rail mounted Energy pulse LED True RMS measurement Cost effective and accurate Modbus communication -/1A or -/5A

More information

REF 610 Feeder Protection Relay. Technical Reference Manual

REF 610 Feeder Protection Relay. Technical Reference Manual REF 610 1MRS 755310 Issued: 05.10.2004 Version: A/05.10.2004 REF 610 Contents 1. Introduction...6 1.1. About this manual...6 1.2. The use of the relay...6 1.3. Features...6 1.4. Guarantee...8 2. Safety

More information

489 Generator Management Relay

489 Generator Management Relay GE Grid Solutions 489 Generator Management Relay Instruction Manual Product version: 4.0x GE publication code: 1601-0150-AM (GEK-106494W) 1601-0150-AM Copyright 2016 GE Multilin Inc. All rights reserved.

More information

RETROFITTING. Motor Protection Relay. Two mountings are available, Flush Rear Connection (EDPAR) or Projecting Rear Connection (SDPAR).

RETROFITTING. Motor Protection Relay. Two mountings are available, Flush Rear Connection (EDPAR) or Projecting Rear Connection (SDPAR). RETROFITTING Motor Protection Relay NPM800R (R2 case) and NPM800RE (R3 case) are dedicated to the refurbishment of 7000 series (R2 and R3 cases) of CEE relays providing the protection of medium voltage

More information

InfraStruXure Manager v4.x Addendum: Building Management System Integration

InfraStruXure Manager v4.x Addendum: Building Management System Integration InfraStruXure Manager v4.x Addendum: Building Management System Integration Introduction This addendum explains the integration of the APC InfraStruXure Manager Appliance with a Building Management System

More information

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION! INSTALLATION INSTRUCTIONS FOR SYMCOM S OVERLOAD RELAY MODEL 777-MV-FT BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE

More information

CHAPTER KEYPAD OPERATION AND QUICKSTART. In This Chapter... The GS2 Digital Keypad GS2 Quickstart...3 6

CHAPTER KEYPAD OPERATION AND QUICKSTART. In This Chapter... The GS2 Digital Keypad GS2 Quickstart...3 6 CHAPTER KEYPAD OPERATION 3 AND QUICKSTART In This Chapter... The GS2 Digital Keypad.....................3 2 LED Display.........................................3 2 LED Indicators.......................................3

More information

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure New Product News Measuring & Monitoring Relays K8AK/K8DS Series DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays Compact 22.5 mm and 17.5 mm housings Resistant to high-frequency

More information

4111 Usage Minutes 1 Integer RO Y - Minutes 0-59 Y Y YP

4111 Usage Minutes 1 Integer RO Y - Minutes 0-59 Y Y YP Table of Contents 2 Setup & Status Y Y Y Metering Y Y Y Min Max Y Y Y Demand Y Y Y IO Y Y Y Alarms N N Y Reset Commands Y Y Y DL System Y Y Y Notes Y Y Y 5 Setup & Status 24 Usage Hours 2 Float RO Y -

More information

Metasys Integrator Power Measurement Ltd. Application

Metasys Integrator Power Measurement Ltd. Application Metasys Connectivity Technical Manual 629.5 Metasys Integrator Section Application Note Issue Date January 19, 2006 APPLICATION NOTE Metasys Integrator Power Measurement Ltd. Application lntroduction Page

More information

ELECTRICAL NETWORK RECORDER - MC 750 ELECTRICAL NETWORK ANALYZER -MC 760 ENERGY METER - MC 720 POWER METER - MC 710 MULTIFUNCTION METER - MC 740

ELECTRICAL NETWORK RECORDER - MC 750 ELECTRICAL NETWORK ANALYZER -MC 760 ENERGY METER - MC 720 POWER METER - MC 710 MULTIFUNCTION METER - MC 740 ELECTRICAL NETWORK ANALYZER -MC 760 ELECTRICAL NETWORK RECORDER - MC 750 MULTIFUNCTION METER - MC 740 ENERGY METER - MC 720 POWER METER - MC 710 WE RECORD QUANTITIES OF ELECTRICAL NETWORK, MEASURE INSTANTANEOUS

More information

SYMAP. Power Protection Monitoring Diesel Control Power Management. User s Manual

SYMAP. Power Protection Monitoring Diesel Control Power Management. User s Manual SYMAP - Power Protection Monitoring Diesel Control Power Management User s Manual FOR THIS DOCUMENT WE RESERVE ALL RIGHTS. WITHOUT OUR CONSENT IN WRITING IT SHALL NOT BE REPRODUCED BY ANY MEANS NOR BE

More information