Andersen windows and patio doors make it easy to create a wide variety of combination designs.

Size: px
Start display at page:

Download "Andersen windows and patio doors make it easy to create a wide variety of combination designs."

Transcription

1 OMINTION DESIGNS ndersen windows and patio doors make it easy to create a wide variety of combination designs. ombination Types Ribbon ombinations Ribbons are horizontal window combinations (vertical joins) where opposite ends (head and sill) of individual windows are fastened to the building structure. Stack ombinations Stacks are vertical window combinations (horizontal joins) where opposite sides (both side jambs) of individual windows are fastened to the building structure. Determining Design Wind Load Performance Proper combination design in conformance with local wind load requirements is vital to the success of your project. To make sure a combination is safe and that it complies with local building codes, the combination design wind load performance capacity must be determined. orrectly determining this performance capacity involves the following three steps: Two basic configurations are used in combination designs; 1-way configurations or 2-way configurations. 1-Way STEP 1 Determine uilding ode Requirement Make sure that you have the proper local codes and have identified specified compliance values. This calculated value () will be used to determine if the combination will be ac cept able (STEP 3). STEP 2 2-Way Ribbon ombination Stack ombination Determine Product Performance ompare product Performance Grade Rating data to the local building code () requirement. This will show whether the individual units in a com bi na tion design are acceptable. Performance Grade Ratings replaces Design Pressure Ratings for measuring product performance. See page 11 for further information. Multiple Ribbon/Stack ombination 2-way combinations exist when multiple vertical stacks and horizontal ribbons are joined together. Unlike 1-way combinations, the opposite ends/sides (head and sill, or both side jambs) of individual units are not necessarily fastened directly to the building structure. 2-way combinations are joined with both vertical and horizontal joining material and may require reinforced joining materials depending on the local building code requirement for design wind load (measured in pounds per square foot, ). STEP 3 Determine ombination Performance This step helps determine whether a given product, size, configuration and joining material type will meet the local building code design wind load requirement. To determine what joining material type to use (wood, clips,, steel or aluminum), compare the local building code design wind load requirement to the Design Wind Load Table value for a particular joining material on the following pages oastal Product Guide Page 1 of 1

2 ndersen Joining Materials and Installation ccessories For a successful installation, designed to provide the required design pressure, it is important that ndersen joining materials and installation accessories be specified by a project architect or contractor. ndersen offers several types of joining materials. Each creates a joining system that maintains the look of ndersen products. hoose the type appropriate for your combination design. The addition of joining materials will affect the overall rough opening dimension. Read and follow instruction guides in their entirety. Instruction guides are available from your ndersen supplier or by visiting andersenwindows.com. omponents used with each joining system will vary depending on products being joined. heck with your ndersen supplier for more information. ndersen Exterior Trim Strips - variety of trim strips for finishing the join between joined products are available in colors to match ndersen windows and doors. ndersen Interior Wood asing - vailable in several wood types, pre-finished options, sizes and style options including laminated arch casings, decorative plinth and key blocks. Reinforced Joining Materials Materials vary depending on wind load requirements. The structural performance of any combination is only as high as the lowest structural performance rating of any individual window or material in the combination. Reinforced joining materials are used to create product alignment, positive joining and load transfer between the ndersen windows and doors and the rough opening. They provide added strength capable of withstanding a variety of wind load pressures. See joining instructions for specific joining and anchoring components. Laminated Veneer Lumber () Joining - joining material is available for -Series windows and patio doors and 400 Series windows. oth x 3 4 (19) and x 3 4 (19) are available and include an aluminum exterior trim retainer. materials are available in a variety of lengths up to 10'. Steel Joining - Steel joining material is available for 400 Series windows in 8' (2445), 9'-6 and 12'-6 (3810) lengths. Treated for corrosion resistance, the 4 (102) width material provides strength and rigidity. djacent windows attach to the steel joining with screws provided in the kit. luminum Joining - luminum joining material is available for 400 Series windows in 6' (1831) and 7'-8 (2337) lengths. High-quality aluminum provides increased stiffness and is anodized for corrosion resistance. luminum joining stays within the basic jamb of the window so interior casing can be used without extension jambs. djacent windows attach to aluminum joining with screws provided in the kit. Non-Reinforced Joining Materials Materials vary depending on type of windows being joined and wind load requirements. Narrow joining materials are used to create alignment and positive joining between windows. Joining materials are not connected to the rough opening structure. Joining material is contained within the basic jambs so ndersen interior casing can be applied without the use of extension jambs. See joining instructions for specific joining and anchoring components. 1-Way lip Joining -Series: asement, wning, Double-Hung, Picture, Transom and Specialty Windows verage djacent Window Dimension ( + ) 2 = 10' ( + ) 2 = 9' ( + ) 2 = 9' ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = 5'-0 (1524) ( + ) 2 = 4'-6 (1372) ( + ) 2 = 4'-0 (1219) ( + ) 2 = 3'-6 (1067) ( + ) 2 = 3'-0 (914) ( + ) 2 = 2'-6 (762) ( + ) 2 = 2'-0 (610) ( + ) 2 = 1'-6 (457) = (length of join) Structural performance of any combination is only as high as the lowest structural performance of any individual unit or joining material in the combination. ndersen products must be installed and anchored properly according to joining and installation guides to meet rated structural performance. Refer to product joining and installation guides at andersenwindows.com. 3 / 4 (19) lips 2014 oastal Product Guide Page 2 of 1

3 OMINTION DESIGNS 1-Way Joining -Series: asement, wning, Double-Hung, Picture, Transom and Specialty Windows ( + ) 2 = 10' ( + ) 2 = 9' ( + ) 2 = 9' ( + ) 2 = ( + ) 2 = verage djacent Window Dimension ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = 5'-0 (1524) ( + ) 2 = 4'-6 (1372) ( + ) 2 = 4'-0 (1219) ( + ) 2 = 3'-6 (1067) ( + ) 2 = 3'-0 (914) x 3 / 4 (19) ( + ) 2 = 2'-6 (762) ( + ) 2 = 2'-0 (610) ( + ) 2 = 1'-6 (457) = (length of join) 9'-0 9'-6 1-Way Joining -Series: asement, wning, Double-Hung, Picture, Transom and Specialty Windows ( + ) 2 = 10' ( + ) 2 = 9' ( + ) 2 = 9' ( + ) 2 = ( + ) 2 = verage djacent Window Dimension ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = 5'-0 (1524) ( + ) 2 = 4'-6 (1372) ( + ) 2 = 4'-0 (1219) ( + ) 2 = 3'-6 (1067) ( + ) 2 = 3'-0 (914) x 3 / 4 (19) ( + ) 2 = 2'-6 (762) ( + ) 2 = 2'-0 (610) ( + ) 2 = 1'-6 (457) = (length of join) 9'-0 9'-6 10'-0 ndersen products must be installed and anchored properly according to joining and installation guides to meet rated structural performance. Refer to product joining and installation guides at andersenwindows.com oastal Product Guide Page 3 of 1

4 2-Way Joining -Series: asement, wning, Double-Hung, Picture, Transom and Specialty Windows verage djacent Window Dimension ( + ) 2 = 42 ( + ) 2 = 45 ( + ) 2 = 50 ( + ) 2 = 5'-0 (1524) ( + ) 2 = 4'-6 (1372) ( + ) 2 = 4'-0 (1219) ( + ) 2 = 3'-6 (1067) ( + ) 2 = 3'-0 (914) ( + ) 2 = 2'-6 (762) ( + ) 2 = 2'-0 (610) ( + ) 2 = 1'-6 (457) = (length of join) 9'-0 x 3 / 4 (19) 2-Way Joining -Series: asement, wning, Double-Hung, Picture, Transom and Specialty Windows ( + ) 2 = 10' ( + ) 2 = 9' ( + ) 2 = 9' ( + ) 2 = verage djacent Window Dimension ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = 5'-0 (1524) ( + ) 2 = 4'-6 (1372) ( + ) 2 = 4'-0 (1219) ( + ) 2 = 3'-6 (1067) ( + ) 2 = 3'-0 (914) x 3 / 4 (19) ( + ) 2 = 2'-6 (762) ( + ) 2 = 2'-0 (610) ( + ) 2 = 1'-6 (457) = (length of join) 9'-0 9'-6 10'-0 ndersen products must be installed and anchored properly according to joining and installation guides to meet rated structural performance. Refer to product joining and installation guides at andersenwindows.com oastal Product Guide Page 4 of 1

5 OMINTION DESIGNS 1-Way Wood Joining 400 Series: PG Upgrade asement, wning and Flexiframe Windows ( + ) 2 = 12'-6 (3810) ( + ) 2 = 12'-0 (3658) ( + ) 2 = 11'-6 (3505) ( + ) 2 = 11'-0 (3353) ( + ) 2 = 10'-6 (3200) ( + ) 2 = 10' verage djacent Window Dimension ( + ) 2 = 9' ( + ) 2 = 9' ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = 5'-0 (1524) PG Upgrade Only Wood Joining Material Note: Stacking of windows is allowed to a maximum height of 12'-6 (3810). ontact your ndersen supplier for information about taller combination heights. ( + ) 2 = 4'-6 (1372) ( + ) 2 = 4'-0 (1219) ( + ) 2 = 3'-6 (1067) ( + ) 2 = 3'-0 (914) ( + ) 2 = 2'-6 (762) ( + ) 2 = 2'-0 (610) ( + ) 2 = 1'-6 (457) = (length of join) 3'-6 (1067) 4'-0 (1219) 4'-6 (1372) 5'-0 (1524) 2-Way Wood Joining 400 Series: PG Upgrade asement, wning and Flexiframe Windows verage djacent Window Dimension ( + ) 2 = 41 ( + ) 2 = 45 ( + ) 2 = 48 ( + ) 2 = 53 ( + ) 2 = 5'-0 (1524) ( + ) 2 = 4'-6 (1372) ( + ) 2 = 4'-0 (1219) ( + ) 2 = 3'-6 (1067) ( + ) 2 = 3'-0 (914) ( + ) 2 = 2'-6 (762) ( + ) 2 = 2'-0 (610) Width Height PG Upgrade Only Wood Joining Material ( + ) 2 = 1'-6 (457) = (length of join) 3'-0 (914) 3'-6 (1067) 4'-0 (1219) 4'-6 (1372) 5'-0 (1524) ndersen products must be installed and anchored properly according to joining and installation guides to meet rated structural performance. Refer to product joining and installation guides at andersenwindows.com oastal Product Guide Page 5 of 1

6 1-Way or 2-Way luminum Joining 400 Series: asement, wning and Flexiframe Windows verage djacent Window Dimension ( + ) 2 = 9' ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = 5'-0 (1524) ( + ) 2 = 4'-6 (1372) ( + ) 2 = 4'-0 (1219) ( + ) 2 = 3'-6 (1067) ( + ) 2 = 3'-0 (914) ( + ) 2 = 2'-6 (762) ( + ) 2 = 2'-0 (610) ( + ) 2 = 1'-6 (457) = (length of join) 4'-0 (1219) 4'-6 (1372) 5'-0 (1524) luminum Joining Material E = 10 x 10 6 psi, l (IS x - x) =.59 in T6 luminum For a join with a continuous jamb on one side, multiply by 1.2. For a join with a continuous jamb on both sides, multiply by Way or 2-Way Steel Joining 400 Series: asement, wning and Flexiframe Windows verage djacent Window Dimension ( + ) 2 = 12'-6 (3810) 50 ( + ) 2 = 12'-0 (3658) 52 ( + ) 2 = 11'-6 (3505) ( + ) 2 = 11'-0 (3353) ( + ) 2 = 10'-6 (3200) ( + ) 2 = 10' ( + ) 2 = 9' ( + ) 2 = 9' ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = 5'-0 (1524) ( + ) 2 = 4'-6 (1372) ( + ) 2 = 4'-0 (1219) ( + ) 2 = 3'-6 (1067) ( + ) 2 = 3'-0 (914) ( + ) 2 = 2'-6 (762) ( + ) 2 = 2'-0 (610) ( + ) 2 = 1'-6 (457) = (length of join) 3'-0 (914) 3'-6 (1067) 4'-0 (1219) 4'-6 (1372) 5'-0 (1524) 4 (102) x 3 / 16 (5) Steel Joining Material E = 29 x 10 6 psi, l (IS x - x) = 1.0 in 4 36 hot rolled steel 9'-0 9'-6 For a join with a continuous jamb on one side, multiply by 1.2. For a join with a continuous jamb on both sides, multiply by 1.4. ndersen products must be installed and anchored properly according to joining and installation guides to meet rated structural performance. Refer to product joining and installation guides at andersenwindows.com oastal Product Guide Page 6 of 1

7 OMINTION DESIGNS 1-Way Joining 400 Series: asement, wning and Flexiframe Windows verage djacent Window Dimension ( + ) 2 = ( + ) 2 = ( + ) 2 = 5'-0 (1524) ( + ) 2 = 4'-6 (1372) ( + ) 2 = 4'-0 (1219) ( + ) 2 = 3'-6 (1067) ( + ) 2 = 3'-0 (914) ( + ) 2 = 2'-6 (762) ( + ) 2 = 2'-0 (610) ( + ) 2 = 1'-6 (457) = (length of join) x 3 / 4 (19) 2-Way Joining 400 Series: asement, wning and Flexiframe Windows verage djacent Window Dimension verage djacent Window Dim. ( + ) 2 = ( + ) 2 = ( + ) 2 = 5'-0 (1524) ( + ) 2 = 4'-6 (1372) ( + ) 2 = 4'-0 (1219) ( + ) 2 = 3'-6 (1067) ( + ) 2 = 3'-0 (914) ( + ) 2 = 2'-6 (762) = (length of join) 4'-0 (1219) 4'-6 (1372) 5'-0 (1524) ( + ) 2 = 10' ( + ) 2 = 9' ( + ) 2 = 9' ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = 5'-0 (1524) ( + ) 2 = 4'-6 (1372) ( + ) 2 = 4'-0 (1219) ( + ) 2 = 3'-6 (1067) ( + ) 2 = 3'-0 (914) ( + ) 2 = 2'-6 (762) ( + ) 2 = 2'-0 (610) ( + ) 2 = 1'-6 (457) = (length of join) 9'-0 9'-6 10'-0 x 3 / 4 (19) 2-way joining must be assembled on the jobsite within the rough opening. x 3 / 4 (19) ndersen products must be installed and anchored properly according to joining and installation guides to meet rated structural performance. Refer to product joining and installation guides at andersenwindows.com oastal Product Guide Page 7 of 1

8 1-Way or 2-Way Steel Joining 400 Series: Tilt-Wash Double-Hung Windows verage djacent Window Dimension ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = 5'-0 (1524) ( + ) 2 = 4'-6 (1372) ( + ) 2 = 4'-0 (1219) ( + ) 2 = 3'-6 (1067) ( + ) 2 = 3'-0 (914) ( + ) 2 = 2'-6 (762) ( + ) 2 = 2'-0 (610) = (length of join) 4 (102) x 3 / 16 (5) Steel Joining Material E = 29 x 10 6 psi, l (IS x - x) = 1.0 in 4 36 hot rolled steel 9'-0 9'-6 This table shows value up to 50 to accommodate combinations of PG Upgrade windows. The rating of a combination cannot exceed the lowest rating of the individual windows used. V-Notch Gusset Plate 1-Way Joining 400 Series: Tilt-Wash Double-Hung, Picture and Transom Windows verage djacent Window Dimension ( + ) 2 = ( + ) 2 = ( + ) 2 = 5'-0 (1524) ( + ) 2 = 4'-6 (1372) ( + ) 2 = 4'-0 (1219) ( + ) 2 = 3'-6 (1067) ( + ) 2 = 3'-0 (914) ( + ) 2 = 2'-6 (762) ( + ) 2 = 2'-0 (610) ( + ) 2 = 1'-6 (457) ( + ) 2 = 1'-0 (457) = (length of join) x 3 / 4 (19) verage djacent Window Dimension ( + ) 2 = 10' ( + ) 2 = 9' ( + ) 2 = 9' ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = 5'-0 (1524) ( + ) 2 = 4'-6 (1372) ( + ) 2 = 4'-0 (1219) ( + ) 2 = 3'-6 (1067) ( + ) 2 = 3'-0 (914) ( + ) 2 = 2'-6 (762) ( + ) 2 = 2'-0 (610) ( + ) 2 = 1'-6 (457) = (length of join) 9'-0 Note: 2-way joining must be assembled on the jobsite within the rough opening. When creating 2-way combinations minimum wall thickness, joining material is required. 9'-6 10'-0 x 3 / 4 (19) Structural performance of any combination is only as high as the lowest structural performance of any individual unit or joining material in the combination. ndersen products must be installed and anchored properly according to joining and installation guides to meet rated structural performance. Refer to product joining and installation guides at andersenwindows.com oastal Product Guide Page 8 of 1

9 OMINTION DESIGNS 1-Way Joining -Series Frenchwood Patio Doors: Gliding, Hinged Inswing, Hinged Outswing, Transoms and Sidelights verage djacent Door/Transom/Sidelight Dimension ( + ) 2 = 10' ( + ) 2 = 9' ( + ) 2 = 9' ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = 5'-0 (1524) ( + ) 2 = 4'-6 (1372) ( + ) 2 = 4'-0 (1219) ( + ) 2 = 3'-6 (1067) ( + ) 2 = 3'-0 (914) ( + ) 2 = 2'-6 (762) ( + ) 2 = 2'-0 (610) ( + ) 2 = 1'-6 (457) ' Max. When joining hinged inswing or outswing patio doors do not join hinge jamb to hinge jamb. = (length of join) 9'-0 9'-6 10'-0 x 3 / 4 (19) 1-Way Joining -Series Frenchwood Patio Doors: Gliding, Hinged Inswing, Hinged Outswing, Transoms and Sidelights verage djacent Door/Transom/Sidelight Dimension ( + ) 2 = 10' ( + ) 2 = 9' ( + ) 2 = 9' ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ' Max. 8' Max. 8' Max. ( + ) 2 = ( + ) 2 = 5'-0 (1524) ( + ) 2 = 4'-6 (1372) ( + ) 2 = 4'-0 (1219) ( + ) 2 = 3'-6 (1067) ( + ) 2 = 3'-0 (914) ( + ) 2 = 2'-6 (762) ( + ) 2 = 2'-0 (610) ( + ) 2 = 1'-6 (457) ' Max. When joining hinged inswing or outswing patio doors do not join hinge jamb to hinge jamb. = (length of join) 9'-0 9'-6 10'-0 x 3 / 4 (19) ndersen products must be installed and anchored properly according to joining and installation guides to meet rated structural performance. Refer to product joining and installation guides at andersenwindows.com oastal Product Guide Page 9 of 1

10 2-Way Joining -Series Frenchwood Patio Doors: Gliding, Hinged Inswing, Hinged Outswing, Transoms and Sidelights verage djacent Door/Transom/Sidelight Dimension ( + ) 2 = 10' ( + ) 2 = 9' ( + ) 2 = 9' ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = 5'-0 (1524) ( + ) 2 = 4'-6 (1372) ( + ) 2 = 4'-0 (1219) ( + ) 2 = 3'-6 (1067) ( + ) 2 = 3'-0 (914) ( + ) 2 = 2'-6 (762) ( + ) 2 = 2'-0 (610) ( + ) 2 = 1'-6 (457) = (length of join) 9'-0 9'-6 10' Max. 10'-0 When joining hinged inswing or outswing patio doors do not join hinge jamb to hinge jamb. x 3 / 4 (19) 2-Way Joining -Series Frenchwood Patio Doors: Gliding, Hinged Inswing, Hinged Outswing, Transoms and Sidelights verage djacent Door/Transom/Sidelight Dimension ( + ) 2 = 10' ( + ) 2 = 9' ( + ) 2 = 9' ( + ) 2 = ' ( + ) 2 = Max. ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = ( + ) 2 = 5'-0 (1524) ( + ) 2 = 4'-6 (1372) ( + ) 2 = 4'-0 (1219) ( + ) 2 = 3'-6 (1067) ( + ) 2 = 3'-0 (914) ( + ) 2 = 2'-6 (762) ( + ) 2 = 2'-0 (610) ( + ) 2 = 1'-6 (457) = (length of join) 9'-0 9'-6 10'-0 When joining hinged inswing or outswing patio doors do not join hinge jamb to hinge jamb. x 3 / 4 (19) ndersen products must be installed and anchored properly according to joining and installation guides to meet rated structural performance. Refer to product joining and installation guides at andersenwindows.com oastal Product Guide Page 10 of 1

11 PRODUT PERFORMNE Performance Standards The Window and Door Manufacturers ssociation (WDM), The merican rchitectural Manufacturers ssociation (M) and the anadian Standards ssociation (S) have jointly released M/WDM/S 101/I.S.2/440-08; North merican Fenestration Standard/ Specification for Windows, Doors and Skylights, which calls for using Performance Grade as the new rating to describe products that comply to the standard. This new version dated -08 has been adopted by the 2009 International uilding ode (I) and the International Residential ode (IR). Performance Grade ratings are being used to replace Design Pressure Ratings as the preferred method of measuring product performance throughout the window, door and skylight industry to define products that comply with all of the requirements of the 101/I.S.2/440 standard. product only achieves a Performance Grade or PG rating if that product complies with not only the structural loading requirement, but all other performance requirements such as air infiltration resistance, water penetration resistance, ease of operation and resistance to forced entry. Design Pressure Rating or DP rating will now describe a product rating that has only been tested to structural loading and not air infiltration, water testing or other requirements for Performance Grade. Performance lasses This Standard/Specification defines requirements for four performance classes. The performance classes are designated R, L, W, and W. This classification system provides for several levels of performance. Product selection is always based on the performance requirements of the particular project. Elements of Performance Grade (PG) Designations In order to qualify for a given performance grade (PG), test specimens need to pass all required performance tests for the following, in addition to all required auxiliary (durability) tests (not shown here) for the applicable product type and desired performance class: (a) Operating force (if applicable): minimum and maximum operating force vary by product type and performance class. (b) ir leakage resistance: tested in accordance with STM E283 at a test pressure of The allowable air infiltration for R, L & W is 0.3 cubic feet per minute per square foot of frame (cfm/ft 2 ). (c) Water penetration resistance: tested in accordance with STM E547 with the specified test pressure applied per M/WDM/S 101/I.S.2/ The test consists of four cycles. Each cycle consists of five minutes with pressure applied and one minute with the pressure released, during which the water spray is continuously applied. The water spray shall be uniformly applied at a constant rate of 5.0 U.S. gal/ft 2 hr. d) Uniform load deflection test: tested in accordance with STM E330 for both positive and negative pressure (pressure defined by M/WDM/S 101/I.S.2/440-08) with the load maintained for a period of 60 seconds. fter loads are removed there shall be no more permanent deformation in excess of 0.4% of its span and no damage to the unit which would make it inoperable. Starting with the 2008 specification, design pressure (DP) will only represent the uniform load deflection test. (e) Uniform load structural test: tested in accordance with STM E330 for both positive and negative pressure (pressure defined by M/WDM/S 101/I.S.2/440-08) with the load maintained for a period of 10 seconds. fter loads are removed there shall be no damage to the unit which would make it inoperable. (f) Forced-entry resistance (if applicable): tested in accordance with STM F588 (Windows), F476 (Swinging Doors) and F842 (Sliding Doors) at a performance level 10 rating. Maximum Size Tested (MST) Test size is a factor in determining compliance with this Standard/Specification. Each product type and class has a defined minimum set of requirements. The minimum test size increases with each class (i.e. R, L, W or W). Minimum Requirements The minimum requirements to obtain a Performance Grade (PG) are listed below: Product Performance lass Minimum Performance Grade (PG) () Minimum Design Pressure (DP) () Minimum Structural Test Pressure (STP) () Minimum Water Penetration Test Pressure (WTP) () Windows and Doors R L W W Structural Test Pressure (STP) is 150% of the Performance Grade (PG) for windows and doors. Water Penetration Test Pressure (WTP) is 15% of the Performance Grade (PG) oastal Product Guide Optional Higher Performance Grades (PG) & orresponding Test Pressures () PG20 PG25 PG30 PG35 PG40 PG45 PG50 PG55 PG60 WTP DP STP ir Forced Entry Resistance (FER) is always a performance level 10 regardless of Performance Grade (PG). Minimum and maximum Operating Force varies by product type. Hallmark ertification The Window and Door Manufacturers ssociation (WDM) sponsored Hallmark ertification Program is designed to provide builders, architects, specifiers and consumers with an easily recognizable means of identifying products that have been manufactured in accordance with the appropriate WDM and other referenced performance standards. onformance is determined by periodic in-plant inspections by a third party administrator. The inspections include auditing licensee quality control procedures and processes, and a review to confirm products are manufactured in accordance with the appropriate performance standards. Periodic testing of representative product constructions and components by a third party testing laboratory is also required. When all of the program requirements are met, the licensee is authorized to use the WDM Hallmark registered logo on the ertification Label as a means of identifying products. Products successfully obtaining Hallmark ertification will be labeled with a 3-part code, which includes performance class, performance grade and maximum size tested. elow is a sample certification label: Hallmark ertified STNDRD M/WDM/S 101/I.S.2/ M/WDM/S 101/I.S.2/ STM E / STM E ndersen orporation 400 SERIES SEMENT WINDOW Manufacturer Stipulates onformance as indicated below RTING LSS L (1) PG70 (2) SIZE TESTED in. (3) DP+70/-70 (4) -L70 DP + 70/-70 Wind Zone 4, Missile Level D, Design Pressure 70/70 psf (1) Performance lass (2) Performance Grade (3) Size Tested (4) Design Pressure In the example above, the performance class is L, the performance grade (PG) is 70 and the size tested is 31.5 x What this means to the specifier is, based on the optional higher performance grade chart, the laboratory tested air infiltration was less than 0.3 cfm/ft 2 (test pressure is always 1.57 and the allowable airflow is 0.3 cfm/ft 2 ), the product tested successfully resisted a laboratory water penetration test at a test pressure of 10.5 (test pressure equals 15% of PG), the product tested successfully withstood a laboratory positive and negative structural test at a pressure of 105 (test pressure equals 150% of performance grade) in both the positive and negative directions and the product tested passed the laboratory requirements for operational force and forced entry resistance. ased on this test, all products smaller in both width and height can be labeled with this product performance rating. Important uilding codes prescribe Performance Grade (PG) based on a variety of criteria (i.e. windspeed zone, building height, etc.), therefore structural test pressures should not be used for code compliance. In the example above, a PG 70 performance grade rating, which passes a 70 design pressure, should be used for determining code compliance, not the structural test pressure of 105. If you need further details about how ndersen products perform to this standard, contact your ndersen supplier. If you need further information about the M/WDM/S 101/I.S.2/ standard or the Hallmark ertification Program please contact: WDM, 401 N. Michigan venue, Suite 2200 hicago, Il Phone: Web: wdma.com Where designated, ndersen products are tested, certified and labeled to the requirements of the Hallmark ertification Program. ctual performance may vary based on variations in manufacturing, shipping, installation, environmental conditions and conditions of use. Page 11 of 1

Steel Reinforced Joining Thank you for choosing Andersen. Please leave this guide with building owner.

Steel Reinforced Joining Thank you for choosing Andersen. Please leave this guide with building owner. Steel Reinforced Joining (Horizontal/Vertical) for Andersen 400 Series Woodwright & Tilt-Wash Double-Hung, Picture, and Transom Windows and 400 Series Double-Hung Half Circle and Flexiframe Specialty Windows

More information

F r e n c h w o o d G l i d i n g P a t i o D o o r s

F r e n c h w o o d G l i d i n g P a t i o D o o r s Contents Frenchwood Gliding Patio Doors Basic Unit Details Two and Four Panel...9-2 Sidelight...9-5 Options / Accessories Ramped Insert - Interior and Exterior...9-6 Grilles...9-7 Anchoring Methods...9-9

More information

Definitions and Design Considerations... W-CR-2

Definitions and Design Considerations... W-CR-2 General Information SECTION DIRECTORY Definitions and Design Considerations... W-CR-2 Combination Assembly Recommendations and Limitations Typical Sealant... W-CR-4 Single-Unit Opening... W-CR-4 Two-Way

More information

26- H i n g e d P a t i o D o o r s - I n s w i n g

26- H i n g e d P a t i o D o o r s - I n s w i n g Contents Hinged Patio Doors - Inswing Basic Unit Details... 2 Options / Accessories Accessibility Option... 5 Andersen Grilles... 6 Extension s... 7 Anchoring Methods... 8 Joining Details... 9 Suggested

More information

Steel Reinforced Joining Guide (Horizontal / Vertical)

Steel Reinforced Joining Guide (Horizontal / Vertical) (Horizontal / Vertical) for Andersen Patio Door and/or Elliptical Top Window Combinations Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation

More information

ASPEN 530 T SINGLE HUNG. Each lite of glass was channel glazed with a reducing vinyl gasket.

ASPEN 530 T SINGLE HUNG. Each lite of glass was channel glazed with a reducing vinyl gasket. TESTED FOR Date : July 29, 2004 FLEETWOOD ALUMINUM PRODUCTS Page : 1 of 5 2485 Railroad Street Corona, CA 91720 1.0 PURPOSE The purpose of this report is to present the testing methods employed and the

More information

for Andersen Frenchwood Hinged and Outswing Patio Doors, Sidelights, and Transoms

for Andersen Frenchwood Hinged and Outswing Patio Doors, Sidelights, and Transoms for Andersen Frenchwood Hinged and Outswing Patio Doors, Sidelights, and Transoms Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation and maintenance

More information

TESTED FOR Report No. : A04H-009 Date : February 10, 2004 FLEETWOOD ALUMINUM PRODUCTS, INC. Page : 1 of Railroad Street Corona, CA 91720

TESTED FOR Report No. : A04H-009 Date : February 10, 2004 FLEETWOOD ALUMINUM PRODUCTS, INC. Page : 1 of Railroad Street Corona, CA 91720 TESTED FOR Date : February 10, 2004 FLEETWOOD ALUMINUM PRODUCTS, INC. Page : 1 of 5 2485 Railroad Street Corona, CA 91720 1.0 PURPOSE The purpose of this report is to present the testing methods employed

More information

Read guide from beginning to end before starting installation. Read all warnings and cautions during unit installation.

Read guide from beginning to end before starting installation. Read all warnings and cautions during unit installation. Installation Guide for E-Series/Eagle High-Performance Mullion Windows with LVL Reinforcement and Installed Using Type B Clips Thank you for choosing Andersen. Instructions are for typical, new wood-framed

More information

Non-Reinforced Joining Guide (1-Way Vertical or Horizontal) for Andersen 200 Series Tilt-Wash Double-Hung Windows and Complementary Products

Non-Reinforced Joining Guide (1-Way Vertical or Horizontal) for Andersen 200 Series Tilt-Wash Double-Hung Windows and Complementary Products (1-Way Vertical or Horizontal) for Andersen 200 Series Tilt-Wash Double-Hung Windows and Complementary Products Non-Reinforced Joining Guide Congratulations! You have just purchased one of the many fine

More information

Architectural Testing AAMA 501 TEST REPORT. Report Number: C Rendered to: Tubelite, Inc. Walker, Michigan

Architectural Testing AAMA 501 TEST REPORT. Report Number: C Rendered to: Tubelite, Inc. Walker, Michigan Architectural Testing AAMA 501 TEST REPORT Report Number: C1529.01-450-44 Rendered to: Tubelite, Inc. Walker, Michigan MODEL DESIGNATION: E4500 PRODUCT TYPE: Non-Thermal Storefront This report contains

More information

Non-Reinforced Joining Guide (2-Way Horizontal and Vertical Joining) for Andersen 200 Series Tilt-Wash Double-Hung and Transom Windows

Non-Reinforced Joining Guide (2-Way Horizontal and Vertical Joining) for Andersen 200 Series Tilt-Wash Double-Hung and Transom Windows (2-Way Horizontal and Vertical Joining) for Andersen 200 Series Tilt-Wash Double-Hung and Transom Windows Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly,

More information

TAS 201, TAS 202, TAS 203 and ASTM E330 PERFORMANCE TEST REPORT. Rendered to: DIAMOND DOOR PRODUCTS

TAS 201, TAS 202, TAS 203 and ASTM E330 PERFORMANCE TEST REPORT. Rendered to: DIAMOND DOOR PRODUCTS Architectural Testing TAS 201, TAS 202, TAS 203 and ASTM E330 PERFORMANCE TEST REPORT Rendered to: DIAMOND DOOR PRODUCTS SERIES/MODEL: Diamond GEM 130 MPH Series PRODUCT TYPE: Out-Swing Steel Entry Door

More information

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Rendered to: FLEETWOOD WINDOWS AND DOORS Corona, California

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Rendered to: FLEETWOOD WINDOWS AND DOORS Corona, California MIAMI-DADE COUNTY PERFORMANCE TEST REPORT This report contains in its entirety: Cover Page: 1 page Report Body: 14 pages Sketch: 1 page Drawings: 5 pages Report No.: E8384.03-301-18 Rendered to: FLEETWOOD

More information

Panel Assembly and Installation

Panel Assembly and Installation Assembly and Installation Assembly and Installation for Andersen 400 Series Frenchwood, 200 Series Narroline, 200 Series Perma-Shield Gliding Patio Doors and 400 Series Perma-Shield Gliding Patio Doors

More information

Installation Guide for Andersen 400 Series Tilt-Wash Transom and 200 Series Narroline Transom Windows

Installation Guide for Andersen 400 Series Tilt-Wash Transom and 200 Series Narroline Transom Windows for Andersen 400 Series Tilt-Wash Transom and 200 Series Narroline Transom Windows Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation and maintenance

More information

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit. Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit. Installer: Read these instructions completely before starting any installation.

More information

Site Preparation Information for:

Site Preparation Information for: Site Preparation Information for: Product Series - Big Doors Product Type - MultiGlide Door Read these instructions and the Product Safety Information before starting procedure. For: MultiGlide Door Instructions/Videos

More information

Dear Contractor, I am glad that you are interested in our window rebate program.

Dear Contractor, I am glad that you are interested in our window rebate program. Dear Contractor, I am glad that you are interested in our window rebate program. I have included three documents with this letter. One is our form to indicate your intention to participate in the program.

More information

Tools required by installer: Materials required by installer:

Tools required by installer: Materials required by installer: Installation Guidelines For Quaker Window Products Vinyl product line (Single Hung, Double Hung, Sliding Window, Fixed Window, Casement, Awning, and Hopper) Installer: Read these instructions completely

More information

Wood Facade Systems. Made in the U.S.A. Curtain Walls Skylights & Structures Doors & Windows.

Wood Facade Systems. Made in the U.S.A. Curtain Walls Skylights & Structures Doors & Windows. Wood Facade Systems by Solar Innovations, Inc. Single Source Supplier of Wood and Aluminum Products Where Sustainability Meets Innovation Curtain Walls Skylights & Structures Doors & Windows Made in the

More information

MULTISLIDE DOORS INSTALLATION GUIDE & SITE PREPARATION

MULTISLIDE DOORS INSTALLATION GUIDE & SITE PREPARATION MULTISLIDE DOORS INSTALLATION GUIDE & SITE PREPARATION TOOLS AND SUPPLIES 1 TOOLS CHECK LIST 1. laser level 2. hammer 3. pry bars 4. ladders 5. utility knife 6. screw gun 7. applicator foam gun 8. "j"

More information

Installation Guide for Andersen Frenchwood Patio Door Sidelights and Transoms

Installation Guide for Andersen Frenchwood Patio Door Sidelights and Transoms for Andersen Frenchwood Patio Door Sidelights and Transoms Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation and maintenance are essential if

More information

FINISH GROUPS #17 GRP #17 CLEAR

FINISH GROUPS #17 GRP #17 CLEAR EFFECTIVE FEBRUARY 1, 2018 CONTENTS A3/1 CONTENTS SECTION A3...DOOR CLOSERS PAGE SURFACE MOUNTED CLOSERS... A3/2 A3/3 CALIBRE TM CLOSERS... A3/4 INTERNATIONAL CONCEALED CLOSERS... A3/5 CONCEALED CLOSER

More information

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN MINNEAPOLIS, MN 2-0- 2-- General Notes Abbreviations Deviations from Architectural Specifications Deviations from Architectural Drawings ALUM. = ALUMINUM B.O. = BY OTHERS CONT. = CONTINUOUS. = CLEARANCE

More information

Installation Guidelines For ALUMINUM M-SERIES 3 PANEL SLIDING DOOR

Installation Guidelines For ALUMINUM M-SERIES 3 PANEL SLIDING DOOR www.quakerwindows.comv www.quakercommercialwindows.com PO Box 128 504 Highway 63 South Freeburg, MO 65035 800-347-0438 573-469-4151 (fax) Installation Guidelines For ALUMINUM M-SERIES 3 PANEL SLIDING DOOR

More information

INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS

INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS 2008 Pella Corporation Part Number: 803V0101 INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS Installation Instructions for Typical Wood Frame Construction. These instructions were developed

More information

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY. PRODUCT TYPE: 6' x 8' Double Inswing Hardwood Door with Half Circle Transom

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY. PRODUCT TYPE: 6' x 8' Double Inswing Hardwood Door with Half Circle Transom PERFORMANCE TEST REPORT Rendered to: GLASSCRAFT DOOR COMPANY PRODUCT TYPE: 6' x 8' Double Inswing Hardwood Door with Half Circle Transom Title Uniform Load Deflection Test Pressure Uniform Load Structural

More information

MANUFACTURING INC. Specifications

MANUFACTURING INC. Specifications Page 1 of 4 GENERAL 11 Aluminum security screen doors must be tested by a recognized testing laboratory to conform to SMA 6001-2002 Proposed American National Standard Specifications for Metal Protection

More information

Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions

Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions PO Box 480 Ph: 417-235-7821 Monett, MO 65708 Fax: 417-737-7140 Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions These installation instructions are recommendations

More information

Originally Issued: 04/28/2010 Revised: 03/26/2019 Valid Through: 04/30/2020

Originally Issued: 04/28/2010 Revised: 03/26/2019 Valid Through: 04/30/2020 TEMO, IN. 20400 Hall Road linton Township, MI 48038 www.temosunrooms.com PATIO OVER ENLOSURE SI Section: 10 73 00 Protective overs 1.0 REOGNITION TEMO Inc. Patio over Enclosures have been evaluated for

More information

ASTM E 1886 and ASTM E 1996 TEST REPORT. Rendered to: PRL ALUMINUM ARCHITECTURAL PRODUCTS City of Industry, California

ASTM E 1886 and ASTM E 1996 TEST REPORT. Rendered to: PRL ALUMINUM ARCHITECTURAL PRODUCTS City of Industry, California Architectural Testing ASTM E 1886 and ASTM E 1996 TEST REPORT Report No.: D1090.02-301-44 Rendered to: PRL ALUMINUM ARCHITECTURAL PRODUCTS City of Industry, California PRODUCT TYPE: Bi-Fold Door SERIES/MODEL:

More information

b. B aluminum and aluminum-alloy extruded bar, rod, wire, shape and tube

b. B aluminum and aluminum-alloy extruded bar, rod, wire, shape and tube MODEL 240I SECTION 08120 FLUSH ALUMINUM DOORS AND FRAMES PART I GENERAL 1.01 SCOPE OF WORK A. Furnish all labor, materials, equipment and incidentals required to deliver and install aluminum doors, frames,

More information

Marvin Patio Doors VALUE THROUGH AND THROUGH

Marvin Patio Doors VALUE THROUGH AND THROUGH Marvin Patio Doors VALUE THROUGH AND THROUGH 2 Learn more at Marvin.com at our very core, we are craftspeople who take pride in building the right way. that is why, just like every window, we build each

More information

Wall bracing is one of the most important structural elements of

Wall bracing is one of the most important structural elements of CONTINUINGEDUCATION Wall Bracing and the Codes Introduction Wall bracing is one of the most important structural elements of any house, but it can also be one of the most confusing, because designing houses

More information

STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS

STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS 1290363 Revision 1 12/16 Page 1 Weather Shield Mfg., Inc. NOTICE CAUTION! Failure to install and maintain our product according to these instructions

More information

LIST PRICING. Standard Door Modifications

LIST PRICING. Standard Door Modifications Standard Modifications 6/8 Slab Only (No Jamb) *deduct from standard door unit price - $120 7/0 and 8/0 Slab Only (No Jamb) *deduct from standard door unit price -$160 Sidelite Panel Only (No Jamb) *deduct

More information

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION & GLOSSARY ROUGH OPENINGS

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION & GLOSSARY ROUGH OPENINGS Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for Vinyl windows with an integral nailing fin. While the use of these installation instructions

More information

Finish 1 Year 1 Year Lifetime 9200 Inswing Warranty Painted Plated PVD Vinyl Swinging Door List Price White Chrome S.Nickel H.Duty

Finish 1 Year 1 Year Lifetime 9200 Inswing Warranty Painted Plated PVD Vinyl Swinging Door List Price White Chrome S.Nickel H.Duty Finish 1 Year 1 Year Lifetime 9200 Inswing Warranty Painted Plated PVD Vinyl Swinging Door List Price White Chrome S.Nickel H.Duty Euro White Tan or Earthtone Black A.Brass Brass Argon 270 366 Rolling

More information

Vinyl Windows Manufactured by VPI Quality Windows

Vinyl Windows Manufactured by VPI Quality Windows Vinyl Windows Manufactured by VPI Quality Windows Part Number: 531&591 Installation 531 & 591 SERIES SLIDING AND HUNG WINDOW INSTALLATION INSTRUCTIONS Installation Instructions for Typical Construction.

More information

Window Parts and Styles

Window Parts and Styles CORE WEB BASED CORE APPLICATION SPECIFIC INSTALLATION INFORMATION AND METHODS Photo courtesy of Building-Products.com Window Parts and Styles Although all possible measures have been taken to insure the

More information

STRUCTURAL PERFORMANCE TEST REPORT

STRUCTURAL PERFORMANCE TEST REPORT Architectural Testing STRUCTURAL PERFORMANCE TEST REPORT TEST #31 Rendered to: COMMERCIAL DOOR SYSTEMS 320 Carner Drive Bensalem, Pennsylvania 19020 Report No: 01-39570.01 Test Date: 06/14/01 Report Date:

More information

ESR-2648 Reissued May 1, 2012 This report is subject to renewal June 1, 2013.

ESR-2648 Reissued May 1, 2012 This report is subject to renewal June 1, 2013. ICC-ES Evaluation Report ESR-2648 Reissued May 1, 2012 This report is subject to renewal June 1, 2013. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION:

More information

for Andersen 400 Series Woodwright Transom over 400 Series Woodwright Double-Hung or 400 Series Woodwright Picture Window

for Andersen 400 Series Woodwright Transom over 400 Series Woodwright Double-Hung or 400 Series Woodwright Picture Window for Andersen 400 Series Woodwright Transom over 400 Series Woodwright Double-Hung or 400 Series Woodwright Picture Window Congratulations! You have just purchased one of the many fine Andersen products.

More information

Series 9000 Vinyl Single Hung

Series 9000 Vinyl Single Hung Series 9000 Single Hung Series 9000 Vinyl Single Hung Contents List of Architectural Drawings...9000SH - 3 Elevations - Single Hung...9000SH - 4 Available Sizes - Single Hung...9000SH - 5 Elevations -

More information

SECTION BULLET- RESISTANT DOORS

SECTION BULLET- RESISTANT DOORS 1 SECTION 08 3950 BULLET- RESISTANT DOORS PART 1- GENERAL 1.01 SUMMARY A. This Section Includes: 1. Bullet- resistant steel door and frame systems. 2. Door hardware for bullet- resistant steel door and

More information

Transom Joining. for Andersen Elliptical Windows over Perma-Shield Gliding Patio Door

Transom Joining. for Andersen Elliptical Windows over Perma-Shield Gliding Patio Door Transom Joining for Andersen Elliptical Windows over Perma-Shield Gliding Patio Door INSTALLER: Please leave this guide with the building owner to file for future reference. Congratulations! You have just

More information

SECTION MANUFACTURED CASEWORK

SECTION MANUFACTURED CASEWORK 1 GENERAL 1.1 SECTION INCLUDES SECTION 12300 MANUFACTURED CASEWORK A. Work required to complete the manufactured casework indicated by the Contract Documents, and the items necessary for its proper installation.

More information

2.9 WINDOW & DOOR BUCKS

2.9 WINDOW & DOOR BUCKS 2.9 WINDOW & DOOR BUCKS Bucks provide attachment surfaces for windows and doors while holding back concrete from these openings during concrete placement. Mark the center and edges of openings as you place

More information

Series 9000 Vinyl Fixed Window

Series 9000 Vinyl Fixed Window Series 2030 Picture Window Series 9000 Vinyl Fixed Window Contents List of Architectural Drawings... 9000PW - 3 Elevations - 9000 Fixed... 9000PW - 4 Available Sizes - 9000 Fixed... 9000PW - 5 Elevations,

More information

Heavy Wall Applied Stop Tube Frame and Door Installation

Heavy Wall Applied Stop Tube Frame and Door Installation INSTALLATION INSTRUCTIONS Heavy Wall Applied Stop Tube Frame and Door Installation Read all instructions before beginning installation. These instructions are provided to help prevent installation problems

More information

AAMA Voluntary Guideline For Engineering Analysis of Window and Sliding Glass Door Anchorage Systems

AAMA Voluntary Guideline For Engineering Analysis of Window and Sliding Glass Door Anchorage Systems A M E R I C A N A R C H I T E C T U R A L AAMA 2501-06 Voluntary Guideline For Engineering Analysis of Window and Sliding Glass Door Anchorage Systems M A N U F A C T U R E R S A S S O C I A T I O N TABLE

More information

Installation Guide for Andersen 400 Series Tilt-Wash Transom Windows with Stormwatch Protection (PG Upgrade) Manufactured After 2006

Installation Guide for Andersen 400 Series Tilt-Wash Transom Windows with Stormwatch Protection (PG Upgrade) Manufactured After 2006 for Andersen 400 Series Tilt-Wash Transom Windows with Stormwatch Protection (PG Upgrade) Manufactured After 2006 Thank you for choosing Andersen. Instructions are for typical, new wood-framed wall construction

More information

Sun Windows General Information New Construction Hinged Door Installation Instructions

Sun Windows General Information New Construction Hinged Door Installation Instructions A G H F H H A. Apply Weather Resistive Barrier B. Apply Bottom Flashing Tape C. Install Sill Pan End Caps & Pan D. Caulk Sides & Top Nailing Surface, Set Door, Fasten E. Apply Side Flashing Tape F. Apply

More information

VINYL REPLACEMENT WINDOW INSTALLATION STANDARDS

VINYL REPLACEMENT WINDOW INSTALLATION STANDARDS VINYL REPLACEMENT WINDOW INSTALLATION STANDARDS BEFORE you start to remove the existing windows Place clean drop cloths in all work areas. Re-measure the opening to ensure the new window will fit. Remove

More information

TOLERANCES AND CLEARANCES FOR COMMERCIAL HOLLOW METAL DOORS AND FRAMES

TOLERANCES AND CLEARANCES FOR COMMERCIAL HOLLOW METAL DOORS AND FRAMES HOLLOW METAL MANUAL AMERICAN NATIONAL STANDARDS ANSI/ NAAMM HMMA-841 13 ANSI/NAAMM HMMA 841-13 METAL DOORS & FRAMES November 21, 2013 8d TOLERANCES AND CLEARANCES FOR COMMERCIAL HOLLOW METAL DOORS AND

More information

GLENWOOD 510 C Horizontal Slider

GLENWOOD 510 C Horizontal Slider TESTED FOR Date : October 28, 1998 FLEETWOOD ALUMINUM PRODUCTS, Inc. Page : 1 of 5 2485 Railroad Street Corona, CA 91720 1.0 PURPOSE The purpose of this report is to present the testing methods employed

More information

Mulling & Transom General Installation Instructions

Mulling & Transom General Installation Instructions 1. Overview: This document outlines general recommended instructions for combining Fleetwood s window and door products in the field. Additional detailed information on mulling and transoms is also available

More information

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY PERFORMANCE TEST REPORT Rendered to: GLASSCRAFT DOOR COMPANY SERIES/MODEL: Buffalo Forge Steel Doors / Arch Top Double PRODUCT TYPE: In-swing Arch Top Double Door RH-4-5/8 Title Uniform Load Deflection

More information

Sash Replacement Guide for Andersen Impact Resistant Casement Windows

Sash Replacement Guide for Andersen Impact Resistant Casement Windows Replacement Guide Replacement Guide for Andersen Impact Resistant Casement Windows Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation and maintenance

More information

PRODUCT DESCRIPTION. This evaluation report includes aluminum clad wood skylights based on the following tested configurations:

PRODUCT DESCRIPTION. This evaluation report includes aluminum clad wood skylights based on the following tested configurations: TEXAS DEPARTMENT OF INSURANCE Engineering Services Program / MC 10-A Guadalupe Street P.O. Box 149104 Austin, Texas 78714-9104 Phone No. (512) 22-2212 Fax No. (512) 46-669 PRODUCT EVALUATION Effective

More information

1-Way Vertical Joining (Pages 2-22) 1-Way Horizontal Joining (Pages 23-44)

1-Way Vertical Joining (Pages 2-22) 1-Way Horizontal Joining (Pages 23-44) 3/4" LVL Reinforced Joining Guide (1-Way Vertical Joining) or (1-Way Horizontal Joining) 3/4" LVL Reinforced Joining Guide (1-Way Vertical Joining) or (1-Way Horizontal Joining) for Andersen 400 Series

More information

INTRODUCING NEW SIZES FOR MARVIN DOORS

INTRODUCING NEW SIZES FOR MARVIN DOORS INTRODUCING NEW SIZES FOR MARVIN DOORS 12 REASONS WHY MARVIN DOORS ARE A SUPERIOR VALUE 1. NEW SIZES PERFECT FOR REMODELING AND REPLACEMENT. With 27 new sizes perfect for remodeling and replacement projects,

More information

Frenchwood Gliding Patio Doors

Frenchwood Gliding Patio Doors Frenchwood 400 Frenchwood Naturally occurring variations in grain, color and texture make each wood door panel one-ofa-kind. These defining features create a character unattainable in vinyl, steel or aluminum

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Thermally Broken Framing and Door Installation SL-450TB (2" x 4-1/2" with 1" Glazing) & SL-600TB (2" x 6" with 1" Glazing) IMPORTANT: Read all instructions before beginning installation.

More information

Thermally Broken Framing and Door Installation

Thermally Broken Framing and Door Installation INSTALLATION INSTRUCTIONS Thermally Broken Framing and Door Installation IMPORTANT: Read all instructions before beginning installation. These instructions are provided to help prevent installation problems

More information

SECTION WOOD DOORS

SECTION WOOD DOORS SECTION 08211 WOOD DOORS Notice to Vendors: CANV prefers to purchase products that contain tropical wood only if they are certified according to the guidelines of the Forest Stewardship Council (FSC).

More information

SECTION SWINGING AUTOMATIC ENTRANCES IN-GROUND, AUTOMATIC SWING DOOR OPERATOR CONVERTER ADAPTED TO BROOKFIELD NB-500 EXTREME DUTY OPERATOR

SECTION SWINGING AUTOMATIC ENTRANCES IN-GROUND, AUTOMATIC SWING DOOR OPERATOR CONVERTER ADAPTED TO BROOKFIELD NB-500 EXTREME DUTY OPERATOR SECTION 084229.33 SWINGING AUTOMATIC ENTRANCES IN-GROUND, AUTOMATIC SWING DOOR OPERATOR CONVERTER ADAPTED TO BROOKFIELD NB-500 EXTREME DUTY OPERATOR PART 1-GENERAL 1.01 DESCRIPTION A. This section describes

More information

Pre-Hung Entry Door Systems

Pre-Hung Entry Door Systems Pre-Hung Entry Door Systems AC101_Achiever_Residential_10.13_Layout 1 10/23/13 4:10 PM Page 2 For over Fifty Years DUNBARTON Door and Entry Systems has been an innovative influence in the industry by pushing

More information

ICC-ES Evaluation Report Reissued June 1, 2010 This report is subject to re-examination in one year.

ICC-ES Evaluation Report Reissued June 1, 2010 This report is subject to re-examination in one year. ICC-ES Evaluation Report ESR-2648 Reissued June 1, 2010 This report is subject to re-examination in one year. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council

More information

SERIES 5001 SLIDING GLASS DOOR PATIO DOORS INSTALLATION GUIDE

SERIES 5001 SLIDING GLASS DOOR PATIO DOORS INSTALLATION GUIDE PATIO DOORS INSTALLATION GUIDE These instructions cover general installation conditions. Improper installation could affect your doors operation and warranty. Deviations from these instructions should

More information

3/4" LVL Reinforced Joining Guide

3/4 LVL Reinforced Joining Guide (2-Way Horizontal and Vertical Joining) for Andersen 400 Series Tilt-Wash Double-Hung, Picture, and Transom Windows with Stormwatch Protection Congratulations! You have just purchased one of the many fine

More information

SECTION HOLLOW METAL DOORS AND FRAMES

SECTION HOLLOW METAL DOORS AND FRAMES SECTION 081113 HOLLOW METAL DOORS AND FRAMES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Standard hollow metal doors and frames. 1.2 SUBMITTALS A. Product Data: Include construction details, material

More information

ASTM E1886 and ASTM E1996 TEST REPORT. Rendered to: FLEETWOOD WINDOWS AND DOORS Corona, California

ASTM E1886 and ASTM E1996 TEST REPORT. Rendered to: FLEETWOOD WINDOWS AND DOORS Corona, California This report contains in its entirety: Cover Page: 1 page Report Body: 11 pages Sketch: 1 page Drawings: 5 pages ASTM E1886 and ASTM E1996 TEST REPORT Report No.: E8384.02-301-18 Rendered to: FLEETWOOD

More information

40mm Thermoclick. Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial)

40mm Thermoclick.  Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial) http://www.sundancesupply.com 40mm Thermoclick Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial) U-Profile 12' Lengths $39 Out System offers a complete set of extrusions and accessories

More information

ASTM E1886 and ASTM E1996 TEST REPORT. Rendered to: FLEETWOOD WINDOWS AND DOORS Corona, California

ASTM E1886 and ASTM E1996 TEST REPORT. Rendered to: FLEETWOOD WINDOWS AND DOORS Corona, California This report contains in its entirety: Cover Page: 1 page Report Body: 11 pages Sketch: 1 page Drawings: 12 pages ASTM E1886 and ASTM E1996 TEST REPORT Report No.: E8390.02-301-18 Rendered to: FLEETWOOD

More information

Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement

Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement 1 Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement The following instructions are a supplement

More information

Model GT 2300 ICU Manual Swing Door Unequal Panels - Smoke Rated

Model GT 2300 ICU Manual Swing Door Unequal Panels - Smoke Rated S82 W18717 Gemini Drive Muskego, Wisconsin 53150 Phone: (877) 622-2694 Fax: (888) 679-3319 www.nabcoentrances.com Technical Support: (866) 622-8325 Model GT 2300 ICU Manual Swing Door Unequal Panels -

More information

Design Considera ons & Installa on Guidance

Design Considera ons & Installa on Guidance Design Considera ons & Installa on Guidance LiteSpace Interior Aluminum Framing provides a slim profile for glass walls and office fronts. It is designed to be cut to length on project sites for finished,

More information

Series 7600 Installation Instructions Aluminum Multi-Slide Door (Pocketing)

Series 7600 Installation Instructions Aluminum Multi-Slide Door (Pocketing) Series 7600 Installation Instructions Aluminum Multi-Slide Door (Pocketing) Things to Know Before You Start Things to Know Before You Start Removal of Old Fenestration Products Ensure any old fenestration

More information

VINYL-COMPOSITE SWING DOOR SYSTEMS

VINYL-COMPOSITE SWING DOOR SYSTEMS VINYL-COMPOSITE SWING DOOR SYSTEMS SERIES SI4000V Versatile entrances for any application. Solar Innovations now offers a line of upvc Vinyl-Composite Swing Doors. These doors are perfect for both commercial

More information

ENTRY DOOR TEST REPORT. Rendered to: The Vistawall Group

ENTRY DOOR TEST REPORT. Rendered to: The Vistawall Group ENTRY DOOR TEST REPORT Rendered to: The Vistawall Group Product: Single 500 Wide Stile Outswing Full-Lite Aluminum Entry Door w/ Standard TH-43 Threshold and Woolpile Weathering Title Air Infiltration@

More information

Imagine a front entrance that is distinctively yours. Upstate Door will work with

Imagine a front entrance that is distinctively yours. Upstate Door will work with --The look of a fine door says many things in subtle ways...class, elegance, and luxury. Imagine a front entrance that is distinctively yours. Upstate Door will work with you to create a front entrance

More information

Architectural Information Series 614 ClearVENT Double-hung Window Design Features Australian registered design

Architectural Information Series 614 ClearVENT Double-hung Window Design Features   Australian registered design Architectural Information Page: 27. 1 Introduction Design Features This full vision vertical sliding sashless double-hung window has been designed to complement our existing quality product range including:

More information

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1. PAGE 1 PART 1 GENERAL 1.1 REFERENCE.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1. 1.2 RELATED WORK SPECIFIED ELSEWHERE.1 Installation

More information

Series 9000 Vinyl Fixed Window

Series 9000 Vinyl Fixed Window Series 2030 Picture Window Series 9000 Vinyl Fixed Window Contents List of Architectural Drawings... 9000PW - 3 Elevations - 9000 Fixed... 9000PW - 4 Available Sizes - 9000 Fixed... 9000PW - 5 Elevations,

More information

Vinyl Windows and Doors Manufactured by VPI Quality Windows

Vinyl Windows and Doors Manufactured by VPI Quality Windows Vinyl Windows and Doors Manufactured by VPI Quality Windows Part Number: 511_Installation ENDURANCE CASEMENT\AWNING\PW INSTALLATION INSTRUCTIONS Installation Instructions for Typical Construction These

More information

Installation Guide for Andersen 400 Series Gliding Windows

Installation Guide for Andersen 400 Series Gliding Windows for Andersen 400 Series Gliding Windows Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation and maintenance are essential if the benefits of your

More information

SECTION SWINGING AUTOMATIC ENTRANCES

SECTION SWINGING AUTOMATIC ENTRANCES SECTION 084229.33 SWINGING AUTOMATIC ENTRANCES IN-GROUND, AUTOMATIC SWING DOOR OPERATOR CONVERTER ADAPTED TO IR/DOR-O-MATIC SENIOR SWING & ASTRO SWING OPERATOR PART 1-GENERAL 1.01 DESCRIPTION A. This section

More information

General Information... Elevation Notes... Elevation Notes Transom... Light Cut Information... Clear Opening Design Data Table 1 & 2 Panel...

General Information... Elevation Notes... Elevation Notes Transom... Light Cut Information... Clear Opening Design Data Table 1 & 2 Panel... TABLE OF CONTENTS General Information..................................... Elevation Notes......................................... Elevation Notes Transom................................. Light Cut Information....................................

More information

INSTALLATION INSTRUCTIONS - INSTRUCCIONES DE INSTALACION FOR HURRICANESHIELD IMPACT-RESISTANT DOUBLE-HUNG, SINGLE-HUNG AND SIMULATED-HUNG

INSTALLATION INSTRUCTIONS - INSTRUCCIONES DE INSTALACION FOR HURRICANESHIELD IMPACT-RESISTANT DOUBLE-HUNG, SINGLE-HUNG AND SIMULATED-HUNG 2008 Pella Corporation Part Number: 80ED0101 INSTALLATION INSTRUCTIONS - INSTRUCCIONES DE INSTALACION FOR HURRICANESHIELD IMPACT-RESISTANT DOUBLE-HUNG, SINGLE-HUNG AND SIMULATED-HUNG Instrucciones en español

More information

FOLDING GLASS WALL SYSTEMS

FOLDING GLASS WALL SYSTEMS FOLDING GLASS WALL SYSTEMS SERIES SI3000 A seamless wall with endless possibilities. Series SI3000 Aluminum Folding Glass Wall Systems have been a signature product of Solar Innovations since their introduction

More information

SCI-FAB Product Specifications. Casework Section 1. Part 1 General

SCI-FAB Product Specifications. Casework Section 1. Part 1 General SCI-FAB Product Specifications Casework Section 1 Part 1 General 1.1 SCOPE OF WORK Includes all factory fabricated stainless steel casework as required by the project drawings. 1.2 TYPICAL INCLUSIONS A.

More information

Horse Shelter 12 x

Horse Shelter 12 x Horse Shelter 12 x 15 76110678 Hardware Kit 76900228 THANK YOU FOR PURCHASING THIS PRODUCT Behlen Country has been in the business of providing quality products for more than 75 years. Our products will

More information

EURO (3876) Euro-C2 Installation Instructions Euro-Wall Systems, LLC

EURO (3876)   Euro-C2 Installation Instructions Euro-Wall Systems, LLC 888.989.EURO (3876) www.euro-wall.com Euro-C2 Installation Instructions Installation Instructions Euro-C2 step A.1) Assemble Bottom corner Pre-caution: it is recommended to use screw wax to prevent screw

More information

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows americancraftsmanwindows.com Project Requirements: Read

More information

ASTM E 283, ASTM E 547, AND ASTM E 330 TEST REPORT. Rendered to: SIMPSON DOOR COMPANY

ASTM E 283, ASTM E 547, AND ASTM E 330 TEST REPORT. Rendered to: SIMPSON DOOR COMPANY ASTM E 283, ASTM E 547, AND TEST REPORT Rendered to: SIMPSON DOOR COMPANY SERIES/MODEL: Simpson Door Fir 1501 PRODUCT TYPE: Wood Inswing Door with Side Lites Report No: Test Date: 04/02/04 Report Date:

More information

B. Terracotta Precast Facade Assembly consisting of single-leaf, through body color terracotta clay tiles.

B. Terracotta Precast Facade Assembly consisting of single-leaf, through body color terracotta clay tiles. SECTION 07 4229 TERRACOTTA CLAY TILE IN PRECAST SPECIFICTION FOR TERRART SOLID PART 1 GENERAL 1.1 SECTION INCLUDES A. Drawings and general provisions of the Contract, including General and Supplementary

More information

Testing. Material testing will be according to applicable AASHTO, ASTM or Department methods as specified.

Testing. Material testing will be according to applicable AASHTO, ASTM or Department methods as specified. 907.01 Section 907. FENCING MATERIALS 907.01 General Requirements. Materials for use in fencing property, right-of-way and other installations must comply with this section. 907.02 Testing. Material testing

More information

Engineering Services Program

Engineering Services Program GDR41 1214 Product Evaluation Engineering Services Program The following product has been evaluated for compliance with the wind loads specified in the International Residential Code (IRC) and the International

More information