1 Fieldbus Solutions & Network Topologies ISA Exhibition Toronto May 12, 2004

2 Fieldbus Solutions During this presentation we will talk about different network topologies and Fieldbus solutions for different applications. We will discuss the latest Fieldbus solutions for intrinsically safe, non-incendive and general purpose applications. Agenda With the recent increase in Fieldbus applications this short tutorial will highlight the wide range of solutions available to an Engineer installing a Fieldbus system.

3 Fieldbus Solutions Different Fieldbus applications require different solutions! Fieldbus Solutions General Purpose (no power limitations) Intrinsic safety (limited energy) - Non-incendive (Class I, Div.2) - Entity (Class I, Div.1) - FISCO (Class I, Div.1) Mixed applications

4 General Purpose Non-Incendive Intrinsically Safe Mixed Applications AGENDA Summary

5 General Purpose Control Room No power restrictions, products range from 350 ma to 1 Amp per segment Typically field devices/h1 segment Fieldbus Solutions es to connect devices to a trunk (no daisy chained connections) Power Repeaters are possible for longer cable runs and isolation Each segment must be terminated at both ends

6 General Purpose Red. Power Supply Active Active Active Control Room Higher level of security/availability! High power red. Power supply Fieldbus Solutions Short circuit protected, active junction boxes with built in selectable terminators A single short will not bring down an entire segment!

7

8 General Purpose Non-Incendive Intrinsically Safe AGENDA Mixed Applications Summary

9 Control Room Non-Incendive NI PS Class I, Div.2 NI PS NI PS More centralized architecture in this example Fieldbus Solutions Energy limited non-incendive trunk and spurs Simplifies wiring for Class I, Div.2 applications (no conduit) Can be used with NI, IS or FISCO field devices

10 Control Room Non-Incendive Class I, Div.2 Div.2 wiring method Redundant Power Hub Nonincendive outputs High Power Trunk with energy limited non-incendive spurs Fieldbus Solutions Taking true advantage of Fieldbus technology by using a distributed architecture Doesn t use up expensive control room real estate

11 Control Room Segment Protectors Segment Protectors, DIN-Rail mountable Power Supply Custom Field Enclosure Div.2 wiring method for trunk Nonincendive outputs Class I, Div.2

12 FNICO Fieldbus Non-Incendive ncendive COncept Based on FISCO with reduced factor of safety Reduced factor of safety allows more current into the Div.2 hazardous location (up to 215 ma available for up to 10 devices) FNICO is a non-incendive technique for Division 2 hazardous areas Simplified Div.2 wiring (no conduit etc.) when used with IS or FISCO field devices Live maintenance no hot work permit, just like Intrinsic Safety

13 FNICO Some Division 2 Definitions Non-arcing circuit: - may contain incendive levels of voltage and current - NOT live-workable - cables must be mechanically protected Non-incendive circuit - energy-limited to lower levels of voltage and current - like IS, but without fault counting and with lower safety factor - LIVE-workable under power When using FNICO power supplies, the trunk and spurs are non-incendive FNICO cable parameters are the same as for FISCO, spur length is 60m

14 Div.2 Mountable vs. Nonincendive Outputs Many devices are Div.2 mountable BUT not all Div. 2 mountable devices have nonincendive rated (energy limited) outputs! Check the marking on the product to make sure the outputs are energy limited and rated nonincendive Only nonincendive outputs are live workable!

15 General Purpose Non-Incendive Intrinsically Safe Mixed Applications Summary

16 Control Room Intrinsic Safety Class I, Div.1 Class I, Div.2 Energy Limited Intrinsically Safe Trunk and spurs Using the FISCO model: up to 6 devices on 1 power repeater vs. 4 for Entity Using n power repeaters n x 6 field devices Installable in Div. 2 to gain cable length

17 Intrinsic Safety Field Barrier Class I, Div.2 Field Barrier Control Room Class I, Div.1 Fieldbus Solutions Latest technology => Field barrier No power limitation for Trunk (non-is) True distributed architecture Combines the features of: - active junction box - with an IS barrier All in a field mountable package

18 Control Room FieldBarrier FieldBarriers, DIN-Rail mountable Power Supply Custom Field Enclosure Div.2 wiring method for trunk IS outputs (Zone 1,0 Class I, Div.1 A-D) Class I, Div.1 Zone 0

19 FIELDBUS INTRINSICALLY SAFE CONCEPT FISCO is in accordance with intrinsic safety world standards (Intrinsic safety according to EN50020 and IEC 79-11, Class I, Division 1 according to US-standards) Only one active source (power supply) per system The nodes act as passive current sinks Nodes have negligible internal inductance and capacitance (Li 10μH, Ci 5nF) Variety of cables with specified parameters can be used Max. cable length is 1000 m (3281 ft) Bus line is terminated at both ends Field devices and power source have to be in accordance with FISCO.

20 FISCO Model If you reach the previous preconditions the verification of intrinsic safety will be reduced to: Power Repeater Field device V 0C < U i I SC < I i P 0 < P i

21 Add all C i, L i of instruments Add cable L cable, C cable Compare all V max, I max of instruments and evaluate to parameters of power source Evaluate: V oc < V max I sc < I max (individually) P 0 < P i (individually) C a > C i + C cable L a > L i + L cable Entity Concept Difficult to do for fieldbus network! Very time consuming! FISCO is more user friendly!

22

23 General Purpose Non-Incendive Intrinsically Safe AGENDA Mixed Applications Summary

24 Control Room Mixed Applications Red. Power Supply Safe Area Active Fieldbus Solutions Field Barrier Class I, Div.1 Active Class I, Div.2

25 Mixed Applications IS and non-is segments can easily be mixed when using the proper interface devices Trunk cable runs can be longer and more secure when using a high reliable, redundant Fieldbus power supply IS protection (FISCO or Entity based) can be achieved when and where ever needed by using Field barriers or IS power repeaters/isolated power supplies in the field and close to the field instruments Fieldbus Solutions

26 General Purpose Non-Incendive Intrinsically Safe AGENDA Mixed Applications Summary

27 Summary/Questions Fieldbus Solutions Many different topologies are possible. In order to find the best solution it is important to determine: Is it a general purpose, IS, NI or mixed application? => It might be advantages to bring high power, red. Trunk into the field and use devices like field barriers or isolators to create IS protection where needed. Do I prefer a true distributed architecture? => limited control room space, field mountable interface devices! Do I have critical loops? => Redundant PS, short circuit protected junction boxes, higher availability

28 Thank you! Fieldbus Solutions

White Paper. Requirements for fieldbus equipment installed in a Zone 2 and Division 2 hazardous area environment. March 24, 2005

White Paper. Requirements for fieldbus equipment installed in a Zone 2 and Division 2 hazardous area environment. March 24, 2005 White Paper Requirements for fieldbus equipment installed in a Zone 2 and Division 2 hazardous area environment March 24, 2005 up Königsberger Allee 87 68307 Mannheim Germany Tel. + 49 621 776-0 Fax +49

More information

CERTIFICATE OF COMPLIANCE

CERTIFICATE OF COMPLIANCE FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 0202 USA T: 781 72 400 F: 781-72-975 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL EQUIPMENT

More information

COMMUNICATION NETWORKS

COMMUNICATION NETWORKS Zone Applications (PROFIBU PA) MB eptember 2008 COMMUNICATION NETWORK FOR ZONE APPLICATION (PROFIBU PA) Michael Bean - 8 eptember 2008 INTRODUCTION: In recent years it has become increasingly popular to

More information

Thie. Automation Products Rev. Chang Date Name Supersedes Dwg. : Part Class:

Thie. Automation Products Rev. Chang Date Name Supersedes Dwg. : Part Class: Page: 1 of 3 - - 2003 Date Name Name 27.03.03 Thiem. Title FM/CSA-Control-Document Appr. / 5 08.07.11 Thie. Std. 4 07.10.09 Lasa. 3 26.06.06 Thie. Drwg.-No. (Part-No.) 2 22.05.06 Thie. 901265 1 27.03.

More information

Foundation Fieldbus Topologies for Intrinsically Safe (IS) Installations

Foundation Fieldbus Topologies for Intrinsically Safe (IS) Installations Foundation Fieldbus Topologies for Intrinsically Safe (IS) Installations Dr.-Ing. Gunther Kegel CEO Pepperl+Fuchs GmbH, Mannheim Member of the Fieldbus Foundation Board of Directors Chairman of the FF

More information

FM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

FM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers Instruction Manual Supplement DVC6200 Digital Valve Controllers FM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers SIS Hazardous Area Approvals and Special Instructions

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 3/06 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature

More information

megablock series passive hubs for fieldbus networks

megablock series passive hubs for fieldbus networks passive hubs for fieldbus networks Relcom megablock series Megablocks are DIN-rail mounted passive hubs for Foundation fieldbus networks. They connect several field devices to the network trunk cable and

More information

Intrinsic Safety Control Drawing

Intrinsic Safety Control Drawing s Intrinsic Safety Control Drawing A5E00455287 system in total "No revision to drawing without prior Approval by FM Approvals!" PLC PC Non hazardous area PROFIBUS DP RS 485-IS Coupler PROFIBUS RS 485-IS

More information

DART THE FUTURE OF EXPLOSION PROTECTION TECHNOLOGY

DART THE FUTURE OF EXPLOSION PROTECTION TECHNOLOGY DART THE FUTURE OF EXPLOSION PROTECTION TECHNOLOGY T. Klatt Pepperl-Fuchs, Mannheim, Germany In the process industry, it is possible for potentially explosive gases to escape in the event of a fault, which

More information

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift Appendix A Specifications 1797-IE8 and -IE8NF Input Modules Specifications Number of Inputs IS Input Type IS Module Type Resolution Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift Functional

More information

JM Enclosure Dimensions (in mm)

JM Enclosure Dimensions (in mm) ub #0revB process networking solutions Junction Module (JM ) Enclosure with: FOUNDATION Fieldbus Input/Output Module (JMM9 ) These I/O Modules are designed to function as FOUNDATION Fieldbus nodes with

More information

technical datasheet technical datasheet Megablock Series passive hubs for fieldbus networks

technical datasheet technical datasheet Megablock Series passive hubs for fieldbus networks technical datasheet technical datasheet Megablock Series passive hubs for fieldbus networks Megablocks are DIN-rail mounted passive hubs for FOUNDATION fieldbus networks. They connect several field devices

More information

Title: INTRINSIC SAFETY MADE EASY

Title: INTRINSIC SAFETY MADE EASY Title: INTRINSIC SAFETY MADE EASY By: TH Kuan KL Automation Engineering Sdn. Bhd. ICA 2006 Date: 19.02.2006 Profile of Kuan Teik Hua Mr. Kuan is a Director for KL Automation Engineering Sdn Bhd. He has

More information

IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers Instruction Manual Supplement DVC6200 Digital Valve Controllers IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers SIS Hazardous Area Approvals and Special Instructions

More information

Fieldbus Foundation India Committee & ISA South India Section

Fieldbus Foundation India Committee & ISA South India Section Fieldbus Foundation India Committee & ISA South India Section Fieldbus Foundation FFIC + ISA Fieldbus Foundation Conference-2010 Date Time Venue :6 th February, 2010 ( Saturday) : from 09:00 am to 05:30

More information

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers Instruction Manual Supplement DVC6005 Digital Valve Controllers CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers Hazardous Area Approvals and Special Instructions

More information

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers Instruction Manual Supplement DVC6200 Digital Valve Controllers CSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers SIS Hazardous Area Approvals and Special Instructions

More information

TÜV NORD CERT. TÜV NORD CERT GmbH & Co. KG Am TÜV 1 D Hannover. Annexe to IECEx TUN , issue No. 0 Page 1 of 5.

TÜV NORD CERT. TÜV NORD CERT GmbH & Co. KG Am TÜV 1 D Hannover. Annexe to IECEx TUN , issue No. 0 Page 1 of 5. GmbH & Co. KG Page 1 of 5 Electrical data: Base devices for 6DR50**-*****-**** Motherboard L250 Power supply / control current 4-20 ma... series connection (terminals 6+ and 7/8) 2-wire circuit with Hart

More information

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/ > 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

PROCESS AUTOMATION MANUAL FIELDBARRIER

PROCESS AUTOMATION MANUAL FIELDBARRIER PROCESS AUTOMATION MANUAL FIELDBARRIER SCHULUNG V2 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services

More information

F2xx & F2xx-XE Megablock Series

F2xx & F2xx-XE Megablock Series technical datasheet technical datasheet Fxx & Fxx-XE Megablock Series passive hubs for Zone & Division fieldbus networks Megablocks are DIN-rail mounted passive hubs for Foundation fieldbus networks. They

More information

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22 www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

Head mounted Temperature Transmitter TF02/TF02-Ex

Head mounted Temperature Transmitter TF02/TF02-Ex Data Sheet Head mounted Temperature Transmitter TF0/TF0-Ex FOUNDATION Fieldbus H, Pt 00 (RTD), thermocouples, or independent channels Input Resistance thermometer (-, -, -wire circuit) Thermocouples Resistance

More information

STT 3000 Smart Temperature Transmitter Series STT170 Specifications

STT 3000 Smart Temperature Transmitter Series STT170 Specifications STT 3000 Smart Temperature Transmitter Series STT170 Specifications Model STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 November 2010 Overview STT17H Features The Honeywell STT170 series of programmable

More information

INTRINSICALLY SAFE DUPLEXER

INTRINSICALLY SAFE DUPLEXER INTRINSICALLY SAFE DUPLEXER MADE IN THE U.S.A. DESCRIPTION The Intrinsically Safe Duplexer, ISD, is a low cost SCADA ready intrinsically safe pump controller designed to perform level control for duplex

More information

F2xx & F2xx-XE megablock range

F2xx & F2xx-XE megablock range Technical data MTL fieldbus networks September 0 EPS Fxx rev Fxx & Fxx-XE megablock range Passive hubs for zone & division fieldbus networks Megablocks are DIN-rail mounted passive hubs for Foundation

More information

General Specifications

General Specifications General Specifications GS 01F06F01-01EN Model DY Vortex Flowmeter Model DYA Vortex Flow Converter FOUNDATION Fieldbus Communication Type General FOUNDATION Fieldbus is the digital communication line for

More information

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels TF 0 / TF 0-Ex Head mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.5 EN Input Resistance thermometer (,, wire circuit) Thermocouples

More information

Mass and Volume Flow Transmitter

Mass and Volume Flow Transmitter IFT9701 Product Data Sheet PS-00218-EU December1999 Mass and Volume Flow Transmitter IFT9701 transmitter The IFT9701 microprocessor-based transmitter works with Micro Motion sensors to provide affordable,

More information

MCR-FL-TS-LP-I-EX SIL IEC Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol

MCR-FL-TS-LP-I-EX SIL IEC Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol SIL IEC 6 508 Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol Data Sheet 0068_en_03 PHOENIX CONTACT 0-07-09 Description Temperature FL ϑ Universal PC programmable

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

EJX and EJA-E Series Differential Pressure and Pressure Transmitters Installation Manual. Contents 1. Introduction. 3. Installation. 5.

EJX and EJA-E Series Differential Pressure and Pressure Transmitters Installation Manual. Contents 1. Introduction. 3. Installation. 5. User s Manual EJX and EJA-E Series Differential Pressure and Pressure s Installation Manual Contents 1. Introduction 1.1 For Safe Use of Product...2 1.2 Warranty...3 1.3 ATEX Documentation...4 2. Handling

More information

Loop Powered Indicator

Loop Powered Indicator Instruction Manual Model PD686 Loop Powered Indicator M397 January 3, 2019 JOWA USA, Inc. 59 Porter Road Littleton, MA 01460-1431 USA Tel: 978-486-9800 Fax: 978-486-0170 PD686 I.S. and N.I. NEMA 4X, IP67

More information

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5. Ex i Isolators Temperature Transmitter with Output 0/4... 20 ma, without Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe

More information

ATEX Installation Drawings and Instructions

ATEX Installation Drawings and Instructions Installation Instructions P/N 20004414, Rev. C September 2008 ATEX Installation Drawings and Instructions For ATEX-approved transmitter installations Note: For hazardous installations in Europe, refer

More information

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471 > 16 channels for active 0 / 24 V signals > Zone 2 / Division 2 version for connection of circuits acc. to Ex nl, Ex na, Nonincendive and Non-Ex > Galvanic separation between inputs and system > Two channels

More information

Industrial Pressure Transducers

Industrial Pressure Transducers Industrial Pressure Transducers User s Manual T Model T Model The Swagelok T model transducer is engineered for use in industrial pressure measurement applications where intrinsically safe ratings are

More information

FLEX Ex Power Supplies

FLEX Ex Power Supplies Installation Instructions FLEX Ex Power Supplies (Cat. Nos. 1797-PS2N, -PS2E) About the Power Supplies The power supply is an essential component in the operation of an intrinsically safe system. It must

More information

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i Temperature Transmitter Series 9182 www.stahl.de > One unit for nearly all temperature sensors indivdually configurable > Intrinsically safe input [Ex ia] IIC > Signal duplication possible > Galvanic isolation

More information

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily

More information

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/. Ex i Isolators Temperature Transmitter without Output 0/4... 20 ma, with Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe

More information

DPharp Differential Pressure and Pressure Transmitters

DPharp Differential Pressure and Pressure Transmitters User s Manual DPharp Differential Pressure and Pressure s Manual Change No. 12-021-2 For the products of EJX and EJA-E series with any of the following option codes, please refer to this manual change

More information

Power supply. Calibration. Surface finishing. Seal. Process connection

Power supply. Calibration. Surface finishing. Seal. Process connection Page 1 of 6 Description The measuring system is designed for flow measurement. Gas flow through the sensing section passes two PT 100 RTD transducers; one is used as a temperature sensing device whilst

More information

FM Control Drawing Class I Division 2 / Class I Zone 2. Compact version PROMAG 10

FM Control Drawing Class I Division 2 / Class I Zone 2. Compact version PROMAG 10 Hazardous Locations Class I Div. 2 Groups ABCD or Class I Zone 2 Groups IIC and Class II and III Division 1 Groups EFG W / P / E / H / D / L Notes: 1. Control room equipment shall not use or generate more

More information

Description. Annexe to: IECEx CML X Issue 1. Isolating Amplifier D461

Description. Annexe to: IECEx CML X Issue 1. Isolating Amplifier D461 October 13, 2017 Annexe to: IECEx CML 15.0063X Issue 1 Applicant: Apparatus: Braun GmbH Isolating Amplifier D461 Description The Isolating Amplifier D461 is an intrinsic safety associated apparatus

More information

A local 3.5 mm network jack allows a convenient way to connect an installation or diagnostic tool to the network without disconnecting any wires.

A local 3.5 mm network jack allows a convenient way to connect an installation or diagnostic tool to the network without disconnecting any wires. FEATURES - Extends wiring distance of FTT-10 LonWorks Networks. - Up to 5 repeaters can be daisy chained together to create a multi-segment repeater of up to 10 channels. - Low cost alternative to routers

More information

PROline promag 53 Division 1

PROline promag 53 Division 1 XA 040D/06/en/05.01 50099923 FM+SGML 6.0 PROline promag 53 Division 1 Ex Ex documentation for the BA 053D and BA 054D operating instructions according to FACTORY MUTUAL standards documentation for the

More information

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12 EB-20023139 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page

More information

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model 3500 Transmitters

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model 3500 Transmitters Installation Instructions P/N MMI-20011707, Rev. AA July 2009 ATEX Installation Instructions for Micro Motion Model 3500 Transmitters Note: For hazardous installations in Europe, refer to standard EN 60079-14

More information

10 Mb/s Single Twisted Pair Ethernet Powering in an Intrinsically Safe System Steffen Graber Pepperl+Fuchs

10 Mb/s Single Twisted Pair Ethernet Powering in an Intrinsically Safe System Steffen Graber Pepperl+Fuchs 10 Mb/s Single Twisted Pair Ethernet Powering in an Intrinsically Safe System Steffen Graber Pepperl+Fuchs IEEE802.3 10 Mb/s Single Twisted Pair Ethernet Study Group 11/4/2016 1 Supporters David Brandt,

More information

8000 Series I/O Product Catalog

8000 Series I/O Product Catalog 8000 Series I/O Product Catalog 2 novatech Contents 8000 Series Overview...4 NT-8521-EB-NT, 8000 Series EBIM...8 System Specifications...10 Module Datasheets Analog Input Modules NT-8101-HI-TX, 8-channel

More information

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Interface DIN-Rail Models D1034S, D1034D D1034S - D1034D

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Interface DIN-Rail Models D1034S, D1034D D1034S - D1034D D034S D034D INSTRUCTION MANUAL SIL 3 Switch/Proximity Detector Interface DINRail Models D034S, D034D D034 SIL 3 Switch / Proximity Detector Interface ISM0053 SIL Applications For Safety Related System

More information

10 Mb/s Single Twisted Pair Ethernet Intrinsic Safety Proposal Steffen Graber Pepperl+Fuchs

10 Mb/s Single Twisted Pair Ethernet Intrinsic Safety Proposal Steffen Graber Pepperl+Fuchs 10 Mb/s Single Twisted Pair Ethernet Intrinsic Safety Proposal Steffen Graber Pepperl+Fuchs IEEE P802.3cg 10 Mb/s Single Twisted Pair Ethernet Task Force 3/7/2017 1 Content Intrinsically Safe 200 m Link

More information

Engineering Guideline. pac-carriers Type for Yokogawa Centum VP

Engineering Guideline. pac-carriers Type for Yokogawa Centum VP Engineering Guideline pac-carriers Type 9195 for Yokogawa Centum VP pac-carrier Type 9195 2 Engineering Guideline / Yokogawa Centum VP 26.0.2018 pac-carrier Type 9195 Integrated solutions for Yokogawa

More information

User s Manual. Manual Change No V-E. Please use the attached sheets for the pages listed below in IM 01F06F00-01EN (7th).

User s Manual. Manual Change No V-E. Please use the attached sheets for the pages listed below in IM 01F06F00-01EN (7th). User s Manual Model DY Vortex Flowmeter (Integral Type, Remote Type) Model DYA Vortex Flow Converter (Remote Type) FOUNDATION Fieldbus Communication Type Manual Change No.14-013V-E Please use the attached

More information

ControlNet Ex Modular Repeater Adapter & Fiber Repeater Module

ControlNet Ex Modular Repeater Adapter & Fiber Repeater Module 1 +V 2 -V 3 +V 4 -V Installation Instructions Modular Repeater Adapter & Fiber Repeater Module (Cat No 1797-RPA, -RPFM) indicators backplane connector cover 1797-RPA Do not remove unless connecting to

More information

SISNet Distance Extenders

SISNet Distance Extenders April 2011 Page 1 Extend the DeltaV SIS remote peer ring with Dedicated safety communications Full communications redundancy Flexibility to meets project needs Consistent update rate Introduction The DeltaV

More information

FLEX Ex System Certification

FLEX Ex System Certification FLEX Ex System Certification 1797 Series Reference Manual Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines

More information

Predictive Intelligence in Foundation Fieldbus

Predictive Intelligence in Foundation Fieldbus Predictive Intelligence in Foundation Fieldbus Binoy Kamath AGM Project Pursuit Pepperl+Fuchs India Pvt. LTd.,Bangalore Agenda Need For Predictive Intelligence What does FF Enable? Where to implement Predictive

More information

Temperature Input Module for Zone 1 Series 9482/32

Temperature Input Module for Zone 1 Series 9482/32 www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >

More information

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12 EB-20023137 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page

More information

INTRINSIC SAFETY BASIC PRINCIPLES

INTRINSIC SAFETY BASIC PRINCIPLES INTRINSIC SAFETY BASIC PRINCIPLES IGNITION TRIANGLE Ignition Energy In many industrial processes, the presence of flammable materials (gases, vapours, liquids, dusts, fibres and flyings) requires the adoption

More information

EN Series Installation Manual

EN Series Installation Manual Pub # 007revG EN Series Installation Manual Approval Agency Controlled Document. No Changes Authorized Without Prior Agency Approval StoneL 7 US Highway 9 Fergus Falls, MN 7 USA Telephone: (8) 79-77 Fax:

More information

Railbus isolator. Railbus isolator 8922-RB-IS

Railbus isolator. Railbus isolator 8922-RB-IS Railbus isolator Railbus isolator 8922-RB-IS provides galvanic isolation between Railbus sections prevents fault-voltage invasions protects IS field wiring modules See also System Specification Dimensions

More information

Annex 1 to Certificate of Conformity IECEx KEM X Issue No. 8 Rota Yokogawa Rotamass 3 Series Coriolis Mass Flowmeter

Annex 1 to Certificate of Conformity IECEx KEM X Issue No. 8 Rota Yokogawa Rotamass 3 Series Coriolis Mass Flowmeter Description RotaMass 3 Series Coriolis Mass Flow Meter; - Integral Transmitter, Model RCCx; - Remote Converter, Model RCCF31; - Remote Converter, Model RCCR31; - Remote Detector Model RCCS3xxxx The Coriolis

More information

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output. GENERAL INFORMATION T6000 SERIES TRANSDUCER Electro-Pneumatic (I/P, E/P) APPLICATIONS The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series Transmitter Supply Unit Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring and messaging for input

More information

Foundation Fieldbus Redundant Junction Box

Foundation Fieldbus Redundant Junction Box Quick Start Foundation Fieldbus Redundant Junction Box Catalog Number 1788-FBJB4R Topic Page About the Junction Box 1 Additional Resources 1 Installation 2 Configuration 3 Operation 3 Specifications 4

More information

Remote I/O. 74 Remote I/O. Remote I/O System

Remote I/O. 74 Remote I/O. Remote I/O System System Overview of the System Components IS1+ 76 General Information IS1+ 77 CPU & Power Modules CPU & Power Modules for Zone 1 / Div. 1 IS1+ 9440/22 78 Sockets for CPU & Power Module IS1+ 9490 78 CPU

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70163240 (166720) Issued to: WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Str 30 Klingenberg, Bayern 63911 GERMANY Attention: Harald Gollas The products listed

More information

Analog Universal Module HART for Zone 2 Series 9468/33

Analog Universal Module HART for Zone 2 Series 9468/33 > 8 channels can be adjusted individually as analog inputs or outputs > Intrinsically safe inputs/outputs Ex ia > For 0/4 20 ma + HART signals > Line fault monitoring per channel > Diagnostics based on

More information

General Specifications

General Specifications General Specifications EJX Series FOUNDATION TM Fieldbus Communication FOUNDATION fieldbus is the digital communication line for the field instruments, whose signal is internationally standardized by Fieldbus

More information

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER SAFE INSTALLATION MANUAL (FM APPROVAL) -WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe/explosion-proof) MODEL B6U/B6U-B BEFORE USE... SAFETY PRECAUTIONS This manual describes

More information

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater DS INSTRUCTI MANUAL RS/RS Fieldbus Isolating Repeater Din-Rail Model DS D - RS / RS Fieldbus Isolating Repeater ISM00- Characteristics General Description: The single channel DIN Rail RS / RS Fieldbus

More information

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q DQ DQ DQ D3Q INSTRUCTION MANUAL SIL 3 SIL Digital Output Loop/Bus Powered DINRail Models DQ, DQ, DQ, D3Q, D* SIL 3 SIL Digital Output Loop / Bus Powered ISM SIL Applications For Safety Related System and

More information

ATEX Installation Instructions for Micro Motion CMF400 Sensors with Booster Amplifier

ATEX Installation Instructions for Micro Motion CMF400 Sensors with Booster Amplifier Installation Instructions P/N MMI-20010152, Rev. A June 2007 for Micro Motion CMF400 Sensors with Booster Amplifier For ATEX-approved sensor installations Note: For hazardous installations in Europe, refer

More information

Attachment to Certificate IECEx PTB X

Attachment to Certificate IECEx PTB X Applicant: Electrical Apparatus: KROHNE Ltd. Measuring converter, type MFC400F Description of equipment The measuring converter, type MFC400F is used as part of a mass flow measuring system to determine

More information

Certificate of Compliance

Certificate of Compliance FF01 Certificate of Compliance Certificate: 1294176 Master Contract: 209996 Project: 1294176 Issued to: Seika Mikrosystemtechnik GmbH Ellharter StraBe 10 D-87435 Kempten GERMANY The products listed below

More information

DeltaV SIS TM Hardware Carriers

DeltaV SIS TM Hardware Carriers August 2013 Page 1 DeltaV SIS TM Hardware Carriers The DeltaV SIS modular architecture is easy to install and maintain. Flexible installation options Online expansion capability DeltaV process control

More information

ControlNet Ex Tap Terminator Installation Instructions

ControlNet Ex Tap Terminator Installation Instructions Installation Instructions Tap Terminator Installation Instructions (Cat No 1797-TCAP) Use this document as a guide when you install a ControlNet TM Ex tap terminator This document will be packaged with

More information

Model DY Vortex Flowmeter Model DYA Vortex Flow Converter Fieldbus Communication Type

Model DY Vortex Flowmeter Model DYA Vortex Flow Converter Fieldbus Communication Type User s Manual Model DY Vortex Flowmeter Model DY Vortex Flow Converter Fieldbus Communication Type Manual Change No. 11-005V-E Please use the attached sheets for the pages listed below in IM 1F6F0-01E.

More information

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q DQ DQ DQ D3Q INSTRUCTION MANUAL SIL 3 SIL Digital Output Loop/Bus Powered DINRail Models DQ, DQ, DQ, D3Q, D* SIL 3 SIL Digital Output Loop / Bus Powered ISM SIL Applications For Safety Related System and

More information

TECHNICAL WHITE PAPER DART THE NEW DIMENSION IN INTRINSIC SAFETY

TECHNICAL WHITE PAPER DART THE NEW DIMENSION IN INTRINSIC SAFETY TECHNICAL WHITE PAPER DART THE NEW DIMENSION IN INTRINSIC SAFETY Intrinsic safety is a worldwide-accepted type of ignition protection, which offers many advantages over other types of ignition protection.

More information

SafetyNet IO Modules. Safety and Distributed Control. PAC8000 SafetyNet.

SafetyNet IO Modules. Safety and Distributed Control. PAC8000 SafetyNet. SafetyNet IO Modules SafetyNet IO Modules interface to safety system field wiring via Field Terminals. The IO Modules and the Field Terminals mount on Carriers that provide mechanical support, but also

More information

Process Protection Acoustic sensors for pump monitoring

Process Protection Acoustic sensors for pump monitoring coustic sensors for pump monitoring acoustic diagnostic unit Overview The acoustic diagnostic unit acoustically measures the structure-borne noise In the version for pump monitoring; on oscillating displacement

More information

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output. GENERAL INFORMATION T6000 SERIES TRANSDUCER Electro-Pneumatic (I/P, E/P) APPLICATIONS The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional

More information

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series > Intrinsically safe output [Ex ib] IIC/IIB > Stable output voltage > Galvanic isolation between output and power supply > Power supply or 85... 230 V AC > Compact design www.stahl.de 07673E00 Basic function:

More information

STT 3000 Smart Temperature Transmitter

STT 3000 Smart Temperature Transmitter STT 3000 Smart Temperature Transmitter Foundation TM Fieldbus Model STT35F Introduction EN0I-6083 April 2009 Specification and Model Selection Guide Honeywell s microprocessor based STT35F Smart Temperature

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

FTT-10A Free Topology Twisted Pair Transceiver Model 50051

FTT-10A Free Topology Twisted Pair Transceiver Model 50051 FTT-10A Free Topology Twisted Pair Transceiver Model 50051 Description The FTT-10A Free Topology Twisted Pair Transceiver provides a simple, cost-effective method of adding a LONWORKS transceiver to any

More information

Rosemount 148 Temperature Transmitter

Rosemount 148 Temperature Transmitter Product Data Sheet Rosemount 148 Rosemount 148 Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement

More information

Universal Intelligent 2-wire DIN Rail Transmitters

Universal Intelligent 2-wire DIN Rail Transmitters Universal Intelligent 2-wire DIN Rail Transmitters IPAQ-L is a universal and intelligent 2-wire DIN rail transmitter for temperature and other measurement applications. IPAQ-LX is the Intrinsic Safe version

More information

DeltaV SISnet Fiber Components

DeltaV SISnet Fiber Components January 2013 Page 1 DeltaV SISnet Fiber Components DeltaV SIS is the world s smart SIS system to use the power of predictive intelligence for increasing the availability of the entire safety instrumented

More information

Foundation Fieldbus Control in the Field (CIF)

Foundation Fieldbus Control in the Field (CIF) Foundation Fieldbus Control in the Field (CIF) Name : Harendra G. Mistry Job Title : Chief Engineer Company : Tecnimont ICB FFIC : Automation 2011 Mumbai Foundation Fieldbus Technology Benefits Benefits

More information

Annex to IECEx PTB X Issue No.: 1. Radar sensor type series VEGAPULS PS6*.CI***H*** or VEGAPULS PS61/62/63.CI***D***

Annex to IECEx PTB X Issue No.: 1. Radar sensor type series VEGAPULS PS6*.CI***H*** or VEGAPULS PS61/62/63.CI***D*** Radar sensor type series VEGPULS PS6*.***H*** or VEGPULS PS61/62/63.***D*** The Radar sensor type series VEGPULS PS6*.***H*** or VEGPULS PS61/62/63.***D*** are used for level measurement in potentially

More information

Binary Output Series 9175

Binary Output Series 9175 Binary Output > Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring (can be switched off) > For use

More information

FLEX Ex Thermocouple/RTD Input Module

FLEX Ex Thermocouple/RTD Input Module Installation Instructions FLEX Ex Thermocouple/RTD Input Module Catalog Number 1797-IRT8 Contents For Information About See Page Important User Information 2 Module Installation 3 Installation in Zone

More information