MECHANICAL BRAKE CONTROL APPLICATION MANUAL. Software Part Number Vxx

Size: px
Start display at page:

Download "MECHANICAL BRAKE CONTROL APPLICATION MANUAL. Software Part Number Vxx"

Transcription

1 MECHANICAL BRAKE CONTROL APPLICATION MANUAL Software Part Number Vxx 2006 Avtron Industrial Automation, Inc. March 31, 2006 Cleveland, Ohio Rev. September 24, 2008

2 AVTRON INDUSTRIAL AUTOMATION, INC. Cleveland, Ohio MECHANICAL BRAKE CONTROL APPLICATION MANUAL Software Part Number Vxx TABLE OF CONTENTS SECTION PAGE I INTRODUCTION II Programming Principle of the Digital Input Signals Defining an Input for a Certain Function on Keypad Defining a Certain Function with ADDAPT ACC Programming Tool III CONTROL I/O IV PARAMETER LISTS Monitoring Values (Control Keypad: Menu M1) Basic Parameters (Control Keypad: Menu M2 G2.1) Input Signals (Control Keypad: Menu M2 G2.2) Output Signals (Control Keypad: Menu M2 G2.3) Drive Control Parameters (Control Keypad: Menu M2 G2.4) Brake Control Parameters (Control Keypad: Menu M2 G2.5) Motor Control Parameters (Control Keypad: Menu M2 G2.6) Protections (Control Keypad: Menu M2 G2.7) Autorestart Parameters (Control Keypad: Menu M2 G2.8) Identified Parameters (Control Keypad: Menu M2 G2.9) Keypad Control (Control Keypad: Menu M3) System Menu (Control Keypad: M6) Expander Boards (Control Keypad: Menu M7) V DESCRIPTION OF PARAMETERS Basic Parameters Input Signals Output Signals Drive Control Brake Control Motor Control Protections Auto Restart Parameters i

3 Table of Contents TABLE OF CONTENTS (continued) SECTION PAGE 5-9 Identified Parameters Keypad Control Parameters VI CONTROL SIGNAL LOGIC VII FAULT TRACING ii

4 Mechanical Brake Control Application SECTION I MECHANICAL BRAKE CONTROL APPLICATION 1-1 Introduction Select the Mechanical Brake Control Application in menu M6. The Mechanical Brake Control Application is typically used in applications where brake control is needed. The hardware can be any Avtron ACCel500 frequency converter. In closed loop motor control mode an encoder option board is required (Avtron P/N ). All outputs are freely programmable. Digital input functions are freely programmable to any digital input. Start forward and reverse signals are fixed to input DIN1 and DIN2 (see next page). Additional functions: Programmable Start/Stop and Reverse signal logic Reference scaling One frequency limit supervision Second ramps and S-shape ramp programming Programmable start and stop functions DC-brake at stop One prohibit frequency area Programmable U/f curve and switching frequency Autorestart Motor thermal and stall protection: Programmable action; off, warning, fault Mechanical brake control related parameters 8 digital speed references selected by 3 digital inputs IMPORTANT: Configuration information in this manual is provided to assist users in designing their own operational/functional schemes. It is deemed to be correct, however, if any errors or omissions exist, Avtron and/or Avtron representatives will not be liable to provide warranty on-site support. If one is designing his own configuration, or using one of the examples, it is highly recommended to test the operation prior to putting the drive into production. 1-1

5

6 Programming Principle of the Digital Input Signals SECTION II PROGRAMMING PRINCIPLE OF THE DIGITAL INPUT SIGNALS The programming principle of the input signals in the Mechanical brake control Application as well as in the Multipurpose Control Application (and partly in the other applications) is different compared to the conventional method used in other Avtron ACCel500 applications. In the conventional programming method, Function to Terminal Programming Method (FTT), you have a fixed input that you define a certain function for. The applications mentioned above, however, use the Terminal to Function Programming method (TTF) in which the programming process is carried out the other way round: Functions appear as parameters that the operator defines a certain input for (see Figure 2-1). Figure 2-1. Basic Principle of the Terminal to Function Programming Method (TTF) NOTE A constant value can be given to an input signal. Value 0.1 is a constant FALSE and values from 0.2 through 0.10 are constant TRUE (see Figure 2-1). 2-1

7 Programming Principle of the Digital Input Signals 2-1 Defining an Input for a Certain Function On Keypad Connecting a certain function (input signal) to a certain digital input is done by giving the parameter an appropriate value. The value is formed of the Board slot on the ACCel500 control board (see ACCel500 User's Manual, Chapter 4) and the respective signal number, see below. Function name Terminal type Slot Terminal number Example: You want to connect the digital input function Fault Reset (parameter ) to a digital input A.3 on the basic I/O board located in Slot A. First find the parameter on the keypad. Press the Menu button right once to enter the edit mode. On the value line, you will see the terminal type on the left (DigIN) and on the right, digital input where function is connected. When the value is blinking, hold down the Browser button up or down to find the desired board slot and signal number. The program will scroll the board slots starting from 0 and proceeding from A to E and the I/O numbers from 1 to 10. Once you have set the desired value, press the Enter button once to confirm the change. > 2-2

8 Programming Principle of the Digital Input Signals 2-2 Defining a Certain Function with ADDAPT ACC Programming Tool If you use the ADDAPT ACC programming tool for assigning parameter values, you will have to establish the connection between the function and input/output in the same way as with the control panel. Just pick the address code from the drop-down menu in the Value column (see Figure 2-2). Figure 2-2. Screenshot of ADDAPT ACC Programming Tool; Entering the Address Code NOTE Two inputs signals can be connected to same digital input. Use this feature very cautiously. 2-3

9

10 Control I/O SECTION III CONTROL I/O TABLE 3-1. DEFAULT I/O CONFIGURATION ACCel500 Slot A Terminal Signal Description 1 +10V ref Reference output Voltage for potentiometer, etc. 2 AI1+ Analog input, voltage range 0 10V DC Voltage input frequency reference 3 AI1- I/O Ground Ground for reference and controls 4 AI2+ Analog input, current range 0 Current input frequency reference 5 AI2-20mA 6 +24V Control voltage output Voltage for switches, etc. max 0.1 A 7 GND I/O ground Ground for reference and controls 8 DIN1 Start forward Contact closed = start forward (programmable) 9 DIN2 Start reverse Contact closed = start reverse (programmable) 10 DIN3 External fault input (programmable) Contact open = no fault Contact closed = fault 11 CMA Common for DIN 1 DIN 3 Connect to GND or +24V V Control voltage output Voltage for switches (see #6) 13 GND I/O ground Ground for reference and controls 14 DIN4 Programmable. 15 DIN5 Programmable READY ma 16 DIN6 Fault reset (programmable) Contact open = no action Contact closed = fault reset 17 CMB Common for DIN4 DIN6 Connect to GND or +24V 18 AO1+ Output frequency Programmable 19 AO1- Analog output Range 0 20 ma/r L, max. 500Ω 20 DO1 Digital output READY ACCel500 Slot B 21 RO1 22 RO1 23 RO1 Relay output 1 Brake open signal Programmable Open collector, I 50mA, U 48 VDC Programmable 220 VAC 24 RO2 25 RO2 26 RO2 Relay output 2 FAULT Programmable Note: See jumper selections below. More information in the product s User's Manual. Jumper block X3: CMA and CMB grounding CMB connected to GND CMA connected to GND CMB isolated from GND CMA isolated from GND CMB and CMA internally connected together, isolated from GND = Factory default 3-1

11

12 Parameter Lists SECTION IV PARAMETER LISTS On the next pages you will find the lists of parameters within the respective parameter groups. The parameter descriptions are given in Section V. Column explanations: Code = Location indication on the keypad; Shows the operator the present parameter number Parameter = Name of parameter Min = Minimum value of parameter Max = Maximum value of parameter Unit = Unit of parameter value; Given if available Default = Value preset by factory Cust = Customer s own setting ID = ID number of the parameter (used with PC tools) = In parameter row: Use TTF method to program these parameters. = On parameter code: Parameter value can only be changed after the frequency converter has been stopped. 4-1 Monitoring values (Control keypad: menu M1) The monitoring values are the actual values of parameters and signals as well as statuses and measurements. Monitoring values cannot be edited. See Avtron ACCel500 User's Manual, Chapter 5 for more information. TABLE 4-1. MONITORING VALUES Code Parameter Unit ID Description V1.1 Output frequency Hz 1 Output frequency to motor V1.2 Frequency reference Hz 25 Frequency reference to motor control V1.3 Motor speed rpm 2 Motor speed in rpm V1.4 Motor current A 3 V1.5 Motor torque % 4 In % of the nominal motor torque V1.6 Motor power % 5 Motor shaft power V1.7 Motor voltage V 6 V1.8 DC link voltage V 7 V1.9 Unit temperature C 8 Heatsink temperature V1.10 Voltage input V 13 AI1 V1.11 Current input ma 14 AI2 V1.12 DIN1, DIN2, DIN3 15 Digital input statuses V1.13 DIN4, DIN5, DIN6 16 Digital input statuses V1.14 DO1, RO1, RO2 17 Digital and relay output statuses V1.15 Analog I out ma 26 AO1 V1.16 Encoder speed rpm 1501 Encoder speed in rpm V1.17 Calculated sync speed rpm 1502 Calculated synchronous speed V1.18 Torque % 1125 Unfiltered motor torque V1.19 Current A 1113 Unfiltered motor current V1.20 DC Voltage V 44 Unfiltered DC Voltage V1.21 Status Word 43 Drive status word V1.22 Encoder 1 Freq Hz 1124 Shaft Frequency G1.23 Multimonitor Multimonitor page 4-1

13 Parameter Lists 4-2 Basic parameters (Control keypad: Menu M2 G2.1) TABLE 4-2. BASIC PARAMETERS G2.1 Code Parameter Min Max Unit Default Cust ID Note P2.1.1 Min frequency 0.00 Par Hz P2.1.2 Max frequency Par Hz P2.1.3 Accel Time s P2.1.4 Decel Time s P2.1.5 Current limit 0.1 x I L 2.5 x I L A 1.5 x I L 107 P2.1.6 Motor Nom Voltg V 230V 400V 690V P2.1.7 Motor Nom Freq Hz P2.1.8 Motor Nom Speed ,000 rpm P2.1.9 Motor Nom Currnt 1 x I L 2.5 x I L A I L 113 P Motor cosϕ P I/O Reference P Keypad Ctrl Ref P Fieldbus Ctr Ref P Digital Ref Par Hz P Digital Ref Par Hz P Digital Ref Par Hz P Digital Ref Par Hz NOTE: If f max > than the motor synchronous speed, check suitability for motor and drive system NOTE: This applies for frequency converters up to FR7. For greater sizes, consult the factory. Check the rating plate of the motor The default applies for a 4-pole motor and a nominal size frequency converter. Check the rating plate of the motor Check the rating plate of the motor 0 = AI1 1 = AI2 2 = Keypad 3 = Fieldbus 4 = Digital 5 = Joystick (Voltage input) 6 = Motor potentiometer 0 = AI1 1 = AI2 2 = Keypad 3 = Fieldbus 0 = AI1 1 = AI2 2 = Keypad 3 = Fieldbus Digital reference preset by operator NOTE: Not used in this software application. 4-2

14 Parameter Lists 4-3 Input signals (Control keypad: Menu M2 G2.2) TABLE 4-3. INPUT SIGNALS, G2.2 Code Parameter Min Max Unit Default Cust ID Note P2.2.1 Curr Ref Offset = No offset 1 = 4 20 ma P2.2.2 Ref Scal Min Val 0.00 par Hz Selects the frequency that corresponds to the min. reference signal 0.00 = No scaling P2.2.3 Ref Scal Max Val Hz Selects the frequency that corresponds to the max. reference signal 0,00 = No scaling P2.2.4 Ref Invert = Not inverted 1 = Inverted P2.2.5 Ref Filter Time s = No filtering P2.2.6.x Digital Inputs P Fault Reset 0 E.10 DigIN: P Ext Fault Close 0 E.10 DigIN:A P Ext Fault Open 0 E.10 DigIN: P Run Enable 0 E.10 DigIN: P Acc/Dec Time Sel 0 E.10 DigIN: P Reverse 0 E.10 DigIN: P Param Set Set1/Set2 0 E.10 DigIN: P Ext Brake SuperV 0 E.10 DigIN: P Digital Ctrl LSB 0 E.10 DigIN: P Digital Ctrl MSB 0 E.10 DigIN: P MotPotAccellerat 0 E.10 DigIN: P Ext Brake Ctrl 0 E.10 DigIN: P Dual Brake Ctrl 0 E.10 DigIN: P2.2.7.x Non-Linearization P NonLin X 1 Cord ,00 % P NonLin Y 1 Cord % P NonLin X 2 Cord % P NonLin Y 2 Cord % * = Rising edge required to start 4-3

15 Parameter Lists 4-4 Output signals (Control keypad: Menu M2 G2.3) TABLE 4-4. OUTPUT SIGNALS, G2.3 Code Parameter Min Max Unit Default Cust ID Note P2.3.1 Iout Content = Not used 1 = Output freq. (0 f max ) 2 = Freq. reference (0 f max ) 3 = Motor speed (0 Motor nominal speed) 4 = Output current (0-I nmotor ) 5 = Motor torque (0 T nmotor ) 6 = Motor power (0 P nmotor ) 7 = Motor voltage (0-U nmotor ) 8 = DC-link volt (0 1000V) P2.3.2 Iout Filter Time s P2.3.3 Iout Invert = Not inverted 1 = Inverted P2.3.4 Iout Minimum = 0 ma 1 = 4 ma P2.3.5 Iout Scale % P2.3.6 DO1 Content = None/WD Timer 1 = Ready 2 = Run 3 = Fault 4 = Fault inverted 5 = FC overheat warning 6 = Ext. fault or warning 7 = Ref. fault or warning 8 = Warning 9 = Reversed 10 = Preset speed 11 = At speed 12 = Mot. regulator active 13 = OP freq. limit superv. 14 = Control place: IO 15 = Therm Fault/Warning 16 = FB DigIN 1 17 = Open external Brake 18 = Open Enable P2.3.7 RO1 Content As parameter P2.3.8 RO2 Content As parameter P2.3.9 Freq Supv Lim = No limit 1 = Low limit supervision 2 = High limit supervision P Freq Supv Val 1 0, Hz P Iout 2 Signal TTF programming method used. P Iout 2 Content As parameter P Iout 2 Filter T s P Iout 2 Invert = Not inverted 1 = Inverted P Iout 2 Minimum = 0 ma 1 = 4 ma P Iout 2 Scale %

16 Parameter Lists 4-5 Drive control parameters (Control keypad: Menu M2 G2.4) TABLE 4-5. DRIVE CONTROL PARAMETERS, G2.4 Code Parameter Min Max Unit Default Cust ID Note P2.4.1 Ramp 1 Shape s = Linear >0 = S-curve ramp time P2.4.2 Ramp 2 Shape s = Linear >0 = S-curve ramp time P2.4.3 Accel Time s P2.4.4 Decel Time s P2.4.5 Brake Chopper = Disabled 1 = Used when running 2 = External brake chopper 3 = Used when stopped/running 4 = Used when running, no test P2.4.6 Start Function = Ramp 1 = Flying start P2.4.7 Stop Function = Coasting 1 = Ramp 2 = Ramp+Run enable coast 3 = Coast+Run enable ramp P2.4.8 Flux Brake = Off 1 = On P2.4.9 FluxBrakeCurrent 0.0 Varies A P RampChangeFreq 0.0 Par Hz Acc/dec. ramps 2 are used below this frequency P x Prohibit freq P Range 1 Low Lim 0.00 par Hz P Range 1 High Lim Hz P PH Acc/Dec Ramp x P Fwd Slw Dwn Spd 0 60 Hz Active when P is LOW. P Fwd Low Spd Hz First step fixed FWD speed reference. P Fwd High Spd Hz Second step fixed speed reference (if P is LOW). P Fwd Ext Spd Hz Second step fixed speed reference (if P is HI) P Rev Slw Dwn Spd 0 60 Hz Active when P is LOW. P Rev Low Spd Hz First step fixed REV speed reference. P Rev High Spd Hz Second step fixed speed reference (if P is LOW). P Rev Ext Spd Hz Second step fixed speed reference (if P is HI). P Fwd Slw Dwn Inp 0 E.10 DigIN:0.2 0 = In Slowspeed zone. 1 = Normal Speed zone. P Rev Slw Dwn Inp 0 E.10 DigIN:0.2 0 = In Slowspeed zone. 1 = Normal Speed zone. P Fast Spd Inp 0 E.10 DigIN:0.1 0 = Use First Step Speed reference. 1 = Use Second Step Speed reference. P Ext Spd Cur Lim % Current limit in extended speed range. 4-5

17 Parameter Lists Code Parameter Min Max Unit Default Cust ID Note P Ext Spd Inp 0 E.10 DigIN:0.1 0 = Use P and P second step speed. 1 = Use P and P second step speed. P Ld Float Bit ID 0 E.10 DigIN:0.1 0 = Load Float disabled. 1 = Load Float enabled. P Load Float TC s Load Float time. P Load Float Spd 0 60 Hz 5.00 Load Float Speed ref. P LF Trq Prv Spd Hz 5.00 P REV End Inp ID 0 E.10 DigIN:0.2 Reverse Direction Travel Limit 0 = Stop 1 = OK P FWD End Inp ID 0 E.10 DigIN:0.2 Forward Direction Travel Limit 0 = Stop 1 = OK P Brake Close Time s 0.10 P En Brake Slip F = Disable 1 = Enable P Brake Slip Freq 0 10 Hz 4.00 P Over Wt Delay s 2.00 P En Over Wt Fault = Disable 1 = Enable P Over Wt Flt Stpt % P Brk Slip DOUT ID 0 E.10 DigOUT:0. Brake slip Detection warning P Over Wt Out ID 0 E.10 1 DigOUT:0. 1 P End Stop Mode output Overweight Detection warning output 0 = Normal Stop 1 = Fast Stop 2 = Coast Stop 4-6

18 Parameter Lists 4-6 Brake control parameters (Control keypad: Menu M2 G2.5) TABLE 4-6. BRAKE CONTROL PARAMETERS, G2.5 Code Parameter Min Max Unit Default Cust ID Note P2.5.1.x OPEN LOOP PARAMETERS P CurrentLimit FWD 0.0 P2.1.9 A P CurrentLimit REV 0.0 P2.1.9 A P TorqueLimit FWD % P TorqueLimit REV % P Freq limit FWD 0.00 P2.1.7 Hz P Freq limit REV 0.00 P2.1.7 Hz P MecBreakClosDFWD s P MecBreakClosDREV s P FreqLimClos FWD 0.00 P2.1.7 Hz P FreqLimClos REV 0.00 P2.1.7 Hz P MecBrakeClosDFWD s P MecBrakeClosDREV s P MaxFreqBrakeClos 0.00 P2.1.2 Hz P MecBrakReactTime s P DC-Brake Current 0.15 x I n 1.5 x I n A Varies 507 P Start DC-BrakeTM s = DC brake is off at start P Stop DC-BrakeTM s = DC brake is off at stop P Stop DC-BrakeFr Hz P DirectChangeMode P2.5.2.x CLOSED LOOP PARAMETERS P CurrentLimit 0.0 P2.1.9 A P TorqueLimit % P FreqLimit 0.00 P2.1.7 Hz P MecBrakeOpenDela s P FreqLimClose 0.00 P2.1.7 Hz P MecBrakeClosDela s P MaxFreqBrakeClos 0.00 P2.1.2 Hz P MecBrakReactTime s P Hz TimeAtStart s P Hz TimeAtStop s P SmoothStartTime s P SmoothStartFreq 0.00 P2.1.2 s P DirectChangeMode = No action 1 = Brake closed 2 = Stop state 0 = No action 1 = Brake closed 2 = Stop state P Start Magn Curr 0.00 I L A Start magnetizing current P Start Magn Time ms Start magnetizing time 4-7

19 Parameter Lists 4-7 Motor control parameters (Control keypad: Menu M2 G2.6) TABLE 4-7. MOTOR CONTROL PARAMETERS, G2.6 Code Parameter Min Max Unit Default Cust ID Note P2.6.1 Motor Ctrl Mode = OL, Frequency control 1 = OL, Speed control 2 = OL, Torque control 3 = CL, Speed control 4 = CL, Torque control 5 = Advanced OL Freq 6 = Advanced OL Speedl P2.6.2 U/f Optimization = Not used 1 = Automatic torque boost P2.6.3 U/f Ratio Select = Linear 1 = Squared 2 = Programmable 3 = Linear with flux optim. P2.6.4 Field WeakngPnt Hz P2.6.5 Voltage at FWP % n% x U nmot Parameter max. value = par P2.6.6 U/f Mid Freq 0.00 par. P2.6.4 Hz P2.6.7 U/f Mid Voltg % N% x U nmot P2.6.8 Zero Freq Voltg % N% x U nmot P2.6.9 Switching Freq khz Varies 601 Depends on kw P Overvolt Contr = Not used 1 = Used P Undervolt Contr = Not used 1 = Used P SlipCompensation P OL Speed Reg P P OL Speed Reg I P LoadDrooping % P Identification = Calculated 1 = Encoder speed 0 = No action 1 = Identification w/o run 2 = Identification with run CLOSED LOOP P x PARAMETERS P MagnCurrent 0, A 612 P Speed Control Kp Gain for the speed controller Time constant for the speed P Speed Control Ti Ms controller P CurrentControlKp % P Encoder1FiltTime ms P Slip Adjust % = Not Used P StartupTorqueSel = TorqMemory 140 Stop state magnetizing P StopStateFlux % Current P Flux Off Delay s P x ADVANCED OPEN LOOP PARAMETERS P Speed Current % P Minimum Current % P FluxReference % P Frequency Limit % P M5 StrayFluxCurr 0, % Max time for stop state magnetization 4-8

20 Parameter Lists 4-8 Protections (Control keypad: Menu M2 G2.7) TABLE 4-8. PROTECTIONS, G2.7 Code Parameter Min Max Unit Default Cust ID Note P mA Input Fault P mA Fault Freq Par Hz P2.7.3 External Fault P2.7.4 Input Phase Supv P2.7.5 UVolt Fault Resp P2.7.6 OutputPh. Superv P2.7.7 Earth Fault P2.7.8 Motor Therm Prot P2.7.9 MotAmbTemp Factor % P MTP f0 Current % P MTP Motor T min P Motor Duty Cycle % P Stall protection P Stall Current A P Stall Time Lim s P Stall Freq Limit 1,0 Par Hz P Underload Protec P UP fnom Torque % P UP f0 Torque % P UP Time Limit s P ThermistorF.Resp P FBComm.Fault Resp See P P SlotComFaultResp See P P BrakeSuperVFault P BrakeSuperV Time s P BrakeLogicSFault P BrakeLogicSVTime s P UnderCurrent Fa P UnderCurrentSup 0.0 P A P Shaftspeed SV P ShaftspeedSHyst ,00 Hz P ShaftspeedSTime ,00 s = No response 1 = Warning 2 = Warning+Old Freq. 3 = Wrng+PresetFreq = Fault,stop acc. to = Fault,stop by coasting 0 = No response 1 = Warning 2 = Fault,stop acc. to = Fault,stop by coasting 0 = No response 1 = Warning 2 = Fault,stop acc. to = Fault,stop by coasting 0 = No response 1 = Warning 2 = Fault,stop acc. to = Fault,stop by coasting 0 = No response 1 = Warning 2 = Fault,stop acc. to = Fault,stop by coasting 4-9

21 Parameter Lists 4-9 Autorestart parameters (Control keypad: Menu M2 G2.8) TABLE 4-9. AUTORESTART PARAMETERS, G2.8 Code Parameter Min Max Unit Default Cust ID Note P2.8.1 Wait Time s P2.8.2 Trial Time s P2.8.3 Start Function = Ramp 1 = Flying start 2 = According to par P2.8.4 Undervolt. Tries P2.8.5 Overvolt Tries P2.8.6 Overcurr. Tries P mA Fault Tries P2.8.8 MotTempF Tries P2.8.9 Ext.Fault Tries

22 Parameter Lists 4-10 Identified parameters (Control keypad: Menu M2 G2.9) Parameters are updated when the automatic motor identification is done. The identification is activated by parameter P and start order within 20 seconds. It is also possible to change these parameters manually but then a very good knowledge in motor tuning is required. TABLE IDENTIFIED PARAMETERS Code Parameter Min Max Unit Default Cust ID Note P2.9.1 Flux 10 % % Flux linearization point 10% P2.9.2 Flux 20 % % Flux linearization point 20% P2.9.3 Flux 30 % % Flux linearization point 30% P2.9.4 Flux 40 % % Flux linearization point 40% P2.9.5 Flux 50 % % Flux linearization point 50% P2.9.6 Flux 60 % % Flux linearization point 60% P2.9.7 Flux 70 % % Flux linearization point 70% P2.9.8 Flux 80 % % Flux linearization point 80% P2.9.9 Flux 90 % % Flux linearization point 90% P Flux 100 % % Flux linearization point 100% P Flux 110 % % Flux linearization point 110% P Flux 120 % % Flux linearization point 120% P Flux 130 % % Flux linearization point 130% P Flux 140 % % Flux linearization point 140% P Flux 150 % % Flux linearization point 150% P MakeFluxTime Varies 660 Time to magnetize the motor P MakeFluxVoltage Varies 661 Magnetizing voltage P Measured voltage drop at stator RsVoltageDrop Varies 662 resistance between two phases with nominal current of the motor P MFVhwDtComp Varies 663 Magnetizing voltage with hardware dead time compensation P IRaddZeroPointV % Varies 664 IrAddVoltage for Zero frequency, used with torque boost. P IrAddGeneScale % Varies 665 Scaling factor for generator side IRcompensation. P IrAddMotorScale % Varies 667 Scaling factor for motor side IRcompensation. P IU Offset Offsets value for phase U current measurement. P IV Offset Offsets value for phase V current measurement. P IW Offset Offsets value for phase W current measurement. 4-11

23 Parameter Lists 4-11 Keypad control (Control keypad: Menu M3) The parameters for the selection of control place and direction on the keypad are listed below. See the Keypad control menu in the Avtron ACCel500 User s Manual. TABLE KEYPAD CONTROL PARAMETERS, M3 Code Parameter Min Max Unit Default Cust ID Note P3.1 Control Place = I/O terminal 1 = Keypad 2 = Fieldbus R3.2 Keypad Reference Par. Par Hz P3.3 Keypad Direction = Forward 1 = Reverse R3.4 StopButtonActive =Limited function of Stop button 1 =Stop button always enabled 4-12 System menu (Control keypad: M5) For parameters and functions related to the general use of the frequency converter, such as application and language selection, customised parameter sets or information about the hardware and software, see Chapter 5 in the Avtron ACCel500 User s Manual Expander boards (Control keypad: Menu M6) The M6 menu shows the expander and option boards attached to the control board and boardrelated information. For more information, see Chapter 5 in the Avtron ACCel500 User s Manual. 4-12

24 SECTION V DESCRIPTION OF PARAMETERS 5-1 Basic Parameters Minimum frequency Maximum frequency Defines the frequency limits of the frequency converter. The maximum value for parameters and is 320 Hz. The software will automatically check the values of parameters , , , , and Acceleration time Deceleration time 1 These limits correspond to the time required for the output frequency to accelerate from the zero frequency to the set maximum frequency (par ) Current limit This parameter determines the maximum motor current from the frequency converter. To avoid motor overload, set this parameter according to the rated current of the motor. The current limit is 1.5 times the rated current (I L ) by default Nominal voltage of the motor Find this value U n on the rating plate of the motor. This parameter sets the voltage at the field weakening point (parameter 2.6.5) to 100% x U nmotor Nominal frequency of the motor Find this value f n on the rating plate of the motor. This parameter sets the field weakening point (parameter 2.6.4) to the same value Nominal speed of the motor Find this value n n on the rating plate of the motor Nominal current of the motor Find this value I n on the rating plate of the motor Motor cos phi Find this value cos phi on the rating plate of the motor. 5-1

25 I/O frequency reference selection Defines which frequency reference source is selected when controlled from the I/O control place. Default value is 0. 0 = Analog voltage reference from terminals 2 3, e.g., potentiometer 1 = Analog current reference from terminals 4 5, e.g., transducer 2 = Keypad reference from the Reference Page (Group M3) 3 = Reference from the fieldbus 4 = Digital reference, frequency is set according to parameters P to P = Joystick control, U in reference from terminals = Internal motorized potentiometer Digital input P can be used as internal motorized potentiometer. Drive is started and the digital input increases speed. The current speed is held as long as start command is active. Deceleration is made by stop command Keypad frequency reference selection Defines which frequency reference source is selected when controlled from the keypad. Default value is 2. 0 = Analog voltage reference from terminals 2 3, e.g. potentiometer 1 = Analog current reference from terminals 4 5, e.g. transducer 2 = Keypad reference from the Reference Page (Group M3) 3 = Reference from the Fieldbus Fieldbus frequency reference selection Defines which frequency reference source is selected when controlled from the fieldbus. Default value is 3. 0 = Analog voltage reference from terminals 2 3, e.g. potentiometer 1 = Analog current reference from terminals 4 5, e.g. transducer 2 = Keypad reference from the Reference Page (Group M3) 3 = Reference from the Fieldbus Digital reference (NOT USED) 5-2

26 5-2 INPUT SIGNALS Start/Stop Logic Though not configurable, it should be noted that the ACCel500 s first two digital inputs are reserved specifically for enabling the drive to run in dedicated directions, as described below. DigIN:A.1 (digital input 1): closed contact = start forward DigIN:A.2 (digital input 2): closed contact = start reverse FWD Output frequency Stop function (par 2.4.7) = coasting t REV DIN1 DIN2 Figure 5-1. Start forward/start reverse NX12K09 The first selected direction has the highest priority. When the DIN1 contact opens the direction of rotation starts the change. If Start forward (DIN1) and Start reverse (DIN2) signals are active simultaneously the Start forward signal (DIN1) has priority. 1 DIN1: closed contact = start open contact = stop DIN2: closed contact = reverse open contact = forward See Figure

27 FWD Output frequency Stop function (par = coasting t REV DIN1 DIN2 NX12K10 Figure 5-2. Start, Stop, Reverse 2 DIN1: closed contact = start open contact = stop DIN2: closed contact = start enabled open contact = start disabled and drive stopped if running 3 3-wire connection (pulse control): DIN1: closed contact = start pulse DIN2: open contact = stop pulse (DIN3 can be programmed for reverse command) See Figure 5-3. FWD Output frequency Stop function (par 2.4.7) = coasting If Start and Stop pulses are simultaneous the Stop pulse overrides the Start pulse t REV DIN1 Start DIN2 Stop Figure 5-3. Start pulse/ Stop pulse NX012K11 5-4

28 The selections 4 to 6 shall be used to exclude the possibility of an unintentional start when, for example, power is connected, re-connected after a power failure, after a fault reset, after the drive is stopped by Run Enable (Run Enable = False) or when the control place is changed. The Start/Stop contact must be opened before the motor can be started. 4 DIN1: closed contact = start forward (Rising edge required to start) DIN2: closed contact = start reverse (Rising edge required to start) 5 DIN1: closed contact = start (Rising edge required to start) open contact = stop DIN2: closed contact = reverse open contact = forward 6 DIN1: closed contact = start (Rising edge required to start) open contact = stop DIN2: closed contact = start enabled open contact = start disabled and drive stopped if running Reference offset for current input 0 No offset 1 Offset 4 ma ( living zero ), provides supervision of zero level signal. The response to reference fault can be programmed with parameter Reference scaling, minimum value/maximum value Setting value limits: 0 par par par If parameter = 0 scaling is set off. The minimum and maximum frequencies are used for scaling. Figure 5-4. Left: Reference scaling; Right: No scaling used (par = 0) 5-5

29 2.2.4 Reference inversion Inverts reference signal: Max. ref. signal = Min. set freq. Min. ref. signal = Max. set freq. 0 No inversion 1 Reference inverted Figure 5-5. Reference inversion Reference filter time Filters out disturbances from the incoming analog U in signal. Long filtering time makes regulation response slower. Figure 5-6. Reference filtering 5-6

30 2.2.6.x DIGITAL INPUTS All digital Inputs (not DigIN:0.1 and DigIN:0.2) shall be programmed using the Terminal To Function method (TTF). See instructions in Section II. In other words, all functions (parameters) that you wish to use shall be connected to a certain input on a certain option board Fault reset Contact closed: All faults are reset External Fault closing contact Contact closed: Fault is displayed and motor stopped External Fault opening contact Contact open: Fault is displayed and motor stopped Run Enable Treat this parameter as a Ready to Run permissive. Regardless of direction, this parameter must have a high bit in order to spin motor. Contact open: Start of motor disabled Contact closed: Start of motor enabled Acc/Dec time selection Set Acceleration/Deceleration times 2 with parameters P2.4.3 and P2.4.4 Contact open: Contact closed: Acceleration/Deceleration time 1 selected Acceleration/Deceleration time 2 selected Reverse Even though DigIN:A.2 is a dedicated reverse motor direction input, set this parameter equal to the reverse direction input as well. Contact open: Contact closed: Direction forward Direction reverse Parameter set 1 / set 2 With this parameter you can select between Parameter Set 1 and Set 2. Digital input = FALSE: - The active set is saved to set 2 - Set 1 is loaded as the active set Digital input = TRUE: - The active set is saved to set 1 - Set 2 is loaded as the active set Note: The parameter values can be changed in the active set only. 5-7

31 External brake supervision External supervision of the mechanical brake. The Boolean value is forced to TRUE if function is not connected to a digital input. Contact open: Contact closed: Mechanical brake closed Mechanical brake opened Speed select 1 (NOT USED) Speed select 2 (NOT USED) Motorized potentiometer acceleration Acc/dec ramp times 2 can be used below frequency set by parameter P Frequencies above the limit set by P uses acc/dec ramp times 1. Contact open: Contact closed: Maintain current speed Acceleration External brake control Digital input can be used as an external opening condition in the brake opening logic. The Boolean value is forced to TRUE if function is not connected to a digital input. Contact open: Contact closed: FALSE TRUE 5-8

32 Dual brake control If running the machine with two ACCel500 drives, this function is to gain synchronized brake and ramp control. The Open enable signal from the other drive is connected to the Dual brake control digital output and the other drive is connected the other way round. An example of the Dual brake control connections can be seen in Figure 5-7. Contact open: Contact closed: The brake doesn t open Open enable Drive 1 Drive 2 Digital output: Open enable Digital input: Dual brake control Digital input: Dual brake control Digital output: Open enable Figure 5-7. Dual brake control connections x Non-linearization Non-linear response of the analog inputs NonLinearization coordinate X NonLinearziation coordinate Y NonLinearization coordinate X NonLinearization coordinate Y 2 Output frequency 100% P (x 2 ; y 2 ) P (x 1 ; y 1 ) Reference P P % Figure 5-8. Non-Linearization of the analog inputs 5-9

33 5-3 OUTPUT SIGNALS Analog output function This parameter selects the desired function for the analog output signal. See Table 4-4 for the parameter values Analog output filter time Defines the filtering time of the analog output signal. % 100% Unfiltered signal 63% Filtered signal t [s] Par Figure 5-9. Analog output filtering NX12K Analog output invert Inverts the analog output signal. Maximum output signal = Minimum set value Minimum output signal = Maximum set value See parameter below. Figure Analog output invert 5-10

34 2.3.4 Analog output minimum Defines the signal minimum to either 0 ma or 4 ma (living zero). Note the difference in analog output scaling in parameter (Figure 5-11). 0 Set minimum value to 0 ma 1 Set minimum value to 4 ma Analog output scale Scaling factor for Analog output. TABLE 5-1. ANALOG OUTPUT SCALING Signal Max. value of the signal Output frequency Max frequency (par ) Freq. Reference Max frequency (par ) Motor speed Motor nom. speed 1xn mmotor Output current Motor nom. current 1xI nmotor Motor torque Motor nom. torque 1xT nmotor Motor power Motor nom. power 1xP nmotor Motor voltage 100% x U nmotor DC-link voltage 1000 V Analogue output current 20 ma Param = 200% Param = 100% 12 ma 10 ma Param = 50% Par = 1 4 ma Par = 0 0 ma Max. value of signal selected by param UD012K18 Figure Analog output scaling Digital output function Programmable. Set to 0/None/WDTim for output of software watchdog toggle bit Relay output 1 function Typically used for brake control output. 5-11

35 2.3.8 Relay output 2 function TABLE 5-2. OUTPUT SIGNALS VIA DO1 AND OUTPUT RELAYS RO1 AND RO2 Setting value Signal content 0 = Not used Out of operation Digital output DO1 sinks the current and programmable relay (RO1, RO2) is activated when: 1 = Ready The frequency converter is ready to operate 2 = Run The frequency converter operates (motor is running) 3 = Fault A fault trip has occurred 4 = Fault inverted A fault trip not occurred 5 = Overheat warning The heat-sink temperature exceeds +70 C 6 = External fault or warning Fault or warning depending on par = Reference fault or warning Fault or warning depending on par if Analog reference is 4 20 ma and signal is <4mA 8 = Warning Always if a warning exists 9 = Reversed The reverse command has been selected 10 = Preset speed The preset speed has been selected with digital input 11 = At speed The output frequency has reached the set reference 12 = Motor regulator activated Overvoltage or overcurrent regulator was activated 13 = Output frequency supervision The output frequency goes outside the set supervision low limit/high limit (see parameters and below) 14 = Control from I/O terminals I/O control mode selected (in menu M3) 15 = Therm. Fault/Warn 16 = FB DigIN 1 17 = Brake open Brake open signal to the mechanical brake 18 = Open enable Open enable signal (Dual brake control) Output frequency limit supervision function If the output frequency goes under/over the set limit (P ) this function generates a warning message via the digital output DO1 and via the relay output RO1 or RO2 depending on the settings of parameters to No supervision 1 Low limit supervision 2 High limit supervision 5-12

36 Output frequency limit supervision value Selects the frequency value supervised by parameter f[hz] Par = 2 Par t Example: 21 RO1 22 RO1 23 RO1 21 RO1 22 RO1 23 RO1 21 RO1 22 RO1 23 RO1 Figure Output frequency supervision NX12K Analog output 2 signal selection Connect the AO2 signal to the analog output of your choice with this parameter. For more information, see Pump and Fan Control Application Manual, Chapter Analog output 2 function Analog output 2 filter time Analog output 2 inversion Analog output 2 minimum Analog output 2 scaling For more information on these five parameters, see the corresponding parameters for the analog output 1 (parameters to 2.3.5). 5-13

37 5-4 DRIVE CONTROL Acceleration/Deceleration ramp 1 shape Acceleration/Deceleration ramp 2 shape The start and end of acceleration and deceleration ramps can be smoothed with these parameters. Setting value 0 gives a linear ramp shape which causes acceleration and deceleration to act immediately to the changes in the reference signal. Setting value 0.1 to 10 seconds for this parameter produces an S-shaped acceleration/deceleration. The acceleration time is determined with parameters 2.1.3/2.1.4 (2.4.3/2.4.4). [Hz] 2.1.3, (2.4.3, 2.4.4) (2.4.2) (2.4.2) [t] UD012K20 Figure Acceleration/Deceleration (S-shaped) Acceleration time Deceleration time 2 These values correspond to the time required for the output frequency to accelerate from the zero frequency to the set maximum frequency (par ). These parameters give the possibility to set two different acceleration/deceleration time sets for one application. The active set can be selected with the programmable signal DIN3 (par ). 5-14

38 2.4.5 Brake chopper When the frequency converter is decelerating the motor, the inertia of the motor and the load are fed into an external brake resistor. This enables the frequency converter to decelerate the load with a torque equal to that of acceleration (provided that the correct brake resistor has been selected). 0 = No brake chopper used 1 = Brake chopper in use when running 2 = External brake chopper 3 = Used when stopped/running 4 = Brake chopper in use when running, no test Start function Ramp: 0 The frequency converter starts from 0 Hz and accelerates to the set reference frequency within the set acceleration time. (Load inertia or starting friction may cause prolonged acceleration times). Flying start: 1 The frequency converter is able to start into a running motor by applying a small torque to motor and searching for the frequency corresponding to the speed the motor is running at. Searching starts from the maximum frequency towards the actual frequency until the correct value is detected. Thereafter, the output frequency will be increased/decreased to the set reference value according to the set acceleration/deceleration parameters. Use this mode if the motor is coasting when the start command is given. With the flying start it is possible to ride through short mains voltage interruptions Stop function Coasting: 0 The motor coasts to a halt without any control from the frequency converter, after the Stop command. Ramp: 1 After the Stop command, the speed of the motor is decelerated according to the set deceleration parameters. If the regenerated energy is high it may be necessary to use an external braking resistor for faster deceleration. Normal stop: Ramp/ Run Enable stop: coasting 2 After the Stop command, the speed of the motor is decelerated according to the set deceleration parameters. However, when Run Enable is selected (e.g. DIN3), the motor coasts to a halt without any control from the frequency converter. Normal stop: Coasting/ Run Enable stop: ramping 3 The motor coasts to a halt without any control from the frequency converter. However, when Run Enable signal is selected (e.g. DIN3), the speed of the motor is decelerated according to the set deceleration parameters. If the regenerated energy is high it may be necessary to use an external braking resistor for faster deceleration. 5-15

39 2.4.8 Flux brake The flux braking can be set ON or OFF. 0 = Flux braking OFF 1 = Flux braking ON Flux braking current Defines the flux braking current value Ramp change frequency, Motorized potentiometer. Acceleration and deceleration times 2 (P2.4.3 and P2.4.4) are used below this frequency when motorized potentiometer is selected x PROHIBIT FREQUENCIES Prohibit frequency area; Low limit Prohibit frequency area; High limit In some systems it may be necessary to avoid certain frequencies because of mechanical resonance problems. With these parameters it is possible to set limits for the "skip frequency" region. See Figure Figure Prohibit frequency area setting. 5-16

40 Acc/dec ramp speed scaling ratio between prohibit frequency limits Defines the acceleration/deceleration time when the output frequency is between the selected prohibit frequency range limits (parameters and 2.5.2). The ramping speed (selected acceleration/ deceleration time 1 or 2) is multiplied with this factor. For example, value 0.1 makes the acceleration time 10 times shorter than outside the prohibit frequency range limits. Figure Ramp speed scaling between prohibit frequencies Forward Slowdown Speed Setpoint Defines max forward speed of motor when slow down limit bit (P2.4.20:Fwd Slw Dwn Inp) is LOW Forward Low Speed Setpoint Defines forward speed of motor when fast speed input (P2.4.22:Fast Spd Inp) is LOW and DigIN:A.1 is HI Forward High Speed Setpoint Defines forward speed reference of motor under the below condition. DigIN:A.1 = HI DigIN:A.2 = LOW P2.4.22:Fast Spd Inp = HI P2.4.25:Ext Spd Inp = LOW Forward Extended Speed Setpoint Defines forward speed reference of motor into extended speed range under the below condition. DigIN:A.1 = HI DigIN:A.2 = LOW P2.4.22:Fast Spd Inp = HI P2.4.25:Ext Spd Inp = HI 5-17

41 Reverse Slowdown Speed Setpoint Defines max reverse speed of motor when slow down limit bit (P2.4.20:Fwd Slw Dwn Inp) is LOW Reverse Low Speed Setpoint Defines reverse speed of motor when fast speed input (P2.4.22:Fast Spd Inp) is LOW energized and DigIN:A.2 is HI Reverse High Speed Setpoint Defines reverse speed reference of motor under the below condition. DigIN:A.1 = LOW DigIN:A.2 = HI :Fast Spd Inp = HI P2.4.25:Ext Spd Inp = HI Reverse Extended Speed Setpoint Defines reverse speed reference of motor into extended speed range under the below condition. DigIN:A.1 = LOW DigIN:A.2 = HI P2.4.22:Fast Spd Inp = HI P2.4.25:Ext Spd Inp = HI Forward Slowdown Input Drive to operate at max FWD speed setpoint configured in P when this input LOW Reverse Slowdown Input Drive to operate at max REV speed setpoint configured in P when this input is LOW Fast Speed Input When bit is HI and either DigIN:A.1 or DigIN:A.2 are HI the drive will run at speed setpoints configured in either P for forward direction or P for reverse direction Extended Speed Current Limit Maximum value drive will produce current to as motor runs in extended speed range Extended Speed Input When bit is HI allows drive to operate in motor s extended speed range. High bit will also allow drive run motor to speed setpoint configured in either P for forward direction or P for reverse direction. 5-18

42 Load Float Bit ID HI bit will enable Load Float function. When enabled the drive will maintain motor speed set at parameter :Load Float Spd after the drive looses its run command and ramps down to load float speed. Drive will hold speed until either run is reenergized or Load Float Timer expires (P2.4.27) Load Float Time Constant Period of time the drive will have the motor maintain speed set at parameter :Load Float Spd. Period of time is in seconds Load Float Speed Speed of motor maintained when run when parameter :LD Float Bit ID is enabled, the drive s speed ramps down, and the run command is removed LF Trq Prv Spd Not used/future addition Reverse End Stop Input ID Disables drive run in reverse direction when LOW. Normally used for end of travel stop limits input Forward End Stop Input ID Disables drive run in the forward direction when LOW. Normally used for end of travel stop limits input Brake Close Timer After the run command is removed, the drive ramps the motor to zero, and the brakes are commanded to close, this timer makes the brake slip logic wait in order to allow the brakes to close before the logic starts monitoring the brake. Time is in seconds Enable Brake Slip Fault HI bit (1 = Yes) enables the open brake detection logic. After the drive has ramped the motor to zero, the run command is low, and the Brake Close Timer has expired, the open brake logic will compare V1.16:Encoder Speed to P2.4.34:Brake Slip Freq. If V1.16 exceeds P2.4.34, the logic will determine that the brake is open when it shouldn t. A detected open brake will cause the parameter programmed to P2.4.38:Brk Slip DOUT ID to toggle Brake Slip Frequency Speed setpoint that V1.16:Encoder Speed has to cross for the open brake logic to detect an open brake. 5-19

user's manual nx frequency converters beam pump application asfiff13

user's manual nx frequency converters beam pump application asfiff13 user's manual nx frequency converters beam pump application asfiff13 2 vacon Introduction INDEX 1. Introduction... 3 2. Commissioning... 4 2.1 Commissioning unbalanced load... 4 2.2 Commissioning balanced

More information

NX series Constant and variable torque Variable Speed Drives for induction motors

NX series Constant and variable torque Variable Speed Drives for induction motors Honeywell All in One Application Manual NX series Constant and variable torque Variable Speed Drives for induction motors Subject to changes without notice CONTENTS NX "All in One" APPLICATION MANUAL INDEX

More information

vacon nx all in one application manual ac drives Phone: Fax: Web: -

vacon nx all in one application manual ac drives Phone: Fax: Web:  - vacon nx ac drives all in one application manual vacon 1 INDEX Document ID:DPD00903A Revision release date: 30.3.2012 1. Basic Application...5 1.1. Introduction...5 1.1.1. Motor protection functions in

More information

NXL HVAC APPLICATION MANUAL Programming manual for NXL HVAC drives

NXL HVAC APPLICATION MANUAL Programming manual for NXL HVAC drives NXL HVAC APPLICATION MANUAL Programming manual for NXL HVAC drives Page 2 (68) Index Honeywell HVAC Application (Software [ALFIQ105] Ver.2.09) INDEX 1. INTRODUCTION... 3 2. CONTROL I/O... 3. HVAC APPLICATION

More information

user's manual nx frequency converters standard lift application asfiff08

user's manual nx frequency converters standard lift application asfiff08 user's manual nx frequency converters standard lift application asfiff08 2 vacon Vacon Standard Lift Application (Software ASFIFF08) INDEX Document code: UD0078L Date: 23.08.2007 1. Introduction... 3 2.

More information

vacon nx ac drives all in one application manual

vacon nx ac drives all in one application manual vacon nx ac drives all in one application manual PREFACE VACON 3 PREFACE Document ID: DPD00903F Date: 14.8.2017 Software code: Basic Application = ASFIFF01 Standard Application = ASFIFF02 Local/Remote

More information

Multi-purpose Control Application II

Multi-purpose Control Application II VACON CX /CXL/CXS FREQUENCY CONVERTERS Multi-purpose Control Application II USER'S MANUAL Subject to changes without notice Vacon Page 1 Multi-purpose Control Application II (par. 0.1 = 0) CONTENTS 1 General...

More information

SV9000 SVReady USER MANUAL CONTENTS OPEN SV9000 USER MANUAL. SV9000 Page 0-1

SV9000 SVReady USER MANUAL CONTENTS OPEN SV9000 USER MANUAL. SV9000 Page 0-1 SV9000 Page 0-1 SV9000 SVReady USER MANUAL CNTENTS A General...0-2 B Application selection...0-2 C Restoring default values of application parameters...0-2 D Language selection...0-2 1 Standard Control

More information

water solutions NX frequency converters applications manual

water solutions NX frequency converters applications manual HONEYWELL water solutions NX frequency converters applications manual INDEX 0. General... 2 0.1 Commissioning notes...3 0.2 Drive status indication... 3 0.3 Pressure/Level feedback...5 0.4 Function / terminal

More information

nx frequency converters shaft synchronization application apfiff11 user's manual

nx frequency converters shaft synchronization application apfiff11 user's manual nx frequency converters shaft synchronization application apfiff11 user's manual 2 vacon ABOUT THE SHAFT SYNCHRONIZATION APPLICATION MANUAL Congratulations for choosing the Smooth Control provided by Vacon

More information

vacon nxp arfiff30 user manual generator application ac drives

vacon nxp arfiff30 user manual generator application ac drives vacon nxp ac drives arfiff30 generator application user manual vacon 1 Vacon Generator application INDEX Document code: DPD01916A Software code: ARFIFF30V073 Date: 15.11.2016 VACON GENERATOR APPLICATION...

More information

vacon nx water solutions application manual ac drives

vacon nx water solutions application manual ac drives vacon nx ac drives water solutions application manual 13006.emf NOTE! You can download the English and French product manuals with applicable safety, warning and caution information from www.vacon.com/downloads.

More information

VACON CX/CXL/CXS FREQUENCY CONVERTERS. Lift Application USER'S MANUAL. Subject to changes without notice

VACON CX/CXL/CXS FREQUENCY CONVERTERS. Lift Application USER'S MANUAL. Subject to changes without notice VACON CX/CXL/CXS FREQUENCY CONVERTERS Lift Application USER'S MANUAL Subject to changes without notice Page 2(63) Lift Application Vacon Lift Application Par. 0.1 = 0 INDEX 1 LIFT APPLICATION... 3 1.1

More information

NX Series Inverters. HVAC Pocket Programming Guide

NX Series Inverters. HVAC Pocket Programming Guide NX Series Inverters HVAC Pocket Programming Guide HVAC Pocket Programming Guide HVAC Pocket Programming Guide / Contents This guide provides a single reference document for the user of NXL HVAC (product

More information

1. INTRODUCTION Fire Mode PID Application Parameter lists DESCRIPTION OF PARAMETERS... 8

1. INTRODUCTION Fire Mode PID Application Parameter lists DESCRIPTION OF PARAMETERS... 8 U S E R ' S M A N U A L NX F R E Q U E N C Y C O N V E R T E R S A D D O N P A G E S F O R T H E F I R E M O D E P I D A P P L I C A T I O N F O R S M O O T H C O N T R O L INDEX 1. INTRODUCTION... 3 2.

More information

VACON LIFT USER S MANUAL APSPFF29V144 (APSPFF29_RV9_EN_BM)

VACON LIFT USER S MANUAL APSPFF29V144 (APSPFF29_RV9_EN_BM) VACON LIFT USER S MANUAL APSPFF29V144 (APSPFF29_RV9_EN_BM) Page 2 Vacon Lift Application (Software APSPFF29) INDEX 1. INTRODUCTION...3 2. PROGRAMMING PRINCIPLE OF THE INPUT SIGNALS IN THE LIFT APPLICATION...4

More information

GS1 Parameter Summary Detailed Parameter Listings...4 9

GS1 Parameter Summary Detailed Parameter Listings...4 9 CHAPTER AC DRIVE 4 PARAMETERS Contents of this Chapter... GS1 Parameter Summary...............................4 2 Detailed Parameter Listings..............................4 9 Motor Parameters.........................................4

More information

HPVFP High Performance Full Function Vector Frequency Inverter

HPVFP High Performance Full Function Vector Frequency Inverter Advanced User Manual HPVFP High Performance Full Function Vector Frequency Inverter HP VER 1.00 1. HPVFP Parameter Set Overview...3 1.1. About this section...3 1.2. Parameter Structure Overview...3 1.3.

More information

vacon 100 flow ac drives application manual

vacon 100 flow ac drives application manual vacon 100 flow ac drives application manual vacon 1 TABLE OF CONTENTS Document: DPD01083A Version release date: 16.11.12 Corresponds to software package FW0159V121106.vcx 1. Vacon 100 FLOW - Quick Startup

More information

CHAPTER AC DRIVE PARAMETERS. In This Chapter...

CHAPTER AC DRIVE PARAMETERS. In This Chapter... CHAPTER AC DRIVE 4 PARAMETERS In This Chapter... GS2 Parameter Summary....................4 2 Detailed Parameter Listings.................4 11 Motor Parameters........................4 11 Ramp Parameters.........................4

More information

vacon nxp optcg user manual s2 option board selma application (apfien04) ac drives

vacon nxp optcg user manual s2 option board selma application (apfien04) ac drives vacon nxp ac drives optcg s2 option board selma application (apfien04) user manual 2 vacon index INDEX Document code: DPD00894A Date:17.01.2012 1. GENERAL... 4 2. INSTALLATION... 5 3. CONNECTIONS... 7

More information

safety Doc: DPD00714C, Released: vacon 1 ONLY A COMPETENT ELECTRICIAN IS ALLOWED TO CARRY OUT THE ELECTRICAL INSTALLATION! 1.

safety Doc: DPD00714C, Released: vacon 1 ONLY A COMPETENT ELECTRICIAN IS ALLOWED TO CARRY OUT THE ELECTRICAL INSTALLATION! 1. safety Doc: DPD00714C, Released: 10.28.2011 vacon 1 This quick guide includes the essential steps for easy installation and setup of your Vacon 10 frequency converter. Before commissioning your drive,

More information

1. Vacon Startup Startup Wizard PID Mini-Wizard Multi-pump mini-wizard... 5

1. Vacon Startup Startup Wizard PID Mini-Wizard Multi-pump mini-wizard... 5 vacon 100 hvac drives application manual vacon 0 INDEX Document: DPD0001C Version release date: 16..10 Corresponds to application package FW02000V019.vcx 1. Vacon 100 - Startup... 2 1.1 Startup Wizard...

More information

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection Quick Start Guide TECO F510 Inverter This guide is to assist you in installing and running the inverter and verify that it is functioning correctly for it s main and basic features. For detailed information

More information

Users Manual SM5 INVERTER. Subject to changes without notice December, 2001

Users Manual SM5 INVERTER. Subject to changes without notice December, 2001 Users Manual SM5 INVERTER Subject to changes without notice December, 2001 1 SM5 Contents 1. SAFETY... 3 1.1 Warnings...3 1.2 Safety Instructions...3 1.3 Earthing...4 1.4 Running The motor...4 2. RECEIVING...

More information

HITACHI. L100-M Series Inverter Quick Reference Guide. Hitachi Industrial Equipment Systems Co., Ltd. Single-phase Input 100V Class

HITACHI. L100-M Series Inverter Quick Reference Guide. Hitachi Industrial Equipment Systems Co., Ltd. Single-phase Input 100V Class HITACHI L1-M Series Inverter Quick Reference Guide Single-phase Input 1V Class Hitachi Industrial Equipment Systems Co., Ltd. Manual No. NB5741XD December 23 Caution: Be sure to read the L1 Inverter Manual

More information

vacon 100 hvac ac drives application manual

vacon 100 hvac ac drives application manual vacon 100 hvac ac drives application manual PREFACE VACON 3 PREFACE Document ID: DPD01696K Date: 11.04.2016 Software version: FW0065V032 ABOUT THIS MANUAL This manual is copyright of Vacon Ltd. All Rights

More information

SJ100 Series Inverter Quick Reference Guide. Single-phase Input 200V Class Three-phase Input 200V Class Three-phase Input 400V Class

SJ100 Series Inverter Quick Reference Guide. Single-phase Input 200V Class Three-phase Input 200V Class Three-phase Input 400V Class HITACHI SJ1 Series Inverter Quick Reference Guide Single-phase Input 2V Class Three-phase Input 2V Class Three-phase Input 4V Class Hitachi Industrial Equipment Systems Co., Ltd. Manual No. NB5821XD Dec.

More information

vacon nxs robust drive for heavy use

vacon nxs robust drive for heavy use vacon nxs robust drive for heavy use the reliable choice The Vacon is a compact AC drive in the power range of 0.7 560 kw and supply voltages of 208 690 V for heavy use in machines, buildings and all branches

More information

vacon 100 flow ac drives application manual

vacon 100 flow ac drives application manual vacon 100 flow ac drives application manual PREFACE VACON 3 PREFACE Document ID: DPD01083D Date: 15.10.2014 Software version: FW0159V010 ABOUT THIS MANUAL This manual is copyright of Vacon Plc. All Rights

More information

FUJI Inverter. Standard Specifications

FUJI Inverter. Standard Specifications FUJI Inverter o Standard Specifications Norminal applied motor The rated output of a general-purpose motor, stated in kw. That is used as a standard motor. Rated capacity The rating of an output capacity,

More information

6.9 Jump frequency - Avoiding frequency resonance

6.9 Jump frequency - Avoiding frequency resonance E581595.9 Jump frequency - Avoiding frequency resonance : Jump frequency : Jumping width Function Resonance due to the natural frequency of the mechanical system can be avoided by jumping the resonant

More information

TOSVERT TM VF-nC3 Parameter List

TOSVERT TM VF-nC3 Parameter List TOSVERT TM VF-nC Parameter List E658664 - Setting information * Please fill it in if necessary. Item Content Item Content Setting date / person Customer Application Application model Motor manufacturer

More information

Comp-AC. User s Manual for type ACS 140 frequency converters from 0.12 to 2.2 kw

Comp-AC. User s Manual for type ACS 140 frequency converters from 0.12 to 2.2 kw Comp-AC User s Manual for type ACS 140 frequency converters from 0.12 to 2.2 kw ACS 140 Frequency Converter User s Manual 3BFE 64273736 R0125 EN Effective: 8.3.2000 2000 ABB Industry Oy Safety Warning!

More information

Altivar 68 Telemecanique

Altivar 68 Telemecanique Altivar 68 Telemecanique Programming manual Variable speed drives for asynchronous motors Contents Installation recommendations 3 Control 7 A - Display of references and actual values and configuration

More information

vacon 100 ac drives application manual

vacon 100 ac drives application manual vacon 100 ac drives application manual vacon 0 INDEX Document: DPD00927D Version release date: 5.5.12 Corresponds to software package FW0072V00.vcx 1. Vacon 100 - Startup... 2 1.1 Startup Wizard... 2

More information

Hitachi P1 Closed Loop Hoist Basic Instruc on Manual

Hitachi P1 Closed Loop Hoist Basic Instruc on Manual Hitachi P1 Closed Loop Hoist Basic Instruc on Manual DH Firmware V.18 DETROIT HOIST AND CRANE LLC, CO. 6650 STERLING DRIVE NORTH STERLING HEIGHTS MICHIGAN 48312 Introduction This manual only applies to

More information

CHAPTER 8 PARAMETER SUMMARY

CHAPTER 8 PARAMETER SUMMARY CHAPTER PARAMETER SUMMARY Group 0: System Parameter VFD-V Series 00-00 Identity Code Based on the model type 00-01 Rated Current Display 00-02 Parameter Reset 00-03 00-04 Star-up Display of the Drive Definitions

More information

THYFREC-VT110S 200V 1PH System 0.4 to 2.2kW 400V 3PH System 0.75 to 2.2kW QUICK START GUIDE

THYFREC-VT110S 200V 1PH System 0.4 to 2.2kW 400V 3PH System 0.75 to 2.2kW QUICK START GUIDE MEIDEN AC SPEED CONTROL EQUIPMENT THYFREC-VT110S 200V 1PH System 0.4 to 2.2kW 400V 3PH System 0.75 to 2.2kW QUICK START GUIDE NOTICE 1. Read this manual thoroughly before using the VT110S, and store in

More information

Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide

Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide The Invertek Optidrive E3 Frequency Inverter range is available to order from inverterdrive.com This guide is intended to complement

More information

Operating Instructions

Operating Instructions 4XH35QB151210 Small General Frequency Converter Operating Instructions 220V 0.75KW 5.5KW 400V 0.75KW 15KW Please read the instruction carefully and understand the contents so that it can be installed and

More information

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual INDEX A AC Drive Cover: 1 6 Dimensions: 2 4 External Parts and Labels: 1 6 Heat Sink Fins: 1 6 Input Mode Switch (Sink/Source): 1 6 Introduction to DuraPulse GS3 AC drive: 1 3 Keypad: 1 6 Model Number

More information

Before you operate the inverter, the parameters that you must first program are the basic parameters.

Before you operate the inverter, the parameters that you must first program are the basic parameters. . Main parameters Before you operate the inverter, the parameters that you must first program are the basic parameters..1 Searching for changes using the history function () : History function History

More information

for Speed Control of 0.75 to 7.5 HP Induction Motors Supply Voltage 208 to 240 V 380 to 480 V Users Manual

for Speed Control of 0.75 to 7.5 HP Induction Motors Supply Voltage 208 to 240 V 380 to 480 V Users Manual ACS 200 AC Drives for Speed Control of 0.75 to 7.5 HP Induction Motors Supply Voltage 208 to 240 V 380 to 480 V Users Manual ACS200-US-04B Effective 12/1/94 Supersedes 12/1/ 93 . ACS 200 AC Drives for

More information

Frequency Converters for Speed Control of 0.55 to 4.0 kw Squirrel Cage Motors Supply Voltage 208 to 240 V 380 to 480 V User s Manual

Frequency Converters for Speed Control of 0.55 to 4.0 kw Squirrel Cage Motors Supply Voltage 208 to 240 V 380 to 480 V User s Manual ACS 200 Frequency Converters for Speed Control of 0.55 to 4.0 kw Squirrel Cage Motors Supply Voltage 208 to 240 V 380 to 480 V User s Manual Keep this User's Manual within easy reach. Warning symbols For

More information

vacon 10 ac drives quick guide

vacon 10 ac drives quick guide vacon 10 ac drives quick guide NOTE! You can download the English and French product manuals with applicable safety, warning and caution information from www.vacon.com/downloads. REMARQUE Vous pouvez télécharger

More information

ACH550 HVAC Drive Submittal

ACH550 HVAC Drive Submittal ACH550 HVAC Drive Submittal DATE: PROJECT NAME: CONTRACTOR: ENGINEER: SUBMITTED BY: SUBMITTALS FOR: RECORD APPROVAL (Return a copy of the approved submittal) ACH550 Features Standard Features UL and cul

More information

The GS1 Digital Keypad LED Display Function Keys Displaying the Status of the GS1 AC Drive Programming the GS1 AC Drive...

The GS1 Digital Keypad LED Display Function Keys Displaying the Status of the GS1 AC Drive Programming the GS1 AC Drive... CHAPTER KEYPAD OPERATION 3 AND QUICKSTART Contents of this Chapter... The GS1 Digital Keypad................................3 2 LED Display..............................................3 2 Function Keys............................................3

More information

S11 Adjustable Speed Drive Engineering Specification

S11 Adjustable Speed Drive Engineering Specification PART 1 - GENERAL 1.0 Scope This specification shall cover Toshiba S11 AC Variable Frequency Drives, 6 pulse for 3- phase 200-240VAC, 380-500VAC and single phase 200V to 240VAC. 1.1 References A. National

More information

AQUAVAR CPC. Modbus Communications (Software Version 204 and later)* INSTRUCTION MANUAL ADAQCPC R1

AQUAVAR CPC. Modbus Communications (Software Version 204 and later)* INSTRUCTION MANUAL ADAQCPC R1 INSTRUCTION MANUAL ADAQCPC R1 AQUAVAR CPC Modbus Communications (Software Version 204 and later)* ADDENDUM TO THE INSTALLATION AND OPERATION MANUAL (IM167) * Aquavar CPC units with software 204 and later

More information

VF-nC1 Adjustable Speed Drive Engineering Specification

VF-nC1 Adjustable Speed Drive Engineering Specification PART 1 - GENERAL 1.0 Scope This specification shall cover Toshiba VF-nC1 AC Variable Frequency Drives, 6 pulse for 100V single-phase 0.1 to 0.75kW, 200V single-phase 0.2 to 2.2kW and 200V threephase 0.1

More information

THYFREC-VT210S 400V System 37 to 315kW (C/T) 400V System 45 to 370kW (V/T) QUICK START GUIDE

THYFREC-VT210S 400V System 37 to 315kW (C/T) 400V System 45 to 370kW (V/T) QUICK START GUIDE MEIDEN AC SPEED CONTROL EQUIPMENT THYFREC-VT210S 400V System 37 to 315kW (C/T) 400V System 45 to 370kW (V/T) QUICK START GUIDE NOTICE 1. Read this manual thoroughly before using the VT210S, and store in

More information

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB DF5-... Frequency Inverters 1 st published 22, edition 02/02 Moeller GmbH, 53105 Bonn Author: Holger Friedrich Editor: Michael Kämper Translator: Dominik Kreuzer All brand and product names are trademarks

More information

[ 4 ] Using pulse train input (F01 = 12)

[ 4 ] Using pulse train input (F01 = 12) [ 4 ] Using pulse train input (F01 = 12) Selecting the pulse train input format (d59) A pulse train in the format selected by the function code d59 can give a frequency command to the inverter. Three types

More information

VS-616G5 Series (Revision F) Programming Manual. Constant Torque Inverter with Adaptive Vector Control (AVC )

VS-616G5 Series (Revision F) Programming Manual. Constant Torque Inverter with Adaptive Vector Control (AVC ) VS-616G5 Series (Revision F) Programming Manual Constant Torque Inverter with Adaptive Control (AVC ) ! WARNING PRECAUTIONS NOTICE 1) Only turn ON the input power supply after replacing the front cover.

More information

Document code: DPD00343A Edited:

Document code: DPD00343A Edited: vacon 10 ac drives vacon 10 pfc user manual Document code: DPD00343A Edited: 29.4.2010 1.Safety 4 1.1 Warnings 4 1.2 Safety instructions 5 1.3 Grounding and ground fault protection 5 1.4 Before running

More information

Control chain diagrams

Control chain diagrams Control chain diagrams 565 Control chain diagrams What this chapter contains The chapter presents the reference chains of the drive. The control chain diagrams can be used to trace how parameters interact

More information

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps. VFD - D700 Series Specifications The latest low-cost variable speed control solution for centrifugal pumps. Built-in PID Control to maintain pressure, flow, measured value, and much more 125% overload

More information

CHAPTER KEYPAD OPERATION AND QUICKSTART. In This Chapter... The GS2 Digital Keypad GS2 Quickstart...3 6

CHAPTER KEYPAD OPERATION AND QUICKSTART. In This Chapter... The GS2 Digital Keypad GS2 Quickstart...3 6 CHAPTER KEYPAD OPERATION 3 AND QUICKSTART In This Chapter... The GS2 Digital Keypad.....................3 2 LED Display.........................................3 2 LED Indicators.......................................3

More information

Multi-function, Compact Inverters. 3G3MV Series

Multi-function, Compact Inverters. 3G3MV Series Multi-function, Compact Inverters 3G3MV Series There has been a great demand for inverters with more functions and easier motor control than conventional i OMRON's powerful, compact 3G3MV Series with versat

More information

3. Be aware of the ambient temperature. Use the unit within the specified ambient temperature only.

3. Be aware of the ambient temperature. Use the unit within the specified ambient temperature only. This document is a short guide to how to connect, do the configuration and start the unit in the easiest way. Refer to the Instruction Manual IMAE-01, appropriate revision of Axpert-Eazy Series AC Drive

More information

D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL

D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL D SERIES LM16 COMPACT DRIVE V/f and SLV CONTROL LM16 COMPACT DRIVE V/f and SLV CONTROL 1 2 SERIES 1 2 page 4 page 6 Introduction Fields of application 3 page 7 4 page 8 Designation Product offer 5 6 page

More information

Vacon 100 Flow Course

Vacon 100 Flow Course 09-01-2018 Version 18.08F Sw:FW0159V014 Vacon 100 Flow Course Version 18.08F G:\Data\Iedereen\cursussen\Frequentieregelaars\Vacon\Vacon 100 Flow versie 18.08-eng.doc Vacon 100 Flow page1 Index Index...

More information

PumpSmart Commissioning Process

PumpSmart Commissioning Process PumpSmart Commissioning Process 1. Complete the PumpSmart Warranty Registration form. The warrantee registration is our method for determining if an installation has been commissioned properly and to identify

More information

VFS11 Parameter List for up to CPU version 105

VFS11 Parameter List for up to CPU version 105 E65824 VFS Parameter List for up to CPU version 5 Setting Date Customer End user Application Application No/Serial No Inverter s Type-Form Quantity Inverter s Serial No Motor s capacity If user s value

More information

CHAPTER 8 SUMMARY OF PARAMETER SETTINGS

CHAPTER 8 SUMMARY OF PARAMETER SETTINGS CHAPTER 8 SUMMARY OF PARAMETER SETTINGS VFD-S Series!: The parameter can be set during operation, *: Twice the value for 460V class. Group 0 User Parameters Parameters Explanation s 0-00 Identity Code

More information

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters.

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters. ~ ~ SX High performance Vector Control IP54 full range. Compact design & Robustness Built-in Filter according to C3 Class Built-in Fusses (From 200 kw) Safety according EN13849-1 and EN62061 standards

More information

E3 Adjustable Speed Drive Engineering Specification

E3 Adjustable Speed Drive Engineering Specification E3 Adjustable Speed Drive Engineering Specification PART 1 - GENERAL 1.0 Scope This specification shall cover Toshiba E3 AC Variable Frequency Drives, 6 pulse for 230V and 460V. 1.1 References A. National

More information

General Specifications FECA-TE /2010. Phone: Fax: Web:

General Specifications FECA-TE /2010. Phone: Fax: Web: General Specifications FECA-TE-117 06/2010 1. Standard Specifications 1) Three-phase 230V series Output ratings Input ratings Braking Item Specifications Type (FRN C1S-2U) F12 F25 F50 001 002 003 005 Nominal

More information

fire mode pid application asfiff11

fire mode pid application asfiff11 user's manual nx frequency converters fire mode pid application asfiff11 4 2 vacon INTRODUCTION INDEX 1. INTRODUCTION...3 2. Fire Mode PID Application Parameter lists...4 2.1 Monitoring values (Control

More information

AV-300i Specifications. Saftronics Inc. VG10 Product Specifications VG10. Dynamic Vector Drive

AV-300i Specifications. Saftronics Inc.   VG10 Product Specifications VG10. Dynamic Vector Drive Saftronics Inc. www.saftronics.com TM AV-300i Specifications VG10 Product Specifications VG10 Dynamic Vector Drive 1 Category Item Description Nominal Motor 230 VAC, 3 Phase 1/4 Hp to 125 Hp 460 VAC, 3

More information

M-Max series drives. The next generation of OEM drives

M-Max series drives. The next generation of OEM drives M-Max series drives The next generation of OEM drives Continue learning more about Eaton drives, services and solutions. Please visit us at: www.eaton.com/drives CD CONTENTS MaxConnect MaxLoader Firmware

More information

Servo Indexer Reference Guide

Servo Indexer Reference Guide Servo Indexer Reference Guide Generation 2 - Released 1/08 Table of Contents General Description...... 3 Installation...... 4 Getting Started (Quick Start)....... 5 Jog Functions..... 8 Home Utilities......

More information

KBDA SERIES STANDARD FEATURES DESCRIPTION PERFORMANCE FEATURES PROTECTION FEATURES

KBDA SERIES STANDARD FEATURES DESCRIPTION PERFORMANCE FEATURES PROTECTION FEATURES KBDA SERIES ADJUSTABLE FREQUENCY DRIVES FOR 3-PHASE AC MOTORS NEMA-4X / IP-65 Washdown and Watertight for Indoor and Outdoor use MULTI-FUNCTION KEYPAD WITH 4-DIGIT LED DISPLAY Simplified Group Programming

More information

AV-300i Specifications. GE Industrial Systems. Product Specifications. A New Concept in Automation. AV-300i

AV-300i Specifications. GE Industrial Systems. Product Specifications. A New Concept in Automation. AV-300i GE Industrial Systems Product Specifications AV-300i A New Concept in Automation. TM 1 General Item Description Nominal Motor 230V, 3 Phase 15 Hp to 100 Hp 460V, 3 Phase 3/4 Hp to 200 Hp Enclosure, Standard

More information

SX (690 V) System configuration

SX (690 V) System configuration SX (690 V) High performance Vector Control IP54 full range Compact design & Robustness Built-in Filter according to C3 Class Built-in Fuses (From 200 kw) Safety according EN13849-1 and EN62061 standards

More information

CHAPTER 5 DESCRIPTION OF PARAMETER SETTINGS

CHAPTER 5 DESCRIPTION OF PARAMETER SETTINGS CHAPTER DESCRIPTION OF PARAMETER SETTINGS.1 Group 0: User Parameters 0-00 Identity Code of AC Drive Factory setting: d# Settings None V HP 1/4 1/2 1 2 3 11V/230V d0 d2 d4 d6 d8 460V -- -- -- d3 d d7 d9

More information

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB. For Immediate Delivery call KMParts.com at (866)

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB. For Immediate Delivery call KMParts.com at (866) DF5-... Frequency Inverters 1 st published 22, edition 02/02 Moeller GmbH, 53105 Bonn Author: Holger Friedrich Editor: Michael Kämper Translator: Dominik Kreuzer All brand and product names are trademarks

More information

Honeywell. User Manual. SmartVFD COMPACT. Variable Frequency Drives for Constant and Variable Torque Applications

Honeywell. User Manual. SmartVFD COMPACT. Variable Frequency Drives for Constant and Variable Torque Applications Ho Honeywell User Manual SmartVFD COMPACT Variable Frequency Drives for Constant and Variable Torque Applications Honeywell 1 User s Manual Index 1. SAFETY...3 1.1 Warnings...3 1.2 Safety instructions...5

More information

VFS9 Parameter List for Version110 or later

VFS9 Parameter List for Version110 or later VFS9 Parameter List for Version110 or later Setting Date Customer End user Application Application /Serial Inverter s Type-Form Quantity Inverter s Serial Motor s capacity If user s value is same as shipping

More information

SX (400 V) System configuration

SX (400 V) System configuration ~ ~ SX (400 V) High performance Vector Control IP54 full range. Compact design & Robustness Built-in Filter according to C3 Class Built-in Fuses (From 200 kw) Safety according EN13849-1 and EN62061 standards

More information

BACnet- MS/TP COMMUNICATION V

BACnet- MS/TP COMMUNICATION V - MS/TP COMMUNICATION V1.00.08.17 11.1 Introduction The VFD can be controlled and monitored through the BACnet MS/TP protocol over an RS-485 connection. The VFD operates as an MS/TP master device, which

More information

ADTECH Solar inverter

ADTECH Solar inverter ADTECH Solar inverter 1. Product description Thank you very much for your selection of special solar inverter launched by ADTECH (SHENZHEN) TECHNOLOGY CO., LTD. Solar energy special inverter is designed

More information

ROLL TO ROLL FUNCTION MANUAL FR-A (0.4K)-04750(90K)-R2R FR-A (0.4K)-06830(280K)-R2R FR-A (315K)-12120(500K)-R2R

ROLL TO ROLL FUNCTION MANUAL FR-A (0.4K)-04750(90K)-R2R FR-A (0.4K)-06830(280K)-R2R FR-A (315K)-12120(500K)-R2R INVERTER ROLL TO ROLL FUNCTION MANUAL FR-A820-00046(0.4K)-04750(90K)-R2R FR-A840-00023(0.4K)-06830(280K)-R2R FR-A842-07700(315K)-12120(500K)-R2R Roll to Roll Function The FR-A800-R2R inverter has dedicated

More information

1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control.

1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control. Section 16680 VARIABLE SPEED DRIVE SYSTEMS OR AFD Part I - GENERAL I.01 Description A. This specification is to cover a complete adjustable frequency motor drive consisting of a pulse width modulated (PWM)

More information

Drive IT Low Voltage Drives. User's Guide for type ACS50 AC Drives from 0.18 to 0.75 kw

Drive IT Low Voltage Drives. User's Guide for type ACS50 AC Drives from 0.18 to 0.75 kw Drive IT Low Voltage Drives User's Guide for type ACS50 AC Drives from 0.18 to 0.75 kw ACS50 User s Guides in other languages can be found from internet: http://www.abb.com. Enter ACS50 UG into the Search

More information

SX (400V) System configuration

SX (400V) System configuration ~ ~ SX (400V) High performance Vector Control IP54 full range. Compact design & Robustness Built-in Filter according to C3 Class Built-in Fusses (From 200 kw) Safety according EN13849-1 and EN62061 standards

More information

MD310 Quick Start Manual. General-Purpose AC Drive

MD310 Quick Start Manual. General-Purpose AC Drive MD310 Quick Start Manual General-Purpose AC Drive ersion 0.1 Dated 14 th OCT, 2013 CONTENTS CHAPTER 1 PRODUCT INFORMATION... 1 1.1 Designation... 1 1.2 Nameplate... 1 1.3 General Specifications... 2 CHAPTER

More information

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H018F1 variable speed drive ATV kW hp V - 1ph Characteristics variable speed drive ATV12-0.18kW - 0.25hp - 100..120V - 1ph Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly style Component

More information

Warning!! 2. The drive contains high voltage that can cause electric shock resulting in personal injury or loss of life.

Warning!! 2. The drive contains high voltage that can cause electric shock resulting in personal injury or loss of life. ! Warning!! 1. Please read this manual completely before installing the drive. 2. The drive contains high voltage that can cause electric shock resulting in personal injury or loss of life. 3. Be sure

More information

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13 Index A A Group functions 3 9 AC reactors 5 3 Acceleration 1 15, 3 8 characteristic curves 3 26 second function 3 24 two-stage 4 19 Acceleration stop function 3 21 Access levels 3 5, 3 36, 4 25 Access

More information

ADJUSTABLE SPEED DRIVES. AS1 Drive

ADJUSTABLE SPEED DRIVES. AS1 Drive ADJUSTABLE SPEED DRIVES AS1 Drive Toshiba s New ASD Product Line The AS1 drive builds on Toshiba s history of supplying powerful, reliable, and versatile drives. We have combined our best drive features

More information

Inverter Drive /Vector Drive Motors & Controls

Inverter Drive /Vector Drive Motors & Controls H2 Inverter/ Encoderless Vector Inverter Drive /Vector Drive & Controls 3/4 thru 50 180-264 VAC 3 Phase - 50/60 Hz 3/4 thru 60 340-528 VAC 3 Phase - 50/60 Hz 3/4 thru 60 515-660 VAC 3 Phase - 60 Hz HVAC

More information

Enhanced PID for Air Compressors F7 Drive Software Technical Manual

Enhanced PID for Air Compressors F7 Drive Software Technical Manual Software Number: VSF11020X, Drive Models: CIMR-F7UXXXXXX-096 Document Number: TM.F7SW.096, Date: 08/01/05, Rev: 05-08 Enhanced PID for Air Compressors F7 Drive Software Technical Manual This document is

More information

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz TAC ATV8, IP55 Variable Speed Drives for Asynchronous Motors. -phase. 80/460 V, 50-60 Hz E-60-24 24 May 2004 ATV 8 IP55 drives are specifically designed for pump and fan applications powered by a three-phase

More information

CHAPTER 5 DESCRIPTION OF PARAMETER SETTINGS

CHAPTER 5 DESCRIPTION OF PARAMETER SETTINGS CHAPTER DESCRIPTION OF PARAMETER SETTINGS.1 Group 0: System Parameter VFD-V Series 00-00 Identity Code Factory setting Read Only Settings Based on the model type 00-01 Rated Current Display Factory setting

More information

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink Characteristics variable speed drive ATV12-0.37kW - 0.55hp - 100..120V - 1ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application

More information

Programming Guide. VLT Micro Drive FC 51

Programming Guide. VLT Micro Drive FC 51 Programming Guide VLT Micro Drive FC 51 VLT Micro Drive FC 51 Contents Contents 1. Safety 3 Safety Instructions 3 Software Version and Approvals 3 General Warning 3 Avoid unintended Start Before Commencing

More information

Copyright 2014 YASKAWA ELECTRIC CORPORATION All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or

Copyright 2014 YASKAWA ELECTRIC CORPORATION All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or Copyright 2014 YASKAWA ELECTRIC CORPORATION All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, mechanical, electronic,

More information

160 Series C Custom Firmware

160 Series C Custom Firmware Instructions 160 Series C Custom Firmware S02 Option FRN 7.06 C004 Introduction The S02 option extends the kw/hp ratings of the standard 160 drive. In addition, the following function changes have been

More information