Communication. Features. Device variant. Copyright 2016, Builder: , Time: 05:45:24

Size: px
Start display at page:

Download "Communication. Features. Device variant. Copyright 2016, Builder: , Time: 05:45:24"

Transcription

1 Version V Release date Copyright 216, Builder: , Time: 5:45:24 SA Vendor ID Device ID Vendor name Vendor text Vendor URL 31 / x136 - s: 1 54 / x1 x36 54 / x21c - s: 2 28 / x x2 x1c ifm electnic gmbh Communication IO-Link revision Bit rate Minimum cycle time SIO mode supported Features Block parametrization Data storage V1.1 COM2 3. ms Yes Yes Yes Device variant SA53_LIQU SA54_LIQU SA2_LIQU SA5_LIQU SA41_LIQU SA43_LIQU Flow monitor, absolutely (Liquids), , IO-Link, CRN, GL, culus (Limited Voltage / Current), M18 x 1, 5 Flow monitor, absolutely (Liquids), , IO-Link, culus (Limited Voltage / Current), M18 x 1, 5 Flow monitor, absolutely (Liquids), , IO-Link, culus (Limited Voltage / Current), G 1/2" Flow monitor, absolutely (Liquids), , IO-Link, culus (Limited Voltage / Current), M18 x 1, 5 Flow monitor, absolutely (Liquids), , IO-Link, culus (Limited Voltage / Current), Ø 8 mm Flow monitor, absolutely (Liquids), , IO-Link, culus (Limited Voltage / Current), Ø 8 mm Page 1

2 Pcess data (Pcess data input) Total bit length = 32 Bit offset Bit length Flow Current flow to 36 (3276) OL.1 Temperature Current temperature to 124 (-8184) UL (8184) OL.1 OUT2 Status depends on [OU2] 1 (false) inactive (true) active OUT1 Status depends on [OU1] (false) inactive (true) active Page 2

3 Standard Command 2 U wo (13) Restore Factory Settings (161) Reset [Hi.F] and [Lo.F] memory (162) Reset [Lo.F] memory (163) Reset [Hi.F] memory (165) Reset [Hi.T] and [Lo.T] memory (166) Reset [Lo.T] memory (167) Reset [Hi.T] memory (184) Set MEdI SET_MEDI_H2O (185) Set MEdI SET_MEDI_GLYC (186) Set MEdI SET_MEDI_OIL1 (187) Set MEdI SET_MEDI_OIL2 (24) IO-Link 1.1 system test command 24, Event 8DFE appears (241) IO-Link 1.1 system test command 241, Event 8DFE disappears Page 3

4 Standard Command 2 U wo (242) IO-Link 1.1 system test command 242, Event 8DFF appears (243) IO-Link 1.1 system test command 243, Event 8DFF disappears (255) Command without effect, for internal use only Device Locks 12 RecordT Data Storage bitoffs 1 (false) (false) Unlocked (true) Locked Local User Interface bitoffs 3 (false) (false) Unlocked (true) Locked Vendor 16 max 19 ifm electnic gmbh Vendor Text 17 max 11 Pduct 18 max 11 Pduct ID 19 max 6 Pduct Text 2 max 24 Flow Sensor Calorimetric Serial Number 21 max 12 Page 4

5 Hardware Version 22 max 2 Firmware Version 23 max 5 Application Specific Tag 24 max 32 *** Device Status 36 U () Device is OK () Device is OK (1) Maintenance required (2) Out of specification (3) Functional check (4) Failure 5 to 255 (Reserved) Detailed Device Status h P-n Output polarity for the switching outputs 5 U () PnP () PnP (1) npn dap Damping of the measured signal 51 U 6 to 5.1 s SEL2 Selection of the measurand for the evaluation via [OUT 2] 521 U (1) FLOW (1) FLOW (2) TEMP Page 5

6 FOU1 [OUT 1] behaviour in case of fault 531 U (4) OFF (1) OU (2) On (4) OFF FOU2 [OUT 2] behaviour in case of fault 532 U (4) OFF (1) OU (2) On (4) OFF BitCoded_ActiveEvents Bit mask for current pending events 545 RecordT 32 Bit Bit_31 Bit 31 indicates the assigned bitoffs 31 () noev () noev (1) x8dff Bit_3 Bit 3 indicates the assigned bitoffs 3 () noev () noev (1) x8dfe Bit_16 Bit 16 indicates the assigned bitoffs 16 () noev () noev (1) x8cc3 Bit_9 Bit 9 indicates the assigned bitoffs 9 () noev () noev (1) x8c3 Bit_8 Bit 8 indicates the assigned bitoffs 8 () noev () noev (1) x8c1 Bit_3 Bit 3 indicates the assigned bitoffs 3 () noev () noev (1) x6321 Bit_2 Bit 2 indicates the assigned bitoffs 2 () noev () noev (1) x771 Bit_1 Bit 1 indicates the assigned bitoffs 1 () noev () noev (1) x632 Page 6

7 BitCoded_ActiveEvents Bit mask for current pending events 545 RecordT 32 Bit Bit_ Bit indicates the assigned bitoffs () noev () noev (1) x5 ParaConfigFaultCollection Displays the wngly set parameters 546 Loc [Loc] locks the local user interface to prevent unintentional changes, [Loc] is resettable at the device 55 U (1) uloc () Loc (1) uloc uni Selection of the physical unit 551 U (1) l/min () (1) l/min (2) m³/h dis Display settings 552 RecordT Display On / OFF bitoffs 7 (false) On (false) On (true) OFF Display orientation bitoffs 6 (false) Not tated (false) Not tated (true) Rotated 18 Update rate bitoffs U 6 Bit (2) d2 / medium (1) d1 / fast (2) d2 / medium (4) d3 / slow SELd Selection of measurement on the sensor display 553 RecordT Displayed measurement bitoffs U 15 Bit (1) FLOW (1) FLOW (2) TEMP Page 7

8 colr Assignment of the display colours 'red' and 'green' within the measuring range 554 U (2) red / Display colour red (independent of the measured value) (2) red / Display colour red (independent of the measured value) (3) GrEn / Display colour green (independent of the measured value) (4) r1ou / Display colour red when OUT1 switches (5) G1ou / Display colour green when OUT1 switches (6) r2ou / Display colour red when OUT2 switches (7) G2ou / Display colour green when OUT2 switches Hi.F Maximum memory value for flow 56 ().1 to 36 (3276) OL Lo.F Minimum memory value for flow 561 ().1 to 36 Page 8

9 Lo.F Minimum memory value for flow 561 () (3276) OL.1 Hi.T Maximum memory value for temperature 562 ().1-44 to 124 (-8184) UL (8184) OL Lo.T Minimum memory value for temperature 563 ().1-44 to 124 (-8184) UL (8184) OL ou1 Output configuration [OUT 1] 58 U (3) Hno / Hysteresis fct normally open (3) Hno / Hysteresis fct normally open (4) Hnc / Hysteresis fct normally closed (5) Fno / Window fct normally open (6) Fnc / Window fct normally closed (17) FRQ / Frequency output ds1 Switching delay for [OUT 1] 581 U to 6.1 s dr1 Reset delay for [OUT 1] 582 U to 6.1 s Page 9

10 SP_FH1_FLOW Switch point 1 / Flow, [SP1] 583 must be greater than [rp1]. Please take into account the current [rp1] value. [SP1] will be refused if below [rp1]. [SP] = [FH] and [rp] = [FL] if [OU1] = Fno, Fnc 6 18 to 3.1 rp_fl1_flow Reset point 1 / Flow, [rp1] 584 must be smaller than [SP1]. Please take into account the current [SP1] value.i[rp1] will be refused if above [SP1]. [rp] = [FL] and [SP] = [FH] if [OU1] = Fno, Fnc 46 4 to ou2 Output configuration [OUT 2] 59 U (1) I / Analog signal 4 2 ma (3) Hno / Hysteresis fct normally open (4) Hnc / Hysteresis fct normally closed (5) Fno / Window fct normally open (6) Fnc / Window fct normally closed (17) FRQ / Frequency output (1) I / Analog signal 4 2 ma ds2 Switching delay for [OUT 2] 591 U to 6.1 s dr2 Reset delay for [OUT 2] 592 U to 6.1 s Page 1

11 SP_FH2_FLOW Switch point 2 / Flow, [SP2] 593 must be greater than [rp2]. Please take into account the current [rp2] value. [SP2] will be refused if below [rp2]. [SP] = [FH] and [rp] = [FL] if [OU2] = Fno, Fnc to 3.1 rp_fl2_flow Reset point 2 / Flow, [rp2] 594 must be smaller than [SP2]. Please take into account the current [SP2] value.i[rp2] will be refused if above [SP2]. [rp] = [FL] and [SP] = [FH] if [OU2] = Fno, Fnc 16 4 to SP_FH2_TEMP Switch point 2 / Temperature, 595 [SP2] must be greater than [rp2]. Please take into account the current [rp2] value. [SP2] will be refused if below [rp2]. [SP] = [FH] and [rp] = [FL] if [OU2] = Fno, Fnc to 1.1 rp_fl2_temp Reset point 2 / Temperature, 596 [rp2] must be smaller than [SP2]. Please take into account the current [SP2] value.i[rp2] will be refused if above [SP2]. [rp] = [FL] and [SP] = [FH] if [OU2] = Fno, Fnc 26-2 to 98.1 ASP2_FLOW Analogue start point 2 / Flow. [ASP2] must be smaller than [AEP2]. Please take into account the current [AEP2]. For info on the minimum hysteresis [AEP2]-[ASP2] 63 to Page 11

12 please refer to the operating instructions AEP2_FLOW Analogue end point 2 / Flow. 631 [AEP2] must be greater than [ASP2]. Please take into account the current [ASP2]. For info on the min hysteresis [AEP2]-[ASP2] please refer to the operating instructions 3 58 to 3.1 ASP2_TEMP Analogue start point 2 / 632 Temperature. [ASP2] must be smaller than [AEP2]. Please take into account the current [AEP2]. For info on the minimum hysteresis [AEP2]-[ASP2] please refer to the operating instructions -2-2 to 76.1 AEP2_TEMP Analogue end point 2 / 633 Temperature. [AEP2] must be greater than [ASP2]. Please take into account the current [ASP2]. For info on the min hysteresis [AEP2]-[ASP2] please refer to the operating instructions 1 4 to 1.1 MEdI Current set medium 686 U () H2O () H2O (1) GLYC (2) OIL.1 (3) OIL.2 ModE Current set operating mode 689 U (1) LIQU Page 12

13 ModE Current set operating mode 689 U (1) LIQU () REL (1) LIQU (2) GAS FEP1_FLOW Flow on [OUT1] at [FrP1] to 3.1 FEP2_FLOW Flow on [OUT2] at [FrP2] to 3.1 FSP2_TEMP Temperature on [OUT2] at Hz to 76.1 FEP2_TEMP Temperature on [OUT2] at [FrP2] to 1.1 FrP1 Absolute frequency maximum 76 for [OUT 1] 1 1 to 1 1 Hz FrP2 Absolute frequency maximum 765 for [OUT 2] 1 1 to 1 1 Hz dia Diameter of pipe 37 U 5 15 to 4 1 mm CGA Calibration gain to 14 1 % VolFlow Current volume flow 39 Float32T to 1 1 l/min VolFlow.Max Peak volume flow 31 Float32T to 1 1 l/min TipVelocity Flow velocity at the sensor tip 313 to 2.1 Events Code Type 248 d / 5 h Device hardware fault Err Device Exchange d / 63 2 h Parameter err Err Check data sheet and values d / h Parameter missing Err Check data sheet Page 13

14 Events Code Type 348 d / 77 1 h Short circuit Err Check installation d / 8C 1 h Pcess variable range over-run Warning Pcess data uncertain. Note: This Event will not be transmitted via IO-Link Event mechanism. It is only available by reading 37 (DetailedDeviceStatus) oder 545 (BitCoded_ActiveEvents) d / 8C 3 h Pcess variable range under-run Warning Pcess data uncertain. Note: This Event will not be transmitted via IO-Link Event mechanism. It is only available by reading 37 (DetailedDeviceStatus) oder 545 (BitCoded_ActiveEvents) 3635 d / 8C C3 h Display function failure Warning Replace device 3635 d / 8D FE h Test Event 1 Warning Event appears by setting index 2 to value 24, Event disappears by setting index 2 to value d / 8D FF h Test Event 2 Warning Event appears by setting index 2 to value 242, Event disappears by setting index 2 to value 243 Err types Err code d / 8 h d / 8 11 h d / 8 12 h 328 d / 8 2 h 3283 d / 8 23 h d / 8 3 h d / 8 33 h 3282 d / 8 34 h d / 8 35 h d / 8 36 h d / 8 4 h d / 8 41 h d / 8 82 h Device application err - no details not available not available Service temporarily not available denied Parameter value out of range Parameter length overrun Parameter length underrun Function not available Function temporarily unavailable Invalid parameter set Inconsistent parameter set Application not ready Service has been refused by the device application and no detailed information of the incident is available occurs to a not existing index occurs to a not existing subindex Parameter is not accessible due to the current state of the device application Write access on a read-only parameter Written parameter value is outside its permitted value range Written parameter length is above its predefined length Written parameter length is below its predefined length Written command is not supported by the device application Written command is not available due to the current state of the device application Written single parameter collides with other actual parameter settings Parameter inconsistencies were found at the end of block parameter transfer, device plausibility check failed Read or write service is refused due to a temporarily unavailable application Page 14

Operating instructions Flow sensor SAxx00 SAxx10 SAxx30 SAxx40

Operating instructions Flow sensor SAxx00 SAxx10 SAxx30 SAxx40 Operating instructions Flow sensor SAxx00 SAxx10 SAxx30 SAxx40 UK 80260078 / 00 01 / 2017 Contents 1 Preliminary note...4 2 Safety instructions...4 3 Functions and features...5 4 Function...5 4.1 Operating

More information

Operating instructions Magnetic-inductive flow meter FMM FMM FMM

Operating instructions Magnetic-inductive flow meter FMM FMM FMM Operating instructions Magnetic-inductive flow meter FMM50-1001 FMM75-1001 FMM100-1001 Scan or Click the above QR Code or go to https://www.automationdirect.com/vid-fl-0003 for a short quick start video.

More information

Operating instructions Magnetic-inductive flow meter FMM FMM

Operating instructions Magnetic-inductive flow meter FMM FMM Operating instructions Magnetic-inductive flow meter FMM150-1001 FMM200-1001 Scan or Click the above QR Code or go to https:// www.automationdirect.com/ VID-FL-0004 for a configuration video with live

More information

Operating instructions Magnetic-inductive flow meter FMM FMM FMM

Operating instructions Magnetic-inductive flow meter FMM FMM FMM Operating instructions Magnetic-inductive flow meter FMM50-1002 FMM75-1002 FMM100-1002 Scan or Click the above QR Code or go to https://www.automationdirect.com/vid-fl-0003 for a short quick start video.

More information

Operating instructions Electronic level sensor LR / / 2012

Operating instructions Electronic level sensor LR / / 2012 Operating instructions Electronic level sensor LR3300 UK 706148 / 00 02 / 2012 Contents 1 Preliminary note...4 1.1 Symbols used...4 2 Safety instructions...4 3 Items supplied...5 4 Functions and features...6

More information

Operating instructions Electronic level sensor LK31xx

Operating instructions Electronic level sensor LK31xx Operating instructions Electronic level sensor LK31xx UK 80264298/ 00 06 / 2017 Contents 1 Preliminary note...4 1.1 ymbols used...4 2 afety instructions...4 3 Functions and features...5 3.1 Application

More information

Operating instructions. Electronic pressure sensor PY2068 ENGLISH

Operating instructions. Electronic pressure sensor PY2068 ENGLISH Operating instructions R Electronic pressure sensor PY068 704803/00 06/00 ENGLIH Contents afety instructions................................ page 0 Controls and indicating elements.....................

More information

Operating instructions Electronic level sensor LR / / 2016

Operating instructions Electronic level sensor LR / / 2016 Operating instructions Electronic level sensor LR3000 UK 80236081 / 00 02 / 2016 Contents 1 Preliminary note...4 1.1 Symbols used...4 2 Safety instructions...4 3 Items supplied...5 4 Functions and features...7

More information

Operating instructions Electronic level sensor LR2050

Operating instructions Electronic level sensor LR2050 Operating instructions lectronic level sensor LR2050 UK 80229610 / 01 06 / 2017 Contents 1 Preliminary note...5 1.1 Symbols used...5 2 Safety instructions...5 3 Items supplied...6 4 Getting started...6

More information

Operating instructions Electronic level sensor LR / / 2012

Operating instructions Electronic level sensor LR / / 2012 Operating instructions Electronic level sensor LR3000 UK 706147 / 00 01 / 2012 Contents 1 Preliminary note...4 1.1 Symbols used...4 2 Safety instructions...4 3 Items supplied...5 4 Functions and features...6

More information

Operating instructions. Combined pressure sensor PN /00 11/03

Operating instructions. Combined pressure sensor PN /00 11/03 Operating instructions R Combined pressure sensor PN 7080/00 /03 Contents afety instructions..................................... page 5 Controls and indicating elements.......................... page

More information

Operating instructions Electronic pressure sensor. PF205x /00 06/2011

Operating instructions Electronic pressure sensor. PF205x /00 06/2011 Operating instructions Electronic pressure sensor PF205x UK 706066/00 06/20 Contents Preliminary note...3. ymbols used...3 2 afety instructions...3 3 Functions and features...4 3. Applications...4 4 Function...4

More information

Operating instructions Electronic level sensor LR / / 2016

Operating instructions Electronic level sensor LR / / 2016 Operating instructions Electronic level sensor LR7000 UK 80236087 / 00 02 / 2016 Contents 1 Preliminary note...4 1.1 Symbols used...4 2 Safety instructions...4 3 Items supplied...5 4 Functions and features...7

More information

PI2794. Flush pressure sensor with display. 1 alphanumeric display 4-digit 2 status LEDs 3 programming button. Made in Germany

PI2794. Flush pressure sensor with display. 1 alphanumeric display 4-digit 2 status LEDs 3 programming button. Made in Germany 1 alphanumeric display 4-digit 2 status LEDs 3 programming button Made in Germany Application Application hygienic systems Media viscous media and liquids with suspended particles; liquids and gases Medium

More information

Operating instructions Measured signal converter for temperature sensors TP / / 2010

Operating instructions Measured signal converter for temperature sensors TP / / 2010 Operating instructions Measured signal converter for temperature sensors TP7 7068 / 00 0 / 00 Contents Preliminary note.... Symbols used... Safety instructions... Functions and features... Function...

More information

Operating instructions Electronic level sensor LK / / 2008

Operating instructions Electronic level sensor LK / / 2008 Operating instructions Electronic level sensor LK31 UK 704046 / 00 01 / 2008 Contents Safety instructions...2 Menu structure...3 Controls and indicating elements...4 Function and features...5 Functional

More information

Operating instructions Temperature transmitters. TA2xxx / / 2015

Operating instructions Temperature transmitters. TA2xxx / / 2015 Operating instructions Temperature transmitters TA2xxx UK 80026566 / 00 05 / 2015 Contents 1 Remark...2 1.1 Explanation of symbols...2 2 Safety instructions...3 3 Functions and features...3 Function...

More information

Operating instructions Electronic level sensor LR / / 2016

Operating instructions Electronic level sensor LR / / 2016 Operating instructions Electronic level sensor LR8010 UK 80005408 / 00 03 / 2016 Contents 1 Preliminary note...4 1.1 ymbols used...4 2 afety instructions...4 3 Items supplied...5 4 Functions and features...5

More information

Operating instructions Measured signal converter for temperature sensors. TP323x / / 2010

Operating instructions Measured signal converter for temperature sensors. TP323x / / 2010 Operating instructions Measured signal converter for temperature sensors TPx 70899 / 00 08 / 00 Contents Preliminary note.... Symbols used... Safety instructions... Functions and features... Function...

More information

Operating instructions Electronic level sensor LR / / 2016

Operating instructions Electronic level sensor LR / / 2016 Operating instructions Electronic level sensor LR8 UK 8237293 / 3 / 26 Contents Preliminary note...4. ymbols used...4 2 afety instructions...4 3 Items supplied...5 4 Functions and features...6 4. Operation

More information

Operating instructions Electronic level sensor LR / / 2012

Operating instructions Electronic level sensor LR / / 2012 Operating instructions Electronic level sensor LR8 765 / 2 / 22 Contents Preliminary note...4. ymbols used...4 2 afety instructions...4 3 Items supplied...5 4 Functions and features...6 4. Operation with

More information

NAT Applications. Features

NAT Applications. Features NAT 85 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of pressure and temperature. The industrial

More information

DPS Applications. Features

DPS Applications. Features DS 88 Display ressure Switch Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of and temperature. The DC 88 is the ideal combination

More information

IO-Link inductive sensors

IO-Link inductive sensors ZH DA ES FR DE IT EN IO-Link inductive sensors IBS04, ICS05, ICS08, ICB12, ICB18, ICB30 Instruction manual Manuale d istruzione Betriebsanleitung Manuel d instructions Manual de instrucciones Brugervejledning

More information

Info card. Ultrasonic sensors

Info card. Ultrasonic sensors i This info card serves as a supplement to the main position sensors catalogue and to the individual data sheets. For further information and contact addresses please visit our homepage at www.ifm.com.

More information

NAT Applications. Features

NAT Applications. Features NAT 85 Industrial Pressure Transmitter Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of pressure and temperature. The industrial

More information

PSD. Digital Pressure Sensor. LED Display with Switch & Analog Outputs

PSD. Digital Pressure Sensor. LED Display with Switch & Analog Outputs Digital ressure Sensor LED Display with Switch & Analog Outputs measuring monitoring analyzing SD Measuring Range: 0...30 to 0...7500 SI Temperature Range: -13...185 F Accuracy (at 77 F): ± 0.5 % FS Connection:

More information

Operating instructions Contrast sensor O5K / / 2016

Operating instructions Contrast sensor O5K / / 2016 Operating instructions Contrast sensor O5K500 707 / 00 / 06 Contents Preliminary note. Symbols used Functions and features Installation. Installation conditions Operating and display elements 5 5 Electrical

More information

BNI IOL E023 BNI IOL E023 BNI IOL E023 BNI IOL E023. User s Guide

BNI IOL E023 BNI IOL E023 BNI IOL E023 BNI IOL E023. User s Guide BNI IOL-717-002-E023 BNI IOL-725-002-E023 BNI IOL-730-002-E023 BNI IOL-740-002-E023 User s Guide Contents 1 Notes for the user 3 1.1. Structure of the guide 3 1.2. Typographical Conventions 3 Enumerations

More information

instabus EIB product documentation

instabus EIB product documentation Page: 1 of 39 Push button interface 4-gang Sensor Product name: Push button interface 4-gang Design: UP (flush-mounting type) Item no.: 2076-4T-01 ETS search path: Input / Binary Input, 4-gang / Push button

More information

Ultrasonic Sensor (HART)

Ultrasonic Sensor (HART) Characteristics 500 - LEVEL - DISTANCE - MODULAR - ECONOMIC - Input: - Ranges - Output: - Voltage supply: - Accuracy: - Process connection: - Electrical connection: - Temperature range: - Limit value contacts:

More information

Operating instructions Magnetic-inductive flow meter SM6050 SM7050 SM / / 2016

Operating instructions Magnetic-inductive flow meter SM6050 SM7050 SM / / 2016 Operating instructions Magnetic-inductive flow meter SM6050 SM7050 SM8050 UK 80237074 / 00 06 / 2016 Contents 1 Preliminary note...3 2 Safety instructions...3 3 unctions and features...4 4 unction...4

More information

Operating instructions PMD 3D sensor. O3D2xx /02 04 / 2015

Operating instructions PMD 3D sensor. O3D2xx /02 04 / 2015 Operating instructions PMD 3D sensor O3D2xx 704538/02 04 / 2015 Contents 1 Preliminary note................................................. 4 1.1 Warning signs used..........................................

More information

The AT4222 module is equipped with four inputs for PT100/PT1000 resistance temperature measurement.

The AT4222 module is equipped with four inputs for PT100/PT1000 resistance temperature measurement. 22.3 AT4222 22.3.1 General information The AT4222 module is equipped with four inputs for PT100/PT1000 resistance temperature measurement. 4 inputs for resistance temperature measurement For PT100 and

More information

A TEMPOSONICS R

A TEMPOSONICS R m Sensor Techlogie TEMPOSONICS R 9 A R Series CANopen DS6 V. Operating Manual Configuration and CAN-Bus Coupling TEMPOSONICS R-Serie CANopen DS6 Index CAN Bus Interface System description Configuration

More information

Interface Description

Interface Description Interface Description True-Color-Sensor with IO-Link Ordering code: Part number: BFS000M BFS 33M-GSI-F01-S75 Document number: 920685 E 01.119905 Edition E15 replaces Edition C15 Subject to changes Page

More information

Interface Description

Interface Description Interface Description True-Color-Sensor with IO-Link Ordering code: Part number: BFS000M BFS 33M-GSI-F01-S75 Document number: 920685 E 0726 03.123343 Edition K16 replaces Edition F16 Subject to changes

More information

InsuLogix T MODBUS Protocol Manual

InsuLogix T MODBUS Protocol Manual InsuLogix T MODBUS Protocol Manual Weidmann Technologies Deutschland GmbH Washingtonstraße 16/16a D-01139 Dresden, Germany Telefon: +49 (0)351 8435990 Version 1.1 InsuLogix T MODBUS Protocol Manual 1 Contents

More information

GEMÜ 1242 Electrical position indicator

GEMÜ 1242 Electrical position indicator Electrical position indicator Features Fieldbus connection AS-Interface and DeviceNet (optional) Communication and programming interface IO-Link Adjustable switch point tolerances Speed -AP function for

More information

Flow sensor SFAH. Platzhalter. Description [ ]

Flow sensor SFAH. Platzhalter. Description [ ] Flow sensor en Description Platzhalter 8075046 2017-09 [8075048] Translation of the original instructions Installation and commissioning must be carried out only by properly qualified personnel in accordance

More information

10 Error Code List. Motion Control SW. NTI AG / LinMot User Manual Motion Control SW/ Page 87/94

10 Error Code List. Motion Control SW. NTI AG / LinMot User Manual Motion Control SW/ Page 87/94 Motion Control SW L i n M o t 10 List Code Description Actions to take 0000h No Error No error is pending. 0001h X4 Logic Supply Too Low The logic supply voltage has been too low. The minimal logic supply

More information

Manual. Application Inverter MOVIDRIVE modular/system with CiA402 Device Profile Parameter Description * _0718*

Manual. Application Inverter MOVIDRIVE modular/system with CiA402 Device Profile Parameter Description * _0718* Drive Technology \ Drive Automation \ System Integration \ Services *25835130_0718* Manual Application Inverter MOVIDRIVE modular/system with CiA402 Device Profile Parameter Description Edition 07/2018

More information

Operating instructions Switching amplifier for fibre optics. OBF5xx / / 2009

Operating instructions Switching amplifier for fibre optics. OBF5xx / / 2009 Operating instructions Switching amplifier for fibre optics OBF5xx 704513 / 00 04 / 009 Contents 1 Preliminary note...3 1.1 Symbols used...3 Functions and features...3.1 Applications...3 3 Installation...3

More information

Technical Bulletin, Communicating with Honeywell TM ST3000/STT3000 Smart Transmitters

Technical Bulletin, Communicating with Honeywell TM ST3000/STT3000 Smart Transmitters Last Updated: 10-March-2009 TB-960704B Technical Bulletin, Communicating with Honeywell TM ST3000/STT3000 Smart Transmitters OMNI FLOW COMPUTERS, INC. 12620 West Airport Boulevard, Suite 100 Sugar Land,

More information

Distance sensors. System description. Distance measurement using triangulation

Distance sensors. System description. Distance measurement using triangulation Distance sensors System description Distance measurement using triangulation The measurement principle of optical triangulation is suitable for the precise determination of distances at close range. With

More information

The DO8332 module is equipped with eight outputs for 1-wire connections. The rated output current is 2 A.

The DO8332 module is equipped with eight outputs for 1-wire connections. The rated output current is 2 A. 1.1 DO8332 1.1.1 General information The DO8332 module is equipped with eight outputs for 1-wire connections. The rated output current is 2 A. The output supply is fed directly to the module. An additional

More information

Modbus Integration Integration for Modbus Functionality for VT8300 Series

Modbus Integration Integration for Modbus Functionality for VT8300 Series Modbus Integration Integration for Modbus Functionality for VT8300 Series Building Management System *For data visualization and analysis Modbus Controller VT8000 Series room controllers 2 TABLE OF CONTENTS

More information

SIMATIC ET 200SP. Digital input module DI 8xNAMUR (6ES7131-6TF00-0CA0) Manual. Answers for industry.

SIMATIC ET 200SP. Digital input module DI 8xNAMUR (6ES7131-6TF00-0CA0) Manual. Answers for industry. SIMATIC ET 200SP Digital input module DI 8xNAMUR (6ES7131-6TF00-0CA0) Manual Edition 02/2014 Answers for industry. DI 8xNAMUR HF digital input module (6ES7131-6TF00-0CA0) SIMATIC ET 200SP DI 8xNAMUR HF

More information

Configuration of CPE 310-S and CPE 311-S transmitters by keypad

Configuration of CPE 310-S and CPE 311-S transmitters by keypad Configuration of CPE 310-S and CPE 311-S transmitters by keypad Table of contents 1. Introduction...5 1.1. Description of the transmitter...5 1.2. Description of the keys...5 1.3. Protection tips of the

More information

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data Technical documentation Table of content Page 2: Page 3: Page 4: Page 5: Page 6: Page 7: Page 8: Characteristics - applications - technical data Technical data - input quantity - output quantity Electrical

More information

Rev ABB i-bus KNX 6151/11 U-500. Power and productivity for a better world TM

Rev ABB i-bus KNX 6151/11 U-500. Power and productivity for a better world TM 1 73-1-7831 Rev. 01 3.2012 6151/11 U-500 Power and productivity for a better world TM Page: 1 of 31 Switching actuator 1gang with binary Inputs, FM Actuator Article-no.: 6151/11 U-500 ETS search path:

More information

Optical laser distance sensors. Dimensioned drawing

Optical laser distance sensors. Dimensioned drawing Dimensioned drawing en 02-2012/11 50118552 50 100mm 18-30 V DC We reserve the right to make changes DS_ODSL9L100_en_50118552.fm High resolution 0.01mm Reflection-independent distance information Highly

More information

Copyright 2014 YASKAWA ELECTRIC CORPORATION All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or

Copyright 2014 YASKAWA ELECTRIC CORPORATION All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or Copyright 2014 YASKAWA ELECTRIC CORPORATION All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, mechanical, electronic,

More information

Width (W): 44 mm. bus connecting and branching terminal External supply --- Inputs: Number: up to 2 (depending on parameterization: channel 1 to 2)

Width (W): 44 mm. bus connecting and branching terminal External supply --- Inputs: Number: up to 2 (depending on parameterization: channel 1 to 2) Product name: Design: 2-channel push button interface UP (flush-mounting type) Item no.: 1118 00 ETS search path: Gira Giersiepen / input / binary input, 2fold / Universal push putton interface 2fold Functional

More information

LASER. Analog Laser Displacement Transducer. LAM Series. Key-Features: Content:

LASER. Analog Laser Displacement Transducer. LAM Series. Key-Features: Content: LASER Analog Laser Displacement Transducer LAM Series Key-Features: Content: Overview, Measuring Principle...2 Installation Instructions...3 Technical Data...4 Technical Drawings.7 Electrical Connection...9

More information

BACnet Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement BACnet Protocol Implementation Conformance Statement Date: October 06, 2009 Vendor Name: Schneider Electric Product Name: Low Voltage AC Motor Drive Product Model Number: Altivar 61 Application Software

More information

Optical laser distance sensors. Dimensioned drawing

Optical laser distance sensors. Dimensioned drawing ODSLR 96B Optical laser distance sensors Dimensioned drawing en 05-2012/11 50110336 60 2000mm 18-30 V DC We reserve the right to make changes DS_ODSLR96BMCV62000_en_50110336.fm Reflection-independent distance

More information

Sensor BACnet PICS. Contents. 1. Operating elements for addressing and parametrization 2 2. Protocol Implementation Conformance Statement - PICS 3

Sensor BACnet PICS. Contents. 1. Operating elements for addressing and parametrization 2 2. Protocol Implementation Conformance Statement - PICS 3 Sensor Sensor BACnet PICS 22DTH-..6.. Duct sensor humidity / temperature 22UTH-..60X Outdoor sensor humidity / temperature 22DTM-..6 Duct sensor CO2 / humidity / temperature Contents 1. Operating elements

More information

X20(c)AI General information. 2 Coated modules. 3 Order data. X20(c)AI4622

X20(c)AI General information. 2 Coated modules. 3 Order data. X20(c)AI4622 X20(c)AI4622 1 General information The module is equipped with 4 inputs with 13-bit (including sign) digital converter resolution. It is possible to select between the current and voltage signal using

More information

The keypad is used to set the flowmeter. The function of the keys are as follows: This key selects the figures to be changed.

The keypad is used to set the flowmeter. The function of the keys are as follows: This key selects the figures to be changed. 7. 7.1 Keypad and display layout Keypad The keypad is used to set the flowmeter. The function of the keys are as follows: TOP UP KEY FORWARD KEY BACKWARD KEY CHANGE KEY SELECT KEY LOCK/UNLOCK KEY This

More information

Ultrasonic sensors. Reliable on almost all surfaces. UT 20 from Page 548. UT 12 from Page 564. UT/UM 18 from Page 568

Ultrasonic sensors. Reliable on almost all surfaces. UT 20 from Page 548. UT 12 from Page 564. UT/UM 18 from Page 568 Ultrasonic sensors Reliable on almost all surfaces UT 0 from Page 58 UT from Page 56 UT/UM 8 from Page 568 UT 0-S miniature ultrasonic sensors with soundpipe Reliable detection through the smallest of

More information

INSTRUCTION MANUAL FOR ULTRASONIC/MICROWAVE SENSORS

INSTRUCTION MANUAL FOR ULTRASONIC/MICROWAVE SENSORS INSTRUCTION MANUAL FOR ULTRASONIC/MICROWAVE SENSORS 1)Install PROBE_GatewayPC Software on PC.Remove previous installation. In Windows Control Panel go to the Programs and Features, select Probe_GatewayPC_Net

More information

Photoelectric Sensors. Manual. True-Color-Sensor with IO-Link. Document number: E Edition C15 Subject to changes.

Photoelectric Sensors. Manual. True-Color-Sensor with IO-Link. Document number: E Edition C15 Subject to changes. Manual True-Color-Sensor with IO-Link Ordering code: Part number: BFS000M BFS 33M-GSI-F01-S75 Document number: 920685 E Edition C15 Subject to changes Page 1 / 20 Contents 1. Introduction... 3 2. Safety

More information

Laser light scanner with background suppression. Dimensioned drawing

Laser light scanner with background suppression. Dimensioned drawing Dimensioned drawing We reserve the right to make changes DS_HT10_2M_en_0130293.fm en 01-201/09 0130293 18-30 V DC 0 2000mm The laser light scanner, based on the principle of light propagation time measurement,

More information

MK110-8D.4R. Digital I/O-Module 12 channel 8 DI, 4 DO. User guide

MK110-8D.4R. Digital I/O-Module 12 channel 8 DI, 4 DO. User guide MK110-8D.4R Digital I/O-Module 12 channel 8 DI, 4 DO User guide MK110-8D4R_2016.12_0219_EN All rights reserved Subject to technical changes and misprints akytec GmbH Vahrenwalder Str. 269 A 30179 Hannover

More information

Technical data: Instabus EIB supply Voltage: YY 6 x 0.6 mm; red: bus (+) / black: bus (-)

Technical data: Instabus EIB supply Voltage: YY 6 x 0.6 mm; red: bus (+) / black: bus (-) Product designation: switching actuator 2fold 6A FM Design: FM (flush-mounted type) Article no.: 1057 00 ETS search path: Gira Giersiepen / Output / Binary output, 2fold / switching actuator 2fold 6A FM

More information

User Manual. Color Registration Mark Sensor with IO-Link Interface 45CRM-4LHT*-D4

User Manual. Color Registration Mark Sensor with IO-Link Interface 45CRM-4LHT*-D4 User Manual Color Registration Mark Sensor with IO-Link Interface 45CRM-4LHT*-D4 Important User Information Because of the variety of uses for the products described in this publication, those responsible

More information

PARAMETER LIST MICROFUSION

PARAMETER LIST MICROFUSION MICROFUSION PARAMETER LIST MicroFUSION controllers contain nonvolatile EEPROMs, and writing too frequently to an individual parameter may wear out the EEPROM and cause the controller to fail. Control Concepts

More information

VEGAFLEX 80 two-wire 4 20 ma/hart

VEGAFLEX 80 two-wire 4 20 ma/hart VEGAFLEX 80 two-wire 4 20 ma/hart.3.0 2/206 Function extensions New functions and modifications: Bulk solids applications Standard deactivation of the automatic false signal suppression Standard deactivation

More information

BAC-IO9 BACnet MS/TP Input / Output Modules, Wall Mounted

BAC-IO9 BACnet MS/TP Input / Output Modules, Wall Mounted Product sheet MOD Type BAC-IO9 BAC-IO9 BACnet MS/TP Input / Output Modules, Wall Mounted BAC-IO9 and BAC-IO9-AI have been designed to be a compact wall mounted BACnet MS/TP input and output modules. The

More information

5096 FIRMWARE ENHANCEMENTS

5096 FIRMWARE ENHANCEMENTS Document Number A100745 Version No.: 4.4.1 Effective Date: January 30, 2006 Initial Release: September 19, 2005 1. Fixed display of logged memory date and time broken in version 4.3. 2. Allow time samples

More information

PalmGauss SC PGSC-5G. Instruction Manual

PalmGauss SC PGSC-5G. Instruction Manual PalmGauss SC PGSC-5G Instruction Manual PalmGauss SC PGSC 5G Instruction Manual Thank you very much for purchasing our products. Please, read this instruction manual in order to use our product in safety

More information

Microprocessor-based Temperature Controller

Microprocessor-based Temperature Controller R 1100 The Temperature Controller Heat-only Controller Heating-off-Cooling Controller DIN-Format: 96 x 96 mm Installation depth: 67 mm Microprocessor-based Temperature Controller Description And Operating

More information

Revision 1. March 21, ADC Operation Manual N 11 th St San Jose CA

Revision 1. March 21, ADC Operation Manual N 11 th St San Jose CA Revision 1 March 21, 2017 ADC Operation Manual www.mountztorque.com - 1080 N 11 th St San Jose CA 95112 408.292.2214 1 Index 1. Installation 3 1.1 Required PC specification 3 1.2 Software 3 2. Operation

More information

CS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL

CS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL CS-200 PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL CS-200 Operation and Service Manual Page 2 Manufactured by: LINCAST INTERNATIONAL PTY. LTD. 2/3 Sir Laurence Drive

More information

BACnet- MS/TP COMMUNICATION V

BACnet- MS/TP COMMUNICATION V - MS/TP COMMUNICATION V1.00.08.17 11.1 Introduction The VFD can be controlled and monitored through the BACnet MS/TP protocol over an RS-485 connection. The VFD operates as an MS/TP master device, which

More information

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2018

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2018 Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D104 706114 / 00 02 / 2018 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warning signs used...3 2 Safety

More information

Brushed DC Motor Control. Module with CAN (MDL-BDC24)

Brushed DC Motor Control. Module with CAN (MDL-BDC24) Stellaris Brushed DC Motor Control Module with CAN (MDL-BDC24) Ordering Information Product No. MDL-BDC24 RDK-BDC24 Description Stellaris Brushed DC Motor Control Module with CAN (MDL-BDC24) for Single-Unit

More information

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35 www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up

More information

F2A3X Frequency to Analog Converter Module

F2A3X Frequency to Analog Converter Module the professional s choice F2A3X Frequency to Analog Converter Module Instruction Manual MONARCH INSTRUMENT 15 Columbia Drive Amherst, NH 03031 USA Phone: (603) 883-3390 Fax: (603) 886-3300 E-mail: support@monarchinstrument.com

More information

I-7088, I-7088D, M-7088 and M-7088D User Manual

I-7088, I-7088D, M-7088 and M-7088D User Manual I-7088, I-7088D, M-7088 and M-7088D User Manual I-7000 New Features 1. Internal Self Tuner 2. Multiple Baud Rates 3. Multiple Data Formats 4. Internal Dual WatchDog 5. True Distributed Control 6. High

More information

maxon document number:

maxon document number: maxon document number: 791272-04 1 Table of contents... 2 2 Table of figures... 3 3 Introduction... 4 4 How to use this guide... 4 5 Safety Instructions... 5 6 Performance Data... 6 6.1 Motor data... 6

More information

theben Fan Coil Actuator FCA 1 Fan Coil Actuator FCA 1 FCA Version: Jan-08 (Subject to change) Page 1 of 77

theben Fan Coil Actuator FCA 1 Fan Coil Actuator FCA 1 FCA Version: Jan-08 (Subject to change) Page 1 of 77 Fan Coil Actuator FCA 1 FCA 1 492 0 200 Version: Jan-08 (Subject to change) Page 1 of 77 Contents 1 Functional characteristics...4 1.1 Operation and display...5 1.2 Advantages of the FCA 1...5 1.2.1 Special

More information

Enhanced PID for Air Compressors F7 Drive Software Technical Manual

Enhanced PID for Air Compressors F7 Drive Software Technical Manual Software Number: VSF11020X, Drive Models: CIMR-F7UXXXXXX-096 Document Number: TM.F7SW.096, Date: 08/01/05, Rev: 05-08 Enhanced PID for Air Compressors F7 Drive Software Technical Manual This document is

More information

Compact Multiprotocol I/O Module for Ethernet 8 Universal Digital Channels, Configurable as PNP Inputs or 0.5A Outputs TBEN-S1-8DXP

Compact Multiprotocol I/O Module for Ethernet 8 Universal Digital Channels, Configurable as PNP Inputs or 0.5A Outputs TBEN-S1-8DXP PROFINET device, EtherNet/IP device or Modbus TCP slave Integrated Ethernet switch Supports 10 Mbps/100 Mbps 2x M8, 4-pin, Ethernet fieldbus connection Glass fiber reinforced housing Shock and vibration

More information

Parameter Value Unit Notes

Parameter Value Unit Notes Features Single axis measurement from ±5 to ±60 High resolution and accuracy. Low temperature drift, with optional temperature compensation to further improve temperature performance. RS232 and RS485 output

More information

Device manual Multifunction display and evaluation system FX 360. Mode/Enter

Device manual Multifunction display and evaluation system FX 360. Mode/Enter Device manual Multifunction display and evaluation system FX 360 7390275 / 08 07 / 2009 Mode/Enter Set Safety instructions This manual is part of the unit. It contains texts and diagrams for the correct

More information

PROPRIETARY CAN COMMUNICATION DOCUMENT. Proprietary CAN Communication for the PCS Automatic Transmission Controller

PROPRIETARY CAN COMMUNICATION DOCUMENT. Proprietary CAN Communication for the PCS Automatic Transmission Controller Proprietary CAN Communication for the PCS Automatic Transmission Controller 1. Overview The PCS TCU transmits and receives information over a CAN 2.0b Bus. Before implementing CAN communication using the

More information

Interface Description A2000. Multifunctional Power Meter Communications Protocol per DIN Draft /2.15

Interface Description A2000. Multifunctional Power Meter Communications Protocol per DIN Draft /2.15 Interface Description A2000 Multifunctional Power Meter Communications Protocol per DIN Draft 19244 3-349-125-03 14/2.15 1 Overview of Telegrams (Commands) to the A2000 per DIN Draft 19244...4 2 Telegram

More information

Proximity Sensor Terminology

Proximity Sensor Terminology The following descriptions refer to the European standard EN 60947-5-2. of 2007. The specifications given here are intended to be minimum performance values described by the standard. Alignment must not

More information

Jaguar Motor Controller (Stellaris Brushed DC Motor Control Module with CAN)

Jaguar Motor Controller (Stellaris Brushed DC Motor Control Module with CAN) Jaguar Motor Controller (Stellaris Brushed DC Motor Control Module with CAN) 217-3367 Ordering Information Product Number Description 217-3367 Stellaris Brushed DC Motor Control Module with CAN (217-3367)

More information

HPVFP High Performance Full Function Vector Frequency Inverter

HPVFP High Performance Full Function Vector Frequency Inverter Advanced User Manual HPVFP High Performance Full Function Vector Frequency Inverter HP VER 1.00 1. HPVFP Parameter Set Overview...3 1.1. About this section...3 1.2. Parameter Structure Overview...3 1.3.

More information

ASCII Programmer s Guide

ASCII Programmer s Guide ASCII Programmer s Guide PN/ 16-01196 Revision 01 April 2015 TABLE OF CONTENTS About This Manual... 3 1: Introduction... 6 1.1: The Copley ASCII Interface... 7 1.2: Communication Protocol... 7 2: Command

More information

User manual. KNX MultiController DALI. Article number: 5410x / 5411x. function Technology AS

User manual. KNX MultiController DALI. Article number: 5410x / 5411x. function Technology AS User manual KNX MultiController DALI Article number: 5410x / 5411x Picture: KNX MultiController DALI with Reed panel and sensor function Technology AS Table of contents 1 KNX MULTICONTROLLER... 3 2 INTRODUCTION...

More information

Vibration 10 Times in X,Y,Z IEC In Case of Continuous Vibration

Vibration 10 Times in X,Y,Z IEC In Case of Continuous Vibration FEATURES LED Display to Monitor Running Conditions PhotoCoupler Insulated Snapin Installation Terminal BlockType 4bit (/6,84) or 6bit (/65,55) Resolution 4 or 8 Channels Voltage or DESCRIPTION PLCAIOCMAD

More information

FAST SAMPLING CONVERTER

FAST SAMPLING CONVERTER FAST SAMPLING CONVERTER ML4-F1 HIGH SAMPLING RATE CONVERTER (UP TO 400 SAMPLES/SECOND) Warranty conditions are available on this website: www.isomag.eu only in English version INDEX TECHNICAL DATA... 3

More information

Temperature Monitoring and Fan Control with Platform Manager 2

Temperature Monitoring and Fan Control with Platform Manager 2 August 2013 Introduction Technical Note TN1278 The Platform Manager 2 is a fast-reacting, programmable logic based hardware management controller. Platform Manager 2 is an integrated solution combining

More information

PROXIMITY SENSOR TERMINOLOGY

PROXIMITY SENSOR TERMINOLOGY Never use this desk reference for installation or operation of equipment. Refer to manual for installation and operation instructions. The following descriptions refer to the European standard EN 60947-5-2.

More information

Copley ASCII Interface Programmer s Guide

Copley ASCII Interface Programmer s Guide Copley ASCII Interface Programmer s Guide PN/95-00404-000 Revision 4 June 2008 Copley ASCII Interface Programmer s Guide TABLE OF CONTENTS About This Manual... 5 Overview and Scope... 5 Related Documentation...

More information

Installation Instructions RF-identification system Read/write head ANT513

Installation Instructions RF-identification system Read/write head ANT513 Installation Instructions RF-identification system Read/write head ANT513 80262946 / 00 04 / 2017 Contents 1 Preliminary note...4 1.1 Symbols used...4 2 Safety instructions...4 2.1 General...4 2.2 Radio

More information