2016 Approved Material Listing

Size: px
Start display at page:

Download "2016 Approved Material Listing"

Transcription

1 Regional Municipality of Niagara 2016 Approved Material Listing Rigid PVC Traffic Duct HDPE Traffic Duct 50 mm (2 ) 100 mm (4 ) Sceptre or approved Sceptre or approved - Electric - Electric 50 mm (2 ) Lamson SDR 13.5 Electric 100 mm (4 ) Lamson SDR 13.5 Electric Conduit Bell Ends Flared Junction Boxes (Underground Enclosure) Pole Foundation Anchor Assemblies Pedestrian Button Pole Traffic Signal and Street Light Poles 50 mm (2 ) Sceptre EB-35 Electric 100 mm (4 ) Sceptre EB-35 Electric Polymer (13 x 24 x 18 ) c/w lid, penta bolt Type 1 1cm x 19cm x 19cm (¾ x 7 ½ x 7 ½ ) 2cm x 23cm x 23cm (1 x 9 x 9 ) 3cm x 28cm x 28cm (1 ¼ x 11 x 11 ) 3cm x 32cm x 32cm (1 ¼ x12 ½ x12 ½ ) 3cm x42cm x 42cm (1 ¼ x16 ½ x16 ½ ) Type 1 PB 1.52 m (5 ) 3.60 m (12 ) 9.14 m (30 ) 10.5 m (35 ) (Direct Bury) 7.0 m (24 ) Hubble Power Systems Spun Aluminum B A C A DGR-2S-190 DGR-2S-323 DGR-2S-395 DGR-2S-449 DGR-2S-592 TP5-550A-AB190 SS12B SS13B EA-SS35B EA-TB15B EA-C51980 Electric A Page 1 of 5 Rev. date:

2 9.14 m (30 ) Arm C (TAB) m (35 ) Arm C52387(TAB) Type (Direct Bury) 12.0 m (39.5 ) Decorative Pole Pole 12.2m (40 ) C51983 Polefab Inc StressCrete 206A StressCrete Group StressCrete NR-40BPR StressCrete Group 1.22 m (4.0 ) Aluminous TR4-SMA 1.82 m (6.0 ) Aluminous TR6-SMA 2.44 m (8.0 ) Aluminous TR8-SMA 3.05 m (10.0 ) Aluminous TR10-SMA 3.66 m (12.0 ) Aluminous TR12-SMA Traffic Signal Mast Arms 4.57 m (15.0 ) Aluminous TR15-SMA 5.48 m (18.0 ) Aluminous TR18-SMA 6.09 m (20.0 ) Aluminous TR20-SMA 6.70 m (22.0 ) Aluminous TR22-SMA 7.62 m (25.0 ) Aluminous TR25-SMA Pole Plates 4TR56 to 6TR81 Pole Basket Hanger Arms Pole Banner Arms Ground Rod Pedestrian Push Button Assembly Accessible Pedestrian Push Button Traffic Signal Heads Flower Pot Support Arms Round Tapered Banner Arm 25 ¾ X 10 copper clad pointed - #BNA25-BL Thomas & Betts 7510 Westburn or Black Low Profile Bulldog PBBDLM-B Tacel Ltd. Audible and vibrating push button Polara Navigator N25ANC-B Tacel Ltd. Housing - LED Signal Lens Trastar - Pedestrian Signal Heads 1 Section LED Bi Modal or two section with countdown Swarco or Trastar - Page 2 of 5

3 Traffic Signal Head Bracket Pedestrian Head Extension Bracket Versa-Brac Bracket Assembly 40 cm (18 ) Extension Bracket VSB-338 VSB-346 VSB Traffic Signal Cabinet Base Mounted Traffic Signal Controller NEMA TS2 Malfunction Management Unit NR Spec MXX, UPS Pole Mounted NR Spec G ASC/3-LX Cobalt MMU MMU-16LEip Bus Interface Unit BIU 32860G1 Load Switches P1 Flasher Units P1 Power Supply G1 Power Supply Control Cabinet Stainless See NRS 2130 NRS 2440 B & M MTOD-001 MTOD-003 S B & M Manufacturing Loop Detector 4 Channel EDI Oracle 4e Loop Detector Cable 14 AWG - RWU90 Traffic Signal Cable Loop Lead Cable Push Button Cable Video Detection Cable Communication Cable Overhead Detection 25 Conductor 11 Conductor 7 Conductor 4 Conductor 16 AWG (black/white) Grey Jacket 16 AWG (black/red) Black Jacket 4 Conductor Siamese cable Fiber Optic Cable Video Detector Video Detector Radar Detector Traffic Cable Regional Niagara Beldon Type - Beldon Type - Traffic Cable 16-3/RG 59/U GCC Optical Cable Iteris Wavetronix Niagara Region I59PVCC-00 SM-MIA-WB Encore RZ-4 AWDR Matrix GGI Fortran School Zone Flasher (Solar and Hardwire) Programmable Flasher RTC AP22 Page 3 of 5

4 Street Lighting Luminaire Philips Roadview Philips RoadFocus G.E. 160W144LED4K 160W48LED4K Evolve ERS30LXBX540 1GRAYL Electric Graybar Electric Graybar Electric Street Light Arms (Elliptical) Street Light Arms for Wood Poles Uninterruptable Power Supply (UPS) 1.82 m (6.0 ) Aluminous RE6M 2.44 m (8.0 ) Aluminous RE8M 2.44 m (8.0 ) MTO Aluminous RE-8H 3.05 m (10.0 ) Aluminous RE10M Decorative Arm 1.82 m (6.0 ) (not elliptical) StressCrete Group Aluminum 2.44 m (8.0 ) Aluminous ALP-WE8M 3.05 m (10.0 ) Aluminous ALP-WE10M 3.66 m (12.0 ) Aluminous ALP-WE12M or or or or 206A StressCrete Group or or or Inverter/Controller Blue Earth UPStealth ITS Batteries Nickel Zinc, sealed UPStealth NEMA ITS Vehicle Pre-Emption Vehicle Unit Emtrac Vehicle Pre-Emption Intersection Unit Emtrac ST-9282-E- VEHKIT-NIA ST-9281-INTKIT- NIA Vehicle Pre-Emption Interrogator Emtrac ST-9184-K Vehicle Pre-Emption GPS/UHF Antenna Emtrac ST-9065-L25 Wireless Communication Radios Ethernet Managed Switch 5.8GHZ Wideband Radio Managed Switch with power supply DM-WB MS-5 Managed Switch Comnet CNGE Traffic Camera Managed Switch Cisco IE 3000 IT Yuda PTZ MPEG4 encoder PTZ Mpeg4 Design Electronics PTZ-SDIS-36- ENC-PSM PTZ-16 x 9 Design Electronics Page 4 of 5

5 Single Solar Flasher Kit-1 Solar Flasher Dual Solar Flasher Kit-2 School Zone Crossing School Zone GPS Time Sync Device GPS Time Clock SimSYNC Solar Powered Radio Repeater Solar Powered Charge Unit Solar Repeater Serial Radio Serial Data Radio Datamover SS Spread Spectrum Transceiver Fiber Optic Patch Panel Sidewalk Tactile Warning Plates Status indicator System Datamover IO Outdoor rated patch Panel Gator Patch Gator Patch- Length Cast Iron Plates - - Neenah Foundry East Jordan Foundry Page 5 of 5

Office of Traffic Operations Signal Design Reference Packet

Office of Traffic Operations Signal Design Reference Packet Office of Traffic Operations Signal Design Reference Packet Rev-3 07/17/2015 Contents The purpose of this packet is to provide guidance on designing and reviewing traffic signal plans. The format, legends,

More information

2.0 TRAFFIC SIGNAL DESIGN GUIDELINES

2.0 TRAFFIC SIGNAL DESIGN GUIDELINES SECTION 2 2.0 TRAFFIC SIGNAL DESIGN GUIDELINES 2.1 SIGNAL DESIGN ELEMENTS Any traffic signal proposed for installation on City streets shall meet the minimum criteria as outlined in the Manual on Uniform

More information

Traffic Signals Materials and Installation Specifications. Highway 104: Exit 23 Westville Road at MacGregor Avenue. Pictou County, Nova Scotia

Traffic Signals Materials and Installation Specifications. Highway 104: Exit 23 Westville Road at MacGregor Avenue. Pictou County, Nova Scotia Traffic Signals Materials and Installation Specifications Highway 104: Exit 23 Westville Road at MacGregor Avenue Pictou County, Nova Scotia Traffic Signals Materials and Installation Specifications Table

More information

MDOTProjectwise\Documents\Reference Documents\Traffic Reference\Statewide Special Details\Develop

MDOTProjectwise\Documents\Reference Documents\Traffic Reference\Statewide Special Details\Develop 500 460 MDOTProjectwise\Documents\Reference Documents\Traffic Reference\Statewide Special Details\Develop Check if Applicable TRAFFIC SIGNAL SPECIAL DETAILS INDEX/CHECKLIST *One completed checklist required

More information

INTRO TRAFFIC 101. What is the purpose of a traffic signal? What are the parts that make it work? How do we time a traffic signal?

INTRO TRAFFIC 101. What is the purpose of a traffic signal? What are the parts that make it work? How do we time a traffic signal? INTRO TRAFFIC 101 What is the purpose of a traffic signal? What are the parts that make it work? How do we time a traffic signal? How do we maintain a traffic signal? What is the purpose of a traffic signal?

More information

REVISION INFORMATION SHEET ONTARIO PROVINCIAL STANDARDS FOR ROADS AND PUBLIC WORKS

REVISION INFORMATION SHEET ONTARIO PROVINCIAL STANDARDS FOR ROADS AND PUBLIC WORKS Ontario Provincial Standards 301 St. Paul St., 2 nd Floor North St. Catharines, ON L2R 7R4 REVISION INFORMATION SHEET ONTARIO PROVINCIAL STANDARDS FOR ROADS AND PUBLIC WORKS VOLUME 4 MUNICIPAL AND PROVINCIAL

More information

Cisco Aironet 2.4-GHz/5-GHz 8-dBi Directional Antenna (AIR-ANT2588P3M-N)

Cisco Aironet 2.4-GHz/5-GHz 8-dBi Directional Antenna (AIR-ANT2588P3M-N) Cisco Aironet.4-GHz/5-GHz 8-dBi Directional Antenna (AIR-ANT588P3M-N) This document outlines the specifications for the Cisco Aironet AIR-ANT588P3M-N.4/5-GHz 8-dBi 3-Port Directional Antenna with N-connectors

More information

RECTANGULAR RAPID FLASHING BEACON WITH LARGE LED ARRAYS TAPCO RRFB-XL : Solar Powered; Extra Large LED Arrays, Wirelessly Synchronized

RECTANGULAR RAPID FLASHING BEACON WITH LARGE LED ARRAYS TAPCO RRFB-XL : Solar Powered; Extra Large LED Arrays, Wirelessly Synchronized RECTANGULAR RAPID FLASHING BEACON WITH LARGE LED ARRAYS TAPCO RRFB-XL : Solar Powered; Extra Large LED Arrays, Wirelessly Synchronized 1.0 Description The Manufacturer shall provide a Rectangular Rapid

More information

SIGN MOUNTED BEACON SIG-027-A SINGLE SIGN MOUNTED FLASHING BEACON INSTALLED ON ONE WOOD POST DETAIL "A-1"

SIGN MOUNTED BEACON SIG-027-A SINGLE SIGN MOUNTED FLASHING BEACON INSTALLED ON ONE WOOD POST DETAIL A-1 1 1/2" x 60" Galvanized (thread both ends) Top Bolt See Detail "A-1" and Slotted Channel Parallel Conduit Clamp Warning Sign 3 Equal Bolt Spacings (3 places at 12" min. spacing) (1) 3/8"x 7" min. (4"x

More information

MAST ARMS & POLES. Ornamental Pole Top & Bases

MAST ARMS & POLES. Ornamental Pole Top & Bases Ornamental Pole Top & Bases Pelco s decorative pole top and bases make the traffic signal aesthetically pleasing to the eye. In addition to the standar 4-piece, Pelco also manufactures the bases with an

More information

M-0418 REV:0

M-0418 REV:0 1 of 5 This specification sets forth the minimum requirements for purchase and installation of an aboveground Radar Detection Device (RDD) system for a real-time, stop bar vehicle-detection system that

More information

icite Product Line DA-DATA AGGREGATOR DA-100B

icite Product Line DA-DATA AGGREGATOR DA-100B icite Product Line DA-DATA AGGREGATOR DA-100B DA-DATA AGGREGATOR DA-100B BASIC CABINET MONITORING The first system to provide cost effective remote traffic cabinet status and intersection data without

More information

INVITATION TO BID. * EA Mounted) 24 Detector Card (NEMA TS-2) * EA 25 Concrete Curb Ramp *848 5 EA

INVITATION TO BID. * EA Mounted) 24 Detector Card (NEMA TS-2) * EA 25 Concrete Curb Ramp *848 5 EA INVITATION TO BID TOWN OF CARY Cary, North Carolina Sealed bids must be submitted no later than 1:30 p.m. on October 1, 2018 to the Town of Cary at the office of the Transportation and Facilities Department],

More information

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4 I N D U S T R I A L rev. A- INSTALLATION INSTRUCTIONS *PENDING* E77827 E77827 APPLICATION MR3 & MR6 Luminaires are suitable for use in the following areas as defined by the National Electrical Code (NEC)

More information

Agenda. TS2 Cabinet Components and Operation. Understanding a Signal Plan Maccarone. Basic Preemption/Priority

Agenda. TS2 Cabinet Components and Operation. Understanding a Signal Plan Maccarone. Basic Preemption/Priority Morning Traffic Terminology TS2 Cabinet Components and Operation Traffic Signal Phasing Ring Structure Traffic Signal Timing Understanding a Signal Plan Maccarone Controller Programming Afternoon Basic

More information

REVISIONS INDEX 2016 ROAD & BRIDGE STANDARDS

REVISIONS INDEX 2016 ROAD & BRIDGE STANDARDS REVISIONS INDEX 2016 ROAD & BRIDGE STANDARDS December 2018 Revision Letter September 2018 Revision Letter September 2017 Revision Letter August 2017 Revision Letter February 2017 Revision Letter Signature

More information

Antennas and Wireless Accessories

Antennas and Wireless Accessories Antennas and Wireless Accessories Description Page No. Antennas and Wireless Accessories see pages 1430 1434 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2010 Cooper Crouse-Hinds

More information

Founded 1990 Located in Lancaster NY (near Buffalo) Systems integration and wireless technology development history.

Founded 1990 Located in Lancaster NY (near Buffalo) Systems integration and wireless technology development history. Founded 1990 Located in Lancaster NY (near Buffalo) Systems integration and wireless technology development history. Acquired assets and exclusive rights to Aria Wireless and GLB Electronics product line

More information

1 of REV:0

1 of REV:0 1 of 5 683-10573-0418 This specification sets forth the minimum requirements for purchase and installation of an aboveground Radar Advance Detection Device (RADD) system for a real-time, advance vehicle-detection

More information

Wireless Base Radio. Wireless Transmitters

Wireless Base Radio. Wireless Transmitters XYR 5000 Wireless Base Radio 34-XY-03-55 9/2006 WBR/WBH Europe PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE Function The Wireless Base Radio (WBR) is part of the XYR 5000 family of wireless products.

More information

F-4 FURNITURE. Contents

F-4 FURNITURE. Contents Contents F-4-1 Public Art Pole F-4-2 Banner Pole F-4-3 Typical Banner Installation F-4-4a Banner/Flower Basket Pole F-4-4b Banner/Flower Basket Pole F-4-5 Flower Basket Brackets F-4-6 TTC Station Sign

More information

Argo and Delphi. Delphi. Argo span-wire installation. Argo. products.iguzzini.com/argo_line products.iguzzini.com/delphi_line

Argo and Delphi. Delphi. Argo span-wire installation. Argo. products.iguzzini.com/argo_line products.iguzzini.com/delphi_line Delphi Argo span-wire installation Argo 12000 10000 9000 8000 7000 5000 La venaria ø1411 anello ø900 ufo 423-634 crown ø664 iteka 195x270 platea 250x370 flaminia 340 415x758 505x807 307x620 wow archilede

More information

RCF 3.4. Portable Traffic Signal - Technical Specifications. North America Traffic Inc REV#

RCF 3.4. Portable Traffic Signal - Technical Specifications. North America Traffic Inc REV# RCF 3.4 Portable Traffic Signal - Technical Specifications Signal Controller Hardware Each signal controller shall be capable of providing the following feedback information to the user: Audible low battery

More information

Guardian Pedestrian Signal Installation Manual

Guardian Pedestrian Signal Installation Manual Guardian Pedestrian Signal Installation Manual 906-0030 Revision A May 31, 2017 Campbell Company 450 W. McGregor Drive Boise, Idaho 83705 USA Tel: +1-208-345-7459 Fax: + 1-208-345-7481 Last edited: 31

More information

Ohio Department of Transportation Office of Roadway Engineering January 18, 2013

Ohio Department of Transportation Office of Roadway Engineering January 18, 2013 Ohio Department of Transportation Office of Roadway Engineering January 18, 2013 To: Holders of the Traffic Standard Construction Drawings (SCDs) and Plan Insert Sheets (PISs) As of January 18, 2013, eighteen

More information

Array Solutions OCF Series Dipoles

Array Solutions OCF Series Dipoles OCF Series Dipoles Fig 1 Thank you and congratulations on your purchase of the, Off- Center Fed HF Dipole Antenna System. This antenna was built with the same quality workmanship and attention to detail

More information

Section. DEVELOPMENT STANDARDS City of Ellensburg ILLUMINATION STANDARDS

Section. DEVELOPMENT STANDARDS City of Ellensburg ILLUMINATION STANDARDS Section 8 City of Ellensburg ILLUMINATION STANDARDS Table of Contents STREET ILLUMINATION...3-5 GENERAL NOTES...3 INSTALLATION AND CONNECTIONS...3 MARKING...3 STAKING...3-4 TRENCH REQUIREMENTS...4 ILLUMINATION

More information

TECHNICAL SPECIAL PROVISIONS

TECHNICAL SPECIAL PROVISIONS TECHNICAL SPECIAL PROVISIONS FOR CITY OF TALLAHASSEE ADVANCED TRANSPORTATION MANAGEMENT SYSTEM OCTOBER 2004 TECHNICAL SPECIAL PROVISIONS FOR CITY OF TALLAHASSEE ADVANCED TRANSPORTATION MANAGEMENT SYSTEM

More information

MACOMB COUNTY TRAFFIC SIGNAL DETAILS. Michigan Department of Transportation. Traffic and Safety MC-026A THROUGH MC-120A ENGLISH VERSION

MACOMB COUNTY TRAFFIC SIGNAL DETAILS. Michigan Department of Transportation. Traffic and Safety MC-026A THROUGH MC-120A ENGLISH VERSION Traffic and Safety MACOMB COUNT TAFFIC SINAL DETAILS MC-026A THOUH MC-120A Disclaimer: The information provided is a product of the Michigan Department of Transportation (MDOT) and is intended for your

More information

SUBJECT: Standard Plate Turf Establishment Areas (at Pipe Culvert Ends)

SUBJECT: Standard Plate Turf Establishment Areas (at Pipe Culvert Ends) MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Program Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (14-01) MANUAL: Standard

More information

The quality you expect at the price you want to pay. Available at: 1 (888) (866)

The quality you expect at the price you want to pay. Available at:   1 (888) (866) The quality you expect at the price you want to pay Available at: www.wirelessource.ca 1 (888) 430-0660 1 (866) 244-4844 October 2014 VHF Mobile Antennas... P1-5 UHF Mobile Antennas... P6-9 CB Mobile Antennas...

More information

SPECIAL SPECIFICATION 8590 Emergency Vehicle Traffic Signal Priority Control System

SPECIAL SPECIFICATION 8590 Emergency Vehicle Traffic Signal Priority Control System 2004 Specifications CSJ 0002-01-074, etc. SPECIAL SPECIFICATION 8590 Emergency Vehicle Traffic Signal Priority Control System 1. Description. This Item governs the furnishing and installation of emergency

More information

2. Remove from the Standard Plate manual: Standard Plate Index, Sheets 1-4 of 4, Numerical Index of Standard Plates (August 31, 2012)

2. Remove from the Standard Plate manual: Standard Plate Index, Sheets 1-4 of 4, Numerical Index of Standard Plates (August 31, 2012) MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Program Management & Technical Support, Design Support Section TRANSMITTAL LETTER NO. (12-04) MANUAL: Standard

More information

A. Product Description: Stranded conductor insulated wire.

A. Product Description: Stranded conductor insulated wire. SECTION 16120CPPR CONDUCTORS AND CABLE PART 1 - GENERAL 1.1 SYSTEM DESCRIPTION A. Product Requirements: Provide products as follows: 1. All building wire shall be stranded copper (no aluminum wire). 2.

More information

Ground Clamps Cable Tray

Ground Clamps Cable Tray commercial and industrial fittings: ing Fittings and Solderless Connectors Clamps Cable Tray Terminates ground wire to cable tray. For aluminum or copper conductors. 1 4 hex wrench tightens both tray and

More information

Standard Plate 7036 is discontinued. It is replaced by Standard Plan Pedestrian Curb Ramp Details.

Standard Plate 7036 is discontinued. It is replaced by Standard Plan Pedestrian Curb Ramp Details. DEVELOPED BY: Design Standards ISSUED BY: Office of Program Management & Technical Support, Design Support Section TRANSMITTAL LETTER NO. (12-02) MANUAL: Standard Plates DATED: May 11, 2012 SUBJECT: Standard

More information

CHAPTER 29 PROJECT COMPLETION DOCUMENTS

CHAPTER 29 PROJECT COMPLETION DOCUMENTS CHAPTER 29 PROJECT COMPLETION DOCUMENTS PROJECT COMPLETION Upon completion of traffic control signal system and lighting projects, there are forms and checklists to ensure that the project is closed out

More information

Cisco Aironet Omnidirectional Mast Mount Antenna (AIR-ANT2506)

Cisco Aironet Omnidirectional Mast Mount Antenna (AIR-ANT2506) Cisco Aironet Omnidirectional Mast Mount Antenna (AIR-ANT2506) This document outlines the specifications, describes the omnidirectional mast mount antenna, and provides instructions for mounting it. Designed

More information

DA - DISTRIBUTION AUTOMATION

DA - DISTRIBUTION AUTOMATION DA - DISTRIBUTION AUTOMATION DA Drawing & CU Revision List CU DATE REVISION OF REVISION DA5_RM6 DA6_RM6 DA6_RM6_T200 DA6_RM6_T200 DA6_RM6_T200 DA1 DA2 DA3 DA4 DA3_150MHZ DA3_450MHZ Sept 2002 July 2006

More information

Instruction Manual for 98cm Elliptical Ka Antenna

Instruction Manual for 98cm Elliptical Ka Antenna Instruction Manual for 98cm Elliptical Ka Antenna 98cm WB Issue 03 Caution This instruction leaflet will assist you in the correct installation of the product. Read it prior to starting any installation

More information

Customer Requirements RF Antenna Installations

Customer Requirements RF Antenna Installations Application Terms Attachment requirements and clearances on the Pole for Radio Frequency (RF) antenna equipment installations. This standard is intended to allow electrical workers to perform their normal

More information

Cisco Aironet 13.5-dBi Yagi Mast Mount Antenna (AIR-ANT1949)

Cisco Aironet 13.5-dBi Yagi Mast Mount Antenna (AIR-ANT1949) Cisco Aironet 13.5-dBi Yagi Mast Mount Antenna (AIR-ANT1949) Overview This document describes the 13.5-dBi Yagi mast mount antenna and provides instructions for mounting it. The antenna operates in the

More information

Apr - 12, 05. Most recent REV DATE : page #

Apr - 12, 05. Most recent REV DATE : page # Customer : P.O. number : Dewar number : Job Order number : Quote number : Components : GUMP Preamp, configured for 2 channels, includes external Analog, Digital and Power Supply cables Most recent REV

More information

Cisco Aironet 14-dBi Patch Antenna (AIR-ANT5114P-N)

Cisco Aironet 14-dBi Patch Antenna (AIR-ANT5114P-N) Cisco Aironet 14-dBi Patch Antenna (AIR-ANT5114P-N) This document outlines the specifications for the Cisco Aironet 14-dBi Patch Antenna (AIR-ANT5114P-N) and provides instructions for mounting it. The

More information

Quick Start Guide.indd 1 05/11/15 10:07

Quick Start Guide.indd 1 05/11/15 10:07 015-10-19 Quick Start Guide.indd 1 05/11/15 10:07 1 WELCOME TO TRACKMAN Congratulations on the purchase of your TrackMan 4. This guide shows you what your TrackMan can do, helps you set it up, and gets

More information

TRANSMITTAL LETTER. As Builts Change Order Contract Copy of Letter Insurance. For approval Approved as submitted Resubmit copies for approval

TRANSMITTAL LETTER. As Builts Change Order Contract Copy of Letter Insurance. For approval Approved as submitted Resubmit copies for approval Redwood City Electric, Inc. TRANSMITTAL LETTER To: Transworld Construction, Inc. 1178 Folsom Street San Francisco, CA 94103 Date: 05/31/12 Job #: 9340 Regarding: SFO DATA CENTER Attn: Rob Acero We are

More information

Accutech AP10. Wireless absolute pressure field unit

Accutech AP10. Wireless absolute pressure field unit Accutech AP10 Wireless absolute pressure field unit 1 The Accutech AP10 wireless absolute pressure field unit provides pressure data in a variety of ranges from 30 to 250PSIA. With its integrated and highly

More information

Appendix Traffic Engineering Checklist - How to Complete. (Refer to Template Section for Word Format Document)

Appendix Traffic Engineering Checklist - How to Complete. (Refer to Template Section for Word Format Document) Appendix 400.1 Traffic Engineering Checklist - How to Complete (Refer to Template Section for Word Format Document) Traffic Engineering Checksheet How to Complete the Form June 2003 Version 3 Maintained

More information

SUBJECT: Standard Plates 4132, 4155, Drainage Structures and Castings Info

SUBJECT: Standard Plates 4132, 4155, Drainage Structures and Castings Info MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Project Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (18-01) MANUAL: Standard

More information

INSTRUCTIONS: 1. Record the transmittal letter number, date, and subject on the transmittal record sheet located in the front of the manual.

INSTRUCTIONS: 1. Record the transmittal letter number, date, and subject on the transmittal record sheet located in the front of the manual. MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Technical Support Design Services Section TRANSMITTAL LETTER NO. (0-03) MANUAL: Standard Plates DATED: September

More information

Yield Sign, R1-2 w/ Black Back. Size SF PNC 30=30 36=36. Curve Right Sign, W1-2R w/ Black Back. Size SF PNC 24=24.

Yield Sign, R1-2 w/ Black Back. Size SF PNC 30=30 36=36. Curve Right Sign, W1-2R w/ Black Back. Size SF PNC 24=24. Regulatory Signs MUTCD Compliant Stop Sign, R1-1 w/ Black Back SF-6000 - - - PNC Yield Sign, R1-2 w/ Black Back SF-2025 - - - PNC No Outlet Sign, W14-2 w/ Black Back SF-2033 - - - PNC Dead End, W14-1 w/

More information

Manhole or Catch Basin Type A & B Cone Sections Precast - Design F Manhole or Catch Basin Cover (Reducer Cone Section Precast) Design D

Manhole or Catch Basin Type A & B Cone Sections Precast - Design F Manhole or Catch Basin Cover (Reducer Cone Section Precast) Design D MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Program Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (14-02) MANUAL: Standard

More information

SUBJECT: Standard Plate 9102 Turf Establishment Areas At Pipe Culvert Ends

SUBJECT: Standard Plate 9102 Turf Establishment Areas At Pipe Culvert Ends MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Project Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (17-03) MANUAL: Standard

More information

INTERMEDIATE METAL CONDUIT

INTERMEDIATE METAL CONDUIT PRODUCT GUIDE 08 CONDUIT PIPES CONDUIT FITTINGS FITTINGS FOR FLEXIBLE CONDUITS METALLIC ELECTRICAL BOXES AND COVERS CONDUIT BODIES WEATHERPROOF BOXES AND COVERS CHANNELS & SUPPORTS METAL ENCLOSURES CHANNELS

More information

HP ProCurve 6.9/7.7dBi Dual Band Directional Antenna (J8999A) Guide

HP ProCurve 6.9/7.7dBi Dual Band Directional Antenna (J8999A) Guide HP ProCurve 6.9/7.7dBi Dual Band Directional Antenna (J8999A) Guide SAFETY The HP ProCurve J8999A and all associated equipment should be installed in accordance with applicable local and national electrical

More information

CONTINUING EDUC ATION

CONTINUING EDUC ATION 3 CONTINUING EDUC ATION FOR WISCONSIN ELECTRICIANS 2017 NEC Article 250 2 Hours WISCONSIN CONTRACTORS INSTITUTE N16 W23217 Stone Ridge Drive Suite 290 Waukesha, WI 53188 262-409-4282 www.wcitraining.com

More information

Pole Line Hardware. Heavy-Duty Spool Rack (200 A) No. of Wires. Anti-Vibration Kit for Spool Rack. Heavy-Duty Spool Rack (400 A) No.

Pole Line Hardware. Heavy-Duty Spool Rack (200 A) No. of Wires. Anti-Vibration Kit for Spool Rack. Heavy-Duty Spool Rack (400 A) No. Heavy-Duty Spool Rack (200 A) SS401E - SS802E - SS803E - SS804E No. of Wires Overall Length SS401E 1 9-1/2 300 136.3 10 SS802E 2 17-1/2 520 236.3 SS803E 3 25-1/2 780 354.5 5 SS804E 4 33-1/2 1040 472.7

More information

Outdoor Enclosure. VIVOTEK Pan/Tilt & Fixed Dome Series. Installation Guide

Outdoor Enclosure. VIVOTEK Pan/Tilt & Fixed Dome Series. Installation Guide VIVOTEK Pan/Tilt & Fixed Dome Series Outdoor Enclosure Using AE-131/-132 Outdoor Enclosure, AE-151 Outdoor Enclosure, AM-114 Pendant Head (outdoor), AM-116 and AM-117 Pendant Pipes, AM-221 Gooseneck, AM-212

More information

siemens.com/mobility Sitraffic Wimag Easy, reliable and cost-effective traffic and parking space monitoring

siemens.com/mobility Sitraffic Wimag Easy, reliable and cost-effective traffic and parking space monitoring siemens.com/mobility Easy, reliable and cost-effective traffic and parking space monitoring Our family of detectors: state-of-the-art detection and wireless technology Compact dimensions (7.5 7.5 5.0 cm),

More information

SEL Phase Comparison Faulted Circuit Indicator (PC FCI) Communicates to line crews using the. Features and Benefits

SEL Phase Comparison Faulted Circuit Indicator (PC FCI) Communicates to line crews using the. Features and Benefits SEL-8 Phase Comparison ed Circuit Indicator (PC FCI) SEL-8 SEL-8 SEL-8 SEL-8 SEL-8 SEL-8 Communicates to line crews using the Features and Benefits Locates ed Cable Sections Quickly Locate cable failures

More information

Application Y Y N 2 N N Y N 2 N 2 Y Y N 2 N N N 2 Y N 2 Y 1 Y 1 Y 1 Y 1 N Y 1 Y 1 Y 1 Y Y N N N Y N 2 N N 2 N 2 Y N N N 2 N 2 Y N N Y N N N N Y

Application Y Y N 2 N N Y N 2 N 2 Y Y N 2 N N N 2 Y N 2 Y 1 Y 1 Y 1 Y 1 N Y 1 Y 1 Y 1 Y Y N N N Y N 2 N N 2 N 2 Y N N N 2 N 2 Y N N Y N N N N Y >ETM Antenna Range< Application Applicable Product ETM Item No. Antenna Type 3G 4G RF 900MHz Wifi 2.4GHz Wifi 5GHz ETM Serial Modem FME Digi Cellular SMA Digi RF or Wifi RPSMA ETM70000N00 Antenna, 3G Cellular

More information

Cisco Aironet Dual-Band MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2544V4M-R)

Cisco Aironet Dual-Band MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2544V4M-R) Cisco Aironet Dual-Band MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2544V4M-R) This document outlines the specifications for the Cisco Aironet 2.4-GHz/5-GHz Dual-Band MIMO Wall-Mounted Omnidirectional

More information

System Components and Accessories

System Components and Accessories OutBack Panel Mount Breakers Panel mounted hydraulic-magnetic type breakers that can be used for DC sources, inverters or load circuits. Model Current Voltage Branch Terminals Width Rating Rating Circuit

More information

Acuity. Acuity. AP620 Profile Measurement Scanner. Principles of Operation. Definitions. Typical Scanner Applications

Acuity. Acuity. AP620 Profile Measurement Scanner. Principles of Operation. Definitions. Typical Scanner Applications The AP620 profile measurement scanner is s short-range laser scanner for industrial contour and shape measuring applications. The laser profile scanner quickly and accurately generates 2D or 3D profile

More information

(SMS MOUNT SHOWN) Prefix Mounting Optics Lamp Wattage Length Volts Finish Options & Accessories 14W 21W 28W 2' 3', 6' 4', 8' T5HO 2' 3', 6' 4', 8'

(SMS MOUNT SHOWN) Prefix Mounting Optics Lamp Wattage Length Volts Finish Options & Accessories 14W 21W 28W 2' 3', 6' 4', 8' T5HO 2' 3', 6' 4', 8' (SMS MOUNT SHOWN) Prefix Mounting Optics Lamp Wattage Length Volts Finish Options & Accessories SMS - surface mount single fixture SMM - surface mount multiple fixtures EAS - extended arm single fixture

More information

DESIGN AND DEVELOPMENT STANDARDS FOR WIRELESS FACILITIES IN THE PUBLIC RIGHTS-OF-WAY

DESIGN AND DEVELOPMENT STANDARDS FOR WIRELESS FACILITIES IN THE PUBLIC RIGHTS-OF-WAY DESIGN AND DEVELOPMENT STANDARDS FOR WIRELESS FACILITIES IN THE PUBLIC RIGHTS-OF-WAY The following Design and Development Standards are subject to change at any time at the sole discretion of the City

More information

LED Wattage. Color Temp. 350 ma 35LA 55LA 70LA 90LA ma 50LA 80LA 105LA ma 140LA ma 75LA 105LA LA

LED Wattage. Color Temp. 350 ma 35LA 55LA 70LA 90LA ma 50LA 80LA 105LA ma 140LA ma 75LA 105LA LA ELA Project: Location: Cat.No: Type: Qty: Notes: 16" area luminaire Philips Stonco s ELA luminaires combine low profile style, advanced LED performance and advanced thermal management technology to deliver

More information

IMMS-CI-HW. Communications Controller Interface. Installation Instructions IMMS. Controller. Interface. AC From Transformer 24 VAC REM 24 VAC SEN

IMMS-CI-HW. Communications Controller Interface. Installation Instructions IMMS. Controller. Interface. AC From Transformer 24 VAC REM 24 VAC SEN CI 4 Comm. IMMS-CI-HW Communications Interface POWER From Transformer Ground To REM Installation Instructions To SmartPort Sensor 1 Sensor 2 Sensor 3 From Sensors Sensor Common IMMS Interface From SI or

More information

SPECIAL SPECIFICATION 1123 GPS Emergency Vehicle Traffic Signal Priority Control System

SPECIAL SPECIFICATION 1123 GPS Emergency Vehicle Traffic Signal Priority Control System 2004 Specifications CSJ 0922-11-039 SPECIAL SPECIFICATION 1123 GPS Emergency Vehicle Traffic Signal Priority Control System 1. Description. This Item governs the furnishing and installation of emergency

More information

230/26kV Brandy Branch T2 Substation Addition JEA ITEM QTY. DESCRIPTION MFG. TYPE OR CAT. NO.

230/26kV Brandy Branch T2 Substation Addition JEA ITEM QTY. DESCRIPTION MFG. TYPE OR CAT. NO. of 8 20KV GALVANIZED STEEL STRUCTURE A 6 20KV BUS SUPPORT STAND, Ø LOW, 20'-0" BUS HEIGHT APPX WT = 766 LBS EA C 4 20KV BUS SUPPORT STAND, -PHASE, HIGH, 0'-0" BUS HEIGHT '-0" PHASE SPACING REF. 5262 APPX

More information

Model LS 250 Loop Scanner Operator s Manual. Version

Model LS 250 Loop Scanner Operator s Manual. Version Model LS 250 Loop Scanner Operator s Manual Version 05-2011 Contents 1. Introduction...2 2. Description...3 2.1 Model Nomenclature...3 2.2 Operating Principle...3 2.3 Specifications...5 3. Location and

More information

Accutech GP10. Wireless gauge pressure field unit

Accutech GP10. Wireless gauge pressure field unit Accutech GP10 Wireless gauge pressure field unit 1 The Accutech GP10 wireless gauge pressure field unit provides pressure data in a variety of ranges from 250 to 10000 PSIG. With its integrated and highly

More information

112" 72" 40" BIKE LANE MARKING SHARED LANE MARKING PAVEMENT MARKING DETAILS N.T.S. GENERAL NOTES

112 72 40 BIKE LANE MARKING SHARED LANE MARKING PAVEMENT MARKING DETAILS N.T.S. GENERAL NOTES 8 SB RTE ON RAMP " 0" GENERAL NOTES 7" SHARED LANE MARKING ' ' ' BIKE LANE MARKING PAVEMENT MARKING DETAILS N.T.S. YIELD LINE. ALL SIGNS SHALL HAVE A MINIMUM CLEARANCE BETWEEN THE EDGE OF SIGN AND THE

More information

Diamond Knowledge Base. Inductive Loop Guide. Introduction

Diamond Knowledge Base. Inductive Loop Guide. Introduction Diamond Knowledge Base Inductive Loop Guide Introduction An inductive loop is basically a metal detector installed in the surface of the roadway. It consists of electrical wire embedded in the roadway,

More information

Phone: Fax: Large Inventory Quick Delivery Knowledgeable Staff Competitive Pricing

Phone: Fax: Large Inventory Quick Delivery Knowledgeable Staff Competitive Pricing Pole Bracket Mounting Hardware Seasonal Decorations Banner Flag Municipal Car Dealers Traffic Signal Shopping Centers Gas Stations Security Cameras Clamp/Straps Stainless Steel Snap Locking Style Clamps/Straps

More information

AWS High Gain Omni-Directional Remote Antenna User Guide 1210

AWS High Gain Omni-Directional Remote Antenna User Guide 1210 High Gain Omni-Directional Antenna User Guide WI-ANT-P6 WI-ANT-P6-A-10 WI-ANT-P6-A-25 For Models: Omni-Directional 6 dbd Pole remote antenna Omni 6 dbd remote antenna w/lightning arrestor & 10 ft cable

More information

Operation Manual February Opticom Infrared System

Operation Manual February Opticom Infrared System Operation Manual February 2008 Opticom Infrared System M195/196, M9192, M292, M9592, M592 Emitters M511, M521, M522 Detectors M262, M562 Phase Selectors M360, M560 System Chassis M5168, M5575 Interface

More information

Becker Mining Systems

Becker Mining Systems Becker Mining Systems Tagging and Tracking in Underground Mining BECKERTAG System Principle FUNCTIONAL FEATURES Vehicle, Beacon, Personnel Tags Pseudo Random Transmission Unique ID Number Battery Status

More information

Cisco Aironet 2.4-GHz/5-GHz MIMO 4-Element Patch Antenna (AIR-ANT2566P4W-R)

Cisco Aironet 2.4-GHz/5-GHz MIMO 4-Element Patch Antenna (AIR-ANT2566P4W-R) Cisco Aironet 2.4-GHz/5-GHz MIMO 4-Element Patch Antenna (AIR-ANT2566P4W-R) This document outlines the specifications for the Cisco Aironet 2.4-GHz/5-GHz MIMO 4-Element Patch Antenna (AIR-ANT2566P4W-R)

More information

Accessible Pedestrian Signals APS

Accessible Pedestrian Signals APS Accessible Pedestrian Signals APS By Zane Sapp Campbell Company 4/29/2015 Pedsafety.com 1 Outline What is APS? What does ADA require? Where is APS made? Understanding APS (MUTCD) When to Install APS Designing

More information

Portable Signals: INDOT Design Guidance and Specifications

Portable Signals: INDOT Design Guidance and Specifications : INDOT Design Guidance and Specifications Joe Bruno, P.E. Traffic Administration, INDOT March 7, 2017 Presentation Overview Background Design Manual 83-5.0 and Design Memo 16-06 Cost and Pay Item Info

More information

Houston Radar LLC. Installation and User Manual For. Doppler Radar DR-1500

Houston Radar LLC. Installation and User Manual For. Doppler Radar DR-1500 Houston Radar LLC Installation and User Manual For Doppler Radar DR-1500 Houston Radar LLC 13814 Sherburn Manor Dr. Cypress.TX Http://www.Houston-Radar.com Email: sales@houston-radar.com Contact: (281)

More information

Installation requirements

Installation requirements Installation requirements for SUNNY CENTRAL 500U 1 Contents This document describes the requirements which have to be observed for the installation site of the Sunny Central 500U. The installation and

More information

Tensile Strength (minimum) Yield Strength at 0.2% offset (minimum) 55,000 psi Elongation: 8 min. 18% 2 min. 21%

Tensile Strength (minimum) Yield Strength at 0.2% offset (minimum) 55,000 psi Elongation: 8 min. 18% 2 min. 21% S-800 TRAFFIC SIGNALS: This work shall include the furnishing of all labor, materials and equipment for the installation of a complete operational traffic signal installation in accordance with the plans

More information

RF Connectors Technical Data Sheet. Gold over Nickel Plated Beryllium Copper Contact. Size in [11.81 mm] . Weight lbs [3.18 g].

RF Connectors Technical Data Sheet. Gold over Nickel Plated Beryllium Copper Contact. Size in [11.81 mm] . Weight lbs [3.18 g]. RP SMA Male Connector Solder Attachment for PE-SR402AL, PE-SR402FL, PE-SR402FLJ, PE- SR402TN, RG402, Gold Plated Brass Body RF Connectors Technical Data Sheet PE44724 Configuration SMA Male Reverse Polarity

More information

230/26kV Steelbald T3 Replacement project ITEM QTY. DESCRIPTION MFG. TYPE OR CAT. NO.

230/26kV Steelbald T3 Replacement project ITEM QTY. DESCRIPTION MFG. TYPE OR CAT. NO. 1 of 5 230KV BUS MATERIALS AND STRUCTURES K5 120 954 MCM AAC, 37 STRAND, CODE NAME "MAGNOLIA" MID STATE A954-01BA01 K6 35 4/0 AAC, 7 STR., CODE NAME "OXLIP" MID STATE AAC N32 12 TERMINAL, 954 MCM AAC TO

More information

A family of architectural luminaries for the security and comfort of people in outdoor spaces. Classics Series

A family of architectural luminaries for the security and comfort of people in outdoor spaces. Classics Series A family of architectural luminaries for the security and comfort of people in outdoor spaces Classics Series Keene MAKES LIGHT WORK Families offer us variety of character, and diversity within a common

More information

Article 700: Emergency Systems. 2.! Audible and visual signal devices shall be provided, where practicable to indicate.

Article 700: Emergency Systems. 2.! Audible and visual signal devices shall be provided, where practicable to indicate. Part N: Code Book Questions Article 700: Emergency Systems 1.! For emergency systems, the authority having jurisdiction shall conduct or witness a test on the! complete system upon installation and periodically

More information

CONSTRUCTION SPECIFICATION FOR TRAFFIC ACTUATION EQUIPMENT

CONSTRUCTION SPECIFICATION FOR TRAFFIC ACTUATION EQUIPMENT ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS.PROV 623 April 2017 CONSTRUCTION SPECIFICATION FOR TRAFFIC ACTUATION EQUIPMENT TABLE OF CONTENTS 623.01 SCOPE 623.02 REFERENCES 623.03 DEFINITIONS

More information

Accutech DP20. Wireless differential pressure field unit

Accutech DP20. Wireless differential pressure field unit Accutech DP20 Wireless differential pressure field unit 1 The Accutech DP20 differential pressure field unit provides differential pressure data in a variety of ranges up to +/-300in H 2 0. Both traditional

More information

City of Calgary, Alberta

City of Calgary, Alberta City of Calgary, Alberta An Encom Then and Now Success Story The Challenge Boomtown needed innovative solution Calgary is known worldwide as the Stampede City, thanks to its annual 10-day rodeo and Western

More information

Portable Antenna Spike Mount (CHA SPIKE MOUNT) Operator s Manual

Portable Antenna Spike Mount (CHA SPIKE MOUNT) Operator s Manual Portable Antenna Spike Mount (CHA SPIKE MOUNT) Operator s Manual Nevada - USA WWW.CHAMELEONANTENNA.COM VERSATILE DEPENDABLE STEALTH BUILT TO LAST Table of Contents Introduction... 3 Parts of the Spike

More information

Communicator II WIRELESS DATA TRANSCEIVER

Communicator II WIRELESS DATA TRANSCEIVER Communicator II WIRELESS DATA TRANSCEIVER C O M M U N I C A T O R I I The Communicator II is a high performance wireless data transceiver designed for industrial serial and serial to IP networks. The Communicator

More information

Cisco Aironet 5-dBi Diversity Omnidirectional Antenna (AIR-ANT2452V-R)

Cisco Aironet 5-dBi Diversity Omnidirectional Antenna (AIR-ANT2452V-R) Cisco Aironet 5-dBi Diversity Omnidirectional Antenna (AIR-ANT2452V-R) This document outlines the specifications for the Cisco Aironet 5-dBi Diversity Omnidirectional Antenna (AIR-ANT2452V-R) and provides

More information

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR WIRELESS INTERCONNECT FOR SIGN MOUNTED FLASHER

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR WIRELESS INTERCONNECT FOR SIGN MOUNTED FLASHER MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR WIRELESS INTERCONNECT FOR SIGN MOUNTED FLASHER OPR:DJA 1 of 5 C&T:APPR:JAR:DBP:09-01-11 FHWA:APPR:09-01-11 a. Description. This work consists

More information

A. Deviation from this standard must be approved by the Project Architect.

A. Deviation from this standard must be approved by the Project Architect. September 2012, rev. 00 26 5600 Exterior Lighting PART 1. GENERAL 1.01 Related Documents A. Deviation from this standard must be approved by the Project Architect. B. Drawings and general provisions of

More information

DOCK WEDGE - STANDARD

DOCK WEDGE - STANDARD DOCK WEDGE - STANDARD INSTALLATION INSTRUCTIONS WOOD HEADER READ ALL INSTRUCTIONS BEFORE INSTALLING SEAL. SUPER SEAL MFG. LTD. WILL NOT BE HELD RESPONSIBLE FOR IMPROPER INSTALLATION OF ANCHORING DEVICES,

More information

SECTION COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION

SECTION COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION SECTION 16715 COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION PART 1 - GENERAL 1.01 SECTION DESCRIPTION AND BASIC REQUIREMENTS A. The Electrical Power Distribution System provides power distribution from

More information

Wisconsin Contractors Institute Continuing Education

Wisconsin Contractors Institute Continuing Education IMPORTANT NOTE: You should have received an email from us with a link and password to take your final exam online. Please check your email for this link. Be sure to check your spam folder as well. If you

More information

Designed for flexibility and performance, wherever people need durable outdoor luminaries. Paraflood Series

Designed for flexibility and performance, wherever people need durable outdoor luminaries. Paraflood Series Designed for flexibility and performance, wherever people need durable outdoor luminaries Paraflood Series Keene MAKES LIGHT WORK Change The one constant of which we can all be sure. As buildings mature

More information