Measurement & Control of energy systems. Teppo Myllys National Instruments

Size: px
Start display at page:

Download "Measurement & Control of energy systems. Teppo Myllys National Instruments"

Transcription

1 Measurement & Control of energy systems Teppo Myllys National Instruments

2 National Instruments Direct operations in over 50 Countries More than 1,000 products, employees, and 700 Alliance Program Members Corporate headquarters in Austin, Texas Applications and Field Engineers Distributors NI Data Acquisition Technology Update 2

3 What We Do Low-Cost Modular Measurement and Control Hardware Productive Software Development Tools Highly Integrated Systems Platforms Used By Engineers and Scientists for Test, Design and Control 3

4 Graphical System Design LEGO Education WeDo Hands-on Learning for 7 year-olds CERN Large Hadron Collider the most powerful instrument on earth 4

5 INDUSTRIAL Internet of Things CONSUMER Internet of Things SMART SMART Factory Phone Grid Machine Connectivity Data Analytics Wearable TV City Appliances Car Home Based on Moor Insights & Strategy's report "Segmenting the Internet of Things (IoT)" 5

6 Agenda Introduction to Data Acquisition Signal Conditioning Data Acquisition Hardware Buses (USB, PCI(e), Ethernet) Form Factor Modularity and Integration Software Integration Measurement services (drivers etc.) Programming languages 6

7 What Is Data Acquisition (DAQ)? Data acquisition (DAQ) is the process of measuring an electrical or physical phenomenon such as voltage, current, temperature, pressure, or sound with a computer. Compared to traditional measurement systems, PC-based DAQ systems exploit the processing power, productivity, display, and connectivity of industry-standard computers providing a more powerful, flexible, and cost-effective measurement solution. 7

8 Signals Come in Two Forms: Digital and Analog Digital Analo g 8

9 Signals Come in Two Forms: Digital and Analog Digital Analo g 9

10 Analog Signals Analog signals are continuous signals that can be any value with respect to time. 10

11 Analog Terminology 4.71 V Level The instantaneous value of the signal at a given point in time. Shape The form that the analog signal takes, which often dictates further analysis that can be performed on the signal. Frequency The number of occurrences of a repeating event over time. 11

12 The Three R s of Data Acquisition: Resolution Resolution Range Rate 6-Bit Resolutio n Original Signal 3-Bit Resolutio n 12

13 The Three R s of Data Acquisition: Range Resolution Range Rate Range of -2V-10V to 2V to 10V Original Signal 3-Bit Resolutio n 13

14 The Three R s of Data Acquisition: Rate Resolution Range Rate Original Waveform (10 Hz) Sampling Rate = Hz 14

15 DEMO: Effects of sampling rate vs. signal frequency (Time domain) 15

16 Following the Nyquist Theorem Prevents Aliasing Frequency To accurately represent the frequency of your original signal You must sample at greater than 2 times the maximum frequency component of your signal. Shape To accurately represent the shape of your original signal You must sample between 5 10 times greater than the maximum frequency component of your signal. 16

17 The Nyquist Theorem in Action Aliased Signal 100 Hz Sine Wave 100 Hz Sine Wave 100 Hz Sine Wave Sampled at 100 Hz Sampled at 200 Hz Sampled at 1 khz Adequately Sampled for Frequency Only Adequately Sampled for Both Frequency and Shape 17

18 DEMO: Effects of sampling rate vs. signal frequency (Frequency domain) 18

19 Conditioning Signals for Quality Measurements Signal conditioning improves a signal that is difficult for your DAQ device to measure Signal conditioning is not always required Signal Conditioning Noisy, Low-Level Signal Filtered, Amplified Signal 19

20 Common Signal Conditioning Examples Transducer/Signals Signal Conditioning Thermocouples Amplification, Linearization, Cold-Junction Compensation RTD (Resistance Temperature Detector) Current Excitation, Linearization Strain Gage Voltage Excitation, Bridge Configuration, Linearization Common Mode or High Voltage Isolation Amplifier Loads Requiring AC Switching or Large Current Flow High-Frequency Noise Electromechanical Relays or Solid-State Relays Low-Pass Filters 20

21 Examining Common Signal Conditioning for Voltage Measurements Amplification Attenuation Filtering Isolation 21

22 Amplification Used on low-level signals Maximizes use of analog-to-digital converter (ADC) range and increases accuracy Increases signal-to-noise ratio (SNR) Amplifier 22

23 Attenuation Decreases the input signal amplitude to fit within the range of the DAQ device Necessary when input signal voltages are beyond the range of the DAQ device Attenuator 23

24 Filtering Filters remove unwanted noise from a measured signal and block unwanted frequencies Time Domain Lowpass Filter Time Domain Frequency Domain Frequency Domain 24

25 DEMO: Filtering 25

26 Isolation Isolation helps to pass a signal from its source to a measurement device without a direct physical connection Blocks high common-mode signals Breaks ground loops Protects your instrumentation Electromagnetic Isolation Capacitive Optical 26

27 Data Acquisition Hardware 27

28 Architecture of an Integrated Measurement System NI CompactDAQ hardware combines a 1-, 4-, or 8-slot chassis with over 50 measurement-specific NI C Series I/O modules and can operate stand-alone with a built-in controller or connect to a host computer over USB, Ethernet, or Wi-Fi. Sensor Measurement Device Software Signal Conditioning Analog-to-Digital Converter Driver Software Application Software 28

29 NI Is the Global Leader in Data Acquisition With more than 20 years of DAQ hardware history and millions of channels sold PCI M Series X Series, WSN NuBus PXI PXI Express, NI CompactDAQ 1-Slot NI CompactDAQ ISA R Series NI Wi-Fi DAQ Ethernet DAQ NI CompactDAQ Stand-Alone Chassis E Series USB DAQ, PCI Express USB X Series SC Express 29

30 NI Data Acquisition Hardware Families PXI Optimized for high channel counts and tight synchronization System NI CompactDAQ Customize with a variety of chassis and module types Desktop DAQ Install in a desktop PC slot for maximum data throughput Single Device Portable DAQ Easily connect to any laptop or desktop with simple setup 30

31 Traditional Hardware Components Mixed-Measurement Systems Usually Involve Additional Connectivity and Conditioning Sensors/Signals Physical Connectivity Signal Conditioning ADC Thermocouple Screw Term TC Jack Amplification, Cold-Junction Compensation, Filtering Accelerometer BNC SMB Excitation, Anti-Alias Filtering, Dynamic Range Strain Gage Screw Term 10P10C (RJ50) Voltage Excitation, Bridge Configuration, Linearization, Filtering Solar Cell Screw Term Banana Isolation (etc) 31

32 C Series I/O Modules Over 100 NI and Partner Modules Analog Input Analog Output Digital I/O Relay Output Counter, Pulse Generation Communication CAN LIN PROFIBUS Motion Control Wireless Engine Control Signal Conditioning Rugged Mechanicals Signal Conditioning/Filtering Isolation Barrier 32

33 Data Acquisition : Hardware & Software Integration

34 Why is Software Important? Total Measurement Application Cost = Price of HW + Price of SW + Cost of Development 36%, Price of HW & SW Visible Price 64%, Development Time Costs Hidden Costs Source: National Instruments Survey of Data Acquisition Customers and Prospects

35 DAQ Software Options Test and Data Management Software NI TestStand, DIAdem Interactive Tools LabVIEW SignalExpress Interactive development Application Development Software LabVIEW Graphical Development LabWindows/ CVI ANSI C Development Measurement Studio Visual Studio Components Measurement and Control Services: NI-DAQmx or NI-DAQmx Base Data Acquisition Hardware 35

36 Measurement & Automation Explorer (MAX) Task and channel creation Built-in test panel windows Device configuration and connection management Signal connection diagrams 36

37 The LabVIEW Environment Front Panel User Interface Block Diagram Program Logic 40

38 LabVIEW Data Acquisition Demo 41

39 Spider Dredging System Level Seabed for Oil and Gas Exploration Application: Controlling hydraulic systems on the Nexans Spider remote operated vehicle (ROV) as it levels the seabed and clears a path for the pipeline. The LabVIEW platform has helped Nexans develop a system that is easy to maintain due to the consistent programming paradigm for both HMI and embedded control, even in extreme conditions. 42

40 Questions? 43

ni.com Sensor Measurement Fundamentals Series

ni.com Sensor Measurement Fundamentals Series Sensor Measurement Fundamentals Series Introduction to Data Acquisition Basics and Terminology Litkei Márton District Sales Manager National Instruments What Is Data Acquisition (DAQ)? 3 Why Measure? Engineers

More information

Introduction to NI LabVIEW and Computer-Based Measurements. Elias Nicolas Applications Engineer National Instruments

Introduction to NI LabVIEW and Computer-Based Measurements. Elias Nicolas Applications Engineer National Instruments Introduction to NI LabVIEW and Computer-Based Measurements Elias Nicolas Applications Engineer National Instruments Today, We ll Explore: The Challenges of Making Measurements Introduction to LabVIEW Fundamentals

More information

Developer Techniques Sessions

Developer Techniques Sessions 1 Developer Techniques Sessions Physical Measurements and Signal Processing Control Systems Logging and Networking 2 Abstract This session covers the technologies and configuration of a physical measurement

More information

Signal Conditioning Fundamentals for PC-Based Data Acquisition Systems

Signal Conditioning Fundamentals for PC-Based Data Acquisition Systems Application Note 048 Signal Conditioning Fundamentals for PC-Based Data Acquisition Systems Introduction PC-based data acquisition (DAQ) systems and plugin boards are used in a very wide range of applications

More information

ELG3336 Design of Mechatronics System

ELG3336 Design of Mechatronics System ELG3336 Design of Mechatronics System Elements of a Data Acquisition System 2 Analog Signal Data Acquisition Hardware Your Signal Data Acquisition DAQ Device System Computer Cable Terminal Block Data Acquisition

More information

MECE 3320 Measurements & Instrumentation. Data Acquisition

MECE 3320 Measurements & Instrumentation. Data Acquisition MECE 3320 Measurements & Instrumentation Data Acquisition Dr. Isaac Choutapalli Department of Mechanical Engineering University of Texas Pan American Sampling Concepts 1 f s t Sampling Rate f s 2 f m or

More information

RF and Microwave Test and Design Roadshow Cape Town & Midrand

RF and Microwave Test and Design Roadshow Cape Town & Midrand RF and Microwave Test and Design Roadshow Cape Town & Midrand Advanced PXI Technologies Signal Recording, FPGA s, and Synchronization Philip Ehlers Outline Introduction to the PXI Architecture PXI Data

More information

National Instruments Accelerating Innovation and Discovery

National Instruments Accelerating Innovation and Discovery National Instruments Accelerating Innovation and Discovery There s a way to do it better. Find it. Thomas Edison Engineers and scientists have the power to help meet the biggest challenges our planet faces

More information

Lab 2A: Introduction to Sensing and Data Acquisition

Lab 2A: Introduction to Sensing and Data Acquisition Lab 2A: Introduction to Sensing and Data Acquisition Prof. R.G. Longoria Department of Mechanical Engineering The University of Texas at Austin June 12, 2014 1 Lab 2A 2 Sensors 3 DAQ 4 Experimentation

More information

Lab 12 Laboratory 12 Data Acquisition Required Special Equipment: 12.1 Objectives 12.2 Introduction 12.3 A/D basics

Lab 12 Laboratory 12 Data Acquisition Required Special Equipment: 12.1 Objectives 12.2 Introduction 12.3 A/D basics Laboratory 12 Data Acquisition Required Special Equipment: Computer with LabView Software National Instruments USB 6009 Data Acquisition Card 12.1 Objectives This lab demonstrates the basic principals

More information

ni.com Sensor Measurement Fundamentals Series

ni.com Sensor Measurement Fundamentals Series Sensor Measurement Fundamentals Series How to Design an Accurate Temperature Measurement System Jackie Byrne Product Marketing Engineer National Instruments Sensor Measurements 101 Sensor Signal Conditioning

More information

EKT 314/4 LABORATORIES SHEET

EKT 314/4 LABORATORIES SHEET EKT 314/4 LABORATORIES SHEET WEEK DAY HOUR 4 1 2 PREPARED BY: EN. MUHAMAD ASMI BIN ROMLI EN. MOHD FISOL BIN OSMAN JULY 2009 Creating a Typical Measurement Application 5 This chapter introduces you to common

More information

USB Dynamic Signal Acquisition

USB Dynamic Signal Acquisition NI USB-9233 24-bit resolution 102 db dynamic range 50 ks/s max rate per channel 4 simultaneous analog inputs ±5 V input range AC coupled with IEPE power Hi-Speed USB 2.0 Recommended Software LabVIEW LabVIEW

More information

ARCHIVES: Benchmarking Single-Point Performance on National Instruments Real-Time Hardware

ARCHIVES: Benchmarking Single-Point Performance on National Instruments Real-Time Hardware ARCHIVES: Benchmarking Single-Point Performance on National Instruments Real-Time This document is the archives for past benchmarking data found either in error or in using new and different targets. You

More information

Correlation of Voltage and Temperature Measurement

Correlation of Voltage and Temperature Measurement MEASURpoint Correlation of Voltage and Temperature Measurement Precision Measurement Instrument MEASURpoint is an ultra-accurate instrument for any combination of temperature and voltage to be measured

More information

24-Bit, ks/s Dynamic Signal Acquisition and Generation

24-Bit, ks/s Dynamic Signal Acquisition and Generation NI 4461, NI 4462 2 or 4 simultaneously sampled analog inputs 2 simultaneously updated analog outputs (NI 4461 only) 118 db dynamic range, 24-bit resolution 204.8 ks/s maximum sampling rate 92 khz alias-free

More information

ni.com Sensor Measurement Fundamentals Series

ni.com Sensor Measurement Fundamentals Series Sensor Measurement Fundamentals Series Strain Gage Measurements Doug Farrell Product Manager National Instruments Key Takeaways Strain gage fundamentals Bridge-based measurement fundamentals Measurement

More information

2.5 GHz 75 Ω Multiplexer and SPDT Relay Switches

2.5 GHz 75 Ω Multiplexer and SPDT Relay Switches 2.5 GHz Multiplexer and SPDT Relay Switches NI PXI-255x NEW! 2.5 GHz bandwidth characteristic impedance 30 V max switching voltage 0.5 A max switching current 10 W max switching power Mini SMB direct connectivity

More information

Data acquisition and instrumentation. Data acquisition

Data acquisition and instrumentation. Data acquisition Data acquisition and instrumentation START Lecture Sam Sadeghi Data acquisition 1 Humanistic Intelligence Body as a transducer,, data acquisition and signal processing machine Analysis of physiological

More information

Essential Technologies for Energy Efficiency and Management

Essential Technologies for Energy Efficiency and Management Essential Technologies for Energy Efficiency and Management Christoph Wimmer christoph.wimmer@ni.com 425-301-6153 30 Years of Engineering Trends, Challenges, and Milestones 1980 1990 2000 2010 Why more

More information

FYS3240 PC-based instrumentation and microcontrollers. Signal sampling. Spring 2015 Lecture #5

FYS3240 PC-based instrumentation and microcontrollers. Signal sampling. Spring 2015 Lecture #5 FYS3240 PC-based instrumentation and microcontrollers Signal sampling Spring 2015 Lecture #5 Bekkeng, 29.1.2015 Content Aliasing Nyquist (Sampling) ADC Filtering Oversampling Triggering Analog Signal Information

More information

National Instruments Switches

National Instruments Switches ni.com National Instruments Switches Raviteja Chivukula Webinar Overview A. Switch Basics A. Recap B. Advanced Switch Topics A. High Channel Switches B. Fault Insertion Units C. Resistor Modules D. RF

More information

Stephen Plumb National Instruments

Stephen Plumb National Instruments RF and Microwave Test and Design Roadshow Cape Town and Midrand October 2014 Stephen Plumb National Instruments Our Mission We equip engineers and scientists with tools that accelerate productivity, innovation,

More information

National Instruments Flex II ADC Technology The Flexible Resolution Technology inside the NI PXI-5922 Digitizer

National Instruments Flex II ADC Technology The Flexible Resolution Technology inside the NI PXI-5922 Digitizer National Instruments Flex II ADC Technology The Flexible Resolution Technology inside the NI PXI-5922 Digitizer Kaustubh Wagle and Niels Knudsen National Instruments, Austin, TX Abstract Single-bit delta-sigma

More information

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise!

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise! SIRIUS Overview NEW dual ADC SIRIUS Overview Let`s get SIRIUS! The new hardware generation makes your measurement more precise! Dual core Input SIRIUS from Dewesoft This new technology solves the often

More information

Things to consider while selecting a Digitizer

Things to consider while selecting a Digitizer Things to consider while selecting a Digitizer Chinmay Anand Misra Certified LabVIEW Developer Staff Applications Engineer Things to Consider Specifications Ecosystem Agenda Top 10 things to consider while

More information

CHAPTER 7 HARDWARE IMPLEMENTATION

CHAPTER 7 HARDWARE IMPLEMENTATION 168 CHAPTER 7 HARDWARE IMPLEMENTATION 7.1 OVERVIEW In the previous chapters discussed about the design and simulation of Discrete controller for ZVS Buck, Interleaved Boost, Buck-Boost, Double Frequency

More information

EKT 314/4 LABORATORIES SHEET

EKT 314/4 LABORATORIES SHEET EKT 314/4 LABORATORIES SHEET WEEK DAY HOUR 4 2 1 PREPARED BY: EN. MUHAMAD ASMI BIN ROMLI EN. MOHD FISOL BIN OSMAN JULY 2009 Measuring Strain 10 This chapter describes how to measure strain using DAQ devices

More information

NI Circuits Teaching Solution

NI Circuits Teaching Solution NI Circuits Teaching Solution Khaled Moselhy Field Application Engineer National Instruments Egypt Trends in Engineering Education Integrate theory with more hands-on experiences Collaborative, project-based

More information

Online Monitoring System for Generators in Nuclear Power Plants

Online Monitoring System for Generators in Nuclear Power Plants Online Monitoring for Generators in Nuclear Power Plants Dipl. Ing. Otto Gansner PI Electronics AG 5405 Baden-Dättwil +41 56 4868065 otto.gansner@pie.ch Contents PI Electronics AG PI Electronics AG Baden-Dättwil,

More information

4 Things to Consider When Using a DAQ as a Data Logger

4 Things to Consider When Using a DAQ as a Data Logger 4 Things to Consider When Using a DAQ as a Data Logger Introduction There is a growing trend across all industries to design feature-rich products. The more features added to a product, the more complex

More information

Data Acquisition and Signal Conditioning

Data Acquisition and Signal Conditioning Data Acquisition and Signal Conditioning Course Manual Course Software Version 7.0 August 2003 Edition Part Number 320733K-01 Data Acquisition and Signal Conditioning Copyright 1995 2003 National Instruments

More information

Fallstricke präziser DC- Messungen

Fallstricke präziser DC- Messungen Fallstricke präziser DC- Messungen Sascha Egger, Applications Engineer Group Leader National Instruments Switzerland GmbH Agenda Overview of Precision Test Systems Techniques for: Low-voltage measurements

More information

SCXI 8-Channel Isolated Analog Input Modules

SCXI 8-Channel Isolated Analog Input Modules SCXI 8-Channel Isolated Analog Input NI, NI SCXI-1120, NI SCXI-1120D 8 channels 333 ks/s maximum sampling rate Gain and lowpass filter settings per channel Up to 300 V rms working isolation per channel

More information

FYS3240 PC-based instrumentation and microcontrollers. Signal sampling. Spring 2017 Lecture #5

FYS3240 PC-based instrumentation and microcontrollers. Signal sampling. Spring 2017 Lecture #5 FYS3240 PC-based instrumentation and microcontrollers Signal sampling Spring 2017 Lecture #5 Bekkeng, 30.01.2017 Content Aliasing Sampling Analog to Digital Conversion (ADC) Filtering Oversampling Triggering

More information

Data Acquisition Boards and USB-DAQ

Data Acquisition Boards and USB-DAQ Data Acquisition Boards and USB-DAQ CHRISTIAN ANTFOLK Announcement Choose a project Project description deadline 26.11.2017 (you can start working on the project before that) Lab 2 will be Wednesday den

More information

EDS-400A COMPACT RECORDER. New KYOWA ELECTRONIC INSTRUMENTS CO., LTD.

EDS-400A COMPACT RECORDER. New KYOWA ELECTRONIC INSTRUMENTS CO., LTD. KYOWA ELECTRONIC INSTRUMENTS CO., LTD. COMPACT RECORDER EDS-400A Compact Dynamic Strain Recorder Entering the scene in advanced measurement of strain, vibration, pressure, load, etc. New www.kyowa-ei.co.jp

More information

FTMS Booster X1 High-performance data acquisition system for FT-ICR MS

FTMS Booster X1 High-performance data acquisition system for FT-ICR MS FTMS Booster X1 High-performance data acquisition system for FT-ICR MS What is FTMS Booster? The Spectroswiss FTMS Booster X1 is a high-performance data acquisition and analysis system based on state-of-the-art

More information

Measurement, Sensors, and Data Acquisition in the Two-Can System

Measurement, Sensors, and Data Acquisition in the Two-Can System Measurement, Sensors, and Data Acquisition in the Two-Can System Prof. R.G. Longoria Updated Fall 2010 Goal of this week s lab Gain familiarity with using sensors Gain familiarity with using DAQ hardware

More information

PC-based controller for Mechatronics System

PC-based controller for Mechatronics System Course Code: MDP 454, Course Name:, Second Semester 2014 PC-based controller for Mechatronics System Mechanical System PC Controller Controller in the Mechatronics System Configuration Actuators Power

More information

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise!

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise! Overview NEW dual ADC Overview Let`s get! The new hardware generation makes your measurement more precise! Dual core Input from Dewesoft This new technology solves the often faced problem that the signal

More information

1510A PRECISION SIGNAL SIMULATOR

1510A PRECISION SIGNAL SIMULATOR A worldwide leader in precision measurement solutions Portable signal source for calibrating electronic equipment and machinery monitoring systems. 1510A PRECISION SIGNAL SIMULATOR Voltage Signals Charge

More information

Full system level calibration (levels, s-parameters, noise) Full RF source and measure capability Applications Vector network analyzer capability

Full system level calibration (levels, s-parameters, noise) Full RF source and measure capability Applications Vector network analyzer capability Semiconductor Test AXRF - Multi-Port PXI RF Subsystem Modulated Vector Source and Measurement Data Sheet The most important thing we build is trust Functionality High speed, reliable solid state design

More information

SNAP Quadrature Input Module

SNAP Quadrature Input Module SNAP Quadrature Input Module Features 4,000 Vrms optical isolation Built-in LED status indicators 4 times encoder resolution Input signals in 4 24 VDC range Description The SNAP-IDC5Q quadrature input

More information

AS-1250FE Datasheet Dynamic Signal Acquisition Front-End for Rotating Machinery Monitoring and Analysis

AS-1250FE Datasheet Dynamic Signal Acquisition Front-End for Rotating Machinery Monitoring and Analysis Dynamic Signal Acquisition Front-End for Rotating Machinery Monitoring and Analysis HIGH PERFORMANCE ACQUISITION The AS-1250FE is a high performance, compact and flexible data acquisition hardware platform

More information

PC-supported measurement

PC-supported measurement PC-supported measurement Complete measurement data acquisition system Expert Key devices acquire and monitor measurement data and automate experiment and test stand installations. The devices are supplied

More information

Analog front-end electronics

Analog front-end electronics FYS3240 PC-based instrumentation and microcontrollers Analog front-end electronics Spring 2017 Lecture #6 Bekkeng, 30.1.2017 Considerations for analog signals Signal source - grounded or floating Source

More information

Modular Smart Interfaces

Modular Smart Interfaces Modular Smart Interfaces Automotive Energy & Power Analysis Aerospace & Defense Transportation General Test & Measurement Modular Smart Interfaces MSI Series Modular Smart Interfaces (MSI) bring an expanded

More information

for NI PXI/PXIe User Manual Revision March PVI Systems, Inc. All Rights Reserved.

for NI PXI/PXIe User Manual Revision March PVI Systems, Inc. All Rights Reserved. for NI PXI/PXIe User Manual Revision 1.0.3 March 2014 2011-2013 PVI Systems, Inc. All Rights Reserved. Table of Contents 1.1 Software Requirements... 4 1.2 Hardware Requirements... 4 1.3 Support... 4 2

More information

RF and Microwave Test and Design Roadshow 5 Locations across Australia and New Zealand

RF and Microwave Test and Design Roadshow 5 Locations across Australia and New Zealand RF and Microwave Test and Design Roadshow 5 Locations across Australia and New Zealand Advanced PXI Technologies Signal Recording, FPGA s, and Synchronization Outline Introduction to the PXI Architecture

More information

Chapter 7. Introduction. Analog Signal and Discrete Time Series. Sampling, Digital Devices, and Data Acquisition

Chapter 7. Introduction. Analog Signal and Discrete Time Series. Sampling, Digital Devices, and Data Acquisition Chapter 7 Sampling, Digital Devices, and Data Acquisition Material from Theory and Design for Mechanical Measurements; Figliola, Third Edition Introduction Integrating analog electrical transducers with

More information

SPIDER-80SG. General Data Acquisition Device with Strain Gage Measurement. Spider Measurement Solution

SPIDER-80SG. General Data Acquisition Device with Strain Gage Measurement. Spider Measurement Solution SPIDER-80SG General Data Acquisition Device with Strain Gage Measurement Spider Measurement Solution W W W. C R Y S TA L I N S T R U M E N T S. C O M Introducing the Spider-80SG Spider-80SG Modular Strain

More information

PXI Timing and Synchronization Control

PXI Timing and Synchronization Control NI PXI-665x Works with all PXI modules Multichassis PXI synchronization Onboard routing of internal or external clock and trigger signals PXI slot 2 star trigger controller Onboard high-stability references

More information

High Stability Voltage Source

High Stability Voltage Source Bilt System module - BE2100 High Stability Voltage Source Voltage to ±12V, current to ±200mA High Resolution: 21 bits, 6 ½ digits Ultra Low Noise: down to 6µVp-p Clean output noise spectrum with no spike

More information

23270: AUGMENTED REALITY FOR NAVIGATION AND INFORMATIONAL ADAS. Sergii Bykov Technical Lead Machine Learning 12 Oct 2017

23270: AUGMENTED REALITY FOR NAVIGATION AND INFORMATIONAL ADAS. Sergii Bykov Technical Lead Machine Learning 12 Oct 2017 23270: AUGMENTED REALITY FOR NAVIGATION AND INFORMATIONAL ADAS Sergii Bykov Technical Lead Machine Learning 12 Oct 2017 Product Vision Company Introduction Apostera GmbH with headquarter in Munich, was

More information

Series GLET Accessory for dataloggers series GL in modular enclosure

Series GLET Accessory for dataloggers series GL in modular enclosure PRESSURE LOAD TORQUE POSITION ROTARY ANGLE TILT ACCELERATION VIBRATION RATE SIGNAL CONDITIONER DATALOGGER Series GLET Accessory for dataloggers series GL in modular enclosure Models: GLET-IU-BNC-BA4 passive,

More information

Measurement Studio NI-DAQmx.NET Examples

Measurement Studio NI-DAQmx.NET Examples Page 1 of 13 NI Measurement Studio.NET Class Library Measurement Studio NI-DAQmx.NET Examples When you install the Measurement Studio NI-DAQmx.NET class library, example programs are installed by default.

More information

EMX-1434 APPLICATIONS FEATURES A SMART PXI EXPRESS 4-CHANNEL KSA/S ARBITRARY WAVEFORM GENERATOR

EMX-1434 APPLICATIONS FEATURES A SMART PXI EXPRESS 4-CHANNEL KSA/S ARBITRARY WAVEFORM GENERATOR 83-0061-000 15A D A T A S H E E T EMX-1434 SMART PXI EXPRESS 4-CHANNEL 204.8 KSA/S ARBITRARY WAVEFORM GENERATOR APPLICATIONS Modal / GVT (Ground Vehicle Testing) Acoustics Shock / Vibration Rotational

More information

August 5 8, 2013 Austin, Texas. Preliminary Conference Program. Register now at ni.com/niweek or call

August 5 8, 2013 Austin, Texas. Preliminary Conference Program. Register now at ni.com/niweek or call August 5 8, 2013 Austin, Texas Preliminary Conference Program Register now at ni.com/niweek or call 888 564 9335 NIWeek 2013 Schedule Training and Certification Exams NI Alliance Day Academic Forum Build

More information

Save Money and Decrease Downtime with Vehicle and Equipment Monitoring. Embedded Technology Summit National Instruments

Save Money and Decrease Downtime with Vehicle and Equipment Monitoring. Embedded Technology Summit National Instruments Save Money and Decrease Downtime with Vehicle and Equipment Monitoring Embedded Technology Summit National Instruments Costa Allegra Types of Vehicle Monitoring Propulsion Task Based Collateral Damage

More information

Chapter 2 Analog-to-Digital Conversion...

Chapter 2 Analog-to-Digital Conversion... Chapter... 5 This chapter examines general considerations for analog-to-digital converter (ADC) measurements. Discussed are the four basic ADC types, providing a general description of each while comparing

More information

Contents. CALIBRATION PROCEDURE NI PXIe-4463 DSA Analog Output

Contents. CALIBRATION PROCEDURE NI PXIe-4463 DSA Analog Output CALIBRATION PROCEDURE NI PXIe-4463 DSA Analog Output This document contains the verification and adjustment procedures for the National Instruments PXIe-4463 with either BNC or mini-xlr connectors. For

More information

EMX-4350 APPLICATIONS FEATURES A SMART PXI EXPRESS 625 KSA/S 4-CHANNEL DIGITIZER

EMX-4350 APPLICATIONS FEATURES A SMART PXI EXPRESS 625 KSA/S 4-CHANNEL DIGITIZER 83-0018-000 14A D A T A S H E E T EMX-4350 SMART PXI EXPRESS 625 KSA/S 4-CHANNEL DIGITIZER APPLICATIONS Dynamic Signal Analysis High Speed Data Acquisition Modal Analysis Ground Vehicle Testing (GVT) Acoustic

More information

Development of 4/16-Channel Data Acquisition System Using Lab VIEW

Development of 4/16-Channel Data Acquisition System Using Lab VIEW Development of 4/16-Channel Data Acquisition System Using Lab VIEW Kishori Jadhav 1, Nisha Sarwade 2 1 PG scholar, Electrical department, VJTI, Matunga, 400019 2 Associate professor, Electrical department,

More information

FAST Fourier Transform (FFT) and Digital Filtering Using LabVIEW

FAST Fourier Transform (FFT) and Digital Filtering Using LabVIEW FAST Fourier Transform (FFT) and Digital Filtering Using LabVIEW Instructor s Portion Wei Lin Department of Biomedical Engineering Stony Brook University Summary Uses This experiment requires the student

More information

Training Schedule. Robotic System Design using Arduino Platform

Training Schedule. Robotic System Design using Arduino Platform Training Schedule Robotic System Design using Arduino Platform Session - 1 Embedded System Design Basics : Scope : To introduce Embedded Systems hardware design fundamentals to students. Processor Selection

More information

User Guide for TPCX, TPCE, TPCE-LE and TPCE-I

User Guide for TPCX, TPCE, TPCE-LE and TPCE-I User Guide for TPCX, TPCE, TPCE-LE and TPCE-I 2016 Elsys AG 1 Content 1. Quick Installation 4 2. SYSTEM REQUIREMENTS 5 2.1 TPCX PCI Boards 5 2.2 TPCE PCIe Boards 5 3. Hardware 6 3.1 Signal Inputs, Connector

More information

Thermocouple Measurement Using AI-225/AI-207 App Note # United Electronic Industries, Inc. All Rights Reserved.

Thermocouple Measurement Using AI-225/AI-207 App Note # United Electronic Industries, Inc. All Rights Reserved. Thermocouple Measurement Using AI-225/AI-207 App Note #021 A thermocouple is a sensor used to measure temperature in a wide range A of applications. Its ability to sense temperature is based on the so-called

More information

Portable Multi-Channel Recorder Model DAS240-BAT

Portable Multi-Channel Recorder Model DAS240-BAT Data Sheet Portable Multi-Channel Recorder The DAS240-BAT measures parameters commonly found in process applications including voltage, temperature, current, resistance, frequency and pulse. It includes

More information

Determining the Fatigue Life of Aero-Engine Blades

Determining the Fatigue Life of Aero-Engine Blades w w w. s c i t e k c o n s u l t a n t s. c o. u k Determining the Fatigue Life of Aero-Engine Blades SCITEK Consultants Ltd Martin Haste, Florian Faurillou, Jon Bates, Marios S Christodoulou 4 th November

More information

Design Implementation Description for the Digital Frequency Oscillator

Design Implementation Description for the Digital Frequency Oscillator Appendix A Design Implementation Description for the Frequency Oscillator A.1 Input Front End The input data front end accepts either analog single ended or differential inputs (figure A-1). The input

More information

RF and Microwave Test and Design Roadshow 5 Locations across Australia and New Zealand

RF and Microwave Test and Design Roadshow 5 Locations across Australia and New Zealand RF and Microwave Test and Design Roadshow 5 Locations across Australia and New Zealand Advanced VNA Measurements Agenda Overview of the PXIe-5632 Architecture SW Experience Overview of VNA Calibration

More information

RX1032 PRECISION TEMPERATURE MEASUREMENTS FOR RUGGED ENVIRONMENTS FEATURES. 32-Channel Thermocouple Measurement System

RX1032 PRECISION TEMPERATURE MEASUREMENTS FOR RUGGED ENVIRONMENTS  FEATURES. 32-Channel Thermocouple Measurement System WWW.VTIINSTRUMENTS.COM RX1032 PRECISION TEMPERATURE MEASUREMENTS FOR RUGGED ENVIRONMENTS FEATURES 32-Channel Thermocouple Measurement System Advanced CJC Implementation 1000 Sample/sec/channel Scan Rate

More information

FD 5 / 10 / 15. Fast acquisition module with universal synchronized inputs and embedded webserver software

FD 5 / 10 / 15. Fast acquisition module with universal synchronized inputs and embedded webserver software Fast acquisition module with universal synchronized inputs and embedded webserver software FD systems are a series of fast (470 Hz/channel) and flexible data acquisition modules available in 3 models of

More information

VCSO Mechanical Shock Compensation

VCSO Mechanical Shock Compensation VCSO Mechanical Shock Compensation Who are we? Team members: Max Madore Joseph Hiltz-Maher Shaun Hew Shalin Shah Advisor: Helena Silva Phonon contact: Scott Kraft Project Overview VCSO and mechanical vibration

More information

DT9838. Strain- and Bridge-Based Measurement Module. Key Features: Bridge Configurations. Analog Input Features

DT9838. Strain- and Bridge-Based Measurement Module. Key Features: Bridge Configurations. Analog Input Features Strain- and Bridge-Based Measurement Module The module is a strain gage measurement device intended for full-, half, and quarter-bridge strain gage elements and bridge-based sensor assemblies such as load

More information

FRONTDAQ 20. High speed acquisition module with universal synchronized inputs and embedded webserver software

FRONTDAQ 20. High speed acquisition module with universal synchronized inputs and embedded webserver software FRONTDAQ 20 High speed acquisition module with universal synchronized inputs and embedded webserver software FrontDaq system is a high speed acquisition module (7680 Hz/channel) with 20 analogue synchronized

More information

Integrating a PXI Automated Test System

Integrating a PXI Automated Test System Integrating a PXI Automated Test System Top Considerations to Integrating a PXI Automated Test System Agilent Technologies Software and Modular Solutions Alan Lesko Application Engineer April 24 th, 2012

More information

LV-Link 3.0 Software Interface for LabVIEW

LV-Link 3.0 Software Interface for LabVIEW LV-Link 3.0 Software Interface for LabVIEW LV-Link Software Interface for LabVIEW LV-Link is a library of VIs (Virtual Instruments) that enable LabVIEW programmers to access the data acquisition features

More information

NEW! AOIP FD5 Advanced Digital Data Logger

NEW! AOIP FD5 Advanced Digital Data Logger NEW! AOIP FD5 Advanced Digital Data Logger Versatile data logger, each output channel can be custom configured for current, voltage, resistance, frequency, and temperature. The NEW! FD5 Digital Datalogger

More information

WebSeminar: Signal Chain Overview

WebSeminar: Signal Chain Overview WebSeminar: December, 2005 Hello, and welcome to the Microchip Technology Web Seminar overview of signal chains. My name is Kevin Tretter and I am a Product Marketing Engineer within Microchip Technology

More information

CALIBRATION PROCEDURE PXIe-4302/4303 and TB-4302C 32 Ch, 24-bit, 5 ks/s or 51.2 ks/s Simultaneous Filtered Data Acquisition Module. ni.

CALIBRATION PROCEDURE PXIe-4302/4303 and TB-4302C 32 Ch, 24-bit, 5 ks/s or 51.2 ks/s Simultaneous Filtered Data Acquisition Module. ni. CALIBRATION PROCEDURE PXIe-4302/4303 and TB-4302C 32 Ch, 24-bit, 5 ks/s or 51.2 ks/s Simultaneous Filtered Data Acquisition Module Français Deutsch ni.com/manuals This document contains the verification

More information

Specifications Test Conditions Vs = ± 15 V, Ta = 25 C Gain Gain Values 40, 60, 80, 100 db indicated by four LEDs Gain Accuracy ± 0.1 % (between settin

Specifications Test Conditions Vs = ± 15 V, Ta = 25 C Gain Gain Values 40, 60, 80, 100 db indicated by four LEDs Gain Accuracy ± 0.1 % (between settin Electro Optical Components, Inc. SUNSTAR 传感与控制 http://www.sensor-ic.com/ 5460 Skylane Boulevard, Santa Rosa, CA 95403 Toll Free: 855-EOC-6300 www.eoc-inc.com info@eoc-inc.com Features Variable Gain 40

More information

IVI STEP TYPES. Contents

IVI STEP TYPES. Contents IVI STEP TYPES Contents This document describes the set of IVI step types that TestStand provides. First, the document discusses how to use the IVI step types and how to edit IVI steps. Next, the document

More information

EX FEATURES. Stand-alone 48-channel unit with built-in Ethernet controller. Built-in bridge completion and Excitation

EX FEATURES. Stand-alone 48-channel unit with built-in Ethernet controller. Built-in bridge completion and Excitation data sheet EX1629-001 High-performance Remote Strain Gage Measurement Unit FEATURES Stand-alone 48-channel unit with built-in Ethernet controller Built-in bridge completion and Excitation 24-bit A/D per

More information

Data Acquisition (DAQ) Fundamentals

Data Acquisition (DAQ) Fundamentals Flow Measurements Manometers Transducers Pitot tubes Thermocouples Hot wire systems a. Anemometers b. Probes - Simple - Slented - Cross-wire LDA (Laser Doppler Anemometry) PIV (Particle Image Velocimetry)

More information

A SMART METHOD FOR AUTOMATIC TEMPERATURE CONTROL

A SMART METHOD FOR AUTOMATIC TEMPERATURE CONTROL ABSTRACT A SMART METHOD FOR AUTOMATIC TEMPERATURE CONTROL Pratima Datta 1, Pritha Saha 2, Bapita Roy 3 1,2 Department of Applied Electronics and Instrumentation, Guru Nanak Institute of Technology, (India)

More information

CHEMICAL ENGINEERING 2I03

CHEMICAL ENGINEERING 2I03 Student Name: Student ID: CHEMICAL ENGINEERING 2I03 DAY CLASS Duration 2 hours McMaster University Practice Exam Dr. M. Thompson The final test includes 60 questions on 12 pages. This test paper must be

More information

Ethernet-Based Temperature, Voltage and Strain Measurement Modules

Ethernet-Based Temperature, Voltage and Strain Measurement Modules Ethernet-Based Temperature, Voltage and Strain Measurement Modules OMB-NET6000 Series OMB-NET6220 shown smaller than actual size. U 12 Analog Inputs U 8 Digital I/O U Simultaneous Sampling U Multiple Trigger

More information

Part Numbers. SNAP-AIARMS-i SNAP-AIARMS-i-FM* SNAP-AIVRMS-i SNAP-AIVRMS-i-FM* SNAP-AIMA-i. SNAP-AIMA-iSRC SNAP-AIMA-iSRC-FM* SNAP-AIMA2-i

Part Numbers. SNAP-AIARMS-i SNAP-AIARMS-i-FM* SNAP-AIVRMS-i SNAP-AIVRMS-i-FM* SNAP-AIMA-i. SNAP-AIMA-iSRC SNAP-AIMA-iSRC-FM* SNAP-AIMA2-i SNAP Isolated Analog Input Modules Features Channel-to-channel isolation Rugged packaging and convenient pluggable wiring. Accepts wire. Factory calibrated; no user adjustment necessary Out-of-range indication

More information

GFT bit High Speed Digitizer

GFT bit High Speed Digitizer FEATURES Up to 4 analog channels in only 1U space Up to 2GS/s sampling rate per channel 14 bits vertical resolution DC coupled with up to 1GHz bandwidth Programmable DC offset Internal and external clock

More information

Telemetrie-Messtechnik Schnorrenberg

Telemetrie-Messtechnik Schnorrenberg Telemetrie-Messtechnik Schnorrenberg CT16-Wheel User manual TMS Telemetrie-Messtechnik Schnorrenberg Dipl.-Ing. Werner Schnorrenberg Habichtweg 30, D-51429 Bergisch Gladbach, Tel: 02204-9815-52, Fax: 02204-9815-53,

More information

SIGMA-DELTA CONVERTER

SIGMA-DELTA CONVERTER SIGMA-DELTA CONVERTER (1995: Pacífico R. Concetti Western A. Geophysical-Argentina) The Sigma-Delta A/D Converter is not new in electronic engineering since it has been previously used as part of many

More information

Control and Signal Processing in a Structural Laboratory

Control and Signal Processing in a Structural Laboratory Control and Signal Processing in a Structural Laboratory Authors: Weining Feng, University of Houston-Downtown, Houston, Houston, TX 7700 FengW@uhd.edu Alberto Gomez-Rivas, University of Houston-Downtown,

More information

Electronic Instrumentation and Measurements

Electronic Instrumentation and Measurements Electronic Instrumentation and Measurements A fundamental part of many electromechanical systems is a measurement system that composed of four basic parts: Sensors Signal Conditioning Analog-to-Digital-Conversion

More information

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT, 250KSPS ADC

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT, 250KSPS ADC DESCRIPTION QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 1255 LTC1605CG/LTC1606CG The LTC1606 is a 250Ksps ADC that draws only 75mW from a single +5V Supply, while the LTC1605 is a 100Ksps ADC that draws

More information

Machine Data Acquisition. Powerful vibration data collectors, controllers, sensors, and field analyzers

Machine Data Acquisition. Powerful vibration data collectors, controllers, sensors, and field analyzers Machine Data Acquisition Powerful vibration data collectors, controllers, sensors, and field analyzers CHOOSE THE PERFECT HARDWARE DESIGN SUITED FOR YOU BRAUN, BRAINS AND BEAUTY TOTAL TRIO IS A COMPLETE

More information

A Rapid Graphical Programming Approach to SDR Design and Prototyping with LabVIEW and the USRP

A Rapid Graphical Programming Approach to SDR Design and Prototyping with LabVIEW and the USRP A Rapid Graphical Programming Approach to SDR Design and Prototyping with LabVIEW and the USRP Filip Langenaken Academic Program Manager Benelux & Nordic National Instruments NI-USRP: a Platform for SDR

More information

Design IV. E232 Spring 07

Design IV. E232 Spring 07 Design IV Spring 07 Class 8 Bruce McNair bmcnair@stevens.edu 8-1/38 Computerized Data Acquisition Measurement system architecture System under test sensor sensor sensor sensor signal conditioning signal

More information

Data Acquisition System

Data Acquisition System Data Acquisition System OMNIACERA2300 RA2300 Simple Pen-recorder Mode Visualized amp.setting-display & touch panel provide simple operation like Pen-Recorder. Dynamic wave form in Wide Display 12.1 inches

More information