optional View the installation video for FGVL on Belimo's YouTube channel: 1https://youtu.be/fqs8XfRPyQw 32 mm 19 mm 20 Nm
|
|
- Caroline Bryan
- 6 years ago
- Views:
Transcription
1 B QUICK MOUNT VISUL INSTRUCTION MNUL FGVL Linkage with EV Series ctuators b STYLE mm optional /4 - UNF /4-3 UNEF 3 3/ - 4 UNF 05/6 - Subject to change. Belimo ircontrols (US), Inc. Optional /6-0 UNF / - 0 UNF M x.5 M x M0 M x.5 M6 x M6 x. 5 Siebe VB9.. page 4 Johnson Controls VG3 VN, page 4 VG3 WN 4 B a STYLE B 3 mm 9 mm 0 Nm View the installation video for FGVL on Belimo's YouTube channel:
2 QUICK MOUNT VISUL INSTRUCTION MNUL FGVL Linkage with EV Series ctuators 5 Must be Flush with Bonnet BS Bring Level 6 Tighten Evenly 4 5 Nm 9 mm 5 Nm 3
3 9 QUICK MOUNT VISUL INSTRUCTION MNUL FGVL Linkage with EV Series ctuators 5 mm Tighten Evenly Nm 3 0 STOP Optional Lock and Manual Override Push daption for 3 Seconds with Power Must Snap Together 3
4 QUICK MOUNT VISUL INSTRUCTION MNUL FGVL Linkage with EV Series ctuators Optional SIEBE SIEBE DN min. / max. Temp. VB9 65 / C JOHNSON CONTROL JOHNSON CONTROLS DN min. / max. Temp. VG3 VN 65 / C VG3 WN 65 / C Isolate Valve First 4
5 WIRING DIGRMS Non-Spring Return ctuator with -3 QUICK MOUNT VISUL INSTRUCTION MNUL FGVL Linkage with EV Series ctuators Non-Spring Return ctuator with -SR 4 VC Transformer 3 Blk () Common Red () + Wht (3) + 4 VC Transformer 3 Blk () Common Red () + Wht (3) + 4 VC Transformer Control Signal ( ) VDC/m (+) Ω 500Ω /4 W 3 Blk () Common Red () + Hot Wht (3) Y Input, to 0 V Org (5) U Output, to 0 V On/Off Floating Point VDC / 4 to 0 m 00 to 40 VC 00 to 40 VC N L Hot H L Blu () Common Brn () + Wht (3) + N L Hot H L Blk () Common Brn () + Wht (3) + Signal Direction On/Off Floating Point Selector Switches BRN Brown Marron Brun Marrom 4 VC Transformer (C only) Hot Com Blk () Common 4 VC Transformer (C only) Hot Com Blk () Common Red () + Hot Red () + Hot BLU Blue zul Bleu zul Controller Wht (3) Y Input Controller Wht (3) Y Input Triac Sink Non-Spring Return ctuator with MFT 4 VC Transformer 3 Triac Source 4 VC Transformer 0 BLK Black Negro Noir Preto Notes: ORG Orange naranjado Orange laranjado ( ) to 0 VDC Feedback Signal (+) Blk () Common Red () Hot Wht (3) Y Input Org (5) U Output ( ) to 0 VDC Feedback Signal (+) B 9 Direction of rotation switch Blk () Common Red () + Hot Wht (3) Y Input Org (5) U Output to 0 V Meets culus requirements without the need of an electrical ground connection ctuators with appliance cables are numbered. ctuators may be connected in parallel. Power consumption and input impedance must be observed. PNK Pink Rosado Rosa Cor-de ros 3 ctuators may also be powered by 4 VDC. B B 5 Only connect common to neg. (-) leg of control circuits. On/Off 4 VC Transformer Control Signal ( ) VDC/m (+) Ω 500Ω /4 W 3 Blk () Common Red () + Hot Wht (3) Y Input, to 0 V Org (5) U Output, to 0 V Floating Point 4 VC Transformer (C Only) Ω B Control Signal ( ) C VDC/m (+) 500 Ω /4 W Functions a b c Min 0% Blk () Common Red () + Hot Wht (3) Y Input, to 0 V Org (5) resistor converts the 4 to 0 m control signal to to 0 VDC. Control signal may be pulsed from either the Hot (Source) or Common (Sink) 4 VC line. Contact closures & B also can be triacs. & B should both be closed for the triac source and open for triac sink. For triac sink the Common connection from the actuator must be connected to the Hot connection of the controller. Position feedback cannot be used with a triac sink controller. The actuator internal common reference is not compatible. WHT White Blanco Blanc Branco RED Red Rojo Rouge Vermelho Mid 50% Max 00% Normal Control mode acc. to Y IN4004 or IN400 diode. (IN400 supplied, Belimo Part number 4055) ctuators with plenum rated cable do not have numbers on wires; use color codes instead. VDC / 4 to 0 m Override Control Min, Mid, Max Postions 5
6 QUICK MOUNT VISUL INSTRUCTION MNUL FGVL Linkage with VK Series ctuators b STYLE mm optional /4 - UNF /4-3 UNEF 3 3/ - 4 UNF /6-0 UNF / - 0 UNF M x.5 M x M0 M x.5 M6 x M6 x. 5 4 B Optional Siebe VB9.. page 4 Johnson Controls VG3 VN, page 4 VG3 WN a STYLE B 3 mm 9 mm 0 Nm 6
7 QUICK MOUNT VISUL INSTRUCTION MNUL FGVL Linkage with VK Series ctuators 5 Must be Flush with Bonnet BS Bring Level 6 Tighten Evenly 4 5 Nm 9 mm 5 Nm 3
8 QUICK MOUNT VISUL INSTRUCTION MNUL FGVL Linkage with VK Series ctuators 9 5 mm Tighten Evenly Nm STOP Push daption for 3 Seconds with Power 3 0 Optional Manual Override Must Snap Together 3 M
9 QUICK MOUNT VISUL INSTRUCTION MNUL FGVL Linkage with VK Series ctuators Optional SIEBE SIEBE DN min. / max. Temp. VB9 65 / C JOHNSON CONTROL JOHNSON CONTROLS DN min. / max. Temp. VG3 VN 65 / C VG3 WN 65 / C Isolate Valve First 9
10 QUICK MOUNT VISUL INSTRUCTION MNUL FGVL Linkage with VK Series ctuators WIRING DIGRMS Electronic Fail-Safe ctuator with -3 4 VC Transformer 3 Blk () Common Red () + Hot 4 VC Transformer Blk () Common Red () Hot + Wht (3) Y Input Wht (3) Pnk (4) + Y Input Pnk (4) Y Input 9 On/Off Floating Point 00 to 40 VC N L Hot H L Blu () Brn () + 00 to 40 VC N L Hot H L Blu () Brn () + Wht (3) + Signal Direction Wht (3) + Wht (4) Wht (4) + Fail Postion 50% On/Off Floating Point Selector Switches 4 VC Transformer 4 VC Transformer 4 VC Transformer 4 VC Transformer 5 0 Hot Com Hot Com Blk () Common Blk () Common Hot Com Red () Hot + Red () Hot + Wht (3) Y Input Wht (3) Y Input Pnk (4) Y Pnk (4) Y Input Input 0 Blk () Common Red () Hot + Wht (3) Y Input Pnk (4) Y Input BRN Brown Marron Brun Marrom BLU Blue zul Bleu zul Controller Controller Controller Triac Sink Triac Source Triac Sink with Separate Transformer Electronic Fail-Safe ctuator with MFT 4 VC Transformer ( ) to 0 VDC Feedback Signal (+) Blk () Red () Wht (3) Org (5) 3 Common Hot Y Input U Output 4 VC Transformer ( ) to 0 VDC Feedback Signal (+) B 9 Direction of rotation switch Blk () Common Red () + Hot Wht (3) Y Input Org (5) 0 U Output to 0 V Notes: Meets culus requirements without the need of an electrical ground connection ctuators with appliance cables are numbered. ctuators may be connected in parallel. Power consumption and input impedance must be observed. ORG Orange naranjado Orange laranjado PNK Pink Rosado Rosa Cor-de ros B B 3 ctuators may also be powered by 4 VDC. 5 Only connect common to neg. (-) leg of control circuits. On/Off 4 VC Transformer 3 Floating Point 4 VC Transformer (C Only) 500 resistor converts the 4 to 0 m control signal to to 0 VDC. Control signal may be pulsed from either the Hot (Source) or Common (Sink) 4 VC line. WHT White Blanco Blanc Branco Control Signal ( ) VDC/m (+) Ω 500Ω /4 W Blk () Common Red () + Hot Wht (3) Y Input, to 0 V Org (5) U Output, to 0 V Min Mid Max Ω Control Signal ( ) VDC/m (+) 500 Ω /4 W Functions a b c 0% 50% 00% B C Blk () Common Red () + Hot Wht (3) Y Input, to 0 V Org (5) 9 0 Contact closures & B also can be triacs. & B should both be closed for the triac source and open for triac sink. For triac sink the Common connection from the actuator must be connected to the Hot connection of the controller. Position feedback cannot be used with a triac sink controller. The actuator internal common reference is not compatible. RED Red Rojo Rouge Vermelho Normal Control mode acc. to Y IN4004 or IN400 diode. (IN400 supplied, Belimo Part number 4055) ctuators with plenum rated cable do not have numbers on wires; use color codes instead. BLK Black Negro Noir Preto VDC / 4 to 0 m Override Control Min, Mid, Max Postions 0
11 QUICK MOUNT VISUL INSTRUCTION MNUL FGVL Linkage with RV Series ctuators b STYLE mm optional /4 - UNF /4-3 UNEF 3 3/ - 4 UNF /6-0 UNF / - 0 UNF M x.5 M x M0 M x.5 M6 x M6 x. 5 4 B Optional Siebe VB9.. page 4 Johnson Controls VG3 VN, page 4 VG3 WN a STYLE B 3 mm 9 mm 0 Nm
12 QUICK MOUNT VISUL INSTRUCTION MNUL FGVL Linkage with RV Series ctuators 5 Must be Flush with Bonnet BS Bring Level 6 Tighten Evenly 4 5 Nm 9 mm 5 Nm 3
13 9 QUICK MOUNT VISUL INSTRUCTION MNUL FGVL Linkage with RV Series ctuators 5 mm Tighten Evenly Nm STOP Push daption for 3 Seconds with Power 3 0 Optional Lock and Manual Override Must Snap Together 3
14 QUICK MOUNT VISUL INSTRUCTION MNUL FGVL Linkage with RV Series ctuators Optional SIEBE SIEBE DN min. / max. Temp. VB9 65 / C JOHNSON CONTROL JOHNSON CONTROLS DN min. / max. Temp. VG3 VN 65 / C VG3 WN 65 / C Isolate Valve First 4
15 B B WIRING DIGRMS Non-Spring Return ctuator with -3 QUICK MOUNT VISUL INSTRUCTION MNUL FGVL Linkage with RV Series ctuators 4 VC Transformer 0 Blk () Common Red () + Hot Wht (3) Y Input 4 VC Transformer B Direction of rotation switch 9 0 () Common Blk Red () Hot + Wht (3) Y Input Signal Direction On/Off Floating Point Selector Switches Non-Spring Return ctuator with MFT 4 VC Transformer ( ) to 0 VDC Feedback Signal (+) 3 Blk () Common Red () Hot Wht (3) Y Input Org (5) U Output 4 VC Transformer ( ) to 0 VDC Feedback Signal (+) B 9 Direction of rotation switch B B Blk () Common Red () + Hot Wht (3) Y Input Org (5) 0 U Output to 0 V Notes: Meets culus requirements without the need of an electrical ground connection ctuators with appliance cables are numbered. ctuators may be connected in parallel. Power consumption and input impedance must be observed. 3 ctuators may also be powered by 4 VDC. 5 Only connect common to neg. (-) leg of control circuits. BRN Brown Marron Brun Marrom 500 resistor converts the 4 to 0 m control signal to to 0 VDC. On/Off Floating Point Control signal may be pulsed from either the Hot (Source) or Common (Sink) 4 VC line. 4 VC Transformer Control Signal ( ) VDC/m (+) Ω 500Ω /4 W BLK Black Negro Noir Preto RED Red Rojo Rouge Vermelho WHT White Blanco Blanc Branco 3 Blk () Common Red () + Hot Wht (3) Y Input, to 0 V Org (5) U Output, to 0 V Min Mid Max 4 VC Transformer (C Only) Ω B Control Signal ( ) C VDC/m (+) 500 Ω /4 W Functions a b c 0% 50% 00% Blk () Common Red () + Hot Wht (3) Y Input, to 0 V Org (5) 9 0 Contact closures & B also can be triacs. & B should both be closed for the triac source and open for triac sink. For triac sink the Common connection from the actuator must be connected to the Hot connection of the controller. Position feedback cannot be used with a triac sink controller. The actuator internal common reference is not compatible. IN4004 or IN400 diode. (IN400 supplied, Belimo Part number 4055) BLU Blue zul Bleu zul ORG Orange naranjado Orange laranjado Normal Control mode acc. to Y ctuators with plenum rated cable do not have numbers on wires; use color codes instead. VDC / 4 to 0 m Override Control Min, Mid, Max Postions PNK Pink Rosado Rosa Cor-de ros 5
16 Subject to change. Belimo ircontrols (US), Inc. Belimo mericas US, Latin merica, and the Caribbean: Canada: Brazil: Belimo Worldwide:
GM24-MFT US. Proportional damper actuator, non-spring return, Multi-Function Technology
GM-MFT US Proportional damper actuator, non-spring return, Multi-Function Technology GM-MFT US Torque min. 0 in-lb Control to 0 VDC (DEFULT) Feedback to 0 VDC (DEFULT) pplication For proportional modulation
More informationWiring for Damper Actuators and Control Valves July 2011
Wiring for Damper ctuators and Control Valves July 011 Wiring for Damper ctuators and Control Valves eneral Wiring Instructions WRNIN: The wiring technician must be trained and experienced with electronic
More informationB350L, 3-Way, Diverting Ball Valve Chrome Plated Brass Ball and Nickel Plated Brass Stem
B350L, 3-Way, Diverting Ball Valve hrome Plated Brass Ball and Nickel Plated Brass Stem pplication This valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating
More informationF780HD, 3, 3-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc
F80HD, 3, 3-Way utterfly Valve Resilient Seat, 304 Stainless Steel Disc pplication Valve is designed for use in NSI flanged piping systems to meet the needs of bi-directional high flow HV hydronic applications
More informationB6400S-186, 2-Way, Characterized Control Valve Stainless Steel Ball and Stem
6400S-86, 2-Way, haracterized ontrol Valve Stainless Steel all and Stem pplication This valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating or cooling coils.
More informationB6400VB-350, 4, V Ball Control Valve Carbon Steel Body, Hardened Chrome Plated, Stainless Steel Ball and Stem
6400V-350, 4, V all ontrol Valve arbon Steel ody, Hardened hrome Plated, Stainless Steel all and Stem Product eatures ast quarter turn open or closed operation, Stainless steel ball and stem, Positive
More informationB212, 2-Way, Characterized Control Valve Stainless Steel Ball and Stem
, -Way, haracterized ontrol Valve Stainless Steel all and Stem pplication This valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating or cooling coils. Some
More informationB2150VB-055, 1-1/2, V Ball Control Valve Hardened Chrome Plated Carbon Steel Body, Stainless Steel Ball and Stem
50V-055, -/, V all ontrol Valve Hardened hrome Plated arbon Steel ody, Stainless Steel all and Stem Product eatures ast quarter turn open or closed operation, Stainless steel ball and stem, Positive shut-off,
More informationF680HD, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc
680H, 2-Way utterfly Valve Resilient Seat, 304 Stainless Steel isc Product eatures 200 psi (2 to 12 ) and 150 psi (14 to 24 ) 0% leakage, Long stem design allows for 2 insulation, Valve face-to-face dimensions
More informationP2050B050, 1/2, Pressure Independent Valve Chrome Plated Brass Ball and Brass Stem, NPT Female Ends
pplication The Pressure Independent haracterized ontrol Valve is typically used in air handling units on heating and cooling coils, and fan coil unit heating or cooling coils. Some other common applications
More informationF6125HD, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc
6125H, 2-Way utterfly Valve Resilient Seat, 304 Stainless Steel isc Product eatures 200 psi (2 to 12 ) and 150 psi (14 to 24 ) 0% leakage, Long stem design allows for 2 insulation, Valve face-to-face dimensions
More informationF650HD, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc
650H, -Way utterfly Valve Resilient Seat, 304 Stainless Steel isc Product eatures 00 psi ( to ) and 50 psi (4 to 4 ) 0% leakage, Long stem design allows for insulation, Valve face-to-face dimensions comply
More informationF6100HD, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc
6100H, 2-Way utterfly Valve Resilient Seat, 304 Stainless Steel isc Product eatures 200 psi (2 to 12 ) and 150 psi (14 to 24 ) 0% leakage, Long stem design allows for 2 insulation, Valve face-to-face dimensions
More informationB2 Series Characterized Control Valve, Spring Return Actuator
Series Characterized Control Valve, Spring ctuator Two-way Valve with Stainless Steel all and Stem, NPT Female Ends Service: Flow Characteristic: Media Temp Range: Maximum Differential: Pressure ( P) mbient
More informationP2075B100-P, 3/4, Pressure Independent Valve Chrome Plated Brass Ball and Brass Stem, NPT Female Ends
P2075100-P, 3/4, Pressure Independent Valve hrome Plated rass all and rass Stem, NPT emale nds pplication The Pressure Independent haracterized ontrol Valve is typically used in air handling units on heating
More informationP2050B005, 1/2, Pressure Independent Valve Chrome Plated Brass Ball and Brass Stem, NPT Female Ends
P2050005, 1/2, Pressure Independent Valve hrome Plated rass all and rass Stem, NPT emale nds pplication The Pressure Independent haracterized ontrol Valve is typically used in air handling units on heating
More informationF6 Series 2-Way, Victaulic Butterfly Valve
F6 Series 2-Way, Victaulic Butterfly Valve 200 psi (2 to 12 ) bubble tight shut-off Long stem design allows for 2 insulation Completely assembled and tested, ready for installation Application These valves
More informationBall Valve Features and Benefi ts B2...VS / VSS and B3...L
all Valve Features and enefi ts 2...VS / VSS and 3...L Tech.Doc - 07/17 - Subject to change. elimo ircontrols (US), Inc. 2-way and 3-way confi guration ronze with stainless steel trim (2-way) Nickel plated
More informationTechnical Documentation Electronic Characterized Control Valves (CCV)
Technical Documentation Electronic Characterized Control Valves (CCV) Effective March 005 Table of Contents Control Valve Product Range... Valve/ctuator Selection t Glance...4 Electronic Characterized
More informationLM Series Direct Coupled Actuator
LM Series Direct Coupled Actuator Small Yet Powerful Minimum in-lb torque in a compact package. For damper areas up to 8 sq-ft*. Quiet Plus VAV terminal unit by Warren Technology Areas of Application VAV
More informationF6100HD, 4, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc
6100H, 4, 2-Way utterfly Valve Resilient Seat, 304 Stainless Steel isc pplication Valve is designed for use in NSI flanged piping systems to meet the needs of bi-directional high flow HV hydronic applications
More informationV Ball Control Valve Product Range
V all ontrol Valve Product ange VSI all Valve Product ange...v, 6...V Type Suitable ctuators v Inches DN [mm] -way NPT Flange Spring eturn Electronic Fail-Safe Non-Spring eturn 4 1 5 00V-04 55 1½ 40 50V-055
More informationB250, 2-Way, Characterized Control Valve Stainless Steel Ball and Stem
250, 2-ay, haracterized ontrol Valve Stainless Steel all and Stem pplication This valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating or cooling coils.
More informationG2, G3 NPT Screwed Globe Control Valves
4-0000. INSTUCTION MNUL G, G NPT Screwed Globe Control Vlves G (S) Series NPT Screwed Globe Vlves Technicl Dt G G...S Service chilled or hot wter, 6 glycol, stem Flow chrcteristic modifi ed equl percentge
More informationGlobe Valve Actuators
28 The Forta is a family of actuators for the control of 2 way and 3 way globe valves. The Forta has a very fine resolution PCBA board which ensures good rangeability of the valve. The software in the
More informationB240, 2-Way, Characterized Control Valve Stainless Steel Ball and Stem
0, 2-ay, haracterized ontrol Valve Stainless Steel all and Stem pplication This valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating or cooling coils. Some
More informationProvides line voltage capable single Pole Double-Throw (SPDT) switch and 140Ω, 1KΩ, 2KΩ or 10KΩ feedback potentiometric.
VA9310 Non Spring Return Actuators Product Bulletin The VA9310 Series Electric Non Spring Return Actuators are used to provide accurate positioning on Johnson Controls VG1000 Series DN15 up to DN50 ball
More informationSpring Return DuraDrive Proportional Actuator
MS40-7043, MS4-7073, MS4-753 Spring Return DuraDrive Proportional Actuator For spring return applications that require proportional modulation control of dampers and valves in HVAC systems. Features: Proportional
More informationModulating controlled actuators AME 10, AME 20, AME 30 AME 13, AME 23, AME 33 - with DIN EN certified safety function (spring down)
Data sheet Modulating controlled actuators AME 10, AME 20, AME 30 AME 13, AME 23, AME 33 - with DIN EN 14597 certified safety function (spring down) Description AME 10 AME 13 AME 20, AME 30 AME 23, AME
More informationNon-Spring Return EconoDrive Proportional Actuator
MSD-0x3 Series Non-Spring Return EconoDrive Actuator EconoDrive overshaft actuators are designed to provide an economical and reliable solution for many overshaft damper and ball valve requirements. All
More informationPower consumption In operation At rest For wire sizing. Auxiliary switch NRF24A-SR-S2 NRF24A-SR-S2-O
echnical data sheet NRF24A-SR-S2(-O) Modulating rotary actuator with emergency function for 2- and 3-way ball valves orque or ue 10 Nm Nominal voltage AC/DC 24 V Control: modulating DC 0... 10 V Position
More informationManual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool
echnical data sheet LMA-MF-P Multifunctional damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx.
More informationNon-Spring Return DuraDrive Modulating Actuator
MS41-60xx Series n-spring Return DuraDrive Modulating Actuator The DuraDrive direct coupled 24 Vac non-spring return rotary electric actuators are designed for modulating control of dampers. S41-60xx ries
More informationTechnical data. Parameterisable damper actuator in the
echnical data sheet Parameterisable damper actuator in the IP66 protective housing for or adjusting ad usting air dampers in industrial plants and in technical building installations For air dampers up
More informationTechnical data V phase cut, input impedance 8.2 k Position feedback (measuring voltage U) DC V, max. 0.5 ma Start point DC
echnical data sheet SMA-PC Parameterisable damper actuator for adjusting air dampers in ventilation and air-conditioning systems in buildings Air damper size up to approx. m orque 0 Nm Nominal voltage
More informationAC/DC 24 V, 50/60 Hz. Functional data Variable Settings. DC V, max. 0.5 ma. End point DC V... 4 ma ma Non-variable
echnical data sheet S--MF- Multifunctional rotary actuator for butterfly valves orque 00 Nm Nominal volta e V Control: ontrol configurable confi urable Position feedback: configurable Auxiliary u iliary
More informationTechnical data. T2-SM230ASR en v Subject to changes / 3. Electrical data Nominal voltage AC
echnical data sheet SMASR Modulating damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx. 4 m orque Nm
More informationFunctional data Factory settings Variable Settings
echnical data sheet Rotary actuator RF-MF(-O) Multifunctional rotary actuator with emergency control for and 3 way control ball valve orque Nm Nominal voltage AC/DC V Control: Modulating DC... V or variable
More information21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque
echnical data sheet GK4A- Communicative SuperCap rotary actuator with emergency setting function and extended functionalities for adjusting air dampers in ventilation and air-conditioning systems for building
More information11 VA Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque (nominal torque) Motor Spring return
echnical data sheet SF24A- Communicative spring return actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx.
More informationBATCHMATE 1500 Batch Control Computer Technical Bulletin
TS-5(C) BATCHMATE 5 Batch Control Computer Technical Bulletin DESCRIPTION The BATCHMATE features an 8 digit.55-in. alphanumeric LED display. The pulse input model will accept up to 2, pulses per second
More informationProximity Sensor Terminology
The following descriptions refer to the European standard EN 60947-5-2. of 2007. The specifications given here are intended to be minimum performance values described by the standard. Alignment must not
More informationPROXIMITY SENSOR TERMINOLOGY
Never use this desk reference for installation or operation of equipment. Refer to manual for installation and operation instructions. The following descriptions refer to the European standard EN 60947-5-2.
More informationINSTALLATION INSTRUCTIONS Z7800 SERIES MORTISE LOCK
801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com A. Door Preparation: INSTALLATION INSTRUCTIONS Z7800 SERIES MORTISE LOCK 1. Measure desired height
More informationF6/F7...HD/HDU Series Butterfl y Valves
71150-00001. INSTLLTION N MINTENNE INSTRUTIONS F6/F7...H/HU Series utterfl y Valves F6 HU utterfly Valves 2 12 uctile Iron Lug ody Resilient Seat, 304 Stainless isc 50 psi bubble tight shut-off Long stem
More informationPower consumption In operation At rest For wire sizing. 150 s / C Sound power level Motor. Emergency setting function 61 db (A)
echnical Data sheets GRK4A-SR-5 Modulating SuperCap rotary actuator with emergency setting function and extended functionalities for butterfly valves and ball valves with mounting flange ISO 511-F05 orque
More informationICM/ICAD Motorized Valve. Quick Start Guide. Installation, Programming, and Trouble-shooting REFRIGERATION & AIR-CONDITIONING
Installation, Programming, and Trouble-shooting REFRIGERATION & AIR-CONDITIONING Quick Start Guide Contents Page Installation...............................................................................................3
More informationOverview of types. Technical data
echnical data sheet SHA-.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control dampers
More informationPower consumption In operation At rest For wire sizing
echnical data sheet GM4A-SR-P Modulating damper actuator for operating air control dampers in ventilation and airconditioning systems for building services installations For air dampers up to approx. 8
More informationElectro Controls. Input-Output Modules WattsIndustries.co.uk
Electro Controls Input-Output Modules - 2017 WattsIndustries.co.uk Input-Output Modules Section 08 B.M.S INPUT - OUTPUT MODULES SINGLE AND ADJUSTABLE RELAY ESRM.. Volt free contacts DIN RAIL mounted relay
More informationPower consumption In operation At rest For wire sizing
echnical data sheet MC4A-SR-F Modulating damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx..4 m orque
More informationActuators for modulating control AME 85, AME 86
Data sheet Actuators for modulating control AME 85, AME 86 Description The actuators AME 85 and AME 86 are used with VFM 2 (DN 50-250), VFS 2 (DN 65-00), VF2/3 (DN 25, 50) and AFQM (DN50-250) valves. Features:
More information1A POWER SUPPLY K1823
Total solder points: 27 Skill level : 1 1A POWER SUPPLY K1823 Applications : Just add a suitable transformer (see table inside) Great to power your projects and save on batteries Use as adjustable power
More informationMG350V Globe Valve SmartX Actuator
MG350V Globe Valve SmartX Actuator schneider-electric.com * Product Description MG350V globe valve actuators are non-spring return electromechanical actuators for the control of two-way and three-way globe
More information7000 Series Bronze Globe Valves Two-Way Normally Open
7000 Series Bronze Globe Valves Two-Way Normally Open / to in. Screwed NPT Two-Way Normally Open Spring Return Stem Up Open Globe Valves Two-Way Normally Open Assemblies Size in. / /4 Cv (K vs ) 0.4 (0.4).
More informationICM/ICAD Motorized Valves Installation, Programming, and Troubleshooting
Quick Start Guide ICM/ICAD Motorized Valves Installation, Programming, and Troubleshooting The ICM motorized valve is comprised of up to 4 components: the valve body often referred to as the ICV body because
More informationDCS-62 Series Spring Return Electronic Actuator Product Bulletin
Delta Control Products, Inc. 0 West Rose Garden Lane Phoenix, Z 807 6-780-08 DCS-6 Series Spring Return Electronic ctuator Product ulletin Description The Delta DCS-6 direct-coupled spring return electronic
More informationManual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool
echnical data sheet SMA--P Multifunctional damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx. m orque
More information658 Current to Position Converters
658 Current to Position Converters Current to Position Converters for Solid State Switching Output Adjustable Zero, Span and Deadband Two Wire Input from Controller Operates with 90 to 1000 Ω Feedback
More informationTechnical data. Safety notes. T3-LR24A-SR en v Subject to changes 1 / 2
echnical data sheet LR4A-SR Modulating rotary actuator for and -way control ball valves orque Nm Nominal voltage AC/DC 4 V Control: Modulating DC... V Position feedback: DC... V echnical data Safety notes
More informationPHASE CUT SIGNAL DRIVERS
FEATURES Input to output isolation 27, 40 or 80 watts output power Fused 24VAC power supply Input and power LED indication DESCRIPTION & OPERATION The Digital Controller Interface Module Phase Cut Driver
More informationContrast scanners detect the little differences
KT /KT Contrast scanners Contrast scanners Contrast scanners detect the little differences Adjustment of the standard version is carried out manually. The contrast scanner has an integrated adjustment
More informationPower consumption In operation At rest For wire sizing
echnical data sheet SM4A-SR-P Modulating damper actuator for adjusting air dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx. 4 m orque
More information2-way zone valve QCV TM
2-way zone valve QCV TM / ZoneTight TM Table of contents Introduction 2 Type key 2 Product features 2 Adjustable angle of rotation 2 kv setting 2 Adaption 2 Operating range 3 Selection and dimensioning
More informationExplosion proof rotary actuator - On/Off or programmable regulating actuator
Explosion proof rotary actuator - On/Off or programmable regulating actuator Direct mounting for quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Type 3004 can
More informationSTANDARD WIRING DIAGRAMS FOR SMART MODEL 20
CODING SYSTEM FOR AV ACTUATOR WIRING DIAGRAMS There are 3 elements to the wiring codes used in AVA electric actuators: WIRING CODE 1 3 Wire system, single pole double throw, switching the live SPDT 2 3
More informationB2...VS Series, 2-way, Ball Valve Bronze Body, Stainless Steel Ball and Stem
2...VS Series, 2-way, all Valve ronze ody, Stainless Steel all and Stem Live-load packing set Stainless steel ball & stem low-out proof stem design Technical Data Media chilled or hot water, glycol, #
More informationECB-103 BACnet B-ASC 10-Point Programmable Controllers
D a t a s h e e t BACnet B-ASC 10-Point Programmable Controllers Overview The is a microprocessor-based programmable controller designed to control terminal units such as fan coil unit, heat pump unit,
More informationTechnical data sheet. Technical data. Safety notes
echnical data sheet LM4A-F Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx. m orque 5 Nm Nominal
More information3DM phase Digital Stepper Drive
3DM2283 3-phase Digital Stepper Drive 150-220VAC, 0.5-8.2A peak, Auto-configuration, Low Noise Anti-Resonance provides optimal torque and nulls mid-range instability Motor auto-identification and parameter
More informationAWA W valve amplifier. S.N. Z177. Gratis Stephen (Brucer) Nov, 2014
9/01/015 AWA PA87 AMPLIFIER Page 1 of 8 1. Summary AWA 87 0W valve amplifier. S.N. Z177. Gratis Stephen (Brucer) Nov, 014 MIC-Phono input channel PA amplifier. 1AX7 mic preamp. 1AX7 mixer with feedback
More informationTwo channel codelock receiver
Total solder points: 224 Difficulty level: beginner 1 2 3 4 5 advanced Two channel codelock receiver K6727 Features: Easy to build: no coils to be made! Works together with the K6706/K6706A two channel
More information6-Ton Hydraulic Cutting/Crimping Platform
6-Ton Hydraulic Cutting/Crimping Platform 1-855-798-6657 SOUTHWIRETOOLS.COM 2017 Southwire Company, LLC. All rights reserved. Registered Trademark and Trademark of Southwire Company, LLC. MAXTERM 6-TON
More informationElectrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing
echnical data sheet Rotary actuator LR4A Rotary actuator for and -way (control) ball valves orque 5 Nm Nominal voltage AC/DC 4 V Control: Open/close or -point echnical data Electrical data Nominal voltage
More informationProduct overview. Features. Product specifications. Order codes. 1kΩ Resistance Output Module
Product overview The AX-ROM135 and the AX-ROM1000 Modules enable an Analogue, Pulse or Floating point signal and convert to either a 0-135Ω or a 1KΩ Proportional Resistive output signal. The output resistance
More informationPhotoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems
WLL 0(T) Photoelectric switches Photoelectric switches with fibre-optic cable Proximity mode Photoelectric switches with fibre-optic cable Through-beam mode Photoelectric switches WLL 0(T), fibre-optic
More informationRotary gear motor series AG8...
Rotary gear motor series AG8... The electric actuator belonging to AG8 series is designed to operate gas valves and air dampers in ventilation and air conditioning systems. The compact design and universal
More informationApplication Solutions for: Analog (Input /
Application Solutions for: Analog (Input / Output), Pneumatic (Input / Output), Pulse (Input / Output), Resistive (Input / Output), Floating Point (Input / Output), DDC Control, Compressor Staging, Chiller
More informationANALOG SENSORS. Analog sensors give a signal output which is proportional to sensing distance.
LOAD LOAD LOAD LOAD PART K0 ~ K7 ANALOG S Diameter Shielded nonshielded Sensing Distance Sn mm Housing Material With LED Without LED Dimensions (Unit: mm) Features Analog sensors give a signal output which
More informationD7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information
with Linear Output or Manual Setting Detects Changes in Machine ON/OFF output can be set and checked quickly and easily from the vibration level meter. waveforms can be checked using the AC monitor output.
More informationKnight Handpiece Illumination System [153693, (120VAC) , (240 VAC)]
Knight Handpiece Illumination System [153693, 153695 (120VAC) 153694, 153696 (240 VAC)] For installation in Knight Units mounted to Console, LR, Duo Cart, Hygienist Cart or Doctor s Cart. Applies to Models:
More informationRamp/Soak Temperature Controller REX-P250
EX-P0 General The EX-P0 is a high performance ramp/soak controller with a storage capacity of segments in patterns. Each pattern consists of up to segments and patterns can be linked for maximum pattern
More informationBrief description. Type overview
echnical data sheet VAV-Compact KNX A pressure sensor, digital VAV controller and damper actuator all in one, providing a VAV-Compact solution with a communications capability for pressureindependent VAV
More informationCL86T. 24~80VDC, 8.2A Peak, Closed-loop, No Tuning. Descriptions. Closed-loop. Stepper. Applications. Datasheet of the Closed-loop Stepper CL86T
CL86T Closed-loop Stepper 24~80VDC, 8.2A Peak, Closed-loop, No Tuning Closed-loop, eliminates loss of synchronization Broader operating range higher torque and higher speed Reduced motor heating and more
More informationOverview of types. Technical data. T5-NRDVX24-SR-T-.. en v Subject to changes 1 / 3
echnical data sheet NRDVX4-SR--.. Modulating short stroke actuator for the motorisation of Cazzaniga and Siemens short stroke valves in HVAC systems Nominal stroke max. 5.5 mm Actuation force 500 Nm Nominal
More information2007 Technical Documentation Pressure Independent Characterized Control Valves (PICCV) Patented
2007 Technical Documentation Pressure Independent Characterized Control Valves (PICCV) Patented Effective December 2007 Table of Contents Control Valve Product Range...2 Valve /Actuator Selection At A
More informationTechnical data. Safety notes. Power consumption In operation At rest For wire sizing
echnical data sheet Damper actuator NM4A-SR-P Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations For air control dampers up
More informationDrawing 1 T14 T11 TR1 TR2 R(BIAS) T12 T13 T10 TOP REAR FRONT GROMMET 4 GROMMET 2 GROMMET 1 GROMMET 3 GROMMET 5 TR2 TR1 TR2 TR2 #6 #6 #6 #6 #10 #10 #10
Drawing TOP REAR V V V V T T TR TR TR TR GROMMET SIDE GROMMET SIDE GROMMET TR TR TR GROMMET TR GROMMET T T T FRONT Drawing V V V V T T TR TR TR TR GROMMET GROMMET COLD HOT GROMMET TR TR TR GROMMET TR GROMMET
More informationDCIM SIGNAL CONVERTERS
DCIM SIGNAL CONVERTERS FEATURES Optically isolated inputs Fused 24V AC power supply Field adjustable output Input & power LED indication Optional minimum position pot APPLICATIONS Phase cut to ma/v DC
More informationElectrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet GR24A--R Communicative Retrofit rotary actuator for rotary valves and butterfly valves Nominal torque 40 Nm Nominal voltage AC/DC 24 V Control Modulating DC (0)2...10 V Variable Position
More informationonlinecomponents.com
Analog Photoelectric Sensor Analog Output Proportional to Light Received, Ideal For Inspection and Measurement Analog object detection ideal for position, size, color and surface characteristics Both analog
More informationControl Unit Series 8208
> Installation of various components such as Snap action switch Potentiometer Relay Time relay Diodes Fuses Resistors www.stahl.de 01776E00 Components of various functions such as diodes, resistors, fuses
More informationElectronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards
Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards The Solo, Select and Sync PWM boards provide a pulse-width modulated (PWM) signal to the EC motor to control fan speed.
More information[ ] kvs theor.: Theoretical kvs value for pressure drop calculation Vmax low-n: Vmax for low-noise operation
echnical data sheet EP..R-R6+BAC Characterised control valve with sensor-operated flow control, 6-way, Internal thread, PN 16 (EPIV) Nominal voltage AC/DC 24 V Control modulating, communicative wo sequences
More informationActuators for modulating control AME 55, AME 56
Data sheet Actuators for modulating control AME 55, AME 56 Description The actuators AME 55 and AME 56 are used with VL 2, VL 3 or VFS 2 valves from DN 65 up to DN 100 diameter or VF 2, VF 3 valves from
More informationPower consumption Operation At rest Wire sizing
echnical data sheet NM24P-SR Modulating Robustline damper actuator for operating air dampers in industrial plants and in the technical building installations For air dampers up to approx..6 m 2 orque 8
More informationANALOG SCALING MODULE
ANALOG SCALING MODULE FEATURES 24V AC operation Output can sink input s pull-up voltage Optional Zero & Span potentiometers Small size 1.10" by 2.19" Two mounting options APPLICATIONS Analog 0 to 5V DC
More informationElectrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet LR24A-KNX Communicative rotary actuator for ball valves Nominal torque 5 Nm Nominal voltage AC/DC 24 V Control modulating Conversion of sensor signals Communication via KNX (S-Mode)
More informationB6300VB-207, 3, V Ball Control Valve Carbon Steel Body, Hardened Chrome Plated, Stainless Steel Ball and Stem
6300V-207, 3, V all ontrol Valve arbon Steel ody, Hardened hrome Plated, Stainless Steel all and Stem Product eatures ast quarter turn open or closed operation, Stainless steel ball and stem, Positive
More informationK2655. Electronic watchdog. Features: Specifications :
Total solder points: 101 Difficulty level: beginner 1 2 3 4 5 advanced Features: Electronic watchdog K2655 Very realistic simulation through the use of a random generator. Choice of two different dogs.
More information