Control Unit Series 8208
|
|
- Charleen Jenkins
- 5 years ago
- Views:
Transcription
1 > Installation of various components such as Snap action switch Potentiometer Relay Time relay Diodes Fuses Resistors E00 Components of various functions such as diodes, resistors, fuses and relays are integrated in the Ex d enclosure The shown functions are standardised, other customer orders are available on request. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division For use x x x x For use in x *) x *) x *) x *) For use in x *) *) Canada WebCode 8208A Control Panels, Distribution Panels and Components /1
2 Version Description Resistance values with open-circuit and short-circuit detection 1 NO / 1 NC, positive opening 10 k Ω / 1 k Ω Schematic Order number Weight 8208/ E00 1 NO / 1 NC 10 k Ω / 1.8 k Ω 8208/ Snap switch 11042E00 1 NO / 1 NC.1 kω / 681 Ω 06755E / NO / 1 NC 2 NC, positive opening 10 k Ω / 1 k Ω 06755E E / / NC 10 k Ω / 1.8 k Ω 06757E / NC 2 NO 10 k Ω / 1 k Ω 06757E E / / NO 06756E E00 For actuators see control buttons Series / E II 2 G E I M 2 Contact block Rated operational current Rated operational voltage Contact resistance Contact material AC-15: 1.5 A DC-13: 0.5 A AC-15: 230 V DC-13: 60 V typical 10 m Ω gold /2 Control Panels, Distribution Panels and Components
3 Resistors C see table T surface = max. 80 C T surface = max. 80 C 2.0 W 1.0 W Enclosure material Polyamide 2.5 mm 2 finely stranded (screw terminals) 8208/24-15 Snap switch 08642E00 Control Panels, Distribution Panels and Components /3
4 Version Schematic Resistance values Order number Weight E00 1 k Ω 8208/ k k Ω 8208/ k k Ω 8208/ k Resistance values 8208/ see order number supplement Potentiometer 10028E00 Order Number Supplement Other resistance values for 8208/ Ω 100 k Ω 1M Ω 0 Ω 2.2 k Ω k Ω 0 k Ω 47 k Ω 470 k Ω Example: Potentiometer with resistance value 100 Ω : 8208/ K / M / M0 8208/ K 8208/ K2 8208/ K 8208/ M 8208/ K 8208/ M / K10 Version Assembly Description Order number Weight Actuators Series 8602A 04496E A with scale: A A with scale: A A with scale: A E II 2 G E I M 2 Rated insulation voltage max. 500 V Rated operational power 2 W Resistance values 100 Ω... 1 M Ω Characteristic curve linear Resistance tolerance ± 20 % Resistor material Carbon composition Circuit diagram Stop strength ) 100 Ncm 06065E00 /4 Control Panels, Distribution Panels and Components
5 Enclosure material Polyamide Rotation range 270 Torque Ncm 2.5 mm 2 flexible C see table T surface = max. 80 C T surface = max. 80 C 2.0 W 1.0 W The switching capacity of the line side fuse of the potentiometer must be equal or larger than the maximum short circuit current (max. 3xI B acc. to IEC ). 67 [2,64] Ø 4 [Ø 0,16] Ø 2 [Ø 0,08] 8208/24-08 Potentiometer Potentiometer actuator assembly code E ø 45 [ ø 1, 77] [1, 26] 04431E00 Control Panels, Distribution Panels and Components /5
6 Version Description Rated operational voltage 1 NO 24 V AC Schematic Order number Weight / E V AC / Relay 03879E V AC E / E00 24 V DC 13 L- 8208/ L E00 1 NC 24 V AC / E V AC / E V AC / E00 24 V DC 11 L- 8208/ L E00 E II 2 G E I M 2 /6 Control Panels, Distribution Panels and Components
7 Rated operational current Enclosure material 5 A C see table T surface = max. 80 C T surface = max. 95 C T surface = max. 80 C T surface = max. 95 C 3.0 W 4.75 W 1.5 W 2.0 W Polyamide 2.5 mm 2 flexible 01877E /14-06 Relay Control Panels, Distribution Panels and Components /7
8 Version Time domain Rated operational voltage Order number Weight 5 min 24 V AC 8208/ V AC 5min V AC 8208/ V AC 5min V DC 8208/ V DC 5min min 230 V AC 8208/ V AC 15min Time relay 03879E00 E II 2 G E I M 2 Rated operational current Enclosure material 5 A C see table T surface = max. 80 C T surface = max. 95 C T surface = max. 80 C T surface = max. 95 C 3.0 W 4.75 W 1.5 W 2.0 W Polyamide 2.5 mm 2 flexible 8208/14-14 Time Relay 01877E00 /8 Control Panels, Distribution Panels and Components
9 Version Description Schematic Order number Weight 2 diodes 1N / Diode 03879E00 3 diodes 1N diodes 1N E E / / Transient voltage suppression diode E / E II 2 G E I M E00 4- Rated operational voltage Rated operational current Enclosure material 500 V 1 A C see table T surface = max. 80 C T surface = max. 95 C T surface = max. 80 C T surface = max. 95 C 3.0 W 4.75 W 1.5 W 2.0 W Polyamide 2.5 mm 2 flexible 8208/14-02 Diode 01877E00 Control Panels, Distribution Panels and Components /9
10 Version Description Schematic Order number Weight 1 fuse 2 fuses 1 2 2A a.a E E / / E00 Fuse E II 2 G E I M 2 Rated operational voltage Max. breaking capacity 500 V AC 50 A AC C see table T surface = max. 80 C T surface = max. 95 C T surface = max. 80 C T surface = max. 95 C 3.0 W 4.75 W 1.5 W 2.0 W Enclosure material Polyamide 2.5 mm /14-12 Fuse 01877E00 /10 Control Panels, Distribution Panels and Components
11 Version Resistor 03879E00 Resistance values Power Rated operational voltage 15 Ω k Ω 1 x 2 W max. 75 V T5 0.1Ω... MΩ 2 x 0.5 W max. 350 V T6 0.1Ω kω 2 x 1 W max. 500 V T6 E II 2 G E I M 2 Temperature class Schematic Order number Weight E E E / resistor 2W 8208/ resist. 0,5W 8208/ resistors 1W Rated operational voltage max. 500 V Resistance tolerance ± 10 % C see table Enclosure material Resistor material Polyamide Metal film 2.5 mm 2 flexible T surface = max. 80 C T surface = max. 95 C T surface = max. 80 C T surface = max. 95 C 3.0 W 4.75 W 1.5 W 2.0 W /14-02 Diode 01877E00 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. Control Panels, Distribution Panels and Components /11
Single-Channel Safety Barriers Series 9001
Single-Channel Safety Barriers Series 9001 > Broad product range for all standard applications in the world of automation > Flexible and space saving single and dual channel versions available > Time saving
More informationSingle-Channel Safety Barriers with Electronic Current Limitation Series 9004
Single-Channel Safety Barriers with Electronic Current Limitation > Broad product range for all standard applications in the world of automation > Flexible and space saving > Time saving installation due
More informationTwo-channel safety barriers Series 9002
Two-channel safety s Series 00 > Wide product range for all standard applications of the automation > Flexible and space-saving available in single and double channel versions > Time-saving installation
More informationTwo-channel safety barriers Series 9002
Two-channel safety s Series 00 > Wide product range for all standard applications of the automation > Flexible and space-saving available in single and double channel versions > Time-saving installation
More informationBinary Output Series 9175
Binary Output > Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring (can be switched off) > For use
More informationIsolating Repeater Input Series 9163
> For 4-wire HART transmitters and voltage sources > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2 (IEC 61508) > High accuracy www.stahl.de
More information06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500
Switching Repeater Series 9170 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit / short-circuit monitoring and messaging (can be switched
More informationTemperature Input Module for Zone 1 Series 9482/32
www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >
More informationActuators Series 8602/3
> Large selection of actuators Pushbuttons Mushroom pushbuttons Rotary actuators Key-operated switches Mushroom stay-put buttons with key lock Mushroom stay-put buttons Twin pushbuttons Illuminated pushbuttons
More informationDigital Input Output Module 24 V for Ex n Zone 2 Series 9472/35
www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up
More informationBinary Output without Power Supply Series 9176
Binary Output without Power Supply Series 9176 > For intrinsically safe operation of Ex i solenoid valves, indicators and horns > Power supply by control circuit, loop powered > Intrinsically safe output
More informationDigital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22
www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160
Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de
More informationLocal control stations for Zone 1 and Zone 21. Features. Description
Local control stations for Zone and Zone Local control stations for Zone and Zone Features The right size/material enclosure Optimum functionality thanks to the great variety of components Customised planning
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F
Series 9160 Rev. F > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de
More informationDigital Input Output Module for Zone 1 Series 9470/32
www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used
More informationHMI Components. Series. Flush design Raised design PCB (with adaptor) Indicator Pushbutton Illuminated pushbutton
Edition /204 HMI Components 8 Series Characteristics The compact 8 mm Series 8 is especially suited for: Flush design Raised design PCB (with adaptor) Functions The Series 8 incorporates the following
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series
Transmitter Supply Unit Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring and messaging for input
More informationDigital Input Output Module for Zone 2 Series 9470/33
www.stahl.de > 16 channels can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8
More informationAnalog Universal Module HART for Zone 2 Series 9468/33
> 8 channels can be adjusted individually as analog inputs or outputs > Intrinsically safe inputs/outputs Ex ia > For 0/4 20 ma + HART signals > Line fault monitoring per channel > Diagnostics based on
More informationIsolators A3/1. Vibration Transducer Supply Unit Series
> For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 khz > Easy setting by means of front-side rotary switch > Galvanic
More informationDigital Input Output Module for Zone 2 Series 9470/33
www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used
More information09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i
Temperature Transmitter Series 9182 www.stahl.de > One unit for nearly all temperature sensors indivdually configurable > Intrinsically safe input [Ex ia] IIC > Signal duplication possible > Galvanic isolation
More informationSignal Beacon - LED Series 6162
www.stahl.de > Versions rotating mirror beacon rotating beacon beacon with double flash (9 + 5 J) flashing beacon (15 J) LED-continuous beacon LED-rotating beacon > Seawater resistant aluminium enclosure
More information2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004
2 Safety Barriers Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 Broad product range for all standard applications in the world of automation Flexible and space saving Time
More informationIsolators A3/1.
> Compact limit value switch with 2 configurable limiting values and 4... 20 ma output > Suitable for 2-, 3-wire transmitters, 2-wire HART transmitters and ma sources > Intrinsically safe input [Ex ia]
More informationAnalog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/
> 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More informationIsolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No
9165/16-11-10s 207909 Compact one- and two-channel Ex i output isolating repeater wire-breakage and short-circuit monitoring system, which can be disconnected and features a signalling contact can be used
More informationIsolators A3/1.
Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration
More informationIsolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series
Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration
More informationEMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.
Electronic monitoring relay for voltage monitoring in three-phase networks INTERFACE Data sheet 102110_en_03 1 Description PHOENIX CONTACT - 09/2009 Features Increasingly higher demands are being placed
More informationUniversity of Technology, Jamaica School of Engineering. Electrical Workshop Notes On Electrical components
University of Technology, Jamaica School of Engineering Electrical Workshop Notes On Electrical components Resistors Resistors are fundamental components in electronic circuits. A resistor is constructed
More informationSubject to changes 11/2003 Page 1/7
Main Characteristics: Zero switching. LED display. Various connection systems. Plug-in control terminal. Degree of protection IP 2. Double-insulated design. General Data: Standards / Approvals DIN EN 697--3
More informationMACX MCR-UI-UI-UP(-SP)(-NC)
Configurable 3-way isolating amplifier with safe isolation and wide-range power supply Data sheet 04247_en_02 PHOENIX CONTACT 203-04-0 Description MACX MCR-UI-UI 3-way isolating amplifiers are used to
More informationIsolators A3/1. Ex i Power Supply Field Circuit Ex i Series
> Intrinsically safe output [Ex ib] IIC/IIB > Stable output voltage > Galvanic isolation between output and power supply > Power supply or 85... 230 V AC > Compact design www.stahl.de 07673E00 Basic function:
More informationMACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:
Extract from the online catalog MACX MCR-EX-T-UI-UP Order No.: 2865654 Freely programmable Ex-i temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer
More informationFieldbus Isolating Repeater Series 9185/11
www.stahl.de > For operation of the intrinsically safe Profibus DP (RS-485 IS to PNO standard) > Intrinsically safe fieldbus RS-422, RS-485 [Ex ib] IIC > Galvanic isolation between RS-422 / RS-485, RS-232,
More informationAssembly. Front view. Parametrization interface. Power Bus
Temperature Converter Features Assembly 1-channel signal conditioner 24 V DC supply Thermocouple, RTD, potentiometer or mv input Input for PTC thermistor Current and voltage output Line fault (LFD) and
More informationOutput of three-phase motors at 50 Hz and 400 V
RT0, RH Coupling Relays (Interfaces) Description DC operation IEC 0 947 and EN 0 947 (VDE 00) The RT0 coupling relays for switching motors and RH for auxiliary circuits are laid out to the special requirements
More informationElectronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet
1SVR 430 103 F0200 CT-ERS 1 7 2 6 5 4 8 3 1 10 selectable time ranges, from 0.05 s to 300 h 2 Potentiometer with direct reading scale for the fine adjustment of the time delay 3 Sliding switch to set the
More informationDigital Input Module 24 V Ex n Inputs, 16 Channels Series 9471
> 16 channels for active 0 / 24 V signals > Zone 2 / Division 2 version for connection of circuits acc. to Ex nl, Ex na, Nonincendive and Non-Ex > Galvanic separation between inputs and system > Two channels
More informationRelays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:
RU Series Universal Relays Key features: Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator
More informationElectronic timer CT-SDD.22
CDC 099 F0t0 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied W
More informationKnob Potentiometer with Switch
Knob Potentiometer with Switch, The is a revolutionary concept in panel mounted potentiometers. This unique design consists of a knob driving and incorporating a cermet potentiometer. Only the mounting
More information60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay
Series - General purpose relays - 0 A Features Plug-in mount 0 A General purpose relay.. & pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listed (certain relay/socket
More informationPrecision Junction Boxes
Precision Junction Boxes Accuracy and Stability All components are designed for high accuracy and long term stability. Precision SMT resistors and gold plated switches guarantee trouble free operation.
More informationElectronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet
2CDC 251 121 F0004 1 5 2 4 3 6 Characteristics Single-function impulse-off timer One device includes 10 time ranges, from 0.05 s to 300 h, for the adjustment of the pulse time Remote potentiometer connection
More informationRemote I/O. 74 Remote I/O. Remote I/O System
System Overview of the System Components IS1+ 76 General Information IS1+ 77 CPU & Power Modules CPU & Power Modules for Zone 1 / Div. 1 IS1+ 9440/22 78 Sockets for CPU & Power Module IS1+ 9490 78 CPU
More informationAngular position transmitter OPF
Angular position transmitter OPF Date: February 2012 Sheet No.: 6-300 GB OPF angle transmitter ATEX approved, Zone 0 IECex approved, Zone 0 Vibration resistant Span and Zero adjustment Long service life
More information5069 Compact I/O Modules Specifications
Technical Data 5069 Compact I/O Modules Specifications Digital I/O Module Catalog Numbers 5069-IB16, 5069-IB16F, 5069-IB6F-3W, 5069-OB16, 5069-OB16F, 5069-OW4I, 5069-OX4I Analog I/O Module Catalog Numbers
More information9mm Size Metal Shaft Snap-in Type. Single-unit and dual-unit types suit a variety of controls. Typical Specifications. Total resistance tolerance ±20%
K09L 9mm Size Snap-in Single-unit and dual-unit s suit a variety of controls Typical Specifications Items Specifications tolerance ±% Maximum operating voltage V AC, V DC Total rotational angle 300 ± otational
More informationEmergency lighting units EM powerled
CPS FX SR 50 W ED Driver for AC and DC power supplies Product description Independent fixed output ED Driver for mains operation with integrated Simple CORRIDOR FUCTIO (CF) Emergency lighting function
More informationSignal conditioner - MACX MCR-UI-UI-NC
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid
More informationTechnical Data. General specifications. Rated operating distance s n 3 mm
0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up
More informationPHASED OUT. LED Driver Compact fixed output. Driver LCI 20W 350mA 900mA TOP C TOP series
EL Product description Fixed output built-in LED Driver Constant current LED Driver Output current settable 30 900 ma Max. output power 20 W Nominal life-time up to 100,000 h For luminaires of protection
More informationHigh-current terminal block - UKH
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid
More informationPHASED OUT. LED Driver Compact fixed output. Driver LCI 10W 150mA 400mA TOP C TOP series. Product description
Product description EL Fixed output built-in LED Driver Constant current LED Driver Output current settable 15 4 ma Max. output power W Nominal life-time up to, h For luminaires of protection class I and
More informationInsulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC
Data sheet Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC The CM-IWS.1 serves to monitor insulation resistance in accordance with IEC
More informationLED Driver Linear / area fixed output
Driver LC 53W 5-35mA flexc lp ANCED series Product description Built-in constant current LED Driver New version DC operating with EL marking Adjustable output current between 5 and 35 ma Max. output power
More informationSafety switches with slotted hole lever
Safety switches with slotted hole lever Selection diagram C1 C C C4 C5 Straight slotted hole lever Slotted hole lever at the left Slotted hole lever at the right (without bend) Slotted hole lever at the
More informationPrecision Junction Boxes
Precision Junction Boxes Accuracy and Stability All components are designed for high accuracy and long term stability. Precision SMT resistors and gold plated switches guarantee trouble free operation.
More informationElectronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet
CDC 0 F0t07 Features Rated control supply voltage -8 V DC, -0 V AC Single-function timer with star-delta change-over One device includes 7 time ranges (0.0 s - 0 min) n/o contacts LEDs for status indication
More informationRelays & Sockets RY/RM RY/RM Series Miniature Relays. Part Number Selection
RY/RM Series Miniature Relays Key features: RY (A), RY (A), RM (A) General purpose miniature relays A or A contact capacity Wide variety of terminal styles and coil voltages meet a wide range of applications
More informationElectronic timer CT-TGD.22
2CDC 251 097 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection
More informationPHASED OUT. LED Driver Compact fixed output. Driver LCI 10W 350mA 900mA TOP C TOP series
EL Product description Fixed output built-in LED Driver Constant current LED Driver Output current settable 35 9 ma Max. output power W Nominal life-time up to, h For luminaires of protection class I and
More informationLow profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b
Low profile safety relay with forcibly guided double contacts SFN4D RELAY 3.3 33.0 FEATURES Relay complies with EN 020, Type B. Polarized magnet system with snap action function Tolerance ±0.3 mm Weight
More informationRemote controllable and available in a wide variety of products. Typical Specifications. Total resistance tolerance ±20% Maximum operating voltage
RK168 Motor-driven Remote controllable and available in a wide variety of products Typical Specifications Items Specifications tolerance ±0% Maximum operating voltage 50V AC Total rotational angle 0 ±5
More informationFully Sealed Container Cermet Potentiometer Professional Grade
Fully Sealed Container Cermet Potentiometer Professional Grade T Q O QUICK REFERENCE DATA Multiple module Switch module Detent module Special electrical laws No n/a n/a A: linear, L: logarithmic, F: reverse
More informationPassive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)
Passive Current Transducers for Sinusoidal Alternate Currents From 0... A/0...5 A (-SW) Passive current transducer without power supply Measuring range A and 5 A AC, reconnectable Available with threshold
More information22/10/2012
83139 Standard 831390 Part number IP 67 protection against hydrocarbons, detergents Double break switching Double insulated or Atex flameproof casing Choice of actuators Part numbers Type Function 83139003
More informationServomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16
MZ Servomotor for butterfly valves VF, VFH delta-elektrogas.com EE157-01/16 MZ Servomotor Contents Description.... 2 Features........ 2 Functioning and application..... 3 Technical specifications......
More informationMeasuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC
2CDC 251 244 F0t05 Characteristics Monitoring of DC and AC currents: RMS measuring principle One device includes 3 measuring ranges Over- or undercurrent monitoring configurable Hysteresis adjustable from
More informationType: DILEM 10 G(24VDC) Article No.:
Type: DILEM 10 G(24VDC) Article No.: 010213 Ordering information Description Connection technique Rated operational current AC 3 380 V 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 220
More informationInsulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 V AC
Data sheet Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 AC The CM-IWS.2 serves to monitor insulation resistance in accordance with IEC 61557-8 in unearthed IT AC systems
More informationModel Number Structure
General-purpose Relay MK-I/-S Electromechanical Relays Exceptionally Reliable General-purpose Relay Features Mechanical Indicator/Push Button Breaks relatively large load currents despite small size. Long
More informationSINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar
For electrically insulating, amplifying and converting DC signals 0102 II (1) G Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. 1 and 2) is to electrically insulate input and output
More informationPower Supplies 3. SDN-C Compact DIN Rail Series
SDN-C Compact DIN Rail Series The SDN-C DIN rail power supplies are the next generation of the popular SDN series. These models combine high efficiency and compact size with new visual diagnostic LEDs
More informationMODEL: KS. Plug-in Signal Conditioners K-UNIT
Plug-in Signal Conditioners K-UNIT DC ALARM Functions & Features Providing relay contact closures at preset DC input levels Dual (Hi/Lo) trip Multi-turn screwdriver setpoint adjustments Monitor jacks provided
More informationMINI-PS AC/24DC/1.3
Power supply unit INTERFACE Data sheet 102894_en_03 1 Description PHOENIX CONTACT 2015-11-17 Features MINI POWER power supplies for MCR technology In measurement and control technology (MCR), modular electronics
More informationOMRON MK-I / -S RELAY
Issued April 0 0 DATA SHEET OMRON MK-I / -S RELAY Based on OMRON Datasheet General-purpose Relay MK-I/-S 0 Exceptionally Reliable General-purpose Relay Features Mechanical Indicator/Push Button Breaks
More information3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching
Main Characteristics: Zero-point switching LED display Various connection technologies Plug-in control terminal Degree of protection IP 2 Insulated mounting foot Standards / Approvals: DIN EN 697--3 UL
More informationGeneral data. 13/20 Siemens IC Overview Front plate mounting
General data Overview Front plate mounting D C B E A F D NSD0_00029b B C A A B C D E F Actuator Front plate Holder Contact block Lampholder Support element For actuators see page /25 to /62. For contact
More informationMODEL: 47LV. Digital Panel Meters 47 Series
Digital Panel Meters 7 Series DC INPUT DIGITAL PANEL METER ( ½ digit, LED display type) Functions & Features ½ digit DC input digital panel meter /8 DIN size Moving average function to suppress the display
More informationType CP-S, CP-C & CP-A Switch mode
Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting
More informationLED control gear Compact dimming. Uconverter LCBI 10 W 180/350/500 ma phase-cut/1 10 V lp BASIC series
Uconverter CBI W 1/3/ ma phase-cut/1 V lp BASIC series Product description Dimmable built-in ED Driver Constant current Output current 1, 3 or ma Max. output power W ominal life-time up to, h SEV Dimmable
More informationHMI Components. Series. Raised design PCB (with adaptor) Machinery and Automation. Indicator Illuminated pushbutton
Edition 10/2016 HMI Components 41 Series Characteristics The rectangular design of the Series 41 (18 x 24 mm) makes it especially suited: Raised design PCB (with adaptor) Functions The Series 41 incorporates
More informationA wide range of versatile products applicable for various types of control. Typical Specifications. Total resistance tolerance ±20%
RK63 6mm Size A wide range of versatile products applicable for various types of control Typical Specifications Items Specifications tolerance ±% Maximum operating voltage V AC, V DC Total rotational angle
More informationP5201 Universal Programmable Transmitters with Galvanic Isolation
Transmitters - KB0288-2012/09 P5201 Universal Programmable Transmitters with Galvanic Isolation One type of transmitter for all regular resistance and thermocouple sensors. Linearized output signal 4 to
More informationMotor Protection Circuit Breaker Series 8146/5-V27
www.stahl.de > For protection of Ex e and Ex d motors > Protects electric lines and plant equipment > Thermal overcurrent release, adjustable, phase failure sensitive > Electromagnetic quick release >
More informationControl module CP-A CM
2CDC 271 002 F0t05 Features Pluggable onto redundancy unit CP A RU Threshold values adjustable (14 28 V) One relay output per monitored input / channel Approvals H UL 508, CAN/CSA C22.2 No.14 H UL 60950,
More informationPHOENIX CONTACT - 09/2009
Electronic miniature circuit-breaker CLIPLINE Data sheet 03906_en_0 PHOENIX CONTACT - 09/2009 Description The EC-E... electronic miniature circuit-breaker selectively protects all 24 V DC load circuits
More informationSDN-C Single and three phase power supplies Product Guide
SDN-C Single and three phase power supplies Product Guide Compact PERFORMANCE DIN RAIL Series Our next-generation SDN-C power supplies offer high efficiency in a compact size, providing up to 960 Watts
More information1-1. Kirchoff s Laws A. Construct the circuit shown below. R 1 =1 kω. = 2.7 kω R 3 R 2 5 V
Physics 310 Lab 1: DC Circuits Equipment: Digital Multimeter, 5V Supply, Breadboard, two 1 kω, 2.7 kω, 5.1 kω, 10 kω, two, Decade Resistor Box, potentiometer, 10 kω Thermistor, Multimeter Owner s Manual
More informationInstructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.
Delivery program Contactor relay, 2N/O+2N/C, DC current Part no. DILER-22-G(24VDC) Catalog No. 010042 Eaton Catalog No. XTRM10A22TD EL-Nummer 4130354 (Norway) Product range DILER Mini-contactors Application
More informationCurrent monitoring relays CM-SRS.2 for single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.2 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
More informationLED Driver Compact fixed output
w LED Driver Driver LCI 100W 900mA 1750mA TOP C TOP series Product description Fixed output built-in LED Driver Constant current LED Driver Output current settable 900 1,750 ma Max. output power 100 W
More information650 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN
650 PHOENIX CONTACT Monitoring relays, timer relays, function blocks The requirements pertaining to safety and system availability are constantly increasing regardless of the industry. Processes are becoming
More informationM224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #
Solenoid coil MKY/18x60 For explosion-hazard zones Protection class IP65/66/67 Optional with integrated amplifier electronics Ex db IIC T6 / T4 Gb Ex tb IIIC IP65 T80 C/T130 C Db Ex db I Mb II 2 G Ex db
More informationSINEAX B 811 Power Pack with additional Functions
SINEA B 8 for intelligent and conventional s, in housing S7 for rail and wall mounting 002 II () G Application The power supply unit SINEA B 8 (Figure ) provides the DC power supply for s and transfers
More information58 SERIES. Relay interface modules 7-10 A 58.P3 58.P4
58 58 3 & 4 CO relay interface modules, 31 mm wide with Push-in terminals Ideal interface for PLC and electronic systems 58.P3 58.P4 Type 58.P3 3 CO 10 A Push-in terminals Type 58.P4 4 CO 7 A Push-in terminals
More information