TSC 401 Torque/Speed Conditioner
|
|
- Maria Mills
- 6 years ago
- Views:
Transcription
1 TSC 0 Torque/Speed Conditioner.0 Connection Speed Cable Torque Cable (dynamometer loadcell) MAGTROL SA SWITZERLAND TORQUE SPEED CONDITIONER Type : TSC 0 P/N : S/N : Kit x matched with xwbxxx / xpbxxx S/N: xxxx Cable TSC0-DSP600 P/N XX (XX: version according to cable length) (-pin plug) J Connector Figure. TSC 0 Connection. Cables WB / PB Torque Cable KIT TSC0 + Cable Dynamometer Model (dyno load cell) Speed Cable.7 ; ; ;
2 User s Manual Magtrol TSC 0 Torque/Speed Conditioner. External Connector Not conected (blk). N/A. + VDC (yel). ± VDC COM (yel/blk) (analog common). ± VDC COM (yel/blk) (analog common) 6. - VDC (gy) 7. + VDC () VDC COM (digital common) 9. N/A 0. TACH. A (TTL square wave signal 0- V). N/A. N/A. TORQUE COMMON (grn). TORQUE SIGNAL () Figure. J -pin Connector. Internal Connectors (on TSC 0 board) grn blk J Ex - Ex + IN - IN + Shield Figure. J Torque Connector (for Connection of Load Cell) J 0 VD Signal + VD Figure. J 60-bit Speed Connector J 0 VD Signal + VD Figure. J 600x-bit Speed Connector Speed (RI-8)
3 Magtrol TSC 0 Torque/Speed Conditioner User s Manual.0 Configuration - Solder Links In the table below, the notation for instance 7 means that all the solder links from through 7 are to be done. Dynamometer Model Nominal Torque Loadcell Sensitivity (mv/v) Signal Provided by the Load Cell (mv) [sensitivity power supply (~ 0 VDC)] Links to be Solde WB.7-8-K 0 mnm WB.7-8-K 00 mnm WB.7-8-K 0 mnm WB.7-8-K 600 mnm PB.7-8-K 600 mnm PB.7-8-K. Nm PB.7-8-K. Nm WB. Nm WB Nm PB Nm. 0. PB -S Nm PB 0 Nm. 0. WB 6 0 Nm WB 6-F 0 Nm WB 6 0 Nm WB 6-F 0 Nm PB 6 Nm PB 6 0 Nm PB 6-S 0 Nm PB 6-G 0 Nm WB 0 Nm WB 00 Nm PB 00 Nm PB -G 00 Nm PB 00 Nm WB 0 Nm WB 80 Nm. 0. WB 0 Nm WB 60 Nm PB 00 Nm PB 600 Nm. 0.0 PB 00 Nm. 0.0 The values of tension of the cell can vary according to the mechanical and electrical tolerances. It is acceptable that solder links vary from ± position with regard to the table above. If the dynamometer is not fitted with a standard Magtrol Load Cell, solder links have to be configu as per comparable load cell sensitivity in the above table. When delive from the factory with a dynamometer, the TSC 0 will be configu and matched with the dynamometer prior to delivery and labeled accordingly.
4 User s Manual Magtrol TSC 0 Torque/Speed Conditioner.0 Calibration - TSC 0 with dynamometer Internal groove for use of gauged weight in Newton [N] External groove for use of gauged weight in kilograms [kg] Figure 6. WB/PB Dynamometer with Calibration Arm. Make sure that the solder link configuration is completed according to the table in Section.0.. Connect the TSC 0 to the dynamometer and to the DSP7000 controller.. Mount both sides of the calibration arm according to Figure 6.. Connect a voltmeter (multimeter # ) between TP ( + ) and TP ( - ). Signal provided by the TSC 0: 0± VDC. Connect a voltmeter (multimeter # ) between terminals (IN-) and (IN+ ) of connector J. Signal provided by the load cell is according to the table in Section.0 Configuration - Solder Links. 6. Switch ON the DSP Configure the DSP7000 as follows: Display Unit = Nm Scale Factor = According to specifications of the dynamometer to be calibrated. 8. Adjust ZERO potentiometer until it reads 0 VDC (± mv) (multimeter # ). Signal provided by the load cell should be: 0 mv (multimeter # ) 9. Apply 00% of the nominal load on the positive side. 0. Check if the adjustment is possible from.7 VDC up to. VDC with CW. If.7 VDC cannot be reached because it is not possible to decrease the signal to that value, one solder link should be removed. On the contrary, if.7 VDC cannot be reached by increasing the signal, one solder link should be added.. Adjust CW until it reads (#) VDC (± mv) (multimeter # ). Signal provided by the load cell should be according to the table in Section.0 (multimeter # ). Set the overload nut in order to make the signal decrease (+.9 VDC). Apply 00% of the nominal load and set the overload nut to + 7. VDC (± 00 mv) (multimeter # ).
5 Magtrol TSC 0 Torque/Speed Conditioner User s Manual. Unload to 00% and check if it still reads VDC (± mv) (multimeter # ).. Unload completely. The signal should be 0 VDC (± 0 mv) (multimeter # ).. Apply 00% of the nominal load on the negative side. 6. Adjust CCW until it reads (#) VDC (± mv). Signal provided by the load cell should be according to the table in Section.0 (multimeter # ). 7. Set the overload nut in order to make the signal decrease (-.9 VDC ) 8. Apply 00% of the nominal value and set the overload nut to - 7. V (± 00 mv). 9. Unload to 00% and check if it still reads V (± mv). 0. Unload completely. It should read 0 V (± 0 mv). If the system does not include a DSP7000 Dynamometer Controller, connect the TSC 0 to the Power Supply according to the J connector pin set up (see Figure 7) and follow the above calibration procedure FOR TORQUE MEASURE. + VDC (yel). ± VDC COM (yel/blk) (analog common). ± VDC COM (yel/blk) (analog common) 6. - VDC (gy) FOR SPEED MEASURE 7. + VDC () VDC COM (digital common) Figure 7. J Connector for Calibration REVISION HISTORY Date Edition Change 07/00 First Edition, revision A New layout - no change in content 09/000 First Edition Original manual Testing, Measurement and Control of Torque-Speed-Power Load-Force-Weight Tension Displacement Magtrol Inc 70 Gardenville Parkway Buffalo, New York USA Phone: Fax: magtrol@magtrol.com Magtrol SA Route de Montena Rossens / Fribourg, Switzerland Phone: + (0) Fax: + (0) magtrol@magtrol.ch Subsidiaries in: Great Britain Germany France China India Worldwide Network of Sales Agents
MAGTROL. KLB Wedge socket. KLB/KLE/KLU Data Sheet SYSTEM CONFIGURATION
Data Sheet KLB Wedge socket Features Mechanical system suitable for measuring for measuring forces between 20 and 160 kn Specially designed for lifting applications in fixed point High reliability for
More informationMAGTROL. LMU Series Load Monitoring Units. LMU Data Sheet. Description. Features
MAGTROL Data Sheet Series Load Monitoring Units Features For use with full-bridge strain gauge transducers (sensitivity 0.5 to 4 mv/v) Voltage input for load summation or for individual use (without sensor)
More informationMAGTROL. LMU 112 and LMU 117 Load Monitoring Units. LMU 112 / LMU 117 Data Sheet LMU 112 FEATURES LMU 117 FEATURES DESCRIPTION SYSTEM CONFIGURATION
Data Sheet LMU 112 and LMU 117 Load Monitoring Units LMU 112 FEATURES For Use with Full-bridge Strain Gauge Transducers (Sensitivity 0.5 to 2 mv/v) Voltage Input for Different Charge Summation 2 Level
More informationMAGTROL. LMU 116 Load Monitoring Unit. LMU 116 Data Sheet FEATURES DESCRIPTION SYSTEM CONFIGURATION
Data Sheet Load Monitoring Unit FEATURES For Use with Full-bridge Strain Gauge Transducers (Sensitivity 0.5 to 2 mv/v) Voltage Input for Different Charge Summation Summer with 4 Inputs Taring Facility
More informationLOAD MEASURING PINS LE-LU SERIES FEATURES DESCRIPTION APPLICATIONS
LE-LU SERIES LOAD MEASURING PINS Magtrol offers a wide range of Load-Force-Weight Transducers with optional integrated electronics or Load Monitoring Units (LMU) with B.I.T.E. functions creating an ideal
More informationSIGNAL CONVERTER I/V AND I/I CST 113
INSTRUCTION MANUAL SIGNAL CONVERTER I/V AND I/I P/N 623.005 E ( MACST113-01/E ) Copyright Magtrol SA, 1997 All rights reserved Published and printed by Magtrol SA in Fribourg, Switzerland The information
More informationMAGTROL. DI Series Displacement Transducers. DI Data Sheet. Features
ata Sheet Series isplacement Transducers Features Large measuring range: Piston displacements from 50 to 1000 mm; 80 to 250 mm for 63X models urrent-based output signal (4 to 20 ma) for displacement uilt-in
More informationCSG110 Strain Gauge Universal Amplifier
Quick Start Guide CSG110 Strain Gauge Universal Amplifier Sensor Solutions Source Load Torque Pressure Multi-Axis Calibration Instruments Software www.futek.com Getting Help TECHNICAL SUPPORT For more
More informationTECHNICAL MANUAL. SERIES AP5103 DIN-Rail DC Strain Gage Conditioner ISO 9001/AS9100
TECHNICAL MANUAL SERIES AP5103 DIN-Rail DC Strain Gage Conditioner ISO 9001/AS9100 Due to the nature of technology, changes are inevitable. For latest technical specifications, see our website. Copyright
More informationLoad Monitoring Units. LMU 212 and LMU 217. User s manual
Load Monitoring Units LMU 212 and LMU 217 User s manual While every precaution has been exercised in the compilation of this document to ensure the accuracy of its contents, Magtrol assumes no responsibility
More informationUSER MANUAL. Integration Kit BKIT MCINT BKIT MCIHT. Integration Kit for: Maxwell Technologies Ultracapacitor Cells
USER MANUAL Integration Kit BKIT MCINT BKIT MCIHT Integration Kit for: Maxwell Technologies Ultracapacitor Cells 2013 Maxwell Technologies, Inc. 1011158.5 1. Introduction This integration kit is intended
More informationLB-LE-LU SERIES USER GUIDE LOAD MEASURING PINS.
LB-LE-LU SERIES LOAD MEASURING PINS USER GUIDE 01 LB-LE-LU series While every precaution has been exercised in the compilation of this document to ensure the accuracy of its contents, Magtrol assumes no
More informationCatalog of CLA force and torque sensors
Catalog of CLA force and torque sensors SC-002 LC-01 LC-10 TSF-000 TSF-05 TSF-1 TSF-100 Micro-force sensor Force sensor Micro-torque sensor Torque sensor Phone +41 32 421 44 90, Fax +41 32 421 44 91, ventes@cla.ch,
More informationLoad Monitoring Unit LMU 216. User s manual
Load Monitoring Unit LMU 216 User s manual While every precaution has been exercised in the compilation of this document to ensure the accuracy of its contents, Magtrol assumes no responsibility for errors
More informationTorque Sensor Series 3000 and Series 4000
Properties Sensorshaft with integrated torque and angle measurement Non-contact measurement system, high robustness Plug & Play solution, no additional electronics required Performance Measurement range
More informationTechnical data. Your advantages
Technical data Nominal torque: 50 Nm to 2.000 Nm, bidirectional Rotational speed: 10.000 rpm Accuracy: ±0,2 % Temperature range: -40 C to +85 C Protection class: IP50, IP65 Output signals: 0-10 V/4-20
More informationEmbedded Strain Gauge and Load Cell Signal Conditioner/Amplifier v.2.3
Embedded Strain Gauge and Load Cell Signal Conditioner/Amplifier v.2.3 1 DESCRIPTION The EMBSGB200 v.2.3 embedded strain gauge signal conditioner is a versatile, low cost solution to your strain measurement
More informationSeries 7000 Torque Sensor for PTO-shafts
Properties PTO (Power Take-Off) shaft with integrated torque and angle measurement Non-contact measurement system, high robustness Special for PTO shafts 1 ¾ und 1 3/8 Plug & Play solution, no additional
More information12/4/ X3 Bridge Amplifier. Resistive bridge amplifier with integrated excitation and power conditioning. Logos Electromechanical
12/4/2010 1X3 Bridge Amplifier Resistive bridge amplifier with integrated excitation and power conditioning. Logos Electromechanical 1X3 Bridge Amplifier Resistive bridge amplifier with integrated excitation
More informationRENATO DESIRÒ PARABIAGO (MI) Via Sant Anna, 51 Tel Fax
A1T ANALOG AMPLIFIER (for load cells on sensor roll) USER MANUAL RENATO DESIRÒ PARABIAGO (MI) Via Sant Anna, 51 Tel. 0331-491452 Fax 0331-493591 Page 1 SPECIFICATIONS POWER SUPPLY Form 20 Vdc to 28 Vdc
More informationModel 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R
O P E R AT I O N M A N U A L Model 4800 L O A D C E L L S U M M I N G T R A N S M I T T E R CALEX Manufacturing Company, Inc. Concord, California 94520 Ph: 925/687-4411 800/542-3355 Fax: 925/687-3333 http://www.calex.com
More informationModel LIA100. Lock-in Amplifier
Model LIA100 Lock-in Amplifier Operations Manual Thorlabs, Inc 435 Route 206 Newton, NJ 07860 P-(973) 579-7227 F-(973) 300-3600 www.thorlabs.com Doc. Page 1 of 10 Table of Contents Chapter Description
More informationData Sheet for Angle Sensors
ETA25PM - R ETA25PM - F ETA25PM - TS 10 to 100-times longer life compared with multiturn potentiometers Free user programmable start and end position (electrical angle 10 up to 72000 ) Simple user programming
More informationUSER MANUAL. Maxwell Technologies. Integration Kit. Models: BKIT MCINT BKIT MCIHT.
USER MANUAL Maxwell Technologies Models: BKIT MCINT BKIT MCIHT Maxwell Technologies, Inc. Global Headquarters 3888 Calle Fortunada San Diego, CA 92123 USA Phone: +1 (858) 503-3300 Fax: +1 (858) 503-3301
More informationWS12EX Position Sensor with Analog output Dust explosion-proof
Sensor for Hostile Environments Class IP67 Measurement Range: 0... 100 mm to 0... 3000 mm With Analog Output Dust Ex proof, category 3, zone 22 II 3D EEx T80 C IP67 Specifications Outputs Material Resolution
More informationWorldwide Manufacturer of Gas Detection Solutions. Transmitter EC 23. Operation Manual
Worldwide Manufacturer of Gas Detection Solutions Transmitter EC 23 Operation Manual Table of Contents For Your Safety...4 General Description...4 Electrical Connections...5 Zero Point Adjustment...5
More informationMAGTROL. KLB Wedge socket. KLB/KLE/KLU Data Sheet SYSTEM CONFIGURATION
Data Sheet KLB Wedge socket Features Mechanical system suitable for measuring for measuring forces between 20 and 160 kn Specially designed for lifting applications in fixed point High reliability for
More informationIncremental encoders With blind or through hollow shaft pulses per revolution programmable
Features Size ø58 mm Precise optical sensing Output signal level programmable (TTL or HTL) Blind or through hollow shaft, ø8 15 mm Connection axial, radial or tangential Pulses per revolution 1...65536,
More informationLAB #5: Measurement of Strain
LAB #5: Measurement of Strain Equipment: Multimeter & DC Power Supply Balance Unit & Calibration Resistor Strain Indicator (Measurements Group, Model P-3500) Aluminum (Cantilever) Beam with Two Gages Aluminum
More informationTorque Sensor Accessories and Services
------------------- Torque Sensor Accessories and Services Highlights Strain gage signal conditioners Cable assemblies Speed sensors Shunt calibration modules and thermocouples Calibration services PCB
More informationPRODUCT SPECIFICATIONS
FEATURES AND BENEFITS* Up to 1,000,000 duty cycles or 10 year DC life 51V DC working voltage Active cell balancing Temperature output Overvoltage outputs available High power density Extreme Vibration
More informationProgrammable Attenuators
Model 3200 Series Programmable Attenuators with optional TTL Interface dc to 3.0 GHz 1 Watt CELL CONFIGURATIONS: Features o Widest Selection of Attenuation Ranges & Step Sizes o Available Express Models:
More informationPRODUCT SPECIFICATIONS
FEATURES AND BENEFITS* Up to 1,000,000 duty cycles or 10 year DC life 48V DC working voltage Active cell balancing Temperature output Overvoltage outputs available High power density Extreme Vibration
More informationLP SERIES MODEL LP35 LOW PROFILE INCREMENTAL OR ABSOLUTE ENCODER
LP SERIES MODEL LP35 LOW PROFILE INCREMENTAL OR ABSOLUTE ENCODER Features Low profile package saves space Excellent resistance to shock and vibration 30mm standard through shaft, PEEK reduction hub available
More informationTorque Sensor. Torque. with Dual-Range-Option. Type 4503A...
Torque Torque Sensor with Dual-Range-Option Type 4503A... Type 4503A... torque sensors with built-in speed sensor operate on the strain gage principle. An integral, digital measurement conditioning system
More informationDST-2000C. Direction Sensing Tachometer INSTRUCTION MANUAL
DST-2000C Direction Sensing Tachometer INSTRUCTION MANUAL Azonix-Dynalco, 3690 N. W. 53 Street, Ft. Lauderdale, FL 33309 U.S.A.! (954) 739-4300 Fax (954) 484-3376 www.dynalco.com mailbox@dynalco.com October
More information3 CHANNEL LOAD CELL SIGNAL CONDITIONER. Owner's Manual
3 CHANNEL LOAD CELL SIGNAL CONDITIONER Owner's Manual Boeing Helicopters Part Number 414ES230-SIG CON-1 Breeze-Eastern Part Number Y-1368-1 Onboard Systems Part Number 210-115-00 Manual Number 120-042-00
More informationDA 22 Technical Specification
1/26 DA 22 DA 22-12-2615 DA 22-12-4112 DA 22-30-2630 DA 22-30-4128 2/26 Content 1. General Description... 3 2. Operating Data... 4 2.1. Operating Data 12V-Versions... 4 2.2. Operating Data 28V-Versions...
More informationDR3535 DR3535-O. Hardware Reference Manual. Document Revision A7 May 16, 2018 MICROKINETICS CORPORATION
-O Hardware Reference Manual Document Revision A7 May 16, 2018 MICROKINETICS CORPORATION 3380 Town Point Drive Suite 330 Kennesaw, GA 30144 Tel: (770) 422-7845 Fax: (770) 422-7854 www.microkinetics.com
More informationSE 120. Piezoresistive accelerometer
Piezoresistive accelerometer FEATURES» From the Vibro-Meter product line» High-sensitivity accelerometer» Low-frequency vibration monitoring» Suitable for hydraulic turbine applications» Integral cable»
More informationPSI Temperature Scanners
Networkable Voltage & Temperature Instruments Withstand 30 g and 160 db Smart Connector with Auto Sensor Discovery NetScanner Compatible DESCRIPTION The PSI 9146 and 9046-S are networkable instruments
More informationABSOLUTE MULTI-TURN ENCODER HMT25
ABSOLUTE MULTI-TURN ENCODER HMT25 Introduction The HMT25 geared multi-turn encoder provides absolute position information over multiple turns of the input shaft. It keeps track of the exact position even
More informationLoad cell system fault finding guide (Application Note: Number AN1)
Load cell system fault finding guide (Application Note: Number AN1) Table of Contents Basic checks 3 Basic load cell system............................ 3 Basic load cell resistance checks......................
More information3DM phase Digital Stepper Drive
3DM2283 3-phase Digital Stepper Drive 150-220VAC, 0.5-8.2A peak, Auto-configuration, Low Noise Anti-Resonance provides optimal torque and nulls mid-range instability Motor auto-identification and parameter
More informationXXXX e. X d.. X X X a
The Heavy uty incremental encoder type 0H boasts a high degree of ruggedness in a very compact design. Its special construction makes it perfect for all applications in very harsh environments. / RoHS
More informationDSTS-5A/2C User's Manual
ELECTRONIC DEVICES INC. P.O. BOX 15037, CHESAPEAKE, VA 23328. PH 757-421-2968 FAX 421-0518 DSTS-5A/2C User's Manual 1. PACKING LIST 2. OVERVIEW 3. CONNECTING THE DSTS-5A/2C TO A COMPUTER 4. CONNECTING
More informationExercise 2: FM Detection With a PLL
Phase-Locked Loop Analog Communications Exercise 2: FM Detection With a PLL EXERCISE OBJECTIVE When you have completed this exercise, you will be able to explain how the phase detector s input frequencies
More informationOP5000 Signal Conditioning & I/O Products for RT-LAB Engineering Simulators OP5511 High-current and high-voltage input conditioning module
OP000 Signal Conditioning & I/O Products for RTLAB Engineering Simulators OP11 Highcurrent and highvoltage input conditioning module User Manual Published by OpalRT Technologies, Inc. 11 Richardson, suite
More informationIncremental encoders With blind or through hollow shaft pulses per revolution programmable
Features Size mm Precise optical sensing Output signal level programmable (TTL or HTL) Blind or through hollow shaft, ø8 15 mm Connection axial, radial or tangential Pulses per revolution 1...65536, programmable
More information5-pole M12 connector. Connecting cable: cab-m12/5-g-2m. LED (red) for dirt accumulation indication
D-LAS Series D-LAS-34-ED-25x2-AC-T (Glass Pane Detection) - Collimated laser beam (
More informationUSER MANUAL. Maxwell Technologies Ultracapacitor Energy Storage Modules. Models: BMOD0058 E016 B02 BMOD0006 E160 B02. Document
USER MANUAL Maxwell Technologies Ultracapacitor Energy Storage Modules Models: BMOD0058 E016 B02 BMOD0006 E160 B02 Document 3000200.1 Notice: The products described herein are covered by one or more of
More informationOPERATION MANUAL LDM-1000
OPERATION MANUAL LDM-1000 TE CONNECTIVITY SENSORS /// LDM-1000 OPERATION MANUAL P/N 09290100-000 REV. C 05/2016 Page 1 Table of Contents 1. Introduction...3 2. Product Specifications...3 3. Product Description...4
More informationCOMPACT 700 SERIES ENCODERS FOR DRIVES
COMPACT 700 SERIES ENCODERS FOR DRIVES Robustness in tight spaces An encoder is mounted at the rear of a motor and therefore affects the motor s overall length. In tight spaces, the build length can be
More informationInstallation, Operation and Maintenance Manual
TM M723 Rev. C Model 1050 Strain Gage Transmitter Installation, Operation and Maintenance Manual Table of Contents General... 1 Installation... 1 Specifications... 1 Wiring... 2 Setup and Operation...
More informationDatasheet of the MEZ Stepper Servo Drive MEZ 2D VDC, 8.2A Peak, Closed-loop, No Tuning. Version
Datasheet of the MEZ Stepper Servo Drive MEZ D880 4-75VDC, 8.A Peak, Closed-loop, No Tuning Version 0.1.1 http://www.motionking.com Features Step and direction control Closed position loop for no loss
More informationXXXX e. X d.. X X X a
The Heavy Duty incremental encoder type 0H boasts a high degree of ruggedness in a very compact design. Its special construction makes it perfect for all applications in very harsh environments. / RoHS
More informationOperating Manual Fast Modulator FM 10-50
Document: 10100312 Revision: 000 Date: 20.01.2016 Page 1/14 Warning! Risk of exposure of hazardous laser radiation in combination with laser light emitting devices! Revision 000 Created Approved Released
More informationNon-Spring Return DuraDrive Modulating Actuator
MS41-60xx Series n-spring Return DuraDrive Modulating Actuator The DuraDrive direct coupled 24 Vac non-spring return rotary electric actuators are designed for modulating control of dampers. S41-60xx ries
More informationSeismometer Preamplifier Manual
Seismometer Preamplifier Manual Seismometer Preamplifier Manual Part number Revision Date Description 13867 1.0 2001-12-18 Initial release Seismometer Preamplifier - Table of Contents 1 Introduction...
More informationDA 20 Technical Specification
1/18 DA 2 DA 2-6-255 DA 2-12-2515 DA 2-3-253 2/18 Content 1. General Description... 3 2. Operating Data... 4 2.1. Operating Data 6V-Versions... 4 2.2. Operating Data 12V-Version... 5 2.3. Operating Data
More informationDA DA 10 Technical Specification. Page 1/14. Volz Servos GmbH & Co. KG servos.com
1/14 DA 10 DA 10 05 42 2/14 Content 1. General Description... 3 2. Operating Data... 4 3. Performance... 5 4. Command Signal... 6 5. Materials and Protective Features... 7 6. Dimensions... 7 6.1. Installation
More informationIOM. Model 1050 Strain Gage Transmitter Installation & Operation Manual. (Cage Code #1MU21)
IOM Model 1050 Strain Gage Transmitter Installation & Operation Manual (Cage Code #1MU21) Model 1050 Strain Gage Transmitter Installation & Operation Manual CONTENTS I. GENERAL...1 II. INSTALLATION...2
More informationTorque Sensor. Torque. Dual-Range Sensor with Brushless Transmission. Type 4503A...
Torque Torque Sensor Dual-Range Sensor with Brushless Transmission Type 4503A... Type 4503A... torque sensors with built-in speed sensor operate on the strain gage principle. An integral, digital measurement
More information500mA Laser Diode Controller
IP500 500mA Laser Diode Controller Operating Manual THORLABS, Inc. Ph: (973) 579-7227 435 Route 206N Fax: (973) 300-3600 Newton, NJ 07860 USA www.thorlabs.com Table of Contents TABLE OF FIGURES 1 OVERVIEW
More information3-AXIS INCLINE SENSORS (IP69K)
DINC General Specifications / Order Guide Inclinometers ; DINC / 1 of 5 Joral REF S4; I3 / 1 DINC Boom Angle Sensor 3 axis inclinometer, dual module Two inclinometers which report master and slave position
More informationDatasheet of the Easy Servo Drive ES-D VAC or VDC, 8.2A Peak, Close-loop, No Tuning. Version
Datasheet of the Easy Servo Drive ES-D1008 0-70 V or 30-100VDC, 8.A Peak, Close-loop, No Tuning Version 0.1.0 http://www.leadshine.com Features Step and direction control Closed position loop for no loss
More informationKistler LabAmp for DynoWare
Electronics & Software Kistler LabAmp for DynoWare Charge Amplifier and Data Acquisition for Multicomponent Force Measurement This instrument is ideal for multicomponent force-torque measurement with piezoelectric
More informationMiniature pressure sensor
SPECIFICATIONS Ranges 0.5 to 350 bar [7 psi to 5 000 psi] Absolute, sealed and gauge Titanium construction For static and dynamic applications Linearity up to ±0.25% FS The XP5 serie is designed in titanium
More information1525-BRS INFORMATION MANUAL SERV O D YN A M ICS. D y n ad r iv e Ave Crocker Suite 10 Valencia, CA
28231 Ave Crocker Suite 10 Valencia, CA 91355 818-700-8600 Servodynamics.com INFORMATION MANUAL 1525-BRS SERV O D YN A M ICS U SA www.servodynamics.com D y n ad r iv e Bru sh INDEX Page INTRODUCTION 2
More informationIAA100/IAA200 Analog Amplifiers Voltage/Current
Quick Start Guide IAA100/IAA200 Analog Amplifiers Voltage/Current Sensor Solutions Source Load Torque Pressure Multi-Axis Calibration Instruments Software www.futek.com Getting Help TECHNICAL SUPPORT For
More informationUSER MANUAL. Integration Kit. Integration Kit for: All Maxwell Technologies BOOSTCAP Ultracapacitor Cells
USER MANUAL Integration Kit for Maxwell Technologies BOOSTCAP Ultracapacitors Integration Kit for: All Maxwell Technologies BOOSTCAP Ultracapacitor Cells 2007 Maxwell Technologies, Inc. 1011158.3 1. Introduction
More informationDynaDrive INFORMATION MANUAL SDFP(S)
DynaDrive INFORMATION MANUAL SDFP(S)1525-17 SERVO DYNAMICS CORP. 28231 Avenue Crocker, Santa Clarita, CA. 91355 (818) 700-8600 Fax (818) 718-6719 www.servodynamics.com INDEX Page INTRODUCTION 2 ELECTRICAL
More informationSignal Conditioning Amplifier
2300 System Micro-Measurements FEATURES Accepts all strain gage inputs (foil and piezoresistive), potentiometers, DCDT s, etc Selectable bridge excitation, 0.7 to 15 VDC (11 steps), plus 0.2 to 7 VDC continuously
More informationOnline data sheet. MLG05S-0895A10802 MLG-2 Prime MEASURING AUTOMATION LIGHT GRIDS
Online data sheet MLG05S-0895A080 MLG- Prime MLG05S-0895A080 MLG- Prime A B C D E F Ordering information Type Part no. MLG05S-0895A080 400 Other models and accessories www.sick.com/mlg-_prime H I J K L
More informationTemposonics. M-Series Analogue/PWM Tester. User s Manual. Absolute, Non-Contact Position Sensors. Document Part Number Revision B
Temposonics Absolute, Non-Contact Position Sensors M-Series Analogue/PWM Tester Document Part Number 551132 Revision B Content 1 The M-Series analogue/pwm Test Kit 1.1 Contents and accessories 1.2 Familiarizing
More informationPRECISION for your Design
PRECISION for your Design everything from a single source 3 everything from a single source Measurement, control, actuation: whenever positions, electrical travels, angles and forces are to be measured
More informationLP SERIES MODEL LP35 LOW PROFILE PROGRAMMABLE ENCODER
LP SERIES MODEL LP35 LOW PROFILE PROGRAMMABLE ENCODER Features Low profile package saves space Excellent resistance to shock and vibration 30mm standard through shaft, PEEK reduction hub available High
More informationPRODUCT DESCRIPTION PAG ES. E110 Series 1PDT, 10 AMP RELAY 2-6. E310 Series 3PDT, 10 AMP RELAY E210 / E215 Series 2PDT, 10/15 AMP RELAY 13-19
Index PRODUCT DESCRIPTION PAG ES E110 Series 1PDT, 10 AMP RELAY 2-6 E310 Series 3PDT, 10 AMP RELAY 7-12 E210 / E215 Series 2PDT, 10/15 AMP RELAY 13-19 E410 / E415 Series 4PDT, 10/15 AMP RELAY 20-24 E610
More informationSHAFTED ROTARY POSITION SENSORS
J8 / J0 / J0 / J30 Shafted ; Brief / of 2 Joral REF S; I / J LINE ENCODERS Joral manufactures shafted rotary position sensors for the market of controls, power equipment, hydraulics, and off road vehicles.
More informationARD154. DIN rail mountable amplifier for strain gage sensors. User s guide. User s guide ARD CONNECTING 4-WIRE SENSORS
6. CONNECTING 4-WIRE SENSORS Connections : S+ connected to module A+ S- connected to module A- Shield connected to A- or to GND of analog output Nota: A- and GND are connected together inside the module.
More informationModel 3A Series 3-Axis Load Cell
Model 3A Series 3-Axis Load Cell 3-Axis Fx Fy Fz; Independent Bridges 20N to 500kN Force Range Compact Size Low Crosstalk Temperature Compensated Accessories BSC4A 4-Channel Analog Amplifier BSC4D 4-Channel
More informationSPECIAL NOTICE. All references to NAT product part numbers (and associated images) are equivalent to AEM product part numbers.
SPECIAL NOTICE This product is now licensed to Anodyne Electronics Manufacturing (AEM) from Northern Airborne Technology (NAT). AEM is responsible for all matters related to this product, including sales,
More informationWeighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier
GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 Weighing System Evaluation Mounting DMS strain gauges (load cells), DMS amplifier
More informationThe MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.
The innovative MPU products incorporate Power Factor Correction (PFC) with a low-profile package designed to meet 1U height constraints. The MPU150-4530G and MPU150-4350G provide high current +3.3 V and
More informationEC 45 flat with integrated electronics Document ID: en Operating Manual
EC 45 flat with integrated electronics Document ID: 919801en Operating Manual Edition June 2017 The EC 45 flat with integrated electronics is a brushless, speed-controlled 1-quadrant drive. It is available
More informationBestech Australia U14/44 Garden Blvd, Tel: Dingley VIC 3172 Fax:
Load Cell F60X Bending beam load cell made of stainless steel, hermetically sealed. Approved up to 6000d R60 OIML. Level of protection IP 68. ATEX 94/9/CE version for hazardous area (option). Designed
More informationPlug-in amplifier. Table of contents. Features. RE 30264/07.12 Replaces: Type VT-SSPA1. Component series 2X 1/8
Plug-in amplifier RE 30264/07.12 Replaces: 03.10 1/8 Type VT-SSPA1 Component series 2X Table of contents Contents Page Features 1 Ordering code, accessories 2 Function 3 Connections and adjustment 3 Block
More informationDMS-20LCD Series. 3½ Digit, LCD Display Low-Cost, Subminiature Digital Panel Voltmeters. Features
www.datel.com Actual Size Series ½ Digit, LCD Display Low-Cost, Subminiature Digital Panel Voltmeters Features Lowest cost Lowest powermw Subminiature size:.8" x 0.88" x 0." 5mm x 22mm x mm Large (0.7"/9.mm),
More informationAnalog Signal Conditioning Accessories
NI 64-channel multiplexer mv, V, current, and thermocouple inputs NI 8-channel simultaneous sample-and-hold mv, V inputs NI SC-2042-RTD 8-channel RTD/thermistor RTD, thermistor, mv, V inputs NI 8-channel
More informationHI 2204LT Loop Powered Level Weight Transmitter OPERATION AND INSTALLATION MANUAL
Loop Powered Level Weight Transmitter OPERATION AND INSTALLATION MANUAL Corporate Headquarters 9440 Carroll Park Drive San Diego, CA 92121 Phone: (858) 278-2900 FAX: (858) 278-6700 Web-Site: http://www.hardysolutions.com
More informationInstallation Guide of Load Cell
Installation Guide of Load Cell Notices Copyright 2000-2014 by Unico, Incorporated. All rights reserved. No part of this publication may be copied, reproduced, or reduced to any electronic media or machine-readable
More informationRon 2000 Shackle Type Dynamometer with Remote Indicator
Ron 00 Shackle Type Dynamometer with Remote Indicator Short delivery time: Usually - 4 business days. High quality Aerospace Steel for increased strength and safety. Exceptionally small dimensions enable
More informationExplosion Proof Page/Talk Paging Amplifier
Industrial Communications Worldwide Explosion Proof Page/Talk Paging Amplifier Installation & Operation 7552-10 th Street. N.E. Calgary Alberta, Canada T2E W1 Ph: 403.25.3100 \ email:info@guardiantelecom.com
More informationTechnical Instructions Document No EA GQD June 23, OpenAir
OpenAir Spring Return, 20 lb-in (2 Nm), Rotary GQD Series, Electronic Damper Actuators Technical Instructions Document No. 155-760 EA GQD Description Features Application The OpenAir GQD Series direct-coupled
More informationHigh Performance Current Transducer IT 200-S ULTRASTAB = A. ε L
High Performance Current Transducer IT 200-S ULTRASTAB For the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation between the primary circuit and the secondary circuit. I PM
More informationHAEHNE. Digital Strain Gauge Amplifier DMA2. Adjustment Instructions. Content
Adjustment Instructions Digital Strain Gauge Amplifier DMA2 Content...Page Operating Mode... 2 Adjustment Modes Zero adjust calibration... 2 Amplification parameter defined by a value (gain)... 2 Amplification
More informationPhone: Fax: Web: -
ue to their sturdy bearing construction in Safety-ock esign, the Sendix 5000 and 500 offer high resistance against vibration and installation errors. The rugged housing, high protection level of up to
More informationWeighing Instruments
GHM Messtechnik GmbH Sales Center International Schloßstraße 6 88453 Erolzheim Germany Fon +49-7354-937233-0 Fax -88 www.ghm-messtechnik.de info@ghm-messtechnik.de Weighing Instruments System Evaluation
More informationTemposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors
Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors M-Series Mobile Hydraulic in-cylinder Sensor Model MH PWM Output Data Sheet SENSORS Document Part Number 551119 Revision B M-Series
More informationBNC-Panel-32-Input User Manual
BNC-Panel-32-Input User Manual Used to mate any input signals on BNC Connectors to a Digital Lynx AC or DC Input Board. Neuralynx, Inc. 105 Commercial Drive, Bozeman, MT 59715 Phone 406.585.4542 Fax 866.585.1743
More information