General Specifications

Size: px
Start display at page:

Download "General Specifications"

Transcription

1 General Specifications µr800 Recorder GS 04H03B0-0E The µr800 is a compact recorder with a recording width of 80mm. The model family consists of,, 3, 4 pen and 6,, 8, 4 dot model. Pen models realize continuous recording for each channel, whereas the dot-printing model realizes a high recording speed of 6dot / 0sec., dot / 5sec., 8dot / 0sec., 4dot / 30sec. Its input is universal, which means that it is freely selectable to use inputs like direct voltage, Thermo-couple, Resistance Temperature Detector, contact input, etc. In addition to analog recording, digital data like date & time, measured values, tags, units, scale values, chart speed, alarms, calculated values, etc. can also be printed. High reliability is realized by in house developed contact free technology, such as high breakdown voltage semiconductor relays, and DC brushless servomotors. Furthermore the µr800 has a short case of only 0mm. Good readability is realized by using 5 7 VFD display and its setting is made easy because of the interactive program menu. Real time data is also displayed as a bargraph. The µr800 can be used as a monitoring device and as a quality control instrument in many applications (such as process temperature monitoring, pollution, construction, furnaces, field of medical diagnosis, field of refrigerating, etc.). STANDARD SPECIFICATIONS General Specifications Construction Mounting: Flush Panel Mounting (vertical) Mounting may be inclined up to 30, rear below front (with horizontal base). Allowable panel thickness: to 6mm Material: Case: drawn steel, front door: aluminium die casting. Finish: Case and door-frame: lamp black (Mansell 0.8Y.5 / 0.4 or equivalent) Door: Splash and dust-proof (based on DIN IP54). Dimensions: mm (see dimensional drawings) Weight (approx.): pen 8.9kg 6 dot 9.kg pen 9.0kg dot 9.4kg 3 pen 9.kg 8 dot 9.5kg 4 pen 9.4kg 4 dot 9.6kg µr800 (4-dot model) Model,, 3, and 4 pen, 6,, 8, and 4 dot-model. Input Inputs: DCV: Direct Current Voltage input 0mV to 0V range. TC: Thermo couple. RTD: Resistance Temperature Detector. DI: Digital Input (contact or DC Voltage, TTL level). DCA: Direct Current Input (using external shunt resistor (0Ω, 00Ω, 50Ω) ) Measuring range: selectable per channel Input Type Range Measuring Range DC V 0 mv 60 mv 00 mv V 6 V 0 V 0.00 to 0.00mV to 60.00mV 00.0 to 00.0mV.000 to.000v to 6.000V 0.00 to 0.00V T00.EPS 55 Takamuro-cho, Kofu-shi, Yamanashi-ken, Japan Phone: Facsimile: GS 04H03B0-0E Copyright May. 99(YK) 8th Edition Feb. 004(YG)

2 Input Type Range TC RTD R* S* B* K* E* J* T* N* W* 3 L* 4 U* 4 Measuring Range C 0.0 to C 0.0 to C 0.0 to 80.0 C 00.0 to C 00.0 to C 00.0 to 00.0 C 00.0 to C 0.0 to C 0.0 to 35.0 C 00.0 to C 00.0 to C Measuring Range F 3 to 300 F 3 to 300 F 3 to 3308 F 38.0 to 498 F 38.0 to 47.0 F 38.0 to 0.0 F 38.0 to 75.0 F 3 to 37 F 3 to 499 F 38.0 to 65.0 F 38.0 to 75.0 F Input Type Range Measuring Range C Measuring Range F DI (Digital Input) Pt00* 5 JPt00* 5 Input Type Range Voltage Input Contact Input 00.0 to C 00.0 to C Measuring Range 38.0 to.0 F 38.0 to 0.0 F less than.4v: OFF; more than.4v: ON (TTL) contact ON / OFF * R, S, B, K, E, J, T: ANSI, IEC 584, DIN IEC 584, JIS C * N:Nicrosil-Nisil, IEC 584, DIN IEC 584 *3 W:W 5% Re-W 6% Re (Hoskins Mfg Co) *4 L: Fe-CuNi, DIN 4370 U: Cu-CuNi, DIN 4370 *5 Pt00: JIS C , JIS C , IEC 75, DIN IEC 75 JPt00: JIS C , JIS C T00.EPS Measurement Interval: Pen model: 5ms / channel Dot printing model:.5s / 6-, -, 8-, 4dot In case of 00ms integration:.5s / 6 dot, 5s / dot, 0s / 8 dot, 0s / 4 dot A / D Integration Time: AUTO / FIX selectable AUTO: 0ms (50Hz) or 6.7ms (60Hz), automatically selected depending on the power supply frequency. FIX: 0ms (50Hz), 6.7ms (60Hz) or 00ms (50 / 60Hz) can be set. 00ms integration time for dot printing model only TC Burnout: ON / OFF selectable (per channel) Burnout upscale / downscale selectable (common for all channels) Normal: less than kω, burnout: more than 0MΩ Measuring current: approx. 00nA. Filter: Pen model: Signal damping (ON / OFF selectable per channel; in case of ON: time constant from, 5, 0sec). Dot printing model: Moving average (ON / OFF selectable per channel; in case of ON: averaging times from to 6 scans). Calculation: Differential computation: Between any two channels, however reference channel number must be less than measuring channel number. Available for DCV, TC, and RTD range. Both channels must have same range. Linear scaling: Available for DCV, TC and RTD range. Scaling limits: 0000 to 0000 Data display & printout range: 9999 to 0000 Decimal point: user selectable (should be specified when entering scale value) Unit: user settable, up to 6 characters (alphanumerical & special characters). Square root: Available for DCV range. Scaling limits: 0000 to 0000 Data display & printout range: 9999 to 0000 Decimal point: user selectable Unit: user settable, up to 6 characters (alphanumerical & special characters). Recording and Printing Recording Method: Pen model: Disposable felt pens, Plotter pen Dot printing model: 6 color wire dot. Pen Offset Compensation: ON / OFF selectable (Pen model only) Effective Recording Width: 80mm Chart: Plain-paper Z-fold chart (0m) Step Response Time (pen): Less than.5sec (acc. to IEC TC85 method). Recording Period: Pen model: Continuous for each channel. Dot printing model: Max. 6 dot / 0sec, dot / 5sec, 8 dot / 0sec, 4 dot / 30sec, AUTO / FIX selectable AUTO:Analog recording interval is depending on the chart speed FIX: Analog recording interval is set to shortest period Chart Speed: Pen model: 5 to 000mm/h (8 increments) Dot printing model: to 500mm/h (mm step) Chart Speed Change: speed, speed change by remote control signals (option). Chart Speed Accuracy: within ± 0.% (for recordings longer than 000mm, related to the grid of the chart paper) All Rights Reserved. Copyright 997, Yokogawa Electric Corporation GS 04H03B0-0E 7th Edition: Sep.30,00-00

3 Relation between Chart Speed and : (Pen-model) Chart Speed 5to 9mm/h 0 to 500mm/h 600 to 000mm/h (6-, -dot model) Chart Speed to 9mm/h 0 to 00mm/h 0 to 500mm/h (8-, 4-dot model) Chart Speed to 9mm/h 0 to 50mm/h 5 to 500mm/h Periodic Channel No. or Tag No. Channel No. or Tag No. Periodic Periodic Alarm Message Chart Speed Change Time T030.EPS Alarm Message Chart Speed Change Time T030.EPS Alarm Message Chart Speed Change Time T0303.EPS Relation between chart speed and printing intervals of periodic printouts: (Pen-model) Chart Speed 5 to 9mm/h 0 to 8mm/h 0 to 36mm/h 40 to 7mm/h 75 to 35mm/h 50 to 80mm/h 00 to 30mm/h 360 to 500mm/h more than 600mm/h Printing Interval of Periodic Every 8 hours Every 4 hours Every hours Every hour Every 30 minutes Every 0 minutes Every 0 minutes T0304.EPS (Dot-printing model) Chart Speed Printing Interval of Periodic 6-dot model -dot model 8-dot model 4-dot model to 9mm/h 0 to 9mm/h Every 8 hours Every hours Every hours Every 4 hours 0 to 39mm/h Every 4 hours Every 8 hours Every 8 hours Every hours 40 to 50mm/h Every hours Every 4 hours Every 4 hours Every 8 hours 5 to 79mm/h Every hours Every 4 hours 80 to 00mm/h Every hour Every hours 0 to 500mm/h T0305.EPS 3 Recording Colors: Pen model: pen=red, pen=green, pen3=blue, pen4=violet, plotter pen=purple Dot printing model: ch, 7, 3, 9=purple, ch, 8, 4, 0=red, ch3, 9, 5, =green, ch4, 0, 6, =blue, ch5,, 7, 3=brown, ch6,, 8, 4=black (color can be assigned to any channel) Recording Format:. Analog recording: Zone recording: Span: More than 5mm (in mm steps). Partial expanded recording: Boundary position: to 99% Boundary value: Within recording span. Digital printout: Channel (dot model only): Channel number or TAG will be printed during analog recording. Approx. every 5mm this print will occur. Alarm: At the right side of the chart, CH. No. or TAG, Type of alarm, ON / OFF time (h/m) will be printed. It is selectable to get ON / OFF time of alarms, or ON time, or no alarms (common for all channels). Periodic printout: At the left side of the chart, date (m/d), time (h/m) chart speed, and measured data of every channel will be printed. Printing interval is INT / EXT selectable. INT: Using internal timer. Depending on chart speed or on interval which is selectable (up to 4 hours). EXT: Using remote control option Channel No. or TAG printout: Selectable, common for all channels. Measuring printout: ON / OFF selectable for each channel. Scale printout: Recording span more than 40mm, at 0% and 00% values will be printed. (When using partial expanded recording, boundary value will also be printed). ON / OFF selectable (common for all channels) of recording colors (pen model only) Date, time and chart speed Message printout: Using panel key or remote control option. Up to 5 messages. Contents: time (h/m) and message (up to 6 characters). Record start time: Time (h/m) will be printed when recording starts, ON / OFF selectable Chart speed printout: Time (h/m) when chart speed is changed will be printed, ON / OFF selectable. All Rights Reserved. Copyright 997, Yokogawa Electric Corporation GS 04H03B0-0E 7th Edition: Sep.30,00-00

4 List printout: Listings of range and alarm setting, etc. will be printed. Manual printout: Using panel key or remote control option. Measured values of that moment will be printed, while trend recording will be interrupted. SET UP List printout: Listings of settings in SET UP Mode will be printed. Display Display Method: VFD (5 7 dot matrix, 0 characters). Digitial Display: AUTO Channel No. or TAG No., kind of alarm, measured values, unit (when TAG No. is displayed, front 4 characters), for each channel alternately MANUAL Channel No., kind of alarm, measured values, unit (when TAG No. is displayed, front 4 characters), for one specific channel CLOCK Year / month / date and hour / min / sec will be displayed VIEW Operating status of IC memory card will be displayed Bargraph Display: Measured data Alarm Left-referenced (%) bargraph and center zero bargraph (selectable for each channel). Setting level of alarm, in case of alarm flashing display. Alarm status display: Channel No. will be displayed in case of alarm (dot model only) Other Displays: RCD:Recording in progress, POC: Pen offset compensation (pen model only), SET: Set mode, ALM: Shared alarm (not corresponding to any channel), CHT: Chart end indicator (optional), BAT: Low battery. AUTO, MAN, CLK: Display status of operation mode Power Supply Rated Power Voltage: 00 to 40VAC, automatically selected depending on the power supply voltage Usable power voltage ranges: 90 to 3, 80 to 50VAC Rated Power Frequency: 50 / 60 Hz, automatically selected Power Consumption: (approx.) 4 pen 6,, 8, 4 dot * : In Balance 00VAC Power Source 30VA* 3VA* 40VAC Power Source 40VA* 3VA* Maximum 70VA 70VA T040.EPS 4 Alarm Number of levels: Up to four levels for every channel (High, Low, Delta high, Delta low, High-rate-of-change, Low-rate-of change selectable). Interval time of rate-of-change alarm is the measuring interval times to 5 (selectable, and common for both rate-of-change alarms). Display: Set value: It is indicated as a point on the bargraph. In case of an alarm: This point will start flashing on the bargraph and the digital display will show the kind of alarm and alarm indicator in different display will show alarm For the dot model, the channel No. where the alarm occurred will also be displayed. Hysteresis: Approx. 0.5% of recording span (only High, Low alarm) and 0%, selectable (common for all channels and all levels). Alarm indication when ALARM ACK-key is pressed: Non-hold-type: Alarm display is not affected when the ALARM ACK-key is pressed. Hold-type: When alarm occurs, alarm indicator will start flashing. After ALARM ACK-key is pressed, indicator will show status of the alarm. Hold-type: Alarm ON Alarm OFF Indicator BLINK Indicator ON Indicator OFF ACK Non-hold type: No action will occur when ACK-key is pressed. ALM indicator depends on alarm status. or ACK F040.EPS Other Specifications Clock: With Calendar function Clock Accuracy: 00 ppm, however not including error due to turning ON / OFF power Panel Key Lock: By actual key Internal illumination: By using the internal reflection of VFD indicator All Rights Reserved. Copyright 997, Yokogawa Electric Corporation GS 04H03B0-0E 7th Edition: Sep.30,00-00

5 Memory backup: Lithium battery to protect setting parameters. Life is approx. ten years (at room temperature, and for standard model) and is installed inside the recorder. If the battery runs down, it will be indicated on the front panel indicator. Insulation Resistance: Each terminal to ground terminal: more than 0M (measured at 500VDC). Dielectric Strength: Power supply to ground terminal: 500V AC (50 / 60Hz), min Contact output terminal to ground: 500V AC (50 / 60Hz), min Measuring input terminal to ground: 000V AC (50 / 60Hz), min Between measuring input terminals: 000V AC (50 / 60Hz), min (except for RTD, since b-terminal is common). Between remote control terminal to ground: 500V DC, min. Machine noise: Machine Noise Information Ordinance 3. GSGV, Jan. 8, 99: The maximum sound pressure level is equal or less than 60dB (A) according to ISO7779. CSA CSA. No00.(NRTL/C*) installation category II, pollution degree * For marking that includes NRTL, a mark with US (USA) printed on the right side of the CSA mark, and C (Canada) printed on the left side appears on this instrument. CE EMC directive: EN636 compliance (Emission: Class A, Immunity: Annex A) EN compliant EN compliant EN550 compliant, Class A Group Low voltage directive: EN600- compliant, measurement category II, pollution degree C-Tick AS/NZS 064 compliant, Class A Group Normal Operating Conditions Power voltage: 90 to 3, 80 to 50VAC Power frequency: 50Hz ± %, 60Hz ± % Ambient temperature: 0 to 50 C Ambient humidity: 0 to 80% RH (at 5 to 40 C) Vibration: 0 to 60Hz, less than 0.0G Shock: not permissible Magnetic field: less than 400A/m (DC and 50, 60Hz) 5 Noise: Normal Mode (50 / 60Hz) DCV Peak value including signal must be less than. times the measuring range. TC Peak value including signal must be less than. times the measuring thermal electromotive force. RTD less than 50mV. Common Mode (50 / 60Hz) less than 50VAC rms. for the whole range Maximum Differential Noise between Channels (50 / 60Hz) less than 50VAC rms for 6,, dot model less than 00VAC rms for 8, 4 dot model * In case of / N (3 leg RTD) is combined less than 00VAC rms for 6 dot model less than 00VAC rms for, 8, 4 dot model Operating Position: Frontwards: 0 Backwards: within 30 from horizontal Warm-up Time: Min 30 minutes after power has been turned ON. All Rights Reserved. Copyright 997, Yokogawa Electric Corporation GS 04H03B0-0E 8th Edition: Feb

6 6 Standard Performance Measuring and Recording Accuracy: (following specifications apply to operation of the recorder under standard operation conditions: temperature 3 ± C, humidity 55 ± 0%RH, power supply voltage 90 to 3V, 80 to 50V AC, power supply frequency 50/60Hz ± %, warmup time at least 30 minutes, other ambient conditions like vibration should not adversely affect the recording operation). Input DC V Range 0mV 60mV 00mV V 6V 0V Measuring (digital display) Measurement Accuracy ± (0.% of rdg+3 digits) ± (0.% of rdg+ digits) ± (0.% of rdg+ digits) ± (0.% of rdg+ digits) ± (0.3% of rdg+ digits) ± (0.3% of rdg+ digits) Max. Resolution 0 µv 0 µv 00 µv mv mv 0mV Recording (analog) Recording Accuracy Resolution Measurement accuracy ± (0.3% of recording span) Pen model dead band: 0.% of recording span Dot printing model resolution: 0.mm TC R S B K E J T N ± (0.5% of rdg+ C) but R, S : 0 to 00 C, ± 3.7 C 00 to 300 C, ±.5 C B : 400 to 600 C, ± C accuracy less than 400 C is not specified ± (0.5% of rdg+0.7 C) but 00 to 00 C ± (0.5% of rdg+ C) ± (0.5% of rdg+0.5 C) ± (0.5% of rdg+0.5 C) but J : 00 to 00 C ± (0.5% of rdg+0.7 C) ± (0.5% of rdg+0.7 C) 0. C 0. C Measurement accuracy ± (0.3% of recording span) Pen model dead band: 0.% of recording span Dot printing model resolution: 0.mm W ± (0.5% of rdg+ C) 0. C L U ± (0.5% of rdg+0.5 C) but L : 00 to 00 C ± (0.5% of rdg+0.7 C) 0. C RTD Pt00 JPt00 ± (0.5% of rdg+0.3 C) 0. C Measurement accuracy ± (0.3% of recording span) Pen model dead band: 0.% of recording span Dot printing model resolution: 0.mm NOTE: Recording span is 80 mm. Accuracy in case of scaling: accuracy during scaling (digits) = measuring accuracy (digits) multiplier + digits (rounded up) Where the multiplier = scaling span digits / recording span digits Example: DCV 6V range recording span :.000 to 5.000V scaling span : to.000 measuring accuracy = ± (0.3% 5V + digits) ± (0.05V (5 digits) + ) ± (7 digits) multiplier = 000 digits (0.000 to.000) / 4000 digits (.000 to 5.000V) = 0.5 Accuracy during scaling =7 digits = digits (rounded up) T060.EPS All Rights Reserved. Copyright 997, Yokogawa Electric Corporation GS 04H03B0-0E 7th Edition: Sep.30,00-00

7 Maximum Allowable Input Voltage: Less than VDC ranges and TC ranges: ± 0VDC (cont.) 6V to 0VDC: ± 30VDC (cont.) Reference Junction Compensation: INT / EXT selectable (per channel) Reference Junction Compensation Accuracy (above 0 C): Type R, S, B, W: ± C Type K, J, E, T, N, L, U: ± 0.5 C Input Resistance: More than 0M (TC, 0mV, 60mV, 00mV, V range) Approx. M (6, 0V range). Input Source Resistance: DCV, TC input: less than k RTD input: less than 0 / wire (Resistance is wellbalanced between 3 wires) Input Bias Current: less than 0nA (however, when burnout is specified for TC:00nA). Maximum Common Mode Voltage: 50VAC rms (50 / 60Hz) Maximum Differential Noise between Channels: 50VAC rms (50 / 60Hz) for 6, dot model 00VAC rms (50 / 60Hz) for 8, 4 dot model * In case of / N (3 leg RTD) is combined 00VAC rms (50 / 60Hz) for 6 dot model 00VAC rms (50 / 60Hz) for, 8, 4 dot model Interference between Channels: 0dB (500, the deviation in the case that 30V is applied to another channel) Common Mode Rejection Ratio: 0dB (50/60Hz ± 0.%, 500 imbalance between terminal and ground) Normal Mode Rejection Ratio: 40dB (50 / 60Hz ± 0.%) Effect of Operating Conditions Effect of Ambient Temperature: Effect of ambient temperature variation of 0 C. Digital display:within ± (0.% of rdg+ digit) Recording: within Digital display ± 0.% of recording span (excluding RJC error) Effect of Power Supply: Effect of variation within 90 to 3V or 80 to 50VAC in rated power supply voltage: (50 or 60Hz is reference) Digital display: within ± digit Recording: within ± 0.% of recording span Effect of rated power frequency variation of ± Hz (00VAC is reference): Digital display: within ± (0.% of rdg+ digit) Recording: same as digital display 7 Effect of Magnetic Field: Effect of AC (50 / 60Hz) or DC 400AT/m field: Digital display: within ± (0.% of rdg+0 digits) Recording: less than ± 0.5% of recording span Effect of Radio-frequency Electromagnetic Field: Effect of MHz, 0V/m field (Pen model) Digital display: within ± (5% of range + digit) Recording: within ± (5% of range) (Dot model) Digital display: within ± (0% of range + digit) Recording: within ± (0% of range) Effect of Radio-frequency Common Mode: Effect of MHz, 0V Digital display: within ± (5% of range + digit) Recording: within ± (5% of range) Effect of Input Source Resistance: Effect of Input Source Resistance variation of +k : DCV range: Ranges less than V: within ± 0 µv Ranges more than 6V: within 0.% of rdg TC range: within ± 0 µv (However ± 00 µv when TC burnout protection is set) RTD range: Effect of 0 per wire (resistances of three wires must be equal): Digital display: within ± (0.% of rdg+ digit) Recording: within Digital display ± 0.% of recording span Effect of difference of three wires: Digital display: 0. C per 40 m (approx.) Effect of Operating Position: Digital display: within ± (0.% of rdg+ digit) (within 30 backwards) Recording: within Digital display ± 0.% of recording span (within 30 backwards) Vibration: Effect when sine-wave motion of frequency 0 to 60Hz and acceleration of 0.0G is applied to the instrument in the direction of three axes for two hours: Digital display: within ± (0.% of rdg+ digit) Recording: within Digital display ± 0.% of recording span Transport and Storage Conditions No malfunction will occur under these conditions, however when returning to normal operation conditions, calibration might be necessary. Temperature: 5 C to 60 C Humidity: 5 to 95% RH (no condensation) Vibration: 0 to 60Hz 0.5G Shock: less than 40G (inside packing) All Rights Reserved. Copyright 997, Yokogawa Electric Corporation GS 04H03B0-0E 7th Edition: Sep.30,00-00

8 SPECIFICATIONS OF OPTIONAL FUNCTIONS / A: Alarm Output Relay ( contacts) / A: Alarm Output Relay (4 contacts) / A3: Alarm Output Relay (6 contacts) / A4: Alarm Output Relay ( contacts) / A5: Alarm Output Relay (4 contacts) When alarm occurs, output relay on rear terminal will be activated.. Output is AND / OR selectable.. Energize/ non-energize selectable (common for all relays). 3. Hold type/ non-hold type selectable (common for all relays). 4. Reflash relay: When alarms occurs, specific output relay point can reflash (can be assigned to 3 points max) 5. Relay contact rating: DC 50V / 0.A AC 50V / 3A 6. Type of relay output: NO-C-NC Note : Alarm ACK key: Non-Hold type: No effect when ALARM ACK-key is pressed (no effect on output relay). Hold type: When-ALARM ACK-key is pressed, the output relay will be reset. Non-hold-type: Alarm ON Alarm OFF Relay SET Relay RESET Hold-type: Alarm ON Alarm OFF Relay SET Relay RESET ACK (ex. ) ACK F080.EPS Hold-type: Alarm ON Alarm OFF Relay SET Relay RESET (ex. ) ACK 8 F080.EPS / C3: RS-4A Communication Interface By using this communication function, setting and control of data can be done by a host-computer. Data can also be output to the host-computer.. Synchronizing format: start-stop asynchronous transmission. Specifications: conform to EIA RS-4A standard 3. Communication principle: 4-wire half-duplex multi-drop connection (: N (N= to 6)) 4. Communication rate: 75, 50, 300, 600, 00, 400, 4800, 9600bps 5. Data length: 7 or 8 bit 6. Stop bit: or bit 7. Parity: Odd, even or none 8. Communication distance: Up to 500m 9. Communication mode: ASCII (control / setting / measured data) or Binary (measured data) / E: IC Memory Card Slot Saving and retrieving setting parameters / E: IC Memory Card Slot Specifications Memory Data : Setting data, measured data, calculated data and programmed parameter can be stored on a memory card. However, the retrieving and recording of math channels is not possible. Sample Mode : In writing : Free mode (sampling start manually) Trigger mode (sampling start by external trigger) In reading :Free mode Sample Rate : Pen model :Measurement interval (5ms)/ sec./ min./ min. Dot model :Measurement interval / min. / min. Memory Capacity : M byte, 5k byte All Rights Reserved. Copyright 997, Yokogawa Electric Corporation GS 04H03B0-0E 8th Edition: Feb

9 Data Length : 500 / 000 / 000 / 4000 / 8000 / 6000 / 3000 data / ch (measurement channel byte / data, math channel 4 byte / data) Trigger Conditions : External contact * (wire the relay output to the remote terminal in case alarm and chart-end detector is treated as trigger.) Pre - Trigger : 0 to 00%, in ten steps Output : Recording ; * Regardless the number of inputs, the same products have interchangeability. ex. µr800 6 dot model µr800 dot model µr000 pen model µr800 4 pen model µr800 pen model µr800 6 dot model * Retrieving data is according to the measurement interval of the recorder which plays back. * The recording interval of the dot model depends on the setting of the recorder which plays back. Battery Backup : Lithium battery (battery life about years / 5k, about year / M) / F: FAIL / Chart End Detection and Output If an error in the CPU board occurs, or when the chart reaches its end, output relay on the rear terminal will be activated. Besides, when the chart reaches its end, CHT indicator will be shown on the display. Relay contact rating: DC 50V / 0.A, AC 50V / 3A / H: Clamped Input Terminal Using clamped input terminals as input terminal. / H3: Non-glare Door Glass Provides non-reflective glass in the front door. / H5 : Portable Type Provides carrying handle and power code. / M: Mathematical Functions. General computation: ()General computation channel: Using measurement channels ()Types: Arithmetic functions (,,, ) SQR (square root) ABS (absolute value) LOG (y=log 0X) EXP (exponential) Relational computation (<, >,, ) Logical computation (AND, OR, XOR, NOT). However, between two channels only. (3)Constant 9. Statistical computation ()Types of statistics: MAX, MIN, AVE, SUM (Totalization) ()Recording: Digital printout (time depends on interval) only. Analog recording is not possible. / N: 3 Leg Isolated RTD Input A, B, b legs are of isolated input type. / P: 4VDC Power Supply Rated supply voltage: 4VDC Applicable supply voltage range:.6 to 6.4VDC Maximum power consumption: Approx. 50VA / R: Remote Control 5 are selectable from the below mentioned remote controls. Number of settings Signal Recording start / stop level Chart speed change level Message printout start* 5 trigger Manual printout start trigger Statistical computation start / stop* level Periodic printout start trigger Start saving of measured data to IC memory card* 3 trigger * Up to 5 messages can be set * / M option is necessary *3 / E option is necessary / L: French / German / English Display & Winter / Summer Time English, German or French display can be selected. Winter and summer time can be set. / N: Cu0, Cu5 RTD input Cu0 and Cu5 input become available instead of Pt00 and JPt00. If this option is specified, Pt00 and JPt00 input is not available. Cu0, Cu5 Measurement Range RTD Input Type Cu0(GE) : α = at 5 C Cu0(L&N) : α = at 5 C Cu0(WEED) : α = at 5 C Cu0(BAILEY) : Non-Linear Cu0 : α = at 0 C Cu0 : α = at 0 C Cu5 : α = at 0 C Measurement Range 00 to 300 C (38 to 57 F) T090.EPS All Rights Reserved. Copyright 997, Yokogawa Electric Corporation GS 04H03B0-0E 8th Edition: Feb

10 0 Measurement / Recording Accuracy Input Type Cu0(GE) : α = at 5 C Cu0(L&N) : α = at 5 C Cu0(WEED) : α = at 5 C Cu0(BAILEY) : Non-Linear Cu0 : α = at 0 C Cu0 : α = at 0 C Cu5 : α = at 0 C Measurement Accuracy ± (0.4% of rdg +.0 C) ± (0.3% of rdg C) Recording Accuracy Measurement Accuracy ± (0.3% of Recording span) T00.EPS /N3: Pt50, RTD, PR0-40, Platinel TC input Pt50, PR0-40 and Platinel input become available. These inputs can be used in combination with all other standard inputs. Pt50, PR0-40, Platinel Measurement Range Input Type Measurement Range TC RTD PR0-40 Platinel Pt50 0 to 900 C (3 to 55 F) 0 to 400 C (3 to 55 F) 00 to 600 C (38 to F) Measurement / Recording Accuracy T00.EPS PR0-40 Platinel Pt50 Input Type 0 to 450 C 450 to 750 C 750 to 00 C 00 to 900 C Measurement Accuracy Not specified ± (0.9% of rdg+3. C) ± (0.9% of rdg+.3 C) ± (0.9% of rdg+0.4 C) ± (0.5% of rdg+.3 C) ± (0.3% of rdg+0.6 C) Recording Accuracy Measurement Accuracy ± (0.3% of Recording span) T003.EPS / N5: Remote RJC Remote RJC function (compensating wire saving type) becomes available. * Measurement is possible only if the thermocouples of the reference channel (RJC channel) and the measurement channel are of the same type. * RJC channel must be smaller than the measurement channel. All Rights Reserved. Copyright 997, Yokogawa Electric Corporation GS 04H03B0-0E 7th Edition: Sep.30,00-00

11 MODEL AND SUFFIX CODES Model Code Option Code / Description µr800 pen recorder µr800 pen recorder µr800 3 pen recorder µr800 4 pen recorder µr800 6 dot recorder µr800 dot recorder µr800 8 dot recorder µr800 4 dot recorder See option code table. *: only one of /A, /A, /A3, /A4, /A5 can be selected *: /F cannot be combined with /A5. In case of 6-dot model, /F cannot be combined with /A4. *3: /H cannot be combined with /N. *4: If /N is specified, Pt00 and JPt00 input is not available. *5: /H5 B: Power cord JIS st d D: Power cord UL st d F: Power cord VDE st d R: Power cord AS st d J: Power cord BS st d V: Power cord GB st d /H5 cannot be combined with /P. OPTION CODES Option Code / A / A / A3 / A4 / A5 / C3 / E / E / F / H / H3 / H5 / M / N / N / N3 / N5 / P / R / L Description Alarm output relay ( contacts) Alarm output relay (4 contacts) * Alarm output relay (6 contacts) Alarm output relay ( contacts) (dot printing model only) Alarm output relay (4 contacts) (, 8, 4 dot model only) RS-4A Interface IC Memory Card Slot with SET UP data read / write function IC Memory Card Slot with SET UP, measurement data read / write function FAIL / Chart end detection and output * Clamped input terminal * 3 Non-glare door glass Portable type * 5 Mathematical Computations Cu0, Cu5 RTD input * 4 3 leg RTD (dot printing model only) * 3 Pt50 RTD, PR0-40, Platinel TC input Remote RJC 4VDC power supply Remote controls (5 plugs) STANDARD ACCESSORIES Name pen pen 3 pen 4 pen 6,, 8, 4 dot Z-fold chart 6 color ribbon cassette Disposable felt-pen cartridge Plotter pen Mounting brackets Key (for key lock) Fuse (50V 800mA Timelag) (4VDC model : 50V 5A Timelag) Instruction Manual Reference sheet (Quick operation guide) Red Green Blue Violet Purple SPARES Name Z-fold chart 6 color ribbon cassette 6 color ribbon cassette (for TAIWAN) Disposable felt-pen cartridge Red Green Blue Violet Purple Plotter pen Mounting brackets Key (for key lock) Fuse (50V 800mA Timelag) Parts No. B9573AN B9906JA B9906JF* B990AM B990AN B990AP B990AQ B990AR B9900BX B9900HZ A5EF Order Q ty (units) 0 Fuse for 4VDC model (50V 5A Timelag) A53EF 3 pieces / unit Lubricating oil piece / unit B990AZ (for dot printing model) * In case of orders for spares for TAIWAN, please order this part No. Description chart / unit piece / unit piece / unit 3 pieces / unit 3 pieces / unit 3 pieces / unit 3 pieces / unit 3 pieces / unit piece / unit piece / unit 4 pieces / unit OPTIONAL ACCESSORIES Name Shunt resistor (for screw input terminal) Shunt resistor (for clamped input terminal) IC Memory Card Model Code Specification 50Ω ± 0.% 00Ω ± 0.% 0Ω ± 0.% 50Ω ± 0.% 00Ω ± 0.% 0Ω ± 0.% 5k byte M byte T0.EPS All Rights Reserved. Copyright 997, Yokogawa Electric Corporation GS 04H03B0-0E 8th Edition: Feb

12 REAR TERMINAL ARRANGEMENTS Input Terminals 4 Pen Screw Type /B +/A -/b CH CH CH3 CH4 6 Dot Screw Type 4 Pen Clamped Type (/H) /b +/A -/B CH CH CH3 CH4 CH5 CH6 CH CH4 CH /B CH3 +/A -/b 6 Dot Clamped Type (/H) +/A -/B CH CH CH4 CH6 /b CH3 CH5 F0.EPS All Rights Reserved. Copyright 997, Yokogawa Electric Corporation GS 04H03B0-0E 7th Edition: Sep.30,00-00

13 3 Option Terminals /A /C3 /F /R Combination /A4 /C3 /R Combination Alarm Output Relay 3 4 Alarm Output Relay Chart End Output 5 FAIL Output C SD SD A B SG RD RD A B FG Remote Control Communication (RS-4A) C SD SD A B SG RD RD A B FG Remote Control Communication (RS-4A) /A5 /A Alarm Output Relay F30.EPS All Rights Reserved. Copyright 997, Yokogawa Electric Corporation GS 04H03B0-0E 7th Edition: Sep.30,00-00

14 4 DIMENSION Unit : mm (approx. inch) 79.6 (.0) (.56) 80 (7.09) 80.5 (7.) to 6 (panel thickness) 80 (7.09) 08 (4.5) 88 (.34) 94.6 (.6) 80.5 (7.) 4 (0.94) 0 (8.66) 39.5 (.56) 9.4 (0.37) (min. space for mounting) 79.6 (.0) (4.5) 54.6 (.5) 88 (.34) 94.6 (.6) 7.5 (0.30) (dimension after mounting) Note) The µr800 should be mounted by only two brackets, either on the top & bottom of the recorder, or on the left & right side of the recorder. If not specified, the tolerance is ±3%. However, in cases of less than 0mm, the tolerance is ±0.3mm. All Rights Reserved. Copyright 997, Yokogawa Electric Corporation GS 04H03B0-0E 7th Edition: Sep.30,00-00

General Specifications

General Specifications General Specifications µrs800 Recorders GS0H0B0-00E µrs800 recorders are compact recorder with 80mm recording width, available as standard in,, 3, -pen, and 6,, 8, -point dot-printing models. These recorders

More information

VIEW RECORDERS SPECIFICATIONS

VIEW RECORDERS SPECIFICATIONS SPECIFICATIONS Input points: µr1000:1,2,3,4,(pen),6(dot)point µr1800:1, 2, 3, 4, (pen), 6, 12, 18, and 24 (dot) point Input signals, range, and measurement range limits: Input RANGE Range 20 mv 20.00 to

More information

General Specifications

General Specifications General Specifications µrs000 Recorders µrs000 recorders are compact recorder with 00mm recording width, available as standard in -pen, 2-pen, 3- pen, 4-pen, and 6-point dot-printing models. These recorders

More information

General Specifications

General Specifications General Specifications SR Recorder LF 4D8B-4U The SR is a small compact recorder using a mm (4 inch) wide paper. The family consists of,,3 pen and a 6 dot model. Its input is universal, which means that

More information

µr SERIES RECORDERS VIEW RECORDERS 4365 & 4375 Recorders FUNCTIONS FEATURES

µr SERIES RECORDERS VIEW RECORDERS 4365 & 4375 Recorders FUNCTIONS FEATURES 4365 & 4375 Recorders VIEW RECORDERS Splash and dust-proof door permits use even in poor environments. (Based on DIN 40050-IP54). Depth is a mere 220 mm, enabling significant instrument panel space savings.

More information

General Specifications

General Specifications General Specifications µr0000 Recorder GS 04P0B0-0E The µr0000 is a compact recorder with a recording width of 80mm. The model family consists of,, 3, 4 pen and a 6,,8, 4 dot models. Pen model realizes

More information

General Specifications

General Specifications General Specifications SR0000 Recorder GS 04P03B0-0E The SR0000 is a compact recorder with a recording width of 00mm. The model family consists of,, 3, 4 pen and a 6 dot models. Pen model realizes continuous

More information

General Specifications

General Specifications General Specifications µr0000 Recorder GS 04P0B0-0E The µr0000 is a compact recorder with a recording width of 00mm. The model family consists of,, 3, 4 pen and a 6 dot models. Pen model realizes continuous

More information

General Specifications

General Specifications General Specifications MODEL UT50L Limit Controller GS 5DD-0E Overview The UT50L is an FM approved limit controller that can be configured either as a high limit or as a low limit controller by a user.

More information

HYBRID RECORDER OUTLINE

HYBRID RECORDER OUTLINE Specifications Sheet No.SPEC-33E (st Edition) RM0C HYRID RECORDER OUTLINE RM0C is 00mm calibrated hybrid recorder in a 44x44 DIN front panel and short depth of 50mm case housing. The recorder has versatility

More information

Easy-to-read in either English, French, or German; 20-digit, 2-line display; 6-channel simultaneous display possible

Easy-to-read in either English, French, or German; 20-digit, 2-line display; 6-channel simultaneous display possible PHA & PHC STRIP CHART RECORDERS WITH BRILLIANT SIX-COLOR PRINTING Why use dot-matrix or fiber-tip pen printing when Fuji Electric s patented, cutting-edge recording technology offers an affordable inkjet

More information

General Specifications

General Specifications General Specifications MODEL UM0 Digital Indicator with Alarms GS 0F0D00E General Model UM0 Digital Indicator with Alarms is a precision alarm instrument with universal input /8DIN. For excellent monitoring

More information

DIGITAL THERMOMETER Digital Thermometer FEATURES INDEX RECORDERS

DIGITAL THERMOMETER Digital Thermometer FEATURES INDEX RECORDERS Digital Thermometer 23 88 350 mm 3 kg (8-5/8 3-/2 3-3/4" 6.6 lbs) The Digital Thermometer has 6 ranges of temperature sensors and measuring functions of DC V and Ω. YOKOGAWA-original A/D converter (feedback

More information

DIGITAL THERMOMETER VIEW RECORDERS Digital Thermometer FEATURES

DIGITAL THERMOMETER VIEW RECORDERS Digital Thermometer FEATURES Digital Thermometer High-Accuracy Reference Junction Compensation: Compensation accuracy (±0.2 C) Input terminals are provided on both front and rear panels, and an input site is switch selectable. The

More information

General Specifications

General Specifications General Specifications View Recorder Wide-View Model VR00 GS NA-E OVERVIEW The VR00 is a PAPER-LESS recorder that displays realtime measured data on a color LCD and saves data on a.5-inch floppy disk.

More information

General Specifications

General Specifications General Specifications Model UT, UT Temperature Controller GS CE-E GENERAL UT series temperature controllers provide only the functions and size you require for your application. /6 DIN sizes is available.

More information

General Specifications

General Specifications General Specifications Model UM350 Digital Indicator with Alarms GS 05F0D00E General Model UM350 Digital Indicator with Alarms is a precision alarm instrument with universal input. For excellent monitoring

More information

General Specifications

General Specifications General Specifications Model UM330 Digital Indicator with Alarms GS 05F0D00E General Model UM330 Digital Indicator with Alarms is a precision alarm instrument with universal input /8DIN. For excellent

More information

General Specifications

General Specifications General Specifications GS 05F01D01E MODEL UM351 Digital Indicator with Alarms with Active Color PV Display General Model UM351 Digital Indicator with Alarms is a precision alarm instrument provided with

More information

DPR100 C/D PEN AND MULTIPOINT 100 mm DIGITAL RECORDERS

DPR100 C/D PEN AND MULTIPOINT 100 mm DIGITAL RECORDERS PEN AND MULTIPOINT 100 mm DIGITAL RECORDERS EN0I-6021 06/2003 PRODUCT SPECIFICATION SHEET PRODUCT DESCRIPTION The DPR 100 C and D recorders are designed to meet the recording needs for most recording applications.

More information

General Specifications

General Specifications General Specifications GS 0F01D0E Model UM1 Digital Indicator with Alarms with Active Color PV Display General Model UM1 Digital Indicator with Alarms is a precision 1/8 DIN alarm instrument provided with

More information

General Specifications

General Specifications General Specifications GS 0F01D01E Model UM1 Digital Indicator with Alarms with Active Color PV Display General Model UM1 Digital Indicator with Alarms is a precision alarm instrument provided with universal

More information

General Specifications

General Specifications General Specifications MW100-E-1X/X/X/S15 Special Edition 1. MW100/S15 Hardware Specification MW100 Logging type Mainly standalone measurement and distributed remote measurement Style No. S3 Maximum number

More information

SHIMADEN DIGITAL INDICATORS

SHIMADEN DIGITAL INDICATORS Shimaden, Temperature and Humidity Control Specialists C %RH Series SD16 & SHIMADEN DIGITAL INDICATORS & NRTL /C approved BASIC FEATURES DIN Size 48 x 96 mm ±.3% High Accuracy Indication Large 2 mm bright

More information

General Specifications

General Specifications General Specifications GS 77J01Q08-01E Model VJQ8 Pulse to Analog Converter (Multi-function) (Isolated Single-output and Isolated Dual-output Types) General This plug-in type pulse to analog converter

More information

6/12/24 Dot Printing Model Smart Recorder SRF206/212/224

6/12/24 Dot Printing Model Smart Recorder SRF206/212/224 No. CP-SS-E // Dot Printing Model Smart Recorder SRF0// The Smart Recorder SRF 0// Dot Printing Model accepts DC voltage, thermocouple, resistance temperature detector (RTD), communications and ON/OFF

More information

DIGITAL MULTIMETERS 7561 & & 7562 Digital Multimeters FEATURES RECORDERS INDEX

DIGITAL MULTIMETERS 7561 & & 7562 Digital Multimeters FEATURES RECORDERS INDEX 756 & 7562 756 & 7562 Digital Multimeters 756 (6-/2 digits) 23 88 330 mm 3 kg (8-3/8 3-/2 3" 6.6 lbs) 7562 (6-/2 digits) 23 88 330 mm 3 kg (8-3/8 3-/2 3" 6.6 lbs) The 7560 (6-/2 digit display) Series is

More information

SHIMADEN DIGITAL INDICATORS

SHIMADEN DIGITAL INDICATORS Shimaden, Temperature and Humidity Control Specialists C %RH Series SD16A & SHIMADEN DIGITAL INDICATORS approved,ul applied BASIC FEATURES compliance DIN Size 48 x 96 mm ±.3% High Accuracy Indication Large

More information

General Specifications

General Specifications General Specifications GS 04L53B01-01EN GX90XA/GX90XD GX90YD/GX90WD I/O Modules OVERVIEW I/O modules are connected to the GX/GP, Expandable I/O unit, GM main unit, and GM sub unit. A module type is four

More information

DIGITAL MULTIMETERS VIEW RECORDERS & 7562 Digital Multimeters FUNCTIONS FEATURES

DIGITAL MULTIMETERS VIEW RECORDERS & 7562 Digital Multimeters FUNCTIONS FEATURES 756 & 7562 Digital Multimeters 756 (6-/2 digits) 23 88 330 mm 3 kg (8-3/8 3-/2 3" 6.6 lbs) 7562 (6-/2 digits) 23 88 330 mm 3 kg (8-3/8 3-/2 3" 6.6 lbs) The 7560 (6-/2 digit display) Series is a high-accuracy,

More information

SHIMADEN PROGRAM CONTROLLER

SHIMADEN PROGRAM CONTROLLER Shimaden, Temperature and Humidity Control Specialists C %RH SHIMADEN PROGRAM CONTROLLER approved BASIC FEATURES Full multi-input and multi-range performance User selectable Thermocouple, RTD, V, mv and

More information

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

MODEL: M2XU MODEL: M2XU [1][2] [3][4] Super-mini Signal Conditioners Mini-M Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Accepts direct inputs from various sensors and provides a standard process signal I/O types and

More information

SHIMADEN DIGITAL INDICATOR

SHIMADEN DIGITAL INDICATOR Shimaden, Temperature and Humidity Control Specialists C %RH Series SD24 & KR16A SHIMADEN DIGITAL INDICATOR BASIC FEATURES ohigh Accuracy ±0.1% FS+1 digit o1/1000ºc Resolution Indication Possible (Pt input

More information

DIGITAL PROGRAM CONTROLLER

DIGITAL PROGRAM CONTROLLER KP1000 SERIES DIGITAL PROGRAM CONTROLLER The KP1000 series is a 96x96mm digital program controller with the indicating accuracy of ±0.1%, the control cycle of approximately 0.1 seconds and maximum 19 program

More information

v v PMA With numerous functions and robust construction, the KS 3930 A/B line recorders are ideal for universal industrial applications.

v v PMA With numerous functions and robust construction, the KS 3930 A/B line recorders are ideal for universal industrial applications. v v PMA Line recorder KS 3930 A KS 3930 B Galvanically isolated input channels for simple connection Measuring and recording range freely configurable Maintenance-free recording system Universal cassette

More information

MICROJET RECORDER (100mm)

MICROJET RECORDER (100mm) MICROJET RECORDER (1mm) DATA SHEET PHC This recorder can record a maximum of 6 channels of DC voltage, ma, thermocouples and resistance bulbs. The adoption of an ink jet system makes it possible to record

More information

Paperless Recorder PR20

Paperless Recorder PR20 Technical Information TI 075R/24/ae Paperless Recorder PR20 Economical and time saving recorder operates without the need for paper or pens and is exceedingly simple to operate Application Areas Technological

More information

General Specifications

General Specifications General Specifications GX90XA/GX90XD/GX90YD/ GX90WD/GX90XP/GX90YA I/O Modules GS 04L53B01-01EN OVERVIEW I/O modules are connected to the GX/GP, Expandable I/O unit, GM main unit, and GM sub unit. A module

More information

General Specifications

General Specifications General Specifications GS 77J0A070E Model VJA7 Distributor (Multifunction) (Isolated Singleoutput and Isolated Dualoutput Types) Overview This plugin type distributor is used in combination with wire type

More information

BH Series 180mm CHART PEN-PRINTING TYPE HYBRID RECORDER

BH Series 180mm CHART PEN-PRINTING TYPE HYBRID RECORDER BH Series 180mm CHART PEN-PRINTING TYPE HYBRID RECORDER MODEL BH The BH series 180mm-chart pen-writing hybrid recorder can easily be operated in the same wayas in operating an analog recorder. It is provided

More information

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals Accessories High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals WIKA data sheet AC 80.03 Applications Machine building

More information

MODEL: R30US4. Remote I/O R30 Series

MODEL: R30US4. Remote I/O R30 Series Remote I/O R30 Series UNIVERSAL INPUT MODULE (4 points, isolated) Functions & Features 4 points universal input I/O module Isolation between the channels Input range of each channel is individually adjustable

More information

Fuzzy Temperature Controllers E5AF

Fuzzy Temperature Controllers E5AF Fuzzy Temperature Controllers 1/4 DIN Controller Combines Fuzzy and PID Control For Fast Response to Process Disturbances Advanced PID control provides optimal response during start-up and steadystate

More information

POINTAX 6000L2 Point Recorder

POINTAX 6000L2 Point Recorder GOSSEN METRAWATT CAMILLE BAUER Special Features 6 measuring channels Last printed point visible from front Electrically isolated, earth-free measuring channels Process signals ranging from 0/4... 20 ma,

More information

Light-weight and Flexible Multi-function Portable Hybrid Recorder

Light-weight and Flexible Multi-function Portable Hybrid Recorder Portable Hybrid Recorder DR130 Small, light-weight and portable Data can be saved to a floppy disk A wealth of PC-based application software Mutually isolated channels, and universal inputs Large display,

More information

Temperature Controllers E5 J

Temperature Controllers E5 J Temperature Controllers Advanced PID Controller with Fuzzy Logic-Based Adaptive Tuning Provides Optimum Performance Available in 3 standard DIN sizes: Choose 1/4, 1/8 and 1/16 DIN Fuzzy adaptive tuning

More information

Digital indicator for panel mounting With multi-function input Model DI25

Digital indicator for panel mounting With multi-function input Model DI25 Accessories Digital indicator for panel mounting With multi-function input Model DI25 WIKA data sheet AC 80.02 Applications Plant construction Machine tools Plastics technology and processing Ventilation

More information

Portable Hybrid Recorder DR130

Portable Hybrid Recorder DR130 Portable Hybrid Recorder DR130 Small, light-weight and portable Data can be saved to a floppy disk A wealth of PC-based application software Mutually isolated channels, and universal inputs Large display,

More information

MICRO-CONTROLLER X (48 48 mm)

MICRO-CONTROLLER X (48 48 mm) PX series digital temperature controller MICRO-CONTROLLER X ( mm) DATA SHEET PXG PXG is a compact size temperature controller of front panel size mm. To cope with any of versatile uses as a temperature

More information

SDM3045X Digital Multimeter. DataSheet

SDM3045X Digital Multimeter. DataSheet SDM3045X Digital Multimeter DataSheet-2016.06 User-friendly Design Product Overview SDM3045X is a 4½ digit digital (60000 count) multimeter incorporating a dual-display and is especially well suited for

More information

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT Space-saving Two-wire Signal Conditioners B3-UNIT 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe) Functions & Features Universal input: mv, V, T/C, RTD, resistance, potentiometer

More information

LINAX 4000L Continuous-line recorder

LINAX 4000L Continuous-line recorder -48-852-0 4/2.99 1 to 4 line channels Format 144 mm x 144 mm, mounting depth 250 mm Combined recording table for roll chart (2 m) or fanfold chart (16 m) Measuring channels electrically isolated Rugged

More information

High Performance Process & Temperature Controllers

High Performance Process & Temperature Controllers C22 C62 C82 C83 High Performance Process & Temperature Controllers C72 C42 R22 01. Multi Color LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. 200 msec Sampling Rate 04. True Universal

More information

DC1010/DC1020/DC1030/DC1040

DC1010/DC1020/DC1030/DC1040 05/0 0-10-10-0-EN Page 1 of DC1010/DC1020/DC100/DC1040 DIGITAL CONTROLLERS Specification Overview The DC1000 Series are microprocessorbased controllers designed with a high degree of functionality and

More information

100mm Recorders Specification Sheet

100mm Recorders Specification Sheet 4103C, 4103M MODELS 100mm Recorders Specification Sheet The 4103 is a high specification, 100mm strip chart recorder, providing continuous recording for up to 6 Process Variables. Information such as Channel

More information

DIGEM f 96 x 48 EK. Applications. Description

DIGEM f 96 x 48 EK. Applications. Description 3-349-002-03 1/7.98 Front panel dimensions: 96 x 48 mm LED display: red or green, 14 mm high Max. display range: 19 999 to + 32 765 Modular connectors for flexible use Simple adjustments at front panel

More information

Process displays For standard signals, temperature, resistance measurement

Process displays For standard signals, temperature, resistance measurement Features Inputs: Voltage ±10 V, ±200 V / Current ±20 ma / thermocouples J,K,T,N,Pt100,Pt1000 / resistance measurement / potentiometer Display range can be linearised Two limits output Min, Max functions

More information

CompoBus/D-type Digital Controller

CompoBus/D-type Digital Controller CompoBus/D-type Digital Controller Digital Controller for the CompoBus/D and Conforming the DeviceNet Conforms the DeviceNet and connects a Programmable Controller without any programming. High performance

More information

DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification

DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification 01 May 20 30-10-10--EN Page 1 of DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification Overview The DC1000 Series are microprocessorbased controllers designed with a high degree of

More information

[3] MOUNTING DIRECTION

[3] MOUNTING DIRECTION Bargraph Indicators N Series BARGRAPH INDICATOR Functions & Features Displays two process variables in dual graphic bargraphs of LED segments Single and dual bargraphs IP front cover plate is easily replaced

More information

General Specifications

General Specifications General Specifications Signal Conditioner Cards OUTLINE Signal Conditioner Cards, which interface to the process, are installed in Signal Conditioner Nests. [Release 6] The signal conditioner cards can

More information

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

C330 / C330X PC-Programmable Universal, 2-wire Transmitter C330 / C330X PC-Programmable Universal, 2-wire Transmitter The IPAQ C330 transmitter is a universal, isolated, temperature transmitter with additional voltage and resistance input. Its robust design and

More information

General Specifications

General Specifications General Specifications GS 05P01F31-01EN UT32A Digital Indicating Controller (Entry model) Functional Enhancement Overview The UT32A entry model digital indicating controller is an easily configurable single-loop

More information

APPENDIX APPENDIX A 1

APPENDIX APPENDIX A 1 A 1 SPECIFICATIONS Ratings Supply voltage 100 to 240 VAC, 50/60 Hz 24 VAC, 50/60 Hz/24 VDC Operating voltage range 85 to 110% of rated supply voltage Power consumption 7VA 4VA/2.5W Sensor input Thermocouple

More information

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4] Tension-Clamp Ultra-Slim Signal Conditioners M6S Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection Universal input (mv, V, ma, T/C, RTD and potentiometer)

More information

General Specifications

General Specifications General I/O Adaptors (for N-IO) GS 33J62F30-01EN [Release 6] GENERAL This General (GS) describes the hardware specifications of I/O adaptors that enable extended functions setting for analog digital I/O

More information

MODEL: W2TS. Mini-MW Series

MODEL: W2TS. Mini-MW Series Space-saving Dual Output Signal Conditioners Mini-MW Series THERMOCOUPLE TRANSMITTER Functions & Features Accepts direct input from a thermocouple and provides a standard process signal 5-segment linearization

More information

Excellent low-cost Process & Temperature Controllers

Excellent low-cost Process & Temperature Controllers C22 C62 C82 C83 Excellent low-cost Process & Temperature Controllers C72 C42 R22 01. High Quality LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. The Fast Sampling Rate in 200

More information

SHIMADEN DIGITAL CONTROLLER

SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists C %RH Series SR9 SHIMADEN DIGITAL CONTROLLER ASIC FEATURES Multi-input and multi-range performance Large mm bright display (SR9) Readable from a distance

More information

SR25. SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists MICROPROCESSOR-BASED AUOT-TUNING PID CONTROLLER

SR25. SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists MICROPROCESSOR-BASED AUOT-TUNING PID CONTROLLER SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists SERIES SR25 MICROPROCESSOR-BASED AUOT-TUNING PID CONTROLLER High Accuracy ±0.1% High Sampling Cycle 0.1 sec. Auto-Tuning

More information

DIGITAL INDICATING CONTROLLER

DIGITAL INDICATING CONTROLLER DB00 SERIES DIGITAL INDICATING CONTROLLER The DB00 series is a digital indicating controller with the indicating accuracy of ±0.% and the control cycle of approximately 0. seconds. Various functions including

More information

OSCILLOGRAPHIC RECORDERS

OSCILLOGRAPHIC RECORDERS ORP00 / ORP300 & ORM00 / ORM300 780&780 Oscillographic Recorders ORP00 / ORP300 ORM00 / ORM300 * * ORM00 (780) 30 9 435mm 8.8kg (4-ch model) to 9.5kg (8-ch model) (-5/8 7-/6 7-3/6" 9.4 lbs (4ch model)

More information

General Specifications

General Specifications General Specifications UM33A Digital Indicator with Alarms [Style: S9] Overview The UM33A digital indicator with Alarms employ an easy-to-read, 14-segment large color LCD display, along with navigation

More information

ADAM 4000/4100 Series

ADAM 4000/4100 Series ADAM 4000/4100 Series Common Dimensions Communication RS-485 (2-wire) to host Speeds: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps (ADAM-4080, ADAM-4080D only support up to 38400 bps) Max. communication

More information

10-CH Digital Thermometer Module

10-CH Digital Thermometer Module User's Manual 10-CH Digital Thermometer Module 3rd Edition 3rd Edition Thank you for purchasing the 10-CH Digital Thermometer WE7241 for the PC-based measurement instruments, WE7000. This User s Manual

More information

Basic module X-TIO FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10 FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10. Communications (RS-485)

Basic module X-TIO FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10 FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10. Communications (RS-485) Module type High-speed Digital ler SRX SRX General Description The SRX is a module type digital controller with a super high speed sampling of control updating cycle time of ms (0.0 sec). Dual loop control

More information

User s Manual. Models SR10001/SR10002/SR10003/SR10004/ SR SR10000 Recorder IM 04P03B01-01E. 3rd Edition. Yokogawa Electric Corporation

User s Manual. Models SR10001/SR10002/SR10003/SR10004/ SR SR10000 Recorder IM 04P03B01-01E. 3rd Edition. Yokogawa Electric Corporation User s Manual Models SR10001/SR10002/SR10003/SR10004/ SR10006 SR10000 Recorder Yokogawa Electric Corporation 3rd Edition Thank you for purchasing the YOKOGAWA SR10000 Recorder. This user s manual explains

More information

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE

More information

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER Configuration Code TM01 Series 642 Programmable HART Field Temperature The Series 642 programmable HART field temperature transmitter is a 2-wire unit with analog output. It includes input for RTDs; resistance

More information

PROGRAM CONTROLLER OUTLINE

PROGRAM CONTROLLER OUTLINE Specifications Sheet No.SPEC-1232E (1st Edition) EC1200A PROGRAM CONTROLLER OUTLINE The EC1200 can, totally and with high precision, control and monitor such factors as temperature, temperature balance

More information

SRX. General Description. Features. Module type High-speed Digital Controller SRX. Multi-Zone Space-Saving. High-speed Feedback Control

SRX. General Description. Features. Module type High-speed Digital Controller SRX. Multi-Zone Space-Saving. High-speed Feedback Control SX General Description The SX is a module type digital controller with a super high speed sampling of control updating cycle time of ms (0.0 sec). Dual loop control can be performed with a single compact

More information

High-precision process calibrator Model CED7000

High-precision process calibrator Model CED7000 Calibration technology High-precision process calibrator Model CED7000 WIKA data sheet CT 85.51 Applications Research and development laboratories Calibration service companies and service industry Industry

More information

Chapter 6 Specifications

Chapter 6 Specifications Chapter 6 Specifications DC Characteristics Function Range [2] Test Current or Burden Voltage DC Voltage DC Current Resistance [6] 24 Hour [3] T CAL ±1 Accuracy Specifications: ± (% of reading + % of range)

More information

DIN rail mounting temperature controller with current transformer input deltadue series D1 line

DIN rail mounting temperature controller with current transformer input deltadue series D1 line BT.. D/E S E R I E S DIN rail mounting temperature controller with current transformer input deltadue series D line The controller with load control The deltadue series includes a powerful DIN rail mounting

More information

Specifications. 744 Users Manual

Specifications. 744 Users Manual 80T-150U Temperature Probe 80PK series thermocouples 80i-410 Clamp-on DC/AC Current Probe 80i-1010 Clamp-on DC/AC Current Probe 80i-500s Clamp-on AC Current Probe (requires the Y9108 adapter) 80i-1000s

More information

SR100 (Multi-point Type)

SR100 (Multi-point Type) No. CP-SS-1890E SR100 (Multi-point Type) Hybrid Recorder Overview The SR100 Hybrid Recorder is a 6-point recorder with an LCD digital display for easy reading of measured values. This recorder has three

More information

PROCESS & TEMPERATURE CONTROLLERS

PROCESS & TEMPERATURE CONTROLLERS PROCESS & TEMPERATURE CONTROLLERS NOVA PD54 Series Thermocouple, RTD, & Process Inputs High Accuracy Auto-Tuning PID Heating & Cooling Models Universal Power Supply 1-24 VAC Up to 3 Relays & 2 Analog Outputs

More information

DP2000 ORDERING GUIDE To Order MODEL NO.

DP2000 ORDERING GUIDE To Order MODEL NO. 1 8 DIN VERSATILE PROCESS MONITORS CONFIGURABLE DP2000-S, 1 8 DIN meter, shown smaller than actual size. DP2000 Series Complete with Input Board RoHS 2 Compliant DP2000-J1, with TJ36-ICSS-116G-12, transition

More information

Temperature Input Module for Zone 1 Series 9482/32

Temperature Input Module for Zone 1 Series 9482/32 www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >

More information

General Specifications

General Specifications General Specifications YTA70 Temperature Transmitter The YTA70 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a to 0 ma DC

More information

Overcurrent Protection / 7SJ45

Overcurrent Protection / 7SJ45 Overcurrent Protection / SJ SIPROTEC easy SJ numerical overcurrent protection relay powered by CTs Fig. / Description SIPROTEC easy SJ numerical overcurrent protection relay powered by current transformers

More information

AIO and DIO PFXLM4B01DAK:Sink Output Type PFXLM401DAC:Source Output Type Virtual Resolution (pixels)

AIO and DIO PFXLM4B01DAK:Sink Output Type PFXLM401DAC:Source Output Type Virtual Resolution (pixels) Model:PFXLM4B01DDK PFXLM4B01DDC PFXLM4B01DAK PFXLM4B01DAC LT4000M Rear module Model Name Indication PFXLM4B01 D * * (1) (2) (3) (4) Notice to our valued customers who use LT4000M series (analog model)

More information

Instruction Manual. SR1000 Recorder IM 4D8B1-S05E. IM 4D8B1-S05E 4th Edition

Instruction Manual. SR1000 Recorder IM 4D8B1-S05E. IM 4D8B1-S05E 4th Edition Instruction Manual SR1000 Recorder 4th Edition INTRODUCTION Thank you for purchasing the YOKOGAWA industrial strip-chart recorder. The SR1000 recorder comforms to the EMC standard as follows. EM1 EN55011:

More information

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs SINEAX V 6 for rail mounting in housing P/7 or P/7 St 00 II () GD Application SINEAX V 6 (Figs. and ) is designed for measuring temperature in combination with thermocouples or resistance thermometers.

More information

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters Industrial Loop Isolators and Transmitters DSCL,, SCTP DSCL,, SCTP Industrial Loop Isolators and Transmitters Description Dataforth s DSCL,, and SCTP series of products is a complete family of loop and

More information

MICRO-CONTROLLER X (96 96 mm)

MICRO-CONTROLLER X (96 96 mm) PX series digital temperature controller MICRO-CONTROLLER X ( mm) DATA SHEET PXG PXG is a compact size temperature controller of front panel size mm. To cope with any of versatile uses as a temperature

More information

MODEL: M1EXT. with Display M1E Series

MODEL: M1EXT. with Display M1E Series 2 Channel Super-mini Signal Conditioners with Display M1E Series THERMOCOUPLE TRANSMITTER (2 channels, PC programmable) Functions & Features Accepts direct input from a thermocouple and provides a linearized

More information

Models UT550/UT520 Digital Indicating Controllers User s Manual for Loop Control for Backup

Models UT550/UT520 Digital Indicating Controllers User s Manual for Loop Control for Backup Instruction Manual Models UT550/UT520 Digital Indicating Controllers User s Manual for Loop Control for Backup IM 05D01C02-45E IM 05D01C02-45E 1st Edition Blank Page Introduction Thank you

More information

Bipolar Output Working Standard

Bipolar Output Working Standard 6166 DC Voltage/Current Source 6½-digit working standard suitable for calibration High-accuracy and highly stable with bipolar output l Wide dynamic range and high resolution Voltage source: ±10nV to ±1200V

More information

Digital Controller Intelligent, User-friendly Digital Controller and Programmer Controlled with ease with a support software which is input via the communication jack on the front panel. Minute adjustment

More information