1 Mains Powered Modbus Transmitter QC0150 Manual Ref: QC0150 Version: JAN17 1.0
2 System Concept RF Transmitters connect to sensors or meters and send data to the infrastructure internet connected Gateway on site The Gateway stores and transfers the data to the Realtime Online cloud server over a secure mobile cellular connection Realtime Online provides a web based portal of visualisation dashboards, reports, graphs and transmits out tailored automatic reports and notifications in the event of exceptions Version Tracking Date Author Changes v Chris Boddy Invisible Systems Limited P a g e 2
3 INDEX Contents 1. Introduction Applications Safety Requirements prior to Install Preparation Correct connection of the data cables into the Modbus Transmitter from the Modbus Device Examples of Metering Equipment that is compatible with the modbus equipment Sensor Numbering Locating Sensors Checking operation Meter Validation Appendix 1 Part Numbers Document Name Manual Description Version QC0140 Unboxed Ultra RF Gateway 1.0 QC0141 Boxed Ultra RF Gateway 1.0 QC Phase Wireless Meter 1.0 QC Channel Sub-meter 1.0 QC0144 Optical Pulse Transmitter 1.0 QC0145a Pulse Transmitter (Electric meter)instalation Guide 1.0 QC0145b Pulse Transmitter (Gas meter)instalation Guide 1.0 QC0145c Pulse Transmitter (Water meter)instalation Guide 1.0 QC Channel Sub Meter 1.0 QC0147 Modbus Panel Meter Installation Guide 1.0 QC0148 Pulse GRP Single/ Double Panel Meter 1.0 QC0149 Rx/Tx-ULTRA RF-Repeater Instruction Manual 1.0 QC0150 Mains Powered Modbus Transmitter 1.0 QC0151 2mtr Temperature Transmitter 1.0 Invisible Systems Limited P a g e 3
4 1. Introduction Modbus connection is a high-level protocol for industrial networks developed in 1979 by Modicon (now Schneider Automation Inc.). It defines a request/response message structure for a client/server environment. Modbus runs over various data links i.e serial links such as RS-232 and RS-485 including its own Modbus network. The Modbus Transmitter has the capability to connect to several different kinds of Modbus devices to allow data to be retrieved via a modbus connection. Several different types of Modbus Devices are available; Schneider PM750 Schneider PM5100 Socomec Diris A21 Socomec Diris A41 Multicube Metering Panels etc The setup and connection of these devices to third party meters will require reference to the relevant manufacturer s installation documents relating to each device, as the modbus registers can be different depending on what is required by the customer. The Modbus Transmitter will be programmed according to its designated purpose that is confirmed during the ordering phase. Features A variety of available radio frequency options Small footprint Automatic data collection and transmission Wireless, range of up to 15km line of sight Technical information Operating frequency 868MHz (Other frequencies available 915 MHz) Operating range up to 15km Suitable to monitor allocated meters to which it is programmed Storage Conditions: 0 C to +50 C Relative Humidity: 25% to 95% Operating Temperature: 0 C to 40 C Mains powered Measurement type in line with output it is monitoring. Measurement Accuracy in line with equipment it is connected to. Invisible Systems Limited P a g e 4
5 2. Applications On installations where exsisting meters have a unused Modbus Connection. Energy Monitoring Bill validation Sub-metering Where there is a available Modbus Connection at the chosen metering point and quantity and type of meter is confirmed, the Modbus Transmitter is capable of transmitting the chosen Registars from the meter into the Gateway reciever for remote monitoring. Examples (*where meter is capable) Kwh Import Kwh Export* Line Voltage* Phase Voltage* Amps Per Phase* Other registars may be available when the meter type is confirmed as the Modbus Transmitter can be programmed at the factory to accomodate many different senarios but is limited to what the chosen meter can deliver. 3. Safety This manual gives details of safe installation of Modbus Transmitter. Safety may be impaired if the instructions are not followed or the system is used in a manner not specified by the manufacturer. Labels give details of equipment ratings for safe operation. Take time to examine all labels before commencing installation. Safety symbols on the meter have specific meanings. Caution Risk of Danger Refer to Instructions Danger Risk of Electric Shock Safety may be impaired if the instructions are not followed or the meter is used in a manner not specified by the manufacturer. The Device contains no user serviceable parts. Field wiring and commissioning should only be carried out by qualified personnel, in compliance with applicable national regulations. E.g. National Electrical Code (NEC) for US; Canadian Electrical Code for Canada For further Information contact the manufacturer: Address: Invisible Systems, 9 Beetham Road, Milnthorpe, Cumbria, LA7 7QL Web: Invisible Systems Limited P a g e 5
6 Voltage Circuits Safety The Modbus Transmitter requires a Mains supply rated at 240v and comes complete with 13amp plug as standard. An adequate protection device must be available within the attached circuit to provide a safe means of disconnection. Caution Care should be taken when mounting and drilling holes in the designated cabinet as the cables present on the inside of the enclosure will need to be avoided When connecting to this type of meter the correct safety protocols for site would need to be followed when working on electrical equipment and reference to the particular meter manual will be required, it is recomended to contact a qualified electrician for this work Maintenance The equipment should be maintained in good working order. Damaged equipment must be returned to the manufacturer (or his authorised agent) for repair. The meter may be cleaned by wiping lightly with a soft cloth. No solvents or cleaning agents should be used. All inputs and supplies must be isolated before cleaning any part of the equipment. Invisible Systems Limited P a g e 6
7 4. Requirements prior to Install. Information Needed from allocated metering positions. Meter Type/Model Quantity Circuit Names Modbus Address Registar Reads Required Confirmation of compatable Baud Rate Settings Confirmation of compatable Parity Settings The below table will need to be filled in prior to receiveing the Modbus Transmitter as it will be programmed to your specific requirements. This can be ed to you by Invisible Systems Ltd prior to equipment being sent. Ref QC0151. It is Advised that the maximum number of registar addresses on one Modbus Transmitter be 30. This Info will be used to set up your Realtime Online Portal by Invisible Systems Prior to installation. Invisible Systems Limited P a g e 7
8 5. Preparation Ensure the area you are going to be working in is clean and tidy. This includes any tools or equipment you have are stored neatly away so as to ensure there is no trip hazard. Find a suitable location for mounting the Modbus Transmitter. Clear of obstacles, on a flat dry surface not in close proximity to water. Also ensure there are no buried cables or pipe work close to a power outlet. Note It is advised that if where possible the Modbus Transmitter is fitted to a 5amp switched fused spur to ensure inadvertant disconnection from supply. Refer to qualified electrician should this be needed. Example below shows a Modbus Transmitter fitted to associated meters with a reciever in situe also Invisible Systems Limited P a g e 8
9 6. Correct connection of the data cables into the Modbus Transmitter from the Modbus Device. The data connection is made by three wires from the allocated Modbus Meters into the Modbus Transmitter, the connection of these cables is important as they are polarity sensitive and will not work if connected incorrectly. There is a label located on the side of the Modbus Transmitter showing correct orientation of the cables for connection. Under no circumstances should the cover be removed while the Transmitter is plugged in the available mains supply Under no circumstances should the Transmitter be mounted on any form of asbestos boards- Check asbestos register prior to any work commencing Example-Modbus Connections Modbus Transmitter As shown each meter is show as a slave, it is advisable that the last meter in the modbus loop be checked to see if there is a 120 ohm Termination Resistor present. This is more important where the modbus chain is approaching 100mtrs as the resistor helps clean the signal being sent by the meters to the Modbus Transmitter. The installation of the data cable between the Modbus Transmitter and the Modbus Device must be fitted in such a way that sufficient mechanical protection is provided as per IEE Wiring Regulations 17 th Edition Invisible Systems Limited P a g e 9
10 RS485 Connections The connection from the Modbus Transmitter (RS485) shall only be connected to low voltage (SELV) circuits. The maximum operating voltage for an RS485 network is 12Vdc. Cables with a minimum of 1 twisted pair + 1 single core with an overall shield should be used. A twisted pair should be used for network lines A(+) and B( ) and a single core or second twisted pair for 0V. Many specialist cables are available for RS485 but shielded CAT 5e cable (4 twisted pairs) may also be used. Cables running within the electrical enclosure may come close to high voltages and therefore must be insulated to the following minimum specification: RS485 Cables: UL 1015, 105 DegC, 600Vac AWG. 7. Examples of Metering Equipment that is compatible with the modbus equipment. Several different types of Modbus Devices are available; Schneider PM750 The Sequence below shows how to record/change the values in the meter. Invisible Systems Limited P a g e 10
11 Example of Registers required to be recorded to allow correct operation; if other registers are required further info can be found in the manufactures manual Mtr Type Input Registar Unit PM Total KWH High word kwh Socomec Diris A10 Diris A21/A40 Connections The Table below shows the values that need to be advised in the meter.. Mtr Type Input Registar Unit Diris A Total KWH High word kwh Diris A Total KWH High word kwh Diris A Total KWH High word kwh EM21 Meter Invisible Systems Limited P a g e 11
12 8. Sensor Numbering Example Each sensor is supplied with a unique serial number marked on the side together with a barcode which is used to identify the sensor on the Realtime-Online dashboard. It is vital that these numbers are accurately recorded as otherwise it will be impossible to identify the sensor in ISL Setup or the server dashboard for the specific site. Note that a sensor number cannot appear twice on the same site, but can appear on more than one site dashboard. 9. Locating Sensors Realtime-Online Sensors use radio frequency communication to a local gateway. The distance between sensors and the gateway can also be very long (up to 15Km line of sight). However, environmental factors such as walls and furniture can reduce this distance considerably so optimal placement of sensors is important. Note that this document does not specifically cover the installation of Gateways which are covered in a separate document, (see index) but the following general guidance is given. When placing sensors, avoid the following: a. Placing the transmitter in metal enclosures such as a distribution boards. b. The transmitters are splashproof and are suitable for installation in outdoor areas, but are not 100% waterproof. Do not install them in positions where they are liable to be submerged. c. Do not install the transmitters close to other RF sources such as alarm systems, door openers or other radio systems. Although the amount of RF energy transmitted by the sensors is very small indeed, there is a possibility that they could interfere with other electrical devices, so they must not be installed close to other devices which could be affected e.g. medical devices or wireless alarm systems. Invisible Systems Limited P a g e 12
13 When siting the gateway, try to ensure that the location is approximately equidistant in radio signal terms from all the sensors. Typically, sensors can be expected to pass through 4 5 normal internal walls without difficulty. The following illustration shows how sensors which are hidden behind large metal objects like tanks or steel walls may have difficulty in transmitting to the gateway. Possible repeater location Notes Care must be taken when installing this sensor as live electrical circuits are usually within the vicinity. Seek to guidance of a qualified electrician if you are unsure. Invisible Systems Limited P a g e 13
14 7. Checking operation Following installation of the Pulse transmitter, it is suggested that the operation is checked to ensure the transmitter is being received by the Gateway. Open Ultra RF Gateway Setup This should be located on the desktop of your laptop. On first use, if requested, select the USB lead being used and highlight for use. Name lead connection and select it in drop down list Screen information being displayed. The Screen will show the transmitters it can see in range of the receiver, these can be sorted by sensor type or ID as per preference. Invisible Systems Limited P a g e 14
15 Each Transmitter will show the following 1. Sensor ID 2. Transmitter Type 3. Battery Voltage 4. Values being received 5. Signal Strength and frequency It is important to check all of this information to confirm that each sensor is being seen by the gateway and at regular intervals in relation to (5). Blue colour dots show direct messages being received and Orange colour dots show messages received via repeaters. Correct setup and operation of Realtime-online, will require all the Sensor ID s and Transmitter types in conjunction with the Gateway ID. The RSSI is shown in dbm with a bar chart showing signal strength. This is an important parameter. The table below shows dbm ranges in relation to Signal strength. The range shown above reads -100dBm this is shown in the table as a Marginal signal therefore will need improving either by reviewing the transmitter location, moving the Gateway closer or adding a signal repeater in between transmitter and receiver. Value RSSI Signal RSSI Signal Value dbm Strength dbm Strength Marginal Good Marginal Good Marginal Good Marginal Excellent Marginal Excellent 7-99 Marginal Excellent 8-97 Marginal Excellent 9-95 Marginal Excellent OK Excellent OK Excellent OK Excellent OK Excellent OK Excellent Good Excellent Good Further technical reference and product info can be obtained from associated data sheets Invisible Systems Limited P a g e 15
16 8. Meter Validation To confirm this meter readings will need to be taken at different intervals and entered into the meter validation page on Realtime-Online(tm). Check meter validation(reports>meter Validation) then pick sensor ID that is fitted Enter the reading obtained with date and time > Submit This will need to be done twice as a minimum to allow the Realtime-online software to check the readings. (the longer the time between reading the better the result). An initial check whilst on site can be done with a few hours between readings however for full and accurate calibration, ideally 7 days between readings is desirable (48 hours minimum). Click the two readings entered on the left of the screen and then Compare Readings the system will then work out and validate the readings being taken are correct. If the suggested pulse ratio is significatly diferent to the current Pulse Ratio the amend the Pulse Factor in Sensor setup to help aid in the calibration of the equipment. The more readings taken over time help prove correct operation. Invisible Systems Limited P a g e 16
17 9. Appendix 1 Part Numbers. Part Number Item Description Ultra RF-Modbus Modbus Transmitter 2m PVC Mains Powered Ultra RF Repeater RF Signal Repeater Mains Powered Invisible Systems Limited P a g e 17
Installation Manual Multi Input Temperature Logger QC0163. Manual Ref: QC0163. Version: FEB17 1.0
Installation Manual 3999-913-2252 Multi Input Temperature Logger QC0163 Manual Ref: QC0163 Version: FEB17 1.0 System Concept RF Transmitters connect to sensors or meters and send data to the infrastructure
More informationInstallation Manual. Repeater QC0149. Version: Jan17 1.0
Installation Manual Repeater QC0149 Manual Ref: QC0149 Version: Jan17 1.0 System Concept RF Transmitters connect to sensors or meters and send data to the infrastructure internet connected Gateway on site
More informationInstallation Manual. Ultra RF Analogue Transmitter QC0168. Manual Ref: QC0168. Version: March
Installation Manual Ultra RF Analogue Transmitter QC0168 Manual Ref: QC0168 Version: March 17 1.0 System Concept RF Transmitters connect to sensors or meters and send data to the infrastructure internet
More informationInstallation Manual. Temp Tx-Sensor with Micro switch QC0164. Version: FEB17 1.0
Installation Manual Temp Tx-Sensor with Micro switch QC0164 Manual Ref: QC0164 Version: FEB17 1.0 System Concept RF Transmitters connect to sensors or meters and send data to the infrastructure internet
More informationInstallation Manual. 3 Phase Wireless Meter QC0142. Version: NOV16 1.0
Installation Manual 3 Phase Wireless Meter QC0142 Manual Ref: QC0142 Version: NOV16 1.0 System Concept RF Transmitters connect to sensors or meters and send data to the infrastructure internet connected
More informationModular Metering System ModbusTCP Communications Manual
Modular Metering System Manual Revision 7 Published October 2016 Northern Design Metering Solutions Modular Metering System ModbusTCP 1 Description The multicube modular electricity metering system simultaneously
More informationAcuMesh Wireless RS485 Network. User's Manual SOLUTION
AcuMesh Wireless RS485 Network User's Manual AN SOLUTION ACUMESH - WIRELESS METERING SYSTEM COPYRIGHT 2015 V1.2 This manual may not be altered or reproduced in whole or in part by any means without the
More informationI n s t a l l a t i o n M a n u a l. T E D P r o L i t e A B C. f o r. Shop for The Energy Detective products online at: Rev 3.
Rev 3.5 I n s t a l l a t i o n M a n u a l f o r T E D P r o H o m e T E D P r o L i t e A B C Shop for The Energy Detective products online at: 1.877.766.5412 IMPORTANT: The installation of your TED
More informationWIRELESS MODBUS GATEWAY WGW410
WIRELESS MODBUS GATEWAY WGW410 The Tekon Wireless Modbus Gateway WGW410 is specifically designed to meet the most rigorous requirements of operation in the industrial process environments. Due to their
More informationI n s ta l l at i o n M a n u a l f o r T E D P r o H o m e T E D P r o L i t e A B C Rev 4.0
I n s t a l l a t i o n M a n u a l f o r T E D P r o H o m e T E D P r o L i t e A B C Rev 4.0 IMPORTANT: The installation of your TED Pro Home system is a several-step process. The 1st step is the installation
More informationPM-311x Quick Start Ver PM-311x introduction 1.1. Caution & Warning 1.2. Product Warranty & Customer Support
PM-311x Quick Start Ver. 1.1 1. PM-311x introduction ICP DAS brings the most powerful, cost-effective, advanced Smart Power Meters PM-3000 series that gives you access to real-time electric usage for single-phase
More informationLandis+Gyr. S4e MFMM Cellnet User Manual. Bulletin Revision A. DOCUMENT HISTORY Bulletin:
S4e MFMM Cellnet User Manual Bulletin 051101 Revision A Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted in any form or by any
More informationHANWELL UTILITY DATA SHEET
HANWELL UTILITY DATA SHEET HANWELL UTILITY The Hanwell utility range is an innovative monitoring system that measures and records utility usage over time and allows statistical analysis of kilowatts/hrs,
More informationInstallation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION
Installation and Operation Manual MSI Multi-Sensor Interface Hub Interface Module for all Sensors Network and Wireless CAUTION This equipment complies with the limits for a Class B digital device, pursuant
More informationPanoramic Power System. PAN-10, PAN-12 User Guide
Panoramic Power System Copyright Notice Copyright 2012-2014 Panoramic Power Ltd. All rights reserved. 2 Contents Overview... 4 Workflow... 4 Unpacking the Hardware... 4 Safety Precautions... 5 Hardware
More informationRM24100A. *Maximum transmit power output levels and local radio frequency regulator bodies must be obeyed in the country of operation.
RM24100A 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE 802.15.4 compliant) Operating Manual English 1.02 Introduction The RM24100A radio modem acts as a wireless serial cable replacement and
More informationWIRELESS 868 MHz TEMPERATURE STATION Instruction Manual
WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual INTRODUCTION: Congratulations on purchasing this fancy 868MHz Temperature Station which displays the time, indoor temperature and indoor humidity,
More information2011 / Circuit Tracer
INSTRUCTION MANUAL 2011 / 00521 Circuit Tracer Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. 52044992 2008 Greenlee Textron
More informationRM24100D. Introduction. Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.
RM24100D 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE 802.15.4 compliant) Operating Manual English 1.09 Introduction The RM24100D radio modem acts as a wireless serial cable replacement and
More informationThe wireless alternative to expensive cabling...
The wireless alternative to expensive cabling... ELPRO 105U ISO 9001 Certified New Products... New Solutions The ELPRO 105 range of telemetry modules provide remote monitoring and control by radio or twisted-pair
More informationThe wireless alternative to expensive cabling...
The wireless alternative to expensive cabling... ELPRO 905U Wireless Solutions for Process Applications New Products... New Solutions The ELPRO 905U range of telemetry modules provide remote monitoring
More informationHT1100 Satellite Modem User Guide
HT1100 Satellite Modem User Guide 1039650-0001 Revision C October 11, 2013 11717 Exploration Lane, Germantown, MD 20876 Phone (301) 428-5500 Fax (301) 428-1868/2830 Copyright 2013 Hughes Network Systems,
More informationThe wireless alternative to expensive cabling...
The wireless alternative to expensive cabling... ELPRO 105U Wireless Solutions for Process Applications New Products... New Solutions The ELPRO 105U range of wireless I/O provides a low cost alternative
More informationWIRELESS 868 MHz TEMPERATURE STATION Instruction Manual
WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual INTRODUCTION: Congratulations on purchasing this temperature station with wireless 868 MHz transmission of outdoor temperature and display of indoor
More informationPLUS WGW420 WIRELESS GATEWAY 868MHz
PLUS WGW420 WIRELESS GATEWAY 868MHz REF.: PA164510210 An easy-to-use system that allows wireless reception and transmission of any process variables that could be transformed into an analogue signal. PLUS
More informationKAPPA M. Radio Modem Module. Features. Applications
KAPPA M Radio Modem Module Features Intelligent RF modem module Serial data interface with handshake Host data rates up to 57,600 baud RF Data Rates to 115Kbps Range up to 500m Minimal external components
More informationSPECIAL SPECIFICATION 6744 Spread Spectrum Radio
2004 Specifications CSJ 0924-06-244 SPECIAL SPECIFICATION 6744 Spread Spectrum Radio 1. Description. Furnish and install spread spectrum radio system. 2. Materials. Supply complete manufacturer specifications
More information433 MHZ TEMPERATURE STATION Instruction Manual
433 MHZ TEMPERATURE STATION Instruction Manual INTRODUCTION: Congratulations on purchasing this innovative 433MHz Temperature Station which displays the time with up to the minute indoor and up to three
More informationMultilin DGT. Distributed Generation Trip Control Fast & Wireless Trip of Distributed Generators. Control. Advanced Communications
Multilin DGT Distributed Generation Trip Control Fast & Wireless Trip of Distributed Generators The desire for green power and rapid developments in renewable energy sources are driving the growth of distributed
More informationRev RF Service Tool Operator s Guide
026-1703 Rev 0 7-23-01 RF Service Tool Operator s Guide 1640 Airport Road, Suite 104 Kennesaw, GA 31044 Phone: (770) 425-2724 Fax: (770) 425-9319 ALL RIGHTS RESERVED. The information contained in this
More informationThe wireless alternative to expensive cabling...
The wireless alternative to expensive cabling... ELPRO 905U Wireless Solutions for Process Applications New Products... New Solutions The ELPRO 905U range of wireless I/O provides a low cost alternative
More informationINTELLIMETER REGISTER
INTELLIMETER REGISTER MODEL RG2 INSTALLATION AND CONNECTIONS INSTALLATION MANUAL WARNING: Any work on or near energized metering equipment can present a danger of electrical shock. All work on these products
More informationKENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents
KENCO ENGINEERING COMPANY P.O. BOX 470426, TULSA, OK 74147-0426 PHONE: (918) 663-4406 FAX: (918) 663-4480 http://www.kenco-eng.com e-mail: info@kenco-eng.com KENCO Loop Powered Magnetostrictive Transmitter
More informationUser's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters
User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance
More informationSingle Channel Radio Mic System USER MANUAL. WMU-116-H (Hand Held) WMU-116-B (Belt Pack) Single Channel Radio Mic System
Single Channel Radio Mic System USER MANUAL WMU-116-H (Hand Held) WMU-116-B (Belt Pack) Single Channel Radio Mic System Welcome Thank you for choosing Hill Audio for your sound system. To make sure that
More informationINSTALLATION WARNING: BEFORE COMMENCING INSTALLATION ISOLATE YOUR MAINS ELECTRIC SUPPLY
TT403- K (1000W) Wireless Inline Switch Product Description The TT403- K is a 1000W switchable wireless receiver and can be used to control a lighting system, extractor fan or other appliance. It does
More informationWireless Z-Wave Control ZRP-100US Z-Wave Repeater USER MANUAL. Introduction
Wireless Z-Wave Control ZRP-100US Z-Wave Repeater USER MANUAL Introduction Thank you for choosing ZRP-100 Z-Wave Repeater product! ZRP-100 is a Z-Wave repeater with best RF performance to repeat Z-Wave
More informationInstallation & Operation Manual SAGA1-K Series Industrial Radio Remote Control
Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control Gain Electronic Co. Ltd. Table Of Contents Safety Considerations ------------------------------------------------------------2
More informationMODEL WAVE BRIDGE (ST-97) WIRELESS BRIDGE
MODEL WAVE BRIDGE (ST-97) WIRELESS BRIDGE Warning: Read & understand contents of this manual prior to operation. Failure to do so could result in serious injury or death. PH. 409-986-9800 FAX 409-986-9880
More informationInterface Manual Tank Level Float Stick System
1 Interface Manual Tank Level Float Stick System SignalFire Model: Sentinel-FS-3BIS The SignalFire Sentinel Float Stick Node is an Intrinsically Safe device with the following features: - Standard SignalFire
More informationSTC65 RS485 Modbus. EnOcean Receiver/Transmitter with RS485 Modbus Interface. Data Sheet. Application. Security Advice Caution.
STC65 RS485 Modbus EnOcean Receiver/Transmitter with RS485 Modbus Interface Data Sheet Subject to technical alteration Issue date: 27.06.2014 Application Bidirectional gateway for EnOcean-based sensors
More informationRU210. Dual Multi-UHF Wireless System. Item ref: UK, UK User Manual. Version 1.0
RU210 Dual Multi-UHF Wireless System Item ref: 171.970UK, 171.971UK User Manual Version 1.0 Caution: Please read this manual carefully before operating Damage caused by misuse is not covered by the warranty
More informationD C 01/2019 3
D-0117968-C 01/2019 3 4 D-0117968-C 01/2019 Screw Driver Screw Driver Unplug both the Red & Blue connectors. (see above) Place a small flat head screw driver on the small orange tabs and push down while
More informationMultiCube Multi-Function Electricity Meter. Installation and Operation
MultiCube Multi-Function Electricity Meter Installation and Operation PREFACE MultiCube Operating Guide Revision 1.08 Jan 2007 This manual represents your meter as manufactured at the time of publication.
More informationPRO Professional Radio Control Series Applications
204 205 Ready to Use Remote Control 4, 8/16 Channel Systems Range: Up to 200 metres at 433MHz Up to 1,000 metres at 433MHz NB Relay Outputs: Momentary, Latching, Timed Receiver IP65 Applications Lighting
More information56WM WirelessHART Power Meter SensEnable. Reference Manual Rev 4.0 December 2017
56WM WirelessHART Power Meter SensEnable Reference Manual Rev 4.0 December 2017 56WM WirelessHART Power Meter 56WM Revision 001 HART Device Revision 1.0 Device Description Revision (DD) 1.0 NOTICE This
More informationHAWK5000 Operators Manual
HAWK5000 Operators Manual Keison Products P.O. Box 2124, Chelmsford CM1 3UP, England Tel: +44 (0) 1245 600560 Fax: +44 (0) 1245 600030 Email: sales@keison.co.uk www.keison.co.uk KANE INTERNATIONAL LIMITED
More informationQuick Start Guide. ELPRO 905U-L-T Wireless I/O Transmitter Unit. man_905u-l-t_quickstart_v1.9.doc
Quick Start Guide ELPRO 905U-L-T Wireless I/O Transmitter Unit man_905u-l-t_quickstart_v1.9.doc About this document This document is the and contains the following sections: Section Basic steps for using
More informationFor detailed specifications and ordering info go to
For detailed specifications and ordering info go to www.testequipmentdepot.com ECB50A, ECB50A-E, ECB50A-FGIS Circuit Breaker Finder and AC Cable Tracer User Manual For detailed specifications and ordering
More informationFluke 125. Getting Started. Industrial ScopeMeter
Fluke 125 Industrial ScopeMeter Getting Started GB Dec 2006, Rev. 1, 09/2009 2006, 2009 Fluke Corporation, All rights reserved. Printed in The Netherlands All product names are trademarks of their respective
More informationMODEL 3810/2 Line Impedance Stabilization Network
EMC TEST SYSTEMS FEBRUARY 1996 REV C PN 399197 MODEL 3810/2 Line Impedance Stabilization Network OPERATION MANUAL USA P.O. Box 80589 Austin, Texas 78708-0589 2205 Kramer Lane, Austin, Texas 78758-4047
More informationUser's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters
User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance
More informationFrequently Asked Questions
Frequently Asked Questions This document provides a non-exhaustive collection of some of the questions frequently asked by our customers. What is your system s wireless range? 1 What are the risks of interference
More informationACUMESH - WIRELESS RS485 NETWORK KEY FEATURES ACUMESH - WIRELESS METERING SYSTEM
ACUMESH WIRELESS RS485 NETWORK The AcuMesh wireless metering solution is designed to connect energy meters and any devices by communicating with RS485 wirelessly. AcuMesh is a costeffective solution that
More informationTT W Wireless receiver Inline Switch
TT403 1000W Wireless receiver Inline Switch Product Description The TT403 is a 1000W switchable wireless receiver and can be used to control a lighting system, extractor fan or other appliance. It does
More informationUSER MANUAL Digital Wireless Gateway U9120-W4 (P/N: 44002G-01)
USER MANUAL Digital Wireless Gateway U9120-W4 (P/N: 44002G-01) 19549P-82 (11-16) 2016 DAVID CLARK COMPANY INCORPORATED Cautions and Warnings READ AND SAVE THESE INSTRUCTIONS. Follow the instructions in
More informationGrid Radar Installation Manual
Grid Radar Installation Manual MODELS GN-RD-001 120V Single Phase / Wye, 240V Single Phase, with Neutral GN-RD-002 277V 3-Phase Wye, with Neutral GN-RD-003 480V 3-Phase Delta, no Neutral GN-RD-004 208V
More informationCopyright Teletronics International, Inc. Patent Pending
Copyright 2003 By Teletronics International, Inc. Patent Pending FCC NOTICES Electronic Emission Notice: This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
More informationSpecification Sym Notes Minimum Typical Maximum Units 900 MHz Operating Frequency Range MHz
900 MHz FHSS DNT90/Ethernet Gateway Optional 128-Bit AES Encryption Point-to-point, Point-to-multipoint or Store and Forward Operation 158 mw EIRP 900 MHz Transmitter Power 10/100Base-T Auto-sensing Ethernet
More informationLT3000 ULTRASONIC LEVEL TRANSMITTER
LT3000 ULTRASONIC LEVEL TRANSMITTER Owner s Manual Specifications Installation Calibration Troubleshooting Warranty Drawings Distributed By: iprocessmart.com 14262 Doolittle Drive San Leandro, CA 94577
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS MEMFLO MFT2 2-WIRE FLOW TRANSMITTER (877) 356-5463 (p) 330-331-7331 (f) 330-331-7172 www.flo-corp.com 2017 FLO-CORP REVA 1116 1 DESCRIPTION Please read carefully! No liability can
More informationINSTALLATION GUIDE. Video Balun Transceiver with fixed BNC for twisted pair operation with other balun transceivers or active receivers.
INSTALLATION GUIDE VB37M Video Balun Transceiver for Twisted Pair Description Video Balun Transceiver with fixed BNC for twisted pair operation with other balun transceivers or active receivers. The VB37M
More informationContents. Page English 1. French. Spanish. Reset of MIN/MAX records 915 MHz Reception Mounting Care and Maintenance Warranty Information
Contents Language Page English 1 French Spanish WIRELESS 915 MHz TEMPERATURE STATION Instruction Manual TABLE OF CONTENTS Topic Page Inventory of Contents Features Setting Up Battery Installation Function
More information905U Wireless. New Products... New Solutions. The wireless alternative to expensive cabling... Simple but Reliable. Easy to Use
Wireless New Products... New Solutions The range of telemetry modules provide remote monitoring and control by radio or twisted-pair wire, over short or long distances. Transducer signals connected at
More informationSCADA and Telemetry Solutions. SCADALink IO900. Modular Wireless I/O System. User Manual Version V1.3 for SCADALink IO900 BENTEK SYSTEMS LTD
Modular Wireless I/O System User Manual Version V. for BENTEK SYSTEMS LTD #, 0 Ave S.E. Calgary, AB, Canada TB 0L Ph:(0) Fax:(0) email: sales@scadalink.com web: The is a Modular Wireless I/O System that
More informationSolarEdge Feed-in Limitation Application Note
SolarEdge Feed-in Limitation Application Note Version 1.1 Disclaimers Disclaimers Important Notice Copyright SolarEdge Inc. All rights reserved. No part of this document may be reproduced, stored in a
More informationWireless Interface RAD-ISM-900-SET-BD-BUS Two-way (point-to-point) Monitoring and Control with Expandable I/O Options User Manual
Wireless Interface RAD-ISM-900-SET-BD-BUS Two-way (point-to-point) Monitoring and Control with Expandable I/O Options User Manual ) ) ) ) ) ) ) ) ) ) ) ) Notice: These devices must be wired in accordance
More informationPROFLY / PROBLADE Professional Radio Control PRO-BLADE8
PRO-BLADE8 Ready to Use Remote Control 8 Channel Systems Range: PROFLY Up to 100 metres PROBLADE Up to 500 metres Relay Outputs: Momentary, Latching, Timed Receiver IP65 Applications Lighting Control General
More informationModbus communication module for TCX2: AEX-MOD
Modbus communication module for TCX2: Communication Specification TCX2 is factory installed in TCX2 series controllers with -MOD suffix, and is also available separately upon request for customer installation
More informationInstallation guide 971 SmartRadar LTi
Installation guide 971 SmartRadar LTi March 2009 Part no. 4416.715 Revision 3 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywellenraf.nl
More informationMU110-16R(K) Digital output module 16 channel. User guide
MU110-16R(K) Digital output module 16 channel User guide MU110-16R(K)_2016.12_0220_EN All rights reserved Subject to technical changes and misprints akytec GmbH Vahrenwalder Str. 269 A 30179 Hannover Germany
More informationMounting instruction and operating manual. Access Point (UK) HmIP-HAP-UK
Mounting instruction and operating manual Access Point (UK) HmIP-HAP-UK Package contents Quantity Description 1 Homematic IP Access Point (UK) 1 Plug-in mains adapter 1 Network cable 2 Screws 2 Plugs 1
More informationA Super trainer with advanced hardware and software features only found in very expensive equipment.
PLC Trainer PTS T100 LAB EXPERIMENTS A Super trainer with advanced hardware and software features only found in very expensive equipment. You won t find any similar equipment among our competitors at such
More informationAR-DN-RS232. An-10 / Rapid RS232 Interface. Product Guide. Overview. Features
AR-DN-RS232 An-10 / Rapid RS232 Interface Product Guide Overview The AR-DN-RS232 is a device that is used as a 2 way gateway between third party systems and the CP An-10 or Rapid lighting control systems
More informationEarth Leakage Monitoring System IsoBase IsoHub IsoOut
2014 11 21 Earth Leakage Monitoring System IsoBase IsoHub IsoOut User Manual Due to our policy of continual improvement, specifications may change without prior notice Page 2 (34) Contents Earth Leakage
More informationDJA3000. Cellular Communication Jammer. Installation and Operations Manual. Series DJA3000. Description: Cellular Communication Jammer
DJA3000 Cellular Communication Jammer Installation and Operations Manual Series DJA3000 Description: Cellular Communication Jammer Models: DJA3040 and DJA3120 Series DJA3000 up to 4 Bands Thank you for
More informationDIGITAL AUDIO AMPLIFIER WITH BLUETOOTH. Model: DAA User Manual
DIGITAL AUDIO AMPLIFIER WITH BLUETOOTH Model: DAA User Manual IMPORTANT INSTRUCTIONS When using electrical products, basic precautions should always be followed, including the following: WARNING: Risk
More informationSER8300 Series Terminal Equipment Controller with Optional PIR sensor Installation Guide
Room Controllers Terminal Equipment Controller with Optional PIR sensor Installation Guide Commercial and Hotel/Lodging HVAC Fan Coil Applications 1 CONTENTS Installation 2 Location 2 Installation 2 Terminal,
More informationJBus/Modbus Communication Card
JBus/Modbus Communication Card Installation and Operation 05/2018 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries
More informationC-Bus 8 Channel Low Voltage Relay
SLC5108RELVP Instruction Bulletin Retain for future use. 63249-420-325A1 Instruction Bulletin 07/2009 HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the equipment to
More informationWireless sensor system
Wireless sensor system Internet / Ounet PC in internal network GW Internet connection FIGURE 1 structure of wireless sensor network = Base station = Routing wireless sensor = Wireless sensor General description
More informationiant200 iant212 iant213 iant214 iant215 iant216 iant217 iant218 iant219 iant220 iant221 iant222 Operating Manual iant2xx Series of Antennas
iant200 iant212 iant213 iant214 iant215 iant216 iant217 iant218 iant219 iant220 iant221 iant222 Operating Manual iant2xx Series of Antennas This page is intentionally left blank. Document Number 403449
More informationUplink 5500EZ. Installation and User Guide. S e pte m be r 1 2,
Uplink 5500EZ Installation and User Guide 4 13 464 7 2 S e pte m be r 1 2, 2 01 8 Important Notice Due to the nature of wireless communications, transmission and reception of data can never be guaranteed.
More informationUSB Port Medium Power Wireless Module SV653
USB Port Medium Power Wireless Module SV653 Description SV653 is a high-power USB interface integrated wireless data transmission module, using high-performance Silicon Lab Si4432 RF chip. Low receiver
More informationRM24100A. Introduction. 1 Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.
RM24100A 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE 802.15.4 compliant) Operating Manual English 1.03 Introduction The RM24100A radio modem acts as a wireless serial cable replacement and
More informationDigital Electronic Thermostat With RF
RT300RF Manual Altech 005_89 06/05/2014 08:56 Page 1 Digital Electronic Thermostat With RF Instruction Manual Model No ALTHC015 RT300RF Manual Altech 005_89 06/05/2014 08:56 Page 2 2 ALTHC015 INSTRUCTION
More information433 MHZ REMOTE THERMO
433 MHZ REMOTE THERMO INTRODUCTION: Congratulations on purchasing this innovative 433MHz Remote Thermo which displays the time with up to the minute indoor and up to five outdoor temperature readings.
More informationWS-7136U Wireless 433 MHz Temperature Station. Instruction Manual
WS-7136U Wireless 433 MHz Temperature Station Instruction Manual TABLE OF CONTENTS Topic Page Inventory of Contents 3 Additional Equipment 4 Quick Setup 5-9 Detailed Setup Guide Battery Installation 10-12
More informationRM24100D. Introduction. 1 Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.
RM24100D 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE 802.15.4 compliant) Operating Manual English 1.03 Introduction The RM24100D radio modem acts as a wireless serial cable replacement and
More informationUni-Mux XQL Multi-Channel Data Acquisition Module
Uni-Mux XQL Multi-Channel Data Acquisition Module Uni-Mux XQL Multi-Channel Data Acquisition Module * 8 channel differential inputs. * 16 channel single ended inputs. * User programmable via P.C. software.
More informationModular Radio Telemetry System
Simple to Use Remote Control 8 Channels per Transmitter 16 Channels per Receiver Upto 48 Transmitters per system Auto Transmit Mode Secure RF Protocol Automatic Watchdog Transmission Range: Upto 200 metres
More information4590 Tank Side Monitor. Service Manual. Mark/Space Communication Protocol. Software Version v2.03 SRM009FVAE0808
SRM009FVAE0808 4590 Tank Side Monitor Mark/Space Communication Protocol Service Manual Software Version v2.03 www.varec.com Varec, Inc. 5834 Peachtree Corners East, Norcross (Atlanta), GA 30092 USA Tel:
More informationC33R Repeater. User manual
C33R Repeater User manual Getting to know your Repeater LED INDICATOR STATUS: Off = Power supply is off Red/Blue = In registration mode Blue (Triple flash) = Registration completed successfully Blue (Steady)
More informationisma-b-w0202 Modbus User Manual GC5 Sp. z o.o. Poland, Warsaw
isma-b-w0202 isma-b-w0202 Modbus User Manual GC5 Sp. z o.o. Poland, Warsaw www.gc5.com 1. Introduction... 4 2. Safety rules... 4 3. Technical specifications... 5 4. Dimension... 6 5. LED Indication...
More informationWIRELESS 915 MHz TEMPERATURE STATION Instruction Manual
Contents Language Page English 1 French Spanish TABLE OF CONTENTS WIRELESS 915 MHz TEMPERATURE STATION Instruction Manual Topic Inventory of Contents Features Setting Up Battery Installation Function keys
More informationNano SPY Ref : 11816C
USER GUIDE Nano SPY Ref : 11816C TABLE OF CONTENTS I. INTRODUCTION... 3 a) Product contents... 3 b) Symbols... 3 II. INSTALLATION RECOMMANDATION... 3 a) Sources of disturbances or attenuation... 3 b) Positioning...
More informationOn-Line Cardio Theater Wireless Digital Transmitter Installation and Instruction Manual
On-Line Cardio Theater Wireless Digital Transmitter Installation and Instruction Manual Full installation instructions accompany your Cardio Theater equipment order. This On-Line version of our Installation/Instruction
More informationSPECIAL SPECIFICATION 6574 Low Power Wireless Modem
2004 Specifications CSJ 1068-04-126, etc. SPECIAL SPECIFICATION 6574 Low Power Wireless Modem 1. Description. This work shall consist of furnishing and supplying a Low Power Wireless Modem at the locations
More informationRM868500D. Introduction. Features. 868MHz 500mW RS232 / RS485 / RS422 Radio Modem. Operating Manual English 1.01
RM868500D 868MHz 500mW RS232 / RS485 / RS422 Radio Modem Operating Manual English 1.01 Introduction The RM868500D radio modem acts as a wireless serial cable replacement and can wirelessly connect various
More informationWIRELESS 868 MHz TEMPERATURE STATION Instruction Manual
WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual INTRODUCTION: Congratulations on purchasing this compact 868MHz Temperature Station which displays radio controlled time, date, indoor and outdoor
More information