Filling in the MIMO Matrix Part 2 Time Waveform Replication Tests Using Field Data

Size: px
Start display at page:

Download "Filling in the MIMO Matrix Part 2 Time Waveform Replication Tests Using Field Data"

Transcription

1 Filling in the MIMO Matrix Part 2 Time Waveform Replication Tests Using Field Data Marcos Underwood, Russ Ayres, and Tony Keller, Spectral Dynamics, Inc., San Jose, California There is currently quite a bit of interest in using field data as much as possible for performing multi-shaker laboratory simulations. With the introduction of MIL-STD-810G in 2008, and especially Method 525, Time Waveform Replication, multi-shaker replication tests are being attempted and performed more than ever. As with any multi-exciter test, it is important to characterize the entire test configuration, including shakers, amplifiers, fixtures, transducers and cables before starting the test. To minimize test errors, especially if long time records are being used, system characterization should be updated during the test, perhaps every control loop. Also, even though the purpose of the test is carefully reproducing time waveforms from field measurements, the control process may take place in the time domain, the frequency domain or both. We show here the development of a unique approach to creating and controlling time records with a seamless transition from block to block. Although multi-shaker testing has been attempted for over 40 years, it is only in the past 8 to 10 years that the correct combination of instrumentation, computers and software have become available to make this technique a reality. In the absence of a set of comprehensive multi-exciter test specifications, many organizations have tried to take the advice of MIL-STD-810 and use measured or borrowed field vibration data to create a laboratory simulation. Some recent reports 1,2 have indicated that when using actual measured field vibration for multi-exciter simulation, care must be taken to assure good phase and coherence duplication, or unexpected results may occur. So it is up to the test engineers to assure that they have taken into account or at least considered: Quality of the multi-channel test data to be used for replication Boundary condition differences, field to lab Number and location of lab shakers Test lab fixturing arrangement and possible effect on system dynamics Control approach to be implemented square, rectangular, over-determined, etc. Position and number of control transducers Approach to error analysis for proof of performance Time Waveform Replication As discussed in Reference 3, time waveform replication (TWR) is a vibration control method whose goal is to cause the response time history at one or more control points to agree with a prespecified vector of waveforms while using one or more exciters. TWR control is typically performed at least partially in the frequency domain. But since the main goal of TWR is to recreate a series of time waveforms as closely as possible, its performance is usually evaluated in the time domain. Figure 1 shows an overlay of the Reference and actual Control waveforms present at Control point 3 in the 4 shaker test described here. In this case, the Control was so good that it is very hard to distinguish between the Control (white) and Reference (blue) traces. This figure shows the first 100 milliseconds of the 4-second records that were used. Note that the peak values shown refer to the entire 4-second record. Figure 2 shows an error display in percent of peak value for the same Control location 3, but this time for the entire 4-second record. Note that one point approaches 0.4%, and a second exceeds 0.3%. But for most of the record the peak error never exceeds 0.2%. When performing TWR control, the Reference and Control response time histories are typically longer than an FFT block. So an indirect convolution method using overlap and add is typically used for Control and Drive signal generation. Figure 1. Overlay of Reference and Control waveforms (expanded). Figure 2. Control error as percentage of peak value shown over full 4-second waveform. Figure 3. Test setup for acquiring and controlling field data. TWR Control Approach While in the frequency domain, the product of two spectra or of a spectrum and a frequency response function, can be taken by direct multiplication. Performing an equivalent operation in the time domain, requires the use of convolution. 4,5 The Control approach described here uses indirect linear convolution between the measured inverse impulse response of the system under test and the Reference and Error time histories. The use of overdeter- 8 SOUND & VIBRATION/SEPTEMBER

2 Figure 4. Control PSDs at four plate corners during field data acquisition phase: (a) 1,1; (b) 2,2; (c) 3,3; (d) 4,4. Figure 5. Control coherence and phase for MIMO random test shown in Figure 4: (a&c) 1,2; (b&d) 2,3 DYNAMIC TESTING REFERENCE ISSUE 9

3 Figure 6. Response PSDs at locations: (a) 5, (b) 6, (c) 7 and (d) 8 for Test A. test system includes bolted joints or oil flow, which can change dynamic properties with time, only adaptive control can assure a successful test completion. Figure 7. Four-second Reference and Control waveforms. mined TWR Control is possible with the use of I/O transformations, although this technique was not used in the tests described here. Generally, TWR Control performance is determined by the quality of the system under test and the accuracy of the measured inverse frequency response (impedance) matrix. Adaptive Control Adaptive Control is a patented method [Patent # 5,299,459], that updates the impedance matrix (system model) of virtually every control loop using actual Response and Drive signals. This can minimize the time it takes to match the Reference and Response time histories or spectra. This approach can also be used to update the actual Drive signals in real-time while the test is running to reduce Control errors during a TWR test. Without this capability, Drives are only updated between test sequences or at the start of the test in TWR applications. This approach can simulate and control nonlinear and time-varying environments to a much higher degree of accuracy than using traditional techniques. For example, if the Considerations for using Field Data Before attempting to run any multi-exciter TWR test, it is always good practice to see how good a match there is between the available field data, the goals and objectives of the TWR test and the test facilities at your disposal. At a minimum, the dynamic capabilities of the multi-exciter test system, in terms of load capacity, force rating, bandwidth, acceleration, velocity and displacement capability should match or exceed the test objectives. In addition, the test article s dynamic response characteristics must be compatible with the field data. Is the measured data complete and a good match for the sampling rate and record length parameters of the test control system? Or will resampling be required? Were the field transducers mounted at locations and orientations that will exist and be available in the Lab? Or will the apparatus and fixturing required to mount the test article to the exciters actually eliminate some field measurement locations? Test article dynamic response characteristics must be compatible with the measured field data, and boundary conditions encountered in the field should be satisfied as closely as possible during the lab test. Unless care is taken to understand the dynamic response of the test article when mounted in the test platform configuration, the resulting TWR could be a severe overtest or even an undertest. Using Field Data in a Multi-Exciter TWR Test Test A MIMO Random Control with Zero Coherence Between Control Points. We present several examples of recording field data and using these data to create time waveform records and then to replicate the data on a four-shaker system. In the first example (Test A), the boundary conditions (BC) between the field setup and the test lab simulation are exactly matched. In another case (Test C), they are not matched, but the lab test is still required to 10 SOUND & VIBRATION/SEPTEMBER

4 Figure 8. TWR waveforms with Reference and Control overlaid from Test B: (a) 1; (b) 2; (c) 3; (d) 4. Figure 9. Measured TWR Control error (%) for Test B at locations: (a) 1; (b) 2; (c) 3; (d) 4. reproduce the measured field data. Field data for each case were obtained by exciting an aluminum plate with uncorrelated noise using four shakers and MIMO random control. Response time histories for the selected TWR Control locations were then recorded and used for the subsequent time waveform replication tests. DYNAMIC TESTING REFERENCE ISSUE 11

5 Figure 10. Control PSDs derived from TWR time waveforms of Test B: (a) 1; (b) 2; (c) 3; (d) 4. Figure 11. Response PSDs for Test B at locations: (a) 1; (b) 2; (c) 3; (d) SOUND & VIBRATION/SEPTEMBER

6 Figure 3 shows the test setup for controlling the four corners of a lightly damped plate and measuring four field data Responses at four arbitrary locations inboard from the Control locations. Note that in addition to the eight mounted accelerometers, a loose book was placed on the plate to simulate system time variability during the test. Since the test data used for TWR often exceeded 6 g, quite a bit of book motion was experienced during the TWR test. The first phase of the test controlling the four corners was done at a nominal Control level of 1 g rms. This means that, besides having instantaneous acceleration values at the response points that exceeded 5 g, the corners would sometimes also exceed 1 g. This would cause book motion also during the acquisition phase Figure 12. Nuts loosened toward end of Test B. of getting the field data. The Control PSDs experienced during the first-step MIMO random Control are seen in Figure 4. As can be seen, Control was quite good even in the presence of several resonances; this will be shown later. For Test A, the Control coherence was set to zero. This produces completely random phase relationships between Control locations. The coherence for all six upper off-diagonal matrix terms was controlled to zero, resulting in random phase between all Control points for this incoherent situation. While controlling to these parameters, the response PSDs for the auxiliary points, 5 through 8, were also measured. These are seen in Figure 6. While controlling the four corners of the plate with MIMO random excitation, time histories of the four Response locations, 5 thru 8, were recorded to disk. Since stationary data were being recorded, we decided that 4-second time blocks would be sufficient for performing subsequent TWR tests. This also corresponds to one block of the 200 Hz MIMO random test performed with 800 Control lines. A typical 4-second TWR signal from this test showing both Reference and Control is seen in Figure 7. In Figure 7, the instantaneous accelerations at the TWR Control points can easily exceed 6 or 7 g. Therefore, the nonlinearizing loose book on the plate becomes a critical factor in terms of the need for adaptive Control. Summary, Test A.: MIMO Random Control at locations 1, 2, 3 and 4. Response measurements at locations 5, 6, 7 and 8. Time histories of all channels recorded. Test B TWR Control Using Time Records from Test A. In Figure 8, the four channels of time waveforms collected during Test A and used as the basis of Test B are shown. Different record lengths are shown for each controlled channel to illustrate the excellent overlay between the Reference (desired) and actual Control waveforms. At this point in the testing, the system boundary conditions were considered to be the same for both the MIMO random test when waveforms were recorded and the subsequent TWR test. Figure 9 shows the accuracy achieved in the first TWR test and that most errors are less than 0.2% after a few iterations. The error definition used here is instantaneous Control error normalized to peak acceleration. This is quite a stringent definition, compared Figure 13. Control PSDs for Test C with loosened nuts: (a) 1,1 (b) 2,2; (c) 3,3; (d) 4,4. DYNAMIC TESTING REFERENCE ISSUE 13

7 Figure 14. Resulting Control coherence and phase during Test C: (a) 1,2 coherence; (b) 2,3 coherence; (c) 1,2 phase; (d) 2,3 phase Figure15. Measured Responses taken during Test C: (a) 5; (b) 6; (c) 7; (d) SOUND & VIBRATION/SEPTEMBER

8 Figure 16. Superimposed Control and Reference waveforms from Test D: (a) 1; (b) 2; (c) 3; (d) 4. Figure 17. TWR error displays for Test D: (a) 1; (b) 2; (c) 3; (d) 4. with other techniques often used. Method 525 of MIL-STD-810G does not require a specific formulation to determine TWR error but does offer 14 different approaches to determine how well the TWR test was performed. Some of these different approaches may be described by Ron Merritt in the future. For the four Control points in Test B, locations 5, 6, 7 and 8, DYNAMIC TESTING REFERENCE ISSUE 15

9 Figure 18. PSDs of Control TWR waveforms for Test D: (a) 1; (b) 2; (c) 3; (d) 4. Figure 19. PSDs during TWR of Test D for auxiliary locations: (a) 1; (b) 2; (c) 3; (d) SOUND & VIBRATION/SEPTEMBER

10 power spectral densities were created and are shown in Figure 10. During Test B, locations 1, 2, 3 and 4 (which were the Control points for Test A but are Response locations for Test B) were also analyzed and are shown in Figure 11. Due to reciprocity, the excellent Control results in replicating the Responses at locations 5, 6, 7 and 8 and the nearly linear behavior of the test system, these agree quite well with those shown in Figure 4. Near the end of Test B, it was noted that some unexplained spikes were appearing in the data, especially in the frequency domain representations. An investigation was done, and it was discovered that at the shaker 3 attachment to the plate, the set of attachment nuts had vibrated loose. In effect, this was providing a fifth excitation to the plate but in the form of nonrepetitive shocks. This had the result of exciting the plate resonances to an even higher degree than the random excitation, creating a non-zero coherence with respect to location 3 and introducing a noncontrollable spectrum source. This definitely introduces a sense of realism into an otherwise very clean test. The connection involved here is highlighted in Figure 12. The realization that the single loosened nut added a completely new dynamic into the TWR test led to the creation of additional tests that are described next. Test C MIMO RandomTest Performed with Shaker 3 Attachment Nuts Loosened. The next test performed was done to see the effects of running another controlled MIMO random test, this time with the loose connection at Shaker 3. Figure 13 shows the Control situation for Test C. Note that the Control levels are all very close to 1 g rms. But at the Control location nearest shaker 3, additional spikes, not coming directly from the (linear) shakers are contributing to the measurements. Since these are not linearly related to the complex set of Drive vectors being created, they fall outside the system definition in the spectral density matrix. So the resulting Control coherence is also affected at these spike frequencies (see Figure 14). The Response PSDs of locations 5 thru 8 were also measured during Test C and are shown in Figure 15. In addition to the impacts imparted at shaker 3 during Test C, due to the loosened connection, the lack of a secure tiedown at that location also removed some natural damping imparted by the normally tight connection. This results in a slightly higher Q in the plate responses, as shown in Figure 15. During Test C with the untightened condition at shaker 3, a new set of time waveforms was recorded. This led to Test D. Test D: TWR Test Performed on Retightened Structure Using Waveforms Recorded During Test C. The final test was performed using a set of boundary conditions, (connections tightened at all 4 shakers), which was different from the boundary conditions that existed when the data were taken during Test C. With these different sets of boundary conditions between Test C and Test D, the TWR Control, although quite good, was not as good as that seen during Tests A and B. Examples of the four waveforms replicated during the final test are shown in Figure 16. The poorer boundary condition match in Test D resulted in an increased error during TWR (see Figure 17). But the PSDs measured during the TWR done in Test D (Figure 18), look much more like those of Figure 10 taken during Test B (tight MIMO acquisition, tight TWR control), than those of Figure 15 taken during Test C (loose MIMO acquisition, loose MIMO control). A slight increase in Q is noted, but there are not as many obvious spikes in all four channels as previously. Finally, Figure 19 shows the reciprocity locations 1 thru 4 during the TWR control of Test D; it bears a closer similarity to Figure 11 (no spikes) than Figure 13 (many spikes). Although there are spikes in Figure 19 at the same frequencies as in Figure 13, they are at reduced amplitudes. Conclusions TWR control performance while employing the field Response data discussed here was very good; waveform errors were less than 1% in virtually all cases. Comparing Reference and Control waveforms during TWR testing is an extremely sensitive procedure, much more so than, for example, comparing PSD levels. So extra precautions should be taken to assure that factors such as loose connections or slapping are not present during the test. The use of adaptive Control during TWR testing is very effective in addressing time-varying and nonlinear characteristics in the test setup. Satisfying field boundary conditions in the lab as much as possible may have the largest single effect on assuring a quality laboratory simulation. More work needs to be done on selecting a range of acceptable error metrics when performing TWR tests. However, the point-topoint error comparison used in this article is the most severe. When performing error analysis after a TWR test, it is advantageous to observe results in both the time and the frequency domains. Although our goal is to match the time histories as closely as possible, some results, especially on highly resonant structures, may offer more meaningful comparisons as PSDs. This is evident in Figures 18 and 19. Measuring and comparing noncontrol points in the field and in the lab during TWR tests will help assure a quality TWR simulation. References 1. Lamparelli, Marc, Underwood, Marcos, Ayres, Russell, and Keller, Tony, An Application of ED Shakers to High Kurtosis Replication, ESTECH2009, 55th Annual meeting of the IEST, Schaumburg, IL, May 4-7, Underwood, Marcos, Ayres, Russell, and Keller, Tony, Filling in the MIMO Matrix, Using Measured Data to run a Multi-Actuator/Multi-Axis Vibration Test, presented at the 80th Shock & Vibration Symposium, San Diego, CA, October 26-29, MIL-STD-810G Test Method Standard for Environmental Engineering Considerations and Laboratory Tests, October 31, 2008, Method 525, Time Waveform Replication. 4. Chang, David K., Analysis of Linear Systems, Addison-Wesley, Schwartz, Mischa, Information Transmission, Modulation and Noise, McGraw-Hill Electrical and Electronic Engineering Series, The author may be reached at: kellert@sd-star.com. DYNAMIC TESTING REFERENCE ISSUE 17

Recent System Developments for Multi-Actuator Vibration Control

Recent System Developments for Multi-Actuator Vibration Control Recent System Developments for Multi-Actuator Vibration Control Marcos A. Underwood, Tu tuli Enterprises, San Jose, California Tony Keller, Spectral Dynamics Corporation, San Marcos, California This article

More information

Response spectrum Time history Power Spectral Density, PSD

Response spectrum Time history Power Spectral Density, PSD A description is given of one way to implement an earthquake test where the test severities are specified by time histories. The test is done by using a biaxial computer aided servohydraulic test rig.

More information

IMAC 27 - Orlando, FL Shaker Excitation

IMAC 27 - Orlando, FL Shaker Excitation IMAC 27 - Orlando, FL - 2009 Peter Avitabile UMASS Lowell Marco Peres The Modal Shop 1 Dr. Peter Avitabile Objectives of this lecture: Overview some shaker excitation techniques commonly employed in modal

More information

ME scope Application Note 01 The FFT, Leakage, and Windowing

ME scope Application Note 01 The FFT, Leakage, and Windowing INTRODUCTION ME scope Application Note 01 The FFT, Leakage, and Windowing NOTE: The steps in this Application Note can be duplicated using any Package that includes the VES-3600 Advanced Signal Processing

More information

MULTIPLE INPUT MULTIPLE OUTPUT (MIMO) VIBRATION CONTROL SYSTEM

MULTIPLE INPUT MULTIPLE OUTPUT (MIMO) VIBRATION CONTROL SYSTEM MULTIPLE INPUT MULTIPLE OUTPUT (MIMO) VIBRATION CONTROL SYSTEM WWW.CRYSTALINSTRUMENTS.COM MIMO Vibration Control Overview MIMO Testing has gained a huge momentum in the past decade with the development

More information

How to implement SRS test without data measured?

How to implement SRS test without data measured? How to implement SRS test without data measured? --according to MIL-STD-810G method 516.6 procedure I Purpose of Shock Test Shock tests are performed to: a. provide a degree of confidence that materiel

More information

Simulate and Stimulate

Simulate and Stimulate Simulate and Stimulate Creating a versatile 6 DoF vibration test system Team Corporation September 2002 Historical Testing Techniques and Limitations Vibration testing, whether employing a sinusoidal input,

More information

ME scope Application Note 02 Waveform Integration & Differentiation

ME scope Application Note 02 Waveform Integration & Differentiation ME scope Application Note 02 Waveform Integration & Differentiation The steps in this Application Note can be duplicated using any ME scope Package that includes the VES-3600 Advanced Signal Processing

More information

MIL-STD-202G SHOCK (SPECIFIED PULSE)

MIL-STD-202G SHOCK (SPECIFIED PULSE) SHOCK (SPECIFIED PULSE) 1. PURPOSE. This test is conducted for the purpose of determining the suitability of component parts and subassemblies of electrical and electronic components when subjected to

More information

Development of Random Vibration Profiles for Test Deployers to Simulate the Dynamic Environment in the Poly-Picosatellite Orbital Deployer

Development of Random Vibration Profiles for Test Deployers to Simulate the Dynamic Environment in the Poly-Picosatellite Orbital Deployer Development of Random Vibration Profiles for Test Deployers to Simulate the Dynamic Environment in the Poly-Picosatellite Orbital Deployer Steve Furger California Polytechnic State University, San Luis

More information

A practical guide to using MIMO vibration control for MIL-STD-810 single axis transport testing. of large, resonant land based military payloads

A practical guide to using MIMO vibration control for MIL-STD-810 single axis transport testing. of large, resonant land based military payloads A practical guide to using MIMO vibration control for MIL-STD-810 single axis transport testing of large, resonant land based military payloads (First issued at ESTECH 2014 Conference) Claire Flynn MEng

More information

Testing Sensors & Actors Using Digital Oscilloscopes

Testing Sensors & Actors Using Digital Oscilloscopes Testing Sensors & Actors Using Digital Oscilloscopes APPLICATION BRIEF February 14, 2012 Dr. Michael Lauterbach & Arthur Pini Summary Sensors and actors are used in a wide variety of electronic products

More information

ME scopeves Application Note #21 Calculating Responses of MIMO Systems to Multiple Forces

ME scopeves Application Note #21 Calculating Responses of MIMO Systems to Multiple Forces ME scopeves Application Note #21 Calculating Responses of MIMO Systems to Multiple Forces INTRODUCTION Driving forces and response motions of a vibrating structure are related in a very straightforward

More information

Figure 1: The Penobscot Narrows Bridge in Maine, U.S.A. Figure 2: Arrangement of stay cables tested

Figure 1: The Penobscot Narrows Bridge in Maine, U.S.A. Figure 2: Arrangement of stay cables tested Figure 1: The Penobscot Narrows Bridge in Maine, U.S.A. Figure 2: Arrangement of stay cables tested EXPERIMENTAL SETUP AND PROCEDURES Dynamic testing was performed in two phases. The first phase took place

More information

How to perform transfer path analysis

How to perform transfer path analysis Siemens PLM Software How to perform transfer path analysis How are transfer paths measured To create a TPA model the global system has to be divided into an active and a passive part, the former containing

More information

Separation of Sine and Random Com ponents from Vibration Measurements

Separation of Sine and Random Com ponents from Vibration Measurements Separation of Sine and Random Com ponents from Vibration Measurements Charlie Engelhardt, Mary Baker, Andy Mouron, and Håvard Vold, ATA Engineering, Inc., San Diego, California Defining sine and random

More information

Structural Dynamics Measurements Mark H. Richardson Vibrant Technology, Inc. Jamestown, CA 95327

Structural Dynamics Measurements Mark H. Richardson Vibrant Technology, Inc. Jamestown, CA 95327 Structural Dynamics Measurements Mark H. Richardson Vibrant Technology, Inc. Jamestown, CA 95327 Introduction In this paper, the term structural dynamics measurements will more specifically mean the measurement

More information

An Introduction to Time Waveform Analysis

An Introduction to Time Waveform Analysis An Introduction to Time Waveform Analysis Timothy A Dunton, Universal Technologies Inc. Abstract In recent years there has been a resurgence in the use of time waveform analysis techniques. Condition monitoring

More information

Texas Components - Data Sheet. The TX53G1 is an extremely rugged, low distortion, wide dynamic range sensor. suspending Fluid.

Texas Components - Data Sheet. The TX53G1 is an extremely rugged, low distortion, wide dynamic range sensor. suspending Fluid. Texas Components - Data Sheet AN004 REV A 08/30/99 DESCRIPTION and CHARACTERISTICS of the TX53G1 HIGH PERFORMANCE GEOPHONE The TX53G1 is an extremely rugged, low distortion, wide dynamic range sensor.

More information

Experimental Modal Analysis of an Automobile Tire

Experimental Modal Analysis of an Automobile Tire Experimental Modal Analysis of an Automobile Tire J.H.A.M. Vervoort Report No. DCT 2007.084 Bachelor final project Coach: Dr. Ir. I. Lopez Arteaga Supervisor: Prof. Dr. Ir. H. Nijmeijer Eindhoven University

More information

Transfer Function (TRF)

Transfer Function (TRF) (TRF) Module of the KLIPPEL R&D SYSTEM S7 FEATURES Combines linear and nonlinear measurements Provides impulse response and energy-time curve (ETC) Measures linear transfer function and harmonic distortions

More information

Vibration Fundamentals Training System

Vibration Fundamentals Training System Vibration Fundamentals Training System Hands-On Turnkey System for Teaching Vibration Fundamentals An Ideal Tool for Optimizing Your Vibration Class Curriculum The Vibration Fundamentals Training System

More information

Advanced High-Frequency 6-DOF Vibration Testing Using the Tensor System

Advanced High-Frequency 6-DOF Vibration Testing Using the Tensor System Advanced High-Frequency 6-DOF Vibration Testing Using the Tensor System Joel Hoksbergen, Team Corporation 1 Abstract Commercially available vibration test systems able to reproduce and accurately control

More information

A Comparison of MIMO-FRF Excitation/Averaging Techniques on Heavily and Lightly Damped Structures

A Comparison of MIMO-FRF Excitation/Averaging Techniques on Heavily and Lightly Damped Structures A Comparison of MIMO-FRF Excitation/Averaging Techniques on Heavily and Lightly Damped Structures Allyn W. Phillips, PhD Andrew T. Zucker Randall J. Allemang, PhD Research Assistant Professor Research

More information

EIA STANDARD TP-27B. Mechanical Shock (Specified Pulse) Test Procedure for Electrical Connectors EIA B ELECTRONIC INDUSTRIES ASSOCIATION

EIA STANDARD TP-27B. Mechanical Shock (Specified Pulse) Test Procedure for Electrical Connectors EIA B ELECTRONIC INDUSTRIES ASSOCIATION ANSI/-1996 Approved: April 17, 1996 EIA STANDARD TP-27B Mechanical Shock (Specified Pulse) Test Procedure for Electrical Connectors (Revision of EIA-364-27A) MAY 1996 ELECTRONIC INDUSTRIES ASSOCIATION

More information

Quartz Lock Loop (QLL) For Robust GNSS Operation in High Vibration Environments

Quartz Lock Loop (QLL) For Robust GNSS Operation in High Vibration Environments Quartz Lock Loop (QLL) For Robust GNSS Operation in High Vibration Environments A Topcon white paper written by Doug Langen Topcon Positioning Systems, Inc. 7400 National Drive Livermore, CA 94550 USA

More information

3.0 Apparatus. 3.1 Excitation System

3.0 Apparatus. 3.1 Excitation System 3.0 Apparatus The individual hardware components required for the GVT (Ground Vibration Test) are broken into four categories: excitation system, test-structure system, measurement system, and data acquisition

More information

Modal Parameter Estimation Using Acoustic Modal Analysis

Modal Parameter Estimation Using Acoustic Modal Analysis Proceedings of the IMAC-XXVIII February 1 4, 2010, Jacksonville, Florida USA 2010 Society for Experimental Mechanics Inc. Modal Parameter Estimation Using Acoustic Modal Analysis W. Elwali, H. Satakopan,

More information

An Alternative to Pyrotechnic Testing For Shock Identification

An Alternative to Pyrotechnic Testing For Shock Identification An Alternative to Pyrotechnic Testing For Shock Identification J. J. Titulaer B. R. Allen J. R. Maly CSA Engineering, Inc. 2565 Leghorn Street Mountain View, CA 94043 ABSTRACT The ability to produce a

More information

A METHOD FOR OPTIMAL RECONSTRUCTION OF VELOCITY RESPONSE USING EXPERIMENTAL DISPLACEMENT AND ACCELERATION SIGNALS

A METHOD FOR OPTIMAL RECONSTRUCTION OF VELOCITY RESPONSE USING EXPERIMENTAL DISPLACEMENT AND ACCELERATION SIGNALS ICSV14 Cairns Australia 9-12 July, 27 A METHOD FOR OPTIMAL RECONSTRUCTION OF VELOCITY RESPONSE USING EXPERIMENTAL DISPLACEMENT AND ACCELERATION SIGNALS Gareth J. Bennett 1 *, José Antunes 2, John A. Fitzpatrick

More information

New Features of IEEE Std Digitizing Waveform Recorders

New Features of IEEE Std Digitizing Waveform Recorders New Features of IEEE Std 1057-2007 Digitizing Waveform Recorders William B. Boyer 1, Thomas E. Linnenbrink 2, Jerome Blair 3, 1 Chair, Subcommittee on Digital Waveform Recorders Sandia National Laboratories

More information

Hybrid Shaker Technology for Wide-band Vibration Test Systems

Hybrid Shaker Technology for Wide-band Vibration Test Systems Hybrid Shaker Technology for Wide-band Vibration Test Systems Mr. Katsuhiko Nakamura 1, Mr. Kazuyoshi Ueno 1 Dr. John Goodfellow 2 1 IMV Corporation, R&D Centre, 2-6-10 Take-jima, Nishi-yodogawa-ku, Osaka,

More information

Resonance Tube Lab 9

Resonance Tube Lab 9 HB 03-30-01 Resonance Tube Lab 9 1 Resonance Tube Lab 9 Equipment SWS, complete resonance tube (tube, piston assembly, speaker stand, piston stand, mike with adaptors, channel), voltage sensor, 1.5 m leads

More information

DS-2000 Series Measurement of Frequency Response Function

DS-2000 Series Measurement of Frequency Response Function DS-2000 Series Measurement of Frequency Response Function ONO SOKKI CO., LTD. Contents 1. Flow Chart to Measurement 2. Device Connections 3. DS-2000 Setup 4. Measurement 1. Flow Chart to Measurement The

More information

Mechanically Isolated & Electrically Filtered ICP pyroshock Accelerometers. Bob Metz October 2015

Mechanically Isolated & Electrically Filtered ICP pyroshock Accelerometers. Bob Metz October 2015 Mechanically Isolated & Electrically Filtered ICP pyroshock Accelerometers Bob Metz October 2015 Agenda Pyroshock Mechanically isolated shock sensor design MIL-STD-810G, Change Notice 1 calibration criteria

More information

The ENDEVCO high-g shock triaxial accelerometer: A smaller, more cost-effective solution to making triaxial measurements. Endevco technical paper 334

The ENDEVCO high-g shock triaxial accelerometer: A smaller, more cost-effective solution to making triaxial measurements. Endevco technical paper 334 The ENDEVCO high-g shock triaxial accelerometer: A smaller, more cost-effective solution to making triaxial measurements Endevco technical paper 334 New VC accelerometer technology for flight test offers

More information

PC1141 Physics I. Speed of Sound. Traveling waves of speed v, frequency f and wavelength λ are described by

PC1141 Physics I. Speed of Sound. Traveling waves of speed v, frequency f and wavelength λ are described by PC1141 Physics I Speed of Sound 1 Objectives Determination of several frequencies of the signal generator at which resonance occur in the closed and open resonance tube respectively. Determination of the

More information

Resonance Tube. 1 Purpose. 2 Theory. 2.1 Air As A Spring. 2.2 Traveling Sound Waves in Air

Resonance Tube. 1 Purpose. 2 Theory. 2.1 Air As A Spring. 2.2 Traveling Sound Waves in Air Resonance Tube Equipment Capstone, complete resonance tube (tube, piston assembly, speaker stand, piston stand, mike with adapters, channel), voltage sensor, 1.5 m leads (2), (room) thermometer, flat rubber

More information

(i) Sine sweep (ii) Sine beat (iii) Time history (iv) Continuous sine

(i) Sine sweep (ii) Sine beat (iii) Time history (iv) Continuous sine A description is given of one way to implement an earthquake test where the test severities are specified by the sine-beat method. The test is done by using a biaxial computer aided servohydraulic test

More information

Testing in a Combined Vibration and Acceleration Environment

Testing in a Combined Vibration and Acceleration Environment Testing in a Combined Vibration and Acceleration Environment Richard Jepsen and Edward Romero Mechanical Environments Department, MS 1135 Sandia National Laboratories, PO Box 5800 Albuquerque, NM 87185

More information

m+p VibControl Shock Control

m+p VibControl Shock Control www.mpihome.com m+p VibControl Shock Control m+p VibControl is m+p international s proven software for carrying out a wide variety of vibration tests. Shock testing simulates an extreme event that a unit

More information

EWGAE 2010 Vienna, 8th to 10th September

EWGAE 2010 Vienna, 8th to 10th September EWGAE 2010 Vienna, 8th to 10th September Frequencies and Amplitudes of AE Signals in a Plate as a Function of Source Rise Time M. A. HAMSTAD University of Denver, Department of Mechanical and Materials

More information

Experimental Evaluation of Techniques Designed to Reduce Vibration Simulation Test Time

Experimental Evaluation of Techniques Designed to Reduce Vibration Simulation Test Time Journal of Applied Packaging Research Volume 6 Number 2 Article 1 2014 Experimental Evaluation of Techniques Designed to Reduce Vibration Simulation Test Time Kyle Dunno Clemson University, kdunno@clemson.edu

More information

AGN 008 Vibration DESCRIPTION. Cummins Generator Technologies manufacture ac generators (alternators) to ensure compliance with BS 5000, Part 3.

AGN 008 Vibration DESCRIPTION. Cummins Generator Technologies manufacture ac generators (alternators) to ensure compliance with BS 5000, Part 3. Application Guidance Notes: Technical Information from Cummins Generator Technologies AGN 008 Vibration DESCRIPTION Cummins Generator Technologies manufacture ac generators (alternators) to ensure compliance

More information

DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD 213, SHOCK (SPECIFIED PULSE)

DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD 213, SHOCK (SPECIFIED PULSE) INCH-POUND MIL-STD-202-213 18 April 2015 SUPERSEDING MIL-STD-202G w/change 2 (IN PART) 28 June 2013 (see 6.1) DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD 213, SHOCK (SPECIFIED PULSE) AMSC N/A FSC

More information

AN5E Application Note

AN5E Application Note Metra utilizes for factory calibration a modern PC based calibration system. The calibration procedure is based on a transfer standard which is regularly sent to Physikalisch-Technische Bundesanstalt (PTB)

More information

FFT Use in NI DIAdem

FFT Use in NI DIAdem FFT Use in NI DIAdem Contents What You Always Wanted to Know About FFT... FFT Basics A Simple Example 3 FFT under Scrutiny 4 FFT with Many Interpolation Points 4 An Exact Result Transient Signals Typical

More information

VOLD-KALMAN ORDER TRACKING FILTERING IN ROTATING MACHINERY

VOLD-KALMAN ORDER TRACKING FILTERING IN ROTATING MACHINERY TŮMA, J. GEARBOX NOISE AND VIBRATION TESTING. IN 5 TH SCHOOL ON NOISE AND VIBRATION CONTROL METHODS, KRYNICA, POLAND. 1 ST ED. KRAKOW : AGH, MAY 23-26, 2001. PP. 143-146. ISBN 80-7099-510-6. VOLD-KALMAN

More information

6.555 Lab1: The Electrocardiogram

6.555 Lab1: The Electrocardiogram 6.555 Lab1: The Electrocardiogram Tony Hyun Kim Spring 11 1 Data acquisition Question 1: Draw a block diagram to illustrate how the data was acquired. The EKG signal discussed in this report was recorded

More information

Excitation Techniques Do s and Don ts

Excitation Techniques Do s and Don ts Peter Avitabile UMASS Lowell Excitation Techniques Do s and Don ts Marco Peres The Modal Shop 1 Dr. Peter Avitabile Excitation Considerations Objectives of this lecture: Overview impact testing considerations

More information

m+p VibControl Sine Vibration Control

m+p VibControl Sine Vibration Control www.mpihome.com m+p VibControl Sine Vibration Control m+p VibControl is m+p international s proven software for carrying out a wide variety of vibration tests. Its Sine control mode is one of the basic

More information

9th National Congress on Theoretical and Applied Mechanics, Brussels, 9-10 May 2012

9th National Congress on Theoretical and Applied Mechanics, Brussels, 9-10 May 2012 Random Vibration Testing Using a Pseudo-Random Method with Crest-Factor Limiting: An experimental comparison with the classical method J. MARTINO, ir. 1 1, K. HARRI, dr. ir. 2 1 1 Royal Military Academy,

More information

Resonance Tube. 1 Purpose. 2 Theory. 2.1 Air As A Spring. 2.2 Traveling Sound Waves in Air

Resonance Tube. 1 Purpose. 2 Theory. 2.1 Air As A Spring. 2.2 Traveling Sound Waves in Air Resonance Tube Equipment Capstone, complete resonance tube (tube, piston assembly, speaker stand, piston stand, mike with adaptors, channel), voltage sensor, 1.5 m leads (2), (room) thermometer, flat rubber

More information

Module 4 TEST SYSTEM Part 2. SHAKING TABLE CONTROLLER ASSOCIATED SOFTWARES Dr. J.C. QUEVAL, CEA/Saclay

Module 4 TEST SYSTEM Part 2. SHAKING TABLE CONTROLLER ASSOCIATED SOFTWARES Dr. J.C. QUEVAL, CEA/Saclay Module 4 TEST SYSTEM Part 2 SHAKING TABLE CONTROLLER ASSOCIATED SOFTWARES Dr. J.C. QUEVAL, CEA/Saclay DEN/DM2S/SEMT/EMSI 11/03/2010 1 2 Electronic command Basic closed loop control The basic closed loop

More information

Proven Sensor Performance for Emerging Shock Environments

Proven Sensor Performance for Emerging Shock Environments Proven Sensor Performance for Emerging Shock Environments Vesta I. Bateman, Mechanical Shock Consulting, Albuquerque, New Mexico James Letterneau, Meggitt Sensing Systems, Orange County, California There

More information

A Custom Vibration Test Fixture Using a Subwoofer

A Custom Vibration Test Fixture Using a Subwoofer Paper 068, ENT 205 A Custom Vibration Test Fixture Using a Subwoofer Dale H. Litwhiler Penn State University dale.litwhiler@psu.edu Abstract There are many engineering applications for a source of controlled

More information

Vibration Tests: a Brief Historical Background

Vibration Tests: a Brief Historical Background Sinusoidal Vibration: Second Edition - Volume 1 Christian Lalanne Copyright 0 2009, ISTE Ltd Vibration Tests: a Brief Historical Background The first studies on shocks and vibrations were carried out at

More information

SHOCK AND VIBRATION RESPONSE SPECTRA COURSE Unit 4. Random Vibration Characteristics. By Tom Irvine

SHOCK AND VIBRATION RESPONSE SPECTRA COURSE Unit 4. Random Vibration Characteristics. By Tom Irvine SHOCK AND VIBRATION RESPONSE SPECTRA COURSE Unit 4. Random Vibration Characteristics By Tom Irvine Introduction Random Forcing Function and Response Consider a turbulent airflow passing over an aircraft

More information

Earthquake Resistance Test Specifications for Communications Equipment

Earthquake Resistance Test Specifications for Communications Equipment Earthquake Resistance Test Specifications for Communications Equipment (Edition: March 2018) NTT DOCOMO, INC. All rights reserved. TABLE OF CONTENTS 1. INTRODUCTION...1 2. EQUIPMENT TO BE TESTED...1 3.

More information

Real-Time FFT Analyser - Functional Specification

Real-Time FFT Analyser - Functional Specification Real-Time FFT Analyser - Functional Specification Input: Number of input channels 2 Input voltage ranges ±10 mv to ±10 V in a 1-2 - 5 sequence Autorange Pre-acquisition automatic selection of full-scale

More information

Vibration Transducer Calibration System

Vibration Transducer Calibration System 1 Overview UCON is designed for calibrating sensitivity, frequency response characteristic and amplitude linearity of acceleration transducer. There are three basic operation modes for the calibration

More information

System Inputs, Physical Modeling, and Time & Frequency Domains

System Inputs, Physical Modeling, and Time & Frequency Domains System Inputs, Physical Modeling, and Time & Frequency Domains There are three topics that require more discussion at this point of our study. They are: Classification of System Inputs, Physical Modeling,

More information

An Overview of MIMO-FRF Excitation/Averaging Techniques

An Overview of MIMO-FRF Excitation/Averaging Techniques An Overview of MIMO-FRF Excitation/Averaging Techniques Allyn W. Phillips, PhD, Research Assistant Professor Randall J. Allemang, PhD, Professor Andrew T. Zucker, Research Assistant University of Cincinnati

More information

VIBRATION ANALYZER. Vibration Analyzer VA-12

VIBRATION ANALYZER. Vibration Analyzer VA-12 VIBRATION ANALYZER Vibration Analyzer VA-12 Portable vibration analyzer for Equipment Diagnosis and On-site Measurements Vibration Meter VA-12 With FFT analysis function Piezoelectric Accelerometer PV-57with

More information

Active Vibration Isolation of an Unbalanced Machine Tool Spindle

Active Vibration Isolation of an Unbalanced Machine Tool Spindle Active Vibration Isolation of an Unbalanced Machine Tool Spindle David. J. Hopkins, Paul Geraghty Lawrence Livermore National Laboratory 7000 East Ave, MS/L-792, Livermore, CA. 94550 Abstract Proper configurations

More information

Laboratory 14. Lab 14. Vibration Measurement With an Accelerometer

Laboratory 14. Lab 14. Vibration Measurement With an Accelerometer Laboratory 14 Vibration Measurement With an Accelerometer Required Special Equipment: custom-made apparatus consisting of two sets of motors/shafts/bearings mounted on an aluminum plate Endevco 2721B charge

More information

IADS Frequency Analysis FAQ ( Updated: March 2009 )

IADS Frequency Analysis FAQ ( Updated: March 2009 ) IADS Frequency Analysis FAQ ( Updated: March 2009 ) * Note - This Document references two data set archives that have been uploaded to the IADS Google group available in the Files area called; IADS Frequency

More information

The Shocking Truth About the Frequency Domain

The Shocking Truth About the Frequency Domain The Shocking Truth About the Frequency Domain Presenter Herb Schueneman Founder, Board Chairman Moderator Edmund Tang Lab Manager, CPLP Professional September 2017 Herb s Bio 1940 s; starting out 1950

More information

CHAPTER 5 FAULT DIAGNOSIS OF ROTATING SHAFT WITH SHAFT MISALIGNMENT

CHAPTER 5 FAULT DIAGNOSIS OF ROTATING SHAFT WITH SHAFT MISALIGNMENT 66 CHAPTER 5 FAULT DIAGNOSIS OF ROTATING SHAFT WITH SHAFT MISALIGNMENT 5.1 INTRODUCTION The problem of misalignment encountered in rotating machinery is of great concern to designers and maintenance engineers.

More information

CHAPTER 4 IMPLEMENTATION OF ADALINE IN MATLAB

CHAPTER 4 IMPLEMENTATION OF ADALINE IN MATLAB 52 CHAPTER 4 IMPLEMENTATION OF ADALINE IN MATLAB 4.1 INTRODUCTION The ADALINE is implemented in MATLAB environment running on a PC. One hundred data samples are acquired from a single cycle of load current

More information

26 Endevco Isotron accelerometers

26 Endevco Isotron accelerometers Isotron accelerometers Typical applications > Aircraft flight testing > Ground vibration testing > Automotive ride quality testing > Product testing > Quality assurance > Research and development > Test

More information

Summary. Theory. Introduction

Summary. Theory. Introduction round motion through geophones and MEMS accelerometers: sensor comparison in theory modeling and field data Michael Hons* Robert Stewart Don Lawton and Malcolm Bertram CREWES ProjectUniversity of Calgary

More information

CHAPTER 6 INTRODUCTION TO SYSTEM IDENTIFICATION

CHAPTER 6 INTRODUCTION TO SYSTEM IDENTIFICATION CHAPTER 6 INTRODUCTION TO SYSTEM IDENTIFICATION Broadly speaking, system identification is the art and science of using measurements obtained from a system to characterize the system. The characterization

More information

Laboratory Experiment #2 Frequency Response Measurements

Laboratory Experiment #2 Frequency Response Measurements J.B.Francis College of Engineering Mechanical Engineering Department 22-403 Laboratory Experiment #2 Frequency Response Measurements Introduction It is known from dynamic systems that a structure temporarily

More information

Good Modal Practices

Good Modal Practices Good Modal Practices 92-315 Introduction Transducer Considerations Proper Excitation Ensuring Data Gathered is Good Post Processing Tips and Tricks Wrap Up Dr. C. Novak University of Windsor Good Modal

More information

Sampling and Reconstruction

Sampling and Reconstruction Experiment 10 Sampling and Reconstruction In this experiment we shall learn how an analog signal can be sampled in the time domain and then how the same samples can be used to reconstruct the original

More information

DETERMINATION OF CUTTING FORCES USING A FLEXURE-BASED DYNAMOMETER: DECONVOLUTION OF STRUCTURAL DYNAMICS USING THE FREQUENCY RESPONSE FUNCTION

DETERMINATION OF CUTTING FORCES USING A FLEXURE-BASED DYNAMOMETER: DECONVOLUTION OF STRUCTURAL DYNAMICS USING THE FREQUENCY RESPONSE FUNCTION DETERMINATION OF CUTTING FORCES USING A FLEXURE-BASED DYNAMOMETER: DECONVOLUTION OF STRUCTURAL DYNAMICS USING THE FREQUENCY RESPONSE FUNCTION Michael F. Gomez and Tony L. Schmitz Department of Mechanical

More information

Laboratory Experiment #1 Introduction to Spectral Analysis

Laboratory Experiment #1 Introduction to Spectral Analysis J.B.Francis College of Engineering Mechanical Engineering Department 22-403 Laboratory Experiment #1 Introduction to Spectral Analysis Introduction The quantification of electrical energy can be accomplished

More information

Detection and characterization of oscillatory transient using Spectral Kurtosis

Detection and characterization of oscillatory transient using Spectral Kurtosis Detection and characterization of oscillatory transient using Spectral Kurtosis Jose Maria Sierra-Fernandez 1, Juan José González de la Rosa 1, Agustín Agüera-Pérez 1, José Carlos Palomares-Salas 1 1 Research

More information

SHAKER TABLE SEISMIC TESTING OF EQUIPMENT USING HISTORICAL STRONG MOTION DATA SCALED TO SATISFY A SHOCK RESPONSE SPECTRUM Revision C

SHAKER TABLE SEISMIC TESTING OF EQUIPMENT USING HISTORICAL STRONG MOTION DATA SCALED TO SATISFY A SHOCK RESPONSE SPECTRUM Revision C SHAKER TABLE SEISMIC TESTING OF EQUIPMENT USING HISTORICAL STRONG MOTION DATA SCALED TO SATISFY A SHOCK RESPONSE SPECTRUM Revision C By Tom Irvine Email: tom@vibrationdata.com March 12, 2015 The purpose

More information

The rapid evolution of

The rapid evolution of Shock Testing Miniaturized Products by George Henderson, GHI Systems Smaller product designs mandate changes in test systems and analysis methods. Don t be shocked by the changes. Figure 1. Linear Shock

More information

Correlating HALT & HASS, RS/HALT Vibration and End-Use Environments

Correlating HALT & HASS, RS/HALT Vibration and End-Use Environments Correlating HALT & HASS, RS/HALT Vibration and End-Use Environments Stephen A. Smithson, Smithson & Associates, Edina, Minnesota Overcoming decades of shortcomings, applying a fatigue damage spectrum (FDS)

More information

ACE. SignalCalc. Ultra-Portable, Cost-Effective Dynamic Signal Analyzer. 4 input channels, 2 sources. High Speed Tachometer. 120 db dynamic range

ACE. SignalCalc. Ultra-Portable, Cost-Effective Dynamic Signal Analyzer. 4 input channels, 2 sources. High Speed Tachometer. 120 db dynamic range Ultra-Portable, Cost-Effective Dynamic Signal Analyzer SignalCalc ACE 4 input channels, 2 sources High Speed Tachometer 120 db dynamic range SignalCalc Dynamic Signal Analyzers 40 khz realtime bandwidth

More information

A Friendly Approach to Increasing the Frequency Response of Piezoelectric Generators

A Friendly Approach to Increasing the Frequency Response of Piezoelectric Generators A Friendly Approach to Increasing the Frequency Response of Piezoelectric Generators Sam Ben-Yaakov, Gil Hadar, Amit Shainkopf and Natan Krihely Power Electronics Laboratory, Department of Electrical and

More information

2015 HBM ncode Products User Group Meeting

2015 HBM ncode Products User Group Meeting March 4-5, 2015 Livonia, MI (USA) March 4-5, 2015 Livonia, MI (USA) GlyphWorks Accelerated Testing: Not Just for Developing PSD Based Shaker Profiles Presented By Phil Korth Technical Staff Engineer Harley-Davidson

More information

Summary. Seismic vibrators are the preferred sources for land seismic ( ) (1) Unfortunately, due to the mechanical and

Summary. Seismic vibrators are the preferred sources for land seismic ( ) (1) Unfortunately, due to the mechanical and Timothy Dean*, John Quigley, Scott MacDonald, and Colin Readman, WesternGeco. Summary Seismic vibrators are the preferred sources for land seismic surveys. Unfortunately, due to the mechanical and hydraulic

More information

Introduction*to*Machinery*Vibration*Sheet*Answer* Chapter*1:*Vibrations*Sources*and*Uses*

Introduction*to*Machinery*Vibration*Sheet*Answer* Chapter*1:*Vibrations*Sources*and*Uses* IntroductiontoMachineryVibrationSheetAnswer Chapter1:VibrationsSourcesandUses 1. 1. imposed motions related to the function - e.g. slider crank and earn 2. inadequate design - e.g. resonance 3. manufacturing

More information

Proposal. Analysis of Parallel Vibration Paths with Potential Application to Vehicle Noise. Reduction. Submitted to. The Engineering Honors Committee

Proposal. Analysis of Parallel Vibration Paths with Potential Application to Vehicle Noise. Reduction. Submitted to. The Engineering Honors Committee Proposal Analysis of Parallel Vibration Paths with Potential Application to Vehicle Noise Reduction Submitted to The Engineering Honors Committee 119 Hitchcock Hall College of Engineering The Ohio State

More information

SVENSK STANDARD SS :2014

SVENSK STANDARD SS :2014 SVENSK STANDARD SS 728000-1:2014 Fastställd/Approved: 2014-06-30 Publicerad/Published: 2014-07-01 Utgåva/Edition: 1 Språk/Language: engelska/english ICS: 25.040.20 Spindlar för verktygsmaskiner Utvärdering

More information

Fourier Signal Analysis

Fourier Signal Analysis Part 1B Experimental Engineering Integrated Coursework Location: Baker Building South Wing Mechanics Lab Experiment A4 Signal Processing Fourier Signal Analysis Please bring the lab sheet from 1A experiment

More information

Modal Parameter Identification of A Continuous Beam Bridge by Using Grouped Response Measurements

Modal Parameter Identification of A Continuous Beam Bridge by Using Grouped Response Measurements Modal Parameter Identification of A Continuous Beam Bridge by Using Grouped Response Measurements Hasan CEYLAN and Gürsoy TURAN 2 Research and Teaching Assistant, Izmir Institute of Technology, Izmir,

More information

SETUP I: CORD. Continuous Systems

SETUP I: CORD. Continuous Systems Lab #8 Continuous Systems Name: Date: Section / Group: SETUP I: CORD This part of the laboratory is mainly exploratory in nature. By using your hand to force the cord close to one of its ends, you should

More information

The Scientist and Engineer's Guide to Digital Signal Processing By Steven W. Smith, Ph.D.

The Scientist and Engineer's Guide to Digital Signal Processing By Steven W. Smith, Ph.D. The Scientist and Engineer's Guide to Digital Signal Processing By Steven W. Smith, Ph.D. Home The Book by Chapters About the Book Steven W. Smith Blog Contact Book Search Download this chapter in PDF

More information

Channel Emulation Solution

Channel Emulation Solution PROPSIM MANET Channel Emulation Solution SOLUTION BRIEF Mission Critical Communications Secured Highly Scalable Channel Emulation Solution for MANET and Mesh Radio Testing. The need for robust wireless

More information

Frequency Response Function Measurements of Disc and Drum Brake With its Verification by CAE

Frequency Response Function Measurements of Disc and Drum Brake With its Verification by CAE Frequency Response Function Measurements of Disc and Drum Brake With its Verification by CAE Aniket B. Ghatwai 1, Prof. S.V. Chaitanya 2, Sandip B. Phadke 3 1 Student at AISSMS COE,PUNE,Maharashtra 2Prof.

More information

BLADE AND SHAFT CRACK DETECTION USING TORSIONAL VIBRATION MEASUREMENTS PART 1: FEASIBILITY STUDIES

BLADE AND SHAFT CRACK DETECTION USING TORSIONAL VIBRATION MEASUREMENTS PART 1: FEASIBILITY STUDIES Maynard, K. P., and Trethewey, M. W., Blade and Crack detection Using Vibration Measurements Part 1: Feasibility Studies, Noise and Vibration Worldwide, Volume 31, No. 11, December, 2000, pp. 9-15. BLADE

More information

A HARMONIC PEAK REDUCTION TECHNIQUE FOR OPERATIONAL MODAL ANALYSIS OF ROTATING MACHINERY

A HARMONIC PEAK REDUCTION TECHNIQUE FOR OPERATIONAL MODAL ANALYSIS OF ROTATING MACHINERY IOMAC'15 6 th International Operational Modal Analysis Conference 2015 May12-14 Gijón - Spain A HARMONIC PEAK REDUCTION TECHNIQUE FOR OPERATIONAL MODAL ANALYSIS OF ROTATING MACHINERY J. Bienert 1, P. Andersen

More information

STEREO IMPACT Solar Energetic Particles Package (SEP) Dynamic Test Plan

STEREO IMPACT Solar Energetic Particles Package (SEP) Dynamic Test Plan 1 2 Jet Propulsion Laboratory 352G-WBT-0507 Interoffice Memorandum January 13, 2005 To: From: Subject: References: Distribution W. B. Tsoi STEREO IMPACT Solar Energetic Particles Package (SEP) Dynamic

More information

A study of Vibration Analysis for Gearbox Casing Using Finite Element Analysis

A study of Vibration Analysis for Gearbox Casing Using Finite Element Analysis A study of Vibration Analysis for Gearbox Casing Using Finite Element Analysis M. Sofian D. Hazry K. Saifullah M. Tasyrif K.Salleh I.Ishak Autonomous System and Machine Vision Laboratory, School of Mechatronic,

More information

Fault diagnosis of massey ferguson gearbox using power spectral density

Fault diagnosis of massey ferguson gearbox using power spectral density Journal of Agricultural Technology 2009, V.5(1): 1-6 Fault diagnosis of massey ferguson gearbox using power spectral density K.Heidarbeigi *, Hojat Ahmadi, M. Omid and A. Tabatabaeefar Department of Power

More information