INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MD-44 AC MD-44 DC
|
|
- Cordelia Rose
- 5 years ago
- Views:
Transcription
1 MD-44 C MD-44 DC INSTLLTISNVISNING INSTLLTI MNUL INSTLLTIS NLEITUNG Galvanic Isolation Transient Protection alanced Transmission CE pproved Westermo Teleindustri 1999 REV. Omvandlare RS-22 RS-422/485 Converter RS-22 RS-422/485 RS-22 RS-422/485 Wandler
2 Specifications MD-44 Transmission Interface 1 synchronous, full/half duplex or simplex EI RS-22-C/CCITT V.24/V.28 9-position D-sub female, DCE Interface 2 EI RS-422/RS-485/CCITT V.11 Data rate 00 bit/s 8.4 kbit/s Indicators Power, RD, DCD, CTS, RTS, TD Insulation Galvanic insulation with opto-coupler (data transmission) and transformer (supply) Insulation voltage 150 Overvoltage protection Mains: reakdown voltage 4 at 2 C Interface 2: reakdown voltage transmitter and receiver 7V Surge capacity 0.6 kw for 1ms Power supply 2 +15/ 10% 48 62Hz Fuse 100 m fast 5x20 mm Power consumption Max 22 m at 2 Temperature range 5 50 C, ambient temperature Humidity 0 95% RH, non-condensing Dimensions 55x100x128 mm (WxHxD) Weight 0.5 kg C / 0.25 kg DC Mounting On DIN-rail 5 mm Switch settings MD-44 The MD-44 can through different switch settings be adapted to a variety of running conditions. To set the switches, open the plastic case with e.g. a screw-driver. Danger! Do not open connected unit PWR TD RD RTS CTS DCD DTR DSR SG MD-44 DC V24/RS-22-C RS-422/RS-485/V11 CVERTER V24/RS-22-C CNECTI :1-4 :1-9 LINE CNECTI R+ R- T+ T POWER
3 Selection of data rate Selection of bits /4-wire transmission wire wire Termination with fail-safe * : 8-9 not used. Terminated (4-wire) 124 * The fail-safe function forces the signal state of the receiver to OFF when the connected transmitter is in tri-state (transmitter inactive). The receiver located furthest away shall be terminated Terminated (2-wire) No termination Supervision table when selecting data bits 7 bits 8 bits No parity Parity 1 stop bit 2 stop bits Number of bits Factory settings 124 : 8 and 9 not used
4 Connections MD-44 C Line connection (5-position screw-terminal) Direction No. CCITT V.11 Description Receiver 1 (R+) Receiver 2 (R ) Transmitter (T+) Transmitter 4 (T ) 5 Shield The definations R+/R,T+/T can be various between different manufactures. Terminal connection (DCE) (RS-22-C/V.24/V.28, 9-position D-sub, female) Direction 1) Pin Screw- CCITT V.24 Description no. terminal Circuit number I 8 10 TD / Transmitted Data O RD / Received Data I RTS / Request to Send O CTS / Clear to Send O DSR / Data Set Ready 5 9 & 1 102SG / Signal Ground O DCD / Data Carrier Detect I 4 108/2DTR / Data Terminal Ready 1) I = input O = output on MD-44 Line connection 4-wire 2-wire MD-44 Twisted pairs RS-422/485 equipment MD-44 Receiver 1 2 Transmitter Transmitter Receiver Transmitter/ 4 Receiver 4 Shield 1) 5 Shield 1) 5 / / Twisted pairs / / RS-422/485 equipment Transmitter/ Receiver 1) If shielded cable is used, connect the shield only at one end to avoid ground currents
5 Transmission range (interface 2) Use twisted pair cable. Max transmission range 1200 m (cable specifications 0. mm 2 and capacitance 42pF/m). The transmission range will increase if a cable with lower capacitance and larger diameter is used. Use shielded cable in heavy industrial environments. MD-44 DC Specifications Power supply 12 6V DC Power consumption Max 1.8W Insulation 100 Fuse F1 1.6 fast 5x20 mm I övrigt gäller MD-44 C specifikationerna Connections ccording to MD-44 C, except power supply Connection no. Power supply 1 Voltage 2+ Voltage Switch settings ccording to MD-44 C
6 Hints RS-422/485 was designed for multidrop applications. When a system is installed it should form a bus structure (see diagrams). Star shaped networks should never be created, there are other Westermo products designed to work in star net applications. To get a correct installation according to the RS-422/485 specification it s very important that the line is terminated at the correct points. The recommendation is to terminate the receiver on the master unit and the final bus slave unit. See diagrams for details of how this is done with RS-485 (2-wire) and RS-422 (4-wire). The line transmitter used in the MD-44 is activated by data received on the RS-22 interface, unlike conventional converters that rely on a control signal (e.g. RTS). If any problems do occur on set up of the MD-44, the LED s will be helpful. PWR: The unit has power. RD: Data received on the RS-422/485 interface. DCD: Follows RD in two wire operation. lways active for four wire. CTS: Follows RTS. RTS: Status of RTS from the RS-22 interface. TD: Data received on RS-22 interface. =Termination Max metres Max 0. metre Max 2 connections =Termination Max 2 connections N.. R+/R, T+/T definitations are not standard, it can help to shift and if the unit does not work
7 OWN COMMENTS
8 V.24/RS-22 lock diagram V.11/RS-422 RS-485 X TD TD X2 RTS CTS 7 8 DCD RTS CTS +5V us termination 4 4 DCD 1 DSR 6 +5V RD ctivity Trig +5V us termination 2 RD SG 2 5 J2 1) 6, 7 +12V +5V -12V & 1 X ' ' Shield PE Power supply F1 Insulated power supply PE J 1) +5V 1) The jumpers J2 and J is normally not mounted Westermo Teleindustri have distributors in several countries, contact us for further information. Westermo Teleindustri S Stora Sundby, Sweden Phone Fax info@westermo.se Westermo Web site: Westermo Data Communications Ltd Unit 14 Talisman usiness Centre Duncan Road Park Gate, Southampton SO1 7G Phone: +44(0) Fax.:+44(0) sales@westermo.co.uk Web: Subsidiaries Westermo Data Communications GmbH ruchsaler Straße 18, 6875 Waghäusel Tel.: +49(0) Fax.:+49(0) westermo.germany@t-online.de TunaTryck, Eskilstuna, Sweden
INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MD-42 AC MD-42 DC
MD- AC MD- DC INSTALLATISANVISNING INSTALLATI MANUAL INSTALLATIS ANLEITUNG Galvanic Isolation 65-00 Transient Protection Balanced Transmission CE Approved Westermo Teleindustri AB 999 Rev. B Omvandlare
More informationArtisan Technology Group is your source for quality new and certified-used/pre-owned equipment
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED
More informationINSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MA-12 AC MA-12 DC. Korthållsmodem Short haul modem Kurzstreckenmodem
MA- AC MA- DC INSTALLATISANVISNING INSTALLATI MANUAL INSTALLATIS ANLEITUNG Galavanic Isolation Transient Protection 0-00 Balanced Transmission CE Approved Westermo Teleindustri AB REV. A Korthållsmodem
More informationINSTALLATIONSANVISNING MD-21 AC INSTALLATION MANUAL REV. A MD-21DC INSTALLATIONS ANLEITUNG
MD- AC MD-DC INSTALLATISANVISNING INSTALLATI MANUAL INSTALLATIS ANLEITUNG Galavanic Isolation -00 Transient Protection CE Approved Westermo Teleindustri AB REV. A Strömslingeomvandlare Current loop converter
More informationINSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MA-19. Korthållsmodem Short Haul Modem Kurzstreckenmodem
INSTALLATISANVISNING INSTALLATI MANUAL INSTALLATIS ANLEITUNG Galvanic Isolation 0-00 Transient Protection Balanced Transmission CE Approved Westermo Teleindustri AB REV. A Korthållsmodem Short Haul Modem
More informationINSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG LD-34 AC LD-34 DC
LD-34 AC LD-34 DC INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG Galvanic Isolation 6603-2001 CE Approved Westermo Teleindustri AB 1999 REV. A 4 kanalig switch - /V.24 4 channel switch
More informationINSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MANUEL D INSTALLATION MD-45 AC MD-45 LV/HV
MD-45 AC MD-45 LV/HV INSTALLATISANVISNING INSTALLATI MANUAL INSTALLATIS ANLEITUNG MANUEL D INSTALLATI 6157-2003 Westermo Teleindustri A 2003 REV.A Galvanic Isolation Transient Protection alanced Transmission
More informationMD-45 AC MD-45 LV/HV INSTALLATION MANUAL
MD-45 AC MD-45 LV/HV INSTALLATI MANUAL 6157-2213 Westermo Teleindustri A 2003 REV.A Galvanic Isolation Transient Protection alanced Transmission CE Approved Converter RS-232 RS-422/485 www.westermo.us
More informationINSTALLATIONSANVISNING INSTALLATION MANUAL MA-44/MA-44DC OMVANDLARE RS RS-422/485 CONVERTER RS RS-422/485. Balanced Transmission
NSTALLATNSANVSNNG NSTALLATN MANUAL MA-/MA-DC MVANDLARE RS- -- RS-/8 CNVERTER RS- -- RS-/8 Galvanic nsulation Transient Protection alanced Transmission CE Approved SPECFKATNER SPECFCATNS ANSLUTNNGAR CNNECTNS
More informationUser Guide. Westermo Teleindustri AB 2004 REV.A MDW Converter RS-232 RS-422/485.
User Guide MDW-45 6617-2201 Westermo Teleindustri AB 2004 REV.A Converter RS-422/485 www.westermo.com Safety! Before using this unit: Read this manual completely and gather all information on the unit.
More informationMDW-45 Converter RS RS-422/485
www.westermo.com MDW-45 Converter RS-232 - RS-422/485 2 6617-2203 General information Legal information The contents of this document are provided as is. Except as required by applicable law, no warranties
More informationUniversal RS232/CMOS to RS422/RS485 Converter
TOSHIBA INTERNATIONAL CORPORATION Universal RS232/CMOS to RS422/RS485 Converter Rev No.: 2 Page No.: 1 RS232/CMOS to RS422/RS485 Converter converts RS232/CMOS lines to balanced RS422 or RS485 signals.
More informationADA User manual ADA RS-232 to RS-485 / RS-422 Converter
User manual RS- to RS- / RS- Converter Copyright 001-01 CEL-MAR sp.j. 1 io_ada-100_v._en Contents 1. GENERAL INFORMATION... 1.1. WARRANTED INFORMATION... 1.. GENERAL CONDITIONS FOR SAFE USE... 1.. CE LABEL...
More informationADA-1028L. User manual ADA-1028L. RS232 to Current Loop 2-wire CLO Converter. 1 io_ada-1028l_v.1.10_en. Copyright CEL-MAR sp.j.
User manual ADA-1028L to Current Loop 2-wire Converter Copyright 2001-2017 CEL-MAR sp.j. 1 io_ada-1028l_v.1.10_en Contents 1. GENERAL INFORMATION... 3 1.1. WARRANTED INFORMATION... 3 1.2. GENERAL CONDITIONS
More informationModem 1200 baud 500FSD10 EDS500 series - FSK modems
Manual Modem 1200 baud 500FSD10 EDS500 series - FSK modems Application, characteristics and technical data have to be taken from the hardware data sheet: 500FSD10 Data sheet 1KGT150982 Operation The 500FSD10
More informationFOM-5A, 6A Asynchronous Fiber Optic Modems
ORDERING FOM-5A/*/+ Asynchronous Sub-miniature Fiber Optic Modem FOM-6A/*/+/# Asynchronous Miniature Fiber Optic Modem * Specify: F for female 25-pin connector M for male 25-pin connector + Specify: ST
More informationUser Guide Westermo Teleindustri AB TR-36. Tele and leased line modem for RV rack system.
User Guide 6614-2202 TR-36 Westermo Teleindustri AB 4 3 2 1 4 3 2 1 Tele and leased line modem for RV-07 19 rack system www.westermo.com Legal information The contents of this document are provided as
More informationMiniature Synchronous Multipoint Modems
ME1735A-F JULY 2003 Miniature Synchronous Multipoint Modems CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support 24 hours
More informationMULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE
Distribué par : Contact : hvssystem@hvssystem.com Tél : 0326824929 Fax : 0326851908 Siège social : 2 rue René Laennec 51500 Taissy France www.hvssystem.com MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE
More informationUniversal Converter Covers All the Bases- RS-232 to 4-wire RS-422, 2-wire or 4-wire RS-485
4WSD9R0712-1/4 Model 4WSD9R Universal Converter Covers All the Bases- RS-232 to 4-wire RS-422, 2-wire or 4-wire RS-485 The 4WSD9R Universal Converter is a port-powered or externally powered two-channel
More informationM-Bus Master MultiPort 250L Installation and User Guide
Installation and User Guide Kamstrup A/S Industrivej 28, Stilling DK-8660 Skanderborg T: +45 89 93 10 00 info@kamstrup.com kamstrup.com Contents 1 Introduction 3 1.1 Design 3 2 Functionality 4 2.1 Overview
More informationA50/A51/A60. June 2008 (4th Edition) All Rights Reserved
A50/A51/A60 June 2008 (4th Edition) All Rights Reserved Part I - A50/A51 RS-232 to RS-422/RS-485 Converter A50/A51 RS-232 to RS-422/RS-485 Bidirectional Converter Part II - A60 RS-232 Surge Protection
More informationSelection guide. Communication accessories. Communication accessory selection guide. Characteristics
Communication accessories Selection guide There are 2 types of Sepam communication accessories: b communication interfaces, which are essential for connecting Sepam to the communication network b converters
More informationModem 9600 baud 500FSD11 EDS500 series - FSK modems
Data sheet Modem 9600 baud 500FSD11 EDS500 series - FSK modems Voice frequency telegraphy device (VFT) Transparent up to 9600 baud Can be connected to 23WT24 DIN rail mounted 24...60 V DC supply voltage
More informationConcept of Serial Communication
Concept of Serial Communication Agenda Serial v.s. Parallel Simplex, Half Duplex, Full Duplex Communication RS-485 Advantage over RS-232 Serial v.s. Parallel Application: How to Measure the temperature
More informationVoice-Frequency Telegraph Modem HY101-SWT
Voice-Frequency Telegraph Modem HY101-SWT Revision: August 2014 V 1.6 08/14 1 HYTEC Gerätebau GmbH 2007 / HYTEC Gerätebau GmbH All rights reserved No part of this document may be reproduced or used except
More informationZCS485 User s Manual. Version ZYPEX, Inc.
ZCS485 User s Manual Version 2.2 2004 ZYPEX, Inc. Table of Contents Product Description 1 ZCS485 Configuration & Setup 2 4-wire Operation 2 2-wire Operation 2 Dual Port Operation 2 Carrier Detect 2 Transmitter
More informationLecture #3 RS232 & 485 protocols
SPRING 2015 Integrated Technical Education Cluster At AlAmeeria E-626-A Data Communication and Industrial Networks (DC-IN) Lecture #3 RS232 & 485 protocols Instructor: Dr. Ahmad El-Banna 1 Agenda What
More informationInterface: Serial EIA RS-232D/CCITT V.24, DCE; RTS/CTS delay 0,8 or 64 ms (user-selectable).
BLACK BOX PWR RTS TD-1 RD-1 TD-2 DCD RD-2 TEST DIG ANA REM LDM-MR 19.2 REM ANA DIG AGC 2/4 WIRE ABLE / ABLE SWITCHES 2 W 4 W 1 2 3 4 CARRIER LEVEL 0 dbm -3 dbm -6 dbm -9 dbm PIN 21 (RLB) RPF PIN 18 AN.
More informationRS-232 / 20mA Interface Converter ELO E00Q. Operation manual
RS-232 / 20mA Interface Converter ELO E00Q Operation manual 2 ELOE00QZKE001 1.0 Introduction 4 1.1 Use of the converter 4 2.0 Operation principles 4 3.0 Installation 4 3.1 Converter connection to RS-232
More informationMODEL: DLS. Telemetering System
POW RUN SA SA RT RU MODEL: DLS Telemetering System TELEMETERING UNIT Functions & Features Interfacing remote I/O devices with a modem for a telemetering system Process I/O (.0) [] POWER INPUT AC Power
More informationUSER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)
USER MANUAL MODEL 2017A RS-232 to 20ma Current Loop Converter Part# 07M2017A-A Doc# 073021UA Revised 10/15/93 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com 1.0 WARRANTY
More informationFOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology
FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V
More information1 What s in the shipping package?
SST 900B 900 MHz RS 232/RS 485 Wireless Modem Quick Start Guide 1 What s in the shipping package? SST-900B Wireless Modem CA-0910 Quick Start CD 3dBi 900M Hz Antenna Guide 2 External switch introduction
More informationPRODUCT INFORMATION B&B ELECTRONICS. Port-Powered RS-232 Fiber Optic Modem with Handshake Support. Model 9PFLST. Description. RS-232 Connections
-01-1/ 00 by B&B Electronics. All rights reserved. Model Port-Powered RS- Fiber Optic Modem with Handshake Support Description The allows any two pieces of RS- asynchronous serial equipment to communicate
More informationM9606. FSK Modem. 5C Communications Inc.
FSK Modem Application modem is a voice-frequency telegraphy unit (VFT unit) which operates according to the principle of binary frequency shift keying. It is designed especially for Power Industrial applications.
More informationInterface converter G kbit/sec
converter User s Guide 12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901 Interface converter G.703.1 64 kbit/sec Features Maximum line attenuation
More informationIntermittent Vibration 0.075
FEATURES DESCRIPTION PLC-COM-CM1 Series Multi Drop Configuration of up to 32 Units Baud Rates Range from 300 to 38,400 bps 1:1/1:N/N:M (RS-422) Communication is Supported Full-Duplex (RS-422) and Half-Duplex
More informationTelemetrie-Messtechnik Schnorrenberg
Telemetrie-Messtechnik Schnorrenberg CT16-Wheel User manual TMS Telemetrie-Messtechnik Schnorrenberg Dipl.-Ing. Werner Schnorrenberg Habichtweg 30, D-51429 Bergisch Gladbach, Tel: 02204-9815-52, Fax: 02204-9815-53,
More informationMULTICONT MULTICHANNEL PROCESS CONTROLLER
MULTICONT MULTICHANNEL PROCESS CONTROLLER O U R P R O F E S S I O N I S Y O U R L E V E L S Y S T E M S APPLICATION The MULTICONT is a universal interface between Nivelco's HART-capable intelligent level
More informationPower Quality and Energy Measurement PEM735
Power Quality and Energy Measurement PEM75 PEM75_D00084_01_D_XXEN/01.2015 Power Quality and Energy Measurement PEM75 class A Product description The digital universal measuring device PEM75 is suited for
More informationMoxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter
Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter Hardware Installation Guide First Edition, August 2013 2013 Moxa Inc. All rights reserved. P/N: 1802012800011 Introduction The ICF-1280I series
More informationModem RS232/RS422/RS485. to MM optic fibers. RS-232 to Multimode Optic. Fiber Converter. Characteristics DIN rail mounting.
RS-232 to Multimode Optic Modem RS232/RS422/RS485 Fiber Converter to MM optic fibers ELO E14C E17A DIN rail mounting TxD, RxD up to transferring 6km over MM fiber Communication Max. data rate 115.2 protocol
More informationQuidoDuplex RS. Set for bi-directional transmission of 4 or 8 two-state signals over RS485 or RS June 2011 w w w. p a p o u c h.
Set for bi-directional transmission of 4 or 8 two-state signals over RS485 or RS232 7. June 2011 w w w. p a p o u c h. c o m Q uidoduplex RS Datasheet Created: 3/16/2006 Last update: 6/7/2011 8:57 AM Number
More informationAbsolute encoder HE-65
TR - ECE - TI - GB - 00041-01 04/08/2016 SLIN-BUS Absolute encoder HE-65 Technical Information TR-Electronic GmbH D-78647 Trossingen Eglishalde 6 Tel.: (0049) 07425/228-0 Fax: (0049) 07425/228-33 email:
More informationTD-36 TD-36. DIN-rail Tele and Leased Line modem TD DIN-rail Tele and Leased Line modem with I/O and RS-485. User Guide
User Guide 6618-2202 TD-36 Westermo Teleindustri AB TD-36 DIN-rail Tele and Leased Line modem TD-36 485 DIN-rail Tele and Leased Line modem with I/O and RS-485 www.westermo.com Legal information The contents
More informationModel FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter
Model FLSC-C3-XX DC Powered Microprocessor Controlled Transmitter CONTENTS. Introduction----------------------------------------------------------------- 2 2. Specifications ---------------------------------------------------------------
More informationInstallation and Operation Manual HS-R. 4-Channel Low Speed Data Module with V.110 Rate Adaptation MEGAPLEX-2100 MODULE
Installation and Operation Manual HS-R 4-Channel Low Speed Data Module with V110 Rate Adaptation MEGAPLEX-2100 MODULE MEGAPLEX-2100 MODULE HS-R 4-Channel Low Speed Data Module with V110 Rate Adaptation
More informationTVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active
Technical manual BA 0318 Signal converter Isolation amplifier active for galvanic isolation, conversion and adjustment of electrical standard signals Evaluable input signals Direct voltage 0...10V / 0...1V
More informationMGE TM Galaxy TM , 60 Hz kva
Home Alarms Online Trend Statistics Rectifier Battery Inverter Bypass AC Bypass Output Set up Normal AC Q4S Load protected QBP QF 0 Hour 50 Min. 5 kva 00% 0% 00% 0 50% Load equipment 0 80% 50% Remote vision
More informationRS232 to RS485 or RS422 line converter with isolation. >>> Distribucion: ER-Soft, S.A. Tel: <<<
RS232 RS485/422 RS232 to RS485 or RS422 line converter with isolation >>> Distribucion: ER-Soft, S.A. www.er-soft.com info@er-soft.com Tel: +34 916-408-408
More informationXIOC technology and networking modules
/ XIO XIO digitale and analog input/output modules XIO technology and networking modules XIO the compact I/O and much more XIO are local expansion modules for direct connection to all Xontrol controllers.
More informationCP485-4 User s Manual
CP485x4 User s Manual Version 1.0 2005 ZYPEX, Inc. CP485-4 User s Manual Table of Contents Table of Contents Product Description 1 CP485x4 Configuration & Setup 2 Power 2 Baud Rate 2 Control Mode 2 Duplex
More informationUSER'S MANUAL. Model : K
USER'S MANUAL Model : 2000-64K TM GINA MODEL 2000-64K Overview GINA Model 2000-64K is a stand-alone, high frequency data transceiver using spread spectrum technology. GINA 2000-64K capabilities include
More informationNon-Powered Interface Converters RS-232 to RS-530 RS-422 to V.35 RS-232 to RS-485 RS-232 to RS-422/RS-449
IC237A IC482A JUNE 1995 IC486A IC487A-F Non-Powered Interface Converters S-232 to S-530 S-422 to V.35 S-232 to S-485 S-232 to S-422/S-449 CUSTOME SUPPOT INFOMATION Order toll-free in the U.S. 24 hours,
More informationINDUSTRIAL OPTO-ISOLATED RS-232 REPEATER
QUICK START GUIDE ICD201A INDUSTRIAL OPTO-ISOLATED RS-232 REPEATER 24/7 TECHNICAL SUPPORT AT 877.877.2269 OR VISIT BLACKBOX.COM STEP 1 - What s Included ICD201A Industrial Opto-Isolated RS-232 to RS-422/485
More informationUser Guide. Westermo Teleindustri AB 2006 IDW ISDN Terminaladapter.
User Guide IDW-90 Westermo Teleindustri AB 2006 6620-2200 ISDN Terminaladapter www.westermo.com Legal information The contents of this document are provided as is. Except as required by applicable law,
More informationUSER MANUAL MODEL Parallel to Serial/ Serial to Parallel Interface Converter
USER MANUAL MODEL 2029 Parallel to Serial/ Serial to Parallel Interface Converter C E R T I F I E D An ISO-9001 Certified Company Part #07M2029-B, Rev. C Doc. #102011UB Revised 6/16/09 SALES OFFICE (301)
More informationElectronics / Water analogy. Resistor. Inductance. Capacitor. Water Electronics Energy - Energy Pressure - Voltage Flow - Current Volume - Charge
Electronics / Water analogy Water Electronics Energy - Energy Pressure - Voltage Flow - Current Volume - Charge Resistor U = R * I 1 Capacitor U 1 i dt C U L di dt Inductance Turbine Flywheel Diode Transistor
More informationDATA SHEET. OD Precision. Displacement sensors for precise and comprehensive measurement tasks
DATA SHEET OD Precision Displacement sensors for precise and comprehensive measurement tasks OD Precision Displacement sensors for precise and comprehensive measurement tasks Displacement sensors from
More informationCable and Port Specifications
APPENDIX D This appendix includes the following information: Cables and Adapters Provided, page D-1 Console Port, page D-2 COM1 Port, page D-3 MGMT 10/100 Ethernet Port, page D-5 SFP Transceiver Specifications,
More informationSelect datum Page backward in. parameter list
HEIDENHAIN Working with the measured value display unit ND Actual value and input display (7-segment LED, 9 decades and sign) Select datum Page backward in parameter list Confirm entry value Set display
More informationMULTICONT OUR PROFESSION YOUR LEVEL
MULTICONT M U LT I C H A N N E L P R O C E S S C O N T R O L L E R OUR PROFESSION IS YOUR LEVEL APPLICATION The MULTICONT is a universal interface between Nivelco's HART-capable intelligent level transmitters
More informationSerial Input/Output. Lecturer: Sri Parameswaran Notes by: Annie Guo
Serial Input/Output Lecturer: Sri Parameswaran Notes by: Annie Guo 1 Serial communication Concepts Standards USART in AVR Lecture overview 2 Why Serial I/O? Problems with Parallel I/O: Needs a wire for
More informationMV110-8AS. Analog input module 8 channel. User guide
MV110-8AS Analog input module 8 channel User guide MV110-8AS_2016.12_0226_EN All rights reserved Subject to technical changes and misprints Contents 1 Description... 2 1.1 Function... 2 1.2 RS485 network...
More informationDUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER
OPERATOR S MANUAL DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER Masibus Automation & Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar-382044, Gujarat, India Web Site: www..com
More informationCONTROL MICROSYSTEMS SCADAWave Radio Transceiver. Hardware Manual
5908 SCADAWave Radio Transceiver Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9 Technical
More informationOD Max and OD Max Transparent displacement sensors highly accurate, non-surface dependent distance measurement
OD Max and OD Max Transparent displacement sensors highly accurate, non-surface dependent distance AUDIN - 8, avenue de la malle - 70 Saint Brice Courcelles - Tel : 0..0.0. - Fax : 0..0.8.0 - Web : http:
More informationSelect datum Page backward in parameter list
HEIDENHAIN Working with the measured value display unit ND Actual value and input display (7-segment LED, 9 decades and sign) Select datum Page backward in parameter list Confirm entry value Set display
More informationUser Guide Westermo Teleindustri AB IDW-90. ISDN Terminaladapter.
User Guide 6620-2200 IDW-90 Westermo Teleindustri AB ISDN Terminaladapter www.westermo.com Legal information The contents of this document are provided as is. Except as required by applicable law, no warranties
More informationThis FAQ covers Single Direction use of current loop with transmitting devices.
PAGE 1 OF 5 This FAQ covers Single Direction use of current loop with transmitting devices. Q: How do I connect the Current Loop Converter to my Current Loop device? A: This Current Loop interface has
More information2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS
Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Tel.: 0640 807-0 Fax: 0640 807-259 IT system floor-standing distribution cabinet Series -IPS-F/EDS for supplying power to medical locations
More informationZ-10-D-IN. RS485 Modbus Module 10 Digital Inputs
S SENECA Z-PC Line EN Installation Manual Contents: - General specifications - Technical specifications - Installation rules - Electrical connections - Modbus connection rules - DIP-switches settings -
More informationDigiPoints Volume 1. Student Workbook. Module 2 Modem Overview
Modem Overview Page 2.1 DigiPoints Volume 1 Module 2 Modem Overview Summary One of the potential advantages the cable telecommunications industry has is the ability to carry data signals at speeds significantly
More informationEPAD2/CPAD2/CPAD3 Modules. Modules with CAN or RS-485 Interface
EPAD & CPAD Modules Automotive Energy & Power Analysis Aerospace & Defense Transportation General Test & Measurement EPAD2/CPAD2/CPAD3 Modules Modules with CAN or RS-485 The EPAD2 and CPAD2/CPAD3 series
More informationFA Wireless SS Terminals
FA Wireless SS Terminals WT30 Construct a Wireless System for ON/OFF Data Collection That Is Ideal for Monitoring Production Site Equipment Wireless Slave Station equipped with I/O. Height of 90 mm and
More informationConfirm entry value Set display to value from Actual value and input display Select datum P79 (P80!) (7-segment LED,
HEIDENHAIN Working with the measured value display unit ND 261 Confirm entry value Set display to value from Actual value and input display Select datum P79 (P80!) (7-segment LED, Page backward in 9 decades
More information285E Series DIGITAL FIBER OPTIC AUDIO/DATA TRANSPORT SYSTEM
285E Series DIGITAL FIBER OPTIC AUDIO/DATA TRANSPORT SYSTEM BCI reserves the right to make changes to the products described herein without prior notice or consent. No liability is assumed as a result
More informationPower Quality and Energy Measurement PEM575
Power Quality and Energy Measurement _D00016_00_D_XXEN/06.2013 Power Quality and Energy Measurement Product description The digital universal measuring device is suited for measuring and displaying electrical
More information9600 bps, Dual Modem 170 Card Private Wire Only
896 9600 bps, Dual Modem 170 Card Private Wire Only Users Guide 280 Interstate 80 West Exit 1 / PO Box 1330, Verdi, NV 89439 Phone: 775-345-8000 Fax: 775-345-8010 E-mail: traffic@sgdi.net TABLE OF CONTENTS
More informationThis FAQ covers the common questions from technicians installing these converters.
PAGE 1 OF 6 This FAQ covers the common questions from technicians installing these converters. Q: How do I connect the Current Loop Converter to my Current Loop device? A: This Current Loop interface has
More informationInterface converter RS-232 / RS-485 TECHNICAL GUIDE. Review date: 9 Jun 2010 TECHNOTRADE LTD
Interface converter RS-232 / TECHNICAL GUIDE Review date: 9 Jun 2010 TECHNOTRADE LTD This document is the property of TECHNOTRADE LTD It is not to be used or duplicated without written permission of the
More informationProduct Information. EQN 1337 F Absolute Rotary Encoder with Tapered Shaft for Fanuc Controls with i Interface
Product Information EQN 1337 F Absolute Rotary Encoder with Tapered Shaft for Fanuc Controls with i Interface 11/2017 EQN 1337 F Rotary encoders for absolute position values Installation diameter 65 mm
More informationCTP16-Rotate. KMT - Kraus Messtechnik GmbH
KMT - Kraus Messtechnik GmbH Gewerbering 9, D-83624 Otterfing, Germany, 08024-48737, Fax. 08024-5532 Home Page http://www.kmt-telemetry.com, Email: info@kmt-telemetry.com CTP16-Rotate 16 channel telemetry
More informationMODEL AT-10 ANALOG TRANSMITTER
MODEL AT-10 ANALOG TRANSMITTER INSTALLATION & OPERATING MANUAL Industrial Weighing Systems 9 Richmond Street Picton, Ontario K0K 2T0 Phone: 613-921-0397 Fax: 613-476-5293 Web: www.iwsystems.ca info@iwsystems.ca
More informationABSOLUTE ROTARY ENCODER SSI
Main Features - Compact and heavy-duty industrial model - Interface: Synchronous-serial (RS422/485) - Housing: 58 mm - Shaft: 6 or 10 mm - Resolution: Max. 25 Bit =,554,42 steps over 4,096 revolutions
More informationPower Quality and Energy Measurement PEM575
Power Quality and Energy Measurement _D00016_03_D_XXEN/12.2015 Power Quality and Energy Measurement Product description The digital universal measuring device is suited for measuring and displaying electrical
More informationADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W
ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000
More informationComponents Signal Conditioning For Your Computer Instruments Standard Models
EPAD2/CPAD2 Modules Automotive Energy & Power Analysis Aerospace & Defense Transportation General Test & Measurement CAN and RS-485 Modules EPAD2/CPAD2 Modules The EPAD2 and CPAD2 series are multichannel
More informationEnergy Management Energy Meter Type EM21 72R Retro-Fit
Energy Management Energy Meter Type EM21 72R Retro-Fit Including 3 miniature split-core current sensors 10mm (90A), 16mm (150A) and 24mm (250A) diameter holes Class A (kwh) according to EN50470-3 Class
More informationSIN 57 Issue 2.4 May 2018
SIN 57 Issue 2.4 May 2018 Suppliers' Information Note For The BT Network BT KiloStream X.21 Interface Service Description Each SIN is the copyright of British Telecommunications plc. Reproduction of the
More informationRM868500D. Introduction. Features. 868MHz 500mW RS232 / RS485 / RS422 Radio Modem. Operating Manual English 1.01
RM868500D 868MHz 500mW RS232 / RS485 / RS422 Radio Modem Operating Manual English 1.01 Introduction The RM868500D radio modem acts as a wireless serial cable replacement and can wirelessly connect various
More informationDSP4xxFP SA USER S MANUAL. A01561 Rev. A. This Manual covers all configurations of the DSP4xxSA Modem with the Serial Number SA and up.
DSP4xxFP SA USER S MANUAL A01561 Rev. A This Manual covers all configurations of the DSP4xxSA Modem with the Serial Number SA700425 and up. DSP4xxSA User s Manual A01561 Rev. X Proprietary Data This document
More informationLiquid Level Sensors. M-Series Magnetostrictive Sensors
Liquid Level Sensors M-Series Magnetostrictive Sensors Model USTD II Underground Storage Tank Level Sensor For Leak Detection and Inventory Monitoring 550980 C Installation Instructions Table of Contents:
More informationEPAD2/CPAD2/CPAD3 Modules. Modules with CAN or RS-485 Interface
EPAD & CPAD Modules EPAD2/CPAD2/CPAD3 Modules Modules with CAN or RS-485 The EPAD2 and CPAD2/CPAD3 series are multichannel modules and combine analog signal conditioning and A/D converter in an extremely
More informationLCM100 USER GUIDE. Line Carrier Modem INDUSTRIAL DATA COMMUNICATIONS
USER GUIDE INDUSTRIAL DATA COMMUNICATIONS LCM100 Line Carrier Modem It is essential that all instructions contained in the User Guide are followed precisely to ensure proper operation of equipment. Product
More informationIndustrial PSU with universal input voltage range ( VAC line to line) and configurable output voltage. North America
World-Wide 3-phase Input Voltage Range (nom. 200 Vrms to 480 Vrms), PF > 0.94 High Power Density 16 W/in 3 94% Typical Efficiency Parallel Operation up to 16 Units (50.4 kw) Cold-Plate Cooling System -25
More informationKiloStream Data Sheet
KiloStream Data Sheet KiloStream speeds The choice of interfaces and speeds shown below enable a wide variety of equipment conforming to CCITT* standards to be connected. Speeds and interfaces Speed kbit/s
More informationPEM353. Universal measuring device
353 Universal measuring device 353_D00335_00_D_XXEN/06.2018 353 Universal measuring device Product description The digital universal measuring device 353 is used to record and display measured quantities
More informationThe i-7531 CAN Repeater
The i-7531 CAN Repeater User s Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date of delivery to the original purchaser.
More information