Modem RS232/RS422/RS485. to MM optic fibers. RS-232 to Multimode Optic. Fiber Converter. Characteristics DIN rail mounting.

Size: px
Start display at page:

Download "Modem RS232/RS422/RS485. to MM optic fibers. RS-232 to Multimode Optic. Fiber Converter. Characteristics DIN rail mounting."

Transcription

1 RS-232 to Multimode Optic Modem RS232/RS422/RS485 Fiber Converter to MM optic fibers ELO E14C E17A DIN rail mounting TxD, RxD up to transferring 6km over MM fiber Communication Max. data rate protocol kbps independent Point-to-point voltage or 9-24 ring V topology DC User Max. selectable range 2 km metallic interface Desktop or DIN rail versions 9-24 V DC RS-232 is the interface with asymmetric signals. The Modem maximum converts load capacitance the data signals can be of 2500 the pf. duplex It corresponds interfaces RS232, to the 50m RS422 of the and typical RS422-multidrop twisted pair cable. as well as a halfduplex The load interface impedance RS485 can to be multimode 3-7 kiloohm optic and fibers it enables with ST to optic induce connectors. the disturbing It is impulses designed even to point to-point from the soft supplies or ring topology. into the cable. Use The asymmetric of the converter signals can not eliminate the influence of the Conversion signal ground s of metallic potential media drifts. to fiber optic is suitable especially: Therefore the RS-232 interface is destined for the point-topoint 1) in connection the high interference at 15 m distance. level area, The terminal devices (DTE) 2) if must the higher have the isolation same signal is required, grounds (switching potential. Fiber 3) if Optic the metallic Modem line can Application not be used because of The 4) fiber if the optic higher cable transport is resistant security against and the safety electrical is disturbances and against the influences of the atmospheric electricity. 5) if isolation It gives via the the maximum optocouplers protection is not suitable of the DTE for and the high different reliability reasons, of communication. The security of communication 6) to increase over a range. optic cable is last but not least advantage. A pair of modems communicates each other over a duplex multimode Principles optic of Operation fiber. The wave length of the signal is 1300 ELO nm. E14C Optic converts signal TxD has been signal pulsewidth to transmitting modulated optic (PWM). cable and the signal from the receiving cable converts to RxD. This way the full duplex connection can be realized. There are not any other signals transmitted over optic fiber. ELO E14C has two switches: Communication data ranges for RS232 are kbps, Switch IDLE sets a polarity of optic signal. In LIGHT for RS485/422 from 0 to 2 Mb/s. There are two data position the light in transmitting fiber corresponds to idle indicators Tx and Rx. state of TxD and the light coming from receiving fiber is Modem doesn t need any setting of data rate or data format been interpreted as idle state of RxD. In DARK position parameters if the RS232 interface was set. In the other cases of IDLE the dark is the idle state in the fibers. it is necessary to use terminators, pull-up and pull-down In LIGHT mode DTE is getting the information about resistors according to the metallic line length, data rate or a optic cable s integrity all the time. So this mode is suitable number of RS485 users. for using in security systems. All the interfaces are connected to a terminal block and can Switch ECHO in ECHO=OFF position is suitable for be chosen and activated by the switches. two-point full duplex lines. In ECHO=ON position data Terminators, pull-up and pull-down resistors are integrated from receiving optic fiber are copied not only to RxD, but in modem and they can be used by the switches too. to transmitting fiber too. This way data can be delivered to Data from optic receiver can be copied (echoed) to the all users of ring optic net. This configuration is equivalent transmitter if the ECHO switch was activated. This to bus structure on metallic lines. There must be function is important especially in ring topology. a communication protocol which must synchronize the Power supply of DC 9 24 V nominal or 7 30 V (limits) stream of data packets among wars of the net. has its own clamps. Electrical Interface RS RS232 TxD, RxD TxD and RxD - RS422 Tx+,Tx-, Rx+,Rx- Control signals local loops RTS-CTS - RS485 TxRx+, TxRx- DTR-DSR-DCD Type of metallic int. connector terminal block 3.81mm RS-232 connector DB9F, DCE duplex / half-duplex Communication mode ECHO OFF - full duplex Fiber optic cable two multimode fibers ECHO ON half duplex Maximum data rate 50/125 or 62.5/ m bps Optic connectors ST type Max. range up to 6km Optical Max. line attenuation (typ) 9 db Wave length 820 nm Fiber optic cable 50/125 or 62.5/125, multimode fiber Connectors ST Maximum range 2 km Maximum data rate of RS kbit/s Maximum data rate of RS422/485 2 Mbit/s Internal terminators 12-24V (min 9, max V) Consumption Dark / Light max. 30 / 50 ma, Pull-up, pull-dowm resistors 1 k Width 55 mm of nominal power voltage 9-24V DC /500mA Length 80 mm Limit voltage values 7 30 V Height 24 mm Case metallic box 90 g Length x Width x Height 120x80x25-10 o mm to o C g + 0 o to +50 o C - 10 o to +55 o C + 0 o to +50 o C ELO+, spol. s. r.o., s r.o., CZ-397 CZ Pisek, Na Za Spravedlnosti Nadrazim 2609, 741, sales@elo.cz, tel , fax fax

2 RS422 multiplexers to optic fibre singlemode (SM) ELO E24B ELO E249, ELO E24A Two independent RS422 duplex channels Data rate kbps voltage DC 9-24 V MM-2 km, SM-15 km Multiplexer concentrate two completely independent f duplex RS422 interfaces to a pair of optic fibers. The fibers can be SINGLE MODE (SC connctors) or MULTI MODE (SC or ST connectors). Use of the multiplexers A pair of multplexers communicate over the optic fibers. If the communication is correct, the LINK indicator is alight. The maximum data rate of each channel is 230 kbps, minimum is 0. Multiplexer does not need any adjusting. The 120 Ω internal terminators can be connected to all RS422 inputs and outputs. Modem ELO E24B is designed for singlemode fibers 9/125 µm. Its range is typically 15 km, optic connectors are. For multimode cables 50/125 µm or 62.5/125 µm there are models ELO E24A with SC connectors and ELO E249 with ST ones. 2x Tx, 2x Rx Type of RS422 connector DB9F duplex Fiber optic cable E249/E24A two multimode fiber Optic connectors E249/E24A ST/ Fiber optic cable E24B two singlemode fiber Optic connectors E24B Maximum data rate of each channel 230 kbps Length x Width x Height 120 x 80 x 25 mm ELO+, spol. s r.o., CZ Pisek, Na Spravedlnosti 741, sales@elo.cz, , fax

3 RS-232 to Multimode Fiber Optic Converter ELO E146, ELO E147 Miniature case TxD, RxD transferring Max. data rate kbps voltage 6 V DC Max range 2 km RS-232 is the interface with asymmetric signals. The maximum load capacitance can be 2500 pf. It corresponds to the 50m of the typical twisted pair cable. The load impedance can be 3-7 kiloohm and it enables to induce the disturbing impulses even from the soft supplies into the cable. The asymmetric signals can not eliminate the influence of the signal grand s potential drifts. Therefore the RS-232 interface is destined for the point-topoint connection at 15 m distance. The end devices (DTE) must have the same signal grand s potential. Principles of Operation ELO E146, E147 converts TxD signal to transmitting optic cable and the signal from the receiving cable converts to RxD signal. This way the full duplex connection can be realized. In the idle mode the E146 model's transmitter lights and E147, does not light. The maximum transmission speed is The control and status signals are not transmitted. There are the local loops RTS-CTS and DTR-DSR-DCD. Using Fiber Optic Converter The fiber optic cable is resistant against the electrical disturbances and against the influences of the atmospheric electricity. It gives the maximum protection of the DTE and the high reliability of communication. Electrical Interface Control signals RS-232 Connector Communication mode Maximum data rate RS-232 TxD a RxD, local loops RTS-CTS DTR-DSR-DCD, DB25, DCE full duplex Optical parameters Wave length 820 nm Fiber optic cable 50/125 or 62.5/125 µm multimode Connectors ST Idle state of E146 (E147) light (dark) Maximum range up to 2km Power External DC supply 6V/150mA Width 55 mm Length 75 mm Height 16 mm 40 g - 10 o to +55 o C + 0 o to +50 o C

4 RS 485 to Multimode Fibre Optic Converter ELO E171 Minimum data delay Al case - for DIN rail mounting voltage DC 9-24 V Link range 2 km Fiber Optic (SINGLE MODE and/or MULTI MODE) has been used for signal transmission in automation for communication more and more often. The main advantage of Fiber Optic is its immunity to electromagnetic interference, slight radiation and high transmission capacity Use of the converter These problems can be solved if the converter ELO E171 (MULTI MODE) is applied. ELO E171 transfers signal received from RS-485 interface to transmitting fiber of the optic cable and the signal from receiving fiber is transmitted to RS-485. Besides the signal transfer, the converter matches the full duplex fiber to the half duplex RS-485 (data-flow direction switching). Its independent operation is based on the set data rate (1200 to 11520) and data format which must be asynchronous of 10 and/or 11bits (start bit, 8 to 9 information bits, stop bit). The switching speed is sufficient to use the converter in data transmission network organized as MASTER-SLAVE and MULTI MASTER. The converter also corrects bits width distortion which could occur during transmission. For fiber optic connection optical connector ST is used as standard. differential signal AB Type and connection of RS-485 connector clamps Isolation RS-485 galvanic isolation from GND 3 kv/1 sec supply asynchronous, half-duplex Fiber optic cable two multimode fiber Optic connectors ST type Maximum data rate Length 115 mm Width 55 mm Height 24 mm 137 g

5 RS-422 / Multimode Fiber Optic Converter ELO E174 ST connectors Duplex transfer of TxD, RxD ing voltage DC 6V Al case - for DIN rail Max. range 2 km RS-422 (V.11) is a duplex interface for two devices communication. The symmetric signals are transmitted via the twisted pair and they are immune to the interference. Maximum range is 1200m which can be increased using repeaters. Use of the converter The fiber optic cable is immune to electromagnetic interference and atmospheric electricity influences, it provides maximum DTE protection and high communication reliability. The distance between devices is not more than 2-3km so using multimode fibers is economically convenient in automation. Maximum data rate limit is kbps. LED diodes indicate the transmitted and received signal. Power supply connection To supply the converter, the external power supply of 6V via SCJ 2.5mm connector (yellow diode labeled 6V indicates it) or via 9 contact (IN+8V) is used, e.g. from the DTE. The green diode labeled 8V indicates this supply. The DTE receives the external supply information via OUT+5V signal, indicated by the LED of the same name. This lay out enables to back up the converter supply. The external supply is isolated from the RS-422 link. Maximum take off is 170mA. The converter transfers Tx signal of the RS-422 interface to the transmitting optic fiber and copies it from the receiving optic fiber to Rx of the RS-422 interface. Interface RS-422 connector Transmission mode RS-422 DB9F full duplex Optical parameters Wavelength 820mm, multimode fibre Optic fiber 50/125 or 62.5/125 Connectors ST Fiber optic cable two single mode fibers 9/125 µm Maximum data rate Length external DC supply of 6V/200mA galv isolation DC supply of 8V/170 ma (from DTE) 80mm Width 55mm Height 20mm 80g

6 RS-485 / TTL / Multimode Fiber Optic Converter ELO E175 ST connectors Half-duplex transfer ing voltage DC 6V Al case - for DIN rail Max. range 2 km RS-485 is a half-duplex interface with the symmetric signals. Up to 32 partners can be interconnected via the twisted pair. The maximum range is 1200 m which can be increased using repeaters. TTL signals are mainly designed to the logic components interconnection inside the board. The wire length can be only a few meters. Use of the converter The fiber optic cable is immune to electromagnetic interference and atmospheric electricity influences, it provides maximum DTE protection and high communication reliability. The ECHO mode switch is provided with this converter. This mode is mainly suitable for more devices connection into the optic loop network. When ECHO=ON mode (DTE is SLAVE) the data from the receiving optic fiber are copied to the transmitting optic fiber. In case DTE is MASTER the ECHO is disabled ECHO=OFF. When in RS-485 mode the converter works in the halfduplex mode. The signal from the receiving optic fiber copies to the RS-485 link. The DTE provided with RS-485 interface receives the data. If the DTE is to transmit the RTS signal has to be set and then the data from the DTE flow through the RS-485 link to the optic transmitter. When in TTL mode the DTE converter connection is duplex. In ECHO=ON mode the data received from the optic line are always copied to the DTE and the optic transmitter. The data collision can occur if the DTE transmits the data at the same time when the data from the remote DTE are received. For this reason, the remote and local DTE must not transmit concurrently. The SW DTE device has to solve these situations. When only two DTE are interconnected the ECHO receiver has to be in OFF position. Power supply connection To supply the converter, the external power supply of 6V via SCJ 2.5mm connector (yellow diode labelled 6V indicates it) or from the DTE via 9 contact (IN+8V) is used. This lay out enables to back up the converter supply. The green diode labelled 8V indicates the supply from the DTE. The DTE and the user receive the external power supply information via OUT+5V signal. The external supply of 6V is isolated from the RS-485/TTL link. The maximum take off is 170mA. Interface RS-485/TTL Control signals RTS in RS-485 mode None in TTL mode RS-485/TTL connector DB9F Transmission mode TTL - full duplex RS-485 half-duplex Optical parameters Wavelength 820 nm, multimode fiber Optic fiber 50/125 or 62.5/125 µm Connectors ST Maximum data rate Width Length Height external DC supply of 6V/200mA galv.isolation, DC supply of 8V/170mA from DTE 55 mm 80 mm 20 mm 80 g - 10 o to + 55 o C + 0 o to +50 o C

7 Adapters for duplex transmission of binary signals over the multimode fiber optic ELO E203, E207, E208 Bidirectional transfer of 5 binary signals Data error and Link error indication DIN rail mounting voltage 9 24 V DC nominal p to 2 km Multimode cable 50/125 or 62,5/125 m Data transmission over the fiber optic is suitable in such applications, where noise induction in metal conductors can interfere with transferred data or even destroy devices. It may be also appropriate to connect devices with high voltage potential over the fiber optic link. Use of the multiplexers Binary data signaling is still concern of the fire protection and security field. It is usable in automation application too. Adapter can be used for fault signalization, fiber optic line breakdown detection, to blackout or brownout of the remote station indication. Inputs are galvanic isolated. They are fitted with input current limitation to 6 ma. Outputs can be fitted with classic relay (60V AC/DC, 5A) model ELO E208 or with SSR (Solid State Relay, MOSFET technology, 0.5A, 48V DC / 24V AC) models ELO E203 and E207. State of every input IN1.. IN5 is periodically sampled, coded and transmitted from input unit over the optical link. Receiver unit decodes received packets and sets outputs O1.. O5. Furthermore it indicate validity of the received data by ON state on the Valid output as an unit is checking transferred data. If there is any packet error detected, the Valid output switches off, whereas data outputs stay in last good known conditions. If the error lasts for a few seconds, all outputs are subsequently switched off. Binary inputs galvanic isolated Log V Log. 1 > 4.5 V Input current limiter 6 ma Binary outputs SSR, or electromechanical relay Max. switched current SSR/relay 0.5/5 A Max.switched voltage SSR, 24/30 V AC Max.switched voltage - relay 48/60 V DC Optic fibers multimode 50/125 or 62,5/125 m Model ELO E207 contains a 24V/40mA supply, which is galvanic isolated (clamps Src ). It is suitable if it is necessary to transmit for instance a relay contacts without potential. Input & output states are indicated on the front panel altogether with processor status and eventually transmission error. Optic connectors ST Typical range 2 km Nominal supply voltage 9 24 V DC Limit supply voltages Power take off (24 V) typ. 150 ma, max. 400 ma Wave length 820 nm Dimensions W x L x H 22,5 x 108 x120 mm 140 g Storage temperature - 10 o to +50 o C + 5 o to +50 o C ELO+, spol. s r.o., CZ Pisek,Za Nadrazim 2609, sales@elo.cz, , fax

8 Adapters for simplex transmission of binary signals over the multimode fiber optic ELO E204, E205, E206 Unidirect transfer of 5 binary signals Data error and Link error indication DIN rail mounting voltage 9 24 V DC nominal p to 2 km Multimode fibre 50/125 or 62,5/125 m Data transmission over the fiber optic is suitable in such applications, where noise induction in metal conductors can interfere with transferred data or even destroy devices. It may be also appropriate to connect devices with high voltage potential over the fiber optic link. Use of the multiplexers Binary data signaling is still concern of the fire protection and security field. It is usable in automation application too. Models ELO E204 and ELO E205 are multiplexing five binary input signals. Inputs are periodically sampled, coded and transmitted from input unit over the optical link. Inputs are galvanic isolated. They are fitted with input current limitation to 6 ma. Model ELO E205 contains a 24V/40mA supply, which is galvanic isolated (clamps Src ). It is suitable if it is necessary to transmit for instance a relay contact without potential. Receiver ELO E206 decodes received packets and sets outputs O1.. O5. Furthermore it indicate validity of the received data by ON state on the Valid output as an unit is checking transferred data. If there is any packet error detected, the Valid output switches off, whereas data outputs stay in last good known conditions. If the error lasts for a few seconds, all outputs are subsequently switched off. Input & output states are indicated on the front panel altogether with processor status and eventually transmission error. Outputs are fitted with SSR (Solid State Relay), MOSFET technology, 0.5A, 48V DC / 24V AC). Binary inputs Log. 0 Log. 1 Input current limiter Binary outputs Max. switched current Max. switched voltage Optic fiber galvanic isolated 0 3 V > 4,5 V 6 ma SSR, 0.5 A 48 V DC or 24 V AC multimode 50/125 or 62.5/125 m Optic connectors ST Typical range 2 km Nominal supply voltage 9 24 V DC Limit supply voltages Power take off (24 V) typ. 150 ma, max. 400 ma Wave length 820 nm Dimensions W x L x H 22,5 x 108 x120 mm 140 g Storage temperature - 10 o to +50 o C + 5 o to +50 o C ELO+, spol. s r.o., CZ Pisek,Za Nadrazim 2609, sales@elo.cz, , fax

9 Communication adapter virtual COM port over the USB to multimode optics fiber ELO E210 Charakterictics TxD, RxD signal transmission Transfer speed max. 921,6 kb/s max. 2 km (1.25 miles) Alu cover Interference immunity Nowadays, in PC computing become more popular USB interface against RS232 serial interface because of their robustness and speed. There are converters USB to COM to connect peripherials with old RS232 interface, which altogether with software drivers adds another COM port to the PC so called Virtual Com Port, VCP. E210 converts COM port to a fiber cable over the USB interface. Use of the adapter Data transmission over the optics is electromagnetics interference immune and atmospheric electricity immune. Allows maximum protection of the connected device DTE against the potential difference, overvoltage and assures reliable communication. Also, it is difficult to eavesdrop the communication. Adapter converts data stream from receiving fiber optics to a RxD signal on the virtual COM port whereas TxD signal from COM port is transmitted to a transmitting fiber optics. No other signals are transmitted. Data transmission is indicated by two LED diodes in both direction. Adapter has two switches. A IDLE switch allows to change signal polarity in fiber optics. Switched to LIGHT position, idle state is represented by 1 in the fiber, i.e. optical transmitter lights. DARK position results 0 state in the optical cable while is in idle state. LIGHT mode can be used to detect breakdown on the data path even in idle state, so it can be used in safety systems. An ECHO Switch allows choose the mode of the optical connection between two-point or ring mode of the operation. An OFF position is intended for connection of two adapters as described in previous paragraph; while ON position sends data received from optics not only to COM port, but copies it to the transmitting optics too. It allows all members on this ring optical network to receive the data packet. Communication protocol must handle data collisions. Electrical parameters Interface USB connector Communication mode Optical parameters Wave length Optical fibre Connectors Max. data rate Max. range USB 2.0 full-speed (12Mb/s) type B - female full duplex 820 nm, multimode 50/125 nebo 62.5/125nm ST b/s 2 km s from USB interface Consumption Dark/Light max. 50 / 90 ma width 55 mm length 80 mm height 20 mm 80 g - 10 o to +55 o C + 0 o to +50 o C ELO+, spol. s r.o., CZ Pisek, Za Nadrazim 2609, sales@elo.cz, , fax

10 Modems RS232 Fibre Optic Singlemode (SM) ELO E242 ELO E240, ELO E241 DTE-DCE switch Optic line watch dog voltage DC 9-24 V MM-2 km, SM-15 km Modems are the converters of RS232 data signals to optic fiber and back. Optic fibers can be SINGLE MODE (SC connctors) or MULTI MODE (SC or ST connectors). The modems are suitable fo tw-point connections. Use of the modems A pair of modems communicate over the optic fibers. If the communication is correct, the LINK indicator is alight. The modems are watching for the optic line and in the case of disconnection the ALARM signal has been activated. RS232 communicatin data rate can be any ranging from 0 to 230 kbps without any modem adjusting. The data format can be random too. The RS232 connector can be set to DTE or DCE mode using the switches on the back side of modem. Modem ELO E242 is designed for singlemode fibers 9/125 µm. Its range is typically 15 km, optic connectors are SC type. For multimode cables 50/125 µm or 62.5/125 µm there are models ELO E241 with SC connectors and ELO E240 with ST ones. TxD, RxD Type and connection of RS232 conn. DB9F, DTE/DCE duplex Fiber optic cable E240/E241 two multimode fiber Optic connectors E240/E241 ST/ Fiber optic cable E242 two singlemode fiber Optic connectors E242 Maximum data rate 120 mm Length Width 80 mm Height 25 mm

11 Modems RS232 Fibre Optic Singlemode (SM) ELO E242 ELO E240, ELO E241 DTE-DCE switch Optic line watch dog voltage DC 9-24 V MM-2 km, SM-15 km Modems are the converters of RS232 data signals to optic fiber and back. Optic fibers can be SINGLE MODE (SC connctors) or MULTI MODE (SC or ST connectors). The modems are suitable fo tw-point connections. Use of the modems A pair of modems communicate over the optic fibers. If the communication is correct, the LINK indicator is alight. The modems are watching for the optic line and in the case of disconnection the ALARM signal has been activated. RS232 communicatin data rate can be any ranging from 0 to 230 kbps without any modem adjusting. The data format can be random too. The RS232 connector can be set to DTE or DCE mode using the switches on the back side of modem. Modem ELO E242 is designed for singlemode fibers 9/125 µm. Its range is typically 15 km, optic connectors are SC type. For multimode cables 50/125 µm or 62.5/125 µm there are models ELO E241 with SC connectors and ELO E240 with ST ones. TxD, RxD Type and connection of RS232 conn. DB9F, DTE/DCE duplex Fiber optic cable E240/E241 two multimode fiber Optic connectors E240/E241 ST/ Fiber optic cable E242 two singlemode fiber Optic connectors E242 Maximum data rate 120 mm Length Width 80 mm Height 25 mm

12 Modems RS232 Fibre Optic Singlemode (SM) ELO E242 ELO E240, ELO E241 DTE-DCE switch Optic line watch dog voltage DC 9-24 V MM-2 km, SM-15 km Modems are the converters of RS232 data signals to optic fiber and back. Optic fibers can be SINGLE MODE (SC connctors) or MULTI MODE (SC or ST connectors). The modems are suitable fo tw-point connections. Use of the modems A pair of modems communicate over the optic fibers. If the communication is correct, the LINK indicator is alight. The modems are watching for the optic line and in the case of disconnection the ALARM signal has been activated. RS232 communicatin data rate can be any ranging from 0 to 230 kbps without any modem adjusting. The data format can be random too. The RS232 connector can be set to DTE or DCE mode using the switches on the back side of modem. Modem ELO E242 is designed for singlemode fibers 9/125 µm. Its range is typically 15 km, optic connectors are SC type. For multimode cables 50/125 µm or 62.5/125 µm there are models ELO E241 with SC connectors and ELO E240 with ST ones. TxD, RxD Type and connection of RS232 conn. DB9F, DTE/DCE duplex Fiber optic cable E240/E241 two multimode fiber Optic connectors E240/E241 ST/ Fiber optic cable E242 two singlemode fiber Optic connectors E242 Maximum data rate 120 mm Length Width 80 mm Height 25 mm

13 Modems RS485/422 to optic fibre singlemode (SM) ELO E245 ELO E243, ELO E244 Data rate up to 1.5 Mbps Optic line watch dog voltage DC 9-24 V MM-2 km, SM-15 km Modems are the converters of duplex RS422 interface and half-duplex RS485 bus to optic fiber and back. Optic fibers can be SINGLE MODE (SC connctors) or MULTI MODE (SC or ST connectors). Use of the modems A pair of modems communicate over the optic fibers. If the communication is correct, the LINK indicator is alight. The modems are watching for the optic line and in the case of disconnection the ALARM signal has been activated. The maximum data rate is 5 Mbps in duplex RS422 mode without any modem adjusting. If the half-duplex mode is selected, the communicatin data rate and data format must be set properly. The data rate can be from 4.8 to 1500 kbps, data format 8 or 9 bits. Using the switches on the back side of modem the internal 120 Ω resistors can be connected to RS485/422 outputs and inputs. Modem ELO E245 is designed for singlemode fibers 9/125 µm. Its range is typically 15 km, optic connectors are SC type. For multimode cables 50/125 µm or 62.5/125 µm there are models ELO E244 with SC connectors and ELO E243 with ST ones. Tx, Rx or TxRx Type of RS485/422 connector DB9F duplex / half-duplex Fiber optic cable E243/E244 two multimode fiber Optic connectors E243/E244 ST/ Fiber optic cable E245 two singlemode fiber Optic connectors E245 Maximum data rate RS422 5 Mbps Maximum data rate RS Mbps 4.8 kbps Length x Width x Height 120 x 80 x 25 mm

14 Modems RS485/422 to optic fibre singlemode (SM) ELO E245 ELO E243, ELO E244 Data rate up to 1.5 Mbps Optic line watch dog voltage DC 9-24 V MM-2 km, SM-15 km Modems are the converters of duplex RS422 interface and half-duplex RS485 bus to optic fiber and back. Optic fibers can be SINGLE MODE (SC connctors) or MULTI MODE (SC or ST connectors). Use of the modems A pair of modems communicate over the optic fibers. If the communication is correct, the LINK indicator is alight. The modems are watching for the optic line and in the case of disconnection the ALARM signal has been activated. The maximum data rate is 5 Mbps in duplex RS422 mode without any modem adjusting. If the half-duplex mode is selected, the communicatin data rate and data format must be set properly. The data rate can be from 4.8 to 1500 kbps, data format 8 or 9 bits. Using the switches on the back side of modem the internal 120 Ω resistors can be connected to RS485/422 outputs and inputs. Modem ELO E245 is designed for singlemode fibers 9/125 µm. Its range is typically 15 km, optic connectors are SC type. For multimode cables 50/125 µm or 62.5/125 µm there are models ELO E244 with SC connectors and ELO E243 with ST ones. Tx, Rx or TxRx Type of RS485/422 connector DB9F duplex / half-duplex Fiber optic cable E243/E244 two multimode fiber Optic connectors E243/E244 ST/ Fiber optic cable E245 two singlemode fiber Optic connectors E245 Maximum data rate RS422 5 Mbps Maximum data rate RS Mbps 4.8 kbps Length x Width x Height 120 x 80 x 25 mm

15 RS232 multiplexers to optic fibre singlemode (SM) ELO E248 ELO E246, ELO E247 Four independent RS232 duplex channels Data rate kbps voltage DC 9-24 V MM-2 km, SM-15 km Multiplexer concentrate four completely independent f duplex RS232 interfaces to a pair of optic fibers. The fibers can be SINGLE MODE (SC connctors) or MULTI MODE (SC or ST connectors). Use of the multiplexers A pair of multplexers communicate over the optic fibers. If the communication is correct, the LINK indicator is alight. The maximum data rate of each channel is 230 kbps, minimum is 0. Multiplexer does not need any adjusting. The contacts of RS232 connector are not used according RS232 standards. To get the standard ELO E24E (OCTOPUS) cable with four DB9F DCE connectors must be used. Modem ELO E248 is designed for singlemode fibers 9/125 µm. Its range is typically 15 km, optic connectors are SC type. For multimode cables 50/125 µm or 62.5/125 µm there are models ELO E247 with SC connectors and ELO E246 with ST ones. 4x TxD, 4x RxD Type of RS232 connector DB9F duplex Fiber optic cable E246/E247 two multimode fiber Optic connectors E246/E247 ST/ Fiber optic cable E248 two singlemode fiber Optic connectors E248 Maximum data rate of each channel 230 kbps Length x Width x Height 120 x 80 x 25 mm ELO+, spol. s r.o., CZ Pisek, Na Spravedlnosti 741, sales@elo.cz, , fax

16 RS232 multiplexers to optic fibre singlemode (SM) ELO E248 ELO E246, ELO E247 Four independent RS232 duplex channels Data rate kbps voltage DC 9-24 V MM-2 km, SM-15 km Multiplexer concentrate four completely independent f duplex RS232 interfaces to a pair of optic fibers. The fibers can be SINGLE MODE (SC connctors) or MULTI MODE (SC or ST connectors). Use of the multiplexers A pair of multplexers communicate over the optic fibers. If the communication is correct, the LINK indicator is alight. The maximum data rate of each channel is 230 kbps, minimum is 0. Multiplexer does not need any adjusting. The contacts of RS232 connector are not used according RS232 standards. To get the standard ELO E24E (OCTOPUS) cable with four DB9F DCE connectors must be used. Modem ELO E248 is designed for singlemode fibers 9/125 µm. Its range is typically 15 km, optic connectors are SC type. For multimode cables 50/125 µm or 62.5/125 µm there are models ELO E247 with SC connectors and ELO E246 with ST ones. 4x TxD, 4x RxD Type of RS232 connector DB9F duplex Fiber optic cable E246/E247 two multimode fiber Optic connectors E246/E247 ST/ Fiber optic cable E248 two singlemode fiber Optic connectors E248 Maximum data rate of each channel 230 kbps Length x Width x Height 120 x 80 x 25 mm ELO+, spol. s r.o., CZ Pisek, Na Spravedlnosti 741, sales@elo.cz, , fax

17 RS422 multiplexers to optic fibre singlemode (SM) ELO E24B ELO E249, ELO E24A Two independent RS422 duplex channels Data rate kbps voltage DC 9-24 V MM-2 km, SM-15 km Multiplexer concentrate two completely independent f duplex RS422 interfaces to a pair of optic fibers. The fibers can be SINGLE MODE (SC connctors) or MULTI MODE (SC or ST connectors). Use of the multiplexers A pair of multplexers communicate over the optic fibers. If the communication is correct, the LINK indicator is alight. The maximum data rate of each channel is 230 kbps, minimum is 0. Multiplexer does not need any adjusting. The 120 Ω internal terminators can be connected to all RS422 inputs and outputs. Modem ELO E24B is designed for singlemode fibers 9/125 µm. Its range is typically 15 km, optic connectors are. For multimode cables 50/125 µm or 62.5/125 µm there are models ELO E24A with SC connectors and ELO E249 with ST ones. 2x Tx, 2x Rx Type of RS422 connector DB9F duplex Fiber optic cable E249/E24A two multimode fiber Optic connectors E249/E24A ST/ Fiber optic cable E24B two singlemode fiber Optic connectors E24B Maximum data rate of each channel 230 kbps Length x Width x Height 120 x 80 x 25 mm ELO+, spol. s r.o., CZ Pisek, Na Spravedlnosti 741, sales@elo.cz, , fax

RS 485/422 to Fibre Optic Modems ELO E243, ELO E244, ELO E245. Operation manual

RS 485/422 to Fibre Optic Modems ELO E243, ELO E244, ELO E245. Operation manual RS 485/422 to Fibre Optic Modems ELO E243, ELO E244, ELO E245 Operation manual 1.0 Introduction 3 2.0 Operation principles 3 3.0 Installation 3 3.1 RS422 Interface Connection 4 3.2 RS485 Interface Connection

More information

Binary signal transmission adapter over the multimode fiber optic ELO E203, E204, E205, E206, E207. User manual

Binary signal transmission adapter over the multimode fiber optic ELO E203, E204, E205, E206, E207. User manual Binary signal transmission adapter over the multimode fiber optic ELO E203, E204, E205, E206, E207 User manual ELOE203ZKE002 Table of contents: Table of contents: 2 1.0 Introduction 2 1.1 Application 2

More information

RS-232 / 20mA Interface Converter ELO E00Q. Operation manual

RS-232 / 20mA Interface Converter ELO E00Q. Operation manual RS-232 / 20mA Interface Converter ELO E00Q Operation manual 2 ELOE00QZKE001 1.0 Introduction 4 1.1 Use of the converter 4 2.0 Operation principles 4 3.0 Installation 4 3.1 Converter connection to RS-232

More information

Concept of Serial Communication

Concept of Serial Communication Concept of Serial Communication Agenda Serial v.s. Parallel Simplex, Half Duplex, Full Duplex Communication RS-485 Advantage over RS-232 Serial v.s. Parallel Application: How to Measure the temperature

More information

Lecture #3 RS232 & 485 protocols

Lecture #3 RS232 & 485 protocols SPRING 2015 Integrated Technical Education Cluster At AlAmeeria E-626-A Data Communication and Industrial Networks (DC-IN) Lecture #3 RS232 & 485 protocols Instructor: Dr. Ahmad El-Banna 1 Agenda What

More information

PRODUCT INFORMATION B&B ELECTRONICS. Port-Powered RS-232 Fiber Optic Modem with Handshake Support. Model 9PFLST. Description. RS-232 Connections

PRODUCT INFORMATION B&B ELECTRONICS. Port-Powered RS-232 Fiber Optic Modem with Handshake Support. Model 9PFLST. Description. RS-232 Connections -01-1/ 00 by B&B Electronics. All rights reserved. Model Port-Powered RS- Fiber Optic Modem with Handshake Support Description The allows any two pieces of RS- asynchronous serial equipment to communicate

More information

A50/A51/A60. June 2008 (4th Edition) All Rights Reserved

A50/A51/A60. June 2008 (4th Edition) All Rights Reserved A50/A51/A60 June 2008 (4th Edition) All Rights Reserved Part I - A50/A51 RS-232 to RS-422/RS-485 Converter A50/A51 RS-232 to RS-422/RS-485 Bidirectional Converter Part II - A60 RS-232 Surge Protection

More information

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V

More information

ADA-1028L. User manual ADA-1028L. RS232 to Current Loop 2-wire CLO Converter. 1 io_ada-1028l_v.1.10_en. Copyright CEL-MAR sp.j.

ADA-1028L. User manual ADA-1028L. RS232 to Current Loop 2-wire CLO Converter. 1 io_ada-1028l_v.1.10_en. Copyright CEL-MAR sp.j. User manual ADA-1028L to Current Loop 2-wire Converter Copyright 2001-2017 CEL-MAR sp.j. 1 io_ada-1028l_v.1.10_en Contents 1. GENERAL INFORMATION... 3 1.1. WARRANTED INFORMATION... 3 1.2. GENERAL CONDITIONS

More information

Universal RS232/CMOS to RS422/RS485 Converter

Universal RS232/CMOS to RS422/RS485 Converter TOSHIBA INTERNATIONAL CORPORATION Universal RS232/CMOS to RS422/RS485 Converter Rev No.: 2 Page No.: 1 RS232/CMOS to RS422/RS485 Converter converts RS232/CMOS lines to balanced RS422 or RS485 signals.

More information

FOM-5A, 6A Asynchronous Fiber Optic Modems

FOM-5A, 6A Asynchronous Fiber Optic Modems ORDERING FOM-5A/*/+ Asynchronous Sub-miniature Fiber Optic Modem FOM-6A/*/+/# Asynchronous Miniature Fiber Optic Modem * Specify: F for female 25-pin connector M for male 25-pin connector + Specify: ST

More information

ADA User manual ADA RS-232 to RS-485 / RS-422 Converter

ADA User manual ADA RS-232 to RS-485 / RS-422 Converter User manual RS- to RS- / RS- Converter Copyright 001-01 CEL-MAR sp.j. 1 io_ada-100_v._en Contents 1. GENERAL INFORMATION... 1.1. WARRANTED INFORMATION... 1.. GENERAL CONDITIONS FOR SAFE USE... 1.. CE LABEL...

More information

Modem 9600 baud 500FSD11 EDS500 series - FSK modems

Modem 9600 baud 500FSD11 EDS500 series - FSK modems Data sheet Modem 9600 baud 500FSD11 EDS500 series - FSK modems Voice frequency telegraphy device (VFT) Transparent up to 9600 baud Can be connected to 23WT24 DIN rail mounted 24...60 V DC supply voltage

More information

RS232 to RS485 or RS422 line converter with isolation. >>> Distribucion: ER-Soft, S.A. Tel: <<<

RS232 to RS485 or RS422 line converter with isolation. >>> Distribucion: ER-Soft, S.A.  Tel: <<< RS232 RS485/422 RS232 to RS485 or RS422 line converter with isolation >>> Distribucion: ER-Soft, S.A. www.er-soft.com info@er-soft.com Tel: +34 916-408-408

More information

Universal Converter Covers All the Bases- RS-232 to 4-wire RS-422, 2-wire or 4-wire RS-485

Universal Converter Covers All the Bases- RS-232 to 4-wire RS-422, 2-wire or 4-wire RS-485 4WSD9R0712-1/4 Model 4WSD9R Universal Converter Covers All the Bases- RS-232 to 4-wire RS-422, 2-wire or 4-wire RS-485 The 4WSD9R Universal Converter is a port-powered or externally powered two-channel

More information

Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter

Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter Hardware Installation Guide First Edition, August 2013 2013 Moxa Inc. All rights reserved. P/N: 1802012800011 Introduction The ICF-1280I series

More information

Serial Communications RS232, RS485, RS422

Serial Communications RS232, RS485, RS422 Technical Brief AN236 Technical Brief AN236Rev A Serial Communications RS232, RS485, RS422 By John Sonnenberg S u m m a r y Electronic communications is all about interlinking circuits (processors or other

More information

RS-232 Electrical Specifications and a Typical Connection

RS-232 Electrical Specifications and a Typical Connection Maxim > Design Support > Technical Documents > Tutorials > Interface Circuits > APP 723 Keywords: RS-232, rs232, RS-422, rs422, RS-485, rs485, RS-232 port powered, RS-232 to RS-485 conversion, daisy chain,

More information

Selection guide. Communication accessories. Communication accessory selection guide. Characteristics

Selection guide. Communication accessories. Communication accessory selection guide. Characteristics Communication accessories Selection guide There are 2 types of Sepam communication accessories: b communication interfaces, which are essential for connecting Sepam to the communication network b converters

More information

Cable and Port Specifications

Cable and Port Specifications APPENDIX D This appendix includes the following information: Cables and Adapters Provided, page D-1 Console Port, page D-2 COM1 Port, page D-3 MGMT 10/100 Ethernet Port, page D-5 SFP Transceiver Specifications,

More information

Miniature Synchronous Multipoint Modems

Miniature Synchronous Multipoint Modems ME1735A-F JULY 2003 Miniature Synchronous Multipoint Modems CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support 24 hours

More information

There are many important factors when trying to achieve good, reliable communications between 2 devices.

There are many important factors when trying to achieve good, reliable communications between 2 devices. APPLICATION NOTE THIS INFORMATION PROVIDED BY AUTOMATIONDIRECT.COM TECHNICAL SUPPORT These documents are provided by our technical support department to assist others. We do not guarantee that the data

More information

Serial Input/Output. Lecturer: Sri Parameswaran Notes by: Annie Guo

Serial Input/Output. Lecturer: Sri Parameswaran Notes by: Annie Guo Serial Input/Output Lecturer: Sri Parameswaran Notes by: Annie Guo 1 Serial communication Concepts Standards USART in AVR Lecture overview 2 Why Serial I/O? Problems with Parallel I/O: Needs a wire for

More information

The I-2532 CAN to Fiber Converter

The I-2532 CAN to Fiber Converter The I-2532 CAN to Fiber Converter User s Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date of delivery to the

More information

ADA User manual ADA Multimode Fibre-Optic to Current Loop Converter

ADA User manual ADA Multimode Fibre-Optic to Current Loop Converter User manual Multimode Fibre-Optic to Converter Copyright 2001-2017 CEL-MAR sp.j. 1 io_ada-7021_v1.02_en Contents 1.GENERAL INFORMATION... 3 1.1.WARRANTED INFORMATION... 3 1.2.GENERAL CONDITIONS FOR SAFE

More information

Electronics / Water analogy. Resistor. Inductance. Capacitor. Water Electronics Energy - Energy Pressure - Voltage Flow - Current Volume - Charge

Electronics / Water analogy. Resistor. Inductance. Capacitor. Water Electronics Energy - Energy Pressure - Voltage Flow - Current Volume - Charge Electronics / Water analogy Water Electronics Energy - Energy Pressure - Voltage Flow - Current Volume - Charge Resistor U = R * I 1 Capacitor U 1 i dt C U L di dt Inductance Turbine Flywheel Diode Transistor

More information

MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE

MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE Distribué par : Contact : hvssystem@hvssystem.com Tél : 0326824929 Fax : 0326851908 Siège social : 2 rue René Laennec 51500 Taissy France www.hvssystem.com MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE

More information

M9606. FSK Modem. 5C Communications Inc.

M9606. FSK Modem. 5C Communications Inc. FSK Modem Application modem is a voice-frequency telegraphy unit (VFT unit) which operates according to the principle of binary frequency shift keying. It is designed especially for Power Industrial applications.

More information

SMARTALPHA RF TRANSCEIVER

SMARTALPHA RF TRANSCEIVER SMARTALPHA RF TRANSCEIVER Intelligent RF Modem Module RF Data Rates to 19200bps Up to 300 metres Range Programmable to 433, 868, or 915MHz Selectable Narrowband RF Channels Crystal Controlled RF Design

More information

APPLICATION BULLETIN. SERIAL BACKGROUNDER (Serial 101) AB23-1. ICS ICS ELECTRONICS division of Systems West Inc. INTRODUCTION CHAPTER 2 - DATA FORMAT

APPLICATION BULLETIN. SERIAL BACKGROUNDER (Serial 101) AB23-1. ICS ICS ELECTRONICS division of Systems West Inc. INTRODUCTION CHAPTER 2 - DATA FORMAT ICS ICS ELECTRONICS division of Systems West Inc. AB- APPLICATION BULLETIN SERIAL BACKGROUNDER (Serial 0) INTRODUCTION Serial data communication is the most common means of transmitting data from one point

More information

M-Bus Master MultiPort 250L Installation and User Guide

M-Bus Master MultiPort 250L Installation and User Guide Installation and User Guide Kamstrup A/S Industrivej 28, Stilling DK-8660 Skanderborg T: +45 89 93 10 00 info@kamstrup.com kamstrup.com Contents 1 Introduction 3 1.1 Design 3 2 Functionality 4 2.1 Overview

More information

E550 Series 2. Electricity Meters IEC/MID Industrial and Commercial ZMG400AR/CR. Technical Data

E550 Series 2. Electricity Meters IEC/MID Industrial and Commercial ZMG400AR/CR. Technical Data Electricity Meters IEC/MID Industrial and Commercial ZMG400AR/CR E550 Series 2 Technical Data Building on its tradition of industrial meters, Landis+Gyr is now bringing out the E550 Series 2, the latest

More information

E550 Series 2. Electricity Meters IEC/MID Industrial and Commercial ZMG310AR/CR. Technical Data

E550 Series 2. Electricity Meters IEC/MID Industrial and Commercial ZMG310AR/CR. Technical Data Electricity Meters IEC/MID Industrial and Commercial ZMG310AR/CR E550 Series 2 Technical Data Building on its tradition of industrial meters, Landis+Gyr is now bringing out the E550 Series 2, the latest

More information

Transceiver, Chassis Connectors, and Cable and Adapter Specifications

Transceiver, Chassis Connectors, and Cable and Adapter Specifications APPENDIXB Transceiver, Chassis Connectors, and Cable and Adapter Specifications Revised: January 4, 2012 This appendix covers the transceivers supported by the Catalyst 4948E and the Catalyst 4948E-F switches,

More information

Since 1987 Developed, Created and Made in Spain NDV6/ND6V VIDEO & DATA TRANSCEIVER, AUDIO & CONTACT

Since 1987 Developed, Created and Made in Spain NDV6/ND6V VIDEO & DATA TRANSCEIVER, AUDIO & CONTACT Since 987 Developed, Created and Made in Spain NDV6/ND6V VIDEO & DATA TRANSCEIVER, AUDIO & CONTACT CONTENTS General functionality and features of the equipment. Technical specifications. Application. Connection

More information

Non-Powered Interface Converters RS-232 to RS-530 RS-422 to V.35 RS-232 to RS-485 RS-232 to RS-422/RS-449

Non-Powered Interface Converters RS-232 to RS-530 RS-422 to V.35 RS-232 to RS-485 RS-232 to RS-422/RS-449 IC237A IC482A JUNE 1995 IC486A IC487A-F Non-Powered Interface Converters S-232 to S-530 S-422 to V.35 S-232 to S-485 S-232 to S-422/S-449 CUSTOME SUPPOT INFOMATION Order toll-free in the U.S. 24 hours,

More information

CONV232/422 SERIAL DATA CONVERTER

CONV232/422 SERIAL DATA CONVERTER ACCES I/O PRODUCTS I. 06 Roselle St., San Diego CA 9-06 Tel (88)0-99 FAX (88)0-7 CONV/ SERIAL DATA CONVERTER DATA SHEET Model CONV/ is a bidirectional RS- to RS- converter. It converts full-duplex, single

More information

4 Channel 4~20mA / 0~10VDC Analog DIN Fiber Link System

4 Channel 4~20mA / 0~10VDC Analog DIN Fiber Link System USER GUIDE RLH Industries, Inc. The leader in rugged fiber optic technology. U-026 2017A-0420 4 Channel 4~20mA / 0~10VDC Analog DIN Fiber Link System SYSTEM INSTALLATION INFORMATION Description The DIN

More information

Modem 1200 baud 500FSD10 EDS500 series - FSK modems

Modem 1200 baud 500FSD10 EDS500 series - FSK modems Manual Modem 1200 baud 500FSD10 EDS500 series - FSK modems Application, characteristics and technical data have to be taken from the hardware data sheet: 500FSD10 Data sheet 1KGT150982 Operation The 500FSD10

More information

Chapter 12: Digital Modulation and Modems

Chapter 12: Digital Modulation and Modems Chapter 12: Digital Modulation and Modems MULTIPLE CHOICE 1. FSK stands for: a. Full-Shift Keying c. Full-Signal Keying b. Frequency-Shift Keying d. none of the above 2. PSK stands for: a. Pulse-Signal

More information

DTR-xxx-LC & DTR-xxx-LS. 3.3 Volt 2x5 LC connector OC-3 & OC-12 LED Transceivers. Parameter Symbol Minimum Maximum Units Storage Temperature T st

DTR-xxx-LC & DTR-xxx-LS. 3.3 Volt 2x5 LC connector OC-3 & OC-12 LED Transceivers. Parameter Symbol Minimum Maximum Units Storage Temperature T st OCP ' DTR-xxx-LC & DTR-xxx-LS 3.3 Volt 2x5 LC connector OC-3 & OC-2 LED Transceivers Features þ Designed for ATM/SONET/SDH OC-3 (56 Mb/s) & OC-2 (622 Mb/s) þ Multi-sourced 0-pin (2x5) SFF (Small Form Factor)

More information

DigiPoints Volume 1. Student Workbook. Module 2 Modem Overview

DigiPoints Volume 1. Student Workbook. Module 2 Modem Overview Modem Overview Page 2.1 DigiPoints Volume 1 Module 2 Modem Overview Summary One of the potential advantages the cable telecommunications industry has is the ability to carry data signals at speeds significantly

More information

DSP4xxFP SA USER S MANUAL. A01561 Rev. A. This Manual covers all configurations of the DSP4xxSA Modem with the Serial Number SA and up.

DSP4xxFP SA USER S MANUAL. A01561 Rev. A. This Manual covers all configurations of the DSP4xxSA Modem with the Serial Number SA and up. DSP4xxFP SA USER S MANUAL A01561 Rev. A This Manual covers all configurations of the DSP4xxSA Modem with the Serial Number SA700425 and up. DSP4xxSA User s Manual A01561 Rev. X Proprietary Data This document

More information

Serial data converters ILPH range

Serial data converters ILPH range ILPH range Content Presentation... 214 Product overview... 21 ILPH S 232 / S 422-48 - Without galvanic isolation... 216 ILPH S 232 / S 422-48 - With galvanic isolation... 217 ILPH S 232 / S 422-48 - 3

More information

SWT 3000 Teleprotection technical data siemens.com

SWT 3000 Teleprotection technical data siemens.com Power network telecommunication SWT 3000 Teleprotection technical data siemens.com Sustainable success for high-voltage power networks The SWT 3000 Teleprotection system has been the first choice for reliable

More information

2070-6A Manual A Manual. Dual 1200 baud Modem For The 2070 Controller GDI A MANUAL

2070-6A Manual A Manual. Dual 1200 baud Modem For The 2070 Controller GDI A MANUAL 2070-6A Manual 1 2070-6A Manual Dual 1200 baud Modem For The 2070 Controller GDI 2070-6A MANUAL This Manual covers Modems with the Serial numbers D700000 and up. 2070-6A Manual 2 GDI 2070-6A Manual This

More information

ROM/UDF CPU I/O I/O I/O RAM

ROM/UDF CPU I/O I/O I/O RAM DATA BUSSES INTRODUCTION The avionics systems on aircraft frequently contain general purpose computer components which perform certain processing functions, then relay this information to other systems.

More information

+5V Multiprotocol, Software-Selectable Cable Terminator

+5V Multiprotocol, Software-Selectable Cable Terminator 19-1775; Rev 0; 2/01 +5V Multiprotocol, Software-Selectable General Description The contains six software-selectable, multiprotocol cable termination networks. Each network is capable of terminating V.11

More information

Interface: Serial EIA RS-232D/CCITT V.24, DCE; RTS/CTS delay 0,8 or 64 ms (user-selectable).

Interface: Serial EIA RS-232D/CCITT V.24, DCE; RTS/CTS delay 0,8 or 64 ms (user-selectable). BLACK BOX PWR RTS TD-1 RD-1 TD-2 DCD RD-2 TEST DIG ANA REM LDM-MR 19.2 REM ANA DIG AGC 2/4 WIRE ABLE / ABLE SWITCHES 2 W 4 W 1 2 3 4 CARRIER LEVEL 0 dbm -3 dbm -6 dbm -9 dbm PIN 21 (RLB) RPF PIN 18 AN.

More information

Data transmission. 4.1 Optical transmission 173

Data transmission. 4.1 Optical transmission 173 Data transmission. Optical transmission 7 7 7 Optical transmission Glossary of technical terms 7 CS serie Serial data link - DC 76. 7 glossary of technical terms. Serial It is generally indicative of a

More information

RS-422/485 Application Note

RS-422/485 Application Note RS-422 and RS-485 Application Note RS-422/485 Application Note Cover Page Table of Contents CHAPTER 1: OVERVIEW... 1 INTRODUCTION... 1 DATA TRANSMISSION SIGNALS... 1 Unbalanced Line Drivers... 1 Balanced

More information

QuidoDuplex RS. Set for bi-directional transmission of 4 or 8 two-state signals over RS485 or RS June 2011 w w w. p a p o u c h.

QuidoDuplex RS. Set for bi-directional transmission of 4 or 8 two-state signals over RS485 or RS June 2011 w w w. p a p o u c h. Set for bi-directional transmission of 4 or 8 two-state signals over RS485 or RS232 7. June 2011 w w w. p a p o u c h. c o m Q uidoduplex RS Datasheet Created: 3/16/2006 Last update: 6/7/2011 8:57 AM Number

More information

ZCS485 User s Manual. Version ZYPEX, Inc.

ZCS485 User s Manual. Version ZYPEX, Inc. ZCS485 User s Manual Version 2.2 2004 ZYPEX, Inc. Table of Contents Product Description 1 ZCS485 Configuration & Setup 2 4-wire Operation 2 2-wire Operation 2 Dual Port Operation 2 Carrier Detect 2 Transmitter

More information

Model 4xx. Plug-in Series Of FSK Modems USER GUIDE. (TI) 20 Jan 06 DWG: A GDI COMMUNICATIONS LLC PO Box I-80 Exit 1 Verdi, NV 89439

Model 4xx. Plug-in Series Of FSK Modems USER GUIDE. (TI) 20 Jan 06 DWG: A GDI COMMUNICATIONS LLC PO Box I-80 Exit 1 Verdi, NV 89439 Model 4xx Plug-in Series Of FSK s USER GUIDE (TI) 20 Jan 06 DWG: A01164 GDI COMMUNICATIONS LLC PO Box 1330 280 I-80 Exit 1 Verdi, NV 89439 Phone: (775) 345-8000 Fax: (775) 345-8010 Web: www.sgdi.com Email:

More information

F290X / F293X FOM II Series Fiber Optic Isolator Technical Manual

F290X / F293X FOM II Series Fiber Optic Isolator Technical Manual F290X / F293X FOM II Series Fiber Optic Isolator Technical Manual Revision G Copyright 2017 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com E031130243 PROPRIETARY DATA All data

More information

LDM85. Fiber Optic Modem. Description. Features. Specifications

LDM85. Fiber Optic Modem. Description. Features. Specifications 6 Fiber Optic Modem Description he is a small, inexpensive fiber optic transmitter/receiver. It features a complete S- port as well as high speed L/S- /S- data transmit and receive. It is capable of data

More information

Interface converter G kbit/sec

Interface converter G kbit/sec converter User s Guide 12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901 Interface converter G.703.1 64 kbit/sec Features Maximum line attenuation

More information

JZ878 RF Data Radio. User s Manual

JZ878 RF Data Radio. User s Manual JZ878 RF Data Radio User s Manual SHEN JIZHUO TECHNOLOGY CO., LTD TEL: +86-755-83304518 / 83308451/81353151 FAX: +86-755-83302824 Address: NO.813,212BLD,Tairan Tech Park, Futian District Shenzhen China

More information

+3.3V-Powered, EIA/TIA-562 Dual Transceiver with Receivers Active in Shutdown

+3.3V-Powered, EIA/TIA-562 Dual Transceiver with Receivers Active in Shutdown 19-0198; Rev 0; 10/9 +.Powered, EIA/TIA-5 Dual Transceiver General Description The is a +.powered EIA/TIA-5 transceiver with two transmitters and two receivers. Because it implements the EIA/TIA-5 standard,

More information

Integrity Instruments

Integrity Instruments Integrity Instruments XP-A/I User Manual Integrity Instruments P.O. Box Order Phone 00-0-00 Pine River Minnesota Fax Phone -- USA Tech Phone --0 http://www.integrityusa.com XP-A ISOLATED XP-I RS- to RS-

More information

Summary of Well Known Interface Standards

Summary of Well Known Interface Standards Summary of Well Known Interface Standards Forward Designing an interface between systems is not a simple or straight-forward task. s that must be taken into account include: data rate, data format, cable

More information

Introduction. Protocol Definitions. The RS-485 Standard. APPLICATION NOTE 3884 How Far and How Fast Can You Go with RS-485?

Introduction. Protocol Definitions. The RS-485 Standard. APPLICATION NOTE 3884 How Far and How Fast Can You Go with RS-485? Maxim > App Notes > Interface Circuits Keywords: RS485, RS422, RS-485, RS-422, Interface, Protocol, Line Drivers, Differential Line Drivers Jul 25, 2006 APPLICATION NOTE 3884 How Far and How Fast Can You

More information

UNICOM 2500 UNICOM Installation Operation Programming. Universal Communication Converter

UNICOM 2500 UNICOM Installation Operation Programming. Universal Communication Converter User Manual UNICOM 2500 Installation Operation Programming Universal Communication Converter UNICOM 2500 Electro Industries/GaugeTech 1800 Shames Drive Westbury, New York 11590 Tel 516.334.0870 Fax 516.338.4741

More information

Appendix C RS-485 Network

Appendix C RS-485 Network Appendix C RS-485 Network EIA RS-485 is the industry s most widely used bidirectional, balanced transmission line standard. It is specifically developed for industrial multi-drop systems that should be

More information

U1601 ENERGY CONTROL SYSTEM

U1601 ENERGY CONTROL SYSTEM 3-348-844-03 4/8.05 64 processing channels physical inputs or LON meter outputs can be assigned for the calculation of energy, power and costs Energy Control Language for the programming of analysis, monitoring

More information

TD_485 Transceiver Modules Application Guide 2017

TD_485 Transceiver Modules Application Guide 2017 TD_485 Transceiver Modules Application Guide 2017 1. RS485 basic knowledge... 2 1.1. RS485 BUS basic Characteristics... 2 1.2. RS485 Transmission Distance... 2 1.3. RS485 bus connection and termination

More information

CFO900 Series. User Manual. Audio/Data/Current Loop Mux/Demux CSX111, CSX123 & CSX222. CFO CSX series user manual, , rev003

CFO900 Series. User Manual. Audio/Data/Current Loop Mux/Demux CSX111, CSX123 & CSX222. CFO CSX series user manual, , rev003 CFO900 Series User Manual Audio/Data/Current Loop Mux/Demux CSX, CSX23 & CSX222 CFO CSX series user manual, 59300048, rev003 Contents The CSX Series Multiplexer Introduction... Introduction... Frame installation...2

More information

CL4490 HARDWARE INTEGRATION GUIDE VERSION 1.0. FCC Notice.

CL4490 HARDWARE INTEGRATION GUIDE VERSION 1.0. FCC Notice. CL4490 HARDWARE INTEGRATION GUIDE VERSION 1.0 wireless.support@lairdtech.com FCC Notice WARNING: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

More information

CL4790 HARDWARE INTEGRATION GUIDE VERSION 3.0. Americas: Europe: Hong Kong:

CL4790 HARDWARE INTEGRATION GUIDE VERSION 3.0. Americas: Europe: Hong Kong: CL4790 HARDWARE INTEGRATION GUIDE VERSION 3.0 Americas: +1-800-492-2320 FCC Notice WARNING: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)

More information

Dual Protocol Transceivers Ease the Design of Industrial Interfaces

Dual Protocol Transceivers Ease the Design of Industrial Interfaces Dual Protocol Transceivers Ease the Design of Industrial Interfaces Introduction The trend in industrial PC designs towards smaller form factors and more communication versatility is driving the development

More information

9600 bps, Dual Modem 170 Card Private Wire Only

9600 bps, Dual Modem 170 Card Private Wire Only 896 9600 bps, Dual Modem 170 Card Private Wire Only Users Guide 280 Interstate 80 West Exit 1 / PO Box 1330, Verdi, NV 89439 Phone: 775-345-8000 Fax: 775-345-8010 E-mail: traffic@sgdi.net TABLE OF CONTENTS

More information

2070-6B Manual B Manual. Dual 9600 baud Modem For The 2070 Controller. GDI B Manual. Rev B

2070-6B Manual B Manual. Dual 9600 baud Modem For The 2070 Controller. GDI B Manual. Rev B 2070-6B Manual 1 2070-6B Manual Dual 9600 baud Modem For The 2070 Controller GDI 2070-6B Manual Rev B This Manual covers Modems with the Serial numbers D700000 and up. 2070-6B Manual 2 GDI 2070-6B Manual

More information

USER'S MANUAL. Model : K

USER'S MANUAL. Model : K USER'S MANUAL Model : 2000-64K TM GINA MODEL 2000-64K Overview GINA Model 2000-64K is a stand-alone, high frequency data transceiver using spread spectrum technology. GINA 2000-64K capabilities include

More information

NETWORK ANALYZERS Analyzers

NETWORK ANALYZERS Analyzers CONTENTS PRODUCTS RANGE NA.03 NETWORK ANALYZER - LCC NETWORK ANALYZER - LCA NETWORK ANALYZER - LDA NETWORK ANALYZER - LAB96 NETWORK ANALYZER - LABM NA.04 NA.06 NA.09 NA.10 NA.13 NETWORK ANALYZER - LCCM

More information

SP339E RS-232/RS-485/RS-422 TRANSCEIVER WITH INTERNAL TERMINATION

SP339E RS-232/RS-485/RS-422 TRANSCEIVER WITH INTERNAL TERMINATION DECEMBER 2013 REV. 1.0.4 GENERAL DESCRIPTION The SP339 is an advanced multiprotocol transceiver supporting RS-232, RS-485, and RS-422 serial standards in a 40 pin QFN package. Integrated cable termination

More information

Installation and Operation Manual HS-R. 4-Channel Low Speed Data Module with V.110 Rate Adaptation MEGAPLEX-2100 MODULE

Installation and Operation Manual HS-R. 4-Channel Low Speed Data Module with V.110 Rate Adaptation MEGAPLEX-2100 MODULE Installation and Operation Manual HS-R 4-Channel Low Speed Data Module with V110 Rate Adaptation MEGAPLEX-2100 MODULE MEGAPLEX-2100 MODULE HS-R 4-Channel Low Speed Data Module with V110 Rate Adaptation

More information

CONTROL MICROSYSTEMS SCADAWave Radio Transceiver. Hardware Manual

CONTROL MICROSYSTEMS SCADAWave Radio Transceiver. Hardware Manual 5908 SCADAWave Radio Transceiver Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9 Technical

More information

Atrie WireSpan 600/610 MODEM User's Manual

Atrie WireSpan 600/610 MODEM User's Manual Atrie WireSpan 600/610 MODEM User's Manual WireSpan 600 / 610 Fractional E1 Access Unit Installation and Operation manual CONTENTS CHAPTER 1 Interduction.. 1-1 CHAPTER 2 Installation and Setup.. 2-1 CHAPTER

More information

125Mbps~155Mbps Multimode 850nm, SFP Transceiver

125Mbps~155Mbps Multimode 850nm, SFP Transceiver AXFE-5814 125Mbps~155Mbps Multimode 850nm, SFP Transceiver Product Overview Features The AXFE-5814 family of Small Form Factor Pluggable (SFP) transceiver module is specifically designed for the high performance

More information

Modbus communication module for TCX2: AEX-MOD

Modbus communication module for TCX2: AEX-MOD Modbus communication module for TCX2: Communication Specification TCX2 is factory installed in TCX2 series controllers with -MOD suffix, and is also available separately upon request for customer installation

More information

RM24100D. Introduction. Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

RM24100D. Introduction. Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1. RM24100D 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE 802.15.4 compliant) Operating Manual English 1.09 Introduction The RM24100D radio modem acts as a wireless serial cable replacement and

More information

AccessCON-N64 INTERFACE CONVERTER E1/FRACTIONAL E1 TO N64 INSTALLATION AND OPERATION MANUAL. Version 1

AccessCON-N64 INTERFACE CONVERTER E1/FRACTIONAL E1 TO N64 INSTALLATION AND OPERATION MANUAL. Version 1 INTERFACE CONVERTER E1/FRACTIONAL E1 TO N64 INSTALLATION AND OPERATION MANUAL Version 1 Copyright 2005 by S-Access GmbH. The contents of this publication may not be reproduced in any part or as a whole,

More information

XR3160E RS-232/RS-485/RS-422 TRANSCEIVER WITH 15KV ESD PROTECTION

XR3160E RS-232/RS-485/RS-422 TRANSCEIVER WITH 15KV ESD PROTECTION Sept 2013 Rev. 1.0.0 GENERAL DESCRIPTION The XR3160 is an advanced multiprotocol transceiver supporting RS-232, RS-485, and RS-422 serial standards. Full operation requires only four external charge pump

More information

I-2533CS series User Manual

I-2533CS series User Manual I-2533CS series User Manual Version 1.0.0, Sep. 2013 Service and usage information for I 2533CS / I 2533CS 60 / I 2533CS A / I 2533CS B I-2533CS series CAN to Single Mode Fiber Bridge User Manual (version

More information

INDUSTRIAL+COMMERCIAL ZMG400AR/CR, ZFG400AR/CR TECHNICAL DATA. IEC-specific data. Current. Measurement Accuracy. Measurement Behaviour.

INDUSTRIAL+COMMERCIAL ZMG400AR/CR, ZFG400AR/CR TECHNICAL DATA. IEC-specific data. Current. Measurement Accuracy. Measurement Behaviour. Electricity Meters IEC/MID INDUSTRIAL+COMMERCIAL Landis+Gyr Dialog ZMG400AR/CR, ZFG400AR/CR TECHNICAL DATA IEC-specific data Current Nominal Current I n 1 A, 5 A, 5 1 A Maximal Current I max metrological

More information

+3.3V, Multiprotocol, 3 Tx/3 Rx, Software- Selectable Clock/Data Transceiver

+3.3V, Multiprotocol, 3 Tx/3 Rx, Software- Selectable Clock/Data Transceiver 19-333; Rev ; 4/ +3.3V, Multiprotocol, 3 Tx/3 Rx, Software- General Description The is a three-driver/three-receiver multiprotocol transceiver that operates from a +3.3V single supply. The, along with

More information

Home Automation, Inc. Omnistat2. RC-1000 and RC-2000 Communicating Thermostat. Serial Protocol Description

Home Automation, Inc. Omnistat2. RC-1000 and RC-2000 Communicating Thermostat. Serial Protocol Description Home Automation, Inc. Omnistat2 RC-1000 and RC-2000 Communicating Thermostat Serial Protocol Description This document contains the intellectual property of Home Automation, Inc. (HAI). HAI authorizes

More information

Serial data converters

Serial data converters Serial data converters ILPH range Content Uses... 5/30 Selection t able... 5/31 Ordering d etails... 5/32 Technical data... 5/32 5 5/29 Serial data converters ILPH range Uses In the field of industrial

More information

RS-232 to Current Loop Converters

RS-232 to Current Loop Converters CL1060/1090xxx 703 5856 RS-232 to Current Loop Converters DB25F to DB25M Product Code CL1060A-M DB25M to DB25F Product Code CL1060A-F DB25M to Terminal Block Product Code CL1090A-M DB25F to Terminal Block

More information

Technical description MT24. User manual WARNING GENERAL INSTRUCTIONS GENERAL DESCRIPTION

Technical description MT24. User manual WARNING GENERAL INSTRUCTIONS GENERAL DESCRIPTION WARIG The equipment makes a compact set of the switchboard. Just this set is safe from the point of electrical shock. Therefore do not use other power supplies or circuits than mentioned in this direction

More information

+3.3V Multiprotocol 3Tx/3Rx Software-Selectable Control Transceivers

+3.3V Multiprotocol 3Tx/3Rx Software-Selectable Control Transceivers 19-173; Rev 1; 8/1 +3.3V Multiprotocol 3Tx/3Rx General Description The are three-driver/three-receiver multiprotocol transceivers that operate from a single +3.3V supply. The, along with the MAX317 and

More information

DMP Electronics Inc Robotic Division

DMP Electronics Inc Robotic Division DMP Electronics Inc Robotic Division Jul 2009 Agenda DMP SoC Family RB-100 Overview Hardware Introduction Accessory Support List Application Q & A DMP s ssoc Family Jul. 1998 Feb. 2007 386 40MHz 486 300MHz

More information

DTR-xxx-3.3-SM-T. 3.3 Volt Single Mode Transceivers (1x9 pin-out) ! Single +3.3 V supply & LV-PECL data interface. ! Eye Safe (Class I Laser Safety)

DTR-xxx-3.3-SM-T. 3.3 Volt Single Mode Transceivers (1x9 pin-out) ! Single +3.3 V supply & LV-PECL data interface. ! Eye Safe (Class I Laser Safety) OCP Description DTR-xxx-3.3-SM-T 3.3 Volt Single Mode Transceivers (1x9 pin-out) The DTR-xxx-3.3-SM-T fiber optic transceivers are the 3.3V power supply versions of our standard DTR-xxx-SM fiber optic

More information

Instruction Manual MT-945SL Four Channel Video Transmitter With Two Bi-Directional Data Channels

Instruction Manual MT-945SL Four Channel Video Transmitter With Two Bi-Directional Data Channels Instruction Manual MT-945SL Four Channel Video Transmitter With Two Bi-Directional Data Channels Copyright 2006, American Fibertek, Inc. 0307JD Table of Contents Functional Description... 3 Installation...

More information

GCAN-208-1/-2. Fiber-CAN converter. User Manual

GCAN-208-1/-2. Fiber-CAN converter. User Manual GCAN-208-1/-2 Fiber-CAN converter User Manual Contents 1 Introduction... 3 1.1 Overview... 3 1.2 Properties at a glance... 3 2 Interface specification... 4 3 Connection and use... 6 3.1 CAN-Bus configuration...

More information

285E Series DIGITAL FIBER OPTIC AUDIO/DATA TRANSPORT SYSTEM

285E Series DIGITAL FIBER OPTIC AUDIO/DATA TRANSPORT SYSTEM 285E Series DIGITAL FIBER OPTIC AUDIO/DATA TRANSPORT SYSTEM BCI reserves the right to make changes to the products described herein without prior notice or consent. No liability is assumed as a result

More information

Lecture 5 Transmission. Physical and Datalink Layers: 3 Lectures

Lecture 5 Transmission. Physical and Datalink Layers: 3 Lectures Lecture 5 Transmission Peter Steenkiste School of Computer Science Department of Electrical and Computer Engineering Carnegie Mellon University 15-441 Networking, Spring 2004 http://www.cs.cmu.edu/~prs/15-441

More information

Applications. Operating Modes. Description. Part Number Description Package. Many to one. One to one Broadcast One to many

Applications. Operating Modes. Description. Part Number Description Package. Many to one. One to one Broadcast One to many RXQ2 - XXX GFSK MULTICHANNEL RADIO TRANSCEIVER Intelligent modem Transceiver Data Rates to 100 kbps Selectable Narrowband Channels Crystal controlled design Supply Voltage 3.3V Serial Data Interface with

More information

King Fahd University of Petroleum & Minerals Computer Engineering Dept

King Fahd University of Petroleum & Minerals Computer Engineering Dept King Fahd University of Petroleum & Minerals Computer Engineering Dept COE 342 Data and Computer Communications Term 021 Dr. Ashraf S. Hasan Mahmoud Rm 22-144 Ext. 1724 Email: ashraf@ccse.kfupm.edu.sa

More information

MD-45 AC MD-45 LV/HV INSTALLATION MANUAL

MD-45 AC MD-45 LV/HV INSTALLATION MANUAL MD-45 AC MD-45 LV/HV INSTALLATI MANUAL 6157-2213 Westermo Teleindustri A 2003 REV.A Galvanic Isolation Transient Protection alanced Transmission CE Approved Converter RS-232 RS-422/485 www.westermo.us

More information