INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MA-19. Korthållsmodem Short Haul Modem Kurzstreckenmodem

Size: px
Start display at page:

Download "INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MA-19. Korthållsmodem Short Haul Modem Kurzstreckenmodem"

Transcription

1 INSTALLATISANVISNING INSTALLATI MANUAL INSTALLATIS ANLEITUNG Galvanic Isolation 0-00 Transient Protection Balanced Transmission CE Approved Westermo Teleindustri AB REV. A Korthållsmodem Short Haul Modem Kurzstreckenmodem

2 Specifications Transmission Asynchronous Full/half duplex or simplex Interface EIA RS--C/CCITTV., V. -pin D-sub, female DCE Interface 0 ma tri-state balanced current loop -position detachable screw-terminal mounted on the rack s back board Transmission rate 0-, kbit/s Indicators Power, TD, RD,, DCD Isolation Complete galvanic insulation with opto-coupler (data) and transformer (supply) Isolation voltage 00 V Power supply External through PS-0 mounted in rack (RV-0) ±0 V DC ±0% Power consumption +0V 0 ma, -0V 0 ma Temperature range -0 C Humidity 0-% RH, non-condensing Dimension 00x00 mm Weight 0. kg Mounting In rack, takes one card-slot in RV

3 Switch settings The can through different switch settings be adapted to a variety of operating conditions. The switches are located on the circuit board and have the following functions: - - F/F Selection of signal activating transmitter (carrier) Selection of signal controlling CTS Fuse 00mA Fast F F Transmitter (carrier) activated by CTS controlled by Always active AUX Always high SRS DCD RFR DTR Factory settings DTR and AUX DTR and SRS DTR and RFR DTR and 0-00

4 Connections Line connection (-Position screw-terminal) Direction No. Description Direction ) Pin CCITT V. Description no. Circuit no. Transmitter R+ Transmitter R- Receiver T+ Receiver T- Shield Terminal connection (DCE) (RS--C/V./V., -Position D-sub, female) I 0 TD/Transmitted Data O 0 RD/Received Data I 0 /Request To Send O 0 CTS/Clear To Send O 0 DSR/Data Set Ready 0 SG/Signal Ground O 0 DCD/Data Carrier Detect I AUX/Auxiliary I 0 SRS/Secondary Request to Send I 0 0/ DTR/Data Terminal Ready I RFR/Ready For Receiving I=Input O=Output on Section of rack RV-0 with one mounted. Terminal connection to a -position D-sub (female) connector on. Line connection to a -position detachable screw-terminal, which is mounted on the male connector located at the rear of RV

5 Line connection Twisted pairs ±0 ma Current Loop e.g. MA- Receiver R+ T+ Transmitter R- T- Transmitter T+ R+ Receiver Shield ) T- R- ) If shielded cable is used, connect the shield only at one end to avoid ground currents. Transmission range (interface ) Cable Transmission rate bit/s pf/m 0.mm m m m m 00 00m m 00 00m 0-00

6 Hints The has the same line interface as many of Westermo s systems MA-, MA-, MA-, MA-, MM-, MM-, LA-0, LD-0 and LD-0 are hence compatible. The RS- interface on the is configured as DCE (Data Communication Equipment). Most printers, PC s and terminals are set as DTE (Data Terminal Equipment). Some recommendation of cable configurations are given below. If any problems do occur on set up of the, the LED s will be helpful. - PWR: The unit has power. - RD: Data received on line interface. - TD: Data received on RS- interface. - DCD: Carrier indication, must be on for transmission. - : Indicates the carrier control status. A good way to check the MA- is to carry out a loop back test. Connect T+ to R+ and T- to R-. Connect the RS- port to a terminal. When keys are pressed on the terminal you should receive the echo on screen. The TD & RD lights will both flicker simultaneously as you press the keys. DTE DCE pol. PC

7 OWN COMMENTS 0-00

8 Block diagram RS--C/V. LINE ) DTR AUX X 0 +V & +V SRS RFR CTS DCD RD RD DCD R+ () R- () DSR TD SG +V 0V TD EN +V 0V T+ () T- () () Shield 0V X 0V POWER SUPPLY -...V +...V 0 00mA 00mA STAB +V 0V -V +V -V 0V -V Westermo Teleindustri AB have distributors in several countries, contact us for further information. Westermo Teleindustri AB S-0 0 Stora Sundby, Sweden Phone + 00 Fax info@westermo.se Westermo Web site: Westermo Data Communications Ltd Solent Business Centre Millbrook Road West Millbrook, Southampton SO 0HW Phone: +(0)0-0 Fax.:+(0)0 0 sales@westermo.co.uk Subsidiaries Westermo Data Communications GmbH Bruchsaler Straße, Waghäusel Tel.: +(0)-00-0 Fax.:+(0) westermo.germany@t-online.de TunaTryck AB, Eskilstuna, Sweden

INSTALLATIONSANVISNING MD-21 AC INSTALLATION MANUAL REV. A MD-21DC INSTALLATIONS ANLEITUNG

INSTALLATIONSANVISNING MD-21 AC INSTALLATION MANUAL REV. A MD-21DC INSTALLATIONS ANLEITUNG MD- AC MD-DC INSTALLATISANVISNING INSTALLATI MANUAL INSTALLATIS ANLEITUNG Galavanic Isolation -00 Transient Protection CE Approved Westermo Teleindustri AB REV. A Strömslingeomvandlare Current loop converter

More information

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MA-12 AC MA-12 DC. Korthållsmodem Short haul modem Kurzstreckenmodem

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MA-12 AC MA-12 DC. Korthållsmodem Short haul modem Kurzstreckenmodem MA- AC MA- DC INSTALLATISANVISNING INSTALLATI MANUAL INSTALLATIS ANLEITUNG Galavanic Isolation Transient Protection 0-00 Balanced Transmission CE Approved Westermo Teleindustri AB REV. A Korthållsmodem

More information

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MD-42 AC MD-42 DC

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MD-42 AC MD-42 DC MD- AC MD- DC INSTALLATISANVISNING INSTALLATI MANUAL INSTALLATIS ANLEITUNG Galvanic Isolation 65-00 Transient Protection Balanced Transmission CE Approved Westermo Teleindustri AB 999 Rev. B Omvandlare

More information

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG LD-34 AC LD-34 DC

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG LD-34 AC LD-34 DC LD-34 AC LD-34 DC INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG Galvanic Isolation 6603-2001 CE Approved Westermo Teleindustri AB 1999 REV. A 4 kanalig switch - /V.24 4 channel switch

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MD-44 AC MD-44 DC

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MD-44 AC MD-44 DC MD-44 C MD-44 DC INSTLLTISNVISNING INSTLLTI MNUL INSTLLTIS NLEITUNG Galvanic Isolation 6155-2002 Transient Protection alanced Transmission CE pproved Westermo Teleindustri 1999 REV. Omvandlare RS-22 RS-422/485

More information

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MANUEL D INSTALLATION MD-45 AC MD-45 LV/HV

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MANUEL D INSTALLATION MD-45 AC MD-45 LV/HV MD-45 AC MD-45 LV/HV INSTALLATISANVISNING INSTALLATI MANUAL INSTALLATIS ANLEITUNG MANUEL D INSTALLATI 6157-2003 Westermo Teleindustri A 2003 REV.A Galvanic Isolation Transient Protection alanced Transmission

More information

INSTALLATIONSANVISNING INSTALLATION MANUAL MA-44/MA-44DC OMVANDLARE RS RS-422/485 CONVERTER RS RS-422/485. Balanced Transmission

INSTALLATIONSANVISNING INSTALLATION MANUAL MA-44/MA-44DC OMVANDLARE RS RS-422/485 CONVERTER RS RS-422/485. Balanced Transmission NSTALLATNSANVSNNG NSTALLATN MANUAL MA-/MA-DC MVANDLARE RS- -- RS-/8 CNVERTER RS- -- RS-/8 Galvanic nsulation Transient Protection alanced Transmission CE Approved SPECFKATNER SPECFCATNS ANSLUTNNGAR CNNECTNS

More information

MD-45 AC MD-45 LV/HV INSTALLATION MANUAL

MD-45 AC MD-45 LV/HV INSTALLATION MANUAL MD-45 AC MD-45 LV/HV INSTALLATI MANUAL 6157-2213 Westermo Teleindustri A 2003 REV.A Galvanic Isolation Transient Protection alanced Transmission CE Approved Converter RS-232 RS-422/485 www.westermo.us

More information

User Guide. Westermo Teleindustri AB 2004 REV.A MDW Converter RS-232 RS-422/485.

User Guide. Westermo Teleindustri AB 2004 REV.A MDW Converter RS-232 RS-422/485. User Guide MDW-45 6617-2201 Westermo Teleindustri AB 2004 REV.A Converter RS-422/485 www.westermo.com Safety! Before using this unit: Read this manual completely and gather all information on the unit.

More information

PRODUCT INFORMATION B&B ELECTRONICS. Port-Powered RS-232 Fiber Optic Modem with Handshake Support. Model 9PFLST. Description. RS-232 Connections

PRODUCT INFORMATION B&B ELECTRONICS. Port-Powered RS-232 Fiber Optic Modem with Handshake Support. Model 9PFLST. Description. RS-232 Connections -01-1/ 00 by B&B Electronics. All rights reserved. Model Port-Powered RS- Fiber Optic Modem with Handshake Support Description The allows any two pieces of RS- asynchronous serial equipment to communicate

More information

FOM-5A, 6A Asynchronous Fiber Optic Modems

FOM-5A, 6A Asynchronous Fiber Optic Modems ORDERING FOM-5A/*/+ Asynchronous Sub-miniature Fiber Optic Modem FOM-6A/*/+/# Asynchronous Miniature Fiber Optic Modem * Specify: F for female 25-pin connector M for male 25-pin connector + Specify: ST

More information

ADA-1028L. User manual ADA-1028L. RS232 to Current Loop 2-wire CLO Converter. 1 io_ada-1028l_v.1.10_en. Copyright CEL-MAR sp.j.

ADA-1028L. User manual ADA-1028L. RS232 to Current Loop 2-wire CLO Converter. 1 io_ada-1028l_v.1.10_en. Copyright CEL-MAR sp.j. User manual ADA-1028L to Current Loop 2-wire Converter Copyright 2001-2017 CEL-MAR sp.j. 1 io_ada-1028l_v.1.10_en Contents 1. GENERAL INFORMATION... 3 1.1. WARRANTED INFORMATION... 3 1.2. GENERAL CONDITIONS

More information

MDW-45 Converter RS RS-422/485

MDW-45 Converter RS RS-422/485 www.westermo.com MDW-45 Converter RS-232 - RS-422/485 2 6617-2203 General information Legal information The contents of this document are provided as is. Except as required by applicable law, no warranties

More information

Concept of Serial Communication

Concept of Serial Communication Concept of Serial Communication Agenda Serial v.s. Parallel Simplex, Half Duplex, Full Duplex Communication RS-485 Advantage over RS-232 Serial v.s. Parallel Application: How to Measure the temperature

More information

ADA User manual ADA RS-232 to RS-485 / RS-422 Converter

ADA User manual ADA RS-232 to RS-485 / RS-422 Converter User manual RS- to RS- / RS- Converter Copyright 001-01 CEL-MAR sp.j. 1 io_ada-100_v._en Contents 1. GENERAL INFORMATION... 1.1. WARRANTED INFORMATION... 1.. GENERAL CONDITIONS FOR SAFE USE... 1.. CE LABEL...

More information

Universal Converter Covers All the Bases- RS-232 to 4-wire RS-422, 2-wire or 4-wire RS-485

Universal Converter Covers All the Bases- RS-232 to 4-wire RS-422, 2-wire or 4-wire RS-485 4WSD9R0712-1/4 Model 4WSD9R Universal Converter Covers All the Bases- RS-232 to 4-wire RS-422, 2-wire or 4-wire RS-485 The 4WSD9R Universal Converter is a port-powered or externally powered two-channel

More information

Interface converter G kbit/sec

Interface converter G kbit/sec converter User s Guide 12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212345678901 Interface converter G.703.1 64 kbit/sec Features Maximum line attenuation

More information

USER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 2017A RS-232 to 20ma Current Loop Converter Part# 07M2017A-A Doc# 073021UA Revised 10/15/93 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com 1.0 WARRANTY

More information

This FAQ covers Single Direction use of current loop with transmitting devices.

This FAQ covers Single Direction use of current loop with transmitting devices. PAGE 1 OF 5 This FAQ covers Single Direction use of current loop with transmitting devices. Q: How do I connect the Current Loop Converter to my Current Loop device? A: This Current Loop interface has

More information

User Guide Westermo Teleindustri AB TR-36. Tele and leased line modem for RV rack system.

User Guide Westermo Teleindustri AB TR-36. Tele and leased line modem for RV rack system. User Guide 6614-2202 TR-36 Westermo Teleindustri AB 4 3 2 1 4 3 2 1 Tele and leased line modem for RV-07 19 rack system www.westermo.com Legal information The contents of this document are provided as

More information

This FAQ covers the common questions from technicians installing these converters.

This FAQ covers the common questions from technicians installing these converters. PAGE 1 OF 6 This FAQ covers the common questions from technicians installing these converters. Q: How do I connect the Current Loop Converter to my Current Loop device? A: This Current Loop interface has

More information

Universal RS232/CMOS to RS422/RS485 Converter

Universal RS232/CMOS to RS422/RS485 Converter TOSHIBA INTERNATIONAL CORPORATION Universal RS232/CMOS to RS422/RS485 Converter Rev No.: 2 Page No.: 1 RS232/CMOS to RS422/RS485 Converter converts RS232/CMOS lines to balanced RS422 or RS485 signals.

More information

INDUSTRIAL OPTO-ISOLATED RS-232 REPEATER

INDUSTRIAL OPTO-ISOLATED RS-232 REPEATER QUICK START GUIDE ICD201A INDUSTRIAL OPTO-ISOLATED RS-232 REPEATER 24/7 TECHNICAL SUPPORT AT 877.877.2269 OR VISIT BLACKBOX.COM STEP 1 - What s Included ICD201A Industrial Opto-Isolated RS-232 to RS-422/485

More information

Miniature Synchronous Multipoint Modems

Miniature Synchronous Multipoint Modems ME1735A-F JULY 2003 Miniature Synchronous Multipoint Modems CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support 24 hours

More information

A50/A51/A60. June 2008 (4th Edition) All Rights Reserved

A50/A51/A60. June 2008 (4th Edition) All Rights Reserved A50/A51/A60 June 2008 (4th Edition) All Rights Reserved Part I - A50/A51 RS-232 to RS-422/RS-485 Converter A50/A51 RS-232 to RS-422/RS-485 Bidirectional Converter Part II - A60 RS-232 Surge Protection

More information

RS-232 / 20mA Interface Converter ELO E00Q. Operation manual

RS-232 / 20mA Interface Converter ELO E00Q. Operation manual RS-232 / 20mA Interface Converter ELO E00Q Operation manual 2 ELOE00QZKE001 1.0 Introduction 4 1.1 Use of the converter 4 2.0 Operation principles 4 3.0 Installation 4 3.1 Converter connection to RS-232

More information

Electronics / Water analogy. Resistor. Inductance. Capacitor. Water Electronics Energy - Energy Pressure - Voltage Flow - Current Volume - Charge

Electronics / Water analogy. Resistor. Inductance. Capacitor. Water Electronics Energy - Energy Pressure - Voltage Flow - Current Volume - Charge Electronics / Water analogy Water Electronics Energy - Energy Pressure - Voltage Flow - Current Volume - Charge Resistor U = R * I 1 Capacitor U 1 i dt C U L di dt Inductance Turbine Flywheel Diode Transistor

More information

Interface: Serial EIA RS-232D/CCITT V.24, DCE; RTS/CTS delay 0,8 or 64 ms (user-selectable).

Interface: Serial EIA RS-232D/CCITT V.24, DCE; RTS/CTS delay 0,8 or 64 ms (user-selectable). BLACK BOX PWR RTS TD-1 RD-1 TD-2 DCD RD-2 TEST DIG ANA REM LDM-MR 19.2 REM ANA DIG AGC 2/4 WIRE ABLE / ABLE SWITCHES 2 W 4 W 1 2 3 4 CARRIER LEVEL 0 dbm -3 dbm -6 dbm -9 dbm PIN 21 (RLB) RPF PIN 18 AN.

More information

M9606. FSK Modem. 5C Communications Inc.

M9606. FSK Modem. 5C Communications Inc. FSK Modem Application modem is a voice-frequency telegraphy unit (VFT unit) which operates according to the principle of binary frequency shift keying. It is designed especially for Power Industrial applications.

More information

Modem 9600 baud 500FSD11 EDS500 series - FSK modems

Modem 9600 baud 500FSD11 EDS500 series - FSK modems Data sheet Modem 9600 baud 500FSD11 EDS500 series - FSK modems Voice frequency telegraphy device (VFT) Transparent up to 9600 baud Can be connected to 23WT24 DIN rail mounted 24...60 V DC supply voltage

More information

DigiPoints Volume 1. Student Workbook. Module 2 Modem Overview

DigiPoints Volume 1. Student Workbook. Module 2 Modem Overview Modem Overview Page 2.1 DigiPoints Volume 1 Module 2 Modem Overview Summary One of the potential advantages the cable telecommunications industry has is the ability to carry data signals at speeds significantly

More information

APPLICATION BULLETIN. SERIAL BACKGROUNDER (Serial 101) AB23-1. ICS ICS ELECTRONICS division of Systems West Inc. INTRODUCTION CHAPTER 2 - DATA FORMAT

APPLICATION BULLETIN. SERIAL BACKGROUNDER (Serial 101) AB23-1. ICS ICS ELECTRONICS division of Systems West Inc. INTRODUCTION CHAPTER 2 - DATA FORMAT ICS ICS ELECTRONICS division of Systems West Inc. AB- APPLICATION BULLETIN SERIAL BACKGROUNDER (Serial 0) INTRODUCTION Serial data communication is the most common means of transmitting data from one point

More information

Modem 1200 baud 500FSD10 EDS500 series - FSK modems

Modem 1200 baud 500FSD10 EDS500 series - FSK modems Manual Modem 1200 baud 500FSD10 EDS500 series - FSK modems Application, characteristics and technical data have to be taken from the hardware data sheet: 500FSD10 Data sheet 1KGT150982 Operation The 500FSD10

More information

Installation and Operation Manual HS-R. 4-Channel Low Speed Data Module with V.110 Rate Adaptation MEGAPLEX-2100 MODULE

Installation and Operation Manual HS-R. 4-Channel Low Speed Data Module with V.110 Rate Adaptation MEGAPLEX-2100 MODULE Installation and Operation Manual HS-R 4-Channel Low Speed Data Module with V110 Rate Adaptation MEGAPLEX-2100 MODULE MEGAPLEX-2100 MODULE HS-R 4-Channel Low Speed Data Module with V110 Rate Adaptation

More information

Intermittent Vibration 0.075

Intermittent Vibration 0.075 FEATURES DESCRIPTION PLC-COM-CM1 Series Multi Drop Configuration of up to 32 Units Baud Rates Range from 300 to 38,400 bps 1:1/1:N/N:M (RS-422) Communication is Supported Full-Duplex (RS-422) and Half-Duplex

More information

Cable and Port Specifications

Cable and Port Specifications APPENDIX D This appendix includes the following information: Cables and Adapters Provided, page D-1 Console Port, page D-2 COM1 Port, page D-3 MGMT 10/100 Ethernet Port, page D-5 SFP Transceiver Specifications,

More information

EIA-232 Information. DTE Signal Direction. DCE Signal Direction. Signal EIA

EIA-232 Information. DTE Signal Direction. DCE Signal Direction. Signal EIA EIA EIA-232 Information This is one of the most misunderstood areas of RS-232. DTE stands for Data Terminal Equipment, and DCE stands for Data Circuit-terminating Equipment or Data Communications Equipment.

More information

MODEL: DLS. Telemetering System

MODEL: DLS. Telemetering System POW RUN SA SA RT RU MODEL: DLS Telemetering System TELEMETERING UNIT Functions & Features Interfacing remote I/O devices with a modem for a telemetering system Process I/O (.0) [] POWER INPUT AC Power

More information

Telemetrie-Messtechnik Schnorrenberg

Telemetrie-Messtechnik Schnorrenberg Telemetrie-Messtechnik Schnorrenberg CT16-Wheel User manual TMS Telemetrie-Messtechnik Schnorrenberg Dipl.-Ing. Werner Schnorrenberg Habichtweg 30, D-51429 Bergisch Gladbach, Tel: 02204-9815-52, Fax: 02204-9815-53,

More information

ZCS485 User s Manual. Version ZYPEX, Inc.

ZCS485 User s Manual. Version ZYPEX, Inc. ZCS485 User s Manual Version 2.2 2004 ZYPEX, Inc. Table of Contents Product Description 1 ZCS485 Configuration & Setup 2 4-wire Operation 2 2-wire Operation 2 Dual Port Operation 2 Carrier Detect 2 Transmitter

More information

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V

More information

Voice-Frequency Telegraph Modem HY101-SWT

Voice-Frequency Telegraph Modem HY101-SWT Voice-Frequency Telegraph Modem HY101-SWT Revision: August 2014 V 1.6 08/14 1 HYTEC Gerätebau GmbH 2007 / HYTEC Gerätebau GmbH All rights reserved No part of this document may be reproduced or used except

More information

CTP16-Rotate. KMT - Kraus Messtechnik GmbH

CTP16-Rotate. KMT - Kraus Messtechnik GmbH KMT - Kraus Messtechnik GmbH Gewerbering 9, D-83624 Otterfing, Germany, 08024-48737, Fax. 08024-5532 Home Page http://www.kmt-telemetry.com, Email: info@kmt-telemetry.com CTP16-Rotate 16 channel telemetry

More information

User Manual CTP4/8/16

User Manual CTP4/8/16 KMT - Kraus Messtechnik GmbH Gewerbering 9, D-83624 Otterfing, Germany, 08024-48737, Fax. 08024-5532 Home Page http://www.kmt-telemetry.com, Email: info@kmt-telemetry.com User Manual CTP4/8/16 4/8/16-channel

More information

User Guide. Westermo Teleindustri AB 2006 IDW ISDN Terminaladapter.

User Guide. Westermo Teleindustri AB 2006 IDW ISDN Terminaladapter. User Guide IDW-90 Westermo Teleindustri AB 2006 6620-2200 ISDN Terminaladapter www.westermo.com Legal information The contents of this document are provided as is. Except as required by applicable law,

More information

M-Bus Master MultiPort 250L Installation and User Guide

M-Bus Master MultiPort 250L Installation and User Guide Installation and User Guide Kamstrup A/S Industrivej 28, Stilling DK-8660 Skanderborg T: +45 89 93 10 00 info@kamstrup.com kamstrup.com Contents 1 Introduction 3 1.1 Design 3 2 Functionality 4 2.1 Overview

More information

MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE

MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE Distribué par : Contact : hvssystem@hvssystem.com Tél : 0326824929 Fax : 0326851908 Siège social : 2 rue René Laennec 51500 Taissy France www.hvssystem.com MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE

More information

USER'S MANUAL. Model : K

USER'S MANUAL. Model : K USER'S MANUAL Model : 2000-64K TM GINA MODEL 2000-64K Overview GINA Model 2000-64K is a stand-alone, high frequency data transceiver using spread spectrum technology. GINA 2000-64K capabilities include

More information

USER MANUAL MODEL Parallel to Serial/ Serial to Parallel Interface Converter

USER MANUAL MODEL Parallel to Serial/ Serial to Parallel Interface Converter USER MANUAL MODEL 2029 Parallel to Serial/ Serial to Parallel Interface Converter C E R T I F I E D An ISO-9001 Certified Company Part #07M2029-B, Rev. C Doc. #102011UB Revised 6/16/09 SALES OFFICE (301)

More information

Part Numbers. Fiber Driver - ST/DB25M FIBER DRIVER

Part Numbers. Fiber Driver - ST/DB25M FIBER DRIVER January 2010 MD940A-F MD940A-M Part Numbers - ST/DB25F MD940A-F - ST/DB25M MD940A-M FIBER DRIVER CUSTOMER Order toll-free in the U.S.: 877-877-BBOX (outside U.S. call 724-746-5500) SUPPORT FREE technical

More information

KiloStream Data Sheet

KiloStream Data Sheet KiloStream Data Sheet KiloStream speeds The choice of interfaces and speeds shown below enable a wide variety of equipment conforming to CCITT* standards to be connected. Speeds and interfaces Speed kbit/s

More information

Chapter 12: Digital Modulation and Modems

Chapter 12: Digital Modulation and Modems Chapter 12: Digital Modulation and Modems MULTIPLE CHOICE 1. FSK stands for: a. Full-Shift Keying c. Full-Signal Keying b. Frequency-Shift Keying d. none of the above 2. PSK stands for: a. Pulse-Signal

More information

ANALOG AND DIGITAL PHYSICAL INTERFACES

ANALOG AND DIGITAL PHYSICAL INTERFACES ANALOG AND DIGITAL PHYSICAL INTERFACES Habib Youssef, Ph.D youssef@ccse.kfupm.edu.sa Department of Computer Engineering King Fahd University of Petroleum and Minerals Dhahran, Saudi Arabia COMPUTER NETWORK

More information

9600 bps, Dual Modem 170 Card Private Wire Only

9600 bps, Dual Modem 170 Card Private Wire Only 896 9600 bps, Dual Modem 170 Card Private Wire Only Users Guide 280 Interstate 80 West Exit 1 / PO Box 1330, Verdi, NV 89439 Phone: 775-345-8000 Fax: 775-345-8010 E-mail: traffic@sgdi.net TABLE OF CONTENTS

More information

USER MANUAL. MODEL 3P-MF and 3P-MF9 DB-25 and DB-9 In-Line Power Supply Adapters SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 3P-MF and 3P-MF9 DB-25 and DB-9 In-Line Power Supply Adapters SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 3P-MF and 3P-MF9 DB-25 and DB-9 In-Line Power Supply Adapters An ISO-9001 CertiÞed Company Part# 07M3PMF9 Rev. C Doc# 056020U Revised 1/23/08 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT

More information

Lecture #3 RS232 & 485 protocols

Lecture #3 RS232 & 485 protocols SPRING 2015 Integrated Technical Education Cluster At AlAmeeria E-626-A Data Communication and Industrial Networks (DC-IN) Lecture #3 RS232 & 485 protocols Instructor: Dr. Ahmad El-Banna 1 Agenda What

More information

SPECIAL SPECIFICATION 1533 Drop/Insert Multiplexor/Demultiplexor

SPECIAL SPECIFICATION 1533 Drop/Insert Multiplexor/Demultiplexor 1993 Specifications CSJ 0177-11-131 SPECIAL SPECIFICATION 1533 Drop/Insert Multiplexor/Demultiplexor 1. Description. This Item shall govern for for the furnishing and installation of intelligent drop/insert

More information

Selection guide. Communication accessories. Communication accessory selection guide. Characteristics

Selection guide. Communication accessories. Communication accessory selection guide. Characteristics Communication accessories Selection guide There are 2 types of Sepam communication accessories: b communication interfaces, which are essential for connecting Sepam to the communication network b converters

More information

1995 Metric CSJ SPECIAL SPECIFICATION ITEM Drop/Insert Multiplexor/Demultiplexor

1995 Metric CSJ SPECIAL SPECIFICATION ITEM Drop/Insert Multiplexor/Demultiplexor 1995 Metric CSJ 3256-02-049 1.0 Description SPECIAL SPECIFICATION ITEM 6093 Drop/Insert Multiplexor/Demultiplexor This Item shall govern for the furnishing and installation of intelligent drop/insert multiplexor/demultiplexors

More information

Integrity Instruments

Integrity Instruments Integrity Instruments XP-A/I User Manual Integrity Instruments P.O. Box Order Phone 00-0-00 Pine River Minnesota Fax Phone -- USA Tech Phone --0 http://www.integrityusa.com XP-A ISOLATED XP-I RS- to RS-

More information

285E Series DIGITAL FIBER OPTIC AUDIO/DATA TRANSPORT SYSTEM

285E Series DIGITAL FIBER OPTIC AUDIO/DATA TRANSPORT SYSTEM 285E Series DIGITAL FIBER OPTIC AUDIO/DATA TRANSPORT SYSTEM BCI reserves the right to make changes to the products described herein without prior notice or consent. No liability is assumed as a result

More information

MGE TM Galaxy TM , 60 Hz kva

MGE TM Galaxy TM , 60 Hz kva Home Alarms Online Trend Statistics Rectifier Battery Inverter Bypass AC Bypass Output Set up Normal AC Q4S Load protected QBP QF 0 Hour 50 Min. 5 kva 00% 0% 00% 0 50% Load equipment 0 80% 50% Remote vision

More information

Non-Powered Interface Converters RS-232 to RS-530 RS-422 to V.35 RS-232 to RS-485 RS-232 to RS-422/RS-449

Non-Powered Interface Converters RS-232 to RS-530 RS-422 to V.35 RS-232 to RS-485 RS-232 to RS-422/RS-449 IC237A IC482A JUNE 1995 IC486A IC487A-F Non-Powered Interface Converters S-232 to S-530 S-422 to V.35 S-232 to S-485 S-232 to S-422/S-449 CUSTOME SUPPOT INFOMATION Order toll-free in the U.S. 24 hours,

More information

User Guide Westermo Teleindustri AB IDW-90. ISDN Terminaladapter.

User Guide Westermo Teleindustri AB IDW-90. ISDN Terminaladapter. User Guide 6620-2200 IDW-90 Westermo Teleindustri AB ISDN Terminaladapter www.westermo.com Legal information The contents of this document are provided as is. Except as required by applicable law, no warranties

More information

NETWORK. TE = Terminal Equipment (DTE - Data Terminal Equipment) NT = Network - Terminating Equipment (DCE - Data Circuit - Terminating Equipment)

NETWORK. TE = Terminal Equipment (DTE - Data Terminal Equipment) NT = Network - Terminating Equipment (DCE - Data Circuit - Terminating Equipment) NETWORK INTERFACING TE NT NETWORK NT TE Interface Interface TE = Terminal Equipment (DTE - Data Terminal Equipment) NT = Network - Terminating Equipment (DCE - Data Circuit - Terminating Equipment) Interface

More information

1 What s in the shipping package?

1 What s in the shipping package? SST 900B 900 MHz RS 232/RS 485 Wireless Modem Quick Start Guide 1 What s in the shipping package? SST-900B Wireless Modem CA-0910 Quick Start CD 3dBi 900M Hz Antenna Guide 2 External switch introduction

More information

Stat-4 Stat-8 Stat-24

Stat-4 Stat-8 Stat-24 JULY 1993 MX864A MX866A MX868A Stat-4 Stat-8 Stat-24 STAT-4 POWER MAIN 1 2 3 4 SYNC ERR OVF TEST 1 2 3 4 RESET STAT-24 STAT-8 POWER MAIN 1 2 3 4 5 6 7 8 SYNC ERR OVF TEST 1 2 3 4 5 6 7 8 TEST SYNC 23 24

More information

FOM-4SF Sync/Async Single Fiber Modem

FOM-4SF Sync/Async Single Fiber Modem ORDERING FOM-4SF/$/+ Sync/async single fiber modem $ Specify DTE interface type: V24 for V.24 interface, female connector V35 for V.35 interface, female connector X.21 for X.21 interface, female connector

More information

AccessCON-N64 INTERFACE CONVERTER E1/FRACTIONAL E1 TO N64 INSTALLATION AND OPERATION MANUAL. Version 1

AccessCON-N64 INTERFACE CONVERTER E1/FRACTIONAL E1 TO N64 INSTALLATION AND OPERATION MANUAL. Version 1 INTERFACE CONVERTER E1/FRACTIONAL E1 TO N64 INSTALLATION AND OPERATION MANUAL Version 1 Copyright 2005 by S-Access GmbH. The contents of this publication may not be reproduced in any part or as a whole,

More information

Modem RS232/RS422/RS485. to MM optic fibers. RS-232 to Multimode Optic. Fiber Converter. Characteristics DIN rail mounting.

Modem RS232/RS422/RS485. to MM optic fibers. RS-232 to Multimode Optic. Fiber Converter. Characteristics DIN rail mounting. RS-232 to Multimode Optic Modem RS232/RS422/RS485 Fiber Converter to MM optic fibers ELO E14C E17A DIN rail mounting TxD, RxD up to transferring 6km over MM fiber Communication Max. data rate 115.2 protocol

More information

Instruction Manual T5140 T5141 T5145 T5240 T5241 T5245. Programmable transmitter of CO2 concentration with 4-20 ma output. with 0-10 V output

Instruction Manual T5140 T5141 T5145 T5240 T5241 T5245. Programmable transmitter of CO2 concentration with 4-20 ma output. with 0-10 V output www.cometsystem.com Instruction Manual T5140 T5141 T5145 Programmable transmitter of CO2 concentration with 4-20 ma output T5240 T5241 T5245 Programmable transmitter of CO2 concentration with 0-10 V output

More information

1995 Metric CSJ SPECIAL SPECIFICATION ITEM Add/Drop Multiplexor/Demultiplexor

1995 Metric CSJ SPECIAL SPECIFICATION ITEM Add/Drop Multiplexor/Demultiplexor 1995 Metric CSJ 0113-13-109 SPECIAL SPECIFICATION ITEM 6225 Add/Drop Multiplexor/Demultiplexor 1.0 Description. This Item shall govern for the furnishing and installation of intelligent Add/Drop Multiplexor/Demultiplexor

More information

SIN 57 Issue 2.4 May 2018

SIN 57 Issue 2.4 May 2018 SIN 57 Issue 2.4 May 2018 Suppliers' Information Note For The BT Network BT KiloStream X.21 Interface Service Description Each SIN is the copyright of British Telecommunications plc. Reproduction of the

More information

CP485-4 User s Manual

CP485-4 User s Manual CP485x4 User s Manual Version 1.0 2005 ZYPEX, Inc. CP485-4 User s Manual Table of Contents Table of Contents Product Description 1 CP485x4 Configuration & Setup 2 Power 2 Baud Rate 2 Control Mode 2 Duplex

More information

Fanuc Serial (RS232) Communications Information

Fanuc Serial (RS232) Communications Information Memex Automation Inc. 777 Walkers Line, Burlington, Ontario Canada L7N 2G1 Fanuc Serial (RS232) Communications Information Contents Signal Description Fanuc Serial Cable Information Timing Chart When The

More information

APPLICATION NOTE ANI6. Connecting the SP504 Multiprotocol Transceiver to the 85C30 Universal Enhanced Serial Communications Controller (ESCC)

APPLICATION NOTE ANI6. Connecting the SP504 Multiprotocol Transceiver to the 85C30 Universal Enhanced Serial Communications Controller (ESCC) Solved by APPLICATION NOTE ANI6 TM Connecting the SP504 Multiprotocol Transceiver to the 85C30 Universal Enhanced Serial Communications Controller (ESCC) INTRODUCTION The Sipex SP504 is a cost-effective,

More information

Serial Input/Output. Lecturer: Sri Parameswaran Notes by: Annie Guo

Serial Input/Output. Lecturer: Sri Parameswaran Notes by: Annie Guo Serial Input/Output Lecturer: Sri Parameswaran Notes by: Annie Guo 1 Serial communication Concepts Standards USART in AVR Lecture overview 2 Why Serial I/O? Problems with Parallel I/O: Needs a wire for

More information

E205 Long Range Wireless Modem V1.0 Data Sheet

E205 Long Range Wireless Modem V1.0 Data Sheet E205 Long Range Wireless Modem V1.0 Data Sheet The Long Range Wireless Modem E205 is a radio transmitter / receiver designed for transparent wireless data transmission over long distances. It operates

More information

CAB2 Schematic drawing CAB3 CAB4 CAB5. CAB6 Schematic drawing CAB7 Schematic drawing CAB8 Schematic drawing 03315

CAB2 Schematic drawing CAB3 CAB4 CAB5. CAB6 Schematic drawing CAB7 Schematic drawing CAB8 Schematic drawing 03315 CAB1 Schematic drawing 03305 CAB1 SIEMENS Converter 6ES5 734-1BD20 20mA current loop Siemens 15-pos D-sub Male CAB2 Schematic drawing 03301 CAB2 Allen Bradley MicroLogix 8-pos MiniDIN CAB3 Schematic drawing

More information

Production Analyzer Rev (USB + FireWire) Rev. 2.x (USB only)

Production Analyzer Rev (USB + FireWire) Rev. 2.x (USB only) Rev. 1.2-1.6 (USB + FireWire) Rev. 2.x (USB only) Hardware unit for Klippel QC System FEATURES Two channel speaker monitoring Voltage and current Sensors Two channel Microphone Input Built in IEPE Mic

More information

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter Model FLSC-C3-XX DC Powered Microprocessor Controlled Transmitter CONTENTS. Introduction----------------------------------------------------------------- 2 2. Specifications ---------------------------------------------------------------

More information

Dual band E-GSM / GPRS Class 10 / GPS MODEM. GENLoc25. Electronic Hardware Design and Production

Dual band E-GSM / GPRS Class 10 / GPS MODEM. GENLoc25. Electronic Hardware Design and Production Dual band E-GSM / GPRS Class 10 / GPS MODEM GENLoc25 Electronic Hardware Design and Production ERCO & GENER Z.I. Saint Lambert des Levées B.P. 30163-49412 SAUMUR CEDEX - FRANCE Tel. +33 (0)2 41 83 13 00

More information

Industrial PSU with universal input voltage range ( VAC line to line) and configurable output voltage. North America

Industrial PSU with universal input voltage range ( VAC line to line) and configurable output voltage. North America World-Wide 3-phase Input Voltage Range (nom. 200 Vrms to 480 Vrms), PF > 0.94 High Power Density 16 W/in 3 94% Typical Efficiency Parallel Operation up to 16 Units (50.4 kw) Cold-Plate Cooling System -25

More information

An RS485 bus is used for command, monitoring and diagnostic information that can be supplied to a system controller.

An RS485 bus is used for command, monitoring and diagnostic information that can be supplied to a system controller. The TCP3500 series is an AC-DC converter with adjustable DC output and universal 3-phase AC input. Conduction cooling (No Fans) makes this power supply series suitable for a wide variety of Industrial

More information

High-precision process calibrator Model CED7000

High-precision process calibrator Model CED7000 Calibration technology High-precision process calibrator Model CED7000 WIKA data sheet CT 85.51 Applications Research and development laboratories Calibration service companies and service industry Industry

More information

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active Technical manual BA 0318 Signal converter Isolation amplifier active for galvanic isolation, conversion and adjustment of electrical standard signals Evaluable input signals Direct voltage 0...10V / 0...1V

More information

Atrie WireSpan 600/610 MODEM User's Manual

Atrie WireSpan 600/610 MODEM User's Manual Atrie WireSpan 600/610 MODEM User's Manual WireSpan 600 / 610 Fractional E1 Access Unit Installation and Operation manual CONTENTS CHAPTER 1 Interduction.. 1-1 CHAPTER 2 Installation and Setup.. 2-1 CHAPTER

More information

DA 30 High Torque Technical Specification

DA 30 High Torque Technical Specification 1/17 DA 30 High Torque DA 30-HT-30-5848 2/17 Content 1. General Description... 3 2. Operating Data... 4 3. Performance... 5 4. Materials and Protective Features... 6 5. Dimensions... 6 5.1. Installation

More information

ECE 4510/5530 Microcontroller Applications Week 6 Lab 5

ECE 4510/5530 Microcontroller Applications Week 6 Lab 5 Microcontroller Applications Week 6 Lab 5 Dr. Bradley J. Bazuin Associate Professor Department of Electrical and Computer Engineering College of Engineering and Applied Sciences Lab 5 Element Hardware

More information

CROSS Chassis from 160 A to 450 A

CROSS Chassis from 160 A to 450 A CROSS Chassis from 160 A to 450 A STS CATALOGUE Important note! The technical data enclosed is for general information. Please note that the operating instructions and references indicated on the products

More information

CONTROL MICROSYSTEMS SCADAWave Radio Transceiver. Hardware Manual

CONTROL MICROSYSTEMS SCADAWave Radio Transceiver. Hardware Manual 5908 SCADAWave Radio Transceiver Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9 Technical

More information

Installation Instructions. RFID MHz Interface Board for EasyCoder F2 and F4 Printers

Installation Instructions. RFID MHz Interface Board for EasyCoder F2 and F4 Printers Installation Instructions RFID 13.56 MHz Interface Board for EasyCoder F2 and F4 Printers Information in this manual is subject to change without prior notice and does not represent a commitment on the

More information

DECODE. User Manual v1.2n. Multi-standard modem IDM 50B.

DECODE. User Manual v1.2n. Multi-standard modem IDM 50B. Multi-standard modem IDM 50B User Manual v1.2n http://www.decode.co.yu 1. INTRODUCTION 1.1 Modem Overview IDM50B is a multistandard modem for asynchronous or transparent data transmission in 300-3400 Hz

More information

TD-36 TD-36. DIN-rail Tele and Leased Line modem TD DIN-rail Tele and Leased Line modem with I/O and RS-485. User Guide

TD-36 TD-36. DIN-rail Tele and Leased Line modem TD DIN-rail Tele and Leased Line modem with I/O and RS-485. User Guide User Guide 6618-2202 TD-36 Westermo Teleindustri AB TD-36 DIN-rail Tele and Leased Line modem TD-36 485 DIN-rail Tele and Leased Line modem with I/O and RS-485 www.westermo.com Legal information The contents

More information

LCM100 USER GUIDE. Line Carrier Modem INDUSTRIAL DATA COMMUNICATIONS

LCM100 USER GUIDE. Line Carrier Modem INDUSTRIAL DATA COMMUNICATIONS USER GUIDE INDUSTRIAL DATA COMMUNICATIONS LCM100 Line Carrier Modem It is essential that all instructions contained in the User Guide are followed precisely to ensure proper operation of equipment. Product

More information

LDM85. Fiber Optic Modem. Description. Features. Specifications

LDM85. Fiber Optic Modem. Description. Features. Specifications 6 Fiber Optic Modem Description he is a small, inexpensive fiber optic transmitter/receiver. It features a complete S- port as well as high speed L/S- /S- data transmit and receive. It is capable of data

More information

1.0 Introduction. Related Products and Documentation

1.0 Introduction. Related Products and Documentation Quick Start t Guide ER450 Data Radio 1.0 Introduction Welcome to the Quick Start Guide for the ER450 Data Radio. This guide provides step-by-step instructions, with simple explanations to get you up-and-running.

More information

USER MANUAL MODEL Time Division Multiplexor, RS-232 (CTS TDM-V.24) SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL MODEL Time Division Multiplexor, RS-232 (CTS TDM-V.24) SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 3042 (CTS TDM-V.24) Time Division Multiplexor, RS-232 Part #: 07M3042-A Doc #: 119001UA Revised 3/26/01 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0 WARRANTY INFORMATION

More information

Confirm entry value Set display to value from Actual value and input display Select datum P79 (P80!) (7-segment LED,

Confirm entry value Set display to value from Actual value and input display Select datum P79 (P80!) (7-segment LED, HEIDENHAIN Working with the measured value display unit ND 261 Confirm entry value Set display to value from Actual value and input display Select datum P79 (P80!) (7-segment LED, Page backward in 9 decades

More information