How to make a list sweep measurement

Size: px
Start display at page:

Download "How to make a list sweep measurement"

Transcription

1 How to make a list sweep measurement This material shows how to perform a list sweep measurement through an example of the Photovoltaic Cell IV measurement. Figure 1 illustrates the connection and condition supposed in the example of measuring Photovoltaic Cell using the B2901/02/11/12A. B2901/02/11/12A A - V - High Force DUT Low Force Figure 1. Connection and condition supposed in the example Figure 2 shows the timing chart for the list sweep measurement with the front panel operation. In this case, the specified source value is sourced immediately after turning on. Then, when you press, the instrument will make a list sweep measurement. If it is necessary, you can specify any measurement trigger delay time which is the wait time after sourcing each source value and before making a measurement. The measurement time consists of Measurement Speed and some overhead time. Measurement Speed is the parameter specified by the user. Overhead time includes the time to change the measurement range, etc. V or I V2 Value T P T M : Trigger Period : Measurement Time T MD T M T MD : Measurement Trigger Delay Time :Measurement V4 Value T MD T M T MD T M V3 Value Source Value T MD T M V1 Value Output Off State Output ON Press Trigger T P T P T P Internal Trigger Internal Trigger Internal Trigger T P Time Figure 2. Timing chart for the list sweep measurement

2 Preparing the list data in advance When you source some complicated waveform with the List Sweep Mode of the B2901/02/11/12A, it is convenient to create the data list on a PC using the software of your choice and then transfer the data list file to the B2901/02/11/12A via USB flash memory. TXT, PRN and CSV file format are available for data list file. Step 1. Develop CSV file which includes the following source list data. (From 0 to 0.7 with 0.1 step, and from 0.71 to 1.30 with 0.01 step, and from 1.4 to 1.7 with 0.1 step) Step 2. Save CSV file as listdata.csv to the root folder of your USB flash memory device. Step 3. Attach the USB flash memory device which listdata.csv file is saved to the USB port on the front panel of the B2901/02/11/12A. Agilent B2900A Quick I/V Measurement Software is also available to edit the data list for List Sweep Mode. Please refer to the Agilent Web Site below for the detailed information about Agilent B2900A Quick I/V Measurement Software.

3 Performing a list sweep measurement Step 1. Press repeatedly until Single View for Channel 1 is shown in the display. Step 2. Press to edit the source function, and then select to set the source function to the voltage source. (1) Press Mode (2) Press VOLTS (V) Step 3. Press to edit the source value, and then enter 0 V to set the source value to 0 V. (1) Press Source (2) Enter Source Value Step 4. Press to edit the limit value, and then enter 100 ma to set the limit value to 100 ma. (1) Press Limit (2) Enter Limit Value Step 5. Press to configure the measurement parameter, and then select to set the measurement parameter to the current. (1) Press Measure (2) Press AMPS (I)

4 Step 6. Press to change the keys shown in Assist keys, and then press to show Sweep Sub-Panel. (1) Press Show Sweep (2) Sweep Sub-Panel appears Step 7. Press, then press to change the keys shown in Assist keys. (1) Press (2) Press More... Step 8. Press to turn on List Sweep Mode. After turning on List Sweep Mode, you can see Source Shape which shows the list sweep mode. (1) Press LIST Source Shape Step 9. Rotate and press to edit Start value and press to open Load List Sweep Data dialogue. Start value to edit (2) Press Load

5 Step 10. Rotate and press to select listdata.csv file, and then press to load listdata.csv file. listdata.csv file to select (2) Press OK to load listdata.csv file Now you have configured List Sweep Source Setup and can see the parameters bellow. Step 11. Press repeatedly until Graph View is shown in the display. Step 12. Press to source the voltage, and then press to perform a measurement. (The status information will show during the measurement.) Step 13. Press to adjust the scale of the graph after finishing the measurement. Now you can see the measurement result on the GUI of the B2901/02/11/12A as bellow.

6 Step 14. Rotate and press to edit the Y-axis maximum value, and then enter 0 A to adjust the graph scale. Y-axis maximum value to select (2) Enter the scale such as 0 A Step 15. Rotate and press to edit the Y-axis minimum value, and then enter -80 ma to adjust the graph scale. Y-axis minimum value to select (2) Enter the scale such as -80 ma Now you can see the measurement result scaled on the GUI of the B2901/02/11/12A as bellow.

7 Configuring the measurement speed In the default setting, the instrument selects the appropriate measurement speed and range automatically to get the fine accuracy. However, you can also specify these parameters on the GUI of the B2901/02/11/12A to meet a variety of the requirement to the measurement conditions. For example, let s try to change the measurement speed to NORMAL to make a measurement more carefully. If you select NORMAL, the aperture time is set to 1 PLC. Here, PLC stands for power line cycle and the specified number of power line cycles is used per a measurement. Step 1. Press repeatedly until Single View for Channel 1 is shown in the display. Step 2. Press to edit the measurement speed, and then select to set the measurement speed to NORMAL. (If you can t see in Assist keys, press to change the keys shown in Assist keys.) (1) Press Speed (2) Press NORMAL Configuring the measurement range operation The parameters which configure the measurement range operation can be displayed in Range Sub-panel in Single View, although Sweep Sub-Panel is shown at this moment. In the default setting, the B2901/02/11/12A performs the current measurement using 1 ua current minimum measurement range with AUTO range operation. With AUTO range operation, the B2901/02/11/12A selects the proper range for the measurement with specified minimum measurement range so that you don t need to take care about it. To know how to change the measurement range setting, try to configure to use 10 na current minimum measurement range with AUTO range operation. Step 1. Press to show Range Sub-Panel. (If you can t see in Assist keys, press to change the keys shown in Assist keys.) (1) Press More... (if necessary) (2) Press Hide Sweep

8 Step 2. Rotate and press to edit the current minimum measurement range, and then select to set it to 10 na. to edit Current Minimum Measurement Range (2) Press 10nA If you d like to fix the measurement range, you can select FIXED range operation as below. Step 3. Rotate and press to edit the current measurement range operation. Then Select to set the current measurement range operation to FIXED. to edit Current Measurement Range Operation (2) Press FIXED Configuring the measurement trigger delay time The trigger parameters including the measurement trigger delay time and the trigger period can be displayed in Trigger Sub-panel in Single View, although Range Sub-Panel is shown at this moment. In the default setting, the trigger type is set to the automatic trigger type (AUTO) so that you don t need to specify these trigger parameters. If you d like to specify the measurement trigger delay time, take the following steps. Step 1. Press to show Trigger Sub-Panel. (If you can t see in Assist keys, press to change the keys shown in Assist keys.) (1) Press More... (if necessary) (2) Press Show Trigger

9 Step 2. Press to edit the trigger type, and then select to set the trigger type to MANUAL. (1) Press (2) Press MANUAL Step 3. Rotate to select Channel 1 Trigger Parameters and set them up as below. (Source Trigger Count: 72, Measurement Trigger Count: 72, Measurement Trigger Delay Time: 100ms) Note) Source and Measurement Trigger Count should be the same number as Sweep Points. Now you ve configured 100 ms measurement trigger delay time. Configuring the trigger period If you need to control the source and measurement period strictly, the trigger period is useful to make it. In order to specify the trigger period, take the following steps. Step 1. Rotate and press to edit the trigger type, and then select to set the trigger type to TIMER. Trigger Type to edit (2) Press TIMER

10 Step 2. Rotate to select Channel 1 Trigger Parameters and set them up as below. (Source Trigger Period 400 ms, Measurement Trigger Period: 400 ms) Note) Source and Measurement Period should be the same as each other. Now you ve configured 400 ms trigger period. However, please note that FIXED current measurement range operation will be used to control the trigger period strictly. The measurement range is selected by Limit value. In this example, 100 ma measurement range will be used. If using AUTO measurement range operation is prior to controlling the trigger period strictly, you may specify MANUAL trigger type with AUTO source and measurement trigger source by the following steps. Step 3. Press to edit the trigger type, and then select to set the trigger type to MANUAL. Trigger Type to edit (2) Press MANUAL Step 4. Rotate to select Channel 1 Trigger Parameters and set them up as below. (Source Trigger Source: AUTO, Measurement Trigger Source: AUTO)

11 Viewing the list of measurement results The measurement results including the measurement time stamp can be referred by the following steps. Step 1. If you aren t on the top of the Function menu, press repeatedly to return to the top level. On the top level of the Function menu Any tree structure can t be seen In the middle level of the Function menu Some tree structure can be seen Step 2. If you d like to see the list of measurement results, press, then press to open Measure Result dialogue. (1) Press Result (2) Press Measure Step 3. Rotate and press to select Data Type field. (1) Rotate field to select Data Type (2) Press to select Data Type Step 4. Press to change the keys shown in Assist keys, and then press to select Time as the data type. (1) Press More (2) Press TIME (t)

12 Step 5. Rotate and press to select Data field. Then rotate to scroll the data list. Data field to select (2) Rotate to scroll the list or press Assist key

How to make a sampling measurement with continuous source

How to make a sampling measurement with continuous source How to make a sampling measurement with continuous source Agilent B2901/02/11/12A Precision Source/Measure Unit This material shows how to perform a sampling measurement through an example of sourcing

More information

How to make a single point measurement

How to make a single point measurement How to make a single point measurement This material shows how to perform a single point measurement through an example of the forward voltage test of diode. Figure 1 illustrates the connection and condition

More information

How to source exponential waveform

How to source exponential waveform How to source exponential waveform This material shows how to source exponential waveform using an example to source it to 1 kohm resistor. Figure 1 illustrates the connection and condition supposed in

More information

How to realize Low Current Measurement with Agilent B2901/02/11/12A

How to realize Low Current Measurement with Agilent B2901/02/11/12A How to realize Low Current Measurement with Agilent B2901/02/11/12A The Agilent B2901/02/11/12A has higher current measurement resolution (10 fa for B2911/12A, 100 fa for B2901/02A) so that it has the

More information

Keysight Technologies Making Field Effect Transistor Characterization Using SMU

Keysight Technologies Making Field Effect Transistor Characterization Using SMU Keysight Technologies Making Field Effect Transistor Characterization Using SMU B2900A Precision Source/Measure Unit Demo Guide Introduction The Keysight s B2900A Series Precision Source/Measure Unit (SMU)

More information

How to configure trigger output signals

How to configure trigger output signals How to configure trigger output signals This material shows how to configure the instrument to output the trigger signals at the specified timing using Agilent B2961A/B2962A Power Source, through an example

More information

Keysight Technologies Photodiode Test Using the Keysight B2980A Series

Keysight Technologies Photodiode Test Using the Keysight B2980A Series Keysight Technologies Photodiode Test Using the Keysight B2980A Series B2981A/83A Femto/Picoammeter B2985A/87A Electrometer/High Resistance Meter Application Note Introduction A photodiode (PD) is a semiconductor

More information

Measuring Insulating Material Resistivity Using the B2985A/87A

Measuring Insulating Material Resistivity Using the B2985A/87A APPLICATION NOTE Measuring Insulating Material Resistivity Using the B2985A/87A Keysight B2985A/B2987A Electrometer/High Resistance Meter Introduction The Keysight B2985A and B2987A Electrometer/High Resistance

More information

Keysight Technologies Making Current-Voltage Measurement Using SMU

Keysight Technologies Making Current-Voltage Measurement Using SMU Keysight Technologies Making Current-Voltage Measurement Using SMU Keysight B2901A/02A/11A/12A Precision Source/Measure Unit Demonstration Guide Introduction The Keysight Technologies, Inc. B2901A/02A/11A/12A

More information

Keysight Technologies Using an External Trigger to Generate Pulses with the B2960A

Keysight Technologies Using an External Trigger to Generate Pulses with the B2960A Keysight Technologies Using an External Trigger to Generate Pulses with the B2960A B2960A 6.5 Digit Low Noise Power Source Demo Guide 02 Keysight Using an External Trigger to Generate Pulses with the B2960A

More information

LV8716QAGEVK Evaluation Kit User Guide

LV8716QAGEVK Evaluation Kit User Guide LV8716QAGEVK Evaluation Kit User Guide NOTICE TO CUSTOMERS The LV8716QA Evaluation Kit is intended to be used for ENGINEERING DEVELOPMENT, DEMONSTRATION OR EVALUATION PURPOSES ONLY and is not considered

More information

Keysight Technologies Measuring Insulating Material Resistivity Using the B2985A/87A

Keysight Technologies Measuring Insulating Material Resistivity Using the B2985A/87A Keysight Technologies Measuring Insulating Material Resistivity Using the B2985A/87A Keysight B2985A/B2987A Electrometer/High Resistance Meter Application Note Introduction The Keysight B2985A and B2987A

More information

LAUNCHPAD. Getting Started Guide

LAUNCHPAD. Getting Started Guide LAUNCHPAD Getting Started Guide Overview Launchpad Thank you for buying Launchpad, the iconic grid instrument for Ableton Live. You re now part of the evolution in the creation of electronic music! The

More information

Version Futek Instruments, LLC

Version Futek Instruments, LLC FT_ez_DAQ User s Manual Version 2.0.0 Futek Instruments, LLC Table of Contents 1. Introduction... 3 2. System Requirements... 3 3. Software Installation... 4 3.1 Application software and USB driver installation...

More information

Veterinary Digital X-Ray System Quick Start Guide

Veterinary Digital X-Ray System Quick Start Guide 1 Veterinary Digital X-Ray System Quick Start Guide 2 SOPIX² X-Ray Sensors Quick Start Guide ***PERFORM THIS STEP BEFORE PLUGGING IN THE SENSOR*** Step 1 Load the CD: If you have already plugged in the

More information

Keysight Technologies Capacitance Leakage Current Measurement Techniques Using the B2985A/87A

Keysight Technologies Capacitance Leakage Current Measurement Techniques Using the B2985A/87A Keysight Technologies Capacitance Leakage Current Measurement Techniques Using the B2985A/87A B2985A/B2987A Electrometer/High Resistance Meter Technical Overview Introduction Capacitor leakage current

More information

Keysight Technologies Measuring Insulating Material Resistivity Using the B2985A/87A

Keysight Technologies Measuring Insulating Material Resistivity Using the B2985A/87A Keysight Technologies Measuring Insulating Material Resistivity Using the B2985A/87A Keysight B2985A/B2987A Electrometer/High Resistance Meter Technical Overview Introduction The Keysight B2985A and B2987A

More information

Agilent FieldFox RF Analyzer N9912A

Agilent FieldFox RF Analyzer N9912A Agilent FieldFox RF Analyzer N9912A Quick Reference Guide Contents Do You Have Everything?... 2 The Power Button and LED... 2 Battery Usage... 3 Measure Return Loss... 4 Measure Cable Loss (1-Port)...

More information

ME 365 EXPERIMENT 1 FAMILIARIZATION WITH COMMONLY USED INSTRUMENTATION

ME 365 EXPERIMENT 1 FAMILIARIZATION WITH COMMONLY USED INSTRUMENTATION Objectives: ME 365 EXPERIMENT 1 FAMILIARIZATION WITH COMMONLY USED INSTRUMENTATION The primary goal of this laboratory is to study the operation and limitations of several commonly used pieces of instrumentation:

More information

Agilent U2000 Series USB Power Sensors. Data Sheet

Agilent U2000 Series USB Power Sensors. Data Sheet Agilent U2000 Series USB Power Sensors Data Sheet Features Perform power measurement without a power meter Frequency range from 9 khz to 24 GHz (sensor dependent) Dynamic range from 60 dbm to +20 dbm Internal

More information

LabVIEW Day 2: Other loops, Other graphs

LabVIEW Day 2: Other loops, Other graphs LabVIEW Day 2: Other loops, Other graphs Vern Lindberg From now on, I will not include the Programming to indicate paths to icons for the block diagram. I assume you will be getting comfortable with the

More information

EXPERIMENT NUMBER 2 BASIC OSCILLOSCOPE OPERATIONS

EXPERIMENT NUMBER 2 BASIC OSCILLOSCOPE OPERATIONS 1 EXPERIMENT NUMBER 2 BASIC OSCILLOSCOPE OPERATIONS The oscilloscope is the most versatile and most important tool in this lab and is probably the best tool an electrical engineer uses. This outline guides

More information

Quick Start Guide for the PULSE PROFILING APPLICATION

Quick Start Guide for the PULSE PROFILING APPLICATION Quick Start Guide for the PULSE PROFILING APPLICATION MODEL LB480A Revision: Preliminary 02/05/09 1 1. Introduction This document provides information to install and quickly start using your PowerSensor+.

More information

IXIAN TM class V 1.5. EC Transmitter This is an evolving document. EC Transmitter IXIAN TM. Features

IXIAN TM class V 1.5. EC Transmitter This is an evolving document. EC Transmitter IXIAN TM. Features class V 1.5 EC Transmitter This is an evolving document check back for updates. Features 4 20mA output Reads conductivity from 0.07µs to 100,000µs Accuracy +/- 2% Calibrate remotely through a PLC or directly

More information

Downloading a ROBOTC Sample Program

Downloading a ROBOTC Sample Program Downloading a ROBOTC Sample Program This document is a guide for downloading and running programs on the VEX Cortex using ROBOTC for Cortex 2.3 BETA. It is broken into four sections: Prerequisites, Downloading

More information

Tetra Base Station Test and Monitoring

Tetra Base Station Test and Monitoring Tetra Base Station Test and Monitoring Introduction to Tetra Base Station Test and Monitoring The two options TETRA Base Station Monitoring ( R8-TETRA_BSM) and TETRA Base Station T1 Test (R8-TETRA_BST1)

More information

Discovering New Techniques of Creating, Editing, and Transferring Arbitrary Waveforms With the Agilent U2761A Function/Arbitrary Waveform Generator

Discovering New Techniques of Creating, Editing, and Transferring Arbitrary Waveforms With the Agilent U2761A Function/Arbitrary Waveform Generator Discovering New Techniques of Creating, Editing, and Transferring Arbitrary Waveforms With the Agilent U2761A Function/Arbitrary Waveform Generator Reprinted courtesy Agilent Technologies Introduction

More information

Bench LCR Meter Model 891

Bench LCR Meter Model 891 Data Sheet Bench LCR Meter The 891 is a compact, precise, and versatile LCR meter capable of measuring inductors, capacitors, and resistors at DC or from 20 Hz to 300 khz. The instrument s 2U half-rack

More information

An Introductory Guide to Circuit Simulation using NI Multisim 12

An Introductory Guide to Circuit Simulation using NI Multisim 12 School of Engineering and Technology An Introductory Guide to Circuit Simulation using NI Multisim 12 This booklet belongs to: This document provides a brief overview and introductory tutorial for circuit

More information

Low-Cost Power Sources Meet Advanced ADC and VCO Characterization Requirements

Low-Cost Power Sources Meet Advanced ADC and VCO Characterization Requirements Low-Cost Power Sources Meet Advanced ADC and VCO Characterization Requirements Our thanks to Agilent Technologies for allowing us to reprint this article. Introduction Finding a cost-effective power source

More information

Antenna and Propagation

Antenna and Propagation Antenna and Propagation This courseware product contains scholarly and technical information and is protected by copyright laws and international treaties. No part of this publication may be reproduced

More information

Keysight B1505A Power Device Analyzer/Curve Tracer

Keysight B1505A Power Device Analyzer/Curve Tracer Keysight B1505A Power Device Analyzer/Curve Tracer For the tests up to 40 A/ 3000 V by Dual HCSMU/ HVSMU Quick Start Guide Table of Contents Before Using B1505A 3 Instruments and Accessories used in this

More information

ScopeMeter Test Tool CSV files available for FlukeView software and Microsoft Excel Application Note

ScopeMeter Test Tool CSV files available for FlukeView software and Microsoft Excel Application Note ScopeMeter Test Tool CSV files available for FlukeView software and Microsoft Excel Application Note Introduction Capturing critical waveform information to be used as a comparison reference point, or

More information

Conductivity +/ 2% 1 or 2 point remotely through PLC or directly on board. Any two lead Conductivity probe (K 0.01, K 0.1, K 1.

Conductivity +/ 2% 1 or 2 point remotely through PLC or directly on board. Any two lead Conductivity probe (K 0.01, K 0.1, K 1. V 2.0 Revised 1/16/17 Conductivity IXIAN Transmitter Reads Range Accuracy Calibration Supported probes Temp probe Conductivity 0.07µS 100,000µS +/ 2% 1 or 2 point remotely through PLC or directly on board

More information

Shimadzu RF-5301 Fluorimeter operation guide for students

Shimadzu RF-5301 Fluorimeter operation guide for students Department of Chemistry Teaching Laboratories Shimadzu RF-5301 Fluorimeter operation guide for students General directions Detailed instructions for use of the fluorimeter may be given in the lab script,

More information

WCS-D5100 Programming Software for the Icom ID-5100 Data

WCS-D5100 Programming Software for the Icom ID-5100 Data WCS-D5100 Programming Software for the Icom ID-5100 Data Memory Types (left to right) Memories Limit Memories DR Memories Call Channels GPS Memories Receive Frequency Transmit Frequency Offset Frequency

More information

Agilent U8903A Audio Analyzer

Agilent U8903A Audio Analyzer Agilent U8903A Audio Analyzer Fast and accurate multi-channels audio analysis made affordable (Replacement of the HP 8903B) Page 1 Agilent Restricted New U8903A Audio Analyzer Replacing the Popular HP

More information

IX Feb Operation Guide. Sequence Creation and Control Software SD011-PCR-LE. Wavy for PCR-LE. Ver. 5.5x

IX Feb Operation Guide. Sequence Creation and Control Software SD011-PCR-LE. Wavy for PCR-LE. Ver. 5.5x IX000693 Feb. 015 Operation Guide Sequence Creation and Control Software SD011-PCR-LE Wavy for PCR-LE Ver. 5.5x About This Guide This PDF version of the operation guide is provided so that you can print

More information

EE EXPERIMENT 1 (2 DAYS) BASIC OSCILLOSCOPE OPERATIONS INTRODUCTION DAY 1

EE EXPERIMENT 1 (2 DAYS) BASIC OSCILLOSCOPE OPERATIONS INTRODUCTION DAY 1 EE 2101 - EXPERIMENT 1 (2 DAYS) BASIC OSCILLOSCOPE OPERATIONS INTRODUCTION The oscilloscope is the most versatile and most important tool in this lab and is probably the best tool an electrical engineer

More information

PSM Soft. Features and Functions January PC Software Guide. Getting connected and Communication

PSM Soft. Features and Functions January PC Software Guide. Getting connected and Communication PSM Soft PC Software Guide Features and Functions January 2010 The PSM series Phase Sensitive Multimeters provide a wide range of exceptionally accurate and versatile instrumentation in one unique package.

More information

Keysight Technologies Measuring Low Current Consumption with a Digital Multimeter

Keysight Technologies Measuring Low Current Consumption with a Digital Multimeter Keysight Technologies Measuring Low Current Consumption with a Digital Multimeter Application Brief Test Challenges: Characterizing the power consumption of a battery powered device Testing the current

More information

PGT313 Digital Communication Technology. Lab 6. Spectrum Analysis of CDMA Signal

PGT313 Digital Communication Technology. Lab 6. Spectrum Analysis of CDMA Signal PGT313 Digital Communication Technology Lab 6 Spectrum Analysis of CDMA Signal Objectives i) To measure the channel power of a CDMA modulated RF signal using an oscilloscope and the VSA software ii) To

More information

TOSHIBA MACHINE CO., LTD.

TOSHIBA MACHINE CO., LTD. User s Manual Product SHAN5 Version 1.12 (V Series Servo Amplifier PC Tool) Model SFV02 July2005 TOSHIBA MACHINE CO., LTD. Introduction This document describes the operation and installation methods of

More information

MT3500 Hand-Held Engine Analyzer Safety Operation Regulations

MT3500 Hand-Held Engine Analyzer Safety Operation Regulations MT3500 Hand-Held Engine Analyzer Safety Operation Regulations - 1 - Chapter One Introduction A. Notice of Usage: MT3500 Hand-Held Engine Analyzer must be operated by trained professionals, who must know

More information

Keysight Technologies How to Take Fast, Simultaneous Measurements of Two or More Signals Using BenchVue Software. Application Note

Keysight Technologies How to Take Fast, Simultaneous Measurements of Two or More Signals Using BenchVue Software. Application Note Keysight Technologies How to Take Fast, Simultaneous Measurements of Two or More Signals Using BenchVue Software Application Note 02 Keysight How to Take Fast, Simultaneous Measurements of Two or More

More information

Photoshop CS part 2. Workshop Objective. Getting Started Quit all open applications Single click Adobe Photoshop from the Dock

Photoshop CS part 2. Workshop Objective. Getting Started Quit all open applications Single click Adobe Photoshop from the Dock pg. 1 Photoshop CS part 2 Photoshop is the premier digital photo editor application used for photo retouching, creating web images, film/video compositing, and other pixel/vector-based imagery. Workshop

More information

Mach 5 100,000 PPS Energy Meter Operating Instructions

Mach 5 100,000 PPS Energy Meter Operating Instructions Mach 5 100,000 PPS Energy Meter Operating Instructions Rev AF 3/18/2010 Page 1 of 45 Contents Introduction... 3 Installing the Software... 4 Power Source... 6 Probe Connection... 6 Indicator LED s... 6

More information

Table of Contents. Chapter 1: Software Installation...1. Chapter 2: Running the Software II. Daily Practical Operation...10

Table of Contents. Chapter 1: Software Installation...1. Chapter 2: Running the Software II. Daily Practical Operation...10 Product Manual Table of Contents Chapter 1: Software Installation.................................1 Chapter 2: Running the Software............................... 2 I. The Initial Defining in Lock Management

More information

Motion Blur with Mental Ray

Motion Blur with Mental Ray Motion Blur with Mental Ray In this tutorial we are going to take a look at the settings and what they do for us in using Motion Blur with the Mental Ray renderer that comes with 3D Studio. For this little

More information

Instruction Sheet OM-EL-USB-5. Counter, Event and State USB Data Logger

Instruction Sheet OM-EL-USB-5. Counter, Event and State USB Data Logger Instruction Sheet OM-EL-USB-5 Counter, Event and State USB Data Logger OM-EL-USB-5 Counter, Event and State USB Data Logger FEATURES ORDERING INFORMATION Standard Data Logger (Data Logger, Software on

More information

The Perception. Is Reality. Test Bench

The Perception. Is Reality. Test Bench Test Bench The Perception Y ou would be hard-pressed to find an automotive technician who has not used an oscilloscope to diagnose a particular problem. Most technicians either own a scope or are planning

More information

Revision 1. March 21, ADC Operation Manual N 11 th St San Jose CA

Revision 1. March 21, ADC Operation Manual N 11 th St San Jose CA Revision 1 March 21, 2017 ADC Operation Manual www.mountztorque.com - 1080 N 11 th St San Jose CA 95112 408.292.2214 1 Index 1. Installation 3 1.1 Required PC specification 3 1.2 Software 3 2. Operation

More information

Experiment P-10 Ohm's Law

Experiment P-10 Ohm's Law 1 Experiment P-10 Ohm's Law Objectives To study the relationship between the voltage applied to a given resistor and the intensity of the current running through it. Modules and Sensors PC + NeuLog application

More information

AA-35 ZOOM. RigExpert. User s manual. Antenna and cable analyzer

AA-35 ZOOM. RigExpert. User s manual. Antenna and cable analyzer AA-35 ZOOM Antenna and cable analyzer RigExpert User s manual . Table of contents Introduction Operating the AA-35 ZOOM First time use Main menu Multifunctional keys Connecting to your antenna SWR chart

More information

1 Radar calibration at first installation

1 Radar calibration at first installation 1 Radar calibration at first installation At first installation is necessary to properly calibrate the radar. This includes: Heading Line Transmission Trigger Delay Antenna Parking Position (only MDS 9

More information

Agilent U1253B True RMS OLED Multimeter. Quick Start Guide

Agilent U1253B True RMS OLED Multimeter. Quick Start Guide Agilent U1253B True RMS OLED Multimeter Quick Start Guide The following items are included with your multimeter: Silicone test leads 4 mm probes Alligator clips Printed Quick Start Guide Rechargeable 8.4

More information

Faculty of Electrical & Electronics Engineering BEE4233 Antenna and Propagation. LAB 1: Introduction to Antenna Measurement

Faculty of Electrical & Electronics Engineering BEE4233 Antenna and Propagation. LAB 1: Introduction to Antenna Measurement Faculty of Electrical & Electronics Engineering BEE4233 Antenna and Propagation LAB 1: Introduction to Antenna Measurement Mapping CO, PO, Domain, KI : CO2,PO3,P5,CTPS5 CO1: Characterize the fundamentals

More information

Revision Date: 6/6/2013. Quick Start Guide

Revision Date: 6/6/2013. Quick Start Guide Revision Date: 6/6/2013 Quick Start Guide Important Notice Copyright 2013Frontline Test Equipment. All rights reserved. i Important Notice Table of Contents Purpose 1 Minimum Hardware Requirements 1 Internet

More information

Keysight Technologies Precise Low Resistance Measurements Using the B2961A and 34420A

Keysight Technologies Precise Low Resistance Measurements Using the B2961A and 34420A Keysight Technologies Precise Low Resistance Measurements Using the B2961A and 34420A B2961A/B2962A 6.5 Digit Low Noise Power Source Application Note Introduction Resistance measurement is one of the most

More information

Quick Start. DTA Self-Install Guide

Quick Start. DTA Self-Install Guide Quick Start DTA Self-Install Guide 1 step Installing Your Rainbow HD Digital Transport Adapter (DTA) Your kit contains the following items needed for connecting your DTA to your TV*: DTA Box Coax Cable

More information

Power Supply Selector Guide

Power Supply Selector Guide Tektronix and Keithley Power Supply Selection Guide Brand Model Channel Power Programmable Tektronix PWS2185 1 90 W 18 V 5 A N/A Tektronix PWS2323 1 96 W 32 V 3 A N/A Tektronix PWS2326 1 192 W 32 V 6 A

More information

inphoto ID Canon and Olympus camera control software Automatic ID photography User Guide

inphoto ID Canon and Olympus camera control software Automatic ID photography User Guide inphoto ID Canon and Olympus camera control software Automatic ID photography User Guide 2006 Akond company 197342, Russia, St.-Petersburg, Serdobolskaya, 65a Phone/fax: +7(812)600-6918 Cell: +7(921)757-8319

More information

Author: Dr.Chen-Hanson Ting

Author: Dr.Chen-Hanson Ting DS203 USER'S MANUAL Author: Dr.Chen-Hanson Ting Contents 1.Introduction Major Features Safety Operation conditions General Inspection Functional Inspection Firmware Upgrade 2.Oscilloscope Operations Interfaces

More information

ROOMPLAYER GUIDE COMPLETE YOUR ROOMPLAYER SETUP WITH THE ROOMPLAYER DESKTOP APP

ROOMPLAYER GUIDE COMPLETE YOUR ROOMPLAYER SETUP WITH THE ROOMPLAYER DESKTOP APP ROOMPLAYER GUIDE COMPLETE YOUR ROOMPLAYER SETUP WITH THE ROOMPLAYER DESKTOP APP HELLO Once you ve connected your Roomplayer to your home network, downloading and installing the Roomplayer desktop app is

More information

Making Sense of Wireless Sensor Power Consumption. Steven Lee Application Engineer

Making Sense of Wireless Sensor Power Consumption. Steven Lee Application Engineer Making Sense of Wireless Sensor Power Consumption Steven Lee Application Engineer Agenda The importance of optimizing power consumption on sensors Test Case: Tire Pressure Monitor Sensor Traditional approach

More information

LincView OPC USER GUIDE. Enhanced Diagnostics Utility INDUSTRIAL DATA COMMUNICATIONS

LincView OPC USER GUIDE. Enhanced Diagnostics Utility INDUSTRIAL DATA COMMUNICATIONS USER GUIDE INDUSTRIAL DATA COMMUNICATIONS LincView OPC Enhanced Diagnostics Utility It is essential that all instructions contained in the User Guide are followed precisely to ensure proper operation of

More information

Configuring a Mitsubishi PLC CC-Link Network

Configuring a Mitsubishi PLC CC-Link Network Configuring a Mitsubishi PLC CC-Link Network Author: Sam Stewart/Kade Olson Date: May 10, 2017 Introduction AcraDyne Gen IV Controllers are available with CC-Link (Version 1 and 2) communication capability.

More information

54645D. Mixed Signal Oscilloscope

54645D. Mixed Signal Oscilloscope 54645D Mixed Signal Oscilloscope Page 1 of 42 Instructions for the use of the 54645D Mixed Signal Oscilloscope This pamphlet is intended to give you (the student) an overview on the use of the 54645D Mixed

More information

Nikon D300 Custom Functions

Nikon D300 Custom Functions Nikon D300 Custom Functions This spreadsheet allows you to record the custom functions saved in each menu and bank on the camera. I've carefully laid out the tabs and menus to match the camera as exactly

More information

Operator Manual 1.4 FRACSIM MINI

Operator Manual 1.4 FRACSIM MINI FracSim Meters FracSim Meters was founded with the intention of providing specifically designed tools for the well service industry. Our goal is to provide quality tools with a robust design to meet the

More information

The operator interface consists of an LCD and eight keys. Use the interface to program and operate the triggering controller.

The operator interface consists of an LCD and eight keys. Use the interface to program and operate the triggering controller. Nordson Corporation OPERATOR S CARD P/N 1017461C Sure Coat Triggering Controller Operator Interface WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions

More information

Rodni What will yours be?

Rodni What will yours be? Rodni What will yours be? version 4 Welcome to Rodni, a modular animatronic animal of your own creation for learning how easy it is to enter the world of software programming and micro controllers. During

More information

Oscilloscope Measurements

Oscilloscope Measurements PC1143 Physics III Oscilloscope Measurements 1 Purpose Investigate the fundamental principles and practical operation of the oscilloscope using signals from a signal generator. Measure sine and other waveform

More information

Instruction Manual for the Software of ASSAN V2 Series Receiver

Instruction Manual for the Software of ASSAN V2 Series Receiver Instruction Manual for the Software of ASSAN V2 Series Receiver I. Setup 1. Double click SETUP to enter the welcome interface and click Next. 2. Enter your name and company name and click Next. 3. Select

More information

FPGA SI Tutorial - Simulating the Reflection Characteristics

FPGA SI Tutorial - Simulating the Reflection Characteristics FPGA SI Tutorial - Simulating the Reflection Characteristics Old Content - visit altium.com/documentation Modified by Admin on Sep 13, 2017 Now that things are setup we can simulate the reflection characteristics

More information

FAST TRACK READ ME FIRST! FAST TRACK E300 A Quick-Start Guide to Installing and Using Your COOLPIX 300. Contents. Nikon View... 25

FAST TRACK READ ME FIRST! FAST TRACK E300 A Quick-Start Guide to Installing and Using Your COOLPIX 300. Contents. Nikon View... 25 READ ME FIRST! FAST TRACK FAST TRACK E300 A Quick-Start Guide to Installing and Using Your COOLPIX 300 Contents Checklist Before you begin... 2 Using the COOLPIX 300... 4 GETTING TO KNOW YOUR COOLPIX 300...

More information

Servo Tuning Tutorial

Servo Tuning Tutorial Servo Tuning Tutorial 1 Presentation Outline Introduction Servo system defined Why does a servo system need to be tuned Trajectory generator and velocity profiles The PID Filter Proportional gain Derivative

More information

September CoroCAM 6D. Camera Operation Training. Copyright 2012

September CoroCAM 6D. Camera Operation Training. Copyright 2012 CoroCAM 6D Camera Operation Training September 2012 CoroCAM 6D Body Rubber cover on SD Card slot & USB port Lens Cap retention loop Charging port, video & audio output, audio input Laser pointer CoroCAM

More information

CHECKMATE REFERENCE MANUAL

CHECKMATE REFERENCE MANUAL Serial Number CHECKMATE REFERENCE MANUAL CHECKMATE Instrument CORROSOMETER Probes Rohrback Cosasco Systems, Inc. 11841 East Smith Avenue Santa Fe Springs, CA 90670 Tel: +1 (562) 949-0123 Fax: +1 (562)

More information

Excel Tool: Plots of Data Sets

Excel Tool: Plots of Data Sets Excel Tool: Plots of Data Sets Excel makes it very easy for the scientist to visualize a data set. In this assignment, we learn how to produce various plots of data sets. Open a new Excel workbook, and

More information

Linkam Scientific Instruments USER GUIDE

Linkam Scientific Instruments USER GUIDE Linkam Scientific Instruments Linksys32 Temperature Control and Video Capture Software USER GUIDE Contents Introduction.... 3 Product Registration... 3 Feedback...3 Linksys32 Overview... 3 Software Activation...

More information

LAB I. INTRODUCTION TO LAB EQUIPMENT

LAB I. INTRODUCTION TO LAB EQUIPMENT LAB I. INTRODUCTION TO LAB EQUIPMENT 1. OBJECTIVE In this lab you will learn how to properly operate the basic bench equipment used for characterizing active devices: 1. Oscilloscope (Keysight DSOX 1102A),

More information

EE354 Spring 2016 Lab 1: Introduction to Lab Equipment

EE354 Spring 2016 Lab 1: Introduction to Lab Equipment Name: EE354 Spring 2016 Lab 1: Introduction to Lab Equipment In this lab, you will be refreshed on how MATLAB and the lab hardware can be used to view both the time-domain and frequency-domain version

More information

SonoLab Echo-I User Manual

SonoLab Echo-I User Manual SonoLab Echo-I User Manual Overview: SonoLab Echo-I is a single board digital ultrasound pulse-echo solution. The system has a built in 50 volt high voltage generation circuit, a bipolar pulser, a transmit/receive

More information

Direct waveform transfer from a DS1000Z scope to a DG4000 generator

Direct waveform transfer from a DS1000Z scope to a DG4000 generator Direct waveform transfer from a DS1000Z scope to a DG4000 generator Last Updated: Jan 14, 2016 05:25PM PST Direct Waveform Transfer from Scope to Generator The advent of digital storage oscilloscopes and

More information

Introduction to QTO. Objectives of QTO. Getting Started. Requirements. Creating a Bill of Quantities. Updating an existing Bill of Quantities

Introduction to QTO. Objectives of QTO. Getting Started. Requirements. Creating a Bill of Quantities. Updating an existing Bill of Quantities QTO User Manual Contents Introduction to QTO... 5 Objectives of QTO... 5 Getting Started... 5 QTO Manager... 6 QTO Layout... 7 Bill of Quantities... 8 Measure Folders... 9 Drawings... 10 Zooming and Scrolling...

More information

University of Utah Electrical & Computer Engineering Department ECE 2210/2200 Lab 4 Oscilloscope

University of Utah Electrical & Computer Engineering Department ECE 2210/2200 Lab 4 Oscilloscope University of Utah Electrical & Computer Engineering Department ECE 2210/2200 Lab 4 Oscilloscope Objectives 1 Introduce the Oscilloscope and learn some uses. 2 Observe Audio signals. 3 Introduce the Signal

More information

Parts to be supplied by the student: Breadboard and wires IRLZ34N N-channel enhancement-mode power MOSFET transistor

Parts to be supplied by the student: Breadboard and wires IRLZ34N N-channel enhancement-mode power MOSFET transistor University of Utah Electrical & Computer Engineering Department ECE 1250 Lab 3 Electronic Speed Control and Pulse Width Modulation A. Stolp, 12/31/12 Rev. Objectives 1 Introduce the Oscilloscope and learn

More information

Ansoft Designer Tutorial ECE 584 October, 2004

Ansoft Designer Tutorial ECE 584 October, 2004 Ansoft Designer Tutorial ECE 584 October, 2004 This tutorial will serve as an introduction to the Ansoft Designer Microwave CAD package by stepping through a simple design problem. Please note that there

More information

Mach 5 User s Manual Revision 2.2 1

Mach 5 User s Manual Revision 2.2 1 1 2 WARRANTY The Gentec-EO MACH 5 Meter carries a one-year warranty (from date of shipment) against material and/or workmanship defects, when used under normal operating conditions. The warranty does not

More information

Exercise 4. Angle Tracking Techniques EXERCISE OBJECTIVE

Exercise 4. Angle Tracking Techniques EXERCISE OBJECTIVE Exercise 4 Angle Tracking Techniques EXERCISE OBJECTIVE When you have completed this exercise, you will be familiar with the principles of the following angle tracking techniques: lobe switching, conical

More information

SoundCheck 12.0 Quick Start Guide

SoundCheck 12.0 Quick Start Guide Software Install Basics Upgrading From an Earlier Version If you are upgrading from an earlier version of SoundCheck 12.0 (or Beta version) you should copy the old installation folder and name it "SoundCheck

More information

APPLICATION NOTE Getting Started with EasySpectrum Software

APPLICATION NOTE Getting Started with EasySpectrum Software APPLICATION NOTE Getting Started with EasySpectrum Software INTRODUCTION: EasySpectrum software provides a remote control interface for SIGLENT SSA3000 Series of spectrum analyzers that can be used to

More information

AxoGraph X Data Acquisition Manual

AxoGraph X Data Acquisition Manual AxoGraph X Data Acquisition Manual PLEASE NOTE: For the best figure quality when reading this document onscreen, the zoom setting should be 147 %. If the zoom setting has changed, type 147 % into the zoom

More information

Head Tracker Range Checking

Head Tracker Range Checking Head Tracker Range Checking System Components Haptic Arm IR Transmitter Transmitter Screen Keyboard & Mouse 3D Glasses Remote Control Logitech Hardware Haptic Arm Power Supply Stand By button Procedure

More information

About the DSR Dropout, Surge, Ripple Simulator and AC/DC Voltage Source

About the DSR Dropout, Surge, Ripple Simulator and AC/DC Voltage Source About the DSR 100-15 Dropout, Surge, Ripple Simulator and AC/DC Voltage Source Congratulations on your purchase of a DSR 100-15 AE Techron dropout, surge, ripple simulator and AC/DC voltage source. The

More information

JD723A/JD724B/JD726A Cable and Antenna Analyzers

JD723A/JD724B/JD726A Cable and Antenna Analyzers COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS JD723A/JD724B/JD726A Cable and Antenna Analyzers Key Features Portable and lightweight handheld instrument. Built in wireless frequency bands as well as the

More information

Residual Gas Analyzers XT Series

Residual Gas Analyzers XT Series Residual Gas Analyzers XT Series Products from ExTorr Inc. - Pirani, Ion Gauge, Quadrupole - All Included The Extorr XT residual gas analyzer is a quadrupole mass spectrometer complete with a built-in

More information

Rotary Knife. [System Configuration] [Operation Overview] [Points of Control] Cutter Axis. Virtual Sheet Feed Amount Axis 1 BCN-B A

Rotary Knife. [System Configuration] [Operation Overview] [Points of Control] Cutter Axis. Virtual Sheet Feed Amount Axis 1 BCN-B A Rotary Knife [System Configuration] Mark Sensor Cutter Axis Conveyor Axis Axis 1 Axis 2 [Mitsubishi solution] PLC CPU: Q06UDEHCPU Simple Motion module: QD77MS4 Main base: Q35DB Servo amplifier: MR-J4-B

More information

AE Agricultural Customer Services Play-by-Play Tekscope Manual

AE Agricultural Customer Services Play-by-Play Tekscope Manual 1 2012 AE Agricultural Customer Services Play-by-Play Tekscope Manual TABLE OF CONTENTS I. Definitions II. Waveform Properties 1 III. Scientific Notation... 2 IV. Transient Levels of Concern a. ASAE Paper

More information