Operator Manual 1.4 FRACSIM MINI

Size: px
Start display at page:

Download "Operator Manual 1.4 FRACSIM MINI"

Transcription

1 FracSim Meters FracSim Meters was founded with the intention of providing specifically designed tools for the well service industry. Our goal is to provide quality tools with a robust design to meet the needs of well service technicians. If you Operator Manual 1.4 FRACSIM MINI have any questions or concerns please contact us at: FracSim Meters Grande prairie Alberta (780) or For additional information on different products or instructional videos on how to use the FracSim meter please visit the website. 2

2 Table of Contents FracSim Meters... 2 Specifications: Specifications:... 4 Selecting and using batteries:... 5 Cold weather operation:... 5 Warnings:... 6 Using this manual:... 7 Using the interface turn knob:... 7 Main Menu:... 8 Voltage Measure:... 9 Current Measure:... 9 Continuity Measure:... 9 Diode Measure: Frequency Measure: Scope View: Current Simulate Functions: Frequency Simulation Function: Serial Data Functions: Settings Menu:

3 Selecting and using batteries: The FracSim meter uses a switching power supply and can accept battery voltages from 6.5 to 20 volts. The higher the voltage, the less current it draws due to the switching power supply. Using the supplied battery holder you can use 2 X 9V. Alkaline batteries work but can be substituted with "9V"rechargeable batteries. The battery voltage is momentarily displayed when the meter powers up. The Battery voltage dictates the maximum voltage on frequency simulate and current sourcing modes. Warnings: Do not open the case: Opening the case beyond the battery compartment will void warranty. There are no user serviceable parts. The current measure has 130 ohm s resistance with a PTC and cannot be damaged even with a dead short (maximum 30 volts). To open the battery compartment remove the 4 screws on the bottom of the meter. This will release the battery cover. Disconnect the connectors on the top of the batteries to remove them from the meter. Avoid contacting the battery pack connector terminals incorrectly with the battery pack terminals (reverse polarity). This has been tested and does not cause immediate damage but is not recommended. Cold weather operation: In colder weather (less than 0 C), the meter should be powered up inside before being exposed to the colder weather. The FracSim meter is calibrated at 22 C, the highest level of accuracy is at 22 C (the temperature where it was calibrated at). Fail Safe Contrast boot: If the meter's displays contrast is far out of adjustment you can power up the meter in a special mode to set the contrast. Follow these steps: Power on the meter by pressing the button but continue to hold down the button. The meter will beep a pulse beep for about 7 seconds. when the beep turns into a continuous tone release the button. the meter will now change contrast slowly. When the text becomes clearly visible press the button again to set 30 VDC MAX. NOT INTRINSICALLY SAFE. DO NOT APPLY THE CURRENT SOURCE OUTPUT OF THE FRACSIM METER TO THE GND OF ANOTHER VOLTAGE SUPPLY, THIS MAY GENERATE A HIGHER VOLTAGE DUE TO THE SERIES EFFECT AND DAMMAGE THE FRACSIM METER. BE AWARE OF THE ACCURACY SPECIFICATIONS OF THIS DEVICE. PLEASE REFERENCE THE SPECS AND MAKE SURE THEY ARE WITHIN YOUR TOLERANCE. 5 6

4 Using this manual: Main Menu: When using the manual please note the following: This icon marks all the pin outs for each function. All measurement function use the "Red Socket" (positive)" and "Black socket"(negative)" This icon marks important operation functionality. Please keep these in mind when using the FracSim MEAS<= V DC To measure voltage / mv DC ma To measure ma Hz To measure frequency / scope view Ω To measure continuity DIODE To measure voltage drop across a diode Using the interface turn knob: To become efficient and fast at managing the meter you should take a few minutes to learn the correct interface turn knob usage. The turn knob is a rotary encoder. By turning it left and right you can scroll through different menus and adjust variable set points. By pressing the turn knob down you can; power the meter off and on, select menu items and exit from menus. Pressing the turn knob down and holding for 1 second will power the meter on. Pressing the turn knob down and holding for 2 seconds will power off power off. Pressing the turn knob down and holding between 1 and 2 seconds causes the meter to exit the current mode SIM=> ma To sink or source current Hz output a frequency signal RS 485 DAT<= To read incoming RS485 DAT=> To output RS485 SETTING CONTRAS To adjust screen contrast BACKLT To change backlight timer AUTOPW To change auto power off timer CALMODE for factory trained techs 7 8

5 Voltage Measure: The FracSim meter will measure -30V to 30 V DC. To access voltage measure mode from the main menu select MEAS<= and V DC. Pressing the turn knob down quickly will change the range to mv to 1500 mv and back Current Measure: Diode Measure: The FracSim meter will measure voltage drop across a diode. To access diode measure mode from the main menu select MEAS<= and DIODE. Red socket to anode of diode Black socket to cathode of diode The FracSim meter will measure -21mA to 21mA. To access current measure mode from the main menu select MEAS<= and ma. The current measurement circuit does not employ a traditional fuse for protection. Current limiting is accomplished by utilizing a relatively high internal resistance, 100 ohms. The current measure was designed for use on current loops and in most situations this load is fine. Just be aware of its limitations. If the FracSim is exposed to a dead short on current measure the internal PTC will open up however some current will still flow and the display will flash OL. Continuity Measure: The FracSim meter will measure continuity. An audio and visual feedback will trigger at approximately 50Ω To access continuity measure mode from the main menu select MEAS<= and Ω. Frequency Measure: The FracSim meter can measure frequency from 1 to to 30 volts AC/DC. To access frequency measure from the main menu select MEAS<= and Hz. The measure frequency function also displays the duty cycle, and Min and Max peak values. Pressing the turn knob down quickly will change the meter to Scope view Scope View: Once inside the frequency measure mode pressing the turn knob quickly will enter the Scope View mode. The Scope View mode display a visual representation of the frequency signal. The time base and voltage level is auto ranging. 9 10

6 Current Simulate Functions: The FracSim meter can sink or source 0 up to 22mA while simultaneously measuring loop voltage. To access the current simulation from the main menu select SIM=> and ma. Use the following pin outs: Sinking: - Supply volts from equipment to red socket on meter - Black socket to signal input of equipment Sourcing: - Red socket to signal input of equipment - Frame ground to black socket on meter As previously stated the current simulation also shows the measured loop voltage for quick loop diagnostics. The loop voltage function is only useful while sinking current. Most transmitters require a minimum 8 to 10 volts. So if you see a loop voltage lower than this or the transmitters recommended voltage minimum, then this is an issue. The FracSim meter will work because it is internally powered but the transmitter may not Pressing the turn knob down quickly will increment the output value by 4mA each press Turning the turn knob clockwise will increment the output value by 0.1mA Turning the turn knob counter-clockwise will decrement the output value by 0.1mA Frequency Simulation Function: The FracSim meter will simulate an AC / DC square wave frequency from 1 to 5000 Hz with a range from 0 to 18 volts (maximum is proportional to battery voltage). To access the frequency simulation from the main menu select SIM=> and Hz. Use the following pin outs: Adjustments: Red socket to device input Black socket to device ground Default output is 18V (battery voltage) DC coupled at 100 Hz Turning the knob will increment / decrement the frequency output Pressing the turn knob down quickly will enter an adjustment sub menu First Select AC or DC for the correct type of coupling Second turn the knob left and right to adjust the voltage level For devices that have a very low level switching point use the AC mode. An example of a low level input could be the Red Lion silver tube amplifiers (Part: ASTC0000)

7 Serial Data Functions: The FracSim meter can read and write RS 485 ASCII 9600, 19200, 38400, The data output can either by in WITS or CSV format. Every time data is received the FracSim will beep. To access frequency measure from the main menu select RS485. Red socket to RS485 "A" Black socket to RS485 "B" There are several serial data modes here is basic list of when to use each: DAT <=, RAW- use when you need read generic ASCII data. DAT <=, COMPANY SPECIFIC- use when you need read application specific data. DAT =>, CSV- use when you need output CSV format ASCII data. DAT =>, COMPANY SPECIFIC- use when you need to output application specific data. DAT =>, CSV Select the baud rate. The screen will display the same data that is being outputted. The first digit of each value is the channel number. The two decimal places are random numbers. Example data burst: 1.45,2.67,3.83, DAT =>, COMPANY SPECIFIC The baud rate and format is pre determined. The data output is application specific. The display shows the data output with the channel names. Pressing the turn knob down will change the display format to show raw data. Settings Menu: Inside the settings menu you can: Adjust the contrast Adjust the auto Backlight off, units are in seconds Adjust the auto power off, units are in minutes DAT <=, RAW Select the baud rate. Once inside the data window you will see incoming data. If you see "waiting on data" it means no valid data has been received. The maximum input is 500 characters per data burst. Turn the turn knob to scroll through the data buffer. DAT <=, COMPANY SPECIFIC The baud rate and format is pre determined. The data input is application specific. The display shows the data input with the corresponding channel names. Turning the turn knob will scroll through all the data available

Not for Reproduction

Not for Reproduction 1 ADVANCE PRODUCT SERVICE INFORMATION SUBJECT: OPERATING PROCEDURES FOR EXTECH DIGITAL MULTIMETER No: #66 DATE: 05/31/2010 MODELS: 19602 DIGITAL MULTIMETER A digital multimeter is necessary for electrical

More information

Process Calibrator. TechChek 820

Process Calibrator. TechChek 820 Process Calibrator TechChek 80 CONTENTS GENERAL... TURN ON... CONNECTIONS... TILT STAND...4 CHANGING BATTERIES...4 RESTORING DEFAULT SETTINGS... CONFIGURING TEMPERATURE SCALES... ENABLING AUTO-OFF... SELECTING

More information

Model 422 Diagnostic Thermocouple & Milliamp Calibrator Operating Instructions

Model 422 Diagnostic Thermocouple & Milliamp Calibrator Operating Instructions Model 422 Diagnostic Thermocouple & Milliamp Calibrator Operating Instructions Two Calibrators in One! Calibrate all your thermocouple instruments AND your milliamp loops with the PIE 422Plus. It has all

More information

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free User s Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 400A AC/DC Clamp Meter Model MA220 Introduction Thank you for selecting

More information

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle. INSTRUCTION MANUAL Model 403380 Autoranging DMM ProbeMeter TM Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle. Back lit LCD with Autorange and full function displays Audible

More information

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology ENGLISH INSTRUCTION MANUAL 2000A Digital Clamp Meter True RMS Measurement Technology NON-CONTACT VOLTAGE TESTING INRUSH CURRENT LOW IMPEDANCE DATA HOLD RANGE HOLD AUDIBLE CONTINUITY DIODE TEST CAPACITANCE

More information

User s Guide. 400A AC/DC Clamp Meter. Model MA220

User s Guide. 400A AC/DC Clamp Meter. Model MA220 User s Guide 400A AC/DC Clamp Meter Model MA220 Introduction Thank you for selecting the Extech MA200 AC/DC Clamp Meter. This meter measures AC/DC Current, AC/DC Voltage, Resistance, Capacitance, Frequency,

More information

Digital MultiMeter - Make your job efficiency User Instruction Manual

Digital MultiMeter - Make your job efficiency User Instruction Manual Digital MultiMeter - Make your job efficiency User Instruction Manual Main Fields of Application: Process industries, Metallurgy, Power generation, Research, Laboratories, Maintenance, After sales service,

More information

AX-C Introduction. 2. Safety Information

AX-C Introduction. 2. Safety Information AX-C708 1. Introduction Read Safety Information before using the meter. ProcessMeter ( referred to as the meter )is a handheld, battery-operated tool for measuring electrical parameters. It has all the

More information

PIE 525. Diagnostic Thermocouple RTD & Milliamp Calibrator Operating Instructions. Practical Instrument Electronics

PIE 525. Diagnostic Thermocouple RTD & Milliamp Calibrator Operating Instructions. Practical Instrument Electronics PIE 525 Diagnostic Thermocouple RTD & Milliamp Calibrator Operating Instructions Practical Instrument Electronics Tel: 585.872.9350 Fax: 585.872.2638 sales@piecal.com www.piecal.com Contents General Operations

More information

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

USER MANUAL 600A AC Clamp Meter + NCV Model MA610 USER MANUAL 600A AC Clamp Meter + NCV Model MA610 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech MA610 Clamp Meter. This meter measures

More information

WRM-10 TM TRANSFORMER WINDING RESISTANCE METER

WRM-10 TM TRANSFORMER WINDING RESISTANCE METER WRM-10 TM TRANSFORMER WINDING RESISTANCE METER USER S MANUAL Vanguard Instruments Company, Inc. 1520 S. Hellman Ave. Ontario, California 91761, USA TEL: (909) 923-9390 FAX: (909) 923-9391 June 2009 Revision

More information

Dawson DDM190. Digital Multimeter User s Manual

Dawson DDM190. Digital Multimeter User s Manual Dawson DDM190 Digital Multimeter User s Manual TABLE OF CONTENTS LIMITED WARRANTY AND LIMITATION OF LIABILITY... 3 Out of the Box... 3 Accessories.. Error! Bookmark not defined. Safety Information... 7

More information

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature USER GUIDE True RMS Digital Multimeters EX350 Series EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature Table of Contents 1. INTRODUCTION 3 2. SAFETY INFORMATION 4 3.

More information

Agilent U1273A/U1273AX Handheld Digital Multimeter. Quick Start Guide

Agilent U1273A/U1273AX Handheld Digital Multimeter. Quick Start Guide Agilent U1273A/U1273AX Handheld Digital Multimeter Quick Start Guide Verify that you received the following items in the shipment of your multimeter: One pair of red and black test leads One pair of 4

More information

TT-2Dx USER'S MANUAL

TT-2Dx USER'S MANUAL ELECTRONIC DEVICES INC. P.O. BOX 15037, CHESAPEAKE, VA 23328 PHONE (757) 421-2968 FAX (757) 421-0518 TT-2Dx USER'S MANUAL 1. INTRODUCTION 2. CONTROL FUNCTIONS 3. GETTING STARTED 4. HOW IT WORKS 5. CALIBRATION

More information

LV8716QAGEVK Evaluation Kit User Guide

LV8716QAGEVK Evaluation Kit User Guide LV8716QAGEVK Evaluation Kit User Guide NOTICE TO CUSTOMERS The LV8716QA Evaluation Kit is intended to be used for ENGINEERING DEVELOPMENT, DEMONSTRATION OR EVALUATION PURPOSES ONLY and is not considered

More information

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual Dawson DDM230C True RMS Multimeter with Bar Graph Display User s Manual Table of Contents LIMITED WARRANTY AND LIMITATION OF LIABILITY... 3 Out of the Box... 3 Accessories... 4 Safety Information... 4

More information

DCM730. Digital Clamp Meter User s Manual

DCM730. Digital Clamp Meter User s Manual DCM730 Digital Clamp Meter User s Manual Table of Contents LIMITED WARRANTY AND LIMITATION OF LIABILITY...1 Out of the Box...1 Safety Information...2 INTRODUCTION...4 Components and Buttons...6 Names of

More information

DVM1190 DIGITAL MULTIMETER

DVM1190 DIGITAL MULTIMETER DIGITAL MULTIMETER 1. Introduction Thank you for buying the. This digital multimeter has a large LCD, a data-hold function and a backlight. The device uses a very practical safety mechanism that keeps

More information

10 Amperes max. test current Micro-Ohm Meter Model : MO-2014 OPERATION MANUAL

10 Amperes max. test current Micro-Ohm Meter Model : MO-2014 OPERATION MANUAL 10 Amperes max. test current Micro-Ohm Meter Model : MO-2014 Your purchase of this Micro-Ohm METER marks a step forward for you into the field of p r e c i s i o n measurement. Although this Micro-Ohm

More information

DIGITAL MULTIMETER AUTORANGING

DIGITAL MULTIMETER AUTORANGING MODEL: D03124 DIGITAL MULTIMETER AUTORANGING 1 CONTENTS Page Number Details 2 Introduction 2 What s Included 3 Important Safety Information 3 Symbol Guide 4 Overview 5 Buttons 5 Display Indicators 6 General

More information

Digital Multimeter, Pen Type

Digital Multimeter, Pen Type MODEL: D03127 Digital Multimeter, Pen Type 1 CONTENTS Page Number Description 3 Important Safety Information 3 Electrical Symbols 4 Overview 4 Measurement Operation 5 AC & DC Voltage Measurement 5 AC &

More information

7006 Loop Mate 1 Loop / Voltage / Current Simulator

7006 Loop Mate 1 Loop / Voltage / Current Simulator 7006 Loop Mate 1 Loop / Voltage / Current Simulator User Manual Time Electronics Ltd Unit 11 Botany Industrial Estate Tonbridge, Kent, TN9 1RH Tel: 01732 355993 Fax: 01732 770312 E-Mail: mail@timeelectronics.co.uk

More information

VC835 DIGTAL MULTIMETER Operation Manual

VC835 DIGTAL MULTIMETER Operation Manual VC835 DIGTAL MULTIMETER Operation Manual CONTENTS GENERAL DESCRIPTION Safety Instructions FEATURES OPERATION MAINTENANCE TROUBLE SHOOTING 1. General Description This is a 3 1/2 digital multimeter with

More information

AF10 PWM Generator. Manual. Valid as of firmware version v1.4.1

AF10 PWM Generator. Manual. Valid as of firmware version v1.4.1 AF10 PWM Generator Manual Valid as of firmware version v1.4.1 1 AF10 PWM Generator Manual Contents 1 Controls... 4 1.1 Main switch (back)... 4 1.2 ON button... 4 1.3 Esc button... 4 1.4 Setup button...

More information

USER'S MANUAL DMR-6700

USER'S MANUAL DMR-6700 USER'S MANUAL Multimeter True RMS DMR-6700 CIRCUIT-TEST ELECTRONICS www.circuittest.com Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),

More information

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC USER MANUAL True RMS Digital Multimeters EX360 Series EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC EX365 True RMS DMM with 10A AC/DC Current Additional User Manual

More information

Pocket Size Digital Multimeter with USB Model: A & A

Pocket Size Digital Multimeter with USB Model: A & A Pocket Size Digital Multimeter with USB Model: 72-7730A & 72-7732A 1 IMPORTANT SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This instrument is

More information

NOTE: Fully read and understand this manual before using this Digital Multimeter.

NOTE: Fully read and understand this manual before using this Digital Multimeter. ASTROAI USER MANUAL AUTO RANGING DIGITAL CLAMP METER Thank you for purchasing the Auto Ranging Digital Clamp Meter from AstroAI. The AstroAI Auto Ranging Digital Clamp Meter is designed to be safely and

More information

Model 532 ma/v Loop Calibrator with Loop Diagnostic Operating Instructions

Model 532 ma/v Loop Calibrator with Loop Diagnostic Operating Instructions Practical Instrument Electronics Model 532 ma/v Loop Calibrator with Loop Diagnostic Operating Instructions A. Basic Keypad Operations j EZ-Check Switch/EZ-Step Pushbutton Slide the switch to select the

More information

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 800 Amp AC/DC True RMS Clamp Meter Model EX730 Introduction Congratulations

More information

PIECAL 211 Automated RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

PIECAL 211 Automated RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics Product Description Easy to use With the PIECAL 211 you can check & calibrate all your RTD instruments and measure RTD Sensors. Automatic indication of connections on the display for simple hookups. Take

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-340 MODEL: 61-342 Multimeter Service Information The Service Information provides the following information: Precautions and safety information Specifications

More information

Agilent U1271A/U1272A Handheld Digital Multimeter. Quick Start Guide

Agilent U1271A/U1272A Handheld Digital Multimeter. Quick Start Guide Agilent U1271A/U1272A Handheld Digital Multimeter Quick Start Guide Verify that you received the following items in the shipment of your multimeter: One pair of red and black test leads One pair of 4 mm

More information

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE INSTRUCTION MANUAL Auto-Ranging Digital Multimeter MM400 DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE 600V 10A 40MΩ 2 GENERAL SPECIFICATIONS Klein Tools MM400 is an auto-ranging

More information

User Manual Digital Multimeter

User Manual Digital Multimeter User Manual Digital Multimeter model no.: MSR-R500 Questions or Concerns? support@etekcity.com visit etekcity.com for more products Safe and Proper Usage Thank you for purchasing the Etekcity MSR-R500

More information

KMD-S04 Multímetro de bolsillo

KMD-S04 Multímetro de bolsillo www.grupotemper.com KMD-S04 Multímetro de bolsillo Table of Contents Title Page Overview ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ 3 Unpacking Inspection ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ 4 Safety Information

More information

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS CONTENTS CONTENTS CONTENTS 1. SAFETY INFORMATION...1 1.1 Preliminary...1 1.2 Dos and don ts...2 1.3 Symbols...3 1.4 Precautions...4 2. DESCRIPTION...5 2.1 Names of parts...6 2.2 Switches, buttons and input

More information

PIECAL 820 Multifunction Process Calibrator

PIECAL 820 Multifunction Process Calibrator PIECAL 820 Multifunction Process Calibrator ma V TC Hz Operating Instructions 99 Washington Street Melrose, MA 02176 800.517.8431 TestEquipmentDepot.com Contents General Operations Field & Bench Use, Changing

More information

PIECAL 311 Automated Universal RTD Calibrator Operating Instructions. Product Description

PIECAL 311 Automated Universal RTD Calibrator Operating Instructions. Product Description Product Description Easy to use With the PIECAL 311 you can check & calibrate all your RTD instruments and measure RTD Sensors. Automatic indication of connections on the display for simple hookups. Take

More information

MS2109A AC/DC Clamp Meter. User Manual. Contents

MS2109A AC/DC Clamp Meter. User Manual. Contents MS2109A AC/DC Clamp Meter User Manual Contents 1. Safety information 1 1.1 Preparation 1 1.2 Usage 1 1.3 Signs and Labels 2 1.4 Maintenance 2 2. Description 2 2.1 Part name 3 2.2 Switch and button description

More information

Agilent U1253B True RMS OLED Multimeter. Quick Start Guide

Agilent U1253B True RMS OLED Multimeter. Quick Start Guide Agilent U1253B True RMS OLED Multimeter Quick Start Guide The following items are included with your multimeter: Silicone test leads 4 mm probes Alligator clips Printed Quick Start Guide Rechargeable 8.4

More information

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology INSTRUCTION MANUAL Auto-Ranging Digital Multimeter er True RMS Measurement Technology MM700 DATA & RANGE HOLD LOW IMPEDANCE AUDIBLE CONTINUITY MIN / MAX / RELATIVE TEMPERATURE DIODE TEST CAPACITANCE &

More information

INSTRUCTION MANUAL DIGITAL MULTIMETER

INSTRUCTION MANUAL DIGITAL MULTIMETER INSTRUCTION MANUAL DIGITAL MULTIMETER 600 OFF 600 20 2m 2 20m m m 2M 10A k 20k 2k O C NPN PNP hfe E B C E 10A DC 10A MAX UNFUSED MAX 600V COM V ma ma MAX FUSED CAT II 600V Thanks for buying our products,

More information

Meriam Model M ma Loop Calibrator Operating Instructions

Meriam Model M ma Loop Calibrator Operating Instructions process technologies Meriam Model 4-20 Operating Instructions Product Description EASY TO USE With the Meriam Model you can check, calibrate and measure all your current signal instruments in a 4 to 20

More information

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com Model ST-9933 True RMS Autoranging Digital Multimeter Instruction Manual reedinstruments com Table of Contents Safety... 3 Features... 4 Specifications...4-8 Technical...4-5 Accuracy...5-8 Display Description...

More information

Multifunction Digital

Multifunction Digital MS2009A Multifunction Digital Clamp Meter User Manual 200/600 OFF 2/20 NCV SEL MAX V RAN HOLD OFF MS2009A AC CLAMP METER AUTO MAX C F kmω μmva CONTENTS Safety requirements...1 Safety signs...1 Notes...1

More information

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at ASTROAI USER MANUAL DT132A 4000 Count Auto-Ranging Multimeter Thank you for purchasing the AstroAI DT132A 4000 Count Auto-Ranging Multimeter. It is a 3 ¾ digit, 3999 counts, auto-ranging digital multimeter.

More information

TOP SERVO SIGNAL 5 SERVO SIGNAL 3 SERVO SIGNAL 4 SERVO SIGNAL 6 T B T B T B T B T B SERVO TRIGGER 1 BOTTOM

TOP SERVO SIGNAL 5 SERVO SIGNAL 3 SERVO SIGNAL 4 SERVO SIGNAL 6 T B T B T B T B T B SERVO TRIGGER 1 BOTTOM Micro Miniatures Servo Controller Channel Location of connections and switches TOP SERVO SIGNAL SERVO SIGNAL 7 SERVO SIGNAL 6 SERVO SIGNAL 5 SERVO SIGNAL SERVO SIGNAL SERVO SIGNAL SERVO SIGNAL SIGNAL COMMON

More information

Fluke 125. Getting Started. Industrial ScopeMeter

Fluke 125. Getting Started. Industrial ScopeMeter Fluke 125 Industrial ScopeMeter Getting Started GB Dec 2006, Rev. 1, 09/2009 2006, 2009 Fluke Corporation, All rights reserved. Printed in The Netherlands All product names are trademarks of their respective

More information

MW3105 DIGITAL CLAMP MULTIMETER

MW3105 DIGITAL CLAMP MULTIMETER MW3105 DIGITAL CLAMP MULTIMETER 2 M MW3105 A 01 INTRODUCTION 1.1 - Unpacking and inspection Upon removing your new Digital Clamp Meter from its packing, you should have the following items: 1. Digital

More information

PIECAL 311 Automated Universal RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

PIECAL 311 Automated Universal RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics Product Description Easy to use With the PIECAL 311 you can check & calibrate all your RTD instruments and measure RTD Sensors. Automatic indication of connections on the display for simple hookups. Take

More information

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español Owner's Manual AC/DC Clamp Meter Model No. 82369 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance Español

More information

PROCESS & TEMPERATURE CONTROLLERS

PROCESS & TEMPERATURE CONTROLLERS PROCESS & TEMPERATURE CONTROLLERS NOVA PD54 Series Thermocouple, RTD, & Process Inputs High Accuracy Auto-Tuning PID Heating & Cooling Models Universal Power Supply 1-24 VAC Up to 3 Relays & 2 Analog Outputs

More information

Resonance indicator LEDº. » Transducer connection. Button B º. » LCD display. Power/fine frequency º. frequency set

Resonance indicator LEDº. » Transducer connection. Button B º. » LCD display. Power/fine frequency º. frequency set July 2001 4502 TT-2D USERS MANUAL 1. INTRODUCTION 2. CONTROL FUNCTIONS 3. GETTING STARTED 4. HOW IT WORKS 5. CALIBRATION 6. BATTERY TEST 7. SPECIFICATIONS 8. WARRANTY AND REPAIR INFORMATION 9. COMMONLY

More information

Model: &

Model: & 600A True RMS Digital Clamp Meter Model: 72-3097 & 72-3099 1 CONTENTS Page Number Details 3 Important Safety Information 4 Product overview 4 Key Functions 5 General Specification 5 Electrical Specification

More information

HP 33120A Function Generator / Arbitrary Waveform Generator

HP 33120A Function Generator / Arbitrary Waveform Generator Note: Unless otherwise indicated, this manual applies to all Serial Numbers. The HP 33120A is a high-performance 15 MHz synthesized function generator with built-in arbitrary waveform capability. Its combination

More information

MODEL: D03128 CLAMP METER

MODEL: D03128 CLAMP METER MODEL: D03128 CLAMP METER 1 CONTENTS Page Number Details 3 Important Safety Information 3 Features 4 Product Overview 5 Switches, Buttons & Input Jacks 5 LCD 6 Specifications 6 Electrical Specifications

More information

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

AC/DC DIGITAL CLAMP METER OPERATION MANUAL AC/DC DIGITAL CLAMP METER OPERATION MANUAL HYS005661 A0 ACCESSORIES 6. ACCESSORIES 1) Test Leads: Electric Ratings 1000V 10A 1 pair (set) 2) Operating Manual 1 copy 3) 1.5V AAA Battery 3 piece - - 55 -

More information

MULTIMETER TRAINING UNIT QUICKSTART GUIDE

MULTIMETER TRAINING UNIT QUICKSTART GUIDE MULTIMETER TRAINING UNIT QUICKSTART GUIDE MULTIMETER TRAINING UNIT 1 MULTIMETER TRAINING UNIT CONTENTS General Information... 2 Battery... 3 Voltage Drop... 4 Alternator... 5 Frequency... 6 Millivolts...

More information

Digital Multimeter User Manual

Digital Multimeter User Manual Digital Multimeter User Manual B35(T) D35(T) Note: "T" indicates true RMS (optional) Table of Contents 1.Safety Information... 1 Safety Considerations... 1 Measurement Category... 3 Safety Terms and Symbols...

More information

B & D Enterprises 1P repeater controller pg 1 INTRODUCTION:

B & D Enterprises 1P repeater controller pg 1 INTRODUCTION: B & D Enterprises 1P repeater controller pg 1 INTRODUCTION: The 1P is a basic repeater controller. The controller uses low power devices and stores all commands and system status in non-volatile EE prom.

More information

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS Measurement Technology MM700 DATA & RANGE HOLD LOW IMPEDANCE AUDIBLE CONTINUITY MIN / MAX / RELATIVE TEMPERATURE DIODE TEST CAPACITANCE & FREQUENCY

More information

User Manual Digital Multimeter. model no.: MSR-U1000

User Manual Digital Multimeter. model no.: MSR-U1000 User Manual Digital Multimeter model no.: MSR-U1000 This Operating Manual covers information on safety and cautions. Please read the relevant information carefully and observe all the Warnings and Notes

More information

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV. MS8250A/B DIGITAL MULTIMETER OPERATION MANUAL AUTO DC AC REL hfe PCLINK % C F kmωkz nµmfav MS8250A DIGITAL MULTIMETER Auto Power Off RANGE REL HOLD FUNC NCV A ma OFF 10A A ma 10A FUSED 600V CAT IV COM

More information

MFJ-249B HF/VHF SWR ANALYZER

MFJ-249B HF/VHF SWR ANALYZER TABLE OF CONTENTS MFJ-249B... 2 Introduction... 2 Powering The MFJ-249B... 3 Battery Installation... 3 Alkaline Batteries... 3 NiCd Batteries... 4 Power Saving Mode... 4 Operation Of The MFJ-249B...5 SWR

More information

Micro-Ohmmeter Model UM200

Micro-Ohmmeter Model UM200 User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Micro-Ohmmeter Model UM200 WARNING Do not use the ohmmeter before

More information

GE Infrastructure Sensing. Druck DPI 841/842. Frequency calibrator and Frequency loop calibrator User manual - K395

GE Infrastructure Sensing. Druck DPI 841/842. Frequency calibrator and Frequency loop calibrator User manual - K395 GE Infrastructure Sensing Druck DPI 841/842 Frequency calibrator and Frequency loop calibrator User manual - K395 A1 B1 10 1 A 2 9 A 3 8 2 3 7 6 11 4 5 B1 12 A2 DPI 842 13 15 14 A3 19 18 17 16 27 20 21

More information

Digital Clamp Meter Model: &

Digital Clamp Meter Model: & Digital Clamp Meter Model: 72-7224 & 72-7226 1 SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This meter is designed to meet IEC61010-1, 61010-2-032,

More information

PIECAL 211 Automated Universal RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

PIECAL 211 Automated Universal RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics Product Description Easy to use With the PIECAL 211 you can check & calibrate all your RTD instruments and measure RTD Sensors. Automatic indication of connections on the display for simple hookups. Take

More information

Jet Central Sequencer Plus

Jet Central Sequencer Plus Jet Central Sequencer Plus Features The Jet Central Sequencer Plus is a multipurpose electronic device, the capabilities of the unit include: Three part sequencer, operating landing gear and two independent

More information

MODEL AT-10 ANALOG TRANSMITTER

MODEL AT-10 ANALOG TRANSMITTER MODEL AT-10 ANALOG TRANSMITTER INSTALLATION & OPERATING MANUAL Industrial Weighing Systems 9 Richmond Street Picton, Ontario K0K 2T0 Phone: 613-921-0397 Fax: 613-476-5293 Web: www.iwsystems.ca info@iwsystems.ca

More information

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at USER MANUAL Model MA150 200A AC Mini Clamp-on Meter Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech MA150 AC Mini Clamp Meter. This device

More information

User Guide. Digital AC/DC Clamp Meter Model 38394

User Guide. Digital AC/DC Clamp Meter Model 38394 User Guide Digital AC/DC Clamp Meter Model 38394 Introduction Congratulations on your purchase of Extech s 38394 AC/DC Clamp Meter. This clamp meter measures AC/DC Current to 600A, DC/AC Voltage, Resistance,

More information

400Amp True RMS AC/DC Clamp Meter Model EX613

400Amp True RMS AC/DC Clamp Meter Model EX613 User's Guide 400Amp True RMS AC/DC Clamp Meter Model EX613 Introduction Congratulations on your purchase of this Extech EX613 True RMS Clamp Meter. This meter measures AC Current, DC Current, AC/DC Voltage,

More information

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter User s Manual MiniTec TM Series Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter Introduction Congratulations on your purchase of Extech s MN26 Autoranging Multimeter. This

More information

Controls. LCD display A B C D E F

Controls. LCD display A B C D E F H205 Version 1 1 2 3 4 5 6 13 12 11 7 8 9 10 14 15 17 18 16 1 19 Controls 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Carrying strap holder Preset 1 Preset 2 Preset 3/STEP button Preset 4 LCD display

More information

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com USER'S MANUAL ACDC-100 TRMS ACDC-100 Versatile AC/DC Clamp-on Multimeter Series 1 1) SAFETY This manual contains information

More information

User s Guide. Digital AC/DC Clamp Meter Model 38394

User s Guide. Digital AC/DC Clamp Meter Model 38394 User s Guide Digital AC/DC Clamp Meter Model 38394 Introduction Congratulations on your purchase of Extech s 38394 AC/DC Clamp Meter. This clamp meter measures AC/DC Current to 600A, DC/AC Voltage, Resistance,

More information

Model & MultiScope TM

Model & MultiScope TM Owner's Manual Model 381270 & 381275 MultiScope TM CAUTION: Read, understand and follow all Safety Rules and Operating Instructions in this manual before using this product. Test Equipment Depot - 800.517.8431-99

More information

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO AMPROBE 1 Congratulations! You are now the owner of an AMPROBE Instrument. It has been quality crafted according to quality standards and contains quality components

More information

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series USER'S MANUAL ACD-6 Pro ACD-6 TRMS Pro Versatile Clamp-on Multimeter Series 1 1) SAFETY This manual contains information and warnings that must be followed for operating the instrument safely and maintaining

More information

EDACS WALL MOUNT STATION. Maintenance Manual. Mobile Communications LBI-31838A TABLE OF CONTENTS

EDACS WALL MOUNT STATION. Maintenance Manual. Mobile Communications LBI-31838A TABLE OF CONTENTS A Mobile Communications EDACS WALL MOUNT STATION TABLE OF CONTENTS SYSTEM BOARD & REGULATOR BOARD.......... LBI-31892 KEY/DISPLAY BOARD MAINTENANCE MANUAL.... LBI-31940 Maintenance Manual Printed in U.S.A.

More information

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter DL6508 User's Guide 1500Amp True RMS AC/DC Clamp Meter Introduction Congratulations on your purchase of this DL6508 True RMS Clamp Meter. This meter measures AC Current, DC Current, AC/DC Voltage, Resistance,

More information

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

User's Guide Extech EX Amp Clamp Meter with IR Thermometer User's Guide Extech EX810 1000 Amp Clamp Meter with IR Thermometer Patented Introduction Congratulations on your purchase of the Extech EX810 Clamp Meter. This meter measures AC/DC Voltage, AC Current,

More information

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER with Temperature Probe Copyright 2007 Elenco Electronics, Inc. Contents 1. Safety Information 3,4 2. Safety Symbols 5 3. Front Plate

More information

Detcon Model FP Transmitter Test Fixture Operators Instruction Manual June 17, 2008 * Document 3389 * Revision 1.1

Detcon Model FP Transmitter Test Fixture Operators Instruction Manual June 17, 2008 * Document 3389 * Revision 1.1 Operators Instruction Manual June 17, 2008 * Document 3389 * Revision 1.1 DETCON, Inc. 3200 Research Forest Dr., Building A-1 The Woodlands, Texas 77387 Ph. 713-559-9200 / Fax 281-298-2868 www.detcon.com

More information

PH METER OPERATION MANUAL. Model : PH-208

PH METER OPERATION MANUAL. Model : PH-208 PH METER Model : PH-208 Your purchase of this PH METER marks a step forward for you into the field of precision measurement. Although this PH METER is a complex and delicate instrument, its durable structure

More information

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use http://www.all-sun.com EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL V Read this owners manual thoroughly before use WARRANTY This instrument is warranted to be free from defects in material and workmanship

More information

Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR

Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model 6012-06XR Specifications & Dimensions 2 Theory of Operation 3 System Block Diagram 4 Operator Controls & Connectors 5 Test Connections

More information

Fluke 123/124 Industrial ScopeMeter

Fluke 123/124 Industrial ScopeMeter Fluke 123/124 Industrial ScopeMeter Getting started GB Sep 2002 2002 Fluke Corporation, All rights reserved. Printed in The Netherlands All product names are trademarks of their respective companies. 1

More information

User s Guide. Model MA A AC Mini Clamp-on Meter

User s Guide. Model MA A AC Mini Clamp-on Meter User s Guide Model MA150 200A AC Mini Clamp-on Meter Introduction Congratulations on your purchase of Extech s MA150 AC Mini Clamp Meter. This meter is shipped fully tested and calibrated and, with proper

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL INSTALLATION & OPERATION MANUAL AN25 Totalizer/ Rate Indicator DOC#: MN-AN25.doc Sponsler Co., Inc. AN25 Totalizer/Rate Indicator pg. 2 DOC#: MN-AN25 SPECIFICATIONS Temperature: Operating 0 to 70 C Storage

More information

Model & MultiScope TM

Model & MultiScope TM Owner's Manual Model 381270 & 381275 MultiScope TM CAUTION: Read, understand and follow all Safety Rules and Operating Instructions in this manual before using this product. TABLE OF CONTENTS Page Safety

More information

Assembly Manual for VFO Board 2 August 2018

Assembly Manual for VFO Board 2 August 2018 Assembly Manual for VFO Board 2 August 2018 Parts list (Preliminary) Arduino 1 Arduino Pre-programmed 1 Faceplate Assorted Header Pins Full Board Rev A 10 104 capacitors 1 Rotary encode with switch 1 5-volt

More information

Jaguar Motor Controller (Stellaris Brushed DC Motor Control Module with CAN)

Jaguar Motor Controller (Stellaris Brushed DC Motor Control Module with CAN) Jaguar Motor Controller (Stellaris Brushed DC Motor Control Module with CAN) 217-3367 Ordering Information Product Number Description 217-3367 Stellaris Brushed DC Motor Control Module with CAN (217-3367)

More information

UT207A/208A/209A Operating Manual. Table of Contents

UT207A/208A/209A Operating Manual. Table of Contents Table of Contents Title Overview Unpacking Inspection Safety Information Rules for Safe Operation International Electrical Symbols The Meter Structure Display Symbols Functional Buttons The Effectiveness

More information

APPA 300 Series. The Most User-Friendly High Performance Multimeter

APPA 300 Series. The Most User-Friendly High Performance Multimeter APPA 300 Series The Most User-Friendly High Performance Multimeter Throw Away the Manual... So Easy, So Simple Straight Forward... For basic application, simply to operate these keys... "LIGHT" "BAR" "DIGIT"

More information

PIE 525B. Automated Thermocouple & RTD Calibrator Operating Instructions. Practical Instrument Electronics

PIE 525B. Automated Thermocouple & RTD Calibrator Operating Instructions. Practical Instrument Electronics PIE 525B Automated Thermocouple & RTD Calibrator Operating Instructions Practical Instrument Electronics 82 East Main Street Suite 3.14 Webster, NY 14580 USA Tel: 585.872.9350 Fax: 585.872.2638 sales@piecal.com

More information