ig5a Compact AC Drive 0.4~1.5kW(0.5~2HP) 1-phase 200~230Volts 0.4~22kW(0.5~30HP) 3-Phase 200~230Volts 0.4~22kW(0.5~30HP) 3-Phase 380~480Volts

Size: px
Start display at page:

Download "ig5a Compact AC Drive 0.4~1.5kW(0.5~2HP) 1-phase 200~230Volts 0.4~22kW(0.5~30HP) 3-Phase 200~230Volts 0.4~22kW(0.5~30HP) 3-Phase 380~480Volts"

Transcription

1 iga Compact AC Drive ~1.kW(0.~2HP) 1-phase 200~230Volts ~22kW(0.~30HP) 3-Phase 200~230Volts ~22kW(0.~30HP) 3-Phase 380~480Volts

2 Drive STARVERT iga LS Starvert iga is very competitive in its price and shows an upgraded functional strength. User-friendly interface, extended drive ranges up to 22kW, superb torque competence and small size of iga provides an optimum use environment. Standard compliance Compactness iga High performance Userfriendliness & Easy maintenance 2

3 Compact & Powerful Drive iga Contents Overview Model & Type Standard Specifications Wiring Terminal Configurations Keypad Features Parameter Setting Trial Run Dimensions Braking Resistors and Peripheral Devices Function List Protective Functions Fault Remedy Drive Starvert iga Series 3

4 iga Powerful & Upgraded Performance iga provides sensorless vector control, PID control, and ground-fault protection through powerful built-in functions. Sensorless vector control The built-in sensorless vector control provides the superb speed control and powerful high torque. Torque (%) Speed vs Torque Characteristics Ground-fault protection during running The ground-fault protection of output terminal is possible during running. Condition: Sensorless Vector Control Mode: Auto tuning Measure maximum torque (%) at each speed (1//10/20/30/40/0/60Hz) Speed (Hz) Analog control from -10V to 10V Inputting analog signals from -10V to 10V provides user-friendly operation. +10 Forward -10 Reverse Built-in PID control The built-in PID function enables to control flow-rate, oil-pressure, temperature, etc without any extra controller. PID control Pl PI control Built-in dynamic braking circuit The built-in dynamic braking circuit minimizes deceleration time via braking resistors. Speed With braking resistor Normal state Built-in 48 communication The built-in RS-48 communication supports remote control and monitoring between iga and other equipment. Reducing deceleration time Time Wide product range iga consists of the product range from to 22KW. 4

5 Compact & Powerful Drive iga RS-48 communication Connected to PC RS C converter Monitoring Checking operation status (Voltage, Current, Frequency, etc) Checking modified parameters Windows support Remote Control Convenient remote control to modify operation status (Forward/Reverse operation, Frequency, etc) Easy parameter setting Available to control up to 31 Drives RS-48, Modbus communication Connected to XGT panel Monitoring Checking operation time Automatic list-up of trip record Language support (Korean, English, Chinese) Remote Control Convenient remote control to modify operation status (Forward/Reverse operation, Frequency, etc) Easy parameter setting Available to control up to 31 Drives RS-48, Modbus communication Drive Starvert iga Series

6 iga User-friendly Interface & Easy Maintenance The parameter setting becomes easier by adopting the 4 directions key. And iga supports easy maintenance via diagnosis and fan changeable structure. Diagnosis of output module Through easy parameter setting, iga can diagnose the status of output module. Easy change of fan iga is designed to be the fan changeable structure in preparation for a fan breakdown. Cooling fan control By controlling the cooling fan, iga provides a virtually quiet environment according to the status of operation. User-friendly interface The 4 directions key provides easy handling and monitoring. External loader (Optional) The external loader away from a panel enables to control and monitor conveniently. And the parameters made by external loader can be copied and applicable to other Drives. Loader type + External type (Optional) Model name INV, REMOTE KPD 2M (SV-iGA) INV, REMOTE KPD 3M (SV-iGA) INV, REMOTE KPD M (SV-iGA) Remarks 2m 3m m 6

7 Compact & Powerful Drive iga Compact Size The compact size achieves cost-efficiency and various applications. Same height from to 4.0kW (128mm) Global standard compliance CE UL Global standard iga series complies with CE and UL standards. PNP/NPN input Both PNP and NPN inputs become possible and these enable to use the outer power. To do so, users will be given wider choices of selecting the controller. Drive Starvert iga Series 7

8 iga Model & Type Applicable motor ranges 1 Phase 200V 3 Phase 200V 3 Phase 400V kw (0.HP) SV004iGA-1 SV004iGA-2 SV004iGA-4 0.7kW (1HP) SV008iGA-1 SV008iGA-2 SV008iGA-4 1.kW (2HP) SV0iGA-1 SV0iGA-2 SV0iGA-4 2.2kW (3HP) SV022iGA-2 SV022iGA-4 3.7kW (HP) SV037iGA-2 SV037iGA-4 4.0kW (.4HP) SV040iGA-2 SV040iGA-4.kW (7.HP) SV0iGA-2 SV0iGA-4 7.kW (10HP) SV07iGA-2 SV07iGA kW (HP) SV110iGA-2 SV110iGA-4.0kW (20HP) SV0iGA-2 SV0iGA-4 18.kW (2HP) SV18iGA-2 SV18iGA kW (30HP) SV220iGA-2 SV220iGA-4 SV 0 iga 2 STARVERT Motor rating (kw) (004: kw~220: 22kW) iga series Input voltage (1: 1 phase 200~230[V], 2: 3 phase 200~230[V], 4: 3 phase 380~480[V]) 8

9 Compact & Powerful Drive iga Standard Specifications 1 Phase 200V SV iga Max. capacity 1) (HP) (kw) Capacity (kva) 2) Output rating FLA (A) 3) Max frequency [Hz] 4) 8 Max voltage 3 phase 200~230V ) Input rating Rated voltage Rated frequency 1phase 200~230 VAC (+10%, -%) 0~60 [Hz] (±%) Cooling method Forced air cooling Weight (kg) Phase 200V SV iga Max. (HP) capacity 1) (kw) Capacity (kva) 2) Output rating FLA (A) 3) Max frequency [Hz] 4) Max voltage 3 phase 200~230V ) Input rating Rated voltage Rated frequency 3 phase 200~230 (+10%, -%) 0~60 [Hz] (±%) Cooling method N/C 6) Forced air cooling Weight (kg) Phase 400V SV iga Max. (HP) capacity 1) (kw) Capacity (kva) 2) Output rating FLA (A) 3) Max frequency [Hz] 4) Max voltage 3 phase 380~480V ) Input rating Rated voltage Rated frequency 3 phase 380~480 VAC (+10%, -%) 0~60 [Hz] (±%) Cooling method N/C 6) Forced air cooling Weight (kg) ) Indicate the maximum applicable motor capacity when using 4 pole LS standard motor. 2) Rated capacity is based on 220V for 200V series and 440V for 400V series. 3) Refer to -3 of userʼs manual when carrier frequency setting (39) is above 3kHz. 4) Max. frequency setting range is extended to 300Hz when H40 (Control mode select) is set to 3 (Sensorless vector control). ) Max. output voltage cannot be higher than the input voltage. It can be programmable below input voltage. 6) Self-Cooling Drive Starvert iga Series 9

10 iga Standard Specifications Control Control method Frequency setting resolution Frequency accuracy V/F pattern Overload capacity Torque boost Dynamic braking Operation mode Frequency setting Operation features Max. braking torque Max. Duty V/F, Sensorless vector control Digital command: 0.01Hz Analog command: 0.06Hz (Max. freq.: 60Hz) Digital command: 0.01% of Max. output frequency Analog command: 0.1% of Max. output frequency Linear, Squared, User V/F 0% per 1 min. Manual/Auto torque boost 20% 1) 0% when using optional DB resistor 2) Keypad/ Terminal/ Communication option/ Remote keypad selectable Analog: 0~10V, -10~10V, 0~20mA Digital: Keypad PID, Up-down, 3-wire NPN/PNP selectable Operation Input Multi-function terminal P1~P8 FWD/REV RUN, Emergency stop, Fault reset, Jog operation, Multi-step Frequency-High, Mid, Low, Multi-step Accel/Decel-High, Mid, Low, DC braking at stop, 2nd motor select, Frequency UP/Down, 3-wire operation, External trip A, B, PID-Drive (V/F) operation bypass, Option-drive (V/F) operation bypass, Analog Hold, Accel/Decel stop Output Open collector terminal Multi-function relay Fault output and drive status output Less than DC 26V, 100mA (N.O., N.C.) Less than AC 20V, 1A; Less than DC 30V, 1A Protective function Environ ment Analog output (AM) Trip Alarm Momentary power loss Protection degree Ambient temp Storage temp Humidity Altitude/Vibration Atmospheric pressure Location 0~10Vdc (less than 10mA): Output freq, Output current, Output voltage, DC link selectable Over voltage, Under voltage, Over current, Ground fault current detection, Drive overheat, Motor overheat, Output phase open, Overload protection, Communication error, Loss of speed command, Hardware fault, Fan trip Stall prevention, Overload Below msec: Continuous operation (Should be within rated input voltage, rated output power.) Above msec: Auto restart enable IP 20, NEMA1 (Ambient Temperature 40 ) 3) -10 ~0-20 ~6 Below 90% RH (No condensation) Below 1,000m (From 1000 to 4000m, the rated input voltage and rated output current of the drive must be derated by 1% for every 100m.),.9m/sec 2 (0.6G) 70~106 kpa Protected from corrosive gas, Combustible gas, Oil mist or dust 1) Means average braking torque during Decel to stop of a motor. 2) Refer to Chapter 16 of userʼs manual for DB resistor specification. 3) UL Type1 with top cover and conduit box installed. 10

11 Compact & Powerful Drive iga Wiring ~7.kW DB resistor (Optional) 3 phase AC input (Rated input voltage) B1 B2 R U S T V W G Ground 24 24V output P1 FX (Forward run) P2 RX (Reverse run) AM CM Multi-function analog output signal: 0~10V CM Input signal common P3 BX (Emergency stop) P4 RST (Trip reset) P JOG (Jog operation) 3A A contact output CM Input signal common P6 Multi-step freq. - Low P7 Multi-step freq. - Middle 3C 3B A/B contact common B contact output P8 Multi-step freq. - High Potentiometer (1kohm, 1/2W) MO Multi-function open collector output VR 10V power supply for potentiometer MG MO Common V1 Freq. Setting Voltage signal input: -10~10V S+ I Freq. Current signal input: 0~20mA CM Input signal common S- RS-48 communication terminal Drive Starvert iga Series 11

12 iga Wiring 11.0~22.0kW DC reactor DB resistor (Optional) 3 phase AC input (Rated input voltage) P1(+) B1 B2 N(-) R S T G U V W Ground 24 24V output P1 FX (Forward run) P2 RX (Reverse run) AM CM Multi-function analog output signal: 0~10V CM Input signal common P3 BX (Emergency stop) P4 RST (Trip reset) P JOG (Jog operation) 3A A contact output CM Input signal common P6 Multi-step freq. - Low P7 Multi-step freq. - Middle 3C 3B A/B contact common B contact output P8 Multi-step freq. - High Potentiometer (1kohm, 1/2W) MO Multi-function open collector output VR 10V power supply for potentiometer MG MO Common V1 Freq. Setting Voltage signal input: -10~10V I Freq. Current signal input: 0~20mA CM Input signal common S+ S- RS-48 communication terminal 12

13 Compact & Powerful Drive iga Wiring Specifications for power terminal block wiring kw~0.7kw (1 phase) kw~1.kw (3 phase) 1.kW (1 phase) R T B1 B2 R S T B1 U V W U.kW~7.kW (3 phase) B1 B2 U V W B2 R T B1 2.2~4.0kW (3 phase) V W R S T B1 11~22kW (3 phase) B2 B2 U U V V W W R S T B1 B2 R(L1) S(L2) T(L3) P1(+) N(-) U V W SV0004iGA-1 SV0008iGA-1 SV00iGA-1 SV0004iGA-2 SV0008iGA-2 SV00iGA-2 SV0022iGA-2 SV0037iGA-2 SV0040iGA-2 SV00iGA-2 SV007iGA-2 SV0110iGA-2 SV00iGA-2 SV018iGA-2 SV0220iGA-2 SV0004iGA-4 SV0008iGA-4 SV00iGA-4 SV0022iGA-4 SV0037iGA-4 SV0040iGA-4 SV00iGA-4 SV007iGA-4 SV0110iGA-4 SV00iGA-4 SV018iGA-4 SV0220iGA-4 R, S, T wire U, V, W wire Ground wire mm 2 AWG mm 2 AWG mm 2 AWG Terminal Screw Size M3. M3. M4 M3. M3. M3. M4 M4 M4 M M M6 M6 M8 M8 M3. M3. M4 M4 M4 M4 M M M M M6 M6 Screw Torque (kgf.cm) / lb-in 10/8.7 10/8.7 /13 10/8.7 10/8.7 10/8.7 /13 /13 /13 32/28 32/ / / / /26. 10/8.7 10/8.7 /13 /13 /13 /13 32/28 32/ / / / /26. Drive Starvert iga Series 13

14 iga Terminal Configuration Control terminal specifications MO MG 24 P1 P2 CM P3 P4 S- S+ 3A 3B 3C P CM P6 P7 P8 VR V1 I AM Terminal P1~P8 CM Multi-function input T/M 1-8 Common terminal Wire size (mm 2 ) Single wire Stranded Screw size M2.6 M2.6 1) Torque (Nm) Specification VR V1 Power supply for external potentiometer Input terminal for voltage operation M2.6 M2.6 Output voltage: 12V Max. output current: 100mA Potentiometer: 1~kohm Max. input voltage: -10V~+10V input I Input terminal for current operation M2.6 0~20mA input Internal resistor: 20ohm AM Multi-function analog output terminal M2.6 Max. output voltage: 11V Max. output current: 10mA MO MG 24 3A 3B 3C Multi-function terminal for open collector Ground terminal for external power supply 24V external power supply Multi-function relay output A contact Multi-function relay output B contact Common for multi-function relays M2.6 M2.6 M2.6 M2.6 M2.6 M2.6 Below DC 26V,100mA Max. output current: 100mA Below AC 20V, 1A Below DC 30V, 1A 1) Use the recommended tightening torque when securing terminal screws. When you use external power supply (24V) for multi-function input terminal (P1~P8), apply voltage higher than 12V to activate. Tie the control wires more than cm away from the control terminals. Otherwise, it interferes front cover reinstallation. 14

15 Compact & Powerful Drive iga Keypad Features Display Term RUN Run key STOP/RESET STOP/RESET key Up key Down key KEY Right key Left key Enter key FWD Forward run 1) REV Reverse run LED RUN Run key SET Setting 1) 4 LEDs above are set to blink when a fault occurs. Run command STOP: Stop command during operation, RESET: Reset command when a fault occurs. Used to scroll through codes or increase parameter value Used to scroll through codes or decrease parameter value Used to jump to other parameter groups or move a cursor to the right to change the parameter value Used to jump to other parameter groups or move a cursor to the left to change the parameter value Used to set the parameter value or save the changed parameter value Lit during forward run Lit during reverse run Lit during operation Lit during parameter setting Dimensions 2-Φ4. SET RUN RUN C L ENT FWD REV STOP RESET Drive Starvert iga Series

16 iga Moving to Other Groups Parameter groups There are 4 different parameter groups in iga series as shown below. Parameter group Drive group Function group 1 Function group 2 I/O (Input/Output) group Basic parameters necessary for the drive to run. Parameters such as Target frequency, Accel/Decel time settable. Basic function parameters to adjust output frequency and voltage. Advanced function parameters to set parameters for such as PID Operation and second motor operation. Parameters necessary to make up a sequence using multi-function input/output terminal. Moving to other groups Moving to other groups using the Right ( ) key Moving to other groups using the Left ( ) key 1) 1) 1) Target frequency can be set at 0.0 (the 1st code of drive group). Even though the preset value is 0.0, it is user-settable. The changed frequency will be displayed after it is changed. 16

17 Compact & Powerful Drive iga When changing ACC time from.0 sec to 16.0 sec In the first code 0.00, press the Up ( ) key once to go to the second code. ACC [Accel time] is displayed. Press the Ent ( ) key once. Preset value is.0, and the cursor is in the digit 0. Press the Left ( ) key once to move the cursor to the left. The digit in.0 is active. Then press the Up ( ) key once. The value is increased to 6.0 Press the Left ( ) key to move the cursor to the left is displayed. The first 0 in 0.60 is active. Press the Up ( ) key once is set. Press the Ent ( ) key once is blinking. 1) Press the Ent ( ) key once again to return to the parameter name. 8 ACC is displayed. Accel time is changed from.0 to 16.0 sec. 1) Pressing the Left ( )/Right ( )/Up ( )/Down ( ) key while a cursor is blinking will cancel the parameter value change. Pressing the Ent ( ) key in this status will enter the value into memory. In step 7, pressing the Left ( ) or Right ( ) key while 16.0 is blinking will disable the setting. Code change in Drive group In the 1st code in Drive group 0.00, press the Up ( ) key once. The 2nd code in Drive group ACC is displayed. Press the Up ( ) key once. The 3rd code dec in Drive group is displayed. Keep pressing the Up ( ) key until the last code appears. The last code in Drive group drc is displayed. Press the Up ( ) key again. Return to the first code of Drive group. Use Down ( ) key for the opposite order. Drive Starvert iga Series 17

18 iga Trial Run Multi-step operation + Run/Stop via FX/RX + Max. frequency change Operation condition Operation command: Run/Stop via FX/RX Frequency command: Multi-step operation [Low (20), Middle (30), High (80)] Max. frequency change: From 60Hz to 80Hz Wiring S1 P1 (Forward) S2 S3 S4 P2 (Reverse) P6 (Low) P7 (Middle) 3 phase AC input R S T G U V W S P8 (High) S / W P1 (Forward) P2 (Reverse) CM P6 (Low) P7 (Middle) P8 (High) CM 1. Please make sure that R, S, T are connected to 3 phase AC input, and U, V, W are also motor connection terminals. 2. After supplying the power, please set the frequency of multi-step among Low, Middle, and High. 3. If P1 (FX) turns on, the motor operates in forward. And after turning off, it stops according to the deceleration time. 4. If P2 (RX) turns on, the motor operates in reverse. And after turning off, it stops according to the deceleration time. VR V1 CM Parameter setting Step Command Code Default After change Max. frequency change (FU1) Multi-step frequency (DRV) Multi-step frequency (DRV) Multi-step frequency (I/O) Forward run (P1: FX) Reverse run (P2: RX) F21 st1 st2 I30 I17 I18 Change Max. frequency. Set Low step. Set Middle step. Set High step. The default is FX. This value may change. The default is RX. This value may change. 60Hz 10Hz 20Hz 30Hz FX RX 80Hz 20Hz 30Hz 80Hz FX RX 18

19 Compact & Powerful Drive iga Potentiometer (Volume) + Run/Stop via FX/RX + Accel/Decel time change Operation condition Operation command: Run/Stop via FX/RX Wiring Frequency command: 0~60Hz analog input via potentiometer Accel/Decel time: Accel-10sec, Decel-20sec Potentiometer 1~kohm, 1/2W VR V1 CM 3 phase AC input R S T G U V W Motor 0~60Hz P1 (FX) Forward P2 (RX) Reverse CM 1. Please make sure that R, S, T are connected to 3 phase AC input, and U, V, W are also motor connection terminals. 2. After supplying the power, please set the frequency of multi-step among Low, Middle, and High. 3. If P1 (FX) turns on, the motor operates in forward. And after turning off, it stops according to the deceleration time. 4. If P2 (RX) turns on, the motor operates in reverse. And after turning off, it stops according to the deceleration time.. Control the motorʼs speed via potentiometer. VR V1 CM Potentiometer 1~kohm, 1/2W Parameter setting Step Command Code Default After change 1 Operation command (DRV group) Drv Turn on/off motor via terminal. 1 (FX/RX-1) 1 (FX/RX-1) 2 Analog input (DRV group) Frq Change keypad command to analog voltage command. 0 (Keypad-1) 3 (V1: 0~10V) 3 Accel/Decel time (DRV group) ACC dec Set Accel time to 10sec in ACC Set Decel time to 20sec in dec. sec (Accel) 10sec (Decel) 10sec (Accel) 20sec (Decel) 4 Forward run (P1: FX) I17 The default is FX. This value may change FX FX Reverse run (P2: RX) I18 The default is RX. This value may change. RX RX Drive Starvert iga Series 19

20 iga Dimensions SV004iGA-1, SV004iGA-2 / SV008iGA-2, SV004iGA-4 / SV008iGA-4 W A A W1 H1 Φ H D B W1 mm (inches) Drive model (kw) W (mm) W1 (mm) H (mm) H1 (mm) D (mm) Φ A (mm) B (mm) (kg) SV004IGA-1 SV004IGA-2 SV008IGA-2 SV004IGA-4 SV008IGA SV008iGA-1, SV0iGA-2, SV0iGA-4 W W1 A1 A H1 Φ H D B W1 mm (inches) 20 Drive model (kw) W (mm) W1 (mm) H (mm) H1 (mm) D (mm) Φ A (mm) B (mm) (kg) SV0IGA-1 SV0IGA-2 SV0IGA

21 Compact & Powerful Drive iga SV0iGA-1, SV022iGA-2 / SV037iGA-2 / SV040iGA-2, SV022iGA-4 / SV037iGA-4 / SV040iGA-4 W A Φ H1 C L H D B B W1 mm (inches) Drive model (kw) W (mm) W1 (mm) H (mm) H1 (mm) D (mm) Φ A (mm) B (mm) (kg) SV0IGA-1 SV022IGA-2 SV037IGA-2 SV040IGA-2 SV022IGA-4 SV037IGA-4 SV040IGA SV0iGA-2 / SV07iGA-2, SV0iGA-4 / SV07iGA-4 W A Φ W A H1 H D B B W1 mm (inches) Drive model (kw) W (mm) W1 (mm) H (mm) H1 (mm) D (mm) Φ A (mm) B (mm) (kg) SV0IGA-2 SV07IGA-2 SV0IGA-4 SV07IGA Drive Starvert iga Series 21

22 iga Dimensions SV110iGA-2 / SV0iGA-2 / SV110iGA-4 / SV0iGA-4 W A W1 Φ A H1 H D B B W1 mm (inches) Drive model (kw) W (mm) W1 (mm) H (mm) H1 (mm) D (mm) Φ A (mm) B (mm) (kg) SV110iGA-2 SV0iGA-2 SV110iGA-4 SV0iGA SV018iGA-2 / SV0220iGA-2 / SV018iGA-4 / SV0220iGA-4 W Φ A W1 A H1 H D B W1 B mm (inches) 22 Drive model (kw) W (mm) W1 (mm) H (mm) H1 (mm) D (mm) Φ A (mm) B (mm) (kg) SV18iGA-2 SV220iGA-2 SV18iGA-4 SV220iGA

23 Braking Resistors and Peripheral Devices Compact & Powerful Drive iga Braking resistors Voltage 200V Series 400V Series Drive % braking 0% braking Resistor [Ω] Watt [W] 1) Resistor [Ω] Watt [W] 1) , ,000 1,400 2,000 2,400 2, ,000 1,400 2,000 2,400 2, , ,200 2,400 2,400 3,600 3, ,000 1,200 2,000 2,400 3,600 3,600 1) The wattage is based on Enable Duty (%ED) with continuous braking time sec. Breakers Voltage 1-Phase 200V 3-Phase 200V 3-Phase 400V Capacity [kw] Model ABS33c ABS33c ABS3c ABS63c ABS103c ABS203c ABS33c ABS3c ABS63c ABS103c Circuit Breaker (MCCB) Leakage Breaker (ELCB) Magnetic Contactor (MC) Rated Current [A] Model Rated Current [A] Model Rated Current [A] Model Rated Current [A] UTE100 UTE100 UTS0 UTS20 UTE EBS33c EBS33c EBS3c EBS63c EBS103c EBS203c EBS33c EBS3c EBS63c EBS103c Note) 1. The capacity of the MCCB should be 1. to 2 times the rated output current of the drive. 2. Use an MCCB keep the drive from faulting out instead of using overheat protection (0% for one minute at the rated output current.) 3. In case magnetic contactor is used on single-phase product, wire R and T phases MC-6a MC-9a, MC-9b MC-18a, MC-18b MC-6a MC-9a, MC-9b MC-18a, MC-18b MC-22b MC-32a MC-0a MC-6a MC-8a MC-130a MC-0a MC-18a MC-6a MC-9a, MC-9b MC-12a, MC-12b MC-18a, MC-18b MC-22b MC-32a MC-0a MC-6a MC-7a MC-8a Drive Starvert iga Series 23

24 iga Braking Resistors and Peripheral Devices Fuses & AC reactors Model 004iGA-1 008iGA-1 0iGA-1 004iGA-2 008iGA-2 0iGA-2 022iGA-2 037iGA-2 040iGA-2 0iGA-2 07iGA-2 110iGA-2 0iGA-2 18iGA-2 220iGA-2 004iGA-4 008iGA-4 0iGA-4 022iGA-4 037iGA-4 040iGA-4 0iGA-4 07iGA-4 110iGA-4 0iGA-4 18iGA-4 220iGA-4 Current [A] 10 A 10 A A 10 A 10 A A 2 A 30 A 30 A 30 A 0 A 70 A 100 A 100 A 12 A A 10 A 10 A 10 A 20 A 20 A 20 A 30 A 3 A 4 A 60 A 70 A AC external fuse Voltage [V] AC reactor 4.20 mh, 3. A 2.13 mh,.7 A 1.20 mh, 10 A 4.20 mh, 3. A 2.13 mh,.7 A 1.20 mh, 10 A 0.88 mh, 14 A 0.6 mh, 20 A 0.6 mh, 20 A 0.39 mh, 30 A 0.28 mh, 40 A 0.20 mh, 9 A 0. mh, 7 A 0.12 mh, 96 A 0.10 mh, 112 A 18.0 mh, 1.3 A 8.63 mh, 2.8 A 4.81 mh, 4.8 A 3.23 mh, 7. A 2.34 mh, 10 A 2.34 mh, 10 A 1.22 mh, A 1.14 mh, 20 A 0.81 mh, 30 A 0.61 mh, 38 A mh, 0 A 0.39 mh, 8 A DC reactor mh, 6 A 0.7 mh, 71 A 9 mh, 91 A 2 mh, 107 A mh, 29 A 2.18 mh, 36 A 1.79 mh, 48 A 1.4 mh, A 24

25 Compact & Powerful Drive iga Function List Drive Group LED display Address for communication Parameter name Min/Max range Factory defaults Adj. during run This parameter sets the frequency that the drive is commanded to output A100 [Frequency 0 ~ 400 command] [Hz] During Stop: Frequency Command During Run: Output Frequency During Multi-step operation: Multi-step frequency 0. It cannot be set greater than F21- [Max frequency] O ACC dec A101 A102 [Accel time] [Decel time] 0 ~ 6000 [Sec] During Multi-Accel/Decel operation, this parameter serves as Accel/Decel time 0..0 O 10.0 O 0 Run/Stop via Run/Stop key on the keypad drv Frq St1 St2 St3 A103 [Drive mode] 0 ~ 3 A104 [Frequency setting method] 0 ~ 7 A10 [Multi-Step frequency 1] A106 [Multi-Step 0 ~ 400 frequency 2] [Hz] A107 [Multi-Step frequency 3] FX: Motor forward run 1 RX: Motor reverse run Terminal operation FX: Run/Stop enable 2 RX: Reverse rotation select 3 RS48 communication 4 Set to Field Bus communication 1) 0 Keypad setting 1 Digital 1 Keypad setting 2 2 V1 1: -10 ~ +10 [V] 3 V1 2: 0 ~ +10 [V] 4 Analog Terminal I: 0 ~ 20 [ma] Terminal V1 setting 1 + Terminal I 6 Terminal V1 setting 2+ Terminal I 7 RS48 communication 8 Digital Volume 9 Set to Field Bus communication 1) Sets Multi-Step frequency 1 during Multi-step operation. Sets Multi-Step frequency 2 during Multi-step operation. Sets Multi-Step frequency 3 during Multi-step operation. 1 X O O O CUr A108 [Output current] Displays the output current to the motor. - - rpm A109 [Motor RPM] Displays the number of Motor RPM. - - A10A [Drive DC dcl link voltage] [User display vol A10B select] 1) This function can be available with iga Communication Option Module. Displays DC link voltage inside the drive. This parameter displays the item selected at H73- [Monitoring item select]. vol Output voltage POr Output power tor Torque - - vol - Drive Starvert iga Series 2

26 iga Function List Drive Group LED display non drc drv2 1) Frq2 2) ref 2) Fbk Address for communication A10C Parameter name [Fault Display] Min/Max range [Direction of A10D motor rotation F, r select] A10E [Drive mode 2] 0 ~ 3 [Frequency A10F setting 0 ~ 7 method 2] PID control 0~400[Hz] A110 standard or value setting 0~100 [%] A111 PID control feedback amount 1) Only displayed when one of the Multi-function input terminals 1-8 [I17~I24] is set to 22. 2) It is indicated when H49(PID control selection) is 1. 3) This function can be available with iga Communication Option Module. Displays the types of faults, frequency and operating status at the time of the fault Sets the direction of motor rotation when drv - [Drive mode] is set to either 0 or 1. F Forward r Reverse 0 Run/Stop via Run/Stop key on the keypad FX: Motor forward run 1 RX: Motor reverse run Terminal operation FX: Run/Stop enable 2 RX: Reverse rotation select 3 RS-48 communication 4 Set to Filed Bus Communication 3) 0 Keypad setting 1 Digital 1 Keypad setting 2 2 V1 1: -10 ~ +10 [V] 3 V1 2: 0 ~ +10 [V] 4 Analog Terminal I: 0 ~ 20 [ma] Terminal V1 setting 1 + Terminal I 6 Terminal V1 setting 2+ Terminal I 7 RS48 communication 8 Digital Volume 9 Set to Filed Bus Communication 3) If H8 is 0, it is expressed as a [Hz] unit. If H8 is 1, it is expressed as a [%] unit. In [Hz] unit, you canʼt set Max. frequency more than (F21). In [%] unit, 100% means Max. frequency. It indicates a feedback amount in PID control. If H8 is 0, it is expressed as a [Hz] unit. If H8 is 1, it is expressed as a [%] unit. Factory defaults - - F Adj. during run O 1 X Function group 1 LED display Address for communication Parameter name Min/Max range Factory defaults Adj. during run F 0 A200 [Jump code] 0 ~ 71 Sets the parameter code number to jump. 1 O F 1 [Forward/ A201 Reverse run 0 ~ 2 disable] 0 Fwd and rev run enable 1 Forward run disable 2 Reverse run disable F 2 F 3 A202 A203 [Accel pattern] [Decel pattern] 0 ~ 1 0 Linear 1 S-curve 26

27 Compact & Powerful Drive iga Function group 1 LED display Address for communication Parameter name Min/Max range Factory defaults Adj. during run 0 Decelerate to stop F 4 A204 [Stop mode select] 0 ~ 3 1 DC brake to stop 2 Free run to stop 3 Power Braking stop F 8 1) A208 [DC Brake 0.1 ~ 60 start frequency] [Hz] This parameter sets DC brake start frequency. It cannot be set below F23 - [Start frequency]..0 F 9 A209 [DC Brake 0 ~ 60 wait time] [sec] When DC brake frequency is reached, the drive holds the output for the setting time before starting DC brake. 0.1 X F10 A20A [DC Brake 0 ~ 200 voltage] [%] This parameter sets the amount of DC voltage applied to a motor. It is set in percent of H33 - [Motor rated current]. F11 A20B [DC Brake time] 0 ~ 60 [sec] This parameter sets the time taken to apply DC current to a motor while motor is at a stop. 1. F12 A20C [DC Brake start 0 ~ 200 voltage] [%] This parameter sets the amount of DC voltage before a motor starts to run. It is set in percent of H33 - [Motor rated current]. F13 A20D [DC Brake start 0 ~ 60 time] [sec] DC voltage is applied to the motor for DC Brake start time before motor accelerates. F14 A20E [Time for magnetizing a motor] 0 ~ 60 [sec] This parameter applies the current to a motor for the set time before motor accelerates during Sensorless vector control. 0.1 X F20 A214 [Jog frequency] 0 ~ 400 [Hz] This parameter sets the frequency for Jog operation. It cannot be set above F21 - [Max frequency] O This parameter sets the highest frequency the drive can output. It is frequency reference for Accel/Decel (See H70) 2) F21 A2 [Max frequency] 40 ~ 400 [Hz] Caution 60.0 Any frequency cannot be set above Max frequency except Base frequency F22 A216 [Base frequency] 30 ~ 400 [Hz] The drive outputs its rated voltage to the motor at this frequency (see motor nameplate) F23 A217 [Start frequency] 0.1 ~ 10 [Hz] The drive starts to output its voltage at this frequency. It is the frequency low limit. 0. F24 A218 [Frequency high /low limit select] 0 ~ 1 This parameter sets high and low limit of run frequency. 3) F2 A219 [Frequency 0 ~ 400 high limit] [Hz] This parameter sets high limit of the run frequency. It cannot be set above F21 - [Max frequency] F26 A21A [Frequency 0.1 ~ 400 low limit] [Hz] This parameter sets low limit of the run frequency. It cannot be set above F2 - [Frequency high limit] and below F23 - [Start frequency]. 0. F27 A21B [Torque Boost select] 0 ~ 1 0 Manual torque boost 1 Auto torque boost F28 A21C [Torque boost in forward direction] 0 ~ This parameter sets the amount of torque boost applied to a motor during forward run. It is set in percent of Max output voltage. 2 X F29 A21D [Torque boost [%] in reverse direction] This parameter sets the amount of torque boost applied to a motor during reverse run. It is set as a percent of Max output voltage. 2 X 1) Only displayed when F 4 is set to 1 (DC brake to stop). 2) If H40 is set to 3 (Sensorless vector), Max. frequency is settable up to 300Hz. 3) Only displayed when F24 (Frequency high/low limit select) is set to 1. Drive Starvert iga Series 27

28 iga Function List Function group 1 LED display Address for communication Parameter name Min/Max range Factory defaults Adj. during run 0 {Linear} F30 F31 1) F32 F33 F34 F3 F36 F37 F38 F39 F40 F0 2) F1 F2 F3 A21E [V/F pattern] 0 ~ 2 A21F A220 A221 A222 A223 A224 A22 A226 A227 A228 A232 A233 A234 A23 [User V/F 0 ~ 400 frequency 1] [Hz] [User V/F ] 0 ~ 100 voltage 1 [%] [User V/F 0 ~ 400 frequency 2] [Hz] [User V/F 0 ~ 100 voltage 2] [%] [User V/F 0 ~ 400 frequency 3] [Hz] [User V/F 0 ~ 100 voltage 3] [%] [User V/F 0 ~ 400 frequency 4] [Hz] [User V/F 0 ~ 100 voltage 4] [%] [Output voltage 40 ~ 110 adjustment] [%] [Energy-saving 0 ~ 30 level] [%] [Electronic thermal select] 0 ~ 1 [Electronic thermal level for 1 minute] [Electronic thermal level for continuous] [Motor cooling method] 0 ~ 200 [%] 0 ~ 0 [%] 0 ~ 1 1 {Square} 2 {User V/F} It is used only when V/F pattern is set to 2(User V/F) It cannot be set above F21 - [Max frequency]. The value of voltage is set in percent of H70 - [Motor rated voltage]. The values of the lower-numbered parameters cannot be set above those of higher-numbered. This parameter adjusts the amount of output voltage. The set value is the percentage of input voltage. This parameter decreases output voltage according to load status. This parameter is activated when the motor is overheated (timeinverse). This parameter sets max current capable of flowing to the motor continuously for 1 minute. The set value is the percentage of H33 - [Motor rated current]. It cannot be set below F2 - [Electronic thermal level for continuous]. This parameter sets the amount of current to keep the motor running continuously. It cannot be set higher than F1 - [Electronic thermal level for 1 minute]. Standard motor having cooling fan directly connected to 0 the shaft 1 A motor using a separate motor to power a cooling fan..0 2 X X F4 F A236 A237 1) Set F30 to 2(User V/F) to display this parameter. 2) Set F0 to 1 to display this parameter. [Overload 30 ~ 0 warning level] [%] [Overload 0 ~ 30 warning time] [Sec] This parameter sets the amount of current to issue an alarm signal at a relay or multi-function output terminal (see I4, I). The set value is the percentage of H33- [Motor rated current]. This parameter issues an alarm signal when the current greater than F4- [Overload warning level] flows to the motor for F- [Overload warning time]

29 Compact & Powerful Drive iga Function group 1 LED display Address for communication Parameter name Min/Max range Factory defaults Adj. during run F6 F7 F8 F9 F60 1) F61 F63 F64 2) F6 F66 F70 A238 A239 A23A A23B A23C A23D A23F A240 A241 A242 A246 [Overload trip select] 0 ~ 1 [Overload 30 ~ 200 trip level] [%] [Overload 0 ~ 60 trip time] [Sec] [Stall prevention select] 0 ~ 7 [Stall prevention 30 ~ 200 level] [%] [When Stall prevention during deceleration, voltage limit select [Save up/down frequency select] [Save up/down frequency] [Up-down mode select] 0~1 0 ~ 1 0~2 [Up-down step 0~400 frequency] [Hz] [Draw run mode select] 0~3 This parameter turns off the drive output when motor is overloaded. This parameter sets the amount of overload current. The value is the percentage of H33- [Motor rated current]. This parameter turns off the drive output when the F7- [Overload trip level] of current flows to the motor for F8- [Overload trip time]. This parameter stops accelerating during acceleration, decelerating during constant speed run and stops decelerating during deceleration. During Decel During constant run During Accel Bit 2 Bit 1 Bit This parameter sets the amount of current to activate stall prevention function during Accel, Constant or Decel run. The set value is the percentage of the H33- [Motor rated current]. In Stall prevention run during deceleration, if you want to limit output voltage, select 1 This parameter decides whether to save the specified frequency during up/down operation. When 1 is selected, the up/down frequency is saved in F64. If ʻSave up/down frequencyʼ is selected at F63, this parameter saves the frequency before the drive stops or decelerated. We can select up-down mode among three thing 0 Increases goal frequency as a standard of Max. frequency/min. frequency 1 Increases as many as step frequency according to edge input 2 Available to combine 1 and 2 In case of choosing F6 as a 1 or 2, it means increase or decrease of frequency according to up-down input 0 Drive doesnʼt run as a draw mode 1 V1(0~10V) input draw run 2 I(0~20mA) input draw run 3 V1(-10~10V) input draw run F71 A247 [Draw rate] 0~100[%] Sets rate of draw ) It is indicated when setting bit 2 of F9 as 1 2) Set F63 to 1 to display this parameter. Drive Starvert iga Series 29

30 iga Function List Function group 2 LED display Address for communication Parameter name Min/Max range Factory defaults Adj. during run H 0 A300 [Jump code] 0~9 Sets the code number to jump. 1 O H 1 A301 [Fault history 1] - non - H 2 A302 [Fault history 2] - Stores information on the types of faults, the frequency, the non - H 3 A303 [Fault history 3] - current and the Accel/Decel condition at the time of fault. The non - H 4 A304 [Fault history 4] - latest fault is automatically stored in the H 1- [Fault history 1]. non - H A30 [Fault history ] - non - H 6 A306 [Reset fault history] 0~1 Clears the fault history saved in H O When run frequency is issued, motor starts to accelerate after H 7 A307 [Dwell frequency] 0.1~400 [Hz] dwell frequency is applied to the motor during H8- [Dwell time]. [Dwell frequency] can be set within the range of F21- [Max.0 frequency] and F23- [Start frequency]. H 8 A308 [Dwell time] 0~10 [sec] Sets the time for dwell operation. 0. H10 A30A [Skip frequency 0 ~ 1 select] Sets the frequency range to skip to prevent undesirable resonance and vibration on the structure of the machine. H11 1) A30B [Skip frequency low limit 1] 10.0 H12 A30C [Skip frequency high limit 1].0 H13 A30D [Skip frequency low limit 2] 0.1~400 Run frequency cannot be set within the range of H11 thru H16. The frequency values of the low numbered parameters cannot 20.0 H14 A30E [Skip frequency high limit 2] [Hz] be set above those of the high numbered ones. Settable within the range of F21 and F H A30F [Skip frequency low limit 3] 30.0 H16 A310 [Skip frequency high limit 3] 3.0 H17 A311 [S-Curve accel/ 1~100 decel start side] [%] Set the speed reference value to form a curve at the start during accel/decel. If it is set higher, linear zone gets smaller. 4 H18 A312 [S-Curve accel/ 1~100 decel end side] [%] Set the speed reference value to form a curve at the end during accel/decel. If it is set higher, linear zone gets smaller. 4 [Input/output 0 Disabled 1 Output phase protection H19 A313 phase loss 0 ~ 3 protection select] 2 Input phase protection 3 Input/output phase protection 0 O This parameter is activated when drv is set to 1 or 2 (Run/Stop H20 A314 [Power On Start select] 0 ~ 1 via Control terminal). Motor starts acceleration after AC power is applied while FX or 0 O RX terminal is ON. H21 [Restart after A3 fault reset 0 ~1 selection] This parameter is activated when drv is set to 1 or 2 (Run/Stop via Control terminal). Motor accelerates after the fault condition is reset while the FX or RX terminal is ON. 0 O 1) only displayed when H10 is set to 1. # H17, H18 are used when F2, F3 are set to 1 (S-curve) 30

31 Compact & Powerful Drive iga Function group 2 LED display 1) H22 H23 H24 H2 H26 H27 H30 H31 Address for communication A316 A317 A318 A319 A31A A31B A31E A31F Parameter name [Speed Search Select] [Current level during Speed search] [P gain during Speed search] [I gain during speed search] [Number of Auto Restart try] Min/Max range 0 ~ 80~200 [%] 0~9999 0~ ~10 [Auto Restart 0~60 time] [Motor type select] [Number of motor poles] This parameter is active to prevent any possible fault when the drive outputs its voltage to the running motor. This parameter limits the amount of current during speed search. The set value is the percentage of the H33- [Motor rated current]. It is the Proportional gain used for Speed Search PI controller. It is the Integral gain used for Speed search PI controller. This parameter sets the number of restart tries after a fault occurs. Auto Restart is deactivated if the fault outnumbers the restart tries. This function is active when [drv] is set to 1 or 2 {Run/Stop via control terminal}. Deactivated during active protection function (OHT, LVT, EXT, HWT etc.). This parameter sets the time between restart tries. This setting is displayed via rpm in drive group. 1) Normal acceleration has first priority. Even though #4 is selected along with other bits, Drive performs Speed search #4. 2) H30 is preset based on drive rating. [sec] 0.2~ ~ H20-2. Restart 3. Operation 4. Normal [Power after instant after fault accel On start] power failure H20-2. Restart 3. Operation 4. Normal [Power after instant after fault accel On start] power failure Bit 3 Bit 2 Bit 1 Bit kW ~ ~ kW Factory defaults Adj. during run 0 O 100 O 100 O 200 O 0 O 1.0 O 2) 7. X 4 X Drive Starvert iga Series 31

32 iga Function List Function group 2 LED display Address for communication Parameter name Min/Max range Factory defaults Adj. during run H32 A320 [Rated slip 0 ~ 10 frequency] [Hz] rpm X p fs = fr -[ 120 ] Where, fs = Rated slip frequency fr = Rated frequency rpm = Motor nameplate RPM p = Number of Motor poles 1) 2.33 X H33 H34 H36 H37 H39 H40 H41 H42 H44 2) H4 H46 H47 H48 H49 A321 A322 A324 [Motor rated 0.~0 current] 1) H32 ~ H36 factory default values are set based on OTIS-LG motor. 2) Set H40 to 3 (Sensorless vector control) to display this parameter. [A] [No Load Motor 0.1~ 0 Current] [A] [Motor efficiency] 0~100 [%] A32 [Load inertia rate] 0 ~ 2 A327 A328 [Carrier frequency select] [Control mode select] 1 ~ [khz] 0 ~ 3 A329 [Auto tuning] 0 ~ 1 A32A A32C A32D A32E A32F A330 [Stator resistance 0 ~ 28 (Rs)] [Ω] [Leakage 0~ inductance (Lσ )] [mh] [Sensorless P gain] [Sensorless 0~ I gain] [Sensorless 100~220 torque limit] [%] PWM mode select 0~1 A331 PID select 0~1 Enter motor rated current on the nameplate. Enter the current value detected when the motor is rotating in rated rpm after the load connected to the motor shaft is removed. Enter the 0% of the rated current value when it is difficult to measure H34 - [No Load Motor Current]. Enter the motor efficiency (see motor nameplate). Select one of the following according to motor inertia. 0 Less than 10 times 1 About 10 times 2 More than 10 times This parameter affects the audible sound of the motor, noise emission from the drive, drive temp, and leakage current. If the set value is higher, the drive sound is quieter but the noise from the drive and leakage current will become greater. 0 {Volts/frequency Control} 1 {Slip compensation control} 3 {Sensorless vector control} If this parameter is set to 1, it automatically measures parameters of the H42 and H44. This is the value of the motor stator resistance. This is leakage inductance of the stator and rotor of the motor. P gain for Sensorless control I gain for Sensorless control Limits output torque in sensorless mode. If you want to limit a drive leakage current, select 2 phase PWM mode. It has more noise in comparison to Normal PWM mode. 0 Normal PWM mode 1 2 phase PWM mode Selects whether using PID control or not 26.3 X 11 X 87 X 3 O - X - X 1000 O 100 O

33 Compact & Powerful Drive iga Function group 2 LED display 1) H0 H1 H2 H3 H4 H H6 H7 H8 H9 H60 H61 2) H62 H63 H64 H6 H66 H67 Address for communication Parameter name Min/Max range A332 [PID F/B select] 0 ~ 1 A333 A334 A33 A336 A337 A338 A339 A33A A33B A33C A33D A33E [P gain for PID] 0~ [%] [Integral time 0.1~32.0 for PID [sec] [Differential time 0 ~ 30.0 for PID (D gain)] [sec] [PID control mode select] [PID output frequency high limit] [PID output frequency low limit] [PID standard value select] PID control unit select PID Output Inverse [Self-diagnostic select] 0~1 0.1 ~ 400 [Hz] 0.1 ~ 400 [Hz] 0~4 0~1 0~1 0 ~ 3 [Sleep delay time] 0~2000[s] [Sleep frequency] 0~400[Hz] A33F [Wake up level] 0~100[%] A340 [KEB drive select] 0~1 A341 [KEB action 110~140 start level] [%] A342 [KEB action 110~14 stop level] [%] A343 [KEB action gain] 1~ Terminal I input (0 ~ 20 ma) 1 Terminal V1 input (0 ~ 10 V) This parameter sets the gains for the PID controller. Selects PID control mode 0 Normal PID control 1 Process PID control This parameter limits the amount of the output frequency through the PID control. The value is settable within the range of F21? [Max frequency] and F23 - [Start frequency]. Selects PID standard value. Standard value is indicated in ref of Drive group. 0 Loader digital setting 1 1 Loader digital setting 2 2 V1 terminal setting 2: 0~10V 3 I terminal setting: 0~20mA 4 Setting as a RS-48 communication Selects a unit of the standard value or feedback amount. 0 Frequency[Hz] 1 Percentage[%] Select the output direction of PID control. 0 No 1 Yes 0 Self-diagnostic disabled 1 IGBT fault/ground fault 2 Output phase short & open/ Ground fault 3 Ground fault (This setting is unable when more than 11kW) Sets a sleep delay time in PID drive. Sets a sleep frequency when executing a sleep function in PID control drive. You canʼt set more than Max. frequency(f21) Sets a wake up level in PID control drive. Sets KEB drive. Sets KEB action start level according to level. Sets KEB action stop level according to level. Sets KEB action gain. 1) Set H49 to 1 (PID control) to display this parameter. 2) Set H49 as a 1 3): it is indicated when setting H64(KEB drive select) as a 1 (KEB does not operate when cut power after loading ting input (about 10%). Factory defaults Adj. during run O 1.0 O 0.0 O O 0.0 O O 3.0 O Drive Starvert iga Series 33

34 iga Function List Function group 2 LED display Address for communication Parameter name Min/Max range Factory defaults Adj. during run H70 [Frequency A346 Reference for 0 ~ 1 Accel/Decel] 0 Based on Max freq (F21) 1 Based on Delta freq. H71 H72 H73 H74 H7 A347 A348 A349 A34A [Accel/Decel time scale] [Power on display] [Monitoring item select] 0 ~ 2 0 ~ 0 ~ 2 [Gain for Motor 1 ~ 1000 rpm display] [%] [DB resistor A34B operating rate 0 ~ 1 limit select] 0 Settable unit: 0.01 second. 1 Settable unit: 0.1 second. 2 Settable unit: 1 second. This parameter selects the parameter to be displayed on the keypad when the input power is first applied. 0 Frequency command 1 Accel time 2 Decel time 3 Drive mode 4 Frequency mode Multi-Step frequency 1 6 Multi-Step frequency 2 7 Multi-Step frequency 3 8 Output current 9 Motor rpm 10 Drive DC link voltage 11 User display select (H73) 12 Fault display 13 Direction of motor rotation select 14 Output current 2 Motor rpm 2 16 Drive DC link voltage 2 17 User display select 2 One of the following can be monitored via vol - [User display select]. 0 Output voltage [V] 1 Output power [kw] 2 Torque [kgf, m] This parameter is used to change the motor rotating speed (r/ min) to mechanical speed (m/mi) and display it. 0 Unlimited 1 Use DB resistor for the H76 set time. 1 O 0 O 0 O 100 O 1 O H76 H77 1) A34C A34D [DB resistor 0 ~ 30 operating rate] [%] [Cooling fan control] 0 ~ 2 Set the percent of DB resistor operating rate to be activated during one sequence of operation. 0 Always ON Keeps ON when its temp is higher than drive protection 1 limit temp. Activated only during operation when its temp is below that of drive protection limit. Regardless of the operation fan is active when is temp is 2 higher than drive protection limit temp. 10 O 0 O 1) Exception: Since SV004iGA-2/SV004iGA-4 is Natural convection type, this code is hidden. 34

35 Compact & Powerful Drive iga Function group 2 LED display Address for communication Parameter name Min/Max range Factory defaults Adj. during run H78 H79 H81 1) H82 H83 H84 H8 H86 H87 H88 H89 H90 H91 2) H92 H93 H94 H9 A34E [Operating method select when cooling fan malfunctions] 0 ~ 1 A34F [S/W version] 0 ~ 10.0 A31 A32 A33 A34 A3 A36 A347 A38 A39 A3A [2 nd motor Accel time] 0 ~ 6000 [2 nd motor [sec] Decel time] [2 nd motor 30 ~ 400 base frequency] [2 nd motor V/F pattern] [2 nd motor forward [Hz] 0 ~ 2 torque boost] 0 ~ [2 nd motor reverse [%] torque boost] [2 nd motor stall 30~0 prevention level] [%] [2 nd motor Electronic thermal level for 1 min] [2 nd motor 0~200 [%] Electronic 0~0 thermal level for [%] continuous] [2 nd motor 0.1~100 rated current] [A] A3B [Parameter read] 0 ~ 1 A3C [Parameter write] 0 ~ 1 A3D A3E [Parameter initialize] [Password register] 0 ~ 0 ~ FFFF A3F [Parameter lock] 0 ~ FFFF 0 Continuous operation when cooling fan malfunctions. 1 Operation stopped when cooling fan malfunctions. This parameter displays the drive software version. This parameter actives when the selected terminal is ON after I17-I24 is set to 12 {2 nd motor select}. Copy the parameters from drive and save them into remote loader. Copy the parameters from remote loader and save them into drive. This parameter is used to initialize parameters back to the factory default value. 0-1 All parameter groups are initialized to factory default value. 2 Only Drive group is initialized. 3 Only Function group 1 is initialized. 4 Only Function group 2 is initialized. Only I/O group is initialized. Password for H9-[Parameter lock]. Set as Hexa value. This parameter is able to lock or unlock parameters by typing password registered in H94. UL (Unlock) Parameter change enable L (Lock) Parameter change disable 0 O 1..0 O 10.0 O 60.0 X X 0 O 100 O 26.3 X 0 O 0 O 1) It is indicated when choosing I17~I24 as a 12 (2nd motor select). 2) H91,H92 parameters are displayed when Remote option is installed. Drive Starvert iga Series 3

ig5a 0.4~1.5kW (0.5~2HP) 1phase 200~230Volts 0.4~22kW (0.5~30HP) 3Phase 200~230Volts 0.4~22kW (0.5~30HP) 3Phase 380~480Volts Compact & Powerful Drive

ig5a 0.4~1.5kW (0.5~2HP) 1phase 200~230Volts 0.4~22kW (0.5~30HP) 3Phase 200~230Volts 0.4~22kW (0.5~30HP) 3Phase 380~480Volts Compact & Powerful Drive Compact & Powerful Drive iga ~1.kW (0.~2HP) 1phase 200~230Volts ~22kW (0.~30HP) 3Phase 200~230Volts ~22kW (0.~30HP) 3Phase 380~480Volts Drive Starvert iga LS Starvert iga is very competitive in its price

More information

Compact & Powerful Inverter STARVERT ig5a 0.4~1.5kW 1phase 200~230Volts 0.4~22kW 3Phase 200~230Volts 0.4~22kW 3Phase 380~480Volts

Compact & Powerful Inverter STARVERT ig5a 0.4~1.5kW 1phase 200~230Volts 0.4~22kW 3Phase 200~230Volts 0.4~22kW 3Phase 380~480Volts Compact & Powerful Inverter STARVERT ig5a 0.4~1.5kW 1phase 200~230Volts 0.4~22kW 3Phase 200~230Volts 0.4~22kW 3Phase 380~480Volts Inverter STARVERT ig5a LS Starvert ig5a is very competitive in its price

More information

SAFETY INSTRUCTIONS WARNING

SAFETY INSTRUCTIONS WARNING Important User Information Thank you for purchasing LS Variable Frequency Drives! SAFETY INSTRUCTIONS Always follow safety instructions to prevent accidents and potential hazards from occurring. In this

More information

GS S. Compact Space Ve VFD. Frequency and .5 5

GS S. Compact Space Ve VFD. Frequency and .5 5 GS S Compact Space Ve VFD Frequency and.55.55 8 Thank you for purchasing CERUS Variable Frequency Drives! SAFETY INSTRUCTIONS Always follow safety instructions to prevent accidents and potential hazards

More information

SAFETY INSTRUCTIONS. Always follow safety instructions to prevent accidents and potential hazards from occurring.

SAFETY INSTRUCTIONS. Always follow safety instructions to prevent accidents and potential hazards from occurring. 1 Thank you for purchasing LS Variable Frequency Drives! SAFETY INSTRUCTIONS Always follow safety instructions to prevent accidents and potential hazards from occurring. In this manual, safety messages

More information

STARVERT ig5a. Compact & Powerful Inverter. 0.4~7.5kW 3Phase 200~230Volts 0.4~7.5kW 3Phase 380~480Volts. Automation Equipment

STARVERT ig5a. Compact & Powerful Inverter. 0.4~7.5kW 3Phase 200~230Volts 0.4~7.5kW 3Phase 380~480Volts. Automation Equipment Leader in Electrics & Automation STARVERT iga Compact & Powerful Inverter.4~7.kW 3Phase 2~23Volts.4~7.kW 3Phase 38~48Volts Automation Equipment Inverter STARVERT iga LS Starvert iga is very competitive

More information

SAFETY INSTRUCTIONS. Always follow safety instructions to prevent accidents and potential hazards from occurring.

SAFETY INSTRUCTIONS. Always follow safety instructions to prevent accidents and potential hazards from occurring. Thank you for purchasing LS Variable Frequency Drives! SAFETY INSTRUCTIONS Always follow safety instructions to prevent accidents and potential hazards from occurring. In this manual, safety messages are

More information

LG Variable Frequency Drive

LG Variable Frequency Drive LG Variable Frequency Drive ig5 Series 0.5-5.4HP (200/400V) Installation, Operation and Maintenance Instruction Read this manual carefully before installing, wiring, operating, servicing or inspecting

More information

WorldDrive General Purpose VFD The WDGP: Operation and Instructional Manual

WorldDrive General Purpose VFD The WDGP: Operation and Instructional Manual WorldDrive General Purpose VFD The WDGP: Operation and Instructional Manual WorldWide Electric Corp. 3540 Winton Place Rochester, NY 14623 Phone: (800) 808-2131 Fax: (800) 711-1616 www.worldwideelectric.net

More information

USER MANUAL -Installation and Programming Instructions-

USER MANUAL -Installation and Programming Instructions- 15P0073B1 SERIES M VARIABLE FREQUENCY DRIVE FULL DIGITAL INVERTER USER MANUAL -Installation and Programming Instructions- Issued on 14/05/09 R.02 SW Ver. EU2.2 English This manual is integrant and essential

More information

Variable Speed Drive. User's Manual

Variable Speed Drive. User's Manual Variable Speed Drive User's Manual VARIABLE SPEED DRIVE User s Manual SD10MT01BI Rev. B POWER ELECTRONICS ESPAÑA C/ Leonardo da Vinci, 24-26 PARQUE TECNOLOGICO 46980 PATERNA VALENCIA ESPAÑA Atención al

More information

15P0073B1. Inverter SINUS M USER MANUAL. Eng lish

15P0073B1. Inverter SINUS M USER MANUAL. Eng lish 15P0073B1 Inverter SINUS M USER MANUAL Update 04/12/05 R. 00 Eng lish This manual is integrant and essential to the product. Carefully read the instructions contained herein as they provide important hints

More information

Safety Instructions WARNING. Do not remove the cover while power is applied or the unit is in operation.

Safety Instructions WARNING. Do not remove the cover while power is applied or the unit is in operation. Thank you for purchasing L&T inverter! Safety Instructions Read this manual carefully before installing, wiring, operating, servicing or inspecting this equipment. The safety instructions are divided into

More information

IC5 Series. LG Variable Frequency Drive 1/2-3 HP (230V) LG Industrial SystemsG. Installation, Operation and Maintenance Instruction

IC5 Series. LG Variable Frequency Drive 1/2-3 HP (230V) LG Industrial SystemsG. Installation, Operation and Maintenance Instruction LG Variable Frequency Drive IC5 Series GGGGGGG G G G G G G G G GGGGGGG 1/2-3 HP (230V) GGGGGGGGGGGGGGGGGGGGGGGG G G G G GGGGGGG G G Installation, Operation and Maintenance Instruction G G G G G G G G G

More information

Warning!! 2. The drive contains high voltage that can cause electric shock resulting in personal injury or loss of life.

Warning!! 2. The drive contains high voltage that can cause electric shock resulting in personal injury or loss of life. ! Warning!! 1. Please read this manual completely before installing the drive. 2. The drive contains high voltage that can cause electric shock resulting in personal injury or loss of life. 3. Be sure

More information

Variable Frequency Drive / Inverter (0.4 ~ 280kW)

Variable Frequency Drive / Inverter (0.4 ~ 280kW) Variable Frequency Drive / Inverter (0.4 ~ 280kW) & Standard Features Configuration Comparison Comparison Table Enclosure IP00 IP20 NEMA 1 Rating Single phase 0.4 2.2kW 0.4 1.5kW Three phase 0.4 4kW Constant

More information

SAFETY INSTRUCTIONS. After reading this manual, keep it in the place that the user always can contact easily.

SAFETY INSTRUCTIONS. After reading this manual, keep it in the place that the user always can contact easily. Thank you for purchasing LS Variable Frequency Drives! SAFETY INSTRUCTIONS To prevent injury and property damage, follow these instructions. Incorrect operation due to ignoring instructions will cause

More information

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE 1 2 SERIES 1 2 pag. 4 pag. 5 Applications Model identification 3 pag. 5 4 pag. 6 Capacity

More information

GS1 Parameter Summary Detailed Parameter Listings...4 9

GS1 Parameter Summary Detailed Parameter Listings...4 9 CHAPTER AC DRIVE 4 PARAMETERS Contents of this Chapter... GS1 Parameter Summary...............................4 2 Detailed Parameter Listings..............................4 9 Motor Parameters.........................................4

More information

SAFETY INSTRUCTIONS. To prevent injury and property damage, follow these instructions during the installation and operation of the inverter.

SAFETY INSTRUCTIONS. To prevent injury and property damage, follow these instructions during the installation and operation of the inverter. Thank you for purchasing LS Variable Frequency Drives! SAFETY INSTRUCTIONS To prevent injury and property damage, follow these instructions during the installation and operation of the inverter. Incorrect

More information

CHAPTER AC DRIVE PARAMETERS. In This Chapter...

CHAPTER AC DRIVE PARAMETERS. In This Chapter... CHAPTER AC DRIVE 4 PARAMETERS In This Chapter... GS2 Parameter Summary....................4 2 Detailed Parameter Listings.................4 11 Motor Parameters........................4 11 Ramp Parameters.........................4

More information

TOSVERT TM VF-nC3 Parameter List

TOSVERT TM VF-nC3 Parameter List TOSVERT TM VF-nC Parameter List E658664 - Setting information * Please fill it in if necessary. Item Content Item Content Setting date / person Customer Application Application model Motor manufacturer

More information

Starvert ig5a. Compact & Powerful Inverter. 0.4~1.5kW 1phase 200~230Volts 0.4~22kW 3Phase 200~230Volts 0.4~22kW 3Phase 380~480Volts

Starvert ig5a. Compact & Powerful Inverter. 0.4~1.5kW 1phase 200~230Volts 0.4~22kW 3Phase 200~230Volts 0.4~22kW 3Phase 380~480Volts Compact & Powerful Inverter Starvert ig5a.4~1.5kw 1phase ~3Volts.4~kW 3Phase ~3Volts.4~kW 3Phase 38~48Volts Automation Equipment Inverter STARVERT ig5a LS Starvert ig5a is very competitive in its price

More information

Variable Frequency Drive ic kW 1 Phase Volts

Variable Frequency Drive ic kW 1 Phase Volts www.lsis.com Variable Frequency Drive ic5 0.4-2.2kW 1 Phase 200-230Volts ' 1:Vla.' ıı ' _J_ ------.. 6.WARNIHG ------- - --...-.,_, - ---- -.. -- ---- --..--- ---- -- - r... o.drie---. ---- ı II Global

More information

Global standard ic5, serves a wide variety of applications to meet the majority of user needs.

Global standard ic5, serves a wide variety of applications to meet the majority of user needs. Global standard ic5, serves a wide variety of applications to meet the majority of user needs. Modbus communication PID control Sensorless vector control Motor parameter auto tuning Models 05 Wiring 07

More information

This operation manual is intended for users with basic knowledge of electricity and electric devices.

This operation manual is intended for users with basic knowledge of electricity and electric devices. This operation manual is intended for users with basic knowledge of electricity and electric devices. Safety Information Safety Information Read and follow all safety instructions in this manual precisely

More information

ADJUSTABLE SPEED DRIVES VF-S11 Sords Electric

ADJUSTABLE SPEED DRIVES VF-S11 Sords Electric ADJUSTABLE SPEED DRIVES VF-S11 The Next Generation of Micro Inverters is Here. The S11 provides maximum torque with precise speed control. It features an easy-to-use, quiet and compact design. In addition,

More information

Industrial Inverter for Fan and Pump. STARVERT ip5a. 5.5~30kW(7.5~40HP) 3Phase 200~230Volts 5.5~450kW(7.5~600HP) 3Phase 380~480Volts.

Industrial Inverter for Fan and Pump. STARVERT ip5a. 5.5~30kW(7.5~40HP) 3Phase 200~230Volts 5.5~450kW(7.5~600HP) 3Phase 380~480Volts. Industrial Inverter for Fan and Pump STARVERT ip5a 5.5~30kW(7.5~40HP) 3Phase 200~230Volts 5.5~450kW(7.5~600HP) 3Phase 380~480Volts Drive Solution STARVERT ip5a LS Starvert ip5a is basically created for

More information

Elettronica Santerno is responsible for the information contained in the original version of the Italian manual.

Elettronica Santerno is responsible for the information contained in the original version of the Italian manual. 15P0087B5 VEGA DRIVE SPACE VECTOR CONTROL UPD. 09/10/02 R. 01 English This manual is integrant and essential to the product. Carefully read the instructions contained herein as they provide important hints

More information

WARNING CAUTION. Fire Prevention. Electrical Shock Prevention. Damage Prevention

WARNING CAUTION. Fire Prevention. Electrical Shock Prevention. Damage Prevention ! WARNING! CAUTI Electrical Shock Prevention 1. Do not remove the front cover when input power is applied. Doing so can result in electric shock. 2. Do not operate the inverter with the front cover removed.

More information

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps. VFD - D700 Series Specifications The latest low-cost variable speed control solution for centrifugal pumps. Built-in PID Control to maintain pressure, flow, measured value, and much more 125% overload

More information

SJ100 Series Inverter Quick Reference Guide. Single-phase Input 200V Class Three-phase Input 200V Class Three-phase Input 400V Class

SJ100 Series Inverter Quick Reference Guide. Single-phase Input 200V Class Three-phase Input 200V Class Three-phase Input 400V Class HITACHI SJ1 Series Inverter Quick Reference Guide Single-phase Input 2V Class Three-phase Input 2V Class Three-phase Input 4V Class Hitachi Industrial Equipment Systems Co., Ltd. Manual No. NB5821XD Dec.

More information

TECHNICAL SPECIFICATION INVERTER VEGA DRIVE

TECHNICAL SPECIFICATION INVERTER VEGA DRIVE TECHNICAL SPECIFICATION INVERTER VEGA DRIVE ELETTRONICA SANTERNO Contents Overview 3 Features & selection guide 4/5 Data sheet 6/7 Wiring & connection terminals 8/9 Keypad & parameters navigation 10/11

More information

Fan and Pump AC Inverter

Fan and Pump AC Inverter Fan and Pump AC Inverter Key Features for Fan and Pump Applications PID and Auto Energy Saving Functions. Input Phase Loss and Output Phase Loss Protection. LCD Keypad can be used to copy parameter settings

More information

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection Quick Start Guide TECO F510 Inverter This guide is to assist you in installing and running the inverter and verify that it is functioning correctly for it s main and basic features. For detailed information

More information

CHAPTER 8 PARAMETER SUMMARY

CHAPTER 8 PARAMETER SUMMARY CHAPTER PARAMETER SUMMARY Group 0: System Parameter VFD-V Series 00-00 Identity Code Based on the model type 00-01 Rated Current Display 00-02 Parameter Reset 00-03 00-04 Star-up Display of the Drive Definitions

More information

P-SERIES VFD 1-40HP (200~230VAC), 1-400HP (380~480VAC),3Ø Dual Rated for Constant & Variable Torque Integrated PID Control

P-SERIES VFD 1-40HP (200~230VAC), 1-400HP (380~480VAC),3Ø Dual Rated for Constant & Variable Torque Integrated PID Control P-SERIES VFD 1-40HP (200~230VAC), 1-400HP (380~480VAC),3Ø Dual Rated for Constant & Variable Torque Integrated PID Control NEW FIRMWARE MAKES SETUP A SNAP Application based commissioning allows parameters

More information

HITACHI. L100-M Series Inverter Quick Reference Guide. Hitachi Industrial Equipment Systems Co., Ltd. Single-phase Input 100V Class

HITACHI. L100-M Series Inverter Quick Reference Guide. Hitachi Industrial Equipment Systems Co., Ltd. Single-phase Input 100V Class HITACHI L1-M Series Inverter Quick Reference Guide Single-phase Input 1V Class Hitachi Industrial Equipment Systems Co., Ltd. Manual No. NB5741XD December 23 Caution: Be sure to read the L1 Inverter Manual

More information

High on efficiency big on reliability AC Drive for Fans & Pumps

High on efficiency big on reliability AC Drive for Fans & Pumps High on efficiency big on reliability AC Drive for Fans & Pumps Three Phase 415V (5.5 ~ 450kW) Two decades of application knowledge For over two decades, various industry sectors have been reaping the

More information

Thank you for purchasing FCS (Franklin Control Systems former Cerus) VFD SAFETY INSTRUCTIONS

Thank you for purchasing FCS (Franklin Control Systems former Cerus) VFD SAFETY INSTRUCTIONS Thank you for purchasing FCS (Franklin Control Systems former Cerus) VFD SAFETY INSTRUCTIONS To prevent injury and property damage, follow these instructions during the installation and operation of VFD.

More information

P Series. Installation, Programming Operation, & Maintenance Manual. Fan & Pump Optimized Variable Frequency Drive.

P Series. Installation, Programming Operation, & Maintenance Manual. Fan & Pump Optimized Variable Frequency Drive. I n t e l l i g e n t M o t o r C o n t r o l s P Series Fan & Pump Optimized Variable Frequency Drive P Series Manual 0.5 40HP (200~230VAC), 3Ø 0.5 700HP (380~480VAC), 3Ø 0.5-150HP (525~600VAC), 3Ø Dual

More information

Variable Speed Drive Getting Started Manual

Variable Speed Drive Getting Started Manual Variable Speed Drive Getting Started Manual Variable speed drive Getting Started Manual Edition: October 2012 SD25IM02AI Rev. A SD250 - DEVICENET POWER ELECTRONICS 2 POWER ELECTRONICS SD250 SAFETY SYMBOLS

More information

Manual Overview...1 2

Manual Overview...1 2 GETTING STARTED CHAPTER 1 Contents of this Chapter... Manual Overview.....................................1 2 Overview of this Publication..................................1 2 Who Should Read This Manual...............................1

More information

6.9 Jump frequency - Avoiding frequency resonance

6.9 Jump frequency - Avoiding frequency resonance E581595.9 Jump frequency - Avoiding frequency resonance : Jump frequency : Jumping width Function Resonance due to the natural frequency of the mechanical system can be avoided by jumping the resonant

More information

S11 Adjustable Speed Drive Engineering Specification

S11 Adjustable Speed Drive Engineering Specification PART 1 - GENERAL 1.0 Scope This specification shall cover Toshiba S11 AC Variable Frequency Drives, 6 pulse for 3- phase 200-240VAC, 380-500VAC and single phase 200V to 240VAC. 1.1 References A. National

More information

AV-300i Specifications. Saftronics Inc. VG10 Product Specifications VG10. Dynamic Vector Drive

AV-300i Specifications. Saftronics Inc.   VG10 Product Specifications VG10. Dynamic Vector Drive Saftronics Inc. www.saftronics.com TM AV-300i Specifications VG10 Product Specifications VG10 Dynamic Vector Drive 1 Category Item Description Nominal Motor 230 VAC, 3 Phase 1/4 Hp to 125 Hp 460 VAC, 3

More information

AV-300i Specifications. Saftronics Inc. PC10 Product Specifications PC10. Mini Vector AC Drive

AV-300i Specifications. Saftronics Inc.  PC10 Product Specifications PC10. Mini Vector AC Drive Saftronics Inc. www.saftronics.com TM AV-300i Specifications PC10 Product Specifications PC10 Mini Vector AC Drive 1 (1) T hree-phas e 230V input Drive Hp 1/8 1/4 1/2 1 2 3 5 7.5 10 Nominal applicable

More information

ADJUSTABLE SPEED DRIVES. AS1 Drive

ADJUSTABLE SPEED DRIVES. AS1 Drive ADJUSTABLE SPEED DRIVES AS1 Drive Toshiba s New ASD Product Line The AS1 drive builds on Toshiba s history of supplying powerful, reliable, and versatile drives. We have combined our best drive features

More information

ADJUSTABLE SPEED DRIVES FS1

ADJUSTABLE SPEED DRIVES FS1 ADJUSTABLE SPEED DRIVES FS1 Now Available With LonWorks BACnet & MetasysN2 FS1 Model FLA & Dimensions (in.)/ Weight (lbs.) VOLTAGE HP MODEL NUMBER FLA FRAME Dimensions (in.) SHIPPING H W D WEIGHT (lbs.)

More information

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13 Index A A Group functions 3 9 AC reactors 5 3 Acceleration 1 15, 3 8 characteristic curves 3 26 second function 3 24 two-stage 4 19 Acceleration stop function 3 21 Access levels 3 5, 3 36, 4 25 Access

More information

General Specifications FECA-TE /2010. Phone: Fax: Web:

General Specifications FECA-TE /2010. Phone: Fax: Web: General Specifications FECA-TE-117 06/2010 1. Standard Specifications 1) Three-phase 230V series Output ratings Input ratings Braking Item Specifications Type (FRN C1S-2U) F12 F25 F50 001 002 003 005 Nominal

More information

D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL

D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL D SERIES LM16 COMPACT DRIVE V/f and SLV CONTROL LM16 COMPACT DRIVE V/f and SLV CONTROL 1 2 SERIES 1 2 page 4 page 6 Introduction Fields of application 3 page 7 4 page 8 Designation Product offer 5 6 page

More information

KBDA SERIES STANDARD FEATURES DESCRIPTION PERFORMANCE FEATURES PROTECTION FEATURES

KBDA SERIES STANDARD FEATURES DESCRIPTION PERFORMANCE FEATURES PROTECTION FEATURES KBDA SERIES ADJUSTABLE FREQUENCY DRIVES FOR 3-PHASE AC MOTORS NEMA-4X / IP-65 Washdown and Watertight for Indoor and Outdoor use MULTI-FUNCTION KEYPAD WITH 4-DIGIT LED DISPLAY Simplified Group Programming

More information

AF91 Adjustable Frequency Drives Series B

AF91 Adjustable Frequency Drives Series B Effective: January, 00 Page New Information AF9 Adjustable Model AF9 Description Model AF9 Adjustable Frequency AC Drives are designed to provide adjustable speed control of -phase motors. These microprocessor-based

More information

VS1SM Single Phase AC Drive

VS1SM Single Phase AC Drive VS1SM Single Phase AC Drive 10/07 Installation & Operating Manual MN761 Any trademarks used in this manual are the property of their respective owners. Important: Be sure to check www.baldor.com for the

More information

Inverter Drive /Vector Drive Motors & Controls

Inverter Drive /Vector Drive Motors & Controls H2 Inverter/ Encoderless Vector Inverter Drive /Vector Drive & Controls 3/4 thru 50 180-264 VAC 3 Phase - 50/60 Hz 3/4 thru 60 340-528 VAC 3 Phase - 50/60 Hz 3/4 thru 60 515-660 VAC 3 Phase - 60 Hz HVAC

More information

VF-nC1 Adjustable Speed Drive Engineering Specification

VF-nC1 Adjustable Speed Drive Engineering Specification PART 1 - GENERAL 1.0 Scope This specification shall cover Toshiba VF-nC1 AC Variable Frequency Drives, 6 pulse for 100V single-phase 0.1 to 0.75kW, 200V single-phase 0.2 to 2.2kW and 200V threephase 0.1

More information

NX series Constant and variable torque Variable Speed Drives for induction motors

NX series Constant and variable torque Variable Speed Drives for induction motors Honeywell All in One Application Manual NX series Constant and variable torque Variable Speed Drives for induction motors Subject to changes without notice CONTENTS NX "All in One" APPLICATION MANUAL INDEX

More information

Thank you for purchasing Marathon Drive Variable Frequency Drives! SAFETY INSTRUCTIONS

Thank you for purchasing Marathon Drive Variable Frequency Drives! SAFETY INSTRUCTIONS Safety Instructions Thank you for purchasing Variable Frequency Drives! SAFETY INSTRUCTIONS To prevent injury and property damage, follow these instructions during the installation and operation of the

More information

INTERNATIONAL SERVICE BULLETIN - I #2-319 Liberty - Delta M+ VFD parameter list. A VFD parameter list is required when replacing a DELTA M+ VFD.

INTERNATIONAL SERVICE BULLETIN - I #2-319 Liberty - Delta M+ VFD parameter list. A VFD parameter list is required when replacing a DELTA M+ VFD. RYKO Manufacturing Company 116 N.W. 54th Ave. P.O.Box 38 Grimes, Iowa 5111 Phone (515) 986-37 www.ryko.com Fax (515) 986-3621 sales@ ryko.com INTERNATIONAL SERVICE BULLETIN - I #2-319 Liberty - Delta M+

More information

Multi-function, Compact Inverters. 3G3MV Series

Multi-function, Compact Inverters. 3G3MV Series Multi-function, Compact Inverters 3G3MV Series There has been a great demand for inverters with more functions and easier motor control than conventional i OMRON's powerful, compact 3G3MV Series with versat

More information

Medium Voltage VFD. Perfect Energy Saving Drive 3kV 200kVA ~ 3,700kVA / 4kV 250kVA ~ 4,700kVA 6kV 400kVA ~ 7,500kVA / 10kV 600kVA ~ 11,000kVA

Medium Voltage VFD. Perfect Energy Saving Drive 3kV 200kVA ~ 3,700kVA / 4kV 250kVA ~ 4,700kVA 6kV 400kVA ~ 7,500kVA / 10kV 600kVA ~ 11,000kVA www.miepl.com/ls Medium Voltage VFD Perfect Energy Saving Drive 3kV 200kVA ~ 3,700kVA / 4kV 250kVA ~ 4,700kVA 6kV 400kVA ~ 7,500kVA / 10kV kva ~ 11,000kVA Perfect Energy Saving Drive The most efficiency

More information

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual INDEX A AC Drive Cover: 1 6 Dimensions: 2 4 External Parts and Labels: 1 6 Heat Sink Fins: 1 6 Input Mode Switch (Sink/Source): 1 6 Introduction to DuraPulse GS3 AC drive: 1 3 Keypad: 1 6 Model Number

More information

E3 Adjustable Speed Drive Engineering Specification

E3 Adjustable Speed Drive Engineering Specification E3 Adjustable Speed Drive Engineering Specification PART 1 - GENERAL 1.0 Scope This specification shall cover Toshiba E3 AC Variable Frequency Drives, 6 pulse for 230V and 460V. 1.1 References A. National

More information

CHAPTER 8 SUMMARY OF PARAMETER SETTINGS

CHAPTER 8 SUMMARY OF PARAMETER SETTINGS CHAPTER 8 SUMMARY OF PARAMETER SETTINGS VFD-S Series!: The parameter can be set during operation, *: Twice the value for 460V class. Group 0 User Parameters Parameters Explanation s 0-00 Identity Code

More information

VS-616PC5/P5 Series User s Manual

VS-616PC5/P5 Series User s Manual VS-616PC5/P5 Series User s Manual Variable Torque Inverter PRECAUTIONS! WARNING 1) Read this manual in its entirety before installing or operating the VS- 616PC5/P5 inverter. 2) Do not connect or disconnect

More information

Starvert ic5. Variable Frequency Drive / Inverter. Automation Equipment. Leader in Electrics & Automation

Starvert ic5. Variable Frequency Drive / Inverter. Automation Equipment. Leader in Electrics & Automation Leader in Electrics & Automation Variable Frequency Drive / Inverter Starvert ic5 0.4-2.2kW 1 phase 200-230Volts 0.4-0.75kW 3 phase 200-230Volts Automation Equipment Global standard ic5, serves a wide

More information

RSi SG Series Sensorless Vector Variable Frequency Drive

RSi SG Series Sensorless Vector Variable Frequency Drive RSi SG Series Sensorless Vector Variable Frequency Drive 7.5 to 40HP - 230V 7.5 to 700HP - 460V 7.5 to 150HP - 600V Instruction Manual 890046-00-01 2012 Benshaw Inc. Benshaw retains the right to change

More information

VFS11 Parameter List for up to CPU version 105

VFS11 Parameter List for up to CPU version 105 E65824 VFS Parameter List for up to CPU version 5 Setting Date Customer End user Application Application No/Serial No Inverter s Type-Form Quantity Inverter s Serial No Motor s capacity If user s value

More information

FUJI Inverter. Standard Specifications

FUJI Inverter. Standard Specifications FUJI Inverter o Standard Specifications Norminal applied motor The rated output of a general-purpose motor, stated in kw. That is used as a standard motor. Rated capacity The rating of an output capacity,

More information

Caution. Three-phase 400V series FRN0.4C1S-4A FRN0.75C1S-4A FRN1.5C1S-4A FRN2.2C1S-4A FRN3.7C1S-4A

Caution. Three-phase 400V series FRN0.4C1S-4A FRN0.75C1S-4A FRN1.5C1S-4A FRN2.2C1S-4A FRN3.7C1S-4A Variation Caution The contents of this catalog are provided to help you select the product model that is best for you. Before actual use, be sure to read the User s Manual thoroughly to assure correct

More information

VSC. Instruction Manual - English

VSC. Instruction Manual - English VSC Instruction Manual - English Quick Start Guide This guide is to assist in installing and running the inverter to verify that the drive and motor are working properly. Starting, stopping and speed control

More information

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3 CHAPTER INSTALLATION 2 AND WIRING Contents of this Chapter... Ambient Conditions..............................2 2 Storage Conditions...............................2 2 Installation.....................................2

More information

Optimum solution for small size motor control New micro size Drive 0.1~0.4kW 1Phase 200~230Volts 0.1~0.4kW 3Phase 200~230Volts

Optimum solution for small size motor control New micro size Drive 0.1~0.4kW 1Phase 200~230Volts 0.1~0.4kW 3Phase 200~230Volts www.lsis.com Optimum solution for small size motor control New micro size Drie.~.4kW Phase ~3Volts.~.4kW 3Phase ~3Volts Experience the power! 4 6 7 8 9 Key features of product Model and Specifications

More information

For additional PowerFlex 4 and 40 data and general drive information, refer to the following publications:

For additional PowerFlex 4 and 40 data and general drive information, refer to the following publications: Product Overview Providing users with powerful motor speed control in a compact, space saving design, the Allen-Bradley PowerFlex 4 and 40 AC drives are the smallest and most cost-effective members of

More information

The new Yaskawa Varispeed G7 Inverter

The new Yaskawa Varispeed G7 Inverter The new Yaskawa Varispeed G7 Inverter Unique new 3-level PWM flux vector Constant or variable torque applications control method 0.4 kw to 300 kw power range Exceptional low speed/high torque control Quick

More information

vacon nx all in one application manual ac drives Phone: Fax: Web: -

vacon nx all in one application manual ac drives Phone: Fax: Web:  - vacon nx ac drives all in one application manual vacon 1 INDEX Document ID:DPD00903A Revision release date: 30.3.2012 1. Basic Application...5 1.1. Introduction...5 1.1.1. Motor protection functions in

More information

Emotron VSA Variable Speed Drive

Emotron VSA Variable Speed Drive Emotron VSA Variable Speed Drive Instruction manual English Quick Start Guide This guide is designed to assist in installing and running the variable speed drive to verify that the drive and motor are

More information

HPVFP High Performance Full Function Vector Frequency Inverter

HPVFP High Performance Full Function Vector Frequency Inverter Advanced User Manual HPVFP High Performance Full Function Vector Frequency Inverter HP VER 1.00 1. HPVFP Parameter Set Overview...3 1.1. About this section...3 1.2. Parameter Structure Overview...3 1.3.

More information

L100-M Series Inverters

L100-M Series Inverters L100-M Series Inverters Addendum to L100 Series Inverter Instruction Manual In This Addendum... page Getting Started... 3 Inverter Mounting and Installation... 10 Configuring Drive Parameters... 15 Operations

More information

QUick StARt guide. Customised to your machine Model: 3G3RX 200 V Class Three-Phase Input 0.4 to 55 kw 400 V Class Three-Phase Input 0.

QUick StARt guide. Customised to your machine Model: 3G3RX 200 V Class Three-Phase Input 0.4 to 55 kw 400 V Class Three-Phase Input 0. Cat. No. I130E-EN-02 RX Customised to your machine Model: 3G3RX 200 V Class Three-Phase Input 0.4 to 55 kw 400 V Class Three-Phase Input 0.4 to 132 kw QUick StARt guide Notice: OMRON Product References

More information

SV9000 SVReady USER MANUAL CONTENTS OPEN SV9000 USER MANUAL. SV9000 Page 0-1

SV9000 SVReady USER MANUAL CONTENTS OPEN SV9000 USER MANUAL. SV9000 Page 0-1 SV9000 Page 0-1 SV9000 SVReady USER MANUAL CNTENTS A General...0-2 B Application selection...0-2 C Restoring default values of application parameters...0-2 D Language selection...0-2 1 Standard Control

More information

BOSTON GEAR CONTROLLERS. ACE 20 Series 1/8 through 10 HP Adjustable Frequency AC Motor Controllers. MTY (81)

BOSTON GEAR CONTROLLERS. ACE 20 Series 1/8 through 10 HP Adjustable Frequency AC Motor Controllers. MTY (81) BOSTON GEAR CONTROLLERS ACE 20 Series 1/8 through 10 HP Adjustable Frequency AC Motor Controllers ACE 20 Series Offering full-featured control in high torque, low speed applications from 1/8 to 10 HP,

More information

SYSDRIVE 3G3XV Inverter 3G3XV- -EV2 Operation Manual

SYSDRIVE 3G3XV Inverter 3G3XV- -EV2 Operation Manual SYSDRIVE 3G3XV Inverter 3G3XV- -EV2 Operation Manual Revised November 1997 iv Notice: OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes

More information

Operation Instructions NORDAC SK 400E. Frequency Inverter. SK 400E B / SK 400E B (0.4kW / 0.7kW, 1~ 115V)

Operation Instructions NORDAC SK 400E. Frequency Inverter. SK 400E B / SK 400E B (0.4kW / 0.7kW, 1~ 115V) NORDAC SK4E Safety Instructions Operation Instructions NORDAC SK 4E Frequency Inverter SK 4E-2-111-B / SK 4E-4-111-B (.4kW /.7kW, 1~ 115V) SK 4E-2-123-B... SK 4E-151-323-B (.2kW 1.5kW, 1/3~ 23V, 3~ 23V)

More information

Design Specifications Operator Keypad Environmental and Operating Conditions

Design Specifications Operator Keypad Environmental and Operating Conditions Series 15J Mini Inverters Big inverter features do come in small packages! Take a look at Baldor s Series 15J Inverter control. Designed to save cabinet space without giving up the features available on

More information

CHAPTER KEYPAD OPERATION AND QUICKSTART. In This Chapter... The GS2 Digital Keypad GS2 Quickstart...3 6

CHAPTER KEYPAD OPERATION AND QUICKSTART. In This Chapter... The GS2 Digital Keypad GS2 Quickstart...3 6 CHAPTER KEYPAD OPERATION 3 AND QUICKSTART In This Chapter... The GS2 Digital Keypad.....................3 2 LED Display.........................................3 2 LED Indicators.......................................3

More information

NX Series Inverters. HVAC Pocket Programming Guide

NX Series Inverters. HVAC Pocket Programming Guide NX Series Inverters HVAC Pocket Programming Guide HVAC Pocket Programming Guide HVAC Pocket Programming Guide / Contents This guide provides a single reference document for the user of NXL HVAC (product

More information

SYSDRIVE 3G3HV Inverter Models The following 200- and 400-V class 3G3HV Inverter models are available.

SYSDRIVE 3G3HV Inverter Models The following 200- and 400-V class 3G3HV Inverter models are available. Function The 3G3HV High-capacity General-purpose Inverter is an easy-to-use inverter that has advanced features, such as PID control and energy-saving operations. SYSDRIVE 3G3HV Inverter Models The following

More information

G+ Mini Transition Guide. Product Transition Guide P3 Series 2 to G+ Mini

G+ Mini Transition Guide. Product Transition Guide P3 Series 2 to G+ Mini Transition Guide Product Transition Guide to Rev: Page Intentionally Left Blank Transition Guide September 2008 Page 2 of 24 Table of Contents 1.1 Overview...4 1.2 Drive Replacement Checklist...4 1.3 Ratings

More information

9. RS485 Communication

9. RS485 Communication 9. RS485 The communication between inverter and external controller is doing by RS485 using modular connector in cling to inverter controller. Function Initial Minimum Maximum code Value Unit Description

More information

Operating Instructions

Operating Instructions 4XH35QB151210 Small General Frequency Converter Operating Instructions 220V 0.75KW 5.5KW 400V 0.75KW 15KW Please read the instruction carefully and understand the contents so that it can be installed and

More information

AF-300 G11 Specifications. GE Industrial Systems. Product Specifications AF-300 G11

AF-300 G11 Specifications. GE Industrial Systems. Product Specifications AF-300 G11 apple GE Industrial Systems Product Specifications AF-300 G11 TM 1 Category Item Description Nominal Motor 230 VAC, 3 Phase 1/4 Hp to 125 Hp 460 VAC, 3 Phase 1/2 Hp to 450 Hp Braking Torque (Standard)

More information

Before you operate the inverter, the parameters that you must first program are the basic parameters.

Before you operate the inverter, the parameters that you must first program are the basic parameters. . Main parameters Before you operate the inverter, the parameters that you must first program are the basic parameters..1 Searching for changes using the history function () : History function History

More information

VFS9 Parameter List for Version110 or later

VFS9 Parameter List for Version110 or later VFS9 Parameter List for Version110 or later Setting Date Customer End user Application Application /Serial Inverter s Type-Form Quantity Inverter s Serial Motor s capacity If user s value is same as shipping

More information

Version number A=standard P=Cold Plate (Frame A only) T=Brake chopper (Frame A only) Input voltage 11=115VAC 21=230VAC 1φ 23=230VAC 3φ 43=400VAC

Version number A=standard P=Cold Plate (Frame A only) T=Brake chopper (Frame A only) Input voltage 11=115VAC 21=230VAC 1φ 23=230VAC 3φ 43=400VAC Type number key VFD 007 E 43 A Version number A=standard P=Cold Plate (Frame A only) T= (Frame A only) Input voltage 11=115VAC 21=230VAC 1φ 23=230VAC 3φ 43=400VAC VFD-E series Power 007=0.75kW 022=2.2kW

More information

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters.

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters. ~ ~ SX High performance Vector Control IP54 full range. Compact design & Robustness Built-in Filter according to C3 Class Built-in Fusses (From 200 kw) Safety according EN13849-1 and EN62061 standards

More information

INSTALLATION AND OPERATION MANUAL IODA INPUT/OUTPUT MULTI-FUNCTION BOARD (Part No. 9668)

INSTALLATION AND OPERATION MANUAL IODA INPUT/OUTPUT MULTI-FUNCTION BOARD (Part No. 9668) INSTALLATION AND OPERATION MANUAL IODA INPUT/OUTPUT MULTI-FUNCTION BOARD (Part No. 9668) Use with Models KBDA-24D, 27D, 29, 45, 48 See Safety Warning, on page 4. RoHS The information contained in this

More information

ACH550 HVAC Drive Submittal

ACH550 HVAC Drive Submittal ACH550 HVAC Drive Submittal DATE: PROJECT NAME: CONTRACTOR: ENGINEER: SUBMITTED BY: SUBMITTALS FOR: RECORD APPROVAL (Return a copy of the approved submittal) ACH550 Features Standard Features UL and cul

More information