Installations. Application. remote meter reading, we recommend 0-1mAfor the slave indicator.

Size: px
Start display at page:

Download "Installations. Application. remote meter reading, we recommend 0-1mAfor the slave indicator."

Transcription

1 KPMx Direct connection up to 500V line voltage, up to 25kV with HV adapter Monitoring during both live and standby conditions For use in land, marine, offshore, sub-sea and ocean floor Installations Comply with AODC 05 Code of Practice Megger - safe to.kvdc when aux power is OFF Immune to earth capacitance and voltage surges Analogue output proportional to meter reading (F-version) Specifications General Auxiliary : Optional Voltage: Contact rating: Analogue Output: F-versions Temperature: Weight: Front protection: 0-20, , 80-5 or 0-0VAC, 0-70Hz (Fuse 0.5A) 2-2VDC (Fuse 2A) AC: 0VA - 250V/2A max. DC: 50W - 0V/A max. Up to 20mA, max 500R Up to V, min 0kohm (other on request) -20 to +70ºC 0.2kgs IP5 (IP5 optional) Application The digitally controlled KPMx series monitors insulation level between a non-grounded (IT) AC mains and its protective earth, regardless of whether the mains is live or non-live (standby). The unit is for land, marine, offshore, sub-sea and ocean floor use. An AC or DC auxiliary voltage is required for the unit, if powered from a separate source the network can also be monitored during standby conditions. Only OE KPMx can be connected to each IT-system. The ohmmeter and the triple-zone status LEDs give at a glance the clear safety message: - ALARM (red zone) - WARIG (yellow zone) - HEALTHY (g reen zone) ITELLIGET SETTIGASSISTACE KPMx has a built-in Assistance tool for setting/verification of the trip levels and the analogue output. When either the Warning or Alarm potmeter on the rear is operated by user, the meter goes into Assistance Mode and meter reading and analogue output will reflect the potmeter setting. How to set alarmlevels: Firstly adjust potmeter fully clockwise (see that meter goes to the top), then adjust potmeter down to required Warning or Alarm setpoint. Without any movement of potmeters, the meter will revert to normal Insulation Monitoring Mode after approximately seconds. How to test analogue output signal: Adjust any trip level potmeter to activate Assistance Mode. Example: On a -20mA output, adjust potmeter fully anti clockwise for maand fully clockwise for 20mA. The KPMx range is designed to comply with specification AODC05 Code of Practice for the Safe Use of Electricity Under Water issued by IMCA. The unit meetsiec and the relevantenvironmental and EMC tests specified in IEC008/0092 and IEC00/05 respectively, to complywiththe requirementsofthemajorclassification Societies. General IDV MEASURIG PRICIPLE Insulation is measured between the complete galvanically interconnected AC network and its protective earth. The unit injects a DC voltage signal into the monitored system. The signal flows to ground via the path of the insulation fault, the level of flow indicates the insulation resistance. The measuring accuracy is not influenced by any normal kind of load attached to theac network. Trip levels and delays are settable on unit rear. A trip LED flashes when the trip level is passed, the relay trips when the delay has elapsed. The timer resets if the fault is removed during countdown. MEGGER SAFE When auxiliary power is OFF the unit input is automatically protected against megger test voltages up to.kvdc, and incorrect measurements caused by the unit s input impedance are avoided. OUTPUTS All F versions have an isolated analogue output proportional to meter reading. If output is used for remote meter reading, we recommend 0-mAfor the slave indicator. SAFETY When a voltage adapter (CHx, Ax or ARx) is used the signal to terminals and on KPMx and KPM5x is limited to a safe level, avoiding any dangerous voltage exposure to personnel. OTE Special versions of the KPM and KPM are available as: KPMM & KPMM - Insulation guard with DC detection function, protected against high-energy DC voltage imposed on the monitoredac supply. KPM2x & KPM2x - Insulation guard with measuring loop continuity monitoring. Page: of REF: Datasheet.KPMx - REV:.20/ All rights reserved to Megacon Megacon reserves the right to make any changes to the information at any time

2 KPMx KPME2 & KPMF - KPMG & KPMGF This unit is used for hospital, industrial, marine and offshore installations. Start of monitoring function is delayed when auxiliary power is switched on (default 5 secs delay). The unit has minimum 50 ms detection time for any insulation fault. Direct connection up to 500V line voltage. KPME2-SKK - KPMF-SKK & KPMG-SKK & KPMGF-SKK These optional units are similar to KPME2 & KPMF - KPMG & KPMGF. The only difference is, start of monitoring function is delayed when auxiliary power is switched on ( secs delay). Scale range: (> MΩ) KPME2 - - KPMF - X KPMG* X - KPMGF* X X WARIG: 0- ALARM: 0-0,-secs 2 Open M (> M) M 00k 0k 50k 0k 20k k 0k Output table (example for -20mA) 5.22mA 2 2.2mA.mA 5 8.8mA.9mA 0.98mA.28mA Open (>MΩ).00mA KPME & KPMF - KPMG & KPMGF This unit is used for marine, ROV and offshore installations. Start of monitoring function is delayed when auxiliary power is switched on (default secs delay). The unit has minimum 50 ms detection time for any insulation fault. (Recommended for thruster standby monitoring) Direct connection up to 500V line voltage. Up to,kv via HV adaptor CHx ora, series. Scale range: 0-MΩ - (> 0MΩ) KPME - - KPMF - X KPMG* X - KPMGF* X X WARIG: 0-MΩ ALARM: 0-MΩ 0,-secs 2 Open 0M (> 0M) M M M 500k 00k 200k 0k 0k Output table (example for -20mA) mA 0.59mA mA.9mA MΩ.98mA MΩ.28mA Open (0MΩ).00mA Page: 2 of

3 KPMx KPME2 - KPMF2 - KPMG2 & KPMGF2 This unit is used for marine, ROV and offshore installations. Start of monitoring function is delayed when auxiliary power is switched on (default secs delay). The unit has minimum 50 ms detection time for any insulation fault. (Recommended for thruster standby monitoring) Direct connection up to 500V line voltage. Up to,kv via HV adaptor CHx ora, series. Scale range: 0-MΩ - (> 0MΩ) KPME2 - - KPMF2 - X KPM G2* X - KPM GF2* X X WARIG: 0-MΩ ALARM: 0-MΩ 0,-secs Output table (example for -20mA) 2 5, 0 0 m A 2 0, 0 0 m A 5, 0 0 m A 0, 0 0 m A 5, 0 0 m A 0, 0 0 m A O p e n 0 M 7 M 5 M M 2 M M 0. 5 M 0 k Value (scale) 0.5MΩ 2MΩ MΩ 5MΩ 7MΩ MΩ Open (0MΩ) ma output 2.0mA.59mA 8.7mA.9mA.98mA.28mA.00mA Mohm KPMH & KPMHF - KPMHG & KPMHGF This unit is specifically designed for sub-sea monitoring and includes the advanced Load Distortion and Earth-capacitance Detector (LDED). to the latent high RC product at the high end part of the measuring range. The LDED will then momentarily Scale range: 0- M Ω - (> 0 MΩ) KPMH - - KPMHF - X KPMHG* X - KPMHGF* X X WARIG: 0-MΩ ALARM: 0-MΩ 0,-secs LDED function has minimum secs detection time for any insulation fault. Direct connection up to 500V line voltage. Up to,kv via HV adaptor CHx ora, series. 2 Open 0M (> 0M) M M M 500k 00k 200k 0k 0k Output table (example for -20mA) mA 0.59mA mA.9mA MΩ.98mA MΩ.28mA Open (0MΩ).00mA Page: of

4 KPMx KPM5H & KPM5HF - KPM5HG & KPM5HGF Start of monitoring has a 0 secs delay. This unit is for marine, offshore, sub-sea and ocean floor use. It has a wide measuring range in order to detect degradation of insulation at its origin. An important feature is the unit s unique inhibit function, controlled by the Load Distortion and Earth-capacitance Detector (LDED). to the latent high RC product at the high end part of the measuring range. The LDED will then momentarily Scale range: - 500MΩ - (> 2GΩ) KPM5H - - KPM5HF - X KPM5HG* X - KPM5HGF* X X WARIG: -0 ALARM: -0 LDED function has minimum 5 secs detection time for any insulation fault. Connection up to 25kV via HV adaptor ARx orax series. 2 Open (> 2G) 500M 5G 00M G 500M 200M 00M 0M 50M 0M 70M M 0M M 500k k Output table (example for -20mA).8mA MΩ 2.28mA 0MΩ.57mA 0MΩ 8.mA 200MΩ.mA 00MΩ.9mA 500MΩ,20mA Open (>2GΩ).00mA Mohm k KPM5G & KPM5GF - KPM5L & KPM5LF Start of monitoring has a 0 secs delay. This unit is for marine, offshore, sub-sea and ocean floor use. It has a wide measuring range in order to detect degradation of insulation at its origin. An important feature is the unit s unique inhibit function, controlled by the Load Distortion and Earth-capacitance Detector (LDED). to the latent high RC product at the high end part of the measuring range. The LDED will then momentarily Scale range: 50-5GΩ - (> GΩ) KPM5G* X - KPM5GF* X X KPM5L - - KPM5LF - X WARIG: 50-GΩ ALARM: 50-GΩ LDED function has minimum 5 secs detection time for any insulation fault. Connection up to 25kV via HV adaptor ARx orax series. 2 Open (> G) 5G G 500M 00M 50M 70M 0M 500k Output table (example for -20mA) 50 0MΩ 70MΩ 2.28mA 50MΩ.57mA 00MΩ 8.mA 500MΩ.mA GΩ.9mA 5GΩ.20mA Open (>GΩ).00mA Page: of

5 KPMx KPM5E & KPM5F - KPM5 & KPM5F Start of monitoring has a 0 secs delay. This unit is for marine, offshore, sub-sea and ocean floor use. It has a wide measuring range in order to detect degradation of insulation at its origin. An important feature is the unit s unique inhibit function, controlled by the Load Distortion and Earth-capacitance Detector (LDED). to the latent high RC product at the high end part of the measuring range. The LDED will then momentarily Scale range: 5MΩ- GΩ - (>2GΩ) KPM5E* X - KPM5F* X X KPM5 - - KPM5F - X WARIG: 5MΩ-5GΩ ALARM: 5MΩ-5GΩ LDED function has minimum 5 secs detection time for any insulation fault. Connection up to 25kV via HV adaptor ARx orax series. 2 Open (> 2G) G G G 500M 00M 200M 0M 5M Output table (example for -20mA) 5MΩ 0MΩ 200MΩ 2.28mA 00MΩ.57mA 500MΩ 8.mA GΩ.mA GΩ.9mA GΩ.20mA Open (>2GΩ).00mA High Voltage Adaptors up to 25kVAC for KPM x & KPM5x series CH/, up to.kvac (for KPMx series) CH/, up to.kvac (for KPMx series) CH/5 up to 5kVAC (for KPMx series) A, up to,kvac (for KPMx series) A7 up to 7kVAC (for KPM5x series) A up to kvac (for KPM5x series) A25 up to 25kVAC (for KPM5x series) AR7 up to 7kVAC (for KPM5x series) AR up to kvac (for KPM5x series) Page: 5 of

6 Comport ISULATIO GUARD FOR O-GROUDED AC ETWORKS KPMx + - Relays shown de-energised, a fail-safe relay energises when unit is powered R R2 R Analogue O/P (Optional) KPMx Reset (only latching versions) AC Aux (Standard) Line/ eutral PE DC Aux (Optional) ~ ~ Analogue Output OTE: See below for correct connection + - KPMF, KPMGF, KPMF-SKK, KPMGF-SKK, KPMF, KPMGF, KPMF2, KPMGF2, KPMHF, KPMHGF, KPM5HF, KPM5HGF, KPM5GF, KPM5LF, KPM5F and KPM5F have an analogue output proportional to meter reading. (Special outputs are available on request) Add suffix from table below to type designation to specify output required: O/P O/P2 O/P 0 - ma 0-20mA - 20mA O/P O/P7 O/P8 /A /A 0 - VDC O/P /A O/P9 /A O/P5 /A O/P /A Dimensions mm mm 5mm Mounting Bracket DI9 PAEL CUTOUT 92 x 92mm.25 to 8mm thick EUTRAL VOLTAGE IPUT LIE VOLTAGE IPUT (< 500V) KPMx R (L) S (L2) T (L) ~/- * (< 500V) To be connected * to any line voltage KPMx ~/+ ~/- R (L) S (L2) T (L) Aux. CH/, (<,kv) CH/, (<,kv) KPMx * CH/, (<,kv) CH/, (<,kv) KPMx 2 ~/- 2 ~/- CH/5 (< 5kV) A, (<,kv) KPMx * CH/5 (< 5kV) KPMx ~/- ~/+ ~/- Aux. Ax (< 25kV) KPM5x PE OUTPUT PE OUTPUT ~/- ARx (< kv) KPM5x ~/+ ~/- Aux. ORDERIG EXAMPLE: Type: KPM5GF Aux. : VAC etwork Voltage: kvac Analogue O/P: (O/P) -20mA : 500K - 5Gohm Page: of

DEIF A/S. Insulation monitor. Type SIM-Q

DEIF A/S. Insulation monitor. Type SIM-Q Insulation monitor 4921232C Monitoring of insulation resistance on ungrounded AC networks (IT network) Working voltage up to 69V AC, withstands up to V DC Measuring range 1...Mohm or 1...Mohm Alarm on

More information

DEIF A/S. Insulation monitor. Type SIM-Q/SIM-Q LF

DEIF A/S. Insulation monitor. Type SIM-Q/SIM-Q LF / LF Insulation monitor Monitoring of insulation resistance on ungrounded AC networks (IT network) Working voltage up to 69V AC, withstands up to V DC Measuring range...kω or 1...MΩ Working frequency down

More information

TCM-2 Thyristor Control Module DATA SHEET

TCM-2 Thyristor Control Module DATA SHEET TCM-2 Thyristor Control Module TCM-2 Thyristor DATA DATA SHEET Control Module DATA SHEET Insulation monitors, Warning delay and power-up delay Indication of set point on front Measuring range up to 440

More information

Digital Multifunction Instrument - Rish Master 3440

Digital Multifunction Instrument - Rish Master 3440 Application Rish Master 3440 measures important electrical parameters in 3 phase and single phase etwork & replaces the multiple analog panel meters. It measures electrical parameters like AC current,

More information

Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Contact expander module for increasing the number of available contacts Approvals Unit features Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous

More information

Installation/operation instructions. Insulation monitor type SIM-Q/SIM-Q LF D (UK) Measuring range 1...0Mohm or 10...

Installation/operation instructions. Insulation monitor type SIM-Q/SIM-Q LF D (UK) Measuring range 1...0Mohm or 10... Installation/operation instructions Insulation monitor type SIM-Q/SIM-Q LF Monitoring of insulation resistance on an AC network Working voltage up to 690V AC, withstands up to 1000V DC Measuring range

More information

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS INSTRUCTIONS MANUAL IM831-U v0.92 HRI-R40W sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS INDEX: GENERAL TYPES ACESSORIES AND OPTIONS

More information

MIT415 Insulation tester

MIT415 Insulation tester MIT415 Insulation tester General features o 10V & 100V ESD testing o 25V, 50V, 250V & 500V additional ranges o Insulation testing up to 50Gohms (500V) o Continuity testing at 200mA or 20mA from 0.01ohms

More information

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication: Application : RISH Master 3490 SS is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy having auto-resetting 8 digit seven segment LED counter. The unit

More information

7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Answers for energy

7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Answers for energy Reyrolle Protection Devices 7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Answers for energy 7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Description Additional Options Solkor

More information

Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay

Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay Technical Datasheet RELAY-1 RELAY-2 k V Hz RESET ABH TEST True RMS Measurement True RMS Digital Protection V/Hz is used to protect against Over Voltage, Under Voltage, Phase Unbalance, Phase Sequence detection,

More information

Reyrolle Protection Devices. 7PG21 Solkor R/Rf Pilot Wire Current Differential Protection. Answers for energy

Reyrolle Protection Devices. 7PG21 Solkor R/Rf Pilot Wire Current Differential Protection. Answers for energy Reyrolle Protection Devices 7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Answers for energy 7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Additional Options 15kV Isolation

More information

INSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W

INSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W Page 2 / 16 INDEX: GENERAL TYPES ACESSORIES AND OPTIONS INSTALLATION WIRING DIAGRAMS CONNECTING TERMINALS DIAGRAMS WIRING DIAGRAM DESCRIPTION WORKING DESCRIPTION AND KEYBOARD WORKING DESCRIPTION AND PROGRAMMING

More information

INDEX. Micro-ohmmeter MH-10 Page 3. MI (5, 10, 15, 20 kv) Page 4 Mega-ohmmeter MD (5 kv) Page 4

INDEX. Micro-ohmmeter MH-10 Page 3. MI (5, 10, 15, 20 kv) Page 4 Mega-ohmmeter MD (5 kv) Page 4 Micro-ohmmeter MH-10 Page 3 MI (5, 10, 15, 20 kv) Page 4 Mega-ohmmeter MD (5 kv) Page 4 Earth resistance meter TL-5 Page 5 Indirect earth contact simulator MPC (5, 20, 50 A) Page 6 Trip time tester CR

More information

Technical Datasheet. True RMS Digital Protection Relay. Voltage Protection Relay

Technical Datasheet. True RMS Digital Protection Relay. Voltage Protection Relay Technical Datasheet RELAY-1 RISHABH k V RESET True RMS Digital Protection Relay RELAY-2 TEST True RMS Measurement RISH Relay V is used to protect against Over Voltage, Under Voltage, Phase Sequence detection,

More information

Monitoring Relays 3-Phase Load Guard Types DWB01, PWB01

Monitoring Relays 3-Phase Load Guard Types DWB01, PWB01 Monitoring Relays 3-Phase Load Guard Types DWB0, PWB0 DWB0 PWB0 TRMS load guard relays for three phase balanced applications Measuring if the power factor is within set limits Measure voltage on own power

More information

Relay. Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay

Relay. Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay Line Monitoring Technical Datasheet RISH RELAY-1 RELAY-2 RISHABH k V Hz True RMS Digital Protection RISH V/Hz is used to protect against Over Voltage, Under Voltage, Phase Unbalance, Phase Sequence detection,

More information

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection Quick Start Guide TECO F510 Inverter This guide is to assist you in installing and running the inverter and verify that it is functioning correctly for it s main and basic features. For detailed information

More information

7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Energy Management

7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Energy Management Reyrolle Protection Devices 7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Energy Management 7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Description Solkor R & Solkor Rf

More information

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01 Monitoring Relays True RMS 3-Phase, 3-Phase+, Multifunction Types DPC01 Product Description 3-phase or 3-phase+neutral line voltage monitoring relay for phase sequence, phase loss, asymmetry, over and

More information

Contents. Measurement and checking equipment for transformation centers Micro-ohmmeter MH-10 Page 3. Indirect earth contact simulator TL-5 Page 5

Contents. Measurement and checking equipment for transformation centers Micro-ohmmeter MH-10 Page 3. Indirect earth contact simulator TL-5 Page 5 Measuring and testing equipments P 6 P.6.01 GB for substations Micro-ohmmeter MH-10 Page 3 Mega-ohmmeter MI (5, 10, 15, 20 kv) Page 4 MD (5 kv) Page 4 Indirect earth contact simulator TL-5 Page 5 Indirect

More information

Technical Data Sheet. x1000. kwh R Y B

Technical Data Sheet. x1000. kwh R Y B Technical Data Sheet x1000 Von kwh IRev 3600 imp /kwh R Y B is a compact multifunction instrument which is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy

More information

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01 Monitoring Relays rue RMS 3-Phase, 3-Phase+, Multifunction ypes DPC01, PPC01 DPC01 Product Description 3-phase or 3-phase+neutral line voltage monitoring relay for phase sequence, phase loss, asymmetry,

More information

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C) XR1 Rotor Earth Fault Relay Manual XR1 (Revision C) Woodward Manual XR1 (EN) Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided by

More information

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime Issued: 5.06.999 Status: 5.06.999 Version: B/09..00 Data subject to change without notice Features Overvoltage and undervoltage protection Single- or three-phase operation High-set overvoltage stage with

More information

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New) XR1 Rotor Earth Fault Relay (May 2007) Manual XR1 (Revision New) Woodward Manual XR1 GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided

More information

MIT400/2 CAT IV Insulation testers

MIT400/2 CAT IV Insulation testers MIT400/2 CAT IV Insulation testers MIT400/2 CAT IV Insulation testers Designed for Electrical and Industrial testing Insulation testing up to 1000 V and 200 GΩ range Stabilised insulation test voltage

More information

Type Nominal voltage (V) Code HSV V

Type Nominal voltage (V) Code HSV V Speed control Speed control relay - mm Control of overspeed, underspeed, operating rate, stopping Measurement via discrete sensors - -wire PNP or NPN, Namur, voltage 0-0V or volt-free contact type Works

More information

Analog Digital Multimeter with Insulation Resistance Measurement

Analog Digital Multimeter with Insulation Resistance Measurement RISH MIT 30 Product Features: RISH MIT 30 is Analog Digital Multimeter with insulation resistance measurement, which measures VAC, VDC, VAC+DC,Frequency, ma DC, ma AC+DC,Resistance, continuity, Diode,

More information

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300 Monitoring Technique VARIMETER IMD Insulation monitor RN 5897/300 0274214 Your Advantages For mobile generator sets according to DIN VDE 0100-551 Preventive fire and system protection Detection of symmetric

More information

isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems

isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems T M 1 isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems Technical Bulletin NAE1012110 / 12.2011 isolr275 / AGH-LR Ground Fault Monitor

More information

AMIK Three Phase Digital Panel Meters

AMIK Three Phase Digital Panel Meters AMIK Three Phase Digital Panel Meters USA SICE 1936 ELIAILIT EOD MEASUE Special Features 3 Line 4 Digits ultra bright LED Display (up to 9999) On site Programmable CT/PT atios User selectable CT Secondary

More information

KEY FEATURES. Selectable modes of control : Phase Angle or Burst Fire (Single- Cycle/Dual-Cycle & adjustable STD Burst Firing)

KEY FEATURES. Selectable modes of control : Phase Angle or Burst Fire (Single- Cycle/Dual-Cycle & adjustable STD Burst Firing) X20092 DMFC36 Issue: 2 User manual Date: 31/10/14 Page: 1 of 10 KEY FEATURES Standard DIN Rail Mounting Selectable modes of control : Phase Angle or Burst Fire (Single- Cycle/Dual-Cycle & adjustable STD

More information

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES) Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA

More information

05/09/2012

05/09/2012 17.5 mm EMER8 Part number 88829198 Multifunction or mono-function Multi-range (7 ranges) Multi-voltage or single voltage Screw terminals LED status indicator (1 voltage present LED, 1 timer ON LED) Option

More information

400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output)

400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output) MODEL EM4000ACF Multifunction Transducer for alternating voltage and current Power supply voltages: Suitable for DIN-rail mounting 85 240Vac 400,440Vac 24 65Vdc 100..330Vdc V, A, W, VA, var, Hz, V, Avg.

More information

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

DSA150 Series. xxx Series. 150 Watts.   AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125. 15 Watts xxx Series Ultra Slim Design 15% Peak Load for 3 seconds Ambient Operation from -1 C to +7 C High Efficiency Selectable Overload Characteristic Selectable Remote Inhibit or Enable 3 Year Warranty

More information

MIT400/2. CAT IV Insulation testers MIT430/2: CAT IV Insulation testers

MIT400/2. CAT IV Insulation testers MIT430/2: CAT IV Insulation testers MIT400/2 Designed for electrical and industrial testing Insulation testing up to 1000 V and 200 GΩ range Stabilized insulation test voltage (New) Single range, faster continuity testing from 0.01 Ω to

More information

Protection components

Protection components General Application LT3-Si thermistor protection units continuously monitor the temperature of the machines to be protected (motors, generators, etc.) by means of PTC thermistor probes embedded in the

More information

Current monitor Type C 551

Current monitor Type C 551 Current monitor Type C 551 Relay for current monitoring, single-phase Monitoring AC and DC for overcurrent or undercurrent 1 yellow LED for indication of the relay state 1 green LED for indication of the

More information

RISH MIT 30 Analog Digital Multimeter with Insulation Resistance Measurement

RISH MIT 30 Analog Digital Multimeter with Insulation Resistance Measurement RISH MIT 30 Analog Digital Multimeter with Insulation Resistance Measurement Data Sheet Analog Digital Multimeter with Insulation resistance www.rishabh.co.in Page 1 of 6 Version: J 28/12/2011 Application

More information

Rotek AS440 compatible VOLTAGE REGULATOR (AVR)

Rotek AS440 compatible VOLTAGE REGULATOR (AVR) Rotek AS440 compatible VOLTAGE REGULATOR (AVR) SPECIFICATION INSTALLATION AND ADJUSTMENTS General description Technical specification AS440 is a half wave phase controlled thyristor type AVR and forms

More information

1 Model 3153 Automatic Insulation Voltage Withstand Testing Voltage Control from a PC Full Remote Control All test parameters can be controlled by RS-232C or GP-IB, including test voltage, cut-off current,

More information

SPECIFICATION, CONTROLS AND ACCESSORIES

SPECIFICATION, CONTROLS AND ACCESSORIES AS440 Automatic Voltage Regulator (AVR) SPECIFICATION, CONTROLS AND ACCESSORIES English Original Instructions A043Y697 (Issue 2) Table of Contents 1. DESCRIPTION... 1 2. SPECIFICATION... 3 3. CONTROLS...

More information

Enclosed Power Supplies

Enclosed Power Supplies , 000 Watt Features Compact metal case with screw terminal block Dual and triple output models with isolated outputs Universal input VAC EMI/EMC compliance with E 000-- and E 000-- Compliance to E 000--

More information

Product Catalog PRODUCT CATALOG. Power supply system & test equipment

Product Catalog PRODUCT CATALOG. Power supply system & test equipment Product Catalog PRODUCT CATALOG 2018 2018 Power supply system & test equipment. 138/79, Moo 2 Tambon Ban Klang, Amphoe Mueang Pathumthani, Pathumthani Province 12000, Thailand. Tel: +66 21475048-9 Fax:

More information

SPECIFICATION. Online UPS 3000VA

SPECIFICATION. Online UPS 3000VA Page 1 / 7 DESCRIPTION Pure sine-wave output UPS on-line double conversion type. INPUT AC Mains voltage 230V ac 1 phase Mains voltage range 184...264V ac Mains frequency range 47...63Hz Power factor at

More information

AS440 AUTOMATIC VOLTAGE REGULATOR (AVR)

AS440 AUTOMATIC VOLTAGE REGULATOR (AVR) AS440 AUTOMATIC VOLTAGE REGULATOR (AVR) SPECIFICATION INSTALLATION AND ADJUSTMENTS General description Technical specification AS440 is a half wave phase controlled thyristor type AVR and forms part of

More information

Precautions in Using the product:

Precautions in Using the product: DP Series ISTRUCTIO MAUA 6. Avoid penetration of metal chips when processing mounting holes. 7. Avoid places where the products is subjected to penetration of liquid, foreign substance, or corrosive gas.

More information

Amplifiers and battery charger

Amplifiers and battery charger DPAfour Digital Power Amplifiers Public Address - Voice Alarm Audio Distribution over IP Commercial Audio Intelligent Acoustic Solutions Intercommunication Loudspeakers Amplifiers and battery charger DPAfour

More information

NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function.

NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function. REGULATION AUTOMATIC SYNCHRONIZER for GENERATOR NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function. NPRG870 adds

More information

CompoBus/D-type Digital Controller

CompoBus/D-type Digital Controller CompoBus/D-type Digital Controller Digital Controller for the CompoBus/D and Conforming the DeviceNet Conforms the DeviceNet and connects a Programmable Controller without any programming. High performance

More information

DLP/E Series Instruction Manual

DLP/E Series Instruction Manual Instruction Manual BEFORE USIG TE POWER SUPPY UIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.

More information

DATA SHEET Reverse power relays, RMP-121D ANSI code 32

DATA SHEET Reverse power relays, RMP-121D ANSI code 32 DATA SHEET Reverse power relays, RMP-121D ANSI code 32 Protection against "motoring" Single phase measurement LED indication of fault condition Timer-controlled tripping LED indication for activated relay

More information

NPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator

NPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator REGULATION Automatic Synchronizer for Generator NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function. NPRG870 adds

More information

Monitoring Relays 3-Phase Active power Types DWB02, PWB02

Monitoring Relays 3-Phase Active power Types DWB02, PWB02 Monitoring Relays 3-hase Active power Types DWB02, WB02 DWB02 roduct Description DWB02 and WB02 are precise TRMS active power monitoring relays for 3- phase balanced systems. They can be used for monitoring

More information

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49 TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument True RMS measurement User-friendly programing Four different types for optimal specification RS485 interface For 3- or 4-wire connection Compact

More information

Dielectric strength tester RMG15AC

Dielectric strength tester RMG15AC Dielectric strength tester RMG15AC The MG series electrical safety testers perform easily and simply all the electrical tests according to the VDE, UL, CSA standards and to the main EN European standards

More information

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004 Current Monitoring Relay Data Sheet 08/2004 Functions Structure Current monitoring of direct and alternating current in 1-phase networks with settable threshold values, starting override and response delay

More information

Installation- / Monitoring technique

Installation- / Monitoring technique Installation- / Monitoring technique ifferential current monitor IP 5883, Type B for AC and C systems varimeter 0249633 IP 5883 N 5018/035 N 5018/030 According to IEC/EN 62 020, VE 0663 To detect earth

More information

Operations Manual. Model NT11 & NT11-E. June 18 th 2002

Operations Manual. Model NT11 & NT11-E. June 18 th 2002 Operations Manual Model NT11 & NT11-E June 18 th 2002 3609 North 44 th Street Phoenix, AZ 85018-6023 Internet: www.northstarcontrols.com Fax: (941) 426-0807 Tel: (941) 426-6396 Manual Contents Glossary

More information

General Specifications

General Specifications General Specifications MODEL UT50L Limit Controller GS 5DD-0E Overview The UT50L is an FM approved limit controller that can be configured either as a high limit or as a low limit controller by a user.

More information

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS INSTRUCTION MANUAL BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS 1/23 More information than that reported

More information

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES 2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES Medium-voltage rack-mount power supplies Page 2 The MV2000 series high-performance, medium output

More information

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000

More information

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters measures important electrical parameters in phase and single phase etwork & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, Power, Energy

More information

Radio Touch Order no.: 2880 xx. Operation and installation instructions. 1 Safety instructions. 2 Structure of the device (Figure 1) Radio Touch

Radio Touch Order no.: 2880 xx. Operation and installation instructions. 1 Safety instructions. 2 Structure of the device (Figure 1) Radio Touch Radio Touch Order no.: 2880 xx Operation and installation instructions 1 Safety instructions Electrical equipment must only be installed and assembled by a qualified electrician in accordance with the

More information

ISOMETER IRDH575. Approvals

ISOMETER IRDH575. Approvals Insulation monitoring device for unearthed AC, DC and AC/DC systems (IT systems) with control and display function for EDS insulation fault location systems IRDH575_D00089_02_D_XXEN/09.2018 Insulation

More information

27/04/2015

27/04/2015 Modular Carril DIN 35 mm HIL Part number 84871120 Control of AC and DC currents Automatic recognition of AC/DC Measurement ranges from 2 ma to 10 A Choice between over and undercurrent True RMS measurement

More information

HA400 HA900 HA401 HA901

HA400 HA900 HA401 HA901 A/ R/L R/S High-Speed Digital Controller - or loops HA Series HA00 HA900 HA0 HA90 General Description he HA series are digital PID controllers with a high speed sampling time of ms (0.0 sec) with high-resolution

More information

Analogue temperature controllers

Analogue temperature controllers Analogue temperature controllers CT8A Input by J-K thermo-couple or by thermo-resistance Pt 00 (-wire) regulation modes : ON/OFF or proportional derivative selected by wiring Relay output Specifications

More information

MIT400/2 CAT IV Insulation testers

MIT400/2 CAT IV Insulation testers MIT400/2 CAT IV Insulation testers MIT400/2 CAT IV Insulation testers Designed for Electrical and Industrial testing Insulation testing up to 1000 V and 200 GΩ range Stabilised insulation test voltage

More information

RMV-122D, RMV-132D ANSI

RMV-122D, RMV-132D ANSI DATA SHEET Voltage relays, RMV-112D, RMV-122D, RMV-132D ANSI codes 27/59, 59, 27 Under-voltage/over-voltage 3-phase measurement LED indication of fault condition Timer-controlled tripping LED indication

More information

presentation contents application advantages

presentation contents application advantages presentation contents page presentation protection functional and connection schemes other connection schemes connection characteristics 9 installation 0 commissioning ordering information Sepam 00 is

More information

GPM. Field and Stator Ground Fault Protection Modules. Instruction Manual AF1. GE Grid Solutions

GPM. Field and Stator Ground Fault Protection Modules. Instruction Manual AF1. GE Grid Solutions GE Grid Solutions GPM Field and Stator Ground Fault Protection Modules Instruction Manual Product version: 2.0x GE publication code: 1601-0256-AF1 (GEK-113231D) 1601-0256-AF1 Copyright 2017 GE Multilin

More information

CableTroll 2410 PN: /03. User Manual

CableTroll 2410 PN: /03. User Manual CableTroll 2410 PN: 01-2410- 02/03 User Manual UG CT 2410-RMU February 2010 This document describes the installation and configuration of the RMU Fault Indicator Product no: 01-2410- 02/03 Rev. 0.1 (21.01.09)

More information

THE SIGNAL CONDITIONING SPECIALISTS

THE SIGNAL CONDITIONING SPECIALISTS COLTERLEC ELEC TRIC AL ENGINEERING PRODUC TS THE SIGNAL CONDITIONING SPECIALISTS COLTERLEC ELEC TRIC AL ENGINEERING PRODUC T S The Signal Conditioning Specialists SECTION 91 TM THE SIGNAL CONDITIONING

More information

Relion 605 series Self-Powered Feeder Protection REJ603 Product Guide

Relion 605 series Self-Powered Feeder Protection REJ603 Product Guide Relion 605 series Relion 605 series Self-Powered Feeder Protection Product Guide Contents 1 Description...3 2 Protection functions...3 3 Application...4 4 Self-supervision...4 5 Inputs and outputs...4

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C),

More information

1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01 Monitoring Relays -Phase True RMS AC/DC Over and Under Current Types DIC0, PIC0 DIC0 PIC0 TRMS AC/DC over + under, over+over, under+under current and voltage monitoring relays DC process signal plus/minus

More information

RISH Delta Energy / Demand (Multifunction instrument) Data Sheet

RISH Delta Energy / Demand (Multifunction instrument) Data Sheet ISH Delta Energy / Demand (Multifunction instrument) Data Sheet www.rishabh.co.in Page 1 of 6 Version: D 14 / 03 / 2012 Application: ISH Delta Energy measures important electrical parameters in 3 phase

More information

Monitoring Relays 3-Phase Active power direction Types DWB03, PWB03

Monitoring Relays 3-Phase Active power direction Types DWB03, PWB03 Monitoring Relays 3-Phase Active power direction ypes DWB03, PWB03 DWB03 PWB03 RMS active power relays for three phase balanced applications Measuring if active power is within set limits Measure their

More information

Technical description MT24. User manual WARNING GENERAL INSTRUCTIONS GENERAL DESCRIPTION

Technical description MT24. User manual WARNING GENERAL INSTRUCTIONS GENERAL DESCRIPTION WARIG The equipment makes a compact set of the switchboard. Just this set is safe from the point of electrical shock. Therefore do not use other power supplies or circuits than mentioned in this direction

More information

MIT400 CAT IV Industrial Insulation Testers

MIT400 CAT IV Industrial Insulation Testers MIT400 CAT IV MIT400 CAT IV CAT IV 600 V applications TRMS & DC Voltage measurement Insulation testing up to 1000 V and 200 GΩ Continuity testing at 200 ma or 20 ma down to 0.01 Ω Pass/Fail limit alarms

More information

800W Single Output Power Supply

800W Single Output Power Supply Features : Universal AC input with active PFC Programmable output Voltage ( 0% ~ 05% ) Programmable output Current ( 0% ~ 05% ) U profile, High power density Constant current limiting High efficiency up

More information

TOS5300 SERIES Hipot Tester/Hipot Tester with Insulation Resistance Test

TOS5300 SERIES Hipot Tester/Hipot Tester with Insulation Resistance Test A new standard for Hipot & Insulation resistance testing Applied to World-Wide input voltage TOS5301 TOS5300 TOS5302 TOS5300(ACW) TOS5301(ACW/DCW) TOS5302(ACW/IR) New low-cost standard model that provides

More information

Content. Monitoring relay pluggable. 1-phase current monitoring relay phase direct-current voltage monitoring relay... 5.

Content. Monitoring relay pluggable. 1-phase current monitoring relay phase direct-current voltage monitoring relay... 5. Content Monitoring relay pluggable 1-phase current monitoring relay... 5.2 1-phase direct-current voltage monitoring relay... 5.6 1-phase voltage monitoring relay... 5.10 3-phase voltage monitoring relay...

More information

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER OPERATOR S MANUAL DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER Masibus Automation & Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar-382044, Gujarat, India Web Site: www..com

More information

Sine Wave Power Inverter GD150/GD300 Series User s Manual

Sine Wave Power Inverter GD150/GD300 Series User s Manual Sine Wave Power Inverter GD150/GD300 Series User s Manual Ver.1.04E Table of Contents 1. Safety Instructions... 3 2. General Information... 4 3. Inverter Features... 5 3-1 Specification...5 3-2 De-rating

More information

MIT400 CAT IV Industrial Insulation Testers

MIT400 CAT IV Industrial Insulation Testers MIT400 CAT IV MIT400 CAT IV CAT IV 600 V applications TRMS & DC Voltage measurement Insulation testing up to 1000 V and 200 GΩ Continuity testing at 200 ma or 20 ma down to 0.01 Ω Pass/Fail limit alarms

More information

Industrial PSU with universal input voltage range ( VAC line to line) and configurable output voltage. North America

Industrial PSU with universal input voltage range ( VAC line to line) and configurable output voltage. North America World-Wide 3-phase Input Voltage Range (nom. 200 Vrms to 480 Vrms), PF > 0.94 High Power Density 16 W/in 3 94% Typical Efficiency Parallel Operation up to 16 Units (50.4 kw) Cold-Plate Cooling System -25

More information

Ramp/Soak Temperature Controller REX-P250

Ramp/Soak Temperature Controller REX-P250 EX-P0 General The EX-P0 is a high performance ramp/soak controller with a storage capacity of segments in patterns. Each pattern consists of up to segments and patterns can be linked for maximum pattern

More information

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O Product data sheet Characteristics RE22R2MMU Multifunction Timer Relay - 24VDC/24..240 V AC - 2 C/O Main Range of product Product or component type Discrete output type Device short name Nominal output

More information

Energy Management. Type WM14-96 Basic Version. Product Description. How to order WM14-96 AV5 3 D PGX. Type Selection. Input specifications.

Energy Management. Type WM14-96 Basic Version. Product Description. How to order WM14-96 AV5 3 D PGX. Type Selection. Input specifications. Energy Management Power Analyzer Type WM-96 Basic Version Optional dual pulse output Alarms (visual only) V, An Optional galvanically insulated measuring inputs Product Description 3-phase power analyzer

More information

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+) Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics Power Quality Monitor Individual Harmonics measurement upto 56th Harmonics True representation of Voltage & Current waveforms. Phasor Representation of All 3 phases for system analysis Real Time Clock

More information

DATA SHEET Differential current relays, RMC-131D ANSI code 87

DATA SHEET Differential current relays, RMC-131D ANSI code 87 DATA SHEET Differential current relays, RMC-131D ANSI code 87 Measurement of 3-phase currents Non-stabilised measurement Timer-controlled tripping Extra change-over relay contact for signalling DEIF A/S

More information

1 340XRi / 680XRi / 1220XRi Applications. 340XRi, 680XRi, 1220XRi Application manual.

1 340XRi / 680XRi / 1220XRi Applications. 340XRi, 680XRi, 1220XRi Application manual. 1 340XRi / 680XRi / 20XRi Applications 340XRi, 680XRi, 20XRi Application manual. www.sprint-electric.com - Data Product manuals Technical help Drive glossary FAQ Brochures Images Data Product manuals 340XRi

More information

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM SYSTEM OVERVIEW Pollution monitoring of high voltage insulators in electrical power transmission and distribution systems, switchyards and substations is essential in order to minimise the risk of power

More information

PSV3St _ Phase-Sequence Voltage Protection Stage1 (PSV3St1) Stage2 (PSV3St2)

PSV3St _ Phase-Sequence Voltage Protection Stage1 (PSV3St1) Stage2 (PSV3St2) 1MRS752324-MUM Issued: 3/2000 Version: D/23.06.2005 Data subject to change without notice PSV3St _ Phase-Sequence Voltage Protection Stage1 (PSV3St1) Stage2 (PSV3St2) Contents 1. Introduction... 2 1.1

More information