Quick Guide - Some hints to improve ABR / ABRIS / ASSR recordings

Size: px
Start display at page:

Download "Quick Guide - Some hints to improve ABR / ABRIS / ASSR recordings"

Transcription

1 Quick Guide - Some hints to improve ABR / ABRIS / ASSR recordings Several things can influence the results obtained during ABR / ABRIS / ASSR testing. In this guide, some hints for improved recordings will be described. All the suggestions listed below can be applied to the ABR, ABRIS and ASSR module. Skin Preparation and Electrodes 1. Preparing the skin Always use an abrasive preparation gel (e.g., NuPrep) to ensure that the top layer of skin (epidermis) is cleaned and oil is removed. The skin may become a little red after an appropriate preparation, and you should aim to get impedances below 3kOhm. Note Be careful not to damage the skin. Neonates Some clinicians use only alcohol wipes/pads to remove vernix prior to ABR recording on neonates (age 0-3 months). A disinfectant agent such as alcohol can also be used for preparing the skin of neonates. Preparation instructions: Remove any oil/lotion/vernix from the contact point on patient s head. Wipe all preparation gel off with an alcohol wipe/pad or a soft dry non-stick cloth (e.g., gauze). - For sensitive/allergic skin, it may be best to use only a soft dry cloth since alcohol can dry out the skin. If the patient suffers from any known allergies e.g., perfume, pay extra attention to the use of disinfectant agents. - Since alcohol may take time to dry, impedances may be slightly higher when using alcohol. Make sure that the alcohol is completely dry before applying conductive gel and electrodes. - Some clinicians prefer not to use alcohol pads/disinfectant agents, but remove the preparation gel with a dry non-stick cloth (e.g., gauze). - If the patient s skin is dry or you are obtaining high impedances, apply a small amount of conductive gel/paste to the skin prior to connecting the surface electrode. This will help to rehydrate the skin and to lower impedances. 2. Mounting the electrodes Always prepare the skin prior to mounting either disposable or reusable electrodes. Some disposable electrodes are pre-gelled (e.g., PEG15), and no further gel is required. Note When mounting pre-gelled disposable electrodes (e.g., PEG15), do not press in the middle of the electrode as gel to be dispersed to the adhesive outer edge causing the electrode to loosen from the skin, causing very high impedances during testing. - Mount the disposable electrode by pressing down around the adhesive outer edge. - If you gently pull on the electrode a few seconds after application, the electrode should remain tightly adhered to the skin. This should ensure very low impedances ( 1kOhm). - Recommended impedance are below or equal to 3kOhms and balanced (e.g., all electrodes should have similar impedance values within 2kOhms). Reusable electrodes are expected to have higher impedance than the disposable electrodes. - For reusable electrodes, it should be possible to achieve impedances in the range of 1-5kOhms. - Always apply a conductive electrode gel/paste (e.g., paste) to all reusable electrodes before mounting. - Use medical tape (e.g., micropore) to hold the reusable electrode cups in place on the skin. Lead is sometimes soldered onto the reusable cup electrodes by a hospital to improve their conductivity; producing lower impedances. Reusable electrodes containing lead are not supplied, because of the hazardous nature of lead. Item No Page 1 of 5

2 Reducing Noise 1. Test Room Parameters The test room and location of the room can greatly effect ABR recordings. The following test room parameters should be aimed for: - A magnetically shielded booth/room (if possible). - A quiet or soundproofed booth or sound treated room. This ensures the patient can relax without disturbances and the stimulus noise is not masked by background noise. - Use of a dedicated ground (isolated socket) for the ABR equipment. - Lights and other equipment not being used should be turned off or unplugged as the patient can work as an antenna and picks up electrical interference from these sources. - Separate equipment cables to reduce interference (e.g., braid electrode cables, keep electrode cables and transducer cables away from each other). In some cases, it may be necessary to find another test location if there is too much ambient or electrical noise in the current test room. Try moving the test bed within the room. It may be placed unknowingly, adjacent to a wall that has hidden cables and electrical sources. 2. Patient Instructions The quality of the ABR recordings depends highly on the state of the patient. If the patient is not physically/mentally relaxed, more unstable, noisy recordings will be seen. Instruct the patient so that: - They are relaxed and calm. - Their eyes are closed and that their face and jaw muscles are relaxed. - They are lying down on a comfortable bed or reclining in a comfortable chair. The duration of an ABR test can be long, so ensure that the patient is as comfortable as possible (use pillows and blankets as needed). Note An upright sitting position should be avoided due to contracted neck/head muscles. - Turn off lights in the test room to avoid electrical interference and to help the patient to relax/go to sleep. Sleeping during recording will provide the lowest noise from the patient, so a sleeping state is preferred if possible. - Test infants and children during sleep is recommended as they cannot be instructed to or find it difficult to relax for the entire test duration. It is important to try and use the same test conditions and parameters for each test when comparing results. 3. Set an appropriate rejection level A recording cannot be collected if the system rejects the signal. - Adjust the rejection level to an appropriate level according to the patient and test type. Typically, ABR recordings can be made using a rejection level of 40µV or less when the patient is relaxed and/or sleeping. - A lower rejection level means a lower amount of noise is recorded during each average. This equates to faster and more accurate recordings. Changing the rejection level The rejection level should be increased until the real time EEG signal (top of the screen) is no longer red (indicating rejection). The rejection level used will depend on the patient and the electrical interference in the test room. A black EEG curve indicates that the system is ready to measure. Item No Page 2 of 5

3 The higher the rejection level value, the more noise is recorded during each average. Therefore, always use the lowest possible rejection level value, without rejection. The level can be adjusted during a recording, by double clicking on the EEG window (EP15/25 only) and adjusting the input level by dragging the horizontal bars. If a high rejection setting is needed, check that electrode impedances are sufficiently low and that the patient is relaxed before starting the test. Muscle tension of the face, back or neck due an uncomfortable or incorrect position will disturb the ABR recordings as these muscles are close to the recording site. 4. Use of a Ground Grounding is crucial for good ABR waves and safe operation. A separate ground dedicated for the ABR equipment should be used. A true ground uses a minimum of three earth rods. The Eclipse s power cord contains a ground lead (typically indicated by yellow and green colors), but often the ground at the test site may not be sufficient. - Always check the wall outlet for a proper ground when establishing an ABR test room. Sometimes the ground lead is found inside the wall outlet, but is not connected to the ground. In these cases where the ground is not connected or even missing, the ABR recordings will be dramatically distorted. - Electrical interference may appear through the ground lead if the wall outlet used is connected to a shared ground (e.g., other wall outlets with electrical equipment connected share the ground). In this case, a dedicated ground wall outlet for the ABR recording equipment should be established. - The ABR system cabinet is connected to the ground lead via an internal capacitor. If the ground lead is not connected, the ABR system will pick up electrical noise/interference. This will be seen on the screen as very large harmonic distortion curves completely overlaying/destroying the ABR curves. - Ground the patient bed if it is made of metal. On the backside of the Eclipse, there is a special ground plug which can be connected to the patient bed. Check the ground for proper and correct function Due to High Voltage, only experienced technicians/ properly trained staff must check and change the ground. To check and verify the ground, various methods can be used. 1. A dedicated ground tester. 2. A voltage/impedance comparison from the wall outlet ground lead to a triangle of earth rods. 3. Ground should have max 8ohm, and 0.5V deviation compared to the true ground. 4. A more simple check is to use a Voltage Meter and measure directly from the wall outlet. Please verify these specifications: a. The Voltage between Phase (Hot) socket and Zero (Neutral) socket must be a stable 230V for Europe /110V for US (country specific). b. Check the Voltage between phase (Hot) socket and Ground socket, 230V for Europe / 110V for US (country specific). The voltage value found in step a, should match the voltage value found in this step (within 5V). If the recorded voltage is much less than the expected voltage (e.g., a voltage reading of 50V for US), the ground is not connected to a true ground, even though you may be able to see the lead in the wall. c. Check the Voltage between Zero (Neutral) and Ground. It must be 0V. If the recorded voltage is much less than the expected voltage, the ground is not connected to a true ground, even though you may be able to see the lead in the wall. Item No Page 3 of 5

4 Reducing noise in the EP15/25 module 1. Optimizing Settings Changing the filter settings can reduce excessive environmental electrical interference. With the EP software, go to File - System setup Auto Protocols tab. For 15ms tests (ABR-15), change the high pass filter to 100Hz 12/oct. Note Using a filter setting like this may reduce the amplitude in the ABR waveforms. However it may be needed if it is impossible to obtain ABR curves without excessive electrical interference. Change the stimulus rate so that it isn t time locked to other electrical interference (e.g., 50/60Hz mains) can reduce noise. For periodic interferences, use the Minimize Interference option. Small random pauses are inserted between stimulus presentations, minimizing the synchronization with electrical interference. These pauses do not influence latency times or in any other manner, change the behavior of ABRs. Please refer to the Eclipse Additional Information for more information. 2. Use Insert Headphones The recording below was carried out using reusable electrodes and headphones. Note the very large spikes before 1ms, especially on the curves at high intensities. Item No Page 4 of 5

5 This is an electrical artifact caused by electrical coupling from the headphones to the input circuit when high sound stimuli intensities are used. To solve this: - Always use insert earphones. - If using headphones they must be shielded. A shielded headset will still produce a small artefact using intensities above 90 db SPL. - Start the recording window after the artifact. Item No Page 5 of 5

EC209 - Improving Signal-To-Noise Ratio (SNR) for Optimizing Repeatable Auditory Brainstem Responses

EC209 - Improving Signal-To-Noise Ratio (SNR) for Optimizing Repeatable Auditory Brainstem Responses EC209 - Improving Signal-To-Noise Ratio (SNR) for Optimizing Repeatable Auditory Brainstem Responses Aaron Steinman, Ph.D. Director of Research, Vivosonic Inc. aaron.steinman@vivosonic.com 1 Outline Why

More information

D C 01/2019 3

D C 01/2019 3 D-0117968-C 01/2019 3 4 D-0117968-C 01/2019 Screw Driver Screw Driver Unplug both the Red & Blue connectors. (see above) Place a small flat head screw driver on the small orange tabs and push down while

More information

CIRCUIT-TEST ELECTRONICS

CIRCUIT-TEST ELECTRONICS USER'S MANUAL Sweep Function Generator with Counter SWF-8030 CIRCUIT-TEST ELECTRONICS www.circuittest.com TABLE OF CONTENTS SAFETY INFORMATION...page 3 INTRODUCTION... 4 SPECIFICATIONS... 5 FRONT PANEL

More information

CHAPTER 7 INTERFERENCE CANCELLATION IN EMG SIGNAL

CHAPTER 7 INTERFERENCE CANCELLATION IN EMG SIGNAL 131 CHAPTER 7 INTERFERENCE CANCELLATION IN EMG SIGNAL 7.1 INTRODUCTION Electromyogram (EMG) is the electrical activity of the activated motor units in muscle. The EMG signal resembles a zero mean random

More information

Bio-Tuner Model BT7. A Consumer Product

Bio-Tuner Model BT7. A Consumer Product Bio-Tuner Model BT7 A Consumer Product CONTENTS INTRODUCTION... 3 COMPLETE UNIT INCLUDES... 3 OPERATIONAL CAUTIONS... 4 GETTING STARTED... 4 HOW TO USE THE BIO-TUNER... 6 How it Should Feel... 8 Typical

More information

LED Thin Frame Fixed Frame Screen User Guide

LED Thin Frame Fixed Frame Screen User Guide LED Thin Frame Fixed Frame Screen User Guide INTRODUCTION INTRODUCTION WARNING - Sharp Edges This product may contain sharp edges, please handle with care. Protective gloves are recommended. WARNING -

More information

Eclipse Specifications

Eclipse Specifications Eclipse Specifications 8104961-1 12/2013 Contents Eclipse Specifications... 1 1.1 Eclipse Software Module Overview...1 1.1.1 EP15/EP25/VEMP Modules...1 1.1.2 TEOAE25 Module...1 1.1.3 DPOAE20 Module...2

More information

rainbow ReSposable Pulse CO-Oximeter Sensor System Training Please see product s Directions for Use for more information 2012 Masimo Corporation

rainbow ReSposable Pulse CO-Oximeter Sensor System Training Please see product s Directions for Use for more information 2012 Masimo Corporation rainbow ReSposable Pulse CO-Oximeter Sensor System Training Learning Objectives At the end of this lesson, the learner will be able to: > Identify key application, inspection and precautionary guidelines

More information

On-Line Cardio Theater Wireless Digital Transmitter Installation and Instruction Manual

On-Line Cardio Theater Wireless Digital Transmitter Installation and Instruction Manual On-Line Cardio Theater Wireless Digital Transmitter Installation and Instruction Manual Full installation instructions accompany your Cardio Theater equipment order. This On-Line version of our Installation/Instruction

More information

EXPERIMENT 5 Bioelectric Measurements

EXPERIMENT 5 Bioelectric Measurements Objectives EXPERIMENT 5 Bioelectric Measurements 1) Generate periodic signals with a Signal Generator and display on an Oscilloscope. 2) Investigate a Differential Amplifier to see small signals in a noisy

More information

Explorer Wiring Kit (assembled)

Explorer Wiring Kit (assembled) Explorer Wiring Kit (assembled) For Vintage, Firestorm & Standard Series Please Read All Instructions Before Beginning. Tools you will need: Soldering Iron (35 watt preferably) Solder Wet Sponge Wire Clippers

More information

Technical Specifications Eclipse

Technical Specifications Eclipse Technical Specifications Eclipse D-0121111-A 2018/06 Contents 1.1 Eclipse Software Module Overview... 1 1.1.1 EP15/EP25/VEMP Modules... 1 1.1.2 TEOAE Module... 2 1.1.3 DPOAE Module... 2 1.1.4 ABRIS Module...

More information

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE. ISO-STIM 01D STIMULUS ISOLATION UNIT ±100 V / ±10 ma, bipolar output

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE. ISO-STIM 01D STIMULUS ISOLATION UNIT ±100 V / ±10 ma, bipolar output OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE ISO-STIM 01D STIMULUS ISOLATION UNIT ±100 V / ±10 ma, bipolar output VERSION 4.0 npi 2014 npi electronic GmbH, Bauhofring 16, D-71732 Tamm, Germany

More information

EE 230 Experiment 10 ECG Measurements Spring 2010

EE 230 Experiment 10 ECG Measurements Spring 2010 EE 230 Experiment 10 ECG Measurements Spring 2010 Note: If for any reason the students are uncomfortable with doing this experiment, please talk to the instructor for the course and an alternative experiment

More information

Human-to-Human Interface

Human-to-Human Interface iworx Physiology Lab Experiment Experiment HN-8 Human-to-Human Interface Introduction to Neuroprosthetics and Human-to-Human Muscle Control Background Set-up Lab Note: The lab presented here is intended

More information

Technical Specifications Eclipse

Technical Specifications Eclipse Technical Specifications Eclipse D-0103651-D 11/2015 Contents 1.1 Eclipse Software Module Overview... 1 1.1.1 EP15/EP25/VEMP Modules... 1 1.1.2 TEOAE25 Module... 2 1.1.3 DPOAE20 Module... 2 1.1.4 ABRIS

More information

APES HD-7700 Version Operator s Training Manual

APES HD-7700 Version Operator s Training Manual APES-14-77 HD-7700 Version Operator s Training Manual Issue A1 09/03 P/N 900599 Performance Design Inc. 2350 East Braniff St. Boise Idaho 83716 This manual contains very important safety information and

More information

This manual is valid for the TM. In TENSity 5000 TENS Stimulator. This user manual is published by Current Solutions, LLC

This manual is valid for the TM. In TENSity 5000 TENS Stimulator. This user manual is published by Current Solutions, LLC INSTRUCTION MANUAL This manual is valid for the TM In TENSity 5000 TENS Stimulator This user manual is published by Current Solutions, LLC Current Solutions, LLC does not guarantee its contents and reserves

More information

5MHz FUNCTION GENERATOR

5MHz FUNCTION GENERATOR 5MHz FUNCTION GENERATOR MODEL GF-8056 User s Manual Elenco TM Electronics, Inc. Copyright 2004 by Elenco TM Electronics, Inc. All rights reserved. 753117 No part of this book shall be reproduced by any

More information

5MHz FUNCTION GENERATOR

5MHz FUNCTION GENERATOR 5MHz FUNCTION GENERATOR MODEL GF-8056 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com User s Manual Elenco TM Electronics, Inc.

More information

2 Interfacing. 2.1 Introduction. The C 411 III pickup is a condenser transducer and therefore needs a power supply. Important!

2 Interfacing. 2.1 Introduction. The C 411 III pickup is a condenser transducer and therefore needs a power supply. Important! 2 Interfacing 2.1 Introduction ( Important! 2.2 C 411 III PP 2.2.1 Connecting to Balanced Inputs Refer to fig. 1. The C 411 III pickup is a condenser transducer and therefore needs a power supply. Using

More information

USER MANUAL. GOLDMUND SR150 2-CHANNEL Universal Power Amplifier

USER MANUAL. GOLDMUND SR150 2-CHANNEL Universal Power Amplifier USER MANUAL GOLDMUND SR150 2-CHANNEL Universal Power Amplifier Congratulations. Thank you for purchasing the Goldmund SR150 2-CHANNEL Universal Power Amplifier. You have acquired the best multi-usage Power

More information

INSTRUCTION MANUAL LCS TX

INSTRUCTION MANUAL LCS TX INSTRUCTION MANUAL LCS TX 4 Channel Transmitter LCS1 Single Channel Transmitter Cardio Theater Inc Service 1-800-776-6695 Sales 1-800-CARDIO-1 1 Introduction CONGRATULATIONS on your choice of this product

More information

APPLICATION NOTE. Overview

APPLICATION NOTE. Overview Application Note 111 APPLICATION NOTE Nerve Conduction Velocity 42 Aero Camino, Goleta, CA 93117 Tel (805) 685-0066 Fax (805) 685-0067 info@biopac.com www.biopac.com 06.05.2018 This application note details

More information

M30 SPOT WELDER INSTRUCTION MANUAL 230V 1PH.

M30 SPOT WELDER INSTRUCTION MANUAL 230V 1PH. M30 SPOT WELDER INSTRUCTION MANUAL 230V 1PH. We have the right to improve and update the machine. The picture and the content are just for your reference. IN20808 2017 Chief Automotive Technologies CO9910.4

More information

400 MHz Passive High-Voltage Probe R&S RT-ZH

400 MHz Passive High-Voltage Probe R&S RT-ZH Manual 400 MHz Passive High-Voltage Probe R&S RT-ZH11 1409.7737.02 Printed in Germany Test and Measurment Manufacturer ROHDE & SCHWARZ For comprehensive information about Rohde and Schwarz, please visit

More information

GOLDMUND MIMESIS SRM2.3 MONO AMPLIFIER

GOLDMUND MIMESIS SRM2.3 MONO AMPLIFIER GOLDMUND MIMESIS SRM2.3 MONO AMPLIFIER 1 GOLDMUND MIMESIS SRM2.3 MONO AMPLIFIER USER MANUAL ATTENTION : No connection or manipulation must be done before reading those instructions. Damage to the amplifier

More information

Power Quality, Earthing And Bonding Oct $4,250 Dubai, UAE. In any of the 5 star hotels. The exact venue will be informed once finalized.

Power Quality, Earthing And Bonding Oct $4,250 Dubai, UAE. In any of the 5 star hotels. The exact venue will be informed once finalized. Training Title POWER QUALITY, EARTHING AND BONDING Training Duration 5 days Training Date Power Quality, Earthing And Bonding 5 04 08 Oct $4,250 Dubai, UAE In any of the 5 star hotels. The exact venue

More information

Application Note 175 Using the STMISOC Stimulus Isolator

Application Note 175 Using the STMISOC Stimulus Isolator APPLICATION NOTE 42 Aero Camino, Goleta, CA 93117 Tel (805) 685-0066 Fax (805) 685-0067 info@biopac.com www.biopac.com 02.14.2018 Application Note 175 Using the The MP160/150 System stimulation features

More information

Neural Function Measuring System MEE-1000A 16/32 ch. Intraoperative Monitoring System

Neural Function Measuring System MEE-1000A 16/32 ch. Intraoperative Monitoring System Neural Function Measuring System MEE-1000A 16/32 ch. Intraoperative Monitoring System Neural function monitoring during operation for safer surgery For more than 60 years, healthcare providers worldwide

More information

Dear Valued Customer,

Dear Valued Customer, Dear Valued Customer, Thank you for choosing Listen! All of us at Listen are dedicated to provide you with the highest quality products available. We take great pride in their outstanding performance because

More information

How To... Commission an Installed Sound Environment

How To... Commission an Installed Sound Environment How To... Commission an Installed Sound Environment This document provides a practical guide on how to use NTi Audio instruments for commissioning and servicing Installed Sound environments and Evacuation

More information

TM-800 Main Station. Instruction Manual. TELIKOU Systems All Rights Reserved

TM-800 Main Station. Instruction Manual. TELIKOU Systems All Rights Reserved Intercom System TM-800 Main Station Instruction Manual TELIKOU Systems All Rights Reserved I. Introduction Thank you for choosing TELIKOU intercom product. TM-800 main station is suitable for television

More information

Installation and Service Manual

Installation and Service Manual LCD Attachment Installation and Service Manual 2 Table of Contents Parts List...2 Hardware Kits...3 Bike, Cross Trainer and Stepper Start...4 Steps in Assembling the Bracket...5 Installation Instructions

More information

CMA-100. Counter Measures Amplifier. Owner s Guide

CMA-100. Counter Measures Amplifier. Owner s Guide CMA-100 Counter Measures Amplifier Owner s Guide INTRODUCTION: Thank you for purchasing the CMA-100 Countermeasures Amplifier. When doing a Counter-surveillance investigation, it is important to analyze

More information

Safety Warnings Features Specifications Instrument Layout Operation Preparation AC Current Measurement How to Use Peak Hold Function How to Use The

Safety Warnings Features Specifications Instrument Layout Operation Preparation AC Current Measurement How to Use Peak Hold Function How to Use The Safety Warnings Features Specifications Instrument Layout Operation Preparation AC Current Measurement How to Use Peak Hold Function How to Use The Frequency Selector Switch How to Use Data Hold Function

More information

GFL-1000 User Manual Ground Fault Locator

GFL-1000 User Manual Ground Fault Locator GFL-Series User Manual V1.1 GFL-1000 User Manual Ground Fault Locator Contents Contents... 1 1 Declaration of Conformity... 3 2 Introduction... 3 3 Equipment Information... 3 3.1 Safety Precautions...

More information

USER MANUAL. GOLDMUND SRM250 Power Amplifier

USER MANUAL. GOLDMUND SRM250 Power Amplifier USER MANUAL GOLDMUND SRM250 Power Amplifier Congratulations. Thank you for purchasing the Goldmund SRM250 Power Amplifier. You have acquired the best Analog Power Amplifier ever made for professional and

More information

Standard Operating Procedure for Medtronic continuous glucose monitor

Standard Operating Procedure for Medtronic continuous glucose monitor Standard Operating Procedure for Medtronic continuous glucose monitor Effective date: 26.07.2017 Review due date: 20.04.2019 Original Author Name: Richard Metcalfe Position: PhD Student Date: 05.12.2012

More information

ReSound Micro and Multi Mic

ReSound Micro and Multi Mic Tip for use of FAQ: Click on questions to go to answer. Setup & Configuration How do I pair the hearing aids to the Micro and Multi Mic?... 3 How many hearing aids can the Micro/Multi Mic be paired with?...

More information

Headset Intercom System. Operating Instructions

Headset Intercom System. Operating Instructions Headset Intercom System Model C1025 Operating Instructions Headset and Transceiver Pack Base Station Model C1025 Table of Contents Intended Use...iii FCC Information...iii Service...iii System Descriptions...1

More information

Telecaster Wiring Kits Please Read All Instructions Before Beginning. Tools you will need: Soldering tips: Removing Current Wiring: Step 1. Step 2.

Telecaster Wiring Kits Please Read All Instructions Before Beginning. Tools you will need: Soldering tips: Removing Current Wiring: Step 1. Step 2. Telecaster Wiring Kits Please Read All Instructions Before Beginning. Tools you will need: Soldering Iron (35 watt preferably) Solder Wet Sponge Wire Clippers Wire Strippers 3/8 Drill Bit 5/32 Drill Bit

More information

Device Interconnection

Device Interconnection Device Interconnection An important, if less than glamorous, aspect of audio signal handling is the connection of one device to another. Of course, a primary concern is the matching of signal levels and

More information

CONTENTS Preparation Functions and Indications Operation

CONTENTS Preparation Functions and Indications Operation CONTENTS Features 3 Preparation Parts of the detector 4 Assembling the detector 4 Adjusting the search coil 6 Installing the batteries 6 Using the headphones 7 Functions and Indications Parts of the control

More information

Safety Warnings Features Specifications Instrument Layout Operation Preparation AC Current Measurement How to Use Peak Hold Function How to Use The

Safety Warnings Features Specifications Instrument Layout Operation Preparation AC Current Measurement How to Use Peak Hold Function How to Use The Safety Warnings Features Specifications Instrument Layout Operation Preparation AC Current Measurement How to Use Peak Hold Function How to Use The Frequency Selector Switch How to Use Data Hold Function

More information

Golden Mask Deep Hunter LE

Golden Mask Deep Hunter LE Golden Mask Deep Hunter LE Golden mask Deep Hunter LE is a pulse induction detector, designed for easy detection of deeply buried large metal objects (larger than 8 cm or 3 ) with LED indication for the

More information

Flash Stamp Machine T1511M User Manual

Flash Stamp Machine T1511M User Manual Flash Stamp Machine T1511M User Manual Declaration of conformity (Europe only) We, Trodat GmbH Linzer Straße 156 A-4600 Wels hereby declare that the Flash Stamp Machine model T1511M is CE certified respectively

More information

Non-contact Forehead IR Thermometer

Non-contact Forehead IR Thermometer User s Manual Non-contact Forehead IR Thermometer Model IR200 Introduction Congratulations on your purchase of the Model IR200 IR Thermometer. This thermometer is intended for scanning groups of individuals

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Agilent E7400 A-series EMC Analyzers, Precompliance Systems, and EMI Measurement Software E7401A, E7402A E7403A, E7404A

More information

GOLDEN MASK DEEP HUNTER LE

GOLDEN MASK DEEP HUNTER LE GOLDEN MASK DEEP HUNTER LE Golden mask Deep Hunter LE is a pulse induction detector, designed for easy detection of deeply buried larger metal objects (such sizes larger than 8 centimeters) with LED indication

More information

Drill INSTRUCTION MANUAL. WARNING: For your personal safety, READ and UNDERSTAND before using. SAVE THESE INSTRUCTIONS FOR FUTURE 1 REFERENCE.

Drill INSTRUCTION MANUAL. WARNING: For your personal safety, READ and UNDERSTAND before using. SAVE THESE INSTRUCTIONS FOR FUTURE 1 REFERENCE. ENGLISH (Original instructions) INSTRUCTION MANUAL Drill 6411 6412 6413 007894 DOUBLE INSULATION WARNING: For your personal safety, READ and UNDERSTAND before using. SAVE THESE INSTRUCTIONS FOR FUTURE

More information

CMA-100. User Manual. Counter Measures Amplifier

CMA-100. User Manual. Counter Measures Amplifier CMA-100 Counter Measures Amplifier User Manual Research Electronics International, LLC 455 Security Drive, Cookeville, TN 38506 U.S.A. (800) 824-3190 (US Only) +1 931-537-6032 www.reiusa.net Copyright

More information

OPERATOR S MANUAL FOR DMS 300-4A HOLTER ECG RECORDER

OPERATOR S MANUAL FOR DMS 300-4A HOLTER ECG RECORDER OPERATOR S MANUAL FOR DMS 300-4A HOLTER ECG RECORDER WARNING Only a physician can order a Holter ECG test. WARNING Only the ordering physician can decide on the application technique used for affixing

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precautions should always be taken, including the following: Read all instructions before using this appliance. DANGER To reduce

More information

B. Equipment. Advanced Lab

B. Equipment. Advanced Lab Advanced Lab Measuring Periodic Signals Using a Digital Oscilloscope A. Introduction and Background We will use a digital oscilloscope to characterize several different periodic voltage signals. We will

More information

ATD AMP Variable Speed Reciprocating Saw Owner s Manual

ATD AMP Variable Speed Reciprocating Saw Owner s Manual ATD-10535 7 AMP Variable Speed Reciprocating Saw Owner s Manual Manufactured in China To ATD Tools, Inc. Specifications TECHNICAL SPECIFICATIONS Voltage: 120V Frequency: 60Hz Power input: 7 Amps No load

More information

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES TABLE OF CONTENTS / EN TITLE TABLE OF CONTENTS PAGE 1. SAFETY INFORMATION... 1 2. TECHNICAL SPECIFICATIONS... 2 3. PARTS & CONTROLS...

More information

PHYSIOFLOW Q-LINK TM

PHYSIOFLOW Q-LINK TM PHYSIOFLOW Q-LINK TM Service Manual Thursday, 20 October 2016 First placing on the market : 18 January 2012 User Manual PhysioFlow Q-Link 1/17 Table of contents 1. General Information... 3 About this manual...

More information

Warning: Electrical Hazard... 3 Safety Instruction Sheet for STG Product Overview What s in the box?... 4

Warning: Electrical Hazard... 3 Safety Instruction Sheet for STG Product Overview What s in the box?... 4 STG-2412 User Guide Warning: Electrical Hazard... 3 Safety Instruction Sheet for STG-2412... 3 Product Overview... 4 What s in the box?... 4 Using STG-2412 for Mixing, Processing, and Recording... 5 Software

More information

2005 ODU Point & Peak Job Aid

2005 ODU Point & Peak Job Aid Summary This Job Aid covers: Preparing the Antenna for Pointing and Peaking Point Elevation Set the Skew Point Azimuth Peak Azimuth Peak Elevation Push/Pull Test This Job Aid supports all Technician audiences.

More information

Single Channel Radio Mic System USER MANUAL. WMU-116-H (Hand Held) WMU-116-B (Belt Pack) Single Channel Radio Mic System

Single Channel Radio Mic System USER MANUAL. WMU-116-H (Hand Held) WMU-116-B (Belt Pack) Single Channel Radio Mic System Single Channel Radio Mic System USER MANUAL WMU-116-H (Hand Held) WMU-116-B (Belt Pack) Single Channel Radio Mic System Welcome Thank you for choosing Hill Audio for your sound system. To make sure that

More information

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE EXT-02 B EXTRACELLULAR AMPLIFIER

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE EXT-02 B EXTRACELLULAR AMPLIFIER OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE EXT-02 B EXTRACELLULAR AMPLIFIER VERSION 1.3 npi 2014 npi electronic GmbH, Bauhofring 16, D-71732 Tamm, Germany Phone +49 (0)7141-9730230; Fax: +49

More information

Multifunction AC/DC Voltage Tester

Multifunction AC/DC Voltage Tester User Manual Multifunction AC/DC Voltage Tester Model 20250-59 THE STANDARD IN PRECISION MEASUREMENT 1065DGMAN_20250-59 DS multifunctional voltage tester.indd 1 8/8/2017 1:37:47 PM Introduction The Digi-Sense

More information

FM Stereo FM-AM Tuner

FM Stereo FM-AM Tuner 3-861-346-12(1) FM Stereo FM-AM Tuner Operating instructions ST-SA50ES 1999 by Sony Corporation 1 GB WARNING To prevent fire or shock hazard, do not expose the unit to rain or moisture. This symbol is

More information

OWNER S MANUAL. SimmonsDrums.net

OWNER S MANUAL. SimmonsDrums.net SimmonsDrums.net OWNER S MANUAL TABLE OF CONTENTS WELCOME AND CONGRATULATIONS!... 3 FRONT PANEL... 4 FEATURES...5 SPECIFICATIONS...6 SIGNAL FLOW DIAGRAM...6 WARRANTY...7 2 WELCOME AND CONGRATULATIONS!

More information

Making a Recording in the Booth

Making a Recording in the Booth Making a Recording in the Booth From UW Phonetics/Sociolinguistics Lab Wiki This page is a quick start guide to making a recording in the soundproof booth. Before continuing with the guide, check to ensure

More information

Installation Instructions GENERAL SAFETY INFORMATION FOR MAGNETS CAUTION WHAT S IN THE BOX

Installation Instructions GENERAL SAFETY INFORMATION FOR MAGNETS CAUTION WHAT S IN THE BOX G U I T A R S U P P O R T S Installation Instructions GENERAL SAFETY INFORMATION FOR MAGNETS The magnets supplied with your Barnett Guitar Support are very strong and pose potential safety hazards. i.

More information

HQ Hideaway. Installation and Operation Version 2.2, April 2015 Part # QT40100

HQ Hideaway. Installation and Operation Version 2.2, April 2015 Part # QT40100 HQ Hideaway Installation and Operation Version 2.2, April 2015 Part # QT40100 Copyright 2015 Handi Quilter, Inc. All rights reserved. Printed in the U.S.A. Table of Contents Page Overview 3 To install

More information

ENGLISH (Original instructions) INSTRUCTION MANUAL. Drill DOUBLE INSULATION. IMPORTANT: Read Before Using.

ENGLISH (Original instructions) INSTRUCTION MANUAL. Drill DOUBLE INSULATION. IMPORTANT: Read Before Using. ENGLISH (Original instructions) INSTRUCTION MANUAL Drill 64 642 643 007894 DOUBLE INSULATION IMPORTANT: Read Before Using. ENGLISH (Original instructions) SPECIFICATIONS Model 64 642 643 Capacities Steel

More information

D-808. FM Stereo/LW/MW/SW-SSB AIR RDS Synthesized Receiver

D-808. FM Stereo/LW/MW/SW-SSB AIR RDS Synthesized Receiver XHDATA D-808 FM Stereo/LW/MW/SW-SSB AIR RDS Synthesized Receiver WARNING Do not expose this appliance to rain or moisture Do not submerge or expose to water Protect from high humidity and rain Only operate

More information

Nash Chandelier Assembly and Installation Instructions

Nash Chandelier Assembly and Installation Instructions CAUTION: Nash Chandelier Assembly and Installation Instructions BEFORE INSTALLING FIXTURE, MAKE SURE THE POWER TO THE CIRCUIT IS TURNED OFF AT THE MAIN FUSE BOX / CIRCUIT BREAKER UTILITY BOX. Important

More information

USER MANUAL. GOLDMUND TELOS 1000 Universal Power Amplifier

USER MANUAL. GOLDMUND TELOS 1000 Universal Power Amplifier USER MANUAL GOLDMUND TELOS 1000 Universal Power Amplifier Thank you for purchasing the GOLDMUND TELOS 1000. You have acquired the best Universal Power Amplifier ever made for professional and domestic

More information

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER This manual contains proprietary information, which is protected by copyright. All rights are reserved. No part of this manual

More information

PDWM4400 VHF WIRELESS SYSTEM PDWM4400 VHF WIRELESS SYSTEM OPERATION MANUAL

PDWM4400 VHF WIRELESS SYSTEM PDWM4400 VHF WIRELESS SYSTEM OPERATION MANUAL A.Overall system Oscillation mode: Quartz controlled Carrier Frequency Range: VHF 169-270MHz Stability: 0.005% Max Deviation: 56KHz with level limiting Dynamic Range: 100dB S/N Ratio: 80dB T.H.D: 0.5%

More information

User s Manual for Integrator Short Pulse ISP16 10JUN2016

User s Manual for Integrator Short Pulse ISP16 10JUN2016 User s Manual for Integrator Short Pulse ISP16 10JUN2016 Specifications Exceeding any of the Maximum Ratings and/or failing to follow any of the Warnings and/or Operating Instructions may result in damage

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

Powermatic Model 31A Combination Belt-Disk Sander

Powermatic Model 31A Combination Belt-Disk Sander OPERATING PROCEDURE FOR: Powermatic Model 31A Combination Belt-Disk Sander INTRODUCTION: The combination belt-disk sander is used to sand the edges of boards. It can be used to smooth the edge or to remove

More information

P A T. Play Dome. Product features may vary from picture above.

P A T. Play Dome. Product features may vary from picture above. L E A R N I N G P A T T E R N S Play Dome Product features may vary from picture above. Model Number: B0003 Please keep this instruction sheet for future reference, as it contains important information.

More information

Active Transmitter Combiner 8:1 AC 3200-II. Instruction manual

Active Transmitter Combiner 8:1 AC 3200-II. Instruction manual Active Transmitter Combiner 8:1 AC 3200-II Instruction manual Contents Contents Important safety instructions... 2 The AC 3200-II active transmitter combiner 8:1... 4 Delivery includes... 4 Connection

More information

2009 ODU Point and Peak Job Aid

2009 ODU Point and Peak Job Aid Summary This Job Aid covers: Preparing the Antenna for Pointing and Peaking Point Elevation Set the Skew Point Azimuth Peak Azimuth Peak Elevation Push/Pull Test This Job Aid supports all Technician audiences.

More information

Lab E5: Filters and Complex Impedance

Lab E5: Filters and Complex Impedance E5.1 Lab E5: Filters and Complex Impedance Note: It is strongly recommended that you complete lab E4: Capacitors and the RC Circuit before performing this experiment. Introduction Ohm s law, a well known

More information

TETRIS 1000 High Impedance Active Probe. Instruction Manual

TETRIS 1000 High Impedance Active Probe. Instruction Manual TETRIS 1000 High Impedance Active Probe Instruction Manual Copyright 2015 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications

More information

E-800 power amplifier. user manual

E-800 power amplifier. user manual E-800 power amplifier user manual Musikhaus Thomann e.k. Treppendorf 30 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 03.06.2013 Table of contents

More information

Vinyl Cutter Instruction Manual

Vinyl Cutter Instruction Manual Vinyl Cutter Instruction Manual 1 Product Inventory Inventory Here is a list of items you will receive with your vinyl cutter: Product components (Fig.1-4): 1x Cutter head unit complete with motor, plastic

More information

E. Front Stretcher 1 pc. 1 pc. 1 pc. M8x38 Wood Screw (long) 1 pc. (+1 extra) M4x19 Wood Screw (short) 12 pcs. (+1 extra)

E. Front Stretcher 1 pc. 1 pc. 1 pc. M8x38 Wood Screw (long) 1 pc. (+1 extra) M4x19 Wood Screw (short) 12 pcs. (+1 extra) 88 5134 26 Bench Carefully remove all the parts from the carton and place them individually on a soft cloth to prevent scratches or other damage. Carefully and strictly follow these assembly instructions

More information

ENGLISH (Original instructions) INSTRUCTION MANUAL. Drill MT600 MT601 DOUBLE INSULATION. IMPORTANT: Read Before Using.

ENGLISH (Original instructions) INSTRUCTION MANUAL. Drill MT600 MT601 DOUBLE INSULATION. IMPORTANT: Read Before Using. ENGLISH (Original instructions) INSTRUCTION MANUAL Drill MT600 MT60 003635 DOUBLE INSULATION IMPORTANT: Read Before Using. ENGLISH (Original instructions) SPECIFICATIONS Model MT600 MT60 Capacities Steel

More information

SM 50Ak. 2 way nearfield active monitor owners manual.

SM 50Ak. 2 way nearfield active monitor owners manual. 2 way nearfield active monitor owners manual www.sonodyne.com Introduction Safety Unpacking Fig 1 & 2 INTRODUCTION Congratulations on your purchase of the near field active studio monitor. The has all

More information

USER. manual. Falco Systems WMA-100. High Voltage Amplifier DC - 500kHz

USER. manual. Falco Systems WMA-100. High Voltage Amplifier DC - 500kHz USER manual Falco Systems WMA-100 High Voltage Amplifier DC - 500kHz Falco Systems WMA-100, High Voltage Amplifier DC - 500kHz High voltage: 20x amplification up to +175V and -175V output voltage with

More information

Premium Light Filtering Sheer Shade

Premium Light Filtering Sheer Shade Premium Light Filtering Sheer Shade Installation Instructions Email: customerservice@blindster.com Call us: (888) 256-8672 Mon - Fri 8am - 7pm (CT) Congratulations on purchasing a Premium Light Filtering

More information

POWERED MONITOR SPEAKER MSP10STUDIO

POWERED MONITOR SPEAKER MSP10STUDIO POWERED MONITOR SPEAKER MSP10STUDIO Owner s manual Mode d emploi Bedienungsanleitung Manual de instrucciones M Thank you for purchasing the Yamaha MSP10STUDIO powered monitor speaker system. The MSP10STUDIO

More information

PRODUCT SHEET IMPORTANT SAFETY NOTES!

PRODUCT SHEET IMPORTANT SAFETY NOTES! STMISO STIMULUS ISOLATION ADAPTERS See also: Stimulator Setup notes in AcqKnowledge Software Guide BIOPAC offers three stimulus isolation adapters: STMISOC constant current or constant voltage (5X / 10X)

More information

CAUTION : TO PREVENT ELECTRIC SHOCK, MATCH WIDE BLADE OF PLUG TO WIDE SLOT, FULLY INSERT.

CAUTION : TO PREVENT ELECTRIC SHOCK, MATCH WIDE BLADE OF PLUG TO WIDE SLOT, FULLY INSERT. BSR-1 The Lightning flash with arrowhead symbol, with an equilateral triangle is intended to alert the user of the presence of uninsulated dangerous voltage within the product s enclosure that may be of

More information

Soft, Comfortable Polymer Dry Electrodes for High Quality ECG and EEG Recording

Soft, Comfortable Polymer Dry Electrodes for High Quality ECG and EEG Recording Soft, Comfortable Polymer Dry Electrodes for High Quality ECG and EEG Recording Yun-Hsuan Chen 1,2 (Yun-Hsuan.Chen@imec.be), Maaike Op de Beeck 1, Luc Vanderheyden 3, Evelien Carrette 4, Vojkan Mihajlovic

More information

DVM1190 DIGITAL MULTIMETER

DVM1190 DIGITAL MULTIMETER DIGITAL MULTIMETER 1. Introduction Thank you for buying the. This digital multimeter has a large LCD, a data-hold function and a backlight. The device uses a very practical safety mechanism that keeps

More information

Linear. Headphone amplifier / Single Source Preamp. User manual

Linear. Headphone amplifier / Single Source Preamp. User manual Linear Headphone amplifier / Single Source Preamp User manual Lehmannaudio Manual Linear - page 2 - Dear customer, congratulations for buying the Lehmannaudio Linear. You will be rewarded with the best

More information

KANEKA OLED Lighting Module SL (LE-01L, LE-02L, LE-03L, LE-01H, LE-02H, LE-03H) Instruction Manual

KANEKA OLED Lighting Module SL (LE-01L, LE-02L, LE-03L, LE-01H, LE-02H, LE-03H) Instruction Manual KANEKA OLED Lighting Module SL (LE-01L, LE-02L, LE-03L, LE-01H, LE-02H, LE-03H) Instruction Manual Safety Information p. 2 1 Product Overview p. 6 2 Connections and Wiring (when dimming is required) p.

More information

HAWK5000 Operators Manual

HAWK5000 Operators Manual HAWK5000 Operators Manual Keison Products P.O. Box 2124, Chelmsford CM1 3UP, England Tel: +44 (0) 1245 600560 Fax: +44 (0) 1245 600030 Email: sales@keison.co.uk www.keison.co.uk KANE INTERNATIONAL LIMITED

More information

USER'S GUIDE. EcoQuest International 310 T. Elmer Cox Drive Greeneville, TN (423) Setup. Operation. Specifications.

USER'S GUIDE. EcoQuest International 310 T. Elmer Cox Drive Greeneville, TN (423) Setup. Operation. Specifications. USER'S GUIDE Setup Operation Specifications Warranty (43) 638-746 CAUTION: Read manual carefully for proper procedures and operation. CONTENTS SPECIFICATIONS Specifications...............................................................3

More information

EECE Circuits and Signals: Biomedical Applications. Lab ECG I The Instrumentation Amplifier

EECE Circuits and Signals: Biomedical Applications. Lab ECG I The Instrumentation Amplifier EECE 150 - Circuits and Signals: Biomedical Applications Lab ECG I The Instrumentation Amplifier Introduction: As discussed in class, instrumentation amplifiers are often used to reject common-mode signals

More information

King Cloud III. Warning. Obstruction Detection. Instructions for Reclining Sofas

King Cloud III. Warning. Obstruction Detection. Instructions for Reclining Sofas Instructions for Reclining Sofas Warning Do not sit on footrest when in open reclined/extended position. MAXIMUM LOAD 15 KG. Always RETRACT FOOTREST prior to standing. Obstruction Detection IF THE RECLINER

More information