RADIATED MICROWAVES. Application. Working frequency. 6 GHz Band C 6 GHz Band C. Working temperature C C.

Size: px
Start display at page:

Download "RADIATED MICROWAVES. Application. Working frequency. 6 GHz Band C 6 GHz Band C. Working temperature C C."

Transcription

1

2 RADIATED MICROWAVES The instrument antenna sends tight electromagnetics pulses on base band 6 GHz (C-band). These pulses are irradiated and then reflected, from the product surface to be measured and received back by the same antenna. A method of time elongation, allows the assessment of the time of fl ight which, by its nature, is particularly short, to be able to calculate with accurancy the distance and hence the level of the product to be measured. Dust, vapors, high temperatures and pressures are well tolerated and allow the use of units in critical conditions. An advanced computerized system by envelope curve and the possibility to map the false echo curve allow to improve the measurement in critical conditions. Thanks to the two-wire technology (2-wire) and HART communication makes the installation, the commissioning and the use of the units is very simple and intuitive. Application RPL51 liquids RPL52 liquids Working frequency Working temperature Process pressure Range of measurement Antenna material Process connection Process connection material Accuracy Poer supply 6 GHz Band C 6 GHz Band C C C -1 3 bar bar 30 m 30 m PP or PTFE PTFE G 1½ fl ange DN PN 16 PVDF SS 316 L with PTFE coated ± 10 mm ± 10 mm 24 Vdc / 230 Vac 24 Vdc / 230 Vac Protection IP 67 / sensor IP68 IP 67 / sensor IP68 Output signal 2/4 wires 4 20 ma Hart 2/4 wires 4 20 ma Hart 28 - misura level measure di livello

3 LEVEL RPL55 RPL56 RPL57 Application liquids liquids liquids Working frequency 26 GHz Band K 26 GHz Band K 26 GHz Band K Working temperature C C C Process pressure -1 3 bar bar -1 5 bar Range of measurement 10 m 30 m 20 m Antenna material PVDF PTFE / AISI 316 L PTFE Process connection G 1½ G 1½ / fl ange DN DN Process connection material PVDF AISI 316 / PP / PTFE AISI 316 / PTFE Accuracy ± 5 mm ± 3 mm ± 3 mm Poer supply 24 Vdc / 230 Vac 24 Vdc / 230 Vac 24 Vdc / 230 Vac Protection IP67 IP67 IP67 Output signal 2/4 wires 4 20 ma Hart 2/4 wires 4 20 ma Hart 2/4 wires 4 20 ma Hart Atex yes yes yes RPL58 RPL59 RPL61 Application solids / powders liquids Working frequency 26 GHz Banda K 26 GHz Band K Working temperature C C Process pressure bar atmospheric Range of measurement 70 m 15 m 30 / 70 m Antenna material PTFE / SS 316 L PA66 / aluminium PA66 coated Process connection G 1½ / fl ange DN bracket / G1 Process connection material SS 316 / PP / PTFE SS 316 / PP Accuracy ± 15 mm ± 10 mm ± 3 mm Poer supply 24 Vdc / 230 Vac 24 Vdc Protection IP67 IP66 Output signal 2/4 wires 4 20 ma Hart 2 wires 4 20 ma Hart Atex yes yes The antenna of the instrument sends tight electromagnetics pulses on base band 26 GHz (K-band). These pulses are irradiated by antenna and then refl ected, at least in part, from the surface of the product to be measured and received back by the same antenna. A method of time elongation, allows the assessment of the time of flight which, by its nature, is particularly short, to be able to calculate with accurancy the distance and hence the level of the product to be measured. The K-band, with a frequency of electromagnetic waves of 26 GHz, allows the detection of the products surface whose dielectric constant is low.on the other hand it is not advisable to use in the presence of water vapor or conductive or damp dusts

4 RPL51 Level Transmitters by continuous pulsed radar without contact with the product Measuring range up to 30 m Measurement accuracy: ± 10 mm High temperature and pressure of process Non intrusive system application is now preferred in the level measurements fi eld. For this reason SGM-LEKTRA developed RPL51 unity to best meet the GENERAL-PURPOSE application requests. RPL51 is a radar sensor for continuous measurement liquids, also chemically aggressive, in standard process conditions. Suitable for level measurement in tanks with 1 ½ G threaded connection. The slim rod antenna allow the installation into standpipes. TECHNICAL FEATURES Frequency C group (6.3GHz) Housing / Antenna material aluminum / SS316L; PTFE / PP Mechanical installation threaded G 1½ A IP rating IP67/IP68 (Sensor) Electrical connection Terminals Working temperature Antenna PTFE C Antenna PP C Pressure -1 3 bar Power supply 24Vdc; 230Vac Analog output 4 20mA Digital communication HART Measure range 30 mt Accuracy ±10mm Risolution 1mm. Calibraton 4 buttons or via HART Warm up 5 minuts Display Plug-in display/keyboard 4 buttons matrix LCD 30 - misura level measure di livello

5 LEVEL RPL51 Version P Standard Radar level transmitter Micro-waves pulse group C For liquids measurement also with strong erosive products Max. distance: 30m Accuracy: ±10mm Process pressure: -1,0 3bar Conic antenna length: 270mm Antenna shape / Material / Process temperature A Mono-pole / PP / C B Mono-pole / PTFE / C Antenna extension (blind zone H) A 98mm (standard) B 148mm C 198mm D 248mm E 298mm F 348mm Z Special Process connection / Material GP Thread G1" ½ / PVDF (PN3) ZZ Special Electronic preamplifier A None B 4 20mA HART (2-wire); 24Vdc C 4 20mA HART(4-wire); 24Vdc D 4 20mA HART(4-wire); 230Vac Housing / Housing protection / Antenna protection D Aluminum 2 chambers (for 4-wire versions) / IP67 / IP68 G SS316L / IP67 / IP68 U Aluminum with transparent cap / IP67 / IP68 Z Special Cable entry M M20x1,5 Keyboard/display programming module VL602 A Yes X No

6 RPL52 Level Transmitters by continuous pulsed radar without contact with the product Measuring range up to 30 m Measurement accuracy: ± 10 mm High temperature and pressure of process RPL52 is a radar sensor for continuous measurement in liquids, also chemically aggressive, standard process conditions. Suitable for level measurement in tanks with 1 ½ G threaded connection. The slim rod antenna allows installation even into standpipes. TECHNICAL FEATURES Frequency C group (6.3GHz) Housing / Antenna material aluminum / SS316L; PTFE Mechanical installation fl ange DN50/80/100/150 PN16 IP rating IP67/IP68 (Sensor) Electrical connection Terminals Working temperature Antenna PTFE C Pressure bar Power supply 24Vdc; 230Vac Analog output 4 20mA Digital communication HART Measure range 30 mt Accuracy ±10mm Risolution 1mm. Calibraton 4 buttons or via HART Warm up 5 minuts Display Plug-in display/keyboard 4 buttons matrix LCD 32 - misura level measure di livello

7 LEVEL RPL52 Version P Standard Radar level transmitter Micro-waves pulse group C For liquids measurement also with strong erosive products Max. distance: 30m Accuracy: ±10mm Process pressure: -1,0 16bar Conic antenna extension: 270mm Antenna shape / Material / Process temperature B Mono-pole / PTFE / C Antenna extension (blind zone H) A 85mm (standard) B 135mm C 185mm D 235mm E 285mm F 335mm Z Special Process connection / Material FC PTFE protected flange DN50 PN16 / SS316L FD PTFE protected flange DN80 PN16 / SS316L FE PTFE protected flange DN100 PN16 / SS316L FK PTFE protected flange DN150 PN16 / SS316L ZZ Special Electronic preamplifier A None B 4 20mA HART (2-wire); 24Vdc C 4 20mA HART (4-wire); 24Vdc D 4 20mA HART (4-wire); 230Vac Housing / Housing protection / Antenna protection D Aluminum 2 chambers (for 4-wire versions) / IP67 / IP68 G SS316L / IP67 / IP68 U Aluminum with transparent cap / IP67 / IP68 Z Special Cable entry M M20x1,5 Keyboard/display programming module VL602 A Yes X No

8 RPL55 Continuous level measurement without contact for liquids, pastes and slurries Range 10 m Process pressure 3 bar 2 /4 wires technology Pulse Radar at 26 GHz (K-band) Display of alphanumeric level measurement and of the echo signal curve ATEX RPL55 is a radar sensor for continuous measurement in liquids, also chemically aggressive, in standard conditions. Suitable for level measurement in tanks with 1 ½ G threaded connection. The short PVDF antenna allows installation in standpipes and small tanks. TECHNICAL FEATURES Frequency K group (26GHz) Housing / Antenna material aluminum; PVDF Mechanical installation threaded G 1½ IP rating IP67/IP68 (Sensor) Electrical connection Terminals Working temperature Antenna PVDF C Pressure -1 3 bar Power supply 24Vdc; 230Vac Certification ATEX Analog output 4 20mA Digital communication HART Measure range 10 mt Accuracy ±10mm Risolution 1mm. Calibraton 4 buttons or via HART Warm up 5 minuts Display Plug-in display/keyboard 4 buttons matrix LCD 34 - misura level measure di livello

9 LEVEL RPL55 Radar level transmitter Micro-waves pulse 26GHz group K For liquids measurement also with strong erosive products Max distance: 10m Accuracy: ±5mm Process pressure: -1 3bar Version I ATEX II 1 G/D Ex ia IIC T6...3 Ga / Ex ia IIIC T76 C...T146 C Da - only with G housing and B electronic P Standard Antenna shape / Material / Process temperature B Mono-pole / PVDF / C Process connection / Material GP Thread G 1"½ / PVDF ZZ Special Non sensitive part (for nozzle mounting) A 100 mm B 200 mm Electronic preamplifier A None B 4 20mA HART (2-wire); 24Vdc - compulsory for ATEX version C 4 20mA HART (4-wire); 24Vdc D 4 20mA HART (4-wire); 230Vac Housing / Housing protection / Antenna protection D Aluminum 2 chambers (for 4-wire versions) / IP67 / IP68 G SS316L / IP67 / IP68 - compulsory for ATEX version U Aluminum with transparent cap / IP67 / IP68 Z Special Cable entry M M20x1,5 Keyboard/display programming module VL602 A Yes X No

10 RPL56 Continuous level measurement without contact for solids, liquids, pastes and slurries Range 30 m Process pressure 40 bar 2 /4 wires technology Pulse Radar at 26 GHz (K-band) ATEX RPL56 is a radar sensor for liquids continuous measurement. Suitable for application in storage and process tanks, also in hard working conditions. Suitable for level measurement in tanks with 1 ½ G threaded or fl anged connection. The different antenna models and the wide temperature and pressure ranges make the RPL56 radar sensor the optimal solution for nearly all kind of application. TECHNICAL FEATURES Frequency K group (26GHz) Housing / Antenna material aluminum; SS316L Mechanical installation threaded G 1½; 1 ½ NPT IP rating IP67/IP68 (Sensor) Electrical connection Terminals Working temperature C / C / C Pressure -1 a 40 bar; 1 a 400 bar Power supply 24Vdc; 230Vac Certification ATEX Analog output 4 20mA Digital communication HART Measure range 30 mt Accuracy ±3mm Risolution 1mm. Calibraton 4 buttons or via HART Warm up 5 minuts Display Plug-in display/keyboard 4 buttons matrix LCD 36 - misura level measure di livello

11 LEVEL RPL56 Radar level el transmitter Micro-waves pulse 26GHz group K For liquid storage or process applications Max distance: 30m Accuracy: ±3mm Process pressure: -1 40bar Version I ATEX II 1 G/D Ex ia IIC T6...3 Ga / Ex ia IIIC T76 C...T146 C Da - only with G housing and B electronic P Standard Antenna shape / Material B Horn antenna Ø48mm / SS316L (only applicable for installation with standpipe) C Horn antenna Ø78mm / SS316L (only applicable for installation with standpipe) H Horn antenna Ø98mm / SS316L J Horn antenna Ø123mm / SS316L Z Special Process connection / Material GA Thread 1" ½ NPT / SS316L ( C) GC Thread G 1" ½ with cooling fin / SS316L ( C) GD Thread G 1" ½ with cooling fin and flange / SS316L ( C); pressure 40MPa GE Thread G 1" ½ / SS316L with blowing in connection ( C) GP Thread G 1" ½ / SS316L ( C) ZZ Special Additional flange (DN / Material) FA DN50 / PP FB DN50 / PTFE FC DN50 /SS316 GA DN80 / PP GB DN80 / PTFE GC DN80 / SS316 HA DN100 / PP HB DN100 / PTFE HC DN100/ SS316 OO None ZZ Special Seal / Process temperature 2 Viton / C 3 Kalrez / C 4 Graphite / C Electronic preamplifier A None B 4 20mA HART (2-wire); 24Vdc - compulsory for ATEX version C 4 20mA HART (4-wire); 24Vdc D 4 20mA HART (4-wire); 230Vac Housing / Housing protection / Antenna protection D Aluminum 2 chambers (for 4-wire versions) / IP67 / IP68 G SS316L / IP67 / IP68 - compulsory for ATEX version U Aluminum with transparent cap / IP67 / IP68 Z Special Cable entry M M20x1,5 Keyboard/display programming module VL602 A Yes X No

12 RPL57 Continuous level measurement without contact for liquids, pastes and slurries Range 20 m Process pressure 5 bar 2 /4 wires technology Pulse Radar at 26 GHz (K-band) ATEX RPL57 is a pulse radar level transmitter for continuous level measurement of aggressive liquids or processes that require sanitizing. Suitable for use in storage and process tanks. The RPL57 encapsulated antenna protects the sensor from dirt and ensures maintenance-free operation and the front-fl ush installation allows a good cleaning of the exposed surface to the process, even in applications with sanitization. TECHNICAL FEATURES Frequency K group (26GHz) Housing / Antenna material aluminum / SS316L; PTFE Mechanical installation fl ange DN 50; 80; 100 IP rating IP67/IP68 (Sensor) Electrical connection Terminals Working temperature C Pressure -1 a 5 bar Power supply 24Vdc; 230Vac Certification ATEX Analog output 4 20mA Digital communication HART Measure range 20 mt Accuracy ±3mm Risolution 1mm. Calibraton 4 buttons or via HART Warm up 5 minuts Display Plug-in display/keyboard 4 buttons matrix LCD 38 - misura level measure di livello

13 LEVEL RPL57 Radar level transmitter Micro-waves pulse 26GHz group K For highly corrosive liquid storage or process applications Max distance: 20m Accuracy: ±3mm Temperature: C Process pressure: -1 5bar Version I ATEX II 1 G/D Ex ia IIC T6...3 Ga / Ex ia IIIC T76 C...T146 C Da - only with G housing and B electronic P Standard Process connection / Material B Flange DN50 PN40 / SS316 protected in PTFE C Flange DN80 PN40 / SS316 protected in PTFE D Flange DN100 PN16 / SS316 protected in PTFE Z Special Electronic preamplifier A None B 4 20mA HART (2-wire); 24Vdc - compulsory for ATEX version C 4 20mA HART (4-wire); 24Vdc D 4 20mA HART (4-wire); 230Vac Housing / Housing protection / Antenna protection D Aluminum 2 chambers (for 4-wire versions) / IP67 / IP68 G SS316L / IP67 / IP68 - compulsory for ATEX version U Aluminum with transparent cap / IP67 / IP68 Z Special Cable entry M M20x1,5 Keyboard/display programming module VL602 A Yes X No

14 RPL58 Continuous level measurement without contact for solids and powders Range 70 m Process pressure 40 bar 2 /4 wires technology Pulse Radar at 26 GHz (K-band) ATEX RPL58 is a radar sensor for bulk solids continuous measurement. Suitable for application in silos and storage in large sheds, also in hard working conditions. Suitable for level measurement in tanks with 1 ½ G threaded or fl anged connection.the different antenna models and the wide temperature and pressure range make the RPL58 radar sensor the optimal solution for nearly all kinds of application. TECHNICAL FEATURES Frequency K group (26GHz) Housing / Antenna material aluminum / SS316L; PTFE Mechanical installation threaded G1 ½ ; fl ange DN 50; 80; 100; 150; 200; 250 IP rating IP67/IP68 (Sensor) Electrical connection Terminals Working temperature C / C Pressure -1 a 40 bar Power supply 24Vdc; 230Vac Certification ATEX Analog output 4 20mA Digital communication HART Measure range 70 mt Accuracy ±15mm Risolution 1mm. Calibraton 4 buttons or via HART Warm up 5 minuts Display Plug-in display/keyboard 4 buttons matrix LCD 40 - misura level measure di livello

15 LEVEL RPL58 Radar level transmitter Micro-waves pulse 26GHz group K For bulk solids and powders storage or process applications Max distance: 70m Accuracy: ±15mm Process pressure: -1 40bar Version I ATEX II 1 G/D Ex ia IIC T6...3 Ga / Ex ia IIIC T76 C...T146 C Da - only with G housing and B electronic P Standard Antenna shape / Material B Horn antenna Ø48mm / SS316L C Horn antenna Ø78mm / SS316L H Horn antenna Ø98mm / SS316L J Horn antenna Ø123mm / SST316L M Horn antenna Ø98mm / SST316L with PTFE cap P Horn antenna Ø123mm / SST316L with PTFE cap Q Parabolic horn Ø198mm / SST316L R Parabolic horn Ø246mm / SST316L Process connection / Material GC Thread G 1" ½ with cooling fin / SS316L ( C) GE Thread G 1" ½ / SS316L with blowing in connection ( C) GP Thread G 1" ½ / SS316L ( C) ZZ Special Additional flange (DN / Material) FA DN50 / PP FB DN50 / PTFE FC DN50 / SS316 GA DN80 / PP GB DN80 / PTFE GC DN80 / SS316 HA DN100 / PP HB DN100 / PTFE HC DN100 / SS316 HE Aiming device DN100 / SS316 JA DN150 / PP JB DN150 / PTFE JC DN150 / SS316 JE Aiming device DN150 / SS316 KA DN200 / PP KB DN200 / PTFE KC DN200 / SS316 KE Aiming device DN200 / SS316 LA DN250 / PP LB DN250 / PTFE LC DN250 / SS316 LE Aiming device DN250 / SS316 OO None ZZ Special

16 Seal / Process temperature 2 Viton / C 3 Kalrez / C Electronic preamplifier A None B 4 20mA HART (2-wire); 24Vdc - compulsory for ATEX version C 4 20mA HART (4wire); 24Vdc D 4 20mA HART (4-wire); 230Vac Housing / Housing protection / Antenna protection D Aluminum 2 chambers (for 4-wire versions) / IP67 / IP68 G SS316L / IP67 / IP68 - compulsory for ATEX version U Aluminum with transparent cap / IP67 / IP68 Z Special Cable entry M M20x1, misura level measure di livello

17 RPL59 Continuous level measurement without contact for solids and powder Range 15 m Process pressure 40 bar 2 /4 wires technology Pulse Radar at 26 GHz (K-band) ATEX RPL59 is a radar sensor for bulk solids materials continuous measurement. Suitable for application in silos, also in hard working conditions. Suitable for level measurement in tanks with 1 ½ G threaded or fl anged connection. The different antenna models and the wide temperature and pressure range make the RPL59 radar sensor the optimal solution for nearly all kinds of application. TECHNICAL FEATURES Frequency K group (26GHz) Housing / Antenna material aluminum / SS316L; PTFE Mechanical installation threaded G1 ½ ; fl ange DN 50; 80; 100; 150; 200; 250 IP rating IP67/IP68 (Sensor) Electrical connection Terminals Working temperature C / C Pressure -1 a 40 bar Power supply 24Vdc; 230Vac Certification ATEX Analog output 4 20mA Digital communication HART Measure range 15 mt Accuracy ±10mm Risolution 1mm. Calibraton 4 buttons or via HART Warm up 5 minuts Display Plug-in display/keyboard 4 buttons matrix LCD 44 - misura level measure di livello

18 LEVEL RPL59 Radar level transmitter Micro-waves pulse 26GHz group K For bulk solids and powders storage or process applications Max distance: 35m Accuracy: ±10mm Process pressure: -1 40bar Version I ATEX II 1 G/D Ex ia IIC T6...3 Ga / Ex ia IIIC T76 C...T146 C Da - only with G housing and B electronic P Standard Antenna shape / Material B Horn antenna Ø48mm / SS316L C Horn antenna Ø78mm / SS316L H Horn antenna Ø98mm / SS316L J Horn antenna Ø123mm / SST316L M Horn antenna Ø98mm / SST316L with PTFE cap P Horn antenna Ø123mm / SST316L with PTFE cap Q Parabolic horn Ø198mm / SST316L R Parabolic horn Ø246mm / SST316L Z Special Process connection / Material GC Thread G 1" ½ with cooling fin / SS316L ( C) GE Thread G 1" ½ / SS316L with blowing in connection ( C) GP Thread G 1" ½ / SS316L ( C) ZZ Special Additional flange (DN / Material) FA DN50 / PP FB DN50 / PTFE FC DN50 / SS316 GA DN80 / PP GB DN80 / PTFE GC DN80 / SS316 HA DN100 / PP HB DN100 / PTFE HC DN100 / SS316 HE Aiming device DN100 / SS316 JA DN150 / PP JB DN150 / PTFE JC DN150 / SS316 JE Aiming device DN150 / SS316 KA DN200 / PP KB DN200 / PTFE KC DN200 / SS316 KE Aiming device DN200 / SS316 LA DN250 / PP LB DN250 / PTFE LC DN250 / SS316 LE Aiming device DN250 / SS316 OO None ZZ Special

19 Seal / Process temperature 2 Viton / C 3 Kalrez / C Electronic preamplifier A None B 4 20mA HART (2-wire); 24Vdc - compulsory for ATEX version C 4 20mA HART (4wire); 24Vdc D 4 20mA HART (4-wire); 230Vac Housing / Housing protection / Antenna protection D Aluminum 2 chambers (for 4-wire versions) / IP67 / IP68 G SS316L / IP67 / IP68 - compulsory for ATEX version U Aluminum with transparent cap / IP67 / IP68 Z Special 46 - misura level measure di livello

20 RPL61 Continuous level measurement without contact for liquid Range 30/70 m Process pressure atmospheric 2 wires technology Pulse Radar at 26 GHz (K-band) ATEX Blind distance 30 cm RPL61 is a radar sensor for liquids continuous measurement and is confi gured via its remote push button dispaly module. Intended for industrial wastewater, municipal storm water, sewer lift station, reservoir and river. The sensor is designed for bracket mount installation suspended above the liquid level. TECHNICAL FEATURES Frequency K group (26GHz) Housing / Antenna material PBT / PA66 Mechanical installation bracket; G1 IP rating IP67/IP68 (Sensor) Electrical connection Terminals Working temperature C Pressure atmospheric Power supply 24Vdc Certification ATEX Analog output 4 20mA Digital communication HART Measure range 70 mt Accuracy ±1mm Risolution 1mm. Calibraton 4 buttons or via HART Warm up 5 minuts Display Plug-in display/keyboard 4 buttons matrix LCD 48 - misura level measure di livello

21 SENSOR 130mm 94mm LEVEL 1/2" NPT 30mm 1/2" NPT 156mm 280mm 10mm 39mm 1 GAS 31mm 77mm 19mm 81mm 40mm 94mm 12.34mm BK OK 75mm 94mm 19mm 23mm RPL61 Radar level transmitter 124mm Micro-waves pulse 26GHz group K For liquid applications / environmental protection Accuracy: ±3mm Process temperature: C Version E Extended range (70m) I ATEX II 1 G/D Ex ia IIC T6...3 Ga / Ex ia IIIC T76 C...T146 C Da (30m) - only with B electronic P Standard (30m) Antenna shape / Material / Protection P Horm antenna Ø 98mm / Polyammide (PA66) / IP68 Process connection / Material GD Bracket / Stainless steel GP Thread G 1" / PP Electronic preamplifier A None B 4 20mA - 2-wire - HART - 24Vdc R MODBUS RTU Vdc Remote display housing / Protection A PBT / IP66 Remote display VL602 A Yes X No Accessories A Sun shield N None Cable A Standard - 2-wire 10 m max 20m C Specific for MODBUS version - 7m N None 1/2" NPT Adapter

22 GUIDED MICROWAVES A short electromagnetic pulse is sent along a rope and is refl ected back once it reaches its end. If the rope is immersed into the product to be measured, in the point of contact air/product an echo is generated by this discontinuity. The echo comes back to the same rope and is detected as a surface of the product. A method of time elongation, allows the assessment of the time of fl ight which, by its nature, is particularly short, to be able to calculate with accurancy the distance and hence the level of the product to be measured. These are particularly suitable for use with powders, granules, bulk solids such as plastic chips in high and narrow silos, as well as in the food industry because these instruments do not require new calibrations when changing the type of product. Application Type of probe RWL51 liquids / solids rope / rod RWL52 liquids / solids rod Process temperature Process pressure Probe length C C bar bar 3 m (rod) / 30 m (rope) 3 m Probe material SS 316 L / AISI 304 SS 316 L Process connection G 1½ / G 2 fl ange DN Connection material SS 316 L SS 316 L Accuracy Power supply ± 10 mm ± 10 mm 24 Vdc / 230 Vac 24 Vdc / 230 Vac Protection IP67 IP67 Output signal 2/4 wire 4 20 ma Hart 2/4 wire 4 20 ma Hart 50 - misura level measure di livello

23 LEVEL They are also suitable for materials for construction, sand, gravel, etc... The calibrations are possible even in the absence of product. The instrument generates the high frequency pulses through a probe. The pulses are refl ected by the product surface, detected by the internal receiver and converted by microprocessor into level data. The measurement technique, coupled with the EchoDiscovery management system, and the versatility of the RWL series allows the units to be used in severe process conditions with a variety high temperature, high pressure and low dielectric constant. They can be used with materials such as cement, sands and similar products. Application Type of probe RWL53 liquids coaxial RWL54 liquids / solids rope / rod Process temperature Process pressure Probe length C C bar bar 3 m 3 m (rod) / 30 m (rope) Probe material SS 316 L S 316 L Process connection G 1½ / G 2 G 1½ / G 2 Connection material SS 316 L SS 316 L Accuracy Power supply ± 10 mm ± 10 mm 24 Vdc / 230 Vac 24 Vdc / 230 Vac Protection IP67 IP67 Output signal 2/4 wire 4 20 ma Hart 2/4 wire 4 20 ma Hart

24 RWL51 Contact level measurements for liquids and solids Max rod length 3 m ; rope 30 m Process pressure 40 bar 2/4 wires technology Pulse microwave TDR Display of alphanumeric level measurement and of the echo signal curve RWL51 is a guided micro-wave sensor for liquids and bulk solids materials continuous measurement. Insensitive to environmental infl uences like dust and steam, RWL51 provides accurate and repetitive measurement values. RWL51 constitutes the solution for multiple level measurements. Suitable for application in silos or tanks, also in hard working conditions. Suitable for level measurement in tanks with 1 ½ G or 2 g threaded. RWL51 is available with rope or rigid rod antenna. TECHNICAL FEATURES Housing / Antenna material aluminum / SS316L Mechanical installation threaded G 1½ ; G 2 IP rating IP67 Electrical connection Terminals Working temperature C / C Pressure bar Power supply 24Vdc; 230Vac Analog output 4 20mA Digital communication HART Measure range rod 3 m; rope 30 m; semi-fl exible pipe 30 m Accuracy ±10mm Risolution 1mm. Calibraton 4 buttons or via HART Warm up 5 minuts Display Plug-in display/keyboard 4 buttons matrix LCD 52 - misura level measure di livello

25 LEVEL RWL51 Version P Standard Guided microwave radar level transmitter Microwaves pulse TDR For liquids and bulk solids measurement Max. length: rod 3m, rope 30m (Ø4mm or Ø6mm according to the application) Accuracy: ±10mm Process pressure: bar Antenna shape / Material / Sealing A Rope Ø4mm (up to 5m) or Rope Ø 6mm (over 5m) / SS316L / PTFE B Rod Ø10mm / SS316L / PTFE C Semi-flexible pipe Ø8mm / SS304 / PTFE Process connection / Material GP Thread G1 ½" / SS316L KP Thread G2" A / SS316L ZZ Special Seal / Process temperature A Viton / C B Kalrez / C Electronic preamplifier B 4 20mA HART (2-wire); 24Vdc C 4 20mA HART (4wire); 24Vdc D 4 20mA HART (4wire); 230Vac Housing / Protection D Aluminum 2 chambers (for 4-wire versions) / IP67 G SS316L / IP67 U Aluminum with transparent cap / IP67 Z Special Cable entry M M20x1,5 Keyboard/display programming module VL602 A Yes X No L= length, price each 100mm A Rope Ø4/6mm / SS316L (max 30m) B Rod Ø10mm / SS316L (max 3m) C Semi-flexible pipe Ø8mm / SS304 (max 30m)

26 RWL52 Contact level measurements for liquids and solids Max length 3 m Process pressure 16 bar 2/4 wires technology Pulse microwave TDR Display of alphanumeric level measurement and the curve of the echo signal RWL52 constitutes the solution for multiple level measurements. Suitable for application in silos or tanks, also in hard working conditions. Suitable for level measurement in tanks with fl anged connection. RWL52 is available with rigid rod antenna. TECHNICAL FEATURES Housing / Antenna material aluminum / SS316L Mechanical installation Flange DN50; 80; 100; 150 IP rating IP67 Electrical connection Terminals Working temperature C Pressure bar Power supply 24Vdc; 230Vac Analog output 4 20mA Digital communication HART Measure range 3m Accuracy ±10mm Risolution 1mm. Calibraton 4 buttons or via HART Warm up 5 minuts Display Plug-in display/keyboard 4 buttons matrix LCD 54 - misura level measure di livello

27 LEVEL RWL52 Version P Standard Guided microwave radar level transmitter Microwaves pulse TDR For liquids and bulk solids measurement Max. length: 3m Accuracy: ±10mm Process pressure: -1 16bar Antenna shape / Material / Sealing A Rod Ø10mm / SS316L / PTFE Process connection / Material FA Flange DN50 PN16 / SS316L (GB/T ) FB Flange DN80 PN16 / SS316L (GB/T ) FC Flange DN100 PN16 / SS316L (GB/T ) FD Flange DN150 PN16 / SS316L (GB/T ) ZZ Special Seal / Process temperature A Viton / C Electronic preamplifier B 4 20mA HART (2-wire); 24Vdc C 4 20mA HART (4wire); 24Vdc D 4 20mA HART (4-wire); 230Vac Housing / Protection D Aluminum with 2 chambers (for 4-wire versions) / IP67 G SS316 / IP67 U Aluminum with transparent cap / IP67 Z Special Cable entry M M20x1,5 Keyboard/display programming module VL602 A Yes X No L= length, price each 100mm A Rod Ø10mm / SS316L (max 3m)

28 RWL53 Contact level measurements for liquids Max length 3 m Process pressure 40 bar 2/4 wires technology Pulse microwave TDR Display of alphanumeric level measurement and the curve of the echo signal RWL53 constitutes the solution for multiple level measurements. Suitable for application in tanks, also in hard working conditions. Suitable for level measurement in tanks with 1 ½ G or 2 g threaded. RWL53 is available with coaxial antenna TECHNICAL FEATURES Housing / Antenna material aluminum / SS316L Mechanical installation threaded G 1½ A o G 2 IP rating IP67 Electrical connection Terminals Working temperature C ; C Pressure bar Power supply 24Vdc; 230Vac Analog output 4 20mA Digital communication HART Measure range coaxial antenna Ø28 max 3m Accuracy ±10mm Risolution 1mm. Calibraton 4 buttons or via HART Warm up 5 minuts Display Plug-in display/keyboard 4 buttons matrix LCD 56 - misura level measure di livello

29 LEVEL RWL53 Version P Standard Guided microwave radar level transmitter Microwaves pulse TDR For small dielectric constant liquids (oils, distilled water, others) Max. length: 3m Accuracy: ±10mm Process pressure: -1 40bar Antenna shape / Material / Sealing A Coaxial Ø28mm / SS316L / PTFE Process connection / Material GP Thread G1" ½ / SS316L KP Thread G2" A / SS316L ZZ Special Seal / Process temperature A Viton / C B Kalrez / C Electronic preamplifier B 4 20mA HART (2-wire); 24Vdc C 4 20mA HART (4wire); 24Vdc D 4 20mA HART (4-wire); 230Vac Housing / Protection D Aluminum with 2 chambers (for 4-wire versions) / IP67 G SS316L / IP67 U Aluminum with transparent cap / IP67 Z Special Cable entry M M20x1,5 Keyboard/display programming module VL602 A Yes X No L= length, price each 100mm A Coaxial Ø28mm / SS316L (max 3m)

30 RWL54 Contact level measurements for liquids and solids Max rod length 3 m ; rope 30 m Process pressure 40 bar 2/4 wires technology Pulse microwave TDR Display of alphanumeric level measurement and the curve of the echo signal RWL54 is a guided micro-wave sensor for liquids and bulk solids materials continuous measurement. Insensitive to environmental infl uences like dust and steam, RWL54 provides accurate and repetitive measurement values. RWL54 constitutes the solution for multiple level measurements. Suitable for application in silos or tanks, also in hard working conditions with high temperatures (200 C max.). Suitable for level measurement in tanks with 1 ½ G or 2 g threaded. RWL54 is available with rope or rigid rod antenna. TECHNICAL FEATURES Housing / Antenna material aluminum / SS316L Mechanical installation threaded G 1½ A o G 2 IP rating IP67 Electrical connection Terminals Working temperature C ; C Pressure bar Power supply 24Vdc; 230Vac Analog output 4 20mA Digital communication HART Measure range Rod Ø10 max 3m; Rope Ø4mm max 5m; Rope Ø6mm max. 30m Accuracy ±10mm Risolution 1mm. Calibraton 4 buttons or via HART Warm up 5 minuts Display Plug-in display/keyboard 4 buttons matrix LCD 58 - misura level measure di livello

31 LEVEL RWL54 Version P Standard Guided microwave radar level transmitter Microwaves pulse TDR For liquids with high process temperature/pressure Max. length: 3m rod - 30m rope Accuracy: ±10mm Process pressure: -1 40bar Antenna shape / Material / Sealing A Rope Ø4mm (up to 5m) or Rope Ø 6mm (over 5m) / SS316L / PTFE B Rod Ø10mm / SS316L / PTFE Process connection / Material GP Thread G1" ½ with cooling fin / SS316L KP Thread G2" with cooling fin / SS316L ZZ Special Seal / Process temperature A Viton / C B Kalrez / C Electronic preamplifier B 4 20mA HART (2-wire); 24Vdc C 4 20mA HART (4wire); 24Vdc D 4 20mA HART (4-wire); 230Vac Housing / Protection D Aluminum with 2 chambers (for 4-wire versions) / IP67 G SS316L / IP67 U Aluminum with transparent cap / IP67 Z Special Cable entry M M20x1,5 Keyboard/display programming module VL602 A Yes X No L= Electrode length, price each 100mm A Rope Ø4/6mm / SS316L (max 30m) B Rod Ø10mm / SS316L (max 3m) C Rod Ø10mm / SS304 (max 3m)

32 SGM-LEKTRA S.r.l. Via Papa Giovanni XXIII, Rodano (MI) - ITALY tel: fax: info@sgm-lektra.com web: Rev.0 sgm-lektra.com

SGM LEKTRA LEVEL Measurement Control SGM LEKTRA Capacitive Ultrasonic Radiated microwave Guided Microwave Hydrostatic head Vibration Resistive

SGM LEKTRA LEVEL Measurement Control SGM LEKTRA Capacitive Ultrasonic Radiated microwave Guided Microwave Hydrostatic head Vibration Resistive level measurement LEVEL SGM LEKTRA produces level measurement instruments for industrial applications and for environmental monitoring. These instruments are divided into two groups: Measurement - Numeric

More information

SGM LEKTRA LEVEL Measurement Control SGM LEKTRA Capacitive Ultrasonic Radiated microwave Guided Microwave Hydrostatic head Vibration Resistive

SGM LEKTRA LEVEL Measurement Control SGM LEKTRA Capacitive Ultrasonic Radiated microwave Guided Microwave Hydrostatic head Vibration Resistive level measurement LEVEL SGM LEKTRA produces level measurement instruments for industrial applications and for environmental monitoring. These instruments are divided into two groups: Measurement - Numeric

More information

The Radar Level Meters can be installed both in metallic or non metallic tanks; their use is not harmful to humans or environment.

The Radar Level Meters can be installed both in metallic or non metallic tanks; their use is not harmful to humans or environment. 1 EIP COMPACT WAVE 26 GHZ CW Series PULSE RADAR LEVEL INSTRUMENTS (26 GHz) DESCRIPTION The Radar Level Meters of EIP COMPACT WAVE 6.3 GHz series are excellent devices for no contact level measurement.

More information

Level measurement Radar

Level measurement Radar Level measurement Radar Overview 6 VEGAPULS series 60 8 Dimensions 20 AL-EN - 5 Level measurement Radar VEGAPULS: Non-contact measurement of liquids and solids under arduous process conditions Measuring

More information

DREXELBROOK. IMPULSE Series. Guided Wave Radar (TDR) Easy to install, Easy to use. Dependable performance. The New Impulse Guided Wave Radar

DREXELBROOK. IMPULSE Series. Guided Wave Radar (TDR) Easy to install, Easy to use. Dependable performance. The New Impulse Guided Wave Radar DREXELBROOK A Leader In Level Measurement Solutions IMPULSE Series Guided Wave Radar (TDR) and Volumetric for Total Level Measurements TDR Level Measurement Easy to install, Easy to use TDR Level Measurement

More information

DREXELBROOK. IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements. Easy to install, Easy to use. Dependable performance

DREXELBROOK. IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements. Easy to install, Easy to use. Dependable performance DREXELBROOK A Leader In Level Measurement Solutions IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements TDR Level Measurement Easy to install, Easy to use TDR Level Measurement

More information

Level transmitters Series LTDR TDR guided radar level transmitter for liquids and solids

Level transmitters Series LTDR TDR guided radar level transmitter for liquids and solids Level transmitters Series LTDR TDR guided radar level transmitter for liquids and solids Level measurement independent of changing process conditions (density, conductivity, temperature, pressure, ) Innovative

More information

TEK-F LEX 4100A. Guided Wave Radar Level Transmitter. LEVEL. Technology Solutions

TEK-F LEX 4100A. Guided Wave Radar Level Transmitter.   LEVEL. Technology Solutions Technology Solutions TEK-F LEX 4100A Guided Wave Radar Level Transmitter LEVEL www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Featuring TDR (Time Domain

More information

6GHz Intelligent Radar Level Meter Product Manual. Model:KRD520 SERIES

6GHz Intelligent Radar Level Meter Product Manual. Model:KRD520 SERIES 6GHz Intelligent Radar Level Meter Product Manual Model:KRD520 SERIES Directory 1 Product Overview...1 2 Product Introduction...2 3 The Installation Requirements...4 4 The Electrical Connection...6 5 Instrument

More information

Level Measurement Continuous level measurement Radar transmitters

Level Measurement Continuous level measurement Radar transmitters Overview Configuration Mounting on a nozzle is a 2-wire 25 GHz pulse radar level transmitter for continuous monitoring of solids and liquids in storage vessels including extreme levels of dust and high

More information

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview Overview Application It provides excellent results on low dielectric media. is available for standard applications and for applications that require explosion proof protection. features robust enclosure,

More information

REFLEX RADAR INDICATOR

REFLEX RADAR INDICATOR REFLEX RADAR INDICATOR Why Radar Technology for Level Measurement? INSENSITIVE TO CHANGES IN Dielectric Pressure Vacuum Humidity Dust Viscosity Foam Temperature THE ADVANTAGES ARE Measuring ranges up to

More information

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR300. 5/180 Siemens FI Overview

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR300. 5/180 Siemens FI Overview Overview is a 4-wire, 6 GHz pulse radar level transmitter for continuous and process vessels including high temperature and pressure, to a range of 20 m (66 ft). Benefits Auto False-Echo Suppression Infrared

More information

RADAR TRANSMITTERS BLISSFLEX 1100 SELECTION GUIDE. The characters of the order code have been described below

RADAR TRANSMITTERS BLISSFLEX 1100 SELECTION GUIDE. The characters of the order code have been described below BLISSFLEX 1100 The characters of the order code have been described below BA25 4 BLISSFLEX 1100 C 2-wire loop-powered 4...20 ma Guided Radar (TDR) level meter: -50...+100 C and -1...16 barg / -58...212

More information

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview Overview Application It provides excellent results on low dielectric media. is available for standard applications and for applications that require explosion proof protection. features robust enclosure,

More information

LEVEL Transmitters. SAP-300 display. Mono cable / Mono rod Mono segmented rod. Twin cable Twin rod Coaxial Pipe

LEVEL Transmitters. SAP-300 display. Mono cable / Mono rod Mono segmented rod. Twin cable Twin rod Coaxial Pipe Guided microwave level transmitters GENERAL DESCRITION The Guided Wave Radar level transmitter is designed for continuous level measuring of conductive or non-conductive liquids, pulps and solids. level

More information

OEM radar transmitter, for aggressive media level measurement

OEM radar transmitter, for aggressive media level measurement OEM radar transmitter, for aggressive media level measurement C ompact for level measurement up to 20 m 4... 20 ma/hart - 2 wires Adjustable with P C ATEX approvals Type 8136 can be combined with... Type

More information

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA Mobrey Ultrasonic Product Data Sheet February 215 IP245, Rev EA MSP422, MSP4RH, and MSP9GH Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for

More information

Level Measurement With REFLEX RADAR

Level Measurement With REFLEX RADAR Reflex Radar & TDR HYC-RR02 Elect. Iss. 02 Level Measurement With REFLEX RADAR Why Radar Technology for Level Measurement? INSENSITIVE TO CHANGES IN Dielectric Pressure Vacuum Humidity Dust Viscosity Foam

More information

FOSTEN AUTOMATION SÉRIE F500-RD

FOSTEN AUTOMATION SÉRIE F500-RD FOSTEN AUTOMATION SÉRIE Guided Wave Radar Level Transmitter Guided wave radar level transmitter. Low maintenance, auto calibrated references. Easy installation, directly in tanks or auxiliary vessels.

More information

Level Measurement With REFLEX RADAR

Level Measurement With REFLEX RADAR Reflex Radar & TDR HYC-RR03 Elect. Iss. 03 Level Measurement With REFLEX RADAR Why Radar Technology for Level Measurement? INSENSITIVE TO CHANGES IN Dielectric Pressure Vacuum Humidity Dust Viscosity Foam

More information

analytical bulk flow distance flow LEVEL pressure temperature industrial communication

analytical bulk flow distance flow LEVEL pressure temperature industrial communication analytical bulk flow distance flow LEVEL pressure temperature industrial communication RD800 LONG RANGE 2-WIRE RADAR LEVEL TRANSMITTER SERIES The extremely narrow microwave pulse emitted by the antenna

More information

DREXELBROOK DREXELBROOK. Impulse. Series IMPULSE. IMPULSE Series. Guided Wave Radar (TDR) for Total Level and Volumetric Measurements DATA SHEET

DREXELBROOK DREXELBROOK. Impulse. Series IMPULSE. IMPULSE Series. Guided Wave Radar (TDR) for Total Level and Volumetric Measurements DATA SHEET t DREXELBROOK DATA SHEET DREXELBROOK A Leader In Level Measurement Solutions IMPULSE Series IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements TDR Level Measurement Easy

More information

Main features. Operation. LEVEL Transmitters

Main features. Operation. LEVEL Transmitters Non-contact microwave level transmitters pilotr GNRAL DSCRIPTION The 25 GHz (-band) Pulse Radars are regarded as the most progressive non-contact level transmitters of the industrial process automation

More information

Ultrasonic Liquid Level Transmitters

Ultrasonic Liquid Level Transmitters Product Data Sheet Ultrasonic Liquid Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for on-site programming Continuous measurement of level

More information

Xperience The Future in Level Measurements

Xperience The Future in Level Measurements Products Solutions Services Xperience The Future in Level Measurements The right answer for any application Slide 2 Xperience The Future 113GHz + Wavelength. Micropilot FMR10/20 Liquipoint FTW33 Simple

More information

ABB MEASUREMENT & ANALYTICS. LLT100, LM80 and LM200 Lasers for level now everything is possible

ABB MEASUREMENT & ANALYTICS. LLT100, LM80 and LM200 Lasers for level now everything is possible ABB MEASUREMENT & ANALYTICS LLT100, LM80 and LM200 Lasers for level now everything is possible 2 L LT 1 0 0, L M 8 0 A N D L M 2 0 0 L A S E R S F O R L E V E L N O W E V E R Y T H I N G I S P O S S I

More information

TGF2200 Micro Pulse Level Meter

TGF2200 Micro Pulse Level Meter Guided Radar with 2-wire system TGF2200 Micro Pulse Level Meter OUTLINE The TGF2200 series is a unique 2-wire continuous level-measuring instrument using TDR technology. The simple and compact design suitable

More information

SITRANS L Level instruments

SITRANS L Level instruments SITRANS L Level instruments /2 Point level measurement /6 Capacitance switches /9 Pointek CLS100 /1 Pointek CLS200 /31 Pointek CLS300 /47 Pointek CLS00 /62 Pointek Specials Electro-mechanical switches

More information

TGR wire System Guided Radar Gauge. MICRO-PULSE level meter GENERAL FEATURES OPERATION PRINCIPLE

TGR wire System Guided Radar Gauge. MICRO-PULSE level meter GENERAL FEATURES OPERATION PRINCIPLE 2-wire System Guided Radar Gauge TGR3000 MICRO-PULSE level meter GENERAL TGR3000 series is the 2-wire system Guided Radar Gauge which can continuously measure the level using micro-pulse. The micropulse

More information

analytical bulk flow distance flow LEVEL pressure temperature industrial communication

analytical bulk flow distance flow LEVEL pressure temperature industrial communication analytical bulk flow distance flow LEVEL pressure temperature industrial communication RD900 2-Wire Radar Level Transmitter for Solids Level Measurement The extremely narrow microwave pulse emitted by

More information

PiloTREK SZINTTÁVADÓK LEVEL TRANSMITTERS PU L S E BU RS T R A DA R LE V E L TR A NSMIT TERS K- BA N D R A DA R FO R LI Q U I DS

PiloTREK SZINTTÁVADÓK LEVEL TRANSMITTERS PU L S E BU RS T R A DA R LE V E L TR A NSMIT TERS K- BA N D R A DA R FO R LI Q U I DS 3 YEARS WARRANTY PiloTREK SZINTTÁVADÓK LEVEL TRANSMITTERS PU L S E BU RS T R A DA R LE V E L TR A NSMIT TERS K- BA N D R A DA R FO R LI Q U I DS MAIN FEATURES 2-wire K-band Pulse Burst Radar 25 GHz frequency

More information

Level gauges Series LT Level indicator, switch and transmitter for liquids

Level gauges Series LT Level indicator, switch and transmitter for liquids Level gauges Series LT Level indicator, switch and transmitter for liquids Simple construction Resistant under extreme temperature and pressure conditions No risk of leakage Excellent chemical resistance

More information

NCR-80. BinMaster Price Book binmaster.com Subject to change without notice 1

NCR-80. BinMaster Price Book binmaster.com Subject to change without notice 1 NCR-80 inmaster Price ook 01-2019 binmaster.com Subject to change without notice 1 NCR-80 NCR-80 Non-contact radar continuously measures the level of powders, granules, solids, or liquids in a vessel.

More information

FOR LIQUIDS AND SOLIDS

FOR LIQUIDS AND SOLIDS FOR LIQUIDS AND SOLIDS LEVEL TRANSMITTERS GUIDED MICROWAVE LEVEL TRANSMITTERS O U R P R O F E S S I O N MicroTREK LEVEL TRANSMITTERS FOR LIQUIDS AND SOLIDS MAIN FEATURES Measuring range up to 24 m (80

More information

MicroTREK GUIDED MICROWAVE LEVEL TRANSMITTERS

MicroTREK GUIDED MICROWAVE LEVEL TRANSMITTERS For liquids and solids MicroTREK GUIDED MICROWAVE LEVEL TRANSMITTERS O U R P R O F E S S I O N I S Y O U R L E V E L LEVEL TRANSMITTERS MicroTREK TRANSMITTERS FOR LIQUIDS AND SOLIDS FEATURES Measuring

More information

K-BAND RADAR FOR LIQUIDS

K-BAND RADAR FOR LIQUIDS K-BAND RADAR FOR LIQUIDS LEVEL TRANSMITTERS PULSE BURST RADAR LEVEL TRANSMITTERS O U R P R O F E S S I O N PiloTREK NON-CONTACT MICROWAVE LEVEL TRANSMITTERS FOR LIQUIDS MAIN FEATURES 2-wire K-band Pulse

More information

process measurement solutions Mobrey MSP IP wire 24V loop powered ultrasonic level transmitters

process measurement solutions Mobrey MSP IP wire 24V loop powered ultrasonic level transmitters process measurement solutions Mobrey MSP 2 wire 24V loop powered ultrasonic level transmitters IP2045 MSP Advanced ultrasonics This new family of ultrasonic non-contacting liquid level transmitters is

More information

Technologies, Solutions, and Applications. Guided Wave Radar for Level

Technologies, Solutions, and Applications. Guided Wave Radar for Level Technologies, Solutions, and Applications Guided Wave Radar for Level Contents Leadership in Guided Wave Radar 3 Principles of Operation 4 Models and Versions 5 Guided Wave Radar in the plics System 8

More information

NUS-4. Ultrasonic Level Transmitter. for Liquids and Solids

NUS-4. Ultrasonic Level Transmitter. for Liquids and Solids Ultrasonic Level Transmitter for Liquids and Solids measuring monitoring analyzing 4 Measuring Ranges: Liquids: Up to 25 meters (80 feet) Solids: Up to 10 meters (32 feet) Accuracy: ± 0.2 % of Reading

More information

Georg Fischer Piping Systems Point, Ultrasonic & Radar Level Products

Georg Fischer Piping Systems Point, Ultrasonic & Radar Level Products Georg Fischer Piping Systems Point, Ultrasonic & Radar Level Products Presented to valued clients attending the Technology Summit hosted by: Kendall Group/ J.O.Galloup +GF+ Offering Level Measurement Continuous

More information

Level Measurement Continuous level measurement Radar transmitters SITRANS LR200. Overview. Configuration

Level Measurement Continuous level measurement Radar transmitters SITRANS LR200. Overview. Configuration Overview Configuration Installation Min. 300 mm (1 ft) for every 3 m (10 ft) of vessel wall. is a 2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in process

More information

Level Measurement Continuous level measurement - Radar transmitters

Level Measurement Continuous level measurement - Radar transmitters Overview Configuration Installation Min. 300 mm (1 ft) for every 3 m (10 ft) of vessel wall. is a 2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in process

More information

SITRANS LR 300: High Performance Radar for Level Measurement

SITRANS LR 300: High Performance Radar for Level Measurement SITRANS LR 300: High Performance Radar for Level Measurement Reliable Measurement In Extreme Conditions SITRANS LR 300 delivers high performance level measurement at an affordable price for the chemical,

More information

Target disk flowmeter for liquids and gases

Target disk flowmeter for liquids and gases Target disk flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions Low pressure drop Straight

More information

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases Target disk flowmeters Series DP Metallic flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions

More information

OPTIWAVE 7300 C Supplementary instructions

OPTIWAVE 7300 C Supplementary instructions OPTIWAVE 7300 C Supplementary instructions Radar (FMCW) Level Transmitter for agitated liquids in process applications Supplementary Instructions for ATEX applications KROHNE CONTENTS OPTIWAVE 7300 C General

More information

Condumax W CLS15 and CLS15D

Condumax W CLS15 and CLS15D Technical Information Condumax W CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure

More information

Switching. Radar. Overview 114 VEGAMIP series Mounting adapter 120

Switching. Radar. Overview 114 VEGAMIP series Mounting adapter 120 Switching Radar Overview 114 VEGAMIP series 60 116 Mounting adapter 120 113 VEGAMIP Level detection in bulk solids and liquids Measuring principle The measuring system consists of a microwave emitter and

More information

Condumax CLS21 and CLS21D

Condumax CLS21 and CLS21D Technical Information Condumax CLS21 and CLS21D Conductivity sensors, analog or digital with Memosens technology Cell constant k = 1 cm -1 Application Measurements in media of medium and high conductivities:

More information

Rosemount 3101, 3102, and 3105

Rosemount 3101, 3102, and 3105 Product Data Sheet February 2013 00813-0100-4840, Rev DA Rosemount 3101, 3102, and 3105 Ultrasonic Liquid Level Transmitters Non-contacting measurement with no moving parts Integral LCD and buttons as

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:

More information

SITRANS L Level instruments

SITRANS L Level instruments Overview is a 2-wire, 6 GHz pulse radar level transmitter for continuous and process vessels including high temperature and pressure, to a range of 20 m (66 ft). Benefits Uni-Construction polypropylene

More information

Level Measurement. GDSL Series. Ultrasonic Level Sensor

Level Measurement. GDSL Series. Ultrasonic Level Sensor Level Measurement GDSL Series Ultrasonic Level Sensor Contact Person: (Mr.) Mason. DING +86 153 9807 6422 / +86 158 2936 4223 mason.ding@tosilon.com www.tosilon.com Principle Ultrasonic pulses generated

More information

TMU. Coriolis Mass Flow Meter. for liquids and gas

TMU. Coriolis Mass Flow Meter. for liquids and gas Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TMU S5 OO Measuring range: 0-60 kg/h 0-2200 t/h water OO Accuracy: ± 0.1% of reading ±zero point stability (from liquids up to

More information

PiloTREK SZINTTÁVADÓK. Pulse burst radar level transmitters 5 YEARS WARRANTY

PiloTREK SZINTTÁVADÓK. Pulse burst radar level transmitters 5 YEARS WARRANTY PiloTREK Pulse burst radar level transmitters K-BAND RADAR for liquids SZINTTÁVADÓK Level transmitters 5 YEARS WARRANTY MAIN FEATURES 2-wire K-band Pulse Burst Radar 25 GHz frequency Max. 23 m (75 feet)

More information

Indumax CLS50/CLS50D. Technical Information

Indumax CLS50/CLS50D. Technical Information Technical Information Indumax CLS50/CLS50D Inductive conductivity sensor for standard, hazardous and high-temperature applications, analog or digital with Memosens protocol Application Indumax CLS50/CLS50D

More information

d = c 10/20/2017 Level Measurement Transmitters Applying Level Measurement p C T 273K Ultrasonic The Principle Time of Flight (TOF)

d = c 10/20/2017 Level Measurement Transmitters Applying Level Measurement p C T 273K Ultrasonic The Principle Time of Flight (TOF) Products Solutions Services Level Measurement Transmitters Applying Level Measurement Ultrasonic FDU95 FDU93 FDU92 FDU91 FDU90 Slide 1 Slide 2 The Principle Time of Flight (TOF) Emission of ultrasound

More information

Level Measurement Continuous level measurement Radar transmitters

Level Measurement Continuous level measurement Radar transmitters Overview Benefits Process Intelligence for advanced signal processing and quick and easy adjustment Self-guided quick start wizard for plug and play startup 2 GHz provides superior reflective properties

More information

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0. Technical Information Condumax W CLS9 Conductivity sensors Two-electrode sensors with cell constants k = 0.0 cm or k = 0. cm Application Measurement in pure and ultrapure water: Monitoring ion exchangers

More information

Condumax CLS21 and CLS21D

Condumax CLS21 and CLS21D Technical Information Condumax CLS21 and CLS21D Conductivity sensors, analog or digital with Memosens technology Cell constant k = 1 cm -1 Application Measurements in media of medium and high conductivities:

More information

RPL Radar level transmitter K group

RPL Radar level transmitter K group RPL55-56-58 Radar level transmitter K group 825B112A Features Continuous, non-contact level measurement for solids, liquids, pulps and slurries Measurement not affected by product physical variation, and

More information

prosonic T FMU230, FMU231

prosonic T FMU230, FMU231 Technical Information prosonic T FMU230, FMU231 Ultrasonic Level Measurement Compact transmitters for non-contact level measurement of fluids and coarse bulk materials Application The compact transmitters

More information

TLR wire System Level Radar. MICROWAVE level meter GENERAL FEATURES OPERATION PRINCIPLE

TLR wire System Level Radar. MICROWAVE level meter GENERAL FEATURES OPERATION PRINCIPLE 2-wire System Level Radar TLR3000 MICROWAVE level meter GENERAL The TLR3000 is a non-contact type continuous level meter using microwaves. It detects a level by measuring a reciprocating time of a microwave

More information

Condumax CLS15 and CLS15D

Condumax CLS15 and CLS15D Technical Information Condumax CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure

More information

F78MP Series Radar FEATURES AND BENEFITS

F78MP Series Radar FEATURES AND BENEFITS F78MP Series Radar The F78MP Series air radar sensor provides non-contact, continuous level measurement for bulk materials in bins, tanks and silos. Accurate and reliable in difficult environments, the

More information

Technical Datasheet. Guided Radar (TDR) Level Transmitter for heavy-duty and interface applications

Technical Datasheet. Guided Radar (TDR) Level Transmitter for heavy-duty and interface applications OPTIFLEX 1300 C Technical Datasheet Guided Radar (TDR) Level Transmitter for heavy-duty and interface applications Universal device that can measure level of liquids, pastes, granulates, powders, and liquid

More information

OPTIWAVE 7400 C Technical Datasheet

OPTIWAVE 7400 C Technical Datasheet OPTIWAVE 7400 C Technical Datasheet 24 GHz Radar (FMCW) Level Transmitter for agitated and corrosive liquids Process conditions up to +200 C / +392 F and 100 barg / 1450 psig Quick coupling housing and

More information

DATA SHEET CONTACT KFA SARL PHONE +33 (603) WEB KFA2_DA_V12_en_0913 1/10

DATA SHEET CONTACT KFA SARL PHONE +33 (603) WEB  KFA2_DA_V12_en_0913 1/10 DATA SHEET KFA2 4-wire TDR-Sensor with single rod, wire rope or coaxial probe for continuous level measurement and point level detection in liquids and light solids, with analog and switching output. MEASUREMENT

More information

2-Wire. Level Gauge BM 702

2-Wire. Level Gauge BM 702 KROHNE 09/2001 7.02323.22.00 GR/PRINTO Level Gauge 2-Wire Level-Radar 2-Wire The first and only FMCW Radar Level Gauge with 2-wire technology The non-contact alternative to ageing technologies Maintenance-free

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:

More information

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically

More information

Technical Information Condumax CLS15D/CLS15

Technical Information Condumax CLS15D/CLS15 TI0009C/07/EN/4.4 7268306 Products Solutions Services Technical Information Condumax CLS5D/CLS5 Conductivity sensors, analog or digital with Memosens technology Cell constant k = 0.0 cm or k = 0. cm Application

More information

Sultan Liquid- Acoustic Wave Technology

Sultan Liquid- Acoustic Wave Technology A higher level of performance Data Sheet Sultan Liquid- Acoustic Wave Technology Liquids level and position measurements to 10m (33ft) Principle of Operations The Sultan Liquid series emits a high powered

More information

Manufactured by M-Sens 2 Online-Moisture Meter for Solids. Moisture % Product Information.

Manufactured by M-Sens 2 Online-Moisture Meter for Solids. Moisture % Product Information. EN Manufactured by M-Sens 2 Online-Moisture Meter for Solids Product Information Moisture 13.47 % www.onthelevel.com Using M-Sens 2 is specifically designed for continuous moisture measurement of solids.

More information

Technical Information Condumax CLS21D/CLS21

Technical Information Condumax CLS21D/CLS21 TI00085C/07/EN/14.14 71268310 Products Solutions Services Technical Information Condumax CLS21D/CLS21 Conductivity sensors, analog or digital with Memosens technology Cell constant k = 1.0 cm 1 Application

More information

Technical Information Indumax CLS50D/CLS50

Technical Information Indumax CLS50D/CLS50 TI00182C/07/EN/16.15 71280313 Products Solutions Services Technical Information Indumax CLS50D/CLS50 Inductive conductivity sensor for standard, Ex and high-temperature applications Digital sensor with

More information

Radar Level Measurement micropilot FMR 130 for stilling wells

Radar Level Measurement micropilot FMR 130 for stilling wells Technical Information TI 258F/24/ae Radar Level Measurement micropilot FMR 130 for stilling wells Smart transmitter for non-contact measurement in metallic by-pass pipes and stilling wells Suitable for

More information

Condumax CLS15 and CLS15D

Condumax CLS15 and CLS15D Technical Information Condumax CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to

More information

Rod probe With coaxial tube reference probe

Rod probe With coaxial tube reference probe Capacitive level transmitters GENERAL DESCRIPTION NIVOCAP 2-wire capacitive level transmitters provide an ideal solution for level measurement of conductive or non-conductive liquids. The probe of the

More information

NGR. Guided Wave Radar Level Transmitter

NGR. Guided Wave Radar Level Transmitter Guided Wave Radar Level Transmitter measuring monitoring analyzing NGR For Liquids Operates Independent of Density, Temperature, Pressure, Humidity, and Conductivity Standard Measuring Length: 6. Ft (Longer

More information

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI Overview The is a -wire, 2 GHz FMCW radar level transmitter with extremely high signal-to-noise ratio and advanced signal processing for continuous monitoring of solids up to 100 m (328 ft). It is ideal

More information

Guided Wave Radar Bulk Solids Level Transmitter

Guided Wave Radar Bulk Solids Level Transmitter www.ktekcorp.com Guided Wave Radar Bulk Solids Level Transmitter FEATURES Radar Signal Travels Along the Waveguide Eliminates False Echoes and Minimizes Signal Loss No Moving Parts 2 Wire Loop Powered

More information

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit > A Higher Level of Performance Data Sheet Series 000 Pressure and Level Transmitters For more information, please visit > www.hawkmeasure.com Series 000 000-SAN Cable with separate electronics Description

More information

OPTIWAVE 5400 C Technical Datasheet

OPTIWAVE 5400 C Technical Datasheet OPTIWAVE 5400 C Technical Datasheet 24 GHz Radar (FMCW) Level Transmitter for liquids in basic process applications Market-entry transmitter Proven PP Drop antenna design insensitive to condensation KROHNE

More information

LST400 Ultrasonic level / open channel flow transmitter

LST400 Ultrasonic level / open channel flow transmitter Data sheet DS/LST400 EN Rev.C LST400 Ultrasonic level / open channel flow transmitter Measurement made easy Reduced installation cost Easy access terminations Integrated echo display makes for easy troubleshooting

More information

FLOAT LEVEL SENSOR TFC. Applications. Reference. Features

FLOAT LEVEL SENSOR TFC. Applications. Reference. Features FLOAT LEVEL SENSOR The label Trafag Industrial Components extends the Trafag brand name to instruments manufactured by qualified partner companies. Trafag Industrial Components complement the genuine Trafag

More information

Digital conductivity transmitter

Digital conductivity transmitter Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due

More information

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER 1 www. otech.com.sg EFS801 - CFT181/RFT201 ELECTROMAGNETIC FLOWMETER Accurate, Reliable and Stable Flow Measurement. Measuring Principle The measuring

More information

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement Technical Data Sheet Non-Contact, Multiple-Point Measurement The 3DLevelScanner is a noncontact, dust-penetrating bin measurement device that detects irregular surfaces in powder or solid materials and

More information

LST100 Ultrasonic level transmitter for upstream oil and gas

LST100 Ultrasonic level transmitter for upstream oil and gas Data sheet DS/LST100-EN LST100 Ultrasonic level transmitter for upstream oil and gas Accurately track and measure the most expensive consumable on your site chemicals. Measurement made easy Features Keep

More information

WP-L Hydrostatic head level transmitter

WP-L Hydrostatic head level transmitter WP-L Hydrostatic head level transmitter 825B091C Features Power supply: Measuring Range: Output: Overload Capacity: 12,5 36Vdc (2-wired) 0 100m (max.) 4 20mA 1.5 Times of F.S Max. accuracy: ±0.1%FS Typical

More information

CONDUCTIVE LEVEL PROBE

CONDUCTIVE LEVEL PROBE CONDUCTIVE LEVEL PROBE The label Trafag Industrial Components extends the Trafag brand name to instruments manufactured by qualified partner companies. Trafag Industrial Components complement the genuine

More information

Series GWL - Radar Level Transmitter for Liquids

Series GWL - Radar Level Transmitter for Liquids TM Series GWL - Radar Level Transmitter for Liquids Bulletin L-GWL Specifications - Installation and Operating Instructions 4-7/16 [112.63] Ø3-19/32 [90.96] 1-9/16 [39.42] 5-19/32 [142.07] 3-17/32 [89.95]

More information

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications Technical Datasheet D Series SMART Pressure Transmitter Model: DPC-2000 Key Features ATEX - Flameproof and Intrinsically Safe IECEx - Flameproof and Intrinsically Safe SIL 2 certificate Compliant to NAMUR

More information

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR200. 5/200 Siemens FI Configuration.

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR200. 5/200 Siemens FI Configuration. Coni Fl at Overview Configuration Installation min. 300 mm (1 ft) for every 3 m (10 ft) of vessel wall. Note: Beam angle is the width of the cone where the energy density is half of the peak energy density.

More information

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview Siemens AG 2009 Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration

More information

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR200. 5/200 Siemens FI Overview.

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR200. 5/200 Siemens FI Overview. Overview Configuration Installation min. 300 mm (1 ft) for every 3 m (10 ft) of vessel wall. Note: Beam angle is the width of the cone where the energy density is half of the peak energy density. The peak

More information

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0. Technical Information Condumax W CLS9 Conductivity sensors Two-electrode sensors with cell constants k = 0.0 cm or k = 0. cm Application Measurement in pure and ultrapure water: Monitoring ion exchangers

More information