F78MP Series Radar FEATURES AND BENEFITS

Size: px
Start display at page:

Download "F78MP Series Radar FEATURES AND BENEFITS"

Transcription

1 F78MP Series Radar The F78MP Series air radar sensor provides non-contact, continuous level measurement for bulk materials in bins, tanks and silos. Accurate and reliable in difficult environments, the F78MP Series is an ideal level meter for powder and bulk solid inventory management. The F78MP Series air radar withstands corrosive environments and takes consistent measurements in steam, dust and other turbulent conditions. HOW IT WORKS The F78MP Series air radar measures the level of material in a bin or silo by monitoring the time it takes for an emitted microwave pulse to travel from the level meter to the surface of the material being measured and back to the meter. This time is calculated into distance which is then translated into a level measurement. NEW MODELS! Bindicator radar now transmits at a 78 GHz frequency with a 4 degree beam angle. The higher frequency and narrow beam angle combine to create the most versatile radar unit on the market. SIMPLE INSTALLATION with a quick set-up procedure and various mounting options No moving parts and standard air purge for MINIMAL MAINTENANCE FEATURES AND BENEFITS Quick Start Wizard for easy configuration 78 GHz transmitting frequency with a narrow beam angle of 4 Standard, directional or aiming flange options to direct unit to optimal location 2-Wire 20 to 32 VDC Power Supply Measures up to 131 or 328 feet (40 or 100 m) Standard air purge connection ENDLESS APPLICATIONS working in some of the most challenging environments like plastics and powders HOW TO ORDER 2 2 A A 2 Mounting G = 3 Aiming (Directional) Aluminum Flange (Note 2) H = 4 Aiming Aluminum Flange (Note 3) J = 6 Aiming Aluminum Flange (Note 3) K = 3 Stainless Steel Flange (Note 1) L = 4 Stainless Steel Flange (Note 1) M = 6 Stainless Steel Flange (Note 1) Approvals 2 = Hazardous Location MP Series F78MP040 = 131 ft (40 m) Radar F78MP100 = 328 ft (100 m) Radar NOTES: 1. Standard flanges are not pressure rated; atmospheric pressure only in. Directional flange is a split flange and has 5 degree rotation; 3 bar pressure rating and 6 in. Aiming flange has 10 degree rotation; 3 bar pressure rating.

2 F78MP Series Radar SPECIFICATIONS FUNCTIONAL Power Supply Nominal 24 VDC with max 550 Ohm loop resistance; Maximum 30 VDC Dead Zone 15.7 in. (400 mm) from refererence point Measurable Distance 131 ft (40 m) or 328 ft (100 m) Transmitting frequency 78 to 79 GHz FMCW Update Time Maximum 10 seconds (depends on Settings) Beam angle 4 degrees PERFORMANCE Accuracy 0.2 in. (5mm) including hysteresis and non-repeatability Ambient Temperature -40 to 175 F (-40 to 80 C) Ambient Pressure 12 to 15 psi ( 860 to 1060 mbar) Process Temperature -40 to 392 F (-40 to 200 C) Output signal 4 to 20 ma, HART HART Communication Load 230 to 550 Ohm; 230 to 500 Ohm when connecting a coupling module Maximum Line Length 4,921 ft (1500 m) multi-wire Humidity 45 to 75% relative humidity Dielectric Constant Minimum dk of 1.6 for ranges up to 65.6 ft (20 m) Minimum dk of 2.5 for ranges up to 328 ft (100 m) PHYSICAL Material Powder coated 316 Stainless Steel Protection Type 4X/NEMA 4X; Type 6/NEMA6, IP68 Conduit Entry 1/2 NPT Mass 6.94 lb (3.15 kg) (with 3 SS flange) Mounting 3, 4 or 6 in. flat flange or 3 in. Directional flange with 5 rotation or 4 or 6 in. Aiming flange with 10 rotation APPROVALS & RATINGS FM and CSA (US and Canada) Hazardous: Dust Ignition Proof: Class II, Div1, Groups E, F, G; Class III T4 Hazardous: Non-incendive: Class I, Div 2, Groups A, B, C, D, T4 CE Electromagnetic Compatibility Directive Low Voltage Directive DIMENSIONS Universal Flange 4.33 [110.00] 3 : 7.87 [200.00] 4 : 6": [229.00] [285.00] 6 : [285.00] 3 in. Directional Flange 4.33 [110.00] 7.87 [200.00] 4 and 6 in. Aiming Flange Dimensions available at 6.93 [176.00] 0] [9.60] 6.54 [166.10].92 [23.3] sensor reference point 150 Venture Boulevard Spartanburg, SC Tel: (800) (864) Fax: (864) sales@bindicator.com Order from: C A Briggs Company; 622 Mary Street; Suite Warminster, PA Phone: Fax: ; Sales@cabriggs.com - MPR Rev. B 2016 All rights reserved. All data subject to change without notice.

3 TDR-2000 DESCRIPTION The TDR-2000 provides continuous, non-mechanical level measurement, utilizing guided wave radar technology. The TDR-2000 is particularly suited for measuring the level of solids, granules, and powders, as well as a wide range of liquids. For many applications, the TDR-2000 is an economical and superior alternative to capacitance, ultrasonic, and plumb bob technologies. HOW IT WORKS The TDR-2000 two-wire guided microwave level transmitter uses the TDR (Time Domain Reflectometry) principle. The instrument sends low power nanosecond-wide pulses along an electrically conductive rod, cable, or coaxial probe with a known propagation speed (the speed of light). As the pulse reaches the surface of the medium (altered dielectric constant Ԑr), a part of it is reflected back to the electronic module. The efficiency of the reflected signal depends on the dielectric constant (Ԑr) difference of the mediums. The reflected pulse is detected as an electrical voltage signal and is then processed by the electronics. Level distance is directly proportional to the flight time of the pulse. The measured level data is converted to 4-20 ma current and HART signals and is displayed on the LCD display. From the level data, further derived measuring values can be calculated such as volume and mass. The TDR-2000 is unaffected by the other properties of the medium as well as that of the space above it. FEATURES AND BENEFITS Flexibility for a wide range of applications Suitable for a broad range of tank sizes, geometries, and internal constructions Ideal for dirty service applications Accurate and reliable level measurement across a range of dynamic process conditions Insensitive to changes in dielectric, pressure, conductivity, vacuum, humidity, dust, viscosity, vapor, foam, ph, bulk density, temperature, or turbulence Unaffected by filling or emptying conditions such as dust, noise, and material movement Easy Installation Simple to install in new tanks or retrofit existing tanks Can be installed while tank is in service Does not require special configuration to compensate for environmental or structural conditions Low Maintenance Factory calibrated and configured Transmitter design minimizes maintenance requirements HOW TO ORDER TDR A Serial Adapter (Note 2) N = No Adapter Y = RS-422/485 Enclosure (Note 2) N = No Enclosure E = Plastic Enclosure Display Type Blank = None (Note 2) 6R0 = VAC with no relays 6R2 = VAC with two (2) relays 6H0 = VAC with no relays, with Sunbright display 6H2 = VAC with two (2) relays, with Sunbright display 7R0 = VDC with no relays 7R2 = VDC with two (2) relays 7H0 = VDC with no relays, with Sunbright display 7H2 = VDC with two (2) relays, with Sunbright display Probe Length, in inches (Note 1) Approvals A = General Purpose (IP67) D = Hazardous Location - Dust (II 1D ia IIIC T85ºC...T110ºC Da) G = Hazardous Location - Gas (II 1G Ex ia IIC or IIIB T6...T4) Voltage A = 18 VDC to 35 VDC TDR-2000 Guided Wave Radar NOTES 1. Maximum probe length is 78.8 ft (24.0 m). 2. If no display is required, leave Display Type, Enclosure and Serial Adapter blank

4 TDR-2000 SPECIFICATIONS FUNCTIONAL Operating Power 24 VDC (18 to 35 VDC) Ex Version: 24 VDC (18 to 28 VDC) Ambient Temperature -4 to 140 F (-20 to 60 C) Process Temperature Operating Pressure -22 to 212 F (-30 to 100 C) Flange: -22 to 194 F (-30 to 90 C) 580 psig (40 bar) Cable length < 33 ft. (10 m); accuracy is ± 0.8 (20 mm) Accuracy Cable length > 33 ft. (10 m); accuracy is ± 0.20% of length Dielectric Constant > 2.1 Output 4-20mA, HART Communication, terminal resistor 750 Ohm max PERFORMANCE Flexible Probe: Max of 79 ft (24.0 m) Measuring Range Deadband Top: 15.8 (40 cm) if Ԑr < 10; 11.8 (30 cm) if Ԑr > 10 Deadband Bottom: 14.2 (36 cm) Counter Weight Diameter: 1.6 (4 cm); length 10.2 (26 cm) Repeatability 0.04 (1 mm) PHYSICAL Process Connection 1½ MNPT Ingress Protection 1P67 (NEMA 4-4X) Conduit Connections (2) M20 x 1.5 and (2) ½ NPT Electrical Protection Class III Probe Materials Flexible 316 Stainless Steel Cable Enclosure Materials Aluminum with white epoxy coating Gasket Materials FPM (Viton ), FFKM Perfluoroelastomer (Kalrez 6375), EPDM Shipping Weight (Head Unit) 3.3 lb (1.5 kg) APPROVALS: ATEX MARKINGS II 1G Ex ia IIB T6...T4 Ga II 1G Ex ia IIC T6...T4 Ga II 1D Ex ia IIIC T85 C...T110 C PER THE FOLLOWING STANDARDS: MSZ EN :2013 MSZ EN :2013/A11:2014 MSZ EN :2012 T ambient = -20 C C POWER SUPPLY AND LOCAL DISPLAY The PRD1000 is a power supply and local display meter ideal for level, flow rate, temperature, or pressure transmitter applications. Available in VAC or VDC with up to two relays. It has a dual-line 6-digit display, advanced signal input conditioning, function keys, and Modbus RTU serial communications. The basic model includes an isolated 24 VDC transmitter power supply that can be used to power the input transmitter or other devices. A NEMA 4X enclosure is optional, as well as, an RS-485 serial adapter. PRD1000 in NEMA 4X Enclosure 150 Venture Boulevard Spartanburg, SC Tel: (800) (864) Fax: (864) sales@bindicator.com Order from: C A Briggs Company; 622 Mary Street; Suite Warminster, PA Phone: Fax: ; Sales@cabriggs.com - TDR Rev. F 2016 All rights reserved. All data subject to change without notice.

5 Mark-4 TM /GP-4 TM Yo-Yo TM DESCRIPTION The GP-4 TM and Mark-4 TM Yo-Yo TM sensors are designed to provide accurate, reliable inventory management information for tanks and silos. MARK-4 TM NEMA 4/7/9, shown with standard plastic weight FEATURES AND BENEFITS Silos up to 100 ft (30.5 m) Large range of silo heights can be accommodated 1cm (0.39 inches) Resolution Accurate readings Isolated 4-20 ma Output with Adjustable Span (Reversible) No loop isolator is required when connecting to a PLC or DCS RS-485 Communication MODBUS protocol GP-4 TM NEMA 4, shown with standard plastic weight The GP-4 is housed in a NEMA 4 enclosure. The Mark-4 Yo-Yo sensor is housed in a NEMA 4/7/9 enclosure. The Bindicator remote display/ programmer can request readings, monitor up to 99 GP-4 and Mark-4 sensors, and program silo parameters. The display/programmer is used to configure a single sensor or a whole system. An adjustable autotimer allows the user to set automatic measurement cycles ranging from 2 minutes to 1 week. While in operating mode, the display will show the sensor address, sensor name, measurement in the specified units, percentage, display mode and the status of the current device. The display can be used with GP-4 Display/Programmer or Bindicator ORB TM. HOW TO ORDER N 1 10 CABLE 1 = Polyester 2 = Monofilament, max 40 (12.19m) 3 = Stainless Steel (Mark 4 only) SENSING WEIGHT P = Plastic, Standard D = Stainless Steel Bob F = Stainless Steel Float S = Plastic Spike Weight LP = Low Density Plastic Weight LS = Low Density Stainless Steel Weight PB = PVC Jacketed Bob (Note 1) OUTPUT 1 = MODBUS, 4-20 ma VOLTAGE 1 = 115 VAC 2 = 230 VAC HEATER (NOTE 2) N = Without Motor Heater Y = With Motor Heater GP-4 & MARK-4 YO-YO LBY-4 = GP-4 (NEMA 4) LHY-7 = Mark-4 (NEMA 4/7/9) Note 1: Specify monofilament cable. Note 2: For operation below 32 F (0 C). SENSOR WEIGHT OPTIONS Remote Display Programmer with Keypad 4-line x 20-character backlit LCD display Programmable sensor names and ranges Enable/Disable network addresses P = Plastic, Standard S = Plastic, Spike Weight D = SS Bob

6 Mark-4 TM /GP-4 TM Yo-Yo TM SPECIFICATIONS MARK-4 TM FUNCTIONAL Operating Power Power Consumption Operating Temperature Output PERFORMANCE Repeatability Measurement Span Automatic Timer PHYSICAL Mounting Conduit Entry Air Purge Connection Enclosure Material Enclosure Rating Shipping Weight OPTIONS APPROVALS Mark-4 GP-4 MARK-4/GP-4 YO-YO 115 VAC or 230 VAC 115 VAC, 50/60 Hz, 32 watts (operating), 4 watts (quiescent) (with heater add 10 watts) 32º to 120º F (0º to 49º C); with heater -31º to 120º F (-35º to 49º C) MODBUS, Analog 4-20 ma optically isolated (user sourced) into 600 ohms max 2 cm (0.8 in) Up to 100 ft standard From 2 minutes to 9999 minutes (approx. 1 week) 3 NPT GP-4: 2 each 3 /4 NPT, Mark-4: 3 each 3 /4 NPT 1 /4 NPT GP-4: Minlon frame, low density polyethylene cover Mark-4: Polyester coated cast aluminum GP-4: NEMA 4 Mark-4: NEMA 4/7/9 GP-4:13 lbs (6 kg) Mark-4: 26 lbs (12kg) Motor Heater YoYo Display ORB FM (US) - XP Class I, Division I, Groups C and D; T5, Ta= 60º C DIP Class II, III, Division I, Groups E, F, and G; T5, Ta= 60º C; Type 4 CSA - Class I, Groups C and D; Class II, Groups E, F and G; Class III; Type 5; Type 4 ATEX FM (US) - General Purpose CE GP-4 TM

7 Display / Programmer DESCRIPTION The display/programmer allows a user to configure a single sensor or a whole system. An adjustable autotimer allows the user to set automatic measurement cycles ranging from 2 minutes to 1 week. While in operating mode, the display will show the sensor address, sensor name, measurement in the specified units, percentage, display mode and the status of the current device. FEATURES AND BENEFITS Remote Sensor Set-up and Configuration Allows end user to set-up system from any location Remote Measurement Request and Display Monitors up to 99 sensors from up to 4000 feet 4-line x 20 Character Backlit LCD Display Easy to read level, sensor name and status RS-485 Communication MODBUS protocol Optional Heater Keeps system running smoothly in temperatures below -4 F (-20 C) HOW TO ORDER LBY-4 M 0 10 HEATER (See Note 1) A = Without Heater B = 115 VAC Heater C = 230 VAC Heater COMMUNICATIONS M = MODBUS DISPLAY / PROGRAMMER Note 1: For operation below -4 F (-20 C) SYSTEM CONFIGURATION * See ORB Technical Sheet for Specifications.

8 Display / Programmer SPECIFICATIONS DIMENSIONS FUNCTIONAL Display / Programmer Powered from Yo-Yo sensor Operating Power (9-24 VDC); With optional heater, 120/240 VAC required -4 F to 158 F (-20 C to 70 C); Operating with optional heater: Temperature -40 F to 158 F (-40 C to 70 C) PHYSICAL Communication RS-485 MODBUS Optional integral modem Sensors Up to 99 Display 4 lines by 20 characters Backlit LCD display Keypad NEMA 4X soft-touch Enclosure NEMA 4X molded fiberglass polyester PERFORMANCE Wiring Requirements Belden 9842, 4 wire shielded cable Wiring Distance 4000 max Speed 115 Kbps Protocol MODBUS Interface RS-485 Internal Modem Optional 56K Modem Minlon is a registered trademark of E.I. Du Pont Belden is a registered trademark of Belden Inc. 150 Venture Boulevard Spartanburg, SC Tel: (800) (864) Fax: (864) sales@bindicator.com Order from: C A Briggs Company; 622 Mary Street; Suite Warminster, PA Phone: Fax: ; Sales@cabriggs.com - LBY Rev. G 2015 All rights reserved. All data subject to change without notice.

9 SonoTracker TM FEATURES AND BENEFITS Quick Configuration Menu driven quick set up in less than 5 minutes. Digital Connection to ORB (RS-422) Modular Design Configurable for number of sensors, relays, point level inputs, current loops, and PLC interfaces. Multiple Functions In One Unit Solids and liquid level, open channel flow, and differential level measurement. Adjusts systems parameters and pre-calibrates unit without special software. Continuous Non-Contact Level Measurement No contamination of material, no lost parts or cables, no material build-up on sensing cables/surfaces. Sentry DSP Provides stable and accurate reading under process conditions. NEMA-4X Enclosure FRP or optional stainless steel offers the right protection for your environment. Built-in Optically Isolated Serial Port Versatile interfacing for data collection, servicing and building large multi-vessel communications systems. DESCRIPTION The SonoTracker TM Ultrasonic Level System can monitor up to 16 vessels with transducers of various frequencies, and vessels of different heights and shapes and accurately measure the level of many different materials. It allows you to read levels from 1 foot to beyond 100 feet in solids, and additionally the same unit can be used for open channel flow and differential level measurements. HOW TO ORDER SON SLOT 3 CARD OPTIONS A = None C = 5 Output Relay Card D = 8 Output Relay Card E = 2 Output Relays with 1-Channel 4-20mA Card (AC Power Only) ED= 2 Output Relays with 1-Channel 4-20mA Card (AC/DC) G = 8-Channel 4-20mA Output Card (AC Power Only) H = 4-Channel 4-20mA Output Card (AC Power Only) I = 2-Channel 4-20mA Output Card (AC Power Only) N = 4 Output Relays with 2-Channel 4-20mA Card (AC Power Only) ND= 4 Output Relays with 2-Channel 4-20mA Card (AC/DC) Q = ProfiBus DP Card S = Point Level Input Card SLOT 2 CARD OPTIONS A = None B = 8 Vessel Scanner Card C = 5 Output Relay Card D = 8 Output Relay Card J = 4 Vessel Scanner Card K = 2 Vessel Scanner Card Q = Profibus DP Card S = Point Level Input Card SLOT 1 CARD OPTIONS A = None B = 8 Vessel Scanner Card J = 4 Vessel Scanner Card K = 2 Vessel Scanner Card HEATER * Y = Yes N = No ENCLOSURE TYPE A = NEMA 4X Fiberglass B = NEMA 4X Stainless Steel OPERATING VOLTAGE A = 110 VAC B = 24 VDC D = 220 VAC SONOTRACKER TM LEVEL MONITOR with Serial Output Isolator and Backlight Display * For use below -5º F (-20º C)

10 SonoTracker TM SPECIFICATIONS FUNCTIONAL SonoTracker TM 110/230 VAC (+/- 10%) 50/60 Hz Operating Power or 24 VDC Power Requirement 20 VA Operating Temperature -5º to 122º F (-20º to 50º C) Measuring Distance 1 to 100 depending on sensor PERFORMANCE Transducer Frequencies from 10 KHz to 45 KHz Compatibility Non-volatile RAM, common isolation Memory parameter storage Form C SPDT, programmable, 10 A 110 VAC, 8 A 230 VAC noninductive, 10 A 30 VDC; available as plug in modules of 2, 4, 5 and 8 relays each 4-20 ma option: Isolated 600 ohms maximum or externally powered to 1000 ohms, 12 bit resolution; Relay Output available as plug in modules of 2, 4, and 8 outputs with common isolation; must be installed in third option slot Combi-Card option: One combicard per unit; combinations are 2 relays, 1 current; or 4 relays, 2 currents 32 channel block transfer, 6 channel PLC Interface Option discreet transfers, Profibus-DP Slave PHYSICAL NEMA 4X fiberglass reinforced Enclosures polyester (FRP) or NEMA 4X Stainless Steel Large, back lit alphanumeric liquid crystal, two lines of 16 characters, Display user programmable IDs, selectable bar graph disply or engineering units formats

11 SonoTracker TM DESCRIPTION The range of sensors allows you to read levels from 1 foot to beyond 100 feet in solids. The BT-55 transducer has an extremely narrow beam angle, allowing it to be used in challenging applications. Additionally, the same unit also performs open channel flow and differential level measurements. FEATURES AND BENEFITS Versatility The transducers are designed for your specific application and environment. Available in frequencies of 14kHz, 22kHz, 24 khz and 43kHz to fit a variety of materials and distances. Accuracy 1% of rated span in approved bulk solids applications 0.25% of rated span in approved liquid applications HOW TO ORDER SON BT-26 PVC Sensor SON BT-26 PVC Sensor with TC SON200058** BT-26 Stainless Steel Sensor SON200069** BT-26 Stainless Steel Sensor with TC SON200084SVB BT-50 PVC Sensor SON200057SVB BT-50 PVC Sensor with TC SON200085* BT-55 PVC Sensor SON BT-61 PVC Sensor SON BT-61 PVC Sensor with TC SON BT-101 PVC Sensor SON BT-101 PVC Sensor with TC SON Junction Box, NEMA 4x with 5 terminal connections External temperature probe Aiming Kit (excluding BT-55) Aiming Kit (BT-55 Only) NOTES: Non-pressurized flanges with standard ANSI 150 lb bolt hole configurations are available in 3, 4, 6, 8 and 12. Use part number for sensor cable and LUC for temperature compensation cable. * This sensor not FM Approved APPROVALS Transducers are FM approved: S Class I, II, III; Division I, Groups C, D, E, F and G; T5 **3A (Transducer Specific) BT-26 Stainless Steel Sensor BT-101 PVC Sensor BT-55 PVC Sensor

12 SonoTracker TM TRANSDUCER SPECIFICATIONS Nominal Range Liquids Nominal Range Solids Minimum Range BT-26PT 25 (7.6m) 15 (4.6m) 12 (305mm) BT-26ST 25 (7.6m) 15 (4.6m) 12 (305mm) BT-61PT 50 (15.2m) 30 (9.2m) 24 (610mm) BT-50PT 50 (15.2 m) 50 (15.2 m) 36 (914mm) BT-55 BT-101PT 100 (30.5m) 125 (38.1m) 50 grains 100 plastics 100 (30.5m) 24 (610mm) 36 (914mm) Temperature Range Weight Frequency Beam Angle -40 to 160 F (-40 to 71 C) -40 to 230 F (-40 to 110 C) -40 to 160 F (-40 to 71 C) -40 to 160 F (-40 to 71 C) -40 to 160 F (-40 to 71 C) -40 to 160 F (-40 to 71 C) 1.2 lbs (0.5 kg) 1.2 lbs (0.5 kg) 3.1 lbs (1.4 kg) 5.75 lbs (2.6 kg) 13.0 lbs (5.9kg) 5.75 lbs (2.6 kg) 43KHz 43KHz 22KHz 14KHz 24KHz 14KHz 12 included 12 included 12 included 12 included 5 included 12 included TRANSDUCER MOUNTING DIMENSIONS A B BT-26PT 5.2 (132.1mm) 2.3 (58.41mm) BT-26ST 5.5 (139.7mm) 2.5 (63.5mm) BT-61PT 6.9 (175mm) 4.2 (107mm) BT-50PT 9.2 (233.7mm) 5.5 (139.7mm) BT (463.6mm) 7.12 (180.8mm) BT-101PT 9.2 (233.7mm) 5.5 (139.7mm) 1 NPT 1 NPT PT ST A B B TRANSDUCER SELECTION BY PRODUCT A 1 NPT BT-55 B A 150 Venture Boulevard Spartanburg, SC Tel: (800) (864) Fax: (864) sales@bindicator.com Order from: C A Briggs Company; 622 Mary Street; Suite Warminster, PA Phone: Fax: ; Sales@cabriggs.com - SON Rev. K 2016 All rights reserved. All data subject to change without notice.

13 Cap-Level IIA DESCRIPTION Cap-Level IIA is designed for level monitoring and control. The 4-20mA output provides a selectable dampening function to stabilize readings where severe agitation is present. Simple zero and span adjustment make calibration easy. The relay logic circuitry offers the flexibility to control multiple pumps, conveyors, and alarms. Each relay can be set to turn your equipment on and off at any selected point on the probe, without any external latching devices. Failsafe selection gives the security of fault indication and/or conveyor stop if power is lost. The probe configurations and materials offered allow you to custom fit Cap-Level IIA to your application. Designs such as the type E and H tie-down, allow use in tall silos and include a unique cable tightening adjustment. HOW TO ORDER CL 2A 4 10 FEATURES AND BENEFITS Two-wire transmitter (24 VDC) Senses practically any liquid Electronic options Rigid or flexible probes FM approved for hazardous areas Continuous 4-20mA Standard Communication Output Dampening - Standard Stabilizes readings where severe agitation is present Teflon, PVC, and 316 SS Probes and NPT or Flange Mounting Options for a wide range of applications Continuous Process Management Uninterrupted level measurement All models intrinsically safe when used with approved barriers. MODIFICATION (Note 1) A = No Lagging Extension B = With 10 SS Lagging Extension FLANGE MATERIAL 1 = None 2 = 316 SS 3 = Carbon Steel 4 = Teflon Faced 316 SS (Note 2) 5 = Teflon Faced Carbon Steel (Note 2) FLANGE OPTION A = None B = lb C = lb D = lb E = lb S = Special PROBE LENGTH (NOTE 3 & 4) PROBE TYPE A = 316 SS Solid Probe (Note 5) B = Teflon Jacketed Solid Probe D = Bare SS Cable, SS Weight (Note 5) E = Bare SS Cable, Tie Down Assembly (Note 5) H = Teflon Jacketed Cable, Tie Down Assembly I = Teflon Jacketed Cable, Teflon Jacketed Weight M = PVC Jacketed Solid Probe N = Teflon Jacketed Solid With 1 Sanitary Mount P = 316 SS Solid with 1 Sanitary Mount (Note 5) Q = Teflon Jacketed Solid Probe With 2 Sanitary Mount VOLTAGE 4 = 24 VDC (External Loop Power Supply Required) ENCLOSURE G = General Purpose, NEMA 4X R = NEMA 4X, Remote Cable Required SERIES-IIA 2A = 2 Wire Analog (4-20mA) CAP-LEVEL IIA Note 1. Lagging assembly is used for high temperature applications. Note 2. All models are intrinsically safe when used with approved barriers. Note 3. Maximum standard length for solid probes is 14 (4.2m). For probes exceeding this length consult factory. Note 4. Maximum standard length for cable probes is 100 (30.5m). For probes exceeding this length contact factory. Note 5. For dry or non-conductive materials only.

14 Cap-Level IIA SPECIFICATIONS PROBE APPLICATION FUNCTIONAL Power Output Drive Capability Calibration Capacitance Range Repeatability Sensing System PHYSICAL Enclosure Enclosure Temperature Length APPROVALS VDC (27 VDC max. for LS operation) 4-20mA VDC (varies with voltage) Zero and span with frequency selection 0 pf to 4000 pf nominal ±1% of span (constant dielectric) High frequency capacitance with digital comparator NEMA 4X, aluminum with corrosion resistant polyester coating -40 F to 120 F (-40 C to 49 C) (lagging assembly for higher temperature) As specified - Types A, B, M, N, P, Q: 167 (4175mm) maximum; Types D, E, H, I: 1200 (36000mm) maximum Hazardous Location: FM, Intrinsically safe, Class I, II, III, Div I, Groups C, D, E, F & G Type 4, T4A Probe Type Mount Standard Material A ¾ NPT 316 SS** B ¾ NPT Teflon /SS Pressure (Max) D 1¼ NPT 316 SS** Atmospheric E 1¼ NPT 316 SS** Atmospheric H 1¼ NPT Teflon /SS Atmospheric I 1¼ NPT Teflon /SS M ¾ NPT PVC/SS N 1 Sanitary Teflon /SS P 1 Sanitary 316 SS Q 2 Sanitary Teflon /SS Temp. (Max) 140 F (60 C) ** Probe types A, D, E non-conductive media only. Use auxiliary ground rod or stilling well (reference ground) in fiberglass or lined vessels. Teflon is a registered trademark of E.I. Du Pont, All rights reserved. TYPE B PROBE 150 Venture Boulevard Spartanburg, SC Tel: (800) (864) Fax: (864) sales@bindicator.com Order from: C A Briggs Company; 622 Mary Street; Suite Warminster, PA Phone: Fax: ; Sales@cabriggs.com - SCL Rev. E 2012 All rights reserved. All data subject to change without notice.

15 Cap-Level II DESCRIPTION Cap-Level II is designed for level monitoring and control. The 4-20mA output provides a selectable dampening function to stabilize readings where severe agitation is present. Simple zero and span adjustment make calibration easy. The relay logic circuitry offers the flexibility to control multiple pumps, conveyors and alarms. Each relay can be set to turn your equipment on and off at any selected point on the probe - without any external latching devices. Failsafe selection gives the security of fault indication and/or conveyor stop if power is lost. The probe configurations and materials offered allow you to custom fit Cap-Level II to your application. Designs such as the type E and type H tie-down, allow use in tall silos and include a unique cable adjustments. HOW TO ORDER CL 30 FEATURES AND BENEFITS Continuous 4-20mA Standard Communication Output Dampening - Standard Stabilizes readings where severe agitation is present Teflon, PVC, 316 SS Probes and NPT or Flange Mounting Options for a wide range of applications Continuous Process Management Uninterrupted level measurement DESIGN LEVEL (Assigned by Factory) PROBE LENGTH (Specify inches, see Notes 1, 2) PROBE TYPE A = 316 SS Solid Probe (See Note 3) B = Teflon Jacketed Solid Probe D = Bare SS Cable, SS Weight (See Note 3) E = Bare SS Cable, Tie Down Assmbly (See Note 3) H = Teflon Jacketed Cable, Tie Down Assembly I = Teflon Jacketed Cable, Teflon Jacketed Weight M = PVC Jacketed Solid Probe N = Teflon Jacketed Solid With 1 Sanitary Mount P = 316 SS Solid with 1 Sanitary Mount (See Note 3) Q = Teflon Jacketed Solid Probe With 2 Sanitary Mount VOLTAGE 1 = 120 VAC 2 = 240 VAC ENCLOSURE G = General Purpose - NEMA 4X X = Explosion-Proof - NEMA 7/9 (See Note 4) SERIES 3 = Continuous with No Relays 4 = Continuous with 1 Relay 5 = Continuous with 2 Relays CAP-LEVEL II Note 1. Note 2. Note 3. Note 4. Maximum standard length for solid probes is 167 (4242mm). For probes exceeding this length contact factory. Maximum standard length for cable probes is 1200 (30480mm). For probes exceeding this length contact factory. For dry or non-conductive materials only. Type B probe only.

16 Cap-Level II SPECIFICATIONS FUNCTIONAL Operating Power 120 VAC, 240 VAC Power Consumption 8 Watts Operating Temperature -40º to 160º F (-40º to 71º C) PERFORMANCE Hysteresis 2.5% of span min, 100% max Analog Output 4-20mA into 400 Ohms max Relay Output SPDT, VAC Accuracy 1% FS with Constant Dielectric Analog: course and fine zero/ span, non-interacting relays: hi, low Calibration setpoints and hysteresis set as % of span PHYSICAL NEMA 4X or NEMA 7/9 aluminum Enclosure with corrosion resistant polyester coating As specified for Types A, B, M, N, P, Length Q:167 (4157 mm), Types D, E, H, I: 1200 (36000 mm) APPROVALS General Purpose: CSA; Type 4 PROBE APPLICATION Probe Type Mount Standard Material A ¾ NPT 316 SS** B ¾ NPT Teflon /SS Pressure (Max) D 1¼ NPT 316 SS** Atmospheric E 1¼ NPT 316 SS** Atmospheric H 1¼ NPT Teflon /SS Atmospheric I 1¼ NPT Teflon /SS M ¾ NPT PVC/SS N 1 Sanitary Teflon /SS P 1 Sanitary 316 SS** Q 2 Sanitary Teflon /SS Temp. (Max) 140 F (60 C) ** Probe types A, D, E - non-conductive media only. Consult factory when mounting in fiberglass or lined vessels. Teflon is a registered trademark of E.I. Du Pont, All rights reserved. Hazardous Location: CSA; Class I, Groups C and D 150 Venture Boulevard Spartanburg, SC Tel: (800) (864) Fax: (864) sales@bindicator.com Order from: C A Briggs Company; 622 Mary Street; Suite Warminster, PA Phone: Fax: ; Sales@cabriggs.com - SCL Rev. E 2012 All rights reserved. All data subject to change without notice.

THE ORIGINAL DRY BULK LEVEL MEASUREMENT & CONTROL

THE ORIGINAL DRY BULK LEVEL MEASUREMENT & CONTROL THE ORIGINAL DRY BULK LEVEL MEASUREMENT & CONTROL This catalog was published in 1964, nearly 30 years after Bindicator began serving the industry. THe original Since 1936, Bindicator has manufactured level

More information

NUS-4. Ultrasonic Level Transmitter. for Liquids and Solids

NUS-4. Ultrasonic Level Transmitter. for Liquids and Solids Ultrasonic Level Transmitter for Liquids and Solids measuring monitoring analyzing 4 Measuring Ranges: Liquids: Up to 25 meters (80 feet) Solids: Up to 10 meters (32 feet) Accuracy: ± 0.2 % of Reading

More information

DREXELBROOK. IMPULSE Series. Guided Wave Radar (TDR) Easy to install, Easy to use. Dependable performance. The New Impulse Guided Wave Radar

DREXELBROOK. IMPULSE Series. Guided Wave Radar (TDR) Easy to install, Easy to use. Dependable performance. The New Impulse Guided Wave Radar DREXELBROOK A Leader In Level Measurement Solutions IMPULSE Series Guided Wave Radar (TDR) and Volumetric for Total Level Measurements TDR Level Measurement Easy to install, Easy to use TDR Level Measurement

More information

DREXELBROOK. IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements. Easy to install, Easy to use. Dependable performance

DREXELBROOK. IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements. Easy to install, Easy to use. Dependable performance DREXELBROOK A Leader In Level Measurement Solutions IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements TDR Level Measurement Easy to install, Easy to use TDR Level Measurement

More information

Level Measurement Continuous level measurement Radar transmitters

Level Measurement Continuous level measurement Radar transmitters Overview Benefits Process Intelligence for advanced signal processing and quick and easy adjustment Self-guided quick start wizard for plug and play startup 2 GHz provides superior reflective properties

More information

TEK-F LEX 4100A. Guided Wave Radar Level Transmitter. LEVEL. Technology Solutions

TEK-F LEX 4100A. Guided Wave Radar Level Transmitter.   LEVEL. Technology Solutions Technology Solutions TEK-F LEX 4100A Guided Wave Radar Level Transmitter LEVEL www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Featuring TDR (Time Domain

More information

Level Measurement Continuous level measurement Radar transmitters

Level Measurement Continuous level measurement Radar transmitters Overview Configuration Mounting on a nozzle is a 2-wire 25 GHz pulse radar level transmitter for continuous monitoring of solids and liquids in storage vessels including extreme levels of dust and high

More information

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI Overview The is a -wire, 2 GHz FMCW radar level transmitter with extremely high signal-to-noise ratio and advanced signal processing for continuous monitoring of solids up to 100 m (328 ft). It is ideal

More information

DREXELBROOK DREXELBROOK. Impulse. Series IMPULSE. IMPULSE Series. Guided Wave Radar (TDR) for Total Level and Volumetric Measurements DATA SHEET

DREXELBROOK DREXELBROOK. Impulse. Series IMPULSE. IMPULSE Series. Guided Wave Radar (TDR) for Total Level and Volumetric Measurements DATA SHEET t DREXELBROOK DATA SHEET DREXELBROOK A Leader In Level Measurement Solutions IMPULSE Series IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements TDR Level Measurement Easy

More information

SITRANS LR 300: High Performance Radar for Level Measurement

SITRANS LR 300: High Performance Radar for Level Measurement SITRANS LR 300: High Performance Radar for Level Measurement Reliable Measurement In Extreme Conditions SITRANS LR 300 delivers high performance level measurement at an affordable price for the chemical,

More information

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA Mobrey Ultrasonic Product Data Sheet February 215 IP245, Rev EA MSP422, MSP4RH, and MSP9GH Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for

More information

Level Measurement With REFLEX RADAR

Level Measurement With REFLEX RADAR Reflex Radar & TDR HYC-RR02 Elect. Iss. 02 Level Measurement With REFLEX RADAR Why Radar Technology for Level Measurement? INSENSITIVE TO CHANGES IN Dielectric Pressure Vacuum Humidity Dust Viscosity Foam

More information

Specification DataFile

Specification DataFile DATUM U & U Ultrasonic Level System Specification DataFile 6-digit backlit l.c.d. and bargraph clear display of measured level Echo Processing using 'DATEM' software true level measurement, overcoming

More information

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily

More information

REFLEX RADAR INDICATOR

REFLEX RADAR INDICATOR REFLEX RADAR INDICATOR Why Radar Technology for Level Measurement? INSENSITIVE TO CHANGES IN Dielectric Pressure Vacuum Humidity Dust Viscosity Foam Temperature THE ADVANTAGES ARE Measuring ranges up to

More information

Kotron Sentinel Model 804 RF Level Transmitter

Kotron Sentinel Model 804 RF Level Transmitter Kotron Sentinel Model 804 RF Level Transmitter D E S C R I P T I O N The Sentinel is a unique, powerful level transmitter. The leading-edge microprocessor-based circuitry has nonvolatile memory. The display

More information

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

Model Sono-Trak Transit Time

Model Sono-Trak Transit Time Model Sono-Trak Transit Time Ultrasonic Flow Meter Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive, bi-directional measurement with advanced ultrasonic

More information

Level Measurement With REFLEX RADAR

Level Measurement With REFLEX RADAR Reflex Radar & TDR HYC-RR03 Elect. Iss. 03 Level Measurement With REFLEX RADAR Why Radar Technology for Level Measurement? INSENSITIVE TO CHANGES IN Dielectric Pressure Vacuum Humidity Dust Viscosity Foam

More information

Level gauges Series LT Level indicator, switch and transmitter for liquids

Level gauges Series LT Level indicator, switch and transmitter for liquids Level gauges Series LT Level indicator, switch and transmitter for liquids Simple construction Resistant under extreme temperature and pressure conditions No risk of leakage Excellent chemical resistance

More information

Radar Level Measurement micropilot FMR 130 for stilling wells

Radar Level Measurement micropilot FMR 130 for stilling wells Technical Information TI 258F/24/ae Radar Level Measurement micropilot FMR 130 for stilling wells Smart transmitter for non-contact measurement in metallic by-pass pipes and stilling wells Suitable for

More information

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview Overview Application It provides excellent results on low dielectric media. is available for standard applications and for applications that require explosion proof protection. features robust enclosure,

More information

LHY Rev. C. Mark-4 Yo-Yo. Inventory Management System

LHY Rev. C. Mark-4 Yo-Yo. Inventory Management System LHY280400 Rev. C Mark-4 Yo-Yo Inventory Management System INSTALLATION, OPERATION & MAINTENANCE MANUAL SAFETY INFORMATION Before installing the Mark-4 Yo-Yo Inventory Management System, please read these

More information

LST100 Ultrasonic level transmitter for upstream oil and gas

LST100 Ultrasonic level transmitter for upstream oil and gas Data sheet DS/LST100-EN LST100 Ultrasonic level transmitter for upstream oil and gas Accurately track and measure the most expensive consumable on your site chemicals. Measurement made easy Features Keep

More information

Kotron Model 82 CE RF Level Transmitter

Kotron Model 82 CE RF Level Transmitter Kotron Model 82 CE RF Level Transmitter DESCRIPTION The Kotron Model 82 RF Capacitance transmitter is one of the most cost effective level transmitters available today. Compact in size, it employs state-of-the-art

More information

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview Overview Application It provides excellent results on low dielectric media. is available for standard applications and for applications that require explosion proof protection. features robust enclosure,

More information

SITRANS L Level instruments

SITRANS L Level instruments SITRANS L Level instruments /2 Point level measurement /6 Capacitance switches /9 Pointek CLS100 /1 Pointek CLS200 /31 Pointek CLS300 /47 Pointek CLS00 /62 Pointek Specials Electro-mechanical switches

More information

Kotron Sentinel Model 804 RF Level Transmitter

Kotron Sentinel Model 804 RF Level Transmitter Kotron Sentinel Model 804 RF Level Transmitter D E S C R I P T I O N The Sentinel is a unique, powerful level transmitter. The leading edge microprocessor-based circuitry has nonvolatile memory. The display

More information

Rosemount 3101, 3102, and 3105

Rosemount 3101, 3102, and 3105 Product Data Sheet February 2013 00813-0100-4840, Rev DA Rosemount 3101, 3102, and 3105 Ultrasonic Liquid Level Transmitters Non-contacting measurement with no moving parts Integral LCD and buttons as

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter ABB MEASUREMENT & ANALYTICS DATA SHEET Ultrasonic level LST400 Open channel flow transmitter 2 ULTRASONIC LEVEL LST400 / OPEN CHANNEL FLOW TRANSMITTER DS/LST400 EN REV. D Measurement made easy Reduced

More information

Echotel Trident 91S/92S Ultrasonic Level Switches

Echotel Trident 91S/92S Ultrasonic Level Switches Echotel Trident 91S/92S Ultrasonic Level Switches D E S C R I P T I O N The Trident 91S/92S detects single or dual point level in a wide variety of liquid applications. It is available with either an ma

More information

LEVEL Transmitters. SAP-300 display. Mono cable / Mono rod Mono segmented rod. Twin cable Twin rod Coaxial Pipe

LEVEL Transmitters. SAP-300 display. Mono cable / Mono rod Mono segmented rod. Twin cable Twin rod Coaxial Pipe Guided microwave level transmitters GENERAL DESCRITION The Guided Wave Radar level transmitter is designed for continuous level measuring of conductive or non-conductive liquids, pulps and solids. level

More information

Ultrasonic level transmitter, non-contact

Ultrasonic level transmitter, non-contact Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration:

More information

Technologies, Solutions, and Applications. Guided Wave Radar for Level

Technologies, Solutions, and Applications. Guided Wave Radar for Level Technologies, Solutions, and Applications Guided Wave Radar for Level Contents Leadership in Guided Wave Radar 3 Principles of Operation 4 Models and Versions 5 Guided Wave Radar in the plics System 8

More information

LST400 Ultrasonic level / open channel flow transmitter

LST400 Ultrasonic level / open channel flow transmitter Data sheet DS/LST400 EN Rev.C LST400 Ultrasonic level / open channel flow transmitter Measurement made easy Reduced installation cost Easy access terminations Integrated echo display makes for easy troubleshooting

More information

FOSTEN AUTOMATION SÉRIE F500-RD

FOSTEN AUTOMATION SÉRIE F500-RD FOSTEN AUTOMATION SÉRIE Guided Wave Radar Level Transmitter Guided wave radar level transmitter. Low maintenance, auto calibrated references. Easy installation, directly in tanks or auxiliary vessels.

More information

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Sarasota CM200 Sarasota HME900 Density Converter Electronics Sarasota CM00 Sarasota HME00 Density Converter Electronics Users of Sarasota density meters or specific gravity analyzers are offered the choice of a HART compatible, field mounted density converter, or

More information

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement Technical Data Sheet Non-Contact, Multiple-Point Measurement The 3DLevelScanner is a noncontact, dust-penetrating bin measurement device that detects irregular surfaces in powder or solid materials and

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:

More information

TMU. Coriolis Mass Flow Meter. for liquids and gas

TMU. Coriolis Mass Flow Meter. for liquids and gas Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TMU S5 OO Measuring range: 0-60 kg/h 0-2200 t/h water OO Accuracy: ± 0.1% of reading ±zero point stability (from liquids up to

More information

ULTRASONIC LEVEL INDICATOR

ULTRASONIC LEVEL INDICATOR ULTRASONIC LEVEL INDICATOR REFLEX/SCANFLEX MULTIFLEX MINIFLEX LR MICROFLEX-C TYPICAL NON-CONTACT LEVEL METER! OUTSTANDING SOFWARE MAKES HIGHLY STABLE AND RELIABLE. A WIDE RANGE OF S FROM SOLIDS TOLIQUIDS,

More information

Non-Submersible Industrial Pressure Transducer

Non-Submersible Industrial Pressure Transducer Non-Submersible Industrial Pressure Transducer KPSI Transducers Series 27, 28, 30 FEATURES Custom Pressure Ranges up to 2000 (13,790 kpa) Accuracy to ±0.10% FS Analog Outputs of 4-20 ma or VDC Welded 316

More information

Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys

Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Technology Solutions www.tek-trol.com 796 Tek Drive Crystal Lake, IL 60014 USA Tel: +1 847 857 6076, +1 847 655 7428 Fax: +1 847 655 6147 Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys

More information

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications Description The Vortex PhD vortex shedding flowmeter measures process fluid flow by detecting the frequency at which vortices are shed from an obstruction in the process fluid line (the bluff body). A

More information

Echotel Model 910 Ultrasonic Level Switch

Echotel Model 910 Ultrasonic Level Switch Echotel Model 910 Ultrasonic Level Switch D E S C R I P T I O N Echotel Model 910 Level Switches utilize ultrasonic contact technology for measuring level in clean liquid applications. The dual conduit

More information

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement Technical Data Sheet Distribué par : Contact : hvssystem@hvssystem.com Tél : 0326824929 Fax : 0326851908 Non-Contact, Multiple-Point Measurement The 3DLevelScanner is a noncontact, dust-penetrating bin

More information

Level Lance Model 5100

Level Lance Model 5100 Sales Manual Section 100 Product Specification Model 5100 Level Lance Model 5100 GENERAL DESCRIPTION The Robertshaw Model 5100 Level-Lance is a microprocessor based, advanced technology On-Off level detection

More information

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR300. 5/180 Siemens FI Overview

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR300. 5/180 Siemens FI Overview Overview is a 4-wire, 6 GHz pulse radar level transmitter for continuous and process vessels including high temperature and pressure, to a range of 20 m (66 ft). Benefits Auto False-Echo Suppression Infrared

More information

Electro-Magnetic Flowmeters COPA-XE

Electro-Magnetic Flowmeters COPA-XE Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates

More information

RCM DIRECT READING FLOWMETER

RCM DIRECT READING FLOWMETER RCM DIRECT READING FLOWMETER Flow Pressure Level Temperature measurement monitoring control Special Features Compact Design Easy to Install For Horizontal or Vertical Pipes Rugged Construction Accuracy:

More information

Magnetostrictive Level Transmitter

Magnetostrictive Level Transmitter Magnetostrictive Level Transmitter Magnetostrictive Level Transmitter Overview Söm-Tek TM The SKMT liquid level transmitter satisfies the demand for an analog communication interface for sightglass (bypass

More information

WHITE PAPER HOW TO SELECT A CONTINUOUS LEVEL SENSOR BINVENTORY. Jenny Christensen Todd Peterson. BinMaster

WHITE PAPER HOW TO SELECT A CONTINUOUS LEVEL SENSOR BINVENTORY. Jenny Christensen Todd Peterson. BinMaster HOW TO SELECT A CONTINUOUS LEVEL SENSOR Jenny Christensen Todd Peterson BinMaster 1 Using a continuous level sensor to monitor the material level in your storage vessels can help you keep material flowing

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:

More information

Features. NULL-KOTE Circuitry Makes the sensor immune to adverse effects of conductive coating build up.

Features. NULL-KOTE Circuitry Makes the sensor immune to adverse effects of conductive coating build up. Model L2610 Instrumentation designed with the user in mind. NULL-KOTE Self-Diagnostic Analog Level Transmitter Electronic, RF Impedance sensing, with the innovative NULL-KOTE system, which ignores product

More information

Ultrasonic Liquid Level Transmitters

Ultrasonic Liquid Level Transmitters Product Data Sheet Ultrasonic Liquid Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for on-site programming Continuous measurement of level

More information

Level transmitters Series LTDR TDR guided radar level transmitter for liquids and solids

Level transmitters Series LTDR TDR guided radar level transmitter for liquids and solids Level transmitters Series LTDR TDR guided radar level transmitter for liquids and solids Level measurement independent of changing process conditions (density, conductivity, temperature, pressure, ) Innovative

More information

Kotron Sentinel Models 822, 832 and 842 RF Point Level Switches

Kotron Sentinel Models 822, 832 and 842 RF Point Level Switches Kotron Sentinel Models 8, 8 and 84 RF Point Level Switches D E S C R I P T I O N The Sentinel is a powerful multi-point level switch. The microprocessor-based circuitry has non-volatile memory, to protect

More information

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output. Level Plus Magnetostrictive Liquid-Level Sensors with Temposonics Technology M-Series Model MR Transmitter with Analog Output Data Sheet SENSORS Document Part Number 550677 Revision K FEATURES 4 to 20

More information

PNEUMATIC, ELECTRO-PNEUMATIC & SMART DIGITAL.

PNEUMATIC, ELECTRO-PNEUMATIC & SMART DIGITAL. PNEUMATIC, ELECTRO-PNEUMATIC & SMART DIGITAL www.unitorq.com UT-1000 Electro-Pneumatic Positioners Linear & Rotary Unmatched Stability in Tough Environments. UniTorq s advanced-control electro-pneumatic

More information

RF Capacitance Level Controls

RF Capacitance Level Controls CAC-8A-00-6 681R7 Features and Benefits Reliability Low maintenance costs No moving parts Interface measurement with on/off and continuous output Unaffected by changes in pressure, temperature, specific

More information

Global Water Instrumentation, Inc.

Global Water Instrumentation, Inc. Global Water Instrumentation, Inc. 151 Graham Road P.O. Box 9010 College Station, TX 77842-9010 T: 800-876-1172 Int l: (979) 690-5560, Fax: (979) 690-0440 E-mail : globalw@globalw.com Radar Level Transmitters

More information

U Series Non-Contact Ultrasonic Transmitter

U Series Non-Contact Ultrasonic Transmitter U Series Non-Contact Ultrasonic Transmitter Form 1035 This new SOR Ultrasonic Transmitter is a proven solution offering more flexibility and reliability than similar transmitters. With unique features,

More information

GUIDED WAVE RADAR TRANSMITTER

GUIDED WAVE RADAR TRANSMITTER GUIDED WAVE RADAR TRANSMITTER FOR CONTINUOUS LEVEL MEASUREMENT Based on Time Domain Reflectometry (TRD) principle Not affected by density and/or temperature variations Not affected by viscosity, gravity,

More information

Echotel Model 910 Ultrasonic Level Switch

Echotel Model 910 Ultrasonic Level Switch Echotel Model 910 Ultrasonic Level Switch D E S C R I P T I O N Echotel Model 910 Level Switches utilize ultrasonic contact technology for measuring level in clean liquid applications. The dual conduit

More information

Level Transmitter / Controller / Indicator. 3-in-1 package that is simple to install and use. With expanded ranges and improved chemical resistance.

Level Transmitter / Controller / Indicator. 3-in-1 package that is simple to install and use. With expanded ranges and improved chemical resistance. Level Transmitter / Controller / Indicator 3-in-1 package that is simple to install and use. With expanded ranges and improved chemical resistance. 2.1 NEW Class 1, Division 1 Hazardous Areas Approved

More information

KFS. Flap-type flow meter. Design and range of application

KFS. Flap-type flow meter. Design and range of application Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is

More information

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER Configuration Code TM01 Series 642 Programmable HART Field Temperature The Series 642 programmable HART field temperature transmitter is a 2-wire unit with analog output. It includes input for RTDs; resistance

More information

Sultan Acoustic Wave Series

Sultan Acoustic Wave Series A Higher Level of Performance Data Sheet Sultan Acoustic Wave Series Machinery Positioning Systems For more information, please visit > www.hawkmeasure.com Principle of Operation The Sultan for Machinery

More information

IP26 Series Current to Pneumatic Converter

IP26 Series Current to Pneumatic Converter Product Specifications 06.2016 PSS EVE0403 A-(en) IP26 Series Current to Pneumatic Converter The IP26 (current to pressure) transducer converts a 4 20mA electrical current signal to a proportional linear

More information

Mass and Volume Flow Transmitter

Mass and Volume Flow Transmitter IFT9701 Product Data Sheet PS-00218-EU December1999 Mass and Volume Flow Transmitter IFT9701 transmitter The IFT9701 microprocessor-based transmitter works with Micro Motion sensors to provide affordable,

More information

THE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC)

THE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC) THE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC) Part 1. General 1.1 Scope A. This section describes the requirements for an ultrasonic, single-point level controller

More information

Guided Wave Radar Bulk Solids Level Transmitter

Guided Wave Radar Bulk Solids Level Transmitter www.ktekcorp.com Guided Wave Radar Bulk Solids Level Transmitter FEATURES Radar Signal Travels Along the Waveguide Eliminates False Echoes and Minimizes Signal Loss No Moving Parts 2 Wire Loop Powered

More information

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter.   TEMPERATURE. Technology Solutions Technology Solutions TEK-TEMP 2100A Explosion-Proof Temperature Transmitter TEMPERATURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Explosion-Proof

More information

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet Specification Sheet 600T Series Transmitters Model 65L Electronic temperature transmitter (PC programmable for RTD and resistance) High flexibility and wide rangeability Primary element and calibration

More information

The Radar Level Meters can be installed both in metallic or non metallic tanks; their use is not harmful to humans or environment.

The Radar Level Meters can be installed both in metallic or non metallic tanks; their use is not harmful to humans or environment. 1 EIP COMPACT WAVE 26 GHZ CW Series PULSE RADAR LEVEL INSTRUMENTS (26 GHz) DESCRIPTION The Radar Level Meters of EIP COMPACT WAVE 6.3 GHz series are excellent devices for no contact level measurement.

More information

HOW TO SELECT A CONTINUOUS LEVEL SENSOR WHITEPAPER

HOW TO SELECT A CONTINUOUS LEVEL SENSOR WHITEPAPER WHITEPAPER HOW TO SELECT A CONTINUOUS LEVEL SENSOR Using a continuous level sensor to monitor the material level in your storage vessels can help your operation maintain efficiency preventing costly process

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters

More information

MP Series Radar Transmitter Installation & Operation Manual

MP Series Radar Transmitter Installation & Operation Manual IOM MP Series Radar Transmitter Installation & Operation Manual MP Series Radar Transmitter Installation & Operation Manual CONTENTS I. HANDLING AND STORAGE... 1 Inspection and Handling Disposal and Recycling

More information

ABB MEASUREMENT & ANALYTICS. LLT100, LM80 and LM200 Lasers for level now everything is possible

ABB MEASUREMENT & ANALYTICS. LLT100, LM80 and LM200 Lasers for level now everything is possible ABB MEASUREMENT & ANALYTICS LLT100, LM80 and LM200 Lasers for level now everything is possible 2 L LT 1 0 0, L M 8 0 A N D L M 2 0 0 L A S E R S F O R L E V E L N O W E V E R Y T H I N G I S P O S S I

More information

Sitron Capacitive Level Sensors

Sitron Capacitive Level Sensors Sitron Capacitive evel Sensors Models: SC404 SC120CN200 SC400V400 SC700 Introduction Capacitive evel Sensors, also referred to as Radio Frequency (RF) level sensors, are used for measuring process level

More information

process measurement solutions Mobrey MSP IP wire 24V loop powered ultrasonic level transmitters

process measurement solutions Mobrey MSP IP wire 24V loop powered ultrasonic level transmitters process measurement solutions Mobrey MSP 2 wire 24V loop powered ultrasonic level transmitters IP2045 MSP Advanced ultrasonics This new family of ultrasonic non-contacting liquid level transmitters is

More information

KOBOLD EchoKing NEO-5003 Series Ultrasonic Level Transmitter User Instructions KOB

KOBOLD EchoKing NEO-5003 Series Ultrasonic Level Transmitter User Instructions KOB KOBOLD EchoKing NEO-5003 Series Ultrasonic Level Transmitter User Instructions KOB KOBOLD Instruments Inc. 1801 Parkway View Drive Pittsburgh PA 15205 Phone (412) 788-2830 Fax (412)-788-4890 Manual-NEO_5003-4_1-17

More information

Submersible pressure sensor For water and wastewater Model LW-1

Submersible pressure sensor For water and wastewater Model LW-1 Replacement product: Model LF-1 Level measurement Submersible pressure sensor For water and wastewater Model LW-1 WIKA data sheet LM 40.03 Applications Level measurement in rivers and lakes Deep well and

More information

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable) Specification Sheet 600T Series Transmitters Model 65T Electronic temperature transmitter (PC programmable) High flexibility and wide rangeability Single transmitter accepts RTD/THC/mV/ohm Galvanically

More information

Sultan Flow. Data Sheet. Overview. A Higher Level of Performance. Real Time Flow Measurement for Liquids.

Sultan Flow. Data Sheet. Overview. A Higher Level of Performance. Real Time Flow Measurement for Liquids. A Higher Level of Performance Data Sheet Real Time Flow Measurement for Liquids For more information, please click on > www.hawk.com.au Principle of Operation The measurement system operates by transmitting

More information

Sultan Liquid- Acoustic Wave Technology

Sultan Liquid- Acoustic Wave Technology A higher level of performance Data Sheet Sultan Liquid- Acoustic Wave Technology Liquids level and position measurements to 10m (33ft) Principle of Operations The Sultan Liquid series emits a high powered

More information

MicroTREK GUIDED MICROWAVE LEVEL TRANSMITTERS

MicroTREK GUIDED MICROWAVE LEVEL TRANSMITTERS For liquids and solids MicroTREK GUIDED MICROWAVE LEVEL TRANSMITTERS O U R P R O F E S S I O N I S Y O U R L E V E L LEVEL TRANSMITTERS MicroTREK TRANSMITTERS FOR LIQUIDS AND SOLIDS FEATURES Measuring

More information

Alphaline Temperature Transmitters

Alphaline Temperature Transmitters Alphaline Temperature Transmitters Accepts RTD and thermocouple inputs Available with an integral meter Dual compartment housing provides the highest reliability in harsh industrial environments Offers

More information

Technical Specification FLUXUS ADM 8x27

Technical Specification FLUXUS ADM 8x27 Ultrasonic Flow Measurement of Liquids in Explosive Atmosphere Features Transducers non-invasive (no contact with the medium, no need for expensive materials) wearfree no pressure drop (no operational

More information

UTM10 Series Ultrasonic Transit-time Flowmeters

UTM10 Series Ultrasonic Transit-time Flowmeters Ultrasonic Transit-time meters Description UTM10 ultrasonic flow and energy meters clamp onto the outside of pipes and do not make contact with the internal liquid. The technology has inherent advantages

More information

Main features. Operation. LEVEL Transmitters

Main features. Operation. LEVEL Transmitters Non-contact microwave level transmitters pilotr GNRAL DSCRIPTION The 25 GHz (-band) Pulse Radars are regarded as the most progressive non-contact level transmitters of the industrial process automation

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. TB82 2-wire conductivity transmitters

ABB MEASUREMENT & ANALYTICS DATA SHEET. TB82 2-wire conductivity transmitters ABB MEASUREMENT & ANALYTICS DATA SHEET TB8 -wire conductivity transmitters TB 8 -W I R E CON DUCT I VI T Y TR ANSMIT TE RS DS/ TB8 -E N RE V. H Measurement made easy Loop-powered transmitters that reduce

More information

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL WITH DIAPHRAGM SEAL APT3200L Application Areas: Nuclear Water & Wastewater Chemicals Petrochemical Oil & Gas Pulp & Paper Food & Beverage, Pharmaceutical Power Renewable Energy Alternate Fuel Autrol America

More information

2-Wire. Level Gauge BM 702

2-Wire. Level Gauge BM 702 KROHNE 09/2001 7.02323.22.00 GR/PRINTO Level Gauge 2-Wire Level-Radar 2-Wire The first and only FMCW Radar Level Gauge with 2-wire technology The non-contact alternative to ageing technologies Maintenance-free

More information

ECHOTEL 961/962. Ultrasonic level switches. Loop or line powered D E S C R I P T I O N F E AT U R E S A G E N C Y A P P R O VA L S

ECHOTEL 961/962. Ultrasonic level switches. Loop or line powered D E S C R I P T I O N F E AT U R E S A G E N C Y A P P R O VA L S ECHOTEL 961/962 Ultrasonic level switches D E S C R I P T I O N The Echotel 961/962 series utilizes pulse signal technology to detect high or low level alarm(s) in a broad range of viscous to light liquids.

More information

Basics of continuous level measurements. By Gene Henry, Level Product Marketing Manager, Endress+Hauser. d = c 2

Basics of continuous level measurements. By Gene Henry, Level Product Marketing Manager, Endress+Hauser. d = c 2 Basics of continuous level measurements By Gene Henry, Level Product Marketing Manager, Endress+Hauser The most common technologies available for continuous level measurement are ultrasonic, free space

More information

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5. Ex i Isolators Temperature Transmitter with Output 0/4... 20 ma, without Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe

More information

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 DOC. NO. : C3200-E04A FM APPROVED Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200 APT3200 Smart Pressure Transmitter Standard SST Housing Description of Product The

More information

Proven Measurement for A World of Applications

Proven Measurement for A World of Applications Proven Measurement for A World of Applications Building on Experience. Niagara Meters is a flow meter company representing a complete line of flow meters manufactured by Venture Measurement Co., LLC in

More information