1 Basic Instrumentation Joachim Mueller Principles of Fluorescence Spectroscopy Genova, Italy June 30 July 3, 2008 Figure and slide acknowledgements: Theodore Hazlett Fluorometer ISS PC1 (ISS Inc., Champaign, IL, USA) Fluorolog-3 (Jobin Yvon Inc, Edison, NJ, USA ) QuantaMaster (OBB Sales, London, Ontario N6E 2S8) Fluorometer Components Excitation Polarizer Sample Light Source Excitation Wavelength Selection Computer Emission Polarizer Emission Wavelength Selection Detector Fluorometer: The Basics Note: Both polarizers can be removed from the optical beam path 1
2 Fluorometer Components Light Source Detectors Wavelength Selection Polarizers The Laboratory Fluorometer Standard Light Source: Xenon Arc Lamp Exit Slit P ex P em P em ISS (Champaign, IL, USA) PC1 Fluorometer Light Sources 2
3 Lamp Light Sources: Arc Lamps 1. Xenon Arc Lamp (wide range of wavelengths) Lamp Profiles: Ozone Free UV Visible 15 kw Xenon arc lamp 2. High Pressure Mercury Lamps (High Intensities but concentrated in specific lines) Lamp Light Sources: Arc Lamps 3. Mercury-Xenon Arc Lamp (greater intensities in the UV) ARC LAMP ISSUES: Limited Lifetime Stability (flicker + drifts) Safety high internal gas pressures hot never stare into burning lamp do not touch with bare hands LAMP HOUSING + OPTICS : Conventional OR Compact Cermax lamp Lamp Light Sources: Incandescent 4. Tungsten-Halogen Lamps A Tungsten-Halogen lamp with a filter to remove UV light. The color temperature varies with the applied voltage (average values range from about 2200 K to 3400 K). 3
4 Lamp Light Sources: Semiconductor 5. Light Emitting Diodes (LEDs) Spectra for blue, yellow-green, and red LEDs. FWHM spectral bandwidth is approximately 25 nm for all three colors. White LED: typical emission spectrum Lamp Luminous Flux (Lumens) Spectral Irradiance (Milliwatt/Square Meter/Nanometer) HBO 100 Watts ( nm) XBO 75 Watts ( nm) Tungsten 100 Watts 2800 < 1 ( nm) Superbright LED LED (Blue, 450 nm) Lamp Light Sources: Semiconductor 5. Light Emitting Diodes (LEDs) Wavelengths from 260 nm to 2400 nm Deep UV LEDs λ 260 nm Laser Light Sources Argon Ion: Wavelength Rel Pwr Wavelength Rel Pwr Wavelength 528.7nm nm nm 514.5nm nm nm 501.7nm nm nm 496.5nm nm nm nm nm 295nm 266nm 325nm Doubled Ti:Sapphire 350 nm 500 nm 355nm 351 nm 364 nm 442nm 514nm 488nm 528nm 532nm 633nm 543nm 612nm 594nm Ti:Sapphire 690 nm 1050 nm Argon-ion 100 mw Helium-cadmium Nd-YAG He-Ne Red 633nm >10 mw Orange 612nm 10mW Yellow 594nm 4mW Green 543nm 3mW 4
5 Laser Diodes (DPSS) Diode pumped solid state laser Wavelengths (nm): 262, 266, 349, 351, 355, 375, 405, 415, 430, 440, 447, 473, 488, 523, 527, 532, 542, 555, 561, , 638, 655, 658, 671, 685, 785, 808, 852, 946, 980, 1047, 1053, 1064, 1080, , 1444, 1550 Supercontinuum Light Focus ultrashort pulsed light into photonic crystal fiber Photonic crystal fiber Detectors 5
6 Photon Multiplier Tube Microchannel Plate Detector (MCP) MCP & Electronics (ISS Inc. Champaign, IL USA) For fast modulation f > 500 MHz The Classic PMT Design Photocathode Vacuum Dynodes λ e - e - e - e - e - e - e - e - - e - - e - e - Anode Window Constant Voltage (use of a Zenor Diode) Current Output High Voltage Supply (-1000 to V) resister series (voltage divider) capacitor series (current source) Ground Hamamatsu R928 PMT Family R2949 Window with Photocathode Beneath 6
7 PMT Quantum Efficiencies Cathode Material Window Material Photon Counting (Digital) and Analog Detection time Signal Continuous Current Measurement Photon Counting: Constant High Voltage Supply PMT Analog: Variable Voltage Supply PMT Discriminator Sets Level level TTL Output (1 photon = 1 pulse) Anode Current = Pulse averaging Computer Primary Advantages: 1. Sensitivity (high signal/noise) 2. Increased measurement stability Primary Advantage: 1. Broad dynamic range 2. Adjustable range Side-On PMT PMT Geometries Head-On PMT Opaque photocathode Semitransparent Photocathode Side-on PMTs have slightly enhanced quantum efficiency over Head-on PMTs Side-on PMTs often have larger afterpulsing probabilities than Head-on PMTs Side-on PMTs count rate linearity less than for Head-on PMT Head-on PMTs provide better spatial uniformity than Side-on PMTs Side-on PMTs have faster response time than Head-on PMTs (compact design) Side-on PMTs are less affected by a magnetic field than Head-on PMTs 7
8 Avalanche Photodiode (APD) APD for analog detection APD for photon counting The silicon avalanche photodiode (Si APD) has a fast time response and high sensitivity in the near infrared region. APDs are available with active areas from 0.2 mm to 5.0 mm in diameter and low dark currents (selectable). Photo courtesy of Hamamatsu Single photon counting module (SPCM) from Perkin-Elmer Wavelength Selection Fixed Optical Filters Tunable Optical Filters Monochromators Optical Filter Channel P ex P em P em 8
9 Long Pass Optical Filters 100 Transmission (%) Spectral Shape Thickness Physical Shape Fluorescence (!?) Hoya O54 More Optical Filter Types 100 Broad Bandpass Filter (Hoya U330) Interference Filters (Chroma Technologies) 80 Transmission (%) Neutral Density (Coherent Lasers) Tunable Optical Filters Liquid Crystal Filters: An electrically controlled liquid crystal elements to select a specific visible wavelength of light for transmission through the filter at the exclusion of all others. AO Tunable Filters: The AOTF range of acousto-optic devices are solid state optical filters. The wavelength of the diffracted light is selected according to the frequency of the RF drive signal. 9
10 Monochromators Mirrors Czerny-Turner design 1. Slit Width (mm) is the dimension of the slits. Exit Slit 2. Bandpass is the FWHM of the selected wavelength. 3. The dispersion is the factor to convert slit width to bandpass. Entrance slit Rotating Diffraction Grating (Planar or Concaved) The Inside of a Monochromator Mirrors Grating Nth Order (spectral distribution) Zero Order (acts like a mirror) Order of diffraction 1-st order 0-th order (acts like a mirror) 2-nd order 10
11 Changing the Bandpass 1. Drop in intensity 2. Narrowing of the spectral selection Fixed Excitation Bandpass = 4.25 nm Changing the Emission Bandpass nm 8.5 nm 4.25 nm nm Fluorescence x10 6 (au) nm 8.5 nm 4.25 nm nm Collected on a SPEX Fluoromax - 2 Higher Order Light Diffraction Emission Scan: Excitation 300 nm Glycogen in PBS Fluorescence x10 3 (au) Excitation (Rayleigh) Scatter (300 nm) Water RAMAN (334 nm) 2 nd Order Scatter (600 nm) 2 nd Order RAMAN (668 nm) Fluorescent Contaminants Raman scatter of water Vibrational modes of water Resonant Stokes Raman scattering Energy for the OH stretch vibrational mode in water (expressed in inverse wavenumbers): 3400 cm -1 Simple formula to calculate the wavelength of the Raman peak: 7 (1) Take the excitation wavelength (say 10 = nm) and insert in the following equation: 490 (2) The result specifies the position of the raman peak in nanometers (i.e. the raman peak is at 587nm for an excitation wavelength of 490nm. 11
12 Monochromator Polarization Bias Tungsten Lamp Profile Collected on an SLM Fluorometer Wood s Anomaly Parallel Emission No Polarizer Fluorescence Fluorescence Perpendicular Emission Adapted from Jameson, D.M., Instrumental Refinements in Fluorescence Spectroscopy: Applications to Protein Systems., in Biochemistry, Champaign-Urbana, University of Illinois, Correction of Emission Spectra ISSPC1 Correction Factors vertical horizontal (nm) Wavelength ANS Emission Spectrum, no polarizer ANS Emission Spectrum, parallel polarizer Fluorescence Intensity (a.u.) B Fluorescence Intensity (a.u.) C uncorrected corrected Wavelength Wavelength from Jameson et. Al., Methods in Enzymology, 360:1 Excitation Correction Quantum Counter Exit Slit P ex P em P em 12
13 The Instrument Quantum Counter Common Quantum Counters (optimal range)* Rhodamine B Fluorescein Quinine Sulfate ( nm) ( nm) ( nm) Quantum Counter Optical Filter Eppley Thermopile/ QC Linearity of Rhodamine as a quantum counter Fluorescence Here we want the inner filter effect! Reference Detector * Melhuish (1962) J. Opt. Soc. Amer. 52:1256 Excitation Correction Absorption (dotted line) and Excitation Spectra (solid line) of ANS in Ethanol Fluorescence Uncorrected A Fluorescence B Ratio Corrected (nm) Wavelength 1.0 Fluorescence Lamp Corrected C (nm) Wavelength (nm) Wavelength from Jameson et. Al., Methods in Enzymology, 360:1 Polarizers Common Types: Glan Taylor (air gap) Glan Thompson Sheet Polarizers The Glan Taylor prism polarizer 0 Two Calcite Prisms 90 0 Sheet polarizer 90 Two UV selected calcite prisms are assembled with an intervening air space. The calcite prism is birefringent and cut so that only one polarization component continues straight through the prisms. The spectral range of this polarizer is from 250 to 2300 nm. At 250 nm there is approximately 50% transmittance. 13
14 Sample Issues Signal Attenuation of the Excitation Light PMT Saturation Excess Emission Fluorescence vs Signal Instrument Signal LINEAR REGION x x10 6 [Fluorophore] Reduced emission intensity 1. ND Filters 2. Narrow slit widths 3. Move off absorbance peak Attenuation of the Excitation Light through Absorbance Sample concentration & the inner filter effect Rhodamine B from Jameson et. al., Methods in Enzymology (2002), 360:1 The second half of the inner filter effect: attenuation of the emission signal Diluted Sample 4 3 x x x Absorbance Spectrum (1) Spectral Shift (2) Change in Spectral Shape 14
15 How do we handle highly absorbing solutions? Quartz/Optical Glass/Plastic Cells Excitation Emission Path Length Emission Detector 4 Position Turret SPEX Fluoromax-2, Jobin-Yvon Excitation Path Length Front Face Detection Triangular Cells Thin Cells & Special Compartments Excitation IBH, Glasgow G3 8JU United Kingdom Emission Mirror Excitation Detector Sample [1] Reflected Excitation & Emission Absorbance Measurements [1] Adapted from Gryczynski, Lubkowski, & Bucci Methods of Enz. 278: 538 Lifetime Instrumentation 15
16 Light Sources for Decay Acquisition: Frequency and Time Domain Measurements Pulsed Light Sources (frequency & pulse widths) Mode-Locked Lasers ND:YAG (76 MHz) (150 ps) Pumped Dye Lasers (4 MHz Cavity Dumped, ps) Ti:Sapphire lasers (80 MHz, 150 fs) Mode-locked Argon Ion lasers Directly Modulated Light Sources Diode Lasers (short pulses in ps range, & can be modulated by synthesizer) LEDs (directly modulated via synthesizer, 1 ns, 20 MHz) Flash Lamps Thyratron-gated nanosecond flash lamp (PTI), 25 KHz, 1.6 ns Coaxial nanosecond flashlamp (IBH), 10Hz-100kHz, 0.6 ns Modulation of CW Light Use of a Pockel s Cell Pulsed Emission 0 Polished on a side exit plane Pockel s Cell Polarizer Mirror Double Pass Pockel s Cell Polarizer Radio Frequency Input 90 CW Light Source The Pockel s Cell is an electro-optic device that uses the birefringment properties of calcite crystals to alter the beam path of polarized light. In applying power, the index of refraction is changed and the beam exiting the side emission port (0 polarized) is enhanced or attenuated. In applying RF the output becomes modulated. Time Correlated Single Photon Counting Timing Electronics or 2 nd PMT Pulsed Light Source Sample Compartment Filter or Monochromator Neutral density (reduce to one photon/pulse) Constant Fraction Discriminator Time-to-Amplitude Converter (TAC) Counts TAC Multichannel Analyzer Time PMT Photon Counting PMT Instrument Considerations Excitation pulse width Excitation pulse frequency Timing accuracy Detector response time (PMTs ns; MCP 0.15 to 0.03 ns) 16
17 Histograms built one photon count at a time Fluorescence Decay 2 Fluorescence Instrument Response Function Channels (50 ps) (1) The pulse width and instrument response times determine the time resolution. (2) The pulse frequency also influences the time window. An 80 MHz pulse frequency (Ti:Sapphire laser) would deliver a pulse every 12.5 ns and the pulses would interfere with photons arriving later than the 12.5 ns time. Polarization Correction There is still a polarization problem in the geometry of our excitation and collection (even without a monochromator)!! Will the corrections never end??? An intuitive argument: [6] [4] [1] = I 0 + I 90 [2] = I 0 + I 90 [3] = I 0 + I 90 [4] = I 0 + I 90 0 Polarized Excitation [1] [3] [5] = 2 x I 90 [6] = 2 x I 90 Total = 4 x I x I 90 [2] 0 [5] The total Intensity is proportional to: I x I Setting the excitation angle to 0 and the emission polarizer to 54.7 the proper weighting of the vectors is achieved.* *Spencer & Weber (1970) J. Chem Phys. 52:1654 Frequency Domain Fluorometry Pockel s Cell CW Light Source Sample Compartment Filter or Monochromator RF PMT PMT Analog PMTs (can also be done with photon counting) Synthesizers S1 and S2 S1 = n MHz S1 Reference Turret RF S2 Signal Locking Signal Signal Digital Acquisition Electronics S2 = n MHz Hz Computer Driven Controls Similar instrument considerations as With TCSPC 17
18 Lifetime Station #3, LDF, Champaign IL, USA 18
David Jameson 3/23/2015
Principles of Fluorescence Techniques 2015 Urbana-Champaign, Illinois April 6-9, 2015 Basic Instrumentation: David Jameson (some of these slides were prepared by Theodore Chip Hazlett and Joachim Müller)
More informationPrinciples of Fluorescence Techniques 2014 Urbana-Champaign, Illinois April 7-10, 2014
Principles of Fluorescence Techniques 2014 Urbana-Champaign, Illinois April 7-10, 2014 Basic Instrumentation: David Jameson (some of these slides were prepared by Theodore Chip Hazlett and Joachim Müller)
More informationThe Weber Conference on Advanced Fluorescence Microscopy Techniques December 12-17, 2011 Buenos Aires
The Weber Conference on Advanced Fluorescence Microscopy Techniques December 12-17, 2011 Buenos Aires Basic Instrumentation: David Jameson (many of these slides were prepared by Theodore Chip Hazlett and
More informationDavid Jameson 4/4/2018
Principles of Fluorescence Techniques 2016 Urbana-Champaign, Illinois April 3-6, 2018 Basic Fluorescence Principles IV: David Jameson Basic Instrumentation (some of these slides were prepared by Theodore
More informationBasic e Instrumentation
1 Basic e Instrumentation Martin vandeven Principles of Fluorescence Techniques 2010 Madrid, Spain May 31 June 04, 2010 Slide acknowledgements Dr. Theodore Hazlett, Dr. Joachim Müller 1 Fluorometers 2
More informationPrinciples of Fluorescence Techniques 2008 Chicago April 9-11, 2008
Principles of Fluorescence Techniques 2008 Chicago April 9-11, 2008 Basic Instrumentation David Jameson (many of these slides were prepared by Theodore Chip Hazlett and Joachim Mueller) The Basics Wavelength
More informationChemistry 524--"Hour Exam"--Keiderling Mar. 19, pm SES
Chemistry 524--"Hour Exam"--Keiderling Mar. 19, 2013 -- 2-4 pm -- 170 SES Please answer all questions in the answer book provided. Calculators, rulers, pens and pencils permitted. No open books allowed.
More informationSpectroscopy in the UV and Visible: Instrumentation. Spectroscopy in the UV and Visible: Instrumentation
Spectroscopy in the UV and Visible: Instrumentation Typical UV-VIS instrument 1 Source - Disperser Sample (Blank) Detector Readout Monitor the relative response of the sample signal to the blank Transmittance
More informationSpectrophotometer. An instrument used to make absorbance, transmittance or emission measurements is known as a spectrophotometer :
Spectrophotometer An instrument used to make absorbance, transmittance or emission measurements is known as a spectrophotometer : Spectrophotometer components Excitation sources Deuterium Lamp Tungsten
More informationSCCH 4: 211: 2015 SCCH
SCCH 211: Analytical Chemistry I Analytical Techniques Based on Optical Spectroscopy Atitaya Siripinyanond Office Room: C218B Email: atitaya.sir@mahidol.ac.th Course Details October 19 November 30 Topic
More informationcombustion diagnostics
3. Instrumentation t ti for optical combustion diagnostics Equipment for combustion laser diagnostics 1) Laser/Laser system 2) Optics Lenses Polarizer Filters Mirrors Etc. 3) Detector CCD-camera Spectrometer
More informationApplications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region
Feature Article JY Division I nformation Optical Spectroscopy Applications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region Raymond Pini, Salvatore Atzeni Abstract Multichannel
More informationComponents of Optical Instruments. Chapter 7_III UV, Visible and IR Instruments
Components of Optical Instruments Chapter 7_III UV, Visible and IR Instruments 1 Grating Monochromators Principle of operation: Diffraction Diffraction sources: grooves on a reflecting surface Fabrication:
More informationComponents of Optical Instruments
Components of Optical Instruments General Design of Optical Instruments Sources of Radiation Wavelength Selectors (Filters, Monochromators, Interferometers) Sample Containers Radiation Transducers (Detectors)
More informationCONFIGURING. Your Spectroscopy System For PEAK PERFORMANCE. A guide to selecting the best Spectrometers, Sources, and Detectors for your application
CONFIGURING Your Spectroscopy System For PEAK PERFORMANCE A guide to selecting the best Spectrometers, s, and s for your application Spectral Measurement System Spectral Measurement System Spectrograph
More informationOPTI510R: Photonics. Khanh Kieu College of Optical Sciences, University of Arizona Meinel building R.626
OPTI510R: Photonics Khanh Kieu College of Optical Sciences, University of Arizona kkieu@optics.arizona.edu Meinel building R.626 Photodetectors Introduction Most important characteristics Photodetector
More informationVertical External Cavity Surface Emitting Laser
Chapter 4 Optical-pumped Vertical External Cavity Surface Emitting Laser The booming laser techniques named VECSEL combine the flexibility of semiconductor band structure and advantages of solid-state
More informationContinuum White Light Generation. WhiteLase: High Power Ultrabroadband
Continuum White Light Generation WhiteLase: High Power Ultrabroadband Light Sources Technology Ultrafast Pulses + Fiber Laser + Non-linear PCF = Spectral broadening from 400nm to 2500nm Ultrafast Fiber
More informationLecture 5: Introduction to Lasers
Lecture 5: Introduction to Lasers http://en.wikipedia.org/wiki/laser History of the Laser v Invented in 1958 by Charles Townes (Nobel prize in Physics 1964) and Arthur Schawlow of Bell Laboratories v Was
More informationDETECTORS Important characteristics: 1) Wavelength response 2) Quantum response how light is detected 3) Sensitivity 4) Frequency of response
DETECTORS Important characteristics: 1) Wavelength response 2) Quantum response how light is detected 3) Sensitivity 4) Frequency of response (response time) 5) Stability 6) Cost 7) convenience Photoelectric
More informationComponents of Optical Instruments 1
Components of Optical Instruments 1 Optical phenomena used for spectroscopic methods: (1) absorption (2) fluorescence (3) phosphorescence (4) scattering (5) emission (6) chemiluminescence Spectroscopic
More informationNd: YAG Laser Energy Levels 4 level laser Optical transitions from Ground to many upper levels Strong absorber in the yellow range None radiative to
Nd: YAG Lasers Dope Neodynmium (Nd) into material (~1%) Most common Yttrium Aluminum Garnet - YAG: Y 3 Al 5 O 12 Hard brittle but good heat flow for cooling Next common is Yttrium Lithium Fluoride: YLF
More informationThe equipment used share any common features regardless of the! being measured. Electronic detection was not always available.
The equipment used share any common features regardless of the! being measured. Each will have a light source sample cell! selector We ll now look at various equipment types. Electronic detection was not
More informationCOMPONENTS OF OPTICAL INSTRUMENTS. Chapter 7 UV, Visible and IR Instruments
COMPONENTS OF OPTICAL INSTRUMENTS Chapter 7 UV, Visible and IR Instruments 1 Topics A. GENERAL DESIGNS B. SOURCES C. WAVELENGTH SELECTORS D. SAMPLE CONTAINERS E. RADIATION TRANSDUCERS F. SIGNAL PROCESSORS
More informationCOMPONENTS OF OPTICAL INSTRUMENTS. Topics
COMPONENTS OF OPTICAL INSTRUMENTS Chapter 7 UV, Visible and IR Instruments Topics A. GENERAL DESIGNS B. SOURCES C. WAVELENGTH SELECTORS D. SAMPLE CONTAINERS E. RADIATION TRANSDUCERS F. SIGNAL PROCESSORS
More informationCHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES
CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES The current multiplication mechanism offered by dynodes makes photomultiplier tubes ideal for low-light-level measurement. As explained earlier, there
More informationWhy and How? Daniel Gitler Dept. of Physiology Ben-Gurion University of the Negev. Microscopy course, Michmoret Dec 2005
Why and How? Daniel Gitler Dept. of Physiology Ben-Gurion University of the Negev Why use confocal microscopy? Principles of the laser scanning confocal microscope. Image resolution. Manipulating the
More informationFluorolog and Fluorocube for Picosecond Molecular Dynamics. Lifetime Systems from HORIBA Jobin Yvon. Frequency Domain or Time Domain? Why Lifetimes?
Fluorolog and for Picosecond Molecular Dynamics Time is always on your side with a lifetime system from HORIBA Jobin Yvon. Drawing on the expertise of Spex, SLM, and IBH, we ve put together solutions that
More informationPGx11 series. Transform Limited Broadly Tunable Picosecond OPA APPLICATIONS. Available models
PGx1 PGx3 PGx11 PT2 Transform Limited Broadly Tunable Picosecond OPA optical parametric devices employ advanced design concepts in order to produce broadly tunable picosecond pulses with nearly Fourier-transform
More informationUV-VIS-IR Spectral Responsivity Measurement System for Solar Cells
November 1998 NREL/CP-52-25654 UV-VIS-IR Spectral Responsivity Measurement System for Solar Cells H. Field Presented at the National Center for Photovoltaics Program Review Meeting, September 8 11, 1998,
More informationBASICS OF CONFOCAL IMAGING (PART I)
BASICS OF CONFOCAL IMAGING (PART I) INTERNAL COURSE 2012 LIGHT MICROSCOPY Lateral resolution Transmission Fluorescence d min 1.22 NA obj NA cond 0 0 rairy 0.61 NAobj Ernst Abbe Lord Rayleigh Depth of field
More informationDual-FL. World's Fastest Fluorometer. Measure absorbance spectra and fluorescence simultaneously FLUORESCENCE
Dual-FL World's Fastest Fluorometer Measure absorbance spectra and fluorescence simultaneously FLUORESCENCE 100 Times Faster Data Collection The only simultaneous absorbance and fluorescence system available
More informationVELA PHOTOINJECTOR LASER. E.W. Snedden, Lasers and Diagnostics Group
VELA PHOTOINJECTOR LASER E.W. Snedden, Lasers and Diagnostics Group Contents Introduction PI laser step-by-step: Ti:Sapphire oscillator Regenerative amplifier Single-pass amplifier Frequency mixing Emphasis
More informationSpectroscopy of Ruby Fluorescence Physics Advanced Physics Lab - Summer 2018 Don Heiman, Northeastern University, 1/12/2018
1 Spectroscopy of Ruby Fluorescence Physics 3600 - Advanced Physics Lab - Summer 2018 Don Heiman, Northeastern University, 1/12/2018 I. INTRODUCTION The laser was invented in May 1960 by Theodor Maiman.
More informationThe only simultaneous absorbance and f uorescence system for water quality analysis! Aqualog
The only simultaneous absorbance and fluorescence system for water quality analysis! Aqualog CDOM measurements made easy. The only simultaneous absorbance and fluorescence system for water quality analysis!
More informationChemistry Instrumental Analysis Lecture 7. Chem 4631
Chemistry 4631 Instrumental Analysis Lecture 7 UV to IR Components of Optical Basic components of spectroscopic instruments: stable source of radiant energy transparent container to hold sample device
More informationAqualog. Water Quality Measurements Made Easy FLUORESCENCE
Aqualog Water Quality Measurements Made Easy FLUORESCENCE Water quality measurements made easy The only simultaneous absorbance and fluorescence system for water quality analysis! The new Aqualog is the
More informationAqualog. CDOM Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN
Aqualog CDOM Measurements Made Easy ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS PARTICLE CHARACTERIZATION RAMAN SPECTROSCOPIC ELLIPSOMETRY SPR IMAGING CDOM measurements
More informationA new picosecond Laser pulse generation method.
PULSE GATING : A new picosecond Laser pulse generation method. Picosecond lasers can be found in many fields of applications from research to industry. These lasers are very common in bio-photonics, non-linear
More informationMASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Electrical Engineering and Computer Science
Student Name Date MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Electrical Engineering and Computer Science 6.161 Modern Optics Project Laboratory Laboratory Exercise No. 6 Fall 2010 Solid-State
More informationUltraviolet Visible Infrared Instrumentation
Ultraviolet Visible Infrared Instrumentation Focus our attention on measurements in the UV-vis region of the EM spectrum Good instrumentation available Very widely used techniques Longstanding and proven
More informationCONTENTS. Chapter 1 Wave Nature of Light 19
CONTENTS Chapter 1 Wave Nature of Light 19 1.1 Light Waves in a Homogeneous Medium 19 A. Plane Electromagnetic Wave 19 B. Maxwell's Wave Equation and Diverging Waves 22 Example 1.1.1 A diverging laser
More informationPCS-150 / PCI-200 High Speed Boxcar Modules
Becker & Hickl GmbH Kolonnenstr. 29 10829 Berlin Tel. 030 / 787 56 32 Fax. 030 / 787 57 34 email: info@becker-hickl.de http://www.becker-hickl.de PCSAPP.DOC PCS-150 / PCI-200 High Speed Boxcar Modules
More informationPITZ Laser Systems. Light Amplification by Stimulated Emission of Radiation. Cavity. What is a Laser? General introduction: systems, layouts
PITZ Laser Systems General introduction: systems, layouts Matthias Groß PITZ Laser Systems Technisches Seminar Zeuthen, 14.11.2017 What is a Laser? > General setup Light Amplification by Stimulated Emission
More informationOptics and Lasers. Matt Young. Including Fibers and Optical Waveguides
Matt Young Optics and Lasers Including Fibers and Optical Waveguides Fourth Revised Edition With 188 Figures Springer-Verlag Berlin Heidelberg New York London Paris Tokyo Hong Kong Barcelona Budapest Contents
More informationWill contain image distance after raytrace Will contain image height after raytrace
Name: LASR 51 Final Exam May 29, 2002 Answer all questions. Module numbers are for guidance, some material is from class handouts. Exam ends at 8:20 pm. Ynu Raytracing The first questions refer to the
More informationAqualog. Water Quality Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE
Aqualog Water Quality Measurements Made Easy ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS PARTICLE CHARACTERIZATION RAMAN SPECTROSCOPIC ELLIPSOMETRY SPR IMAGING Water
More informationDevelopment of a spectrometry system Using lock-in amplification technique
VNU. JOURNAL OF SCIENCE, Mathematics - Physics, T.xXI, n 0 2, 2005 Development of a spectrometry system Using lock-in amplification technique Department of Physics, College of Science, VNU Abstract. Raman
More informationChapter 14. Tunable Dye Lasers. Presented by. Mokter Mahmud Chowdhury ID no.:
Chapter 14 Tunable Dye Lasers Presented by Mokter Mahmud Chowdhury ID no.:0412062246 1 Tunable Dye Lasers: - In a dye laser the active lasing medium is an organic dye dissolved in a solvent such as alcohol.
More informationCHAPTER 7. Components of Optical Instruments
CHAPTER 7 Components of Optical Instruments From: Principles of Instrumental Analysis, 6 th Edition, Holler, Skoog and Crouch. CMY 383 Dr Tim Laurens NB Optical in this case refers not only to the visible
More informationAkinori Mitani and Geoff Weiner BGGN 266 Spring 2013 Non-linear optics final report. Introduction and Background
Akinori Mitani and Geoff Weiner BGGN 266 Spring 2013 Non-linear optics final report Introduction and Background Two-photon microscopy is a type of fluorescence microscopy using two-photon excitation. It
More informationtaccor Optional features Overview Turn-key GHz femtosecond laser
taccor Turn-key GHz femtosecond laser Self-locking and maintaining Stable and robust True hands off turn-key system Wavelength tunable Integrated pump laser Overview The taccor is a unique turn-key femtosecond
More informationWhere m is an integer (+ or -) Thus light will be spread out in colours at different angles
Diffraction Gratings Recall diffraction gratings are periodic multiple slit devices Consider a diffraction grating: periodic distance a between slits Plane wave light hitting a diffraction grating at angle
More informationimproved stability (compared with
Picosecond Tunable Systems Nanosecond Lasers NT230 SERIES NT230 series lasers deliver high up to 10 mj energy pulses at 100 Hz pulse repetition rate, tunable over a broad spectral range. Integrated into
More information880 Quantum Electronics Optional Lab Construct A Pulsed Dye Laser
880 Quantum Electronics Optional Lab Construct A Pulsed Dye Laser The goal of this lab is to give you experience aligning a laser and getting it to lase more-or-less from scratch. There is no write-up
More informationC1587 UNIVERSAL STREAK CAMERA Selectable features to suit a variety of applications from the vacuum ultraviolet through the near infrared.
C1587 UNIVERSAL STREAK CAMERA Selectable features to suit a variety of applications from the vacuum ultraviolet through the near infrared. HAMAMATSU 1.515 t,5!l 1.525 1.5» UftVCLCMCTH (RICIOKTCO A Measurement
More informationCharacteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy
Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy Qiyuan Song (M2) and Aoi Nakamura (B4) Abstracts: We theoretically and experimentally
More informationWorking in Visible NHMFL
Working in Visible Optics @ NHMFL NHMFL Summer School 05-19-2016 Stephen McGill Optical Energy Range Energy of Optical Spectroscopy Range SCM3 Optics Facility Energy Range of Optical Spectroscopy SCM3
More informationOptical Fibers p. 1 Basic Concepts p. 1 Step-Index Fibers p. 2 Graded-Index Fibers p. 4 Design and Fabrication p. 6 Silica Fibers p.
Preface p. xiii Optical Fibers p. 1 Basic Concepts p. 1 Step-Index Fibers p. 2 Graded-Index Fibers p. 4 Design and Fabrication p. 6 Silica Fibers p. 6 Plastic Optical Fibers p. 9 Microstructure Optical
More informationFS5. Spectrofluorometer. from Single Photons to a Multitude of Measurements
FS5 Spectrofluorometer from Single Photons to a Multitude of Measurements FS5 An unprecedented, modern spectrofluorometer, developed and manufactured by Edinburgh Instruments in the UK Edinburgh Instruments'
More informationExperimental Analysis of Luminescence in Printed Materials
Experimental Analysis of Luminescence in Printed Materials A. D. McGrath, S. M. Vaezi-Nejad Abstract - This paper is based on a printing industry research project nearing completion [1]. While luminescent
More informationScintillation Counters
PHY311/312 Detectors for Nuclear and Particle Physics Dr. C.N. Booth Scintillation Counters Unlike many other particle detectors, which exploit the ionisation produced by the passage of a charged particle,
More informationInstruction manual and data sheet ipca h
1/15 instruction manual ipca-21-05-1000-800-h Instruction manual and data sheet ipca-21-05-1000-800-h Broad area interdigital photoconductive THz antenna with microlens array and hyperhemispherical silicon
More informationR. J. Jones Optical Sciences OPTI 511L Fall 2017
R. J. Jones Optical Sciences OPTI 511L Fall 2017 Semiconductor Lasers (2 weeks) Semiconductor (diode) lasers are by far the most widely used lasers today. Their small size and properties of the light output
More informationTest 1: Example #2. Paul Avery PHY 3400 Feb. 15, Note: * indicates the correct answer.
Test 1: Example #2 Paul Avery PHY 3400 Feb. 15, 1999 Note: * indicates the correct answer. 1. A red shirt illuminated with yellow light will appear (a) orange (b) green (c) blue (d) yellow * (e) red 2.
More informationCharacterizing a single photon detector
Michigan Technological University Digital Commons @ Michigan Tech Dissertations, Master's Theses and Master's Reports - Open Dissertations, Master's Theses and Master's Reports 2011 Characterizing a single
More informationBasics of confocal imaging (part I)
Basics of confocal imaging (part I) Swiss Institute of Technology (EPFL) Faculty of Life Sciences Head of BIOIMAGING AND OPTICS BIOP arne.seitz@epfl.ch Lateral resolution BioImaging &Optics Platform Light
More informationLecture 08. Fundamentals of Lidar Remote Sensing (6)
Lecture 08. Fundamentals of Lidar Remote Sensing (6) Basic Lidar Architecture q Basic Lidar Architecture q Configurations vs. Arrangements q Transceiver with HOE q A real example: STAR Na Doppler Lidar
More informationSupplementary Information for
Supplementary Information for Vibrational Coherence in the Excited State Dynamics of Cr(acac) 3 : Identifying the Reaction Coordinate for Ultrafast Intersystem Crossing Joel N. Schrauben, Kevin L. Dillman,
More informationFS5. Spectrofluorometer. from Single Photons to a Multitude of Measurements
FS5 Spectrofluorometer from Single Photons to a Multitude of Measurements FS5 An unprecedented, modern spectrofluorometer, developed and manufactured by Edinburgh Instruments in the UK Edinburgh Instruments'
More informationUniversity of Wisconsin Chemistry 524 Spectroscopic Components *
University of Wisconsin Chemistry 524 Spectroscopic Components * In journal articles, presentations, and textbooks, chemical instruments are often represented as block diagrams. These block diagrams highlight
More informationDetectors for microscopy - CCDs, APDs and PMTs. Antonia Göhler. Nov 2014
Detectors for microscopy - CCDs, APDs and PMTs Antonia Göhler Nov 2014 Detectors/Sensors in general are devices that detect events or changes in quantities (intensities) and provide a corresponding output,
More informationObservational Astronomy
Observational Astronomy Instruments The telescope- instruments combination forms a tightly coupled system: Telescope = collecting photons and forming an image Instruments = registering and analyzing the
More informationSupplemental Information
Optically Activated Delayed Fluorescence Blake C. Fleischer, Jeffrey T. Petty, Jung-Cheng Hsiang, Robert M. Dickson, * School of Chemistry & Biochemistry and Petit Institute for Bioengineering and Bioscience,
More informationevent physics experiments
Comparison between large area PMTs at cryogenic temperature for neutrino and rare Andrea Falcone University of Pavia INFN Pavia event physics experiments Rare event physics experiment Various detectors
More information5. Scintillation counters
5. Scintillation counters to detect radiation by means of scintillation is among oldest methods of particle detection historical example: particle impinging on ZnS screen -> emission of light flash principle
More informationIntroduction Fundamentals of laser Types of lasers Semiconductor lasers
ECE 5368 Introduction Fundamentals of laser Types of lasers Semiconductor lasers Introduction Fundamentals of laser Types of lasers Semiconductor lasers How many types of lasers? Many many depending on
More informationRecent Development and Study of Silicon Solid State Photomultiplier (MRS Avalanche Photodetector)
Recent Development and Study of Silicon Solid State Photomultiplier (MRS Avalanche Photodetector) Valeri Saveliev University of Obninsk, Russia Vienna Conference on Instrumentation Vienna, 20 February
More informationDepartment of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, 77. Table of Contents 1
Efficient single photon detection from 500 nm to 5 μm wavelength: Supporting Information F. Marsili 1, F. Bellei 1, F. Najafi 1, A. E. Dane 1, E. A. Dauler 2, R. J. Molnar 2, K. K. Berggren 1* 1 Department
More informationBasic Components of Spectroscopic. Instrumentation
Basic Components of Spectroscopic Ahmad Aqel Ifseisi Assistant Professor of Analytical Chemistry College of Science, Department of Chemistry King Saud University P.O. Box 2455 Riyadh 11451 Saudi Arabia
More informationLecture 21. Wind Lidar (3) Direct Detection Doppler Lidar
Lecture 21. Wind Lidar (3) Direct Detection Doppler Lidar Overview of Direct Detection Doppler Lidar (DDL) Resonance fluorescence DDL Fringe imaging DDL Scanning FPI DDL FPI edge-filter DDL Absorption
More informationLlIGHT REVIEW PART 2 DOWNLOAD, PRINT and submit for 100 points
WRITE ON SCANTRON WITH NUMBER 2 PENCIL DO NOT WRITE ON THIS TEST LlIGHT REVIEW PART 2 DOWNLOAD, PRINT and submit for 100 points Multiple Choice Identify the choice that best completes the statement or
More informationDensity and temperature maxima at specific? and B
Density and temperature maxima at specific? and B Matthew M. Balkey, Earl E. Scime, John L. Kline, Paul Keiter, and Robert Boivin 11/15/2007 1 Slide 1 Abstract We report measurements of electron density
More informationFIBER OPTICS. Prof. R.K. Shevgaonkar. Department of Electrical Engineering. Indian Institute of Technology, Bombay. Lecture: 18.
FIBER OPTICS Prof. R.K. Shevgaonkar Department of Electrical Engineering Indian Institute of Technology, Bombay Lecture: 18 Optical Sources- Introduction to LASER Diodes Fiber Optics, Prof. R.K. Shevgaonkar,
More informationMeasuring optical filters
Measuring optical filters Application Note Author Don Anderson and Michelle Archard Agilent Technologies, Inc. Mulgrave, Victoria 3170, Australia Introduction Bandpass filters are used to isolate a narrow
More informationSolea. Supercontinuum Laser. Applications
Solea Supercontinuum Laser Extended Spectral range: 525 nm - 900 nm (ECO mode), 480 nm - 900 nm (BOOST mode) Extended 2-year worldwide warranty* Supercontinuum output or wavelength selected output through
More informationGuide to SPEX Optical Spectrometer
Guide to SPEX Optical Spectrometer GENERAL DESCRIPTION A spectrometer is a device for analyzing an input light beam into its constituent wavelengths. The SPEX model 1704 spectrometer covers a range from
More informationFluorescence Lifetime Measurements of BODIPY and Alexa Dyes on ChronosFD and K2
Fluorescence Lifetime Measurements of BODIPY and Alexa Dyes on ChronosFD and K2 ISS, Inc. Introduction ChronosFD is the first frequency-domain fluorometer that enables measurement of time-resolved data
More information5. Scintillation counters
5. Scintillation counters to detect radiation by means of scintillation is among oldest methods of particle detection particle impinging on ZnS screen -> emission of light flash principle of scintillation
More informationSPECTRAL IRRADIANCE DATA
The radiometric data on the following pages was measured in our Standards Laboratory. The wavelength calibrations are based on our spectral calibration lamps. Irradiance data from 250 to 2500 nm is based
More informationTunable KiloArc. Tunable Broadband Light Source.
Optical Building Blocks Corporation Tunable KiloArc Tunable Broadband Light Source www.obb1.com Tunable KiloArc Need a CW laser that is tunable from 250 to 1,100 nm? yes Need it to deliver Hundreds of
More informationImproving the Collection Efficiency of Raman Scattering
PERFORMANCE Unparalleled signal-to-noise ratio with diffraction-limited spectral and imaging resolution Deep-cooled CCD with excelon sensor technology Aberration-free optical design for uniform high resolution
More informationSilicon Photomultiplier
Silicon Photomultiplier Operation, Performance & Possible Applications Slawomir Piatek Technical Consultant, Hamamatsu Corp. Introduction Very high intrinsic gain together with minimal excess noise make
More informationTIME-PRESERVING MONOCHROMATORS FOR ULTRASHORT EXTREME-ULTRAVIOLET PULSES
TIME-PRESERVING MONOCHROMATORS FOR ULTRASHORT EXTREME-ULTRAVIOLET PULSES Luca Poletto CNR - Institute of Photonics and Nanotechnologies Laboratory for UV and X-Ray Optical Research Padova, Italy e-mail:
More informationLecture 6 Fiber Optical Communication Lecture 6, Slide 1
Lecture 6 Optical transmitters Photon processes in light matter interaction Lasers Lasing conditions The rate equations CW operation Modulation response Noise Light emitting diodes (LED) Power Modulation
More informationECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the
ECEN 4606 Lab 8 Spectroscopy SUMMARY: ROBLEM 1: Pedrotti 3 12-10. In this lab, you will design, build and test an optical spectrum analyzer and use it for both absorption and emission spectroscopy. The
More informationFunctional Materials. Optoelectronic devices
Functional Materials Lecture 2: Optoelectronic materials and devices (inorganic). Photonic materials Optoelectronic devices Light-emitting diode (LED) displays Photodiode and Solar cell Photoconductive
More informationExperimental Physics. Experiment C & D: Pulsed Laser & Dye Laser. Course: FY12. Project: The Pulsed Laser. Done by: Wael Al-Assadi & Irvin Mangwiza
Experiment C & D: Course: FY1 The Pulsed Laser Done by: Wael Al-Assadi Mangwiza 8/1/ Wael Al Assadi Mangwiza Experiment C & D : Introduction: Course: FY1 Rev. 35. Page: of 16 1// In this experiment we
More informationSECOND HARMONIC GENERATION AND Q-SWITCHING
SECOND HARMONIC GENERATION AND Q-SWITCHING INTRODUCTION In this experiment, the following learning subjects will be worked out: 1) Characteristics of a semiconductor diode laser. 2) Optical pumping on
More informationSimple setup for nano-second time-resolved spectroscopic measurements by a digital storage oscilloscope
NOTE Simple setup for nano-second time-resolved spectroscopic measurements by a digital storage oscilloscope Goro Nishimura and Mamoru Tamura Biophysics, Research Institute for Electronic Science, Hokkaido