Analaysis of Position Accuracy Using Laser Interferometer in Vertical Milling Machine

Size: px
Start display at page:

Download "Analaysis of Position Accuracy Using Laser Interferometer in Vertical Milling Machine"

Transcription

1 Analaysis of Position Accuracy Using Laser Interferometer in Vertical Milling Machine 1* Mr. P. Lingeswaran 2* Pradeep. D, 3* Praveenkumar. B 1* Assistant Professor, 2&3* Student Department of Mechanical Engineering, Shree Venkateshwara Hi-Tech Engineering College, Gobi. Abstract - This paper presents the results of accuracy characterization of a Vertical Machining Center (VMC) in the form of linear errors and temperature variation using a low powered He Ne laser (Renishaw) calibration system along with environmental controller unit. Temperature distribution of the machine was measured using temperature sensors strategically attached to predetermined locations on each axis guides. The accuracy of the VMC is characterized in the form of geometric and thermal errors as a function of machine tool nominal axis position, temperature distribution (air temperature, air pressure). Results show that axis drive motors are the major heat sources. Linear positional accuracy is best when the machine is in cold condition and deteriorates with increasing machine operation time for all three axes. X- axis had worst linear displacement accuracy and maximum reversal errors among the three axes being tested. One of the major errors in machine tools namely geometric error was discussed at length and surface. Continuous usage of a machine tool causes heat generation at the moving elements and this heat causes expansion of the various structural elements of the machine tool. It is this expansion of the structural linkages of the machine that leads to inaccuracy in the positioning of the tool. Thus the overall volumetric error of a machine tool is not only dependent on errors due to the assembly and the specific kinematic structure of the machine but also on the thermal errors., an attempt is made to review the work carried out over the last decade in the estimation and compensation of temperature dependent errors. I. INTRODUCTION One of the most important activities related to the maintenance of the machine tool is periodically checking the geometric and kinematics accuracy of machine tools. Static and dynamic stiffness of machine tools is one of the basic prerequisites for the proper operation of the machine tools. Measurements of certain parameter accuracy of machine tools in the appropriate time of period provide the information needed to define the static and dynamic stiffness of machine tools. On the other hand, the measurement of geometric deviations such as straightness, parallelism, flatness and so on, giving the ability to assess the level of accuracy that is specific machine tools can be used. The light source is split at the surface of the half silvered mirror, half the light being reflected through 90 towards a fixed distance mirror, the remaining half being allowed to pass through to a moveable mirror. The mirrors are aligned so that the recombined beams reflected from the mirrors are parallel and are reflected back towards an observer. If the moveable mirror is positioned further away so that its position is shifted by one quarter wavelength, then the beam will return to the observer 180 out of phase and destructive interference will occur, resulting in darkness. The result is known as destructive interference. In destructive interference the two input waves cancel one another resulting in darkness. One retro-reflector is rigidly attached to a beam-splitter, to form a fixed length reference arm. The other retro- reflector moves relatively to the beam splitter and forms the variable length measurement arm. The laser beam 1 emerging from the ML10 has a single frequency with a nominal wavelength of μm and long-term wave-length stability (in vacuum) better than 0.1 ppm, (all relevant). If the difference in path length does change, the detector sees a signal varying between the extremes of constructive and destructive interference each time the path changes. In practice, for the measurement accuracies, such compensation is only required for linear displacement (positional accuracy) measurement where the change in the difference between the path lengths of the two beams is significant. The Reni Shaw ML10 system is a modular system, capable of measuring, displacement, velocity, angular (pitch and yaw) displacement, flatness, straightness, parallelism and squareness, depending on the measurement kits supplied. 1.1 Positioning Accuracy of Machine Tools Machine tool positioning accuracy is a core descriptor of a machine and indicates its expected level of performance. The accuracy of the components machined is primarily affected by the positioning errors of the machine tools. There are a number of standards and guidelines outlining how to evaluate machine tool positioning accuracy. Therefore a total of 21 errors are present in a three axes machine tool. To achieve higher positioning accuracy, the angular, straightness, and squareness errors must be measured and compensated. The above errors are related to the built-up quality of the machine and to be controlled during manufacture of the machine or improved by mechanical maintenance of machine during periodic calibration. 1.2 Method of Positioning Error Measurement Positioning error results in a relative error between the cutting tool and work-piece which produces inaccuracy on the components. Identification and compensation of these errors are necessary to improve the machine tool accuracy. Various methods of checking the positioning errors of a multi-axes machine are (i) Using slip gauges, step gauges or length bars, (ii) By measuring a part machined by it on a precision Coordinate Measuring Machine (CMM), (iii) Using Laser Interferometer System or (iv) Using Ball Bar System etc. The laser interferometers are commonly used to make extremely accurate measurements of linear displacement and thereafter giving compensation to the machine controller, as the compensation data for positioning and backlash errors are readily available in the system. The basic theory for laser interferometers

2 dates back to the early 1900s with the Michelson Interferometer being one of the earliest devices to demonstrate interferometric measurements of length. A laser interferometer uses a laser source that emits a focused monochromatic light beam. The normal set-up for a laser interferometer uses a stationary laser source, a beam splitter, a stationary reference reflective target, and a mobile reflective target. The emitted beam is projected through the beam splitter which results in two separate beams of light. These beams are then projected onto the two targets (one stationary and the other movable) and reflected back to the beam splitter which combines them into a single beam again. II. LITERATURE REVIEW 1. Location Dependency of Positioning Error in a 3-Axes Cnc Milling Machine R.K. Gupta, S.P. Srivastava, S.K.Yadav, V. Prasad, S.B. Jawale,December 12th 14th, 2014 To produce complex components within a close tolerance value, the machine tools are required to be more accurate than the specified accuracy of the components. Generally to achieve better accuracy of machine tools, laser interferometer systems are used to measure the positioning error and thereafter error compensation is done to improve the accuracy. In case of big size milling machines, it is observed that the accuracy of the machine is not always uniform throughout its work table area. This paper presents a study of error distribution across the work table surface that enables to identify the best location for machining close tolerance components. It also indicates the error involved in the machining, corresponding to the various locations of the machine work table. Keywords: Tolerance, Positioning error, Milling machine. 2. Improvement of Positional Accuracy of Precision Micro Milling Centre Using Pitch Error Compensation And Interferometer, Goran Mijuskovic, Peter Krajnik, JanezKopac, ISSN , Tehnickivjesnik 20, 4(2013), An experimental procedure was performed on precision micro milling center to improve positional accuracy and keep tolerances within the required range for precision manufacturing in tool and die industry. The micro milling processes play an important role in tool and die industry which is facing increasing demands on global market, namely demands related to positional accuracy and repeatability. Laser interferometer was used for measurements of 3-axis machining Centre, where the values for positional accuracy and repeatability were calculated according to ISO standard for all three axes. Values of positional accuracy for X- and Y-axes were out of manufacturer s tolerance (3 µm), while positional repeatability was satisfactory and below 0.7µm for all axes. Based on determined positional errors, correction of pitch error compensation table was performed. The improvement of positional accuracy was significant, with values around 1 µm and below. Finally, measurement uncertainty for accuracy and repeatability was estimated for all axes according to the same standard. 3. Calibaration of Machine Tools by Using of Laser measurement systems, S. Ekinovic, H. Prcanovic, and E. Begovic, January 2013 The need for very precise measurements has emerged with evolution of automatic and CNC machine tools. Precision and accuracy are amongst main requests on modern machine tools. To define and know this characteristic of machine tools standard measuring procedures have been used for many years. Yet, others more advanced approaches and equipment s, like laser measuring systems, are also available for measuring machine parameters like straightness of movements, repeatability, surfaces flatness, parallelism etc. This paper shows comparison of measuring results and measuring procedure between two different laser measuring systems, Damalini D525 and Renishaw ML10. Measurements are performed on DMU monoblock60, CNC universal milling machine. Same type of measurements, straightness measurement of main shaft movement in Y direction, is performed simultaneously by means of both of the laser systems. Results presented in this paper shows that there are differences in between measuring results as well as in between measuring procedures for selected lasers. Hence, the correct choice of measuring device in that sense can save time and decrease costs of machine maintenance. 4. Linear Positioning Errors of 3-Axis Machine Tool, Jerzy JÓZWIK, Przemysław MAZUREK, Marcin WIECZOREK, Marek CZWARNOWSKI,CASTROA H.F.F., BURDEKINB M, pp , 12,2012 This paper presents results of 3-axis CNC machine tool diagnostics performed with XL-80 laser interferometer and XC- 80 environmental compensation unit, including pressure, humidity and temperature sensors. Furthermore, the paper includes the methodology and results of conducted measurements of linear positioning errors, which supplied data for further analysis. The conclusion section presents important results of conducted experiments. Measurement results were presented in figures, charts and tables. 5. Prediction of Angular Errors on a Vertical CNC Milling Machine R.A. MAHDAVINEJAD, No. M2, pp , September 15, 2011 The accuracy and precision of computer numerical control (CNC) machine tools directly affect the dimensional accuracy of machined parts. Accurate detection of machine tool errors with respect to positioning and orientation is imperative to the accuracy of the manufacturing process and, further, to eliminate errors through error compensation techniques. This paper presents a method to measure and determine angular errors resulting from drive axis out-of-straightness. Measurement of errors in discrete steps has been carried out via laser autocollimator and the method of neural networks (NN) has been employed to predict the amount of errors in the range between the steps. The results from this study can be used as a model for industrial applications to identify errors prior to the programming of the manufacturing process. 6. Laser Interferometry For Precision Engineering Metrology, Baer T., Kowalsk, Baldwin, D. R, Opt., 19, 3173, October 21, 2010 Interferometric techniques for the precision measurement of length have found increasing application since the turn of the century. With the advent of compact laser systems of narrow spectral bandwidth and corresponding high coherence, laser interferometry has developed into a standard technique for the measurement of length, displacement, angle and other related dimensional quantities at the highest precision. A number of manufacturers within the high-technology optical industries provide complete stand-alone or OEM length and displacement measuring systems. Most precision engineering concerns now take advantage of the high resolution and accuracy of these devices, both in the calibration of material standards such as gauge blocks and line standards, but also through on-line incorporation of such devices into computer-controlled lathes and three-axis co-ordinate measurement machines.

3 7. A Basic Michelson Laser Interferometer For The Under Graduate Teaching Laboratory Demonstrating Picometer Sensitivity Kenneth G. Libbrechta and Eric D. Black Caltech, Pasadena, California (Received 3 July 2007; accepted 4 November 2007) We describe a basic Michelson laser interferometer experiment for the undergraduate teaching laboratory that achieves picometer sensitivity in a hands-on, table-top instrument. In addition to providing an introduction to interferometer physics and optical hardware, the experiment also focuses on precision measurement techniques including servo control, signal modulation, phase-sensitive detection, and different types of signal averaging. Students examine these techniques in a series of steps that take them from micron-scale sensitivity using direct fringe counting to picometer sensitivity using a modulated signal and phase-sensitive signal averaging. III. COMPONENTS REQUIRED 3.1 Instrument Set-up The setup of the laser interferometer consists of arranging the stationary components (Laser Head, Beam Splitter, Stationary Reflector and Temperature Sensors) and mobile components (Mobile Reflector) of the system so that the relative motion between these components accurately reflects the motion of the machine under measurement. Mounting of the mobile reflector is normally done with a magnetic base, and it is mounted to mimic the motion of the cutting tool of the machine. The Laser Head is mounted off the machine, on a tripod, to insulate it from vibration of the machine in motion. For linear measurement the components are aligned so that the emitted beam leaves the laser head from the upper aperture and is returned from the mobile reflector to the lower aperture, throughout the entire range of motion to be measured. Such essential periodic laser interferometer calibration confirms the traceability measurement chain to the absolute standard for the metre, as basically depicted. Typically, laser interferometers of the homo, or heterodyne-types, are frequently utilized by manufacturing industry at large, and in calibration laboratories for displacement-measurements in a very wide-range, from just 0.1 nm up to that of 50 m distance. The accurate and traceable operation of a laser interferometer requires calibrations and checks of several specific factors. 3.3 Air pressure sensor Air pressure sensor is a device equipped with a pressure -sensitive element that measures the pressure of a gas or a liquid against a diaphragm made of stainless steel, silicon, etc., and converts the measured value into an electrical signal as an output. Air temperature sensors are compared against calibrated reference Pt100- sensors, inside a climate chamber. Figure 3.2 Air Pressure Sensor 3.4 Metal temperature sensor A metal temperature sensor is a device, typically, a thermocouple or RTD that provides for temperature measurement through an electrical signal. A thermocouple (T/C) is made from two dissimilar metals that generate electrical voltage in direct proportion to changes in temperature. An RTD (Resistance Temperature Detector) is a variable resistor that will change its electrical resistance in direct proportion to changes in temperature in a precise, repeatable and nearly linear manner. Material sensors of the instrument and reference Pt100-sensors are attached to a steel block and inserted inside a climate chamber. Figure 3.1 General Arrangements for Laser Interferometer 3.2Calibration of Laser Interferometers Laser interferometer systems are widely employed in the manufacturing and metrology industries for direct precision measurement of length and displacement, particularly in relation to CNC machine tool and co-ordinate measuring machine (CMM) calibration. Many technologically based countries have their own National Metrology Laboratories see an abridged list of them at rear of this book, that can offer an end user/customer a laser calibration service, such as that provided by The NPL within the UK, or for certain industrial/metrology companies which are suitably accredited to undertake such calibration, or periodic recalibration. Typically within the UK, The NPL offers a routineservice for the verification of interferometer system accuracy, which includes the following: Calibration of a stabilized laser source wavelength. Verification of displacement measurement to30m Calibration of environmental compensation transducer compensated system calibration to 2 parts in 107. UKAS accreditation/iso 9000 compliance. Figure 3.3 Metal Temperature Sensor 3.5 Laser receiver The Spectra Precision DR400 Digit Rod digital rod is a versatile, revolutionary tool that eliminates the need for grade rods when checking grades with a rotating laser. The combination of a laser receiver with digital readout, laser distance meter, and built-in tilt sensor provide the information required to take rodless, accurate grade readings, even at tilt angles up to 30 degrees. Various grade rods can be emulated including direct elevation rods, cut/fill rods and indirect reading rods. Units of measure are selectable with the press of a button in meters, decimal feet or fractional inches.

4 3.9 Split gauge Figure 3.4 Laser Receiver 3.6 Magnetic base A magnetic base is a magnetic based on a magnet that can effectively be turned "on" and "off" at will; they are often used in optics and metalworking, e.g., to hold a dial indicator. The vertical post, side arm (as shown in the image at right) and the dial indicator (not shown) are connected by two swiveling connectors. These connectors allow free movement of the arms so that the indicator can be presented to the work in a suitable orientation. The magnetic base may have a "V" cut into the bottom of the base or the back. This "V" allows the base to be attached to a round bar such as the column of a drill press. Figure 3.5 Magnetic Base 3.7 Dial gauge A dial indicator aims at comparing measurements between two objects in order to check the conformity of one of the objects, the second one being the reference The Dial indicator can be used in Manufacturing processes, to check the flatness of a surface before machining it. In metrology, to check the dimensional conformity of a part. In that case, the dial indicator is combined with a checking fixture, used to position the part. 3.8 Software set up The Renishaw Laser Interferometer system is controlled by software on a standard laptop. Renishaw software package was used to collect information from the laser interferometer system. The software was setup to capture the reading of data from the system with the motion of the machine work table. The motion of the machine table was under automatic control of a part program written for this purpose. Setting up the software for linear motion measurement was done by filling in the entries on the setup screens for the control of the XL-80 laser system. Figure 3.6 Split Gauge To check the accuracy of a carpenter s type level, a perfect horizontal surface is not needed. The level is placed on a flat and roughly level; surface and the reading on the bubble tube is noted. This reading indicates to what extent the surface is parallel to the horizontal plane, according to the level, which at this stage is of unknown accuracy. The spirit level is then rotated through 180 degrees in the horizontal plane, and another reading is noted. If the level is accurate, it will indicate the same orientation with respect to the horizontal plane. A different implies that the level is inaccurate Axis Table The 3-axis CNC machining centers still have place in modern manufacturing. Whether a 3 axis milling machine is the right solution for your business depends on a myriad of factors relation to the size of the production run, work piece properties, accuracy and finish requirements, materials costs, stock holding capabilities, etc.. At Geo Kingsbury, we have the knowledge and expertise to analysis all these variables and determine if 3axis milling is still the most profitable option for you. If so, we can recommend the best machine and provide a turnkey service for installation, setup and programming. All our 3 axis machines are aviable with siemens or heidenhain controls Hand Remote One of the primary benefits of a cnc machine is the hands-off operation. Once you ve programmed the machine to mill part you need, you can sit down, grab a crossword and enjoy your coffee. Well, may be it s not that hands off, but you certainly don t have to control the machine manually through the entire operation. Computer control speeds up production of many simple parts as well as makes machining complex shapes faster and more accurate. The remote control enables basic milling operation on the CNC machine without needing to start up your computer to create or edit a CNC program. Figure 3.7 Hand Remote

5 3.12 Alignment of the Interferometer Before the start of the experiment the interferometer has to be aligned. Though the initial alignment of the interferometer is generally not disturbed from one experiment to the other, periodic fine tuning is essential to ensure that the interferometer is operating at its highest sensitivity. The initial alignment of the interferometer is carried out as per the following steps: 1. The light output of the spatial filter is adjusted so that the diffraction rings, which appear with the expanded beam, vanish. This requires adjustment of the screws on the spatial filter. In most experiments, the diffraction ring formed a complete circle and remained outside the periphery of the expanded beam. 2. The laser power output is measured using a light meter. The laser-power output is generally not a stable quantity and changes with time. This change in power output is generally not a stable quantity and changes with time. This change in power output is not a transient phenomena. Instead, it decreases steadily with the hours of operation. During the present work, the laser output was in the range mw over two years. 3. The convex lens is adjusted from the pinhole of the spatial filter so that the distance of separation is the focal length of the lens. This produces a parallel laser beam needed for the experiments. IV. WORKING PRINCIPLE The working principle of interferometry is discovered in 1880 by Albert Michelson. Michelson's interferometer comprises the source of monochromatic light, semitransparent mirror and Renishaw laser system measures accuracy of straightness and repeatability of machine movement by measuring deviation of target points from reference axis. Using RENISHAW laser 10 system straightness of main shaft movement of CNC mill DM 60 mono BLOCK in direction of Y axis is performed. Measurement is performed on a length of 490 mm from outmost position towards machine bed. According to machine producers specification this deviation should be less then 0.02 mm on 300 mm length. Laser source on this laser system is positioned on a tripod outside of a machine, while interferometer is positioned on a movable part and mirror is positioned on a stationary part of a given machine. Deviation of target points from reference axis, which is positioned between laser source and mirror on a stationary part of a machine, is measured. Figure 4.1 Experimental set-up After optics are positioned and connected with laser management software the main shaft is moved from point to point 8 times on a 490 mm length. This procedure is repeated 3 times. The distance between target points is 70 mm. Measurement results are given. Analysis of measurement results according to German standard VDI Maximum deviation on a given length is Umax= which is considerably less from allowable 0.02mm. This machine is calibrated upon its installation using dial gauge and length gauge. Length gauge is of 300 mm and overall deviation is mm, what is in accordance to allowable deviation of 0.02 mm on a 300 mm length. On a semitransparent mirror light beam is split in two parts. One part goes towards movable mirror and the second part is reflected under 90 angle towards fixed mirror. Mirrors are placed in such a way so that recombined light beam goes towards observer. If both mirrors are on the same distance from semitransparent mirror then both beams reflected towards observer will be in phase which will result in amplification of the light intensity. If the movable mirror is placed ¼ wavelengths away from fixed mirror, then the return beam is 180 out from the phase of base light beam and that results in so called "destructive interferometer" which produces dark on a screen. PDS detector is a silicon film sensitive to light.

6 In comparison to digital camera in which the resolution is defined with the camera design these detectors are analog and can have almost unlimited resolution. When laser beam hits silicon film electrical current begin to flow from point of impact towards electrode. The intensity of current is proportional to distances of an impact point from each electrode. Based on intensity of current exact location of laser beam is calculated. 4.1 Uses of Laser Interferometer The uses of a laser interferometer are as given below. (a) Since laser interferometer produce very thin, straight beam, they are used for measurements and alignment in the production of large machines. (b) They are also used to calibrate precision machine and measuring devices. (c) They can also be used to check machine set ups. A laser beam is projected against the work and measurements are made by the beam and displayed on a digital readout panel. (d) Laser interferometers can also be used in glass feature measurements. REFERENCES [1] Choi, J. P., Minb, B.K., Lee, S. J.: Reduction of machining errors of a three-axis machine tools by on-machine measurement and error compensation system, Journal of Materials Processing Technology, vol , pp , Iwasawa, K., Iwamaa, A., Mitsui, K.: Development of a measuring method for several types of programmed tool paths for NC machine tools using a laser displacement interferometer and rotary encoder, Precision Engineering, vol.28, pp , [2] RAINSHAW Laser System Manual, Renishaw plc, Version 7.3. [3] [4] APPENDIX V. ADVANTAGES AND APPLICATIONS 5.1 Advantages Highly durable optics Improved dynamic response Quick thermal acclimatization Easier long-range alignment. It facilitates to maintain long range optical path (60 m). Laser interferometers are easy to install. There is no chance deterioration in performance due to ageing or wear and tear. 5.2 APPLICATIONS It is used to improve the component surface finish. It is used to analysis the 3-axis of the table. It improves the tool life. It increase the position accuracy of axis the machine performance is improved. Measure angles, flatness, straightness, velocity and vibrations, etc. VI. CONCLUSION The need for very precise measurements has emerged with evolution of automatic and CNC machine tools. Precision and accuracy are amongst main requests on modern machine tools. To define and know this characteristic of machine tools standard measuring procedures have been used for many years. Yet, others more advanced approaches and equipments, like laser measuring systems, are also available for measuring machine parameters like straightness of movements, repeatability, surfaces flatness, parallelism etc. This paper presents some examples of measurements of different deviations for different machine tools. These are measurement results of CNC lathe (deviation from linear motion), CNC milling machine (dynamic behaviour), deep drilling machine (straightness), CNC milling machine (comparative measurement straightness according to two different methods of measurement: interferometry and CCD method). Presented results can gave significant help in regular machine shop maintenance activities. Hence, the correct choice of measuring device and method in that sense can save time and decrease costs of machine maintenance.

7. Michelson Interferometer

7. Michelson Interferometer 7. Michelson Interferometer In this lab we are going to observe the interference patterns produced by two spherical waves as well as by two plane waves. We will study the operation of a Michelson interferometer,

More information

PHYS 3153 Methods of Experimental Physics II O2. Applications of Interferometry

PHYS 3153 Methods of Experimental Physics II O2. Applications of Interferometry Purpose PHYS 3153 Methods of Experimental Physics II O2. Applications of Interferometry In this experiment, you will study the principles and applications of interferometry. Equipment and components PASCO

More information

Chapter 7. Optical Measurement and Interferometry

Chapter 7. Optical Measurement and Interferometry Chapter 7 Optical Measurement and Interferometry 1 Introduction Optical measurement provides a simple, easy, accurate and reliable means for carrying out inspection and measurements in the industry the

More information

Difrotec Product & Services. Ultra high accuracy interferometry & custom optical solutions

Difrotec Product & Services. Ultra high accuracy interferometry & custom optical solutions Difrotec Product & Services Ultra high accuracy interferometry & custom optical solutions Content 1. Overview 2. Interferometer D7 3. Benefits 4. Measurements 5. Specifications 6. Applications 7. Cases

More information

Probably the fastest and most precise interferometer currently available

Probably the fastest and most precise interferometer currently available Probably the fastest and most precise interferometer currently available - with Compensation unit - this is all there is - no additional boxes - wireless sensors - 3D and really fast - remarkable! BR 1016

More information

Agilent 10774A Short Range Straightness Optics and Agilent 10775A Long Range Straightness Optics

Agilent 10774A Short Range Straightness Optics and Agilent 10775A Long Range Straightness Optics 7Y Agilent 10774A Short Range Straightness Optics and Agilent 10775A Long Range Straightness Optics Introduction Introduction Straightness measures displacement perpendicular to the axis of intended motion

More information

MEASURING MACHINES. Pratt & Whitney METROLOGY LABORATORY. Measurement Systems, Inc.

MEASURING MACHINES. Pratt & Whitney METROLOGY LABORATORY. Measurement Systems, Inc. METROLOGY LABORATORY Pratt & Whitney Measurement s, Inc. METROLOGY LABORATORY The Standard of Accuracy Pratt & Whitney Metrology Laboratory Machines are the standard to which all other gages are held subordinate.

More information

QUALITY OF CNC MACHINE TOOLS AND MONITORING OF THEIR ACCURACY

QUALITY OF CNC MACHINE TOOLS AND MONITORING OF THEIR ACCURACY 8 th Research/Expert Conference with International Participations QUALITY 2013, Neum, B&H, June 06 08, 2013 QUALITY OF CNC MACHINE TOOLS AND MONITORING OF THEIR ACCURACY Prof. Dr. Ing. Ivan Kuric University

More information

Study of Vee Plate Manufacturing Method for Indexing Table

Study of Vee Plate Manufacturing Method for Indexing Table Study of Vee Plate Manufacturing Method for Indexing Table Yeon Taek OH Department of Robot System Engineering, Tongmyong University 428 Sinseon-ro, Nam-gu, Busan, Korea yeonoh@tu.ac.kr Abstract The indexing

More information

Coherent Laser Measurement and Control Beam Diagnostics

Coherent Laser Measurement and Control Beam Diagnostics Coherent Laser Measurement and Control M 2 Propagation Analyzer Measurement and display of CW laser divergence, M 2 (or k) and astigmatism sizes 0.2 mm to 25 mm Wavelengths from 220 nm to 15 µm Determination

More information

5 m-measurement system for traceable measurements of tapes and rules

5 m-measurement system for traceable measurements of tapes and rules 5 m-measurement system for traceable measurements of tapes and rules Tanfer Yandayan*, Bulent Ozgur Tubitak Ulusal Metroloji Enstitusu (UME) PK54, 4147 Gebze-KOCAELI / TURKEY ABSTRACT Line standards such

More information

MEASURING MACHINE TOOLS WITH BALL BARS

MEASURING MACHINE TOOLS WITH BALL BARS MEASURING MACHINE TOOLS WITH BALL BARS Every time we detect a part that is out of tolerance, the implication is that something went wrong in the machining process: either the operator made a mistake, or

More information

Fast Optical Form Measurements of Rough Cylindrical and Conical Surfaces in Diesel Fuel Injection Components

Fast Optical Form Measurements of Rough Cylindrical and Conical Surfaces in Diesel Fuel Injection Components Fast Optical Form Measurements of Rough Cylindrical and Conical Surfaces in Diesel Fuel Injection Components Thomas J. Dunn, Robert Michaels, Simon Lee, Mark Tronolone, and Andrew Kulawiec; Corning Tropel

More information

Investigation of an optical sensor for small angle detection

Investigation of an optical sensor for small angle detection Investigation of an optical sensor for small angle detection usuke Saito, oshikazu rai and Wei Gao Nano-Metrology and Control Lab epartment of Nanomechanics Graduate School of Engineering, Tohoku University

More information

Stability of a Fiber-Fed Heterodyne Interferometer

Stability of a Fiber-Fed Heterodyne Interferometer Stability of a Fiber-Fed Heterodyne Interferometer Christoph Weichert, Jens Flügge, Paul Köchert, Rainer Köning, Physikalisch Technische Bundesanstalt, Braunschweig, Germany; Rainer Tutsch, Technische

More information

Supplementary Materials

Supplementary Materials Supplementary Materials In the supplementary materials of this paper we discuss some practical consideration for alignment of optical components to help unexperienced users to achieve a high performance

More information

Measurement and compensation of displacement errors by non-stop synchronized data collection

Measurement and compensation of displacement errors by non-stop synchronized data collection Measurement and compensation of displacement errors by non-stop synchronized data collection Charles Wang and Gianmarco Liotto Optodyne, Inc., Compton, California, USA Email: optodyne@aol.com Abstract

More information

Computer Numeric Control

Computer Numeric Control Computer Numeric Control TA202A 2017-18(2 nd ) Semester Prof. J. Ramkumar Department of Mechanical Engineering IIT Kanpur Computer Numeric Control A system in which actions are controlled by the direct

More information

Laser Telemetric System (Metrology)

Laser Telemetric System (Metrology) Laser Telemetric System (Metrology) Laser telemetric system is a non-contact gauge that measures with a collimated laser beam (Refer Fig. 10.26). It measure at the rate of 150 scans per second. It basically

More information

Diagnosis and compensation of motion errors in NC machine tools by arbitrary shape contouring error measurement

Diagnosis and compensation of motion errors in NC machine tools by arbitrary shape contouring error measurement Diagnosis and compensation of motion errors in NC machine tools by arbitrary shape contouring error measurement S. Ibaraki 1, Y. Kakino 1, K. Lee 1, Y. Ihara 2, J. Braasch 3 &A. Eberherr 3 1 Department

More information

SpectroMaster. High Precision Automatic Spectrometer-Goniometer

SpectroMaster. High Precision Automatic Spectrometer-Goniometer SpectroMaster High Precision Automatic Spectrometer-Goniometer CONTENTS Overview 3 Measurement Principle 3 Error A naly sis and System Requirements 4 Goniometer Error...4 Ambient Conditions...6 Sample

More information

Laser scale axis referencing with controllers with low bandwidth sine and cosine inputs

Laser scale axis referencing with controllers with low bandwidth sine and cosine inputs Laser scale axis referencing with controllers with low bandwidth sine and cosine inputs Introduction This document describes the technique used to interface an HS20 laser scale axis to a controller with

More information

CONTRIBUTIONS ABOUT GANTRY MACHINE TOOL GEOMETRIC ACCURACY IMPROVEMENT BY LASER ALIGNMENT

CONTRIBUTIONS ABOUT GANTRY MACHINE TOOL GEOMETRIC ACCURACY IMPROVEMENT BY LASER ALIGNMENT THE INTERNATIONAL CONFERENCE OF THE CARPATHIAN EURO-REGION SPECIALISTS IN INDUSTRIAL SYSTEMS 6 th edition CONTRIBUTIONS ABOUT GANTRY MACHINE TOOL GEOMETRIC ACCURACY IMPROVEMENT BY LASER ALIGNMENT Constantin

More information

OPTICS IN MOTION. Introduction: Competing Technologies: 1 of 6 3/18/2012 6:27 PM.

OPTICS IN MOTION. Introduction: Competing Technologies:  1 of 6 3/18/2012 6:27 PM. 1 of 6 3/18/2012 6:27 PM OPTICS IN MOTION STANDARD AND CUSTOM FAST STEERING MIRRORS Home Products Contact Tutorial Navigate Our Site 1) Laser Beam Stabilization to design and build a custom 3.5 x 5 inch,

More information

General Physics Laboratory Experiment Report 2nd Semester, Year 2018

General Physics Laboratory Experiment Report 2nd Semester, Year 2018 PAGE 1/13 Exp. #2-7 : Measurement of the Characteristics of the Light Interference by Using Double Slits and a Computer Interface Measurement of the Light Wavelength and the Index of Refraction of the

More information

7 WAVEMETER PROJECT #6 MODEL OEK-100. Measure the Wavelength of An Unknown laser Using 633nm and 543 nm HeNe lasers

7 WAVEMETER PROJECT #6 MODEL OEK-100. Measure the Wavelength of An Unknown laser Using 633nm and 543 nm HeNe lasers 7 WAVEMETER Measure the Wavelength of An Unknown laser Using 633nm and 543 nm HeNe lasers MODEL OEK-100 PROJECT #6 72 7.1 Introduction A wavemeter can be constructed with a Twyman-Green interferometer.

More information

Surface Finish Measurement Methods and Instrumentation

Surface Finish Measurement Methods and Instrumentation 125 years of innovation Surface Finish Measurement Methods and Instrumentation Contents Visual Inspection Surface Finish Comparison Plates Contact Gauges Inductive / Variable Reluctance (INTRA) Piezo Electric

More information

This is how PI Does Measuring - Part I

This is how PI Does Measuring - Part I WHITEPAPER This is how PI Does Measuring - Part I This is how PI Does Measuring - Part I Measuring Environment / Measuring Equipment Portfolio / Data Evaluation Physik Instrumente (PI) GmbH & Co. KG, Auf

More information

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad Name Code INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad -500 043 MECHANICAL ENGINEERING TUTORIAL QUESTION BANK : ENGINEERING METROLOGY : A50318 Class : III B.Tech I Semester Branch

More information

FRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION

FRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION FRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION Revised November 15, 2017 INTRODUCTION The simplest and most commonly described examples of diffraction and interference from two-dimensional apertures

More information

Agilent 10705A Single Beam Interferometer and Agilent 10704A Retroreflector

Agilent 10705A Single Beam Interferometer and Agilent 10704A Retroreflector 7B Agilent 10705A Single Beam Interferometer and Agilent 10704A Retroreflector Description Description The Agilent 10705A Single Beam Interferometer (shown in Figure 7B-1) is intended for use in low-mass

More information

SpectroMaster. High Precision Automatic Spectrometer-Goniometer

SpectroMaster. High Precision Automatic Spectrometer-Goniometer SpectroMaster High Precision Automatic Spectrometer-Goniometer CONTENTS Overview 3 Measurement Principle 3 Error Analysis and System Requirements 4 Goniometer Error...4 Ambient Conditions...6 Sample Quality...6

More information

Be aware that there is no universal notation for the various quantities.

Be aware that there is no universal notation for the various quantities. Fourier Optics v2.4 Ray tracing is limited in its ability to describe optics because it ignores the wave properties of light. Diffraction is needed to explain image spatial resolution and contrast and

More information

Understanding Optical Specifications

Understanding Optical Specifications Understanding Optical Specifications Optics can be found virtually everywhere, from fiber optic couplings to machine vision imaging devices to cutting-edge biometric iris identification systems. Despite

More information

SPRAY DROPLET SIZE MEASUREMENT

SPRAY DROPLET SIZE MEASUREMENT SPRAY DROPLET SIZE MEASUREMENT In this study, the PDA was used to characterize diesel and different blends of palm biofuel spray. The PDA is state of the art apparatus that needs no calibration. It is

More information

L-742 Ultra-Precision Roll Alignment System for Printing Presses/Paper Machines

L-742 Ultra-Precision Roll Alignment System for Printing Presses/Paper Machines ujijijijijijijijijijijijijijijijijijijijijijijijijijijijijijijijijijijijijijijijijijijijijijijijijijijijijijijijijijijijiji Application Notes Roll Alignment System Recommendations Printing Presses/Paper

More information

3.0 Alignment Equipment and Diagnostic Tools:

3.0 Alignment Equipment and Diagnostic Tools: 3.0 Alignment Equipment and Diagnostic Tools: Alignment equipment The alignment telescope and its use The laser autostigmatic cube (LACI) interferometer A pin -- and how to find the center of curvature

More information

Laser Speckle Reducer LSR-3000 Series

Laser Speckle Reducer LSR-3000 Series Datasheet: LSR-3000 Series Update: 06.08.2012 Copyright 2012 Optotune Laser Speckle Reducer LSR-3000 Series Speckle noise from a laser-based system is reduced by dynamically diffusing the laser beam. A

More information

NCSL International 2995 Wilderness Place, Suite 107 Boulder, Colorado Office: (303) Fax: (303)

NCSL International 2995 Wilderness Place, Suite 107 Boulder, Colorado Office: (303) Fax: (303) www.metrologycareers.com 1 Instructions for the NCSLI laser pointer interferometer Warnings and cautions The laser pointer is a class 3 laser. A person could be injured if the laser beam is pointed into

More information

Week IX: INTERFEROMETER EXPERIMENTS

Week IX: INTERFEROMETER EXPERIMENTS Week IX: INTERFEROMETER EXPERIMENTS Notes on Adjusting the Michelson Interference Caution: Do not touch the mirrors or beam splitters they are front surface and difficult to clean without damaging them.

More information

PROCEEDINGS OF SPIE. Automated asphere centration testing with AspheroCheck UP

PROCEEDINGS OF SPIE. Automated asphere centration testing with AspheroCheck UP PROCEEDINGS OF SPIE SPIEDigitalLibrary.org/conference-proceedings-of-spie Automated asphere centration testing with AspheroCheck UP F. Hahne, P. Langehanenberg F. Hahne, P. Langehanenberg, "Automated asphere

More information

Instructions for the Experiment

Instructions for the Experiment Instructions for the Experiment Excitonic States in Atomically Thin Semiconductors 1. Introduction Alongside with electrical measurements, optical measurements are an indispensable tool for the study of

More information

The LaserTRACER. Calibration and Testing with Sub-Micron accuracy. Accuracy for measuring machines and machine tools an.

The LaserTRACER. Calibration and Testing with Sub-Micron accuracy. Accuracy for measuring machines and machine tools an. The LaserTRACER Calibration and Testing with Sub-Micron accuracy Accuracy for measuring machines and machine tools an The LaserTRACER The Etalon solution TRAC-CAL for Error Mapping and Compensation TRAC-CHECK

More information

Module 5: Experimental Modal Analysis for SHM Lecture 36: Laser doppler vibrometry. The Lecture Contains: Laser Doppler Vibrometry

Module 5: Experimental Modal Analysis for SHM Lecture 36: Laser doppler vibrometry. The Lecture Contains: Laser Doppler Vibrometry The Lecture Contains: Laser Doppler Vibrometry Basics of Laser Doppler Vibrometry Components of the LDV system Working with the LDV system file:///d /neha%20backup%20courses%2019-09-2011/structural_health/lecture36/36_1.html

More information

Keysight Technologies Optics and Laser Heads for Laser-Interferometer Positioning Systems

Keysight Technologies Optics and Laser Heads for Laser-Interferometer Positioning Systems Keysight Technologies Optics and Laser Heads for Laser-Interferometer Positioning Systems Technical Overview Choose from a large selection of optical components for system design flexibility Table of Contents

More information

The Henryk Niewodniczański INSTITUTE OF NUCLEAR PHYSICS Polish Academy of Sciences ul. Radzikowskiego 152, Kraków, Poland.

The Henryk Niewodniczański INSTITUTE OF NUCLEAR PHYSICS Polish Academy of Sciences ul. Radzikowskiego 152, Kraków, Poland. The Henryk Niewodniczański INSTITUTE OF NUCLEAR PHYSICS Polish Academy of Sciences ul. Radzikowskiego 152, 31-342 Kraków, Poland. www.ifj.edu.pl/reports/2003.html Kraków, grudzień 2003 Report No 1931/PH

More information

Measuring the speed of light

Measuring the speed of light 1 Purpose and comments Determine the speed of light by sending a laser beam through various mediums. Unless you want to see like Helen Keller, do not place your eyes in the beam path. Also, Switch the

More information

ADALAM Sensor based adaptive laser micromachining using ultrashort pulse lasers for zero-failure manufacturing D2.2. Ger Folkersma (Demcon)

ADALAM Sensor based adaptive laser micromachining using ultrashort pulse lasers for zero-failure manufacturing D2.2. Ger Folkersma (Demcon) D2.2 Automatic adjustable reference path system Document Coordinator: Contributors: Dissemination: Keywords: Ger Folkersma (Demcon) Ger Folkersma, Kevin Voss, Marvin Klein (Demcon) Public Reference path,

More information

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI Function All are based on Faraday s law of induction: U M = B v d k U M = Measured voltage induced in the medium perpendicular to the magnetic field and the flow direction. The voltage is tapped at two

More information

3B SCIENTIFIC PHYSICS

3B SCIENTIFIC PHYSICS 3B SCIENTIFIC PHYSICS Equipment Set for Wave Optics with Laser 1003053 Instruction sheet 06/18 Alf 1. Safety instructions The laser emits visible radiation at a wavelength of 635 nm with a maximum power

More information

NEW LASER ULTRASONIC INTERFEROMETER FOR INDUSTRIAL APPLICATIONS B.Pouet and S.Breugnot Bossa Nova Technologies; Venice, CA, USA

NEW LASER ULTRASONIC INTERFEROMETER FOR INDUSTRIAL APPLICATIONS B.Pouet and S.Breugnot Bossa Nova Technologies; Venice, CA, USA NEW LASER ULTRASONIC INTERFEROMETER FOR INDUSTRIAL APPLICATIONS B.Pouet and S.Breugnot Bossa Nova Technologies; Venice, CA, USA Abstract: A novel interferometric scheme for detection of ultrasound is presented.

More information

Agilent 10717A Wavelength Tracker

Agilent 10717A Wavelength Tracker 7I Agilent 10717A Wavelength Tracker MADE Description Description The Agilent 10717A Wavelength Tracker (see Figure 7I-1) uses one axis of a laser measurement system to report wavelength-of-light changes,

More information

Real-Time Scanning Goniometric Radiometer for Rapid Characterization of Laser Diodes and VCSELs

Real-Time Scanning Goniometric Radiometer for Rapid Characterization of Laser Diodes and VCSELs Real-Time Scanning Goniometric Radiometer for Rapid Characterization of Laser Diodes and VCSELs Jeffrey L. Guttman, John M. Fleischer, and Allen M. Cary Photon, Inc. 6860 Santa Teresa Blvd., San Jose,

More information

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Electrical Engineering and Computer Science

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Electrical Engineering and Computer Science Student Name Date MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Electrical Engineering and Computer Science 6.161 Modern Optics Project Laboratory Laboratory Exercise No. 6 Fall 2010 Solid-State

More information

Fabrication, Assembly and Testing of a new X-Y Flexure Stage with substantially zero Parasitic Error Motions. Fig.1 Experimental Set-up

Fabrication, Assembly and Testing of a new X-Y Flexure Stage with substantially zero Parasitic Error Motions. Fig.1 Experimental Set-up Fabrication, Assembly and Testing of a new X-Y Flexure Stage with substantially zero Parasitic Error Motions Shorya Awtar Precision Engineering Research Group, MIT Cap-probe Driver Flexure Plate and Metrology

More information

WALLY ROTARY ENCODER. USER MANUAL v. 1.0

WALLY ROTARY ENCODER. USER MANUAL v. 1.0 WALLY ROTARY ENCODER USER MANUAL v. 1.0 1.MEASUREMENTS ANGULAR POSITIONING a. General Description The angular positioning measurements are performed with the use of the Wally rotary encoder. This measurement

More information

3B SCIENTIFIC PHYSICS

3B SCIENTIFIC PHYSICS 3B SCIENTIFIC PHYSICS Equipment Set for Wave Optics with Laser U17303 Instruction sheet 10/08 Alf 1. Safety instructions The laser emits visible radiation at a wavelength of 635 nm with a maximum power

More information

MEASUREMENT OF POSITIONING ACCURACY IN 1 AXIS

MEASUREMENT OF POSITIONING ACCURACY IN 1 AXIS LS 100 MEASUREMENT OF POSITIONING ACCURACY IN 1 AXIS This is the basic configuration. It is designed for positional calibrations of machine tools, coordinate measuring machines, universal length meters

More information

Keysight Technologies Optical Power Meter Head Special Calibrations. Brochure

Keysight Technologies Optical Power Meter Head Special Calibrations. Brochure Keysight Technologies Optical Power Meter Head Special Calibrations Brochure Introduction The test and measurement equipment you select and maintain in your production and qualification setups is one of

More information

Imaging Systems Laboratory II. Laboratory 8: The Michelson Interferometer / Diffraction April 30 & May 02, 2002

Imaging Systems Laboratory II. Laboratory 8: The Michelson Interferometer / Diffraction April 30 & May 02, 2002 1051-232 Imaging Systems Laboratory II Laboratory 8: The Michelson Interferometer / Diffraction April 30 & May 02, 2002 Abstract. In the last lab, you saw that coherent light from two different locations

More information

Plane Mirror Interferometer Configurations. Functional description. Interferometeranordnung Plane Mirror Interferometer

Plane Mirror Interferometer Configurations. Functional description. Interferometeranordnung Plane Mirror Interferometer B Plane Mirror Interferometer Configurations Plane mirror interferometers are the ideal solution for special duty with a resolution of 1.25nm. Those used for distance, speed and acceleration measurement

More information

LEOK-3 Optics Experiment kit

LEOK-3 Optics Experiment kit LEOK-3 Optics Experiment kit Physical optics, geometrical optics and fourier optics Covering 26 experiments Comprehensive documents Include experiment setups, principles and procedures Cost effective solution

More information

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9 Overview MAGFLO family MAGFLO electromagnetic are designed for measuring the flow of electrically conductive mediums. The patented MAGFLO Verificator guarantees accurate measurement and simple verification.

More information

Development of innovative fringe locking strategies for vibration-resistant white light vertical scanning interferometry (VSI)

Development of innovative fringe locking strategies for vibration-resistant white light vertical scanning interferometry (VSI) Development of innovative fringe locking strategies for vibration-resistant white light vertical scanning interferometry (VSI) Liang-Chia Chen 1), Abraham Mario Tapilouw 1), Sheng-Lih Yeh 2), Shih-Tsong

More information

RENOVATION OF CONVENTIONAL LATHE, MILLING AND DRILLING MACHINES BY USING ENCODERS AND NUMERICAL DISPLAYS

RENOVATION OF CONVENTIONAL LATHE, MILLING AND DRILLING MACHINES BY USING ENCODERS AND NUMERICAL DISPLAYS 2 nd International Conference From Scientific Computing to Computational Enguineering 2 nd IC-SCCE Athens, 5-8 July, 2006 IC- SCCE RENOVATION OF CONVENTIONAL LATHE, MILLING AND DRILLING MACHINES BY USING

More information

Optical Coherence: Recreation of the Experiment of Thompson and Wolf

Optical Coherence: Recreation of the Experiment of Thompson and Wolf Optical Coherence: Recreation of the Experiment of Thompson and Wolf David Collins Senior project Department of Physics, California Polytechnic State University San Luis Obispo June 2010 Abstract The purpose

More information

absolute encoders and motors for -80 C

absolute encoders and motors for -80 C absolute encoders and motors for -80 C motors Choosing a drive system for our application. To be taken into account: speed mechanical load characteristics smoothness of motion resolution temperature other

More information

1.6 Beam Wander vs. Image Jitter

1.6 Beam Wander vs. Image Jitter 8 Chapter 1 1.6 Beam Wander vs. Image Jitter It is common at this point to look at beam wander and image jitter and ask what differentiates them. Consider a cooperative optical communication system that

More information

RTLA50 absolute linear encoder scale system for EVOLUTE

RTLA50 absolute linear encoder scale system for EVOLUTE L-917-9628-02-B RTLA0 absolute linear encoder scale system for EVOLUTE The range of RTLA0 absolute linear encoder scales from Renishaw give ±10 µm/m accuracy in the form of a rugged and easy-to-handle

More information

R.B.V.R.R. WOMEN S COLLEGE (AUTONOMOUS) Narayanaguda, Hyderabad.

R.B.V.R.R. WOMEN S COLLEGE (AUTONOMOUS) Narayanaguda, Hyderabad. R.B.V.R.R. WOMEN S COLLEGE (AUTONOMOUS) Narayanaguda, Hyderabad. DEPARTMENT OF PHYSICS QUESTION BANK FOR SEMESTER III PAPER III OPTICS UNIT I: 1. MATRIX METHODS IN PARAXIAL OPTICS 2. ABERATIONS UNIT II

More information

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the ECEN 4606 Lab 8 Spectroscopy SUMMARY: ROBLEM 1: Pedrotti 3 12-10. In this lab, you will design, build and test an optical spectrum analyzer and use it for both absorption and emission spectroscopy. The

More information

Typical Interferometer Setups

Typical Interferometer Setups ZYGO s Guide to Typical Interferometer Setups Surfaces Windows Lens Systems Distribution in the UK & Ireland www.lambdaphoto.co.uk Contents Surface Flatness 1 Plano Transmitted Wavefront 1 Parallelism

More information

Linear, angular and rotary. encoders. Over 30 years of continuous evolution

Linear, angular and rotary. encoders. Over 30 years of continuous evolution Linear, angular and rotary encoders Over 30 years of continuous evolution Fagor Automation has been manufacturing high quality linear and rotary encoders using precision optical technology for more than

More information

CO2 laser heating system for thermal compensation of test masses in high power optical cavities. Submitted by: SHUBHAM KUMAR to Prof.

CO2 laser heating system for thermal compensation of test masses in high power optical cavities. Submitted by: SHUBHAM KUMAR to Prof. CO2 laser heating system for thermal compensation of test masses in high power optical cavities. Submitted by: SHUBHAM KUMAR to Prof. DAVID BLAIR Abstract This report gives a description of the setting

More information

Ramesh H. Aralaguppi 1, T. Subramanian 2

Ramesh H. Aralaguppi 1, T. Subramanian 2 Study of Spindle Rotational Accuracies versus Bore Accuracies on Machined Test Pieces on a CNC Machining Center Ramesh H. Aralaguppi 1, T. Subramanian 2 Abstract Metal Cutting Machine tools are built to

More information

LOS 1 LASER OPTICS SET

LOS 1 LASER OPTICS SET LOS 1 LASER OPTICS SET Contents 1 Introduction 3 2 Light interference 5 2.1 Light interference on a thin glass plate 6 2.2 Michelson s interferometer 7 3 Light diffraction 13 3.1 Light diffraction on a

More information

Chapter Ray and Wave Optics

Chapter Ray and Wave Optics 109 Chapter Ray and Wave Optics 1. An astronomical telescope has a large aperture to [2002] reduce spherical aberration have high resolution increase span of observation have low dispersion. 2. If two

More information

Lab Report 3: Speckle Interferometry LIN PEI-YING, BAIG JOVERIA

Lab Report 3: Speckle Interferometry LIN PEI-YING, BAIG JOVERIA Lab Report 3: Speckle Interferometry LIN PEI-YING, BAIG JOVERIA Abstract: Speckle interferometry (SI) has become a complete technique over the past couple of years and is widely used in many branches of

More information

Length section: New calibration and research services

Length section: New calibration and research services Length section: New calibration and research services O Kruger October 2015 T026 Overview Traditional traceability chart Traceability chart with length R&D projects Overview of Various R&D projects Conclusion

More information

FIXTURLASER NXA Ultimate

FIXTURLASER NXA Ultimate FIXTURLASER NXA Ultimate Welcome to our world. Since the very beginning in 1984, ACOEM AB has helped industries throughout the world to achieve more profitable and sustainable production. We have reached

More information

PAD Correlator Computer

PAD Correlator Computer ALIGNMENT OF CONVENTIONAL ROATING ARM INSTRUMENT GENERAL PRINCIPLES The most important thing in aligning the instrument is ensuring that the beam GOES OVER THE CENTER OF THE TABLE. The particular direction

More information

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy Qiyuan Song (M2) and Aoi Nakamura (B4) Abstracts: We theoretically and experimentally

More information

Technical Explanation for Displacement Sensors and Measurement Sensors

Technical Explanation for Displacement Sensors and Measurement Sensors Technical Explanation for Sensors and Measurement Sensors CSM_e_LineWidth_TG_E_2_1 Introduction What Is a Sensor? A Sensor is a device that measures the distance between the sensor and an object by detecting

More information

Optics and Laser Heads for Laser-Interferometer Positioning Systems Product Overview

Optics and Laser Heads for Laser-Interferometer Positioning Systems Product Overview Optics and Laser Heads for Laser-Interferometer Positioning Systems Product Overview Choose from a large selection of optical components for system design flexibility Table of Contents 3 4 6 8 8 9 10 12

More information

1/8 m GRATING MONOCHROMATOR

1/8 m GRATING MONOCHROMATOR 1/8 m GRATING GRATING OUTPUT PORT INPUT PORT 77250 1/8 m Monochromator with 6025 Hg(Ar) Spectral Calibration Lamp. Low cost, compact size and high performance, ideal for OEM applications Very efficient

More information

LION PRECISION. TechNote LT February, Capacitive Sensor Operation and Optimization

LION PRECISION. TechNote LT February, Capacitive Sensor Operation and Optimization LION PRECISION TechNote LT03-0020 February, 2009 Capacitive Sensor Operation and Optimization Contents Capacitance and Distance 2 Focusing the Electric Field 3 Effects of Target Size 3 Range of Measurement

More information

:... resolution is about 1.4 μm, assumed an excitation wavelength of 633 nm and a numerical aperture of 0.65 at 633 nm.

:... resolution is about 1.4 μm, assumed an excitation wavelength of 633 nm and a numerical aperture of 0.65 at 633 nm. PAGE 30 & 2008 2007 PRODUCT CATALOG Confocal Microscopy - CFM fundamentals :... Over the years, confocal microscopy has become the method of choice for obtaining clear, three-dimensional optical images

More information

5. Transducers Definition and General Concept of Transducer Classification of Transducers

5. Transducers Definition and General Concept of Transducer Classification of Transducers 5.1. Definition and General Concept of Definition The transducer is a device which converts one form of energy into another form. Examples: Mechanical transducer and Electrical transducer Electrical A

More information

M-041 M-044 Tip/Tilt Stage

M-041 M-044 Tip/Tilt Stage M-041 M-044 Tip/Tilt Stage Piezo Drive Option for Nanometer Precision Ordering Information Linear Actuators & Motors M-041.00 Small Tilt Stage, Manual Micrometer Drive M-041.D01 Small Tilt Stage, DC-Motor

More information

9. Microwaves. 9.1 Introduction. Safety consideration

9. Microwaves. 9.1 Introduction. Safety consideration MW 9. Microwaves 9.1 Introduction Electromagnetic waves with wavelengths of the order of 1 mm to 1 m, or equivalently, with frequencies from 0.3 GHz to 0.3 THz, are commonly known as microwaves, sometimes

More information

A DUAL-RECEIVER METHOD FOR SIMULTANEOUS MEASUREMENTS OF RADOME TRANSMISSION EFFICIENCY AND BEAM DEFLECTION

A DUAL-RECEIVER METHOD FOR SIMULTANEOUS MEASUREMENTS OF RADOME TRANSMISSION EFFICIENCY AND BEAM DEFLECTION A DUAL-RECEIVER METHOD FOR SIMULTANEOUS MEASUREMENTS OF RADOME TRANSMISSION EFFICIENCY AND BEAM DEFLECTION Robert Luna MI Technologies, 4500 River Green Parkway, Suite 200 Duluth, GA 30096 rluna@mi-technologies.com

More information

More Info at Open Access Database by S. Dutta and T. Schmidt

More Info at Open Access Database  by S. Dutta and T. Schmidt More Info at Open Access Database www.ndt.net/?id=17657 New concept for higher Robot position accuracy during thermography measurement to be implemented with the existing prototype automated thermography

More information

Fabrication of large grating by monitoring the latent fringe pattern

Fabrication of large grating by monitoring the latent fringe pattern Fabrication of large grating by monitoring the latent fringe pattern Lijiang Zeng a, Lei Shi b, and Lifeng Li c State Key Laboratory of Precision Measurement Technology and Instruments Department of Precision

More information

Chapter 25. Optical Instruments

Chapter 25. Optical Instruments Chapter 25 Optical Instruments Optical Instruments Analysis generally involves the laws of reflection and refraction Analysis uses the procedures of geometric optics To explain certain phenomena, the wave

More information

Kit for building your own THz Time-Domain Spectrometer

Kit for building your own THz Time-Domain Spectrometer Kit for building your own THz Time-Domain Spectrometer 16/06/2016 1 Table of contents 0. Parts for the THz Kit... 3 1. Delay line... 4 2. Pulse generator and lock-in detector... 5 3. THz antennas... 6

More information

Exp No.(8) Fourier optics Optical filtering

Exp No.(8) Fourier optics Optical filtering Exp No.(8) Fourier optics Optical filtering Fig. 1a: Experimental set-up for Fourier optics (4f set-up). Related topics: Fourier transforms, lenses, Fraunhofer diffraction, index of refraction, Huygens

More information

9/28/2010. Chapter , The McGraw-Hill Companies, Inc.

9/28/2010. Chapter , The McGraw-Hill Companies, Inc. Chapter 4 Sensors are are used to detect, and often to measure, the magnitude of something. They basically operate by converting mechanical, magnetic, thermal, optical, and chemical variations into electric

More information

4DAD, a device to align angularly and laterally a high power laser using a conventional sighting telescope as metrology

4DAD, a device to align angularly and laterally a high power laser using a conventional sighting telescope as metrology 4DAD, a device to align angularly and laterally a high power laser using a conventional sighting telescope as metrology Christophe DUPUY, Thomas PFROMMER, Domenico BONACCINI CALIA European Southern Observatory,

More information

Automatic hardness testing devices

Automatic hardness testing devices Automatic hardness testing devices The measure of hardness, applied to rubber and plastic, is a measure of stiffness obtained from an indentation test. An indentor is pressed into the sample under a given

More information

Agilent 5527A/B-2 Achieving Maximum Accuracy and Repeatability

Agilent 5527A/B-2 Achieving Maximum Accuracy and Repeatability Agilent 5527A/B-2 Achieving Maximum Accuracy and Repeatability Product Note With the Agilent 5527A/B Laser Position Transducer System 2 Purpose of this Product Note The ability to model the performance

More information