Fitting Peripheral Prisms for Patients with Hemianopia. The workshop is sponsored by Chadwick Optical, Inc.

Size: px
Start display at page:

Download "Fitting Peripheral Prisms for Patients with Hemianopia. The workshop is sponsored by Chadwick Optical, Inc."

Transcription

1 Fitting Peripheral Prisms for Patients with Hemianopia Eli Peli, MSc, OD, FAAO Professor of Ophthalmology, Harvard Medical School Moakley Scholar in Aging Eye Research Please silence all mobile devices and remove items from chairs so others can sit. Unauthorized recording of this session is prohibited. Disclosure Statement: Patents, Consulting, Funding of Research The workshop is sponsored by Chadwick Optical, Inc. OS Field 2011, Eli Peli, Schepens Eye Research Institute 2011, Eli Peli, Schepens Eye Research Institute OS Fiel d OD Fiel d 2011, Eli Peli, Schepens Eye Research Institute 2011, Eli Peli, Schepens Eye Research Institute 1

2 OU Field OS Fiel d OD Fiel d Optic Chiasm Post Chiasmal Lesion 2011, Eli Peli, Schepens Eye Research Institute OU Field Vision with Hemianopia OS Fiel d OD Fiel d Post Chiasmal Lesions Cortical Lesion 2011, Eli Peli, Schepens Eye Research I tit t RNIB London Typical Static Simulation Visual scene with normal field Visual scene with left HH 2

3 Visual scene with gaze left Visual scene with further left gaze Visual scene with extreme left gaze Visual scene with gaze center Visual scene with gaze right Outline Prior Approaches and their Limitations The Peripheral Prisms and Their Use Clinical Trials Evaluating the Use of P Prisms Fitting the Peripheral Prisms Training Patients in the Use of the Prism Oblique Prisms Fitting Fitting the Prisms - Hands-on Training 3

4 Prior Prism Approaches and their Limitations Binocular Overall Prisms Yoked Prisms Field shift only No field gained Cohen, J.M. & Waiss, B., Visual Field Remediation, Chapter 1, Remediation and Management of Low Vision 1996 Why only 20 Higher power Larger effect Heavy and thick lenses Poor image quality Unacceptable foveally even with ophthalmic prism Worse with Fresnel Bilateral Sector Prisms Right Hemianopia Bilateral Sector Prisms Prism on both lenses prism base to the field loss Prism on half of lenses Most positions of gazeno effect at all Apical Scotoma with Bilateral Sector Prisms Optical Blind Spot- Apical Scotoma On right gaze - only shift image Do not expand the field Right Hemianopia Cohen, J.M. & Waiss, B., Visual Field Remediation, Chapter 1, Remediation and Management of Low Vision

5 Apical Scotoma in Any Prism With Binocular Sector Prism looking straight ahead With Right Hemianopia With Right Hemianopia Without Prism looking to the right With Prism looking to the right Apical Scotoma- Optical Blind Spot With Right Hemianopia With Right Hemianopia 5

6 Unilateral Sector Prisms Using Fresnel Press-on Prisms 3M Prism on one lens only on side of the field loss Most positions of gazeno effect at all Unilateral Sector Prism Right Hemianopia On right gaze -? Right Hemianopia Cohen, J.M. & Waiss, B., Visual Field Remediation, Chapter 1, Remediation and Management of Low Vision, 1996 Just Flipped for Left Hemianopia Unilateral Sector Prism Left Gaze Left Hemianopia Cohen, J.M. & Waiss, B., Visual Field Remediation, Chapter 1, Remediation and Management of Low Vision, 1996 Cohen, J.M. & Waiss, B., Visual Field Remediation, Chapter 1, Remediation and Management of Low Vision 1996 Unilateral Sector Prism Left Gaze OS only Field Expansion Prism Eye PP PP Diplopia Central Disturbing Magnitude of effects Annoying illustrated is incorrect Cohen, J.M. & Waiss, B., Visual Field Remediation, Chapter 1, Remediation and Management of Low Vision 1996 OD only OS view Blocked by Apical Scotoma. Immaterial seen without and with prism Visual Field With Large Gaze Shift Computed With 20 Sector prisms Gaze shifted 20 into the Prism Expanded Field Diplopia 6

7 View with gaze center With unilateral sector prism 20Δ View of scene with gaze right No effect of prism No effect of prism View with gaze center View with 20 gaze left No Prism No effect of prism View with 20 gaze left into prism Diplopia Expansion PP 10 Most Saccades are Less than 15 Magnitude of Gaze Shift PP Gaze Shift Gaze Shift- PP PP Cohen, J.M. & Waiss, B., Visual Field Remediation, Chapter 1, Remediation and Management of Low Vision 1996 What happens if gaze shift is Less than 10? 7

8 Visual Field Unilateral Sector Prism View with gaze center Computed With 20 Sector prisms Expanded Field Central Scotoma Gaze shifted 5 into the Prism No effect of prism View with 11 gaze left No Prism View with 5 gaze left into prism (11 Gaze shift) Where is the Apical Scotoma? Expansion Prism is 2 mm left - 6 left Note apical scotoma Limitations of Prior Approaches Most positions of gaze unaffected by prisms Requires scanning to blind side Diplopia in central vision Annoying and disturbing Apical scotoma in central field Do no harm? Acuity limits prism power centrally Expansion limited to 10 Peripheral Prisms and Their Use 8

9 Hemianopia and no Strabismus Hemianopia with Exotropia Right Hemianopia with Right Exotropia Right Hemianopia Field Expansion Reported in Congenital Hemianopia Panoramic vision Hemianopia and Exotropia About 24 cases of teenagers many with documented ARC reported Surgeons usually do not operate on exotropes with hemianopia Works also with esotropia of the other eye One such teenage case reported I have seen 2 more Right Hemianopia with LEFT Esotropia Field Expansion with Small peripheral loss with Diplopia Except if ARC Hemianopia with Esotropia Turn Hemianopes to Exotropes? No surgery needed We know how to do it with a simple prism Problem - Exotropia causes double vision Adults do not develop ARC Diplopia and Confusion are unacceptable in central vision Field Expansion Solution Make Hemianopes Strabismic Diplopia is a problem Double vision peripherally, easy to adapt Physiological Diplopia 9

10 Horopter Zone of single binocular vision Peripheral Prisms Peripheral Unilateral Prism Left Hemianopia Peripheral Prism Horizontal Design 3M press-on 40 prism segments on upper & lower parts of carrier lens Visual field expansion measured by Goldman perimetry Binocular visual fields - Left hemianopia Users always look through central, prism-free area; No central diplopia Prisms on left lens Base left for left hemianopia Without peripheral prisms With 40 peripheral prisms Properties of Peripheral Prisms High prism power possible in periphery (57 Expand upper and lower fields by up to 30 (even more) Double vision is limited to periphery Maintain single central vision Double vision (confusion) peripherally, easy to adapt Apical scotoma limited to periphery Apical scotoma reduces diplopia All positions of gaze affected by prisms Only with Press-On with inside lens configuration With 57 gets 30º expansion Calculated Measured Apfelbaum, Ross, Bowers, Peli (2013) Considering apical scotomas when prescribing prisms for homonymous hemianopia.translational Vis.Sci. & Technology 10

11 View with Left HH No prism Peripheral prism with gaze center No Diplopia Expansion (confusion) Properties of Peripheral Prisms High prism power possible in periphery (57 Expand upper and lower fields by up to 30 (even more) Double vision is limited to periphery Maintain single central vision Double vision peripherally, easy to adapt Apical scotoma limited to periphery Apical scotoma reduces diplopia All positions of gaze affected by prisms Only with Press-On with inside lens configuration No Escape from the Apical Scotoma Properly designed apical scotoma prevents diplopia in primary gaze 57 30º Properties of Peripheral Prisms High prism power possible in periphery (57 Expand upper and lower fields by up to 30 (even more) Double vision is limited to periphery Maintain single central vision Double vision peripherally, easy to adapt Apical scotoma limited to periphery Apical scotoma reduces diplopia All positions of gaze affected by prisms Not really Only with eyeward prism serration (EPS) configuration Works at Any Position of Gaze Gaze 15 left True only for EPS configuration Gaze 15 right Works but effect is small 11

12 View with gaze center-peripheral prism View with 5 gaze left-peripheral prism Increased field & some distortion Expansion (confusion) Expansion (confusion) Jung JH, Peli E (2014) Impact of high power and angle of incidence on prism corrections for visual field loss, Optical Engineering View with 20 gaze left-peripheral prism Improve Image Quality Safety & Cosmesis Minimal Increased field peripherally. It is limited by TIR Total Internal Reflection Permanent Prism Solid PMMA Fresnel European Permanent Prism in 40Δ or 57Δ Improved Cosmetics and Safety // 12

13 Better cosmetics with sun clip-on Clinical Studies and Clinical Trials Completely invisible // Evaluations of peripheral prisms Long-term benefit in obstacle avoidance for at least 50% of wearers in: Case series report 1 Laboratory extended wear trial 2 Multi-center clinical trial 3 Independent clinical study 4 All with 40Δ prisms 1. Peli E. (2000) Optom Vis Sci. 77: Giorgi RG, Woods RL, Peli E. (2009) Optom Vis Sci. 86: Bowers AR, Keeney K, Peli E (2008) Arch Ophthalmol 126, O'Neill, E. Connell, et al. (2011) Prism therapy and visual rehabilitation in homonymous visual field loss Optometry and Vision Science Community-Based Multi-Center Study Long-term follow up to evaluate: Fitting procedures Patient acceptance Functional utility Preliminary evaluation of permanent prisms Main outcome measures Minimum inter-prism separation Long-term success rate (continue to wear) Helpfulness for obstacle avoidance Community-Based Multi-Center Study 60 patients screened in 18 clinics Complete hemianopia, no neglect 5 excluded, 12 withdrew pre-fitting 43 fitted with prisms Determine minimum inter-prism separation tolerated for walking Tolerated = comfortable single central vision with no change in head posture between without and with prisms Of the 43 that were fitted 32 (74%) continued wear after week 6 follow up 21 (49%) continued long term wear (median 12 months) Success rates varied between clinics More patients higher success rate Section cut out for spot reading X 13

14 Final prism fitting positions Number of patients Interprism separation (mm) An inter-prism separation of 12mm adopted for a simplified fitting protocol Bowers et al. Archives of Ophthalmology, 2008 Fitting the Peripheral Prisms Demonstration Need a Volunteer Basic Fitting Protocol Frame selection and fitting Adjustable nose pads Fitting well and does not slip At least 36mm in the vertical B dimension At least 18mm from pupil center to upper eye wire Upper eye wire at about the level of eyebrow At least 18mm from pupil center to lower eye wire 23mm for bifocals Evaluated in Second Multicenter Clinical Trial Using a cling-on single piece template Template has a fixed inter-prism separation of 12mm Initial Fitting Position Mark pupil center on demo lens Copy the center mark to back of the lens Center the Template on pupil position Laterally and vertically This is the initial fitting position Rub template well in the center to improve optical quality Initial Fitting Position 14

15 Degrees and mm 1 deg is about 0.35 mm on carrier lens 1 mm 3 degrees Initial position of template Prisms are placed 6 mm above and below pupil About 16.5 degrees above and below Adjusted Position Observe head posture while walking-no prism Place an occluder in front of the fellow eye Explain that black patches represent locations of prism segments in the real glasses Can use prism in place of black patch Explain lack of Rx correction in demo lenses Place glasses on patient and take for a walk Changes in head posture observed? Interference of patches noted by patient? Adjust Template position up or down as needed Prisms Position Effect on Head Posture When Walking Tolerated = comfortable single central vision with no change in head posture between without and with prisms Observe head posture when walking without template or prism Initial prisms position is 6mm above and below pupil center Observe head posture when walking with template or prism Do not forget to cover the other eye Lower Template or Prism Position Lower position 2 mm at a time Observe head posture when walking Move down until causes problem Observe head posture when walking with lower prisms position Expected change in head posture? Causing double vision? If using prism instead of template Higher Template or Prism Position Raise position 2 mm at a time Observe head posture when walking Move template up until causes problem Observe head posture when walking with higher prisms position Expected change in head posture? Causing double vision? If using prism instead of template 15

16 Verify sufficient clearance for structural integrity (3mm) Determine final position Clearance should be > 3mm Marked on Template If needed shift template temporally but not more than 3mm When satisfied secure template in position with a tape Can you increase the field expansion by shifting prism temporally towards the field loss?? No! Field expansion is determined by prism power Shifting Prism Temporally is Not Helpful Upper segment shifted temporally mm Temporal prism shift Upper segment shifted temporally 15 5 mm Apex Scotoma Shifted Centrally With 57Δ OPS Shifting Prism Temporally Increases Possibility of Spurious Reflection Shifting Prism Nasally Increases Diplopia Nasal prism shift Upper segment shifted Nasally mm Jung JH, Peli E (2014) Impact of high power and angle of incidence on prism corrections for visual field loss, Optical Engineering Apfelbaum, Ross, Bowers, Peli (2013) Considering apical scotomas when prescribing prisms for homonymous hemianopia. Transl. Vis. Sci. & Technology 16

17 Simulating the Monocular View with High Power Prisms Gaze 10 Left Simulating the Monocular View with Different Configurations Gaze Center OPS 57Δ Outward Prismatic Surface Diplopia Scene field-of-view at primary gaze EPS 57Δ Eyeward Prismatic Surface Jung JH, Peli E (2014) Impact of high power and angle of incidence on prism corrections for visual field loss, Optical Engineering Simulating the Monocular View with Different Configurations OPS 57Δ Gaze 20 Left Gaze 10 Left EPS 57Δ Eyeward Prismatic Surface Template position can be used to fit Temporary Pre Cut Prisms or Permanent Prisms Newer Design Oblique Peripheral Prisms Pre Cuts speed up fitting and may be use without template once experienced Specifically for Driving 17

18 Binocular Perimetry Oblique Prisms Without Prisms Left hemianopia With Prisms Field of view through windshield Peli E. (2008) Peripheral Field Expansion Device. US patent #7,374,284 Oblique peripheral prism glasses Visual field expansion Binocular visual fields - Left hemianopia High Power Oblique Prisms With horizontal prisms Field of view through windshield Field expansion in area relevant to driving With 40 Oblique prisms We now have 57Δ peripheral prisms 40 providing 22º expansion 57 providing 30º expansion 57 Oblique Prisms tilted at 25 Placebo-Controlled, Crossover Trial of Real and Sham Prism Glasses Two treatment groups Real oblique and sham horizontal Real horizontal and sham oblique Order of real/sham counterbalanced Real 57 oblique Sham <5 horizontal 18

19 Main Results 73 Enrolled 61 completed the cross-over 37 (61%) clinical decision to continue wear No difference between oblique and horizontal 25 (41%) still wearing at 6 months Bowers, Keeney, & Peli (2014) Randomized crossover clinical trial of real and sham peripheral prism glasses for hemianopia JAMA Ophth. Comparison questionnaire If you were only allowed to keep one pair of glasses, which would you choose? First pair? Second pair? Neither? Comparison questionnaire Which pair of glasses would you choose? Percent of patients complete crossover p < % chose sham Real Sham Neither Emphasizes the importance of including a control condition Comparison questionnaire Which pair of glasses would you choose? Reasons for choosing real or sham Percent "yes" responses Chose real p = More helpful when walking Chose sham Vision more comfortable On-road driving with prisms study Three routes, each ~ 1 hour Busy streets in Ghent, Belgium Dual-control car Two evaluators: Examiner of the Belgian Road Safety Institute Back seat evaluator On-road driving - Procedures One pre-fitting on-road test without prisms Two post-fitting on-road tests With sham prisms (oblique) With real prisms (oblique) Evaluators masked Bowers, Tant & Peli (2012) A pilot evaluation of on-road detection performance by drivers with hemianopia using oblique peripheral prisms. Stroke Research and Treatment, Article ID

20 Satisfactory responses to unexpected hazards p < No Sham Real Prism Prism Prism Satisfactory = Score of 4 or 5 Error bars = 95% confidence Percent Satisfactory Interventions by driving instructors: brake, gas, steering Number Blind side No Prism Sham Prism Seeing side Real Prism Fewer blind-side interventions with real prisms Fewer is better here Recent driving simulator study Pedestrian on a Collision Course Slow Motion Horizontal field of view 225 Houston et al (2016) A pilot study of perceptual-motor training for peripheral prisms Translational Vis. Science & Technology Pedestrian on a Collision Course Normal Motion Blind side pedestrian detection rates In the driving simulator With prisms (%) Detection rate (%) - With prisms Without prisms (%) Houston et al (2017) Driving with hemianopia VI: peripheral prisms improve blind-side detection in a driving simulator TVST, Submitted 20

21 Blind Side Pedestrian Detection Rate Before Training Detection rate (%) - With prisms With prisms (%) Without prisms (%) Blind Side Pedestrian Detection Rate After Training Detection rate (%) - With prisms With prisms (%) week Detection Without rate (%) prisms - Without (%) prisms Blind Side Pedestrian Detection Rate 3 Months After Training Detection rate (%) - With prisms With prisms (%) week 0 3 months Detection Without rate (%) prisms - Without (%) prisms Training Patients in Use of the Prism In-office training Demonstration of expansion effect Binocular confrontation visual fields Head turning Fixate objects detected via prism image through the clear carrier section Demonstration of undesirable central diplopia Reach-and-touch exercise Familiarization with shifted directions of objects Wear prism glasses as much as possible Except driving and extended reading Home training instructions Wear prism glasses as much as possible Except driving and extended reading Practice use first in familiar environments Gradually expand range & complexity Always have a companion when expanding range first Take other glasses with you in case of need to remove Practice reach and touch exercises Use head movement when not exercising 21

22 New Fitting Designs FitOvers Peripheral Prisms FitOvers over Rx glasses Less expansive; Provides Rx for prism Wearing normal Rx glasses FitOvers over Rx glasses One size may not fit all well; Too low here Provides Correction also through prism Magnetic Clip-On Glasses Magnetic Clip-On Prisms Can be bifocal/pal Rx through prism; Inexpensive to change Rx 22

23 MultiLens, Sweden - Hang On Rx through prism; Inexpensive to change Rx Higher Power Prisms Needed to support detection of other pedestrians in open space environments Maximum risk from such pedestrian is at eccentricity of 45º Current prisms are 30º Peli et al. (2016) The risk of pedestrian collisions with peripheral visual field loss J. of Vision High power without the limitation of the TIR Bi-Part Prism Needed to enable effective scanning to the blind side Peli et al. (2016) High power prismatic devices for oblique peripheral prisms Optometry and Vision Science Bi-part: Higher power With a gap Which is better? 45 prisms monitor 46% of potential collisions Mirror-Based Prism-like device Wide shift, Narrow field Cascade to widen the field 57Δ Lower power No gap 30 prisms monitor 26% of potential collisions Cascade converges rapidly limiting field width Peli E. Peripheral Field Expansion Device. US patent 7,374,

24 The Latest and Greatest! Novel design overcomes the convergence limitation Provides many other advantages Wide field High power High deflection 45º and more Low distortion level Dramatic image quality To be disclosed & demonstrated at workshop Panoramic Street View View with Upper Peripheral Prism 57Δ (30 ) Fresnel Mirror-based (45 ) Pictures of the Novel Peripheral Prisms To be available at the workshop Workshop Equipment & Supplies All provided by Chadwick Optical What is in your personal kits is yours to keep Demo glasses, demo clip-ons, tools etc. are provided for the workshop use only Please, do not take anything that is not in your kit More Information Find it all on our web site Also on Chadwick Optical web site And on MA Medicaid is paying $650-$750 for a pair of these 24

Schedule of Workshop. 3 hours Actually means 3 X 50 Min = 2.5 Hours Finishing at 3:30PM. Fitting Peripheral Prisms for Patients with Hemianopia

Schedule of Workshop. 3 hours Actually means 3 X 50 Min = 2.5 Hours Finishing at 3:30PM. Fitting Peripheral Prisms for Patients with Hemianopia Fitting Peripheral Prisms for Patients with Hemianopia Eli Peli, MSc, OD, FAAO Professor of Ophthalmology, Harvard Medical School Moakley Scholar in Aging Eye Research Please silence all mobile devices

More information

Peripheral Prism Glasses for Hemianopia Giorgi et al. APPENDIX 1

Peripheral Prism Glasses for Hemianopia Giorgi et al. APPENDIX 1 1 Peripheral Prism Glasses for Hemianopia Giorgi et al. APPENDIX 1 Monocular and binocular sector prisms are commonly used for hemianopia.3, 10, 14 The impact of these prisms on the visual field is not

More information

Driving simulators in hemianopia rehabilitation research

Driving simulators in hemianopia rehabilitation research Schepens Eye Research Institute Massachusetts Eye and Ear Harvard Medical School Affiliate Driving simulators in hemianopia rehabilitation research Alex Bowers, PhD No disclosures Hemianopia Loss of half

More information

Heidi Panchaud, Tammy Labreche

Heidi Panchaud, Tammy Labreche Heidi Panchaud, Tammy Labreche Review types of peripheral field loss Review common field enhancement options Training with prisms Care of prisms Training with reverse telescopes Binasal Hemianopia BitemporalHemianopia

More information

Interventions for vision impairments post brain injury: Use of prisms and exercises. Dr Kevin Houston Talia Mouldovan

Interventions for vision impairments post brain injury: Use of prisms and exercises. Dr Kevin Houston Talia Mouldovan Interventions for vision impairments post brain injury: Use of prisms and exercises Dr Kevin Houston Talia Mouldovan Disclosures Dr. Houston: EYEnexo LLC, EyeTurn app Apps discussed are prototypes and

More information

Award Number: W81XWH TITLE: Rehabilitation of Visual and Perceptual Dysfunction after Severe Traumatic Brain Injury

Award Number: W81XWH TITLE: Rehabilitation of Visual and Perceptual Dysfunction after Severe Traumatic Brain Injury AD Award Number: W81XWH-11-2-0082 TITLE: Rehabilitation of Visual and Perceptual Dysfunction after Severe Traumatic Brain Injury PRINCIPAL INVESTIGATOR: Eliezer Peli CONTRACTING ORGANIZATION: Schepens

More information

Important Notes: Construction Details of FX glasses for Left Hemianopes (c) 2006 by The N.I.R.E. Page 1

Important Notes: Construction Details of FX glasses for Left Hemianopes (c) 2006 by The N.I.R.E. Page 1 Construction Details for N.I.R.E. Type-2 Field-Expander Eyeglasses for People with Left *Homonymous* Hemianopsia or Bi-Temporal Hemianopsia... or Hemianopic-Monocular Vision ===========================================================================================

More information

Video Test to Evaluate Detection Performance of Drivers with Hemianopia: Preliminary Results

Video Test to Evaluate Detection Performance of Drivers with Hemianopia: Preliminary Results University of Iowa Iowa Research Online Driving Assessment Conference 2013 Driving Assessment Conference Jun 19th, 12:00 AM Video Test to Evaluate Detection Performance of Drivers with Hemianopia: Preliminary

More information

Suppression in strabismus

Suppression in strabismus British Journal ofophthalmology, 1984, 68, 174-178 Suppression in strabismus an update J. A. PRATT-JOHNSON AND G. TILLSON From the Department of Ophthalmology, University ofbritish Columbia, Vancouver,

More information

Contact Lenses Didn t Work! Now What? Evaluation and Treatment of Aniseikonia

Contact Lenses Didn t Work! Now What? Evaluation and Treatment of Aniseikonia Contact Lenses Didn t Work! Now What? Evaluation and Treatment of Aniseikonia Andrew J Toole, OD, PhD, FAAO The Ohio State University College of Optometry Disclosure Statement: Nothing to disclose Aniseikonia

More information

Chapter 4 Assessment of Study Measures

Chapter 4 Assessment of Study Measures Chapter 4: Assessment of Study Measures...2 4.1 Overview...2 4.1.1 Overview of Eligibility and Masked Examination Procedures...2 4.1.2 Equipment Needed for Masked Examination Procedures...3 4.2 Primary

More information

UNITY VIA PROGRESSIVE LENSES TECHNICAL WHITE PAPER

UNITY VIA PROGRESSIVE LENSES TECHNICAL WHITE PAPER UNITY VIA PROGRESSIVE LENSES TECHNICAL WHITE PAPER UNITY VIA PROGRESSIVE LENSES TECHNICAL WHITE PAPER CONTENTS Introduction...3 Unity Via...5 Unity Via Plus, Unity Via Mobile, and Unity Via Wrap...5 Unity

More information

Scanning Eye Movements in Homonymous Hemianopia Documented by Scanning Laser

Scanning Eye Movements in Homonymous Hemianopia Documented by Scanning Laser Scanning Eye Movements in Homonymous Hemianopia Documented by Scanning Laser Ophthalmoscope Retinal Perimetry. Richard J. Jamara OD, FAAO, Eli Peli MSc, OD, FAAO and Frans Van de Velde MD Department of

More information

BIOGRAPHICAL SKETCH. POSITION TITLE: Professor and Senior Scientist, Moakley Scholar in Aging Eye Research EDUCATION/TRAINING. DEGREE (if applicable)

BIOGRAPHICAL SKETCH. POSITION TITLE: Professor and Senior Scientist, Moakley Scholar in Aging Eye Research EDUCATION/TRAINING. DEGREE (if applicable) OMB No. 0925-0001 and 0925-0002 (Rev. 10/15 Approved Through 10/31/2018) BIOGRAPHICAL SKETCH NAME: Peli, Eli era COMMONS USER NAME: POSITION TITLE: Professor and Senior Scientist, Moakley Scholar in Aging

More information

Yokohama City University lecture INTRODUCTION TO HUMAN VISION Presentation notes 7/10/14

Yokohama City University lecture INTRODUCTION TO HUMAN VISION Presentation notes 7/10/14 Yokohama City University lecture INTRODUCTION TO HUMAN VISION Presentation notes 7/10/14 1. INTRODUCTION TO HUMAN VISION Self introduction Dr. Salmon Northeastern State University, Oklahoma. USA Teach

More information

STUDY OF ADULT STRABISMUS TESTING PROCEDURES MANUAL

STUDY OF ADULT STRABISMUS TESTING PROCEDURES MANUAL STUDY OF ADULT STRABISMUS TESTING PROCEDURES MANUAL Version 3.0 July 13, 2016 SAS1 s Manual_v3.0_7-13-16 1 CONVERGENCE INSUFFICIENCY SYMPTOM SURVEY (CISS)... 3 Convergence Insufficiency Symptom Survey

More information

CASE SERIES. Scanning Eye Movements in Homonymous Hemianopia Documented by Scanning Laser Ophthalmoscope Retinal Perimetry

CASE SERIES. Scanning Eye Movements in Homonymous Hemianopia Documented by Scanning Laser Ophthalmoscope Retinal Perimetry 1040-5488/03/8007-0495/0 VOL. 80, NO. 7, PP. 495 504 OPTOMETRY AND VISION SCIENCE Copyright 2003 American Academy of Optometry CASE SERIES Scanning Eye Movements in Homonymous Hemianopia Documented by

More information

A Checklist for Managing Spectacle Lens Complaints. Presented By: Raymond P. Dennis, M.A. (Ed.) Middlesex Community. Patient Complaints

A Checklist for Managing Spectacle Lens Complaints. Presented By: Raymond P. Dennis, M.A. (Ed.) Middlesex Community. Patient Complaints SPEAKER FINANCIAL DISCLOSURE STATEMENT Raymond P. Dennis has occasionally received honoraria from Essilor of America to present generic continuing education presentations similar to this one. He is a member

More information

Soft CL Multifocals Design and Fitting. Soft Multifocal Lens Designs. Issues Surrounding Multifocals. Blur Interpretation. Simultaneous Vision Designs

Soft CL Multifocals Design and Fitting. Soft Multifocal Lens Designs. Issues Surrounding Multifocals. Blur Interpretation. Simultaneous Vision Designs Soft CL Multifocals Design and Fitting Mark Andre, FAAO Associate Professor of Optometry Pacific University Mark Andre, FAAO is affiliated with CooperVision, as a consultant. Issues Surrounding Multifocals

More information

Lens Types. Single Vision. Lined Bi-Focal. Lined tri-focals

Lens Types. Single Vision. Lined Bi-Focal. Lined tri-focals Lenses It can be helpful to think of very basic lens forms in terms of prisms. As light passes through a prism it is refracted toward the prism base. Minus lenses therefore resemble two prisms apex to

More information

3/31/2016. Presented by: Bob Alexander, ABOM/NCLE-AC Lens Consultant Vision Ease. Everywhere and Sportwrap; Understanding Digital Technology

3/31/2016. Presented by: Bob Alexander, ABOM/NCLE-AC Lens Consultant Vision Ease. Everywhere and Sportwrap; Understanding Digital Technology Everywhere and Sportwrap; Understanding Digital Technology Presented by: Bob Alexander, ABOM/NCLE-AC Lens Consultant Vision Ease Digital - Design and Surfacing VE Digital Designs Optimization Compensation

More information

Eschenbach Low Vision Training Program

Eschenbach Low Vision Training Program Eschenbach Low Vision Training Program Module 5: Magnifying Spectacles Edited by: Thomas Porter, OD Asst. Professor & Director Low Vision Service St. Louis University, Dept. of Ophthalmology 2016 2015

More information

NANOS Patient Brochure

NANOS Patient Brochure NANOS Patient Brochure Homonymous Hemianopia Copyright 2016. North American Neuro-Ophthalmology Society. All rights reserved. These brochures are produced and made available as is without warranty and

More information

DEVELOPMENT AND EVALUATION OF VISION MULTIPLEXING DEVICES FOR VISION IMPAIRMENTS

DEVELOPMENT AND EVALUATION OF VISION MULTIPLEXING DEVICES FOR VISION IMPAIRMENTS International Journal on Artificial Intelligence Tools Vol. 18, No. 3 (2009) 365 378 c World Scientific Publishing Company DEVELOPMENT AND EVALUATION OF VISION MULTIPLEXING DEVICES FOR VISION IMPAIRMENTS

More information

EXTRAOCULAR MUSCLES. Let s get oriented first. Learning Objectives: Extraocular Motility & Cover Testing. Course Title:

EXTRAOCULAR MUSCLES. Let s get oriented first. Learning Objectives: Extraocular Motility & Cover Testing. Course Title: Course Title: Extraocular Motility & Cover Testing Learning Objectives: 1. Identify how to correctly perform the Muscle H test on a patient 2. Know which paired muscles are being tested in each cardinal

More information

Multiple-Choice Questions

Multiple-Choice Questions Multiple-Choice Questions A Board Review Manual 1. A +5.ooD hyperope, with a PD (inter-pupillary distance) of 5 centimeters, is mistakenly given glasses which are decentered outward by 5mm OU. The total

More information

EXAMINATION OF THE CENTRAL VISUAL FIELD AT

EXAMINATION OF THE CENTRAL VISUAL FIELD AT Brit. J. Ophthal. (1968) 52, 408 EXAMINATION OF THE CENTRAL VISUAL FIELD AT A READING DISTANCE*t BY V. N. HIGHMAN Moorfields Eye Hospital, City Road, London THIS investigation was started in an attempt

More information

Collision judgment when viewing minified images through a HMD visual field expander

Collision judgment when viewing minified images through a HMD visual field expander Collision judgment when viewing minified images through a HMD visual field expander Gang Luo, Lee Lichtenstein, Eli Peli Schepens Eye Research Institute Department of Ophthalmology, Harvard Medical School,

More information

G.P. MULTIFOCAL LENSES: A FITTING WORKSHOP

G.P. MULTIFOCAL LENSES: A FITTING WORKSHOP G.P. MULTIFOCAL LENSES: A FITTING WORKSHOP Susan J. Gromacki, OD, MS, FAAO, FSLS Daniel G. Fuller, OD, FAAO, FSLS Cornea, Contact Lenses and Refractive Technologies Section The American Academy of Optometry

More information

Design for Simulator Performance Evaluations of Driving with Vision Impairments and Visual Aids

Design for Simulator Performance Evaluations of Driving with Vision Impairments and Visual Aids Design for Simulator Performance Evaluations of Driving with Vision Impairments and Visual Aids E. Peli, A. R. Bowers, A. J. Mandel, K. Higgins, R. B. Goldstein, and L. Bobrow Driving simulator technology

More information

OPHTHALMIC MATERIALS

OPHTHALMIC MATERIALS Matriculation Number: DEPARTMENT OF VISION SCIENCES SESSION: 2005/2006 DIET: 1ST OPHTHALMIC MATERIALS VISP209 LEVEL 2 MODULE LEADER: DR G WALSH B.Sc./B.Sc. (HONS) OPTOMETRY JANUARY 2006 DURATION: 2HOURS

More information

Neutralizing pattern deviations in

Neutralizing pattern deviations in Brit. J. Ophthal. (I 970) 54, 19 I Neutralizing pattern deviations in ocular motility MARTIN J. URIST From the Motility Clinic of the Illinois Eye and Ear Infirmary, Universitv of Illinois (ollege of Medicine,

More information

IMPLANTABLE MINIATURIZED TELESCOPE (IMT) FOR LOW-VISION

IMPLANTABLE MINIATURIZED TELESCOPE (IMT) FOR LOW-VISION IMPLANTABLE MINIATURIZED TELESCOPE (IMT) FOR LOW-VISION Eli Peli 1, 2, Isaac Lipshitz 2, and Gideon Dotan 2 1 The Schepens Eye Research Institute, Harvard Medical School, Boston MA, USA 2 VisionCare, Inc.,

More information

With unimpaired vision, we enjoy the benefits of a wide

With unimpaired vision, we enjoy the benefits of a wide 1040-5488/02/7909-0569/0 VOL. 79, NO. 9, PP. 569 580 OPTOMETRY AND VISION SCIENCE Copyright 2002 American Academy of Optometry 2001 GLENN A. FRY AWARD LECTURE Treating with Spectacle Lenses: A Novel Idea!?

More information

Bitemporal hemianopia; its unique binocular complexities and a novel remedy

Bitemporal hemianopia; its unique binocular complexities and a novel remedy Ophthalmic & Physiological Optics ISSN 0275-5408 Bitemporal hemianopia; its unique binocular complexities and a novel remedy Eli Peli 1 and PremNandhini Satgunam 2,3 1 Schepens Eye Research Institute,

More information

Custom Solutions Catalog Prescription Corrected Solutions For Your Most Challenging Patients

Custom Solutions Catalog Prescription Corrected Solutions For Your Most Challenging Patients Custom Solutions Catalog Prescription Corrected Solutions For Your Most Challenging Patients Prescription Corrected Eyewear Page 2 Prescription Corrected Filters Page 4 Eschenbach Telescope Mounting Page

More information

Fundamentals of Progressive Lens Design

Fundamentals of Progressive Lens Design Fundamentals of Progressive Lens Design VisionCare Product News Volume 6, Number 9 September 2006 By Darryl Meister, ABOM Progressive Lens Surfaces A progressive addition lens (or PAL ) is a type of multifocal

More information

VARILUX FITTING GUIDE GUIDELINES FOR SUCCESSFULLY FITTING VARILUX LENSES

VARILUX FITTING GUIDE GUIDELINES FOR SUCCESSFULLY FITTING VARILUX LENSES VARILUX FITTING GUIDE GUIDELINES FOR SUCCESSFULLY FITTING VARILUX LENSES WELCOME We are pleased to present this guide which outlines the essential steps for successfully fitting progressive lenses to your

More information

Curriculum Vitae. Computer Vision, Image Processing, Biometrics. Computer Vision, Vision Rehabilitation, Vision Science

Curriculum Vitae. Computer Vision, Image Processing, Biometrics. Computer Vision, Vision Rehabilitation, Vision Science Curriculum Vitae Date Prepared: 01/09/2016 (last updated: 09/12/2016) Name: Shrinivas J. Pundlik Education 07/2002 B.E. (Bachelor of Engineering) Electronics Engineering University of Pune, Pune, India

More information

Special Publication: Ophthalmochirurgie Supplement 2/2009 (Original printed issue available in the German language)

Special Publication: Ophthalmochirurgie Supplement 2/2009 (Original printed issue available in the German language) Special Publication: Ophthalmochirurgie Supplement 2/2009 (Original printed issue available in the German language) LENTIS Mplus - The one -and and-only Non--rotationally Symmetric Multifocal Lens Multi-center

More information

PREMIUM LENSES WITH VARIABLE BASE CURVE

PREMIUM LENSES WITH VARIABLE BASE CURVE PREMIUM LENSES WITH VARIABLE BASE CURVE Inspired by nature - 1 - CONTENT THE ADVANCEMENT OF CAMBER CAMBER TECHNOLOGY Features and Properties Camber Benefits EXPLORING CAMBER LENS SERIES NATURAL NATURAL

More information

The effect of strabismus on object detection in the ring scotoma of a monocular bioptic telescope

The effect of strabismus on object detection in the ring scotoma of a monocular bioptic telescope The effect of strabismus on object detection in the ring scotoma of a monocular bioptic telescope Amy L. Doherty, Alex R. Bowers, Gang Luo, Eli Peli Schepens Eye Research Institute, Mass Eye and Ear, Harvard

More information

THE DESIGN OF DRIVING SIMULATOR PERFORMANCE EVALUATIONS FOR DRIVING WITH VISION IMPAIRMENTS AND VISUAL AIDS

THE DESIGN OF DRIVING SIMULATOR PERFORMANCE EVALUATIONS FOR DRIVING WITH VISION IMPAIRMENTS AND VISUAL AIDS Peli, Bowers, Mandel, Higgins, Goldstein, Bobrow 1 THE DESIGN OF DRIVING SIMULATOR PERFORMANCE EVALUATIONS FOR DRIVING WITH VISION IMPAIRMENTS AND VISUAL AIDS E. Peli, A. R. Bowers, A. J. Mandel, K. Higgins,

More information

The impact of non-immersive head-mounted displays (HMDs) on the visual field

The impact of non-immersive head-mounted displays (HMDs) on the visual field The impact of non-immersive head-mounted displays (HMDs) on the visual field Russell L Woods Ivonne Fetchenheuer Fernando Vargas-Martín Eli Peli Abstract Binocular head-mounted displays (HMDs) that could

More information

ORIGINAL ARTICLE. Torsional Anomalous Retinal Correspondence Effectively Expands the Visual Field in Hemianopia. PremNandhini Satgunam* and Eli Peli

ORIGINAL ARTICLE. Torsional Anomalous Retinal Correspondence Effectively Expands the Visual Field in Hemianopia. PremNandhini Satgunam* and Eli Peli 1040-5488/12/8909-1353/0 VOL. 89, NO. 9, PP. E1353 E1363 OPTOMETRY AND VISION SCIENCE Copyright 2012 American Academy of Optometry ORIGINAL ARTICLE Torsional Anomalous Retinal Correspondence Effectively

More information

Slab Off or Bicentric Grinding

Slab Off or Bicentric Grinding Slab Off or Bicentric Grinding What is This? A slab-off is a technique in which base-up prism is ground on lower half of the lens in either the most minus or least plus. The finished product looks as if

More information

THRESHOLD AMSLER GRID TESTING AND RESERVING POWER OF THE POTIC NERVE by MOUSTAFA KAMAL NASSAR. M.D. MENOFIA UNIVERSITY.

THRESHOLD AMSLER GRID TESTING AND RESERVING POWER OF THE POTIC NERVE by MOUSTAFA KAMAL NASSAR. M.D. MENOFIA UNIVERSITY. THRESHOLD AMSLER GRID TESTING AND RESERVING POWER OF THE POTIC NERVE by MOUSTAFA KAMAL NASSAR. M.D. MENOFIA UNIVERSITY. Since Amsler grid testing was introduced by Dr Marc Amsler on 1947and up till now,

More information

Patients in your area are ready to set appointments with you. Keep reading on to learn why they re eager to use our system.

Patients in your area are ready to set appointments with you. Keep reading on to learn why they re eager to use our system. Hello Doctor! If you re reading this, the person who gave it to you is one of over 11,000 people who visited our website looking for a provider of Vivid Vision - Vision Therapy in Virtual Reality. They

More information

Author: Ida Lucy Iacobucci, 2015

Author: Ida Lucy Iacobucci, 2015 Author: Ida Lucy Iacobucci, 2015 License: Unless otherwise noted, this material is made available under the terms of the Creative Commons Attribution-NonCommercial-Share Alike 4.0 License: http://creativecommons.org/licenses/by-nc-sa/4.0/

More information

Auditory Biofeedback to Control Vertical and Horizontal Eye Movements in the Dark

Auditory Biofeedback to Control Vertical and Horizontal Eye Movements in the Dark Investigative Ophthalmology & Visual Science, Vol. 29, No. 12, December 1988 Copyright Association for Research in Vision and Ophthalmology Auditory Biofeedback to Control Vertical and Horizontal Eye Movements

More information

Where s my lens clock? Where s the base curve? F1 (front) or F2 (back) surface? Red or black scale?

Where s my lens clock? Where s the base curve? F1 (front) or F2 (back) surface? Red or black scale? As a paid speaker I have not been sponsored by any companies mentioned in this lecture I am not a consultant to nor an employee of any ophthalmic company. Robert Lee, OD Western University College of Optometry

More information

Varilux Comfort. Technology. 2. Development concept for a new lens generation

Varilux Comfort. Technology. 2. Development concept for a new lens generation Dipl.-Phys. Werner Köppen, Charenton/France 2. Development concept for a new lens generation In depth analysis and research does however show that there is still noticeable potential for developing progresive

More information

Concepts of Optics Quiz. 8. Spherical lenses focus along a single point; cylindrical lenses focus along a.

Concepts of Optics Quiz. 8. Spherical lenses focus along a single point; cylindrical lenses focus along a. Concepts of Optics Quiz 1. Prisms bend light from (apex/base) to (apex/base). 2. Prisms displace images in the direction of the (apex/base). 3. A (plus/minus) lens is convex. 4. A (plus/minus) lens diverges

More information

Wide-Band Enhancement of TV Images for the Visually Impaired

Wide-Band Enhancement of TV Images for the Visually Impaired Wide-Band Enhancement of TV Images for the Visually Impaired E. Peli, R.B. Goldstein, R.L. Woods, J.H. Kim, Y.Yitzhaky Schepens Eye Research Institute, Harvard Medical School, Boston, MA Association for

More information

HOW WE LL PROCEED. I ll put up a statement. You guess the answer Yes no True-false. You Focus the Lensometer Using the Target Circles.

HOW WE LL PROCEED. I ll put up a statement. You guess the answer Yes no True-false. You Focus the Lensometer Using the Target Circles. HOW WE LL PROCEED I ll put up a statement Lensometers Don t Read Power Ed De Gennaro Midlothian, Virginia OPTICAL MYTHS, HALF TRUTHS AND FALSEHOODS You guess the answer Yes no True-false True! HOW A LENSOMETER

More information

3/6/2014. Because: Answer: Early studies comparing acuity with spectacles vs. scl or rigid cl s

3/6/2014. Because: Answer: Early studies comparing acuity with spectacles vs. scl or rigid cl s IAO/COS March 7, 2014 Peter Russo, OD, FAAO Professor Department of Ophthalmology Loyola University Medical Center Edward Hines Jr. VAMC No financial disclosures. We don t; we just look better in CL s.

More information

The people-based design

The people-based design The people-based design InnoVision HOYA Vision Care Company always strives to develop new calculation techniques and optimisation methods that leads to the development of smarter lens designs. To enhance

More information

Heads you win, tails you lose

Heads you win, tails you lose 4 dispensingoptics September 2014 Heads you win, tails you lose By Andrew Keirl BOptom (Hons) MCOptom FBDO CompetencIes covered: Dispensing opticians: Ocular Examination, Contact Lenses, efractive Management

More information

SPHERE, CYLINDER, AXIS, and ADD Power: Why these four variables? Example Prescriptions: UNDERSTANDING A PRESCRIPTION SPHERICAL LENSES 8/31/2018

SPHERE, CYLINDER, AXIS, and ADD Power: Why these four variables? Example Prescriptions: UNDERSTANDING A PRESCRIPTION SPHERICAL LENSES 8/31/2018 8/31/2018 UNDERSTANDING A PRESCRIPTION Speaker: Michael Patrick Coleman, COT & ABOC SPHERE, CYLINDER, AXIS, and ADD Power: Why these four variables? Example Prescriptions: +2.50 SPH Simple SPHERICAL Rx

More information

Human Senses : Vision week 11 Dr. Belal Gharaibeh

Human Senses : Vision week 11 Dr. Belal Gharaibeh Human Senses : Vision week 11 Dr. Belal Gharaibeh 1 Body senses Seeing Hearing Smelling Tasting Touching Posture of body limbs (Kinesthetic) Motion (Vestibular ) 2 Kinesthetic Perception of stimuli relating

More information

A reduction of visual fields during changes in the background image such as while driving a car and looking in the rearview mirror

A reduction of visual fields during changes in the background image such as while driving a car and looking in the rearview mirror Original Contribution Kitasato Med J 2012; 42: 138-142 A reduction of visual fields during changes in the background image such as while driving a car and looking in the rearview mirror Tomoya Handa Department

More information

WEARABLE WIRELESS ADAPTIVE REFRACTOR

WEARABLE WIRELESS ADAPTIVE REFRACTOR B H WEARABLE WIRELESS ADAPTIVE REFRACTOR REVOLUTIONIZING SUBJECTIVE REFRACTION A vision that inspires yours REVOLUTIONIZING THE MEASUREMENT OF SUBJECTIVE REFRACTION VisionFit is an innovative electronic,

More information

Novel 3D Computerized Threshold Amsler Grid Test CA, USA

Novel 3D Computerized Threshold Amsler Grid Test CA, USA Novel 3D Computerized Threshold Amsler Grid Test Wolfgang Fink 1,2 and Alfredo A. Sadun 2 1 California Institute of Technology, Pasadena, CA, USA 2 Doheny Eye Institute, Keck School of Medicine, University

More information

Physiology of Vision The Eye as a Sense Organ. Rodolfo T. Rafael,M.D. Topics

Physiology of Vision The Eye as a Sense Organ. Rodolfo T. Rafael,M.D. Topics Physiology of Vision The Eye as a Sense Organ Rodolfo T. Rafael,M.D. www.clinicacayanga.dailyhealthupdates.com 1 Topics Perception of Light Perception of Color Visual Fields Perception of Movements of

More information

PERIMETRY A STANDARD TEST IN OPHTHALMOLOGY

PERIMETRY A STANDARD TEST IN OPHTHALMOLOGY 7 CHAPTER 2 WHAT IS PERIMETRY? INTRODUCTION PERIMETRY A STANDARD TEST IN OPHTHALMOLOGY Perimetry is a standard method used in ophthalmol- It provides a measure of the patient s visual function - performed

More information

Prosthetic Contact Lenses

Prosthetic Contact Lenses Prosthetic Contact Lenses Marsha M. Malooley, OD, FAAO Please silence all mobile devices and remove items from chairs so others can sit. Unauthorized recording of this session is prohibited. Disclosure

More information

continuing education course Approved by the American Board of Opticianry

continuing education course Approved by the American Board of Opticianry continuing education course Approved by the American Board of Opticianry Average Math for the Above Average Dispenser National Academy of Opticianry 8401 Corporate Drive #605 Landover, MD 20785 800-229-4828

More information

Spatial perception and progressive addition lenses

Spatial perception and progressive addition lenses Spatial perception and progressive addition lenses Peter Leslie Hendicott DipAppSc(Optom), MAppSc School of Optometry Queensland University of Technology Brisbane Australia A thesis in fulfillment of the

More information

Fitting Manual Use with kerasofttraining.com

Fitting Manual Use with kerasofttraining.com Fitting Manual Use with Fitting Manual: Contents This fitting manual is best used in conjunction with KeraSoft IC online training. To register, please visit www. 01 Kerasoft IC Design - Outlines the KeraSoft

More information

KODAK Unique DRO Progressive Lens BE UNIQUE IN YOUR MODERN WORLD

KODAK Unique DRO Progressive Lens BE UNIQUE IN YOUR MODERN WORLD KODAK Unique DRO Progressive Lens BE UNIQUE IN YOUR MODERN WORLD NEW TECHNOLOGY UP CLOSE AND CLEAR Receive a fully-reinforced, reading area. KODAK Unique DRO Lens delivers a new level of near viewing with

More information

Optics. Experiment #4

Optics. Experiment #4 Optics Experiment #4 NOTE: For submitting the report on this laboratory session you will need a report booklet of the type that can be purchased at the McGill Bookstore. The material of the course that

More information

Retinally-induced aniseikonia

Retinally-induced aniseikonia Retinally-induced aniseikonia G.C. de Wit, Ph.D. Optical Diagnostics, Eikvaren 19, 4102 XE Culemborg, The Netherlands Abstract Purpose: To show that retinally-induced aniseikonia may vary as a function

More information

DEFECTS OF VISION THROUGH APHAKIC SPECTACLE LENSES*t

DEFECTS OF VISION THROUGH APHAKIC SPECTACLE LENSES*t Brit. J. Ophthal. (1967) 51, 306 DEFECTS OF VISION THROUGH APHAKIC SPECTACLE LENSES*t BY ROBERT C. WELSH Miami, Florida BY the use of a series of scale diagrams an attempt is made to explain the following:

More information

An Interesting Use of Bausch and Lomb s KeraSoft IC Lens

An Interesting Use of Bausch and Lomb s KeraSoft IC Lens An Interesting Use of Bausch and Lomb s KeraSoft IC Lens Nate Schlotthauer, OD 2012 Michigan College of Optometry Cornea and Contact Lens Resident Introduction: The KeraSoft IC lens, introduced to the

More information

A New Method for Estimating Effects of Visual Field Loss in a Panoramic Driving Environment

A New Method for Estimating Effects of Visual Field Loss in a Panoramic Driving Environment University of Iowa Iowa Research Online Driving Assessment Conference 2017 Driving Assessment Conference Jun 27th, 12:00 AM A New Method for Estimating Effects of Visual Field Loss in a Panoramic Driving

More information

Fax: (800) Phone: (800) Fax: (800)

Fax: (800) Phone: (800) Fax: (800) Fax: (800)628-9819 Phone: (800)525-1274 Fax: (800)628-9819 www.laramyk.com Calculation Technologies Laramy-k is proud to offer the most flexible solution with the possibility to access all the different

More information

CERTIFICATE IN DISPENSING OPTICS (CDO) Term-End Examination June, 2015

CERTIFICATE IN DISPENSING OPTICS (CDO) Term-End Examination June, 2015 No. of Printed Pages : 8 OAH-005 CERTIFICATE IN DISPENSING OPTICS (CDO) Term-End Examination June, 2015 OAH-005 : PROGRESSIVE LENS Time : 90 Minutes Maximum Marks : 30 Note : (i) (ii) (iii) (iv) There

More information

Information Guide. Synoptophore (Major Amblyoscope) Heading. Body copy. Body copy bold

Information Guide. Synoptophore (Major Amblyoscope) Heading. Body copy. Body copy bold Information Guide Heading Body copy Body copy bold Synoptophore (Major Amblyoscope) Synoptophore (sin-op-to-phore) Greek: syn = with, ops = eye, phoros = bearing Introduction This information has been

More information

Low Vision Math Made Easy for the Primary Care Optometrist

Low Vision Math Made Easy for the Primary Care Optometrist Low Vision Math Made Easy for the Primary Care Optometrist Karl Citek, OD, PhD, FAAO I. Introduction Case Example Esther, 82 yowf, AMD OS>OD, referral from another ECP Habitual Rx: OD +1.25-1.00 x030 OS

More information

Chapter 3: LENS FORM Sphere

Chapter 3: LENS FORM Sphere Chapter 3: LENS FORM Sphere It can be helpful to think of very basic lens forms in terms of prisms. Recall, as light passes through a prism it is refracted toward the prism base. Minus lenses therefore

More information

12.1. Human Perception of Light. Perceiving Light

12.1. Human Perception of Light. Perceiving Light 12.1 Human Perception of Light Here is a summary of what you will learn in this section: Focussing of light in your eye is accomplished by the cornea, the lens, and the fluids contained in your eye. Light

More information

This article reprinted from: Linsenmeier, R. A. and R. W. Ellington Visual sensory physiology.

This article reprinted from: Linsenmeier, R. A. and R. W. Ellington Visual sensory physiology. This article reprinted from: Linsenmeier, R. A. and R. W. Ellington. 2007. Visual sensory physiology. Pages 311-318, in Tested Studies for Laboratory Teaching, Volume 28 (M.A. O'Donnell, Editor). Proceedings

More information

Diabetic Retinopathy Clinical Research Network (DRCR.net) UWF Optos 200Tx Imaging Protocol. Version 3.0 9/19/16

Diabetic Retinopathy Clinical Research Network (DRCR.net) UWF Optos 200Tx Imaging Protocol. Version 3.0 9/19/16 Diabetic Retinopathy Clinical Research Network (DRCR.net) UWF Optos 200Tx Imaging Protocol Version 3.0 9/19/16 DRCR.net UWF 200 Tx Imaging Protocol V3.0 9-19-15 Final Page 1 of 14 Table of Contents Background...

More information

THE SCHOOL BUS. Figure 1

THE SCHOOL BUS. Figure 1 THE SCHOOL BUS Federal Motor Vehicle Safety Standards (FMVSS) 571.111 Standard 111 provides the requirements for rear view mirror systems for road vehicles, including the school bus in the US. The Standards

More information

Fast and accurate vestibular testing

Fast and accurate vestibular testing Fast and accurate vestibular testing Next-generation vestibular testing The ICS Chartr 200 system is the latest generation of our well-known vestibular test systems. ICS Chartr 200 provides you with a

More information

3D Space Perception. (aka Depth Perception)

3D Space Perception. (aka Depth Perception) 3D Space Perception (aka Depth Perception) 3D Space Perception The flat retinal image problem: How do we reconstruct 3D-space from 2D image? What information is available to support this process? Interaction

More information

2008 Hoya Grant & Scholarship Wining Case Study

2008 Hoya Grant & Scholarship Wining Case Study 2008 Hoya Grant & Scholarship Wining Case Study Progressive Lens Technology and the Implications for Struggling Presbyopes with Peripheral Distortion and Blur: A Case Study Andrew M. Graves 3 rd Year Optometry

More information

LENSES. Materials, Types and Treatments. Mary E. Schmidt, ABOC, CPO

LENSES. Materials, Types and Treatments.  Mary E. Schmidt, ABOC, CPO LENSES Materials, Types and Treatments www.eyesystems.info Mary E. Schmidt, ABOC, CPO mary@eyesystems.info Single Vision Spherical in design All purpose, single focus, may be sphere or cylinder Rx s Aspheric

More information

20 Staniford Street, Boston MA 340 Putnam Avenue, Cambridge MA

20 Staniford Street, Boston MA 340 Putnam Avenue, Cambridge MA Curriculum Vitae Date Prepared: May 22, 2014 Name: Office Address: Home Address: Matteo Tomasi Work Phone: 617-912-2587 Work Email: Work FAX: 617-912-0112 Place of Birth: 20 Staniford Street, 02114 Boston

More information

LENSES. Materials, Types and Treatments. Single Vision. Aspherical Lens Forms

LENSES. Materials, Types and Treatments. Single Vision. Aspherical Lens Forms LENSES Materials, Types and Treatments www.eyesystems.info Mary E. Schmidt, ABOC, CPO mary@eyesystems.info Single Vision Spherical in design All purpose, single focus, may be sphere or cylinder Rx s Aspheric

More information

Such explanations do not take into account other environmental factors, such as a bad diet or poor. Causes:

Such explanations do not take into account other environmental factors, such as a bad diet or poor. Causes: Myopia (nearsightedness) Myopia is a name used to describe the refractive disorder known as nearsightedness. With nearsightedness, light rays from nearby objects focus on the retina, but distant objects

More information

ABO Certification Training. Part I: Anatomy and Physiology

ABO Certification Training. Part I: Anatomy and Physiology ABO Certification Training Part I: Anatomy and Physiology Major Ocular Structures Centralis Nerve Major Ocular Structures The Cornea Cornea Layers Epithelium Highly regenerative: Cells reproduce so rapidly

More information

Vision Science I Exam 2 31 October 2016

Vision Science I Exam 2 31 October 2016 Vision Science I Exam 2 31 October 2016 1) Mr. Jack O Lantern, pictured here, had an unfortunate accident that has caused brain damage, resulting in unequal pupil sizes. Specifically, the right eye is

More information

Chapter 6. Experiment 3. Motion sickness and vection with normal and blurred optokinetic stimuli

Chapter 6. Experiment 3. Motion sickness and vection with normal and blurred optokinetic stimuli Chapter 6. Experiment 3. Motion sickness and vection with normal and blurred optokinetic stimuli 6.1 Introduction Chapters 4 and 5 have shown that motion sickness and vection can be manipulated separately

More information

Driver Education Classroom and In-Car Curriculum Unit 3 Space Management System

Driver Education Classroom and In-Car Curriculum Unit 3 Space Management System Driver Education Classroom and In-Car Curriculum Unit 3 Space Management System Driver Education Classroom and In-Car Instruction Unit 3-2 Unit Introduction Unit 3 will introduce operator procedural and

More information

The MoviText method: Efficient pre-optical reading training in persons with central visual field loss

The MoviText method: Efficient pre-optical reading training in persons with central visual field loss Technology and Disability 6 (2004) 211 221 211 IOS Press The MoviText method: Efficient pre-optical reading training in persons with central visual field loss Jögen Gustafsson and Krister Inde Division

More information

Diabetic Retinopathy Clinical Research Network (DRCR.net) UWF Optos Imaging Protocol. Version /14/14

Diabetic Retinopathy Clinical Research Network (DRCR.net) UWF Optos Imaging Protocol. Version /14/14 Diabetic Retinopathy Clinical Research Network (DRCR.net) UWF Optos Imaging Protocol Version 1.0 10/14/14 DRCR.net UWF Imaging Protocol FINAL 10-14-14 Page 1 of 14 Table of Contents Background... 3 P200Tx

More information

055_056_varilux_divider.indd 55 VARILUX VARILUX

055_056_varilux_divider.indd 55 VARILUX VARILUX 055_056_varilux_divider.indd 55 VARILUX VARILUX 26/02/13 16:53 055_056_varilux_divider.indd 56 26/02/13 16:53 VARILUX RANGE Natural vision Ultimate vision Varilux S2 Varilux S Design Wider angle of vision

More information

Low Vision Assessment Components Job Aid 1

Low Vision Assessment Components Job Aid 1 Low Vision Assessment Components Job Aid 1 Eye Dominance Often called eye dominance, eyedness, or seeing through the eye, is the tendency to prefer visual input a particular eye. It is similar to the laterality

More information

What s a Corneal GP Lens?

What s a Corneal GP Lens? Slide 1 What s a Corneal GP Lens? Richard Dorer NCLEC Blanchard Contact Lens Inc. 800-367-4009 x 131 richarddorer@gmail.com www.blanchardlab.com Slide 2 Endorsements I am a paid representative and consultant

More information