Intraoperative stereoscopic QuickTime Virtual Reality

Size: px
Start display at page:

Download "Intraoperative stereoscopic QuickTime Virtual Reality"

Transcription

1 See the Editorial and the Response in this issue, pp J Neurosurg 100: , 2004 Intraoperative stereoscopic QuickTime Virtual Reality ATTILA BALOGH, M.D., MARK C. PREUL, M.D., MARK SCHORNAK, M.S., MICHAEL HICKMAN, B.F.A., AND ROBERT F. SPETZLER, M.D. Division of Neurological Surgery and Neuroscience Publications, Barrow Neurological Institute, St. Joseph s Hospital and Medical Center, Phoenix, Arizona Object. The aim of this study was to acquire intraoperative images during neurosurgical procedures for later reconstruction into a stereoscopic image system (QuickTime Virtual Reality [QTVR]) that would improve visualization of complex neurosurgical procedures. Methods. A robotic microscope and digital cameras were used to acquire left and right image pairs during cranial surgery; a grid system facilitated image acquisition with the microscope. The surgeon determined a field of interest and a target or pivot point for image acquisition. Images were processed with commercially available software and hardware. Two-dimensional (2D) or interlaced left and right 2D images were reconstructed into a standard or stereoscopic QTVR format. Standard QTVR images were produced if stereoscopy was not needed. Intraoperative image sequences of regions of interest were captured in six patients. Relatively wide and deep dissections afford an opportunity for excellent QTVR production. Narrow or restricted surgical corridors can be reconstructed into the stereoscopic QTVR mode by using a keyhole mode of image acquisition. The stereoscopic effect is unimpressive with shallow or cortical surface dissections, which can be reconstructed into standard QTVR images. Conclusions. The QTVR system depicts multiple views of the same anatomy from different angles. By tilting, panning, or rotating the reconstructed images, the user can view a virtual three-dimensional tour of a neurosurgical dissection, with images acquired intraoperatively. The stereoscopic QTVR format provides depth to the montage. The system recreates the dissection environment almost completely and provides a superior anatomical frame of reference compared with the images captured by still or video photography in the operating room. KEY WORDS QuickTime Virtual Reality stereoscopy neurosurgical simulation surgical anatomy computer-aided learning neurosurgical education I NTRAOPERATIVE images captured through an operating microscope often leave viewers who were not present during surgery with an unsatisfactory experience. This situation involves several issues, as follows: 1) 2D images; 2) limited depth of field of the images, showing little of the surrounding anatomy; 3) a limited area in focus; and 4) user-passive images (that is, they are not incorporated into a software system that enables viewer-defined navigation). Consequently, the information is suboptimal for the purposes of education, review, and presentation. We have previously described a system that captures approach-based sequential images from exquisite laboratory cadaveric dissections and displays them using QTVR (Apple Computer, Inc., Cupertino, CA) in standard and stereoscopic mode. 9 As with standard QTVR, the images are captured and processed so that the user can later interact with and control the display of the surrounding environment (in this case anatomy) by panning (moving left to right) and tilting (moving up and down). The previously described stereoscopic image system improves visualization of complex neuroanatomy and permits Abbreviations used in this paper: CA = carotid artery; QTVR = QuickTime Virtual Reality; 2D = two-dimensional; 3D = three-dimensional. more complete review and use of laboratory cadaveric dissections. Consequently, we sought to expand the system to take advantage of useful time-sensitive image information available from the operating room. In this report we describe the intraoperative use of this system to capture and display images obtained in neurosurgical cases by using standard and stereoscopic QTVR modes. Technical Components After a disease structure had been identified or the region of interest had been dissected and hemostasis had been achieved during surgery, the operating microscope (model NC4; Carl Zeiss Surgical, Inc., Thornwood, NY) was replaced with a robotic microscope (Zeiss MKM carrier with OPMI neurosurgical microscope; Carl Zeiss Surgical, Inc.) equipped with two digital cameras (EOS D60; Canon, Inc., Tokyo, Japan) that were attached to the sidearms of the microscope to capture intraoperative images simultaneously. A grid system established to facilitate image acquisition with the Zeiss MKM microscope allowed convenient QTVR acquisition. Two points that corresponded to the two extreme angled positions in the operative field of interest were identified. Usually a midpoint between these extremes was chosen as the QTVR target point. The senior author (R.F.S.) determined the field of interest and set the target J. Neurosurg. / Volume 100 / April,

2 A. Balogh, et al. FIG. 1. Montage showing the method of inverted cone image acquisition. The tip of the cone is the pivot point, and the anatomical target is at the center of the grid. point for acquiring the QTVR image. The size of the grid was changed by entering the number of the horizontal and vertical steps between the two locations. Each step of the grid represented the position to which the microscope would automatically move. Microscope pivot points were established using two methods. In one method a targeted structure or a low point in the dissection was used as the pivot point (for example, the bottom of an inverted cone; Fig. 1). This method was used for large, wide, and deep exposures. In the other (keyhole) method, the pivot point was above the target structure, but structures below the pivot point were still imaged (Fig. 2). This method was used in dissections with a narrow corridor. Regardless of the pivot points, images were acquired in focus by using the microscope s autofocus function. Two images were captured from footage shot by both cameras at each position for the left and right eyepieces. Simultaneous right and left images were acquired using two remote control devices. The vertical and horizontal extent of angulation from the focal point was approximately 45. The number of pictures captured in the grid was predefined by the number of points set into it indicating that an image would be obtained. Thus, the navigation experience became smoother as more images were obtained. Acquisition time, however, lengthened as the number of images acquired increased, because it took longer for the microscope to move through the grid. Each camera was equipped with a 10-GB microdrive (IBM Storage Systems Division, San Jose, CA) for image storage. Image Processing Images were processed to produce a standard or stereoscopic QTVR recording. Both types of image sets were usually produced. Producing Standard QTVR Images Images were processed with commercially available software and hardware. Images stored on the microdrives were downloaded to a graphics workstation by using Canon software drivers. Left and right images were archived in separate folders for later processing to a smaller size in Adobe Photoshop (Adobe Systems, Inc., San Jose, CA). The VR Worx program (VR Toolbox, Inc., Pittsburgh, PA) was used to reconstruct the image acquisition grid from the Zeiss MKM microscope on the graphics workstation. Images were loaded into the grid to match each point at which they were originally set; the Zeiss MKM QTVR acquisition software was used for this purpose. The VR Worx program was used to construct the QTVR image, which can be made using all of the left or right eyepiece images. Producing Stereoscopic QTVR Images Three-dimensional software (Stereo Image Factory Plus; SOFTreat Co., Raleigh, NC) was used to produce and align corresponding interlaced left and right image pairs. The interlaced pictures were archived in separate folders and loaded into the recreated grid with the aid of VR Worx. The final product was an interlaced QTVR image that could be viewed with synchronized liquid crystal display shutter glasses (VR Visualizer; Vrex, Inc., Elmsford, NY) or with a projector system equipped with polarized lenses to produce the stereoscopic effect. The shutter glasses used to connect the computer workstation and monitor require no specialized additions to the workstation such as graphic cards or software. Illustrative Cases Three cases illustrate the benefits and limitations of the standard and stereoscopic QTVR systems. 592 J. Neurosurg. / Volume 100 / April, 2004

3 Intraoperative stereoscopic QuickTime Virtual Reality FIG. 2. Montage showing the keyhole method of image acquisition. The pivot point is above the target anatomy, providing views of structures that would be hidden while using the inverted cone method. Case 1. This 54-year-old woman underwent a right orbitozygomatic approach to clip an aneurysm involving the right middle cerebral artery. The focus/pivot point for the QTVR image acquisition was the bifurcation of the CA. The images were acquired using the inverted cone method. The grid size was seven seven frames, yielding 49 images acquired over 20 minutes. Angulation was approximately 45 horizontally and vertically (Fig. 3). Case 2. This 70-year-old man underwent a transcallosal approach to resect a colloid cyst of the third ventricle. The pivot point was set to the level of the small craniotomy, and the images were acquired using the keyhole method. The grid size was six six frames, yielding 36 images acquired over 15 minutes. Angulation was approximately 45 horizontally and vertically (Fig. 4). Case 3. This 53-year-old man underwent a frontotemporal craniotomy to resect a mycotic aneurysm on the right distal middle cerebral artery on the cerebral surface. The pivot point for the QTVR image acquisition was the cerebral surface near the aneurysm. The grid size was seven seven frames, yielding 49 images acquired over 20 minutes. Angulation was approximately 45 horizontally and vertically (Fig. 5). Discussion Neurosurgeons routinely capture images during surgery. Most of these images are still photographs acquired with or without the aid of an operating microscope. The photographic and illustrative works of Harvey Cushing and Mildred Codding, 3 Dorcas Hager Padget and Walter Dandy, 6 Charles P. Hodge and Wilder Penfield, 10 and Albert L. Rhoton Jr. 17 serve as a testament to the efforts of neurosurgeons to communicate visually about their anatomical and surgical encounters in the operating room. Advances in photographic technology are increasing the number of images acquired in digital still formats. 15 Small video cameras that FIG. 3. Montage showing two enlarged images from within the grid system that reveal the surgical anatomy from different angles as the user pans horizontally or tilts up and down. The bifurcation of the right CA seen from a variety of angles reveals structures that may be hidden (for example, the CA bifurcation and its perforating vessels) in certain views. J. Neurosurg. / Volume 100 / April,

4 A. Balogh, et al. FIG. 5. Montage demonstrating that the lack of depth in the field (for example, when treating a lesion on the surface of the brain) provides no additional valuable information. Therefore, the standard QTVR mode is sufficient. FIG. 4. Montage demonstrating that, with the pivot point at the level of the craniotomy, the keyhole function allows images to be captured through a narrow corridor (for example, in a minicraniotomy or a transcallosal approach). The keyhole mode permits views of anatomical features that are obstructed and that otherwise would be visible only through a larger craniotomy. can mount on the operating microscope are also available. Although images may be played repetitively to review a case, the images or video sequences are limited by the restricted depth of field: only the target anatomy or lesion is in focus. Furthermore, the user cannot navigate through the image. The term QTVR refers to an image reconstruction method that is relatively independent of computer platforms. Multiple 2D or interlaced 2D images from an object that are acquired from slightly different angles are reconstructed into a single image montage by using commercially available software. The application of QTVR to medicine is quickly being recognized. 2,12,13,16 Interlacing of the images acquired from slightly different angles produces a sense of depth a stereoscopic effect. The stereoscopic QTVR system we have described allows the user to navigate through a depthenhanced montage with readily available, affordable computer hardware and software. Although the stereoscopic QTVR mode is not based on true 3D renderings, the image acquisition mode from two different eyepieces creates a stereoscopic display of the images. As a result, users can look behind or around structures in the field of interest by using a mouse or keyboard to pan, tilt, and rotate the reconstructed image. This system provides unique educational opportunities for its users, who can visualize target anatomical images acquired during live surgery within a more complete anatomical frame of reference than is offered by any other modality. With the aid of the stereoscopic shutter glasses, the intraoperative anatomy sequences can be readily combined for presentation or for review on standard personal computer workstations. If the user prefers it or lacks the hardware for stereoscopic viewing, the images can also be viewed in the standard QTVR format. The captured segments are easily distributed to storage media or embedded into internet web pages. We have used two methods to produce stereoscopic QTVR images. The first is produced around a fixed focal point. Conceptually, the focal point is like the tip of an inverted cone. This method is applied when the dissection environment is wide and deep (for example, orbitozygomatic exposure, far-lateral craniotomy, transfacial approaches, or approaches to the interpeduncular fossa associated with many small, important structures). The second method uses an external focal point located slightly above the bottom of the dissection (keyhole mode). As the viewer pans or tilts in one direction, a view of otherwise hidden structures can be achieved in the opposite direction by using the QTVR system (Fig. 6). This method especially affords views of structures that are otherwise partially obstructed or hidden and offers better views of the anatomy in narrower or restricted 594 J. Neurosurg. / Volume 100 / April, 2004

5 Intraoperative stereoscopic QuickTime Virtual Reality settings. Images obtained from the surface of the brain, as in Case 3, do not produce the striking 3D effect in the stereoscopic QTVR mode because depth of field is lacking. In such situations, the standard QTVR mode is a better option. Although the cameras, computer hardware and software, and visualization hardware (shutter glasses) are convenient and readily available, the robotic microscope system used as the platform is not. Few microscopes produced for the operating room are robotic or have automated control for such image acquisition. We use the model MKM microscope (Carl Zeiss Surgical, Inc.), which is well suited to this work because it can be controlled robotically and more precisely with specialized operational software. 2 The experience of seeing depictions of live anatomy acquired during surgery through a system producing stereoscopic images is exhilarating. The experience is further enhanced by the user s ability to define the orientation. Archived material combined with such image reconstruction has even greater heuristic value. Optimally, instead of splicing digital still images into a stereoscopic QTVR segment, images acquired with high-definition stereo video cameras while a continuous, smooth, automatic movement of the microscope is being executed would substantially decrease image acquisition time. This method would also provide an incredibly smooth interactive stereoscopic QTVR experience. Although there are indications that such virtual or semivirtual environment systems have educational benefits, most have not yet been widely evaluated. 1,7,19 The unanimous statements by our residents and fellows that they now have a better understanding of the anatomical relationships at least indicates that they enjoy lectures and presentations with immersive 3D content. Because we have based our software and hardware on widely available technology, 4 the educational value of such a system is amenable to evaluation. It will be incumbent on neurosurgeons to establish the educational value and benefit of these systems for training and continuing medical education. 5,8 The motivations are strong: opportunities for neurosurgical trainees to learn based on practical anatomy or the relatively unrestricted or legally unfettered surgical experience of previous generations may be waning. We believe that this and similar technology is workable and meaningful. Because neurosurgical trainees are restricted to 80-hour work weeks, along with subsequent maintenance of certification, this type of anatomical data display will be vital in both training and assessment of competency. Furthermore, impending legislation may restrict cadaver donations and substantially increase the already high cost of obtaining and maintaining cadaveric specimens. Such developments would adversely affect opportunities to practice surgical dissection in the laboratory. A fully simulated environment that mimics reality is still difficult to produce. 18 Most virtual systems require complex proprietary software or hardware. We have tended to remain within the realm of portraying real anatomy in reconstructed 3D or stereoscopic mode. Nevertheless, we are in the process of combining other technologies with stereoscopic imaging to obtain realistic representations of scenarios that cannot be seen using conventional photography or video recording. In the past 5 years, references to virtual systems have increased considerably. 18 We are combining J. Neurosurg. / Volume 100 / April, 2004 FIG. 6. Images demonstrating the two QTVR modes. A: The inverted cone method offers a limited field of view for image acquisition through a narrow surgical corridor. B: The keyhole method provides the entire field of view for image acquisition and 3D image reconstruction through the same narrow surgical corridor. This view would otherwise only be visible through a larger exposure. advances in computer technology, image processing, highfidelity rendering, haptics, sensors, and optics that may also lead to virtual neurosurgery for rehearsal and training purposes. Obtaining images for stereoscopic QTVR production in every surgical case by switching to a robotically controlled operating microscope is not feasible in today s cost- and time-conscious operating room. Nevertheless, creating an experience with depth, perspective, and user navigation from the real image content of an exquisite operation performed by a master surgeon offers a potentially valuable learning experience. Moreover, using cross-platform software and a standard computer workstation or laptop computer allows this imaging modality to become widely and conveniently available. 4 As the surgical microscope evolves and becomes a platform to which the surgeon may be connected only remotely (for example, becoming an imaging tool that delivers oriented images to the surgeon s goggles), advances will allow 3D or stereoscopic images to be captured in unique and increasingly practical ways. 14 Undoubtedly, various technologies will combine to produce fully immersive, real-time multisensory fusion of real and virtual information data streams into online, real-time visualizations recorded from actual neurosurgical procedures. 11,18 Such technology would permit 3D imaging of surgery for virtual reality-based education the creation of stereoscopic experiences that include the maneuvers of the surgeon or recordings made during the emergence of surgical problems that are expertly managed. Acknowledgments We thank Carl Zeiss Surgical, Inc., for providing the MKM operating microscope hardware and software support for this project. We also acknowledge Dr. Jeff Henn, a former resident at the Barrow Neurological Institute who is currently at the University of Florida in 595

6 A. Balogh, et al. Gainesville, for the original idea and development of microscopic stereo QTVR. References 1. Anastakis DJ, Regehr G, Reznick RK, et al: Assessment of technical skills transfer from the bench training model to the human model. Am J Surg 177: , Bernardo A, Preul MC, Zabramski JM, et al: A three-dimensional interactive virtual dissection model to simulate transpetrous surgical avenues. Neurosurgery 52: , Black PM, Moore MR, Rossitch E Jr: The Surgical Art of Harvey Cushing. Park Ridge, IL: American Association of Neurological Surgeons, Bullitt E, Aylward S, Bernard EJ Jr, et al: Computer-assisted visualization of arteriovenous malformations on the home personal computer. Neurosurgery 48: , Cusimano MD: Virtual reality surgery: neurosurgery and the contemporary landscape a three dimensional interactive virtual dissection model to simulate transpetrous surgical avenues. Neurosurgery 53: , 2003 (Letter) 6. Dandy WE: The brain, in Lewis D (ed): Practice of Surgery, Vol 12. Hagerstown, MD: WF Prior, 1932, pp Gorman PJ, Meier AH, Krummel TM: Simulation and virtual reality in surgical education: real or unreal? Arch Surg 134: , Gorman PJ, Meier AH, Rawn C, et al: The future of medical education is no longer blood and guts, it is bits and bytes. Am J Surg 180: , Henn JS, Lemole GM Jr, Ferreira MA, et al: Interactive stereoscopic virtual reality: a new tool for neurosurgical education. Technical note. J Neurosurg 96: , Hodge CP, Yamamoto YL, Feindel W: Fluorescein angiography of the brain the photographic procedure, J Biol Photogr 67:35 48, Hoffman H, Vu D: Virtual reality: teaching tool of the twenty-first century? Acad Med 72: , Kling-Petersen T, Pascher R, Rydmark M: 3D-brain 2.0 narrowing the gap between personal computers and high end workstations. Stud Health Technol Inform 50: , Kling-Petersen T, Pascher R, Rydmark M: Virtual reality on the web: the potentials of different methodologies and visualization techniques for scientific research and medical education. Stud Health Technol Inform 62: , Liu CY, Spicer M, Apuzzo ML: The genesis of neurosurgery and the evolution of the neurosurgical operative environment: Part II concepts for future development, 2003 and beyond. Neurosurgery 52:20 35, Melder PC, Mair EA: Endoscopic photography: digital or 35 mm? Arch Otolaryngol Head Neck Surg 129: , Nieder GL, Scott JN, Anderson MD: Using QuickTime virtual reality objects in computer-assisted instruction of gross anatomy: Yorick the VR skull. Clin Anat 13: , Rhoton AL Jr: The posterior cranial fossa: microsurgical anatomy and surgical approaches. Neurosurgery 47 (Suppl):S5 S6, Spicer MA, Apuzzo ML: Virtual reality surgery: neurosurgery and the contemporary landscape. Neurosurgery 52: , Wanzel KR, Hamstra SJ, Anastakis DJ, et al: Effect of visual-spatial ability on learning of spatially-complex surgical skills. Lancet 359: , 2002 (Letter) Manuscript received June 27, Accepted in final form December 15, Address reprint requests to: Robert F. Spetzler, M.D., c/o Neuroscience Publications, Barrow Neurological Institute, 350 West Thomas Road, Phoenix, Arizona neuropub@chw.edu. 596 J. Neurosurg. / Volume 100 / April, 2004

Interactive stereoscopic virtual reality: a new tool for neurosurgical education

Interactive stereoscopic virtual reality: a new tool for neurosurgical education Use your 3D glasses from the December 2001 issue to view images in this article. J Neurosurg 96:144 149, 2002 Interactive stereoscopic virtual reality: a new tool for neurosurgical education Technical

More information

Virtual and Augmented Reality techniques embedded and based on a Operative Microscope. Training for Neurosurgery.

Virtual and Augmented Reality techniques embedded and based on a Operative Microscope. Training for Neurosurgery. Virtual and Augmented Reality techniques embedded and based on a Operative Microscope. Training for Neurosurgery. 1 M. Aschke 1, M.Ciucci 1,J.Raczkowsky 1, R.Wirtz 2, H. Wörn 1 1 IPR, Institute for Process

More information

Computers in Biology and Medicine

Computers in Biology and Medicine Computers in Biology and Medicine 42 (2012) 692 696 Contents lists available at SciVerse ScienceDirect Computers in Biology and Medicine journal homepage: www.elsevier.com/locate/cbm Construction of a

More information

NeuroSim - The Prototype of a Neurosurgical Training Simulator

NeuroSim - The Prototype of a Neurosurgical Training Simulator NeuroSim - The Prototype of a Neurosurgical Training Simulator Florian BEIER a,1,stephandiederich a,kirstenschmieder b and Reinhard MÄNNER a,c a Institute for Computational Medicine, University of Heidelberg

More information

Using Web-Based Computer Graphics to Teach Surgery

Using Web-Based Computer Graphics to Teach Surgery Using Web-Based Computer Graphics to Teach Surgery Ken Brodlie Nuha El-Khalili Ying Li School of Computer Studies University of Leeds Position Paper for GVE99, Coimbra, Portugal Surgical Training Surgical

More information

CSC Stereography Course I. What is Stereoscopic Photography?... 3 A. Binocular Vision Depth perception due to stereopsis

CSC Stereography Course I. What is Stereoscopic Photography?... 3 A. Binocular Vision Depth perception due to stereopsis CSC Stereography Course 101... 3 I. What is Stereoscopic Photography?... 3 A. Binocular Vision... 3 1. Depth perception due to stereopsis... 3 2. Concept was understood hundreds of years ago... 3 3. Stereo

More information

INTRODUCING THE VIRTUAL REALITY FLIGHT SIMULATOR FOR SURGEONS

INTRODUCING THE VIRTUAL REALITY FLIGHT SIMULATOR FOR SURGEONS INTRODUCING THE VIRTUAL REALITY FLIGHT SIMULATOR FOR SURGEONS SAFE REPEATABLE MEASUREABLE SCALABLE PROVEN SCALABLE, LOW COST, VIRTUAL REALITY SURGICAL SIMULATION The benefits of surgical simulation are

More information

Stereoscopic Augmented Reality System for Computer Assisted Surgery

Stereoscopic Augmented Reality System for Computer Assisted Surgery Marc Liévin and Erwin Keeve Research center c a e s a r, Center of Advanced European Studies and Research, Surgical Simulation and Navigation Group, Friedensplatz 16, 53111 Bonn, Germany. A first architecture

More information

Novel machine interface for scaled telesurgery

Novel machine interface for scaled telesurgery Novel machine interface for scaled telesurgery S. Clanton, D. Wang, Y. Matsuoka, D. Shelton, G. Stetten SPIE Medical Imaging, vol. 5367, pp. 697-704. San Diego, Feb. 2004. A Novel Machine Interface for

More information

BodyViz fact sheet. BodyViz 2321 North Loop Drive, Suite 110 Ames, IA x555 www. bodyviz.com

BodyViz fact sheet. BodyViz 2321 North Loop Drive, Suite 110 Ames, IA x555 www. bodyviz.com BodyViz fact sheet BodyViz, the company, was established in 2007 at the Iowa State University Research Park in Ames, Iowa. It was created by ISU s Virtual Reality Applications Center Director James Oliver,

More information

Scopis Hybrid Navigation with Augmented Reality

Scopis Hybrid Navigation with Augmented Reality Scopis Hybrid Navigation with Augmented Reality Intelligent navigation systems for head surgery www.scopis.com Scopis Hybrid Navigation One System. Optical and electromagnetic measurement technology. As

More information

3D brain MR angiography displayed by a multi-autostereoscopic screen

3D brain MR angiography displayed by a multi-autostereoscopic screen 3D brain MR angiography displayed by a multi-autostereoscopic screen Magalhães, Daniel S. F. 1 ; Ribeiro, Fádua H. 1 ; Lima, Fabrício O. 1 ; Serra, Rolando L. 2 ; Moreno, Alfredo B. 2 ; Li, Li M. 1 1 Laboratório

More information

Basic Principles of the Surgical Microscope. by Charles L. Crain

Basic Principles of the Surgical Microscope. by Charles L. Crain Basic Principles of the Surgical Microscope by Charles L. Crain 2006 Charles L. Crain; All Rights Reserved Table of Contents 1. Basic Definition...3 2. Magnification...3 2.1. Illumination/Magnification...3

More information

Robots in the Field of Medicine

Robots in the Field of Medicine Robots in the Field of Medicine Austin Gillis and Peter Demirdjian Malden Catholic High School 1 Pioneers Robots in the Field of Medicine The use of robots in medicine is where it is today because of four

More information

The Holographic Human for surgical navigation using Microsoft HoloLens

The Holographic Human for surgical navigation using Microsoft HoloLens EPiC Series in Engineering Volume 1, 2018, Pages 26 30 ReVo 2017: Laval Virtual ReVolution 2017 Transhumanism++ Engineering The Holographic Human for surgical navigation using Microsoft HoloLens Tomoki

More information

CSE 190: Virtual Reality Technologies LECTURE #7: VR DISPLAYS

CSE 190: Virtual Reality Technologies LECTURE #7: VR DISPLAYS CSE 190: Virtual Reality Technologies LECTURE #7: VR DISPLAYS Announcements Homework project 2 Due tomorrow May 5 at 2pm To be demonstrated in VR lab B210 Even hour teams start at 2pm Odd hour teams start

More information

Robert B.Hallock Draft revised April 11, 2006 finalpaper2.doc

Robert B.Hallock Draft revised April 11, 2006 finalpaper2.doc How to Optimize the Sharpness of Your Photographic Prints: Part II - Practical Limits to Sharpness in Photography and a Useful Chart to Deteremine the Optimal f-stop. Robert B.Hallock hallock@physics.umass.edu

More information

CSC 170 Introduction to Computers and Their Applications. Lecture #3 Digital Graphics and Video Basics. Bitmap Basics

CSC 170 Introduction to Computers and Their Applications. Lecture #3 Digital Graphics and Video Basics. Bitmap Basics CSC 170 Introduction to Computers and Their Applications Lecture #3 Digital Graphics and Video Basics Bitmap Basics As digital devices gained the ability to display images, two types of computer graphics

More information

Learning Phacoemulsification Surgery In Virtual Reality Course ESCRS: Sept. 6, 2010,

Learning Phacoemulsification Surgery In Virtual Reality Course ESCRS: Sept. 6, 2010, Söderberg PG, Laurell C-G, Virtual reality ocular surgery 1(7) Learning Phacoemulsification Surgery In Virtual Reality Course ESCRS: Sept. 6, 2010, 17.00-18.00 17.00 Per G Söderberg Learning motor skills

More information

Application of 3D Terrain Representation System for Highway Landscape Design

Application of 3D Terrain Representation System for Highway Landscape Design Application of 3D Terrain Representation System for Highway Landscape Design Koji Makanae Miyagi University, Japan Nashwan Dawood Teesside University, UK Abstract In recent years, mixed or/and augmented

More information

Omni-Directional Catadioptric Acquisition System

Omni-Directional Catadioptric Acquisition System Technical Disclosure Commons Defensive Publications Series December 18, 2017 Omni-Directional Catadioptric Acquisition System Andreas Nowatzyk Andrew I. Russell Follow this and additional works at: http://www.tdcommons.org/dpubs_series

More information

Surgical robot simulation with BBZ console

Surgical robot simulation with BBZ console Review Article on Thoracic Surgery Surgical robot simulation with BBZ console Francesco Bovo 1, Giacomo De Rossi 2, Francesco Visentin 2,3 1 BBZ srl, Verona, Italy; 2 Department of Computer Science, Università

More information

Realistic Visual Environment for Immersive Projection Display System

Realistic Visual Environment for Immersive Projection Display System Realistic Visual Environment for Immersive Projection Display System Hasup Lee Center for Education and Research of Symbiotic, Safe and Secure System Design Keio University Yokohama, Japan hasups@sdm.keio.ac.jp

More information

Medical Robotics. Part II: SURGICAL ROBOTICS

Medical Robotics. Part II: SURGICAL ROBOTICS 5 Medical Robotics Part II: SURGICAL ROBOTICS In the last decade, surgery and robotics have reached a maturity that has allowed them to be safely assimilated to create a new kind of operating room. This

More information

The development of a virtual laboratory based on Unreal Engine 4

The development of a virtual laboratory based on Unreal Engine 4 The development of a virtual laboratory based on Unreal Engine 4 D A Sheverev 1 and I N Kozlova 1 1 Samara National Research University, Moskovskoye shosse 34А, Samara, Russia, 443086 Abstract. In our

More information

Multi-Access Biplane Lab

Multi-Access Biplane Lab Multi-Access Biplane Lab Advanced technolo gies deliver optimized biplane imaging Designed in concert with leading physicians, the Infinix VF-i/BP provides advanced, versatile patient access to meet the

More information

MacroPATH The new line of Digital Imaging Systems for Grossing

MacroPATH The new line of Digital Imaging Systems for Grossing MILESTONE H E L P I N G P A T I E N T S MacroPATH The new line of Digital Imaging Systems for Grossing If the dimensions of the specimen are not recorded, the key section not taken, and the proper special

More information

ience e Schoo School of Computer Science Bangor University

ience e Schoo School of Computer Science Bangor University ience e Schoo ol of Com mpute er Sc Visual Computing in Medicine The Bangor Perspective School of Computer Science Bangor University Pryn hwn da Croeso y RIVIC am Prifysgol Abertawe Siarad Cymraeg? Schoo

More information

VR for Microsurgery. Design Document. Team: May1702 Client: Dr. Ben-Shlomo Advisor: Dr. Keren Website:

VR for Microsurgery. Design Document. Team: May1702 Client: Dr. Ben-Shlomo Advisor: Dr. Keren   Website: VR for Microsurgery Design Document Team: May1702 Client: Dr. Ben-Shlomo Advisor: Dr. Keren Email: med-vr@iastate.edu Website: Team Members/Role: Maggie Hollander Leader Eric Edwards Communication Leader

More information

The TRC-NW8F Plus: As a multi-function retinal camera, the TRC- NW8F Plus captures color, red free, fluorescein

The TRC-NW8F Plus: As a multi-function retinal camera, the TRC- NW8F Plus captures color, red free, fluorescein The TRC-NW8F Plus: By Dr. Beth Carlock, OD Medical Writer Color Retinal Imaging, Fundus Auto-Fluorescence with exclusive Spaide* Filters and Optional Fluorescein Angiography in One Single Instrument W

More information

Chapter 1 Virtual World Fundamentals

Chapter 1 Virtual World Fundamentals Chapter 1 Virtual World Fundamentals 1.0 What Is A Virtual World? {Definition} Virtual: to exist in effect, though not in actual fact. You are probably familiar with arcade games such as pinball and target

More information

RENDERING MEDICAL INTERVENTIONS VIRTUAL AND ROBOT

RENDERING MEDICAL INTERVENTIONS VIRTUAL AND ROBOT RENDERING MEDICAL INTERVENTIONS VIRTUAL AND ROBOT Lavinia Ioana Săbăilă Doina Mortoiu Theoharis Babanatsas Aurel Vlaicu Arad University, e-mail: lavyy_99@yahoo.com Aurel Vlaicu Arad University, e mail:

More information

The Visible Ear Simulator Dissection Manual.

The Visible Ear Simulator Dissection Manual. The Visible Ear Simulator Dissection Manual. Stereoscopic Tutorialized Version 3.1, August 2017 Peter Trier Mikkelsen, the Alexandra Institute A/S, Aarhus, Denmark Mads Sølvsten Sørensen & Steven Andersen,

More information

Fracture fixation providing absolute or relative stability, as required by the personality of the fracture, the patient, and the injury.

Fracture fixation providing absolute or relative stability, as required by the personality of the fracture, the patient, and the injury. Course program AOCMF Advanced Innovations Symposium & Workshop on Technological Advances in Head and Neck and Craniofacial Surgery December 8-11, 2011, Bangalore, India Our mission is to continuously set

More information

VR-programming. Fish Tank VR. To drive enhanced virtual reality display setups like. Monitor-based systems Use i.e.

VR-programming. Fish Tank VR. To drive enhanced virtual reality display setups like. Monitor-based systems Use i.e. VR-programming To drive enhanced virtual reality display setups like responsive workbenches walls head-mounted displays boomes domes caves Fish Tank VR Monitor-based systems Use i.e. shutter glasses 3D

More information

ROTATING SYSTEM T-12, T-20, T-50, T- 150 USER MANUAL

ROTATING SYSTEM T-12, T-20, T-50, T- 150 USER MANUAL ROTATING SYSTEM T-12, T-20, T-50, T- 150 USER MANUAL v. 1.11 released 12.02.2016 Table of contents Introduction to the Rotating System device 3 Device components 4 Technical characteristics 4 Compatibility

More information

THE USE OF OPEN REDUCtion

THE USE OF OPEN REDUCtion ORIGINAL ARTICLE Comparison of 3 Optical Navigation Systems for Computer-Aided Maxillofacial Surgery E. Bradley Strong, MD; Amir Rafii, MD; Bettina Holhweg-Majert, MD, DMD; Scott C. Fuller, MD; Marc Christian

More information

Which equipment is necessary? How is the panorama created?

Which equipment is necessary? How is the panorama created? Congratulations! By purchasing your Panorama-VR-System you have acquired a tool, which enables you - together with a digital or analog camera, a tripod and a personal computer - to generate high quality

More information

Headline. SL 130 Slit Lamp. Subline. Maximum quality for optimum performance

Headline. SL 130 Slit Lamp. Subline. Maximum quality for optimum performance Headline SL 130 Slit Lamp Subline Maximum quality for optimum performance Versatility is the outstanding feature of the SL 130 slit lamp from Carl Zeiss. Combined with an advanced, user-focused operating

More information

Real World / Virtual Presentations: Comparing Different Web-based 4D Presentation Techniques of the Built Environment

Real World / Virtual Presentations: Comparing Different Web-based 4D Presentation Techniques of the Built Environment Real World / Virtual Presentations: Comparing Different Web-based 4D Presentation Techniques of the Built Environment Joseph BLALOCK 1 Introduction The World Wide Web has had a great effect on the display

More information

OPHTHALMIC SURGICAL MODELS

OPHTHALMIC SURGICAL MODELS OPHTHALMIC SURGICAL MODELS BIONIKO designs innovative surgical models, task trainers and teaching tools for the ophthalmic industry. Our surgical models present the user with dexterity and coordination

More information

Evaluation of usefulness of 3D views for clinical photography

Evaluation of usefulness of 3D views for clinical photography BioScience Trends. 2011; 5(5):211-216. 211 Original Article DOI: 10.5582/bst.2011.v5.5.211 Evaluation of usefulness of 3D views for clinical photography Masatoshi Jinnin*, Satoshi Fukushima, Shinichi Masuguchi,

More information

1. Kaidan s web site has a page showing tips and possible set-ups for mounting the object and camera.

1. Kaidan s web site has a page showing tips and possible set-ups for mounting the object and camera. 5. Additional Related Media 5.1. Object/inverse panoramas Panoramas show a scene from a single anchored point in space looking out in all directions. Virtual reality (VR) objects can be thought of as an

More information

PathStation TM Fits Your Lab

PathStation TM Fits Your Lab PathStation TM Fits Your Lab PathStation hood Compact In-hood Imaging system. Supports in-process documentation PathStation Key Features 20 MP Image Capture Great HD Video 8.33 X Optical zoom 4X Digital

More information

Robot assisted craniofacial surgery: first clinical evaluation

Robot assisted craniofacial surgery: first clinical evaluation Robot assisted craniofacial surgery: first clinical evaluation C. Burghart*, R. Krempien, T. Redlich+, A. Pernozzoli+, H. Grabowski*, J. Muenchenberg*, J. Albers#, S. Haßfeld+, C. Vahl#, U. Rembold*, H.

More information

Instruments Commonly Used For Examination of the Eye

Instruments Commonly Used For Examination of the Eye Instruments Commonly Used For Examination of the Eye There are many instruments that the eye doctor might use to evaluate the eye and the vision system. This report presents some of the more commonly used

More information

3D and Sequential Representations of Spatial Relationships among Photos

3D and Sequential Representations of Spatial Relationships among Photos 3D and Sequential Representations of Spatial Relationships among Photos Mahoro Anabuki Canon Development Americas, Inc. E15-349, 20 Ames Street Cambridge, MA 02139 USA mahoro@media.mit.edu Hiroshi Ishii

More information

MEDICAL & LIFE SCIENCES

MEDICAL & LIFE SCIENCES MEDICAL & LIFE SCIENCES Basler cameras - the power of sight for medical and life science technology Broad industrial camera portfolio for digital imaging -year warranty, long-term availability Trust in

More information

Evaluation of Operative Imaging Techniques in Surgical Education

Evaluation of Operative Imaging Techniques in Surgical Education SCIENTIFIC PAPER Evaluation of Operative Imaging Techniques in Surgical Education Shanu N. Kothari, MD, Timothy J. Broderick, MD, Eric J. DeMaria, MD, Ronald C. Merrell, MD ABSTRACT Background: Certain

More information

Learning and teaching medicine is a difficult task, partially. Virtual and stereoscopic anatomy: when virtual reality meets medical education

Learning and teaching medicine is a difficult task, partially. Virtual and stereoscopic anatomy: when virtual reality meets medical education laboratory investigation J Neurosurg 125:1105 1111, 2016 Virtual and stereoscopic anatomy: when virtual reality meets medical education Jose Weber Vieira de Faria, MD, PhD, 1 Manoel Jacobsen Teixeira,

More information

Film Cameras Digital SLR Cameras Point and Shoot Bridge Compact Mirror less

Film Cameras Digital SLR Cameras Point and Shoot Bridge Compact Mirror less Film Cameras Digital SLR Cameras Point and Shoot Bridge Compact Mirror less Portraits Landscapes Macro Sports Wildlife Architecture Fashion Live Music Travel Street Weddings Kids Food CAMERA SENSOR

More information

A reduction of visual fields during changes in the background image such as while driving a car and looking in the rearview mirror

A reduction of visual fields during changes in the background image such as while driving a car and looking in the rearview mirror Original Contribution Kitasato Med J 2012; 42: 138-142 A reduction of visual fields during changes in the background image such as while driving a car and looking in the rearview mirror Tomoya Handa Department

More information

Ayuekanbe Atagabe. Physics 464(applied Optics) Winter Project Report. Fiber Optics in Medicine. March 11, 2003

Ayuekanbe Atagabe. Physics 464(applied Optics) Winter Project Report. Fiber Optics in Medicine. March 11, 2003 Ayuekanbe Atagabe Physics 464(applied Optics) Winter 2003 Project Report Fiber Optics in Medicine March 11, 2003 Abstract: Fiber optics have become very important in medical diagnoses in this modern era

More information

Imagine your future lab. Designed using Virtual Reality and Computer Simulation

Imagine your future lab. Designed using Virtual Reality and Computer Simulation Imagine your future lab Designed using Virtual Reality and Computer Simulation Bio At Roche Healthcare Consulting our talented professionals are committed to optimising patient care. Our diverse range

More information

Development of SEM for Realtime 3D Imaging and Its Applications in Biology

Development of SEM for Realtime 3D Imaging and Its Applications in Biology 218 Hitachi Review Vol. 65 (2016), No. 7 Special Contributions Development of SEM for Realtime 3D Imaging and Its Applications in Biology Tatsuo Ushiki, M.D., Ph.D. Futoshi Iwata, Ph.D. Wataru Kotake Sukehiro

More information

Second Generation Haptic Ventriculostomy Simulator Using the ImmersiveTouch System

Second Generation Haptic Ventriculostomy Simulator Using the ImmersiveTouch System Second Generation Haptic Ventriculostomy Simulator Using the ImmersiveTouch System Cristian LUCIANO a1, Pat BANERJEE ab, G. Michael LEMOLE, Jr. c and Fady CHARBEL c a Department of Computer Science b Department

More information

Virtual and Augmented Reality Applications

Virtual and Augmented Reality Applications Department of Engineering for Innovation University of Salento Lecce, Italy Augmented and Virtual Reality Laboratory (AVR Lab) Keynote Speech: Augmented and Virtual Reality Laboratory (AVR Lab) Keynote

More information

Time-Lapse Panoramas for the Egyptian Heritage

Time-Lapse Panoramas for the Egyptian Heritage Time-Lapse Panoramas for the Egyptian Heritage Mohammad NABIL Anas SAID CULTNAT, Bibliotheca Alexandrina While laser scanning and Photogrammetry has become commonly-used methods for recording historical

More information

Haptic control in a virtual environment

Haptic control in a virtual environment Haptic control in a virtual environment Gerard de Ruig (0555781) Lourens Visscher (0554498) Lydia van Well (0566644) September 10, 2010 Introduction With modern technological advancements it is entirely

More information

RISKS AND BENEFITS OF VIRTUAL REALITY WITHIN A MULTI-SITE ORGANISATION

RISKS AND BENEFITS OF VIRTUAL REALITY WITHIN A MULTI-SITE ORGANISATION RISKS AND BENEFITS OF VIRTUAL REALITY WITHIN A MULTI-SITE ORGANISATION Ms Kelly Jaunzems Professor Lelia Green Dr David Leith Effective communication channels in occupational health and safety PhD research

More information

Immersive Training. David Lafferty President of Scientific Technical Services And ARC Associate

Immersive Training. David Lafferty President of Scientific Technical Services And ARC Associate Immersive Training David Lafferty President of Scientific Technical Services And ARC Associate Current Situation Great Shift Change Drive The Need For Training Conventional Training Methods Are Expensive

More information

Reprint (R37) DLP Products DMD-Based Hyperspectral Imager Makes Surgery Easier

Reprint (R37) DLP Products DMD-Based Hyperspectral Imager Makes Surgery Easier Reprint (R37) DLP Products DMD-Based Hyperspectral Imager Makes Surgery Easier Reprinted with permission by Dr. Karel J. Zuzak University of Texas/Arlington October 2008 Gooch & Housego 4632 36 th Street,

More information

Robert Mark and Evelyn Billo

Robert Mark and Evelyn Billo Mark and Billo A Stitch in Time: Digital Panoramas and Mosaics Robert Mark and Evelyn Billo Digital or digitized images, stitched together with sophisticated computer software, can be used to produce panoramas

More information

Open surgery SIMULATION

Open surgery SIMULATION Open surgery SIMULATION ossimtech.com A note from the President and Co-Founder, Mr. André Blain Medical education and surgical training are going through exciting changes these days. Fast-paced innovation

More information

Project Abstract Submission : Entry # 456. Part 1 - Team. Part 2 - Project. Team Leader Name. Maroua Filali. Team Leader .

Project Abstract Submission : Entry # 456. Part 1 - Team. Part 2 - Project. Team Leader Name. Maroua Filali. Team Leader  . Part 1 - Team Team Leader Name Maroua Filali Team Leader Email mf1304494@qu.edu.qa 2nd Team Member Name Ealaf Hussein 2nd Team Member Email eh1300622@qu.edu.qa 3rd Team Member Name Salma Shalaby 3rd Team

More information

VR based HCI Techniques & Application. November 29, 2002

VR based HCI Techniques & Application. November 29, 2002 VR based HCI Techniques & Application November 29, 2002 stefan.seipel@hci.uu.se What is Virtual Reality? Coates (1992): Virtual Reality is electronic simulations of environments experienced via head mounted

More information

USING BLUETOOTH TM TO MEASURE TRAVEL TIME ALONG ARTERIAL CORRIDORS

USING BLUETOOTH TM TO MEASURE TRAVEL TIME ALONG ARTERIAL CORRIDORS USING BLUETOOTH TM TO MEASURE TRAVEL TIME ALONG ARTERIAL CORRIDORS A Comparative Analysis Submitted To: City of Philadelphia Department of Streets Philadelphia, PA Prepared By: KMJ Consulting, Inc. 120

More information

A Virtual Reality Surgical Trainer for Navigation in Laparoscopic Surgery

A Virtual Reality Surgical Trainer for Navigation in Laparoscopic Surgery Medicine Meets Virtual Reality 2001 J.D. Westwood et al. (Eds) IOS Press, 2001 A Virtual Reality Surgical Trainer for Navigation in Laparoscopic Surgery Randy S. Haluck M.D. 1, Roger W. Webster Ph.D. 2,

More information

One Size Doesn't Fit All Aligning VR Environments to Workflows

One Size Doesn't Fit All Aligning VR Environments to Workflows One Size Doesn't Fit All Aligning VR Environments to Workflows PRESENTATION TITLE DATE GOES HERE By Show of Hands Who frequently uses a VR system? By Show of Hands Immersive System? Head Mounted Display?

More information

Why the Anatomage Table?

Why the Anatomage Table? Why the Anatomage Table? Compare Anatomage Table Cadaver Lab Chemicals No Formaldehyde, methanol, phenol, & other solvents Facility No special requirements Ventilation, freezer, storage, & disposal Restrictions

More information

Measurements of the Level of Surgical Expertise Using Flight Path Analysis from da Vinci Robotic Surgical System

Measurements of the Level of Surgical Expertise Using Flight Path Analysis from da Vinci Robotic Surgical System Measurements of the Level of Surgical Expertise Using Flight Path Analysis from da Vinci Robotic Surgical System Lawton Verner 1, Dmitry Oleynikov, MD 1, Stephen Holtmann 1, Hani Haider, Ph D 1, Leonid

More information

Nikon. King s College London. Imaging Centre. N-SIM guide NIKON IMAGING KING S COLLEGE LONDON

Nikon. King s College London. Imaging Centre. N-SIM guide NIKON IMAGING KING S COLLEGE LONDON N-SIM guide NIKON IMAGING CENTRE @ KING S COLLEGE LONDON Starting-up / Shut-down The NSIM hardware is calibrated after system warm-up occurs. It is recommended that you turn-on the system for at least

More information

Instructions for the Experiment

Instructions for the Experiment Instructions for the Experiment Excitonic States in Atomically Thin Semiconductors 1. Introduction Alongside with electrical measurements, optical measurements are an indispensable tool for the study of

More information

One Week to Better Photography

One Week to Better Photography One Week to Better Photography Glossary Adobe Bridge Useful application packaged with Adobe Photoshop that previews, organizes and renames digital image files and creates digital contact sheets Adobe Photoshop

More information

USER-ORIENTED INTERACTIVE BUILDING DESIGN *

USER-ORIENTED INTERACTIVE BUILDING DESIGN * USER-ORIENTED INTERACTIVE BUILDING DESIGN * S. Martinez, A. Salgado, C. Barcena, C. Balaguer RoboticsLab, University Carlos III of Madrid, Spain {scasa@ing.uc3m.es} J.M. Navarro, C. Bosch, A. Rubio Dragados,

More information

Design and Implementation of the 3D Real-Time Monitoring Video System for the Smart Phone

Design and Implementation of the 3D Real-Time Monitoring Video System for the Smart Phone ISSN (e): 2250 3005 Volume, 06 Issue, 11 November 2016 International Journal of Computational Engineering Research (IJCER) Design and Implementation of the 3D Real-Time Monitoring Video System for the

More information

Accuracy evaluation of an image overlay in an instrument guidance system for laparoscopic liver surgery

Accuracy evaluation of an image overlay in an instrument guidance system for laparoscopic liver surgery Accuracy evaluation of an image overlay in an instrument guidance system for laparoscopic liver surgery Matteo Fusaglia 1, Daphne Wallach 1, Matthias Peterhans 1, Guido Beldi 2, Stefan Weber 1 1 Artorg

More information

Augmented Reality to Localize Individual Organ in Surgical Procedure

Augmented Reality to Localize Individual Organ in Surgical Procedure Tutorial Healthc Inform Res. 2018 October;24(4):394-401. https://doi.org/10.4258/hir.2018.24.4.394 pissn 2093-3681 eissn 2093-369X Augmented Reality to Localize Individual Organ in Surgical Procedure Dongheon

More information

6Visionaut visualization technologies SIMPLE PROPOSAL 3D SCANNING

6Visionaut visualization technologies SIMPLE PROPOSAL 3D SCANNING 6Visionaut visualization technologies 3D SCANNING Visionaut visualization technologies7 3D VIRTUAL TOUR Navigate within our 3D models, it is an unique experience. They are not 360 panoramic tours. You

More information

www.anatomage.com info@anatomage.com Why The Anatomage Table? Advanced Educational Tool Both the accuracy of the real human anatomy and the quantity of pathological examples are unique aspects of the Anatomage

More information

Improving Depth Perception in Medical AR

Improving Depth Perception in Medical AR Improving Depth Perception in Medical AR A Virtual Vision Panel to the Inside of the Patient Christoph Bichlmeier 1, Tobias Sielhorst 1, Sandro M. Heining 2, Nassir Navab 1 1 Chair for Computer Aided Medical

More information

What s Fundus photography s purpose? Why do we take them? Why do we do it? Why do we do it? Why do we do it? 11/3/2014. To document the retina

What s Fundus photography s purpose? Why do we take them? Why do we do it? Why do we do it? Why do we do it? 11/3/2014. To document the retina What s Fundus photography s purpose? To document the retina Photographers role to show the retina Document other ocular structures Why do we take them? Why do we do it? We as photographers help the MD

More information

Virtual Reality Based Scalable Framework for Travel Planning and Training

Virtual Reality Based Scalable Framework for Travel Planning and Training Virtual Reality Based Scalable Framework for Travel Planning and Training Loren Abdulezer, Jason DaSilva Evolving Technologies Corporation, AXS Lab, Inc. la@evolvingtech.com, jdasilvax@gmail.com Abstract

More information

A New Paradigm for Head-Mounted Display Technology: Application to Medical Visualization and Remote Collaborative Environments

A New Paradigm for Head-Mounted Display Technology: Application to Medical Visualization and Remote Collaborative Environments Invited Paper A New Paradigm for Head-Mounted Display Technology: Application to Medical Visualization and Remote Collaborative Environments J.P. Rolland', Y. Ha', L. Davjs2'1, H. Hua3, C. Gao', and F.

More information

A Haptic-enabled Toolkit for Illustration of Procedures in Surgery (TIPS)

A Haptic-enabled Toolkit for Illustration of Procedures in Surgery (TIPS) A Haptic-enabled Toolkit for Illustration of Procedures in Surgery (TIPS) Minho KIM a;1, Tianyun NI a, Juan CENDAN b, Sergei KURENOV b, and Jörg PETERS a a Dept. CISE, University of Florida b Dept. Surgery,

More information

How to combine images in Photoshop

How to combine images in Photoshop How to combine images in Photoshop In Photoshop, you can use multiple layers to combine images, but there are two other ways to create a single image from mulitple images. Create a panoramic image with

More information

25 Questions. All are multiple choice questions. 4 will require an additional written response explaining your answer.

25 Questions. All are multiple choice questions. 4 will require an additional written response explaining your answer. 9 th Grade Digital Photography Final Review- Written Portion of Exam EXAM STRUCTURE: 25 Questions. All are multiple choice questions. 4 will require an additional written response explaining your answer.

More information

Current Status and Future of Medical Virtual Reality

Current Status and Future of Medical Virtual Reality 2011.08.16 Medical VR Current Status and Future of Medical Virtual Reality Naoto KUME, Ph.D. Assistant Professor of Kyoto University Hospital 1. History of Medical Virtual Reality Virtual reality (VR)

More information

Panoramas. Featuring ROD PLANCK. Rod Planck DECEMBER 29, 2017 ADVANCED

Panoramas. Featuring ROD PLANCK. Rod Planck DECEMBER 29, 2017 ADVANCED DECEMBER 29, 2017 ADVANCED Panoramas Featuring ROD PLANCK Rod Planck D700, PC-E Micro NIKKOR 85mm f/2.8d, 1/8 second, f/16, ISO 200, manual exposure, Matrix metering. When we asked the noted outdoor and

More information

HD aerial video for coastal zone ecological mapping

HD aerial video for coastal zone ecological mapping HD aerial video for coastal zone ecological mapping Albert K. Chong University of Otago, Dunedin, New Zealand Phone: +64 3 479-7587 Fax: +64 3 479-7586 Email: albert.chong@surveying.otago.ac.nz Presented

More information

MODULE No. 34: Digital Photography and Enhancement

MODULE No. 34: Digital Photography and Enhancement SUBJECT Paper No. and Title Module No. and Title Module Tag PAPER No. 8: Questioned Document FSC_P8_M34 TABLE OF CONTENTS 1. Learning Outcomes 2. Introduction 3. Cameras and Scanners 4. Image Enhancement

More information

OCULAR MEDIA* PHOTOGRAPHIC RECORDING OF OPACITIES OF THE. development by the control of diabetes, the supply of a deficient hormone

OCULAR MEDIA* PHOTOGRAPHIC RECORDING OF OPACITIES OF THE. development by the control of diabetes, the supply of a deficient hormone Brit. J. Ophthal. (1955) 39, 85. PHOTOGRAPHIC RECORDING OF OPACITIES OF THE OCULAR MEDIA* BY E. F. FINCHAM Institute of Ophthalmology, University of London THE value of photography for recording pathological

More information

University of Geneva. Presentation of the CISA-CIN-BBL v. 2.3

University of Geneva. Presentation of the CISA-CIN-BBL v. 2.3 University of Geneva Presentation of the CISA-CIN-BBL 17.05.2018 v. 2.3 1 Evolution table Revision Date Subject 0.1 06.02.2013 Document creation. 1.0 08.02.2013 Contents added 1.5 12.02.2013 Some parts

More information

SMart wearable Robotic Teleoperated surgery

SMart wearable Robotic Teleoperated surgery SMart wearable Robotic Teleoperated surgery This project has received funding from the European Union s Horizon 2020 research and innovation programme under grant agreement No 732515 Context Minimally

More information

Augmented Navigation Patricia Sazama, Xuetong Sun, Derek Juba, and Amitabh Varshney

Augmented Navigation Patricia Sazama, Xuetong Sun, Derek Juba, and Amitabh Varshney Patricia Sazama, Xuetong Sun, Derek Juba, and Amitabh Varshney Two Domains Augmented Driving (and walking) Augmented Surgery Augmented Driving Problem Augment what we can see while driving with additional

More information

SIMULATION MODELING WITH ARTIFICIAL REALITY TECHNOLOGY (SMART): AN INTEGRATION OF VIRTUAL REALITY AND SIMULATION MODELING

SIMULATION MODELING WITH ARTIFICIAL REALITY TECHNOLOGY (SMART): AN INTEGRATION OF VIRTUAL REALITY AND SIMULATION MODELING Proceedings of the 1998 Winter Simulation Conference D.J. Medeiros, E.F. Watson, J.S. Carson and M.S. Manivannan, eds. SIMULATION MODELING WITH ARTIFICIAL REALITY TECHNOLOGY (SMART): AN INTEGRATION OF

More information

Holographic Stereograms and their Potential in Engineering. Education in a Disadvantaged Environment.

Holographic Stereograms and their Potential in Engineering. Education in a Disadvantaged Environment. Holographic Stereograms and their Potential in Engineering Education in a Disadvantaged Environment. B. I. Reed, J Gryzagoridis, Department of Mechanical Engineering, University of Cape Town, Private Bag,

More information

United States Patent (19) Mihalca et al.

United States Patent (19) Mihalca et al. United States Patent (19) Mihalca et al. 54) STEREOSCOPIC IMAGING BY ALTERNATELY BLOCKING LIGHT 75 Inventors: Gheorghe Mihalca, Chelmsford; Yuri E. Kazakevich, Andover, both of Mass. 73 Assignee: Smith

More information

Truly flexible to meet your clinical needs

Truly flexible to meet your clinical needs Truly flexible to meet your clinical needs 2 Adapting to meet your needs Flexible Fast and responsive Excellent image quality Designed with ergonomic efficiency Equipped with dose management tools 3 Three

More information

The Anatomical Study of Superior and Middle Turbinates from Endoscopic Perspective

The Anatomical Study of Superior and Middle Turbinates from Endoscopic Perspective Original Research Article The Anatomical Study of Superior and Middle Turbinates from Endoscopic Perspective Gayatri Girish Muthiyan 1,*, Shanta Sunil Hattangdi 2, Payal Arvind Kasant 3 1 Assistant Professor,

More information