1 Incandescent Lighting: Enclosed and Gasketed 2-1 Page Description 2-11 Stylmaster Enclosed and Gasketed Incandescent ixtures 2, 3 eatures 4 Technical Data 5,6 ixture Assemblies 7 Mounting Hoods and Cast Outlet Boxes 8 Globes and Guards 9 Reflectors and Weights 10 Dimensions 11 Photometric Data V-51 Enclosed and Gasketed Incandescent ixtures 12,13 eatures Mounting Bodies, Hoods and ixture Units 20 Reflectors, Globes and Guards; Replacement Parts 21 Dimensions 22 Photometric Data PVI Enclosed Non-Metallic Incandescent ixtures 23 eatures 24 Replacement Parts and Dimensions 25 REA Enclosed and Gasketed Incandescent ixtures 25 eatures 25 Parts and Accessories 25 Dimensions Stylmaster Strobe and Beacon 26 eatures 27 Ordering Information and Technical Data 28 ixture Units 29 Replacement Parts and Dimensions N2LS Series 30 eatures Ordering Information 33 Technical Data 34 Dimensions 35 Photometric Data PAGE 1

2 2-2 Stylmaster Enclosed and Gasketed Incandescent Attractively styled fixture with prismatic globe. UNILETS for use with threaded metal conduit. Applications Enclosed and gasketed lighting fixtures for use in storage areas, tunnels, subways, chemical plants and other areas where moisture, dirt or corrosive atmospheres are a problem. Suitable for use in wet locations. Standard fixtures designed for 60- to 300-watt medium base incandescent lamps. Pendant, feed-thru, ceiling, stanchion and wall mounts available. Ventilated steel reflectors with white porcelain finish are available for standard applications. iberglassreinforced polyester reflectors are designed for installations where fixture is subject to severe corrosive conditions or vandalism. eatures Modern styling, with clean-line mounting hood and prismatic glass globe, plus optional guard. Prismatic globe, furnished as standard, eliminates glare and distributes light evenly. See Options for other globes available. Globe seats firmly against composition gasket in mounting hood to keep out dirt and moisture. ull threads eliminate cross threading. ixture is complete with gaskets and socket. Socket is shock-absorbing to prolong lamp life and can be easily removed for wiring without tools. Porcelain socket construction assures long trouble-free operation in high ambient installations. Both porcelain steel and polyester reflectors are secured to mounting hoods with screws (furnished). Guards have exclusive snap-on attachment feature for quick installation and fast servicing. Choice of reflector styles: (1) steel reflector with white porcelain enamel in standard dome and 30º angle; and (2) fiberglass-reinforced polyester reflector in standard dome and 30º angle. Standard Materials Mounting hoods: copper-free aluminum. Guards: pressure-cast copper-free aluminum. Reflectors: porcelain steel or fiberglass-reinforced polyester. Socket: porcelain with brass screw shell. Globes: prismatic glass. See Operations for other types available. Standard inishes Mounting hoods: epoxy powder coat. Aluminum guards: epoxy powder coat. Steel reflectors: baked white porcelain enamel. iberglass reinforced polyester reflectors: natural finish. Socket and globes: natural finish. PAGE 2

3 Stylmaster Enclosed and Gasketed Incandescent Attractively styled fixture with prismatic globe. UNILETS for use with threaded metal conduit. 2-3 Options To order fixture with other than standard clear glass globe, add suffix letters to catalog number as indicated in table, and adjust difference in price. Glass Plastic Color Globe Globe Mounting Hood Pendant style shown has setscrew to prevent fixture stem from turning. Other styles include stanchion, ceiling and wall mounting. Amber -AM -PAM Blue -BL -PBL Green -GR -PGR Red -RE -PRE Clear Heat-Resistant -HR Compliances UL Standard 1598 UL Standard 844 for Class I, Div. 2 fixtures Reference Data or additional data on lamp and lighting fixture selection, see general introduction to catalog. or Stylmaster fixtures designed for use with HID lamps, see catalog section 1. Shock-Absorbing Medium Base Socket Spring absorbs vibration to prolong lamp life. Porcelain construction for trouble-free operation in high ambient installations. Globe Attractive, tapered prismatic glass globes for glare elimination and uniform light distribution. Colors available also vandalresistant plastic globes. Globe seats firmly against gasket to exclude moisture, dirt and vapors. Guard Snap-on guards (and reflectors) simply snap-in and twist. Spring action balls snap into detents of fixture body. PAGE 3

4 2-4 Stylmaster Technical Data: Thermal Suitability of Stylmaster and V-51 ixtures Class I, Div. 2, Groups A, B, C and D. ixture is suitable for Class I, Div. 2 where the fixture operating temperature does not exceed the ignition temperature of the atmosphere in which fixture is installed. T Numbers Represent the Maximum Lamp Temperature for Class I, Div. 2 Locations T Number T T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6 Temp. Range (ºC) Supply Wire: Stylmaster 200 ºC; and V ºC Stylmaster VPGL-1HR (60-200W) VPGL-2HR ( W) Reflector A W A W A W A W PS W PS W PS W PS W None T3 T2D T2C T2C T2C T2C Standard Dome T2D T2D T2B T2B T2B T2C º Angle T2D T2C T2B T2B T2B T2B V W W Reflector A W PS W PS W PS W None T3 T2D T2C 325 Standard Dome T2D T2C T2B º Angle T2C T2C T2B 325 ixture Ambient Suitability Non-Classified Areas Stylmaster: 200 ºC (392 º); V-51: 75 ºC (167 º) Classified Areas Stylmaster: 40 ºC; V-51: 40 ºC (104 º) PAGE 4

5 Class I, Div. 2 Groups A,B,C,D UL 1598 UL 844 Stylmaster Enclosed and Gasketed Incandescent Suitable for use in wet locations. With Aluminum Mounting Hood and Prismatic Glass Globe. 2-5 Catalog Number Description (Size in Inches) With Globe and Guard With Globe Only Pendant 3/4 tapped opening. urnished with 3/4 to 1/2 reducer W A-23 1/2 or 3/4 VPA1075G VPA W PS-30 1/2 or 3/4 VPA2075G VPA2075 eed-thru With one close-up plug W A-23 1/2 VPC1050G VPC1050 3/4 VPC1075G VPC W PS-30 1/2 VPC2050G VPC2050 3/4 VPC2075G VPC2075 Ceiling ive Tapped Openings With mounting lugs and four close-up plugs W A-23 1/2 VPX1050G VPX1050 3/4 VPX1075G VPX W PS-30 1/2 VPX2050G VPX2050 3/4 VPX2075G VPX2075 Order reflectors and accessories separately. See pages 2-7, 2-8 and 2-9. PAGE 5

6 2-6 Class I, Div. 2 Groups A,B,C,D UL 1598 UL 844 Stylmaster Enclosed and Gasketed Incandescent Suitable for use in wet locations. With Aluminum Mounting Hood and Prismatic Glass Globe. Catalog Number Description (Size in Inches) With Globe and Guard With Globe Only 45 Stanchion 1-1/4 Conduit W A /4 VPAN10125G VPAN W PS /4 VPAN20125G VPAN20125 Wall Body includes outlet box with five tapped openings With mounting lugs and four close-up plugs W A-23 1/2 VPWB1050G VPWB1050 3/4 VPWB1075G VPWB W PS-30 1/2 VPWB2050G VPWB2050 3/4 VPWB2075G VPWB2075 Ceiling Outlet Box Mounting (Octagonal outlet boxes for non-classified areas only.) its SEH or VPJB cast outlet box, or 4 octagonal outlet box. urnished with screws and gasket W A-23 VPOB10G VPOB W PS-30 VPOB20G VPOB20 Wall Outlet Box Mounting (Octagonal outlet boxes for non-classified area only.) its SEH or VPJB cast outlet box, or 4 octagonal outlet box. urnished with screws and gasket W A-23 VPOBW10G VPOBW W PS-30 VPOBW20G VPOBW20 Order reflectors and accessories separately. See pages 2-7, 2-8 and 2-9. Order SEH box from catalog section A, 4 octagonal steel boxes from section OB and VPJB cast box from this catalog section. PAGE 6

7 Stylmaster Mounting Hoods and Cast Outlet Boxes Suitable for use in wet locations. Aluminum Mounting Hoods and Outlet Boxes. 2-7 Description (Size in Inches) Catalog Number Copper-ree Aluminum Pendant urnished with setscrew, 3/4 to 1/2 reducer for 1/2 stem, medium base socket. VPA75 eed-thru One close-up plug 1/2 VPC50 3/4 VPC75 Ceiling ive Tapped Openings our close-up plugs 1/2 VPX50 3/4 VPX75 45º Stanchion 1-1/4 VPAN125 Wall ive Tapped Openings in Outlet Box* our close-up plugs 1/2 VPWB50 3/4 VPWB75 Cast Outlet Box Only ive Tapped Openings our close-up plugs. No socket. its VPOB, VPOBW and VPWB. 1/2 VPJB50 3/4 VPJB75 Ceiling or Outlet Box (Octagonal outlet boxes for non-classified areas only) its SEH or VPJB cast outlet box, or 4 octagonal outlet box. With screws and gasket. Wall or Outlet Box* (Octagonal outlet boxes for non-classified areas only) its SEH or VPJB cast outlet box, or 4 octagonal outlet box. With screws and gasket. VPOB1 VPOBW1 * Use 30º angle reflectors for wall installations center line of fixture must be located at least 5-3/4 away from wall. Has four 3/16 dia. mounting holes located 90º apart on a 3-1/2 dia. center. PAGE 7

8 2-8 Stylmaster Globes, Guards and Parts Suitable for use in wet locations. Prismatic Glass Globes, Polycarbonate Globes and Aluminum Guards. Catalog Number Glass Globe VPGL-1HR Glass Globe VPGL-2HR Coated Glass Globe VPGL-2HRT Polycarbonate Globe VPGL-2PL Description Color Glass Polycarbonate* Glass and Polycarbonate* Globes W A-23 Clear VPGL-2PL Clear Heat-Resistant VPGL-1HR Amber VPGL-1AM VPGL-2AMPL Blue VPGL-1BL VPGL-2BLPL Green VPGL-1GR VPGL-2GRPL Red VPGL-1RE VPGL-2REPL Glass Globes W PS-30 Clear Clear Heat-Resistant VPGL-2HR Amber VPGL-2AM Blue VPGL-2BL Green VPGL-2GR Red VPGL-2RE Coated Tuff-Skin Glass Globes Contains globe safely even if glass is broken Heat-Resistant VPGL-2HRT Copper-ree Aluminum Guards W A-23 VPGU W PS-30 VPGU-2 Guard VPGU-1 Guard VPGU-2 Replacement Porcelain Shock-Absorbing Sockets W A-23 Medium Base and W PS-30 Medium Base VPLR-123 Medium Base VPLR-123 Globe Gasket VPGL-GK Replacement Gasket for Globes Neoprene for all Stylmaster globes VPGL-GK * Shatter-resistant for use in food processing plants, canneries, dairies, breweries, bakeries or anywhere broken glass would prove a hazard. Ideally suited for areas where vandalism, high replacement and high maintenance costs are a problem. CAUTION: Use maximum 200 W lamp less reflector, 100 W max. with reflector or colored globe. Do not use in ambients exceeding 25 ºC. or burning in vertical base-up position only. Registered trademark of Thomas Manufacturing Corporation, Parkton, Md. PAGE 8

9 Stylmaster Porcelain and Polyester Reflectors, and ixture Weights 2-9 Catalog Number Description Porcelain Steel Polyester Standard Dome Reflector LPR-25ST LPRP-25ST 30º Angle Reflector LPR-25AN LPRP-25AN ixture and Accessory Weights of Stylmaster and V-51. Typical Mounting Hoods ixture Pendant Lbs. eed-thru Lbs. Ceiling Lbs. Wall Lbs. Stanchion Lbs. Stylmaster VPA75 2 VPC75 2 VPX75 2 VPOBW10 3 VPAN V-51 VA75 2 VC75 3 VXHA75 4 VGA75 4 VMAN Globes and Guards Reflectors ixture Type Globe Lbs. Guard Lbs. Standard Dome Lbs. 30º Angle Lbs. Stylmaster W VPGL-1 2 VPGU-1 1 LPR-25ST 3 LPR-25AN W VPGL-2 3 VPGU-2 1 LPRP-25ST 2 LPRP-25AN 2 V W VGL-1CL 1 VGU-1* 1 VRW-1ST 3 VRW-1AN W VGL-2CL 2 VGU-2* 1 VRW-2ST 3 VRW-2AN 3 or weights in kilograms, multiply number of lbs. by * VWG-1 and VWG-2 Steel Guards weigh 1 lb. PAGE 9

10 2-10 Stylmaster Dimensions Pendant Mount 45 Stanchion Mount eed-thru Mount Ceiling Outlet Box Mount Ceiling Mount with Junction Box Junction Box Mounting Body Wall Mount with Junction Box Wall Outlet Box Mount * Height of hood is measured to bottom of flange. Height of globe and guard is from bottom of flange. Dimensions of angle are from center of pipe. Height is measured from pipe stop in stanchion hood. PAGE 10

11 Photometric data shown on this page is based on a 200-watt A-23 lamp and is representative of the performance for all Stylmaster incandescent fixtures. or candlepower values of fixtures with other lamps, multiply the given candlepower values by the following multipliers: for 75 W A ; for 100 W A ; for 150 W A ; and for 300 W PS or candlepower values of fixtures with guard, multiply by Stylmaster Photometric Data 2-11 Without Reflector Effective loor Cavity Reflectance (Rfc) is 20% % Ceiling Rcc % Walls Rw ROOM CAVITY RATIOS Standard Dome Effective loor Cavity Reflectance (Rfc) is 20% % Ceiling Rcc % Walls Rw ROOM CAVITY RATIOS Angle PAGE 11

12 2-12 V-51 Enclosed and Gasketed Incandescent UNILETS for use with threaded metal conduit. Applications Enclosed and gasketed lighting fixtures for use in storage areas, tunnels, subways, chemical plants and other areas where moisture, dirt or corrosive atmospheres are a problem. Suitable for use in wet locations. Standard fixtures designed for 60- to 300-watt medium base incandescent lamps. Available in pendant, 45º stanchion, and a variety of ceiling and wall mountings. eatures urnished with connection block for easy wiring. Unitized construction reduces installation and maintenance costs. Shock-absorbing porcelain socket for longer lamp life. Neoprene rubber ring in neck of reflector snaps into groove of mounting hood protects against vibration and chipping. Guard snaps into two recesses of adapter no clamps or setscrews. Available in three standard fixtures: (1) V-51 malleable iron mounting hood with aluminum adapter and guard; (2) all malleable iron (steel guard); and (3) all aluminum. Standard Materials Standard V-51 fixtures: malleable iron mounting hood with copperfree aluminum adapter and guard. Standard all malleable fixtures: malleable iron mounting hood and adapter with steel guard. Standard all aluminum fixtures: copper-free aluminum mounting hood, adapter and guard. Mounting hoods: malleable iron or copper-free aluminum. Globe adapters: malleable iron or pressure-cast copper-free aluminum. Socket: porcelain with brass screw shell. Globes: glass. Optional globes in polycarbonate plastic. Guards: steel or pressure-cast copper-free aluminum. Reflectors: porcelain enamel steel. PAGE 12 Standard inishes Standard V-51 fixtures: mounting hood, triple coat (1) zinc electroplate, (2) dichromate, and (3) epoxy powder coat. Adapter and guard, epoxy powder coat. Standard all malleable fixtures: mounting hood and adapter, triple coat (1) zinc electroplate, (2) dichromate, and (3) epoxy powder coat. Steel guard, zinc electroplate. Standard all aluminum fixtures: epoxy powder coat. Malleable mounting hoods: triplecoat (1) zinc electroplate, (2) dichromate, and (3) epoxy powder coat. Malleable globe adapters: triple coat (1) zinc electroplate, (2) dichromate, and (3) epoxy powder coat. Steel guard: zinc electroplate. Aluminum mounting hoods: epoxy powder coat. Aluminum globe adapters: epoxy powder coat. Aluminum guard: epoxy powder coat. Steel reflectors: white porcelain enamel. Socket and globes: natural finish.

13 V-51 Enclosed and Gasketed Incandescent UNILETS for use with threaded metal conduit Options To order fixture with other than standard clear glass globe, add suffix letters to catalog number as indicated in table below, and adjust difference in price. Cut-Away View Connection block is easily removed (loosen two screws) to permit quick wiring. Glass Globe Plastic Globe Color Suffix Suffix Amber -AM -PAM Blue -BL -PBL Green -GR -PGR Opal -OP Red -RE -PRE Clear (Heat-Resistant) -HR Compliances UL Standard UL Standard 844 for Class I, Div. 2 fixtures. Appleton malleable iron products conform to ASTM A47-77, Grade 32510, which has the following properties: tensile strength, 50,000 psi; yield, 32,000 psi; and elongation, 10%. Appleton aluminum products are produced from a high strength copper-free (4/10 of 1% max.) alloy. Mounting Hood Available in pendant (shown), ceiling, wall and 45º stanchion. Pendant has setscrew to prevent fixture from turning on stem. Neoprene Ring Neoprene attachment ring secures reflector to mounting hood no tools needed. Globe Adapter When adapter is threaded onto mounting hood, the socket makes electrical contact with connection block in mounting hood. Available in malleable iron (VAD-1M and VAD-2M) or aluminum (VAD-1 and VAD-2). Porcelain Enamel Reflectors Standard and 30º Angle. Guard Two sealed ball plunger units snap quickly, easily and securely into cavities of globe adapter. Guard can be used with or without a reflector. PAGE 13

14 2-14 Class I, Div. 2 Groups A,B,C,D UL 1598 UL 844 V-51 Enclosed and Gasketed Incandescent All fixtures suitable for use in wet locations. Catalog Number V-51 All Malleable Description (Size in Inches) V-51 with Guard* All Malleable with Guard* All Aluminum with Guard* Pendant W A21 1/2 VA1050G VA1050G-M VA1050G-A 3/4 VA1075G VA1075G-M VA1075G-A 1 VA1100G VA1100G-M 1-1/4 VA1125G VA1125G-M W PS30 1/2 VA2050G VA2050G-M VA2050G-A 3/4 VA2075G VA2075G-M VA2075G-A 1 VA2100G VA2100G-M 1-1/4 VA2125G VA2125G-M Ceiling ive Tapped Openings our close-up plugs W A21 1/2 VXHA1050G VXHA1050G-M VXHA1050G-A 3/4 VXHA1075G VXHA1075G-M VXHA1075G-A 1 VXHA1100G VXHA1100G-M VXHA10100G-A W PS30 1/2 VXHA2050G VXHA2050G-M VXHA2050G-A 3/4 VXHA2075G VXHA2075G-M VXHA2075G-A 1 VXHA2100G VXHA2100G-M VXHA20100G-A Wall JB Box Mounting its JB cast outlet box. Order box from catalog section A. Screws and gasket furnished with fixture W A21 JBW10G JBW10G-M JBW10G-A W PS30 JBW20G JBW20G-M JBW20G-A Ceiling JB Box Mounting its JB cast outlet box. Order box from catalog section A. Screws and gasket furnished with fixture W A21 JB10G JB10G-M JB10G-A W PS30 JB20G JB20G-M JB20G-A * See page 2-4 for temperature limits on individual V-51 fixtures. To order fixtures without guards, omit G suffix from catalog number. Order reflectors and accessories separately (page 2-20). **With heat-resistant glass globes or plastic globes. 30º angle reflector adaptable for 100 W fixture only, when mounted at least 4-1/2 from wall. PAGE 14

15 V-51 Enclosed and Gasketed Incandescent All fixtures suitable for use in wet locations.** 2-15 Catalog Number Description (Size in Inches) V-51 with Guard* All Aluminum with Guard* eed-thru W A21 1/2 VC1050G VC1050G-A 3/4 VC1075G VC1075G-A W PS30 1/2 VC2050G VC2050G-A 3/4 VC2075G VC2075G-A Ceiling Three Hubs W A21 1/2 VT1050G 3/4 VT1075G W PS30 1/2 VT2050G 3/4 VT2075G Outlet Box Mounting or SEH cast outlet box (section A) or 3-1/4 or 4 octagonal outlet box (section OB). Gasket and adapter plate furnished with fixture W A21 OBV10G OBV10G-A W PS30 OBV20G OBV20G-A Ceiling our Hubs W A21 1/2 VX1050G 3/4 VX1075G W PS30 1/2 VX2050G 3/4 VX2075G Ceiling Single Hub W A21 1/2 V1050G V1050G-A 3/4 V1075G V1075G-A W PS30 1/2 V2050G V2050G-A 3/4 V2075G V2075G-A * See page 2-4 for temperature limits on individual V-51 fixtures. To order fixtures without guards, omit G suffix from catalog number. Order reflectors and accessories separately (page 2-20). **With heat-resistant glass globes or plastic globes. PAGE 15

16 2-16 Class I, Div. 2 Groups A,B,C,D UL 1598 UL 844 V-51 Enclosed and Gasketed Incandescent All fixtures suitable for use in wet locations.** Catalog Number Description (Size in Inches) V-51 with Guard* All Aluminum with Guard* Wall One Tapped Hub in lange W A21 1/2 VGA1050G 3/4 VGA1075G W PS30 1/2 VGA2050G 3/4 VGA2075G Wall Vertical eed-thru W A21 1/2 VD1050G 3/4 VD1075G W PS30 1/2 VD2050G 3/4 VD2075G Wall Three Hubs Plus One Tapped Opening in Center of lange W A21 1/2 VGAT1050G 3/4 VGAT1075G VGAT1075G-A W PS30 1/2 VGAT2050G 3/4 VGAT2075G VGAT2075G-A 45 Stanchion Reflector not available for this fixture W A21 1-1/4 VMAN10125G-A W PS30 1-1/4 VMAN20125G-A * See page 2-4 for temperature limits on individual V-51 fixtures. To order fixtures without guards, omit G suffix from catalog number. Order reflectors and accessories separately (page 2-20). **With heat-resistant glass globes or plastic globes. 30º angle reflector adaptable for 100 W fixture only, when mounted at least 4-1/2 from wall. PAGE 16

17 Class I, Div. 2 Groups A,B,C,D UL 1598 UL 844 V-51 Enclosed and Gasketed Incandescent All fixtures suitable for use in wet locations.** 2-17 Catalog Number Description V-51 with Guard* All Aluminum with Guard* Wall Outlet Box Mounting (Octagonal outlet boxes for non-classified areas only) its SEH cast outlet box (catalog section A), VPJB (this section) or 3-1/4 or 4 octagonal outlet box (section OB). Gasket and adapter plate furnished with fixture W A-21 OBVW10G OBVW10G-A W PS-30 OBVW20G OBVW20G-A Ceiling GS orm 20 Box Mounting its GS cast outlet box. Order box from catalog section A. Screws and gasket furnished with fixture W A-21 GS102G W PS-30 GS202G Wall GS Box Mounting its GSU cast outlet box. Order box from catalog section A. Screws and gasket furnished with fixture W A-21 GSW102G W PS-30 GSW202G JB SEH or JB, GS and SEH Cast Outlet Boxes, see catalog section A. GS * See page 2-4 for temperature limits on individual V-51 fixtures. To order fixtures without guards, omit G suffix from catalog number. Order reflectors and accessories separately (Page 2-20). **With heat-resistant glass globes or plastic globes. 30º angle reflector adaptable for 100 W fixture only, when mounted at least 4-1/2 from wall. PAGE 17

18 2-18 V-51 Mounting Hoods: Pendant, Ceiling, Wall and Stanchion Suitable for use in wet locations. Malleable Iron or Aluminum Mounting Bodies. Hub Size Catalog Number Description (Inches) Malleable Iron Aluminum Pendant and Ceiling Mounting Hoods urnished with connection block, gasket and screws. Pendant Mounting 1/2 VA50 VA50-A 3/4 VA75 VA75-A 1 VA /4 VA125 Dead-End Ceiling Mounting 1/2 V50 V50-A 3/4 V75 V75-A eed-thru Ceiling Mounting 1/2 VC50 VC50-A 3/4 VC75 VC75-A Three Hubs Ceiling Mounting 1/2 VT50 3/4 VT75 our Hubs Ceiling Mounting 1/2 VX50 3/4 VX75 ive Hubs Ceiling Mounting 1/2 VXHA50 VXHA50-A 3/4 VXHA75 VXHA75-A 1 VXHA100 VXHA100-A Wall and Stanchion Mounting Hoods urnished with connection block, gasket and screws. One Opening Wall Mounting* 1 tapped hole in center of flange 1/2 VGA50 3/4 VGA75 eed-thru Wall Mounting* 2 tapped vertical feed-thru hubs 1/2 VD50 3/4 VD75 Three Hubs and One Opening Wall Mounting* 3 hubs plus 1 tapped opening in center of flange 1/2 VGAT50 3/4 VGAT75 VGAT75-A 45 Stanchion Mounting 1-1/4 VMAN-125 our close-up plugs furnished. * Mounting hoods for wall installations can only be used with 30º angle reflectors. PAGE 18

19 V-51 Mounting Hoods and Adapter ixture Units Suitable for use in wet locations. Malleable Iron or Aluminum Components Catalog Number Description Malleable Iron Aluminum Wall and Ceiling Outlet Box Mounting Hoods (Octagonal boxes for non-classified areas only) SEH and 3-1/4 or 4 Octagonal Outlet Box Mounting* Wall OBVW1 OBVW1-A Ceiling OBV1 OBV1-A GS Round Base Outlet Box Mounting orm 20** Wall GSW2 Ceiling GS2 JB Round Base Outlet Box Mounting** Wall JBW1 JBW1-A Ceiling JB1 JB1-A ixture Units Adapter/Socket, Globe and Guard W A-21 VU100M VU W PS-30 VU200M VU-200 Adapter/Socket and Globe W A-21 VU100MLG VU-100LG W PS-30 VU200MLG VU-200LG Adapter/Socket W A-21 VAD-1M VAD W PS-30 VAD-2M VAD-2 * Order SEH from catalog section A and octagonal from section OB. Screws, gasket and adapter plate furnished with fixture mounting hood. ** Order outlet box and gasket from catalog section A. Screws furnished with fixture mounting hood. Mounting hoods for wall installations can only be used with 30º angle reflectors. Accepts steel wire guard only. PAGE 19

20 2-20 V-51 Reflectors, Globes, Guards and Parts Description Catalog Number Glass Polycarbonate 60W-150W Glass VGU-2 150W-300W Glass 60W-100W Polycarbonate VPT-8 VWG-1 Standard Dome 30º Angle Glass and Polycarbonate Globes W W 100W Max.* Clear VGL-1CL VPG-1CL Amber VGL-1AM VPG-1AM Blue VGL-1BL VPG-1BL Green VGL-1GR VPG-1GR Opal VGL-1OP Red VGL-1RE VPG-1RE Clear Heat-Resistant VGL-1HR Glass Globes W W Clear VGL-2CL Amber VGL-2AM Blue VGL-2BL Green VGL-2GR Opal VGL-2OP Red VGL-2RE Clear Heat-Resistant VGL-2HR * Do not use in ambients exceeding 25 ºC. or burning in base-up position only. Aluminum Guards W A-21 (its VAD-1 Adapter) VGU W PS-30 (its VAD-2 Adapter) VGU-2 Steel Wire Guards W A-21 (its VAD-1M Adapter) VWG W PS-30 (its VAD-2M Adapter) VWG-2 Cannot be used with polycarbonate globes. Porcelain Reflectors urnished with neoprene attaching ring Standard Dome W A-21 VRW-1ST W PS-30 VRW-2ST 30 Angle W A-21 VRW-1AN W PS-30 VRW-2AN Replacement Reflector Attaching Ring (Neoprene) VPT-8 VPT-1AV Connection Block Lamp Socket (Medium Base) VPT-7 VPT-1AV VPT-7 Gasket for Lamp Socket and W Globe VPT-2 Gasket for W Globe VPT-3 VPT-2 VPT-3 VPT-4 Gasket for Mounting Hood VPT-4 PAGE 20

21 V-51 Dimensions 2-21 Type VA Types V, VC, VT and VX Type VXHA Types OBV and OBVW Types VGA and VGAT Type VD Types JB and JBW Types GS and GSW Dimensions Dimensions in Inches Dimensions in Centimeters Size A B C 1/2 & 3/4 D 1 & 1-1/4 D A B C 1/2 & 3/4 D 1 & 1-1/4 D W W Standard Dome 30 Angle Reflectors Standard Dome 30 Angle Inches centimeters Inches centimeters Size A B A B A B A B W W PAGE 21

22 2-22 Photometric data shown on this page is based on a 150-watt PS-25 lamp and is representative of the performance for all V-51 incandescent fixtures. or candlepower values of fixtures with other lamps, multiply the given candlepower values by the following multipliers: for 60 W A19 X 0.33; for 75 W A19 X 0.45; for 100 W A19 X 0.66; for 200 W PS25 X 1.44; and for 300 W PS30 X or candlepower values of fixture with guard, multiply by V-51 Photometric Data Suitable for use in wet locations. ull-size photometric data available for all V-51 fixtures on request. Without Reflector Effective loor Cavity Reflectance (Rfc) is 20% % Ceiling Rcc % Walls Rw ROOM CAVITY RATIOS Standard Dome Effective loor Cavity Reflectance (Rfc) is 20% % Ceiling Rcc % Walls Rw ROOM CAVITY RATIOS Angle PAGE 22

23 PVI Enclosed Non-Metallic Incandescent or use with Rigid Non-Metallic Conduit. Medium Base Applications Enclosed lighting fixtures for food processing plants, barns, garages, warehouses, workshops and other areas where moisture, dirt or corrosive atmospheres are a problem. Three designs suitable for use in general locations, damp locations or wet locations. or 60- to 150-watt A21 medium base incandescent lamps. or mounting directly to walls, ceilings or structural members. Ambient suitability in 0 ºC to 25 ºC. eatures ast, easy installation. Low initial and maintenance costs. Completely moisture- and corrosion-resistant construction no exposed metal parts. No separate outlet box needed. Base has four 1/2 or 3/4 threaded openings for conduit fittings. Glass globe screws out for easy bulb replacement and cleaning. External mounting lugs are super strong and impact-resistant. ixtures for use in general locations have a 15.0 cubic inch wiring compartment. ixtures for use in damp or wet locations have a 12.0 cubic inch wiring compartment. Up to 150-watt A21 medium base incandescent lamps. Standard Materials Socket: brass screw shell and center contact in high-temperature phenolic plastic base. Mounting hood/wiring compartment: impact-resistant reinforced polyester thermoplastic. Globes: clear heat-resistant glass. Guards: steel or vinyl-coated steel. Compliances UL Standard 1598 PVI1550, PVI1575, PVI1550D and PVI1575D for use with 60 ºC rated wire; PVI1550W and PVI1575W for use with 60 ºC rated wire. PAGE 23

24 2-24 PVI Enclosed Non-Metallic Incandescent or use with Rigid Non-Metallic Conduit. Medium Base. Size (Inches) Ceiling/Wall Mounting our Hubs W A-21 Medium Base Description Catalog Number 1/2 General Location PVI1550 3/4 PVI1575 1/2 Damp Location PVI1550D 3/4 PVI1575D 1/2 Wet Location (Enclosed and Gasketed) PVI1550W 3/4 PVI1575W Glass Globe W Clear Heat-Resistant VGL-1HR Wire Guards Replacement Lamp Socket Steel PVI-SGU Steel with Vinyl Coating (yellow) PVI-VCGU W A-21 Medium Base PVI-IS Dimensions Two mounting holes for up to 5/16 dia. bolts PAGE 24

25 REA Enclosed and Gasketed Incandescent 150 W* Inexpensive, Low-Wattage ixture for use in Wet Locations. UNILETS for use with Threaded Metal Conduit. Medium Base Applications Vaportight enclosed and gasketed lighting fixtures, suitable for use in wet locations. Standard glass globes take up to 150 W A-21 lamps. Optional polycarbonate plastic globes take up to 100 W A-21 lamps. eatures Inexpensive fixture designed for use without reflector. Spring-mounted shock-absorbing socket prolongs lamp life. Guards snap on easily and securely. Spring-action balls snap into detents in fixture body. Standard Materials Mounting bodies: pressure-cast copper-free aluminum. Socket: porcelain with brass screw shell. Guards: steel or aluminum guards. Standard inishes Mounting bodies: burnished. Steel wire guard: zinc electroplate. Aluminum guard: aluminum polymer enamel. Socket and globes: natural finish. Compliances UL Standard 1598 (Supersedes UL Standard 1571). Appleton malleable iron products conform to ASTM A47-77, Grade 32510, which has the following properties: tensile strength, 50,000 psi; yield, 32,000 psi; and elongation, 10%. Appleton aluminum products are produced from a high strength copper-free (4/10 of 1% max.) alloy. Description Hub Size (Inches) Catalog Number Pendant ixture 1/2 REA /4 REA-1075 Outlet Box ixture or 3-1/4 or 4 octagonal, or 4 square mounting. REA-10B Wall ixture REA-10LB Pendant Hood 1/2 REA-50 3/4 REA-75 Wall Bracket 1/2 male stem REA-1BR Lamp Socket VPLR-123 Steel Guard or Outlet Box fixture only. VWG-1 Aluminum Guard or Pendant and Wall Mount fixtures only. VGU-1 Colored Glass and Polycarbonate Globes Glass* Plastic* Clear VGL-1CL VPG-1CL Amber VGL-1AM VPG-1AM Blue VGL-1BL VPG-1BL Green VGL-1GR VPG-1GR Opal VGL-1OP Red VGL-1RE VPG-1RE Clear Heat-Resistant VGL-1HR *Maximum size A-21 lamp: glass globe 150 watts; plastic globe 100 watts. No reflectors are available for REA fixtures. PAGE 25

26 2-26 Stylmaster Strobe and Beacon Enclosed and Gasketed Applications Enclosed and gasketed fixtures suitable for use in marine and wet locations and in a wide range of industrial, chemical processing, and other areas where flammable gases and vapors are present under conditions defined by NEC Class I, Div. 2; Class II, Div. 1 and 2; and Class III. or use in areas where audible signals cannot be heard. Used to warn of unsafe conditions and other communication needs. ixtures are also suited for use in non-hazardous areas where severe weather conditions, excessive moisture, dirt, dust, corrosive atmospheres or high ambient temperatures are encountered. Typical applications include pulp and paper mills, processing plants, chemical plants, oil refineries, foundries, manufacturing plants, storage areas and marine applications eatures Modern styling, with clean-line mounting hood and prismatic glass globe, plus optional guard. Globe seats firmly against silicone gasket in mounting hood to keep out dirt and moisture. ull threads eliminate cross threading. Optional guard protects glass from damage and has exclusive snap-on attachment feature for quick installation and fast servicing. ixtures operate safely in high ambient temperatures. Strobe: 65 flashes per minute. Beacon: 75 rotations per minute. ixtures are complete with lamp. Lens available in five colors: red, amber, blue, green and clear (factory-installed). Heat- and impact-resistant globes have smooth dust-resistant exterior. ixture is suitable for mounting globe up or globe down utilizing pendant, ceiling or wall bracket type mounts. Minimum operating temperature is -25 C. ixtures are suitable for mounting in any position including globe up or globe down utilizing pendant, ceiling or wall bracket type mounts. Standard Materials Mounting hoods: copper-free aluminum. Guards: pressure-cast copper-free aluminum. Globes: prismatic glass. Standard inish Mounting hoods: powder coat epoxy. Aluminum guards: powder coat epoxy. Compliances Pendant Mount Class I, Div. 2, Groups A,B,C,D Class II, Div. 1 and 2, Groups E,,G Class III Type 3R and 4 Marine Outside Type (Saltwater) UL1604 UL1638 UL1203 Ceiling and Wall Bracket Mount Class I, Div. 2, Groups A,B,C,D Type 3R and 4 UL1604 UL1638 PAGE 26

27 Stylmaster Strobe and Beacon Enclosed and Gasketed 2-27 Ordering Information: Order using catalog numbering guide below or select catalog number from page CATALOG NUMBERING GUIDE OR STYLMASTER STROBE AND BEACON LUMINAIRES VP A S AC CL G SERIES: VP - Stylmaster MOUNTING HOOD; A - Pendant X - Ceiling WB - Wall Bracket TYPE: S - Strobe B - Beacon HUB SIZE: 75-3/4 VOLTAGE CURRENT: 120AC - 120VAC 240AC - 240VAC 1248DC VDC 24PDC - 24VDC* 250DC - 250VDC GLOBE: CL - Clear AM - Amber BL - Blue GR - Green RE - Red OPTIONS: G - Guard * Diode Polarized (current limiter supplied as standard). Technical Data: Thermal Suitability of Stylmaster Strobe and Beacon ixtures Operating Temperatures Ambient Temp. ( C) Class I, Div. 2 Groups A,B,C,D Pendant, Ceiling and Wall Bracket Class II, Div. 1& 2 and Class III Pendant Mount Strobe Beacon Strobe Beacon 40 T2A T1 T4A T4A 55 T2 464 T4A T4A 65 T1 474 T4 T4 Operating Temperatures Represent the Maximum Internal Temperature for Class I, Div. 2 Locations and Maximum Surface Temperature Under Dust Blanket for Class II, Div. 1 Locations. T Number T T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6 Temp Range ( C) NOTE: The maximum operating temperature of the fixture must not exceed the ignition temperature of the gas, vapor or dust to be encountered per NEC 500-5(e, f ). PAGE 27

28 2-28 Pendant Mount Class I, Div. 2, Groups A,B,C,D Class II, Div. 1 and 2, Groups E,,G Class III NEMA 3R, 4 Marine Outside Type (Saltwater) UL1604, UL1638, UL1203 Ceiling and Wall Bracket Mount Class I, Div. 2, Groups A,B,C,D NEMA 3R, 4 UL1604, UL1638 Stylmaster Strobe and Beacon Enclosed and Gasketed ixtures and Weights Ordering Information Volts Wt. lbs. Catalog Number* Pendant Strobe 120VAC 4.5 VPAS75120ACCL Rigid Conduit 240VAC VPAS75240ACCL One Hub 3/4 NPT 250VDC VPAS75250DCCL 12-48VDC VPAS751248DCCL 24VDC VPAS7524PDCCL** Beacon 120VAC 4.0 VPAB75120ACCL 240VAC VPAB75240ACCL Ceiling Strobe 120VAC 5.3 VPXS75120ACCL Rigid Conduit 240VAC VPXS75240ACCL our Hubs 3/4 NPT Three Close-Up Plugs 250VDC VPXS75250DCCL 12-48VDC VPXS751248DCCL 24VDC VPXS7524PDCCL** Beacon 120VAC 4.2 VPXB75120ACCL 240VAC VPXB75240ACCL Wall Bracket Strobe 120VAC 6.4 VPWBS75120ACCL Rigid Conduit 240VAC VPWBS75240ACCL our Hubs 3/4 NPT Three Close-Up Plugs 250VDC VPWBS75250DCCL 12-48VDC VPWBS751248DCCL 24VDC VPWBS7524DCCL** Beacon 120VAC 5.2 VPWBB75120ACCL 240VAC VPWBB75240ACCL Optional Aluminum Guard Strobe and Beacon 1.0 lbs. VPGU-1 * Catalog numbers shown are supplied with clear lens. To order colored lens, replace the last digits of catalog number CL with AM for amber, BL for blue, GR for green or RE for red. **Diode Polarized (current limiter supplied as standard). PAGE 28

29 Stylmaster Strobe and Beacon Replacement Parts and Dimensions AC S865 Replacement Lamps ixture Type Lamp Type Voltage Wattage Base Type Catalog Number Beacon Halogen 120VAC 40W DBL Bayonet Q4OA9-120AC Beacon Halogen 24-28VDC 18W DBL Bayonet Q20A-24VDC Beacon Incand. 240VAC 25W DBL Bayonet AC Strobe Xenon All Octal Socket S865 Q4OA9-120AC Q20A-24VDC Replacement Globes and Inserts Glass Globe for Beacon Clear Amber Blue Green Red Catalog Number VPGL-1HR VPGL-1AM VPGL-1BL VPGL-1GR VPGL-1RE Glass Globe for Strobe Catalog Number Insert or Strobe Only (In addition to Glass Globe) Clear VPGL-1HR Clear Amber Blue Green Red Dimensions Pendant Mount Ceiling Mount Wall Mount PAGE 29

Applications. Illustrated Features. Certifications and Compliances

Applications. Illustrated Features. Certifications and Compliances Stylmaster Incandescent Luminaires NEC: CSA: V Class II, Division 1 and 2, Groups E, F, G Class III Enclosure 4X Lighting Lighting: Area Incandescent Applications Enclosed and gasketed lighting fixtures

More information

A-51 Incandescent Factory Sealed Luminaires Explosionproof Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.

A-51 Incandescent Factory Sealed Luminaires Explosionproof Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit. Explosionproof NEC/CEC For Group A and B: Class I, Division 1 and 2, Groups A, B, C, D NEC/CEC For Group C and D: Applications A-51 Series Incandescent Class I, Groups A, B, C and D; and Class II, Groups

More information

FLUORESCENT/AREA: NEC/CEC EXPLOSIONPROOF. Applications. Illustrated Features

FLUORESCENT/AREA: NEC/CEC EXPLOSIONPROOF. Applications. Illustrated Features Applications Ideal for use in chemical and petrochemical plants, such as manufacturers of plastics, paints and thinners; in refineries; and in other process areas where ignitable vapors, dust, moisture

More information

Class II, Division 1 and 2, Groups E, F, G Class III CSA 4X

Class II, Division 1 and 2, Groups E, F, G Class III CSA 4X Applications For use in hazardous locations such as plants where plastics, paints, thinners and petrochemicals are manufactured, and in other areas where ignitable vapors, dust, moisture and corrosive

More information

Mercmaster LED Low Profile Luminaires with Emergency Battery Backup Enclosed and Gasketed Fixtures

Mercmaster LED Low Profile Luminaires with Emergency Battery Backup Enclosed and Gasketed Fixtures Class I, Division, Groups A,B,C,D Class I, Zone, Group IIC Zone, Group IIIC Class II, Division, Groups F,G Applications Enclosed and gasketed fixtures suitable for use in: A wide range of industrial, chemical

More information

AVP SERIES Aluminum Lighting for Hazardous and Severe Environments

AVP SERIES Aluminum Lighting for Hazardous and Severe Environments AVP SERIES Aluminum Lighting for Hazardous and Severe Environments A V P Class I, Division 2, Groups A, B, C & D Zone 2, Group IIA, IIB, IIC UL 844 Hazardous Locations UL 1598A Marine Outside Type CUL

More information

Baymaster HL LED Luminaire High Bay for Hazardous Locations

Baymaster HL LED Luminaire High Bay for Hazardous Locations Class I, Division, Group A, B, C, D Class I, Zone, Group IIC Class II, Division &, Group E, F, G Zone and Group IIIC Zone Group IIIB Applications Enclosed and gasketed fixtures suitable for use in: A wide

More information

EVLP Low Profile Hazard Gard (H.I.D.) Luminaires

EVLP Low Profile Hazard Gard (H.I.D.) Luminaires EVLP Low Profile (H.I.D.) Luminaires Medium and Cl. I, Div. 1, Groups B (GB suffix), C, D Cl. I, Zone 1, Groups IIB + H2 (with suffix GB), IIB, IIA Cl. II, Div. 1, Groups E, F, G; Class III Marine & Wet

More information

Baymaster LED Luminaire High Bay for Hazardous Locations

Baymaster LED Luminaire High Bay for Hazardous Locations Class I, Division, Group A, B, C, D Class I, Zone, Group IIC Class II, Division &, Group E, F, G Zone and Group IIIC Zone Group IIIB Applications Enclosed and gasketed fixtures suitable for use in: A wide

More information

Description Cast Device Box, Height Inch; Width 2.81 Inch; Depth 2.69 Inch; Capacity 25 Cu Inch; 1 Gang; 2 Hub(S); Hub Location End;

Description Cast Device Box, Height Inch; Width 2.81 Inch; Depth 2.69 Inch; Capacity 25 Cu Inch; 1 Gang; 2 Hub(S); Hub Location End; 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 1100 1G Mall Box Appleton/Oz Gedney Catalog Number 1100 Manufacturer Appleton/Oz Gedney Description Cast Device Box, Height

More information

Cl. I, Div. 1, Group B (with suffix GB), C, D Cl. I, Zone 1, Group IIB + H2

Cl. I, Div. 1, Group B (with suffix GB), C, D Cl. I, Zone 1, Group IIB + H2 EVLS Hazard Gard A compact, affordable, explosionproof luminaire that has the best overall temperature performance ratings in its class! Eaton's Crouse-Hinds EVLS Hazard Gard is perfect as a general area

More information

Areamaster Generation 2 HL LED Luminaire Floodlight for Hazardous Locations

Areamaster Generation 2 HL LED Luminaire Floodlight for Hazardous Locations Areamaster Generation HL LED Luminaire Class I, Division, Groups A, B, C, D Class I, Zone Group IIC Class II, Division and, Groups E, F, G Zone and Group IIIC Zone, Group IIIB Type R,, X, IP66/67 Applications

More information

BVP SERIES Brass Lighting for Marine and Hazardous Environments

BVP SERIES Brass Lighting for Marine and Hazardous Environments BVP SERIES Brass Lighting for Marine and Hazardous Environments Class I, Division 2, Groups A, B, C & D Zone 2, Group IIA, IIB, IIC UL 844 Hazardous Locations UL 1598A Marine Outside Type NEMA 3, 4, 4X

More information

10 Hazlux Lighting US Brochure

10 Hazlux Lighting US Brochure 0 Hazlux Lighting US Brochure Area lighting Hazlux 3 series Safe, durable, and now available with LED technology for superior energy efficiency, Thomas & Betts Hazlux products are the brand specifiers

More information

FSK1VDRA 1G Al DPLX RCPT CVR

FSK1VDRA 1G Al DPLX RCPT CVR 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 FSK1VDRA 1G Al DPLX RCPT CVR Appleton/Oz Gedney Catalog Number Manufacturer Weight per unit Product Category FSK1VDRA

More information

Industrial Mercmaster LED Generation 3 Series Luminaires For Ordinary Locations

Industrial Mercmaster LED Generation 3 Series Luminaires For Ordinary Locations Industrial Mercmaster LED Generation Series Luminaires Applications Powerful, efficient weatherproof lighting suitable for use in: Warehouses Storage facilities Machine shops Receiving areas Manufacturing

More information

COMMERCIAL AND INDUSTRIAL FITTINGS: CAST DEVICE BOXES. Applications

COMMERCIAL AND INDUSTRIAL FITTINGS: CAST DEVICE BOXES. Applications Blank Bodies for Brazed Hubs UNILETS for Use with Threaded Rigid Metal Conduit and IMC. Available with Hub Sizes from 1/2 through 1-1/2 (Union 1/2 through 1-1/4 ). Furnished with Internal Ground Screw.

More information

Bullet EL Volt Die-Cast Aluminum, PAR38 Incan. / Halogen / R40 Incan. revision 8/15/11 el220.pdf

Bullet EL Volt Die-Cast Aluminum, PAR38 Incan. / Halogen / R40 Incan. revision 8/15/11 el220.pdf Catalog number: and Finish Options: See page 2 ing Options: See pages 3-5 Approvals: Date: Page: 1 of 5 Specifications Housing: Die-cast low copper aluminum. Swivel: Die-cast aluminum with locking teeth

More information

AGUB Instrument and Meter Enclosures Explosionproof, Dust-Ignitionproof Furnished with aluminum body and solid or window cover.

AGUB Instrument and Meter Enclosures Explosionproof, Dust-Ignitionproof Furnished with aluminum body and solid or window cover. AGUB Instrument and Meter Enclosures Furnished with aluminum body and solid or window cover. Class I, Division 1 and, Groups B, C, D Application To pull or splice wires and/or to mount and enclose electrical

More information

Class 1 Division 2 Fluorescent Light - 4 foot 2 lamp - UV bulbs - Glass Lens

Class 1 Division 2 Fluorescent Light - 4 foot 2 lamp - UV bulbs - Glass Lens Class 1 Division 2 Fluorescent Light - 4 foot 2 lamp - UV bulbs - Glass Lens Part #: HAL-48-2L-BL-UV Made in Texas The Larson Electronics HAL-48-2L-BL-UV Hazardous Location Ultraviolet Fluorescent Light

More information

Industrial Areamaster Generation 2 HL LED Luminaire Floodlight for Ordinary Locations

Industrial Areamaster Generation 2 HL LED Luminaire Floodlight for Ordinary Locations Industrial Areamaster Generation HL LED Luminaire Type R,, X Applications Powerful, efficient weatherproof lighting for applications such as: Security lighting Production facilities Warehouses Processing

More information

Class 1 Division 2 Fluorescent Light - 2 Foot 3 Lamp - Corrosion Resistant Requirements

Class 1 Division 2 Fluorescent Light - 2 Foot 3 Lamp - Corrosion Resistant Requirements Class 1 Division 2 Fluorescent Light - 2 Foot 3 Lamp - Corrosion Resistant Requirements Part #: HALP-24-3L Made in the USA The Larson Electronics HALP-24-3L Hazardous Area Fluorescent Light Fixture is

More information

commercial and industrial fittings: cast DEVICE BOXES Applications Illustrated Features

commercial and industrial fittings: cast DEVICE BOXES Applications Illustrated Features UNILETS for use with Threaded Rigid Conduit and IMC. All Device Boxes have Construction. Furnished with Internal Ground Screw. Applications Accommodate wiring devices such as switches and receptacles.

More information

EVLS Hazard Gard. Compact & Rugged, Explosionproof Luminaire. High-Pressure Sodium Metal Halide Pulse Start Metal Halide

EVLS Hazard Gard. Compact & Rugged, Explosionproof Luminaire. High-Pressure Sodium Metal Halide Pulse Start Metal Halide Compact & Rugged, Explosionproof Luminaire Class I, Division 1, Groups B (with suffi x GB), C & D Class I, Zone 1, Group IIB + H 2 (with suffi x GB) Class II, Class III & Simultaneous Presence Wet locations

More information

Spun Copper Bullet C to 277 Volt Spun Copper LED revision 11/7/14 kl_c24led_spec.pdf

Spun Copper Bullet C to 277 Volt Spun Copper LED revision 11/7/14 kl_c24led_spec.pdf Catalog number: ing Options: Ordered Separately from See pages 3-5 Approvals: Date: Page: 1 of 5 Specifications 6K" DIA. (165.1 mm) Ordering Information 13J" (336.6 mm) K" NPT 2B" (54.0 mm) Source l S3/9L3KUV

More information

Lowlighter KLV Volt Die-Cast Brass, MR16 Halogen revision 2/25/14 kl_klv275_spec.pdf. Ravenna TM. Specifications. Approvals: Type: Job:

Lowlighter KLV Volt Die-Cast Brass, MR16 Halogen revision 2/25/14 kl_klv275_spec.pdf. Ravenna TM. Specifications. Approvals: Type: Job: Catalog number: and Finish Options: See page 2 : See pages 3-5ˇ Approvals: Date: Page: 1 of 5 Specifications Lamp Housing: Die-cast brass with die-cast cover, stainless steel fasteners and stainless steel

More information

Exterior Decor LIGHTING. Bulkheads. architectural lighting. See our Bulkhead family sizes. Over 50 styles to choose from.

Exterior Decor LIGHTING. Bulkheads. architectural lighting. See our Bulkhead family sizes. Over 50 styles to choose from. LIGHTING FC Lighting is known for it s family-size products and custom manufacturing capabilities, both are unique in adding vslue to our customers. Specification is made easier choosing various sized

More information

AERODOME PARKING/ROADWAY (TYPE III)

AERODOME PARKING/ROADWAY (TYPE III) SIDE-ARM MOUNT AERODOME PARKING/ROADWAY (TYPE III) AVV30-20 Lampholder Optic Housing Seamless, die-cast aluminum Reflector Segmented aluminum sheet with highly efficient finishes Lamp Lens High impact,

More information

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4 I N D U S T R I A L rev. A- INSTALLATION INSTRUCTIONS *PENDING* E77827 E77827 APPLICATION MR3 & MR6 Luminaires are suitable for use in the following areas as defined by the National Electrical Code (NEC)

More information

Micro-Flood EL / 277 Volt Die-Cast Aluminum LED revision 4/11/11 el217.pdf

Micro-Flood EL / 277 Volt Die-Cast Aluminum LED revision 4/11/11 el217.pdf Catalog number: / Mode Options: See page 2 ing Options: See pages 3-5 Approvals: Date: Page: 1 of 5 Specifications Housing and Lens Frame: Die-cast low copper alloy (

More information

General Information...SA1-SA4

General Information...SA1-SA4 SECTION S INDEX Product Description Page Number General Information................................................................SA1-SA4 Type FSK Thruwall & Floor Seal For Conduit, Pipe or Tubing............................

More information

DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications. Patent Pending

DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications. Patent Pending Patent Pending DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications DuroSite Series LED High Bay Features & Benefits L70 rated for >100,000 hours @ 45 C ambient 5 year full performance

More information

Thru Wall Floor Seals For New Installation

Thru Wall Floor Seals For New Installation The O-Z/Gedney Thruwall and Floor Seals provide a positive means of sealing pipe, conduit or tube where they pass through a concrete foundation of a structure below grade or below ground water level or

More information

Floor Boxes. Concealed Service Floor Boxes. Engineering Data 663 Series. Faces Plates for 663 Floor Box. 663 Series Floor Box

Floor Boxes. Concealed Service Floor Boxes. Engineering Data 663 Series. Faces Plates for 663 Floor Box. 663 Series Floor Box Concealed Service Floor Boxes 663 Series Floor Box 663-SC Multiple service floor box that delivers power, communications and data from standard conduit with no exposed service fitting Result: Open office

More information

INSTALLATION INSTRUCTIONS F Series Floodlight

INSTALLATION INSTRUCTIONS F Series Floodlight IMPORTANT: Read carefully before installing. All work should be performed by a qualified Electrician. These instructions may not provide directions to cover every variation and detail. To obtain additional

More information

ceiling. slots and strain clamps. *For custom baffle, reflector, trim ring, glass color and lens options, please consult factory.

ceiling. slots and strain clamps. *For custom baffle, reflector, trim ring, glass color and lens options, please consult factory. 10 (254 mm) 12-24 (305 mm - 610 mm) (184 mm) 6-1/2 (165 mm) 7 (178 mm) A B E C D New construction, thermally protected, IC rated specification grade recessed housing. Accommodates up to 75W PAR30, R30

More information

DISCONTINUED. LTV10 Series Composite Housing Accent. Specifications. Lightvault. Type: Job: Catalog number: Approvals: Fixture Options: / / /

DISCONTINUED. LTV10 Series Composite Housing Accent. Specifications. Lightvault. Type: Job: Catalog number: Approvals: Fixture Options: / / / Catalog number: Specifications 16J" (412.8 mm) 2B" (54.0 mm) Hubbell Lighting, Inc. / / / Fixture Optics Lamp Mode Option - order assembled with fixture See page 2 See page 3 L" (19.1 mm) 13J" (336.6 mm)

More information

Explosion Proof Fluorescent Ultraviolet Light - Class 1 & 2-4' 2 lamp - Paint Booths, Rigs, Marine

Explosion Proof Fluorescent Ultraviolet Light - Class 1 & 2-4' 2 lamp - Paint Booths, Rigs, Marine Explosion Proof Fluorescent Ultraviolet Light - Class 1 & 2-4' 2 lamp - Paint Booths, Rigs, Marine Part #: EPL-48-2L-UV Made in the USA The Larson Electronics EPL-48-2L-UV Explosion Proof UV Fluorescent

More information

1000 Watt Metal Halide Light - Hot Restrike - Multi-tap Ballast - Spot or Flood

1000 Watt Metal Halide Light - Hot Restrike - Multi-tap Ballast - Spot or Flood 1000 Watt Metal Halide Light - Hot Restrike - Multi-tap Ballast - Spot or Flood Part #: HID-22SL-HR The HID-22SL-HR 1000 Watt Metal Halide Light from Larson Electronics provides operators with the intensity

More information

This specification describes the minimum requirements for service water piping systems (ie: cooling water, process water, etc.), located on surface.

This specification describes the minimum requirements for service water piping systems (ie: cooling water, process water, etc.), located on surface. SPEC-3500 1/9 1.0 PURPOSE This specification describes the minimum requirements for service water piping systems (ie: cooling water, process water, etc.), located on surface. Note: This specification does

More information

RSB-RCS/L SERIES The RSB-RCS/L Series rectangular shoebox is offered in a variety of lighting distributions with sharp cutoff to meet the challenging demands of today s site lighting projects. Fixture

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS SHD TO REMOVE HOOD (SHD) ) LOOSEN (4) SOCKET HEAD SCREWS AND RETAINING RINGS FROM HOOD (SHD). ) REMOVE HOOD AND. 3) DISCONNECT WIRES. 3 4) REMOVE REFLECTOR BY LOOSENING (4) PHILIPS HEAD SCREWS. 5) PLEASE

More information

THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS. LumeLEX 2026 SERIES INSTALLATION INSTRUCTIONS Important THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS. Warning This product must be installed in accordance with National Electrical

More information

MATERIAL COMBINATION NUMBER 2: Corrosive environment requiring harder, wear-resistant seating faces and resistance to dezincification.

MATERIAL COMBINATION NUMBER 2: Corrosive environment requiring harder, wear-resistant seating faces and resistance to dezincification. Cast Iron Slide Gates Spec Sheet General The contractor shall furnish and install the following cast iron slide gate assemblies as listed on the Gate Schedule and detailed on the manufacturer s drawings.

More information

Conduit End Bells...EA1 Hex Reducing Bushings...EA2 Conduit Hubs...EA3-EA4. Split Couplings...EA5 Three Piece Couplings...EA6 Conduit Nipples...

Conduit End Bells...EA1 Hex Reducing Bushings...EA2 Conduit Hubs...EA3-EA4. Split Couplings...EA5 Three Piece Couplings...EA6 Conduit Nipples... SECTION E INDEX Product Description Page Number Conduit End Bells.......................................EA Hex Reducing Bushings..................................EA2 Conduit Hubs......................................EA-EA4

More information

IL 3525 Series. LED Industrial Lighting. Advantages of IL3525. Application

IL 3525 Series. LED Industrial Lighting. Advantages of IL3525. Application LED Industrial Lighting Advantages of IL3525 Proprietary Reflector and Optics enabling glare-free uniform lighting for all working environments. Eliminating the need for costly and fragile plastic lenses

More information

Introducing the SIGNATURE SERIES

Introducing the SIGNATURE SERIES Introducing the SIGNATURE SERIES Function Meets Form Using the ancient artform of metal spinning, Signature Series fixtures are available in your choice of base metals: aluminum, brass, copper or galvanized

More information

SECTION LIGHTING FIXTURES AND LAMPS

SECTION LIGHTING FIXTURES AND LAMPS SECTION 16511 LIGHTING FIXTURES AND LAMPS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 09200 - Metal Studs, Lath, Suspension Ceiling, Plaster, and Stucco. 2. 09510 - Acoustical Ceilings. 3. 16112

More information

(SMS MOUNT SHOWN) Prefix Mounting Optics Lamp Wattage Length Volts Finish Options & Accessories 14W 21W 28W 2' 3', 6' 4', 8' T5HO 2' 3', 6' 4', 8'

(SMS MOUNT SHOWN) Prefix Mounting Optics Lamp Wattage Length Volts Finish Options & Accessories 14W 21W 28W 2' 3', 6' 4', 8' T5HO 2' 3', 6' 4', 8' (SMS MOUNT SHOWN) Prefix Mounting Optics Lamp Wattage Length Volts Finish Options & Accessories SMS - surface mount single fixture SMM - surface mount multiple fixtures EAS - extended arm single fixture

More information

Signal Beacon - LED Series 6162

Signal Beacon - LED Series 6162 www.stahl.de > Versions rotating mirror beacon rotating beacon beacon with double flash (9 + 5 J) flashing beacon (15 J) LED-continuous beacon LED-rotating beacon > Seawater resistant aluminium enclosure

More information

LOW LEVEL LE1/2/3. Lantern Bollard. Era. For pathways, courtyards and entrances.

LOW LEVEL LE1/2/3. Lantern Bollard. Era. For pathways, courtyards and entrances. LOW LEVEL LE1/2/3 Era Lantern Bollard For pathways, courtyards and entrances. Era Lantern Bollard Series TABLE OF CONTENTS Proportion Guide Specifications Ordering Information Photometrics Lamp and Electrical

More information

Ground Clamps Cable Tray

Ground Clamps Cable Tray commercial and industrial fittings: ing Fittings and Solderless Connectors Clamps Cable Tray Terminates ground wire to cable tray. For aluminum or copper conductors. 1 4 hex wrench tightens both tray and

More information

Series 5 Die Cast Aluminum Conduit Outlet Bodies, Covers and Gaskets

Series 5 Die Cast Aluminum Conduit Outlet Bodies, Covers and Gaskets Eaton's Crouse-Hinds Series 5 die cast copper-free aluminum conduit bodies, covers and gaskets are available for use with rigid or EMT conduit (with set screw). Conduit bodies are available in trade sizes

More information

UL / FM E-1 FIRE PROTECTION PRODUCTS INDICATOR POST FEATURES. *Applies to "ORDER LENGTH" codes B through F; code A has 22" adjustment.

UL / FM E-1 FIRE PROTECTION PRODUCTS INDICATOR POST FEATURES. *Applies to ORDER LENGTH codes B through F; code A has 22 adjustment. UL / FM MUELLER Indicator Post are used in fire protection systems and perform several functions. The Indicator Post provides a means to operate a buried or otherwise inaccessible valve. Also, the Indicator

More information

Series 80 In-Line Mounted Centrifugal Pumps

Series 80 In-Line Mounted Centrifugal Pumps Bulletin B-G Bell & Gossett Series In-Line Mounted Centrifugal Pumps Applications Hydronic Heating & Cooling Systems Industrial Process General Service Pressure Boosting Advantages Close Coupled Space

More information

VM5 CATALOG ORDERING LOGIC

VM5 CATALOG ORDERING LOGIC KILLARK VM5 CATALOG ORDERING LOGIC CertiLite Catalog Number Logic; 200- High Wattage (Mogul Base) HID Fixtures VM 0 0 00 0 0 0 00 0 (NRn) 00 Series Constant Optic Thread Size 5 7 Lamp Type S HPS (200,,,

More information

FIRE PROTECTION PRODUCTS

FIRE PROTECTION PRODUCTS FEATURES Rev. 7-11 Mueller Indicator Post are used in fire protection systems and perform several functions. The Indicator Post provides a means to operate a buried or otherwise inaccessible valve. Also,

More information

EPL-48-1L Surface Mount Explosion Proof, Waterproof Fluorescent Lights -Paint Booth, Rigs - 1 Lamp -

EPL-48-1L Surface Mount Explosion Proof, Waterproof Fluorescent Lights -Paint Booth, Rigs - 1 Lamp - EPL-48-1L Surface Mount Explosion Proof, Waterproof Fluorescent Lights -Paint Booth, Rigs - 1 Lamp - Part #: EPL-48-1L Page: 1 Made in Texas The Larson Electronics EPL-48-1L Explosion Proof Fluorescent

More information

PIPE/CONDUIT SUPPORTS

PIPE/CONDUIT SUPPORTS PIPE/CONDUIT SUPPORTS Pipe/Conduit Clamps...102-105 Unicushion... 106 Pipe & Tubing (Cush-A-Clamp ) Clamps...107-110 Pipe Hangers... 111 Pipe Rollers...111-112 Pipe Brackets... 113 Reference Tables...114-120

More information

HP 2 SERIES Integral Driver - Solid State LED

HP 2 SERIES Integral Driver - Solid State LED HP 2 SERIES Installation Instructions Warning High Voltage Hot Surface NEEDED FOR INSTALLATION: By Others 1/8 & 5/32 Allen Wrench Waterproof Wire Connectors Level Phillips Screwdriver IMPORTANT - WEAR

More information

Direct Burial Floodlight - DBF Installation Instructions Above Grade Housing

Direct Burial Floodlight - DBF Installation Instructions Above Grade Housing P.O. Box 60080 16555 East Gale Ave. City of Industry, California 91716-0080 626/968-5666 FAX 626/330-3861 Direct Burial Floodlight - DBF Installation Instructions DBF10 / DBF710 WARNING: Fixtures must

More information

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box Applications Food and beverage industry Pharmaceutical industry Biotechnology industry Cosmetic industry Special Features Meets

More information

50ft Temporary String Light - Five LED Work Lamps - 50 Watt LED Stringer - 12/3 SJTW - Twist Lock

50ft Temporary String Light - Five LED Work Lamps - 50 Watt LED Stringer - 12/3 SJTW - Twist Lock 50ft Temporary String Light - Five LED Work Lamps - 50 Watt LED Stringer - 12/3 SJTW - Twist Lock Part #: WAL-SL-5-LED-12.3-TLP Page: 1 The Larson Electronics WAL-SL-5-LED-12.3-TLP Work Area Lighting LED

More information

SeriesTWO RGB Fluorescent Fixtures. Installation and Instruction Manual

SeriesTWO RGB Fluorescent Fixtures. Installation and Instruction Manual SeriesTWO RGB Fluorescent Fixtures Installation and Instruction Manual Brightline LP 580 Mayer Street #7, Bridgeville PA 15017 Phone 1-412-206-0106 Fax 1-412-206-0146 www.brightlines.com The Brightline

More information

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V) FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V) 21T, Rev.4 6-13 IMPORTANT: Before proceeding, retrieve the GLASS SHADE INSTALLATION GUIDE, which is included with the pendant cord set

More information

INSTALLATION INSTRUCTIONS IMPORTANT SAFEGUARDS SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS IMPORTANT SAFEGUARDS SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS MILLENIUM ROUND Luminaire for High Abuse Applications SEMI-RECESSED PROFILE SERIES INSTALLATION INSTRUCTIONS 1 IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always

More information

AREA LIGHTING HYPAK SERIES HYPAK - HP3 HYPAK - HP4

AREA LIGHTING HYPAK SERIES HYPAK - HP3 HYPAK - HP4 AREA LIGHTING HYPAK SERIES HYPAK - HP3 HYPAK - HP4 Hypak Area Lights - HP3 and HP4 Hypak - a series of high performance building mounted luminaires providing maximum versatility. Innovative optical design,

More information

Lightplane 3.5 Recessed

Lightplane 3.5 Recessed INSTALLATION INSTRUCTIONS Lightplane 3.5 Recessed LP3.5R Recessed Ceiling IMPORTANT SAFETY INSTRUCTIONS When installing or using this fixtures basic safety precautions must be followed. Read all instructions

More information

This specification describes the minimum requirements for piping systems for the following service:

This specification describes the minimum requirements for piping systems for the following service: 201/11/2 1/9 1.0 APPLICATION This specification describes the minimum requirements for piping systems for the following service: Underground Service Water Note: This specification does not apply to piping

More information

E LED Lighting BV & Inc. European Office: Tel: +31 (0) , Fax +31 (0) , E mail LEDLighting.com United States Office:

E LED Lighting BV & Inc. European Office: Tel: +31 (0) , Fax +31 (0) , E mail LEDLighting.com United States Office: HIGH POWER LED LIGHTS LED Flood Lights LED Floodlights operate efficiently and save power but also reduce maintenance and service costs as a result of their long life. Conventional floodlights require

More information

RAIL 4 INSTALLATION INSTRUCTIONS. RM4DOD Recessed GENERAL SAFETY INSTRUCTIONS: NOTE:

RAIL 4 INSTALLATION INSTRUCTIONS. RM4DOD Recessed GENERAL SAFETY INSTRUCTIONS: NOTE: INSTALLATION INSTRUCTIONS RAIL 4 RM4DOD Recessed NOTE: The following instructions provide general guidelines for product installation. For additional information consult the applicable electrical codes

More information

100ft Temporary Construction String Light - Ten LED Work Lamps Watt LED Stringer - 12/3 SJTW

100ft Temporary Construction String Light - Ten LED Work Lamps Watt LED Stringer - 12/3 SJTW 100ft Temporary Construction String Light - Ten LED Work Lamps - 100 Watt LED Stringer - 12/3 SJTW Part #: WAL-SL-10-LED-12.3 Page: 1 The Larson Electronics WAL-SL-10-LED-12.3 Work Area Lighting LED String

More information

FIELD DEVICES PRESSURE

FIELD DEVICES PRESSURE FIELD DEVICES PRESSURE Product Specifications Models 11GM and 11GH Pneumatic Transmitters for Gauge Pressure Measurement 11GM TRANSMITTER 11GH TRANSMITTER The Foxboro brand Models 11GM and 11GH Transmitters

More information

Square Straight Steel - 4 Bolt Base Light Poles

Square Straight Steel - 4 Bolt Base Light Poles Quick Ship Square Bronze over Galvanized Straight Steel Pole - 4 Bolt Base Square Straight Steel - 4 Bolt Base Light Poles Optional Tenon Mounting (specify) "D" Top Diameter Arm Drilling Per Customer Specs.

More information

Lux-Ray LED Series Low-profile, sleek look light fixture NEMA-3R

Lux-Ray LED Series Low-profile, sleek look light fixture NEMA-3R 102 EMERGI-LITE REMOTE FIXTURES Lux-Ray LED Series Low-profile, sleek look light fixture Optional high-lumen output Optional photo-switch: dusk-to-dawn control of normal lighting Optional remote test:

More information

Moveable Workstations. Enterprise KEWAUNEE. encouraging new discovery...worldwide

Moveable Workstations. Enterprise KEWAUNEE. encouraging new discovery...worldwide Enterprise Moveable Workstations KEWAUNEE encouraging new discovery...worldwide Movable Workstations Self-supporting workstations Single and double sided Adjustable height worksurfaces Integrated shelving

More information

This specification describes the minimum requirements for piping systems for the following service:

This specification describes the minimum requirements for piping systems for the following service: SPEC-3004 1/7 1.0 APPLICATION This specification describes the minimum requirements for piping systems for the following service: Service Water Design Conditions Operating Conditions 10 PSIG @ 33 o F to

More information

RELINER INSIDE DROP SYSTEM SPECIFICATIONS

RELINER INSIDE DROP SYSTEM SPECIFICATIONS 1. PRODUCT NAME RELINER INSIDE DROP SYSTEM U.S. Patent 6074130 Canadian Patent # 2269565 All RELINER Products are proudly made in the U.S.A. 2. MANUFACTURER RELINER /Duran Inc. 53 Mount Archer Rd. Lyme

More information

Bulletin 800H Hazardous Location Push Buttons Product Overview/Specifications. Table of Contents See below.

Bulletin 800H Hazardous Location Push Buttons Product Overview/Specifications. Table of Contents See below. Bulletin H Product verview/specifications Bulletin H/ Hazardous locations push buttons and stations Classes I, II & III Divisions & / in. - NPSM barrel Type & Explosion-proof operators Table of Contents

More information

VG Series LED Parking Structure Luminaire

VG Series LED Parking Structure Luminaire VG Series LED Parking Structure Luminaire Used for Pendant, Hook & Cord, Junction Box, Direct and Trunnion Mounts Reinventing LED Parking Structure Lighting ENHANCED DRAMATIC PLEASING QUICK AND RELIABLE

More information

Part Number: Ordering Example: VVDBLFL UNV CL-AR1 UNV V UNV V*

Part Number: Ordering Example: VVDBLFL UNV CL-AR1 UNV V UNV V* Product Description Available with a variety of designated optic distributions, efficient Osram P8 LEDS, and powered by a Meanwell driver, this series offers superior quality of light and full flexibility

More information

FUEL GAS PIPING SECTION A. The provisions of SECTION 15010, MECHANICAL GENERAL REQUIREMENTS, apply to this section.

FUEL GAS PIPING SECTION A. The provisions of SECTION 15010, MECHANICAL GENERAL REQUIREMENTS, apply to this section. FUEL GAS PIPING SECTION 15355 PART 1 GENERAL 1.1 DESCRIPTION A. The provisions of SECTION 15010, MECHANICAL GENERAL REQUIREMENTS, apply to this section. B. This specification covers both interior and exterior

More information

Stargrip series 3000 Mechanical Joint Wedge Action Restraint for Ductile Iron Pipe

Stargrip series 3000 Mechanical Joint Wedge Action Restraint for Ductile Iron Pipe Stargrip series 3000 Mechanical Joint Wedge Action Restraint for Ductile Iron Pipe INFORMATION The Stargrip Mechanical Joint Restraint System is a unique product with a proven design that provides an exceptional

More information

INDIRECTTM. Cubic INDIRECT INDIRECT/CUBIC INDIRECT

INDIRECTTM. Cubic INDIRECT INDIRECT/CUBIC INDIRECT INDIRECTTM Cubic INDIRECT TM A R C H I T E C T U R A L A R E A L I G H T I N G INDIRECT/CUBIC INDIRECT 1 to create, inspire and nurture EXCELLENCE in each other ENERGY EFFICIENCY The light sources employed

More information

1.3. Pushbuttons and Indicating Lights.

1.3. Pushbuttons and Indicating Lights. .3 Pushbuttons and Indicating Lights Pushbutton Control Stations Contents Page Features.............................. V7-T-5 Product Selection M22 Assembled Control Stations........ V7-T-6 Commercial Control

More information

SECTION LIGHTING PART 1- GENERAL

SECTION LIGHTING PART 1- GENERAL SECTION 16500 LIGHTING PART 1- GENERAL 1.01 WORK INCLUDED A. The Contractor shall provide all lighting fixtures, panelboards, labor, material, etc., in accordance with the preceding specifications, the

More information

SECTION LIGHTING

SECTION LIGHTING SECTION 16500 - LIGHTING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Visit our web site:

Visit our web site: Compliance and Applications ICAO Annex NATO STANAG BS: Part, inset fixtures IEC: Category I, II and III all weather operation airfield lighting systems. Our ZA medium intensity, omnidirectional fixture

More information

January 27, Our Product Offering

January 27, Our Product Offering January 27, 2014 Our Product Offering Toshiba LED lamps the advantages! Our lineup includes an extensive assortment of ENERGY STAR certified lamps in traditional / familiar shapes Exceptional light quality

More information

BELL. RACO, TayMac and BELL offer a full line of electrical products that are ideally suited to help you complete your next solar project

BELL. RACO, TayMac and BELL offer a full line of electrical products that are ideally suited to help you complete your next solar project SOLAR RACO, TayMac and BELL offer a full line of electrical products that are ideally suited to help you complete your next solar project Commercial, Industrial and Residential Electrical Products RACO

More information

Atlantic LED Exit and Emergency Light AI EECXERB1

Atlantic LED Exit and Emergency Light AI EECXERB1 tlantic LE Exit and Emergency Light I EECXER1 Illumination: Twin djustable Light Heads LEs Have 25+ Year Life Electrical: utomatic Low Voltage isconnect Fully utomatic Operation Push to Test Switch 120-277V

More information

10W Vapor Proof LED Fixture V AC - Replacement for 100W Incandescent - IP65

10W Vapor Proof LED Fixture V AC - Replacement for 100W Incandescent - IP65 10W Vapor Proof LED Fixture - 100-277V AC - Replacement for 100W Incandescent - IP65 Part #: VPL-MJ-10W-LED-WCM Page: 1 The VPL-MJ-10W-LED-WCM Vapor Proof LED Fixture from Larson Electronics is designed

More information

Page 1 T O O L S A N D M AT E R I A L S R E Q U I R E D. 1. Screwdriver 2. Carpenter's level 3. Electrical Tape PA R T S L I S T. A.

Page 1 T O O L S A N D M AT E R I A L S R E Q U I R E D. 1. Screwdriver 2. Carpenter's level 3. Electrical Tape PA R T S L I S T. A. T O O L S A N D M AT E R I A L S R E Q U I R E D 1. Screwdriver 2. Carpenter's level 3. Electrical Tape PA R T S L I S T A. Cabinet B. Wood Screw X4 C. Plastic wire connector x3 Page 1 I M P O R TA N T

More information

4.2 - PUMP MAINTENANCE MODELS: AC, AS, WC, WS

4.2 - PUMP MAINTENANCE MODELS: AC, AS, WC, WS 4.2 - PUMP MAINTENANCE MODELS: AC, AS, WC, WS 4.2.1 - EXPLODED VIEW DRAWING REF NO. 1 2 4 QTY 3 1 1.5 5 ¾ HP HP HP HP HP DESCRIPTION PART # 1 CASE 1.25 x 1 NPT 018266 1 CASE 1.25 X 1 NPT 018268 1 CASE

More information

REGATTA PATH LIGHT (RGP)

REGATTA PATH LIGHT (RGP) NEEDED FOR INSTALLATION: 5/64 & 5/32 Allen Wrench Waterproof Wire Connectors Warning Low Voltage Hot Surface Wear Gloves By Others Gloves IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION

More information

Commercial/Retail Lighting

Commercial/Retail Lighting Commercial/Retail Lighting Decorative luminaires for commercial and retail applications Exeter Series Simcoe Series 2 Juno Lighting Group Commercial/Retail Lighting Commercial and Retail Lighting Retail

More information

Echotel Model 910 Ultrasonic Level Switch

Echotel Model 910 Ultrasonic Level Switch Echotel Model 910 Ultrasonic Level Switch D E S C R I P T I O N Echotel Model 910 Level Switches utilize ultrasonic contact technology for measuring level in clean liquid applications. The dual conduit

More information

Custom Pendant- Hardwire Assembly and Installation Instructions

Custom Pendant- Hardwire Assembly and Installation Instructions Custom Pendant- Hardwire Assembly and Installation Instructions CAUTION: BEFORE INSTALLING FIXTURE, MAKE SURE THE POWER TO THE CIRCUIT IS TURNED OFF AT THE MAIN FUSE BOX / CIRCUIT BREAKER UTILITY BOX.

More information

5570M Series Intercom Installation and Operation Guide

5570M Series Intercom Installation and Operation Guide 5570M Series Intercom Installation and Operation Guide Isolated balanced/unbalanced lines Audio signals for the 5570M are transmitted over a wire pair using balanced line technology. An isolation transformer,

More information

I-VICFLEX.VS1. Victaulic VicFlex Style VS1 Dry Sprinkler WARNING WARNING TECHNICAL DATA BEND CHARACTERISTICS INSTALLATION INSTRUCTIONS SIDEWALL

I-VICFLEX.VS1. Victaulic VicFlex Style VS1 Dry Sprinkler WARNING WARNING TECHNICAL DATA BEND CHARACTERISTICS INSTALLATION INSTRUCTIONS SIDEWALL INSTALLATION INSTRUCTIONS I-VICFLEX.VS1 Victaulic VicFlex Style VS1 Dry Sprinkler SIDEWALL Y Read and understand all instructions before attempting to install any Victaulic VicFlex Style VS1 Dry Sprinklers.

More information