Buffer Tanks. Hydronic Accessories
|
|
- Lauren Wiggins
- 5 years ago
- Views:
Transcription
1 Hydronic Accessories Buffer s Our line of Chilled Water and Hot water Buffer tanks deliver all the quality and performance you expect from Taco products. They are built to last, shell, heads and ANSI flanges with ASME stamp. Constructed for 125 & 150 psi working pressures all while providing outstanding performance in the field, up to a standard operating temperature of 375 F. These products are available in standard connection sizes from 2 through 12 to meet the needs of a broad range of applications with custom unit sizes available. Our tank volumes range from 50 gallons up to 3000 gallons with 22 sizes, 2 arrangements, 3 connection types, 7 pipe sizes, 3 design temperatures, 2 design pressures and 14 insulation option as standard and custom sizes to meet our customers requirements. Taco Catalog # Supersedes: 08/04/14 Effective Date: 10/13/15 Printed in USA
2 Specifications -2- Many applications arise where a boiler or chiller may operate in a short cycle condition. Short cycling of the boiler or chiller is not recommended due to the high possibility of damage and or shortened component life, Short cycling is frequently due to the lack of Btu load balance between the demand of the hydronic system and the chiller or boiler Btu capacity. A buffer tanks is often utilized to introduce additional system fluid volume into the hydronic system to reduce the likelihood of this short cycling. A properly sized buffer tank optimizes the operation of the chiller or boiler and often introduces Btu storage allowing the system to operate without cycling the chiller or boiler. Buffer tanks are available in vertical or horizontal orientations with a wide range of diameters and lengths (available storage volumes.) Taco Inc. is pleased to offer a sizing app to aid in the sizing of buffer tanks. This app may be located at BTH BTL ANSI Data Table Class 150 RF30 SIZE O.D. B.C. #HOLES HOLE DIA. CL-CL /4 4 3/ / / /2 8 3/ /2 8 7/ /2 11-3/4 8 7/ / SPECIFICATIONS Designed and constructed per ASME Code Section VIII, Division 1. Construction: Carbon Steel with Exterior Red Oxide Primer Finish on ALL tanks Standard Design Pressure and Temperature: F d inlet and outlet System Connections (standard sizes shown) Registered with the National Board of Pressure Vessel Manufacturers Solid Internal Baffle Base Ring or Saddle Raised Nameplate OPTIONS (Consult Factory) Optional materials of construction Higher design pressures and temperatures Optional System Connection sizes available THERMAL INSULATION OPTIONS Chilled Water For Interior use 1/2 Armaflex _ C 3/4 Armaflex _ E 1 Armaflex _ D 1-1/2 Armaflex _ F 2 Armaflex _ G Chilled Water For Exterior use 1/2 Armaflex with nom. Aluminum Jacket_K 3/4 Armaflex with nom. Aluminum Jacket_ L 1 Armaflex with nom. Aluminum Jacket_ M 1-1/2 Armaflex with nom. Aluminum Jacket_ P 2 Armaflex with nom. Aluminum Jacket_ R Hot Water 1 Sillicone / Fiberglass_ H 2 Sillicone / Fiberglass_ J Chilled Water & Hot Water Appications 2 Polyiso Foam with nom. Aluminum Jacket_ S 3 Polyiso Foam with nom. Aluminum Jacket_ T d Grooved Threaded (up to 3 ) Saddles Base Ring Legs Chilled Water Insulation INSULATION OPTIONS FOR ALL TACO BUFFER TANKS Chilled/Hot Water with Aluminum Jacket Insulation Access the convenient Buffer s Wizard by going to Optional Anchor Clips Available Hot Water Insulation
3 -3- Quick Reference Guide Gallons Actual Gallons A B C D E F G Head Base Base to Ring Ring AFF () (in) Nozzle Size Maximum Approx. Dry Wt. Maximum Flooded Wt. BT_0050F -125N / /4 2, 3, BT_0075F -125N / /4 2, 3, BT_0100F -125N / /4 2, 3, , BT_0125F -125N / /4 2, 3, , BT_0150F -125N / , 3, , BT_0180F -125N / , 3, , BT_0200F -125N / , 3, , BT_0250F -125N / /8 3, 4, , BT_0300F -125N / /8 3, 4, , BT_0350F -125N / /8 3, 4, , BT_0400F -125N / /8 4, 6, , BT_0450F -125N / /8 4, 6, , BT_0500F -125N / /8 4, 6, , BT_0700F -125N / /8 4, 6, , BT_0850F -125N / /8 4, 6, , BT_1050F -125N 1,050 1, * 24-3/ /4 6, 8, , BT_1250F -125N 1,250 1, /72* 25-3/ , 8,10, , BT_1500F -125N 1,500 1, /72* 25-3/ , 8,10, , BT_1750F -125N 1,750 1, /84* 28-1/ /8 6, 8,10, , BT_2000F -125N 2,000 2, /84* 28-1/ /8 6, 8,10, , BT_2500F -125N 2,500 2, /96* /8 6, 8,10, , BT_3000F -125N 3,000 3, /96* /8 6, 8,10, , Surface Area (Sq. Ft.) BT_, H for High Connections, L for Low Connections F, Connection Size Required, Example: F06 TOP VIEW INTERNAL BAFFLE NOTCHED BELOW VENT 2 LIFTING LUGS (30" DIA. OR GREATER) FOR LIFTING EMPTY VESSELS ONLY D 2 NPT VENT G FLANGED SYSTEM CONNECTIONS CL. 150 ANSI RFSO (2 REQUIRED) A C B 5" COVERED INSPECTION OPENING (48" DIA. OR GREATER) RAISED NAMEPLATE BAFFLE B INSULATION OPTIONS G FLANGED SYSTEM CONNECTIONS CL. 150 ANSI RFSO (2 REQUIRED) D BASE RING BASE RING F E BTH 2" NPT DRAIN F E BTL 2" NPT DRAIN Go to > Products > Buffer s > Submittals
4 Quick Reference Guide Submittal Data BHL d Horizontal Buffer s with Low Connections -4- Volume A B** C D E F G H AFF to Saddle Data Nozzle Size BHL0050F -125N / , 3, BHL0075F -125N / , 3, BHL0100F -125N / , 3, BHL0125F -125N / , 3, BHL0150F -125N / , 3, BHL0180F -125N / , 3, BHL0200F -125N / , 3, BHL0250F -125N / , 4, BHL0300F -125N / , 4, BHL0350F -125N / , 4, BHL0400F -125N /4 18-1/ , 6, BHL0450F -125N /4 18-1/ , 6, BHL0500F -125N /4 18-1/ , 6, BHL0700F -125N /4 18-1/ , 6, BHL0850F -125N /2 19-3/ , 6, BHL1050F -125N ** 50-1/8 21-1/ , 8, BHL1250F -125N /8 ** / , 8, 10, BHL1500F -125N /8 ** / , 8, 10, BHL1750F -125N /4 ** / , 8, 10, BHL2000F -125N /4 ** / , 8, 10, BHL2500F -125N /2 ** / , 8, 10, BHL3000F -125N /2 ** / , 8, 10, **Add 2 to B dimension when specifying 10 or 12 nozzles. BHL Go to > Products > Buffer s > Submittals
5 -5- Submittal Data BHH d Horizontal Buffer s with High Connections Quick Reference Guide Volume A B** C D E F G H AFF to Saddle Data Nozzle Size BHH0050F -125N / , 3, BHH0075F -125N / , 3, BHH0100F -125N / , 3, BHH0125F -125N / , 3, BHH0150F -125N / , 3, BHH0180F -125N / , 3, BHH0200F -125N / , 3, BHH0250F -125N / , 4, BHH0300F -125N / , 4, BHH0350F -125N / , 4, BHH0400F -125N /4 42-1/ , 6, BHH0450F -125N /4 42-1/ , 6, BHH0500F -125N /4 42-1/ , 6, BHH0700F -125N /4 42-1/ , 6, BHH0850F -125N /2 46-3/ , 6, BHH1050F -125N ** 50-1/8 51-1/ , 8, BHH1250F -125N /8 ** / , 8, 10, BHH1500F -125N /8 ** / , 8, 10, BHH1750F -125N /4 ** / , 8, 10, BHH2000F -125N /4 ** / , 8, 10, BHH2500F -125N /2 ** / , 8, 10, BHH3000F -125N /2 ** / , 8, 10, **Add 2 to B dimension when specifying 10 or 12 nozzles. H* BHH Go to > Products > Buffer s > Submittals
6 Quick Reference Guide Submittal Data BHT d Horizontal Buffer s with Top Connections -6- Volume A B C D** E F G H AFF to Saddle Data Nozzle Size BHT0050F -125N / , 3, BHT0075F -125N / , 3, BHT0100F -125N / , 3, BHT0125F -125N / , 3, BHT0150F -125N / , 3, BHT0180F -125N / , 3, BHT0200F -125N / , 3, BHT0250F -125N / , 4, BHT0300F -125N / , 4, BHT0350F -125N / , 4, BHT0400F -125N /4 42-1/ , 6, BHT0450F -125N /4 42-1/ , 6, BHT0500F -125N /4 42-1/ , 6, BHT0700F -125N /4 42-1/ , 6, BHT0850F -125N /2 46-3/ , 6, BHT1050F -125N /8 51-1/ , 8, BHT1250F -125N / / , 8, 10, BHT1500F -125N / / , 8, 10, BHT1750F -125N / / , 8, 10, BHT2000F -125N / / , 8, 10, BHT2500F -125N / / , 8, 10, BHT3000F -125N / / , 8, 10, **Add 1 to D dimension when specifying 10 or 12 nozzles. B BHT Go to > Products > Buffer s > Submittals
7 -7- Submittal Data BHS d Horizontal Buffer s with Side Connections Quick Reference Guide Vol. A B C D** E F G H J K AFF to Saddle Data Nozzle Size BHS0050F -125N / , 3, BHS0075F -125N / , 3, BHS0100F -125N / , 3, BHS0125F -125N / , 3, BHS0150F -125N / , 3, /4 510 BHS0180F -125N / , 3, /4 590 BHS0200F -125N / , 3, /4 630 BHS0250F -125N / , 4, /4 710 BHS0300F -125N / , 4, /4 820 BHS0350F -125N / , 4, /4 910 BHS0400F -125N /4 42-1/ , 6, / BHS0450F -125N /4 42-1/ , 6, / BHS0500F -125N /4 42-1/ , 6, / BHS0700F -125N /4 42-1/ , 6, / BHS0850F -125N /2 46-3/ , 6, / BHS1050F -125N /8 51-1/ , 8, / BHS1250F -125N / / , 8, 10, 12 65** 36-1/ BHS1500F -125N / / , 8, 10, 12 65** 36-1/ BHS1750F -125N / / , 8, 10, 12 77** 42-1/ BHS2000F -125N / / , 8, 10, 12 77** 42-1/ BHS2500F -125N / / , 8, 10, 12 89** 48-1/ BHS3000F -125N / / , 8, 10, 12 89** 48-1/ **Add 1 to J dimension when specifying 10 or 12 nozzles. K BHS Go to > Products > Buffer s > Submittals
8 Quick Reference Guide Submittal Data BHL Grooved Horizontal Buffer s with Low Connections -8- Volume A B** C D E F G H AFF to Saddle Data Nozzle Size BHL0050F -125N / , 3, BHL0075F -125N / , 3, BHL0100F -125N / , 3, BHL0125F -125N / , 3, BHL0150F -125N / , 3, BHL0180F -125N / , 3, BHL0200F -125N / , 3, BHL0250F -125N / , 4, BHL0300F -125N / , 4, BHL0350F -125N / , 4, BHL0400F -125N /4 42-1/ , 6, BHL0450F -125N /4 42-1/ , 6, BHL0500F -125N /4 42-1/ , 6, BHL0700F -125N /4 42-1/ , 6, BHL0850F -125N /2 46-3/ , 6, BHL1050F -125N ** 50-1/8 51-1/ , 8, BHL1250F -125N / / , 8, 10, BHL1500F -125N / / , 8, 10, BHL1750F -125N / / , 8, 10, BHL2000F -125N / / , 8, 10, BHL2500F -125N / / , 8, 10, BHL3000F -125N / / , 8, 10, **Add 2 to B dimension when specifying 10 or 12 nozzles. mplete l Number wn below: 0G02-125N BHL Grooved Connections Go to > Products > Buffer s > Submittals
9 -9- Submittal Data BHH Grooved Horizontal Buffer s with High Connections Quick Reference Guide Volume A B** C D E F G H AFF to Saddle Data Nozzle Size BHH0050F -125N / , 3, BHH0075F -125N / , 3, BHH0100F -125N / , 3, BHH0125F -125N / , 3, BHH0150F -125N / , 3, BHH0180F -125N / , 3, BHH0200F -125N / , 3, BHH0250F -125N / , 4, BHH0300F -125N / , 4, BHH0350F -125N / , 4, BHH0400F -125N /4 42-1/ , 6, BHH0450F -125N /4 42-1/ , 6, BHH0500F -125N /4 42-1/ , 6, BHH0700F -125N /4 42-1/ , 6, BHH0850F -125N /2 46-3/ , 6, BHH1050F -125N ** 50-1/8 51-1/ , 8, BHH1250F -125N / / , 8, 10, BHH1500F -125N / / , 8, 10, BHH1750F -125N / / , 8, 10, BHH2000F -125N / / , 8, 10, BHL2500F -125N / / , 8, 10, BHL3000F -125N / / , 8, 10, **Add 2 to B dimension when specifying 10 or 12 nozzles. mplete l Number wn below: 0G02-125N BHH Grooved Connections Go to > Products > Buffer s > Submittals
10 Quick Reference Guide Submittal Data BHT Grooved Horizontal Buffer s with Top Connections -10- Volume A B C D** E F G H AFF to Saddle Data Nozzle Size BHT0050F -125N / , 3, BHT0075F -125N / , 3, BHT0100F -125N / , 3, BHT0125F -125N / , 3, BHT0150F -125N / , 3, BHT180F -125N / , 3, BHT0200F -125N / , 3, BHT0250F -125N / , 4, BHT0300F -125N / , 4, BHT0350F -125N / , 4, BHT0400F -125N /4 59 1/ , 6, BHT0450F -125N /4 59 1/ , 6, BHT0500F -125N /4 59 1/ , 6, BHT0700F -125N /4 59 1/ , 6, BHT0850F -125N /2 65 1/ , 6, BHT1050F -125N /8 71 1/4 ** , 8, BHT1250F -125N / /4 ** , 8, 10, BHT1500F -125N / /4 ** , 8, 10, BHT1750F -125N / /4 ** , 8, 10, BHT2000F -125N / /4 ** , 8, 10, BHT2500F -125N / /4 ** , 8, 10, BHT3000F -125N / /4 ** , 8, 10, **Add 1 to D dimension when specifying 10 or 12 nozzles. BHT Grooved Connections Go to > Products > Buffer s > Submittals
11 -11- Submittal Data BHS Grooved Horizontal Buffer s with Side Connections Quick Reference Guide Vol. A B C D E F G H J** K AFF to Saddle Data Nozzle Size / , 3, BHS0050G -125N / , 3, BHS0075F -125N / , 3, BHS0100G -125N / , 3, BHS0125F -125N / , 3, /4 510 BHS0150G -125N / , 3, /4 590 BHS0180G -125N / , 3, /4 630 BHS0200G -125N / , 4, /4 710 BHS0250G -125N / , 4, /4 820 BHS0300G -125N / , 4, /4 910 BHS0350G -125N /4 61 1/ , 6, / BHS0400G -125N /4 61 1/ , 6, / BHS0450G -125N /4 61 1/ , 6, / BHS0500G -125N /4 61 1/ , 6, / BHS0700G -125N /2 67 1/ , 6, / BHS0850G -125N /8 73 1/ , 8, / BHS1050G -125N / / , 8, 10, 12 65** 36-1/ BHS1250G -125N / / , 8, 10, 12 65** 36-1/ BHS1500G -125N / / , 8, 10, 12 77** 42-1/ BHS1750G -125N / / , 8, 10, 12 77** 42-1/ BHS2000G -125N / / , 8, 10, 12 89** 48-1/ BHS2500G -125N / / , 8, 10, 12 89** 48-1/ **Add 1 to J dimension when specifying 10 or 12 nozzles. K BHS Grooved Connections Go to > Products > Buffer s > Submittals
12 Buffer Coding Matrix with Baffles Position 1, 2 3 4, 5, 6,7 8 9, , 13, Description Buffer s Connection Location Gallons Connection Type Nozzle Size Design Temp. F Design psi Insulation Part Number BT H 0050 F N 1, 2, 3 Buffer s Carbon Steel Construction BTH BTL BHL BHH BHT BHS CT Vertical Buffer, Base Ring High Connections Vertical Buffer, Base Ring High Connections Horizontal Buffer Low Connections Horizontal Buffer Low Connections Horizontal Buffer Low Connections Horizontal Buffer Low Connections Custom * 4, 5, 6,7 Capacity Gallons Gallons Gallons Gallons Gallons Gallons Gallons Gallons Gallons Gallons Gallons Gallons Gallons Gallons Gallons Gallons Gallons Gallons Gallons Gallons Gallons Gallons Gallons --- Custom Gal. Request* 8 Connection F d G Grooved T Threaded, FNPT up to 2-1/2 9 Custom Type Request* 9, 10 Nozzle Size 02 2 ANSI 03 3 ANSI 04 4 ANSI 06 6 ANSI 08 8 ANSI ANSI ANSI --- Custom Size Request* 11 Design Temp. F F, Standard, BT Series A 400 F B 450 F 9 Custom Temp Request* 12, 13, 14 Design Pressure 125 psi 150 psi 9 Custom Pressure Request* 15 Insulation Options N No Insulation required For Interior use. Hot Water Insulation. H 1 Silicon/Fiberglass J 2 Silicon/Fiberglass For Interior use. Chilled Water Insulation. C 1/2" Armaflex E 3/4" Armaflex D 1" Armaflex F 1-1/2" Armaflex G 2" Armaflex For Exterior Use. Chilled Water Insulation. K 1/2" Armaflex w/ Alum. Jacket L 3/4" Armaflex w/ Alum. Jacket M 1" Armaflex w/ Alum. Jacket P 1-1/2" Armaflex w/ Alum. Jacket R 2" Armaflex w/ Alum. Jacket For Interior/ Exterior Use. Hot Water/Chilled Water Insulation. S 2" Polyisocyanurate with Alum. Jacket T 3" Polyisocyanurate with Alum. Jacket 9 Custom Insulation Request* PLEASE NOTE: Any Custom Request a Part Number to this Matrix, Sketch & Description MUST BE Sent with the Request. Selection Software (APPS) Pump Selection: Buffer s: Taco Inc., 1160 Cranston Street, Cranston, RI / (401) / Fax (401) Taco (Canada) Ltd., 8450 Lawson Road, Unit #3, Milton, Ontario L9T 0J8 / (905) / Fax (905)
Submittal Packages Detailed with Items and Reviewers
Submittal Packages Detailed with Items and Reviewers Tenochca Upgrades Project # 1 San Diego State University 00 Campanile Drive San Diego, CA 918 Tel: 619-94-740 Fax: 0079-1116-0 Circulating Pump Author
More informationCompressors, Chillers & Condensers
MARINE CONDENSER ACME MHX MARINE CONDENSER ACME Type MHX condensers are manufactured with the latest technology marine condenser tubing to provide compact size and cost effective use. STANDARD DESIGNS
More informationSeries 80 In-Line Mounted Centrifugal Pumps
Bulletin B-G Bell & Gossett Series In-Line Mounted Centrifugal Pumps Applications Hydronic Heating & Cooling Systems Industrial Process General Service Pressure Boosting Advantages Close Coupled Space
More informationAF-4 Grooved Flange Adapter
SUBMITTAL INFORMATION PROJECT NAME: ENGINEER: CONTRACTOR: SPEC. SECTION: MEMBER FEATURES & ADVANTAGES Designed for connecting ANSI/AWWA C110/A21.10 and ASME/ANSI B16.1 Class 125/ flanged end components
More informationFORM A-1P MANUFACTURER'S DATA REPORT FOR PLATE HEAT EXCHANGERS As Required by the Provisions of the ASME Code Rules, Section VIII, Division 2
Page of FORM A-1P MANUFACTURER'S DATA REPORT FOR PLATE HEAT EXCHANGERS As Required by the Provisions of the ASME Code Rules, Section VIII, Division 2 1. Manufactured and certified by: 2. Manufactured for:
More informationWATERFLUX 3000 Quick Start
WATERFLUX 3000 Quick Start Electromagnetic flow sensor The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000
More informationExcavating, Backfilling, and Compaction for Utilities Piping (Plumbing).
SECTION 15047 - IDENTIFICATION PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Identification including necessary accessories indicated on Construction Documents and specified in this section or as required
More informationDOLPHIN SHELL & TUBE MARINE CONDENSERS (DSTMC)
PIOEER I HEAT TRASFER TECHOLOGY DOLPHI SHELL & TUBE MARIE CODESERS (DSTMC) Dolphin Shell & Tube Marine Condenser (DSTMC) General Information Dolphin carries out Thermal Design, Mechanical Design & detailed
More informationAssmann Corporation of America TANK INSTALLATION AND USE GUIDELINES FOR BULK STORAGE TANKS
Assmann Corporation of America TANK INSTALLATION AND USE GUIDELINES FOR BULK STORAGE TANKS General Information Assmann polyethylene storage tanks are manufactured to give you the toughest, most reliable
More informationWe Are the Worldwide Provider for All Your Valve and Fitting Needs
Product Catalog We Are the Worldwide Provider for All Your and Fitting Needs C&C strives to earn your business by offering an extensive line of high quality products with a proven track record for successful
More informationPURESTREAM SYSTEM - ASSEMBLY GUIDE
PURESTREAM SYSTEM - ASSEMBLY GUIDE VISIT OUR WEBSITE : www.cagpurification.com our installment procedure videos in the PURESTREAM Piping section. NECESSARY TOOLS FOR INSTALLATION We suggest the use of
More informationHeat Exchanger Construction Checklist
Heat Exchanger Checklist Project: Pump tag: Building: Location: Submittal / Approvals Submittal. The above equipment and systems integral to them are complete and ready for functional testing. The checklist
More informationWATERFLUX 3000 Quick Start
WATERFLUX 3000 Quick Start Electromagnetic flowmeter The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000
More informationAMPreVA Pressure Vessels and Heat Exchangers
AMPreVA Pressure Vessels and Heat Exchangers Pressure Vessel Modeling & Configuration 3D Production Detailed Models Layout and Fabrication Drawings Production List and Bill of Material Fabrication Operation
More informationDEUTSCH Instructional Manual for HDP-400 Power Crimper (TE CONNECTIVITY PN )
ORIGINAL INSTRUCTIONS DEUTSCH Instructional Manual for HDP-400 Power Crimper (TE CONNECTIVITY PN 1606312-1) Instruction Sheet 0425-034-0000 15 JAN 18 Rev H NOTE All numerical values are in metric units
More informationSECTION IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT
SECTION 220553 - IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT Henderson Engineers, Inc. PART 1 - GENERAL REQUIREMENTS 1.1 SUMMARY A. Extent of Plumbing work to be identified as required by this Section
More informationProduct Guide Specification
Zurn Industries, LLC November 2014 1801 Pittsburgh Avenue Erie, PA 16502 Toll Free (855) 663-9876 Phone (814) 455-0921 Fax (814) 871-6141 Website www.zurn.com Product Guide Specification Specifier Notes:
More informationSection COUPLINGS AND COUPLING ADAPTERS. This Section covers couplings and coupling adapters for ductile iron and steel pipe.
PART 1 GENERAL 1.01 SUMMARY Section 15155 This Section covers couplings and coupling adapters for ductile iron and steel pipe. 1.02 MEASUREMENT AND PAYMENT A. No separate payment for Work performed under
More informationCalculations per ABS Code along with ASME Sec. VIII Div.1 XXXX
Calculations per ABS Code along with ASME Sec. VIII Div.1 XXXX Grouping of Boilers and Pressure Vessels: PART 4 CHAPTER 4 SECTOIN 1 Table #2 and #3 >> Group II PART 4 CHAPTER 4 SECTOIN 1 Appendix 1 Rules
More informationTable Of Contents Casing Head 02 Christmas Tree & Tubing Head Tubing Spool 04 Contact Us
Table Of Contents Casing Head 02 Christmas Tree & Tubing Head 03 Tubing Spool 04 Contact Us 05 1 www.sapwellsglobal.com Casing Head Specialized large-diameter pipe lowered into an open hole and cemented
More informationUNIFIED FACILITIES GUIDE SPECIFICATIONS
USACE / NAVFAC / AFCEC / NASA UFGS-43 41 16.16 40 (August 2017) --------------------------------- Preparing Activity: NASA Superseding UFGS-43 41 16.16 40 (August 2014) UFGS-43 41 16.16 (August 2010) UNIFIED
More informationFUEL GAS PIPING SECTION A. The provisions of SECTION 15010, MECHANICAL GENERAL REQUIREMENTS, apply to this section.
FUEL GAS PIPING SECTION 15355 PART 1 GENERAL 1.1 DESCRIPTION A. The provisions of SECTION 15010, MECHANICAL GENERAL REQUIREMENTS, apply to this section. B. This specification covers both interior and exterior
More informationSpecifications for EA31002 U Tube Bundle for CDU 3
Specifications for EA31002 U Tube Bundle for CDU 3 Tube Bundle Specificatio Tube Bundle for Heat Exchanger EA31002A/B/C/D Quantity required : One with Dummy shell Exchanger Type: BEU Horizontal No of U
More informationSECTION MECHANICAL IDENTIFICATION
PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions Specification Sections, apply to this Section. B. Related Sections:
More informationSight glass window Sight flow indicator
SIGHT GLASS Sight glass components allow operators to safely observe processes inside tanks, pipes, reactors and vessels. When it comes to selecting a sight glass, a wide variety of factors should be considered
More informationEchotel Model 911/921 Ultrasonic Level Switches
Echotel Model 911/921 Ultrasonic Level Switches D E S C R I P T I O N Echotel Model 911/921 ultrasonic level switches sense the presence or absence of liquids in a transducer gap by utilizing continuous
More informationA.O. SMITH WATER PRODUCTS COMPANY 5621 W. 115TH STREET ALSIP, ILLINOIS Phone: Fax:
PSD-3-158 GAS-FIRED COMMERCIAL REPLACEMENT PARTS LIST COPPER BOILERS FOR HYDRONIC HEATING & HOT WATER SUPPLY MODELS : 300, 400, 500, 650, 750 SERIES: 300, 301, 302, 303 2-STAGE UNITS A.O. SMITH WATER PRODUCTS
More informationI-W07/W77. Couplings DETAIL A WARNING. Photo Showing Pipe with Weld Seam Ground 6 inches/152 mm Back from Pipe End and an AGS Groove
WARNING Read and understand all instructions before attempting to install any Victaulic piping products. These products must be used only on pipe that is prepared to Victaulic Advanced Groove System (AGS)
More informationFisher 1052 Size 20 Diaphragm Rotary Actuator with H Mounting Adaptation
Instruction Manual 1052 Size 20 Actuator (H) Fisher 1052 Size 20 Diaphragm Rotary Actuator with H Mounting Adaptation Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications...
More informationSIGHT GLASS. Sight glass components allow operators to safely observe processes inside tanks, pipes, reactors and vessels.
SIGHT GLASS Sight glass components allow operators to safely observe processes inside tanks, pipes, reactors and vessels. SIGHT GLASS Sight flow indicator. A sight flow indicator is used in process pipelines
More informationUNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:
SECTION 230553 - IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 SUBMITTALS A.
More informationImportant Notices. Manway Lockout Point
2 Drawing CM-1B Important Notices 1. We palletize all manways to avoid damage during shipment and subsequent handling at the jobsite. We suggest that the manway remain on the pallet until installation.
More informationInstrumentationTools.com
Author: Instrumentation Tools Categories: Guest Articles Level Transmitter and Level Gauge Design Tips Level Transmitter and Level Gauge Design Tips Level / Vessel Sketches What is this? Level sketch or
More informationOPTIFLUX 1000 Technical Datasheet
OPTIFLUX 1000 Technical Datasheet Electromagnetic flow sensor in sandwich design Lightweight and compact Excellent price performance ratio Quick and easy to install The documentation is only complete when
More informationICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JÉRÔME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) FAX: (450) INSTALLATION AND OPERATION INSTRUCTIONS
ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JÉRÔME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) 565-6336 FAX: (450)565-6519 INSTALLATION AND OPERATION INSTRUCTIONS "IS" CHIMNEY TYPE: SIZE: FACTORY BUILT CHIMNEY FOR
More informationFord Water Meter Couplings & Accessories
Section H 2/2001 Ford Water Meter Couplings & Accessories The Ford Meter Box Co., Inc. 775 Manchester Avenue, P.O. Box 443, Wabash, Indiana, USA 46992-0443 Telephone: 260/563-3171 FAX: 1-800-826-3487 Overseas
More informationNUS-4. Ultrasonic Level Transmitter. for Liquids and Solids
Ultrasonic Level Transmitter for Liquids and Solids measuring monitoring analyzing 4 Measuring Ranges: Liquids: Up to 25 meters (80 feet) Solids: Up to 10 meters (32 feet) Accuracy: ± 0.2 % of Reading
More informationICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JEROME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) FAX: (450)
ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JEROME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) 565-6336 FAX: (450)565-6519 www.icc-rsf.com INSTALLATION AND OPERATION INSTRUCTIONS "Model VIP" CHIMNEY TYPE: FACTORY BUILT
More informationMagnetic level indicators made in Australia under licence to Weka AG of Switzerland.
ABN 24 080 175 293 PO Box 212 Caringbah NSW 1495 Sydney Australia ph: +61 (0)2 9542 8977 fx: +61 (0)2 9542 7978 www.controlcomponents.com.au Magnetic level indicators made in Australia under licence to
More informationCS3 represents manufacturers of products for use in the municipal waterworks industry.
Brian Drexel & Rob Grier WWW.CS3WATERWORKS.COM Established in 2000, CS3 Waterworks is a Florida Based company with offices in Orange Springs Florida and Savannah Georgia. CS3 represents manufacturers of
More informationSECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING
SECTION 230516 - EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and
More informationMT-VESS MECHANICAL CALCULATION OF PRESSURE VESSELS
MT-VESS MECHANICAL CALCULATION OF PRESSURE VESSELS The software program MT-VESS allows the mechanical design and stability check of pressure vessels. The rating of existing pressure vessels is also allowed.
More informationChapter VI Vessel Supports
Chapter VI Vessel Supports 1 2 Vessel Supports Vessel support is to a. Support the weight of the container b. Fix the container position c. Keep the container in operation. Classified by the type of vessels:
More informationLevel Measurement Continuous level measurement Radar transmitters
Overview Configuration Mounting on a nozzle is a 2-wire 25 GHz pulse radar level transmitter for continuous monitoring of solids and liquids in storage vessels including extreme levels of dust and high
More informationDrilling & Tapping Wide selection from a single source. Durable designs.
Drilling & Tapping Wide selection from a single source. Durable designs. Type No. of Models Nom. Size (in.) Page Hole Cutting Model HC300 3 Up to 3" 6.2 Model HC450 3 Up to 4 3 4" 6.3 Hole Saws 51 Up to
More informationWater Circulation Pumps & Circulators PERFORMANCE CURVES. CI Pumps. FI Pumps. Taco Curve Book B
Water Circulation Pumps & Circulators PERFORMANCE CURVES FI Pumps CI Pumps Taco Curve Book 300-2.5B Effective April 27, 2017 (Supersedes March 31, 2012 CAPACITY IN LITERS/SEC FLOW IN GALLONS PER MINUTE
More informationCONDENSATE DRAIN PANS
CONDENSATE DRAIN PANS TOTALINE CONDENSATE DRAIN PANS Totaline Condensate Drain Pans prevent harmful overflow moisture from reaching ceiling tiles, insulation or living space. Especially used in the attic
More informationWE CREATE IMPOSSIBLE ABOUT US. KASRAVAND is a DESIGN and MANUFACTURING Company
FIXED EQUIPMENT ABOUT US KASRAVAND is a DESIGN and MANUFACTURING Company with high Engineering and Management competency. We design & manufacture PROCESS PACKAGES such as FLARE GAS RECOVERY,TEG,MEG,WATER
More informationAllentown, PA - Plant Expansion Steel Pipe Spec. No. 671-S40 December 31, 2015
Steel DIVISION 15: MECHANICAL SECTION 15061: STEEL PIPE 1.0 GENERAL All materials shall be of high quality and as per the following specifications. 2.0 PRODUCTS 2.1 Specification CS-1 Service = (CA, VAC)
More informationEssex County College - West Essex Campus Addition And Renovations dlb # / SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING
SECTION 230516 - EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING PART I - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and
More informationMechanical Support Systems, Inc.
Mechanical Support Systems, Inc. CATALOG February, 2014 www.thesmartsupports.com 408.601.0155 1 N E W W E B S I T E.N E W P R O D U C T S Mechanical Support Systems, Inc. is certified as a women s business
More informationStepping ahead in technology & innovation PIPING INSTITUTE OF TECHNOLOGY & ANALYSIS SOLUTIONS
Stepping ahead in technology & innovation PIPING INSTITUTE OF TECHNOLOGY & ANALYSIS SOLUTIONS PIPING ENGINEERING & PLANT DESIGN Chapter 1. Introduction of Piping Industry & Role of Piping Engineer 1.1.
More informationUniversity of Houston Master Construction Specifications Insert Project Name SECTION MECHANICAL SCOPE OF WORK PART 1 - GENERAL
SECTION 23 00 10 - MECHANICAL SCOPE OF WORK PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section 23 01
More information3 Emergency Breakaway Coupling
SM64227 July 2008 Applicable addition manuals: N/A Aerospace Group Conveyance Systems Division Carter Ground Fueling Maintenance & Repair Manual 3 Emergency Breakaway Coupling Model 64227 Table of Contents
More informationTELEPHONE: (215) Addendum No Cooling Plant Replacement SDP Contracts No. B-080C, B-081C and B-082 of 2017/18
THE SCHOOL DISTRICT OF PHILADELPHIA SCHOOL REFORM COMMISSION Office of Capital Programs 440 North Broad Street, 3 rd Floor Suite 371 Philadelphia, PA 19130 TELEPHONE: (215) 400-4730 Addendum No. 001 Subject:
More informationGeneral Information...SA1-SA4
SECTION S INDEX Product Description Page Number General Information................................................................SA1-SA4 Type FSK Thruwall & Floor Seal For Conduit, Pipe or Tubing............................
More informationSPECIALTY SMART N CLEVER PRODUCTS
REVERSIBLE DRUM ANGEL 316L STAINLESS STEEL REVERSIBLE DRUM ANGEL Empty or fill a 55-US gallon drum (45 Imperial/205L) in under 90 seconds! Reversible unit fills and empties a drum SMART N CLEVER MORE THAN
More informationREPAIR CLAMP PARTS H fax: MULTIPLIER
REPAIR CLAMP PARTS Part Number Component Description Model Number Product Size List Price Unit V001 Neoprene Sheet Gasket AS All Sizes Square Inch V002 Waffle Pattern Gasket (NBR) AS All Sizes Square Inch
More informationA representative from Occupational Health is to be involved in the commissioning process to address any Respiratory Protection Program requirements.
SPEC-3017 1/8 1.0 PURPOSE This specification describes the minimum requirements for the installation of breathing air distribution systems (indoor and outdoor) up to the connection to the breathing air
More informationHose Accessories. "Air King" 4 - Lug Quick-Acting Couplings. Hose End. Female N.P.T. End
"Air King" 4 - Lug Quick-Acting 1¼" 1½" AM16 AM AM6 AB16~ AB~ AB6 End Rubber Washers for 4-Lug AWR14 Fits all sizes 1¼" 1½" AM18 AM3 AM8 AB18~ AB3 AB8 Rated to 1 PSI Female N.P.T. End "Boss" clamps recommended
More informationFAIRBANKS NIJHUIS 1590 SERIES SINGLE STAGE VERTICAL INLINE PUMP.
FAIRBANKS NIJHUIS 0 SERIES SINGLE STAGE VERTICAL INLINE PUMP www.fairbanksnijhuis.com FAIRBANKS NIJHUIS 0 Series Single Stage Vertical Inline Pump Capacities to 00 GPM (,00 m/hr) Heads to 0 Feet ( m) Temperatures
More informationEchotel Model 910 Ultrasonic Level Switch
Echotel Model 910 Ultrasonic Level Switch D E S C R I P T I O N Echotel Model 910 Level Switches utilize ultrasonic contact technology for measuring level in clean liquid applications. The dual conduit
More informationLengths [7] Ø.50 [13] [7] [13]
Dimensions in [ ] are in millimeters Standard (2 1 / 2 6 ) Standard (9 24 ).75 STEM.40 [10] EXTERNAL THREAD.61 [15] 1.00 [25] STEM STEM Ø.44 [11] Threaded-Stepped Shank Standard Stem Length Length (T)
More informationGENERAL ISOMETRIC LAYOUT
EXISTING OR PROPOSED WIPER WALL SUPPORT STRUCTURE GATE LID CARBATHAN HG 0 WEB GRAY LOWER PAN GRATING ALUMINUM WIPER WALL CARBATHANE HG, 90 GRAY STRUCTURAL SPECIFICATIONS:. FLOODGATE MATERIAL TO BE ALUMINUM
More informationGuided Wave Radar Bulk Solids Level Transmitter
www.ktekcorp.com Guided Wave Radar Bulk Solids Level Transmitter FEATURES Radar Signal Travels Along the Waveguide Eliminates False Echoes and Minimizes Signal Loss No Moving Parts 2 Wire Loop Powered
More informationB. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.
SECTION 081113 - HOLLOW METAL DOORS AND FRAMES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Standard hollow metal doors and frames. 1.2 SUBMITTALS A. Product Data: For each type of product indicated.
More informationSECTION MECHANICAL IDENTIFICATION
Buebtel/Perlcins Community Learning Center GPD - 2001271.15 SECTION 15075 MECHANICAL IDENTIFICATION PART 1- GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General
More informationEchotel Model 910 Ultrasonic Level Switch
Echotel Model 910 Ultrasonic Level Switch D E S C R I P T I O N Echotel Model 910 Level Switches utilize ultrasonic contact technology for measuring level in clean liquid applications. The dual conduit
More informationGeneral Spec Sheet: 18 x 24 (457mm x 610mm) Vent
General Spec Sheet: 18 x 24 (457mm x 610mm) Vent The 18 x 24 (457mm x 610mm) Vent is a functional and decorative vent designed to provide unforced free air flow ventilation of attics or similar spaces
More informationNCCER Progress Blvd, Alachua, Florida Phone: (888)
NCCER 13614 Progress Blvd, Alachua, Florida 32615 Phone: (888) 622-3720 E-mail: info@nccer.org PIPEFITTING Competencies / Objectives Level One MODULE 08101-06 - ORIENTATION TO THE TRADE 1. Describe the
More informationSeries 4310 A Partnership for Success Series Battioni P agani Battioni Pagani Series Pompe natv ac.c om
Vacuum Pumps & Blowers 4310 Blower A Partnership for Success Commercial duty Battioni Pagani Battioni Pagani Pompe Vacuum pumps & Blowers Vacuum / Pressure Pumps MEC 2000-4000 607 - National Vacuum Equipment
More informationTOGGLE CLAMPS. Holding Pressure Competitor Conversion Index General Information
Holding Pressure Competitor Conversion Index... 124 General Information... 124 Hold Down Action Vertical Handle... 125-129 Horizontal Handle... 130-132 Toggle Pliers... 133-134 Straight Line Action...
More informationKerkau Manufacturing. B16.5 Flange Book
Kerkau Manufacturing B16.5 Flange Book TABLE OF CONTENTS Revision 1 Title Page Table of Contents Tolerance Page Permissible Imperfections Dimensions of Flange Facings (all pressure rating classes) Dimensions
More informationGuided Wave Radar Level and Interface Transmitter
www.ktekcorp.com Guided Wave Radar Level and Interface Transmitter FEATURES Total and Interface Level Measurement with One Transmitter Graphic Display with Waveform Screen All Digital Electronics Weak
More informationaurotherm VFK 990 solar collectors Affordable Solar Hot Water
aurotherm VFK 990 solar collectors Affordable Solar Hot Water 96 TRANSMISSION Works well in limited sunshine COPPER ABSORBER Provides excellent thermal conductivity WEIGHS ONLY 94 POUNDS Ensures easy on-roof
More informationAssembly Instructions for Key-Lock mechanical joints in sizes 2 to 40 inch ( mm)
Assembly Instructions for Key-Lock mechanical joints in sizes 2 to 40 inch (50-1000 mm) Introduction This guide provides recommendations for the installation of Bondstrand piping systems using the Key-Lock
More informationfor Andersen 400 Series Woodwright Transom over 400 Series Woodwright Double-Hung or 400 Series Woodwright Picture Window
for Andersen 400 Series Woodwright Transom over 400 Series Woodwright Double-Hung or 400 Series Woodwright Picture Window Congratulations! You have just purchased one of the many fine Andersen products.
More informationPrecision Thermistor Sensors
Precision Thermistor Sensors For Laboratory Applications ON-400 Series U For Use in Laboratory or Other High-Accuracy Applications U Rugged Construction Can Be Used for Short Term Water and Soil Readings
More informationStargrip series 3000 Mechanical Joint Wedge Action Restraint for Ductile Iron Pipe
Stargrip series 3000 Mechanical Joint Wedge Action Restraint for Ductile Iron Pipe INFORMATION The Stargrip Mechanical Joint Restraint System is a unique product with a proven design that provides an exceptional
More informationMODEL Service Manual. IMPORTANT: Fill in pertinent information on page 2 for future reference.
MODEL 9000 Service Manual IMPORTANT: Fill in pertinent information on page for future reference. Job Specification Sheet * JOB NO. * MODEL NO. * WATER TEST * CAPACITY PER UNIT MAX. PER REGENERATION * MINERAL
More informationFlange Dimensions Class 125 Bronze Flange Dimensions Class 300 Bronze Flange Dimensions Class 150 Bronze Flange Dimensions
Dimensions Class Bronze Dimensions Meets Ib. A.S.M.E. Stard Class 00 Bronze Dimensions Meets ANSI STD B. Nominal Dim. A O.D. Dim. B Circle Dim. C Hole No. Holes Nominal Dim. A Diam. Dim. B Min. Dim. C
More information6M HALO VERSON II + OPTIONAL 2M GROUND PLANE
The halo is an omnidirectional, horizontally polarized antenna with about the same gain as a dipole but without the low elevation nulls off the ends (+5.5 to +3.5dBi variation for the Halo vs. +7.9 to
More informationKotron Sentinel Models 822, 832 and 842 RF Point Level Switches
Kotron Sentinel Models 8, 8 and 84 RF Point Level Switches D E S C R I P T I O N The Sentinel is a powerful multi-point level switch. The microprocessor-based circuitry has non-volatile memory, to protect
More informationGB/GW GB/GW GB/GW GB/GW
GAS-FIRED COMMERCIAL REPLACEMENT PARTS LIST COPPER BOILERS FOR HYDRONIC HEATING & HOT WATER SUPPLY MODELS : 1000, 1300, 1500, 1850, 2100, 2500 SERIES: 400-405 A.O. SMITH WATER PRODUCTS COMPANY 500 TENNESSEE
More informationPipe Product Catalog Table of Contents
Pipe Product Catalog Table of Contents Section A: Drawing #: Page Description A1 Reinforced Concrete Pipe A3 Storm Manhole Sizing Chart (48" - 96") A3.1 Storm Manhole Sizing Chart (108" - 144") A4 48"
More informationLevel Measurement. Continuous level measurement Capacitance transmitters SITRANS LC300. icenta Controls Ltd
Overview onfiguration Installation uild up of material in active shield area does not affect switch operation. Mounting on a bypass is an inverse frequency shift capacitance continuous level transmitter
More informationTHE IMPORTANCE OF THE FITTING
JOHNSON RISER PIPES Geometrical characteristics (diameter, depth), pump pressure and water quality are the principal factors determining the choice of the riser pipe and the fitting type. These choices
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More informationSubmittal Data Sheet Wilo MVI - Vertical Multistage Pumps
Wilo MVI Project: Engineer: Contractor: Submitted By: Date: Approved By: Date: Tag # Model # Flow Head HP Cycle Phase Voltage RPM Hz H [ft] ηp [%] P [hp] 7 7.......7..9.......................... MVI -
More informationAnnexure - V. Specifications, Typical Drawing & Data Sheet for Split TEE (Hot Tapping Material)
Annexure - V Specifications, Typical Drawing & Data Sheet for Split TEE (Hot Tapping Material) CONTENTS SL NO. DESCRIPTION 1.0 SCOPE 2.0 REFERENCE DOCUMENTS 3.0 MANUFACTURER'S QUALIFICATION 4.0 MATERIALS
More informationSwivel Hoist Ring RIGGING ACCESSORIES. Color coded to distinguish between UNC (Red) and Metric (Silver) thread types.
RIGGING ACCESSORIES Color coded to distinguish between UNC (Red) and Metric (Silver) thread types. Available in UNC and Metric thread sizes. UNC threads available in sizes from 800 pounds to 100,000 pounds,
More informationFES SUBSEA HOT STAB. FES Subsea Merchant Court, Ashington, Northumberland, England, NE63 0YH
FES SUBSEA HOT STAB Flexible Engineered Solutions have built up a reputation for satisfying clients with a range of standard & bespoke ROV operable Hot Stab Connectors for use in fluid transfer systems
More informationWindows Installed into Walls with Polyiso and Wood Framing. Installation Instructions Standard Method Revised 10/24/2016
Windows Installed into Walls with Polyiso and Wood Framing Installation Instructions Standard Method Revised 10/24/2016 Background There are many acceptable ways to mount and detail windows for support
More informationA. Compatibility: Products shall be suitable for piping service fluids, materials, working pressures, and temperatures.
SECTION 22 05 16 LOOPS FOR PLUMBING PIPING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More information914DNS. Pressure and Density Transmitter. Features. 1 Datasheet 914DNS Pressure and density transmitter.
Pressure and Density Transmitter Features Pressure and density transmitter. Low maintenance, quick calibration and configuration. Installation directly into pressurized vessels. HART technology provides
More informationFisher 667 Diaphragm Actuators Size 80 and 100
Instruction Manual 667 Size 80 and 100 Actuators Fisher 667 Diaphragm Actuators Size 80 and 100 Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications... 2 Maximum Pressure Limitations...
More informationTechnologies, Solutions, and Applications. Level Switching
Technologies, Solutions, and Applications Level Switching Contents Leadership in Level Switching 3 How We Earn Your Business 4 Models & Versions 5 About Level Switching 11 Assurance with Redundant Systems
More informationReliance SG800 Series Steel Water Gage Valves
Installation, Operation, & Maintenance Instructions R500.541D1 10/16/2016 Reliance SG800 Series Steel Water Gage Valves Note: Design variations in Steel Water Gage Valves necessitate typical illustrations,
More informationPiping & Equipment Identification
Piping & Equipment Identification Part 1 General 1.01 Description of Work A. Work in this section includes: Identification materials, including necessary accessories indicated on Contract Documents and
More informationMulti-Set II Drop-In Anchors
CONCRETE ANCHORING SPECIALISTS Internally Threaded Heavy- Duty Anchoring Systems DESCRIPTION/SUGGESTED SPECIFICATIONS Drop-In, Shell-Type Anchors SPECIFIED FOR ANCHORAGE INTO CONCRETE Drop-In, shell-type
More information