MODEL: DLS. Telemetering System

Similar documents
MODEL: DAST-20. Telemetering System

MODEL: WL40MW1F. Wireless I/O WL40F Series

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

MODEL: R1C-GH. Remote I/O R1X Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: DA3. Plug-in Signal Conditioners M-UNIT

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

MODEL: R9CWTU. Remote I/O R9 Series. EXTENSION UNIT 1: With connection

JRQ2 ENCODER POSITION TRANSMITTER MODEL. Plug-in Signal Conditioners M-UNIT. (field-programmable; built-in excitation)

MODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value.

MODEL: KS. Plug-in Signal Conditioners K-UNIT

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

MODEL: MRP6D. POWER INPUT DC Power R: 24 V DC. Final Control Elements

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

MODEL: JB2. Plug-in Signal Conditioners M-UNIT

MODEL: MRP6. Final Control Elements

MODEL: M6SXT. POWER INPUT DC Power R: 24 V DC

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MODEL: R30US4. Remote I/O R30 Series

MODEL: JPR2. Plug-in Signal Conditioners M-UNIT

MODEL: RPPD. Plug-in Signal Conditioners M-UNIT. [2] INPUT 2 Must be the same code as the one chosen for Input 1.

MODEL: M2VF MODEL: M2VF [1][2] [3][4]

MODEL: VOS-ER. [4] LEVER POSITION 1: Upper side 2: Lower side. Position Sensors

96M0374. Instruction Manual. Analog Sensor Controller. RD Series

MODEL: TC10EM. Temperature Controller TC10 Series

MODEL: W2TS. Mini-MW Series

MODEL: RZMS-U9. PC Recorders RZMS Series

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

MODEL: M2DYS SEN TRONIC AG

MODEL: 20VS2-02. Hybrid IC Isolation Amplifiers 20 Series

General Specifications

MODEL: M2EXT. Super-mini Signal Conditioners with Display Mini-M M2E Series

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

NPN TRANSISTOR OUTPUT MODULE

MODEL: M1EXT. with Display M1E Series

MODEL: R3-RS8A. Remote I/O R3 Series. RTD INPUT MODULE (high accuracy, 8 points, isolated) MODEL: R3-RS8A[1][2]

Jacket heater, etc Mounting bracket for Pipe wrapping. (Optional) Temperature sensor. Output (To heater) (Optional)

MODEL: AS4V. Plug-in Signal Conditioners M-UNIT

MODEL: M3LU. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

Coaxial Switch. Ordering Information. High-frequency, High-capacity Coaxial Switch Supporting Bandwidth to 26.5 GHz. Model Number Legend:


Intermittent Vibration 0.075

JPQ2 PULSE ACCUMULATOR

Miniature Synchronous Multipoint Modems


CP485-4 User s Manual

CompoNet Gateway Unit for CC-Link

RS 485/422 to Fibre Optic Modems ELO E243, ELO E244, ELO E245. Operation manual

1995 Metric CSJ SPECIAL SPECIFICATION ITEM Drop/Insert Multiplexor/Demultiplexor

SPECIAL SPECIFICATION 1533 Drop/Insert Multiplexor/Demultiplexor

MODEL: M3LU2. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

XIOC technology and networking modules

General Specifications

Multi-point Temperature Controller

General Specifications

MODEL: R3-WT4B. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R3 Series

SHIMADEN DIGITAL INDICATORS

USER MANUAL MODEL Time Division Multiplexor, RS-232 (CTS TDM-V.24) SALES OFFICE (301) TECHNICAL SUPPORT (301)

Data Acquisition Modules/ Distributed IO Modules

SHIMADEN DIGITAL INDICATOR

MODEL: 47LV. Digital Panel Meters 47 Series

FA Wireless SS Terminals

General Specifications

Operation. Displayed channel. Measuring range. Status indication/ remote control Key lock Measuring mode/ time constant. Scale.

[3] MOUNTING DIRECTION

Absolute Rotary Encoder

MODEL: 27HU 27-UNIT MODEL: 27HU [1][2]

DISCRETE INPUT MODULE, 16 points

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

FOM-5A, 6A Asynchronous Fiber Optic Modems

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

USER MANUAL MODEL Parallel to Serial/ Serial to Parallel Interface Converter

Distance-setting Photoelectric Sensor

Cable connection. Sigma-II series SERVOPACK SGDH- 200V. Ver. Servo Drive CN3 (CN10) CN1 CN2 NS500 JUSP-NS500 SERVOPACK. 200V Ver.

MODEL: R3-WT4. Remote I/O R3 Series. [4] OPTIONS blank: none /Q: With options (specify the specification) AC POWER INPUT MODULE (4 input circuits)

SHIMADEN DIGITAL INDICATORS

General Specifications

Basic module X-TIO FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10 FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10. Communications (RS-485)

1995 Metric CSJ SPECIAL SPECIFICATION ITEM Add/Drop Multiplexor/Demultiplexor

INTRODUCTION. T hank you for your HB8215/HB8216 loadcell indicator purchase. The HB8215 and HB8216 are the best choice for industrial weighing

SR25. SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists MICROPROCESSOR-BASED AUOT-TUNING PID CONTROLLER

Solid State Broadband High Power Amplifier

General Specifications

6ES7314-6BH04-0AB0. STEP7 as of V5.5 + SP1 or STEP 7 V5.3 + SP2 or higher with HSP 204

Concept of Serial Communication

Cable connection. Sigma-II series SERVOPACK SGDH- 200V. Ver. Servo Drive CN3 (CN10) CN1 CN2 JUSP-NS500 NS500 SERVOPACK. 200V Ver.

JTY2 PULSE DURATION RECEIVER BEFORE USE... COMPONENT IDENTIFICATION

MV110-8AS. Analog input module 8 channel. User guide

PULSE INPUT MODULE PI232/PI272 USER S MANUAL

Fuzzy Temperature Controllers E5AF

Name Number of I/O points (words used) Model Antenna style. 512 outputs max. (32 words) Magnetic Base Antenna (1) --- WD30-AT001 (See note.

MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series

MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE

General Specifications

SPECIFICATIONS Digital Indicator 1. General

Interface: Serial EIA RS-232D/CCITT V.24, DCE; RTS/CTS delay 0,8 or 64 ms (user-selectable).

NETWORK. TE = Terminal Equipment (DTE - Data Terminal Equipment) NT = Network - Terminating Equipment (DCE - Data Circuit - Terminating Equipment)

INS500 Series Driver ( **CE Approved ) 5 Phase NanoDrive DC Type Driver Units

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MA-12 AC MA-12 DC. Korthållsmodem Short haul modem Kurzstreckenmodem

Transcription:

POW RUN SA SA RT RU MODEL: DLS Telemetering System TELEMETERING UNIT Functions & Features Interfacing remote I/O devices with a modem for a telemetering system Process I/O (.0) [] POWER INPUT AC Power K: V AC (Operational voltage range V, Hz) L: 0 V AC (Operational voltage range 0 V, Hz) DC Power S: V DC (Operational voltage range V ±0 %, ripple 0 %p-p max.) R: V DC (Operational voltage range V ±0 %, ripple 0 %p-p max.) Note: Modem /Ax not selectable for use with DC power input. FIBER LINK 00 (.) 00 (.) mm (inch) MODEL: DLS [][] [][] ORDERING INFORMATION Code number: DLS-[][]-[][] Specify a code from below for each [] through []. (e.g. DLS-SAB-K/MA) [] TRANSMISSION MEDIA : Twisted-pair cable : Fiber optics cable : Twisted-pair fiber optics (repeater incorporated) [] MODEM /AA: M-System's 0 bps use modem (model: MOD); Station A /AB: M-System's 0 bps use modem (model: MOD); Station B /MA: M-System's 00 bps use modem (model: MOD); Station A /MB: M-System's 00 bps use modem (model: MOD); Station B /MA: M-System's 00 bps use voice/data modem (model: MOD, MOD); Station A /MB: M-System's 00 bps use voice/data modem (model: MOD, MOD); Station B /MA: M-System's 00 bps use modem (model: MOD, MOD); Station A /MB: M-System's 00 bps use modem (model: MOD, MOD); Station B /MA: M-System's 00 bps use modem (model: MOD); Station A /MB: M-System's 00 bps use modem (model: MOD); Station B Note: Consult factory for modem specifications. [] I/O SECTION 00: None A: Di points A: Di points C: Do points (relay) C: Do points (open collector) C: Do points (relay) C: Do points (open collector) E: Di + Do points (relay) E : Di + Do points (open collector) Gx: Ai points Mx: Ao points Px : Pi + Ai points Rxx: Ai + Ao points Sxx: Ai + Ao + Di + Do points Ux : Po + Ao points See data sheet for Standard Multi-Transmission Unit (model: DLA) for specifications of I/O sections. RELATED PRODUCTS Standard multi-transmission unit (model: DLA) terminal block (model: CNT) RS cable (model: DCN) Special cable with 0-pin connector (model: FCN) 0 bps modem (model: MOD) 00 bps modem (model: MOD) Voice/data modem (model: MOD, MOD) 00 bps modem (model: MOD, MOD) 00 bps modem (model: MOD) GENERAL SPECIFICATIONS Construction: Surface mounting; terminal access on the front Connection Transmission line terminal: Euro type connector terminal; wire size. mm max. Power supply terminal: Euro type connector terminal; wire http://www.m-system.co.jp/ DLS SPECIFICATIONS ES- Rev. Page /0

size. mm max. RUN contact output: Euro type connector terminal; wire size. mm max. I/O section: -point I/O (or less): 0-pin connector terminal; M screws (torque 0. N m) -point I/O: FCN 0-pin connector (two); (FUJITSU FCN-P00-AU) Housing material: Flame-resistant resin (beige) Isolation: I/O to transmission section to power DIP switch: Setting RS--C specifications or modem settings (except "/A") Station No. adjustment: rotary switches; 00 FF () Controller & Transmission Sections Power indicator: Red LED turns ON in normal conditions; OFF when the voltage level becomes low. RUN indicator: Red LED turns OFF in error. I/O Section Contact I/O indicator LED: Red lights turn on when the respective I/O channels are ON. Analog I/O CPU RUN indicator LED: Red LED turns ON when the CPU function proves normal, OFF in error. RUN Contact Output: Contact opens in error. Rated load: 00 V AC or 0 V DC @ A (resistive load) Maximum switching voltage: 0 V AC or 0 V DC Maximum switching power: 00 VA or 0 W Minimum load: V DC @ 0 ma Error detection Communication: The receiver units detect loss of communication and wire break. CPU: Watch-dog timer Power voltage: Detects when the voltage supply to the CPU drops by 0 %. MULTIPLEX COMMUNICATION Communication: Half-duplex, synchronous Transmission: Conform to RS-, EIA Transmission speed: kbps Protocol: SIN-NET (M-System's; data format conforms to SDLC) Error check: CRC Twisted-pair Cable Cable: CPEV-0. dia. Connection: Euro Type connector terminal; wire size. mm max. Transmission Distance: kilometer max. with units connected; kilometers max. between stations each of which consists of units Terminator: Incorporated (Remove the attached jumper pin when the unit is not located at the end of transmission line.) Fiber Optics Cable Link: JIS F0 connector (Consult factory for details) Transmission distance: kilometer max. with PCF Transmission loss: db max. Twisted-pair Fiber Optics: Converting signals between two media and waveform shaping MODEM / INTERFACE Transmission: Conform to EIA RS--C Communication: Asynchronous, half-duplex, non-procedure DIP switch: Setting RS--C specifications Transmission speed: 0 00 bps Data bit: or bits Stop bit:,. or bits Parity: even or odd RS--C connector: -pin D-sub connector (female) (M. 0. screw connector) RS--C cable: straight (provided by the user) M-System's modems listed in Model & Suffix Code Selection section, for MOD, MOD and MOD, include RS--C cables. For the MOD, MOD, MOD and MOD, a RS--C cable, model DCN must be purchased separately. Configuration: each station is composed of a DLS and a modem unit. The paired DLS's are adjusted at the factory as Station A and Station B. INSTALLATION Power consumption AC: Approx.. VA max. DC: Approx. W max. (. A with V) Grounding: Not required in normal environments; 00 Ω or less grounding resistance in noisy environments Operating temperature: - to + 0 C ( to F) Operating humidity: 0 to 0 %RH (non-condensing) Atmosphere: No corrosive gas or heavy dust Mounting: Surface; Rack Mounting Frame (model: BX-DL) available Weight: kg (. lb) PERFORMANCE Permissible power failure duration: 0 ms Insulation resistance: 00 MΩ with 00 V DC Dielectric strength: 00 V AC @ minute (I/O to transmission to power) http://www.m-system.co.jp/ DLS SPECIFICATIONS ES- Rev. Page /0

DESCRIPTIONS RUN Contact (LED) Behaviors The LED operates when both the communication line conditions and DLS units conditions are true. Comm. line conditions Input units (00, A, A, G and P): The LED turns ON with the network configured; OFF in an abnormality; the network is reconfigured after an abnormality. Output units (C, C, C, C, M and U): The LED turns ON when data from the paired input unit is received normally, with the network configured; OFF when the data is lost; turns also OFF in an abnormality in the network. I/O-mixed units (E, E, R and S): Functions of both input and output units are used. DLS units conditions: The LED turns ON when the transmission is normal between the DLS units; OFF after three retries in a transmission abnormality. [CAUTION] When the network is reconfigured e.g. by noise interference, the RUN LED and output for all units on the network turn briefly OFF until they are turned ON after the reconfiguration is complete. How to Caculate Transmission Speed. Data Volume and Transmission Time of I/O Unit I/O type of DLS (or DLA) units determines each unit's multi-transmission time. The DLS collects data from each station and transmits to the other station. (Input Model Suffix: Data Volume) A, E: 0 bytes A: 0 bytes G, P: bytes R: bytes S: bytes C, C, C, C, M, U: 0 bytes Transmission time for unit is calculated utilizing each unit's data volume. Transmission time = (data volume) (number of data bits per byte transmission speed [bps]) + waiting time per unit (0. sec.) [example] Transmission time of type A, S and C units A unit (00 bps) 0 00 + 0. = 0. (sec.) S unit (00 bps) 00 + 0. =. (sec.) C unit 0 sec. Transmission time for those units with 0 data volume equals 0.. Start / End of Transmission The DLS transmits codes to the paired station at the start and end of transmission sequence respectively. The data volume differs according to modem type. (Modem Type: MOD/; Others) Start-of-transmission time: bytes; bytes End-of transmission time: bytes; bytes Start-of-Transmission time = (data volume) (number of data bits per byte transmission speed [bps]) + waiting time per unit (0. sec.) Remark: Waiting time for MOD and MOD is 0. sec. [example] Modem type /MA (00 bps) 00 + 0. = 0. (sec.) End-of-Transmission time = (data volume) (number of data bits per byte transmission speed [bps]) + waiting time per http://www.m-system.co.jp/ DLS SPECIFICATIONS ES- Rev. Page /0

unit (0. sec.) [example] Modem type /MA (00 bps) 00 + 0. = 0. (sec.). Total Transmission Time per Unit The above () transmission time and () & () Start-/End-of transmission time must be added to calculate the total transmission time required by one DLS unit. Total transmission time per unit = (start-of-transmission time) + (transmission time) + (end-of-transmission time) [example] Station A: S and A units Station B: S and C units Modem type /MA (00 bps) Station A transmission time 0. + (. + 0.) + 0. =. (sec.) Station B transmission time 0. + (. + 0) + 0. =. (sec.). Overall Transmission Cycle The overall transmission cycle is determined as the time required by one DLS unit starting transmission before the next transmission. Overall transmission cycle = Station A total transmission time + Station B total transmission time [example] Station A: S and A units Station B: S and C units Modem type /MA (00 bps). +. =. (sec.) The time required for the input signals to be output at the output unit varies according to the exact moment of input. Minimum (Station A input to Station B output) = Station A total transmission time per unit =. (sec.) Maximum (Station A input ot Station B output) = Overall transmission cycle + Station A total tansmission time per unit =.0 (sec.) Therefore, the time required for a Station A input to be output at the Station B varies between. and.0 seconds as far as there is no transmission error. http://www.m-system.co.jp/ DLS SPECIFICATIONS ES- Rev. Page /0

SYSTEM CONFIGURATION EXAMPLE multi-transmission line RS--C (straight) MOD DLA-A-K (station address SA = 0, SA = ) DLS-SAB-K/MA (station address SA = 0, SA = ) process I/O process I/O leased circuit multi-transmission line MOD RS--C (straight) process I/O DLS-SAB-K/MB (station address SA = 0, SA = ) process I/O DLA-C-K (station address SA = 0, SA = ) HOW TO SET STATION ADDRESSES The I/O units are connected in a series via a couple of modems. Set the station address to DLA units as described in the DLA data sheet. For the DLS with no process I/O, set a number remote from those for DLAs (such like FF, FE). When the DLS has process input or output, set it the same way as the DLA. HOW TO CONFIGURE MULTI-TRANSMISSION LINE Refer to the data sheet for DLA unit. http://www.m-system.co.jp/ DLS SPECIFICATIONS ES- Rev. Page /0

EXTERNAL VIEW Power LED DIP SWITCH RUN LED Indicator Station Address Setting Rotary Switches DIP Switches (Deleted with modem type /A) RS--C TRANSMISSION SECTION SA SA I / O SECTION LED ON OFF Transmission Speed Data Bit Stop Bit Parity With/Without Parity Check D-SUB PIN ASSIGNMENT FG SD RD RS CS DR SG CD ER RS--C Connection Example (straight type cable) Unit Side 0 Modem Side 0 FG SD RD RS CS DR SG CD ER MULTI-TRANSMISSION SECTION, PROCESS I/O SECTION & INDICATOR LED SECTION (Process I/O and indicator LED sections are provided only for process I/O type) Power LED Indicator TWISTED-PAIR Jumper Euro Terminal FIBER OPTICS Fiber Link Fiber Link Euro Terminal RUN LED Indicator Station No. Setting Rotary Switches I/O Indicator LEDs (Varies according to I/O types. See each I/O section of model DLA data sheet.) TWISTED-PAIR & FIBER Fiber Link Jumper Euro Terminal SA SA TRANSMISSION SECTION (See details to the left) 0 0 0 I / O SECTION (See details to the right) STANDARD TYPE (0-terminal connector) 0 0 0 0 DLS-A, C, C (FCN 0-pin connectors) LED Indicator Selector CN CN U L http://www.m-system.co.jp/ DLS SPECIFICATIONS ES- Rev. Page /0

CONNECTION DIAGRAM TWISTED-PAIR CABLE (transmission media code: ) FIBER OPTICS CABLE (transmission media code: ) TWISTED-PAIR & FIBER OPTICS (transmission media code: ) RS--C D-SUB RS--C D-SUB RS--C D-SUB FIBER - OPTIC Fiber Optics FIBER - OPTIC Fiber Optics FIBER - OPTIC Shielded Twisted-pair Cable + Shielded Twisted-pair Cable + JUMPER PIN* JUMPER PIN* RUN CONTACT OUTPUT RUN CONTACT OUTPUT RUN CONTACT OUTPUT EARTH (FG) EARTH (FG) EARTH (FG) POWER V( ) U(+) POWER V( ) U(+) POWER V( ) U(+) *When the unit is located at the end of transmission line via twisted-pair cable (= no cross-wiring), short across the terminals with the jumper pin (or wire) provided with the unit. Remove the jumper pin for all the unit not located at the end. DIMENSIONS unit: mm (inch) STANDARD TYPE SIDE MOUNTING (.) dia. [ (.0) deep] SURFACE MOUNTING M SCREW [ (.) deep] 0-pin Terminal Block 00 (.). (.) 0 (.) (.) (.) 0 M SCREW TERMINAL 0 0 0 0 (.0) (.0)* 00 (.) min. (.0) *For M-System s modem http://www.m-system.co.jp/ DLS SPECIFICATIONS ES- Rev. Page /0

WITH I/O S SIDE MOUNTING (.) dia. [ (.0) deep] SURFACE MOUNTING M SCREW [ (.) deep] Pin Assignment LED INDICATOR SELECTOR U L A B 00 (.) (.) CN A0 B0 A B CN A0 B0. (.) 0 (.) (.0) 0 (.) min. 00 (.) Terminal Assignment, Euro Type Terminals Wiring Procedure of Euro Type Terminals PIN TERMINAL PHOENIX CONTACT AI.-BK RECOMMENDED MULTI-STRAND CABLE:. mm (.0 in ) * SCREWDRIVER ( ) SOLID CABLE. mm (.0) dia. Remove cover. mm (.) *Not provided for fiber optics (Transmission media code ) Note : There is no specific order for connecting fiber optics. WITHOUT PROCESS I/O SIDE MOUNTING (.) dia. [ (.0) deep] SURFACE MOUNTING M SCREW [ (.) deep] 00 (.) (.). (.) 0 (.) (.0) 0 (.) min.* 00 (.) *For M-System s modem http://www.m-system.co.jp/ DLS SPECIFICATIONS ES- Rev. Page /0

MOUNTING REQUIREMENTS unit: mm (inch) SURFACE MOUNTING SIDE MOUNTING (terminal block at the right side). (.) (.) (.) M SCREW M SCREW MODEL: DLS (.) (.) 0 (.) WIRING SPACE (.) MIN. FUNCTION BLOCK DIAGRAM POWER TERMINALS MULTI-XMISSION TERMINALS TRANSMISSION SECTION Multi-Xmission Interface Isolation Circuit RUN Contact Output RUN Controller RUN LED CONTROL SECTION POWER LED RAM Network CPU Watch-dog Station No. Set SW EP ROM UART RS--C Common RAM or Latching Circuit *** I/O SECTION ** I/O CPU RUN LED I/O Controller Isolation Circuit I/O Driver * Contact I/O Indicator LEDs **** I/O TERMINALS ** MODULAR JACK * Not included with codes G, P, R or S. ** Not included with codes A, A, C, C, C, C, E or E. *** Not included when there is no process I/O. **** Not included with codes G, M or R. http://www.m-system.co.jp/ DLS SPECIFICATIONS ES- Rev. Page /0

Specifications are subject to change without notice. http://www.m-system.co.jp/ DLS SPECIFICATIONS ES- Rev. Page 0/0