1 INSTRUCTION MANUAL PULSE DURATION RECEIVER (field-programmable; built-in excitation) MODEL JTY JTY BEFORE USE... Thank you for choosing M-System. Before use, check the contents of the package you received as outlined below. If you have any problems or questions with the product, please contact M-System's Sales Office or representatives. PACKAGE INCLUDES: Signal conditioner (body base socket)... () MODEL NO. Check that model No. described on specification label is exactly what you ordered. INSTRUCTION MANUAL This manual describes necessary points of caution when you use this product, including installation and connection, hardware setting, operation of the Programming Unit (model: PU- x)* specific to this model and basic maintenance procedures. This unit is factory adjusted and calibrated according to the Ordering Information included in the product package. If you don t need to change the pre-adjusted setting, you can skip the sections on hardware setting and calibration and Software Setting in this manual. *When you need to change software settings, please refer to the Operation Manual for Model PU-x (EM-), Section B: (B-) Introduction, (B-) General Operation Description, (B-) Operation Flowchart for general information. POINTS OF CAUTION POWER INPUT RATING & OPERATIONAL RANGE Check the power rating for the unit on the specification label. V AC rating: V, Hz, approx. VA,, and V DC ratings: Rating ±0%, approx..w 0V DC rating: 0V DC, approx..w UNPLUGGING THE UNIT Before you remove the unit from its base socket or mount it, turn off the power supply and input signal for safety. ENVIRONMENT Indoor use When heavy dust or metal particles are present in the air, install the unit inside proper housing with sufficient ventilation. Do not install the unit where it is subjected to continuous vibration. Do not subject the unit to physical impact. Environmental temperature must be within - to 0 C ( to 0 F) with relative humidity within 0 to 0% RH in order to ensure adequate life span and operation. WIRING Do not install cables (power supply, input and output) close to noise sources (relay drive cable, high frequency line, etc.). Do not bind the unit's cables together with cables where high noise levels are present. Do not install them in the same duct. AND... The unit is designed to function as soon as power is supplied, however, a warm up for 0 minutes is required for satisfying complete performance described in the data sheet. COMPONENT IDENTIFICATION Body Connection Diagram Label Front Cover Specification Label Base Socket HOW TO OPEN THE FRONT COVER: Position your finger on the hook at the top of front cover and pull. INSTALLATION The shape of base socket may be different for some models. Detach the yellow clamps located at the top and bottom of the unit for separating the body from the base socket. DIN RAIL MOUNTING Set the base socket so that its DIN rail adaptor is at the bottom. Position the upper hook at the rear side of base socket on the DIN rail and push in the lower. When removing the socket, push down the DIN rail adaptor utilizing a minus screwdriver and pull. WALL MOUNTING Refer to the drawings in the next page. Clamp (top & bottom) DIN Rail mm wide Spring Loaded DIN Rail Adaptor Shape and size of the base socket are slightly different with various socket types. P. / EM- Rev.
2 JTY TERMINAL CONNECTIONS Connect the unit as in the diagram below or refer to the connection diagram label on top of the unit. DIMENSIONS mm (inch) CLAMP (top & bottom). (.) 0 (.) DIN RAIL mm wide 0 (.). (.). (.) dia. MTG HOLE (.) deep 0 (.) 0 (.) 0 (.) M. SCREW 0 0 (.) (.) [. (.)] 0 (.) When mounting, no extra space is needed between units. CONNECTION DIAGRAM 0 ALARM OUTPUT INPUT SENSOR EXCITATION U() V() OUTPUT POWER Input Connection Examples Dry Contact PWR kω -Wire Current Pulse Built-in Excitation -WIRE PICK-UP 00Ω PU-x MODULAR JACK Voltage Pulse External DC Supply PWR -WIRE PICK-UP DC SUPPLY 00Ω CHECKING ) Terminal wiring: Check that all cables are correctly connected according to the connection diagram. ) Power input voltage: Check voltage across the terminal with a multimeter. ) Input: Check that the input signal is within 0 00% of the full-scale. ) Output: Check that the load resistance meets the described specifications. MAINTENANCE Regular calibration procedure is explained below: CALIBRATION Warm up the unit for at least 0 minutes. Apply 0%, %, 0%, % and 00% input signal. Check that the output signal for the respective input signal remains within accuracy described in the data sheet. When the output is out of tolerance, recalibrate the unit according to the "ANALOG OUTPUT ADJUSTMENT" procedure. P. / EM- Rev.
3 0 0 0 JTY HARDWARE SETTING & CALIBRATION FRONT PANEL CONFIGURATION Modular Jack Input Monitor LED PL Detecting Level Adj. Detecting Level Adj. Pin Pulse Amplitude Selector Input Type Selector Sensor Excitation Adj. ON Zero Adj. Span Adj. PULSE AMPLITUDE (rotary switch) (*) Factory setting For voltage pulse input, select the pulse amplitude (V p-p) among the switch positions 0 through. For open collector or two-wire current pulse input, set the switch to. DO NOT SET to or. The power supply to the unit must be turned off when changing the setting. SW PULSE AMPLITUDE MAX. INPUT VOLTAGE V p-p 0V 0V p-p 0V 0 V p-p V 0V p-p 0V V p-p V 0. V p-p V 0. 0.V p-p 0.V (*) Open collector or two-wire current pulse DIP SWITCH SETTING (*) Factory setting SW is not used. The power supply to the unit must be turned off when changing the setting. Input Type INPUT TYPE SW SW SW SW thr. Open collector (*) ON OFF ON OFF Voltage pulse OFF OFF ON OFF Two-wire current pulse OFF ON ON OFF EXAMPLE : VOLTAGE PULSE with Amplitude V p-p, DC Offset.V Input type: Voltage Input amplitude: V p-p The rotary switch and DIP switch are configured as shown below. Rotary SW DIP SW ON EXAMPLE : VOLTAGE PULSE with Amplitude V p-p, DC Offset V Input type: Voltage Input amplitude: 0V p-p The rotary switch and DIP switch are configured as shown below. Rotary SW DIP SW ON DETECTING LEVEL A specific sensitivity scale is applied according to the pulse amplitude setting. The scaled input voltage is then compared to the preset detecting level. The scaled H level voltage must be higher than the detecting level so that the pulse state is accurately detected. SW PULSE AMPLITUDE SENSITIVITY SCALE V p-p /0 0V p-p /0 0 V p-p / 0V p-p / V p-p 0. V p-p 0. 0.V p-p 0 Open collector or two-wire current pulse How to Change the Detecting Level A pulse generator which can simulate the selected input type and waveforms with appropriate amplitude is required. ) Set the rotary switch and the DIP switch to an appropriate input type and pulse amplitude. ) Connect the positive probe of the pulse generator to the terminal, the negative probe to the terminal of the base socket. ) Set the pulse generator output to khz with the duty ratio 0%, and apply the signal to the transmitter. ) Connect the Programming Unit to the modular jack and execute [GROUP 0] [ITEM 0] to show the input duty ratio. ) Press [ENTER] key multiple times to adjust the detecting level until the display shows 0.00 ±0.%. This adjustment affects the transmitter s accuracy. Be sure to set the duty ratio within 0.% allowances. ) Confirm that the input monitor LED (PL) is ON (it should actually be flashing in khz). If the LED does not turn on, the detecting level may be out of the pulse amplitude range. Change the detecting level again. P. / EM- Rev.
4 JTY SENSOR EXCITATION ADJUSTMENT You can change the sensor excitation voltage with the sensor excitation adj. located behind the front cover. If you need to change it, check that the required current is within the specification. ALARM OUTPUT 0 OUTPUT INPUT SENSOR EXC. V Voltmeter A Ammeter PU-x MODULAR JACK U() V() POWER How to Change the Excitation A voltmeter and ammeter of class 0. or better accuracy are required. ) Connect the voltmeter across the terminals. ) Connect the ammeter to terminal. ) Turn the potentiometer until the meter shows the desired value. Check that the current value indicated on the ammeter is within the allowable limit. If the value is greater than the limit, lower the voltage value or connect a separate power source. Otherwise, the transmitter may fail. VOLTAGE (V) Voltage (V) Current (A) 00mW 0 0 CURRENT (ma) ANALOG OUTPUT ADJUSTMENT This unit is calibrated at the factory to meet the ordered specifications, therefore you usually do not need any calibration. For matching the signal to a receiving instrument or in case of regular calibration, adjust the output as explained in the following. How to Calibrate The Output Signal Use a signal source and measuring instruments of sufficient accuracy level. Turn the power supply on and warm up for more than 0 minutes. ) ZERO: Apply 0% input and adjust output to 0%. ) SPAN: Apply 00% input and adjust output to 00%. ) Check ZERO adjustment again with 0% input. ) When ZERO value is changed, repeat the above procedure ) ). P. / EM- Rev.
5 SOFTWARE SETTING JTY Please refer to the Operation Manual for Model PU-x (EM-), Section B: (B-) Introduction, (B-) General Operation Description, (B-) Operation Flowchart for general information. [GROUP 0] ITEM INPUT DATA EXAMPLE (EXAMPLE) DEFAULT CONTENTS MDF. CODE 0 S N/A MAINTENANCE SWITCH 0 MTSW : MON.MODE 0 : Data indication only. MTSW : PRG.MODE : All P marked parameters are modifiable. 0 P Alphanumeric TG : XXXXXXXXXX N/A Tag name entry (0 characters max.) 0 P Percentage OUTPER XXX.XX N/A Output monitor (%) & simulation output 0 D No input INPPER XXX.XX N/A Input monitor (%) 0 D No input INDUTY XXXXXX N/A Input duty ratio (%) 0 D No input N/A Input specification selected with the front rotary switch SW : IN_V /0 SW = 0, Voltage input, Sensitivity scale = /0 SW : IN_V /0 SW =, Voltage input, Sensitivity scale = /0 SW : IN_V / SW =, Voltage input, Sensitivity scale = / SW : IN_V / SW =, Voltage input, Sensitivity scale = / SW : IN_V / SW =, Voltage input, Sensitivity scale = / SW : IN_V / SW =, Voltage input, Sensitivity scale = / SW : IN_V 0/ SW =, Voltage input, Sensitivity scale = 0/ SW : IN_OC, ma SW =, Open collector or two-wire current input SW : no use SW =, (not used) SW : no use SW =, (not used) 0 P Numetic AVERAGE XX Cycles for the moving average calculation, 0 to 0 0 P Numetic HI CUT XX High samples to be discarded, 0 to 0 0 P Numeric LO CUT XX Low samples to be discarded, 0 to 0 P 0 Linearization 0 STRAIGHT Without CURVED With (ITEM 0 to for segment data input) P 0.00 Input zero duty ratio (two methods are available) Percentage ZERO XXX.XX. Enter a specific duty ratio in % ( %) XXX.XX. Apply a simulated input and press [DATA] [ENTER] P Input span duty ratio (two methods are available) Percentage SPAN XXX.XX. Enter a specific duty ratio in % ( %) XXX.XX. Apply a simulated input and press [DATA] [ENTER] P Percentage FINZER XXX.XX 0.00 Fine zero adjustment OUTPER XXX.XX When data is entered, output (%) is shown. 0 P Percentage FINSPN XXX.XX Fine span adjustment OUTPER XXX.XX When data is entered, output (%) is shown. P Alarm mode 0 NO ALARM No alarm trip UPPER ALARM High alarm trip LOWER ALARM Low alarm trip P Percentage ALARM XXX.XX 00.0 Alarm setpoint (- to %) P Percentage ALMHYS.00 Alarm deadband (hysteresis) (0 to 0%) P Seconds ALTIME.0 Alarm delay at the startup (.0 to seconds) P 0 No input alarm 0 TMOUT ALM : OFF Without (Hi/Lo setpoint alarm only, ITEM ) TMOUT ALM : ON With (Hi/Lo setpoint alarm no input alarm, ITEM ) P Seconds TMOUT XXXX.X.0 No input detecting time (0. to 00.0 seconds) When no input is detected for the specified time period, the duty ratio is forced to 00%/0%. P Input pulse logic 0 ACTIVE LO Non-inverted: Lo level with the voltage/current pulse or ON with the open collector is valid. ACTIVE HI Inverted: Hi level with the voltage/currrent pulse or OFF with the open collector is valid. P. / EM- Rev.
6 [GROUP 0] ITEM INPUT DATA EXAMPLE (EXAMPLE) DEFAULT CONTENTS MDF. CODE JTY 0 P Percentage X (0) : XXX.XX 0.00 Linearization table ( points) P Percentage Y (0) : XXX.XX 0.00 Set at the maximum of pairs of input (X) and output : : : : (Y) calibration points in %. Fill data from the lowest : : : : ITEM No. from the lowest calibration point and add as : : : : many as required. The output in the undefined range is 0 P Percentage X () : XXX.XX 0.00 maintained at the value of the first and the last P Percentage Y () : XXX.XX 0.00 calibration points. Modification Code D: No modification (writing) possible. Used only for monitoring (reading). S: Modifiable at any time. P: Modifiable only when the MAINTENANCE SWITCH is in the PRG mode. ROM Version Indication [GROUP 00] [ITEM ] LINEARIZATION TABLE The I/O curve is approximated at -point segments. Set only the required pairs of I/O points. Refer to the figure below. X (nn) : Input % Y (nn) : Output % Range : -.00 to.00% OUTPUT 00% Y0 Y0 X0 -% 0 -% Y0 Y0 Y0 X0 X0 X0 X0 % INPUT [GROUP 0] ITEM MDF. CODE DATA EXAMPLE 0 P X (0) : XXX.XX P Y (0) : XXX.XX P X (0) : XXX.XX P Y (0) : XXX.XX P X (0) : XXX.XX P Y (0) : XXX.XX P X (0) : XXX.XX P Y (0) : XXX.XX P X (0) : XXX.XX P Y (0) : XXX.XX 0 P X (0) : XXX.XX P Y (0) : XXX.XX P X (0) : XXX.XX P Y (0) : XXX.XX P X (0) : XXX.XX P Y (0) : XXX.XX P X (0) : XXX.XX P Y (0) : XXX.XX P X (0) : XXX.XX P Y (0) : XXX.XX 0 P X () : XXX.XX P Y () : XXX.XX P X () : XXX.XX P Y () : XXX.XX P X () : XXX.XX P Y () : XXX.XX P X () : XXX.XX P Y () : XXX.XX P X () : XXX.XX P Y () : XXX.XX 0 P X () : XXX.XX P Y () : XXX.XX Modification Code S:Modifiable at any time. P:Modifiable only when the MAINTENANCE SWITCH is in the PRG mode. P. / EM- Rev.
7 JTY NO INPUT DETECTING TIME When no input is detected for a preset time period, the transmitter provides an output equivalent to 0% or 00% duty ratio according to the input status. Select the time to be longer than the ON/OFF or Hi/Lo levels of the input pulse. INPUT LOGIC NON-INVERTED INVERTED Open collector OFF state longer than the preset Output equivalent to 00% duty ratio Output equivalent to 0% duty ratio input time period ON state longer than the preset Output equivalent to 0% duty ratio Output equivalent to 00% duty ratio time period Voltage pulse, H state longer than the preset Output equivalent to 00% duty ratio Output equivalent to 0% duty ratio Two-wire time period current pulse L state longer than the preset Output equivalent to 0% duty ratio Output equivalent to 00% duty ratio input time period M-SYSTEM WARRANTY M-System warrants such new M-System product which it manufactures to be free from defects in materials and workmanship during the -month period following the date that such product was originally purchased if such product has been used under normal operating conditions and properly maintained, M-System's sole liability, and purchaser's exclusive remedies, under this warranty are, at M-System's option, the repair, replacement or refund of the purchase price of any M-System product which is defective under the terms of this warranty. To submit a claim under this warranty, the purchaser must return, at its expense, the defective M-System product to the below address together with a copy of its original sales invoice. THIS IS THE ONLY WARRANTY APPLICABLE TO M-SYSTEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. M-SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES OF ANY KIND WHATSOEVER. M-System Co., Ltd., --, Minamitsumori, Nishinari-ku, Osaka -00 JAPAN, Phone: (0) -0, Fax: (0) -0, info@m-system.co.jp P. / EM- Rev.
JPQ2 PULSE ACCUMULATOR
INSTRUCTION MANUAL PULSE ACCUMULATOR (field-programmable; built-in excitation) MODEL JPQ JPQ BEFORE USE... Thank you for choosing M-System. Before use, check the contents of the package you received as
More informationWJM POTENTIOMETER TRANSMITTER BEFORE USE... COMPONENT IDENTIFICATION POINTS OF CAUTION INSTRUCTION MANUAL MODEL. (field-programmable)
INSTRUCTION MANUAL POTENTIOMETER TRANSMITTER (field-programmable) MODEL WJM BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.
More informationPPD COMPONENT IDENTIFICATION BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PULSE ISOLATOR MODEL. (built-in excitation)
INSTRUCTI MANUA PUSE ISOATOR (built-in excitation) MODE PPD BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you have any
More informationMODEL: M2DYS SEN TRONIC AG
Super-mini Signal Conditioners Mini-M Series CURRENT LOOP SUPPLY Functions & Features Powers a 20 ma DC current loop Short circuit protection Applicable to smart transmitters CE marking UL approval Typical
More informationMODEL: W2DYS SEN TRONIC AG. Mini-MW Series
MODEL: WDYS Space-saving Dual Output Signal Conditioners Mini-MW Series CURRENT LOOP SUPPLY Functions & Features Powers a 0 ma DC current loop Short circuit protection Applicable to smart transmitters
More informationJRQ2 ENCODER POSITION TRANSMITTER MODEL. Plug-in Signal Conditioners M-UNIT. (field-programmable; built-in excitation)
Plug-in Signal Conditioners M-UNIT ENCODER POSITI TRANSMITTER (field-programmable; built-in excitation) MODEL JRQ MODEL & SUFFIX CODE SELECTI JRQ MODEL SELECTI Open collector Voltage pulse RS- line driver
More informationn FRONT PANEL CONFIGURATIONS
INSTRUCTION MANUAL VALVE POSITIONER (for LonWorks; built-in SSR) MODEL MEXL MEXL BEFORE USE... Thank you for choosing M-System. Before use, check the contents of the package you received as outlined below.
More informationMODEL: M2SES SEN TRONIC AG [3] OUTPUT
Super-mini Signal Conditioners Mini-M Series HIGH/LOW SELECTOR Functions & Features Monitors two DC input signals and transmits an output signal proportional to the higher or lower input CE marking UL
More informationR7L-YV2. DC VOLTAGE OUTPUT MODULE, 2 points MODEL BEFORE USE... POINTS OF CAUTION COMPONENT IDENTIFICATION INSTRUCTION MANUAL R7L-YV2
INSTRUCTION MANUAL DC VOLTAGE OUTPUT MODULE, 2 points MODEL R7L-YV2 BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you
More informationMODEL: KS. Plug-in Signal Conditioners K-UNIT
Plug-in Signal Conditioners K-UNIT DC ALARM Functions & Features Providing relay contact closures at preset DC input levels Dual (Hi/Lo) trip Multi-turn screwdriver setpoint adjustments Monitor jacks provided
More informationNPN TRANSISTOR OUTPUT MODULE
INSTRUCTION MANUAL NPN TRANSISTOR OUTPUT MODULE (3 points, MECHATROLINK- I/II use) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as
More informationMODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value.
Super-mini Signal Conditioners Mini-M Series FREQUENCY TRANSMITTER (PC programmable) Functions & Features Converts the output from a pulse-type transducer into a standard process signal PC programmable
More informationMODEL: JB2. Plug-in Signal Conditioners M-UNIT
Plug-in Signal Conditioners M-UNIT ANALOG BACK STATION Functions & Features Enables manual loading providing hold/increase/ decrease signals to a device controlled by PID controller When the PID controller
More informationMODEL: JPR2. Plug-in Signal Conditioners M-UNIT
MODE: JPR Plug-in Signal Conditioners M-UNIT PUSE SCAER (field-programmable; built-in excitation) Functions & Features Converts pulse rate into convenient engineering unit for display on a totalizing counter
More information34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009
User s Guide Publication number 34134-90001 April 2009 For Safety information, Warranties, Regulatory information, and publishing information, see the pages at the back of this book. Copyright Agilent
More informationCTC CT TRANSMITTER. (clamp-on current sensor) BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MODEL CTC
INSTRUCTION MANUA CT TRANSMITTER (camp-on current sensor) MODE CTC CTC BEFORE USE... Than you for choosing M-System. Before use, chec the contents of the pacage you received as outined beow. If you have
More informationMODEL: DA3. Plug-in Signal Conditioners M-UNIT
Plug-in Signal Conditioners M-UNIT D/A CONVERTER (16-bit resolution) Functions & Features Converts parallel digital signal into a DC output BCD, binary, offset binary, two's complement, reflected binary
More informationMODEL: RPPD. Plug-in Signal Conditioners M-UNIT. [2] INPUT 2 Must be the same code as the one chosen for Input 1.
MODE: RPPD Plug-in Signal Conditioners M-UNIT PUSE ISOATOR (built-in excitation; rotary encoder use) Functions & Features Galvanically isolating two pulse rate signals from a rotary encoder Various outputs
More informationDISCRETE INPUT MODULE, 16 points
INSTRUCTION MANUAL DISCRETE INPUT MODULE, points (Modbus) RM-DA MODEL RM-DA BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.
More informationInstruction Manual Inductive Gauging Sensor
Instruction Manual Inductive Gauging Sensor EX-200 Series 96M0367 CONTENTS Page Part names and functions...3 Connections/Hints on correct use... 4 Installations... 5 Adjustment... 6 Specifications... 7
More informationPIECAL Model 541 Frequency Calibrator with Totalizer Operating Instructions
PIECAL Model 541 Frequency Calibrator with Totalizer Operating Instructions Easy to use With the Model 541 you can check & calibrate all your frequency instruments and measure flow sensors. Take it into
More information8003 1/8 DIN Temperature Controller
8003 1/8 DIN Temperature Controller Issue Date April 1994 USER S MANUAL 0037-75212 Contents Model Identification... Page ii Dimensions and Panel Cutout...1 Wiring...2 Hardware Setup...3 Configuration Mode...4
More informationMODEL: M6SXU MODEL: M6SXU [1][2] [3][4]
Tension-Clamp Ultra-Slim Signal Conditioners M6S Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection Universal input (mv, V, ma, T/C, RTD and potentiometer)
More informationAMP-13 OPERATOR S MANUAL
AMP-13 OPERATOR S MANUAL Version 2.0 Copyright 2008 by Vatell Corporation Vatell Corporation P.O. Box 66 Christiansburg, VA 24068 Phone: (540) 961-3576 Fax: (540) 953-3010 WARNING: Read instructions carefully
More informationTMP-100 Turbine Meter Pulse Divider Circuit
NUFLO TM TMP-100 Turbine Meter Pulse Divider Circuit User Manual Manual No. 9A-100080245, Rev. 01 2008 Cameron International Corporation ( Cameron). All information contained in this publication is confidential
More informationOPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE
OPERATION & SERVICE MANUAL FOR FC 100 SERIES AC POWER SOURCE FC 110 AC POWER SOURCE VERSION 1.3, April 2001. copyright reserved. DWG No. FC00001 TABLE OF CONTENTS CHAPTER 1 INTRODUCTION... 1 1.1 GENERAL...
More informationOPERATION MANUAL LDM-1000
OPERATION MANUAL LDM-1000 TE CONNECTIVITY SENSORS /// LDM-1000 OPERATION MANUAL P/N 09290100-000 REV. C 05/2016 Page 1 Table of Contents 1. Introduction...3 2. Product Specifications...3 3. Product Description...4
More informationOrdering Information. Stepping Relay Unit G9B. Model Number Legend
Stepping Relay Unit CSM DS_E_4_1 Ideal for Controlling Pumps and Production Lines with Six or Twelve Stepping Circuits Built-in relays switch 2 A at 250 VAC or 30 VDC. Initialization of stepping with reset
More informationFits Tiger 320 Series UNIVERSAL FREQ/COUNTER INPUT MODULE
Fits Tiger 320 Series UNIVERSAL /ER INPUT MODULE Sensor. Magnetic, Namur, Source, Sink. De-coupling. 0.02 Hz high pass filter. Signal Type., (mv) or digital logic. Input Connector. Freq. Input (CH) Up/Down
More informationTRANSDUCER IN-LINE AMPLIFIER
TRANSDUCER IN-LINE Voltage Model AMPLIFIER 2080 Arlingate, Columbus, Ohio 43228, (614) 850-5000 Sensotec, Inc. 2080 Arlingate Lane Columbus, Ohio 43228 Copyright 1995 by Sensotec, Inc. all rights reserved
More informationMODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]
Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels CE marking
More informationDIGEM f 96 x 48 EK. Applications. Description
3-349-002-03 1/7.98 Front panel dimensions: 96 x 48 mm LED display: red or green, 14 mm high Max. display range: 19 999 to + 32 765 Modular connectors for flexible use Simple adjustments at front panel
More informationDigi-Stop. Installation & Operation
Digi-Stop Installation & Operation WARRANTY Accurate Technology, Inc. warrants the ProScale Systems against defective parts and workmanship for 1 year commencing from the date of original purchase. Upon
More informationSingle-phase Current Relay
New Product Single-phase Current Relay K8AB-AS Ideal for current monitoring for industrial facilities and equipment. Monitor for overcurrents or undercurrents. Manual resetting and automatically resetting
More informationPARALLEL MULTI-AMP KIT for 7200 Series AMPLIFIERS INSTRUCTION SHEET
2 5 0 7 W a r r e n S t r e e t, E l k h a r t, I N 4 6 5 1 6 U S A 5 7 4. 2 9 5. 9 4 9 5 w w w. A E T e c h r o n. c o m PARALLEL MULTI-AMP KIT for 7200 Series AMPLIFIERS INSTRUCTION SHEET Kit Contents:
More informationMODEL: AS4V. Plug-in Signal Conditioners M-UNIT
Plug-in Signal Conditioners M-UNIT DC ALARM (dual or quad alarm trip; field-configurable) Functions & Features Provides relay outputs at preset DC input levels Quad or dual trip Setting and display in
More informationTECHNICAL MANUAL. SERIES AP5103 DIN-Rail DC Strain Gage Conditioner ISO 9001/AS9100
TECHNICAL MANUAL SERIES AP5103 DIN-Rail DC Strain Gage Conditioner ISO 9001/AS9100 Due to the nature of technology, changes are inevitable. For latest technical specifications, see our website. Copyright
More informationPhase-sequence Phase-loss Relay
Phase-sequence Phase-loss Relay K8AB-PH Three-phase Phase-sequence Phase-loss Relay Using Voltage Detection Method Prevents reverse motor rotation due to incorrect wiring. Distinguishes between positive
More informationProcess Calibrator. TechChek 820
Process Calibrator TechChek 80 CONTENTS GENERAL... TURN ON... CONNECTIONS... TILT STAND...4 CHANGING BATTERIES...4 RESTORING DEFAULT SETTINGS... CONFIGURING TEMPERATURE SCALES... ENABLING AUTO-OFF... SELECTING
More informationMODEL UBP-10 UNIVERSAL IN-LINE TRANSDUCER AMPLIFIER BI-POLAR SUPPLY, 0-10 VOLT OUTPUT
MODEL UBP-10 UNIVERSAL IN-LINE TRANSDUCER AMPLIFIER BI-POLAR SUPPLY, 0-10 VOLT OUTPUT 2080 Arlingate Lane, Columbus, Ohio 43228 (614) 850-5000 Sensotec, Inc. 2080 Arlingate Lane Columbus, Ohio 43228 Copyright
More information15 Amp Digital High Frequency PWM Motor Speed Controller SPD-315-D and SPD-315-DS
15 Amp Digital High Frequency PWM Motor Speed Controller SPD-315-D and SPD-315-DS The SPD-315-D(S) PWM controller allows you to control the speed of a motor, brightness of a lamp or other load using a
More informationModel Number Structure
Current Sensor CSM DS_E Solid-state, Plug-in Current Sensor Applicable to motor overcurrent protection and 3-phase AC current detection. Inverse-type, start-up lock type, and instantaneous type overcurrent
More informationStatus Indicator LED PWR LINK COL
INSTRUCTION MANUAL DC VOLTAGE/CURRENT INPUT MODULE, 4 points (Ethernet Modbus/TCP) MODEL RE-SV4 RE-SV4 BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you
More informationGlass Electrode Meter
Glass Electrode Meter INSTRUCTION MANUAL FOR Glass Electrode R/C Meter MODEL 2700 Serial # Date PO Box 850 Carlsborg, WA 98324 U.S.A. 360-683-8300 800-426-1306 FAX: 360-683-3525 http://www.a-msystems.com
More informationFirmware Version d & higher Installation & Operation
DIGI LCD Readout Firmware Version d 2.100 & higher Installation & Operation Warranty Accurate Technology, Inc., warrants this product against defective parts and workmanship for 1 year commencing from
More information2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free
2001A 200KHz Function Generator Instruction Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com WARRANTY Global Specialties
More information10 Amp Digital PWM Motor Speed Controller CV-2110-HD and CV-2110-HDS
10 Amp Digital PWM Motor Speed Controller CV-2110-HD and CV-2110-HDS The Analog / Digital PWM controller allows you to control the speed of a motor, brightness of a lamp or other device using an analog
More informationG7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information
Latching Relay CSM DS_E Compact Mechanical Lock Latching Relays with Manual Buttons Compact design with a height of 7 mm, width of. mm, and depth of 8. mm. Plus, one Relay only weighs 7 g. Quick set and
More informationDIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL- KM 2782 / 2782-T
DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL- KM 2782 / 2782-T KM 2782 V 400A POWER G 17,Bharat Industrial Estate, T. J. Road, Sewree (W), Mumbai - 400 015. INDIA. Sales Direct : (022) 24156638 Tel. :
More informationMODEL: M5CTC SEN TRONIC AG
MODE: M5CTC Super-mini Termina Boc Signa Conditioners M5-UNIT CT TRANSMITTER (camp-on current sensor) Functions & Features Converts an aternating current into a standard process signa Easy-to-insta camp-on
More informationModel Number Structure
Single-phase Voltage Relay CSM DS_E_3_1 Ideal for voltage monitoring for industrial facilities and equipment. Monitor for overvoltages or undervoltages. Manual resetting and automatically resetting supported
More information305 Stimulus Isolator. Description
Description The Model 305 Stimulus Isolator utilizes photon coupling to provide nearly ideal isolation of the pulse and train outputs of the WPI Series 300 Anapulse Stimulators. Two Model 305 units are
More information47D Series Digital Panel Meters Modbus Protocol Reference Guide CONTENTS 1. INTRODUCTION MODBUS PROTOCOL MODBUS REGISTERS...
47D Series Digital Panel Meters Modbus Protocol Reference Guide CONTENTS 1. INTRODUCTION...2 2. MODBUS PROTOCOL...3 2.1 GENERAL DESCRIPTIONS...3 2.2 TRANSMISSION SETTING...3 2.3 SYSTEM CONFIGURATION EXAMPLES...4
More informationOrdering Information. Ratchet Relay G4Q. Plug-in Models. Model Number Legend
Ratchet Relay CSM OEE_DS_E_1_1 Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation Each contact in the double-pole contact mechanism performs alternate make-brake operation
More informationMODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series
Digital Panel Meters 47 Series FREQUENCY INPUT DIGITAL PANEL METER (4½ digit, LED display type) Functions & Features 4 ½ digit digital panel meter 1/8 DIN size Accepts a pulse train input to measure rotation
More informationMODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]
MODEL: MMNV Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels
More informationRadio Remote Controls Manual K Series
Radio Remote Controls Manual K Series PN 52764 2010.12.20 Rev. 2 K Series radio control manual 1 Conductix Incorporated The technical data and images which appear in this manual are for informational purposes
More informationTRANSDUCER IN-LINE AMPLIFIER
TRANSDUCER IN-LINE Bi-Polar Model AMPLIFIER 2080 Arlingate Lane, Columbus, Ohio 43228 (614) 850-5000 Sensotec, Inc. 2080 Arlingate Lane Columbus, Ohio 43228 Copyright 1995 by Sensotec, Inc. all rights
More informationMODEL: M6SXT. POWER INPUT DC Power R: 24 V DC
Tension-Clamp Ultra-Slim Signal Conditioners M6S Series THERMOCOUPLE TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection 5.9-mm wide ultra-slim design Low profile
More informationMY-GS CSM_MY-GS_DS_E_2_1
Miniature Power Relays CSM DS_E 1 Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays Reduces wiring work by % when combined with the PYF-PU Push-In Plus Socket
More informationTransmitter. User Manual. Firmware version 1.0 and greater
ProRF SPC Transmitter User Manual Firmware version 1.0 and greater FCC NOTICE This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the
More informationSC200 Series. Signal Conditioner MNX10020, REV H 10/17/ Connection Technology Center, Inc Rae Boulevard Victor, NY (585)
SC200 Series Signal Conditioner MNX10020, REV H 10/17/2012 1 CONTENTS SECTION 1: OVERVIEW... 4 Introduction... 4 Description... 4 Ordering Information... 4 Specifications... 5 Environmental... 5 Electrical...
More informationAC 24, 110, 120, 230, 240 DC 6, 12, 24, 48 LED indicator with test button G2R-1-SNI (S) G2R-2-SNI (S) Diode
General-purpose Relay CSM_G2R-_-S_(S)_DS_E 3 Slim and Space-saving Power Plug-in Relay Reduces wiring work by 60% when combined with the P2RF-@-PU Push-In Plus Socket (according to actual OMRON measurements).
More informationFour-quadrant fast response bi-polar power supply
Compact high speed bi-polar power supply DJOP Series NEW Four-quadrant fast response bi-polar power supply DJOP series Output voltage : 0 V to ±60 V Maximum output power : 50W, 60 W Frequency bandwidth
More informationPOWER SERIES Plus. Volt / Amp / Hertz. Digital Switchboard Meter. User s Manual IM2493VAF-3
POWER SERIES Plus Volt / Amp / Hertz Digital Switchboard Meter User s Manual General Description The POWER SERIES Plus digital switchboard meters incorporate the latest DSP microprocessor technology. Careful
More informationG70R-SOC08 CSM_G70R-SOC08_DS_E_2_1
Relay Terminal CSM DS_E 1 Space-saving and Labor-saving 8-point Output Block Relay terminal is just 136 80 55 mm (W H D, when mounted upright). Independent contacts and short bar allow easy common connections.
More informationSingle-phase Voltage Relay
New Product Single-phase Voltage Relay K8AB-VS Ideal for voltage monitoring for industrial facilities and equipment. Monitor for overvoltages or undervoltages. Manual resetting and automatically resetting
More informationDigi-Fence. User Manual for: Digi-Fence (all models) Digital Readout Firmware version d & Higher
Digi-Fence User Manual for: Digi-Fence (all models) Digital Readout Firmware version d 2.000 & Higher Warranty Accurate Technology, Inc., warrants this product against defective parts and workmanship for
More informationUser s Guide. 400A AC/DC Clamp Meter. Model MA220
User s Guide 400A AC/DC Clamp Meter Model MA220 Introduction Thank you for selecting the Extech MA200 AC/DC Clamp Meter. This meter measures AC/DC Current, AC/DC Voltage, Resistance, Capacitance, Frequency,
More informationFour-Channel Differential AC Amplifier
Four-Channel Differential AC Amplifier INSTRUCTION MANUAL FOR HIGH-GAIN DIFFERENTIAL AMPLIFIER MODEL 1700 Serial # Date A-M Systems, Inc. PO Box 850 Carlsborg, WA 98324 U.S.A. 360-683-8300 800-426-1306
More informationCIRCUIT-TEST ELECTRONICS
USER'S MANUAL Sweep Function Generator with Counter SWF-8030 CIRCUIT-TEST ELECTRONICS www.circuittest.com TABLE OF CONTENTS SAFETY INFORMATION...page 3 INTRODUCTION... 4 SPECIFICATIONS... 5 FRONT PANEL
More informationDual T/C & RTD Calibrator With Auto Stepping
Model 525 Dual T/C & RTD Calibrator With Auto Stepping Practical Instrument Electronics Operating Instructions Basic Keypad Operations j EZ-Check Switch For Simulation - Slide the switch to select from
More informationCCE Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault
CCE-32 1.09 Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault Index 1. General description... 5 2. Applications... 5 3. Installation... 5 4. Connections...
More informationInstruction Sheet REB SERIES. Rotating Sliding Base REB18
Instruction Sheet REB SERIES Rotating Sliding Base REB14 REB18 THANK YOU Thank you for purchasing the REB Series Rotating Sliding Base. Please read these instructions thoroughly before installing this
More informationINSTRUCTIONS PS2500 POWER SUPPLY
INSTRUCTIONS PS2500 POWER SUPPLY The Hoefer PS 2500 Power Supply will furnished power to Constant Voltage or Constant Power modes of operation. It will accurately supply 0-2500 volts, 0-300 ma or 0-375
More informationUser Manual. ProRF Encoder Transmitter & Receiver
User Manual ProRF Encoder Transmitter & Receiver WARRANTY Accurate Technology, Inc. warrants the ProScale Systems against defective parts and workmanship for 1 year commencing from the date of original
More informationUser's Guide. Wireless AC Circuit Identifier. Models RT30 and RT32
User's Guide Wireless AC Circuit Identifier Models RT30 and RT32 Introduction Congratulations on your purchase of Extech s Model RT30 (914Mhz) or RT32 (869MHz) Wireless AC Circuit Identifier. The detector
More information80i-600A AC Current Probe
x Instruction Sheet 80i-600A AC Current Probe INTRODUCTION The Model 80i-600A is a clamp-on ac current probe designed to extend the current measuring capability of an ac current meter to 600 amperes. A
More informationUser s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130
User s Guide MultiView Series Digital MultiMeters Models: MV110 MV120 MV130 WARRANTY EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year
More informationINSTRUCTION MANUAL TIMER -X UNIVERSAL TIMER
FILE: IM_091-214-12_revA.indd REV: A REVISED BY: thn DATE: 02-22-2013 INSTRUCTION MANUAL TIMER -X UNIVERSAL TIMER (duty cycle, dodo,dopi) picture of product MODEL #091-214-12 INPUT: 12VDC or 110-250 VAC
More information40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR
40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR The BIDIR-340-DR is a fully solid-state motor controller that allows you to control the speed and direction of a
More informationMODEL: M2XU MODEL: M2XU [1][2] [3][4]
Super-mini Signal Conditioners Mini-M Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Accepts direct inputs from various sensors and provides a standard process signal I/O types and
More informationSeries APD4059. For Load Cells/Pressure Transducer Transmitters. Field Rangeable, with Calibration Resistor. Standard Features.
TECHNICAL MANUAL Series APD4059 For Load Cells/Pressure Transducer Transmitters. Field Rangeable, with Calibration Resistor Standard Features Use Internal or External Calibration Resistor Sense Lead Compensation
More informationInstruction Sheet. VRS Series. Vertical Rackmount system for multiple cable/satellite receivers
Instruction Sheet VRS Series Vertical Rackmount system for multiple cable/satellite receivers THANK YOU Thank you for purchasing the VRS Vertical Rackmount System. Please read these instructions thoroughly
More informationModel TS. Transducer Simulator User s Guide. Sensotec Sensors
Model TS Transducer Simulator User s Guide Sensotec Sensors Honeywell Sensotec Sensors 2080 Arlingate Lane Columbus, OH 43228, USA Telephone: (614)850-5000 Fax: (614) 850-1111 Toll Free: 1-800-848-6564
More informationDigi-Fence. User Manual (all models) For All Models with Digital Readout Firmware version d & Higher
Digi-Fence User Manual (all models) For All Models with Digital Readout Firmware version d 2.000 & Higher Warranty Accurate Technology, Inc., warrants this product against defective parts and workmanship
More informationModel 1791 VHF Radio User's Manual
Model 79 VHF Radio User's Manual ALL WEATHER INC 65 NATIONAL DRIVE SACRAMENTO, CA 95834 WWW.ALWEATHERINC.COM 79 VHF RADIO USER'S MANUAL CONTENTS INTRODUCTION... Description... Transmitter Module... Power
More informationAUTOMATION. Operator s Manual. IRU-2xx4/3xx4 Series. Rev. A2, 11/08 Doc
AUTOMATION P R O D U C T S G R O U P, I N C. Operator s Manual IRU-2xx4/3xx4 Series Rev. A2, 11/08 Doc. 9002673 Tel: 1/888/525-7300 Fax: 1/435/753-7490 www.apgsensors.com E-mail: sales@apgsensors.com IRU-2xx4/3xx4
More informationFirmware Version d & higher Installation & Operation
DIGI LCD Readout Firmware Version d 2.100 & higher Installation & Operation READOUT SERIAL # SCALE SERIAL # TO MAXIMIZE THE ACCURACY OF YOUR SYSTEM, THE FOLLOWING PROGRAMMING PARAMETER HAS BEEN PRE-CONFIGURED
More informationAMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH
AMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH INSTRUCTION MANUAL PLEASE READ THIS MANUAL BEFORE OPERATING THIS EQUIPMENT! 116 Willow Road Starkville, MS 39759 USA 662-323-8211 Version 3B Printed in U.S.A.
More informationInstallation & User Guide. For Powering Distributed Audio Systems A45-X2 TWO CHANNEL AMPLIFIER
Installation & User Guide For Powering Distributed Audio Systems TWO CHANNEL AMPLIFIER A45-X2 A45-X2 TWO CHANNEL AMPLIFIER TABLE OF CONTENTS Features...1 Product Overview...2 Package Contents...4 Preparing
More informationCHECK LINE INSTRUMENTS. ! Tolerates a wide variation of voltages. ! Immune to electrically noisy environments.
Panel Mount Tachometer Model DT-5TG (VDC) CHECK LINE INSTRUMENTS ELECTROMATIC E Q U I P M E N T C O., I N C. 600 Oakland Ave., Cedarhurst, NY 11516 U.S.A. TEL: 516-295-4300 FAX: 516-295-4399 Instruction
More informationINSTRUCTION MANUAL LM192 LIGHT METER ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING CONTENTS. Precautions 1. SAFETY INFORMATION
ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING LM9 LIGHT METER Thank you for buying one of our products. For safety and a full understanding of its benefits please read this manual before use. Technical
More informationP5100A & P5150 High Voltage Probes Performance Verification and Adjustments
x P5100A & P5150 High Voltage Probes Performance Verification and Adjustments ZZZ Technical Reference *P077053001* 077-0530-01 xx P5100A & P5150 High Voltage Probes Performance Verification and Adjustments
More informationSL300 Snow Depth Sensor USL300 SNOW DEPTH SENSOR. Revision User Manual
USL300 SNOW DEPTH SENSOR Revision 1.1.2 User Manual 1 Table of Contents 1. Introduction... 3 2. Operation... 3 2.1. Electrostatic Transducer... 4 2.2. SL300 Analog Board... 4 2.3. SL300 Digital Circuit
More informationAMP-12 OPERATOR S MANUAL
AMP-12 OPERATOR S MANUAL Version 1.0 Copyright 2002 by Vatell Corporation Vatell Corporation P.O. Box 66 Christiansburg, VA 24068 Phone: (540) 961-3576 Fax: (540) 953-3010 WARNING: Read instructions carefully
More informationCT-2 and CT-3 Channel Taggers OPERATION MANUAL
CT-2 and CT-3 Channel Taggers OPERATION MANUAL Trilithic Company Profile Trilithic is a privately held manufacturer founded in 1986 as an engineering and assembly company that built and designed customer-directed
More informationD7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information
with Linear Output or Manual Setting Detects Changes in Machine ON/OFF output can be set and checked quickly and easily from the vibration level meter. waveforms can be checked using the AC monitor output.
More informationDIGITAL SOUND LEVEL DSM8930 METER USER S MANUAL. Please read this manual carefully and thoroughly before using this product.
DIGITAL SOUND LEVEL METER USER S MANUAL DSM8930 Please read this manual carefully and thoroughly before using this product. TABLE OF CONTENTS Introduction.............................. 2 3 Key Features................................
More informationPM-311x Quick Start Ver PM-311x introduction 1.1. Caution & Warning 1.2. Product Warranty & Customer Support
PM-311x Quick Start Ver. 1.1 1. PM-311x introduction ICP DAS brings the most powerful, cost-effective, advanced Smart Power Meters PM-3000 series that gives you access to real-time electric usage for single-phase
More information