General Specifications
|
|
- Anthony Bishop
- 6 years ago
- Views:
Transcription
1 General Specifications GS 77J0A070E Model VJA7 Distributor (Multifunction) (Isolated Singleoutput and Isolated Dualoutput Types) Overview This plugin type distributor is used in combination with wire type transmitter and converts to 0 ma DC signal into isolated DC current or DC voltage signal. DC voltage signal, DC current signal, communication output (RS8), or alarm output ( relay contacts) is selectable as output. Selection of square root extractor and breakpoint linearization (breakpoint setting), I/O adjustment, I/ O monitoring, and loop back test can be made using the optional Parameter Setting Tool (VJ77) or Handy Terminal (JHT00). Can be used as a limiter converter when you use a breakpoint linearization function. Supports BARD800. Model and Suffix Codes VJA70 Model Output : output : outputs Power : 000 V AC/DC (Operating range: 8 to V) 7: 0 V DC (Operating range: to V) Signal A: to 0 ma DC ( power supply:. ± 0. V DC) Output Signal A: to 0 ma DC : to V DC Z: (Custom Order) DC current/voltage signal Output Signal A: to 0 ma DC : to V DC P: Communication function (RS8) T: Alarm output ( relay contacts) N: No output Options /SN: No socket (with socket if not specified) /C0: HumiSeal coating * /FB: Fuse bypass * *. When option code /C0 or /FB is specified, the conformity to the safety and EMC standards is excluded. CE marking is not applicable. (Note ) "/C0" option: Polyurethane coating. The "/C0" (Humiseal coating) option does not guaranteed the coating effect though it is expected that the corrosion resistance for electric is reinforced. And it is not able to submit coating test data. (Note ) "/FB" option: The primary power supply fuse is deleted, short and ship it. 0/ Ordering Information Shipped after setting the value of square root extraction, low cut point as specified. Model and suffix code: e.g. VJA70AA0 Square root (required item) : e.g. YES Low cut point (%): e.g. 0. * When specifying Without square root, the specification of low cut point (%) is unnecessary. Factory Default Settings Factory settings are as follows: To change the set value, a PCbased Parameter Setting Tool (VJ77) or Handy Terminal (JHT00) is required. Low cut point (%): 0. Linearizer: None Software filter: OFF Output operating direction: Direct When output is specified as communication output Address No.: 0 Communication rate: 00 bps Parity: Even Data length: 8 bit Stop bit: bit Protocol: PCLINK When output is specified as alarm output Alarm operating direction: High limit alarm (alarm), low limit alarm (alarm ) Relay operating direction: Energized under alarm condition (alarm / ) Alarm setting: 00 % (alarm), 0 % (alarm) Hysteresis: % (alarm / ) Alarm ondelay: 0 second (alarm / ) Alarm off delay: 0 second (alarm / ) GS 77J0A070E Copyright July (MC) 7th Edition Feb. 07 (YK)
2 Specifications Signal: to 0 ma DC from wire transmitter, point Resistance: 0 Ω Power : to. V DC (with current limit at to ma) Permissible Conductance Resistance: RL (0 transmitter minimum operating voltage) V/0.0 A (Ω) Permissible Current: 0 ma or less Square Root Extraction Function: Outputted against the result of extracting square root of input. Y= X (input 0 % value) x(output span)(output 0 % value) input span Lowcut Function: Available only when the square root extraction function is specified. Setting Range: 0 to 00 % of input, setting available by 0. % notch Output lowcut point or less is cramped with straight line proportional to input. Output signal (Y) Y=X. Output Analog Output Output Signal Output Resistance Permissible Load Resistance to V DC Ω or less kω or more to 0 ma DC 00 kω or more 0 Ω or less Output variable range: to 0 % (Both output and output ) Output adjustment: ±0 % (Zero/Span) (Output and output ) Break Point Linearization (Output/output): Breakpoint: Up to points (Set a relationship between input and output with % value over the span.) Allowable setting range of breakpoint: to 0 % (both input and output) With significant digits; can be set to the second place of a decimal point. Set breakpoints according to the following. For input:.0 % X 0 < X < X X n < X n 0.0 % For output:.0 % Y 0 to Y n < 0.0 % Output signal Y n 0 Hysteresis (0. % fixed) signal (X) Lowcut point Y n adjustment range: ±% of span or more (Zero/ Span) Software filter: OFF, Low, Middle, High (default value: OFF) When Low, Middle, or High is selected, a firstorder filter equivalent to 00 ms, 00 ms, or s is inserted in the input. Output Specifications. Output Output Signal Output Resistance Permissible Load Resistance to V DC Ω or less kω or more to 0 ma DC 00 kω or more 70 Ω or less Custom Order Output Signal to 0 ma DC, to ma DC, 0 to 0 ma DC, 0 to ma DC, 0 to 0 ma DC, 0 to ma DC, 0 to 0 mv DC, 0 to 00 mv DC, 0 to V DC, 0 to 0 V DC, 0 to V DC, 0 to 0 V DC X n X n signal Communication Function This distributor can be connected to a personal computer, graphic panel, YOKOGAWA programmable controller FAM, or programmable controllers of other manufacturers. Standards: EIA RS8 Maximum number of connectable units: units Maximum communication distance: 00 m Communication method: wire half duplex, startstop synchronization, nonprocedural Communication rate: 00, 00, 800, 00, 00, or 800 bps Data length: 8, 7 bit Stop bit:, bit Parity: Even parity, odd parity, or none Communication protocol: PClink, PClink with SUM, MODBUS ASCII, MODBUS RTU, or LADDER PClink communication: Communication protocol with a personal computer, graphic panel, or UT link module of FAM All Rights Reserved. Copyright, Yokogawa Electric Corporation GS 77J0A070E Feb. 0, 0700
3 MODBUS communication: Communication protocol with a personal computer (SCADA). Ladder communication: Communication protocol with ladder communication module of FAM and programmable controller of other manufacturers. Alarm Output Signal type: Relay contact Output signal: N. O. contact output (contact ON at excitation) points, common Contact capacity: 0 V DC, A Alarm operating direction: High limit alarm or low limit alarm Relay operating direction setting: Energized or deenergized under normal condition Alarm setting range: 0 to 00 % Setting resolution: 0. % Hysteresis: Set the value added to alarm setting point at alarm release. Setting range: 0 to 00 % of input range Setting resolution: 0. % Alarm on delay setting: Delay time from alarm condition completion to output (Ex. Outputted when alarm status continues for second or more after input value is over alarm point in case of set value second. ) Setting range: 0 to seconds Setting resolution: second (however, add about 0. seconds to setting time to prevent wrong operation) Alarm offdelay setting: Delay time from alarm normal condition completion to output (Ex. Released when normal status continues for seconds or more after input value becomes normal status from alarm status in case of set value seconds. ) Setting range: 0 to seconds Setting resolution: second (however, add about 0. seconds to setting time to prevent wrong operation) Alarm operation display: Front LED lights at excitation, LEDs Items Available to Be Set The following items can be set through PCbased Parameters Setting Tool (VJ77 sold separately) or Handy Terminal (JHT00 sold separately): Square root extraction, lowcut, address number, communication rate, parity, data length, stop bit, protocol, alarm operating direction, relay operating direction, alarm setting, hysteresis, alarm ondelay, alarm offdelay, output operating direction, linearization, software filter Standard Performance Accuracy Rating: ±0. % of span However, the accuracy is not guaranteed for output levels less than 0.% of the span of a 0 to X ma output range type. For square root extractor input, ±% of span when the input is % or less. If or more is set for the line segment gain of linearization, multiply the input/output accuracy by the value of line segment gain. Line segment gain (slope) is the maximum value calculated from the following expression. Linearizer gain Y n Y n X n X n Response Speed: 0 ms, % response (0 to 0 %) Alarm output: 0 ms (input change 0 to 0 %, alarm setting point 0 %, time till alarm output, when alarm delay setting and lockup width are min.) If the software filter is on, add the following to the value above: Low: 00 ms, Middle: 00 ms, High: s. The value of the A and then added to the abovementioned. Effect of Power Voltage Fluctuation: Accuracy range or less of span for power supply voltage fluctuation. Effect of Ambient Temperature Change: ±0. % or less of span for change of 0 C Safety and EMC Standards CSA: CSA. No. 00, installation category II *, pollution degree *, and CSA C. No UL: UL00, UL 0000 (CSA NRTL/C) CE: EMC directive EN compliance, Class A Table * EN compliance EN 000 compliance EN 000 compliance EN 0 Class A Group Low voltage directive: EN 00, EN 0000 Installation category II * Pollution degree * Measurement category O (other) EMC Regulatory Arrangement in Australia and New Zealand (RCM): EN 0 Class A, Group KC marking: Electromagnetic wave interference prevention standard, electromagnetic wave protection standard compliance * Installation category (overvoltage category) II: Describes a number which defines a transient overvoltage condition. Implies the regulation for impulse withstand voltage. II applies to electrical equipment which is supplied from the fixed installation like a distribution board. = All Rights Reserved. Copyright, Yokogawa Electric Corporation GS 77J0A070E Feb. 0, 0700
4 * Pollution degree : Describes the degree to which a solid, liquid, or gas which deteriorates dielectric strength or surface resistivity is adhering. applies to normal indoor atmosphere. Normally, only nonconductive pollution occurs. * The instrument continues to operate at a measurement accuracy of within ±0% of the range during testing. However, if optional code /C0 or /FB is specified, the conformity to the safety and EMC standards is excluded. Environment Standard RoHS Directive: EN 08 (However, when option code /C0 or /FB is specified, CE marking is not applicable because the product does not comply with the Safety and EMC standards.) Power and Isolation Power Rated Voltage: 00 to 0 V AC/DC ~ 0/0 Hz to 0 V DC... Power Voltage: 00 to 0 V AC/DC (, 0%) 0/0 Hz or to 0 V DC (±0%) Power Dissipation: V DC. W, 0 V DC. W 00 V AC. VA, 00 V AC 8.8 VA Insulation Resistance: 00 MΩ/00 V DC between input, output, output, power supply and ground mutually. Withstand Voltage: 000 V AC / minute between input, (output, output), power supply, and ground mutually. 000 V AC / minute between output and output. Terminal Arrangement Environmental Conditions Temperature: 0 to C ( C or less for sidebyside close installation*) * If the previous model (style S.xx earlier) is installed together, the ambient temperature is 0 to 0 C. Humidity: to 0 % RH (no condensation) Ambient Condition: Avoid installation in such environments as corrosive gas like sulfide hydrogen, dust, sea breeze and direct sunlight Installation altitude 000m or less above sea level. Magnetic field: 00 A/m or less. Continuous vibration (at to Hz) Half amplitude of mm or less (at to 0 Hz). m/s or less, oct/min for 0 minutes each in the axis directions. Impact: 8 m/s or less, msec, axis times each in directions. Altitude: 000 m or less. Warmup time: At least 0 minutes after power on. Transport and Storage Conditions Ambient temperature: to 70 C Temperature change rate: 0 C per hour or less Ambient humidity: to %RH (no condensation) Mounting and Dimensions Construction: Compact plugin type Material: Modified Polyphenylene Oxide (Case body) Mounting Method: Wall, DIN rail, or dedicated VJ mounting base mountings Connection Method: M screw terminal External Dimension:.x7x. mm (WxHxD) (with socket) Weight: Main unit: 00 g or less, Socket: 0 g or less Standard Accessories Tag Number Label: sheet Terminal No. Signal Output Analog output Output Communication output Output Alarm output (PS) Output () B () ALM () Output () A () 7 8 Output Output N.C. () ALM 0 Output () L N Note : In case of one output type, output is N.C. All Rights Reserved. Copyright, Yokogawa Electric Corporation GS 77J0A070E Feb. 0, 0700
5 Block Diagram to 0 ma PS When using external power supply to 0 ma PS Construction of intrincial safety system using zener barrier PS to 0 ma Handy Terminal or PC (VJ77) R R: 0 Ω power supply processing Insulation Insulation Power supply Output Output 7 Output L 0 N 8 Output Communication output B() Relay Alarm output Alarm Communication A() Relay (common) Alarm When output is communication output When output is alarm output External Dimensions Connector for Handy Terminal ø.x Small oval hole Unit : mm Alarm lamp (Note ) DIN rail (0). () M screw. 7 Note : Only when output is alarm output All Rights Reserved. Copyright, Yokogawa Electric Corporation GS 77J0A070E Feb. 0, 0700
General Specifications
General Specifications GS 77J01Q08-01E Model VJQ8 Pulse to Analog Converter (Multi-function) (Isolated Single-output and Isolated Dual-output Types) General This plug-in type pulse to analog converter
More informationGeneral Specifications
General Specifications GS 77J04H0-0E Model MH Isolator (Free Range Type) General The MH is a plug-in type isolator that converts DC current or DC voltage signals into isolated DC current or DC voltage
More informationGeneral Specifications
General Specifications GS J0X-0E Model MXT Universal Computing Unit (-input, Isolated -output Type) General This plug-in type universal computing unit receives DC current or DC voltage signals, applies
More informationGeneral Specifications
General Specifications MODEL UT50L Limit Controller GS 5DD-0E Overview The UT50L is an FM approved limit controller that can be configured either as a high limit or as a low limit controller by a user.
More informationGeneral Specifications
General Specifications GS 05F01D01E MODEL UM351 Digital Indicator with Alarms with Active Color PV Display General Model UM351 Digital Indicator with Alarms is a precision alarm instrument provided with
More informationGeneral Specifications
General Specifications GS 0F01D0E Model UM1 Digital Indicator with Alarms with Active Color PV Display General Model UM1 Digital Indicator with Alarms is a precision 1/8 DIN alarm instrument provided with
More informationGeneral Specifications
General Specifications GS 0F01D01E Model UM1 Digital Indicator with Alarms with Active Color PV Display General Model UM1 Digital Indicator with Alarms is a precision alarm instrument provided with universal
More informationGeneral Specifications
General Specifications Model UT, UT Temperature Controller GS CE-E GENERAL UT series temperature controllers provide only the functions and size you require for your application. /6 DIN sizes is available.
More informationGeneral Specifications
General Specifications Model UM350 Digital Indicator with Alarms GS 05F0D00E General Model UM350 Digital Indicator with Alarms is a precision alarm instrument with universal input. For excellent monitoring
More informationGeneral Specifications
General Specifications GS J0U0-0E Model MU Universal Temperature Converter (Free Range Type) General The MU is a plug-in type universal temperature converter that converts input signal (thermocouple, RTD
More informationGeneral Specifications
General Specifications Model UM330 Digital Indicator with Alarms GS 05F0D00E General Model UM330 Digital Indicator with Alarms is a precision alarm instrument with universal input /8DIN. For excellent
More informationGeneral Specifications
General Specifications MODEL UM0 Digital Indicator with Alarms GS 0F0D00E General Model UM0 Digital Indicator with Alarms is a precision alarm instrument with universal input /8DIN. For excellent monitoring
More informationUser s Manual. Model MA5 Distributor (Free Range Type) CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT MODEL AND SUFFIX CODES
User s Manual Model MA5 Distributor (Free Range Type) IM 77J04A05-0E Network Solutions Business Division 2-9-32, Naka-cho Musashino-shi, Tokyo 80-8750 Japan Phone 8-422-52-779 Facsimile 8-422-52-6793 Please
More informationGeneral Specifications
General Specifications GS J08X0-0E FX Series Computing Units (mv Input/Variable Software Type) Moving Average Unit, Dead Time Unit, Velocity Unit, First Order Lug Unit, First Order Lead Unit, Velocity
More informationGeneral Specifications
General Specifications GS J08X0-0E FX Series Computing Units (Variable Software Type) Moving Average Unit, Dead Time Unit, Velocity Unit, First Order Lug Unit, First Order Lead Unit, Velocity Limiter,
More informationMODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value.
Super-mini Signal Conditioners Mini-M Series FREQUENCY TRANSMITTER (PC programmable) Functions & Features Converts the output from a pulse-type transducer into a standard process signal PC programmable
More informationGeneral Specifications
General Specifications GS 77J09X01-01E WX1 Series Computing Units (Variable Software Type) Moving Average Unit, Dead Time Unit, Velocity Unit, First Order Lug Unit, First Order Lead Unit, Velocity Limiter,
More informationGeneral Specifications
General Specifications GS J0X02-01E WX2 Series Computing Units (Variable/Fixed Software Type) Moving Average Unit, Dead Time Unit, Velocity Unit, First Order Lug Unit, First Order Lead Unit, Velocity Limiter,
More informationSHIMADEN DIGITAL INDICATORS
Shimaden, Temperature and Humidity Control Specialists C %RH Series SD16A & SHIMADEN DIGITAL INDICATORS approved,ul applied BASIC FEATURES compliance DIN Size 48 x 96 mm ±.3% High Accuracy Indication Large
More informationGeneral Specifications
General Specifications GS J08X0-0E FX Series Computing Units (Variable/Fixed Software Type) Moving Average Unit, Dead Time Unit, Velocity Unit, First Order Lug Unit, First Order Lead Unit, Velocity Limiter,
More informationMODEL: M2XU MODEL: M2XU [1][2] [3][4]
Super-mini Signal Conditioners Mini-M Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Accepts direct inputs from various sensors and provides a standard process signal I/O types and
More informationGeneral Specifications
General Specifications GS 05P01F31-01EN UT32A Digital Indicating Controller (Entry model) Functional Enhancement Overview The UT32A entry model digital indicating controller is an easily configurable single-loop
More informationMODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]
MODEL: MMNV Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels
More informationGeneral Specifications
General Specifications UM33A Digital Indicator with Alarms [Style: S9] Overview The UM33A digital indicator with Alarms employ an easy-to-read, 14-segment large color LCD display, along with navigation
More informationSHIMADEN DIGITAL INDICATOR
Shimaden, Temperature and Humidity Control Specialists C %RH Series SD24 & KR16A SHIMADEN DIGITAL INDICATOR BASIC FEATURES ohigh Accuracy ±0.1% FS+1 digit o1/1000ºc Resolution Indication Possible (Pt input
More informationMODEL: M2VF MODEL: M2VF [1][2] [3][4]
Super-mini Signal Conditioners Mini-M Series SIGNAL TRANSMITTER (high speed response) Functions & Features Converts DC input from a sensor into a standard process signal Isolation between input and output
More informationSHIMADEN DIGITAL INDICATORS
Shimaden, Temperature and Humidity Control Specialists C %RH Series SD16 & SHIMADEN DIGITAL INDICATORS & NRTL /C approved BASIC FEATURES DIN Size 48 x 96 mm ±.3% High Accuracy Indication Large 2 mm bright
More informationMODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]
Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels CE marking
More informationMODEL: AS4V. Plug-in Signal Conditioners M-UNIT
Plug-in Signal Conditioners M-UNIT DC ALARM (dual or quad alarm trip; field-configurable) Functions & Features Provides relay outputs at preset DC input levels Quad or dual trip Setting and display in
More informationMODEL: DA3. Plug-in Signal Conditioners M-UNIT
Plug-in Signal Conditioners M-UNIT D/A CONVERTER (16-bit resolution) Functions & Features Converts parallel digital signal into a DC output BCD, binary, offset binary, two's complement, reflected binary
More informationHigh Performance Process & Temperature Controllers
C22 C62 C82 C83 High Performance Process & Temperature Controllers C72 C42 R22 01. Multi Color LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. 200 msec Sampling Rate 04. True Universal
More informationMODEL: W2TS. Mini-MW Series
Space-saving Dual Output Signal Conditioners Mini-MW Series THERMOCOUPLE TRANSMITTER Functions & Features Accepts direct input from a thermocouple and provides a standard process signal 5-segment linearization
More informationUser s Manual. Model MS5 Potentiometer Converter (Free Range Type) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT
User s Manual Model MS5 Potentiometer Converter (Free Range Type) IM 77J04S05-0E Network Solutions Business Division 2-9-32, Naka-cho Musashino-shi, Tokyo 80-8750 Japan Phone: +8-422-52-779 Facsimile:
More informationMODEL: M2DYS SEN TRONIC AG
Super-mini Signal Conditioners Mini-M Series CURRENT LOOP SUPPLY Functions & Features Powers a 20 ma DC current loop Short circuit protection Applicable to smart transmitters CE marking UL approval Typical
More informationUser s Manual. Model MXS Universal Computing Unit (1-input, Isolated 2-output Type) MODEL AND SUFFIX CODES
User s Manual Model MXS Universal Computing Unit (1-input, Isolated 2-output Type) IM 77J04X11-01E Network Solutions Business Division 2-9-32, Naka-cho Musashino-shi, Tokyo 180-8750 Japan Phone: 81-422-52-7179
More informationMODEL: M2SES SEN TRONIC AG [3] OUTPUT
Super-mini Signal Conditioners Mini-M Series HIGH/LOW SELECTOR Functions & Features Monitors two DC input signals and transmits an output signal proportional to the higher or lower input CE marking UL
More informationGeneral Specifications
General Specifications GS 04L53B01-01EN GX90XA/GX90XD GX90YD/GX90WD I/O Modules OVERVIEW I/O modules are connected to the GX/GP, Expandable I/O unit, GM main unit, and GM sub unit. A module type is four
More informationRI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters
RI-D440 Three Phase easywire Multifunction DIN Rail Energy Meter Four module DIN rail mounted Energy pulse LED 330mV Input from easywire CTs (or -/1A and -/5A current transformer input with TAS-SCTEWA
More informationMICRO-CONTROLLER X (48 48 mm)
PX series digital temperature controller MICRO-CONTROLLER X ( mm) DATA SHEET PXG PXG is a compact size temperature controller of front panel size mm. To cope with any of versatile uses as a temperature
More informationMODEL: W2DYS SEN TRONIC AG. Mini-MW Series
MODEL: WDYS Space-saving Dual Output Signal Conditioners Mini-MW Series CURRENT LOOP SUPPLY Functions & Features Powers a 0 ma DC current loop Short circuit protection Applicable to smart transmitters
More informationExcellent low-cost Process & Temperature Controllers
C22 C62 C82 C83 Excellent low-cost Process & Temperature Controllers C72 C42 R22 01. High Quality LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. The Fast Sampling Rate in 200
More informationGeneral Specifications
General Specifications Model UT Digital Indicating Controller GS 0D01C0E General Model UT Digital Indicating Controller is an intelligent, microprocessor based digital indicating controller with powerful
More informationMODEL: M6SXU MODEL: M6SXU [1][2] [3][4]
Tension-Clamp Ultra-Slim Signal Conditioners M6S Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection Universal input (mv, V, ma, T/C, RTD and potentiometer)
More information22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection
Relays 22 Technical Data...1 Specifications...2 Model Number Structure - Relays...3 Model Number Selection... 4-5 Electrical Characteristics...6 Accessories...7 Dimensions...8 Instructions...10 Safety
More informationB850 Boiler House Energy Monitor
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationGeneral Specifications
General Specifications GS 05P08D81-01EN UT32A-D/MDL Digital Indicating Controller (Dual-loop, DIN Rail Mounting Type) Functional Enhancement Overview The UT32A-D/MDL controller is a dual-loop controller
More informationMICRO-CONTROLLER X (96 96 mm)
PX series digital temperature controller MICRO-CONTROLLER X ( mm) DATA SHEET PXG PXG is a compact size temperature controller of front panel size mm. To cope with any of versatile uses as a temperature
More informationADAM 4000/4100 Series
ADAM 4000/4100 Series Common Dimensions Communication RS-485 (2-wire) to host Speeds: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps (ADAM-4080, ADAM-4080D only support up to 38400 bps) Max. communication
More informationProtection components
Multifunction protection relays LT-P Environment Conforming to standards IEC 947-4-1, IEC 34-11, IEC 755, VDE 010, VDE 00. &Ãmarking Meets the essential requirements of the Low Voltage equipment (LV) &
More informationModel Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models
Solid-state Power OFF-delay Timer H3DE-H Timers Two delay-time models available. 0.1 to 12 seconds (S Series) 1 to 120 seconds (L Series) Covers wide range of supply voltage. Model Number Structure Model
More informationP5201 Universal Programmable Transmitters with Galvanic Isolation
Transmitters - KB0288-2012/09 P5201 Universal Programmable Transmitters with Galvanic Isolation One type of transmitter for all regular resistance and thermocouple sensors. Linearized output signal 4 to
More informationHawk 3 Digital Panel Meter / Controller
File # E199939 All parameters set from easy to understand front panel access One, two or four 5-amp relays optional Five user-selectable brightness levels 1/8 DIN, shallow depth case, 3.24 RS485 digital
More informationGeneral Specifications
General Specifications MODEL UT0 Digital Indicating Controller GS 0D01C00E General Model UT0 Digital Indicating Controller is an intelligent, microprocessor based digital indicating controller with powerful
More informationModels UT550/UT520 Digital Indicating Controllers User s Manual for Loop Control for Backup
Instruction Manual Models UT550/UT520 Digital Indicating Controllers User s Manual for Loop Control for Backup IM 05D01C02-45E IM 05D01C02-45E 1st Edition Blank Page Introduction Thank you
More information1 INTRODUCTION ORDER CODE / INFORMATION
INTRODUCTION ORDER CODE / INFORMATION 269/269Plus * * * * * * 269/269Plus SV D/O.4 ORDER CODE / INFORMATION Motor management relay Standard version Drawout version Phase CT Ground CT (required for D/O
More informationSHIMADEN PROGRAM CONTROLLER
Shimaden, Temperature and Humidity Control Specialists C %RH SHIMADEN PROGRAM CONTROLLER approved BASIC FEATURES Full multi-input and multi-range performance User selectable Thermocouple, RTD, V, mv and
More informationGeneral Specifications
General Specifications Signal Conditioner Cards OUTLINE Signal Conditioner Cards, which interface to the process, are installed in Signal Conditioner Nests. [Release 6] The signal conditioner cards can
More informationGeneral Specifications
General Specifications EJA530E S-Series Cherry Burrell I Line Sanitary Pressure Transmitter GS 530SCBS-01E The EJA530E S-Series sanitary pressure transmitters combine Yokogawa s EJA-E series in-line pressure
More informationB850 Boiler House Energy Monitor
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationGeneral Specifications
General Specifications GS 05P01C81-41EN UT52A, UT32A Digital Indicating Controller (DIN Rail Mounting and Wireless Communication Type) Overview The UT52A and UT32A controllers are multi-function I/O device
More information- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION
ADVANCED - CONTROLLERS - SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION (ma) OUTPUTS - 4x EVENT OR ALARM OUTPUTS
More informationA6500-UM Universal Measurement Card
Specifications Sheet A6500-UM Universal Measurement Card The A6500-UM Universal Measurement Card is a component of the CSI 6500 ATG machinery protection system. The card is equipped with 2 sensor input
More informationDC1010/DC1020/DC1030/DC1040
05/0 0-10-10-0-EN Page 1 of DC1010/DC1020/DC100/DC1040 DIGITAL CONTROLLERS Specification Overview The DC1000 Series are microprocessorbased controllers designed with a high degree of functionality and
More informationResistance Temperature Device Conversion Module
No.SS2-2330-0350 (Rev. 1) SystempaK (Digital/Single Case) Resistance Temperature Device Conversion Module Model J-SRP 90/95 Introduction The Resistance Temperature Device (RTD) Conversion Module (J-SRP)
More informationPRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID
RI-D140 Three Phase Multifunction DIN Rail Energy Meter (MID Certified) Four module DIN rail mounted Energy pulse LED True RMS measurement Cost effective and accurate Modbus communication -/1A or -/5A
More informationGeneral Specifications
General I/O Adaptors (for N-IO) GS 33J62F30-01EN [Release 6] GENERAL This General (GS) describes the hardware specifications of I/O adaptors that enable extended functions setting for analog digital I/O
More informationGeneral Specifications
General Specifications MODEL 550 Digital Indicating Controller GS 05D0C00E General Model 550 Digital Indicating Controller is an intelligent, microprocessor based digital indicating controller with powerful
More information10-CH Digital Thermometer Module
User's Manual 10-CH Digital Thermometer Module 3rd Edition 3rd Edition Thank you for purchasing the 10-CH Digital Thermometer WE7241 for the PC-based measurement instruments, WE7000. This User s Manual
More informationOperating Manual MU2000K
ZIEHL industrie elektronik GmbH + Co KG Daimlerstr.13, 74523 Schwäbisch Hall, Germany + 49 791 504-0, info@ziehl.de, www.ziehl.de Temperature Relays and MINIKA Mains Monitoring Digital Panelmeters MINIPAN
More informationGeneral Specifications
General Specifications GX90XA/GX90XD/GX90YD/ GX90WD/GX90XP/GX90YA I/O Modules GS 04L53B01-01EN OVERVIEW I/O modules are connected to the GX/GP, Expandable I/O unit, GM main unit, and GM sub unit. A module
More informationModels UT350/UT320 Digital Indicating Controllers
User s Manual Models UT350/UT320 Digital Indicating Controllers User s Manual IM 05D01D02-41E IM 05D01D02-41E 4th Edition Blank Page Introduction i Thank you for purchasing the UT350/UT320
More informationProgrammable AC Current Transducer MT418
Programmable AC Current Transducer MT418 RMS AC current measurements Current auto range measurements up to 12 A Frequency measurement range 16 400 Hz AC or universal wide auiliary power supply range 24
More informationHigh-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals
Accessories Highquality digital indicator for panel mounting Model DI35M, with multifunction input Model DI35D, with two inputs for standard signals WIKA data sheet AC 80.03 Applications Machine building
More informationProcess displays For standard signals, temperature, resistance measurement
Features Inputs: Voltage ±10 V, ±200 V / Current ±20 ma / thermocouples J,K,T,N,Pt100,Pt1000 / resistance measurement / potentiometer Display range can be linearised Two limits output Min, Max functions
More informationMINI MCR-SL-UI-I-LP-NC
2-way isolation amplifier Data sheet 105263_en_02 PHOENIX CONTACT 2013-12-13 1 Description The configurable 2-way isolation amplifiers are used to electrically isolate, convert and filter standard signals.
More informationPhase control Single function phase control relay - 7.5 mm Control of -phase networks: phase sequence, total phase failure Multi-voltage from x 08 to x 480 V Controls its own supply voltage True RMS measurement
More informationOFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category
Safety Relay Unit Four kinds of -mm wide Units are available: A -safety contact model, a -safety contact model, and models with safety contacts and OFF-delay safety contacts. Also available are 7.-mm wide
More informationGeneral Specifications
General Specifications GS 05D01D01E Model UT351 Digital Indicating Controller with Active Color PV Display General Model UT351 Digital Indicating Controller is a highly accurate 1/4 DIN controller, provided
More informationGeneral Specifications
General Specifications Model UP350 Program Controller GS 05E0D00E General Model UP350 program controller is a precision controller, featuring two program profiles and universal input/output. For easy operation,
More informationVoltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages For the monitoring of voltages in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
More informationJUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes
Data sheet 902931 Page 1/10 JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes For processing physical measurands of the JUMO Wtrans series RS485 interface with Modbus protocol
More informationModel UP350 Program Controller
User s Manual Model UP350 Program Controller User s Manual IM 05E01D02-41E IM 05E01D02-41E 2nd Edition Blank Page Introduction i Thank you for purchasing the UP350 program controller. How to
More informationMODEL: DAST-20. Telemetering System
MODEL: DAST-0 Telemetering System TELEMETERING SYSTEM Functions & Features Small-scale telemetering system Lightning arrester protecting telephone circuit standard Approved of Technical Requirements Compliance
More informationDSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters
Industrial Loop Isolators and Transmitters DSCL,, SCTP DSCL,, SCTP Industrial Loop Isolators and Transmitters Description Dataforth s DSCL,, and SCTP series of products is a complete family of loop and
More informationDIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure
New Product News Measuring & Monitoring Relays K8AK/K8DS Series DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays Compact 22.5 mm and 17.5 mm housings Resistant to high-frequency
More informationCompoBus/D-type Digital Controller
CompoBus/D-type Digital Controller Digital Controller for the CompoBus/D and Conforming the DeviceNet Conforms the DeviceNet and connects a Programmable Controller without any programming. High performance
More informationGeneral Specifications
General Specifications Signal Conditioner Cards GS 33K50H80-50E OUTLINE Signal Conditioner Cards, which interface to the process, are installed in Signal Conditioner Nests. [Release 5] The signal conditioner
More informationRelays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.
RFV Key features: Compact and EN compliant RFV force guided relays Force guided contact mechanism (EN00 Type A TÜV approved) Contact configuration -pole (NO-NC, 3NO-NC) 6-pole (NO-NC, NO-NC, 3NO-3NC) Built-in
More informationDigital Panel Meters DC/AC Current and Voltage Indicator/Controller Type LDM40
Digital Panel Meters Current and Voltage Indicator/Controller Type LDM40 Multi-input instrument 4-DGT LED 0.1% RDG basic accuracy TRMS AC current and voltage measurements AC/DC current measurements: selectable
More informationPower Meter Series PM3200 Functions and characteristics
Functions and characteristics PB108433 This PowerLogic Power meter offers basic to advanced measurement capabilities. With compact size and DIN rail mounting, the PM3200 allows mains and feeders monitoring
More informationProgrammable AC Voltage Transducer MT416
Programmable AC Voltage Transducer MT416 RMS AC voltage or frequency measurements Voltage auto measurements up to 600 V L-N Frequency measurement 16 400 Hz AC or universal wide auiliary power 24 300 Vdc,
More informationPCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US
PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load Compact: 20 15 10 mm (L W H). Low power consumption: 200 mw. Flux protection or fully sealed construction available. Unique
More informationCurrent monitoring relays CM-SRS.2 for single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.2 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
More informationCurrent monitoring relays CM-SRS.1 for single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.1 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
More informationDigital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE
Digital Panel Meter K3TE Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input Compact DIN-size (96 x 48 (W x H)) body. Mounting thickness of only 3.5 mm required. Highly visible display with
More informationSRX. General Description. Features. Module type High-speed Digital Controller SRX. Multi-Zone Space-Saving. High-speed Feedback Control
SX General Description The SX is a module type digital controller with a super high speed sampling of control updating cycle time of ms (0.0 sec). Dual loop control can be performed with a single compact
More informationConverter. Specifications/Instructions. General. Features. Specifications. Dimensions AB-6484
AB6484 Specifications/Instructions Converter General Model RYY792X series of s offer compact, spacesaving, easy installation with its plugin structure. Each model is modularized for a particular function.
More informationJUMO Wtrans Receiver with Wireless Data Transmission
Data Sheet 902931 Page 1/10 JUMO Wtrans Receiver with Wireless Data Transmission k For measuring temperature, pressure, potentiometer, and voltage. k Interface RS485 with Modbus protocol k Wireless measured
More informationSignet 9950 Dual Channel Transmitter
Signet 9950 Dual Channel Transmitter Member of the SmartPro Family of Instruments Features One instrument for multiple sensor types Multiple language support for (Gen 2a) or later in Simplified Chinese,
More information[3] MOUNTING DIRECTION
Bargraph Indicators N Series BARGRAPH INDICATOR Functions & Features Displays two process variables in dual graphic bargraphs of LED segments Single and dual bargraphs IP front cover plate is easily replaced
More information