General Specifications

Size: px
Start display at page:

Download "General Specifications"

Transcription

1 General Specifications Model UT Digital Indicating Controller GS 0D01C0E General Model UT Digital Indicating Controller is an intelligent, microprocessor based digital indicating controller with powerful control capability and the userfriendly large numerical display. The UT features as standard many functions which are necessary for various control applications, and all of these functions such as control function, control computation function, signal computation function, etc. can be configured by using the keys on the front panel. The instrument has eight types of control strategies and also an overshoot suppressing function "SUPER" and a hunting suppressing function "SUPER " as well as an autotuning function built in as standard. Panel size is small, mm (width) mm (height), and designed for saving space. UT UTE E indicates the model with expanded functions. Main Features High resolution display of digits. Since LEDs of mm height are used for displaying measured values, the display is clearly read. The front panel size is mm (width) mm (height) and the depth is 0 mm, designed for saving space. Eight types of control function, including singleloop control, cascade control, loop control with autoselector, and loop control with hold function, enabling the operator to start control operation immediately after simply entering the settings. Parameter can be easily set using a personal computer. ("Parameter setting tool (model LL0)" sold separately is required.) Universal input and output enables users to set or change freely the type of measured inputs, measurement input range, type of control output, etc. from the front panel. Contact inputs (up to points) and contact outputs (up to points) Note can be employed and functions can be assigned to each contact (The maximum number of points varies depending on the specification code.) Note: See the Hardware Specifications and Contact Outputs described later. Various communication function are provided. Communication is possible with personal computer, programable logic controller, and other controllers. Functional Specifications Control Functions UT Mode The following types of basic control structure can be set as the UT mode by the user. Singleloop control (UT mode 1): The most simple and basic control function. Cascade primaryloop control (UT mode ): Output tracking function and cascade control logic are provided. Suitable for primaryloop cascade control. Cascade secondaryloop control (UT mode ): Setpoint output and the cascade control logic are provided. Suitable for secondaryloop cascade control. Cascade control (UT mode ): Dual control function for cascade control is available in a single instrument. Loop control for backup (UT mode ): Output tracking function is provided to back up another control instrument. The local and remote control outputs are switched by a contact input. Loop control with switching (UT mode ): Two measured inputs are switched for control depending on the status of contact input or measured input. Loop control with autoselector (UT mode ): Two measured inputs are automatically selected for control with a high, low, or average, or temperaturedifference value selector. Loop control with hold function (UT mode ): This control holds a input and a control output if an external sensor is switched. Control Computation Functions In each UT mode, the following control computation functions can be selected. Continuous PID control, Timeproportional PID control, and Relay ON/OFF control. Target setpoint and PID parameters: Maximum eight sets of target setpoint and PID parameters can be set. These eight sets can be set for both the main and slave loops in cascade control. Zone PID selection: Dividing measuring range into maximum zones by maximum reference points, PID parameter set switching in up to measured input zones. Autotuning: Available as standard. Possible to activate autotuning for both main and slave loops for cascade control. GS 0D01C0E Copyright Feb. 00 (YK) nd Edition Jul. 0 (YK)

2 Preset output function: When the instrument is in STOP mode, measured input is burntout, or an abnormality is found in an input circuit, a preset value is output as a control output. "SUPER" function: Overshoots generated by abrupt changes in the target setpoint or by disturbances can be suppressed. "SUPER " function: The function stabilizes the state of control that is unstable due to hunting, etc. without requiring any change in PID constants, when the load and/or gain varies greatly, or when there is a difference between the characteristics of temperature zones. Control cycle time Each cycle time can be selected under the following conditions.: 0 ms: Available for model code UT00, when UT mode is set to Singleloop control and the following functions are not used: "SUPER" function, "SUPER " function, input computation, setpoint rateofchange limiter, MV output rateofchange limiter, deviation alarm, sensor grounding alarm, fault diagnosis alarm, and FAIL output. 0 ms: Available when UT mode is not cascade control. 0 ms: Available when UT mode is cascade control. (Set value on shipped from the factory: 0 ms) Operation Mode Switching (Note: Communication enables all the following mode switching to be executed.) AUTO/MANU switching: Bumpless switching between automatic operation mode and manual control mode is available by using the front keys or contact input. The contact input has priority over front key input or switching by communication. The contact input is invalid for Cascade secondaryloop control or Cascade control. RUN/STOP switching: Switching by contact input (bumpless for switching from STOP to RUN). The contact input has priority over switching by communication. In RUN mode, control computation is activated. In STOP mode, control computation ceases and a preset value is output as a control output while other functions operate normally. OTE/LOC switching: Switching between remote setpoint and local setpoint by instrument operation or contact input. The contact input has priority over instrument operation or switching by communication. For remote to local switching, either bumpless tracking (employing the remote setpoint on switching as the local setpoint) or without tracking (directly switching the local setpoint) can be specified. CADE/AUTO/MANU switching: Switching by instrument operation or contact input. The contact input has priority over instrument operation or switching by communication. Valid for Cascade secondaryloop control or Cascade control. Output tracking ON/OFF switching: Provided for Cascade primaryloop control or Loop control for backup. External tracking signal and internal control output are switched by the contact input. The contact input has priority over the switching by communication. Control Parameters Setting Range Proportional band: 0.1 to.% Integral time: 1 to,000 s, or OFF (for Manual reset) Derivative time: 1 to,000 s, or OFF ON/OFF control hysteresis: 0.0 to 0.0% of measured input range width Preset output:.0 to.0% of the output (0 ma or less cannot be output) Output limiter: Setting range:.0 to.0% for both high and low limits However, "low limit setpoint < high limit setpoint" must be satisfied. Shutdown function: When manual control is carried out with to ma output, control output can be output down to about 0 ma (shutdown is specified for.0% or less). Rateofchange limiter for output: OFF or 0.1 to 0.0%/s Configuration of Input/Output Signal Measured Input Computations Input processing, Square root extraction (voltage input only, Input low cut 0.0 to.0%), Tensegment linearizer function, TenSegment bias, Bias addition (0.0 to 0.0%), and First order lag filter (OFF, time constant 1 to 0 s) Auxiliary Input Computations (Applied to remote setting input only) Input processing, Square root extraction (Input low cut 0.0 to.0%), Bias addition (0.0 to 0.0%), Ratio multiplication (0.001 to.), and First order lag filter (OFF, time constant 1 to 0 s) Alarm Functions Alarm types: high limit, low limit, Deviation high limit, Deviation low limit, Deenergized on deviation high limit, Deenergized on deviation low limit, Deviation high and low limits, High and low limits within deviation, Deenergized on high limit, Deenergized on low limit, SP high limit, SP low limit, Output high limit, Output low limit. Alarm setting range: /SP alarm: 0 to 0% of measured input range Deviation alarm: 0 to 0% of measured input range span Output alarm:.0 to.0% of output value Alarm hysteresis: 0.0 to 0.0% of measured input range span Delay timer: 0.00 to. (minute, second) An alarm is output when the delay timer expires after the alarm setpoint is reached. Setting for each alarm is possible. All Rights Reserved. Copyright 00, Yokogawa Electric Corporation GS 0D01C0E nd Edition Jul., 000

3 Standby action: Standby action can be set to make / deviation alarm OFF during startup or after SP change until SP reaches the normal region. Timer function (stabilization of control status notification event) (Alarm 1 only): This function sets the alarm 1 output to ON when a preset time (timer setting) elapses after a has reached to the control target setpoint hysteresis band to notify that processing has completed. Restarted in RUN/STOP or SP switching. Other alarm actions: Sensor grounding alarm: Detects sensor deterioration and outputs an alarm. Faultdiagnosis alarm: For input burnout, A/D conversion error, or thermocouple reference junction compensation error. FAIL output: Abnormality in software or hardware. Number of alarm settings: The alarm status can be read via communication in addition to output as the above alarm output. Alarm output points (see also the item "Contact Outputs") Number of contact (relay) outputs: (standard) or (if a control output relay is used for the alarm output relay.) Any of alarm, deviation alarm, SP alarm, output alarm, Faultdiagnosis alarm, sensor grounding alarm and FAIL output can be assigned to contacts for the above number of outputs. However, the timer delay alarm can be assigned to the alarm 1 output only. Also, the alarm only can be assigned to the control output relay (if a relay is not used for control output). Display and Operation Functions Display is displayed on the digit display. 1 and are displayed by switching them in cascade control. The number of display digits is or. For thermocouple or RTD, data below the decimal point can be set not to display. The display range is 1 to 000 and the display span is 000 or less. [.00 appearing in the product photograph on page 1 cannot actually be displayed.] Setpoint Display A parameter name is displayed in the digit display and data in the digit display. There are four kinds of displays : operating display, operating parameter setting display, setup parameter setting display and SELECT display. Operating display: Data necessary for operations, such as setpoint or control output, are displayed depending on the UT mode. Operating parameters setting display: The Operating parameters, which are mainly changed during operation, such as PID constant, are displayed. Setup parameters setting display: The Setup parameters to configure the functions of the instrument before starting operation are displayed. UT model is to be set in this display. SELECT display: Up to five displays which are frequently accessed can be selected from the Operating parameters setting display and Setup parameters setting display to be displayed in the SELECT display. Status Lamps Alarm indicating lamp: Four lamps, 1,,, and Operation mode indicating lamp: (remote operation), MAN (manual mode operation), (cascade operation), and LP (cascade secondaryloop control) Operation Keys, keys: Increases or decreases setpoints and other parameters displayed in the setpoint display. key: Used for setting or change set data, switching the displayed contents, and switching operation modes except for. key: Operation mode switching (Auto/Man) Security Function Keylock by parameters setting and prohibiting operation are available by a password Measured value () display unit Displays and error codes when errors are detected. Data display unit Displays setpoints (SP), output values, valve opening,or parameters. Communication port for light loader Parameters are set via communication from a personal computer. Status lamps Cascade operation() and remote operation() Manual operation (MAN) Lit for secondary parameter indication (LP) Alarm indicating lamps Displays alarms (1,,, or ). Operation keys Increase/decrease of the setting data (, ) Screen switching/parameter selection/entry of set data () Auto/manual operation mode selection () All Rights Reserved. Copyright 00, Yokogawa Electric Corporation GS 0D01C0E nd Edition Jul., 000

4 <<Contents>> <<Index>> Communication Functions (For optional function code only) This controller has four types of communication protocol with one communication interface. Communication is possible with personal computer, programmable logic controller, and other controllers. Communication Protocol Computer link communication: Communication protocol with a personal computer Ladder communication: Communication protocol with the ladder program on some programmable logic controllers. Coordinated operation: Protocol for coordinated operation with more than one GREEN SERIES controller. The UT controller can be connected as a master or slave station. MODBUS communication: Communication protocol with a personal computer, or PLC. RS Communication Interface The RS communication interface (conforms to EIA RS) can be used for personal computer link, ladder communication, MODBUS communication or for coordinated operation. Maximum number of connectable controllers: GREEN SERIES controller 1 Maximum communication distance: 00 m Communication method: Twowire halfduplex or fourwire halfduplex, startstop synchronization, and nonprocedural Communication rate: 00, 00, 00, 00, or 00 bps Examples of Communication System Configuration Diagram (1) Personal computer link communication/ MODBUS communication Personal computer () Ladder communication MELSECA Programmable logic controller UT0, UT Digital indicating controller () Coordinated operation UP0, UP0 Program controller or UT0, UT0, UT Digital indicating controller UT0, UT Digital indicating controller UT0, UT Digital indicating controller All Rights Reserved. Copyright 00, Yokogawa Electric Corporation GS 0D01C0E nd Edition Jul., 000

5 Hardware Specifications Input/Output Signal Specifications Measured Input Signal Number of input points: 1 Type of input, measurement range, and measurement accuracy: The type of input and measurement range can be specified from the input range code shown in the table below. Sampling period: 0, 0, 0 or 00 ms (selectable) Burnout detection: Activated for thermocouple (TC) input, RTD input, or standard signal of 0. to V DC or 1 to V DC. Possible to specify a travel of upscale, downscale, or off. For standard signal input (see the table below), set to burn out at 0.1 V or less. Input bias current: 0.0 µa (for TC or RTD bterminal) Measurement current(rtd): about 0. ma Input resistance: 1 MΩ or more for TC or mv input About 1 MΩ for DC voltage input Allowable signal source resistance: 0 Ω or less for TC or mv input Signal source resistance effect 0.1 µv/ω or less kω or less for DC voltage input Signal source resistance effect Approx. 0.01%/0 Ω Allowable leadwire resistance (for RTD input): Maximum 0 Ω/one wire (Lead resistances of three wires must be equal.) However, it must be Ω/one wire for the range of 0.0 to 0.0 C. Effect of wiring resistance: ±0.1 C/ Ω Allowable input voltage: ± V DC for TC/mV/RTD input ± V DC for DC voltage input Noise rejection ratio: Normal mode 0 db (0/0 Hz) or more mode 0 db (0/0 Hz) or more Reference junction compensation error: ±1.0 C ( to C), ±1. C (0 to C and to 0 C) Applicable standards: JIS, IEC, and DIN (ITS0) for TC and RTD Input type Input range Instrument Instrument code range ( C) range ( F) Instrument accuracy *1 Unspecified (When shipped from the factory) OFF Set the data item input type IN 1 to the OFF option to leave the input type undefined. Thermocouple K to 0.0 C 0.0 to 00.0 C 0.0 to 00.0 C 0.0 to 00.0 F 0.0 to.0 F 0.0 to 00.0 F ±0.1% ±1 digit of instrument range at 0 C or more ±0.% ±1 digit of instrument range at less than 0 C However, ±% ±1 digit of instrument range for type K at temperatures less than 0 C. J 0.0 to 00.0 C 0.0 to.0 F However, ±1% ± 1 digit of instrument range for type T at temperatures less than 0 C. T 0.0 to 00.0 C 0.0 to 0.0 F 0.0 to 00.0 C 0.0 to 0.0 F B 0.0 to 00.0 C to 0 F ±0.% ±1 digit of instrument range at 00 C or more ±% ±1 digit of instrument range at less than 00 C S R 0.0 to 00.0 C 0.0 to 00.0 C to 0 F to 0 F ±0.% ± 1 digit of instrument range N 0.0 to 00.0 C 0.0 to 00.0 F ±0.1% ± 1 digit of instrument range ±0.% ±1 digit of instrument range for temperature at less than 0 C E L (DIN) U (DIN) W (DIN) Platinel to 00.0 C 0.0 to 00.0 C 0.0 to 00.0 C 0.0 to 00.0 C 0.0 to.0 C 0.0 to 0.0 C 0.0 to 00.0 F 0.0 to 00.0 F 0.0 to 0.0 F 0.0 to 00.0 F to 0 F.0 to 00.0 F ±0.1% ±1 digit of instrument range at 0 C or more ±0.% ±1 digit of instrument range at less than 0 C However, ±1.% ±1 digit of instrument range for type E at temperature less than 0 C. ±0.% ±1 digit of instrument range ±0.1% ± 1 digit of instrument range PR0 0.0 to 0.0 C to 00 F ±0.% ±1 digit of instrument range at 00 C or more Accuracy not guaranteed for temperature less than 00 C RTD WReWRe JPt0 Pt to 00.0 C 0.0 to 00.0 C 0.00 to 0.00 C 0.0 to 0.0 C 0.0 to 00.0 C 0.00 to 0.00 C to 00 F 0.0 to 00.0 F 0.0 to 0.0 F 0.0 to 0.0 F 0.0 to 00.0 F 0.0 to 0.0 F ±0.% ± 1 digit of instrument range ±0.1% ± 1 digit of instrument range (Note 1) (Note ) ±0.% ± 1 digit of instrument range (Note 1) ±0.1% ± 1 digit of instrument range (Note 1) (Note ) ±0.% ± 1 digit of instrument range (Note 1) Standard 0. to V to.000 V Display range ±0.1% ± 1 digit of instrument range signal 1 to V to.000 V 1 to to V 0 Display span 000 or to.000 V less (Decimal point DC voltage 0 to V to.00 V position changeable) to mv 0 to0mv.00 to.00 mv 0.0 to 0.0 mv Note 1: The accuracy is ±0. C of instrument range ±1 digit for a temperature range from 0 to 0 C. Note : The accuracy is ±0. C of instrument range ±1 digit for a temperature range from 0 to 0 C. *1: Performance in the standard operating conditions (at ± C, ±% RH, and 0/0Hz power frequency) All Rights Reserved. Copyright 00, Yokogawa Electric Corporation GS 0D01C0E nd Edition Jul., 000

6 Auxiliary Analog Input Signal (UT or only) Functions: Remote setting input, tracking input, cascade control secondaryloop input, etc. Input type: Settable within the range of voltage input 0 to V DC, 0 to V DC, 0. to.0 V DC or 1 to V DC. Number of inputs: 1 point Sampling period: 0, 0 or 00 ms Auxiliary analog input period is linked with sampling period. (when input period is 0ms, auxiliary analog input period is 0ms) Input resistance: Approx. 1 MΩ Input accuracy: ±0.% ± 1 digit of input span for 0 to V DC input ±0.% ± 1 digit of input span for 0 to V DC input ±0.% ± 1 digit of input span for 0. to.0 V DC range ±0.% ± 1 digit of input span for 1 to V DC range Performance in the standard operating conditions (at ± C, ±% RH, and 0/ 0Hz power frequency) Retransmission Output Any of the, target setpoint or control output is output. Or this can be used for V DC loop power supply. Number of output points: 1 or Output signal: to ma DC, 0 to ma DC, to ma DC or to 0 ma DC (0 ma or less cannot be output) Load resistance: 00 Ω or less Output accuracy: ±0.1% of span (±% for 1 ma or less) Performance in the standard operating conditions (at ± C, ±% RH, and 0/ 0Hz power frequency) When using for V DC loop power supply: Supply voltage. to.0 V DC, maximum supply current about 1 ma (with the protection circuit at field shortcircuit) Control Outputs Select the control output from the following output types depending on the product model and UT mode. Current output Number of output points: 1 (switchable to voltage pulse output) Output signal: to ma DC, 0 to ma DC, to ma DC or to 0 ma DC (0 ma or less cannot be output) Load resistance: 00 Ω or less Output accuracy: ±0.1% of span (±% for 1 ma or less) Performance in the standard operating conditions (at ± C, ±% RH, and 0/ 0Hz power frequency) Voltage pulse output Number of output points: 1 (switchable to current output) Output signal: ON voltage V DC or more (load resistance 00 Ω or more; current on shortcircuiting about ma) OFF voltage 0.1 V DC or less Resolution: ms or 0.1% of output value, whichever is greater Relay contact output Number of output points: 1 Output signal: At three of NC, NO, and Contact rating: 0 V AC, A or V DC, A (resistive load) Resolution: ms or 0.1% of output value, whichever is greater Contact Inputs Usage: Target setpoint switching, C/ mode switching, OTE/LOC switching, RUN/STOP switching, or Measured input switching Number of input points: Varies with optional codes (as shown below): UT 0: points UT : points UT : points Input type: Nonvoltage contact input or transistor open collector input Input contact rating: V DC, ma or more ON/OFF detection: For nonvoltage contact input, On.. contact resistance 1 kω or less; Off.. contact resistance kω or more For transistor contact input, On.. V or less; Off.. leak current 0 µa or less Minimum retention time for status detection: input sampling period All Rights Reserved. Copyright 00, Yokogawa Electric Corporation GS 0D01C0E nd Edition Jul., 000

7 Contact Outputs Usage: Alarm output, FAIL output Number of output points: (relay output) However, when a relay is not used for control output, the relay for control output can be used for the alarm. For this reason, the number of relay output points can be changed to by adding to the above. Relay contact rating: 0 V AC, 1 A or V DC, 1 A Display Specifications Measured value () display: digit sevensegment red color LED display; height of letters mm Data display: digits digits, sevensegment red color LED display; height of letters. mm Status indicating lamps: LEDs Conformance to Safety and EMC Standards Safety:Compliant with IEC/EN1: 01, approved by CSA, approved by UL0. Installation category : CAT. II (IEC/EN, CSA) Pollution degree : (IEC/ EN, CSA) Measurement category : I (CAT. I : IEC/ EN) Rated measurement input voltage : V DC max.(across ), 0V AC max.(across ground) Rated transient overvoltage : 00V (Note) Note : It is a value on the safety standard which is assumed by IEC/EN1 in measurement category I, and is not the value which guarantees an apparatus performance. EMC standards:complies with EN During test, the controller continues to operate with the measurement accuracy within ±% of the range. Construction, Installation, and Wiring Construction: Dustproof and Dripproof front panel conforming to IP. For sidebyside close installation, controller loses its dustproof and dripproof protection. Material of the body: ABS resin and polycarbonate Case color: Black Weight: Approx. 1 kg or less External dimensions: W H 0D (from the panel face) (mm) Mounting: Direct panel mounting; mounting bracket, one each for upper and lower mounting Panel cutout dimensions: 0. 0 W 0. 0 H (mm) Mounting attitude: Up to degrees from horizontal; Must not face downward. Wiring connection: With M. screw (for signal, power and grounding wiring) Power Supply and Isolation Power supply: Rated voltage 0 to 0 V AC (±%), 0/0 Hz Power consumption: MAX. VA or less (MAX..0W) Memory backup: Nonvolatile memory. Service life approx times of writings. Withstanding voltage: 00 V AC for 1 min. between primary and secondary 00 V AC for 1 min. between primary and ground terminal 00 V AC for 1 min. between ground terminal and secondary 00 V AC for 1 min. between secondary where primary stand for power and relay output and secondary stand for analog input and output signal, voltage pulse output, and contact input. Isolation resistance: MΩ or more for 00 V DC applied between power and ground terminal Grounding: Class grounding (grounding resistance of 0 Ω or less) Isolation Specifications Measured input terminal : Isolated from other input/output but not isolated from internal circuits. Auxiliary analog input terminal: Isolated from other input/ output and internal circuits. (current output or voltage pulse output) and retransmission output: Not isolated between controll outputs and retransmission output, but isolated from other input/output and internal circuits. Relay contact control output : Isolated from other input/output and internal circuits. Contact input : Not isolated from other contact input, and communication, but isolated from other input/output and internal circuits. Relay contact alarm output : Not isolated from other relay contact alarm outputs, but isolated from other input/output and internal circuits. RS communication : Not isolated from contact input, but isolated from other input/output and internal circuits. Power : Isolated from other input/output and internal circuits. Ground terminal: Isolated from other input/output and internal circuits. All Rights Reserved. Copyright 00, Yokogawa Electric Corporation GS 0D01C0E nd Edition Jul., 000

8 Environmental Conditions Normal operating conditions: Ambient temperature: 0 to 0 C (0 C or less in close mounting sidebyside) However, 0 to C ( C or less in close mounting sidebyside) if two analog current output points and the control relay output are used simultaneously. Temperature change rate limit: C/h or less Ambient humidity: to 0% RH (no condensation) Magnetic field: 00 A/m or less Continuous vibration ( to Hz): Peaktopeak amplitude 1. mm or less Continuous vibration ( to 0 Hz):. m/s or less Short period vibration:. m/s, s or less Shock: m/s or less, 11 ms Installation altitude: 00 m or less above sea level Warmup time: minutes or more Transportation and storage conditions: Temperature: to 0 C Temperature change rate limit: C/h or less Humidity: to % RH (no condensation) Effects of operating conditions Effect of ambient temperature: Whichever is greater, ±1 µv/ C or ±0.01% of F.S./ C for voltage or thermocouple inputs. ±0.0% of F.S./ C for Auxiliary input ±0.0 C/ C (ambient temperature) or less for RTD inputs. ±0.0% of F.S./ C or less for analog outputs. Effect of power supply fluctuation (within rated voltage range): Whichever is greater, ±1 µv/ V or ±0.01% of F.S./ V for analog inputs. ±0.0% of F.S./ V or less for analog outputs. All Rights Reserved. Copyright 00, Yokogawa Electric Corporation GS 0D01C0E nd Edition Jul., 000

9 Function Block Diagram for Singleloop Control input 11, and Remote input Communication 1 and to Contact input INPUT1 INPUT RS DI1 DI DI Input selection Input selection Unit selection Unit selection Analog input range conversion Analog input range conversion Analog input bias Analog input bias Square root extraction Square root extraction Analog input filter Analog input filter seg. linearizer approx./bias Remote setting filter input bias input filter Aux. Input Communication RMS=RSP RMS= Ratio/bias calculation SPN Target setpoints 1 to OTE R/L LOC OTE(ON)/LOC(OFF) switching Target setpoint ramprate function Manual operation Control computation MAN AUTO AUTO(ON)/MAN(OFF) switching Preset output Output limiter STOP S/R RUN STOP(ON)/RUN(OFF) switching OT1 V loop power supply Retransmission output Alarm function RT RT1 OUTPUT1 OUTPUT1 OUTPUT1 OUTPUT DO1 DO DO Current or pulse Relay and 1, and Current* and Current and Alarm 1 Alarm Alarm * Unavailable when control output is current or pulse. Legend Terminal Parameter Function Analog Signal Contact Signal Front Panel Key All Rights Reserved. Copyright 00, Yokogawa Electric Corporation GS 0D01C0E nd Edition Jul., 000

10 Function Block Diagram for Cascade Control Cascade primary input 11, and Communication to Secondary input 1 and Contact inputs INPUT1 RS INPUT DI1 DI DI Input selection Unit selection Analog input range conversion Analog input bias Ratio/bias calculation Input selection Unit selection Analog input range conversion Analog input bias Cascade (OFF ON) Automatic (OFF ON) Manual (OFF ON) Square root extraction Square root extraction Analog input filter Analog input filter seg. linearizer approx./bias seg. linearizer approx./bias input bias input bias input filter input filter RMS= R/L OTE Control computation 1 SPN Primary target setpoint LOC Target setpoint ramprate function SPN Secondary target setpoint If receives the FAIL signal (burnout or A/D converter error) from primary input, operation is switched to AUTO. Output limiter Tracking in AUTO or MAN C/ Tracking signal AUTO, MAN Cascade switching Manual operation Control computation Preset output STOP RUN Output limiter MAN C/, AUTO MAN switching S/R OT V loop power supply Retransmission output Alarm function Control output RT RT1 OUTPUT1 OUTPUT1 OUTPUT1 OUTPUT DO1 DO DO Alarm 1 Alarm Alarm Current or Relay Current*1 Current pulse and 1, and and and *1 Unavailable when control output is current or pulse. Legend Terminal Parameter Function Analog Signal Contact Signal Front Panel Key All Rights Reserved. Copyright 00, Yokogawa Electric Corporation GS 0D01C0E nd Edition Jul., 000

11 11 Function Block Diagram for Loop Control for Backup input 11, and Communication to Tracking signal (Manipulated output from host) 1 and Contact inputs INPUT1 RS INPUT DI1 DI DI Input selection Input selection Unit selection Analog input range conversion Analog input bias Square root extraction Analog input filter seg. linearizer approx./bias Ratio/bias calculation Unit selection Analog input range conversion Analog input bias Analog input filter Tracking switching signal input bias input filter R/L OTE RMS= LOC SPN Target setpoints 1 to Target setpoint ramprate function Manual operation can not be changed when contact input (DI) is set to ON. Control computation MAN AUTO AUTO(ON)/MAN(OFF) switching Tracking (ON) Preset output Output limiter STOP RUN S/R STOP(ON)/RUN(OFF) switching OT1 V loop power supply Retransmission output Alarm function Control output RT RT1 OUTPUT1 OUTPUT1 OUTPUT1 OUTPUT Current or Relay Current *1 Current pulse and 1, and and and DO1 DO DO Alarm 1 Alarm Alarm *1 Unavailable when control output is current or pulse. Legend Terminal Parameter Function Analog Signal Contact Signal Front Panel Key All Rights Reserved. Copyright 00, Yokogawa Electric Corporation GS 0D01C0E nd Edition Jul., 000

12 Function Block Diagram for Loop Control with Switching input 1 input Communication 11, and 1 and to Contact inputs INPUT1 INPUT RS DI1 DI DI Input selection Unit selection Analog input range conversion Analog input bias Square root extraction Analog input filter seg. linearizer approx./bias Input selection Unit selection Analog input range conversion Analog input bias Square root extraction Analog input filter seg. linearizer approx./bias input Switching (Temp. range, Temp. upper limit, or DI) Burnout occurs when the burnout of input 1 or input occurs. input bias input filter Ratio/bias calculation RMS= R/L OTE U1 U U Upper limit Lower limit Operation SPN Target setpoints 1 to LOC input switching (U=) input 1(OFF)/ input (ON) Target setpoint ramprate function Manual operation Control computation MAN AUTO AUTO(ON)/MAN(OFF) switching Preset output Output limiter STOP RUN S/R STOP(ON)/RUN(OFF) switching OT1 V loop power supply Retransmission output Alarm function Control output RT RT1 OUTPUT1 OUTPUT1 OUTPUT1 OUTPUT Current or Relay Current *1 Current pulse and 1, and and and DO1 DO DO Alarm 1 Alarm Alarm *1 Unavailable when control output is current or pulse. Legend Terminal Parameter Function Analog Signal Contact Signal Front Panel Key All Rights Reserved. Copyright 00, Yokogawa Electric Corporation GS 0D01C0E nd Edition Jul., 000

13 RS communication * Wiring can only be carried out input TC input RTD input 11 A b B for controllers with communication functions. Maximum baud rate: 00 bps SDB() SDA() RDB() RDA() SG Note: Select this option from the OT1 parameter. Relay contact output *Time proportional PID relay contact output is configured at factory before shipment. 1 NC NO Contact rating: 0 V AC, A V DC, A (resistance load) Before carrying out wiring, turn off the power to the controller and check that cables to be connected are not alive with a tester or the like because there is a possibility of electric shock. Power supply CAUTION Power supply L 1 N * The functionality of a contact input can be varied by changing the setting of the contact input registration parameter. * Wiring can only be carried out for controllers with remote input. Remote input 1 Specify in a range of V DC, 0 V DC, or 0 V DC. External contact outputs Alarm 1 output DO1 V 1 DI1 Default: V DC UT V DC Power Supply Wired to Sensor in V External contact inputs UT DI1 1 Twowire System Configuration Contact Transistor contact DO Alarm output Relay DI DO Alarm output DI AUTO when DI1=ON MAN when DI1=OFF STOP when DI=ON RUN when DI=OFF input 0..0 V DC signal 0 External resistor (Note) mv/v input * Factoryset to retransmission. Retransmission output 1* * Retransmission output is available only when relay is selected as the type of control output. or 0 ma DC Default: ma DC * Retransmission output 1 is not available if a V DC loop power supply is used. V DC loop power supply*..0 V DC (1 ma DC max.) Retransmission output * Current/voltage pulse output 0mADC, madc 0mADC, madc Voltage pulse ( V) Default: ma DC Receiving ma DC Current Signals with the Controller * Not configured at factory before shipment * When receiving ma DC current signals, set the input type to V DC (setpoint 1 ). 0 Ω ma Note: Connecting a 0 Ω resistor to the is optional. Model: X00 (resistor with M. crimpon terminal lugs) UT Singleloop Control (Factoryset to Singleloop Control), Terminal Arrangements Note: Select this option from the OT1 parameter. Load resistance: 00 Ω or less Default: Unspecified retransmission type Allowable range: 00 V AC ( %) (free voltage) 0/0 Hz shared DI No function DI V V Relay contact rating: 0 V AC, 1 A V DC, 1 A (resistance load) Twowire transmitter DI DI Remote when DI=ON Local when DI=OFF Loop power Note: External Contact Input If the power is turned on when the external contact input is OFF, the mode (SPN, R/L, or ) existing before the power is turned off will be continued. (except for RUN/STOP) supply..0 V DC madc Contact rating: V DC, ma or more * OT1 is a setup parameter. You can change the settings of the parameter OT1 to change the control output type. Note: Connecting a 0 resistor to the is optional. Model: X00 (resistor with M. crimpon terminal lugs) Correspondence between parameter OT1 and control output types OT1= OT1= OT1=1 OT1=0 (factoryset default) Onoff control Relay output (, and ) 1 1 Current output ( and ) Time proportional control Voltage pulse output ( and ) Time proportional control Relay output (, and ) All Rights Reserved. Copyright 00, Yokogawa Electric Corporation GS 0D01C0E nd Edition Jul., 000

14 UT Cascade Control, Terminal Arrangements RS communication * Wiring can only be carried out for controllers with communication functions. Maximum baud rate: 00 bps TC input RTD input 11 A SDB() SDA() b RDB() B RDA() SG Note: Select this option from the OT parameter. Relay contact output *Time proportional PID relay contact output is configured at factory before shipment. 1 NC NO Contact rating: 0 V AC, A V DC, A (resistance load) Before carrying out wiring, turn off the power to the controller and check that cables to be connected are not alive with a tester or the like because there is a possibility of electric shock. Power supply CAUTION Power supply L 1 N * The functionality of a contact input can be varied by changing the setting of the contact input registration parameter. * The functionality of a contact output can be varied by changing the setting of the contact output registration parameter. V 1 DI1 V External contact inputs UT DI1 1 External contact outputs DO1 Alarm 1 output Secondary input Auxiliary input 1 Specify in a range of V DC, 0 V DC, or 0 V DC. Contact Transistor contact DI Default: V DC V DC Power Supply Wired to Sensor in Twowire System Configuration UT DI Cascade switching when DI1 changes to on Automatic switching when DI changes to on DO Alarm output Relay DO Alarm output input 0..0 V DC signal 0 External resistor (Note) DI No function DI V V mv/v input * Factoryset to retransmission. Retransmission output 1* * Retransmission output is available only when relay is selected as the type of control output. or 0 ma DC Default: ma DC * Retransmission output 1 is not available if a V DC loop power supply is used. V DC loop power supply*..0 V DC (1 ma DC max.) Primary input Retransmission output * Current/voltage pulse output 0mADC, madc 0mADC, madc Voltage pulse ( V) Default: ma DC Receiving ma DC Current Signals with the Controller * When receiving ma DC current signals, * Not configured at factory before shipment set the input type to V DC (setpoint 1 ). 0 Ω ma Note: Connecting a 0 Ω resistor to the is optional. Model: X00 (resistor with M. crimpon terminal lugs) Note: Select this option from the OT parameter. Load resistance: 00 Ω or less Default: Unspecified retransmission type Allowable range: 00 V AC ( %) (free voltage) 0/0 Hz shared Relay contact rating: 0 V AC, 1 A V DC, 1 A (resistance load) DI DI Manual switching when DI changes to on Twowire transmitter Note: External Contact Input If the power is turned on when the external contact input (either of Cascade, Automatic, and Manual) is ON,the controller judges that the external contact input is changed to ON. Loop power Contact rating: V DC, ma or more supply..0 V DC madc * OT is a setup parameter. You can change the settings of the parameter OT to change the control output type. Correspondence between parameter OT and control output types OT= OT= OT=1 OT=0 (factoryset default) Note: Connecting a 0 resistor to the is optional. Model: X00 (resistor with M. crimpon terminal lugs) Onoff control Relay output (, and ) 1 1 Current output ( and ) Time proportional control Voltage pulse output ( and ) Time proportional control Relay output (, and ) All Rights Reserved. Copyright 00, Yokogawa Electric Corporation GS 0D01C0E nd Edition Jul., 000

15 UT Loop Control for Backup, Terminal Arrangements RS communication * Wiring can only be carried out input TC input RTD input 11 A b B for controllers with communication functions. Maximum baud rate: 00 bps SDB() SDA() RDB() RDA() SG Note: Select this option from the OT1 parameter. Relay contact output *Time proportional PID relay contact output is configured at factory before shipment. 1 NC NO Contact rating: 0 V AC, A V DC, A (resistance load) Before carrying out wiring, turn off the power to the controller and check that cables to be connected are not alive with a tester or the like because there is a possibility of electric shock. Power supply CAUTION Power supply L 1 N * The functionality of a contact input can be varied by changing the setting of the contact input registration parameter. * The functionality of a contact output can be varied by changing the setting of the contact output registration parameter. V 1 DI1 V External contact inputs UT DI1 1 External contact outputs Alarm 1 output DO1 Tracking Signal (host device operation output) Auxiliary input 1 Specify in a range of V DC, 0 V DC, or 0 V DC. Contact Transistor contact DI Default: V DC V DC Power Supply Wired to Sensor in Twowire System Configuration DI AUTO when DI1=ON MAN when DI1=OFF STOP when DI=ON RUN when DI=OFF UT DO DO Alarm output FAIL output Relay input 0..0 V DC signal 0 External resistor (Note) DI No function DI V V (ON when normal) mv/v input * Factoryset to retransmission. Retransmission output 1* * Retransmission output is available only when relay is selected as the type of control output. or 0 ma DC Default: ma DC * Retransmission output 1 is not available if a V DC loop power supply is used. V DC loop power supply*..0 V DC (1 ma DC max.) Retransmission output * Current/voltage pulse output 0mADC, madc 0mADC, madc Voltage pulse ( V) Default: ma DC Receiving ma DC Current Signals with the Controller * Not configured at factory before shipment * When receiving ma DC current signals, set the input type to V DC (setpoint 1 ). 0 Ω ma Note: Connecting a 0 Ω resistor to the is optional. Model: X00 (resistor with M. crimpon terminal lugs) Note: Select this option from the OT1 parameter. Load resistance: 00 Ω or less Default: Unspecified retransmission type Allowable range: 00 V AC ( %) (free voltage) 0/0 Hz shared DI DI Output of tracking signal when DI=ON Output of PID computation when DI=OFF Relay contact rating: 0 V AC, 1 A V DC, 1 A (resistance load) Twowire transmitter Note: External Contact Input If the power is turned on when the external contact input is OFF, the mode (SPN, R/L, or ) existing before the power is turned off will be continued. (except for RUN/STOP) Contact rating: V DC, ma or more Loop power supply..0 V DC madc * OT1 is a setup parameter. You can change the settings of the parameter OT1 to change the control output type. Correspondence between parameter OT1 and control output types OT1= OT1= OT1=1 OT1=0 (factoryset default) Note: Connecting a 0 resistor to the is optional. Model: X00 (resistor with M. crimpon terminal lugs) Onoff control Relay output (, and ) 1 1 Current output ( and ) Time proportional control Voltage pulse output ( and ) Time proportional control Relay output (, and ) All Rights Reserved. Copyright 00, Yokogawa Electric Corporation GS 0D01C0E nd Edition Jul., 000

16 UT Loop Control with Switching, Terminal Arrangements RS communication * Wiring can only be carried out input 1 TC input RTD input 11 A b B for controllers with communication functions. Maximum baud rate: 00 bps SDB() SDA() RDB() RDA() SG Note: Select this option from the OT1 parameter. Relay contact output *Time proportional PID relay contact output is configured at factory before shipment. 1 NC NO Contact rating: 0 V AC, A V DC, A (resistance load) Before carrying out wiring, turn off the power to the controller and check that cables to be connected are not alive with a tester or the like because there is a possibility of electric shock. Power supply CAUTION Power supply L 1 N * The functionality of a contact input can be varied by changing the setting of the contact input registration parameter. * The functionality of a contact output can be varied by changing the setting of the contact output registration parameter. V 1 DI1 V External contact inputs UT DI1 1 External contact outputs Alarm 1 output DO1 input Auxiliary input 1 Specify in a range of V DC, 0 V DC, or 0 V DC. Contact Transistor contact DI DI Default: V DC V DC Power Supply Wired to Sensor in Twowire System Configuration AUTO when DI1=ON MAN when DI1=OFF STOP when DI=ON RUN when DI=OFF UT DO Alarm output NOTE 1: When operating paramter U set to "", effective to contact input. Relay input 0..0 V DC signal 0 External resistor (Note) DI No function DI V V DO Alarm output mv/v input * Factoryset to retransmission. Retransmission output 1* * Retransmission output is available only when relay is selected as the type of control output. or 0 ma DC Default: ma DC * Retransmission output 1 is not available if a V DC loop power supply is used. V DC loop power supply*..0 V DC (1 ma DC max.) Retransmission output * Current/voltage pulse output 0mADC, madc 0mADC, madc Voltage pulse ( V) Default: ma DC Receiving ma DC Current Signals with the Controller * Not configured at factory before shipment * When receiving ma DC current signals, set the input type to V DC (setpoint 1 ). 0 Ω ma Note: Connecting a 0 Ω resistor to the is optional. Model: X00 (resistor with M. crimpon terminal lugs) Note: Select this option from the OT1 parameter. Load resistance: 00 Ω or less Default: Unspecified retransmission type Allowable range: 00 V AC ( %) (free voltage) 0/0 Hz shared DI DI input when DI=ON input 1 when DI=OFF (NOTE 1) Relay contact rating: 0 V AC, 1 A V DC, 1 A (resistance load) Twowire transmitter Note: External Contact Input If the power is turned on when the external contact input is OFF, the mode (SPN, R/L, or ) existing before the power is turned off will be continued. (except for RUN/STOP) Loop power Contact rating: V DC, ma or more supply..0 V DC madc * OT1 is a setup parameter. You can change the settings of the parameter OT1 to change the control output type. Correspondence between parameter OT1 and control output types OT1= OT1= OT1=1 OT1=0 (factoryset default) Note: Connecting a 0 resistor to the is optional. Model: X00 (resistor with M. crimpon terminal lugs) Onoff control Relay output (, and ) 1 1 Current output ( and ) Time proportional control Voltage pulse output ( and ) Time proportional control Relay output (, and ) All Rights Reserved. Copyright 00, Yokogawa Electric Corporation GS 0D01C0E nd Edition Jul., 000

17 <<Contents>> <<Index>> External Dimensions and Panel Cutout Dimensions Unit: mm 11 0 Small bracket LP MAN Small bracket 1 to mm (Panel thickness) General installation 0 min. Sidebyside close installation [(N1) ] () 0. 0 min. N stands for the number of controllers to be installed. However, the measured value applies if N () All Rights Reserved. Copyright 00, Yokogawa Electric Corporation GS 0D01C0E nd Edition Jul., 000

18 Model and Suffix Codes Model Suffix Code Description UT Digital indicating controller (provided with retransmission output and V DC loop power supply as standard) Type 0 Standard type 0 None Optional functions With communication, auxiliary analog (remote) input, and additional DIs With auxiliary analog (remote) input and additional DIs Standard accessories: Brackets (mounting hardware), unit label, User s Manuals, and User s Manual (reference) (CDROM version). Specify the required optional function codes according to the UT mode to be used. Correspondence between UT mode and suffix code UT mode Specification code Remarks Singleloop control (UT mode 1) Cond. App. App. Cond.: Remote target setting not available The remote target setting function requires the auxiliary analog input (optional function) to be specified. Cascade primary loop control (UT mode ) Cascade secondary loop control (UT mode ) Cascade control (UT mode ) Loop control for backup (UT mode ) Loop control with switching (UT mode ) Loop control with autoselector (UT mode ) Loop control with hold function (UT mode ) N/A N/A N/A N/A N/A N/A Cond. App. App. App. App. App. App. App. App.: Function available, Cond.: Function available conditionally, N/A: Function not available App. App. App. Auxiliary analog input is used for the cascade input. App. Auxiliary analog input is used for the tracking input. App. Auxiliary analog input is used for the input. App. Auxiliary analog input is used for the input. App. Cond.: Remote target setting not available The remote target setting function requires the auxiliary analog input (optional function) to be specified. Correspondence between the Model and Suffix Codes, and the Contact Input/Output Terminals Provided Check the model ordered and the presence/absence of contact inputs and outputs in the following table. indicate that the contacts are available. Model and Suffix Contact input Contact output Codes DI1 DI DI DI DI DI DI DI DO1 DO DO DO DO DO DO UT00 UT0 UT0 Items to be Specified When Ordering Model and suffix codes, necessary/unnecessary of User s Manual or QIC. All Rights Reserved. Copyright 00, Yokogawa Electric Corporation GS 0D01C0E nd Edition Jul., 000

General Specifications

General Specifications General Specifications MODEL UT0 Digital Indicating Controller GS 0D01C00E General Model UT0 Digital Indicating Controller is an intelligent, microprocessor based digital indicating controller with powerful

More information

General Specifications

General Specifications General Specifications Model UM350 Digital Indicator with Alarms GS 05F0D00E General Model UM350 Digital Indicator with Alarms is a precision alarm instrument with universal input. For excellent monitoring

More information

General Specifications

General Specifications General Specifications Model UM330 Digital Indicator with Alarms GS 05F0D00E General Model UM330 Digital Indicator with Alarms is a precision alarm instrument with universal input /8DIN. For excellent

More information

General Specifications

General Specifications General Specifications GS 0F01D0E Model UM1 Digital Indicator with Alarms with Active Color PV Display General Model UM1 Digital Indicator with Alarms is a precision 1/8 DIN alarm instrument provided with

More information

General Specifications

General Specifications General Specifications MODEL 550 Digital Indicating Controller GS 05D0C00E General Model 550 Digital Indicating Controller is an intelligent, microprocessor based digital indicating controller with powerful

More information

General Specifications

General Specifications General Specifications MODEL UM0 Digital Indicator with Alarms GS 0F0D00E General Model UM0 Digital Indicator with Alarms is a precision alarm instrument with universal input /8DIN. For excellent monitoring

More information

General Specifications

General Specifications General Specifications GS 05F01D01E MODEL UM351 Digital Indicator with Alarms with Active Color PV Display General Model UM351 Digital Indicator with Alarms is a precision alarm instrument provided with

More information

General Specifications

General Specifications General Specifications GS 0F01D01E Model UM1 Digital Indicator with Alarms with Active Color PV Display General Model UM1 Digital Indicator with Alarms is a precision alarm instrument provided with universal

More information

General Specifications

General Specifications General Specifications Model 0 Digital Indicating Controller GS 0D0C00E General Model 0 Digital Indicating Controller is an intelligent, microprocessor based digital indicating controller with powerful

More information

General Specifications

General Specifications General Specifications Model UT30 Digital Indicating Controller GS 05D0D00E General Model UT30 Digital Indicating Controller is a highly accurate /8 DIN controller, provided with universal input/ output.

More information

General Specifications

General Specifications General Specifications Model UP350 Program Controller GS 05E0D00E General Model UP350 program controller is a precision controller, featuring two program profiles and universal input/output. For easy operation,

More information

General Specifications

General Specifications General Specifications GS 05D01D01E Model UT351 Digital Indicating Controller with Active Color PV Display General Model UT351 Digital Indicating Controller is a highly accurate 1/4 DIN controller, provided

More information

General Specifications

General Specifications General Specifications MODEL UT50L Limit Controller GS 5DD-0E Overview The UT50L is an FM approved limit controller that can be configured either as a high limit or as a low limit controller by a user.

More information

General Specifications

General Specifications General Specifications Model UT, UT Temperature Controller GS CE-E GENERAL UT series temperature controllers provide only the functions and size you require for your application. /6 DIN sizes is available.

More information

Models UT550/UT520 Digital Indicating Controllers User s Manual for Loop Control for Backup

Models UT550/UT520 Digital Indicating Controllers User s Manual for Loop Control for Backup Instruction Manual Models UT550/UT520 Digital Indicating Controllers User s Manual for Loop Control for Backup IM 05D01C02-45E IM 05D01C02-45E 1st Edition Blank Page Introduction Thank you

More information

Models UT550/UT520 Digital Indicating Controllers User s Manual for Single-loop Control

Models UT550/UT520 Digital Indicating Controllers User s Manual for Single-loop Control User s Manual Models UT550/UT520 Digital Indicating Controllers User s Manual for Single-loop Control IM 05D01C02-41E IM 05D01C02-41E 3rd Edition Blank Page Introduction i Thank you for purchasing

More information

General Specifications

General Specifications General Specifications GS 05D0B00E Model UT750 Digital Indicating Controller (with Custom Computation) General Model UT750 Digital Indicating Controller is an intelligent, microprocessor based digital

More information

Models UT350/UT320 Digital Indicating Controllers

Models UT350/UT320 Digital Indicating Controllers User s Manual Models UT350/UT320 Digital Indicating Controllers User s Manual IM 05D01D02-41E IM 05D01D02-41E 4th Edition Blank Page Introduction i Thank you for purchasing the UT350/UT320

More information

Model UT551 Digital Indicating Controller with Active Color PV Display and Embedded Ethernet User s Manual for Single-loop Control

Model UT551 Digital Indicating Controller with Active Color PV Display and Embedded Ethernet User s Manual for Single-loop Control User s Manual Model UT551 Digital Indicating Controller with Active Color Display and Embedded Ethernet User s Manual for Single-loop Control IM 05D01C03-41E IM 05D01C03-41E 4th Edition Introduction

More information

Model UP350 Program Controller

Model UP350 Program Controller User s Manual Model UP350 Program Controller User s Manual IM 05E01D02-41E IM 05E01D02-41E 2nd Edition Blank Page Introduction i Thank you for purchasing the UP350 program controller. How to

More information

General Specifications

General Specifications General Specifications GS 05P01F31-01EN UT32A Digital Indicating Controller (Entry model) Functional Enhancement Overview The UT32A entry model digital indicating controller is an easily configurable single-loop

More information

Model UT750 Digital Indicating Controller User s Manual for Cascade Control

Model UT750 Digital Indicating Controller User s Manual for Cascade Control User s Manual Model UT750 Digital Indicating Controller User s Manual for Cascade Control IM 05D01B02-44E IM 05D01B02-44E 3rd Edition Blank Page Introduction i Thank you for purchasing the

More information

General Specifications

General Specifications General Specifications UM33A Digital Indicator with Alarms [Style: S9] Overview The UM33A digital indicator with Alarms employ an easy-to-read, 14-segment large color LCD display, along with navigation

More information

Model UP550 Program Controller User s Manual for Loop Control with PV Switching

Model UP550 Program Controller User s Manual for Loop Control with PV Switching User s Manual Model UP550 Program Controller User s Manual for Loop Control with Switching IM 05E0C0-46E IM 05E0C0-46E 3rd Edition Blank Page Introduction i Thank you for purchasing the UP550

More information

Model UP351 Program Controller

Model UP351 Program Controller User s Manual Model UP351 Program Controller User s Manual IM 05E01D12-41E IM 05E01D12-41E 4th Edition Blank Page Introduction i Thank you for purchasing the UP351 program controller. How to

More information

Model UP750 Program Controller User s Manual for Dual-loop Control

Model UP750 Program Controller User s Manual for Dual-loop Control Instruction Manual Model UP750 Program Controller User s Manual for Dual-loop Control IM 05E0B0-5E IM 05E0B0-5E st Edition Blank Page Introduction i Thank you for purchasing the UP750 program

More information

Model UT750 Digital Indicating Controller User s Manual for Cascade Primary-loop Control

Model UT750 Digital Indicating Controller User s Manual for Cascade Primary-loop Control User s Manual Model UT750 Digital Indicating Controller User s Manual for Cascade Primary-loop Control IM 05D01B02-42E IM 05D01B02-42E 3rd Edition Blank Page Introduction i Thank you for purchasing

More information

General Specifications

General Specifications General Specifications GS 05P08D81-01EN UT32A-D/MDL Digital Indicating Controller (Dual-loop, DIN Rail Mounting Type) Functional Enhancement Overview The UT32A-D/MDL controller is a dual-loop controller

More information

Model UP550 Program Controller User s Manual for Cascade Primary-loop Control

Model UP550 Program Controller User s Manual for Cascade Primary-loop Control Instruction Manual Model UP550 Program Controller User s Manual for Cascade Primary-loop Control IM 05E0C02-42E IM 05E0C02-42E st Edition Blank Page Introduction i Thank you for purchasing

More information

General Specifications

General Specifications General Specifications GS 05P08D3101EN UT32AD Digital Indicating Controller (Dualloop, Panel Mounting Type) Functional Enhancement Overview The UT32AD dualloop digital indicating controllers employ an

More information

How to Install CAUTION. Panel. 150mm. 150mm. Direction to insert the controller Insert the controller into the opening at the front of the panel.

How to Install CAUTION. Panel. 150mm. 150mm. Direction to insert the controller Insert the controller into the opening at the front of the panel. User s IM DDE This manual describes installation, wiring, and other tasks required to make the ler ready for operation.. Safety Precautions. Model and Suffix Codes. How to Install. How to Connect Wires.

More information

General Specifications

General Specifications General Specifications GS 05P03D21-01EN UM33A Digital Indicator with Alarms Functional Enhancement Overview The UM33A digital indicator with Alarms employ an easy-to-read, 14-segment large color LCD display,

More information

General Specifications

General Specifications General Specifications GS 77J0A070E Model VJA7 Distributor (Multifunction) (Isolated Singleoutput and Isolated Dualoutput Types) Overview This plugin type distributor is used in combination with wire type

More information

General Specifications

General Specifications General Specifications GS 77J01Q08-01E Model VJQ8 Pulse to Analog Converter (Multi-function) (Isolated Single-output and Isolated Dual-output Types) General This plug-in type pulse to analog converter

More information

indicate that the contacts are available. How to Install CAUTION Panel

indicate that the contacts are available. How to Install CAUTION Panel s Manual IM DCE This manual describes installation, wiring, and other tasks required to make the controller ready f operation.. Safety Precautions. Model and Suffix Codes. How to Install How to Connect

More information

DIGITAL PROGRAM CONTROLLER

DIGITAL PROGRAM CONTROLLER KP1000 SERIES DIGITAL PROGRAM CONTROLLER The KP1000 series is a 96x96mm digital program controller with the indicating accuracy of ±0.1%, the control cycle of approximately 0.1 seconds and maximum 19 program

More information

MICRO-CONTROLLER X (48 48 mm)

MICRO-CONTROLLER X (48 48 mm) PX series digital temperature controller MICRO-CONTROLLER X ( mm) DATA SHEET PXG PXG is a compact size temperature controller of front panel size mm. To cope with any of versatile uses as a temperature

More information

General Specifications

General Specifications General Specifications Model UT350 Digital Indicating Controller GS 05D0D00E General Model UT350 Digital Indicating Controller is a highly accurate /DIN controller provided with universal input/ output.

More information

SHIMADEN DIGITAL INDICATORS

SHIMADEN DIGITAL INDICATORS Shimaden, Temperature and Humidity Control Specialists C %RH Series SD16A & SHIMADEN DIGITAL INDICATORS approved,ul applied BASIC FEATURES compliance DIN Size 48 x 96 mm ±.3% High Accuracy Indication Large

More information

SHIMADEN PROGRAM CONTROLLER

SHIMADEN PROGRAM CONTROLLER Shimaden, Temperature and Humidity Control Specialists C %RH SHIMADEN PROGRAM CONTROLLER approved BASIC FEATURES Full multi-input and multi-range performance User selectable Thermocouple, RTD, V, mv and

More information

Temperature Controllers E5 J

Temperature Controllers E5 J Temperature Controllers Advanced PID Controller with Fuzzy Logic-Based Adaptive Tuning Provides Optimum Performance Available in 3 standard DIN sizes: Choose 1/4, 1/8 and 1/16 DIN Fuzzy adaptive tuning

More information

SDC40A. DigitroniK TM Digital Indicating Controller RSW. Control unit PID (8) Auto tuning+ Neuro & Fuzzy RUN/READY R/L LSP.

SDC40A. DigitroniK TM Digital Indicating Controller RSW. Control unit PID (8) Auto tuning+ Neuro & Fuzzy RUN/READY R/L LSP. No. CP-SS-580E SDC40A DigitroniK TM Digital Indicating Controller Overview The DigitroniK TM SDC40A is a compact (96mm x 96mm) digital controller. The SDC40A features a wide variety of input options: thermocouples,

More information

PROCESS & TEMPERATURE CONTROLLERS

PROCESS & TEMPERATURE CONTROLLERS PROCESS & TEMPERATURE CONTROLLERS NOVA PD54 Series Thermocouple, RTD, & Process Inputs High Accuracy Auto-Tuning PID Heating & Cooling Models Universal Power Supply 1-24 VAC Up to 3 Relays & 2 Analog Outputs

More information

General Specifications

General Specifications General Specifications 35A/32A Digital Indicating Controllers [Style: S1] Overview The 35A/32A digital indicating controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation

More information

MICRO-CONTROLLER X (96 96 mm)

MICRO-CONTROLLER X (96 96 mm) PX series digital temperature controller MICRO-CONTROLLER X ( mm) DATA SHEET PXG PXG is a compact size temperature controller of front panel size mm. To cope with any of versatile uses as a temperature

More information

DIGITAL INDICATING CONTROLLER

DIGITAL INDICATING CONTROLLER DB00 SERIES DIGITAL INDICATING CONTROLLER The DB00 series is a digital indicating controller with the indicating accuracy of ±0.% and the control cycle of approximately 0. seconds. Various functions including

More information

User s Manual. Model US1000 Digital Indicating Controller Functions. IM 5D1A01-02E 2nd Edition IM 5D1A01-02E

User s Manual. Model US1000 Digital Indicating Controller Functions. IM 5D1A01-02E 2nd Edition IM 5D1A01-02E User s Manual Model US1000 Digital Indicating Controller Functions 2nd Edition Introduction This instruction manual describes the functions of the US1000 Digital Indicating Controller in detail. Read

More information

Digital Controller Intelligent, User-friendly Digital Controller and Programmer Controlled with ease with a support software which is input via the communication jack on the front panel. Minute adjustment

More information

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION ADVANCED - CONTROLLERS - SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION (ma) OUTPUTS - 4x EVENT OR ALARM OUTPUTS

More information

Single Loop Controller SDC35/36

Single Loop Controller SDC35/36 No. CP SS 180E Single Loop Controller SDC35/36 Features The DigitroniK SDC35/36 is a digital indicating controller featuring multi-range inputs and PID control system using new algorithms "RationaLOOP"

More information

UT750. Relay. 150mm. UT s contact. Relay (Use one with a relay coil rating less than the UT s contact rating.) 150mm. Recommended Terminal Lugs

UT750. Relay. 150mm. UT s contact. Relay (Use one with a relay coil rating less than the UT s contact rating.) 150mm. Recommended Terminal Lugs User s Manual IM 5DBE This manual describes installation, wiring, and other tasks required to make the controller ready f operation.. Safety Precautions. Model and Suffix Codes. How to Install. How to

More information

High Performance Process & Temperature Controllers

High Performance Process & Temperature Controllers C22 C62 C82 C83 High Performance Process & Temperature Controllers C72 C42 R22 01. Multi Color LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. 200 msec Sampling Rate 04. True Universal

More information

General Specifications

General Specifications General Specifications MODEL UP750 ler GS 5EB0-0E General Model UP750 ler is an intelligent, microprocessor based program controller that has the capacity of 00 program s, ful control capability, custom

More information

MICRO-CONTROLLER X (48 96 mm)

MICRO-CONTROLLER X (48 96 mm) PX series digital temperature controller MICRO-CONTROLLER X ( mm) DATA SHEET PXG PXG is a compact size temperature controller of front panel size mm. To cope with any of versatile uses as a temperature

More information

Jacket heater, etc Mounting bracket for Pipe wrapping. (Optional) Temperature sensor. Output (To heater) (Optional)

Jacket heater, etc Mounting bracket for Pipe wrapping. (Optional) Temperature sensor. Output (To heater) (Optional) Temperature Controller with Built-in SSR SB SB General Description SB is a channel temperature controller with Built-in SSR (Solid state relay) designed for flexible heating solutions such as heat trace

More information

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

MODEL: M2XU MODEL: M2XU [1][2] [3][4] Super-mini Signal Conditioners Mini-M Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Accepts direct inputs from various sensors and provides a standard process signal I/O types and

More information

SHIMADEN DIGITAL INDICATOR

SHIMADEN DIGITAL INDICATOR Shimaden, Temperature and Humidity Control Specialists C %RH Series SD24 & KR16A SHIMADEN DIGITAL INDICATOR BASIC FEATURES ohigh Accuracy ±0.1% FS+1 digit o1/1000ºc Resolution Indication Possible (Pt input

More information

General Specifications

General Specifications General Specifications GS 77J04H0-0E Model MH Isolator (Free Range Type) General The MH is a plug-in type isolator that converts DC current or DC voltage signals into isolated DC current or DC voltage

More information

DigitroniK TM Digital Indicating Controller SDC20

DigitroniK TM Digital Indicating Controller SDC20 No. CP SS 47E DigitroniK TM Digital Indicating Controller SDC The DigitroniK SDC is a compact digital controller with multi-range and PID autotuning systems for various inputs, with time proportional (on/off)

More information

DIGITAL THERMOMETER Digital Thermometer FEATURES INDEX RECORDERS

DIGITAL THERMOMETER Digital Thermometer FEATURES INDEX RECORDERS Digital Thermometer 23 88 350 mm 3 kg (8-5/8 3-/2 3-3/4" 6.6 lbs) The Digital Thermometer has 6 ranges of temperature sensors and measuring functions of DC V and Ω. YOKOGAWA-original A/D converter (feedback

More information

General Specifications

General Specifications General Specifications Signal Conditioner Cards OUTLINE Signal Conditioner Cards, which interface to the process, are installed in Signal Conditioner Nests. [Release 6] The signal conditioner cards can

More information

PROGRAM CONTROLLER OUTLINE

PROGRAM CONTROLLER OUTLINE Specifications Sheet No.SPEC-1232E (1st Edition) EC1200A PROGRAM CONTROLLER OUTLINE The EC1200 can, totally and with high precision, control and monitor such factors as temperature, temperature balance

More information

DIGITAL THERMOMETER VIEW RECORDERS Digital Thermometer FEATURES

DIGITAL THERMOMETER VIEW RECORDERS Digital Thermometer FEATURES Digital Thermometer High-Accuracy Reference Junction Compensation: Compensation accuracy (±0.2 C) Input terminals are provided on both front and rear panels, and an input site is switch selectable. The

More information

General Specifications

General Specifications General Specifications GS J0U0-0E Model MU Universal Temperature Converter (Free Range Type) General The MU is a plug-in type universal temperature converter that converts input signal (thermocouple, RTD

More information

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4] Tension-Clamp Ultra-Slim Signal Conditioners M6S Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection Universal input (mv, V, ma, T/C, RTD and potentiometer)

More information

Excellent low-cost Process & Temperature Controllers

Excellent low-cost Process & Temperature Controllers C22 C62 C82 C83 Excellent low-cost Process & Temperature Controllers C72 C42 R22 01. High Quality LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. The Fast Sampling Rate in 200

More information

6/12/24 Dot Printing Model Smart Recorder SRF206/212/224

6/12/24 Dot Printing Model Smart Recorder SRF206/212/224 No. CP-SS-E // Dot Printing Model Smart Recorder SRF0// The Smart Recorder SRF 0// Dot Printing Model accepts DC voltage, thermocouple, resistance temperature detector (RTD), communications and ON/OFF

More information

DC1010/DC1020/DC1030/DC1040

DC1010/DC1020/DC1030/DC1040 05/0 0-10-10-0-EN Page 1 of DC1010/DC1020/DC100/DC1040 DIGITAL CONTROLLERS Specification Overview The DC1000 Series are microprocessorbased controllers designed with a high degree of functionality and

More information

K3P ENG.qxd 23/10/ Pagina 1

K3P ENG.qxd 23/10/ Pagina 1 K3P ENG.qxd 23/10/2003 12.30 Pagina 1 - CLEAR PROGRAM STATUS DISPLAY - DIRECT PROGRAM PARAMETER ADJUSTMENT - 8 INDEPENDENT PROGRAMS - 10 SEGMENTS FOR EACH PROGRAM - "SET - POINT TRACKING " AND "GUARANTEED

More information

Basic module X-TIO FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10 FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10. Communications (RS-485)

Basic module X-TIO FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10 FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10. Communications (RS-485) Module type High-speed Digital ler SRX SRX General Description The SRX is a module type digital controller with a super high speed sampling of control updating cycle time of ms (0.0 sec). Dual loop control

More information

HA400 HA900 HA401 HA901

HA400 HA900 HA401 HA901 A/ R/L R/S High-Speed Digital Controller - or loops HA Series HA00 HA900 HA0 HA90 General Description he HA series are digital PID controllers with a high speed sampling time of ms (0.0 sec) with high-resolution

More information

APPENDIX APPENDIX A 1

APPENDIX APPENDIX A 1 A 1 SPECIFICATIONS Ratings Supply voltage 100 to 240 VAC, 50/60 Hz 24 VAC, 50/60 Hz/24 VDC Operating voltage range 85 to 110% of rated supply voltage Power consumption 7VA 4VA/2.5W Sensor input Thermocouple

More information

Process and Temperature Controllers

Process and Temperature Controllers Process and Temperature Controllers www.durexindustries.com Input Input Input break action Input short action Sampling time Influence of external resistance Influence of lead resistance PV bias Input

More information

General Specifications

General Specifications General Specifications Signal Conditioner Cards GS 33K50H80-50E OUTLINE Signal Conditioner Cards, which interface to the process, are installed in Signal Conditioner Nests. [Release 5] The signal conditioner

More information

MODEL: R30US4. Remote I/O R30 Series

MODEL: R30US4. Remote I/O R30 Series Remote I/O R30 Series UNIVERSAL INPUT MODULE (4 points, isolated) Functions & Features 4 points universal input I/O module Isolation between the channels Input range of each channel is individually adjustable

More information

SHIMADEN DIGITAL INDICATORS

SHIMADEN DIGITAL INDICATORS Shimaden, Temperature and Humidity Control Specialists C %RH Series SD16 & SHIMADEN DIGITAL INDICATORS & NRTL /C approved BASIC FEATURES DIN Size 48 x 96 mm ±.3% High Accuracy Indication Large 2 mm bright

More information

PROGRAMMABLE CONTROLLER

PROGRAMMABLE CONTROLLER Shimaden, Temperature and Humidity Control Specialists C %RH Series FP2 PROGRAMMABLE CONTROLLER approved UL applied BASIC FEATURES 2-channel controller (Basic type: 1-channel controller) Independent 2-loop

More information

Fuzzy Temperature Controllers E5AF

Fuzzy Temperature Controllers E5AF Fuzzy Temperature Controllers 1/4 DIN Controller Combines Fuzzy and PID Control For Fast Response to Process Disturbances Advanced PID control provides optimal response during start-up and steadystate

More information

General Specifications

General Specifications General Specifications GS 05P01D3181EN 35A/RSP, 32A/RSP Digital Indicating Controller (with Nonisolated Remote Input) Functional Enhancement Overview The 35A/RSP and 32A/RSP are singleloop controller with

More information

SR25. SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists MICROPROCESSOR-BASED AUOT-TUNING PID CONTROLLER

SR25. SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists MICROPROCESSOR-BASED AUOT-TUNING PID CONTROLLER SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists SERIES SR25 MICROPROCESSOR-BASED AUOT-TUNING PID CONTROLLER High Accuracy ±0.1% High Sampling Cycle 0.1 sec. Auto-Tuning

More information

General Specifications

General Specifications General Specifications GS J0X-0E Model MXT Universal Computing Unit (-input, Isolated -output Type) General This plug-in type universal computing unit receives DC current or DC voltage signals, applies

More information

UP550 O.C. Relay. UP s contact. 150mm. Relay. (Use one with a relay coil rating less than the UP s contact rating.) 150mm. Recommended Terminal Lugs

UP550 O.C. Relay. UP s contact. 150mm. Relay. (Use one with a relay coil rating less than the UP s contact rating.) 150mm. Recommended Terminal Lugs s Manual IM ECE This manual describes installation, wiring, and other tasks required to make the controller ready f operation.. Safety Precautions. Model and Suffix Codes. How to Install. How to Connect

More information

General Specifications

General Specifications General Specifications GS 05P01C3101EN 55A, 52A Digital Indicating Controller (Panel Mounting Type) Functional Enhancement Overview The 55A and 52A digital indicating controllers employ an easytoread,

More information

DCP551B Mark II. DIGITRONIK TM Programmable Controller. Control operation block. Mode transition. PID control Auto-tuning.

DCP551B Mark II. DIGITRONIK TM Programmable Controller. Control operation block. Mode transition. PID control Auto-tuning. No. CP-SS-1852E DCP551B Mark II DIGITRONIK TM Programmable Controller Overview The DIGITRONIK TM DCP551B Mark II is a high-function programmable controller supporting up to 99 program patterns to which

More information

ADAM 4000/4100 Series

ADAM 4000/4100 Series ADAM 4000/4100 Series Common Dimensions Communication RS-485 (2-wire) to host Speeds: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps (ADAM-4080, ADAM-4080D only support up to 38400 bps) Max. communication

More information

Fuzzy Temperature Controllers E5EF

Fuzzy Temperature Controllers E5EF Fuzzy Temperature lers EEF / DIN lers Combine Fuzzy and PID For Fast Response to Process Disturbances dvanced PID control for optimal response during startup and steadystate operation Fuzzy and PID control

More information

Ramp/Soak Temperature Controller REX-P250

Ramp/Soak Temperature Controller REX-P250 EX-P0 General The EX-P0 is a high performance ramp/soak controller with a storage capacity of segments in patterns. Each pattern consists of up to segments and patterns can be linked for maximum pattern

More information

General Specifications

General Specifications General I/O Adaptors (for N-IO) GS 33J62F30-01EN [Release 6] GENERAL This General (GS) describes the hardware specifications of I/O adaptors that enable extended functions setting for analog digital I/O

More information

SDC45V/46V. DigitroniK TM Digital Indicating Controller. Control Operation

SDC45V/46V. DigitroniK TM Digital Indicating Controller. Control Operation No. CP-SS-848E SDC45V/46V DigitroniK TM Digital Indicating Controller Overview The SDC45V/46V DigitroniK is a highly advanced, highprecision compact digital indicating controller, featuring a 5-digit indicator,

More information

General Specifications

General Specifications General Specifications 35A/32A Digital Indicating Controllers [Style: S5] Overview The 35A/32A digital indicating controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation

More information

General Specifications

General Specifications General Specifications GS 05P01D3101EN 35A, 32A Digital Indicating Controller (Panel Mounting Type) Functional Enhancement Overview The 35A and 32A digital indicating controllers employ an easytoread,

More information

DCP552B Mark II. DIGITRONIK TM Programmable Controller. Control operation block. Mode transition. PID control Auto-tuning.

DCP552B Mark II. DIGITRONIK TM Programmable Controller. Control operation block. Mode transition. PID control Auto-tuning. No. CP-SS-1853E DCP552B Mark II DIGITRONIK TM Programmable Controller Overview The DIGITRONIK TM DCP552B Mark II is a high-function programmable controller supporting two channels (up to 49 program patterns

More information

- SMART TUNE - PID CONTROL - UNIVERSAL, 3 WIRE - TC, RTD AND LINEAR INPUT - 2 INDEPENDENT SET POINT RAMP UP/ DOWN PROFILES - SERVO VALVE POSITIONER

- SMART TUNE - PID CONTROL - UNIVERSAL, 3 WIRE - TC, RTD AND LINEAR INPUT - 2 INDEPENDENT SET POINT RAMP UP/ DOWN PROFILES - SERVO VALVE POSITIONER MULTI - FUNTION ONTROLLERS - SMART TUNE - PID ONTROL - UNIVERSAL, 3 WIRE - T, RTD AND LINEAR INPUT - 2 INDEPENDENT SET POINT RAMP UP/ DOWN PROFILES - SERVO VALVE POSITIONER WITH POTENTIOMETER FEEDBAK -

More information

DigitroniK TM Digital Indicating Controller SDC40A

DigitroniK TM Digital Indicating Controller SDC40A No. CPSS580E DigitroniK TM Digital Indicating Controller SDC40A The DigitroniK TM SDC40A is a compact (96mm x 96mm) digital controller. The SDC40A features a wide variety of input options: thermocouples,

More information

MODEL: M2EXT. Super-mini Signal Conditioners with Display Mini-M M2E Series

MODEL: M2EXT. Super-mini Signal Conditioners with Display Mini-M M2E Series Super-mini Signal Conditioners with Display Mini-M ME Series THERMOCOUPLE TRANSMITTER (PC programmable) Functions & Features Accepts direct input from a thermocouple and provides a linearized process signal

More information

µr SERIES RECORDERS VIEW RECORDERS 4365 & 4375 Recorders FUNCTIONS FEATURES

µr SERIES RECORDERS VIEW RECORDERS 4365 & 4375 Recorders FUNCTIONS FEATURES 4365 & 4375 Recorders VIEW RECORDERS Splash and dust-proof door permits use even in poor environments. (Based on DIN 40050-IP54). Depth is a mere 220 mm, enabling significant instrument panel space savings.

More information

DigitroniK Digital Indicating Controller SDC30

DigitroniK Digital Indicating Controller SDC30 No. CPSS86E DigitroniK Digital Indicating Controller SDC0 The DigitroniK SDC0 is a compact (48 mm x 96 mm) digital indicating controller offering standard PID control and an advanced neural/fuzzy PID that

More information

DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification

DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification 01 May 20 30-10-10--EN Page 1 of DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification Overview The DC1000 Series are microprocessorbased controllers designed with a high degree of

More information

CompoBus/D-type Digital Controller

CompoBus/D-type Digital Controller CompoBus/D-type Digital Controller Digital Controller for the CompoBus/D and Conforming the DeviceNet Conforms the DeviceNet and connects a Programmable Controller without any programming. High performance

More information

Process displays For standard signals, temperature, resistance measurement

Process displays For standard signals, temperature, resistance measurement Features Inputs: Voltage ±10 V, ±200 V / Current ±20 ma / thermocouples J,K,T,N,Pt100,Pt1000 / resistance measurement / potentiometer Display range can be linearised Two limits output Min, Max functions

More information