MODEL: KS. Plug-in Signal Conditioners K-UNIT
|
|
- Owen Ryan
- 5 years ago
- Views:
Transcription
1 Plug-in Signal Conditioners K-UNIT DC ALARM Functions & Features Providing relay contact closures at preset DC input levels Dual (Hi/Lo) trip Multi-turn screwdriver setpoint adjustments Monitor jacks provided for setpoint adjustments Enclosed relays Relays can be powered 0 V DC Isolation up to 000 V AC High-density mounting Typical Applications Annunciator Various alarm applications K UNIT Model KS SET MONITOR 000% (00VDC) SET HI HI COM 0 (.) * (.) 0 (.) * (.0) for KS- mm (inch) MODEL: KS[][][][] ORDERING INFORMATION Code number: KS-[][]-[][] Specify a code from below for each [] through []. (e.g. KS--B/Q) Special input range (For codes Z & 0) Specify the specification for option code /Q (e.g. /C0/S0) [] INPUT Current A: 0 ma DC ( resistance 0 Ω) A: 0 ma DC ( resistance 0 Ω) B: 0 ma DC ( resistance 00 Ω) C: ma DC ( resistance 000 Ω) D: 0 0 ma DC ( resistance 0 Ω) E: 0 ma DC ( resistance. Ω) F: 0 0 ma DC ( resistance 00 Ω) G: 0 ma DC ( resistance 000 Ω) H: 0 0 ma DC ( resistance 00 Ω) J: 0 0 μa DC ( resistance 000 Ω) K: 0 00 μa DC ( resistance 000 Ω) GW: - ma DC ( resistance 000 Ω) FW: -0 0 ma DC ( resistance 00 Ω) Z: Specify current (See INPUT SPECIFICATIONS) Voltage : 0 0 mv DC ( resistance 0 kω min.) : 0 0 mv DC ( resistance 0 kω min.) : 0 0 mv DC ( resistance 0 kω min.) : 0 00 mv DC ( resistance 00 kω min.) : 0 V DC ( resistance MΩ min.) : 0 0 V DC ( resistance MΩ min.) : 0 V DC ( resistance MΩ min.) : V DC ( resistance MΩ min.) W: -0 0 V DC ( resistance MΩ min.) W: - V DC ( resistance MΩ min.) 0: Specify voltage (See INPUT SPECIFICATIONS) [] OUTPUT : Open collector : Relay; N.O. or make contact : Relay; N.C. or break contact : SSR : Relay; SPDT or transfer contact [] POWER INPUT AC Power B: 00 V AC C: 0 V AC D: V AC F: 0 V AC G: 00 V AC H: 0 V AC J: 0 V AC DC Power S: V DC R: V DC [] OPTIONS blank: none /Q: With options (specify the specification) SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) /C0: Silicone coating /C0: Polyurethane coating /C0: Rubber coating TERMINAL SCREW MATERIAL /S0: Stainless steel GENERAL SPECIFICATIONS Construction: Plug-in Connection: M. screw terminals KS SPECIFICATIONS ES- Rev.0 Page /
2 Screw terminal: Chromated steel (standard) or stainless steel Housing material: Flame-resistant resin (black) Isolation: to output to power Setpoint adjustments: Multi-turn screwdriver adjustments (front); 0 00% independently Monitor jacks: Output 0 0 V for 0 00 % setpoints Hysteresis (deadband): 0..0 % Front LEDs: Red lights turn on in tripped conditions Power ON timer: The output devices will not be driven for approx. sec. after the power is turned on. INPUT SPECIFICATIONS DC Current: Shunt resistor attached to the input terminals (0. W) Specify input resistance value for code Z. DC Voltage: V DC Minimum span: 0 mv Offset: Max.. times span resistance Span 0 00 mv : 0 kω Span 0. V : 00 kω Span V : MΩ OUTPUT SPECIFICATIONS Open Collector: 0 V ma Voltage drop: V Relay Contact: 0 V A (cos ø = ) 0 V A (cos ø = ) 0 V A (resistive load) Maximum switching voltage: 0 V AC or V DC Maximum switching power: 0 VA or 0 W Minimum load: V ma Mechanical life: 0 cycles For maximum relay life with inductive loads, external protection is recommended. SSR: 0 0 V A Leakage current at OFF: Approx. 0 ma (0 V AC) Alarm Trip Operation Terminal No. in parentheses Output Code :,, Output Code : Output Code : ()ON ()ON ()ON ()ON (0)ON ()ON ()ON ()ON Trip Operation in Power Failure Output Code :,, : both relays turn OFF Output Code : : both relays turn ON Output Code : : Terminals, turn ON INSTALLATION Power input AC: Operational voltage range: rating ±0 %, 0/0 ± Hz, approx. VA DC: Operational voltage range: rating ±0 %, ripple 0 %p-p max., approx. W (0 ma at V) Operating temperature: - to C ( to F) Operating humidity: 0 to 0 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 00 g (0. lb) PERFORMANCE in percentage of span Setpoint monitor accuracy: ± 0. % Temp. coefficient: ±0.0 %/ C (±0.0 %/ F) Response time: 0. sec. (0 00 % at 0 % setpoint) Line voltage effect: ±0. % over voltage range Insulation resistance: 00 MΩ with 00 V DC Dielectric strength: 000 V minute (input to output to power to ground) KS SPECIFICATIONS ES- Rev.0 Page /
3 EXTERNAL VIEW Hi Adj. Lo Adj. Hi Setpoint Monitor Lo Setpoint Monitor COM. Hi LED Lo LED DIMENSIONS unit: mm (inch) OUTPUT CODE:,,, CLAMP (top & bottom). (.) 0 (.) DIN RAIL mm wide 0 (.). (.) dia. MTG HOLE (.) deep 0 (.) 0 (.) 0 (.0) M. SCREW 0 (.) (.) [. (.)] 0 (.) When mounting, no extra space is needed between units. OUTPUT CODE: CLAMP (top & bottom). (.) 0 (.) DIN RAIL mm wide 0 (.). (.) dia. MTG HOLE (.) deep 0 (.) 0 (.) 0 (.0) M. SCREW 0 0 (.) (.0) [. (.)] 0 (.) When mounting, no extra space is needed between units. KS SPECIFICATIONS ES- Rev.0 Page /
4 TERMINAL ASSIGNMENTS unit: mm (inch) Output Code,, & INPUT RESISTOR (model: REM) (.) shunt resistor attached for current input. Output Code INPUT RESISTOR (model: REM) (.) 0 shunt resistor attached for current input. SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM Output Code,, & Open Collector N.O. (make) Relay INPUT R * Low Drift Amplifier HI ADJ. COM. HI ADJ. Comparator Base Socket * shunt resistor attached for current input. U() POWER V() N.C. (break) Relay SSR KS SPECIFICATIONS ES- Rev.0 Page /
5 Output Code INPUT R * Low Drift Amplifier HI ADJ. COM. HI ADJ. Comparator Ry Ry N.C. N.O. COM N.C. 0 N.O. Relay Protection AC Powered AD DC Powered AD Inductive Load (Coil) Varistor or Spark Quenching Circuit Inductive Load (Coil) Diode, Varistor or CR Circuit COM U() V() POWER Base Socket * shunt resistor attached for current input. Specifications are subject to change without notice. KS SPECIFICATIONS ES- Rev.0 Page /
MODEL: AS4V. Plug-in Signal Conditioners M-UNIT
Plug-in Signal Conditioners M-UNIT DC ALARM (dual or quad alarm trip; field-configurable) Functions & Features Provides relay outputs at preset DC input levels Quad or dual trip Setting and display in
More informationMODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]
Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels CE marking
More informationMODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]
MODEL: MMNV Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels
More informationMODEL: M2VF MODEL: M2VF [1][2] [3][4]
Super-mini Signal Conditioners Mini-M Series SIGNAL TRANSMITTER (high speed response) Functions & Features Converts DC input from a sensor into a standard process signal Isolation between input and output
More informationMODEL: JB2. Plug-in Signal Conditioners M-UNIT
Plug-in Signal Conditioners M-UNIT ANALOG BACK STATION Functions & Features Enables manual loading providing hold/increase/ decrease signals to a device controlled by PID controller When the PID controller
More informationMODEL: W2TS. Mini-MW Series
Space-saving Dual Output Signal Conditioners Mini-MW Series THERMOCOUPLE TRANSMITTER Functions & Features Accepts direct input from a thermocouple and provides a standard process signal 5-segment linearization
More informationMODEL: DA3. Plug-in Signal Conditioners M-UNIT
Plug-in Signal Conditioners M-UNIT D/A CONVERTER (16-bit resolution) Functions & Features Converts parallel digital signal into a DC output BCD, binary, offset binary, two's complement, reflected binary
More informationMODEL: 47LV. Digital Panel Meters 47 Series
Digital Panel Meters 7 Series DC INPUT DIGITAL PANEL METER ( ½ digit, LED display type) Functions & Features ½ digit DC input digital panel meter /8 DIN size Moving average function to suppress the display
More informationJRQ2 ENCODER POSITION TRANSMITTER MODEL. Plug-in Signal Conditioners M-UNIT. (field-programmable; built-in excitation)
Plug-in Signal Conditioners M-UNIT ENCODER POSITI TRANSMITTER (field-programmable; built-in excitation) MODEL JRQ MODEL & SUFFIX CODE SELECTI JRQ MODEL SELECTI Open collector Voltage pulse RS- line driver
More informationMODEL: M2XU MODEL: M2XU [1][2] [3][4]
Super-mini Signal Conditioners Mini-M Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Accepts direct inputs from various sensors and provides a standard process signal I/O types and
More informationMODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series
Digital Panel Meters 47 Series FREQUENCY INPUT DIGITAL PANEL METER (4½ digit, LED display type) Functions & Features 4 ½ digit digital panel meter 1/8 DIN size Accepts a pulse train input to measure rotation
More informationMODEL: M2SES SEN TRONIC AG [3] OUTPUT
Super-mini Signal Conditioners Mini-M Series HIGH/LOW SELECTOR Functions & Features Monitors two DC input signals and transmits an output signal proportional to the higher or lower input CE marking UL
More informationMODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value.
Super-mini Signal Conditioners Mini-M Series FREQUENCY TRANSMITTER (PC programmable) Functions & Features Converts the output from a pulse-type transducer into a standard process signal PC programmable
More informationMODEL: M2DYS SEN TRONIC AG
Super-mini Signal Conditioners Mini-M Series CURRENT LOOP SUPPLY Functions & Features Powers a 20 ma DC current loop Short circuit protection Applicable to smart transmitters CE marking UL approval Typical
More informationMODEL: W2DYS SEN TRONIC AG. Mini-MW Series
MODEL: WDYS Space-saving Dual Output Signal Conditioners Mini-MW Series CURRENT LOOP SUPPLY Functions & Features Powers a 0 ma DC current loop Short circuit protection Applicable to smart transmitters
More informationMODEL: RPPD. Plug-in Signal Conditioners M-UNIT. [2] INPUT 2 Must be the same code as the one chosen for Input 1.
MODE: RPPD Plug-in Signal Conditioners M-UNIT PUSE ISOATOR (built-in excitation; rotary encoder use) Functions & Features Galvanically isolating two pulse rate signals from a rotary encoder Various outputs
More informationMODEL: JPR2. Plug-in Signal Conditioners M-UNIT
MODE: JPR Plug-in Signal Conditioners M-UNIT PUSE SCAER (field-programmable; built-in excitation) Functions & Features Converts pulse rate into convenient engineering unit for display on a totalizing counter
More informationMODEL: 48NDV. Bargraph Indicators 48N Series
Bargraph Indicators 8N Series BARGRAP INDICATING AAR (with -digit digital meter) Functions & Features Displays a process variable in graphic bargraph of ED segments Clear -digit digital meter Provides
More informationMODEL: 48NAV. Bargraph Indicators 48N Series. [3] MOUNTING DIRECTION V: Vertical H: Horizontal
Bargraph Indicators 8N Series BARGRAP INDICATING AAR Functions & Features Displays a process variable in graphic bargraph of ED segments Provides max. alarm contact outputs ulti-color indicator IP front
More informationMODEL: M6SXU MODEL: M6SXU [1][2] [3][4]
Tension-Clamp Ultra-Slim Signal Conditioners M6S Series UNIVERSAL TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection Universal input (mv, V, ma, T/C, RTD and potentiometer)
More informationMODEL: M2EXT. Super-mini Signal Conditioners with Display Mini-M M2E Series
Super-mini Signal Conditioners with Display Mini-M ME Series THERMOCOUPLE TRANSMITTER (PC programmable) Functions & Features Accepts direct input from a thermocouple and provides a linearized process signal
More informationMODEL: 20VS2-02. Hybrid IC Isolation Amplifiers 20 Series
MODEL: 0VS-0 Hybrid IC Isolation Amplifiers 0 Series ISOLATION AMPLIFIER (-port isolation) Functions & Features Being used for printed wiring board installation High-linearity Low power consumption Isolating
More informationMODEL: M6SXT. POWER INPUT DC Power R: 24 V DC
Tension-Clamp Ultra-Slim Signal Conditioners M6S Series THERMOCOUPLE TRANSMITTER (PC programmable) Functions & Features Maintenance-free tension clamp connection 5.9-mm wide ultra-slim design Low profile
More information[3] MOUNTING DIRECTION
Bargraph Indicators N Series BARGRAPH INDICATOR Functions & Features Displays two process variables in dual graphic bargraphs of LED segments Single and dual bargraphs IP front cover plate is easily replaced
More informationMODEL: 48NDVD. Bargraph Indicators 48N Series
Bargraph Indicators 8N Series BARGRAP INDICATING AAR (with -digit digital meter; with -wire transmitter excitation) Displays a process variable in graphic bargraph of ED segments in proportion to a -wire
More informationMODEL: M1EXT. with Display M1E Series
2 Channel Super-mini Signal Conditioners with Display M1E Series THERMOCOUPLE TRANSMITTER (2 channels, PC programmable) Functions & Features Accepts direct input from a thermocouple and provides a linearized
More informationBASIC FEATURES C %RH. Shimaden, Temperature and Humidity Control Specialists. CP3701: Thermocouple Temperature Converter
Shimaden, Temperature and Humidity Control Specialists C %RH CP3701: Thermocouple Temperature Converter CP3702: R.T.D. Temperature Converter CP3703: mv DC-DC Converter CP3704: V/mA DC-DC-Converter CP3705:
More informationMODEL: R1C-GH. Remote I/O R1X Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)
Remote I/O R1X Series THERMOCOUPLE & DC INPUT MODULE (16 points; CC-Link Ver.1.1/Ver.2.) Functions & Features 16-point thermocouple or DC inputs CC-Link interface CC-Link Version 1.1 and 2. can be switched
More informationMODEL: DAST-20. Telemetering System
MODEL: DAST-0 Telemetering System TELEMETERING SYSTEM Functions & Features Small-scale telemetering system Lightning arrester protecting telephone circuit standard Approved of Technical Requirements Compliance
More informationJPQ2 PULSE ACCUMULATOR
INSTRUCTION MANUAL PULSE ACCUMULATOR (field-programmable; built-in excitation) MODEL JPQ JPQ BEFORE USE... Thank you for choosing M-System. Before use, check the contents of the package you received as
More informationMODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With
Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type) Functions & Features Small-size control valve actuator 1/1 high resolution Easy adjustment: electronic limiter at the valve open & closed
More informationMODEL: MRP6. Final Control Elements
Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type) Functions & Features Small-size control valve actuator Electrical positioner incorporated 1/1000 high resolution Easy adjustment: electronic
More informationMODEL: R30US4. Remote I/O R30 Series
Remote I/O R30 Series UNIVERSAL INPUT MODULE (4 points, isolated) Functions & Features 4 points universal input I/O module Isolation between the channels Input range of each channel is individually adjustable
More informationMODEL: M2CEC MODEL: M2CEC-[1][2][3]-[4][5]
Super-mini Signa Conditioners Mini-M Series AC CURRENT TRANSMITTER (camp-on current sensor) Functions & Features Converts an aternating current into a standard process signa Easy-to-insta camp-on type
More informationMODEL: M5CTC. [4] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz) DC Power R: 24 V DC MODEL: M5CTC [1][2][3] [4][5]
MODE: M5CTC Super-mini Termina Boc Signa Conditioners M5-UNIT CT TRANSMITTER (camp-on current sensor) Functions & Features Converts an aternating current into a standard process signa Easy-to-insta camp-on
More informationJTY2 PULSE DURATION RECEIVER BEFORE USE... COMPONENT IDENTIFICATION
INSTRUCTION MANUAL PULSE DURATION RECEIVER (field-programmable; built-in excitation) MODEL JTY JTY BEFORE USE... Thank you for choosing M-System. Before use, check the contents of the package you received
More informationMODEL: R9CWTU. Remote I/O R9 Series. EXTENSION UNIT 1: With connection
Remote I/O R9 Series MULTI POWER MOITORIG UIT (Clamp-on current sensor CLSE, CC-Link) Functions & Features Multi Power Monitoring Unit for CC-Link. By using clamp-on current sensors, there is no need of
More informationMODEL: M3LU. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC
Space-saving Signal Conditioners M-UNIT Series UNIVERSL TRNSMITTER (field- and PC-configurable) Functions & Features Universal input: mv, V, m, T/C,, resistance and potentiometer Easy One-Step Cal calibration
More informationMODEL: M3LU2. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC
MODEL: MLU Space-saving Signal Conditioners M-UNIT Series UNIVERSL TRNSMITTER (field- and PC-configurable) Functions & Features Universal input: mv, V, m, T/C,, resistance and potentiometer Easy One-Step
More informationGeneral Specifications
General Specifications GS 77J01Q08-01E Model VJQ8 Pulse to Analog Converter (Multi-function) (Isolated Single-output and Isolated Dual-output Types) General This plug-in type pulse to analog converter
More informationEconomical Digital Indicators For Process and Electrical Measurement
Economical Digital Indicators For Process and Electrical Measurement DP18 Series Panel Punches Available DP18-P5, 4 to 20 ma input. DP18-EC, thermocouple input visit omega.com/thermocouple for thermocouples.
More informationGeneral Specifications
General Specifications GS 77J04H0-0E Model MH Isolator (Free Range Type) General The MH is a plug-in type isolator that converts DC current or DC voltage signals into isolated DC current or DC voltage
More informationMODEL: WL40MW1F. Wireless I/O WL40F Series
Wireless I/O WL40F Series WIRELESS GATEWAY (Modbus-RTU Transparent 900MHz Band Wireless Device (child device)) FUTIONS & ATURES This unit Incorporates 900MHz band wireless module. Works as a gateway between
More informationMODEL: DLS. Telemetering System
POW RUN SA SA RT RU MODEL: DLS Telemetering System TELEMETERING UNIT Functions & Features Interfacing remote I/O devices with a modem for a telemetering system Process I/O (.0) [] POWER INPUT AC Power
More informationDP2000 ORDERING GUIDE To Order MODEL NO.
1 8 DIN VERSATILE PROCESS MONITORS CONFIGURABLE DP2000-S, 1 8 DIN meter, shown smaller than actual size. DP2000 Series Complete with Input Board RoHS 2 Compliant DP2000-J1, with TJ36-ICSS-116G-12, transition
More informationMODEL: VOS-ER. [4] LEVER POSITION 1: Upper side 2: Lower side. Position Sensors
Position Sensors 2-WIRE POSITION TRANSMITTER (flameproof, rotary motion type) Functions & Features Differential transformer incorporated Light weight and compact design High resolution Zero & Span adjustable
More informationMODEL: R3-RS8A. Remote I/O R3 Series. RTD INPUT MODULE (high accuracy, 8 points, isolated) MODEL: R3-RS8A[1][2]
MODEL: R-RS Remote I/O R Series INPUT MODULE (high accuracy, points, isolated). (.0) 0 (.) 0 (.) mm (inch) MODEL: R-RS[][] ORDERING INFORMTI Code number: R-RS[][] Specify a code from below for each []
More informationPPD COMPONENT IDENTIFICATION BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PULSE ISOLATOR MODEL. (built-in excitation)
INSTRUCTI MANUA PUSE ISOATOR (built-in excitation) MODE PPD BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you have any
More informationMODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT
Space-saving Two-wire Signal Conditioners B3-UNIT 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe) Functions & Features Universal input: mv, V, T/C, RTD, resistance, potentiometer
More informationTimers GE1A. GE1A Series ON Delay Timers Single Function
Key features: DPDT or SPDT + instantaneous SPDT 8-pin, octal base 8 time ranges Repeat error ±0.2% maximum Large, clear knob for easy setting Instant monitoring of operational status by LED indicators
More information20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V
20 AMP POWER RELAY HG RELAYS a 3 1.4 5 RoHS Directive compatibility information http://www.nais-e.com/ a.0 50.0 1.99 8.0 2. FEATURES Large capacity 20 A 250 V AC resistive and 1.5 kw 3 phase 220 V AC motor
More informationMODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With
Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE
More informationEnclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI
General-purpose Relay CSM_GR-_-S_DS_E Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped
More informationn FRONT PANEL CONFIGURATIONS
INSTRUCTION MANUAL VALVE POSITIONER (for LonWorks; built-in SSR) MODEL MEXL MEXL BEFORE USE... Thank you for choosing M-System. Before use, check the contents of the package you received as outlined below.
More informationMODEL: MRP6D. POWER INPUT DC Power R: 24 V DC. Final Control Elements
Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type; DeviceNet) Functions & Features Small-size control valve actuator Direct connection to DeviceNet capable PLC and other devices on the same
More informationRatchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj
Ratchet Relay Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation Each contact in the double-pole contact mechanism performs alternate make-brake operation at each pulse input
More informationHG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS
20 AMP POWER RELAY RELAYS a 3 1.4 5 a.0 50.0 1.99 8.0 2. FEATURES Large capacity 20 A V AC resistive and 1.5 kw 3 phase 220 V AC motor loads High contact reliability after long use Usable with direct soldering,
More informationGT5Y Series ON Delay Timers. UL, c-ul Listed File No. E V AC, 3A 30V DC, 3A 220V AC, 0.8A 30V DC, 1.5A 660VA AC 90W DC 176VA AC 45W DC
TY Series TY Series ON Delay Key features of the TY series include: PDT, 3A or DPDT, A contacts time ranges Repeat error ±0.2% maximum Control settings by hand or screwdriver Power ON and timing out LED
More informationModel Number Structure
General-purpose Relay MK-I/-S Electromechanical Relays Exceptionally Reliable General-purpose Relay Features Mechanical Indicator/Push Button Breaks relatively large load currents despite small size. Long
More informationProcess displays For standard signals, temperature, resistance measurement
Features Inputs: Voltage ±10 V, ±200 V / Current ±20 ma / thermocouples J,K,T,N,Pt100,Pt1000 / resistance measurement / potentiometer Display range can be linearised Two limits output Min, Max functions
More informationWJM POTENTIOMETER TRANSMITTER BEFORE USE... COMPONENT IDENTIFICATION POINTS OF CAUTION INSTRUCTION MANUAL MODEL. (field-programmable)
INSTRUCTION MANUAL POTENTIOMETER TRANSMITTER (field-programmable) MODEL WJM BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.
More informationAbsolute Process Instruments
Strain Gauge, Load Cell, Bridge Current Switches and Transmitters Amplify, alarm strain gauge sensor signals Economical sensors for current out-of range alarms or monitoring current levels APD 1520 APD
More informationOMRON MK-I / -S RELAY
Issued April 0 0 DATA SHEET OMRON MK-I / -S RELAY Based on OMRON Datasheet General-purpose Relay MK-I/-S 0 Exceptionally Reliable General-purpose Relay Features Mechanical Indicator/Push Button Breaks
More informationGeneral-purpose Relay
General-purpose Relay Exceptionally Reliable General-purpose Relay Features Mechanical Indicator/Push Button Breaks relatively large load currents despite small size. Long life (minimum 0,000 electrical
More informationRT-3 UNIT RELAY 4-POINT TERMINAL
Slim, Space-saving, -point Unit Relay RT-3 UNIT RELAY -POINT TERMINAL [PA Relay type, PhotoMOS Power (Voltage sensitive type)] RT-3 Unit relay -point Terminal [PA relay, PhotoMOS Power (Voltage sensitive
More informationIDEC RJ22 Series Slim Power Relays (Bifurcated Contacts)
IDEC RJ22 Series Slim Relays (Bifurcated Contacts) Phone: 00.94.042 - Fax:.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com RJ Series Slim Relay Plug-in Terminal (Bifurcated Contacts) High contact
More informationRelays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.
RFV Key features: Compact and EN compliant RFV force guided relays Force guided contact mechanism (EN00 Type A TÜV approved) Contact configuration -pole (NO-NC, 3NO-NC) 6-pole (NO-NC, NO-NC, 3NO-3NC) Built-in
More informationMODEL: 27HU 27-UNIT MODEL: 27HU [1][2]
Head-mounted Two-wire Signal Conditioners 7-UNIT -WIRE UNIVERSL TEMPERTURE TRNSMITTER (HRT communication) Functions & Features Universal input: DC mv, T/C, RTD and resistance High accuracy HRT communication
More informationNo mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm.
Series Digital LCD Timer DIN W48 H48mm Features Power supply : 4-4VAC 5/6Hz, 4-4VDC universal Easy to switch Up/Down mode programmable output modes and timing ranges () Selectable function by front digital
More informationGeneral Specifications
General Specifications GS J0X02-01E WX2 Series Computing Units (Variable/Fixed Software Type) Moving Average Unit, Dead Time Unit, Velocity Unit, First Order Lug Unit, First Order Lead Unit, Velocity Limiter,
More informationModel Number Structure
General-purpose Relay G2RS-(S) Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped
More informationCP RELAYS POWER TYPE. TYPICAL APPLICATIONS Defoggers, Ignitions, Heaters, Accessories, Powered windows, etc. ORDERING INFORMATION TYPES
High Carrying Current Type Miniature Low Profile Automotive Relay CP RELAYS POWER TYPE Sealed 13.1 14.1 9..374 FEATURES Maximum carrying current of 3 A (4 mw type, 1 V applied)
More informationModel Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models
Solid-state Power OFF-delay Timer H3DE-H Timers Two delay-time models available. 0.1 to 12 seconds (S Series) 1 to 120 seconds (L Series) Covers wide range of supply voltage. Model Number Structure Model
More informationDetails on the New G2RS
New G2RS Series The G2RS Space-saving Power Plug-in Relay has a mechanical indicator and nameplate as standard features. A relay with a lockable test button is also available. Details on the New G2RS Overview
More informationPARM-SIZED, 16-CHANNEL RELAY TERMINALS
Pressure connector connect type Wire-direct connect type PARM-SIZED, -CHANNEL RELAY TERMINALS FEATURES Compact, space-saving design: The Relay Terminal with I/O channels measures only (W) (D) (H) mm (W).
More informationDistributed by: www.jameco.com -8-83-22 The content and copyrights of the attached material are the property of its owner. VDE TV-, AMP ( Form A) Power Relay HE RELAYS.299 3.8.9 RoHS Directive compatibility
More informationOver or Under Current. Over and Under Current Monitor. Current Transducer. Current Indicator. DIN Rail Mounting Current Monitors
Selection Guide...8.2 Over or Under ECS... 8.4 TCS... 8.8 Over and Under Monitor ECSW... 8.6 Transducer TCSA... 8.10 DCSA... 8.12 Indicator LCS... 8.14 LPM... 8.14 DIN Rail Mounting CM-SFS CM-SRS.1 CM-SRS.2
More informationUNIQUELY DESIGNED RELAY WITH HIGH SENSITIVITY. UL File No.: E43149 CSA File No.: LR26550
UNIQUELY DESIGNED RELAY WITH HIGH SENSITIVITY K-RELAYS.0 a UL File No.: E3 CSA File No.: LR2550.0.8 00 times more reliable than similar designs Extra long life Mechanical: more than 0 8 operations Electrical
More informationDistributed by: www.jameco.com 1-8-81-44 The content and copyrights of the attached material are the property of its owner. SLIM POLARIZED RELAY TN RELAYS.551. 9.8.86 FEATURES Small header area makes higher
More informationRT-3 UNIT RELAY 4-POINT TERMINAL
Slim, Space-saving, -point Unit Relay RT-3 UNIT RELAY -POINT TERMINAL [PA-N Relay type, PhotoMOS Power (Voltage sensitive type)] -point Terminal [PA-N relay, PhotoMOS Power (Voltage sensitive type)] Mountable
More information6mm Interface Relays RV8 Series
6mm Interface Relays RV8 Series PRODUCT DESCRIPTION Electromechanical C1D2 (screw terminal) Solid State (spring clamp) IDEC 6mm interface relays provide a compact solution for general purpose relay requirements.
More informationRelays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:
RU Series Universal Relays Key features: Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator
More informationE2F. Cylindrical Proximity Sensor in Plastic Housing. Applications. Ordering Information. Sensors. Accessories (Order Separately)
Cylindrical Proximity Sensor in Plastic Housing High quality full body plastic housing for high water proof requirements Polyarylate housing for light chemical resistance Applications Detection of bottle
More informationSLIM COMPACT SAFETY RELAY
SLIM COMPACT SAFETY RELAY SF-RELAYS Slim type Max. 24.945 Max. 24.945 Max. 4.575 Max. 5.969 Max. 3.52 Max. 3.52 mm inch FEATURES Forcibly guide contact structure (EN525 ClassA TÜV recognized) Slim profile
More informationModel Number Structure
Single-phase Voltage Relay CSM DS_E_3_1 Ideal for voltage monitoring for industrial facilities and equipment. Monitor for overvoltages or undervoltages. Manual resetting and automatically resetting supported
More informationFuzzy Temperature Controllers E5AF
Fuzzy Temperature Controllers 1/4 DIN Controller Combines Fuzzy and PID Control For Fast Response to Process Disturbances Advanced PID control provides optimal response during start-up and steadystate
More informationRelays & Sockets RY/RM RY/RM Series Miniature Relays. Part Number Selection
RY/RM Series Miniature Relays Key features: RY (A), RY (A), RM (A) General purpose miniature relays A or A contact capacity Wide variety of terminal styles and coil voltages meet a wide range of applications
More informationPalm-sized, 16-channel Relay Terminals
Palm-sized, -channel Relay Terminals RELAY TERMINAL FEATURES. Possible to select relay for use in the relay terminal in accordance with load. [Mountable relay: PA relay and Power PhotoMOS (voltage sensitive
More informationSolid-State Digital Counter H7AN
Solid-State Digital Counter Preset and Totalizing Counters with Up to 8-Digit LED Displays Draw-out construction allows setting, servicing without disconnecting wiring Choose from selectable UP/DOWN or
More informationTimers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range
GT3A Key features: 4 selectable operation modes on each model External start, reset, and gate inputs Panel mount or socket mount Large variety of timing functions and output status indicating LEDs UL,
More informationCoaxial Switch. Ordering Information. High-frequency, High-capacity Coaxial Switch Supporting Bandwidth to 26.5 GHz. Model Number Legend:
Coaxial Switch High-frequency, High-capacity Coaxial Switch Supporting Bandwidth to 26.5 GHz Models supporting bandwidth of 26.5 GHz achieve superior high-frequency characteristics, such as an isolation
More informationDIGEM f 96 x 48 EK. Applications. Description
3-349-002-03 1/7.98 Front panel dimensions: 96 x 48 mm LED display: red or green, 14 mm high Max. display range: 19 999 to + 32 765 Modular connectors for flexible use Simple adjustments at front panel
More informationMY-GS. Miniature Power Relays. Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays.
Miniature Power Relays CSM DS_E_1_1 Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays Relays with AC and DC coils have different colors of operating indicators
More informationAdjustable Digital Process Instrument MDK480
Description The adjustable Digital Process Instrument MDK480 is designed to measure and display process variables in industrial applications.the instrument is panel mounted with front frame dimensions
More information30 AMP POWER RELAY WITH SPACE SAVING DESIGN
VDE 3 AMP POWER RELAY WITH SPACE SAVING DESIGN JH-RELAYS 2..2 3.. FEATURES Many safety-oriented characteristics incorporated Contact gap: more than 3 mm. inch for Form A and 2 Form A Breakdown voltage
More informationPID CONTROLLERS LT SERIES
PID CONTROLLERS LT SERIES The Axis family of microprocessor based controllerscombine a high degree of functionality and reliability at a very low price, in 4 different formats : 1/16 DIN, 1/8 DIN, 1/ 4
More information+GF+ SIGNET Temperature Transmitter Instructions
GF SIGNET 80- Temperature Transmitter Instructions ENGLISH -80.090- B-/00 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal
More informationFeatures. Measuring and Monitoring Relays K8AB Series. Cut by 50% Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22.
Measuring and Monitoring Relays K8AB Series Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22.5 mm Eight slim models featuring a variety of innovative new functions. Single-phase
More informationMODEL: R7G4HML3. Remote I/O R7G4H Series MECHATROLINK I/O MODULE (MECHATROLINK-III)
MODEL: RGHML3 Remote I/O RGH Series MECHATROLINK I/O MODULE (MECHATROLINK-III) ( V open collector input) PAA: Encoder input (speed / position) point ( V open collector input) STYVS: Self-synch input, DC
More informationWHEN A PLC IS TOO MUCH, AND SPACE FOR
WHEN A PLC IS TOO MUCH, AND SPACE FOR A RELAY SEQUENCE CIRCUIT IS TOO LITTLE Pattern Selector 59 2.33 66 2.6 70 2.75 No programming required Select from among 15 preset patterns Wiring far simpler than
More information