CORR/GUARD. Viton diameters; integral sleeve design.
|
|
- Johnathan Newton
- 5 years ago
- Views:
Transcription
1
2 ORR/GUR - 3 diameters; integral sleeve design. Intergal Sleeve connections are formed to fit with precision at each connection. ll-welded construction provides liquid-tight performance and clean appearance. Vee and connectors are engineered for exact fit around flanges, providing a strong, liquid-tight connection. Viton
3 ORR/GUR TLE OF ONTENTS GENERL INFORMTION... 3 OES & STNRS... 3 PROUT INFORMTION... 4 PPLITION INFORMTION... 5 OMPONENTS IMENSIONL T/ WRRNTY GENERL INFORMTION Pertinent information is consolidated in this publication to assist you with application information, codes and standards, dimensional information, support requirements and other data of special interest. It is our goal to enable you to select the proper product to meet the requirements of your project confidently and efficiently. For additional information you may contact us via: Web Site: Telephone: Toll Free Phone: Fax: info@metal-fabcommercial.com omplete information for proper and safe installations is found in the Metal-Fab Installation Instructions. (Literature No. L251) This design manual contains data to assist in the proper selection, design, and layout of venting systems using Metal-Fab models: FS ouble Wall Special Gas Vent FSSW Single Wall Special Gas Vent FS-1 ouble Wall Insulated Special Gas Vent OES N STNRS orr/guard is listed to UL 13, Standard for Venting Systems for Gas-urning ppliances, ategories II, III, IV and UL S3. These requirements cover venting systems intended for venting ategory II, III, and IV gas-burning appliances as defined by the Standard for Gas-Fired entral Furnaces (except irect Vent entral Furnaces), NSI Z21.4 and the National Fuel Gas ode, NFP 54. Venting systems covered by these requirements are intended to be used with ategory II, III, and IV appliances that have been installed in accordance with NFP 54, the I International Mechanical ode, the IPMO Uniform Mechanical ode, and local codes. orr/guard vent material is L2-4 superferritic stainless steel. This vent is intended for use wherever appliance manufacturers specify superferritic stainless steel as the required vent material and, vent gas temperatures do not exceed those listed in the Metal-Fab Installation Instructions and the pplication section of this manual. Venting system design may be limited by appliance performance. onsult appliance installation instructions to determine limitations such as maximum horizontal length, maximum vertical height, elbow and offset limitations, and number of appliances permitted in a common vent. Model FSSW chimney liner systems, sizes " thru 3" diameter is intended for use in masonry chimneys used to vent ategory II, III, or IV gas-fired appliances. FSSW is suitable for installation in masonry chimneys having no clearance between combustible construction and the outer chimney surface. Model PSW chimney lining system, sizes " thru 3" diameter are intended for use in masonry chimneys used to vent gas fired appliances equipped with draft hoods; appliances equipped with draft hoods; appliances intended for use with Type gas vents. PSW is suitable for installation in masonry chimneys having no clearance between combustible construction and the outer chimney surface
4 ORR/GUR PROUT INFORMTION orr/guard " " iameters To determine metric dimensions: multiply inches X 25.4 ESRIPTION Max Operating Temperature Max Operating Pressure learance to ombustibles ENLOSE (2 ) learance to ombustibles ENLOSE HORIZONTL learance to ombustibles UNENLOSE HORZ. or 550º F (2 ) JOINT ONNETION Flue Material Thickness asing Materials OULE WLL SINGLE WLL 550º F (2 ) 15" w.g. 550º F (2 ) 15" w.g. 1" an Not e Enclosed with ombustible Material an Not e Enclosed with ombustible Material an Not e Enclosed with ombustible Material 1" 2" SLEEVE P0 Sealant Required SLEEVE P0 Sealant Required L " L " Std- luminized Steel 0.01" Opt 430 Stainless Steel 0.0" Opt 304 Stainless Steel 0.0" Opt 31 Stainless Steel 0.0" Not pplicable orr/guard " " iameters To determine metric dimensions: multiply inches X 25.4 ESRIPTION Max Operating Temperature Max Operating Pressure learance to ombustibles ENLOSE (2 ) learance to ombustibles ENLOSE HORIZONTL learance to ombustibles UNENLOSE HORZ. or 550º F (2 ) JOINT ONNETION Flue Material Thickness asing Materials Thickness OULE WLL SINGLE WLL 550º F (2 ) 15" w.g. 550º F (2 ) 15" w.g. 1" an Not e Enclosed with ombustible Material an Not e Enclosed with ombustible Material an Not e Enclosed with ombustible Material " 1" = 2" " " = 3" " 1" = 3" " " = 4" SLEEVE P0 Sealant Required SLEEVE P0 Sealant Required L L Std- luminized Steel Opt 430 Stainless Steel Opt 304 Stainless Steel Opt 31 Stainless Steel 0.0" Not pplicable orr/guard 2" 3" iameters To determine metric dimensions: multiply inches X 25.4 ESRIPTION Max Operating Temperature Max Operating Pressure learance to ombustibles ENLOSE (2 ) learance to ombustibles ENLOSE HORIZONTL learance to ombustibles UNENLOSE HORZ. or 550º F (2 ) JOINT ONNETION Flue Material Thickness asing Materials Thickness OULE WLL SINGLE WLL 550º F (2 ) 15" w.g. 550º F (2 ) 15" w.g. 2" an Not e Enclosed with ombustible Material an Not e Enclosed with ombustible Material an Not e Enclosed with ombustible Material 2" 30" = 4" 32" 3" = 5" 2" 30" = 5" 32" 3" = " SLEEVE P0 Sealant Required SLEEVE P0 Sealant Required L L Std- luminized Steel Opt 430 Stainless Steel Opt 304 Stainless Steel Opt 31 Stainless Steel 0.035" Not pplicable 4
5 ORR/GUR PPLITION INFORMTION ESIGN ONSIERTIONS NOTE: For dditional Information See orr/guard Installation Instructions, No. L251 vailable at: When venting gas appliances always consult the appliance installation instructions. Horizontal runs, elbows, offsets, vertical height, may be limited by appliance performance specifications. Horizontal runs must slope a minimum of ¼" : " (mm-305mm). Neutral or negative pressure systems must slope upward away from the appliance. Positive pressure within the vent may slope upward or downward. Provide for condensate drainage where required. Vertical runs are directional-specific and must be properly supported. Supports are required above every offset to prevent vertical loading on elbows. SIEWLL EXHUST MULTI-UNIT EXHUST P MITER UT MLE P STORM OLLR WLL THIMLE FLSHING HORIZONTL RIN SETION OR TEE WITH TEE P ORR/GUR PIPE RIN SETION OR TEE WITH TEE P RIN TUE PPLINE PTER PPLINE PTER OOT TEE WITH RIN TEE P ORR/GUR PIPE RIN TUE PPLINE PTER OMPONENTS orr/guard is identified as FSSW and FS designating the integral sleeve design incorporated in " 3" diameters. orr/guard is available in a multitude of material options to address your unique applications. To facilitate the ordering process we have a designated TO code which allows you to onfigure To Order. The TO code consists of three (3) designators. The 1st identifies flue material; the 2nd identifies outer casing material, and the 3rd, a 0 or 1 indicates if the product is "air" or "ceramic fiber" insulated. Selections FLUE SING L2-4 STINLESS LUMINIZE STEEL STINLESS STINLESS 31 STINLESS INSULTION 0 ir Insulated 1 eramic Insulated Example: You have selected a " diameter pipe section, 3" in length, double wall construction, with a 430 stainless casing with ceramic fiber insulation. The part number is (diameter)-fs (sleeved orr/ Guard) 3" length. dditionally, you have selected the TO code: (L2-4 Stainless Flue) - 3 (430 Stainless asing) -1 (eramic Insulated). The complete designation is: FS3 31. ORROSION RESISTNE orr/guard products are designed for use on today s highly efficient condensing appliances. L2-4, a Superferritic Stainless Steel was the first steel to successfully exceed the requirements of UL 13, Standard For Venting Systems For Gas-urning ppliances, ategories II, III, and IV." It is considered the benchmark for condensing flue materials
6 FS/FSSW OMPONENTS " 3" IMETERS SINGLE WLL OILER PTER (S) Flow Resistance K = same as pipe. "- ": = " (1) 2"- 3": = " Used to attach pipe to straight shank outlets. ttaches around exterior of collar. FS S includes closure band. Not required on FSSW. * * * * SING EN LOSURE SINGLE WLL OILER PTER INSIE (SI) " " iameters Flow Resistance K = same as pipe..00 Used on vertical outlets when appliance incorporates condensate drain. NOTE: Not available above ". SING EN LOSURE REUER OLLR (R) " " iameters Flow Resistance K = same as pipe. : Inlet iameter : omponent Length = " : Outlet iameter ** Used to attach pipe to an outlet source smaller than pipe diameter. ** * * * Specify dimensions when ordering. Example: FSR * * * * SING EN LOSURE FEMLE FLNGE ONNETOR (FF) " " iameters Flow Resistance K = same as pipe..00 Used to transition from FS to G NOTE: Not available in " & " diameters. MLE FLNGE ONNETOR (MF) " " iameters Flow resistance K = same as pipe. Used to transition from G to FS NOTE: Not available in " & " diameters
7 FS/FSSW OMPONENTS " 3" IMETERS FEMLE TO FEMLE PTER (F) " " iameters Used to change direction of slope..5 MLE TO MLE PTER (M) " " iameters Used to change direction of slope..5 LST GTE (G) FGSWG " " iameters Used for balancing pressures in a common vent system. Note: vailable in single wall only SING EN LOSURE (E) Used as an end cover when transitioning from single wall to double wall construction. ttaches to casing with sheet metal screws. Note: 2" - 3" asing End losure clamps around casing bead " 3" iameters " " iameters
8 FS/FSSW OMPONENTS " 3" IMETERS PIPE LENGTHS STRIGHT LENGTH " THRU 3" L PIPE LENGTHS INSTLLE LENGTH (L) L.00" ().5" (1).00" (305).5" (23) 1.00" (45) 1.5" (42).00" ().5" (5) 3.00" () 34.5" (3) PIPE PIPE O.. FSSW FS " " (3) " (1) " () " (3) " (254) " () 11" (2) " (254) " (305) " (305) " (35) " (35) 1" (40) 1" (40) 1" (45) 1" (45) " (50) " (50) " " " () " () 2" (0) 2" (1) 2" (11) 2" (11) 30" (2) 30" (2) 32" (13) 32" (13) 34" (4) 34" (4) 3" () 3" () 3" (5) Flow Resistance K=.4 ( ) for " - 1"(40) diameters Flow Resistance K=.3 ( ) for 1"(45) - 3"() diameters L Flow Resistance K=.25 ( ) L = pipe length in feet = pipe diameter in inches NOTES: 1. educt 1-1/4" for installed length. 2. ustom lengths available, contact factory. L FS STRIGHT LENGTH VRILE LENGTH (VL) " " iameters L Flow Resistance K =.4( ) L = pipe length in feet = flue diameter Used to fill gaps between standard length components. oes not allow for thermal expansion. L INSTLLE LENGTH (L) UP VL Minimum: Maximum: " () "
9 FS/FSSW OMPONENTS " 3" IMETERS VRILE LENGTH (VL/VL) 2" 3" iameters L Flow Resistance K =.4( ) L = pipe length in feet = flue diameter Used to fill gaps between standard length components. oes not allow for thermal expansion. L INSTLLE LENGTH (L) VL VL " (1) " (254) Minimum: Maximum: UP " (1) " TPERE INRESER (TI) 3" iameter Used to transition from G to FS. 3.00" ().00". UP imensions in inches (mm). 3FSTI EENTRI TPERE INRESER (EI) 4" 5" iameters Used to transition from G to FS. 4.00" (2).00" 1.00" (25) 5.00" ().00" 0.50" (13). imensions in inches (mm). TPERE INRESER (TI) 2 Flow Resistance K =.51 [1-( ) ] 2 4 ( ) = Inlet iameter = Outlet iameter = Installed Length See Table UP NOTE: ½ Step = 1" increase in diameter; 1 Step = 2" increase in diameter Steps Length ½-3 3½- 15" (31) " (50) When ordering, specify inlet and outlet diameters with inlet diameter first. Example: FSTI
10 FS/FSSW OMPONENTS " 3" IMETERS EENTRI TPERE INRESER (EI) 2 ] Flow Resistance K =.51 [1-( ) 2 4 ( ) = Inlet iameter = Outlet diameter = Installed Length See Table NOTE: ½ Step = 1" increase in diameter; 1 Step = 2" increase in diameter Steps 2½ " (31) 21" (534) 2" () UP Length ½-2 When ordering, specify inlet and outlet diameters with inlet diameter first. Example: FSEI TPERE REUER (R) " " iameters 2 2 Flow Resistance K =.1 [1-( ) ] = Inlet iameter 4 ( ) = Outlet iameter UP = Installed Length See Table NOTE: ½ Step = 1" decrease in diameter; 1 Step = 2" decrease in diameter Steps -3½ 3-½ Length " (50) 15" (31) When ordering, specify inlet and outlet diameters with inlet diameter first. Example: FSR EENTRI REUER (ER) " " iameters 2 2 Flow Resistance K =.1 [1-( ) ] = Inlet iameter = Outlet diameter UP 4 ( ) = Installed Length See Table NOTE: ½ Step = 1" decrease in diameter; 1 Step = 2" decrease in diameter Steps -4½ 4-2½ 2-½ Length 2" () 21" (534) 15" (31) When ordering, specify inlet and outlet diameters with inlet diameter first. Example: FSER
11 FS/FSSW OMPONENTS " 3" IMETERS 15 ELOW (15L) 30 ELOW (30L) Flow Resistance K = 0.0 O Flow Resistance K = 0. O Offset istance: O = 2 x x 0.25 Offset istance: O = 2 x x 0.5 Offset distance with pipe length between elbows: O = (2 x + pipe length) x 0.25 Offset distance with pipe length between elbows: O= (2 x + pipe length) x PIPE PIPE FSSW / FS FSSW / FS " 4.5" (11) " 5.00" () " (1) 4.3" (11) " (1) 5.13" (130) " (3) 4." (11) " (3) 5.25" (133) " () 4.5" (1) " () 5.3" (13) " (254) 4." (4) " (254) 5.50" (0) " (305) 5.00" () " (305) 5.5" () " (35) 5.13" (130) " (35).0" (154) 1" (40) 5.25" (133) 1" (40).3" () 1" (45) 5.3" (13) 1" (45).3" (1) " (50) 5.50" (0) " (50)." (15) " 5.3" (3) ".13" (11) " () 5.5" () " ().3" (1) 2" (0).50" (21) 2" (0).50" (21) 2" (11).50" (21) 2" (11).50" (21) 30" (2).50" (21) 30" (2).50" (21) 32" (13).50" (21) 32" (13).50" (21) 34" (4).50" (21) 34" (4).50" (21) 3" ().50" (21) 3" ().50" (21) imensions in inches (mm). imensions in inches (mm)
12 FS/FSSW OMPONENTS " 3" IMETERS 45 ELOW (45L) 0 ELOW (0L) Flow Resistance K = 0.15 Flow Resistance K: " " = 0.3 " 1" = 0.42 " 2" = " 3" = 0.2 Offset istance: O = 2 x x 0.0 Offset istance with pipe length between elbows: O = (2 x + pipe length) x 0.0 Offset istance: O = 2 x o Offset istance with pipe length between elbows: O = 2 x + pipe length O FS0L PIPE PIPE FSSW / FS FSSW / FS " 5.44" (13) "." () " (1) 5.3" (3) " (1).3" (23) " (3) 5." () " (3)." (251) " ().0" (154) " ().3" () " (254).2" (15) " (254)." (2) " (305)." (12) " (305) 11." (302) " (35).13" (11) " (35)." (32) 1" (40).51" (11) 1" (40) 13." (353) 1" (45).4" (2) 1" (45)." (3) " (50).32" (211) " (50) 15." (403) "." (3) " 1." (42) " ().2" (235) " () 1." (454) 2" (0) 11.5" (2) 2" (0) 21.00" (533) 2" (11) 11.5" (2) 2" (11).00" 30" (2) 11.5" (2) 30" (2) 23.00" (54) 32" (13) 11.5" (2) 32" (13).00" () 34" (4) 11.5" (2) 34" (4) 25.00" (35) 3" () 11.5" (2) 3" () 2.00" (0) imensions in inches (mm) imensions in inches (mm).
13 FS/FSSW OMPONENTS " 3" IMETERS OOT TEE (T) " " iameters Flow Resistance K = 0.5 = Pipe = + " = Tap = " E = 5" E NOTES: 1. Specify tap diameter () at time of order. 2. Tap can be reduced by 1-4 steps as standard. OOT TEE W/ RIN (T) " " iameters Flow Resistance K = 0.5 = Pipe = +.35" = Tap = " E E = 2.35" 0.3" O.. NOTES: 1. Specify tap diameter () at time of order. 2. Tap can be reduced by 1-4 steps as standard. 0 TEE (T) Flow Resistance K = 1.25 = Pipe = + " = Tap = 5" NOTES: 1. Specify tap diameter () at time of order. 2. Tap can be reduced by 1-4 steps as standard. 45 TEE (45T) Flow Resistance K = 0.4 Used for low resistance flow into vertical or horizontal run. NOTES: 1. Specify tap diameter () at time of order. 2. Tap can be reduced by 1-4 steps as standard. 3. For dimensional information see tables on pages 23 &
14 FS/FSSW OMPONENTS " 3" IMETERS OULE LTERL (L) 2" 3" iameters Flow Resistance K = 0.4 Used to centrally connect two appliances manifolded into a common chimney. NOTES: 1. Specify tap diameter () when ordering; tap diameter must be less than body diameter. 2. Tap can be reduced by 1-4 steps as standard. 3. For dimensional information see tables on pages 23 &. 0 WYE (0Y) PIPE FSSW / FS 2" (0).3" (23) 1.00" (43) 2" (11).5" ().00" (50) 30" (2).25" (21) 21.00" (533) 32" (13).2" (20).00" 34" (4) 11." (23) 23.00" (54) 3" () 11.50" (22).00" () 2" 3" iameters Flow Resistance K = 0. RIN SETION (S) " " iameters Flow Resistance K = O.. Used to drain rain water or condensation from inside the stack RIN SETION (S) 2" 3" iameters Flow Resistance K = 0.25 Used to drain rain water or condensation from inside the stack. 1" N.P.T. NIPPLE.5" (23) 1.00 (45) 5.3" (13) " " iameters 4.5 (1) LINER 2" 3" iameters RIN TEE P W/ SING EN LOSURE (T) 2.50 (4) " " iameters 0.3" O.. Used as a drain port for rain or condensation (0)
15 FS/FSSW OMPONENTS " 3" IMETERS RIN TEE P W / SING EN LOSURE (T) " 3" iameters Used as a drain port for rain or condensation. 1" N.P.T. NIPPLE SING EN LOSURE TEE P LESS RIN W/ SING EN LOSURE (TN) 2.50 (4) " " iameters Used to close and seal unused port of Tees, Wyes and Laterals (0) TEE P LESS RIN W / SING EN LOSURE (TN) " 3" iameters HNLE Used to close and seal unused port of Tees, Wyes and Laterals. SING EN LOSURE.25 TLL ONE FLSHING (F) Used for flat roof applications. PIPE FSSW/FS ".00" (305).00" () " (1) 13.00" (330) 25.00" (35) " (3).00" (35) 2.00" (0) " () 15.00" (31) 2.00" () " (254) 1.00" (40) 2.00" () " (305) 1.00" (45) 30.00" (2) " (35).00" (50) 32.00" (13) 1" (40).00" 34.00" (4) 1" (45).00" () 3.00" (15) " (50) 2.00" (0) 3.00" () " 2.00" () 40.00" (1) " () 30.00" (2) 42.00" () 2" (0) 32.00" (13) 44.00" (111) 2" () 34.00" (4) 4.00" (11) 30" (2) 3.00" () 4.00" (1) 32" (13) 3.00" (5) 50.00" (0) 34" (4) 40.00" (1) 52.00" (1321) 3" () 42.00" () 54.00" (132) imensions in inches (mm)
16 FS/FSSW OMPONENTS " 3" IMETERS FIXE PITH FLSHING (FPF) NOTE: X=PITH RTE, VILLE RTES 1/-/. Please specify pitch rate with order (2).00 (305) MIN. When ordering, specify pipe diameter followed by pitch rate. Example: FSFPF4 X.00 (305).00 (153)TYP. 2 STORM OLLR (S) = Pipe iameter (O..) 4.00 (2) STK P (/) Flow resistance K = 0.5 Provides partial rain protection. Use of rain Tee ap (T) or rain Section (S) is recommended. PIPE NOTES: lso available with bird screen; order as (). 2"- 3" diameters are custom; please contact factory. (1) 11.00" (2) " (1).50" (2).50" (31) " (3) 11.50" (22).00" (35) 5.00 ".50" " ().5" (3) 15.50" (34) " (254) 13.50" (343) 1.00" (432) " (305).50" (3) 21.00" (533) " (35) 15.50" (34).00" () 1" (40) 1.50" (445) 2.00" () 1" (45) 1.50" (40) 31.00" () " (50).50" (521) 34.00" (4) " 21.50" (54) 3.00" (5) " () 23.50" (5) 41.00" (41) 2" (0) 25.50" (4) 44.00" (111) 2" (11) 2.50" () 4.00" (1) 30" (2) 2.50" (4) 51.00" (5) 32" (13) 31.50" (00) 54.00" (132) 34" (4) 33.50" (51) 5.00" (3) 3" () 35.50" (02) 1.00" (154) imensions in inches (mm)
17 FS/FSSW OMPONENTS " 3" IMETERS EXIT ONE (E) Flow resistance K = 1.25 PIPE Used to increase velocity of exitingflue gases. Provide for moistureremoval with Tee ap or rain Section. ".50" (1) 11.00" () " (50).50" (521) 34.00" " (1).50" (2).50" (31) " 21.50" (54) 3.00" (5) " (3) 11.50" (22).00" (35) " () 23.50" (5) 41.00" (41) PIPE (4) " ().5" (3) 15.50" (34) 2" (0) 25.50" (4) 44.00" (111) " (254) 13.50" (343) 1.00" (432) 2" () 2.50" () 4.00" (1) " (305).50" (3) 21.00" (533) 30" (2) 2.50" (4) 51.00" (5) " (35) 15.50" (34).00" () 32" (13) 31.50" (00) 54.00" (132) 1" (40) 1.50" (445) 2.00" () 34" (4) 33.50" (51) 5.00" (3) 1" (45) 1.50" (40) 31.00" () 3" () 35.50" (02) 1.00" (154) imensions in inches (mm). LOSURE RING (R) = Pipe iameter () Used to attach to flue and shield annular space from the weather when open stack is desired. 2.5 () NOTE: Provide a Tee ap (T) or rain Section (S) for moisture removal. MITER UT MLE (MM) +.00(153) Used for horizontal termination sloping toward the appliance. Standard with bird screen. SING EN LOSURE MITER UT FEMLE (MF) FSMM +.00(153) Used for horizontal termination sloping away from the appliance. Standard with bird screen SING EN LOSURE
18 FS/FSSW OMPONENTS " 3" IMETERS WLL PENETRTOR KIT (WPK) Used for horizontal wall penetrations, designed for non-fire rated walls. (Zinc Plated) 3.00 RITION SHIEL 3.00 FSSWWPK (Single wall) O SING EN LOSURE FSWPK (ouble wall) 3.00 O.. Framing dimension + " RITION SHIEL SING N 1.00 PLTE SUPPORT (PS) Provides vertical or horizontal anchored support. Includes split plates, clamp flanges, and 1/2 closure bands. (Zinc Plated) o not exceed X between supports. " " FSSW X = 0' " " FSSW X= 2" 3" FSSW X = 0' 5' " " FS X= 50' " " FS X= 30' 2" 3" FS X = 0' NOTE: oes not allow for thermal expansion. PIPE FSSW / FS "-" " (1) "-1" " () "- " 11" (2) 2"- 3" " FLUE I. + 1
19 FS/FSSW OMPONENTS " 3" IMETERS FIRESTOP (FS) PIPE FSSW FS " 1.00" (40) 1.00" (40) 1.00" (45) 1.00" (45) " (1) 1.00" (432) 1.00" (432) 1.00" (43) 1.00" (43) " (3) 1.00" (45) 1.00" (45).00" (50).00" (50) " () 1.00" (43) 1.00" (43) 21.00" (533) 21.00" (533) " (254).00" (50).00" (50).00".00" " (305).00".00".00" ().00" () " (35).00" ().00" () 2.00" (0) 2.00" (0) 1" (40) 2.00" (0) 2.00" (0) 2.00" () 2.00" () 1" (45) 2.00" () 2.00" () 30.00" (2) 30.00" (2) " (50) 30.00" (2) 30.00" (2) 32.00" (13) 32.00" (13) " 32.00" (13) 32.00" (13) 34.00" (4) 34.00" (4) " () 34.00" (4) 34.00" (4) 3.00" () 3.00" () 2" (0) 3.00" () 3.00" () 3.00" (5) 3.00" (5) 2" (11) 3.00" () 3.00" (5) 40.00" (1) 40.00" (1) 30" (2) 40.00" (1) 40.00" (1) 42.00" () 42.00" () 32" (13) 42.00" () 42.00" () 44.00" (111) 44.00" (111) 34" (4) 44.00" (111) 44.00" (111) 4.00" (11) 4.00" (11) 3" () 4.00" (11) 4.00" (11) 4.00" (1) 4.00" (1) SSEMLE imensions in inches (mm). NOTE: 2" - 3" (Zinc Plated) WLL N (W) PIPE " 1" iameters FSSW FS For interior use only. o not exceed ' 0" between supports (51) " 5.00" ().0" ().00".0" (230) " (1) 5.50" (0).0" (5).50" (15).0" (25) " (4).00".0" (230).00" (1) 11.0" (21) " ().50" (15).0" (25).50" (11).0" (30) " (254).00" (1) 11.0" (21).00" (4) 13.0 " (332).00" (3) 13.0" (332) " (305).00" () 15.0" (33) " (35) N/ N/.00" (254) 1.0" (434) 1" (40) N/ N/ 11.00" (2) 1.0" (44) imensions in inches (mm)
20 FS/FSSW OMPONENTS " 3" IMETERS WLL SUPPORT (WS) " " iameters PIPE Used to secure the vent to interior and exterior walls, maintaining clearance and providing alignment. o not exceed 30 ft. distance between supports on interior walls. o not exceed ft. between supports on exterior walls. FSSW FS ".00" 5.00" () ".00" (1) 5.50" ".00" (3).00".00" (3) (0).00".00".00" (3) 5.00" ().00" (3) ().00" () 5.50" (254).00" (254).00" (1).00" ().00" (254) ".00" ().50" (15) 11.00" (2) 11.00" (2).50" (15) 11.00" (2) ".00" (254).00" (1).00" (305).00" (305).00" (1).00" (305) ".00" (305).00" (3).00" (35).00" (35).00" (3).00" (35) ".00" (35) 13.00" (330) 1.00" (40) 1.00" (40) 13.00" (330) 1.00" (40) 1" 1.00" (40).00" (35) 1.00" (45) 1.00" (45).00" (35) 1.00" (45) 1" 1.00" (45) 15.00" (31).00" (50).00" (50) 15.00" (31).00" (50) ".00" (50) 1.00" (40).00".00" 1.00" (40).00" ".00" 1.00" (432).00" ().00" () 1.00" (432).00" () ".00" () 1.00" (45) 2.00" (0) 2.00" (0) 1.00" (45) 2.00" (0) imensions in inches (mm) () WLL SUPPORT (WS) 2" 3" iameters PIPE Used to provide vertical support. (Zinc Plated) NOTES: 1. oes not allow for thermal expansion. 2. o not exceed 40' between supports on interior walls. 3. o not exceed ' between supports on exterior walls. FSSW / FS 2" (0) 1.2" (43) 1.00" (45) 2" (11) 1.2" (4) 1.00" (43) 30" (2).2" (5).00" (50) 32" (13) 21.2" (54) 21.00" (533) 34" (4) 23." (5).50" (52) 3" ()." (13) 23.50" (5)
21 FS/FSSW OMPONENTS " 3" IMETERS GUY RING (GR) " " iameters = Flue iameter for FSSW = Flue iameter + 2" for FS NOTE: Guy Ring clamps around outside of pipe. GUY RING (GR) STORM OLLR 2" 3" iameters Guy Ring clamps around flue flange band. HLF LOSURE N GUY RING (ZIN PLTE) HLF LOSURE N HLF NGLE RING (HR) O.. " " iameters Maximum distance between supports or elbows = ' 0" FULL NGLE RING HLF NGLE RING (HR) HLF NGLE RING 2" 3" iameters Used to support horizontal runs. (Zinc Plated) NOTE: Maximum distance between supports or elbows = ' " FULL NGLE RING FULL NGLE RING (FR) HLF NGLE RING 2" 3" iameters Used to provides lateral support for vertical runs. llows pipe movement for thermal expansion. (Zinc Plated) PROUT IMENSIONS Inside Hole enterline FSSW PIPE FS Outside Hole Qty. 2" (0) " () 2.50" () 30.25" () 2" (11) 2" (0) 2.25" (1) 30.50" (5) 32.25" () 30" (2) 2" () 30.25" () 32.50" (2) 34.25" (0) 2 32" (13) 30" (2) 32.25" (1) 34.50" () 3.25" (21) 2 34" (4) 32" (13) 34.25" (0) 3.50" (2) 3.25" (2) 32 3" () 34" (4) 3.25" (21) 3.50" () 40.25" () 32-3" () 3.25" (2) 40.50" (2) 42.25" (3)
22 FS/FSSW OMPONENTS " 3" IMETERS LIFTING RING (LR) Used to support and lower vent assembly into existing chimney NOTE: vailable in single wall only STK SUPPORT SSEMLY (SS) Used to supports vertical stack at floor level. Includes moisture drain. Maximum Supported Height:.3" I. TUING "-" I. 1" NPT NIPPLE 2"-3" I. " " FSSW = 0' " " FSSW = 5' 2" 3" FSSW = 0' " " FS = 50' " " FS = 30' 2" 3" FS = 0' FSSW / FS E = PIPE = " () = 5.5" (0) E = +" (1) E = +"
23 FS/FSSW OMPONENTS " 3" IMETERS ORR/GUR 45MT & L TLE IN INHES " 3" iameters 3FS 34FS 32FS "" "" 30FS "" "" 2FS "" "" 2FS "" "" FS "" "" FS "" "" FS "" "" 1FS "" "" 1FS "" "" FS "" "" FS "" "" "" "" FS FS FS FS "" "" FS TP "" "" "" "" "" "" "" "" "" "" FSSW & FS 45MT & L TLE IN INHES 23
24 FS/FSSW OMPONENTS " 3" IMETERS 3FS 34FS "" "" 32FS "" "" 30FS "" "" 2FS "" "" 2FS "" "" FS "" "" FS "" "" FS "" "" 1FS "" "" 1FS "" "" FS "" "" FS "" "" "" "" FS FS FS FS "" "" FS ORR/GUR 45MT & L TLE IN METRI 153mm 15mm iameters "" "" "" "" "" "" "" "" TP FSSW & FS 45MT & L TLE IN METRI
25 FS/FSSW OMPONENTS " 3" IMETERS JOINT SSEMLY 1. pply continuous bead of sealant ¼ wide at corner of flange and sleeve. 2. Join to next section. 3. Fill the flange vee band with sealant and install around flanges. 4. Gently tap vee band with a soft head mallet while tightening band to assure tight seal. 5. Install casing closure band. (Seal if external to structure to prevent moisture infiltration) SELNT REQUIREMENTS P0 Sealant Flue iameter Tubes / Joint Joints / Tube " 0. 5 " 0. 5 " 0. 5 " " " " " " " " " " /2 32" /2 34" /2 3" /2 WRRNTY LIMITE LIFETIME WRRNTY The Metal-Fab, Inc. thru 3-inch diameter Model FS orr/guard ouble Wall and FSSW orr/guard Single-Wall factory-built gas vent system (the products), when installed in accordance to manufacturer s instructions and when properly and regulary cleaned and maintained, are warranted by Metal-Fab, Inc. under normal use against defects in material or workmanship for as long as the original purchaser owns the vent system. Refer to Metal-Fab Warranty form L21 for complete information and claim procedures, exclusions and limitations. The complete warranty is available at:
26 FS/FSSW OMPONENTS " 3" IMETERS Pressure Rated himney & Vents Generator & Fume Exhaust FSTER. SFER. ETTER....THE METL-F WY
27 FS/FSSW OMPONENTS " 3" IMETERS G Series Factory-uilt Grease uct Systems
28 Litho in U.S.. 1 Metal-Fab, Inc. Form No. L2-2/1 4
ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JEROME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) FAX: (450)
ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JEROME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) 565-6336 FAX: (450)565-6519 www.icc-rsf.com INSTALLATION AND OPERATION INSTRUCTIONS "Model VIP" CHIMNEY TYPE: FACTORY BUILT
More informationRESIDENTIAL TYPE B GAS VENT
TLOGUE SEPTEMER 1998 RESIENTIL TYPE GS VENT TYPE GS VENT SIZING INFORMTION In anada, to calculate -Vent sizing, refer to Gas Sizing harts located in the Natural Gas Installation ode N/G 149.1 and/or the
More informationICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JÉRÔME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) FAX: (450) INSTALLATION AND OPERATION INSTRUCTIONS
ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JÉRÔME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) 565-6336 FAX: (450)565-6519 INSTALLATION AND OPERATION INSTRUCTIONS "IS" CHIMNEY TYPE: SIZE: FACTORY BUILT CHIMNEY FOR
More informationNever fill any required clearance space with insulation or any other building materials surrounding the chimney.
INSTALLATION AND MAINTENANCE INSTRUCTIONS 1700ºF Air-Cooled Temp/Guard Chimney Sizes 8-16 Listing No. MH8251 Tested to UL103/ULC-S604 A MAJOR CAUSE OF RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCE
More informationOur non-positional lock system on the Selkirk. The Locktab is located on the female end of the gas vent.
LockTab Feature for Type Gas Vent Our non-positional lock system on the Selkirk Gas Vent is the best lock system on the market today. The incorporation of the LockTab feature simply improves our lock system
More informationTYPE "B" GAS VENT. Do not connect gas vent to a solid or liquid fuelled appliance or any appliance requiring a chimney.
TYPE "B" GAS VENT SD (sizes 3", 4", 5", 6", 7") INSTALLATION INSTRUCTIONS Type "B" Gas Vents are strictly for interior or enclosed exterior use or exterior use above a roof line. Read vent and appliance
More informationECOVENT USA CHIMNEY MODEL EV-SHT 5"-8" DIAMETER INSTALLATION INSTRUCTIONS
ECOVENT USA CHIMNEY MODEL EV-SHT 5"-8" DIAMETER INSTALLATION INSTRUCTIONS A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS
More informationContemporary Collection
HZ30E - 10 Gas Fireplace Model HZ30E-NG10 HZ30E-LP10 Fuel Type Natural Gas Propane Gas Minimum Supply Pressure Manifold Pressure - High 5 W.C. (1.5 kpa) 3.5 W.C. (0.87 kpa) 11 W.C. (.74 kpa) 10 W.C. (.49
More informationContemporary Collection
HZ5E Gas Fireplace Model HZ5E-NG1 HZ5E-LP1 Fuel Type Natural Gas Propane Gas Minimum Supply Pressure 5 W.C.(1.5 kpa) 1 W.C. (.98 kpa) Manifold Pressure - High 3.5 W.C. (.87 kpa) 1 W.C. (.9 kpa) Manifold
More informationPRODUCT CATALOGUE RIGID STAINLESS STEEL CHIMNEY LINER. 5" to 8" Diameter
PRODUT TLOGUE RIGID STINLESS STEEL HIMNEY LINER 5" to 8" Diameter Listed To: UL-S635, UL-S640 and UL 1777 Get the Selkirk dvantage... The tradition continues...selkirk is the original innovator of prefabricated
More informationVERTICAL BALANCED FLUE SYSTEM INSTALLATION INSTRUCTIONS
VERTICAL BALANCED FLUE SYSTEM INSTALLATION INSTRUCTIONS ROOM SEALED NON-CONDENSING COMBINATION/SYSTEM BOILERS AND WATER HEATERS 24i 47 311 37/38 9/14 CBi 41 311 50/51 28i 47 311 54 14/19 CBi 41 311 52/53
More informationINSUL-FLUE is used to reduce the danger of radiant heat from smoke pipe, flue pipe, gas vents, etc. igniting combustibles.
INSUL-FLUE OWNER S MANUAL (6 inch) High Heat Resistant Thimble and Insulating Sleeve for Smoke Pipe When Passing Through Any Combustible Wall September 1993, Revision A INTRODUCTION CONGRATULATIONS ON
More informationHEARTH PRODUCTS KITS AND ACCESSORIES VERTICAL TERMINATION KITS FOR SECURE FLEX VERTICAL VENTING
HEARTH PRODUCTS KITS AND ACCESSORIES 750052M Rev. C 05/2014 VERTICAL TERMINATION KITS FOR SECURE FLEX VERTICAL VENTING INSTALLATION INSTRUCTIONS FOR SECURE FLEX VERTICAL TERMINATION KITS (CATALOG NO. 56L74
More information60/100 Concentric Flue System Parts
60/00 Concentric Flue System Parts MG88(MG85 m extended option) Std Concentric Flue 60/00 (Avanta Plus). Low profile bend (Avanta Plus). Telescopic terminal. Wall plates - ( x white) MG80 Vertical Terminal
More informationType B Gas Vent GV-25 CATALOG FEATURES. Round and oval gas vent pipe and fittings for residential, commercial and industrial applications.
CTLOG Type Gas Vent GV-25 Round and oval gas vent pipe and fittings for residential, commercial and industrial applications. FETURES Snap together non-positional lock system Die formed ends Venting gas
More informationGE Monogram. Installation. Instructions. 36" Vent Hood. Model ZV750. Call anywhere in the US and Canada -
at :: rangehoods. com GE Monogram Instructions Model ZV750 GE Monogram at:: rangehoods. com is a division of CAUTION WARNING Before you begin Read these instructions completely and carefully. IMPORTANT:
More informationU1500E Gas Fireplace
Model U1500E-NG U1500E-LP Fuel Type Natural Gas Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 11 W.C. (2.73 kpa) Manifold Pressure - High 3.5 W.C. (0.87 kpa) 10 W.C. (2.48 kpa) Manifold Pressure -
More informationINSTALLATION INSTRUCTIONS for PYROCLASSIC FIRES LTD. 100mm SLOPING CEILING FLUE KIT
INSTALLATION INSTRUCTIONS for PYROCLASSIC FIRES LTD 100mm SLOPING CEILING FLUE KIT THIS FLUE KIT HAS BEEN MANUFACTURED IN ACCORDANCE WITH AS/NZS 2918:2001 AND TESTED TO APPENDIX F WARNING: TO ENSURE SAFETY
More informationContemporary Collection
HZ4STE Gas Fireplace Model HZ4STE - NG1 HZ4STE-LP1 Fuel Type Natural Gas Propane Gas Minimum Supply Pressure 5 W.C.(1.5 kpa) 1 W.C. (.98 kpa) Manifold Pressure - High 3.5 W.C. (.87 kpa) 1 W.C. (.49 kpa)
More informationDURA-PLUS (SDP) INSTALLATION AND OPERATION INSTRUCTIONS MH7399
DURA-PLUS (SDP) INSTALLATION AND OPERATION INSTRUCTIONS MH7399 A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COM- BUSTIBLE MATERIALS. IT IS OF THE UTMOST
More informationEarthcore Air-Cooled ECO-Steel Chimney is not designed for use on products that operate at continuous temperatures in excess of 1000 F.
Chimney Solutions INSTALLATION AND MAINTENANCE INSTRUCTIONS 1700ºF Air-Cooled ECO-STEEL Chimney Size 13 Listing No. MH8251 Tested to UL103 A MAJOR CAUSE OF RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED
More information650 C TEMP/GUARD CHIMNEY SIZES ºC TEMP/GUARD CHIMNEY
INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR CANADA TEMP/ GUARD 650 C TEMP/GUARD CHIMNEY SIZES 6-7 - 8 300ºC TEMP/GUARD CHIMNEY Listing No. MH 8251 Tested to UL103 HT / ULC-S629 / ULC-S604 / ULC-609 SIZES
More informationDURATECH CHIMNEY 5"-8" DIAMETER INSTALLATION INSTRUCTIONS
DURATECH 5"-8" DIAMETER INSTALLATION INSTRUCTIONS MH7399 A MAJOR CAUSE OF RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPOR- TANCE
More informationInstallation & Maintenance Instructions
Installation & Maintenance Instructions This symbol on the product means the product is listed by Underwriters Laboratories, Inc. AMERI-VENT MODEL 10 FB FACTORY-BUILT CHIMNEY These are the three ways to
More informationCATALOG. Stainless Steel Flexible Chimney Liner
CATALOG Stainless Steel Flexible Chimney Liner Flex is the most premier and high performance Stainless Steel Chimney liner available. Specifications Flex Liner Material -.006 316 Stainless Steel Regular
More informationInstallation Instructions Student 101 Fume Cupboard
Installation Instructions Student 101 Fume Cupboard Refer drawing on next page 0. If your fume cupboard is supplied with a flatpack bench frame, see step1. If your fume cupboard will be mounted on an existing
More information150 MM FREE STANDING WOOD FIRE FLUE KIT INSTALLATION INSTRUCTIONS
www.jayline.co.nz www.fisherstoves.co.nz 150 MM FREE STANDING WOOD FIRE FLUE KIT INSTALLATION INSTRUCTIONS WARNING: This flue kit has been manufactured in accordance with as/nzs 2918:2001 and tested to
More informationFLEXIBLE CHIMNEY LINER PRODUCT CATALOGUE
FLEXIBLE CHIMNEY LINER PRODUCT CATALOGUE Featuring our NEW 10-Groove Design Aluminum Kits now packaged in new Slim-Line Suitcase style Cartons. Easier to Carry Easier to Stock Easier to Ship MODEL SFCL
More informationInstallation and Maintenance Manual
Installation and Maintenance Manual IM770 Group: pplied ir Part Number: IM770 Date: pril 2003 Roof Curb for Skyline TM Outdoor ir Handlers 2013 Daikin pplied IM 770 Page 1 Table of Contents General Description...
More informationRegency Bellavista B41XT-1 Gas Fireplace
Regency ellavista 1XT-1 Gas Fireplace Specifications: Model 1XT-NG 1XT-LP Fuel Type Natural Gas Propane Gas Minimum Supply Pressure Manifold Pressure - High Manifold Pressure - Low 5 W.C. (1.5 kpa) 3.5
More informationZero Clearance Fireplace 36 ELITE-ZC INSTALLATION MANUAL. Listed Tested to: U.L. 127 and portions of U.L & 907. Part # $10.
TM Zero Clearance Listed Tested to: U.L. 127 and portions of U.L. 1482 & 907 36 ELITE-ZC INSTALLATION MANUAL 10850 117th Place N.E. Kirkland, WA 98033 Part # 93508090 4020405 $10.00 P AGE 2 TABLE OF CONTENTS
More informationSECURE-TEMP ASHT + CANADA OUR PRODUCTS LIVE UP TO OUR NAME, WARNING... 2 GENERAL INFORMATION, USA & CANADIAN APPLICATIONS.. 11
SECURE-TEMP ASHT + USA OUR PRODUCTS LIVE UP TO OUR NAME, WARNING........... 2 GENERAL INFORMATION, USA & CANADIAN APPLICATIONS...2 KEEP YOUR CHIMNEY CLEAN, SIZING CHART............. 3 GENERAL INSTALLATION
More informationHALDEMAN, INC. BRAND: RUSKIN. Fire Dampers. IBD20 Deduct 1/4 Inch. Model:
LEMN, INC. REPS v.. RN: RUSKIN Fire ampers Model: FRME: MOUNTING: FUSELINK TEMP: SLEEVE/TRNS: SLEEVE LENGT: SLEEVE GUGE: SLV MTERIL: MOUNTING NGLES: NGLE IM/G: I0 educt / Inch STYLE VERTICL EGREES SLEEVE
More informationISSUE MODIF. ORDER NO. WEEK ISSUE MODIF. ORDER NO. WEEK ISSUE MODIF. ORDER NO. WEEK 01 SME SME SME
1. Summary The still pipe used with Rosemount 5900 LPG/LNG antenna is not supplied by RTR, but is to be manufactured by the customer according to the RTR drawing D9240041-910 or D7000001-466. Additional
More informationAAE Model No. PVS-HSX High School Premier Pole Vault Standards
E Model No. PVS-HSX High School Premier Pole Vault Standards luminum thletic Equipment 1000 Enterprise rive, Royersford, P 19468 Toll Free: (800) 53-5471 Fax: (610) 85-378 www.esports.com 8 7 6 5 4 3 1
More informationEXCEL FACTORY BUILT CHIMNEY INSTALLATION AND MAINTENANCE INSTRUCTIONS
EXCEL FACTORY BUILT CHIMNEY INSTALLATION AND MAINTENANCE INSTRUCTIONS A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACE) TO COMBUSTIBLE MATERIALS. IT IS OF UPMOST
More informationB3199R - Ceiling Flange B3199RCT - Ceiling Flange Dura-Copper Coated. TOLCO Fig All Steel Ceiling Plate. 216 Eaton
ttachments 3199R - eiling Flange 3199RT - eiling Flange ura-opper oated Size Range: 3 /8"-16 & 1 /2"-13 rod Material: Malleable Iron (Stainless Steel Type 304 available) Standard 3199RT is UR-OPPER coated
More informationInspire Aledora Slate Application Guidelines
July 2014 Inspire Aledora Slate Application Guidelines Only Basic Roofing Tools Required Hand fastened or fastened with a pneumatic nail gun Utility knife or a standard circular saw Tape measure, pry bar,
More informationA. Radius elbows with a construction radius of 1.5 the duct width are preferred to square elbows.
SECTION 233100 DUCTWORK 1.0 Acoustical duct lining in any part of the duct system is prohibited. All ductwork requiring insulation shall be externally insulated (Refer to the Sheet Metal Ductwork Insulation
More informationInstallation Instructions. All-Fuel Chimney System 5 to 8 diameter. DuraTech
Installation Instructions All-Fuel Chimney System 5 to 8 diameter DuraTech A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF
More informationManual FOR YOUR SAFETY. Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance.
E33 GAS INSERT ZERO CLEARANCE KIT Owner's & Installation KIT # 340-900 Manual PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING: Improper installation, adjustment, alteration, service or maintenance
More informationInstallation Instructions for. Handrail Component System
Handrail STEP-BY-STEP Installation Instructions for Handrail Component System Rise in Inches Run in Inches 8 8.5 9 9.5 10 10.5 11 11.5 12 12.5 13 13.5 14 14.5 15 8.5 47 45 43 42 40 39 38 36 35 34 33 32
More informationULTRA-TEMP TM. INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE (Canada Only) MODEL. (5 to 8 inches dia.) FACTORY-BUILT INSULATED CHIMNEY
MODEL ULTRA-TEMP TM (5 to 8 inches dia.) FACTORY-BUILT INSULATED CHIMNEY INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE (Canada Only) A MAJOR CAUSE OF CHIMNEY-RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED
More informationTEE-STL BLK 1/2" (SCH 80) TEE-STL BLK 1/2" REGULATOR-TWO STAGE REGULATOR-TWO STAGE
RELESE TE WG 00-0-000 PIPE-STL LK /" (SH 0) ZONE ISION REOR TE FTR-ORIG 00-0-000 TUING-OPPER /" O T- 00-0-000 TEE-STL LK /" (SH 0) 00-0-000 TUING-OPPER /" O T- 00-0-000 TEE-STL LK /" 00-0-000 PIPE-STL
More informationCROSSBAR RAFTER ISOMETRIC
Super Sky Products' typical glazing system consists of glass panels or "lites" which are attached to the main framing members using extruded aluminum "retainers" or "pressure plates". These retainers are
More informationPipe Product Catalog Table of Contents
Pipe Product Catalog Table of Contents Section A: Drawing #: Page Description A1 Reinforced Concrete Pipe A3 Storm Manhole Sizing Chart (48" - 96") A3.1 Storm Manhole Sizing Chart (108" - 144") A4 48"
More informationINSTALLATION GUIDE MICROWAVE OVEN UPMC3084ST. MFL _00
INSTALLATION GUIDE MICROWAVE OVEN UPMC3084ST MFL06208710_00 www.thesignaturekitchen.com YOUR SAFETY FIRST BEFORE YOU START Proper installation is the installer's responsibility! Proper installation by
More informationWARNING: If decorative shrouds are being used with Temp/Guard Chimney, Reference the Temp/Guard Addendum L2372.
TEMP/GURD INSTLLTION ND MINTENNCE INSTRUCTIONS 2100 TEMP/GURD CHIMNEY SIZES 6-7 - 8-10 - 12 This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Listing No. MH 8251
More informationDIBD2 and DIBD23 CURTAIN TYPE DYNAMIC FIRE DAMPERS 1 1 /2 AND 3 HOUR UL555 RATED FOR USE IN DYNAMIC AND STATIC SYSTEMS
00 r. Greaves Rd. Kansas City, MO 00 (1) 1- F (1) - I and I CURTIN TYPE YNMIC FIRE MPERS 1 1 / N OUR UL RTE FOR USE IN YNMIC N STTIC SYSTEMS PPLICTION I fire dampers can be installed vertically in walls
More informationInstallation Instructions. All-Fuel Chimney System 5 to 8 diameter. DuraTech
Installation Instructions All-Fuel Chimney System 5 to 8 diameter DuraTech A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF
More informationROCKFORD PROCESS CONTROL, INC.
esigners and Manufacturers of Institutional asework Hardware ROKFOR PROESS ONTROL, IN. 2020 Seventh Street Rockford, IL 61104 Phone: 815-966-2000 Fax: 815-966-2026 sales@rockfordprocess.com www.rockfordprocess.com
More informationINSTALLATION AND MAINTENANCE INSTRUCTIONS
INSTLLTION ND MINTENNCE INSTRUCTIONS 2100 TEMP/GURD CHIMNEY SIZES 6-7 - 8-10 - 12-14 1700 TEMP/GURD CHIMNEY SIZES 16-18 TEMP/ GURD This symbol on the nameplate means this product is listed by Underwriters
More informationVarioSole SE. Installation instructions
VarioSole SE Installation instructions INTRODUTION Product Information VarioSole is a universal, easy to install system for the mounting of framed PV modules on pitched roofs with a roof pitch between
More informationYOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces Installation Manual. Ortal USA - Version: 1.3 November, 2017 SKU: KPMANCIRISLUS17B
YOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces Installation Manual Ortal USA - Version: 1.3 November, 2017 SKU: KPMANCIRISLUS17B [THIS ISTALLATION MANUAL INCLUDES ASSEMBLY INSTRUCTIONS FOR THESE
More informationInstallation Instructions. All-Fuel Chimney System. DuraPlus
Installation Instructions All-Fuel Chimney System DuraPlus A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPORTANCE
More informationSECURE-TEMP ASHT+ INSTALLATION AND OPERATING INSTRUCTIONS SUMMARY. Read these instructions and keep them for future reference
SECURE-TEMP ASHT+ SUMMARY OUR PRODUCTS LIVE UP TO OUR NAME WARNING... GENERAL INFORMATION USA & CANADIAN APPLICATIONS... Factory-built CHIMNEY ", ", ", " & 0" dia. TYPE HT INSTALLATION KEEP YOUR CHIMNEY
More informationSECTION PVC THATCH SHINGLE ROOFING SYSTEM PART 1 GENERAL 1.01 SUMMARY
SECTION 07312 PVC THATCH SHINGLE ROOFING SYSTEM PART 1 GENERAL 1.01 SUMMARY A. This Section Includes the following: 1. Endureed Dominica PVC thatch shingles. 2. Self- adhering sheet underlayment. B. Related
More informationFS 5800 EXPANSION JOINT EJ FIRE BARRIER* Installation Instructions
Thermal Structures Inc. FS 5800 EXPANSION JOINT EJ FIRE BARRIER* Installation Instructions Attached Flange & Double Barrier System FLOOR TO FLOOR (F) ROOF TO ROOF (R) FLOOR TO WALL (FW) ROOF TO WALL (RW)
More informationGeberit Duofix. Installation Manual Montageanleitung Instructions de montage Istruzioni per il montaggio
Geberit Duofix Installation Manual Montageanleitung Instructions de montage Istruzioni per il montaggio Masse Geberit Duofix Element für Wand-WC, cm, mit Sigma Unterputzspülkasten cm 9¾" (500) 4¾" (0)
More informationYOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces User s Manual
YOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces User s Manual [USA Fireplace Models [THIS ISTALLATION MANUAL INCLUDES ASSEMBLY INSTRUCTIONS FOR THESE MODELS: STAND ALONE 7565 CURVED TUNNEL DOUBLE
More informationRigid Line Components and Accessories
Rigid Line Components and ccessories Rigid Coaxial Line System Components and Installation ccessories enefits Superior engineering for excellent performance Superior materials for high durability merican
More informationNon-Submersible Industrial Pressure Transducer
Non-Submersible Industrial Pressure Transducer KPSI Transducers Series 27, 28, 30 FEATURES Custom Pressure Ranges up to 2000 (13,790 kpa) Accuracy to ±0.10% FS Analog Outputs of 4-20 ma or VDC Welded 316
More informationPart No. Thread Size B Design Load Approx. Wt./100 A in. (mm) Lbs. (kn) Lbs. (kg)
ttachments Fig. 3199R - eiling Flange Fig. 3199RT - eiling Flange ura-opper oated Size Range: 3 /8"-16 & 1 /2"-13 rod Material: Malleable Iron (Stainless Steel Type 304 available) Standard 3199RT is UR-OPPER
More informationSECTION BULLET- RESISTANT DOORS
1 SECTION 08 3950 BULLET- RESISTANT DOORS PART 1- GENERAL 1.01 SUMMARY A. This Section Includes: 1. Bullet- resistant steel door and frame systems. 2. Door hardware for bullet- resistant steel door and
More informationInstallation Guide. 203 Chesterra Drive, Dahlonega, GA Toll-Free ~ Fax ~
Congratulations and Thank You for your purchase! DryJoistEZ is an easy to install structural aluminum joist that also provides an under-deck drainage system that you install over your deck framing system
More informationPanel Installation Instructions (Revised 2/26/10) (Page 1 of 7)
Panel Installation Instructions (Revised /6/0) (Page of 7) Remove Hanger Frame Topcap by depressing tabs inside top slot of hanger frame and lifting up. Hold panel flush and in a STRIGHT LINE (80 degrees
More informationENDUREED VIVA SERIES Specifications
ENDUREED VIVA SERIES Specifications SECTION 07312 HDPE THATCH SHINGLE ROOFING SYSTEM PART 1 GENERAL 1.01 SUMMARY A. This Section Includes the following: 1. Endureed Viva Series synthetic thatch shingles.
More informationThe following manual is for the 80ZC cabinet ONLY. If you require information on the Model 80 unit that fits inside this cabinet, please download the
The following manual is for the 80ZC cabinet ONLY. If you require information on the Model 80 unit that fits inside this cabinet, please download the Model 80 manual from the Stove Manuals section of our
More informationZero Clearance Fireplace 44 ELITE-ZC INSTALLATION MANUAL. Listed Tested to: U.L. 127 and portions of U.L & 907. Part # $10.
TM Zero Clearance Listed Tested to: U.L. 127 and portions of U.L. 1482 & 907 44 ELITE-ZC INSTALLATION MANUAL 10850 117th Place N.E. Kirkland, WA 98033 Part # 93508093 4020405 $10.00 P AGE 2 TABLE OF CONTENTS
More informationLORING THE SMARTER WAY TO ROAST PROPRIETARY ITEM:
TLE, MXIMUM WEIGHTS, L (KG) ROSTER (.) JOS TUING +. (.) ZONE.. 9.. 0.. 9. WLL TO L 0F STK 9.9 MINIMUM ROSTER LERNES R9.. ELETRIL ENLOSURE OOR OPENING EXHUST VENT JOS TUING EN ISION HISTORY ESRIPTION INITIL
More informationLORING THE SMARTER WAY TO ROAST PROPRIETARY ITEM:
TLE, MXIMUM WEIGHTS, L (KG) ROSTER (9) JOS TUING + (9.) GREEN EN RT + (.) EXHUST STK VENT UTO HOPPER.9.. 9.. ZONE TRIER UTO ISHRGE OOR PPROVE J HUTTON. 0....0 9. WLL TO. 0..0 0. REOMMENE LERNE.0. REOMMENE
More informationInstallation of the JD 900 Series Flex Grain Platform Auger Trough Liner Kit
www.polyskid.com P. O. Drawer 349, Monticello, GA. 31064 Phone: 800-542-7659 Fax: 706-468-2881 E-Mail: polytech@polyskid.com Installation of the JD 900 Series Flex Grain Platform Auger Trough Liner Kit
More informationPanel Installation Instructions
EXTREMELY IMPORTANT INFORMATION PLEASE READ ENTIRE PACKET! Warranty Is Void If Panels Not Installed According to Instructions 1. WARNINGS & SPECIAL NOTES 1.1 Keep panels 24 from Heaters and shield Radiant
More informationkééç=eéäé\ =KKK`çåí~Åí=ìë=~íW çêiîáëáí=ìë=çåäáåé=
kééç=eéäé\ =KKK`çåí~Åí=ìë=~íW çêiîáëáí=ìë=çåäáåé= Attic Insulation Shield must be installed when the chimney passes from a lower living space into an upper living space. R&B #3802-07(CR) Menards 6 8 20
More informationSECTION SHEET METAL FLASHING AND TRIM
SECTION 07620 PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Formed roof drainage sheet metal fabrications. 2. Formed low-slope roof sheet metal fabrications. 1.2 SUBMITTALS A. Shop Drawings: Show
More informationFord Water Meter Couplings & Accessories
Section H 2/2001 Ford Water Meter Couplings & Accessories The Ford Meter Box Co., Inc. 775 Manchester Avenue, P.O. Box 443, Wabash, Indiana, USA 46992-0443 Telephone: 260/563-3171 FAX: 1-800-826-3487 Overseas
More informationDuraPlus. Installation Instructions. All-Fuel Chimney System. C o m p l e t e V e n t i n g S o l u t i o n s
DuraPlus Installation Instructions All-Fuel Chimney System C o m p l e t e V e n t i n g S o l u t i o n s A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO
More informationRiser Extension INSTALLATION GUIDE 40100AX35 / 40100AX18. Manual 40100X35-8
Riser Extension INSTALLATION GUIDE 40100AX35 / 40100AX18 Manual 40100X35-8 3 2 4 Access covers with bolts supplied with Interceptor 1 5 14 6 11 15 Sampling Port/Cleanout cap supplied with Interceptor 12
More informationMETL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL PIONEERING INSULATED METAL PANEL TECHNOLOGY
METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL Window assembly GUIDE PIONEERING INSULATED METAL PANEL TECHNOLOGY PIONEERING INSULATED METAL PANEL TECHNOLOGY CONTENTS DETAIL TITLE FILE NO. PAGE NO. INTRODUCTION..................................................................
More informationSIT Group FLUE SYSTEMS
SIT Group LN PRODUCT LINE FLUE SYSTEMS Index Twin Flue System 80 2 Twin Flue System 60 8 Coaxial System 10 Flue System Kit 13 TWIN FLUE SYSTEM 80 SERIES CHARACTERISTICS Extruded aluminium tubes (alloy
More informationFUEL GAS PIPING SECTION A. The provisions of SECTION 15010, MECHANICAL GENERAL REQUIREMENTS, apply to this section.
FUEL GAS PIPING SECTION 15355 PART 1 GENERAL 1.1 DESCRIPTION A. The provisions of SECTION 15010, MECHANICAL GENERAL REQUIREMENTS, apply to this section. B. This specification covers both interior and exterior
More informationHousehold Appliances. Over-the-Range Microwave. Installation Instructions. For Models: HMV9302, HMV9305, HMV9306, HMV9307
Over-the-Range Microwave Household Appliances Installation Instructions For Models: HMV9302, HMV9305, HMV9306, HMV9307 PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING IMPORTANT: Save these instructions
More informationSOUTHWEST KIVA 24 FIREPLACE Prefabricated Masonry Wood Burning Firebox and Metal Frame
SOUTHWEST KIVA 24 FIREPLACE Prefabricated Masonry Wood Burning Firebox and Metal Frame INSTALLATION INSTRUCTIONS AND OPERATIONS Firebox Model SWK24 Frame Models SWKL24-LAGUNA (Figure 1) SWKS24-SANDIA SWKH24-HOPI
More informationMICROWAVE HOOD COMBINATION INSTALLATION INSTRUCTIONS
MIROWV HOO OMINTION INSTLLTION INSTRUTIONS This product is suitable for use above electric or gas cooking products up to and including 36" (91.4 cm) wide. See Installation Requirements section for further
More informationD. Thermally Sprayed Metallic Coating (Flame Spray): STD SPEC
STANDARD SPECIFICATION SECTION 05121 MISCELLANEOUS METALWORK PART 1 - GENERAL 1.01 DESCRIPTION This section includes materials, fabrication, and installation of structural steel, connecting bolts, pipes,
More informationCOMMERCIAL KITCHEN HOOD WORKSHEET/ CHECKLIST
COMMERCIAL KITCHEN HOOD WORKSHEET/ CHECKLIST Two copies of this worksheet/checklist must accompany plans sets submitted with commercial kitchen application. The applicant is responsible for assuring the
More informationA - Railing Frame Material Specifications
A - Railing Frame Material Specifications NOTE: We strongly recommend stainless steel for exterior applications. R-1 8/1/02 B Stainless Steel Spacers (For Horizontal Railing Double Post End Post using
More informationULTRA-TEMP TM. INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE (Canada Only) MODEL. (5 to 8 inches dia.) FACTORY-BUILT INSULATED CHIMNEY
MODEL ULTRA-TEMP TM (5 to 8 inches dia.) FACTORY-BUILT INSULATED CHIMNEY INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE (Canada Only) A MAJOR CAUSE OF CHIMNEY-RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED
More informationHANDRAIL HEIGHT PER LOCAL CODE AUTORITY
WOOD END CAPS PLEASE READ PLEASE READ THESE INSTRUCTIONS THOROUGHLY PRIOR TO BEGINNING THE HRWS-6CSLBW INSTALLATION! 3 1/16" [77.7mm] THIS INSTRUCTION SHEET IS INTENDED TO PROVIDE A SPECIFIC GUIDE TO FOLLOW
More informationGeneral Information...SA1-SA4
SECTION S INDEX Product Description Page Number General Information................................................................SA1-SA4 Type FSK Thruwall & Floor Seal For Conduit, Pipe or Tubing............................
More informationThe General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in this Section.
SECTION 23 31 13 METAL HVAC DUCTS PART 1 - GENERAL 1.1 RELATED DOCUMENTS The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in
More informationInstallation and Maintenance Manual IM 770-1
Installation and Maintenance Manual IM 770-1 Group: Applied Air Systems Part Number: IM 770 Date: March 2014 Skyline Outdoor Air Handler Roof Curb Table of Contents General Description... 3 Curb-Ready
More informationInstallation Guide - Evolution Series Wood Siding
Installation Guide - Evolution Series Wood Siding The following instructions pertain to the installation of Fraser Wood Siding Evolution Series on a typical wood frame construction allowing for nail penetration
More informationInspire Slate Starter Piece Hip and Ridge. 13 1/2" Height: 13 ½" Width: 12" Squares/ Pallet. Bundles/ Square
December 2017 Classic Slate Application Guidelines Only Basic Roofing Tools Required Hand fastened or fastened with a pneumatic nail gun Utility knife or a standard circular saw Tape measure, pry bar,
More informationThomas Disc Couplings Installation and Maintenance Type 54 RDG Sizes (Page 1 of 6)
Thomas Disc ouplings Installation and Maintenance Type 54 RDG Sizes 125-925 (Page 1 of 6) ATEX In order for this coupling to meet the ATEX requirements, it is mandatory to precisely follow these installation
More informationFACTORY BUILT INSULATED CHIMNEY
& INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE (CANADA & UNITED STATES) FACTORY BUILT INSULATED CHIMNEY LISTED Tested to UL03 Type HT LISTED Tested to ULC-S604 ULC-S60 A MAJOR CAUSE OF CHIMNEY RELATED
More informationThe chimney must extend at least 2 above any part of the roof within 10 of it. A fireplace must have an intake combustion air duct installed to plan.
ROOF ASSEMBLY FURNACE VENT In the utility room or where the furnace is located, there is an access panel to inspect the furnace chimney pipe for gas fired units. Remove the cover and check to see that
More informationSERIES 4070-T GENERAL ASSEMBLY AND INSTALLATION INSTRUCTIONS
Table of Contents I. Care and Maintenance... 2 II. Tools / Materials, Sealant Requirements, & Anchor Instructions... 2 III. Structure Verification & Sub-Sillpan Installation... 3 1. Opening Verification...3
More informationINSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION & GLOSSARY ROUGH OPENINGS
Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for Vinyl windows with an integral nailing fin. While the use of these installation instructions
More informationDURATECH PREMIUM DTP
DURATECH PREMIUM DTP CONTENTS Factory-built 650 C Chimney 6, 7, & 8 dia. WARNING 2 KEEP YOUR CHIMNEY CLEAN, SIZING CHART...3 GENERAL INSTALLATION NOTES. 4-5 INTERIOR STRAIGHT INSTALLATION - SINGLE FLOOR.
More information