Our non-positional lock system on the Selkirk. The Locktab is located on the female end of the gas vent.

Size: px
Start display at page:

Download "Our non-positional lock system on the Selkirk. The Locktab is located on the female end of the gas vent."

Transcription

1 LockTab Feature for Type Gas Vent Our non-positional lock system on the Selkirk Gas Vent is the best lock system on the market today. The incorporation of the LockTab feature simply improves our lock system by adding flexibility and meeting market needs. D To use the LockTab feature: The line of Selkirk round vent pipe and fittings is designed for use on approved gas appliances in residential and light commercial and industrial applications. Round vents for large appliances will be found in the Q section which follows. Size refers to the inside diameter of the pipe or fitting. The outside diameter of is approximately 1 2" larger. Outer material is 28 G galvanized steel. Inner liner is aluminum. LOKT You no longer have to use sheet metal screws to secure pipe connections if local codes require you to. Just press the LockTab and you are done. VENT PIPE The Locktab is located on the female end of the gas vent. ssemble the gas vent sections The Locktab is then depressed with a thumb or blunt object such as a screwdriver into the lock channel of the male end To disengage the Locktab, pry it up by using a screwdriver or knifeblade Round Pipe - vailable in 6 sizes - Easy to assemble and can be combined to obtain the required installation height - Sectional overlap of 1.5". Hence, net assembled length is 1.5" less than listed lengths 3" Pipe - 5' Pipe - 4' Pipe - 3' Pipe - 2' Pipe - 18" Pipe - 12" Pipe - 6" 6" Pipe - 5' Pipe - 4' Pipe - 3' Pipe - 2' Pipe - 18" Pipe - 12" Pipe - 6" Pipe - 5' Pipe - 4' Pipe - 3' Pipe - 2' Pipe - 18" Pipe - 12" Pipe - 6" 5" Pipe - 5' Pipe - 4' Pipe - 3' Pipe - 2' Pipe - 18" Pipe - 12" Pipe - 6" 7" Pipe - 5' Pipe - 4' Pipe - 3' Pipe - 2' Pipe - 18" Pipe - 12" Pipe - 6" 8" Pipe - 5' Pipe - 4' Pipe - 3' Pipe - 2' Pipe - 18" Pipe - 12" Pipe - 6" djustable - Used in combination with a straight length, this component assures that an exact required vent length can be achieved - llows for easy disassembly and can absorb the linear expansion of longer pipe lengths - 12" adjusts from 3 1/2" to 10 1/2" - 18" adjusts from 6" to 16" 3" J12 12" J18 18" J12 12" J18 18" 5" J12 12" J18 18" 6" J12 12" J18 18" 7" J12 12" 8" J12 12" 3

2 VENT PIPE EZ djustable - Used in combination with a straight length, assures an exact length can be achieved - 12" adjusts from 3 1/2" to 10 1/2" - 18" adjusts from 6" to 16" 3" EZJ12 12" EZJ18 18" EZJ12 12" EZJ18 18" 5" EZJ12 12" EZJ18 18" 6" EZJ12 12" EZJ18 18" 7" EZJ12 12" 8" EZJ12 12" Elbows, Tees and Wyes 90 djustable Elbow - Used when an offset is required to avoid obstructions such as rafters, joists and other construction obstacles - Used to orient pipe between vertical and horizontal orientation a b - Four piece adjustable elbow twists for easy offsets 3" " " " " 5" " " 6" " " 7" " 6 1 2" 8" ",, 5", 6" 90 Elbow - Four Gore 7", 8" 90 Elbow - Three Gore 45 /60 djustable Elbow - Used when an offset is required to avoid obstructions such as rafters, joists and other construction obstacles - Three piece adjustable elbow twists for easy offsets 45 djustable Elbow Outer a b 45 /60 djustable Elbow Outer a b 7" " " 7 1 2" 8" " " 3" " 4 3 8" " " 4 3 8" " 5" " 4 3 8" " 6" " 4 3 8" " Standard Tee - Used to transition system from horizontal to vertical orientation - Provides easy access for inspection and maintenance - Tee ap sold separately a b c 3" TS 6 5 8" TS 8 1 2" 4 3 5" 5" TS 9 1 2" " 6" TS " 5 3 6" 7" TS " " 8" TS " 6 3 7" Reduction Tee vailable. Tee ap - Used at bottom of Tee - Removable for easy system maintenance 3" T T 5" T 6" T 7" T 8" T Fixed Wye 4 - Used to transition system from horizontal to vertical orientation - Provides better flue gas flow than a traditional Tee D a b c d x 3" FY 3" 10" x FY 10" 5" x 3" FY 5" 5" 3" 10" 5" x FY 5" 5" 10" 5" x x 3" FY 5" 3" 11.5" 5" x x FY 5" 11.5" 6" x 3" FY 6" 6" 3" 11" 6" x FY 6" 6" 11" 6" x 5" FY 6" 6" 5" 11"

3 Tops, Supports and Firestops Top (ird Proof*) - These tops cannot be used for wood burning applications - Helps prevent rain and debris from entering the vent - External screen prevents entry of most bird species a b 3" RT 6" RT 8" 4 1 5" RT 10" 5 1 6" RT 12" 6 1 7" RT " 8" RT 16" 8 1 2" Hi-Wind Top - Used in high wind environments - Improves flue gas flow to prevent downdrafts a b c 3" HWT 3" 8" 5 1 2" HWT 10" 6" 5" HWT 5" 12" 7" 6" HWT 6" " Support ssembly support plate cleat - Support Plate should be installed above the joist - Support Plate also serves as a firestop - Will support a maximum of 35' of gas vent Support a Plate Dim 3" GVS 3 5 8" 17" x 10" GVS 4 5 8" 17" x 10" 5" GVS 5 5 8" 17" x 12" 6" GVS 6 5 8" 17" x 12" 7" GVS 7 5 8" 17" x 1 8" GVS 8 5 8" 17" x 1 Gas Vent Support ollar & Hardware a 3" GVS 3 5 8" GVS 4 5 8" 5" GVS 5 5 8" 6" GVS 6 5 8" 7" GVS 7 5 8" Wall Thimble - Used to ensure clearance to combustibles is maintained - Wall Thimble also serves as a firestop - djusts from 4-1/8" to 7" to fit thickness of wall a b 3" WT 3 5 8" 7" WT 4 5 8" 8 1 5" WT 5 5 8" 9 1 2" 6" WT 6 5 8" " WT " 8" WT " Wall Support/and ssembly 4 - Used to support and stabilize the pipe against an outside wall - Will support up to 35 a 3" WS/ 3 5 8" WS/ 4 5 8" 5" WS/ 5 5 8" 6" WS/ 6 5 8" 7" WS/ 7 5 8" 8" WS/ 8 5 8" Wall and 1" MIN DIM - Used to stabilize the pipe against an outside wall - Must be installed just above the Tee and every 6' thereafter a 3" W 3 1 2" min W 4 1 2" min 5" W 5 1 2" min Gas Vent Firestop Spacer - Used to protect combustible materials where pipe passes through a ceiling or wall - Extended bottom flange Framing Size a & b 3" FS 5 1 2" FS 6 1 2" 5" FS 7 1 2" 6" FS 8 1 2" 7" FS 9 1 2" 8" FS " 5

4 3" THROUGH 8" Tops, Supports and Firestops Quick Grip Firestop/Support - Used to support and protect combustible materials where the pipe passes through a ceiling a 3" FSP 9" FSP 10" 5" FSP 11" 6" FSP 12" UL Model a 3" FSPU 9" FSPU 10" 5" FSPU 11" 6" FSPU 12" UL-listed model includes an attached spacer ring to ensure 1 clearance to combustibles. Pipe ollar - Provides a decorative/finished appearance - Pipe collar also acts as a firestop a b c 3" G " 2 3 8" G " 2 3 8" 5" G " 2 3 8" 6" G " 2 3 8" 7" G " 2 3 8" May be used as firestop for openings in floors, ceilings and walls. Flashings and Storm ollar djustable Roof Flashing - Used where the vent passes through a roof Flat to 6/12 a b c d 3" F 3 1 2" " " F 4 1 2" 16" " F 5 1 2" " " 6" F 6 1 2" 18" " 7" F 7 1 2" " 16" " 8" F 8 1 2" " /12 to 12/12 a b c d 3" F " 18" F " " 16" " 5" F " " " F " " " 7" F " " " 8" F " 25" " " Tall one djustable Roof Flashing - Used where the vent passes through a roof - djustable to 6/12 pitch a b c 3" TF " " TF " " 5" TF " " 6" TF " " 7" TF " 8" TF " 23" Tall one Flat Roof Flashing - Used on flat roof surfaces a b c 3" TF 12" 7 1 2" " TF 12" 7 1 2" " 5" TF 12" 7 1 2" " 6" TF 12" 11" " 7" TF 12" 11" " 8" TF 12" 11" " Storm ollar 6 - Used to provide a weather proof seal to pipe above roof line - Used above the Flashing - Seal inner edge with hi-temp silicone sealant a b 3" S " 6 5 8" S " 7 5 8" 5" S " 8 5 8" 6" S " 9 5 8" 7" S " " S " 11 3 See instructions for use/limitations

5 dapters, onnectors and Increasers Draft Hood onnector - onnects single wall Vent to Vent - Used to connect pipe to draft hood at appliance Draft Hood onnector Long 3" DH 4 1 2" DH 4 1 2" 5" DH 4 1 2" 6" DH 4 1 2" 7" DH 7" 8" DH 8" DHL 5" Universal dapters - Used to connect Vent to/from 1/ Type Gas Vent - llows Selkirk Vent to be used in conjunction with other brands of existing vent. Universal dapter - Male 3" UM UM 5" UM 6" UM 7" UM 8" UM Male adapter used to adapt to Selkirk pipe toward termination. Universal dapter - Female 3" UF UF 5" UF 6" UF 7" UF 8" UF Female adapter used to adapt to Selkirk pipe toward appliance. ppliance Increasers - Increase 3" to only Rheem/Rudd ppliance dapter 3" x I4 3" x * 4-3R * Only for use with Rheem / Rudd appliances Double Wall Increaser - Used to increase pipe diameter 3" 5" 3" x I4DW 3" x 5" I5DW x 5" I5DW x 6" I6DW 5" x 6" I6DW Low Profile Double Wall Increaser - Used to increase pipe diameter - Used for tight installations to optimize space 1" 3" 3" x I4 3" x 5" I5 3" x 6" I6 3" x 7" I7 3" x 8" I8 x 5" I5 x 6" I6 x 7" I7 x 8" I8 5" 5" x 6" I6 6" x 7" I7 5" x 7" I7 7" 6" x 8" I8 5" x 8" I8 7" x 8" I8 8" 8" x 10" I10 Other sizes available for project work on special order. llow 30 working days after placing order. Maximum screw size 3 8" 6" Reducer 3 One step only 1 Step R3 x 3" 5" R4 5" x 6" R5 6" x 5" 7" R6 7" x 6" 8" R7 8" x 7" 7

Type B Gas Vent GV-25 CATALOG FEATURES. Round and oval gas vent pipe and fittings for residential, commercial and industrial applications.

Type B Gas Vent GV-25 CATALOG FEATURES. Round and oval gas vent pipe and fittings for residential, commercial and industrial applications. CTLOG Type Gas Vent GV-25 Round and oval gas vent pipe and fittings for residential, commercial and industrial applications. FETURES Snap together non-positional lock system Die formed ends Venting gas

More information

TYPE "B" GAS VENT. Do not connect gas vent to a solid or liquid fuelled appliance or any appliance requiring a chimney.

TYPE B GAS VENT. Do not connect gas vent to a solid or liquid fuelled appliance or any appliance requiring a chimney. TYPE "B" GAS VENT SD (sizes 3", 4", 5", 6", 7") INSTALLATION INSTRUCTIONS Type "B" Gas Vents are strictly for interior or enclosed exterior use or exterior use above a roof line. Read vent and appliance

More information

Contemporary Collection

Contemporary Collection HZ30E - 10 Gas Fireplace Model HZ30E-NG10 HZ30E-LP10 Fuel Type Natural Gas Propane Gas Minimum Supply Pressure Manifold Pressure - High 5 W.C. (1.5 kpa) 3.5 W.C. (0.87 kpa) 11 W.C. (.74 kpa) 10 W.C. (.49

More information

ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JEROME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) FAX: (450)

ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JEROME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) FAX: (450) ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JEROME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) 565-6336 FAX: (450)565-6519 www.icc-rsf.com INSTALLATION AND OPERATION INSTRUCTIONS "Model VIP" CHIMNEY TYPE: FACTORY BUILT

More information

ECOVENT USA CHIMNEY MODEL EV-SHT 5"-8" DIAMETER INSTALLATION INSTRUCTIONS

ECOVENT USA CHIMNEY MODEL EV-SHT 5-8 DIAMETER INSTALLATION INSTRUCTIONS ECOVENT USA CHIMNEY MODEL EV-SHT 5"-8" DIAMETER INSTALLATION INSTRUCTIONS A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS

More information

Contemporary Collection

Contemporary Collection HZ5E Gas Fireplace Model HZ5E-NG1 HZ5E-LP1 Fuel Type Natural Gas Propane Gas Minimum Supply Pressure 5 W.C.(1.5 kpa) 1 W.C. (.98 kpa) Manifold Pressure - High 3.5 W.C. (.87 kpa) 1 W.C. (.9 kpa) Manifold

More information

VERTICAL BALANCED FLUE SYSTEM INSTALLATION INSTRUCTIONS

VERTICAL BALANCED FLUE SYSTEM INSTALLATION INSTRUCTIONS VERTICAL BALANCED FLUE SYSTEM INSTALLATION INSTRUCTIONS ROOM SEALED NON-CONDENSING COMBINATION/SYSTEM BOILERS AND WATER HEATERS 24i 47 311 37/38 9/14 CBi 41 311 50/51 28i 47 311 54 14/19 CBi 41 311 52/53

More information

Never fill any required clearance space with insulation or any other building materials surrounding the chimney.

Never fill any required clearance space with insulation or any other building materials surrounding the chimney. INSTALLATION AND MAINTENANCE INSTRUCTIONS 1700ºF Air-Cooled Temp/Guard Chimney Sizes 8-16 Listing No. MH8251 Tested to UL103/ULC-S604 A MAJOR CAUSE OF RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCE

More information

DURA-PLUS (SDP) INSTALLATION AND OPERATION INSTRUCTIONS MH7399

DURA-PLUS (SDP) INSTALLATION AND OPERATION INSTRUCTIONS MH7399 DURA-PLUS (SDP) INSTALLATION AND OPERATION INSTRUCTIONS MH7399 A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COM- BUSTIBLE MATERIALS. IT IS OF THE UTMOST

More information

ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JÉRÔME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) FAX: (450) INSTALLATION AND OPERATION INSTRUCTIONS

ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JÉRÔME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) FAX: (450) INSTALLATION AND OPERATION INSTRUCTIONS ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JÉRÔME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) 565-6336 FAX: (450)565-6519 INSTALLATION AND OPERATION INSTRUCTIONS "IS" CHIMNEY TYPE: SIZE: FACTORY BUILT CHIMNEY FOR

More information

PRODUCT CATALOGUE RIGID STAINLESS STEEL CHIMNEY LINER. 5" to 8" Diameter

PRODUCT CATALOGUE RIGID STAINLESS STEEL CHIMNEY LINER. 5 to 8 Diameter PRODUT TLOGUE RIGID STINLESS STEEL HIMNEY LINER 5" to 8" Diameter Listed To: UL-S635, UL-S640 and UL 1777 Get the Selkirk dvantage... The tradition continues...selkirk is the original innovator of prefabricated

More information

HEARTH PRODUCTS KITS AND ACCESSORIES VERTICAL TERMINATION KITS FOR SECURE FLEX VERTICAL VENTING

HEARTH PRODUCTS KITS AND ACCESSORIES VERTICAL TERMINATION KITS FOR SECURE FLEX VERTICAL VENTING HEARTH PRODUCTS KITS AND ACCESSORIES 750052M Rev. C 05/2014 VERTICAL TERMINATION KITS FOR SECURE FLEX VERTICAL VENTING INSTALLATION INSTRUCTIONS FOR SECURE FLEX VERTICAL TERMINATION KITS (CATALOG NO. 56L74

More information

RESIDENTIAL TYPE B GAS VENT

RESIDENTIAL TYPE B GAS VENT TLOGUE SEPTEMER 1998 RESIENTIL TYPE GS VENT TYPE GS VENT SIZING INFORMTION In anada, to calculate -Vent sizing, refer to Gas Sizing harts located in the Natural Gas Installation ode N/G 149.1 and/or the

More information

Contemporary Collection

Contemporary Collection HZ4STE Gas Fireplace Model HZ4STE - NG1 HZ4STE-LP1 Fuel Type Natural Gas Propane Gas Minimum Supply Pressure 5 W.C.(1.5 kpa) 1 W.C. (.98 kpa) Manifold Pressure - High 3.5 W.C. (.87 kpa) 1 W.C. (.49 kpa)

More information

DURATECH CHIMNEY 5"-8" DIAMETER INSTALLATION INSTRUCTIONS

DURATECH CHIMNEY 5-8 DIAMETER INSTALLATION INSTRUCTIONS DURATECH 5"-8" DIAMETER INSTALLATION INSTRUCTIONS MH7399 A MAJOR CAUSE OF RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPOR- TANCE

More information

INSUL-FLUE is used to reduce the danger of radiant heat from smoke pipe, flue pipe, gas vents, etc. igniting combustibles.

INSUL-FLUE is used to reduce the danger of radiant heat from smoke pipe, flue pipe, gas vents, etc. igniting combustibles. INSUL-FLUE OWNER S MANUAL (6 inch) High Heat Resistant Thimble and Insulating Sleeve for Smoke Pipe When Passing Through Any Combustible Wall September 1993, Revision A INTRODUCTION CONGRATULATIONS ON

More information

Regency Bellavista B41XT-1 Gas Fireplace

Regency Bellavista B41XT-1 Gas Fireplace Regency ellavista 1XT-1 Gas Fireplace Specifications: Model 1XT-NG 1XT-LP Fuel Type Natural Gas Propane Gas Minimum Supply Pressure Manifold Pressure - High Manifold Pressure - Low 5 W.C. (1.5 kpa) 3.5

More information

U1500E Gas Fireplace

U1500E Gas Fireplace Model U1500E-NG U1500E-LP Fuel Type Natural Gas Propane Minimum Supply Pressure 5 W.C. (1.25 kpa) 11 W.C. (2.73 kpa) Manifold Pressure - High 3.5 W.C. (0.87 kpa) 10 W.C. (2.48 kpa) Manifold Pressure -

More information

Installation & Maintenance Instructions

Installation & Maintenance Instructions Installation & Maintenance Instructions This symbol on the product means the product is listed by Underwriters Laboratories, Inc. AMERI-VENT MODEL 10 FB FACTORY-BUILT CHIMNEY These are the three ways to

More information

ULTRA-TEMP TM. INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE (Canada Only) MODEL. (5 to 8 inches dia.) FACTORY-BUILT INSULATED CHIMNEY

ULTRA-TEMP TM. INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE (Canada Only) MODEL. (5 to 8 inches dia.) FACTORY-BUILT INSULATED CHIMNEY MODEL ULTRA-TEMP TM (5 to 8 inches dia.) FACTORY-BUILT INSULATED CHIMNEY INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE (Canada Only) A MAJOR CAUSE OF CHIMNEY-RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED

More information

Installation Instructions. All-Fuel Chimney System 5 to 8 diameter. DuraTech

Installation Instructions. All-Fuel Chimney System 5 to 8 diameter. DuraTech Installation Instructions All-Fuel Chimney System 5 to 8 diameter DuraTech A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF

More information

Zero Clearance Fireplace 36 ELITE-ZC INSTALLATION MANUAL. Listed Tested to: U.L. 127 and portions of U.L & 907. Part # $10.

Zero Clearance Fireplace 36 ELITE-ZC INSTALLATION MANUAL. Listed Tested to: U.L. 127 and portions of U.L & 907. Part # $10. TM Zero Clearance Listed Tested to: U.L. 127 and portions of U.L. 1482 & 907 36 ELITE-ZC INSTALLATION MANUAL 10850 117th Place N.E. Kirkland, WA 98033 Part # 93508090 4020405 $10.00 P AGE 2 TABLE OF CONTENTS

More information

Linear Motion and Assembly Technologies Aluminum Framing /07. Die-Cast Foundation Brackets 3-10 & 3-11

Linear Motion and Assembly Technologies Aluminum Framing /07. Die-Cast Foundation Brackets 3-10 & 3-11 -0 Linear Motion and ssembly Technologies luminum Framing 91 500 1 /07 Section : Profile onnectors Overview One of the greatest strengths of the osch Rexroth structural aluminum framing system is the wide

More information

Installation Instructions. All-Fuel Chimney System 5 to 8 diameter. DuraTech

Installation Instructions. All-Fuel Chimney System 5 to 8 diameter. DuraTech Installation Instructions All-Fuel Chimney System 5 to 8 diameter DuraTech A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF

More information

DuraPlus. Installation Instructions. All-Fuel Chimney System. C o m p l e t e V e n t i n g S o l u t i o n s

DuraPlus. Installation Instructions. All-Fuel Chimney System. C o m p l e t e V e n t i n g S o l u t i o n s DuraPlus Installation Instructions All-Fuel Chimney System C o m p l e t e V e n t i n g S o l u t i o n s A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO

More information

Installation Instructions. All-Fuel Chimney System 10 to 24 diameter. DuraTech

Installation Instructions. All-Fuel Chimney System 10 to 24 diameter. DuraTech Installation Instructions All-Fuel Chimney System 10 to 24 diameter DuraTech A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS

More information

SECURE-TEMP ASHT + CANADA OUR PRODUCTS LIVE UP TO OUR NAME, WARNING... 2 GENERAL INFORMATION, USA & CANADIAN APPLICATIONS.. 11

SECURE-TEMP ASHT + CANADA OUR PRODUCTS LIVE UP TO OUR NAME, WARNING... 2 GENERAL INFORMATION, USA & CANADIAN APPLICATIONS.. 11 SECURE-TEMP ASHT + USA OUR PRODUCTS LIVE UP TO OUR NAME, WARNING........... 2 GENERAL INFORMATION, USA & CANADIAN APPLICATIONS...2 KEEP YOUR CHIMNEY CLEAN, SIZING CHART............. 3 GENERAL INSTALLATION

More information

Earthcore Air-Cooled ECO-Steel Chimney is not designed for use on products that operate at continuous temperatures in excess of 1000 F.

Earthcore Air-Cooled ECO-Steel Chimney is not designed for use on products that operate at continuous temperatures in excess of 1000 F. Chimney Solutions INSTALLATION AND MAINTENANCE INSTRUCTIONS 1700ºF Air-Cooled ECO-STEEL Chimney Size 13 Listing No. MH8251 Tested to UL103 A MAJOR CAUSE OF RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED

More information

Manual FOR YOUR SAFETY. Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance.

Manual FOR YOUR SAFETY. Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance. E33 GAS INSERT ZERO CLEARANCE KIT Owner's & Installation KIT # 340-900 Manual PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING: Improper installation, adjustment, alteration, service or maintenance

More information

Installation Instructions. All-Fuel Chimney System. DuraPlus

Installation Instructions. All-Fuel Chimney System. DuraPlus Installation Instructions All-Fuel Chimney System DuraPlus A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPORTANCE

More information

150 MM FREE STANDING WOOD FIRE FLUE KIT INSTALLATION INSTRUCTIONS

150 MM FREE STANDING WOOD FIRE FLUE KIT INSTALLATION INSTRUCTIONS www.jayline.co.nz www.fisherstoves.co.nz 150 MM FREE STANDING WOOD FIRE FLUE KIT INSTALLATION INSTRUCTIONS WARNING: This flue kit has been manufactured in accordance with as/nzs 2918:2001 and tested to

More information

Kiva Fireplace WOOD BURNING INSTALLATION MANUAL

Kiva Fireplace WOOD BURNING INSTALLATION MANUAL 18 24 30 Kiva Fireplace WOOD BURNING INSTALLATION MANUAL Frame Models: Orno Santa Fe Navajo Zuni Keep these instructions for future use. C This fireplace is to be installed ONLY by a construction industry

More information

INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE

INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE (125mm to 200mm dia.) INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE United Kingdom FACTORY- BUILT INSULATED CHIMNEY Tested for compliance with BS EN1856-1:2003 Product Designation T450 - N1 - D - Vm-L50045

More information

Zero Clearance Fireplace 44 ELITE-ZC INSTALLATION MANUAL. Listed Tested to: U.L. 127 and portions of U.L & 907. Part # $10.

Zero Clearance Fireplace 44 ELITE-ZC INSTALLATION MANUAL. Listed Tested to: U.L. 127 and portions of U.L & 907. Part # $10. TM Zero Clearance Listed Tested to: U.L. 127 and portions of U.L. 1482 & 907 44 ELITE-ZC INSTALLATION MANUAL 10850 117th Place N.E. Kirkland, WA 98033 Part # 93508093 4020405 $10.00 P AGE 2 TABLE OF CONTENTS

More information

650 C TEMP/GUARD CHIMNEY SIZES ºC TEMP/GUARD CHIMNEY

650 C TEMP/GUARD CHIMNEY SIZES ºC TEMP/GUARD CHIMNEY INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR CANADA TEMP/ GUARD 650 C TEMP/GUARD CHIMNEY SIZES 6-7 - 8 300ºC TEMP/GUARD CHIMNEY Listing No. MH 8251 Tested to UL103 HT / ULC-S629 / ULC-S604 / ULC-609 SIZES

More information

ULTRA-TEMP TM. INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE (Canada Only) MODEL. (5 to 8 inches dia.) FACTORY-BUILT INSULATED CHIMNEY

ULTRA-TEMP TM. INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE (Canada Only) MODEL. (5 to 8 inches dia.) FACTORY-BUILT INSULATED CHIMNEY MODEL ULTRA-TEMP TM (5 to 8 inches dia.) FACTORY-BUILT INSULATED CHIMNEY INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE (Canada Only) A MAJOR CAUSE OF CHIMNEY-RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED

More information

GE Monogram. Installation. Instructions. 36" Vent Hood. Model ZV750. Call anywhere in the US and Canada -

GE Monogram. Installation. Instructions. 36 Vent Hood. Model ZV750. Call anywhere in the US and Canada - at :: rangehoods. com GE Monogram Instructions Model ZV750 GE Monogram at:: rangehoods. com is a division of CAUTION WARNING Before you begin Read these instructions completely and carefully. IMPORTANT:

More information

SOUTHWEST KIVA 24 FIREPLACE Prefabricated Masonry Wood Burning Firebox and Metal Frame

SOUTHWEST KIVA 24 FIREPLACE Prefabricated Masonry Wood Burning Firebox and Metal Frame SOUTHWEST KIVA 24 FIREPLACE Prefabricated Masonry Wood Burning Firebox and Metal Frame INSTALLATION INSTRUCTIONS AND OPERATIONS Firebox Model SWK24 Frame Models SWKL24-LAGUNA (Figure 1) SWKS24-SANDIA SWKH24-HOPI

More information

CROSSBAR RAFTER ISOMETRIC

CROSSBAR RAFTER ISOMETRIC Super Sky Products' typical glazing system consists of glass panels or "lites" which are attached to the main framing members using extruded aluminum "retainers" or "pressure plates". These retainers are

More information

FACTORY BUILT INSULATED CHIMNEY

FACTORY BUILT INSULATED CHIMNEY & INSTALLATION INSTRUCTIONS & MAINTENANCE GUIDE (CANADA & UNITED STATES) FACTORY BUILT INSULATED CHIMNEY LISTED Tested to UL03 Type HT LISTED Tested to ULC-S604 ULC-S60 A MAJOR CAUSE OF CHIMNEY RELATED

More information

CATALOG. Stainless Steel Flexible Chimney Liner

CATALOG. Stainless Steel Flexible Chimney Liner CATALOG Stainless Steel Flexible Chimney Liner Flex is the most premier and high performance Stainless Steel Chimney liner available. Specifications Flex Liner Material -.006 316 Stainless Steel Regular

More information

kééç=eéäé\ =KKK`çåí~Åí=ìë=~íW çêiîáëáí=ìë=çåäáåé=

kééç=eéäé\ =KKK`çåí~Åí=ìë=~íW çêiîáëáí=ìë=çåäáåé= kééç=eéäé\ =KKK`çåí~Åí=ìë=~íW çêiîáëáí=ìë=çåäáåé= Attic Insulation Shield must be installed when the chimney passes from a lower living space into an upper living space. R&B #3802-07(CR) Menards 6 8 20

More information

EXCEL FACTORY BUILT CHIMNEY INSTALLATION AND MAINTENANCE INSTRUCTIONS

EXCEL FACTORY BUILT CHIMNEY INSTALLATION AND MAINTENANCE INSTRUCTIONS EXCEL FACTORY BUILT CHIMNEY INSTALLATION AND MAINTENANCE INSTRUCTIONS A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACE) TO COMBUSTIBLE MATERIALS. IT IS OF UPMOST

More information

60/100 Concentric Flue System Parts

60/100 Concentric Flue System Parts 60/00 Concentric Flue System Parts MG88(MG85 m extended option) Std Concentric Flue 60/00 (Avanta Plus). Low profile bend (Avanta Plus). Telescopic terminal. Wall plates - ( x white) MG80 Vertical Terminal

More information

FLEXIBLE CHIMNEY LINER PRODUCT CATALOGUE

FLEXIBLE CHIMNEY LINER PRODUCT CATALOGUE FLEXIBLE CHIMNEY LINER PRODUCT CATALOGUE Featuring our NEW 10-Groove Design Aluminum Kits now packaged in new Slim-Line Suitcase style Cartons. Easier to Carry Easier to Stock Easier to Ship MODEL SFCL

More information

Rheem Room Sealed Kit - Installation Instructions. Installation must be carried out by a licenced plumber

Rheem Room Sealed Kit - Installation Instructions. Installation must be carried out by a licenced plumber Rheem 631275 Room Sealed Kit - Installation Instructions Installation must be carried out by a licenced plumber General The Rheem Room Sealed Balanced Flue Kit is designed to connect to a 631275 heavy

More information

The following manual is for the 80ZC cabinet ONLY. If you require information on the Model 80 unit that fits inside this cabinet, please download the

The following manual is for the 80ZC cabinet ONLY. If you require information on the Model 80 unit that fits inside this cabinet, please download the The following manual is for the 80ZC cabinet ONLY. If you require information on the Model 80 unit that fits inside this cabinet, please download the Model 80 manual from the Stove Manuals section of our

More information

C Series. Cool Surface System INSTRUCTION MANUAL FRONT VENT [ ] PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE

C Series. Cool Surface System INSTRUCTION MANUAL FRONT VENT [ ] PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE C Series Cool Surface System FRONT VENT [50-3463] INSTRUCTION MANUAL 4001609 This Cool Surface System has been tested for compliance to Standards: ANSI

More information

KS SERIES - VERTICAL INSTALLATION

KS SERIES - VERTICAL INSTALLATION CS-DS-01-KSV CS DISCLAIMER CS-PJ-01-KSV KS42SL EXPANDED PANEL JOINT CS-PJ-02-KSV KS42SL ENGAGED PANEL JOINT CS-PJ-03-KSV KS45SL EXPANDED PANEL JOINT CS-PJ-04-KSV KS45 FLAT ENGAGED PANEL JOINT CS-PJ-05-KSV

More information

INSTALLATION INSTRUCTIONS for PYROCLASSIC FIRES LTD. 100mm SLOPING CEILING FLUE KIT

INSTALLATION INSTRUCTIONS for PYROCLASSIC FIRES LTD. 100mm SLOPING CEILING FLUE KIT INSTALLATION INSTRUCTIONS for PYROCLASSIC FIRES LTD 100mm SLOPING CEILING FLUE KIT THIS FLUE KIT HAS BEEN MANUFACTURED IN ACCORDANCE WITH AS/NZS 2918:2001 AND TESTED TO APPENDIX F WARNING: TO ENSURE SAFETY

More information

Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions

Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions PO Box 480 Ph: 417-235-7821 Monett, MO 65708 Fax: 417-737-7140 Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions These installation instructions are recommendations

More information

SECURE-TEMP ASHT+ INSTALLATION AND OPERATING INSTRUCTIONS SUMMARY. Read these instructions and keep them for future reference

SECURE-TEMP ASHT+ INSTALLATION AND OPERATING INSTRUCTIONS SUMMARY. Read these instructions and keep them for future reference SECURE-TEMP ASHT+ SUMMARY OUR PRODUCTS LIVE UP TO OUR NAME WARNING... GENERAL INFORMATION USA & CANADIAN APPLICATIONS... Factory-built CHIMNEY ", ", ", " & 0" dia. TYPE HT INSTALLATION KEEP YOUR CHIMNEY

More information

PLEASE READ AND UNDERSTAND THE REQUIREMENTS BEFORE PROCEEDING

PLEASE READ AND UNDERSTAND THE REQUIREMENTS BEFORE PROCEEDING Model TLC All-Fuel Chimney - 5" to 8" Factory-Built Type HT Insulated Chimney - Tested to UL103 PLEASE READ AND UNDERSTAND THE REQUIREMENTS BEFORE PROCEEDING Type of Appliances Your Model TLC chimney is

More information

FS 5800 EXPANSION JOINT EJ FIRE BARRIER* Installation Instructions

FS 5800 EXPANSION JOINT EJ FIRE BARRIER* Installation Instructions Thermal Structures Inc. FS 5800 EXPANSION JOINT EJ FIRE BARRIER* Installation Instructions Attached Flange & Double Barrier System FLOOR TO FLOOR (F) ROOF TO ROOF (R) FLOOR TO WALL (FW) ROOF TO WALL (RW)

More information

Rigid and Flex Tubular Skylights Installation Instructions

Rigid and Flex Tubular Skylights Installation Instructions Rigid and Flex Tubular Skylights Installation Instructions S ST o not return to the store! For assistance with your Tubular Skylight installation, or for additional product information, call our toll-free

More information

IMPORTANT! READ BEFORE PROCEEDING! SV Weather Caps

IMPORTANT! READ BEFORE PROCEEDING! SV Weather Caps SV Weather Caps OPERATION & MAINTENANCE Revised: 08/24/15 IMPORTANT! READ BEFORE PROCEEDING! The information contained herein is, to the best of our knowledge, accurate and applicable for proper operation

More information

Inspire Aledora Slate Application Guidelines

Inspire Aledora Slate Application Guidelines July 2014 Inspire Aledora Slate Application Guidelines Only Basic Roofing Tools Required Hand fastened or fastened with a pneumatic nail gun Utility knife or a standard circular saw Tape measure, pry bar,

More information

Installation Instructions

Installation Instructions edium + Heavy duty READ BEFORE INSTALLING UNIT Preliminary instructions: 1. Check window opening size: the mounting parts furnished with this air conditioner are made to install in a wooden sill double-hung

More information

READ BEFORE INSTALLING UNIT INSTALLATION WARNINGS AND CAUTION

READ BEFORE INSTALLING UNIT INSTALLATION WARNINGS AND CAUTION edium + Heavy duty READ BEFORE INSTALLING UNIT INSTALLATION WARNINGS AND CAUTION Carefully read the installation manual before beginning. Pay attention to danger and safety notices. be exposed: Carefully

More information

Inspire Slate Starter Piece Hip and Ridge. 13 1/2" Height: 13 ½" Width: 12" Squares/ Pallet. Bundles/ Square

Inspire Slate Starter Piece Hip and Ridge. 13 1/2 Height: 13 ½ Width: 12 Squares/ Pallet. Bundles/ Square December 2017 Classic Slate Application Guidelines Only Basic Roofing Tools Required Hand fastened or fastened with a pneumatic nail gun Utility knife or a standard circular saw Tape measure, pry bar,

More information

Dura-Lock Roof System

Dura-Lock Roof System DLR-14 Dura-Lock Roof System Assembly and Installation Instructions Read the instructions before starting the job. They explain the steps required to produce a finished product that will meet factory specifications.

More information

A. Radius elbows with a construction radius of 1.5 the duct width are preferred to square elbows.

A. Radius elbows with a construction radius of 1.5 the duct width are preferred to square elbows. SECTION 233100 DUCTWORK 1.0 Acoustical duct lining in any part of the duct system is prohibited. All ductwork requiring insulation shall be externally insulated (Refer to the Sheet Metal Ductwork Insulation

More information

YOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces Installation Manual. Ortal USA - Version: 1.3 November, 2017 SKU: KPMANCIRISLUS17B

YOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces Installation Manual. Ortal USA - Version: 1.3 November, 2017 SKU: KPMANCIRISLUS17B YOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces Installation Manual Ortal USA - Version: 1.3 November, 2017 SKU: KPMANCIRISLUS17B [THIS ISTALLATION MANUAL INCLUDES ASSEMBLY INSTRUCTIONS FOR THESE

More information

SILVERBACK INSTALLATION MANUAL

SILVERBACK INSTALLATION MANUAL SILVERBACK INSTALLATION MANUAL R-SERIES SOLAR RACKS T OLL FREE 866-766-3727 WWW.ROOFSCREEN.COM Introduction... 2 The Silverback Solar Racking System... 2 This manual... 2 Application... 2 System Overview...

More information

Flush Round Single or Multi-Service Non-Metallic Concrete Floor Box Floor Boxes

Flush Round Single or Multi-Service Non-Metallic Concrete Floor Box Floor Boxes Flush Round Single or Multi-Service Non-Metallic Concrete Floor ox Flush Round Single or Multi-Service Non-Metallic Concrete Floor ox Dimensions Inches (mm) D C PF1 Min. Depth of Pour 3.00" (76.2) Capacity

More information

3 Emergency Breakaway Coupling

3 Emergency Breakaway Coupling SM64227 July 2008 Applicable addition manuals: N/A Aerospace Group Conveyance Systems Division Carter Ground Fueling Maintenance & Repair Manual 3 Emergency Breakaway Coupling Model 64227 Table of Contents

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS PEDESTAL WOOD STOVE FRESH AIR ADAPTER KIT AC01336 INSTALLATION INSTRUCTIONS Stove Builder International inc. 250, rue de Copenhague Saint-Augustin-de-Desmaures Quebec, Canada G3A 2H3 45619A Printed in

More information

for Rigid Sun Lite Planning the layout

for Rigid Sun Lite Planning the layout for Rigid Sun Lite These instructions refer to installations on a flat and pitched roof. Various roof flashing units are available according to the particular roof covering. The roof flashing will be boxed

More information

Installation Instructions

Installation Instructions For Medium (15-18.5K) + Heavy duty (22-28.5K) Air Conditioner READ BEFORE INSTALLING UNIT To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp

More information

Island Wood Range Hood

Island Wood Range Hood Island Wood Range Hood Patent Pending Important Notes Always read the instructions completely and carefully before beginning assembly. Remove and check contents for damage and/or missing parts. Keep the

More information

Installation Guide. Model #400. Corporate Office: 349 Highland Road East Macedonia, Ohio

Installation Guide. Model #400. Corporate Office: 349 Highland Road East Macedonia, Ohio Installation Guide Model #400 Corporate Office: 349 Highland Road East Macedonia, Ohio 44056 1.866.822.7328 www.ezbreathe.com Copyright 2006, EZ Breathe, LLC WHAT S INSIDE Before installing your EZ Breathe

More information

YOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces User s Manual

YOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces User s Manual YOUR LIFE. YOUR FIRE. Ortal Curved & Islands Fireplaces User s Manual [USA Fireplace Models [THIS ISTALLATION MANUAL INCLUDES ASSEMBLY INSTRUCTIONS FOR THESE MODELS: STAND ALONE 7565 CURVED TUNNEL DOUBLE

More information

INSTALLATION INSTRUCTIONS TRI-ROOF. energy for a better world

INSTALLATION INSTRUCTIONS TRI-ROOF. energy for a better world energy for a better world INSTALLATION INSTRUCTIONS TRI-ROOF The flexible roof integration system Compatible for framed module types* Simple exchange of modules Replaces existing roofing Special profiles

More information

DURATECH PREMIUM DTP

DURATECH PREMIUM DTP DURATECH PREMIUM DTP CONTENTS Factory-built 650 C Chimney 6, 7, & 8 dia. WARNING 2 KEEP YOUR CHIMNEY CLEAN, SIZING CHART...3 GENERAL INSTALLATION NOTES. 4-5 INTERIOR STRAIGHT INSTALLATION - SINGLE FLOOR.

More information

SuperFOIL Insulation. Solutions Guide. Pitched Roof - Under Rafter

SuperFOIL Insulation. Solutions Guide. Pitched Roof - Under Rafter SuperFOIL Insulation Solutions Guide Pitched Roof - Under Rafter SF19+ Pitched Roof Under Rafter Solutions CONSTRUCTION THICKNESS R -VALUE EXTERNAL SURFACE - 0.040 TILES / SLATES 10mm - BATTEN CAVITY 25mm

More information

Roof Attachment Overview

Roof Attachment Overview Roof Attachment Overview MY STORY Brandon Gwinner Account Executive OUR RACKING SOLUTIONS - Construction and Sales for over 15 years - SunModo brand representative for over 5 years - OSEIA board of Directors

More information

Pipe Product Catalog Table of Contents

Pipe Product Catalog Table of Contents Pipe Product Catalog Table of Contents Section A: Drawing #: Page Description A1 Reinforced Concrete Pipe A3 Storm Manhole Sizing Chart (48" - 96") A3.1 Storm Manhole Sizing Chart (108" - 144") A4 48"

More information

Vinyl Windows Manufactured by VPI Quality Windows

Vinyl Windows Manufactured by VPI Quality Windows Vinyl Windows Manufactured by VPI Quality Windows Part Number: 531&591 Installation 531 & 591 SERIES SLIDING AND HUNG WINDOW INSTALLATION INSTRUCTIONS Installation Instructions for Typical Construction.

More information

TARGA 7300 CASEMENT INSTALLATION INSTRUCTIONS NOTE: Read instructions completely before attempting any installation.

TARGA 7300 CASEMENT INSTALLATION INSTRUCTIONS NOTE: Read instructions completely before attempting any installation. TARGA 7300 CASEMENT INSTALLATION INSTRUCTIONS NOTE: Read instructions completely before attempting any installation. These instructions are provided as a general guide in the installation of CGI windows.

More information

REGAL. Installation Manual

REGAL. Installation Manual REGAL Installation Manual General Information The details shown on the following pages are suggestions or guidelines for installing the Regal system. The installation details shown here are proven methods

More information

Vertical Offset Base and Safety Rail System Installation Instructions

Vertical Offset Base and Safety Rail System Installation Instructions Section 5 Vertical Offset Base and Safety Rail System Installation Instructions The vertical offset base and safety rail assembly are designed to be used in residential construction for sloped or flat

More information

Riser Extension INSTALLATION GUIDE 40100AX35 / 40100AX18. Manual 40100X35-8

Riser Extension INSTALLATION GUIDE 40100AX35 / 40100AX18. Manual 40100X35-8 Riser Extension INSTALLATION GUIDE 40100AX35 / 40100AX18 Manual 40100X35-8 3 2 4 Access covers with bolts supplied with Interceptor 1 5 14 6 11 15 Sampling Port/Cleanout cap supplied with Interceptor 12

More information

WOOD FIRE FLUE KIT AND ACCESSORIES MANUAL

WOOD FIRE FLUE KIT AND ACCESSORIES MANUAL WOOD FIRE FLUE KIT AND ACCESSORIES MANUAL Masport Limited 1-37 Mt Wellington Highway Panmure Auckland 6 Ph: 09 571 1200 Fax: 09 571 5864 www.masport.com 2005 CONTENTS Ordering Information... Page 3 Freestanding

More information

SERIES 4070-T GENERAL ASSEMBLY AND INSTALLATION INSTRUCTIONS

SERIES 4070-T GENERAL ASSEMBLY AND INSTALLATION INSTRUCTIONS Table of Contents I. Care and Maintenance... 2 II. Tools / Materials, Sealant Requirements, & Anchor Instructions... 2 III. Structure Verification & Sub-Sillpan Installation... 3 1. Opening Verification...3

More information

INSTALLATION MANUAL WEEKENDER STEEL LADDER RACK

INSTALLATION MANUAL WEEKENDER STEEL LADDER RACK TRUCK STORAGE SOLUTIONS SECURING YOUR REPUTATION INSTALLATION MANUAL WEEKENDER STEEL LADDER RACK STEEL & ALUMINUM SIDE BOX WITH PACK RAT DRAWER UNITS MODELS ATTENTION: PLEASE READ AND UNDERSTAND ALL INSTRUCTIONS

More information

RITE-HITE TPC. FOAM DOCK SEAL WITH HEAD CURTAIN Installation Instructions & Owner s Manual. Date of Installation:

RITE-HITE TPC. FOAM DOCK SEAL WITH HEAD CURTAIN Installation Instructions & Owner s Manual. Date of Installation: RITE-HITE TPC FOAM DOCK SEAL WITH HEAD CURTAIN Installation Instructions & Owner s Manual Date of Installation: This Manual Covers All Units Shipped 4/08 to Date PRINTED IN U.S.A. PUBLICATION TPC00001

More information

Cabonyx Installation Manual

Cabonyx Installation Manual Cabonyx Installation Manual Content Deck-Nyx and Plan-Nyx Installation Page 1 Flooring Products Page 1 Accessories Page 1 Installation Tools Page 2 Preparing Sub-structure Page 2 Installation Page 4 Cautions

More information

Ulltraclad Aluminium Cladding. Contents. 1.0 General Information Design Information Installation Information 7. 4.

Ulltraclad Aluminium Cladding. Contents. 1.0 General Information Design Information Installation Information 7. 4. Ulltraclad Aluminium Cladding Contents 1.0 General Information 2 2.0 Design Information 4 3.0 Installation Information 7 4.0 Maintenance 10 5.0 Health & Safety 10 1 1.0 General Information 1.1 Introduction

More information

MACHINE TOOL ACCESSORIES

MACHINE TOOL ACCESSORIES VERTICAL 5-C COLLET VISE SERIES 344: VERTICAL 3-C COLLET VISE SERIES 344: : 2-1/2 x 7-3/4 Height: 4 Small movement of lever opens or closes collet. 2030000 CAM OPERATED 5-C HORIZONTAL/VERTICAL COLLET FIXTURE

More information

KEITH PANEL SYSTEMS FUNDERMAX- MAX EXTERIOR EXPOSED FASTENER PRESSURE EQUALIZED WALL SYSTEM

KEITH PANEL SYSTEMS FUNDERMAX- MAX EXTERIOR EXPOSED FASTENER PRESSURE EQUALIZED WALL SYSTEM S Y S T E M D E T A I L S FUNDERMAX- MAX EXTERIOR EXPOSED FASTENER PRESSURE EQUALIZED WALL SYSTEM PAGE TITLE PAGE Table of Contents Fundermax Max Exterior Product Information Design and Installation Information

More information

1200 SERIES 2 PANEL DOOR rev.1 DETAILED INSTALLATION INTRUCTIONS

1200 SERIES 2 PANEL DOOR rev.1 DETAILED INSTALLATION INTRUCTIONS 1200 SERIES 2 PANEL DOOR 10.2013 rev.1 DETAILED INSTALLATION INTRUCTIONS GENERAL: Door elevations shown in these instructions are as viewed from the outside. X denotes the active or moving panel(s). O

More information

Fold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE

Fold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE Fold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE This instruction guide provides the minimum recommended procedures to correctly prepare the rough opening, install a fold-a-way patio door unit and apply

More information

STANDARD STANDARD PRODUCT CATALOG SHEET METAL MACHINERY SHEET METAL MACHINERY

STANDARD STANDARD PRODUCT CATALOG SHEET METAL MACHINERY SHEET METAL MACHINERY STANDARD STANDARD SHEET METAL MACHINERY SHEET METAL MACHINERY PRODUCT CATALOG Standard Sheet Metal Machinery, Inc., is incorporated in Lisbon, Iowa USA. The company speciaizes in sales and service of machinery

More information

TRADE Prices Monday-Friday 7am-5pm. (HETAS Installers ONLY)

TRADE Prices Monday-Friday 7am-5pm. (HETAS Installers ONLY) TRADE Prices 2017 (HETAS Installers ONLY) ex VAT sales@saltfire.co.uk 01929 555211 Monday-Friday 7am-5pm VITREOUS FLUE premium black enamel single skin flue pipe Straight Lengths V5250 250mm 11.99 V5500

More information

Figure 2. Detail of exhaust stack mounting bracket made from sheet metal. The side shown here faces the kiln body and is attached by nine small bolts.

Figure 2. Detail of exhaust stack mounting bracket made from sheet metal. The side shown here faces the kiln body and is attached by nine small bolts. Kiln design The kiln designed here was adapted from the New Hampshire Charcoal Kiln described by Henry Baldwin, New Hampshire State Forester, in 1950. Baldwin s kilns were used extensively in pre-wwii

More information

Door Canopy. PDL Building Products Industrial Parkway, N. Olmsted, OH Phone:

Door Canopy. PDL Building Products Industrial Parkway, N. Olmsted, OH Phone: Door Canopy Door Canopies are attractive and efficient while eliminating the need and expense of drafting and manufacturing canopies as part of the building package. Construction: 26 gauge material around

More information

B3199R - Ceiling Flange B3199RCT - Ceiling Flange Dura-Copper Coated. TOLCO Fig All Steel Ceiling Plate. 216 Eaton

B3199R - Ceiling Flange B3199RCT - Ceiling Flange Dura-Copper Coated. TOLCO Fig All Steel Ceiling Plate. 216 Eaton ttachments 3199R - eiling Flange 3199RT - eiling Flange ura-opper oated Size Range: 3 /8"-16 & 1 /2"-13 rod Material: Malleable Iron (Stainless Steel Type 304 available) Standard 3199RT is UR-OPPER coated

More information

Chapter 12 - Windows and Doors

Chapter 12 - Windows and Doors Chapter 12 - Windows and Doors Contents Chapter 12 - Windows and Doors... 12-1 Timing & Prerequisites... 12-2 Verifying Windows and Doors Orders... 12-3 Windows... 12-4 Prepare the Window Openings... 12-4

More information

ProBuilder Series CoolSmart TV (42PB - sku# )(54PB - sku# )(72PB - sku# )

ProBuilder Series CoolSmart TV (42PB - sku# )(54PB - sku# )(72PB - sku# ) Compatibility ProBuilder Series CoolSmart TV ProBuilder Series Linear Fireplaces (42PB, 54PB & 72PB) Packing List Convection Manifold (with grill and mounting brackets pre-attached) 5 Diameter Aluminum

More information

Installation Guide: NC 25 System

Installation Guide: NC 25 System Installation Guide: NC 25 System Table of Contents INSTALLATION GUIDE: NC 25 SYSTEM 1 PROPER STORAGE AND HANDLING 3 SUITABLE SUBSTRATES 3 FLASHING 3 MOISTURE BARRIER 4 METAL CHANNELS/COMPONENTS 4 STAINLESS

More information