Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS
|
|
- Spencer Logan
- 5 years ago
- Views:
Transcription
1 Safety ontrol Modules for Emergency Stop ircuits Single hannel Emergency Stop Module E-Stop circuits ategory 2 Sliding door protection onveyors / transfer lines Single hannel Emergency Stop Module E-Stop circuits ategory 2 Sliding door protection onveyors / transfer lines Dual hannel Emergency Stop Module E-Stop circuits ategory 4 onveyor / transfer lines Dual hannel Emergency Stop Module E-Stop circuits ategory 4 onveyor / transfer lines Dual hannel Emergency Stop Module E-Stop circuits ategory 4 onveyor / transfer lines ATEGORY 2 ATEGORY 2 22,5 mm x 121 mm x 84 mm/ 0.89 in x 4.77 in x 3.31 in 22,5 mm x 118 mm x 84 mm / 0.89 in x 4.65 in x 3.31 in 100 mm x 121 mm x 74 mm / 3.93 in x 4.76 in x 2.91 in ategory Auxiliary contacts Switching apacity NO 4 A NO 10 A NO 7 A NO 10 A NO 10 A Restart P/B monitoring (number of operations) 35 ms n n n n n 10 6 IP Vdc n n 35 ms n n n n n 10 6 IP Vdc n 15 ms n n n n n n n 0,75 x 10 6 IP Vac/dc n n 25 ms n n n n n n n 10 6 IP Vdc n n 30 ms n n n n n n n 10 6 IP 20 n n 24 Vdc FF-SRS5924 FF-SRS5934 FF-SRS5925 FF-SRS5935 FF-SRS5988 FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS
2 Safety ontrol Modules for Machine Interfacing Two Hand ontrol Interfaces ategory 1 ategory IIIA (EN 574) Hand injury protection e.g. due to dangerous machine movement Robotics Pick and place machines Safety Door Monitor Interfaces ategory 4 Monitors the status of limit switches on a safety door Extension Module Interfaces ategory 4 ontact multiplication: - safety control modules - safety light curtains with relay outputs - other safety devices Extension Module Interfaces ategory 4 ontact multiplication: - safety control modules - safety light curtains with relay outputs - other safety devices TYPE IIIA per EN ,5 mm x 121 mm x 74 mm/ 0.89 in x 4.77 in x 2.91 in 100 mm x 121 mm x 74 mm / 3.94 in x 4.76 in x 2.91 in ategory NO 10 A NO 10 A NO 5 A NO 10 A Switching capacity (number of operations) 2 input channels 30 ms n n n n ,5 s IP Vdc n n 30 ms n n n s IP Vdc n n 35 ms n n 10 6 IP Vac/dc n n 15 ms n n 10 6 IP Vac/dc n n DIN rail mount FF-SR25980 FF-SRD5985 FF-SRE59292 FF-SRE3081 FF-SRE3081 FF-SRE59292 FF-SRD5985 FF-SR25980 The overall safety category depends on the category of the main safety control module, therefore a higher safety category may be reached
3 Safety ontrol Modules for Machine Interfacing ategory Switching capacity Start P/B monitoring Stopped motor indicator (Number of operations) 2 input channels FF-SRT Time Delay Module Time delay before disconnection of safety interface circuits According to Machinery Directive 98/37/E and ATEGORY or 2 1 NO 8 A n 3 x 10 6 IP Vdc n FF-SRT FF-SRST Emergency Stop Module with Timer Time delay before disconnection of safety interface circuits : delayed opening of an interlocked protective gate ategory 3 (direct safety contacts) (delayed safety contacts) Ä NO 5 A 3 Ä 15 ms ± n n n n n n n 10 6 IP Vac/dc n n FF-SRST Standstill Monitor Standstill detection of induction motors Used to unlock a safety door guarding a rotating machine only when the hazardous movement is stopped Used to activate an emergency brake when a e-stop signal is received and while the motion is still present. Standstill and Low Speed Monitor Standstill monitor / low speed monitor for any kind of rotating devices Used to unlock a safety door guarding a rotating machine only when the hazardous movement is stopped Used to activate an emergency brake when an e-stop signal is received and while the motion is still present ATEGORY 1 Directive 98/37/E and ategory NO 8 A 2 N NO 4 A 2 s n n n n 10 6 IP Vdc n 3,2 ms / 8,3 s n n n ,5 s IP Vac/dc n n FF-SR05936 FF-SR05932 FF-SR05932 FF-SR05936 The overall safety category depends on the category of the main safety control module, therefore a higher safety category may be reached. Direct contacts Ä Delayed contacts ± Broken wire detection in measuring inputs 26 27
4 Relay ontrol Modules to be used with ESPE equipment ategory ESPE static outputs compatibility Switching current Equipment Start P/B monitoring Inputs status indicator Restart conditions indicator (Number of operations) 2 input channels FF-SRL59252 ompatible with Honeywell ESPE 22,5 mm x 118 mm x 84 mm / 0.89 in x 4.65 in x 3.31 in 4 2 n 2 NO 7 A 15 ms n n n n n n ³ 7,5 x 10 5 IP Vdc n n FF-SRL59252 FF-SRS59392 ompatible with Honeywell ESPE Æ 4 2 n 2 NO 6 A 15 ms n n n n n n n n ³ ms IP Vdc n n FF-SRS59392 FF-SRL59192 ompatible with Honeywell ESPE 45 mm x 118 mm x 84 mm / 1.77 in x 4.64 in x 3.30 in 4 2 n 3 NO 6 A 15 ms n n n n n n n ³ 10 6 IP Vdc n n FF-SRL59192 Æ Single, not internally redundant contacts ³ between inputs must be performed by the connected ESPE (Electrosensitive Protective Equipment)
5 Safety ontrol Modules to be used with ESPE equipment ategory 4 Muting for onveyor or Machine Applications ompatible with any Honeywell Type 2, Type 3 or Type 4 electrosensitive protective equipment* Accept one muted safety device and one auxiliary safety device (muted or non muted) *with some restrictions (see product installation manual) ategory ESPE static outputs compatibility Switching current 4 2 x 2 n 3 NO 5 A 24 Vdc Switching voltage Override function Test output / output Muting indicator/output s/outputs Restart condition indicator/output Failure diagnotic indicator / output start muting inputs 25 ms n n n n n n n n n n 2 x s 24 Vdc n n (1 A) FF-SRM200P2 New FF-SRM200P
02/11/2015
Standstill monitoring KSW3-JS Part number 85102331 Function "Stillstand detection without sensors" Independent of rotation direction Security with redundancy and feedback circuit 3 forcibly guided "NO"
More informationSAFETY LIGHT CURTAINS
, E E with 30 mm resolution and fixed cascade for hand protection for point of operation guarding on presses E with integrated start/restart interlock for access guarding on transport conveyors Rapid market
More informationonlinecomponents.com
FF-SRE609 Extension Module FF-SR Series FEATURES Complies with the Machinery Directive 98/3/EC Meets the applicable parts of the US & Canadian regulations and standards ANSI/RIA/OSHA Redundant and positive-guided
More information02/11/2015
Emergency stop and safety guard monitoring 2 channels KNE3-YS Part number 85102436 "Emergency stop" & "Safety gates monitoring" functions Single and 2-channel operation Security with redundancy and feedback
More informationMICRO SWITCH Key-Operated Safety Interlock Switch GK Series Issue 1. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS DIFFERENTIATION
MICRO SWITCH Key-Operated Safety Interlock Switch GK Series DESCRIPTION MICRO SWITCH GK Series switches are key-operated safety interlock rugged metal switches which monitor the positions of gates, guards,
More informationCircuit diagram. Applications. Function. Function (Continued) Page 23 SNO 4062K /K-A /KM /KM-A
SNO 4062K Basic unit for emergency stop and guard door applications Basic unit as per DIN EN 60204-1 and EN ISO 13849-1 for single or twin channel emergency stop monitoring. PL e and category 4 as per
More informationElectronic timers CT-S range Selection and ordering details
CT-S range Selection and ordering details Characteristics CT-S range CT-MFS 1SVR 430 010 F 0200 3 multifunction and 21 multi-range Continuous supply voltage range (24-240VAC/DC) or multisupply voltage
More informationOrder/Technical Support Tel: (800) / FAX: (800) /
Key-operated safety interlock switch, plastic Without key locking Switches with plastic body for use on light machinery, without inertia. For use in unstable environments where there is a risk of the guard
More information150 C 30 F B D 8L 152H C 30 F BD 43 8L
ulletin SM - Smart Motor ontrollers atalog Number Explanation Open and Non-ombination F D L a b c d e f g a ulletin Number Solid-State ontroller b ontroller Type SM- c mpere s N F d Enclosure Type Open
More informationIO-DIM4 4-Channel, Digital to Analogue Converters
Page 1 of 5 IO-DIM4 4-Channel, Digital to Analogue Converters Features: Benefits: Input status indication Calibrated output DIN Rail mounting Expands controller input capacity Fault finding LED indication
More informationComponents for safety applications Preventa safety modules
Selection guide Applications Modules For Emergency Stop and limit switch monitoring (modules integrated in Micro PLCs) Conforming to standards Machine IEC 204-, EN 292, EN 48 assemblies EN 60204- Principles
More informationInstallation and Operational Instructions for ROBA -switch Type 017._00.2
Manufacturer s Declaration This product is intended for installation in a machine or system, based on the machine directive 2006/42/EC. It is forbidden to start use of the product until the machine or
More information02/11/2015
Emergency stop and safety guard monitoring 1 channel KNAC3-YS Part number 85103035 "Emergency stop" & "Gate monitoring" functions Single channel operation Security with redundancy and feedback circuit
More informationDatasheet - PROTECT-IE-02
Print - Create PDF - Create EXCEL file 20.04.2011-18:28:57h Datasheet - PROTECT-IE-02 Input expander / PROTECT-IE Input expander Input for up to 4 sensors per interface e.g.: magnetic safety switches type
More informationThree models available: Relay output with 24 VDC power input Relay output with 85 to 250 VAC power input Solid-state output with 24 VDC power input
Cperimeter access guarding Description Explosion Proof BeamSafe Long-ange, Single-Beam Safety Control 4 m (40 ft.) range Four possible transmit codes eliminate crosstalk from multiple units in the same
More informationPositive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Contact expander module for increasing the number of available contacts Approvals Unit features Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous
More informationSAFETY LIGHT CURTAINS
SAFETY LIGHT CURTAINS SOLID-, SOLID-E A reliable and interference-proof safety sensor system is a prerequisite for high system availability and achievement of production targets. At the same time the increasing
More information1000 SERIES INSTALLATION SUPPLEMENT Rev. 7/1/10
1000 SERIES INSTALLATION SUPPLEMENT Rev. 7/1/10 Smartscan Incorporated 33083 Eight Mile Road Livonia, MI 48152 Phone: (248) 477-2900 Fax: (248) 477-7453 SMARTSCAN INCORPORATED Livonia, MICHIGAN 1000 The
More informationRM-3 Mute Module Installation and Operating Manual
RM-3 Mute Module Installation and Operating Manual OMRON STI 0613 PN99634-0010 Rev. G 0 Table of Contents Section 1 Important Safety Warnings........................ page 3 Section 2 Description of RM-3
More informationE-STOP relays, safety gate monitors
Up to Category 2, EN 954-1 Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous Connection options for: E-STOP pushbutton Reset button LED indicator for: Switch status channel
More informationE-STOP relays, safety gate monitors
Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C),
More information1000 SERIES INSTALLATION SUPPLEMENT Rev
1000 SERIES INSTALLATION SUPPLEMENT Rev. 1-1-12 Smartscan Incorporated 33083 Eight Mile Road Livonia, MI 48152 Phone: (248) 477-2900 Fax: (248) 477-7453 SMARTSCAN INCORPORATED Livonia, MICHIGAN 1000 The
More informationOperating instructions Fail-safe delay timer AZS About this document. Content
8 Appendix 8.1 Wiring example...4 8.2 Integral System Diagnostics (ISD)....5 9 EU Declaration of conformity Operating instructions.............pages 1 to 6 Original x.000 / 11.2017 / v.a. - 101126753-
More informationSICK AG WHITE PAPER SAFE ROBOTICS SAFETY IN COLLABORATIVE ROBOT SYSTEMS
SICK AG WHITE PAPER 2017-05 AUTHORS Fanny Platbrood Product Manager Industrial Safety Systems, Marketing & Sales at SICK AG in Waldkirch, Germany Otto Görnemann Manager Machine Safety & Regulations at
More informationNew Products Catalogue 2009 Safety Relays ESR5
www.moeller.net New Products Catalogue 2009 Safety Relays ESR5 u Description Functional safety on machines monitoring with safety relays ESR5 Emergency-stop circuits Monitoring of movable guards with guard
More informationInstallation and Operational Instructions for ROBA -switch Type 017._00.2
OBA -switch Type 017._00.2 Guidelines on the Declaration of Conformity A conformity evaluation has been carried out for the product in terms of the EC Low Voltage Directive 2014/35/ EC and the EMC Directive
More informationHeavy-duty Metal Body Safety Interlock Switch. DIN mounting pattern for globally recognized mounting configuration
C R US Conforms to EN1088, EN292, EN60947-5-1, EN60204-1, EN50041 UL and C-UL listed T4011 Heavy-duty Metal Body Safety Interlock Switch Rugged enclosure the all metal housing and stainless steel actuator
More informationOriginal operating instructions Fail-safe inductive sensor GM504S / / 2010
Original operating instructions Fail-safe inductive sensor GM504S 704070 / 01 06 / 2010 Contents 1 Preliminary note 3 1.1 Explanation of symbols 3 2 Safety instructions 4 2.1 Safety-related requirements
More informationLSUW N1 Muting K BPSG LSUW NSR3-1 K / ULSG LSUW N1 K ULSG3/6 FIESSLER E L E K T R O N I K. Kastellstr Esslingen. Tel.
Tel. 0711/ 91 96 970 Schaltgerät BWS Typ 4 73734 Esslingen Kastellstr.9 detection ammoncez! 14 / 30 mm 22 / 42 mm 29 / 56 mm detection ammoncez! 14 / 30 mm 22 / 42 mm 29 / 56 mm 1 0 0 1 0 0 0 0 1 1 1 1
More informationInstallation and Operating Instructions for Phase Demodulator Type _.2
Guidelines on the Declaration of Conformity A conformity evaluation has been carried out for the product in terms of the EU Low Voltage Directive 2014/35/EU and the Electromagnetic Compatibility (EMC)
More informationNEW. Better Productivity by Standstill and Low-speed Monitoring
NEW Better Productivity by Standstill and Low-speed Monitoring Standstill Monitoring Reduces Extra Waiting Time During Work Problem When a hazardous part has a long inertia, door-lock control using an
More informationS1 Minor (usually reversible) injury S2 Serious (normally irreversible) injury including death
General data Application Classification of a machine in categories acc. to EN 954- The 98/3/EG machinery directive stipulates that every machine must comply with the applicable guidelines and standards.
More informationSAFETY ROBOT SYSTEM. General. All Robot Types KR Robot Controller KR C2 or Higher. Issued: 12 Mar 2004 Version: 00. SicherheitKRC en.
SAFETY ROBOT SYSTEM General All Robot Types KR Robot Controller KR C2 or Higher Issued: 12 Mar 2004 Version: 00 1of 24 e Copyright KUKA Roboter GmbH This documentation or excerpts therefrom may not be
More informationFunctional Safety Application Guide
ENGINEERING TOMORROW Functional Safety Application Guide Encoder-less Safety Functions SLS, SSR using DOLD Frequency Monitor VACON and VLT FC-series vlt-drives.danfoss.com Contents Functional Safety Application
More informationApplying Robotic Technologies to Improve Manufacturing Processes
Applying Robotic Technologies to Improve Manufacturing Processes CrossRobotics.com What Can You Automate? Use Our Expertise to Configure Your Entire Robotic Cell If you ve always thought robotic automation
More informationSafety Technique. Emergency Stop Module With Time Delay BH 5928, BI 5928
Safety Technique safemaster Emergency Stop Module With Time Delay BH 5928, BI 5928 0226419 BH 5928 BI 5928 Function Diagram According to - Performance Level (PL) e and category 4 to E ISO 13849-1 2008
More informationSMARTSCAN INFORMATION
SMARTSCAN INFORMATION SS SLC NOV05 SLC2 and SLC4 SAFETY INDUCTIVE LOOP CONTROLLERS INSTALLATION GUIDE Smartscan Ltd, Pywell Road, CORBY, NN17 5XJ, UK, Tel: +44 (0) 1536 401313, Fax: +44 (0) 1536 268954,
More informationseries. Safety sensor for Palletisers. Features. For Palletiser. 3 Different types available. Active - Passive system and Plug and play
Safety sensor for Palletisers Features For Palletiser has been developed especially for Palletisers and wrapping machine access protection applications. Active - Passive system and Plug and play By using
More informationKentaur Turnstiles Full-height gates
Kentaur Turnstiles Full-height gates Secure Kentaur Turnstiles Versatile Durable Modular The robust Kentaur turnstiles and full-height gates are especially suitable for securing the perimeter of buildings
More informationCrane Control Class 7001
Catalog 17 CONTENTS Description.....................................................Page.................................................. 0 ST DC Static Timer............................................
More informationSafety Light Curtains
Safety Light urtains Slim Design with IP67 Protection Type 4 Response Time 14ms Max. ategory 4 PLe SIL Protection Degree IP6 IP67 Hand Protection (1/08/0) SE4D Safety Light urtains Robust Safety Light
More informationF3SN-A & F3SH-A. Safety Light Curtain & Multiple-beam Safety Sensor
Curtain & Multiple-beam Safety Sensor The Ideal Safety Sensor for Every Application OMRON provides safety two ways: The Curtain and the Multiple-beam Safety Sensor Finger Protection Curtain Operating range:
More informationPower supplies CBC 140-T, CBC 140-1, CBC and CBC 140-5
SM326gb - rev 12/06 S E R V I C E Power supplies CBC 140-T, CBC 140-1, CBC 140-2 and M A N U A L WARNER ELECTRIC EUROPE Rue Champfleur, B.P. 20095, F- 49182 St Barthélemy d Anjou Cedex Tél. +33 (0)2 41
More informationDC-Motor Driver circuits
DC-Mot May 19, 2012 Why is there a need for a motor driver circuit? Normal DC gear-head motors requires current greater than 250mA. ICs like 555 timer, ATmega Microcontroller, 74 series ICs cannot supply
More informationApplying Robotic Technologies to Improve Manufacturing Processes
Applying Robotic Technologies to Improve Manufacturing Processes CrossRobotics.com What Can You Automate? Use Our Expertise to Configure Your Entire Robotic Cell If you ve always thought robotic automation
More informationTransmitter Site Ops
The Broadcasters Desktop Resource www.thebdr.net edited by Barry Mishkind the Eclectic Engineer Transmitter Site Ops Giving Attention to Coax Switchers By Dennis Heymans [October 2012] If your main transmitter
More informationFF-SB Series. Type 4 self-contained light curtain For the protection of operators in Industry FF-SB
Type 4 self-contained light curtain For the protection of operators in Industry FEATURES Meets applicable parts of US OSHA 29CFR 1910.217, 1910.212 and ANSI B11.1, B11.2, B11.19 1990 and RIA 15.06 regulations
More informationSafety Technique. SAFEMASTER Emergency Stop Module With Time Delay BH 5928, BI 5928
Safety Technique SAFEMASTER Emergency Stop Module With Time Delay BH 5928, BI 5928 0226419 BH 5928 BI 5928 Function Diagram According to - Performance Level (PL) e and category 4 to E ISO 13849-1 2008
More informationOriginal operating instructions Fail-safe inductive sensor GG507S / / 2013
Original operating instructions Fail-safe inductive sensor GG507S 80005283 / 00 05 / 2013 Contents 1 Preliminary note...3 1.1 Explanation of symbols...3 2 Safety instructions...4 2.1 Safety-related requirements
More informationF3SJ-B. Safety Light Curtain. Basic Type with a combination of performance and functionality. Ordering Information. Main Units Safety Light Curtain
Safety Light Curtain 3SJ- asic Type with a combination of performance and functionality Up to three sets of series-connected sensors. The muting function is enabled simply with Muting Key Cap. Comes standard
More informationIndustrial motor controller for brushed DC motors 24 VDC
Industrial motor controller for brushed DC motors 24 VDC Design for output currents up to 5 A Control with the following functions: - reversal of direction of rotation - open-loop speed control (external)
More informationSOLID STATE RELAY RATINGS
Solid State Relays SOLID STATE RELAY RATINGS PART NUMBER HPR48A25 HPR48A50 HPR48A75 3PSS60A75 HPR48D25 HPR48D50 HPR48D75 Rated operational current AC51 @ Ta=25 C 25 AMPS rms 50 AMPS rms 75 AMPS rms 75
More informationInstallation and Operational Instructions for ROBA -multiswitch Type 019._00.2
Guidelines on the Declaration of Conformity A conformity evaluation has been carried out for the product in terms of the EU Low Voltage Directive 2014/35/ EU and the Electromagnetic Compatibility (EMC)
More informationProduct Information. EBI 1135 Absolute Rotary Encoder, Multiturn Feature via Battery-Buffered Revolution Counter
Product Information EBI 1135 Absolute Rotary Encoder, Multiturn Feature via Battery-Buffered Revolution Counter December 2012 EBI 1135 Inductive rotary encoder without integral bearing for integration
More informationHUMAN SAFETY IN ROBOT APPLICATIONS REVIEW OF SAFETY TRENDS
1. Tanja KEREZOVIĆ, 2. Gabor SZIEBIG, 3. Bjørn SOLVANG, 4. Tihomir LATINOVIC HUMAN SAFETY IN ROBOT APPLICATIONS REVIEW OF SAFETY TRENDS 1-4. FACULTY OF MECHANICAL ENGINEERING, BANJA LUKA, BOSNIA & HERZEGOVINA
More informationZ07- SWING GATE HOME AUTOMATION. zero Z07 - SWING GATE MOTOR SUPPLY V HOME AUTOMATION IT EN FR Z07.REV USER MANUAL AND CONFIGURATION PG1
Z07- SWING GATE Z07 - SWING GATE MOTOR SUPPLY 230-24V IT EN FR Z07.REV01.2018 USER MANUAL AND CONFIGURATION PG1 Z07 - SWING GATE PG2 Z07- SWING GATE INDEX 01. SAFETY INSTRUCTIONS 02. OPERATOR TECHNICAL
More informationIndustrial motor controller for brushed DC motors 12 VDC
Industrial motor controller for brushed DC motors 12 VDC Design for output currents up to 5 A Control with the following functions: - reversal of direction of rotation - rotational speed control (external)
More informationCurrent consumption ma solenoid current consumption ( max 300 ma) Hz % V ma. Housing dimensions mm 120(d) x 99(h) x 23(w)
89 610/112 ED EWM-A-SV ANALOG AMPLIFIER CARD SERVOVALVE CONTROL RAIL MOUNTING TYPE: DIN EN 50022 OPERATING PRINCIPLE This card is designed for a dynamic control of servovalves with the current output controlled
More informationELECTRICAL INDUSTRIAL INSTALLATIONS
INTRODUCTION A professional Electrician must provide a safe and reliable electrical service to ensure that all work is in accordance with the relevant National rules. This includes assembling, installing,
More informationOptions M-12 quick-disconnect connector. MTS (Machine Test Signal) Muting through RM-3 module Explosion-proof versions available
perimeter access guarding P00 ev..0 S S Description P00 Perimeter ccess Guarding Device Operating range of 0 m Three scan codes to eliminate cross-talk Short/long operating range selector switch esponse
More informationE-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
More information2 or 4 pole changeover contact Plug-in/Faston 187
56 Miniature power relays 56 Plug-in - Power relay, & 4 pole Flange mount option - (Faston 87, 4.8 x 0.5 mm termination) C coils & DC coils Lockable test button and mechanical flag indicator Cadmium Free
More informationComponents for safety applications
Metal, turret head, types CS-A, CS-C and CS-E Double insulated, turret head, types CS-PA, CS-TA and CS-TE Presentation Metal, types CS-A, CS-C, CS-E Switches with or without locking of the actuator Pages
More informationEMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004
Current Monitoring Relay Data Sheet 08/2004 Functions Structure Current monitoring of direct and alternating current in 1-phase networks with settable threshold values, starting override and response delay
More informationWHITE PAPER ELECTRO-SENSITIVE PROTECTIVE DEVICES (ESPE) FOR SAFE MACHINES
WHITE PAPER ELECTRO-SENSITIVE PROTECTIVE DEVICES (ESPE) FOR SAFE MACHINES OPTO-ELECTRONIC PROTECTIVE DEVICES, 2017-08 AUTHORS Otto Goernemann Manager Machine Safety & Regulations at SICK AG, Waldkirch/Germany
More informationServomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16
MZ Servomotor for butterfly valves VF, VFH delta-elektrogas.com EE157-01/16 MZ Servomotor Contents Description.... 2 Features........ 2 Functioning and application..... 3 Technical specifications......
More informationOperating Instructions for Control CS 500
Operating Instructions for Control CS 500 GB CS 500 Gate Controls / Rev.A 5.0 1 1. Contents 1. Contents 2 2. Information in this document 2 3. General safety instructions 3 4. Overview of products 4 5.
More informationPower supply CP-E 24/0.75
2CDC 271 016 F0t06 a OUTPUT L+, L : terminals output b INPUT L, N, PE: terminals input c LOW: red LED output voltage too low d OK: green LED output voltage OK e OUTPUT Adjust: rotary potentiometer output
More informationPOWER RELAYS CONTINUOUS DUTY, TYPE II, UNSEALED INTERMITTENT DUTY, TYPE III, UNSEALED
POWR RLYS INUOUS DUTY, TYP II, UNSLD INTRMITTNT DUTY, TYP III, UNSLD General Specifications Designed to MIL-R- - Type II Unsealed ontinuous Duty - Type III Unsealed Intermittent Duty - overed/gasketed
More informationIndustrial motor controller for brushed DC motors 24 VDC
Industrial motor controller for brushed DC motors 24 VDC Design for output currents up to 5 A Control with the following functions: - reversal of direction of rotation - open-loop speed control (external)
More informationVAC V AC/DC, +/-10%, 45-65Hz Hz VDC max 1W ; 24VAC 2.5VA, 48VAC 4.46VA ; 110VAC 1.76 VA ; 220VAC 2.53 VA
DIN imers D 17.5mm or 22.5mm DIN rail mounting Electronic imers Wide coil operation, 24V to 320V AC/DC (from 12V with DMD-X) Multi ime range / Multi function ON-Delay, OFF-Delay, Asymetrical, Star/Delta
More informationABB AC Brushless Servodrives Manual of the Safety Relay Board
ABB Servomotors ABB AC Brushless Servodrives DGV 700 Converters for Speed, Torque and Positioning Control of Brushless AC Permanent Magnet Servomotors Manual of the Safety Relay Board ABB AC Brushless
More information02/11/2015
Two-hand safety relays KZH3-YS Part number 85102632 "Two-hand" safety function in with two push buttons Inputs for two switches with double contacts (1 NO and 1 NC for each) Security with redundancy and
More informationCircuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You
Circuit Breakers Excerpt from Master Catalogue Circuit Breakers Specifically For You Hydraulic-magnetic technology ensures reduced nuisance tripping with temperature variance Always holds 00% rated current
More informationTimers RTE. RTE Series Analog Timers
RTE RTE Key features: 20 time ranges and 10 timing functions Time delays up to 600 hours Space-saving package High repeat accuracy of ± 0.2% ON and timing OUT LE indicators Standard 8- or 11-pin and 11-blade
More information2 pole (1 NO + 1 NC) 1 NO + 1 NC 2 NO + 2 NC, 3 NO + 1 NC 4 NO + 2 NC Rated current / Max. peak current Rated load AC1
Features 7S.12...5110 7S.14...0220/0310 7S.16..0420 Relay module with forcibly guided contacts 7S.12 with 2 pole (1NO + 1 NC) 7S.14 with 4 pole (2 NO + 2 NC and 3 NO + 1 NC) 7S.16 with 6 pole (4 NO + 2
More information60 mm sq. (2.36 inch sq.)
6 mm sq. (.36 inch sq.) 1.8 /step RoHS Unipolar winding, Connector type Unipolar winding, Dimensions for attaching NEMA3 are interchangeable (47.14 mm-pitch) Bipolar winding, Connector type p. 76 Bipolar
More informationSubpart O - Machine Guarding
Subpart O - Machine Guarding We Will Cover: Machine Guarding Principles Subpart O - Highlights Mock Plant Walk-Through Why are machines not guarded? No one would stick their arm, hand, finger, head, etc.
More informationSMARTSCAN 8000 SERIES LIGHT CURTAIN Series Safety Light Curtain Installation Sheet (CD159/030210)
SMARTSCAN 8000 SERIES LIGHT CURTAIN 1 8000 Series Safety Light Curtain Installation Sheet (CD159/030210) Figure A - Unpacking Remove all packaging material and retain it Locate and keep the delivery note
More informationRobot e.do. Safety requirements and technical specifications. Rel axes and 6 axes versions
Robot e.do Rel. 00-4 axes and 6 axes versions Safety requirements and technical specifications Requirements and instructions for safe installation, use, and decommissioning of the Robot. Robot Technical
More informationZelio Control Measurement Relays
Selection Guide Application Voltage control Current control Functions 3-phase Single-phase and d.c. Integrated current transformer - Overvoltage and between phases - Overvoltage and between phases and
More informationSafety Standards and Collaborative Robots. Pat Davison Robotic Industries Association
Safety Standards and Collaborative Robots Pat Davison Robotic Industries Association Topics What is it? How did we get here? What has already been done? What still needs doing? Standards ISO 10218-1:2006
More informationElectronic timer CT-SDE
CDC 51 059 F000 1 Characteristics " 1 single time range from 0. to 0 s " versions with different supply voltage ranges are available: 4 AC/DC and 110-10 AC and 80-415 AC " Single-function timer with star-delta
More informationInsulation coordination (EN ) Standards EN Note 24 V DC / 24 V DC 0,1 A. 230 V AC ±10% Power rating 24 V DC ±20 % 140 mw
Optos - MIROSERIES MOS / MOZ 3 48 V D / 0.1 A Universal interface between control and sensor/actuator Plug-in cross-connection ZQV 4N Interchangeable solid-state relay 6.1 mm wide Screw or tension clamp
More informationPHOENIX CONTACT - 09/2009
Electronic miniature circuit-breaker CLIPLINE Data sheet 03906_en_0 PHOENIX CONTACT - 09/2009 Description The EC-E... electronic miniature circuit-breaker selectively protects all 24 V DC load circuits
More informationEC 45 flat with integrated electronics Document ID: en Operating Manual
EC 45 flat with integrated electronics Document ID: 919801en Operating Manual Edition June 2017 The EC 45 flat with integrated electronics is a brushless, speed-controlled 1-quadrant drive. It is available
More informationPower supply CP-E 24/2.5
2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment
More information8000 Series Safety Light Curtain Installation Sheet ( CD159/ )
SMARTSCAN 8000 SERIES LIGHT CURTAIN 1 8000 Series Safety Light Curtain Installation Sheet ( CD159/040305 ) Unpacking Remove all packaging material and retain it Locate and keep the delivery note Inspect
More informationPower Distribution System SVS18
Power Distribution System SVS8 Description The power distribution system SVS8 optimises the DC V distribution in automation and process control, in the production area of the chemical industry and in power
More information62 Series - Power relays 16 A. Features / /
6 Series - Power relays 6 A Features 6. / 6.3 6.-0300 / 6.3-0300 Printed circuit mount 6 A Power relay & 3 Pole changeover contacts or NO ( 3 mm contact gap) AC coils & DC coils Reinforced insulation between
More informationThe way through the standard Questions and answers on EN ISO 14119:2013
EN The way through the standard Questions and answers on 14119:2013 1 Table of contents Page Introduction 3 Flowchart 4 Selection of an interlocking device with or without guard locking Must a guard locking
More informationContent. Monitoring relay pluggable. 1-phase current monitoring relay phase direct-current voltage monitoring relay... 5.
Content Monitoring relay pluggable 1-phase current monitoring relay... 5.2 1-phase direct-current voltage monitoring relay... 5.6 1-phase voltage monitoring relay... 5.10 3-phase voltage monitoring relay...
More informationPower supply CP-E 24/20.0
2CDC 271 027 F0008 a OUTPUT L+, L+, L, L-: terminals output b INPUT L, N, PE: terminals input c 13-14: terminals - signalling contact d OUTPUT OK: green LED output voltage OK e OUTPUT LOW: red LED output
More informationPID500 FULL FEATURED PID TEMPERATURE CONTROLLERS
PID500 FULL FEATURED PID TEMPERATURE CONTROLLERS DESCRIPTION FEATURES * Compact Size: 1/16 DIN * Dual LED displays for simultaneous indication of process temperature and set point (Lower display selectable
More informationEMD-FL-3V Phase Voltage Monitoring Relay INTERFACE. Data Sheet. Description
3-Phase Voltage Monitoring Relay INTERFACE Data Sheet PHOENIX CONTACT - 03/2006 Description Voltage monitoring in 3-phase networks with settable threshold values, settable response delay, monitoring of
More informationBlue Point Engineering
Blue Point Engineering Instruction I www.bpesolutions.com Pointing the Way to Solutions! Puppet - II+ Controller (BPE No. PCA-0001) Servo Position Adjustment EEPROM Digital Button Power 5 Vdc Playback
More informationDATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection
DATASHEET - ETR4-70-A Delivery program Timing relay, 2W, 0.05s-100h, multi-function, 24-240VAC/DC, potentiometer connection Part no. ETR4-70-A Catalog No. 031888 Eaton Catalog No. XTTR6A100H70B EL-Nummer
More informationInstruction manual for STA 1 sectional door operator
Instruction manual for STA 1 sectional door operator Sectional door operator STA 1 / Rev. 0.3 1 GB 1. Contents 3. General safety instructions 1. Contents 2 2. Key to symbols 2 3. General safety instructions
More informationP RODUCT C ATALOGUE 1/2002
S a f e t y R e l a y s S e r i e s U E 1 0-4 8 P RODUCT C ATALOGUE 1/2002 For technical details please unfold 2 SICK Industrial Safety Systems Germany All rights reserved 8 009 607/30-03-02 UE 10 UE 48
More informationTrusted Speed Monitor Input FTA (SIFTA)
PD-T8846 Trusted Product Overview The Trusted Speed Monitor Input Field Termination Assembly (SIFTA) is a DIN rail assembly. It provides the input field interface for three rotating machine groups when
More information