Three models available: Relay output with 24 VDC power input Relay output with 85 to 250 VAC power input Solid-state output with 24 VDC power input

Size: px
Start display at page:

Download "Three models available: Relay output with 24 VDC power input Relay output with 85 to 250 VAC power input Solid-state output with 24 VDC power input"

Transcription

1 Cperimeter access guarding Description Explosion Proof BeamSafe Long-ange, Single-Beam Safety Control 4 m (40 ft.) range Four possible transmit codes eliminate crosstalk from multiple units in the same area Signal strength indicator allows easy installation No interconnecting cables required, which speeds longrange installations Three models available: elay output with 4 VDC power input elay output with 8 to 0 VAC power input Solid-state output with 4 VDC power input Switch-selected Automatic Start or Start/estart Interlock operation Lens heater The BeamSafe is a longrange single-beam safety control designed for perimeter and access guarding in an explosive environment. Diverse redundant microprocessor design provides safe, control-reliable operation. A BeamSafe system consists of one transmitter and one receiver. No interconnecting cables or separate control are required. Mounted on the receiver, four separate visible indicators provide instant information on system clear, blocked or interlocked status as well as signal strength. Output options include redundant solid-state or force-guided relays located in the receiver. When ordering, it is necessary to specify model numbers for transmitter, receiver and enclosure(s). Immunity to weld flash and ambient light are enhanced by coding the infrared beam. This feature also eliminates interference from other BeamSafe units installed in close proximity. A tight beam angle reduces problems associated with reflective surfaces. BeamSafe II is designed in accordance with IEC 49, EN 94- and ANSI B.9-00 A Go to the Engineering Guide For in-depth information on safety standards and use. C USA Tel. /888/0-47 Canada Tel. /800/-700 UK Tel. +44 (0) Europe Tel. +49 (0) Japan Tel China Tel Singapore Tel

2 perimeter access guarding Enclosure Transmitter and receiver enclosures rated for Class I, Group C and D explosive environments Sandblasted natural finish Designed to meet UL88; NEC articles 00, 0 and 0; CSA NEMA 4X Sold separately from BeamSafe II electronics Applications Industries such as chemicals, agriculture, waste water, printing, distilling, pharmaceuticals, and cosmetics have hazardous process locations. Specifications Performance Protected Height: Single Beam Operating ange: 0. to 4 m ( to 40 ft.) when used in explosion-proof enclosure Beam Diameter: mm (. in.) Maximum esponse Time: <0.0 sec. for all models DC Models Input Power: 4 V ±0% (negative ground) eceiver/elay Output: 0.4 A Max eceiver/ss Output: 0.80 A Max Transmitter: 0.7 A Max AC Models Input Power: 00 to 0 VAC ±0%, 0/0 Hz; eceiver VAC: VA eceiver 0 VAC: VA Transmitter VAC: 0. VA Transmitter 0 VAC: 0 VA Effective Aperture Angle:. maximum half angle Frequency Selection: 4 non-interfering codes, all models Diagnostics: Built-in diagnostic indicators Output: elay Output Version: Two relays with force-guided contacts, NO rated 4 A at VAC, 00 W switched power (.0 kva). DC Loads are limited to 00 V maximum. Estimated mechanical life is 0,000,000 operations. Electrical life is typically,000,000 operations at 00 VA. Auxiliary Monitoring elay: 400 VAC/DC maximum, 0. A; total power 80 mw maximum. Solid-State Output Version: Two safety solid-state relay outputs. Each output sources (PNP) up to 0. A at 4 VDC. Construction: Cast aluminum, natural finish Operating Temperature: 0 to C ( to F) Weight: Approx. kg ( lbs.) Protection Category: IP; NEMA 4X Agencies: BeamSafe II is designed in accordance with IEC 49, type 4 and UL/CSA requirements. BSEP Enclosure Conformity/Approvals Conforms to: N.E.C. Class I, Groups C & D; Class II, Groups E, F & G; Class III; Enclosure NEMA, 4X, 7 & 9 Approvals: UL Classified - Standard 0, CSA Certified Standard C. no. 0-M984 Specifications are subject to change without notice. C Perimeter Guarding Shown here with one transmitter and receiver. Mirrors are used to form two beams and also turn corners. to 4 ft 0. to. m Long-ange Perimeter Guarding Two transmitter/receiver pairs using two mirrors and STI mounting stands to direct the beam around a corner. to ft 0. to 7 m Double Bounce This configuration guards access to hazardous work cells. One transmitter and receiver combined with two STI 4-inch mirrors and mounting brackets. to ft 0. to m Transmitter in 900 mm Transmitter in 900 mm eceiver Transmitter in 900 mm 4 Mirror eceiver Floor in 400 mm Transmitter Floor in 400 mm eceiver eceiver Floor in 400 mm 4 Mirror USA Tel. /888/0-47 Canada Tel. /800/-700 UK Tel. +44 (0) Europe Tel. +49 (0) Japan Tel China Tel Singapore Tel C

3 Cperimeter access guarding Dimensions in./mm WINDOW TX DETECTION BEAM WINDOW FO BS BEAM (ON EITHE END) X WINDOW TX & X MTG SHOWN IS EPESENTATIVE ONLY VAIABLE MOUNTING HOLES FO ADJUSTABLE MOUNTING LOCATIONS C L Mtg. C L 8..9 C L Mtg..00 WINDOW FO BS BEAM ( PLCS) THEADED HOLE TO ACCEPT /4" NPT PIPE FITTING A Go to the Engineering Guide For in-depth information on safety standards and use. C4 USA Tel. /888/0-47 Canada Tel. /800/-700 UK Tel. +44 (0) Europe Tel. +49 (0) Japan Tel China Tel Singapore Tel

4 perimeter access guarding Wiring Two Normally Open Contacts AC Voltage Connections BSAC Earth/Ground to 0 VAC MPCE MPCE To Machine Control Stop Circuit C J J7 Output A Output B Auxiliary Monitor elay (Non Safety Output) (N.C.) Start MPCE MPCE No external voltage is to be applied to terminals &. Damage to unit will occur. WANING: Arc suppression devices should only be installed across the coils of the machine control relays. Never install Arc Suppression devices directly across the control output contacts of the BeamSafe. An arc suppression device installed across the contacts may fail with a short circuit and will result in an unsafe condition. These relay contacts must be forceguided contacts. User supplied over current protection, 4A max. Normally Open/Normally Closed Connection Diagram BSAC 00 to 0 VAC MPCE MPCE Earth/Ground 7 8 To Machine Control Stop Circuit J J7 Output A Output B Auxiliary Monitor elay (Non Safety Output) (N.C.) Start MPCE MPCE No external voltage is to be applied to terminals &, Damage to unit will occur. WANING: Arc suppression devices should only be installed across the coils of the machine control relays. Never install Arc Suppression devices directly across the control output contacts of the BeamSafe. An arc suppression device installed across the contacts may fail with a short circuit and will result in an unsafe condition. These relay contacts must be forceguided contacts. User supplied over current protection, 4A max. USA Tel. /888/0-47 Canada Tel. /800/-700 UK Tel. +44 (0) Europe Tel. +49 (0) Japan Tel China Tel Singapore Tel C

5 Cperimeter access guarding Wiring (continued) Two Normally Open Contacts DC Voltage Connections (Solid-State Output Model) BSC4 Earth/Ground VDC MPCE MPCE To Machine Control Stop Circuit J Sourcing Output A Output B Start (N.C.) Signal eturn 4 Two Normally Open Contacts 4 VDC Voltage Connections MPCE MPCE No external voltage is to be applied to terminals 4 & ; Damage to unit will occur. WANING: Arc suppression devices should only be installed across the coils of the machine control relays. Never install Arc Suppression devices directly across the control output contacts of the BeamSafe. An arc suppression device installed accros the contacts may fail with a short circuit and will result in an unsafe condition. These relay contacts must be force guided contacts. If load is less than 0 ma a resistor must be installed across the load. BS4 4 VDC MPCE MPCE J Earth/Ground To Machine Control Stop Circuit J J Output A Output B Auxiliary Monitor elay (Non Safety Output) (N.C.) Start 4 4 MPCE MPCE No external voltage is to be applied to terminals 4 &. Damage to unit will occur. WANING: Arc suppression devices should only be installed across the coils of the machine control relays. Never install Arc Suppression devices directly across the control output contacts of the BeamSafe. An arc suppression device installed accros the contacts may fail with a short circuit and will result in an unsafe condition. These relay contacts must be forceguided contacts. User supplied over current protection, 4A max. A Go to the Engineering Guide For in-depth information on safety standards and use. C USA Tel. /888/0-47 Canada Tel. /800/-700 UK Tel. +44 (0) Europe Tel. +49 (0) Japan Tel China Tel Singapore Tel

6 perimeter access guarding Accessories mm/in. Front Surface Glass or Stainless Steel Mirror MI4-FG and MI4-SS MI4BKT C MIO STAINLESS STEEL O GLASS MIO SUPPOT BLOCK MIO STAND PIPE 8..0 MOUNTING TABS (4 PLACES) BSMK O USA Tel. /888/0-47 Canada Tel. /800/-700 UK Tel. +44 (0) Europe Tel. +49 (0) Japan Tel China Tel Singapore Tel C7

7 Cperimeter access guarding Accessories mm/in. (continued) Adapter Kit ESBKT (INCLUDES ADAPTES ONLY) ADAPTE LCMK-4 MIO MIN ADAPTE Laser Alignment Tool BSLA Laser Level Unit Target Clip BEAMCHECK BeamSafe II BeamSafe II Laser Mounting Adaptor A Go to the Engineering Guide For in-depth information on safety standards and use. C8 USA Tel. /888/0-47 Canada Tel. /800/-700 UK Tel. +44 (0) Europe Tel. +49 (0) Japan Tel China Tel Singapore Tel

8 perimeter access guarding Ordering To configure a complete system, order one BSX transmitter, one BS receiver, and one BSEP explosion-proof enclosure for each transmitter and one for each receiver requiring explosion-proof capability. Users should provide their own signal and power wiring. Quick disconnect cables sold as an option for the BeamSafe II will not work with the explosion-proof enclosure. Model No. Description* BSX4 Transmitter, 4 VDC BSXAC Transmitter, 8 to 0 VAC, 0/0 Hz BSXC4 Transmitter, 4 VDC, Compact Size BS4 eceiver, 4 VDC, elay Output BSAC eceiver, 8 to 0 VAC, 0/0 Hz, elay Output BSC4 eceiver, 4 VDC, Compact Size, Solid-state Output BSEP BeamSafe enclosure (BeamSafe II electronics are sold separately.) *System Shipping Weight:.4 kg/ lb. For information on esource Modules, see page D00 For information on STI safety light curtain accessories, see page D48 Safety Standards and Precautions The BeamSafe II meets applicable OSHA, ANSI and IA standards and was designed in accordance with IEC 49, DIN EN 000 and EN 94-. Only use the BeamSafe on machinery that stops consistently and immediately anywhere in its cycle or stroke. Never use a BeamSafe on a full-revolution clutched press or machine. The BeamSafe is a single optical beam, not a curtain of light. Therefore it is not designed for use as a point-of-operation device. If one or more BeamSafe systems do not protect all access to the hazardous machine area, the unprotected access must be guarded by fencing, barriers or other appropriate methods. The purchaser, installer and employer are responsible for meeting all appropriate laws, rules and regulations relating to the proper use, installation, operation and maintenance of this control and the guarded machine. All application examples described are for illustration purposes only. Actual installation will differ from those indicated. Installation Notes Because explosion-proof housings offer a smaller range of adjustment than standard STI mounting brackets, the installation and alignment of transmitters and receivers is a process requiring attention to detail. The mounting hardware of the BeamSafe II transmitter and receiver inside the enclosures has adjustment screws which allow a small amount of rotational adjustment. Transmitter and eceiver Cable Warning Transmitter and receiver cables are not supplied with the BeamSafe system. Wiring the transmitter and receiver must be done in accordance with all local, state and federal government laws, rules, codes or regulations relating to the proper use, installation and operation of this control and the guarded machine. Hybrid Systems An application may exist where it is not necessary for the entire single beam system to be in the hazardous area. In this case, order only one explosion-proof enclosure. C USA Tel. /888/0-47 Canada Tel. /800/-700 UK Tel. +44 (0) Europe Tel. +49 (0) Japan Tel China Tel Singapore Tel C9

Options M-12 quick-disconnect connector. MTS (Machine Test Signal) Muting through RM-3 module Explosion-proof versions available

Options M-12 quick-disconnect connector. MTS (Machine Test Signal) Muting through RM-3 module Explosion-proof versions available perimeter access guarding P00 ev..0 S S Description P00 Perimeter ccess Guarding Device Operating range of 0 m Three scan codes to eliminate cross-talk Short/long operating range selector switch esponse

More information

MiniSafe Light Curtains

MiniSafe Light Curtains r Safety Light Curtains MS600 MS600 MiniSafe Light Curtains Resolution: mm (0. in.), 9 mm (0.7 in.) or 0 mm (.8 in.) resolution Range: 7. m ( ft.) range for the mm resolution, 0 m (6 ft.) range for the

More information

Laser Displacement Sensor 3Z4M

Laser Displacement Sensor 3Z4M Laser Sensor High Resolution to 1 µ or 5 µ, Gives Precise Linear Output and Displays Distance Distance is displayed in millimeters on controller Ready-to-use linearized output is both -1 to +1 VDC and

More information

Universal Voltage Cabled Photoelectric E3JK

Universal Voltage Cabled Photoelectric E3JK Universal Voltage Cabled Photoelectric Small Cable Sensor with Complementary Outputs Universal AC/DC supply voltage Relay or NPN/PNP transistor output, light-on or dark-on operation Polarized retroreflective

More information

Limit Switch Style Inductive Prox

Limit Switch Style Inductive Prox Limit Switch Style Inductive Prox Economical, Limit Switch Style Sensor with Plastic Body Low cost Wide operating voltages (10 to 0 VDC and 90 to 250 VAC) Directly switches AC loads up to 500 ma, DC loads

More information

Specifications. Environmental. Operating Temperature [C (F)] for TRIAC output ( ) for all others

Specifications. Environmental. Operating Temperature [C (F)] for TRIAC output ( ) for all others Specifications Environmental Line Line Green Line Analog ertifications UL Listed, SA Approved, and E Marked for all applicable directives Features S Wide selection for increased application flexibility

More information

Specifications. Environmental. Operating Temperature [C (F)] for TRIAC output ( ) for all others

Specifications. Environmental. Operating Temperature [C (F)] for TRIAC output ( ) for all others Specifications Environmental Line Line Green Line Analog ertifications UL Listed, SA Approved, and E Marked for all applicable directives Features S Wide selection for increased application flexibility

More information

Spring Return DuraDrive Proportional Actuator

Spring Return DuraDrive Proportional Actuator MS40-7043, MS4-7073, MS4-753 Spring Return DuraDrive Proportional Actuator For spring return applications that require proportional modulation control of dampers and valves in HVAC systems. Features: Proportional

More information

Non-Spring Return EconoDrive Proportional Actuator

Non-Spring Return EconoDrive Proportional Actuator MSD-0x3 Series Non-Spring Return EconoDrive Actuator EconoDrive overshaft actuators are designed to provide an economical and reliable solution for many overshaft damper and ball valve requirements. All

More information

FF-SB Series. Type 4 self-contained light curtain For the protection of operators in Industry FF-SB

FF-SB Series. Type 4 self-contained light curtain For the protection of operators in Industry FF-SB Type 4 self-contained light curtain For the protection of operators in Industry FEATURES Meets applicable parts of US OSHA 29CFR 1910.217, 1910.212 and ANSI B11.1, B11.2, B11.19 1990 and RIA 15.06 regulations

More information

SALES SERVICE +358 (0)

SALES SERVICE +358 (0) SALES SERVICE +358 (0)17 262 3555 info@econosto.fi ADCATROL ELECTRO-PNEUMATIC POSITIONERS PE 986 (ATEX) DESCRIPTION The ADCATROL PE986 positioner requires an input signal of 4 20 ma for proportional control

More information

SF4-AH SERIES. Small Light Curtain Type 4. Compact size of mm in Type 4 light curtain ORDER GUIDE.

SF4-AH SERIES. Small Light Curtain Type 4. Compact size of mm in Type 4 light curtain ORDER GUIDE. 569 PHOTO PHOTO Small Curtain Type 4 SF4-AH SERIES Related Information General terms and conditions... P.1 SF-AC... P.588 Glossary of terms... P.983 ~ General precautions... P.986 ~ Conforming to Machine

More information

COMMERCIAL. GA Series - Actuator Operating Instructions. GA Non-Spring Return Actuator - (GA24-562) 04/08 /15

COMMERCIAL. GA Series - Actuator Operating Instructions. GA Non-Spring Return Actuator - (GA24-562) 04/08 /15 COMMERCIAL Bray Controls Commercial Diision 13788 West Road, Suite 200A Houston, Texas 77041 BCDSales@Bray.com Phone: 1-888-412-2729 Fax: 1-888-412-2720 www.braycommercialdiision.com GA Series - Actuator

More information

Safety detection solutions Preventa

Safety detection solutions Preventa Characteristics Light curtain type XUS LPpppp Environmental characteristics Conformity to standards ANSI/RIA R15.06, ANSI B11:19-1990, OSHA 1910.217(C), OSHA 1910.212, EN/IEC 61496-1-2 for type 4 ESPE

More information

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution Features Robust, compact housing Two bearings with large distance, one at each end High shaft load up to 450 N Shock resistant up to 250 g Shaft insulation up to 2.8 kv Highest operating speed 10000 rpm

More information

Electro-Magnetic Flowmeters COPA-XE

Electro-Magnetic Flowmeters COPA-XE Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates

More information

MLV40 Series Miniature Sensors

MLV40 Series Miniature Sensors MLV4 Series Miniature Sensors Diffuse Mode See page 54 Features: Adjustable sensitivity Complementary outputs Sensing Range: 5 mm Outputs: NPN, PNP Thru-Beam Mode See page 57 Rugged metal housing Compact

More information

Sensing method Through-beam Retroreflective Diffuse reflective Convergent-beam Appearance Side-view Flat Side-view Flat Side-view

Sensing method Through-beam Retroreflective Diffuse reflective Convergent-beam Appearance Side-view Flat Side-view Flat Side-view R Subminiature Photoelectric Sensor Omron s Next Generation of Sub-miniature Photoelectric Sensors H Utilizes Omron s Hyper LED technology to achieve the industry s smallest visible red beam H Self-contained

More information

Laser Displacement Sensor Z4M. Ordering Information

Laser Displacement Sensor Z4M. Ordering Information Laser Displacement Sensor Compact Displacement Sensor with 1.5-micron Resolution Offers Long-distance Measurement for In-line Production Inspection High resolution with 3 user-selectable response speed

More information

Non-Spring Return DuraDrive Modulating Actuator

Non-Spring Return DuraDrive Modulating Actuator MS41-60xx Series n-spring Return DuraDrive Modulating Actuator The DuraDrive direct coupled 24 Vac non-spring return rotary electric actuators are designed for modulating control of dampers. S41-60xx ries

More information

Echotel Model 910 Ultrasonic Level Switch

Echotel Model 910 Ultrasonic Level Switch Echotel Model 910 Ultrasonic Level Switch D E S C R I P T I O N Echotel Model 910 Level Switches utilize ultrasonic contact technology for measuring level in clean liquid applications. The dual conduit

More information

10 to 30 VDC (10% max. permissable ripple peak-to-peak)

10 to 30 VDC (10% max. permissable ripple peak-to-peak) R Background Suppression Sensor Photoelectric Sensor With Adjustable Setting Distance in Rugged Metal Housing H Stable detection regardless of material color or size of sensing object: 2% or less black/white

More information

Level Measurement Continuous level measurement Radar transmitters

Level Measurement Continuous level measurement Radar transmitters Overview Benefits Process Intelligence for advanced signal processing and quick and easy adjustment Self-guided quick start wizard for plug and play startup 2 GHz provides superior reflective properties

More information

WORLD-BEAM QS18AFF200 Sensors with Foreground Suppression

WORLD-BEAM QS18AFF200 Sensors with Foreground Suppression WORLD-BEAM QS8AFF00 Sensors with Foreground Suppression Datasheet Compact sensors featuring extended range and foreground suppression mode Exceptional optical performance; up to 00 mm sensing range in

More information

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22 www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview Overview Application It provides excellent results on low dielectric media. is available for standard applications and for applications that require explosion proof protection. features robust enclosure,

More information

Fisher 4200 Series Electronic Position Transmitters

Fisher 4200 Series Electronic Position Transmitters Product Bulletin D200357012 4200 Series Transmitter Fisher 4200 Series Electronic Position Transmitters Fisher 4200 Series electronic position transmitters (figure 1 and 2) combine field-proven electronic

More information

5-pole M12 connector. Connecting cable: cab-m12/5-g-2m. LED (red) for dirt accumulation indication

5-pole M12 connector. Connecting cable: cab-m12/5-g-2m. LED (red) for dirt accumulation indication D-LAS Series D-LAS-34-ED-25x2-AC-T (Glass Pane Detection) - Collimated laser beam (

More information

A-LAS Series A-LAS-F12. Design. A-LAS Series Analog Laser Light Barriers. Product name: Accessories: (cf. page 5) A-LAS-F12-(aperture)*-(fork size)**

A-LAS Series A-LAS-F12. Design. A-LAS Series Analog Laser Light Barriers. Product name: Accessories: (cf. page 5) A-LAS-F12-(aperture)*-(fork size)** A-LAS Series A-LAS-F12 - Analog signal (0...+10V) in connection with an electronic control unit type AGL3, AGL4, AGL4-HS, AGL-DIF, SI-CON11 (without PC connection) or SI-CON4, SI-CON8, SI-CON34, A-LAS-CON1

More information

Heavy-duty Metal Body Safety Interlock Switch. DIN mounting pattern for globally recognized mounting configuration

Heavy-duty Metal Body Safety Interlock Switch. DIN mounting pattern for globally recognized mounting configuration C R US Conforms to EN1088, EN292, EN60947-5-1, EN60204-1, EN50041 UL and C-UL listed T4011 Heavy-duty Metal Body Safety Interlock Switch Rugged enclosure the all metal housing and stainless steel actuator

More information

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output. GENERAL INFORMATION T6000 SERIES TRANSDUCER Electro-Pneumatic (I/P, E/P) APPLICATIONS The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional

More information

Installation Instructions PHOTOSWITCH Series 9000 On/Off and Timing Photoelectric Sensors

Installation Instructions PHOTOSWITCH Series 9000 On/Off and Timing Photoelectric Sensors Installation Instructions PHOTOSWITCH Series 9000 On/Off and Timing Photoelectric Sensors Polarized Transmitted Beam Fiber Optic All Sensors Retroreflective Retroreflective ClearSight TM Standard Diffuse

More information

General-Purpose Photoelectric Sensor

General-Purpose Photoelectric Sensor General-Purpose Photoelectric Sensor Wide Selection of High Performance Small DC Sensors Offers Longer Sensing Distances Fast 0. msec response time for high-speed sensing Extended sensing distances up

More information

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI Overview The is a -wire, 2 GHz FMCW radar level transmitter with extremely high signal-to-noise ratio and advanced signal processing for continuous monitoring of solids up to 100 m (328 ft). It is ideal

More information

Installation Instructions PHOTOSWITCH Series 9000 On/Off and Timing Photoelectric Sensors

Installation Instructions PHOTOSWITCH Series 9000 On/Off and Timing Photoelectric Sensors Installation Instructions PHOTOSWITCH Series 9000 On/Off and Timing Photoelectric Sensors All Sensors Retroreflective Polarized Retroreflective ClearSight TM Standard Diffuse Long Range Diffuse Extended

More information

Technical Instructions Document No EA GQD October 25, OpenAir GQD Series

Technical Instructions Document No EA GQD October 25, OpenAir GQD Series OpenAir GQD Series Spring Return, 20 lb-in (2 Nm), Rotary Electronic Damper Actuators Technical Instructions Document No. 155-760 EA GQD Description Features Application The OpenAir GQD Series direct-coupled

More information

Model WHD Weld Hole Detector Operator s Manual. Rev 1.1

Model WHD Weld Hole Detector Operator s Manual. Rev 1.1 Model WHD Weld Hole Detector Operator s Manual Rev 1.1 Contents 1. Introduction... 2 2. Description... 2 2.1 Model Nomenclature... 2 2.2 Operating Principle... 2 2.3 Specifications... 3 3. Location and

More information

Technical Instructions Document No EA GQD June 23, OpenAir

Technical Instructions Document No EA GQD June 23, OpenAir OpenAir Spring Return, 20 lb-in (2 Nm), Rotary GQD Series, Electronic Damper Actuators Technical Instructions Document No. 155-760 EA GQD Description Features Application The OpenAir GQD Series direct-coupled

More information

Level Lance Model 5100

Level Lance Model 5100 Sales Manual Section 100 Product Specification Model 5100 Level Lance Model 5100 GENERAL DESCRIPTION The Robertshaw Model 5100 Level-Lance is a microprocessor based, advanced technology On-Off level detection

More information

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview Overview Application It provides excellent results on low dielectric media. is available for standard applications and for applications that require explosion proof protection. features robust enclosure,

More information

The transducer component converts the measured signal and displays the actual value.

The transducer component converts the measured signal and displays the actual value. Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version

More information

Radar Level Measurement micropilot FMR 130 for stilling wells

Radar Level Measurement micropilot FMR 130 for stilling wells Technical Information TI 258F/24/ae Radar Level Measurement micropilot FMR 130 for stilling wells Smart transmitter for non-contact measurement in metallic by-pass pipes and stilling wells Suitable for

More information

T S 15KVA 1PH 240/480 Transformer

T S 15KVA 1PH 240/480 Transformer 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 T2535173S 15KVA 1PH 240/480 Transformer Acme Electric Catalog Number Manufacturer Description Weight per unit Product

More information

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks -A Load Compact: 20 x 15 x 10 mm (L x W x H). Low power consumption: 200 mw. Flux protection or plastic-sealed construction available.

More information

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35 www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up

More information

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output. GENERAL INFORMATION T6000 SERIES TRANSDUCER Electro-Pneumatic (I/P, E/P) APPLICATIONS The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional

More information

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter.   TEMPERATURE. Technology Solutions Technology Solutions TEK-TEMP 2100A Explosion-Proof Temperature Transmitter TEMPERATURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Explosion-Proof

More information

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

MODEL: M2SES SEN TRONIC AG [3] OUTPUT Super-mini Signal Conditioners Mini-M Series HIGH/LOW SELECTOR Functions & Features Monitors two DC input signals and transmits an output signal proportional to the higher or lower input CE marking UL

More information

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load Compact: 20 15 10 mm (L W H). Low power consumption: 200 mw. Flux protection or fully sealed construction available. Unique

More information

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily

More information

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

WORLD-BEAM QS18AF Sensor with Background Suppression

WORLD-BEAM QS18AF Sensor with Background Suppression WORLD-BEAM QS8AF Sensor with Background Suppression Datasheet Compact sensors featuring extended range and background suppression mode Exceptional optical performance; up to 00 mm sensing range in compact

More information

Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter

Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter Data Sheet D-FMP-10D1475W-Y_4 Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter 10D1475W/Y Flowmeter Systems utilizes a smart microprocessor converter. System accuracy of ±0.5% of

More information

Long Range Metal Body Sensor

Long Range Metal Body Sensor R Long Range Metal Body Sensor 30 m Range With Advanced Fuzzy Logic H Mutual interference protection H NPN/PNP switch selectable output H M12 plug-in connector H Meets IP67 and NEMA 4X, 6P H Vibration

More information

Field indicator for current loops with HART communication Models DIH50, DIH52

Field indicator for current loops with HART communication Models DIH50, DIH52 Accessories Field indicator for current loops with HART communication Models DIH50, DIH52 WIKA data sheet AC 80.10 for further approvals see page 6 Applications Process engineering Plant construction General

More information

21R14A Receiver 14 Control/1 Alarm/1 Safety relays 120 VAC Power Supply

21R14A Receiver 14 Control/1 Alarm/1 Safety relays 120 VAC Power Supply 21R14A Receiver 14 Control/1 Alarm/1 Safety relays Maintained Link Maintained Link. Loss of Maintained Link.. UL Rating UL 508 Environmental Rating... NEMA 4 14 control/1 alarm/1 safety relays Receive

More information

Sensing method Through-beam Retroreflective Diffuse reflective Convergent-beam Appearance Side-view Flat Side-view Flat Side-view

Sensing method Through-beam Retroreflective Diffuse reflective Convergent-beam Appearance Side-view Flat Side-view Flat Side-view R Subminiature Photoelectric Sensor Omron s Next Generation of Sub-miniature Photoelectric Sensors H Utilizes Omron s Hyper LED technology to achieve the industry s smallest visible red beam H Self-contained

More information

PICO-AMP Miniature Remote Sensing System

PICO-AMP Miniature Remote Sensing System PICO-AMP Miniature Remote Sensing System MD14 Modulated Amplifer and Ultra-small Remote Sensors PICO-AMP Features Ultra-small remote sensors to fit the tightest locations Three fixed frequency selections

More information

Type Sealing Poles Contacts Rated voltage Model 5PST-NO, SPST-NC 24 VDC *1

Type Sealing Poles Contacts Rated voltage Model 5PST-NO, SPST-NC 24 VDC *1 Slim Relays with Forcibly Guided Contacts Conforming to EN Standards EN50205 Class A, approved by VDE. Ideal for use in safety circuits in production machinery. Four-pole and six-pole Relays are available.

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters

More information

Distance-setting Photoelectric Sensor

Distance-setting Photoelectric Sensor Distance-setting Photoelectric Sensor The Combination of the Hyper LED and Shine-proof Achieves both Ease-of-use and High Performance Hyper LED mounted. Finest pin-point beam in the industry allows detection

More information

Incremental encoders Blind hollow shaft or cone shaft pulses per revolution

Incremental encoders Blind hollow shaft or cone shaft pulses per revolution Features TTL output driver for cable length up to 550 m Very high resistance to shock and vibrations Hybrid bearing for extended service life Shaft insulation up to.8 kv Large terminal box, turn by 80

More information

Single-Channel Safety Barriers Series 9001

Single-Channel Safety Barriers Series 9001 Single-Channel Safety Barriers Series 9001 > Broad product range for all standard applications in the world of automation > Flexible and space saving single and dual channel versions available > Time saving

More information

QL55 Series Luminescence Sensor

QL55 Series Luminescence Sensor Self-contained, microprocessor-based luminescence sensor Features Self-contained design in a robust, compact metal housing High sensitivity Microprocessor-controlled Senses luminescent marks, even on luminescent

More information

Echotel Model 910 Ultrasonic Level Switch

Echotel Model 910 Ultrasonic Level Switch Echotel Model 910 Ultrasonic Level Switch D E S C R I P T I O N Echotel Model 910 Level Switches utilize ultrasonic contact technology for measuring level in clean liquid applications. The dual conduit

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter ABB MEASUREMENT & ANALYTICS DATA SHEET Ultrasonic level LST400 Open channel flow transmitter 2 ULTRASONIC LEVEL LST400 / OPEN CHANNEL FLOW TRANSMITTER DS/LST400 EN REV. D Measurement made easy Reduced

More information

prosonic T FMU230, FMU231

prosonic T FMU230, FMU231 Technical Information prosonic T FMU230, FMU231 Ultrasonic Level Measurement Compact transmitters for non-contact level measurement of fluids and coarse bulk materials Application The compact transmitters

More information

1000 SERIES INSTALLATION SUPPLEMENT Rev. 7/1/10

1000 SERIES INSTALLATION SUPPLEMENT Rev. 7/1/10 1000 SERIES INSTALLATION SUPPLEMENT Rev. 7/1/10 Smartscan Incorporated 33083 Eight Mile Road Livonia, MI 48152 Phone: (248) 477-2900 Fax: (248) 477-7453 SMARTSCAN INCORPORATED Livonia, MICHIGAN 1000 The

More information

PHOTOELECTRIC S300 MAXI SENSORS APPLICATIONS.

PHOTOELECTRIC S300 MAXI SENSORS APPLICATIONS. PHOTOELECTRIC MAXI SENSORS sensors S300 The S300 series of advanced MAXI photoelectric sensors represents the most suitable solution for critical applications thanks to excellent performances and resistance

More information

Bulletin 800H Hazardous Location Push Buttons Product Overview/Specifications. Table of Contents See below.

Bulletin 800H Hazardous Location Push Buttons Product Overview/Specifications. Table of Contents See below. Bulletin H Product verview/specifications Bulletin H/ Hazardous locations push buttons and stations Classes I, II & III Divisions & / in. - NPSM barrel Type & Explosion-proof operators Table of Contents

More information

Type Sealing Poles Contacts Rated voltage Model Standard Flux-tight 4 poles 3PST-NO, SPST-NC 24 VDC G7SA-3A1B. Type LED indicator Poles Rated voltage

Type Sealing Poles Contacts Rated voltage Model Standard Flux-tight 4 poles 3PST-NO, SPST-NC 24 VDC G7SA-3A1B. Type LED indicator Poles Rated voltage Safety Relay Slim Safety Relays Conforming to EN Standards The forcibly guided contact in the assures safe operation (EN50205 Class A, approved by VDE.) Ideal for use in safety circuits in press machinery,

More information

NA DigiParts GmbH. Small / Slim Object Detection Area Sensor

NA DigiParts GmbH. Small / Slim Object Detection Area Sensor 953 PHOTO PHOTO MEASURE ITY Object Area Sensor General terms and conditions... F-7 Related Information Glossary of terms... P.1455~ Cross-beam scanning system to detect slim objects Letters or business

More information

Baymaster HL LED Luminaire High Bay for Hazardous Locations

Baymaster HL LED Luminaire High Bay for Hazardous Locations Class I, Division, Group A, B, C, D Class I, Zone, Group IIC Class II, Division &, Group E, F, G Zone and Group IIIC Zone Group IIIB Applications Enclosed and gasketed fixtures suitable for use in: A wide

More information

1000 SERIES INSTALLATION SUPPLEMENT Rev

1000 SERIES INSTALLATION SUPPLEMENT Rev 1000 SERIES INSTALLATION SUPPLEMENT Rev. 1-1-12 Smartscan Incorporated 33083 Eight Mile Road Livonia, MI 48152 Phone: (248) 477-2900 Fax: (248) 477-7453 SMARTSCAN INCORPORATED Livonia, MICHIGAN 1000 The

More information

PROXIMITY SENSOR TERMINOLOGY

PROXIMITY SENSOR TERMINOLOGY Never use this desk reference for installation or operation of equipment. Refer to manual for installation and operation instructions. The following descriptions refer to the European standard EN 60947-5-2.

More information

Long Range Metal Body Sensor

Long Range Metal Body Sensor R Long Range Metal Body Sensor 30 m Range With Advanced Fuzzy Logic H Mutual interference protection H NPN/PNP switch selectable output H M12 plug-in connector H Meets IP67 and NEMA 4X, 6P H Vibration

More information

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview Overview Design The transmitter is available in different enclosure to fit any demands: IP67 enclosure for compact or wall mounting IP00 as a 19 insert IP65 for wall mounting IP65 enclosure in stainless

More information

onlinecomponents.com

onlinecomponents.com Key features: Relay Barrier: Intrinsically Safe Explosion-Proof: EB3C Relay [Exia] II C IEC0079 compliant Dry-contact switches can be connected to the EB3C 8- and 1-circuit types are available in common

More information

Distance-setting Photoelectric Sensor

Distance-setting Photoelectric Sensor Distance-setting Photoelectric Sensor The Combination of the Hyper LED and Shine-proof Achieves both Ease-of-use andhighperformance Hyper LED mounted. Finest pin-point beam in the industry allows detection

More information

Model OB-ITF Infrared Through-Beam Fiber Optic Optical Barrier Operator s Manual. Version

Model OB-ITF Infrared Through-Beam Fiber Optic Optical Barrier Operator s Manual. Version Model OB-ITF Infrared Through-Beam Fiber Optic Optical Barrier Operator s Manual Version 11-2010 Contents 1. Introduction... 2 2. Description... 2 2.1 Model Nomenclature... 2 2.2 Operating Principle...

More information

Temperature transmitter itemp RTD DIN rail TMT 127

Temperature transmitter itemp RTD DIN rail TMT 127 Technical information TI 095R/24/ae Nr. 510 06165 Temperature transmitter itemp RTD DIN rail TMT 127 Pt100 transmitter for an economical, high accuracy temperature monitoring. Fixed range measurement,

More information

LA-T SERIES. Fast and reliable minute granular flaw detection in winding wires. Winding Wire Granular Flaw Detector PARTICULAR USE SENSORS

LA-T SERIES. Fast and reliable minute granular flaw detection in winding wires. Winding Wire Granular Flaw Detector PARTICULAR USE SENSORS SERIES Winding Wire Granular Flaw Detector Orders accepted till September, 2003 Production to be discontinued from April, 2004 Fast and reliable minute granular flaw detection in winding wires Slim Reliable

More information

NA1-11. Small / Slim Object Detection Area Sensor. Cross-beam scanning system to detect slim objects. Letters or business cards detectable!

NA1-11. Small / Slim Object Detection Area Sensor. Cross-beam scanning system to detect slim objects. Letters or business cards detectable! 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

MODEL: M2DYS SEN TRONIC AG

MODEL: M2DYS SEN TRONIC AG Super-mini Signal Conditioners Mini-M Series CURRENT LOOP SUPPLY Functions & Features Powers a 20 ma DC current loop Short circuit protection Applicable to smart transmitters CE marking UL approval Typical

More information

MLV12 Series Dura-Vue TM Sensors

MLV12 Series Dura-Vue TM Sensors MLV Series Dura-Vue TM Sensors Diffuse Mode with Background Evaluation See page 5 Reliable detection of all surfaces regardless of color or shape Cross-talk immunity Sensing Range: 5 mm Output: -in- Retro-Reflective

More information

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/ > 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

Digital conductivity transmitter

Digital conductivity transmitter Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due

More information

Digital Input Output Module for Zone 1 Series 9470/32

Digital Input Output Module for Zone 1 Series 9470/32 www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used

More information

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series MODEL: WDYS Space-saving Dual Output Signal Conditioners Mini-MW Series CURRENT LOOP SUPPLY Functions & Features Powers a 0 ma DC current loop Short circuit protection Applicable to smart transmitters

More information

E3S-BT11 E3S-BR11 E3S-BD11

E3S-BT11 E3S-BR11 E3S-BD11 General Purpose Photoelectric Sensor Miniature DC Sensor with Built-in Amplifier Offers Vertical or Horizontal Single-Screw Mounting H Visible red beam H High-speed sensing, 0.5 ms response time H NEMA

More information

Fuzzy Temperature Controllers E5AF

Fuzzy Temperature Controllers E5AF Fuzzy Temperature Controllers 1/4 DIN Controller Combines Fuzzy and PID Control For Fast Response to Process Disturbances Advanced PID control provides optimal response during start-up and steadystate

More information

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33 www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used

More information

MY-GS. Miniature Power Relays. Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays.

MY-GS. Miniature Power Relays. Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays. Miniature Power Relays CSM DS_E_1_1 Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays Relays with AC and DC coils have different colors of operating indicators

More information

Baymaster LED Luminaire High Bay for Hazardous Locations

Baymaster LED Luminaire High Bay for Hazardous Locations Class I, Division, Group A, B, C, D Class I, Zone, Group IIC Class II, Division &, Group E, F, G Zone and Group IIIC Zone Group IIIB Applications Enclosed and gasketed fixtures suitable for use in: A wide

More information

Field indicator for current loops with HART communication Models DIH50, DIH52

Field indicator for current loops with HART communication Models DIH50, DIH52 Accessories Field indicator for current loops with HART communication Models DIH50, DIH52 WIKA data sheet AC 80.10 for further approvals see page 7 Applications Process engineering Plant construction General

More information

LST400 Ultrasonic level / open channel flow transmitter

LST400 Ultrasonic level / open channel flow transmitter Data sheet DS/LST400 EN Rev.C LST400 Ultrasonic level / open channel flow transmitter Measurement made easy Reduced installation cost Easy access terminations Integrated echo display makes for easy troubleshooting

More information

Built-in Amplifier Photoelectric Sensor

Built-in Amplifier Photoelectric Sensor Built-in Amplifier Photoelectric Sensor Easy-to-use, Low-cost Photoelectric Sensor Incorporating s that can be clearly seen from a distance Conforms to EN and IEC standards Incorporating polarizing function,

More information