In Icu = Ics Icw Envelope Standard 100% Rated

Size: px
Start display at page:

Download "In Icu = Ics Icw Envelope Standard 100% Rated"

Transcription

1 ntelliguard G Step 1 Step 2 Step 3 How to order Step 4 hoose urrent rating hoose required Interruption Rating efine if a reaker or Isolator is needed Proceed to establish the first 5 digits of the atalogue Number as indicated here Select the required product - reaker or Isolator In ixed Pattern - reaker or Isolator s raw out, Moving Portion - assette for raw out reaker or Isolator Order codes } } } In Icu = Ics Icw nvelope Standard 100% Rated 440V reaker Isolator (1) reaker Isolator (1) k 50k 1 GG04S GJ04S 65k 65k 1 GG04N GW04N 85k 65k 1 GG04H 85k 85k 2 GG04 GW04M 100k 85k 2 GG04M k 50k 1 GG07S GJ07S 65k 65k 1 GG07N GW07N 85k 65k 1 GG07H 85k 85k 2 GG07 GW07M 100k 85k 2 GG07M k 50k 1 GG08S GJ08S 65k 65k 1 GG08N GW08N 85k 65k 1 GG08H 85k 85k 2 GG08 GW08M 100k 85k 2 GG08M k 50k 1 GG10S GJ10S 65k 65k 1 GG10N GW10N 85k 65k 1 GG10H 85k 85k 2 GG10 GW10M 100k 85k 2 GG10M k 50k 1 GG13S GJ13S 65k 65k 1 GG13N GW13N 85k 65k 1 GG13H 85k 85k 2 GG13 GW13M 100k 85k 2 GG13M k 50k 1 GG16S GJ16S 65k 65k 1 GG16N GW16N 85k 65k 1 GG16H 85k 85k 2 GG16 GJ16M 100k 85k 2 GG16M k 50k 1 GG20S GJ20S 65k 65k 1 GG20N GW20N 85k 65k 1 GG20H 85k 85k 2 GG20 GW20M 100k 85k 2 GG20M k 65k 2 GG25N GJ25N 85k 85k 2 GG25H GW25H 100k 85k 2 GG25M k 65k 2 GG32N GJ32N GH32N GK32N 85k 85k 2 GG32H GW32M GH32H GZ32H 100k 85k 2 GG32M GH32M 100k 100k 3 GG32G GJ32L 150k 100k 3 GG32L k 65k 2 GG40N GJ40N GH40N GK40N 85k 85k 2 GG40H GW40M GH40H GZ40H 100k 85k 2 GG40M GH40M 100k 100k 3 GG40G GJ40L 150k 100k 3 GG40L k 100k 3 GG50M GJ50L 150k 100k 3 GG50L k 100k 3 GG64M GJ64L 150k 100k 3 GG64L (1) On Isolators Icu and Ics values do not apply efines the 6th digit In catalogue number 4 = reaker / Isolator In ixed Pattern 3 pole 6 = reaker / Isolator In ixed Pattern 4 pole (1) 1 = reaker / Isolator Moving Portion Only 3 pole 3 = reaker / Isolator Moving Portion Only 4 pole (2) 2 = assette for raw out Pattern = ixed Portion Only 3 pole 5 = assette for raw out Pattern = ixed Portion Only 4 pole (3) (2) 4 pole Neutral Left xamples reaker 4p raw-out Portion only- Icu=85k, Ics=Icw=65k: GG16H3 reaker 3p 3200 ixed Pattern -Horizontal Rear onnections - Icu=Ics=Icw=65k: GG32N4.2

2 ntelliguard G in 8 steps Step 5 Step 6 Step 7 Step 8 inalize the basic atalogue number see catalogue pages: ixed Pattern raw out Portion.6 - onnections fixed pattern.11 - assettes, draw out completing the basic catalogue number No addition Indicates reaker / Isolator In ixed Pattern has set of 3NO/3N aux. ontacts included reaker in fixed Pattern re equipped with Rear onnection (Horizontal) Other options include Rear (Vertical) and ront (lat) See page 6 to order ield mountable daptation Kits See pages.4, 5 & 6 No addition Indicates reaker / Isolator Moving Portion Only has set of 3NO/3N aux. ontacts included See pages.7, 8 & 9 U = assette with Universal 'T stabs' suited for use as Horizontal or Vertical rear connections Safety Shutters Supplied with assette (3) V = assette with Vertical Rear onnections Safety Shutters Supplied with assette (3) = assette with ront lat connections Safety Shutters Supplied with assette (3) See page.11 asic atalogue number is a Manually operated device If a Motor Operated device is requested? Please order Motor and closing coils as Indicated here (3) dd atalogue number (s) If chosen device is a reaker or Isolator nvelope 1 See page.17 Order a Motor Type1 and 1 losing oil or 1 ommand closing coil ased on voltage Requirements and specifications If chosen device is a reaker or Isolator nvelope 2 or 3 See page.17 Order a Motor type 2 and 1 losing oil or 1 ommand closing coil ased on voltage Requirements and specifications If Universal internal ccessories (3) are needed? Options UVR or SHT release (s) Network Interlocks uxiliary contacts larm & signal contacts dd atalogue number (s) If chosen device is a reaker or Isolator See page.17 To add up to 3 SHT or UVR Releases Or 1 Network Interlock oils and 1 SHT or UVR Release If chosen device is a reaker or Isolator See page.17 To extend on the installed 3 NO + 3N contacts Maximum of 8 possible If chosen device is a reaker or Isolator See page.17 To add ell larm and/or oils signalling contacts If chosen device is a assette See page.17 &.18 To dd Position indication ontacts in assette Or provisions for key interlocks ull atalogue number defines: reaker without Trip Unit or all reakers Trip Unit dd atalogue number (s) If chosen device is a reaker See pages.12 to.16 hoose and dd a Trip Unit out of the the four basic types and 39 different options. Offering n xtremely Large setting range covering Overload, elayed and Instantaneous Short-circuit Protection Groundfault Protection in Single or ual mode suited for applications as U, R & S or combinations thereof omplete and sophisticated Network measurement options, Including Wave orm apture Multiple relaying options as Zone Selective Interlock, Undervoltage, Overvoltage, Reverse Power etc. - Or - 2nd ordering method can be used in which the fully configured breaker or cassette is defined in one character string. This string comprises 19 digits when used for the breaker and 12 for when used for the cassette. This global ordering code is referred to within G as the: atalogue Number It is used on all relevant ordering documents and printed on each ntelliguard G breaker front facia. n explanation of this code and its use can be found on page.30 of this catalogue. When ordering with the method indicated here our R department will define and confirm the mentioned individual atalogue Number. How to order in 8 steps (3) evices ordered here are supplied factory fitted Remark: or ield Mountable ccessories see page.21 to.25.3

3 ntelliguard G asic breakers executed in a fixed mounting pattern - With Horizontal Rear onnection (or other options, please refer to page.6) (1) - With ux.contact block equipped with 3 NO and 3 N contacts - asic reaker MUST be equipped with a Trip Unit (or options, please refer to page.12 to.16) - or 1000V applications (M and L types) phase seperators are required (see page.23) ixed Mounting Pattern 3 pole 4 pole (2) Order codes S type Icu = Ics = Icw 50k N type Icu = Ics = lcw 65k H type Icu = Ics = 85k lcw = 65k Rating () at. No. Ref. No. at. No. Ref. No. 400 GG04S GG04S GG07S GG07S GG08S GG08S GG10S GG10S GG13S GG13S GG16S GG16S GG20S GG20S GG04N GG04N GG07N GG07N GG08N GG08N GG10N GG10N GG13N GG13N GG16N GG16N GG20N GG20N GG25N GG25N GG32N GG32N GG40N GG40N GG04H GG04H GG07H GG07H GG08H GG08H GG10H GG10H GG13H GG13H GG16H GG16H GG20H GG20H H type Icu = Ics = Icw 85k M type Icu = Ics = 100k Icw = 85k G-M type Icu = Ics = Icw 100k 400 GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG25H GG25H GG32H GG32H (1) GG40H GG40H GG04M GG04M GG07M GG07M GG08M GG08M GG10M GG10M GG13M GG13M GG16M GG16M GG20M GG20M GG25M GG25M GG32M GG32M (1) GG40M GG40M GG32G GG32G GG40G GG40G GG50M GG50M GG64M GG64M L type Icu = Ics = 150k Icw = 100k 3200 GG32L GG32L GG40L GG40L GG50L GG50L GG64L GG64L (1) Rear Vertical onnection for Indicated 4000 types (2) 4th pole on Left, Trip Unit ield onfigurable at 0, 50 or 100% of phase rating.4

4 Isolators or Non utomatic reakers executed in a fixed mounting pattern ntelliguard G - With Horizontal Rear onnection (or other options, please refer to page.6) (1) - With ux. contact block equipped with 3 NO and 3 N contacts - or 1000V applications (M and L types) phase seperators are required (see page.23) ixed Mounting Pattern S type Non utomatic Icw 50k N type Non utomatic Icw 65k M type Non utomatic Icw 85k L type Non utomatic Icw 100k (1) Rear Vertical onnection for Indicated 4000 types (2) 4th pole on Left 3 pole 4 pole (2) Rating () at. No. Ref. No. at. No. Ref. No. 400 GJ04S GJ04S GJ07S GJ07S GJ08S GJ08S GJ10S GJ10S GJ13S GJ13S GJ16S GJ16S GJ20S GJ20S GW04N GW04N GW07N GW07N GW08N GW08N GW10N GW10N GW13N GW13N GW16N GW16N GW20N GW20N GJ25N GJ25N GJ32N GJ32N (1) GJ40N GJ40N GW04M GW04M GW07M GW07M GW08M GW08M GW10M GW10M GW13M GW13M GW16M GW16M GW20M GW20M GW25M GW25M GW32M GW32M (1) GW40M GW40M GJ32L GJ32L GJ40L GJ40L GJ50L GJ50L GJ64L GJ64L ixed Mounting Pattern.5

5 ntelliguard G Termination sets for reakers & Isolators in ixed pattern - To modify Standard connection (Horizontal Rear) to: - Vertical Rear - ront flat connection - Sets containing terminals and hardware for the line & load side of the breaker Order codes Vertical Rear onnections Termination sets for reakers & Isolators in fixed Pattern Suited for use with ntelliguard G types 3 pole 4 pole Rating () at. No. Ref. No. at. No. Ref. No. Terminations for envelope GG, GJ & GW type S, N & H G20H4RVI G20H6RVI Terminations for envelope GG, GJ & GW type, N, H & M G32M4RVI G32M6RVI (2) GG, GJ & GW type N, H & M G40M4RVI G40M6RVI Terminations for envelope GG & GJ type G, M & L G64L4RVI G64L6RVI ront access onnections Terminations for envelope GG, GJ & GW type S, N & H G16H4I G16H6I GG, GJ & GW type S, N & H G20H4I G20H6I Terminations for envelope GG, GJ & GW type, N, H & M G32M4I G32M6I GG, GJ & GW type N, H & M G40M4I G40M6I Wall mounting rackets (1) Wall Mounting rackets for nv. 1 & 2 GMTG GMTG (1) Recommended for use with ront access onnections (2) or the 4000 types are supplied with the standard fixed breaker.6

6 ntelliguard G Notes Terminations; ixed Pattern.7

7 ntelliguard G asic breakers: raw out reakers; Moving Portion only - With ux. contact block equipped with 3 NO and 3 N contacts - asic reaker MUST be equipped with a Trip Unit (please refer to page.12 to.16 for options) - cassette is needed, please refer to page.11 for options - or 1000V applications (M and L types) phase seperators are required (see page.23) raw out Pattern; moving portion only 3 pole 4 pole (1) Order codes S type Icu = Ics = Icw 50k N type Icu = Ics = Icw 65k H type Icu = Ics = 85k Icw = 65k Rating () at. No. Ref. No. at. No. Ref. No. 400 GG04S GG04S GG07S GG07S GG08S GG08S GG10S GG10S GG13S GG13S GG16S GG16S GG20S GG20S GG04N GG04N GG07N GG07N GG08N GG08N GG10N GG10N GG13N GG13N GG16N GG16N GG20N GG20N GG25N GG25N GG32N GG32N GG40N GG40N GG04H GG04H GG07H GG07H GG08H GG08H GG10H GG10H GG13H GG13H GG16H GG16H GG20H GG20H H type Icu = Ics = Icw 85k M type Icu = Ics = 100k Icw = 85k G-M type Icu = Ics = Icw 100k 400 GG GG GG GG GG GG GG GG GG GG GG GG GG GG GG25H GG25H GG32H GG32H GG40H GG40H GG04M GG04M GG07M GG07M GG08M GG08M GG10M GG10M GG13M GG13M GG16M GG16M GG20M GG20M GG25M GG25M GG32M GGM3M GG40M GG40M GG32G GG32G GG40G GG40G GG50M GG50M GG64M GG64M L type Icu = Ics = 150k Icw = 100k 3200 GG32L GG32L GG40L GG40L GG50L GG50L GG64L GG64L (1) 4th pole on Left, Trip Unit ield onfigurable at 0, 50 or 100% of phase rating.8

8 ntelliguard G raw out reakers with vertical dual clusters; Moving Portion only - raw out reaker with no or very limited de-rating when used enclosed - With ux. contact block equipped with 3 NO and 3 N contacts - asic reaker MUST be equipped with a Trip Unit (please refer to page.12 to.16 for options) - cassette with vertical clusters is needed, please refer to page.11 for options raw out Pattern, vertical clusters; moving portion only N type Icu = Ics = Icw 65k H type Icu = Ics = Icw 85k M type Icu = Ics = 100k Icw = 85k 3 pole 4 pole (1) Rating () at. No. Ref. No. at. No. Ref. No GH32N GH32N GH40N GH40N GH32H GH32H GH40H GH40H GH32M GH32M GH40M GH40M raw out Pattern; moving portion (1) 4th pole on Left, Trip Unit onfigurable at 0, 50 or 100% of phase rating.9

9 ntelliguard G Isolators or Non utomatic reakers: raw out Patterns; Moving Portion only - With ux. contact block equipped with 3 NO and 3 N contacts - cassette is needed, please refer to page.11 for options - or 1000V applications (M and L types) phase seperators are required (see page.23) raw out Pattern; moving portion only 3 pole 4 pole (1) Order codes S type Non utomatic Icw 50k N type Non utomatic Icw 65k M type Non utomatic Icw 85k L type Non utomatic Icw 100k Rating () at. No. Ref. No. at. No. Ref. No. 400 GJ04S GJ04S GJ07S GJ07S GJ08S GJ08S GJ10S GJ10S GJ13S GJ13S GJ16S GJ16S GJ20S GJ20S GW04N GW04N GW07N GW07N GW08N GW08N GW10N GW10N GW13N GW13N GW16N GW16N GW20N GW20N GJ25N GJ25N GJ32N GJ32N GJ40N GJ40N GW04M GW04M GW07M GW07M GW08M GW08M GW10M GW10M GW13M GW13M GW16M GW16M GW20M GW20M GW25M GW25M GW32M GW32M GW40M GW40M GJ32L GJ32L GJ40L GJ40L GJ50L GJ50L GJ64L GJ64L Power ircuit reakers types with Vertical luster system Isolators or Non utomatic reakers with dual vertical clusters; Moving Portion only - raw out Patterns with no or very limited de-rating when used enclosed - With ux. contact block equipped with 3 NO and 3 N contacts - cassette with vertical clusters is needed, please refer to page.11 for options raw out Pattern, vertical clusters; moving portion only N type Non utomatic Icw 65k H type Non utomatic Icw 85k 3 pole 4 pole (1) Rating () at. No. Ref. No. at. No. Ref. No GK32N GK32N GK40N GK40N GZ32H GZ32H GZ40H GZ40H (1) 4th pole on Left.10

10 Universal Rear onnections Vertical rear onnections assettes for use with reakers & Isolators in raw out Pattern; actory mounted ntelliguard G - References apply for assettes supplied in one Packaging with reakers or Isolators (or Separate assettes see page.25) - With onnection modes as indicated in left column - ach cassette is supplied with safety shutters assettes for raw out Pattern; fixed portion only 3 pole 4 pole Rating () Suited for use with ntelliguard G -G types at. No. Ref. No. at. No. Ref. No. assette for envelope GG, GJ & GW type S, N & H GG13H2UM GG13H5UM GG, GJ & GW type S, N & H GG16H2UM GG16H5UM GG, GJ & GW type S, N & H GG20H2UM GG20H5UM assette for envelope GG, GJ & GW type N, & M GG20M2UM GG20M5UM GG, GJ & GW type N, H & M GG25M2UM GG25M5UM GG, GJ & GW type N, H & M (1) GG32M2UM GG32M5UM GG, GJ & GW type N, H & M (1) GG40M2UM GG40M5UM Remark: ach cassette is supplied with connection pads that can be rotated and used for Vertical or Horizontal connections. assette for envelope 3 (2) (3) GG & GJ type G, M & L GG64L2UM GG64L5UM assette with dual vertical clusters and connection pads for limited de-rating envelope GH, GK, GJ & GZ type N.H & M GH32M2VM GH32M5VM GH, GK, GJ & GZ type N.H & M (1) GH40M2VM GH40M5VM raw out Pattern: cassettes ront access onnections assette for envelope GG, GJ & GW type S, N & H GG13H2M GG13H5M GG, GJ & GW type S, N & H GG16H2M GG16H5M GG, GJ & GW type S, N & H GG20H2M GG20H5M assette for envelope GG, GJ & GW type, N, H & M GG20M2M GG20M5M GG, GJ & GW type N, H & M GG25M2M GG25M5M GG, GJ & GW type N, H & M GG32M2M GG32M5M GG, GJ & GW type N, H & M GG40M2M GG40M5M (1) assettes for envelope 2 are limited to a current of 3200 when connected in horizontal mode. onnected in vertical mode a 4000 rating is achieved (2) The assette for envelope 3 is limited to a current of 5000 when connected in horizontal mode onnected in vertical mode it has a rating of This cassette type is NOT depicted here (3) 4th pole on Left.11

11 ntelliguard G Trip Units - actory mounted GT- LT- asic functionality esignation xtended functionality at. No. Ref. No. LT GT- Trip Unit with: None GTG00K1-S LT- 0,2-1 x In = Ir LT ST I²T ON or O ST GT-Rating Plug Required for all types GTPUNI ST I t on 2 ST Order codes LT- G LT ST ST GT- Trip Unit with: None GTG00K2-S LT- 0,2-1 x In = Ir LT ST I²T ON or O ST G I²T ON or O G GT-Rating Plug Required for all types GTPUNI G GT- S LT- LT GT-S Trip Unit with: None GTG00K9-S LT- 0,2-1 x In = Ir LT ST I²T ON or O ST I ST ST I GT-Rating Plug Required for all types GTPUNI LT- G LT ST ST I GT-S Trip Unit with: None GTG00K3-S LT- 0,2-1 x In = Ir LT + Modbus ommunication GTG00K3-2S ST I²T ON or O ST G I²T ON or O G I GT-Rating Plug Required for all types GTPUNI LT- G G LT ST ST l ext. GT-S Trip Unit with: None GTG00K4-S LT- 0,2-1 x In = Ir LT + Modbus ommunication GTG00K4-2S ST I²T ON or O ST G I²T ON or O G I ext. GT-Rating Plug Required for all types GTPUNI G.12

12 ntelliguard G Trip Units - actory mounted GT- N LT- asic functionality esignation xtended functionality at. No. Ref. No. LT xtended functionality RLT ST ST I GT-N Trip Unit with: Measurement unit (1) GTG00K9-4S LT- 0,2-1 x In = Ir RLT Instantaneous LT ST I²T ON or O ST I RLT GT-Rating Plug Required for all types GTPUNI lectronic Trip Units LT- G asic functionality LT ST G I 2 t on ST xtended functionality I GT-N Trip Unit with: Measurement unit (1) GTG00K3-4S LT- 0,2-1 x In = Ir RLT Instantaneous LT ST I²T ON or O + Modbus ommunication GTG00K3T6S ST G I²T ON or O G I RLT + Zone Selective Interlock on I, ST & G functions GT-Rating Plug Required for all types GTPUNI RLT LT- G asic functionality GT-N Trip Unit with: Measurement unit (1) GTG00K4-4S LT- 0,2-1 x In = Ir RLT Instantaneous LT + Modbus ommunication GTG00K4T6S LT ST I²T ON or O ST G I²T ON or O G I ext. RLT + Zone Selective Interlock on I ext., ST & G functions ST asic functionality I 2 t ST GT-Rating Plug Required for all types GTPUNI G I ext. xtended functionality xtended functionality RLT (1) n auxiliary Power onditioner is obligatory when a fully functioning measurement is required see page.22.13

13 ntelliguard G Trip Units - actory mounted Order codes GT- H LT- LT- asic functionality esignation xtended functionality at. No. Ref. No. LT ST xtended functionality LT I 2 t on ST I GT-H Trip Unit with: LT and shape hoice (LT or LT) GTG00N9-5S LT- 0,2-1 x In =Ir Measurement Unit (1) -OR- ata aquisition & Relay functionality LT- 0,2-1 x in =Ir RLT Instantaneous LT ST I 2 T ON or O LT and shape hoice (LT or LT) GTG00N9-8S ST Measurement Unit (1) I ata aquisition & Relay functionality RLT RLT Instantaneous Modbus ommunication LT and shape hoice (LT or LT) GTG00N9-9S Measurement Unit (1) ata aquisition & Relay functionality RLT Instantaneous Profibus ommunication GT-Rating Plug Required for all types GTPUNI RLT i LT- G LT- asic functionality LT ST I 2 t on xtended functionality LT G RLT i ST I GT-H Trip Unit with: LT and shape hoice (LT or LT) GTG00N5-5S LT- 0,2-1 x In =Ir ual G Protection (Res./Sum or T) -OR- Measurement Unit (1) LT- 0,2-1 x in =Ir ata aquisition & Relay functionality LT RLT Instantaneous ST I 2 T ON or O ST LT and shape hoice (LT or LT) GTG00N5-8S G sum. I 2 T ON or O ual G Protection (Res./Sum or T) -N/OR- Measurement Unit (1) G T I 2 T ON or O (2) ata aquisition & Relay functionality G RLT Instantaneous I Modbus ommunication RLT LT and shape hoice (LT or LT) GTG00N5-9S ual G Protection (Res./Sum or T) Measurement Unit (1) ata aquisition & Relay functionality RLT Instantaneous Profibus ommunication LT and shape hoice (LT or LT) GTG00N5T5S ual G Protection (Res./Sum or T) Zone Selective Interlock on ST, I & G Measurement Unit (1) ata aquisition & Relay functionality RLT Instantaneous LT and shape hoice (LT or LT) GTG00N5T8S ual G Protection (Res./Sum or T) Zone Selective Interlock on ST, I & G Measurement Unit (1) ata aquisition & Relay functionality RLT Instantaneous Modbus ommunication LT and shape hoice (LT or LT) GTG00N5T9S ual G Protection (Res./Sum or T) Zone Selective Interlock on ST, I & G Measurement Unit (1) ata aquisition & Relay functionality RLT Instantaneous Profibus ommunication GT-Rating Plug Required for all types GTPUNI (1) n auxiliary Power onditioner is obligatory when a fully functioning measurement is required see page.22 (2) The use of an interposing current transformer is required. (supplied, mounted in device).14

14 ntelliguard G Trip Units - actory mounted GT- H LT- G LT- asic functionality esignation xtended functionality at. No. Ref. No. LT ST xtended functionality LT G ST RLT i (1) n auxiliary Power onditioner is obligatory when a fully functioning measurement is required see page.22 (2) The use of an interposing current transformer is required. (supplied, mounted in device) l ext. GT-H Trip Unit with: LT and shape hoice (LT or LT) GTG00N7-5S LT- 0,2-1 x In =Ir ual G Protection (Res./Sum or T) -OR- Measurement Unit (1) LT- 0,2-1 x In =Ir ata aquisition & Relay functionality LT RLT Instantaneous ST I 2 T ON or O ST LT and shape hoice (LT or LT) GTG00N7-8S G sum. I 2 T ON or O (2) ual G Protection (Res./Sum or T) -N/OR- Measurement Unit (1) G T I 2 T ON or O ata aquisition & Relay functionality G RLT Instantaneous I ext. Modbus ommunication RLT LT and shape hoice (LT or LT) GTG00N7-9S ual G Protection (Res./Sum or T) Measurement Unit (1) ata aquisition & Relay functionality RLT Instantaneous Profibus ommunication LT and shape hoice (LT or LT) GTG00N7T5S ual G Protection (Res./Sum or T) Zone Selective Interlock on ST, I & G ST & G Measurement Unit (1) ata aquisition & Relay functionality RLT Instantaneous LT and shape hoice (LT or LT) GTG00N7T8S ual G Protection (Res./Sum or T) Zone Selective Interlock on ST, I & G ST & G Measurement Unit (1) ata aquisition & Relay functionality RLT Instantaneous Modbus ommunication LT and shape hoice (LT or LT) GTG00N7T9S ual G Protection (Res./Sum or T) Zone Selective Interlock on ST, I & G ST & G Measurement Unit (1) ata aquisition & Relay functionality RLT Instantaneous Profibus ommunication GT-Rating Plug Required for all types GTPUNI lectronic Trip Units.15

15 ntelliguard G Trip Units - actory mounted Order codes GT- H LT- G LT- asic functionality esignation xtended functionality at. No. Ref. No. LT ST xtended functionality LT G ST RLT i l ext. GT-H Trip Unit with: LT and shape hoice (LT or LT) GTG00N6-5S LT- 0,2-1 x In =Ir ual G Protection (Res./Sum or T) -OR- Measurement Unit (1) LT- 0,2-1 x In =Ir ata aquisition & Relay functionality LT RLT Instantaneous ST I 2 T ON or O With standard Instaneous ST Idem with xtended Instananeous GTG00N8-5S G (2) sum. I 2 T ON or O -N/OR- LT and shape hoice (LT or LT) GTG00N6-8S G (2) T I 2 N ON or O (3) ual G Protection (Res./Sum or T) G Measurement Unit (1) I or I ext. ata aquisition & Relay functionality RLT RLT Instantaneous Modbus ommunication With standard Instaneous Idem with xtended Instananeous GTG00N8-8S LT and shape hoice (LT or LT) GTG00N6-9S ual G Protection (Res./Sum or T) Measurement Unit (1) ata aquisition & Relay functionality RLT Instantaneous Profibus ommunication With standard Instaneous Idem with xtended Instananeous GTG00N8-9S LT and shape hoice (LT or LT) GTG00N6T5S ual G Protection (Res./Sum or T) Zone Selective Interlock on ST, I & G Measurement Unit (1) ata aquisition & Relay functionality RLT Instantaneous With standard Instaneous Idem with xtended Instananeous GTG00N8T5S LT and shape hoice (LT or LT) GTG00N6T8S ual G Protection (Res./Sum or T) Zone Selective Interlock on ST, I & G Measurement Unit (1) ata aquisition & Relay functionality RLT Instantaneous Modbus ommunication With standard Instaneous Idem with xtended Instananeous GTG00N8T8S (1) n auxiliary Power onditioner is obligatory when a fully functioning measurement is required see page.22 (2) oes NOT trip the associated ntelliguard G reaker, UT produces an larm signal (3) The use of an interposing current transformer is required. (supplied, mounted in device) LT and shape hoice (LT or LT) GTG00N6T9S ual G Protection (Res./Sum or T) Zone Selective Interlock on ST, I & G Measurement Unit (1) ata aquisition & Relay functionality RLT Instantaneous Profibus ommunication With standard Instaneous Idem with xtended Instananeous GTG00N8T9S GT-Rating Plug Required for all types GTPUNI

16 ntelliguard G Internal ccessories - actory mounted or field mounted variants see page.20 &.21 Motor Operators and losing oils (4) Motor Operator Type 1 Motor Operator Type 2 & 3 Releases uxiliary ontacts at. No. Ref. No. at. No. Ref. No. at. No. Ref. No V GM GM V GM GM V GM GM V GM GM V GM GM V GM GM V GM GM V GM GM V GM GM V GM GM losing oil omm. losing oil (1) 2V GN G V - GN G V GN G V - GN G V - GN G V ; 250V GN G V GN G V GN G Undervoltage Shunt Network Interlock 24V GUVT GSTR V - GUVT GSTR V GUVT GSTR V - GUVT GSTR GNTK V - GUVT GSTR GNTK V ; 250V GUVT GSTR V GUVT GSTR V GUVT GSTR Power Rated 3NO & 3N elivered as standard option in all ntelliguard G breakers & Isolators (3) Power Rated 8NO & 8N GS Power Rated 3NO & 3N GS signal rated 2NO & 2N Power Rated 4NO & 4N + signal rated 4NO & 4N GS Internal ccessories; actory mounted ell larm ontacts 1 hangeover GT Indication ontacts //UVT/STR Release indicator 1NO reaker Ready to lose indic. (2) 1NO Power rated wired through sec. iscon. Signal rated wired through sec. iscon. Signal rated wired Trip Unit (comm.) GSP GSP GRT GRT GRT Position Indication ontacts assette Power rated on assette 1 hangeover per position GPS hangeovers per position GPS (1) esigned to be accessed through the Trip Unit communication option (Modbus or Profibus). Up to a voltage rating of 277V a extra coil operating/on push button is mounted on the reaker front facia. (2) Not available as field mountable accessory (3) evice code GS (4) Motor Spring charged indication contact supplied with Motor Operator.17

17 ntelliguard G Internal ccessories - actory mounted or field mounted variants see page.20 &.21 Locking Mechanisms (1) Ronis astell Profalux Mounted on reaker The Ronis and Profalux devices allow 1 to 4 Locks to be placed. The astell device 1 Mounted on assette. (2 devices for 2 locks are possible) at. No. Ref. No. at. No. Ref. No. at. No. Ref. No. GRON GS GPRO GRON GPRO Order codes Operation ront ascia of reaker ounter; number of Operations GMN Pre-assembled interlocks for cables (2) Interlock Scheme ixed Pattern raw out Type rk. 1 rk. 2 rk. 3 at. No. Ref. No. at. No. Ref. No. O O or ach reaker or ach reaker ON O GI GI2W O ON O O O or ach reaker or ach reaker ON O O GI GI3W O ON O O O ON O O O ON O O O O ON or ach reaker or ach reaker O ON O GI GI3W ON ON O O ON ON ON O ON O O O or rk.1 & 3 or rk.1 & 3 ON O O GI GI2W O O ON ON O ON or rk. 2 or rk. 2 O ON O GI3T GI3WT (1) or the separately available locks see page.19, Kirk Lock version available on request (2) The kits must be ordered complete with a breaker. To allow for installation and transport each kit is supplied as a field mountable unit customized for use with the ordered draw out breaker cassette or a fixed pattern breaker. or the associated cables see page..22 Internal ccessories - actory mounted Maximum amount of installable internal accessories See page

18 ntelliguard G Notes Internal ccessories; actory mounted.19

19 ntelliguard G Internal ccessories - ield mountable or factory mounted variants see page.17 &.18 Order codes Motor Operators and losing oils Releases uxiliary ontacts ell larm ontacts Motor Operator envelope 1 Motor Operator envelope 2 & 3 at. No. Ref. No. at. No. Ref. No. at. No. Ref. No V GM01024R GM02024R V GM01048R GM02048R V GM01060R GM02060R V GM01110R GM02110R V GM01250R GM02250R V GM01048R GM02048R V GM01120R GM02120R V GM01240R GM02240R V GM01400R GM02400R V GM01440R GM02440R losing oil omm. losing oil (1) 2V GN024R G024R V - GN048R G048R V GN060R G060R V - GN120R G120R V - GN240R G240R V ; 250V GN277R G277R V GN400R G400R V GN440R G440R Undervoltage Shunt 2V GUVT024R GSTR024R V - GUVT048R GSTR048R V GUVT060R GSTR060R V - GUVT120R GSTR120R V - GUVT240R GSTR240R V ; 250V GUVT277R GSTR277R V GUVT400R GSTR400R V GUVT440R GSTR440R Power Rated 3NO & 3N GS3R (elivered as standard option in all ntelliguard G breakers & Isolators) Power Rated 8NO & 8N GS6R Power Rated 3NO & 3N GS5R Signal Rated 2NO & 2N Power Rated 4NO & 4N + Signal Rated 4NO & 4N GS8R hangeover GT1R Indication ontacts Power rated wired through sec. iscon. Signal rated wired Trip Unit (comm.) Position Indication ontacts assette //UVT/STR Release indicator GSP1R GSP2R Power rated on assette 1 hangeover per position GPS1R hangeovers per position GPS2R (1) esigned to be accessed through the Trip Unit communication option (Modbus or Profibus). Up to a voltage rating of 277V a extra coil operating/on push button is included in the kit for mounting on the reaker front facia..20

20 ntelliguard G Locking Mechanisms (1) Ronis astell Profalux Mounted on reaker The Ronis and Profalux devices allow 1 to 4 Locks to be placed. The astell device 1 Mounted on assette (2 devices for 2 locks are possible) at. No. Ref. No. at. No. Ref. No. at. No. Ref. No. GRONR GSR GPROR GRONR GPROR ssociated Locks (2) Ronis 1104 Lock (2) GRON Profalux 204Y Lock (2) GPRO astell S1 lock/k4 key (2) GS Operation Internal ccessories - ield mountable or factory mounted variants see page.17 &.18 ront ascia of reaker ounter; number of Operations GMNR Internal ccessories - ield mountable (1) Kirk Lock version available on request (2) Not available as actory Mounted accessory Motor Operator type 1 or 2 losing oil or ommand losing oil Undervoltage Release (3) Shunt Release Network Interlock Release uxiliary ontacts Power NO + N uxiliary ontacts Hi-idelity NO+N ell larm contacts (3) TM module (Time delay module) is mounted externally to the breaker Internal ccessories - ield mountable Maximum amount of installable internal accessories Signaling ontacts Releases indic. Power Signaling ontacts Releases indic. HI.id. reaker ready to close indication reaker Spring harged indication Position Indication ontacts (per Pos.) arthing evice Locking Mechanism reaker Locking Mechanism assette.21

21 ntelliguard G Internal ccessories - ield mountable Not available in a factory mounted variant Order codes ield mountable cables for interlocking of breakers (1) Interlock Scheme Interlock Type No. of ables Needed at. No. Ref. No. 1 cable per breaker, choose length as indicated 1 cable per breaker, able length 1 metre G choose length as indicated able length 1,6 metre G cable per breaker, able length 2 metre G choose length as indicated able length 2,5 metre G rk's 1 and 3: 1 cable per able length 3 metre G breaker, choose length as able length 3,5 metre G indicated able length 4 metre G rk. 2: 2 cables per breaker, choose length as indicated Time delay module for UVR release TM at. No. Ref. No. at. No. Ref. No. reaker arthing evice for Service GT- ccessories 60V GTM V GTM V GTM V GTM V GTM V GTM V GTM V GTM V GTM V GTM pole 4 pole ntelliguard G type 1 Maximum 1600 G16H G16H Maximum 2000 G20H G20H ntelliguard G type 2 Maximum 4000 G40M G40M ntelliguard G type 3 Maximum 6400 G64M G64M esignation onditioning Power Supply 1 phase V (2) GMPU onditioning Power Supply 1 phase V (2) GMPU onditioning Power Supply 1 phase / /415V (2) GMPU Power Supply - Input V or V - GPU Output 24V 0.6 mps (3) Trip unit, sealable transparent front cover GTUS Trip Unit attery Tester and Set up unit GTUTK Wall mounting rackets Wall Mounting rackets for nv. 1 & 2 GMTG (1) See for associated breaker and or cassette mounted kits page.18 (2) Obligatory when a fully functioning measurement unit is required (3) or G settings below 0,2 x In this aux. supply is needed.22

22 ntelliguard G Installation ccessories Not available in a factory mounted variant Operation at. No. Ref. No. oor langes & Interlocks ront ascia of reaker Padlocking device for Pushbuttons GP Operation Indicators ontact Wear Indicator env. 1-3 GNTW assette Mis insertion device GRPM oor lange fixed all types (1) GPR oor lange draw out all types (1) GPRW Installation ccessories oor scutcheon IP54 G54R oor Interlock on LT GLH oor Interlock on RIGHT GRH Phase seperators Lifting reakers (2) Lifting beam suited for use GL with envelope 1 & 2 Lifting beam suited for use GL with envelope 3 Set of 9 phase seperators for GJP V applications (3) (1) Is a spare, these devices are always supplied with the standard devices (2) esigned for use with commercially available lifting equipment. (3) Universal set including 3 pcs for envelope 1 & 2 fixed, 3 pcs. for envelope 1 & 2 drawout and 3 pcs for envelope 3..23

23 ntelliguard G Sensors for Trip Units or use with Ground fault Residual (sum) protection Rogowski coils: Order codes nvelope 1 nvelope 2 nvelope 3 at. No. Ref. No. at. No. Ref. No. at. No. Ref. No. 400 G04HNR G04HNR G07HNR G07HNR G08HNR G08HNR G10HNR G10HNR G13HNR G13HNR G16HNR G16HNR G20HNR G20HNR G25MNR G32LNR G32LNR G40LNR G40LNR G50LNR G64LNR Sensors for Trip Units or use with Ground fault protection, Source Ground Return method arth leg urrent Transformers - Kit includes 1 urrent Transformer. n interposing current transformer is also required (supplied with Trip Unit) nvelope 1 nvelope 2 nvelope 3 at. No. Ref. No. at. No. Ref. No. at. No. Ref. No. 400 G04HNT G04HNT G07HNT G07HNT G08HNT G08HNT G10HNT G10HNT G13HNT G13HNT G16HNT G16HNT G20HNT G20HNT G25MNT G32LNT G32LNT G40LNT G40LNT G50LNT G64LNT

24 assettes for use with reakers & Isolators in raw out Pattern; ield mountable ntelliguard G - References apply for assettes separately supplied for use with reakers or Isolator - With onnection modes as indicated in left column - ach cassette is supplied with safety shutters Universal Rear onnections assettes for raw out Pattern; fixed portion only 3 pole 4 pole Suited for use with (1) Rating () ntelliguard G -G types at. No. Ref. No. at. No. Ref. No. assette for envelope GG, GJ & GW type S, N & H GG13H2UR GG13H5UR GG, GJ & GW type S, N & H GG16H2UR GG16H5UR GG, GJ & GW type S, N & H GG20H2UR GG20H5UR assette for envelope 2 (2) GG, GJ & GW type N, & M GG20M2UR GG20M5UR GG, GJ & GW type N, H & M GG25M2UR GG25M5UR GG, GJ & GW type N, H & M GG32M2UR GG32M5UR GG, GJ & GW type N, H & M GG40M2UR GG40M5UR Remark: ach cassette is supplied with connection pads that can be rotated and used for Vertical or Horizontal connections. assette for envelope 3 (3) (1) GG & GJ type G, M & L GG64L2UR GG64L5UR Sensors & assettes Vertical rear onnections ront access onnections assette with dual vertical clusters and connection pads for limited de-rating envelope GH, GK, GJ & GZ type N.H & M GH32M2VR GH32M5VR GH, GK, GJ & GZ type N.H & M GH40M2VR GH40M5VR assette for envelope GG, GJ & GW type S, N & H GG13H2R GG13H5R GG, GJ & GW type S, N & H GG16H2R GG16H5R GG, GJ & GW type S, N & H GG20H2R GG20H5R assette for envelope GG, GJ & GW type, N, H & M GG20M2R GG20M5R GG, GJ & GW type N, H & M GG25M2R GG25M5R GG, GJ & GW type N, H & M GG32M2R GG32M5R GG, GJ & GW type N, H & M GG40M2R GG40M5R (1) 4th pole on Left. (2) assettes for envelope 2 are limited to a current of 3200 when connected in horizontal mode onnected in vertical mode a 4000 rating is achieved (3) The assette for envelope 3 is limited to a current of 5000 when connected in horizontal mode onnected in vertical mode it has a rating of This cassette type is NOT depicted here.25

25 ntelliguard G ield Mounted (spare) Trip Units lways specify Nominal current and reaker serial Number on Ordering GT- LT- G asic functionality esignation xtended functionality at. No. Ref. No. LT ST I 2 t on I 2 t on ST GT- Trip Unit with: None GTG00K2-SR LT- 0,2-1 x In = Ir LT ST I 2 T ON or O ST G I 2 T ON or O G GT-Rating Plug Required for all T types GTPUNI Order codes GT- S LT- G LT ST G G I 2 t on ST I i GT-S Trip Unit Modbus ommunication GTG00K4-2SR LT- 0,2-1 x In = Ir LT ST I 2 T ON or O ST G I 2 T ON or O G I GT-Rating Plug Required for all types GTPUNI GT- N LT- G LT ST ST G I hi GT-N Trip Unit Measurement unit (1) LT- 0,2-1 x In = Ir Modbus ommunication LT Zone Selective Interlock on ST, ST I 2 T ON or O I & G ST G I 2 T ON or O G I ext. GTG00K4T6SR GT-Rating Plug Required for all types GTPUNI

26 ntelliguard G ield Mounted (spare) Trip Units lways specify Nominal current and reaker serial Number on Ordering GT- H G LT- asic functionality esignation xtended functionality at. No. Ref. No. LT ST xtended functionality LT G ST RLT i GT-H Trip Unit with: LT and shape hoice (LT or LT) GTG00N5T8SR LT- 0,2-1 x In = Ir ual G Protection (Res./Sum or T) -OR- Zone Selective Interlock on ST, I & G LT x In = Ir Measurement Unit (1) LT ata aquisition & Relay functionality ST I 2 T ON or O RLT Instantaneous ST Modbus ommunication G or G (2) sum. I 2 T ON or O With standard Instaneous -N/OR- Idem with xtended Instananeous GTG00N7T8SR G (2) T I 2 N ON or O (3) G LT and shape hoice (LT or LT) GTG00N5T9SR I or I ext. ual G Protection (Res./Sum or T) RLT Zone Selective Interlock on ST, I & G Measurement Unit (1) ata aquisition & Relay functionality RLT Instantaneous Profibus ommunication With standard Instaneous Idem with xtended Instananeous GTG00N7T9SR LT and shape hoice (LT or LT) GTG00N6T8SR ual G larm (Res./Sum or T) Zone Selective Interlock on ST, I & G Measurement Unit (1) ata aquisition & Relay functionality RLT Instantaneous Modbus ommunication With standard Instaneous Idem with xtended Instananeous GTG00N8T8SR LT and shape hoice (LT or LT) GTG00N6T9SR ual G larm (Res./Sum or T) Zone Selective Interlock on ST, I & G Measurement Unit (1) ata aquisition & Relay functionality RLT Instantaneous Profibus ommunication With standard Instaneous Idem with xtended Instananeous GTG00N8T9SR GT-Rating Plug Required for all types GTPUNI GT Trip Unit with NO protection (1) n auxiliary Power onditioner is obligatory when a fully functioning measurement is required see page.22 (2) oes NOT trip the associated ntelliguard G reaker, UT produces an larm signal (3) The use of an interposing current transformer is required. (supplied with Trip Unit) I hi (or Non utomatic types) G3G00K-SR lectronic Trip Units.27

27 ntelliguard G Spare Parts reaker rc hutes nvelope 1 nvelope 2 nvelope 3 at. No. Ref. No. at. No. Ref. No. at. No. Ref. No. rc hute for 1 pole G20HHT G40MHT G64LHT Order codes reaker ixed rcing ontacts assette Shutters Set for 1pole S & N types G20NR Set for 1pole H type G20HR Set for 1pole & N types G40NR Set for 1pole H & M types G40MR Set for 1pole L type G64LR System with Interlock 3 pole G20H2SSL G40M2SSL G64L2SSL System with Interlock 4 pole G20H5SSL G40M5SSL G64L5SSL assette Racking Handle Spare Racking Handle GRHN GRHN GRHN ront acia G G G Set of 4 spare Lock cams for use GRONS GRONS GRONS with Ronis 1104 locks assette luster ontacts reakers and assette Spare uxiliary isconnect plugs Sets per pole urrent Rating G13HLS urrent Rating 1600 G16HLS urrent Rating 2000 G20HLS urrent Rating 2000 G20MLS urrent Rating 2500 G25MLS urrent Rating 3200 G32MLS urrent Rating 4000 G40MLS urrent Rating 5000 G50LLS urrent Rating 6400 G64LLS Set of Universal luster Pliers GUNI GUNI GUNI or ixed reaker 1 39 pole set or ixed reaker 1 78 pole set or raw out reaker 1 39 pole set (two can be mounted) GSTR GSTR GSTR GSTR GSTR GSTR GSWTR GSWTR GSWTR GT Trip Unit with NO protection (Suited for Non utomatic type) G3G00K-SR (1) The original breaker serial number must be indicated on ordering.28

28 ntelliguard G Notes Spare Parts.29

29 ntelliguard G Global atalogue number structure - reaker - odes built in the indicated manner can be used as an alternative ordering method - The breaker and its operation mode (Manual or lectrical) 1st digit 3rd & 4th digit 6th digit 7th digit Order codes product belonging to the ntelliguard G breaker line Nominal current rating of the product ixed Pattern or raw out Pattern moving portion and Number of Poles 3 Pole ixed Pattern 4 3 pole raw-out Moving Portion 4 Pole ixed Pattern 6 4 pole raw-out Moving Portion 1 3 lectrically or Hand Operated lectrical at: 24V 48V 60V V 250V 48V G V H V J V K V M 440V N Manual G G 1 3 H 4 ircuit reaker Product Type ircuit reaker with reduced de-rating Non utomatic (Switch) no MR Non utomatic (Switch) with MR Non utomatic (Switch) 100% rated no MR Non utomatic (Switch) 100% rated with MR G H J W or an overview of the valid combinations indicating the available options see page.34 K Z Interruption / short-circuit withstand rating of the product Icu = Ics Icw ode 50k 50k S 65k 65k N 85k 65k H 85k 85k 100k 85k M 100k 100k G 150k 100k L Voltage Rating Standard losing oil ommand losing oil (1) 24V M 40-48V 48V P 60V Q V - R V - G T 250V 277V H U V K W 440V L Y Manual If lectrically Operated add 1 losing oil by indicating voltage rating code. If manual use an as indicated 2nd digit 5th digit 8th digit (1) Is supplied with a Push utton for Local reaker operation (fits on breaker front facia).30

30 Global atalogue number structure - reaker ntelliguard G 9th digit Shunt Release Voltage Rating 24V 40-48V 48V 60V ode V V - G 250V 277V H V K 440V Network Interlock 1 None dd 1st Shunt Release by indicating voltage rating code. if not needed use an as indicated, or '1' for a network Interlock L Undervoltage Release Voltage Rating ode 24V V 48V 3 60V V V V 277V V W 440V None dd 1st UVR release by using the indicated code. If a 1 is chosen as a 9th digit the use of a Network Interlock with equivalent voltage is assumed. The use of an indicates no Release installed. Y - odes built in the indicated manner can be used as an alternative ordering method - reaker mounted accessories and Trip Unit 11th digit 2nd Shunt or UVR Release Voltage Rating Shunt code UVR code 24V V 48V 3 60V V V - G 7 250V 277V H V K W 440V L Y None dd a 2nd or UVR Shunt Release by indicating the voltage rating code. if not needed use an as indicated th digit uxiliary Switches & onfiguration ode to be added (2) 3NO+3N (Power Rated) (1) 2 G H S T 8NO+8N (Power Rated) 4 3NO/3N (Power Rated) + 2NO/2N (Signal) 6 J K L M N P Q R U V 4NO/4N (Power Rated) + 4NO/4N Signal) 8 No other contacts installed oil Signaling ontact Power (1 NO on Secondary isconnect) - lose oil or command close coil ell larm Switch & Operations ounter oil Signaling ontact High idelity through Trip Unit - lose oil or command close coil oil Signaling ontact Power (1 NO on Secondary isconnect) - 1st Shunt oil Signaling ontact High idelity through Trip Unit - 1st Shunt oil Signaling ontact Power (1 NO on Secondary isconnect) - 1st UVR oil Signaling ontact High idelity through Trip Unit - 1st UVR oil Signaling ontact Power (1 NO on Secondary isconnect) - 2nd ST or 2nd UVR dd one of the chosen combinations by using one of the indicated codes. ode to be added ell larm 1 NO Mechanical Operations ounter K L M ell larm 1NO & Mechanical Operations counter G H J Ready to lose contact 1 NO Power Rated on Secondary terminals 1 Ready to lose contact 1 NO Signal Rated on Secondary terminals 2 Ready to lose contact 1 NO Signal Rated connected through Trip Unit 3 None No other contacts installed Ready to lose contact 1 NO Power Rated on Secondary terminals through Trip Unit - 2nd ST or 2nd UVR oil Signaling ontact High idelity Ready to lose contact 1 NO SIgnal Rated on Secondary terminals oil Signaling ontact Power (1 NO on Secondary isconnect) - ll installed devices /, ST, or UVR Ready to lose contact 1 NO SIgnal Rated connected Through Trip Unit oil Signaling ontact Hight idelity (1 NO - Through Trip Unit) - ll installed devices. /, ST, or UVR Global atalogue number structure 10th digit 12th digit (1) ach standard breaker or Isolator is normally supplied with 3 NO+3N ux.contacts (option 2).31

Trip Units - Factory mounted. GT-E Trip Unit with: None GTG00K1-SF LT-C 0,2-1 x In = Ir LTDB. ST I²T ON or OFF STDB

Trip Units - Factory mounted. GT-E Trip Unit with: None GTG00K1-SF LT-C 0,2-1 x In = Ir LTDB. ST I²T ON or OFF STDB ntelliguard G Trip Units - actory mounted GT- LT- asic functionality esignation xtended functionality at. No. Ref. No. GT- Trip Unit with: None GTG00K-S 408800 LT- 0, - x In = Ir I²T ON or O GT-Rating

More information

GE Consumer & Industrial. Entelliguard G. New. Power Circuit Breaker. Uncompromising, Fast & Selective

GE Consumer & Industrial. Entelliguard G. New. Power Circuit Breaker. Uncompromising, Fast & Selective GE Consumer & Industrial Entelliguard G @ Power Circuit Breaker Uncompromising, Fast & Selective New 2 0 0 9 Introduction 1 Performance Rating 4 Application Guide 7 Ordering Codes 14 EntelliGuard G New

More information

GE Industrial Solutions. EntelliGuard G. New. Power Circuit Breaker. Uncompromising, Fast & Selective

GE Industrial Solutions. EntelliGuard G. New. Power Circuit Breaker. Uncompromising, Fast & Selective GE Industrial Solutions EntelliGuard G New Power Circuit Breaker Uncompromising, Fast & Selective GE GE is a diversified organization covering a myriad of market segments, including infrastructure, finance

More information

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C.3 General characteristics. C.4 Fixed circuit breaker. C.5 Withdrawable circuit breakers

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C.3 General characteristics. C.4 Fixed circuit breaker. C.5 Withdrawable circuit breakers SPETRONI SP - Air circuit breakers Summary.3 General characteristics.4 Fixed circuit breaker.5 Withdrawable circuit breakers.6 haracteristics.7 RMS 7: protection and control unit.10 RMS 9: protection and

More information

Technical catalogue. Emax Low voltage air circuit-breakers. Hotline:

Technical catalogue. Emax Low voltage air circuit-breakers.   Hotline: Technical catalogue Emax Low voltage air circuit-breakers www.alobitanbd.com Hotline: 01711548558 PAGE : 02 The new Emax have received innumerable international certifications and approval by the major

More information

$

$ ircuit reakers or I-LIN Panelboards and Switchboards lass 0, 5, 70, 830 8 PNLORS 8-32 LI3 7.5 in (190 mm) L 7.5 in (190 mm) M, MH 2- and 3-Pole 9 in (229 mm) N, N 2- and 3-Pole 15 in (381 mm) Square ll

More information

3 - Protection components Circuit-breakers

3 - Protection components Circuit-breakers Contents - Protection components Circuit-breakers for the motor protection Selection guide..............................................page /2 Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Mould circ. Moulded case circuit-breakers

Mould circ. Moulded case circuit-breakers Mould circ Moulded case circuit-breakers Moulded case circuit-breakers Tmax Contents Power distribution circuit-breakers Technical Data... 7/6 Ordering details Reading information... 7/15 Tmax T1... 7/20

More information

150 C 30 F B D 8L 152H C 30 F BD 43 8L

150 C 30 F B D 8L 152H C 30 F BD 43 8L ulletin SM - Smart Motor ontrollers atalog Number Explanation Open and Non-ombination F D L a b c d e f g a ulletin Number Solid-State ontroller b ontroller Type SM- c mpere s N F d Enclosure Type Open

More information

ECL03B1AAA 20A 120V Lighting Contactor

ECL03B1AAA 20A 120V Lighting Contactor 80 South Street 7-7, TX Nacogdoches Phone: --71 Fax: -0-8 L01 0 V Lighting ontactor aton orp Number L01 Manufacturer aton orp escription Lighting ontactor, lectrically eld; Pole; 77/80 V (Filament Lamp),

More information

Miniature Circuit Breakers B4/B6/B10, Residual Current Devices & Isolating Switches

Miniature Circuit Breakers B4/B6/B10, Residual Current Devices & Isolating Switches Miniature ircuit reakers 4//, esidual urrent evices & Isolating Switches The IMO range of miniature circuit breakers have been designed for protection of electrical installations against overload and short

More information

CT08-5 Taped A 5P80 CT16-5 Taped A 5P80. * In is the value of the primary nominal current of the transformer.

CT08-5 Taped A 5P80 CT16-5 Taped A 5P80. * In is the value of the primary nominal current of the transformer. SI-B Overcurrent and Earth Fault Protection Relay for Secondary istribution ual & Self Powered Main characteristics The SI-B is a ual & Self powered overcurrent protection relay using the operating current

More information

Data Sheet. Earth Leakage Relay RISH ELR/ELR+/ELR VI/ELR VI(NE) A V RISH ELR VI. Record. Digital Protection Relay RESET TEST ENTER

Data Sheet. Earth Leakage Relay RISH ELR/ELR+/ELR VI/ELR VI(NE) A V RISH ELR VI. Record. Digital Protection Relay RESET TEST ENTER ata Sheet arth eakage Relay RISH R/R+/R VI/R VI() RISH R VI 8.8. 8. 8. V R-1 R-2 igital Protection Relay K RST TST TR nalyze ata Sheet arth eakage Relay RISH R RISH arth eakage Relay is used to etect and

More information

Contactors & Relays. Contactors & Relays Manual Motor Starters Miniature Circuit Breakers Earth Leakage Isolators. Pg

Contactors & Relays. Contactors & Relays Manual Motor Starters Miniature Circuit Breakers Earth Leakage Isolators. Pg Contactors & Relays Contactors & Relays Manual Motor Starters Miniature Circuit Breakers Earth Leakage Isolators Pg 223 230 231 232 232 Contactors & Relays Contactor - GMC Series 3 Pole (240V) AC 1 Rati

More information

04 Page. MCCBs characteristics 94. MCCBs & accessories selection guide 96. MCCBs x MCCBs x MCCBs h

04 Page. MCCBs characteristics 94. MCCBs & accessories selection guide 96. MCCBs x MCCBs x MCCBs h This section includes moulded case circuit breakers, manual and automatic transfer switches and load break switches which are utilised for the switching, protection and distribution of low voltage installations.

More information

C-Series. Circuit Breaker.

C-Series. Circuit Breaker. -Series ircuit Breaker The -Series hydraulic/magnetic circuit breakers are ideal for applications that require higher amperage and voltage handling capability in a smaller package. They are available in

More information

Miniature circuit breakers. Residential current circuit breakers. Busbar systems. Comfort functions/energy control. Residential enclosures

Miniature circuit breakers. Residential current circuit breakers. Busbar systems. Comfort functions/energy control. Residential enclosures .2..4.5.6.7 Technical data Series ME07 Standard range S, S, 0/690V/AC High performance range H, 0/690V/AC High performance range H/S, 000V/AC Disconnecting switch MET DC circuit breaker ME 6T up to 0V/DC

More information

Maintenance/Connection/Installation Service life C/O cyclesx1000

Maintenance/Connection/Installation Service life C/O cyclesx1000 EasyPact MVS 2016 CPB100000 CPB100014 Circuit breaker. Switch disconnector. Common characteristics Number of poles Rated insulation voltage (V) Impulse withstand voltage (kv) Rated operational voltage

More information

SEL-787-2, -3, -4 Transformer Protection Relay Standard Features

SEL-787-2, -3, -4 Transformer Protection Relay Standard Features SEL-787-2, -3, -4 Transformer Protection Relay Standard Features Protection Phase ifferential Elements Overcurrent reaker Monitoring reaker Failure ardware 6 urrent Inputs Slot Z 2 igital Inputs (I) Slot

More information

TOYO AUTOMATIC TRANSFER SWITCH

TOYO AUTOMATIC TRANSFER SWITCH TOYO UTOMT TRNSR SWT Safety ach phase is enclosed separately to improve the breaking capacity and safety. ach phase of TOYO instantaneous excitation type TS is molded and enclosed individually to improve

More information

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE PAGE 262400-1 SECTION 262400 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

RISH ELR Earth Leakage Relay Preliminary Datasheet True RMS Measurement Trip relay cum DPM CBCT Open Detection 4 digit 7 segment LED display

RISH ELR Earth Leakage Relay Preliminary Datasheet True RMS Measurement Trip relay cum DPM CBCT Open Detection 4 digit 7 segment LED display RISH R arth eakage Relay Preliminary atasheet Technical atasheet RISH R RISH arth eakage Relay is used to etect and protect instruments from leakage current. RISH R VI RISH R VI RISH R VI is used to protect

More information

Redundant Bus Protection Using High-Impedance Differential Relays

Redundant Bus Protection Using High-Impedance Differential Relays Redundant Bus Protection Using High-Impedance Relays Josh LaBlanc, Schweitzer Engineering Laboratories, Inc. (formerly of Minnesota Power) Michael Thompson, Schweitzer Engineering Laboratories, Inc. 2018

More information

TeSys circuit-breakers Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7

TeSys circuit-breakers Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7 Presentation Thermal-magnetic motor circuit-breakers types GV, GV and GV7 GV-ME, GV-P, GV-ME and GV7-R motor circuit-breakers are -pole thermal-magnetic circuit-breakers specifically designed for the control

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Remote ontrol Switchers STLLTION STRUTIONS L LT The is a controlled outlet device, capable of switching up to mperes of continuous current to a component or power strip. It can be switched ON and O by

More information

Protective Relays Digitrip 3000

Protective Relays Digitrip 3000 New Information Technical Data Effective: May 1999 Page 1 Applications Provides reliable 3-phase and ground overcurrent protection for all voltage levels. Primary feeder circuit protection Primary transformer

More information

Motor Protection Circuit Breaker Series 8146/5-V27

Motor Protection Circuit Breaker Series 8146/5-V27 www.stahl.de > For protection of Ex e and Ex d motors > Protects electric lines and plant equipment > Thermal overcurrent release, adjustable, phase failure sensitive > Electromagnetic quick release >

More information

Timers RTE. RTE Series Analog Timers

Timers RTE. RTE Series Analog Timers RTE RTE Key features: 20 time ranges and 10 timing functions Time delays up to 600 hours Space-saving package High repeat accuracy of ± 0.2% ON and timing OUT LE indicators Standard 8- or 11-pin and 11-blade

More information

Versatile air circuit-breakers up to 6300 A for economically-optimised solutions.

Versatile air circuit-breakers up to 6300 A for economically-optimised solutions. www.eaton.com www.moeller.net Versatile air circuit-breakers up to 6300 A for economically-optimised solutions. New Products Catalogue 2009 Circuit Breakers IZMX16, IZM26 The power of fusion. 1874 1886

More information

Modeion OTHER ACCESSORIES OF MOULDED CASE CIRCUIT BREAKERS

Modeion OTHER ACCESSORIES OF MOULDED CASE CIRCUIT BREAKERS OTHER ACCESSORIES OF MOULDED CASE CIRCUIT BREAKERS P Other accessories DELAY UNIT Type Product code Description Weight [kg] Package [pc] BZ-BX-X230-A 36696 enables to delay the undervoltage release tripping

More information

Components for Marine applications

Components for Marine applications Components for Marine applications Imagination GE imagination at work. at work v. 10-2015 GE Industrial Solutions Leading the future of electrification GE Industrial Solutions is leading the future of

More information

www. ElectricalPartManuals. com Generator Differential Relay MD32G Rotating Machine Differential Relay

www. ElectricalPartManuals. com Generator Differential Relay MD32G Rotating Machine Differential Relay Generator Differential Relay The MD3G Rotating Machine Differential Relay is a member of Cooper Power Systems Edison line of microprocessor based protective relays. The MD3G relay offers the following

More information

XIOC technology and networking modules

XIOC technology and networking modules / XIO XIO digitale and analog input/output modules XIO technology and networking modules XIO the compact I/O and much more XIO are local expansion modules for direct connection to all Xontrol controllers.

More information

MOTOR / PUMP PROTECTION RELAYS

MOTOR / PUMP PROTECTION RELAYS MOTO / PUMP POTETI ELAS These relays are useful for protection of 3-phase A induction motors against various hazards. With their unique advantages they eliminate use of a thermal/bimetal relay for motor

More information

11/0 IZM circuit-breakers, IN switch-disconnectors

11/0 IZM circuit-breakers, IN switch-disconnectors 11/0 IZM circuit-breakers, IN switch-disconnectors Contents IZM circuit-breakers, IN switch-disconnectors 11/1 from 630 A 6300 A Page Description 11/2 Technical overview 11/4 Overview of functions for

More information

CDV 22, 62. Voltage Controlled Overcurrent Relay GRID PROTECTION

CDV 22, 62. Voltage Controlled Overcurrent Relay GRID PROTECTION PROTECTION CDV 22, 62 Voltage Controlled Overcurrent Relay CDV22 relay is used for overload and fault protection for ac generators when the sustained short circuit current is less than the full load current.

More information

Open Type. SAO12b SAG12b Use Size 0 Use Size 0. SBO2b SBG2b SBW12b SBW22b

Open Type. SAO12b SAG12b Use Size 0 Use Size 0. SBO2b SBG2b SBW12b SBW22b www.schneider-electric.us SO, -Pole Starter ull Starters Rated lass 86 / Refer to atalog 80T70 eneral nformation S magnetic starters are used for full-voltage starting stopping squirrel cage motors. overload

More information

www. ElectricalPartManuals. com Basler Electric P. 0. BOX 269 HIGHLAND, ILLINOIS 62249, U.S.A. PHONE FAX

www. ElectricalPartManuals. com Basler Electric P. 0. BOX 269 HIGHLAND, ILLINOIS 62249, U.S.A. PHONE FAX The BE1-47N Voltage Phase Sequence Relay provides protection for rotating equipment from the damaging effects of excessive negative sequence voltage resulting from phase failure, phase unbalance and reversed

More information

For more information, please visit or call toll free at

For more information, please visit   or call toll free at GT3 GT3 Key features: 4 selectable operation modes on each model External start, reset, and gate inputs Panel mount or socket mount Large variety of timing functions and output status indicating LEs UL,

More information

CD214C Transient Voltage Suppressor Diode Series

CD214C Transient Voltage Suppressor Diode Series *RoHS OMPLINT eatures Lead free RoHS compliant* Surface Mount SM package Standoff Voltage: 5. to 17 volts Power issipation: 15 watts Model 214 is currently available, although not recommended for new designs.

More information

AEG Low Voltage Component

AEG Low Voltage Component AEG Low Voltage omponent Technology transfers reliable power We are striving to create a peaceful and comfortable life for you. AEG: We believe that power system can be very simple. Main distribution system

More information

HELLROARING TECHNOLOGIES, INC. P.O. BOX 1521 POLSON, MT

HELLROARING TECHNOLOGIES, INC. P.O. BOX 1521 POLSON, MT HELLRORING TEHNOLOGIES, IN. P.O. OX 1521 POLSON, MT 59860 406 883-3801 HTTP://WWW.HELLRORING.OM SLES12@HELLRORING.OM SSR-15240-60V-xx The SSR-15240-60V-xx are designed for positive D load switching (solid

More information

Controls Contactors and Contactor Assemblies Special Applications

Controls Contactors and Contactor Assemblies Special Applications Controls Contactors and Contactor Assemblies Special Applications Price groups 1B, 1H /2 Introduction More information can be found on the Internet: see the opening information, page 13 - Contactors for

More information

Informative (*Customer to review then remove this page from submitted witness test procedure)

Informative (*Customer to review then remove this page from submitted witness test procedure) WITNESS TEST PROEDURE TEMPLTE National Grid Use Only: Doc. # PR.756..12.16 Publication Date: 12/6/16 Document Sponsor: Neil F. Larake, Retail onnections Policy & Standards Next Scheduled Review: 8/1/17

More information

www. ElectricalPartManuals. com Transformer Differential Relay MD32T Transformer Differential Relay

www. ElectricalPartManuals. com Transformer Differential Relay MD32T Transformer Differential Relay Transformer Differential Relay The MD3T Transformer Differential Relay is a member of Cooper Power Systems Edison line of microprocessor based protective relays. The MD3T relay offers the following functions:

More information

from 0.5 to 125 A Electrical characteristics Sensitivity type (ma) a AC Electrical auxiliaries Auxiliary and alarm switches (OF-SD)

from 0.5 to 125 A Electrical characteristics Sensitivity type (ma) a AC Electrical auxiliaries Auxiliary and alarm switches (OF-SD) Acti 9 Acti 9 circuit reakers from 0.5 to 125 A 056903N-32_SE.eps 056806N-28_SE.eps PB104440_28.eps PB107141_28.eps Acti 9 circuit reaker C120N Numer of poles 1 2-3-4 Electrical characteristics Rated current

More information

Switches Unlimited Contact: Phone: Fax:

Switches Unlimited Contact: Phone: Fax: Phone: 8--87 Fax: 78-67-67 - C Coil Three Pole - Series C7 C7 Non-Reversing, Three Pole With C Coil, Series C7 (Open type only) [] Ratings for Switching C Motors (C / C / C) kw (5 Hz) UL/CS HP (6 Hz) uxiliary

More information

PARAMETER LIST PARAMETER LIST

PARAMETER LIST PARAMETER LIST PRMETER LIST PRMETER LIST dvanced Genset Controller, GC 200 larm list Parameter list Document no.: 489340605L SW version 4.2.x or later GC 200 parameter list 489340605 UK Contents: General information...

More information

Harmonic Correction Unit NEMA 1 Enclosure

Harmonic Correction Unit NEMA 1 Enclosure ffective: June 2001 Page 1 New Information Harmonic orrection Unit ontents Description Page Harmonic orrection Unit Specifications.......... 2 Sizing and Selection.............................................

More information

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax : NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata - 700 032, Tel : 033 2477 3126; Fax : 033 2477 2403 www.ntplindia.com SPECIFICATION NTPL MAKE MICRO-CONTROLLER BASED AUTOMATIC 50KV/10A AC HIGH VOLTAGE

More information

Low voltage Air Circuit Breaker IZMX with Power Xpert Releases PXR. Product Catalogue

Low voltage Air Circuit Breaker IZMX with Power Xpert Releases PXR. Product Catalogue Low voltage Air Circuit Breaker IZMX www.eaton.eu Switch Disconnector and Air Circuit Breaker... with Power Xpert Releases PXR Product Catalogue Energizing a world that demands more. We deliver: Electrical

More information

Compact NS630b to 1600

Compact NS630b to 1600 Compact NS630 to 1600 Fixed circuit reakers The diagram is shown with circuits de-energised, all devices open, connected and charged and relays in the nmal position. Power Control unit DB8378.eps Power

More information

3AH Vacuum Circuit-Breakers

3AH Vacuum Circuit-Breakers s H Vacuum Medium-Voltage Equipment Catalog HG. June Selection and ing Data H Vacuum H Vacuum Description R-HG-0a eps Siemens 8BJ0 medium-voltage withdrawable switchgear with H vacuum circuit-breaker on

More information

ISO 9001:2000 SIA C. Dual Power Overcurrent Protection Relay INSTALLATION GUIDE. Guia_SIA-C_Rev / 32

ISO 9001:2000 SIA C. Dual Power Overcurrent Protection Relay INSTALLATION GUIDE.   Guia_SIA-C_Rev / 32 ISO 9001:2000 SIA Dual Power Overcurrent Protection Relay INSTALLATION GUIDE www.fanox.com Guia_SIA-_Rev. 01 1 / 32 1.USER INTERFAE... 4 1.1. Revision A... 4 1.2. Revision B and... 4 1.3. Bistable magnetic

More information

SMCJ Transient Voltage Suppressor Diode Series

SMCJ Transient Voltage Suppressor Diode Series *RoHS OMPLINT eatures RoHS compliant* Surface Mount SM package Standoff Voltage: 5. to 495 volts Power issipation: 15 watts pplications I 6-4-2 S (Min. Level 4) I 6-4-4 T I 6-4-5 Surge SMJ Transient Voltage

More information

UL Listed power distribution blocks

UL Listed power distribution blocks Technical ata 10537 ffective September 2017 Supersedes ugust 2016 atalog number example: P323-3 is a 3-pole P323 Where: The prefix P323 defines the block s lineside characteristics (i.e., one conductor

More information

APPLICATION: The heart of the system is a DSR 100 Digital Static Regulator used in conjunction with standard SCR based rectifier bridges.

APPLICATION: The heart of the system is a DSR 100 Digital Static Regulator used in conjunction with standard SCR based rectifier bridges. APPLICATION: Basler Electric offers a New Line of digitally controlled brush (static) or brushless excitation systems designed for use with existing Hydro, Gas as well as Diesel driven generators requiring

More information

CC-Link Compatible AC Servo Amplifier <MR-J3-T type> with Built-in Positioning Function

CC-Link Compatible AC Servo Amplifier <MR-J3-T type> with Built-in Positioning Function MO LM/ G T P R M Fn SHIFT ES E B 1STEP. F PRU03 TEST F ST OP RESET General-Purpose Servo MELSERO-J3 ew Product Release S0-E -Link ompatible Servo mplifier with Built-in Positioning Function

More information

DPX³ 250 Electronic 4P - ModbusTable LGR EN v1.01.xls

DPX³ 250 Electronic 4P - ModbusTable LGR EN v1.01.xls GENERAL MODBUS TABLE ORGANIZATION Starting of the Group s Starting of the Group s System Version (Release) System Version (Build) Group Name (Text) Group Code Group Complexity Group Version 1638 000 01

More information

SMCJ Transient Voltage Suppressor Diode Series

SMCJ Transient Voltage Suppressor Diode Series *RoHS OMPLINT eatures RoHS compliant* Surface Mount SM package Standoff Voltage: 5. to 17 volts Power issipation: 15 watts pplications I 6-4-2 S (Min. Level 4) I 6-4-4 T I 6-4-5 Surge SMJ Transient Voltage

More information

Capacitor Switching Contactors

Capacitor Switching Contactors Capacitor Switching D385E51 Technical catalogues and news under: www.benedict.at Motor-Starter Mini- Overload Relays Capacitor Switching Motor-Starters Modular Circuit Breakers M4-32T... up to 32A M4-32R..

More information

DIVISIONE ELETTRONICA E SISTEMI UHR4N DIGITAL MULTIFUNCTION PROTECTION RELAY 100% AND 95% GENERATOR STATOR EARTH FAULT USER MANUAL

DIVISIONE ELETTRONICA E SISTEMI UHR4N DIGITAL MULTIFUNCTION PROTECTION RELAY 100% AND 95% GENERATOR STATOR EARTH FAULT USER MANUAL DIVISIONE ELETTRONICA E SISTEMI UHR4N DIGITAL MULTIFUNCTION PROTECTION RELAY 100% AND 95% GENERATOR STATOR EARTH FAULT USER MANUAL P500D824 September 2004 INDEX INDEX 1 GENERAL CHARACTERISTICS... 1 1.1

More information

Series P. Applications

Series P. Applications Ratings 25 800 VA Voltage Primary 230 / 400 / 460 V range Secondary 6 / 12 V 12 / 24 V 24 / 48 V 115 / 230 V Voltage selection by means of metal connection bridges, offering the full rated power at any

More information

PD300. Transformer, generator and motor protection Data sheet

PD300. Transformer, generator and motor protection Data sheet PD300 Transformer, generator and motor protection Data sheet DSE_PD300_eng_AO No part of this publication may be reproduced by whatever means without the prior written permission of Ingeteam T&D. One of

More information

Terms and Definitions. Contact Definition. Symbol. Explanation D CC. Check Contact H L. Contact Material

Terms and Definitions. Contact Definition. Symbol. Explanation D CC. Check Contact H L. Contact Material SIGNLLING RELY High Reliability and Stability Eseries Pseries Fseries EO ER EM EK E E ES EU EUS ELI ESR ERU P PV PU PR FL FP F s time passes, technical innovation is advancing. New technical concepts and

More information

B250, 2-Way, Characterized Control Valve Stainless Steel Ball and Stem

B250, 2-Way, Characterized Control Valve Stainless Steel Ball and Stem 250, 2-ay, haracterized ontrol Valve Stainless Steel all and Stem pplication This valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating or cooling coils.

More information

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range 13.

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range 13. G3 G3 Key features: 4 selectable operation modes on each model External start, reset, and gate inputs Panel mount or socket mount Large variety of timing functions and output status indicating LEs Specifications

More information

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You Circuit Breakers Excerpt from Master Catalogue Circuit Breakers Specifically For You Hydraulic-magnetic technology ensures reduced nuisance tripping with temperature variance Always holds 00% rated current

More information

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2 Ultrasonic energy meter Type 775 Installation Guide Edition 1.2 UK-QB101575 / 29.05.2012 Brunata a/s is a Danish owned company. We have more than 90 years of experience within developing and producing

More information

Technical catalogue. Emax. Low voltage air circuit-breakers 1SDC200006D0205

Technical catalogue. Emax. Low voltage air circuit-breakers 1SDC200006D0205 Technical catalogue Emax Low voltage air circuit-breakers 1SDC200006D0205 Overview of the SACE Emax family Fields of application 1 E1 E2 Automatic circuit-breakers E1B E1N E2B E2N E2S E2L Poles [No.] 3-4

More information

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories Mini Contactor Relays 4-pole J7KN-R ) Main contactor C & DC operated 4-, 6- and 8-pole versions in different configurations Mirror contacts Screw fixing and snap fitting (35 mm DIN rail) Rated current

More information

Technical Data Accessories MCCBs Ex9M.

Technical Data Accessories MCCBs Ex9M. Auxiliary and signal contact units AX21, AL21 Contact units for auxiliary and signal contact functions are suitable for both M1 and M2 frame sizes It is possible to use ap to two units of AX21 plus 1 unit

More information

Switching Devices Contactors and Contactor Assemblies for Switching Motors

Switching Devices Contactors and Contactor Assemblies for Switching Motors Switching Devices Contactors and Contactor Assemblies for Switching Motors groups 41B, 41H / Introduction Power contactors for switching motors /5 General data /11 SIRIUS RT10 contactors, -pole,... 50

More information

C-Series. Circuit Breaker

C-Series. Circuit Breaker -Series ircuit Breaker The -Series hydraulic/magnetic circuit breakers are ideal for applications that require higher amperage and voltage handling capability in a smaller package. They are available in

More information

Modeion MOULDED CASE CIRCUIT BREAKERS BL1000S

Modeion MOULDED CASE CIRCUIT BREAKERS BL1000S G MOULDED CASE CIRCUIT BREAKERS BL1000S G BL1000S COMMERCIAL INFORMATION 3P Switching units, withdrawable device...g4 Overcurrent releases...g5 Signalling units...g5 Residual current monitor...h6 Current

More information

BE1-87G VARIABLE PERCENTAGE DIFFERENTIAL RELAY

BE1-87G VARIABLE PERCENTAGE DIFFERENTIAL RELAY BE1-87G VARIABLE PERCENTAGE DIFFERENTIAL RELAY The BE1-87G is a single or three-phase solid-state variable percentage differential relay designed to provide selective, high-speed, differential protection

More information

Micrologic control units 2.0 E X Y Z. Overview of functions. Functions and characteristics

Micrologic control units 2.0 E X Y Z. Overview of functions. Functions and characteristics Overview of functions All Masterpact circuit breakers are equipped with a Micrologic control unit that can be changed on site. Control units are designed to protect Power circuits and loads. Alarms may

More information

BE1-67N GROUND DIRECTIONAL OVERCURRENT RELAY FEATURES ADDITIONAL INFORMATION. FUNCTIONS AND FEATURES Pages 2-4. APPLICATIONS Page 2

BE1-67N GROUND DIRECTIONAL OVERCURRENT RELAY FEATURES ADDITIONAL INFORMATION. FUNCTIONS AND FEATURES Pages 2-4. APPLICATIONS Page 2 BE1-67N GROUND DIRECTIONAL OVERCURRENT RELAY The BE1-67N Ground Directional Overcurrent Relay provides ground fault protection for transmission and distribution lines by sensing the direction and magnitude

More information

LOGIC V I V I S U N. Pulse / Timer S E R I E S. Timed device activation via pulse output (horn, buzzer, blinking indicators)

LOGIC V I V I S U N. Pulse / Timer S E R I E S. Timed device activation via pulse output (horn, buzzer, blinking indicators) OI S E R I E S Timed device activation via pulse output (horn, buzzer, blinking indicators) Integrated electrical circuit replaces external pulse generators, timers and relays Independent dual channel

More information

P.O. BOX 1521 POLSON, MT SSR V-12C

P.O. BOX 1521 POLSON, MT SSR V-12C HELLRORING TEHNOLOGIES, IN. P.O. OX 1521 POLSON, MT 59860 406 883-3801 HTTP://WWW.HELLRORING.OM SUPPORT@HELLRORING.OM SSR-15275-30V-12 The SSR-15275-30V-12 is designed for positive D load switching (solid

More information

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

Miniature circuit-breakers S 280 UC series. System pro M. Technical data Technical data 11 Robbie Rd. / Avon, MA 02322 T:(508)513-1000 F:(508)513-1100 70 Ernest St. / Providence, RI 02905 T:(401)781-7100 www.controllerservice.com System pro M Prior to connection of aluminum

More information

page 2 of 86 Report reference No:

page 2 of 86 Report reference No: articulars: test item vs. test requirements 3. Classification 3.1. Utilization category: (A or B)... : A 3.2. Interruption medium: (air, vacuum, gas Break)... : Air 3.3. Design: (open construction, moulded

More information

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment T/3000 Substation Maintenance and Commissioning Test Equipment MULTI FUNCTION SYSTEM FOR TESTING SUBSTATION EQUIPMENT SUCH AS: CURRENT, VOLTAGE AND POWER TRANSFORMERS, ALL TYPE OF PROTECTION RELAYS, ENERGY

More information

Block Contactors. Contents. Panorama 3-pole Contactors... 2/2 4-pole Contactors... 2/4

Block Contactors. Contents. Panorama 3-pole Contactors... 2/2 4-pole Contactors... 2/4 /0 Block Contactors Contents Panorama -pole Contactors... / 4-pole Contactors... /4 -pole Contactors: Description and Ordering Details A 9... A 0 Contactors (a.c. Operated)... /6 A 4... AF 60 Contactors

More information

Application Description

Application Description - N Mechanically Held February ontents Description Page Product Description...... - Application Description... - Features................ - Operation.............. - Instructional Leaflets..... - Standards

More information

Curves TeSys Model U 0 Starter-controllers

Curves TeSys Model U 0 Starter-controllers Curves TeSys Model U 0 Tripping curves for control units LUCA, LUCB, LUCD Average operating times at 0 C according to multiples of the setting current, tolerance : ± 0 %. Time (s) 000 00 0 0, LUCD, poles

More information

RETROFITTING. Motor Protection Relay. Two mountings are available, Flush Rear Connection (EDPAR) or Projecting Rear Connection (SDPAR).

RETROFITTING. Motor Protection Relay. Two mountings are available, Flush Rear Connection (EDPAR) or Projecting Rear Connection (SDPAR). RETROFITTING Motor Protection Relay NPM800R (R2 case) and NPM800RE (R3 case) are dedicated to the refurbishment of 7000 series (R2 and R3 cases) of CEE relays providing the protection of medium voltage

More information

Options M-12 quick-disconnect connector. MTS (Machine Test Signal) Muting through RM-3 module Explosion-proof versions available

Options M-12 quick-disconnect connector. MTS (Machine Test Signal) Muting through RM-3 module Explosion-proof versions available perimeter access guarding P00 ev..0 S S Description P00 Perimeter ccess Guarding Device Operating range of 0 m Three scan codes to eliminate cross-talk Short/long operating range selector switch esponse

More information

Series PROPULSION TELEGRAPH PRIME MOVER CONTROLS INC.

Series PROPULSION TELEGRAPH PRIME MOVER CONTROLS INC. PROUCT BULLETIN SB 8202-4000 Series 8202-4000 The PMC series 8202-4000 Engine Order Telegraph is a dependable and compact marine telegraph for single or twin screw systems. The 8202 functions independently

More information

DZM Installation Diagram Sheet 1 - DZM

DZM Installation Diagram Sheet 1 - DZM Sheet - ZM Power conections Sheet GN ZM + ZM installation consists of the equipment shown on this sheet (sheet ) plus additional equipment/wiring shown on the other sheets, some of which is optional and

More information

Simpson Digital Meters/Controllers

Simpson Digital Meters/Controllers Simpson igital Meters/ontrollers Includes new temperature measurement models (H340) ll Parameters Set from Front Panel 7 Segment 4-1 /2 or 3-1 /2 igit right Red isplay Screw Terminals for asy Installation

More information

Distribution/Substation Transformer

Distribution/Substation Transformer Distribution/Substation Transformer Type VFI, Vacuum Fault Interrupter Transformer Option Functional Specification Guide Functional specification for 15 kv, 25 kv, or 35 kv vacuum fault interrupter distribution/substation

More information

B240, 2-Way, Characterized Control Valve Stainless Steel Ball and Stem

B240, 2-Way, Characterized Control Valve Stainless Steel Ball and Stem 0, 2-ay, haracterized ontrol Valve Stainless Steel all and Stem pplication This valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating or cooling coils. Some

More information

High-Speed DC Circuit-Breakers for Fixed Installation Type UR26, UR36, UR40 & UR46

High-Speed DC Circuit-Breakers for Fixed Installation Type UR26, UR36, UR40 & UR46 O M P O N E N T S High-Speed D ircuit-reakers for Fixed Installation Type UR26, UR36, UR40 & UR46 The UR26, UR36, UR40 & UR46 are D high-speed current limiting air ircuit-reakers, trip free, single pole,

More information

Power System Protection Manual

Power System Protection Manual Power System Protection Manual Note: This manual is in the formative stage. Not all the experiments have been covered here though they are operational in the laboratory. When the full manual is ready,

More information

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime Issued: 5.06.999 Status: 5.06.999 Version: B/09..00 Data subject to change without notice Features Overvoltage and undervoltage protection Single- or three-phase operation High-set overvoltage stage with

More information

BEA MATRIX INDUCTION LOOP. BEA - LZR-i30 RD BK GRN/WH BLK/WH YDC2 WH/BU

BEA MATRIX INDUCTION LOOP. BEA - LZR-i30 RD BK GRN/WH BLK/WH YDC2 WH/BU R PART # WG NO SHEET 8 4 3 1 NEXT ASSEMBLY ISION HISTORY 802E012 ESRIPTION EN BY APPROVE A RENAMETERMINALS FOR BEA AN PHOT 88 /31/2012 BJJ BEA - Falcon, Eagle, MS08 * US 1-2- 3-WH * 4-GN not used -YE BEA

More information

SIA-C Dual & Self powered overcurrent & earth fault relay USER S MANUAL. EN_FANOXTD_MANU_SIA_Ocefsecondarydist_SIAC_R039.Docx

SIA-C Dual & Self powered overcurrent & earth fault relay USER S MANUAL. EN_FANOXTD_MANU_SIA_Ocefsecondarydist_SIAC_R039.Docx SIA- Dual & Self powered overcurrent & earth fault relay USER S MANUAL EN_FANOXTD_MANU_SIA_Ocefsecondarydist_SIA_R039.Docx 1. REEPTION, HANDLING, INSTALLATION... 6 1.1. Unpacking... 6 1.2. Reception of

More information

Protection components

Protection components Multifunction protection relays LT-P Environment Conforming to standards IEC 947-4-1, IEC 34-11, IEC 755, VDE 010, VDE 00. &Ãmarking Meets the essential requirements of the Low Voltage equipment (LV) &

More information