from 0.5 to 125 A Electrical characteristics Sensitivity type (ma) a AC Electrical auxiliaries Auxiliary and alarm switches (OF-SD)
|
|
- Hugo Theodore Hawkins
- 5 years ago
- Views:
Transcription
1 Acti 9 Acti 9 circuit reakers from 0.5 to 125 A N-32_SE.eps N-28_SE.eps PB104440_28.eps PB107141_28.eps Acti 9 circuit reaker C120N Numer of poles Electrical characteristics Rated current (A) In Rated insulation voltage (V) Ui 500 Impulse withstand voltage (kv) Uimp 6 Maximum operational voltage (V) Ue AC 50/60 Hz 440 Fast closing idpn N Suitaility for isolation and positive contact indication AC reaking capacity IEC (EN 60898) Icn (A) 230/400 V Ph Ph/Ph IEC (EN ) Icu (ka) V V V V 3 (1) / V V - - Ics (% of Icu) 75 % ic60n Trip units (non adjustale) Curve type B (lm = 3 to 5 ln) C (lm = 5 to 10 ln) D (lm = 10 to 14 ln) MA (lm = 12 ln) Add-on rcd s (Vigi module) Integrated - Sensitivity type (ma) a AC A k A si A si E C120 Electrical auxiliaries Auxiliary and alarm switches (OF-SD) Shunt trip (MX); undervoltage release (MN) Emergency stop opening switch (MNx) Voltage threshold release (MSU) Connection Cale maxi capacity (mm 2 ) Flexile 16 Rigid 25 Installation Plug in ase y 63 A Terminal shieds Padlocking device Rotary handle NG125N Dimensions (mm) W 27 per pole H 81 D 73 (1) Breaking capacity under 1 pole with IT isolated neutral system (case of doule fault). A-4
2 C120H NG125N NG125H NG125L NG125L MA Ph Ph/Ph Ph Ph/Ph Ph Ph/Ph Ph Ph/Ph Ph/Ph (1) % 75 % 75 % 75 % 75 % per pole A-5
3 PB103512_SE_40.eps NG160 3 and 4 pole circuit reakers and switch-disconnectors specially designed for use upstream of Multi 9 modular devices: reinforcement of reaking capacities of downstream devices y cascading up to 25 ka easy installation in Pragma or Prisma Plus type G enclosures: v standard 45 mm front cut-out v clip-on installation on a DIN rail v reduced depth (82.5 mm). NG160 circuit reaker. Characteristics of NG160 circuit reakers and switch-disconnectors Incomer for modular switchoards NG160 circuit reaker Electrical characteristics as per IEC Rated current (A) In 40 C 160 Rated insulation voltage (V) Ui 800 Rated impulse withstand voltage Uimp 8 (kv) Rated operational voltage (V) Ue AC 50/60 Hz 500 Type of circuit reaker E N H Ultimate reaking capacity Icu AC 220/240 V (ka rms) 50/60 380/415 V Hz 440 V V Service reaking capacity Ics % Icu 75 % Suitaility for isolation Duraility (C-O cycles) mechanical electrical (In -440 V) 5000 Protection Built-in thermal-magnetic trip unit Ratings In Thermal protection Ir fixed threshold Magnetic protection lm NG160NA switch-disconnector Electrical characteristics as per IEC Conventional thermal current (A) Ith 40 C 160 Rated insulation voltage (V) Ui 800 Rated impulse withstand voltage Uimp 8 (kv) Rated operational voltage (V) Ue AC 50/60 Hz 500 Rated operational current Ie AC 50/60 Hz AC22A AC23A 220/240 V /415 V /480 V V Short-circuit lcm (ka peak) 2.1 making capacity min. for switchdisconnector alone max. with protection 330 y upstream circuit reaker Short-time withstand current Icw (A rms) 1 s s 1500 Suitaility for isolation Coordination etween circuit reakers and switch-disconnectors The switch-disconnector must e protected against downstream short-circuits. The choice of the right switch-disconnector therefore depends on coordination with the protective device installed upstream. The tale elow indicates the maximum short-circuit current in karms for which the switch-disconnector is protected y coordination with the circuit reaker located upstream. Important: the switch-disconnector must e protected against overloads. The rating of the switch-disconnector must e greater than or equal to that of the upstream circuit reaker. Upstream protection NR100F NS100 - NS160 NR160F N SX H NG160NA downstream V Isc max ka rms Making capacity ka peak V Isc max ka rms Making capacity ka peak A-6
4 Protection Overview of the earth leakage protection product range Selection guide Type PB Residual current circuit reakers iid K iid RCCB-ID type B PB _SE-35 Standards IEC/EN IEC/EN IEC/EN and VDE 0664 Numer of poles 1P+N 2P 3P 4P Type AC A si(e) B Voltage (V) Ue 230/ / /400 Impulse voltage (kv) Uimp Insulation voltage (V) Ui Current rating (A) In to to 125 Frequency (Hz) 50/60 50/60 50 Rated reaking capacity (A) Icn Rated residual reaking and (IDm) 10 In (500 A min.) In (500 A min.) making capacity (A) Curve Sensitivity (ma) (IDn) s 500 s 1000 s 3000 s Electrical characteristics Curves B C D L K MA For more details, see page Page 102 Page 97 Page 104 Accessories Page 123 and 136 Page version: 1.1 Acti9 Catalogue 2011_12.indd
5 Protection Overview of the earth leakage protection product range (cont.) PB101616_SE-35 Add-on residual current devices Vigi ic60 PB Vigi C _SE-35 IEC/EN and IEC/EN and IEC/EN IEC/EN , 230/ / /60 50/60 Depending on circuit reaker used Depending on circuit reaker used Page 82 Page 88 Page 123 and 136 Page 123 and 136 Acti9 Catalogue 2011_12.indd version:
A9 R Range Family Code Internal code Poles Code Rating (A) Code Acti 9 (A9) iid R
Earth leakage protection Principle of catalogue numers A9 R 15 2 63 Range Family Code Internal code Poles Code Rating (A) Code Acti 9 (A9) iid R 0 0 0 00 Vigi ic60 V 1P 1 0.5 70 ic60 F 2P 2 0.75 71 ik60
More informationIntroduction Characteristics and performance of Compact NSX circuit breakers from 100 to 250 A up to 690 V
Functions and characteristics Introduction Characteristics and performance of Compact NSX circuit reakers from to A up to 69 V PB.eps PB6_.eps PB_.eps Compact NSX/6/. Compact NSX R. Compact NSX HB. ()
More informationisw switches Control Local control IEC/EN , isw switch with indicator light. IEC/EN , isw switch without indicator light.
isw switches DB88 PB0566-40 Position contact indication b Suitable for industrial isolation according to IEC/EN 60947-3 standard. b The presence of the green strip guarantees physical opening of the contacts
More informationPage 13-2 Page Page 13-7
Page -2 Page -6 MINIATURE CIRCUIT BREAKERS UP TO 63A 1P, 1P+N, 2P, 3P and 4P versions IEC rated current In: 1-63A IEC short-circuit capacity Icn: 10kA (6kA for 1P+N) Trip characteristic curve: Type B,
More information3 - Protection components Circuit-breakers
Contents - Protection components Circuit-breakers for the motor protection Selection guide..............................................page /2 Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationMaintenance/Connection/Installation Service life C/O cyclesx1000
EasyPact MVS 2016 CPB100000 CPB100014 Circuit breaker. Switch disconnector. Common characteristics Number of poles Rated insulation voltage (V) Impulse withstand voltage (kv) Rated operational voltage
More informationSINCE 1989 Quality Products, Prompt Services, Trustful Relationships www.kmindustrialcorp.com KM Industrial Corporation has estalished itself as a trusted supplier of Electrical, Machinery and Industry
More informationTechnical catalogue. Emax Low voltage air circuit-breakers. Hotline:
Technical catalogue Emax Low voltage air circuit-breakers www.alobitanbd.com Hotline: 01711548558 PAGE : 02 The new Emax have received innumerable international certifications and approval by the major
More informationSection five. Connection systems. Isobar 4 Evo MCB pan assemblies Mulitclip busbar and Polybloc 126. Comb busbars 127
Connection systems Section five Isobar 4 Evo MCB pan assemblies 122 1 Mulitclip busbar and Polybloc 126 Comb busbars 127 Terminals and installation accessories 128 129 121 Isobar 4 Evo MCB pan assemblies
More information(1,5 modules per pole)
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 25kA 80A to 125A CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationChoice of earth leakage protection devices
Protection Choice of earth leakage protection devices DB123167 DB123168 DB123169 Choice of sensitivity The sensitivity of an earth leakage protection device depends mainly on the function it has to perform:
More informationiprd, iprd IT surge arresters Type 2 or 3 LV withdrawable surge arresters
arresters iprd withdrawable surge arresters allow quick replacement of damaged cartridges. Type 2 surge arresters are tested with a 8/20 μs current wave. Type 3 surge arresters are tested with a 1.2/50
More informationMerlin Gerin Circuit breaker application guide
Reset Micrologic 70 Ir Isd Ig Ap reset I i I n 0 1 2 5 3 push OFF push ON O OFF discharged NX 32 H 2 Ue Icu 220/440 525 690 cat.b (V) (ka) Ics = 100% Icu IEC 947-2 EN 60947-2 100 100 85 Icw 85kA/1s 50/60Hz
More informationBtdin RCD Add-on modules 63A for MCBs 1,5 modules per pole
Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics... 4 6. Compliance - Approvals... 6 7. Curves... 7 8. Auxiliares and
More informationTeSys circuit-breakers Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7
Presentation Thermal-magnetic motor circuit-breakers types GV, GV and GV7 GV-ME, GV-P, GV-ME and GV7-R motor circuit-breakers are -pole thermal-magnetic circuit-breakers specifically designed for the control
More informationCircuit breakers for direct current applications
Circuit breakers for direct current applications Complementary technical information schneider-electric.com Complementary technical information Circuit breakers for direct current applications Contents
More informationAEG Low Voltage Component
AEG Low Voltage omponent Technology transfers reliable power We are striving to create a peaceful and comfortable life for you. AEG: We believe that power system can be very simple. Main distribution system
More informationMiniature Circuit Breakers B4/B6/B10, Residual Current Devices & Isolating Switches
Miniature ircuit reakers 4//, esidual urrent evices & Isolating Switches The IMO range of miniature circuit breakers have been designed for protection of electrical installations against overload and short
More informationSIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A
The solution for Load break switches > Power distribution. sircm_100_a_1_cat Rotary switch SIRCO M 3 x 100 A Strong points > Total integration. > Wide range of accessories. > Upgradeability. > Compliance
More informationMULTIBLOC 00.ST8 Size A, 690VAC Bottom Fitting, 1-,2-,4-pole
MULTIBLOC 00.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 00.ST8 comprises NH fuse switch disconnectors for 160A. They are designed for bottom
More information(With the possibility of a tripping coil for remote control) (Generally optional with an electronic tripping device)
Page 1 of 22 Personal tools Log in / create account Circuit-breaker From Electrical Installation Guide The circuit-breaker/disconnector fulfills all of the basic switchgear functions, while, by means of
More informationTHE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES P. 20-21 DX³ - MCB AC Application upto 63 A MCBs P. 23 DX³ - 25 ka MCB from 6 A to 125 A Isolator RCCB & RCBOs
More informationTechnical features table for miniature circuit-breakers SH 200 Series
Technical features table for miniature circuit-breakers SH 00 Series Standards Poles Tripping characteristics I n A frequency f Hz insulation voltage U i acc. to IEC/EN 60664-1 V Overvoltage category Pollution
More informationLow Voltage. Residual-current protection relays
Low Voltage Residual-current protection relays Class II insulated for the entire range as per standards IEC/EN 60664-1 and NFC 15-100. Front-panel mount DIN rail with clip-in toroid with mounting
More informationDPX TM MCCBs LP* Description Cat. nos. ` / Pack Unit
DPX TM MCCBs Description Cat. nos. ` / Pack DPX TM MCCBs Description Cat. nos. ` / Pack Auxiliary contact / Fault signalling contact DPX 125,160,250 ER 0261 60 804 1/24 250, 630, 1600, 1250 Under voltage
More informationComponents for Marine applications
Components for Marine applications Imagination GE imagination at work. at work v. 10-2015 GE Industrial Solutions Leading the future of electrification GE Industrial Solutions is leading the future of
More informationCircuit Breakers FAZ / FAZ6. Installation Products for Industrial Applications
Circuit Breakers FAZ / FAZ6 Installation Products for Industrial Applications Optimum and powerful protection for every application FAZ up to 15 ka IEC/EN 60947-2 up to 10 ka IEC/EN 60898 up to 10 ka UL
More informationC 1. SPECTRONIC SP - Air circuit breakers. Summary. C.3 General characteristics. C.4 Fixed circuit breaker. C.5 Withdrawable circuit breakers
SPETRONI SP - Air circuit breakers Summary.3 General characteristics.4 Fixed circuit breaker.5 Withdrawable circuit breakers.6 haracteristics.7 RMS 7: protection and control unit.10 RMS 9: protection and
More informationAdd-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 Add-on modules DX 3 63A for MCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4.
More informationMiniature circuit breakers. Residential current circuit breakers. Busbar systems. Comfort functions/energy control. Residential enclosures
.2..4.5.6.7 Technical data Series ME07 Standard range S, S, 0/690V/AC High performance range H, 0/690V/AC High performance range H/S, 000V/AC Disconnecting switch MET DC circuit breaker ME 6T up to 0V/DC
More informationMotor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A
DATASHEET - PKZM4-50 Delivery program Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection Part no. PKZM4-50 Catalog No. 222355 Eaton Catalog No. XTPR050DC1NL EL-Nummer 0004355161 (Norway)
More informationCompact NS630b to 1600
Compact NS630 to 1600 Fixed circuit reakers The diagram is shown with circuits de-energised, all devices open, connected and charged and relays in the nmal position. Power Control unit DB8378.eps Power
More informationTEST REPORT IEC Low-voltage switchgear and controlgear - Part 2: Circuit-breakers
Test Report issued under the responsibility of: TEST REORT Low-voltage switchgear and controlgear - art 2: Circuit-breakers Report Reference No.... : 3305316.50 Date of issue... : 2013-09-17 Total number
More information04 Page. MCCBs characteristics 94. MCCBs & accessories selection guide 96. MCCBs x MCCBs x MCCBs h
This section includes moulded case circuit breakers, manual and automatic transfer switches and load break switches which are utilised for the switching, protection and distribution of low voltage installations.
More informationCoordination of LV protection devices
Technical collection Coordination of LV protection devices Low voltage expert guides n 5 DBTP107EN_Couv.indd 1 12/06/2009 14:32:52 Sans titre-1 1 12/06/2009 14:13:13 Contents Glossary 2 The requirements
More informationNIRAPOD 1. High performance circuit breaker mcb and combined mcb with remote controls. LV Distribution Products 2-63A
High performance circuit breaker mcb and combined mcb with remote controls LV Distribution Products 2-63A Mini motorized circuit breaker The mini-series of motorized circuit breakers operates both locally
More informationModeion OTHER ACCESSORIES OF MOULDED CASE CIRCUIT BREAKERS
OTHER ACCESSORIES OF MOULDED CASE CIRCUIT BREAKERS P Other accessories DELAY UNIT Type Product code Description Weight [kg] Package [pc] BZ-BX-X230-A 36696 enables to delay the undervoltage release tripping
More informationDatasheet - PROTECT-IE-02
Print - Create PDF - Create EXCEL file 20.04.2011-18:28:57h Datasheet - PROTECT-IE-02 Input expander / PROTECT-IE Input expander Input for up to 4 sensors per interface e.g.: magnetic safety switches type
More informationtechnical information
technical information protection devices 192 circuit protection principle 194 circuit breakers characteristics 200 moulded case circuit breakers (MCCB) 205 prospective fault current 208 selectivity and
More informationBtdin RCD Add-on Modules 32A - 63A for M.C.Bs 1 module per pole
Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics.... 4-6 6. Compliance - Approvals... 6 7. Curves... 7 1 / 7 1. DESCRIPTION
More informationSIRCO M UL 98 Load break switches standards UL and CSA from 30 to 100 A
Load break switches standards UL and CSA The solution for Load break switches sircm_1_a_1_cat > Power distribution Strong points Function Rotary switch SRCO M 3 x 1 A SRCO M load break switches are compact
More informationitl impulse relays IEC/EN itls: IEC/EN itls b Allows remote indication of its operating state (open/closed)
DB123399 DB116619 Country approval pictograms itl, itli, itls, itlc, itlm IEC/EN 60669-2-2 itls: IEC/EN 60947-5-1 Impulse relays B106126-34 B106128-34 itl b The impulse relays are used to control, by means
More informationpage 2 of 86 Report reference No:
articulars: test item vs. test requirements 3. Classification 3.1. Utilization category: (A or B)... : A 3.2. Interruption medium: (air, vacuum, gas Break)... : Air 3.3. Design: (open construction, moulded
More informationMould circ. Moulded case circuit-breakers
Mould circ Moulded case circuit-breakers Moulded case circuit-breakers Tmax Contents Power distribution circuit-breakers Technical Data... 7/6 Ordering details Reading information... 7/15 Tmax T1... 7/20
More informationFuse Links NV/NH gg with Striker Pin Dimensions
D E I A 9,8 G J H l l Fuse Links Electrical characteristics Rated voltage U n Rated current I n reaking capacity U n Melting characteristic ertified In accordance with Dimensions according to Two versions
More informationJ7M-AM/-BM. Motor--protective circuit--breaker system. J7M -BM System IEC 947, EN IEC 947, EN 60947
Motor--protective circuit--breaker system J7M -AM System Rated operational current 25 A. Switching capacity up to 10 A, 100 ka/415 V. Switching capacity 16 A, 20 A, 25 A, 16 ka/415 V. Fixed short--circuit
More informationUTE100 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTE100 NT FMU 100A 3P LL LSIS UL MCCB
PRODUCT CATALOG SUSOL SUPER SOLUTION SELECTION GUIDE UTE00 CATALOG NUMBERING [PRODUCT SELECTION] UTE00 NT FMU 00A 3P LL UL SERIES & FRAME: Susol 00AF PERFORMANCE Rating 80% 00% ka SUFFIX UL : UL 20/ 240Vac
More informationType CP-S, CP-C & CP-A Switch mode
Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting
More informationCircuit breakers for direct current applications up to 380 V DC Choosing and implementing protective devices
Circuit breakers for direct current applications up to 380 V DC Choosing and implementing protective devices schneider-electric.com Green Premium TM Endorsing eco-friendly products in the industry Schneider
More informationModeion MOULDED CASE CIRCUIT BREAKERS BL1000S
G MOULDED CASE CIRCUIT BREAKERS BL1000S G BL1000S COMMERCIAL INFORMATION 3P Switching units, withdrawable device...g4 Overcurrent releases...g5 Signalling units...g5 Residual current monitor...h6 Current
More informationL O V A G. T E S T I N S T R U C T I O N I E C / E N E d C O N D I T I O N S F O R T E S T I N G
LTI IEC/EN 60947-4-1 Ed.3.1 L O V A G T E S T I N S T R U C T I O N I E C / E N 6 0 9 4 7-4 - 1 E d. 3. 1 C O N D I T I O N S F O R T E S T I N G C O N T A C T O R S A N D M O T O R - S T A R T E R S This
More informationCB Testing Laboratory...:EZÚ Address...:Pod Lisem Praha71-Trója Testing location/ procedure...: CBTL RMT SMT WMT TMP IEC60947_2C
age 1 of 109 Report No.600332-04/01 TEST REORT Low-voltage switchgear and controlgear art 2: Circuit - breakers Report Reference No....: 600332-04/01 Tested by (name+signature)...:... Witnessed by (name+signature)...:...
More informationModular equipment. Presentation, standards. Standard contactors TeSys GC
Presentation, standards Standard contactors TeSys GC Presentation TeSys GC contactors are designed for use in modular panels and enclosures. These contactors feature: b Easy installation v quick clip-on
More informationNS..S contactor relays - with spring terminals AC operated
NS..S contactor relays - with spring terminals AC operated NSES 1SBC101015F00 Description NS..S contactor relays are used for switching auxiliary and control circuits. These contactor relays are designed
More informationMCCBs and trip-free switches x160
MCCBs and trip-free switches x60 Moulded case circuit breakers x60 Available in 3P and 4P Mechanical test button, lockable settings, integrated padlocking handle Ø 4mm, Thermal magnetic trip unit, 2 versions:
More information90 ReStart AUTOMATIC RECLOSING DEVICES
RESTART WITH AUTOTEST Technical data TYPE ReStart with Autotest 2P ReStart with Autotest PRO 2P ReStart with Autotest PRO 4P Electrical characteristics Standards: EN 50557, EN 61008-1 Distribution system:
More informationTeSys H. Protection. Motor controllers. Reliable. Motor starters. Contactors. Circuit breakers. Smart. Ultra-compact 22.5 mm motor starters
Low voltage Catalogue 205/206 Ultra-compact 22.5 mm motor starters Motor starters Flexible Smart Circuit breakers Protection Contactors Thermal overload relays Fuse switchdisconnectors Reliable Motor controllers
More informationBtdin RCD Add-on Modules 32A - 63A for M.C.Bs 1 module per pole
Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics.... 4-6 6. Compliance - Approvals... 6 7. Curves... 7 1 / 7 1. DESCRIPTION
More informationFIB / FIC. r with Overcurrent Protection (RCBO) Doepke. » effi cient. » reliable. » fl exible. » future-oriented
Doepke The experts in residual current protection technology Residual Current Circuit-Breakers it- r with Overcurrent Protection (RCBO) FIB / FIC» effi cient» reliable» fl exible» future-oriented Doepke
More informationT e c h n i c a l C a t a l o g u e MCCB. Moulded Case Circuit Breaker
T e c h n i c a l C a t a l o g u e MCCB Moulded Case Circuit Breaker contents general overview... 2 feature - company profile and certifications... 6 MCCB - NF series circuit breaker, double repulsion
More informationABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 042 F0t08 CM-PVS.31 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage Threshold values for over- and undervoltage are adjustable
More informationMiniature circuit-breakers S 280 UC series. System pro M. Technical data
Technical data 11 Robbie Rd. / Avon, MA 02322 T:(508)513-1000 F:(508)513-1100 70 Ernest St. / Providence, RI 02905 T:(401)781-7100 www.controllerservice.com System pro M Prior to connection of aluminum
More informationInstallation / Monitoring Technique
Installation / Monitoring Technique VARIMETER RCM Residual Current Monitor, Type B for AC and DC Systems IP 5883 0249633 IP 5883 ND 5018/035 ND 5018/030 According to IEC/EN 62 020, VDE 0663 For AC and
More informationTechnical Data & Applications
Technical Data & Applications Dorman Smith Switchgear Limited With over 0 years of experience in switchgear design and production Dorman Smith Switchgear Limited continues to provide high quality equipment
More informationMULTIBLOC 4a.ST8 Size 4a, 690VAC, 1600A, 690VAC, Design for Bottom Fitting, 1-, 3-pole
MULTIBLOC 4a.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS Touch protection IP 20 Safe on load connection/disconnection in accordance with IEC 609473 The production
More informationTSX Series. Modicon Manuals. Presented by: Modicon PLC. Schneider Electric Quantum Modicon Gould Gettys
TSX Series Modicon Manuals Presented by: Modicon PLC Schneider Electric Quantum Modicon Gould Gettys For Product Needs: Email: sales@modiconplc.com Call: 1-800-691-8511 Fax: 919-415-1614 ModiconPLC.com
More informationCircuit protection devices
Circuit protection devices MCBs, RCCBs, RCBO, ELR, surge arresters, fuse carriers, complete range of auxiliaries, busbars and connectors EA 2002/1 Welcome to the new edition of our general catalogue For
More informationCI-tronic Analogue Power Controller ACI 30-1 and ACI 50-1
Technical Document CI-tronic Analogue Power Controller ACI 30-1 and ACI 50-1 Features Phase angle or burst firing control mode Current loop control, 4 20 ma, 20 4 ma, 0 20 ma and 20 0 ma Voltage control,
More informationResidual current circuit breakers (RCCBs)
Residual current circuit breakers (RCCBs) Description Automatically trips in event of earth leakage fault Provides protection against direct & indirect contact with live parts Technical data IS 12640-1,
More informationBreakcontact,Front. Articleno Deliveryprogramme. Product range RMQ-Titan (drilling dimensions 22.5 mm) Basic function Accessories
Breakcontact,Front Partno. M22-K01 Articleno. 216378 Deliveryprogramme Product range RMQ-Titan (drilling dimensions 22.5 mm) Basic function Accessories Standard/Approval UL/CSA, IEC Construction size NZM1/2/3/4
More informationTeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X
Characteristics Contactor type LC1 D09 D18 DT20 and DT25 Environment Rated insulation voltage (Ui) Conforming to IEC 097--1, overvoltage category III, degree of pollution: 3 Conforming to UL, CSA V 00
More informationCI-tronic Analogue Power Controller ACI 30-1 and ACI 50-1
MAKING MODERN LIVING POSSIBLE Technical brochure CI-tronic Analogue Power Controller ACI 30-1 and ACI 50-1 www.danfoss.com Contents Page Features... 3 Description... 3 Selection... 3 Technical data...
More informationNZMH4, NZM(H)6(B), NZM(H)9, NZM12 Technical Data
Circuit Breakers, 09/098 Molded case circuit breakers 3 pole NZMH 4-...-C 1) NZM6B.../ZM6A...- Frame size A 80 125 125 IEC 60 947-2 Electrical Ratings Rated impulse withstand voltage U imp V 8000 8000
More informationThree-phase monitoring relays
2CDC 251 046 F0t08 Features Monitoring of three-phase mains for phase sequence, phase failure, phase unbalance Threshold value for phase unbalance adjustable as absolute value Tripping delay can be adjusted
More informationCapacitor Switching Contactors
Capacitor Switching D385E51 Technical catalogues and news under: www.benedict.at Motor-Starter Mini- Overload Relays Capacitor Switching Motor-Starters Modular Circuit Breakers M4-32T... up to 32A M4-32R..
More informationEarth leakage protection Response time of medium-sensitivity residual current devices
Response time of ic60 Vigi and iid60 The medium-sensitivity (100 1000 ma) in the Acti9 range conform to IEC/EN 61008 and 61009: bbtheir response time guarantees personal protection against indirect contacts
More informationUse RH covers when starting with a LH feed unit or when reaching the LH board. HIGH RATING
Aluminium 1000A 1250A 1600A 2000A 2250A 2500A 3200A 4000A 4500A R 95503111 95503131 95503131 95503141 95513111 95513131 95513131 95513141 95513151 L 95503211 95503231 95503231 95503241 95513211 95513231
More informations s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz
HPL11002EN DILETTiming relays Rated operational current AC-11 230 V 400 V I th I e I e A A A A A Conventional thermal current Time Range Voltage Article No. See price list Std. pack On-delayed Timing functions
More informationABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.
2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 2CDC 251 050 F0t08 CM-MPS.31 2CDC 251 051 F0t08 CM-MPS.41 R/T: yellow LED - relay status, timing F1: red LED - fault message F2: red LED - fault
More information27/04/2015
Modular Carril DIN 35 mm HIL Part number 84871120 Control of AC and DC currents Automatic recognition of AC/DC Measurement ranges from 2 ma to 10 A Choice between over and undercurrent True RMS measurement
More informationLC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationV2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC
P AC/DC voltage monitoring Multifunction Supply voltage 24 V DC or 230V AC/DC Supply circuit = Measuring circuit 1 change-over contact Width 22,5 mm Control elements Tripping delay Maximum threshold Minimum
More informationCM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC
2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage as well as phase unbalance
More informationPhase control Single function phase control relay - 7.5 mm Control of -phase networks: phase sequence, total phase failure Multi-voltage from x 08 to x 480 V Controls its own supply voltage True RMS measurement
More informationMicro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13
Micro Contactor Relays 10 Micro Contactors 11 Micro Contactors With Solder Pins 12 Coil voltages 12 Micro Reversing Contactor 13 Technical Data 14 Dimensions 18 D946E 9 Micro Contactor Relays 4-pole AC
More informationProtection components
General Application LT3-Si thermistor protection units continuously monitor the temperature of the machines to be protected (motors, generators, etc.) by means of PTC thermistor probes embedded in the
More informationABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.
2CDC 251 054 F0t08 CM-MPN.52 2CDC 251 055 F0t08 CM-MPN.62 2CDC 251 056 F0t08 CM-MPN.72 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage
More informationResidual Current-operated Circuit Breakers (RCCBs) F 360 and F 370 Range
Technical data System pro M Residual Current-operated Circuit Breakers (RCCBs) System pro M 1 When connecting aluminium conductors ensure that the contact surfaces of the conductors are cleaned, brushed
More information7P Series - Surge Protection Device (SPD) Features 7P P P
Features 7P.09.1.255.0100 7P.01.8.260.1025 7P.02.8.260.1025 SPD Type 1+2 Surge arrester range - single phase system / three phase system Surge arresters suitable in low-voltage applications in order to
More informationControl module CP-A CM
2CDC 271 002 F0t05 Features Pluggable onto redundancy unit CP A RU Threshold values adjustable (14 28 V) One relay output per monitored input / channel Approvals H UL 508, CAN/CSA C22.2 No.14 H UL 60950,
More informationThree-phase monitoring relay
1SR 550 870 F9400 Features Monitoring of three-phase mains for phase failure, over- and undervoltage Device with possibility of neutral monitoring available Device with suitability for monitoring single-phase
More informationMeasuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC
2CDC 251 244 F0t05 Characteristics Monitoring of DC and AC currents: RMS measuring principle One device includes 3 measuring ranges Over- or undercurrent monitoring configurable Hysteresis adjustable from
More informationContent. Monitoring relay pluggable. 1-phase current monitoring relay phase direct-current voltage monitoring relay... 5.
Content Monitoring relay pluggable 1-phase current monitoring relay... 5.2 1-phase direct-current voltage monitoring relay... 5.6 1-phase voltage monitoring relay... 5.10 3-phase voltage monitoring relay...
More informationSemiconductor (AC) fuses
Main characteristics Recognized 650 to 300VAC / 63 to 2800A. Exceptionally low I 2 T, Watt losses. Non-magnetic construction, highly reliable low voltage. Indicator system. Conformity to UL, CSA investigated,
More informationMini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks
Mini Contactors Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 10 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 12 Mini Contactors
More informationFault indicator. Application. SPEF 3A2 C 1MRS MBG Issued: April 1999 Status: Updated Version: B/ Data subject to change without notice
Issued: April 1999 Status: Updated Version: B/08.11.200 Data subject to change without notice Features Versatile, multifunction line fault indicator for distribution networks Overcurrent, earth-fault and
More informationSwitchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated
Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated Medium-Voltage Switchgear Catalog HA 40.2 2009 Answers for energy. -HA40-111.eps -HA40-110.eps -HA40-109.eps -HA40-112.eps
More informationREX12 Electronic Circuit Protector
Description The compact and flexible all-in-one solution REX consists of several perfectly matched components. It comprises the EM12-T supply module for the plus and minus potential via a single or double
More informationLC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition
Product datasheet Characteristics Main Range Product name Product or component type Device short name Contactor application Utilisation category Device presentation Poles description Pole contact composition
More information