Technical features table for miniature circuit-breakers SH 200 Series
|
|
- Lambert Goodwin
- 5 years ago
- Views:
Transcription
1 Technical features table for miniature circuit-breakers SH 00 Series Standards Poles Tripping characteristics I n A frequency f Hz insulation voltage U i acc. to IEC/EN V Overvoltage category Pollution degree Data acc. to IEC/EN operational voltage U n V Max. power frequency recovery voltage (U max ) V Min. operating voltage V short-circuit capacity I cn ka Energy limiting class (B, C up to 40 A) impulse withstand voltage U imp. (1./50μs) kv Dielectric test voltage kv Reference temperature for tripping characteristics C Electrical endurance ops. Mechanical Data Housing Toggle Contact position indication Protection degree acc. to EN 6059 Mechanical endurance ops. Shock resistance acc. to IEC/EN Vibration resistance acc. to IEC/EN Environmental conditions (damp heat cyclic) acc. to IEC/EN C/RH Ambient temperature C Storage temperature C Installation Terminal Cross-section of conductors (top / bottom) mm Torque Screwdriver Mounting Mounting position Supply Dimensions and weight Mounting dimensions acc. to DIN Pole dimensions (H x D x W) Pole weight Combination with aux. elements Accessories mountable Nm mm g * Also fulfilling the requirement acc. to the protection degree IPXXB /8 CSC D00 Compact Home
2 CSC400030F007 CSC400030F0015 CSC400030F000 SH 00 SH 00 L SH 00 T IEC/EN P, P, 3P, 4P, 1P+N, 3P+N B, C 6 40 A 50 / 60 Hz 50 V AC (phase to ground), 440 V AC (phase to phase) III 1P: 30/400 V AC; 1P+N: 30 V AC;...4P: 400 V AC; 3P+N: 400 V AC 1P: 53 V AC; 1P+N: 53 V AC;...4P: 440 V AC; 3P+N: 440 V AC 1 V AC 6 ka 4.5 ka 3 ka 3 4 kv (test voltage 6.kV at sea level, 5kV at,000m) kv (50 / 60Hz, 1 min.) B, C: 30 C I n < 3A: 0,000 ops (AC), I n 3A: 10,000 ops. (AC); 1,000 ops. (DC); 1 cycle (s - ON, 13s - OFF, I n 3A), 1 cycle (s - ON, 8s - OFF, I n > 3A) Insulation group II, RAL 7035 Insulation group II, black, sealable Marking on toggle (I ON / 0 OFF) IP0*, IP40 in enclosure with cover 0,000 ops. 5 g - 3 shocks - 11 ms 5g - 0 cycles at Hz with load 0.8 I n 8 cycles with 55 C/90-96% and 5 C/95-100% C C Cage Terminal 5 mm / 5 mm.0 Nm No. Pozidrive On DIN rail 35 mm acc. to EN by fast clip any optional Mounting dimension 1 85 x 69 x 17.5 mm ca. 115 g No Compact Home CSC D00 /9
3 Ordering Information MCB SH 00 L Series - B characteristic N. of poles N module Bbn Order details Weight 1 piece Pack unit CSC400030F0015 SH01L-B SH01L-B NA SH0L-B SH03L-B CSC400030F0016 CSC400030F0017 CSC400030F0018 In A [17,5 mm] EAN Type code Order code Price Kg SH01L-B6 CDS41001R SH01L-B10 CDS41001R SH01L-B13 CDS41001R SH01L-B16 CDS41001R SH01L-B0 CDS41001R SH01L-B5 CDS41001R SH01L-B3 CDS41001R SH01L-B40 CDS41001R N SH01L-B6NA CDS41103R SH01L-B10NA CDS41103R SH01L-B13NA CDS41103R SH01L-B16NA CDS41103R SH01L-B0NA CDS41103R SH01L-B5NA CDS41103R SH01L-B3NA CDS41103R SH01L-B40NA CDS41103R SH0L-B6 CDS4001R SH0L-B10 CDS4001R SH0L-B13 CDS4001R SH0L-B16 CDS4001R SH0L-B0 CDS4001R SH0L-B5 CDS4001R SH0L-B3 CDS4001R SH0L-B40 CDS4001R SH03L-B6 CDS43001R SH03L-B10 CDS43001R SH03L-B13 CDS43001R SH03L-B16 CDS43001R SH03L-B0 CDS43001R SH03L-B5 CDS43001R SH03L-B3 CDS43001R SH03L-B40 CDS43001R /14 CSC D00 Compact Home
4 N. of poles N module Bbn Order details Weight 1 piece Pack unit SH03L-B NA SH04L-B CSC400030F0019 CSC400030F000 In A [17,5 mm] EAN Type code Order code Price Kg 3+N SH03L-B6NA CDS43103R SH03L-B10NA CDS43103R SH03L-B13NA CDS43103R SH03L-B16NA CDS43103R SH03L-B0NA CDS43103R SH03L-B5NA CDS43103R SH03L-B3NA CDS43103R SH03L-B40NA CDS43103R SH04L-B6 CDS44001R SH04L-B10 CDS44001R SH04L-B13 CDS44001R SH04L-B16 CDS44001R SH04L-B0 CDS44001R SH04L-B5 CDS44001R SH04L-B3 CDS44001R SH04L-B40 CDS44001R Compact Home CSC D00 /15
5 Ordering Information MCB SH 00 L Series - C characteristic N. of poles N module Bbn Order details Weight 1 piece Pack unit CSC400030F001 SH01L-C SH01L-C NA SH0L-C SH03L-C CSC400030F00 CSC400030F003 CSC400030F004 In A [17,5 mm] EAN Type code Order code Price Kg SH01L-C6 CDS41001R SH01L-C8 CDS41001R SH01L-C10 CDS41001R SH01L-C13 CDS41001R SH01L-C16 CDS41001R SH01L-C0 CDS41001R SH01L-C5 CDS41001R SH01L-C3 CDS41001R SH01L-C40 CDS41001R N SH01L-C6NA CDS41103R SH01L-C8NA CDS41103R SH01L-C10NA CDS41103R SH01L-C13NA CDS41103R SH01L-C16NA CDS41103R SH01L-C0NA CDS41103R SH01L-C5NA CDS41103R SH01L-C3NA CDS41103R SH01L-C40NA CDS41103R SH0L-C6 CDS4001R SH0L-C8 CDS4001R SH0L-C10 CDS4001R SH0L-C13 CDS4001R SH0L-C16 CDS4001R SH0L-C0 CDS4001R SH0L-C5 CDS4001R SH0L-C3 CDS4001R SH0L-C40 CDS4001R SH03L-C6 CDS43001R SH03L-C8 CDS43001R SH03L-C10 CDS43001R SH03L-C13 CDS43001R SH03L-C16 CDS43001R SH03L-C0 CDS43001R SH03L-C5 CDS43001R SH03L-C3 CDS43001R SH03L-C40 CDS43001R /16 CSC D00 Compact Home
6 N. of poles N module Bbn Order details Weight 1 piece Pack unit SH03L-C NA SH04L-C CSC400030F005 CSC400030F006 In A [17,5 mm] EAN Type code Order code Price Kg 3+N SH03L-C6NA CDS43103R SH03L-C8NA CDS43103R SH03L-C10NA CDS43103R SH03L-C13NA CDS43103R SH03L-C16NA CDS43103R SH03L-C0NA CDS43103R SH03L-C5NA CDS43103R SH03L-C3NA CDS43103R SH03L-C40NA CDS43103R SH04L-C6 CDS44001R SH04L-C8 CDS44001R SH04L-C10 CDS44001R SH04L-C13 CDS44001R SH04L-C16 CDS44001R SH04L-C0 CDS44001R SH04L-C5 CDS44001R SH04L-C3 CDS44001R SH04L-C40 CDS44001R Compact Home CSC D00 /17
7 Ordering Information MCB SH 00 Series - B characteristic N. of poles N module Bbn Order details Weight 1 piece Pack unit SH01-B SH01-B NA SH0-B SH03-B CSC400030F007 CSC400030F008 CSC400030F009 CSC400030F0030 In A [17,5 mm] EAN Type code Order code Price Kg SH01-B6 CDS11001R SH01-B10 CDS11001R SH01-B13 CDS11001R SH01-B16 CDS11001R SH01-B0 CDS11001R SH01-B5 CDS11001R SH01-B3 CDS11001R SH01-B40 CDS11001R N SH01-B6NA CDS11103R SH01-B10NA CDS11103R SH01-B13NA CDS11103R SH01-B16NA CDS11103R SH01-B0NA CDS11103R SH01-B5NA CDS11103R SH01-B3NA CDS11103R SH01-B40NA CDS11103R SH0-B6 CDS1001R SH0-B10 CDS1001R SH0-B13 CDS1001R SH0-B16 CDS1001R SH0-B0 CDS1001R SH0-B5 CDS1001R SH0-B3 CDS1001R SH0-B40 CDS1001R SH03-B6 CDS13001R SH03-B10 CDS13001R SH03-B13 CDS13001R SH03-B16 CDS13001R SH03-B0 CDS13001R SH03-B5 CDS13001R SH03-B3 CDS13001R SH03-B40 CDS13001R /18 CSC D00 Compact Home
8 N. of poles N module Bbn Order details Weight 1 piece Pack unit SH03-B NA SH04-B CSC400030F0031 CSC400030F003 In A [17,5 mm] EAN Type code Order code Price Kg 3+N SH03-B6NA CDS13103R SH03-B10NA CDS13103R SH03-B13NA CDS13103R SH03-B16NA CDS13103R SH03-B0NA CDS13103R SH03-B5NA CDS13103R SH03-B3NA CDS13103R SH03-B40NA CDS13103R SH04-B6 CDS14001R SH04-B10 CDS14001R SH04-B13 CDS14001R SH04-B16 CDS14001R SH04-B0 CDS14001R SH04-B5 CDS14001R SH04-B3 CDS14001R SH04-B40 CDS14001R Compact Home CSC D00 /19
9 Ordering Information MCB SH 00 Series - C characteristic N. of poles N module Bbn Order details Weight 1 piece Pack unit SH01-C SH01-C NA SH0-C SH03-C CSC400030F0033 CSC400030F0034 CSC400030F0035 CSC400030F0036 In A [17,5 mm] EAN Type code Order code Price Kg SH01-C6 CDS11001R SH01-C8 CDS11001R SH01-C10 CDS11001R SH01-C13 CDS11001R SH01-C16 CDS11001R SH01-C0 CDS11001R SH01-C5 CDS11001R SH01-C3 CDS11001R SH01-C40 CDS11001R N SH01-C6NA CDS11103R SH01-C8NA CDS11103R SH01-C10NA CDS11103R SH01-C13NA CDS11103R SH01-C16NA CDS11103R SH01-C0NA CDS11103R SH01-C5NA CDS11103R SH01-C3NA CDS11103R SH01-C40NA CDS11103R SH0-C6 CDS1001R SH0-C8 CDS1001R SH0-C10 CDS1001R SH0-C13 CDS1001R SH0-C16 CDS1001R SH0-C0 CDS1001R SH0-C5 CDS1001R SH0-C3 CDS1001R SH0-C40 CDS1001R SH03-C6 CDS13001R SH03-C8 CDS13001R SH03-C10 CDS13001R SH03-C13 CDS13001R SH03-C16 CDS13001R SH03-C0 CDS13001R SH03-C5 CDS13001R SH03-C3 CDS13001R SH03-C40 CDS13001R /0 CSC D00 Compact Home
10 N. of poles N module Bbn Order details Weight 1 piece Pack unit SH03-C NA SH04-C CSC400030F0037 CSC400030F0038 In A [17,5 mm] EAN Type code Order code Price Kg 3+N SH03-C6NA CDS13103R SH03-C8NA CDS13103R SH03-C10NA CDS13103R SH03-C13NA CDS13103R SH03-C16NA CDS13103R SH03-C0NA CDS13103R SH03-C5NA CDS13103R SH03-C3NA CDS13103R SH03-C40NA CDS13103R SH04-C6 CDS14001R SH04-C8 CDS14001R SH04-C10 CDS14001R SH04-C13 CDS14001R SH04-C16 CDS14001R SH04-C0 CDS14001R SH04-C5 CDS14001R SH04-C3 CDS14001R SH04-C40 CDS14001R Compact Home CSC D00 /1
11 Technical details Tripping diagrams B characteristic 10 C characteristic tripping curve from cold state 0 tripping curve from cold state Minutes Minutes Tripping time Tripping time Seconds Seconds Multiple of rated Multiple of rated acc. to IEC/EN I n = A SH 00T / SH 00 L / SH 00 acc. to IEC/EN I n = A SH 00T / SH 00 L / SH 00 / CSC D00 Compact Home
12 Internal resistances and power losses of the Miniature Circuit-Breakers Range SH 00 T B, C Range SH 00 L B, C Range SH 00 B, C A m Ω W m Ω W m Ω W Internal resistances per pole in m Ω Power losses per pole in W Internal resistances are subject to application-specific and environment-specific conditions and are therefore to be considered as typical values. Tripping characteristics acc. to IEC/EN Tripping characterisitic Thermal tripping 1 Electromagnetic tripping Test s: Tripping-time Test s: Tripping-time conventional non-tripping I 1 conventional tripping I conventional non-tripping conventional tripping > 1 h 0.1 s 45 s 3 A / 0.1 s 90 s 3 A B 1.13 I n 1.45 I n 3 I < 1 h 3 n 5 I n < 0,1 s > 1 h 0.1 s 15 s 3 A / 0.1 s 30 s 3 A C 1.13 I n 1.45 I n 5 I < 1 h 3 n 10 I n < 0,1 s 1) Influence of ambient temperature see below. ) Electromagnetic tripping valid for AC Hz. 3) From warm operating condition (immediately after I 1 >1h). Influence of ambient temperature The thermal releases are calibrated to a nominal reference temperature of 30 C for B and C characteristic. In the case of ambient temperatures deviating from these values the trip values: - are reduced in case of higher temperatures; - are increased in case of lower temperatures. The electromagnetic tripping is independent of the ambient temperature. Compact Home CSC D00 /3
13 Technical details Current-carrying capacity of the MCBs as a function of the ambient temperature Max. operating depending on the ambient temperature of a circuit-breaker in load circuit of characteristics type B and C. B, C Ambient temperature T ( C) In (A) Mutual thermal influence in the case of simultaneous load MCBs mounted in a row side by side MCBs mounted with a seperating distance X Current-carrying factor K n (= I/I n ) K N = max. -carrying factor with N units Diagram Current-carrying factor K X (= I/I n ) Diagram K X = max. -carrying factor with a separation of X mm X No. of units N separation distance X / mm Characteristic from diagram Calculation Example and characteristics of MCB Continuous load Number of MCB s / Mounting distance Continuous load > 1 h Continuous load, N MCB, Distance 0 Continuous load, N MCB, Distance X 1 I n / B, C ϑ R N / X I = I n K ϑ I = K ϑ K N I = K ϑ K X 16 A B 40 C 8 pieces / 0 and 8 mm In=16A incl. derating due to temp. 40 C: In=15.1A = 1.3 A 15.1A*0.77=11.6A 15.1A*0.98=14.8A /4 CSC D00 Compact Home
14 Max. Back-up protection SH 00 T / SH 00 L / SH 00 B/C Max. Back-up protection fuse Main Circuit Breaker S 700 6/8 63 A 100 A A 100 A A 100 A Maximum permissible earth-fault loop impedance Z s Impedance Z s at U 0 = 30 V AC 1 to ensure compliance with the operation conditions in accordance to IEC Operating time < 0.4 s; at 400 V AC < 0. s and at > 400 V AC < 0.1 s The instantaneous tripping of the MCB ensures an operating time of 0.1 s (TN system). Determined according to DIN VDE , supplement, (source impedance = 300 Ω, c = 0.95 and conductor temperature 70 C = factor 0.8). The internal resistance of the MCB is already included. SH 00, SH 00 L, SH 00 T I n A B max. Z s Ω C max. Z s Ω 1) U 0 = rated voltage against earthed conductor; for U 0 = 40 V~ is Z s 1.04; for U 0 = 17 V~ is Z s Take into account the voltage drop: e.g. in the case of a 1.5 mm conductor, protected by a B 16 circuit breaker, the maximum cable length is 8 m. If the voltage is below 3%, this would result in a maximum cable length ( wire) of 17 m. For more details on this topic, get your own copy of the technical information leaflet Maximum cable lengths. Maximum cable length in case of different voltages and cross sections on request. Compact Home CSC D00 /5
15 Technical details Short circuit selectivity In the case of a short circuit, selectivity exists up to the values indicated. MCBs short circuit discrimination in ka to main circuit breaker S 700 to fuse gl/gg (IEC ) series I n (A) SH 00 T B, C ** no selectivity SH 00 L B, C ** no selectivity SH 00 B, C ** no selectivity ** Limited or no selectivity at all possible in the overload range (thermal tripping) /6 CSC D00 Compact Home
16 Overall dimensions SH 00, SH 00 L, SH 00 T module modules 3 modules 4 modules Compact Home CSC D00 /7
Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 Add-on modules DX 3 63A for MCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4.
More informationBtdin RCD Add-on modules 63A for MCBs 1,5 modules per pole
Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics... 4 6. Compliance - Approvals... 6 7. Curves... 7 8. Auxiliares and
More informationContactors and Contactor Assemblies
s for Switching Motors Technical data General data Permissible mounting position The contactors are designed for operation on a vertical mounting surface. C and DC operation S3 3RT14 46 For DC operation
More informationModular equipment. Presentation, standards. Standard contactors TeSys GC
Presentation, standards Standard contactors TeSys GC Presentation TeSys GC contactors are designed for use in modular panels and enclosures. These contactors feature: b Easy installation v quick clip-on
More informationMiniature circuit-breakers S 280 UC series. System pro M. Technical data
Technical data 11 Robbie Rd. / Avon, MA 02322 T:(508)513-1000 F:(508)513-1100 70 Ernest St. / Providence, RI 02905 T:(401)781-7100 www.controllerservice.com System pro M Prior to connection of aluminum
More informationType CP-S, CP-C & CP-A Switch mode
Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting
More information(1,5 modules per pole)
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 25kA 80A to 125A CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationCurrent monitoring relays CM-SRS.2 for single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.2 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
More informationCurrent monitoring relays CM-SRS.2 For single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.2 For single-phase AC/DC currents The CM-SRS.2 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent
More informationElectronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet
CDC 0 F0t07 Features Rated control supply voltage -8 V DC, -0 V AC Single-function timer with star-delta change-over One device includes 7 time ranges (0.0 s - 0 min) n/o contacts LEDs for status indication
More informationMotor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A
DATASHEET - PKZM4-50 Delivery program Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection Part no. PKZM4-50 Catalog No. 222355 Eaton Catalog No. XTPR050DC1NL EL-Nummer 0004355161 (Norway)
More informationThermistor motor protection relays
Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /
More informationFor non-electrical quantities
Controlgear 3UG3 monitoring relays 3RS17 interface converters N nsb0346h nsb0348h nsb0775h For electrical quantities For non-electrical quantities 3RS17 interface converter Selection and ordering data
More informationElectronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with true OFF-delay and 10 time ranges. All electronic timers from
More informationElectronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with OFF-delay and 10 time ranges. All electronic timers from the CT-S
More informationVoltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages The CM-EFS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationThree-phase monitoring relay CM-PFS
Data sheet Three-phase monitoring relay CM-PFS The CM-PFS is a three-phase monitoring relay that is used to monitor three phase mains for incorrect phase sequence and phase failure. All devices are available
More informationVoltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationCoupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC
Data sheet Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC The CM-IVN serves to extend the measuring range of the insulation
More informationProtection and safety SQZ3 phase and sequence relay
SQZ3 phase and sequence relay Supply voltage [Vn] 400 V a.c. Frequency [Hz] 0/60 SQZ3 2CSC4001F0201 Contact type [A] 1 CO, 20 V, 10 A (cos =1) safety switching Minimum voltage adjustment trimmer [%] 100
More informationElectronic timer CT-SDD.22
CDC 099 F0t0 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied W
More informationElectronic timer CT-SDS.22
CDC 0 F0t07 Features Rated control supply voltage 8 V DC, 0 V AC Single function timer with star delta change over One device includes 7 time ranges (0.0 s 0 min) n/o contacts LEDs for status indication
More informationCurrent monitoring relays CM-SRS.1 for single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.1 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
More informationBtdin RCD Add-on Modules 32A - 63A for M.C.Bs 1 module per pole
Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics.... 4-6 6. Compliance - Approvals... 6 7. Curves... 7 1 / 7 1. DESCRIPTION
More informationCurrent monitoring relays CM-SRS.1 For single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.1 For single-phase AC/DC currents The CM-SRS.1 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent
More informationVoltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages For the monitoring of voltages in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
More informationElectronic timer CT-TGD.22
2CDC 251 097 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection
More informationDatasheet - PROTECT-IE-02
Print - Create PDF - Create EXCEL file 20.04.2011-18:28:57h Datasheet - PROTECT-IE-02 Input expander / PROTECT-IE Input expander Input for up to 4 sensors per interface e.g.: magnetic safety switches type
More informationElectronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts The CT-MXS.22 is a multifunctional electronic timer from the CT-S range. It provides 5 timing functions, 2 times 10 time
More informationTeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X
Characteristics Contactor type LC1 D09 D18 DT20 and DT25 Environment Rated insulation voltage (Ui) Conforming to IEC 097--1, overvoltage category III, degree of pollution: 3 Conforming to UL, CSA V 00
More informationIndustrial Miniature Circuit-Breakers S 220 series
Technical Data System pro M Industrial Miniature Circuit-Breakers System pro M 1 When connecting aluminum conductors, ensure that the contact surfaces of the conductors are cleaned, brushed and greased.
More informationResidual Current-operated Circuit Breakers (RCCBs) F 360 and F 370 Range
Technical data System pro M Residual Current-operated Circuit Breakers (RCCBs) System pro M 1 When connecting aluminium conductors ensure that the contact surfaces of the conductors are cleaned, brushed
More informationThermistor motor protection relays
Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /
More informationTemperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
More informationThree-phase monitoring relays
2CDC 251 046 F0t08 Features Monitoring of three-phase mains for phase sequence, phase failure, phase unbalance Threshold value for phase unbalance adjustable as absolute value Tripping delay can be adjusted
More informationPower supply CP-T 24/20.0 Primary switch mode power supply
Data sheet Power supply CP-T 24/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationCurrent monitoring relays CM-SRS.M1 For single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents The CM-SRS.M1 is an electronic current monitoring relay that monitors single-phase mains (DC or AC) for over- and undercurrent
More informationABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 042 F0t08 CM-PVS.31 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage Threshold values for over- and undervoltage are adjustable
More informationPower supply CP-T 24/10.0 Primary switch mode power supply
Data sheet Power supply CP-T 24/10.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationProtection components
General Application LT3-Si thermistor protection units continuously monitor the temperature of the machines to be protected (motors, generators, etc.) by means of PTC thermistor probes embedded in the
More informationPage 13-2 Page Page 13-7
Page -2 Page -6 MINIATURE CIRCUIT BREAKERS UP TO 63A 1P, 1P+N, 2P, 3P and 4P versions IEC rated current In: 1-63A IEC short-circuit capacity Icn: 10kA (6kA for 1P+N) Trip characteristic curve: Type B,
More informationCM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC
2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage as well as phase unbalance
More informationType: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information
Type: DILM80(110V50HZ,120V60HZ) Article No.: 239399 Sales text Contactor,37kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400
More informationBtdin RCD Add-on Modules 32A - 63A for M.C.Bs 1 module per pole
Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics.... 4-6 6. Compliance - Approvals... 6 7. Curves... 7 1 / 7 1. DESCRIPTION
More informationType: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information
Type: DILM95(230V50HZ,240V60HZ) Article No.: 239480 Sales text Contactor,45kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400
More informationElectronic timer CT-MFS.21
2CDC 251 053 F0t07 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c Rotary switch for the preselection of the
More informationType: DILM40(RDC24) Article No.:
Type: DILM40(RDC24) Article No.: 277780 Ordering information Rated operational current AC 3 400 V I e A 40 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50
More informationCoupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC
Data sheet Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC The CM-IVN serves to extend the measuring range of the insulation
More informationElectronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact The CT-MVS.12 is a multifunctional electronic timer from the CT-S range and provides 10 timing functions and 10 time ranges.
More information27/04/2015
Modular Carril DIN 35 mm HIL Part number 84871120 Control of AC and DC currents Automatic recognition of AC/DC Measurement ranges from 2 ma to 10 A Choice between over and undercurrent True RMS measurement
More informationMeasuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC
2CDC 251 244 F0t05 Characteristics Monitoring of DC and AC currents: RMS measuring principle One device includes 3 measuring ranges Over- or undercurrent monitoring configurable Hysteresis adjustable from
More informationV2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC
P AC/DC voltage monitoring Multifunction Supply voltage 24 V DC or 230V AC/DC Supply circuit = Measuring circuit 1 change-over contact Width 22,5 mm Control elements Tripping delay Maximum threshold Minimum
More informationMoeller Electric Corporation
EMR4-I Current Monitoring Relays 02/0053 EMR4-I1-2-A EMR4-I15-2-A EMR4-I15-2-B Mechanical lifespan operations x10 6 30 30 30 24-h cycle, 55 C, 93 % relative humidty, 96 h Ambient temperature min./max.
More informationCP-T range Product group picture
Product group picture /1 ABB Catalog Electronic Products and Relays 1/1 2CDC 110 00 C09 Table of contents CP-T range Product group picture /1 Table of contents /2 Benefits and advantages / Ordering details
More informationElectronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact The CT-TGD.12 is an electronic time relay with the function pulse generator. It is from the CT-D range. With their MDRC profile
More informationABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.
2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 2CDC 251 050 F0t08 CM-MPS.31 2CDC 251 051 F0t08 CM-MPS.41 R/T: yellow LED - relay status, timing F1: red LED - fault message F2: red LED - fault
More informationPower supply CP-T 24/40.0 Primary switch mode power supply
Data sheet Power supply CP-T 24/40.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationCharacteristics 5 TeSys k contactors and reversing contactors
90 Characteristics contactors k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 424 Product certifications LCp and LPp K06 to
More informationThree-phase monitoring relays CM-PVS.81
Data sheet Three-phase monitoring relays CM-PVS.81 The three-phase monitoring relay CM-PVS.81 monitors the phase parameters phase sequence, phase failure as well as over- and undervoltage. The device is
More informationDATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection
DATASHEET - ETR4-70-A Delivery program Timing relay, 2W, 0.05s-100h, multi-function, 24-240VAC/DC, potentiometer connection Part no. ETR4-70-A Catalog No. 031888 Eaton Catalog No. XTTR6A100H70B EL-Nummer
More informationThree-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41
Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.
More informationInsulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC
Data sheet Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC The CM-IWS.1 serves to monitor insulation resistance in accordance with IEC
More informationInsulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 V AC
Data sheet Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 AC The CM-IWS.2 serves to monitor insulation resistance in accordance with IEC 61557-8 in unearthed IT AC systems
More informationDATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC
DATASHEET - ETR4-51-A Timing relay, star-delta, 50 ms, 1W, 3-60s, 24-240VAC/DC Part no. ETR4-51-A Catalog No. 031884 Eaton Catalog No. XTTR6A60S51B EL-Nummer 0004133308 (Norway) Delivery program Product
More informationVoltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationMINI-PS AC/24DC/1.3
Power supply unit INTERFACE Data sheet 102894_en_03 1 Description PHOENIX CONTACT 2015-11-17 Features MINI POWER power supplies for MCR technology In measurement and control technology (MCR), modular electronics
More informationPower supply CP-T 48/20.0 Primary switch mode power supply
Data sheet Power supply CP-T 48/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationCP-T range Benefits and advantages
Benefits and advantages Characteristics Rated output voltages V, V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output currents 5 A, 10 A, A, A Rated output powers
More informationVEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Status indication LED U: Supply voltage
More informationElectronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts The CT-WBS.22 is a multifunctional electronic timer from the CT-S range. It provides 10 timing functions
More informationPower supply CP-T 48/5.0 Primary switch mode power supply
Data sheet Power supply CP-T 48/5.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationThree-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81
Data sheet Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81 The three-phase monitoring relays CM-PVS.x1 monitor the phase parameters phase sequence, phase failure as well as over-
More informationABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.
2CDC 251 052 F0t08 CM-MPS.23 2CDC 251 053 F0t08 CM-MPS.43 - relay status, timing - fault message - fault message Adjustment of the tripping delay t V Adjustment of the threshold value for overvoltage 6
More informationPHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.
Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data Sheet 103383_en_00 1 Description PHOENIX CONTACT - 06/2008 Features QUINT POWER power supply units highest system
More informationSolid State Relay, 1-phase
PMA Prozeß- und Maschinen-Automation GmbH Solid State Relay, 1-phase Short-Circuit Proof, heat sink integrated Main Characteristics: Standards / Approvals: CE C-Ti I Zero-point switching Short-circuit
More informationSwitching power supplies CP range, Linear power supplies CP-L range. Content
CP range, Linear power supplies CP-L range Content Switching power supplies, primary switch mode, CP range Benefits and advantages... 136 Approvals... 137 Ordering details... 138 Technical data... 11 Dimensional
More informations s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz
HPL11002EN DILETTiming relays Rated operational current AC-11 230 V 400 V I th I e I e A A A A A Conventional thermal current Time Range Voltage Article No. See price list Std. pack On-delayed Timing functions
More informationCircuit Breakers FAZ / FAZ6. Installation Products for Industrial Applications
Circuit Breakers FAZ / FAZ6 Installation Products for Industrial Applications Optimum and powerful protection for every application FAZ up to 15 ka IEC/EN 60947-2 up to 10 ka IEC/EN 60898 up to 10 ka UL
More informationE-STOP relays, safety gate monitors
Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C),
More informationType: DILEM 10(220V50HZ,240V60HZ) Article No.:
Type: DILEM 10(220V50HZ,240V60HZ) Article No.: 051785 Ordering information Actuating voltage Description Connection technique 380 V 400 V I e A 8.8 Max. rating for three phase motors, 50 AC 3 220 V 230
More informationMultifunctional three-phase monitoring relays CM-MPS CM-MPS.23
Data sheet Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 The three-phase monitoring relay CM-MPS.23 monitors the phase parameters phase sequence, phase failure, over- and undervoltage
More information400 Va.c., 500 Va.c., 690 V a.c. Rated current I n. 120 ka
Low voltage NV/NH knife-blade fuse-links Electrical characteristics Rated voltage U n 00 Va.c., 500 Va.c., 90 V a.c. Rated current I n - 0 A Breaking capacity at 1,1 U n ka Fusing characteristics gg, am,
More informationControl module CP-A CM
2CDC 271 002 F0t05 Features Pluggable onto redundancy unit CP A RU Threshold values adjustable (14 28 V) One relay output per monitored input / channel Approvals H UL 508, CAN/CSA C22.2 No.14 H UL 60950,
More informationSemiconductor contactors, Solid-state relays
Semiconductor contactors, Solid-state relays Content Benefits and advantages... 338 Approvals and marks... 338 Semiconductor contactors... 339 Ordering details... 339 R100.xx, single-phase... 339 R300.xx,
More informationPower supply CP-E 24/0.75
2CDC 271 016 F0t06 a OUTPUT L+, L : terminals output b INPUT L, N, PE: terminals input c LOW: red LED output voltage too low d OK: green LED output voltage OK e OUTPUT Adjust: rotary potentiometer output
More informationThree-phase monitoring relay CM-PVE
Data sheet Three-phase monitoring relay CM-PVE The three-phase monitoring relay CM-PVE monitors the phase parameter phase failure as well as over- and undervoltage in three-phase mains. 2CDC 251 006 S0012
More informationElectronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet
1SVR 430 103 F0200 CT-ERS 1 7 2 6 5 4 8 3 1 10 selectable time ranges, from 0.05 s to 300 h 2 Potentiometer with direct reading scale for the fine adjustment of the time delay 3 Sliding switch to set the
More informationLiquid level monitoring relay CM-ENS.2x
Data sheet Liquid level monitoring relay CM-ENS.2x The CM-ENS.2x is served to regulate and control liquid levels and ratios of mixtures of conductive fluids. It can be used for overflow protection, dry
More informationCircuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You
Circuit Breakers Excerpt from Master Catalogue Circuit Breakers Specifically For You Hydraulic-magnetic technology ensures reduced nuisance tripping with temperature variance Always holds 00% rated current
More informationElectronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts The CT-MVS.22 is a multifunctional electronic timer from the CT-S range. It provides 11 timing functions and 10 time ranges.
More informationVEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA
P Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status
More informationPHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.
Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data Sheet 103129_en_01 PHOENIX CONTACT - 05/2008 1 Description QUINT POWER power supply units highest system availability
More information3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching
Main Characteristics: Zero-point switching LED display Various connection technologies Plug-in control terminal Degree of protection IP 2 Insulated mounting foot Standards / Approvals: DIN EN 697--3 UL
More informationType: DILEM 10 G(24VDC) Article No.:
Type: DILEM 10 G(24VDC) Article No.: 010213 Ordering information Description Connection technique Rated operational current AC 3 380 V 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 220
More informationDescription Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA
Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(24V60HZ) Catalog No. 276390 Eaton Catalog No. XTRE10B22B6 Delivery program Product range DILA relays Application Contactor relays Description Basic devices
More informationPhase control Single function phase control relay - 7.5 mm Control of -phase networks: phase sequence, total phase failure Multi-voltage from x 08 to x 480 V Controls its own supply voltage True RMS measurement
More information3 - Protection components Circuit-breakers
Contents - Protection components Circuit-breakers for the motor protection Selection guide..............................................page /2 Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More information38 Series - Relay interface modules A. Features /
Series - Relay interface modules 0.1-2 - 6-8 A Features 1 Pole - 6 A electromechanical relay interface modules, 6.2 mm wide. Ideal interface for PLC and electronic systems Sensitive DC coil or coil versions
More informationDescription Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA
DATASHEET - DILA-22(230V50HZ,240V60HZ) Delivery program Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(230V50HZ,240V60HZ) Catalog No. 276399 Eaton Catalog No. XTRE10B22F EL-Nummer 0004130208 (Norway)
More informationThree-phase monitoring relay CM-PBE
Data sheet Three-phase monitoring relay CM-PBE The three-phase monitoring relay CM-PBE monitors the phase parameter phase failure in three-phase mains. 2CDC 251 007 S0012 Characteristics Monitoring of
More information