1 Wireless System RoHS Usable even in welding environments Noise resistance Uses the. GHz ISM frequency band Frequency hopping: Every ms Communication cables not required Reduced wiring work, space, and cost Minimized disconnection risk High-speed connection From power supply ON to start of communication: Min. 0 ms * * For wireless slave Number of I/O points Max. 80 inputs/80 outputs (Registration and communication of up to 7 slave units is possible.) Communication response Signal response time: ms Compatible protocol Material handling robot Wireless master Wireless slave Spot welding Countries in which wireless is supported This product cannot be used in countries where wireless is not supported. (For details a p. ) Wireless slave Country Standard Wireless master unit Wireless slave unit Japan EU (Japanese radio law) (CE marking/re Directive) EX600-W Series USA (FCC) CAT.E0-8A

2 Wireless System EX600-W Series Provide safe and reliable communication Uses the. GHz ISM frequency band khz MHz GHz Wireless System Wireless LAN Wireless devices Site noise RFID Bluetooth AC/DC welding machine Motor driver/ Electromagnetic heater, etc. * ISM (Industrial, Scientific and Medical) radio bands: Radio bands reserved for the use of radio frequency energy for industrial, scientific and medical purposes. Provide stable communication Communications using various forms of radio wave propagation PLC Power supply Wireless master Communication possible in a 0 m radius Reflected wave Noise in electronic circuits Transmitted wave Direct wave Wireless slave Interference from other wireless equipment

3 Wireless System EX600-W Series Frequency Actual communication time ms Frequency of the radio wave interference Time Communication frequency interference (for example, Wi-Fi) Frequency hopping: Every ms A stable wireless environment is established using an original protocol which is not affected by interference. Interference from other wireless equipment is prevented. Frequency Hopping The communication technology rapidly changes frequency (hopping), to prevent interference from other wireless equipment. When the frequency of Wi-Fi and other wireless communications compete, or radio wave interference is present, then other frequencies are used for communication. For details, refer to technical data on page. High security using encryption Unauthorized access from outside is prevented by using data encryption. Unauthorized access/ data falsification Wireless master Unauthorized wiretapping Wireless slave Removing device Wireless communication status can be monitored. <Monitoring the slave communication status> The wireless system connection can be monitored during operation according to the diagnostic data. The installation location can be ascertained according to the intensity level of the radio wave received by the unit display. [Diagnostic data] * When communication from the slave cannot be received. * When communication retry has exceeded the upper limit ( times). [Unit display] For wireless master W-SS (Radio wave receiving intensity (For communication from wireless slave to wireless master)) Green LED is ON. Green LED flashes. ( Hz) Green LED flashes. ( Hz) Red LED flashes. OFF Received power level of all slaves is. There are connected slaves with received power level. There are connected slaves with received power level. No wireless slaves connected. Wireless slave unit is not registered. For wireless slave W-SS (Radio wave receiving intensity (Communication from wireless master to wireless slave)) Green LED is ON. Green LED flashes. ( Hz) Received power level is. Received power level is. Point-to-Multipoint communication Registration and communication of up to 7 wireless slave units is possible. Wireless master 7 units Green LED flashes. ( Hz) Red LED flashes. Received power level is. Wireless communication is not connected. Wireless master unit is not registered. OFF * A received radio wave intensity level of means the intensity is weak. Add a wireless master so that the wave intensity becomes level or. Alternatively remove the obstacle between the master and slave, or reduce the distance between the master and slave. <Communication status can be downloaded by a PC> By connecting the wireless master to a PC, it is possible to view log files which show the number of retries or the received radio wave intensity. Log files are accessed by using a web browser to connect to the built-in WEB server. The wireless environment and installation location can be optimized by checking the number of retries and received radio wave intensity. The log files showing the number of retries or the received radio wave intensity, can be downloaded in the form of a CSV file. Wireless slave Wireless slave Wireless slave Wireless slave * to units are recommended for simultaneous operation * It is possible to install multiple wireless masters in the same area Web screen example PC

4 Wireless System EX600-W Series Wiring material cost and installation man-hours can be reduced. Wireless System Current (Wired) System PLC Power supply Wireless master PLC Power supply line Power supply Communication line q Communication line q Power supply unit units units Connector units unit units units units Wireless slave Wireless slave Wireless slave SI unit Communication line w Communication line w Power supply line Power supply line SI unit: Comparison when units are connected Wireless system Current (Wired) Number of communication devices Wireless master: unit Wireless slave: units SI unit: units q Communication line w Communication connectors required line place (Connector at one end) line lines 9 places (Connector at one end) (Connector at both ends) Interchangeability maintained Connection interchangeability between EX600 series SI units is maintained. Replacement of wireless and wired systems is possible. Wireless system Wireless unit Wired system * Maximum I/O of wireless master/ slave unit is limited to 8 points. SI unit NFC contactless communication (NFC: Near Field Communication) Settings are possible using an NFC reader/ writer and setting software. (Some items can be set when there is no power supplied) Write IP address to the master Set the I/O points for the system and unit Pairing of the master and slave IO monitoring NFC reader/ writer Configuration File From SMC website Documents/Download Instruction Manuals Fieldbus System Serial Transmission System EtherNet/IP Compatible I/O Configurator for NFC Configuration File PC + Setting software

5 Wireless System EX600-W Series Application Examples Tool change Communication cable is not necessary for moving parts. Minimized disconnection risk Shorter time for establishing communication (startup time) Rotary table Minimized disconnection risk Smaller diameter communication cable/tubing Wired system Communication line Power supply line Power supply line only Blocking of radio waves * The radio waves must not be blocked by nearby conductive objects such as metal enclosures or covers.

6 Wireless System EX600-W Series System Examples Setting/Monitor tool Initial setting/monitoring/ pairing are possible. PLC Fieldbus PC Wireless Network EX600 I/O unit Refer to the Web Catalog. Wireless master unit p. 7 Number of I/O points: Max. 80 inputs 80 outputs Combination Example q Wireless slave unit No. p. 7 EX600 I/O unit Solenoid valve Combination Example w Wireless slave unit No. p. 7 EX600 I/O unit Combination Example e Wireless slave unit No. p. 7 Solenoid valve Other products Pressure switch, flow switch, auto switch, and other switches (proximate sensor, photoelectric switch, limit switch, etc.) Various actuators Applicable Manifold Solenoid Valves SY Series (IP67) SV Series (IP67) S0700 Series (IP0) VQC Series (IP67)

7 CONTENTS Wireless System EX600-W Series Wireless master unit Wireless slave unit How to Order Wireless Unit p. 7 Digital Input Unit p. 7 Digital Output Unit p. 7 Digital Input/Output Unit p. 7 Analog Input Unit p. 8 Analog Output Unit p. 8 Analog Input/Output Unit p. 8 End Plate (D side) p. 8 End Plate (U side) p. 8 Ordering Example of the Master Unit p. 9 Ordering Example of the Slave Unit p. 9 Wireless Master Unit p. 0 Wireless Slave Unit p. End Plate (D side) p. Dimensions p. LED Display p. Accessories qend Plate Bracket p. 7 wvalve Plate p. 7 ereinforcing Brace p. 7 rseal Cap p. 7 tmarker p. 8 ycommunication Cable with Connector/ Communication Connector p. 8 u Power Supply Cable with M Connector (A-coded) p. 9 u Power Supply Cable with M Connector (B-coded) p. 0 i Power Supply Cable with 7/8 Inch Connector/ Power Supply Connector p. Technical Data p. Important p. Safety Instructions Back Cover 6

8 Wireless System EX600-W Series RoHS How to Order SI Unit EX600 W EN Wireless compatible SI unit Symbol Note EN Wireless master unit For EtherNet/IP SV Wireless slave unit Output type Symbol PNP NPN Wireless master unit Wireless slave unit Digital Input Unit EX600 Symbol P N DX Input type Description PNP NPN * For specifications, refer to the Fieldbus system EX600 series in the Web Catalog. P D Number of inputs and Connector Symbol Number of inputs Connector B 8 inputs M connector ( pins) pcs. C 8 inputs M8 connector ( pins) 8 pcs. D 6 inputs M connector ( pins) 8 pcs. E 6 inputs D-sub connector ( pins) F 6 inputs Spring type terminal block ( pins) Digital Output Unit EX600 DY P Output type Symbol Description P PNP N NPN B Number of outputs and Connector Symbol Number of outputs Connector B 8 outputs M connector ( pins) pcs. E 6 outputs D-sub connector ( pins) F 6 outputs Spring type terminal block ( pins) * For specifications, refer to the Fieldbus system EX600 series in the Web Catalog. Digital Input/Output Unit EX600 DM P Input/Output type Symbol Description P PNP N NPN F Number of inputs/outputs and Connector Symbol Number of inputs Number of outputs Connector E 8 inputs 8 outputs D-sub connector ( pins) F 8 inputs 8 outputs Spring type terminal block ( pins) * For specifications, refer to the Fieldbus system EX600 series in the Web Catalog. 7

9 Wireless System EX600-W Series How to Order Analog Input Unit EX600 AX A Analog input Number of input channels and Connector Symbol Number of input channels Connector A channels M connector ( pins) pcs. * For specifications, refer to the Fieldbus system EX600 series in the Web Catalog. Analog Output Unit EX600 AY A Analog output Number of output channels and Connector Symbol Number of output channels Connector A channels M connector ( pins) pcs. * For specifications, refer to the Fieldbus system EX600 series in the Web Catalog. Analog Input/Output Unit EX600 Analog input/output * For specifications, refer to the Fieldbus system EX600 series in the Web Catalog. AM B Number of input/output channels and Connector Symbol Number of input channels Number of output channels Connector B channels channels M connector ( pins) pcs. End Plate (D side) For M For 7/8 inch EX600 E D End plate End plate mounting position: D side Power supply connector Symbol Power supply connector M ( pins) B-coded IN 7/8 inch ( pins) IN M (/ pins) A-coded * IN/OUT M (/ pins) A-coded * IN/OUT * The pin layout for and pin connector is different. Refer to the dimensions on page. Mounting method Symbol Description Note Nil Without DIN rail mounting bracket With DIN rail mounting bracket For SV, S0700, VQC series With DIN rail mounting bracket For SY series * When the end plate (U side) is used, the symbol for the mounting method must be the same as the D side. End Plate (U side) EX600 E U End plate End plate mounting position: U side Symbol Waterproof cover Mounting method Symbol Description Nil Without DIN rail mounting bracket With DIN rail mounting bracket * When the end plate (D side) is used, the symbol for the mounting method must be the same as the U side. 8

10 EX600-W Series Ordering Example of the Master Unit Master unit: Without valve manifold and input/output unit Manifold with master unit: With input/output unit Wireless unit (Wireless master unit) EX600-WEN End plate (D side) EX600-ED End plate (U side) EX600-EU Digital input unit EX600-DXPD End plate (D side) EX600-ED Digital output unit EX600-DYPB Wireless unit (Wireless master unit) EX600-WEN -position single SY00-U ( sets) -position double SY00-U ( sets) 0 B A B A B A B A B A A A A A A D side U side D side 0 U side B B B B B 8 7 Valve stations EX600-ED set EX600-WEN set EX600-EU set Products should be ordered separately and assembled by the customer. SSY-0S6WE7-0B-C6 (Type 0 -station manifold base, Wireless EtherNet/IP ) Negative common, M connector IN/OUT, I/O unit: stations * SY00-U sets (-position single part no.) * SY00-U sets (-position double part no.) * EX600-DXPD set I/O unit part no. (Stations ) * EX600-DYPB set I/O unit part no. (Stations ) The asterisk denotes the symbol for the assembly. Prefix it to the part numbers of the valve, etc. For details, refer to the catalog of each valve series. Ordering Example of the Slave Unit Slave unit: Without valve manifold and with input/output unit Manifold with slave unit: With input/output unit Digital output unit EX600-DYPB Digital input unit EX600-DXPD End plate (D side) EX600-ED Wireless unit (Wireless slave unit) EX600-WSV End plate (U side) EX600-EU Digital input unit EX600-DXPD End plate (D side) EX600-ED Digital output unit EX600-DYPB Wireless unit (Wireless slave unit) EX600-WSV -position single SY00-U ( sets) -position double SY00-U ( sets) 0 0 B A B A B A B A B A A A A A A D side 0 U side D side 0 U side B B B B B Valve stations EX600-ED set EX600-DXPD set EX600-DYPB set EX600-WSV set EX600-EU set Products should be ordered separately and assembled by the customer. SSY-0S6WS7-0B-C6 (Type 0 -station manifold base, Wireless slave) Negative common, M connector IN/OUT, I/O unit: stations * SY00-U sets (-position single part no.) * SY00-U sets (-position double part no.) * EX600-DXPD set I/O unit part no. (Stations ) * EX600-DYPB set I/O unit part no. (Stations ) The asterisk denotes the symbol for the assembly. Prefix it to the part numbers of the valve, etc. For details, refer to the catalog of each valve series. 9

11 Wireless System EX600-W Series Wireless Master Unit: EX600-WENm EtherNet/IP communication Wireless communication Electrical Input/Output General NFC communication* Item Communication protocol EtherNet/IP (Conformance test version: Composit ) Transmission medium (cable) Standard Ethernet cable (CAT or higher, 00BASE-TX) Communication speed 0 Mbps/00 Mbps Communication method Full duplex/half duplex Configuration file EDS file* IP address setting Manual/BOOTP, DHCP Vendor ID: 7 (SMC Corp.) Device information Device type: (Communication Adaptor) Product code: 86 Topology Star, Bus, Ring (DLR), Line, Tree QuickConnect function Applicable DLR function Applicable Web server function Applicable Protocol SMC original protocol (SMC encryption) Radio wave type (spread) Frequency Hopping Spread Spectrum (FHSS) Frequency. GHz (0 to 8 MHz) Number of frequency channels 79 ch (Bandwidth:.0 MHz) Communication speed 0 kbps Communication distance 0 m (Depending on the operating environment) Radio Law certificate Japanese radio law (Japan), RE (EU* ), FCC (USA) For control/input Power supply voltage VDC ±0% (US) Current consumption 0 ma or less For output Power supply voltage VDC ±0% (US) Max. supply current A Number of System input size Max. 80 points together with the registered slave units inputs Input size Max. 8 points (increase or decrease by 6 points) Number of System output size Max. 80 points together with the registered slave units outputs Output size Max. 8 points (increase or decrease by 6 points) Analog AD refresh time 0 ms or less (the input connected to the master unit) input/output DA refresh time 0 ms or less (the output connected to the master unit) EX600-WEN: Source/PNP ( COM) Output type EX600-WEN: Sink/NPN (+COM) Valve output Number of outputs Max. points (0/8/6// points) Connected load Solenoid valve with surge voltage suppressor of VDC and. W or less (manufactured by SMC) Number of slave units connected Max. 7 units (0///6/7 units) Number of connected EX600 I/O units Max. 9 EX600 series I/O units (I/O = 8. I/O above 8 cannot be recognized.) Enclosure IP67 equivalent (with manifold assembled) Ambient temperature (Operating temperature) 0 to +0 C Ambient temperature (Storage temperature) 0 to +60 C Ambient humidity to 8% RH (No condensation) Withstand voltage 00 VAC for minute between external terminals and metallic parts Insulation resistance 0 MΩ or more (00 VDC between external terminals and metallic parts) Standards CE marking, RoHS compliant Weight 00 g Communication standard ISO/IECB (Type-B) Frequency.6 MHz Communication speed 0 to 00 khz (IC) Communication distance Up to cm * The configuration file can be downloaded from the SMC website: * Austria, Belgium, Bulgaria, Croatia, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Latvia, Lithuania, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, U.K., Turkey * The NFC communication RFID tag of the.6 MHz passive type Trademark EtherNet/IP is a trademark of ODVA. 0

12 EX600-W Series Wireless Slave Unit: EX600-WSVm Electrical Input/Output Wireless communication General NFC communication* Item For control/input Power supply voltage VDC ±0% (US) Current consumption 70 ma or less For output Power supply voltage VDC ±0% (US) Max. supply current A Number of inputs Input size Max. 8 points (increase or decrease by 6 points) Number of outputs Output size Max. 8 points (increase or decrease by 6 points) EX600-WSV: Source/PNP ( COM) Output type EX600-WSV: Sink/NPN (+COM) Valve output Number of valve manifold connections Max. points (0/8/6// points) Connected load Solenoid valve with surge voltage suppressor of VDC and. W or less (manufactured by SMC) AD/DA refresh time 0./0./0.////0/0/60 s* Number of connected EX600 I/O units Max. 9 EX600 I/O units (I/O = 8. I/O above 8 cannot be recognized.) Protocol SMC original protocol (SMC encryption) Radio wave type (spread) Frequency Hopping Spread Spectrum (FHSS) Frequency. GHz (0 to 8 MHz) Number of frequency channels 79 ch (Bandwidth:.0 MHz) Communication speed 0 kbps Communication distance 0 m (Depending on the operating environment) Radio Law certificate Japanese radio law (Japan), RE (EU* ), FCC (USA) Enclosure IP67 equivalent (with manifold assembled) Ambient temperature (Operating temperature) 0 to +0 C Ambient temperature (Storage temperature) 0 to +60 C Ambient humidity to 8% RH (No condensation) Withstand voltage 00 VAC for minute between external terminals and metallic parts Insulation resistance 0 MΩ or more (00 VDC between external terminals and metallic parts) Standards CE marking, RoHS compliant Weight 80 g Communication standard ISO/IECB (Type-B) Frequency.6 MHz Communication speed 0 to 00 khz (IC) Communication distance Up to cm * Austria, Belgium, Bulgaria, Croatia, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Latvia, Lithuania, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, U.K., Turkey * Varies depending on the wireless communication status and the surrounding environment. * The NFC communication RFID tag of the.6 MHz passive type End Plate (D side): EX600-ED/-m Item Connector type PWR IN M plug, -pin PWR OUT M socket, -pin Electrical Rated voltage Power supply for output VDC +0%/ % Power supply for control/input VDC ±0% (the power supply for the unit is shut off at 7 V or less) Rated current Power supply for output Max. A Power supply for control/input Max. A Enclosure IP67 (with manifold assembled) Withstand voltage 00 VAC for minute (between FE and external terminals) Insulation resistance 0 MΩ or more (00 VDC between FE and external terminals) General Ambient Operating 0 to +0 C temperature Stored/Transported 0 to +60 C Ambient humidity % to 8% RH (No condensation) Standards CE marking, RoHS compliant * For the EX600-ED/-m, refer to the Fieldbus system EX600 series in the Web Catalog.

13 Wireless System EX600-W Series Dimensions Wireless master unit: EX600-WENm Area close to NFC antenna FCC ID label 06 EtherNet/IP BUS connector, Port Marker groove EtherNet/IP BUS connector, Port 6. 8 Model label ID label (Ethernet MAC address, Wireless PID (Product ID)) Connector for EtherNet/IP Port /Port M, -pin, D-coded, socket Pin no. Description Tx+ Rx+ Tx Rx Wireless slave unit: EX600-WSVm Area close to NFC antenna FCC ID label 06 Marker groove 6. 8 ID label (Wireless PID (Product ID)) Model label

14 EX600-W Series Dimensions End plate (D side) EX600-ED Power supply connector PWR: M -pin plug, B-coded Configuration Pin no. Description V (for output) 0 V (for output) V (for control/input) 0 V (for control/input) FE EX600-ED Power supply connector PWR: 7/8 inch -pin plug Configuration Pin no. Description 0 V (for output) 0 V (for control/input) FE V (for control/input) V (for output)

15 Wireless System EX600-W Series Dimensions End plate (D side) EX600-ED/ (.) Power supply connector PWR IN FE terminal Power supply connector PWR OUT (86.6) Power supply connector PWR IN: M -pin plug, A-coded Configuration EX600-ED (Pin arrangement ) EX600-ED (Pin arrangement ) Pin no. Description Pin no. Description V (for control/input) V (for output) V (for output) 0 V (for output) 0 V (for control/input) V (for control/input) 0 V (for output) 0 V (for control/input) Power supply connector PWR OUT: M -pin socket, A-coded EX600-ED (Pin arrangement ) EX600-ED (Pin arrangement ) Configuration Pin no. Description Pin no. Description V (for control/input) V (for output) V (for output) 0 V (for output) 0 V (for control/input) V (for control/input) 0 V (for output) 0 V (for control/input) Unused Unused End plate (U side) EX600-EU x M direct mounting hole SI unit mounting hole x. 6.7

16 EX600-W Series LED Display Wireless master unit EtherNet/IP communication specifications w q r u e y t No. LED name Function Color of LED Operation Power supply Green LED is ON. Power supply voltage for output (US) is normal. PWR (V) voltage for Red LED flashes. Power supply voltage for output (US) is abnormal. (Indication only. The product can be operated.) output (US) OFF Power supply for control and input (US) is not supplied. Green LED is ON. EtherNet/IP communication is established. EtherNet/IP Green LED flashes. EtherNet/IP communication is not established. NS connection Red LED flashes. EtherNet/IP communication time out status Red LED is ON. Duplicated IP addresses are detected. OFF IP address not set Green LED is ON. Wireless master module is normal. Green LED flashes. EtherNet/IP communication is not connected. MS Wireless master module system status Red LED flashes. Restorable error is detected. (LED flashes when one diagnostic information item or more is detected.) Abnormal power supply voltage level for control and input Excessive I/O setting inputs/outputs Analog I/O upper set limit exceeded Analog I/O upper and lower limit exceeded Abnormal number of slave connections Error in communication between units EX600 I/O unit detects diagnostic information Valve diagnostic information detected W-SS W-NS 6 W-MS Radio wave receiving intensity (For communication from wireless slave to wireless master) Wireless communication connection status Wireless slave module connection system status Red LED is ON. Non-restorable error is detected. (e.g. Hardware failure) OFF Power supply for control and input (US) is not supplied. Green LED is ON. Received power level of all slaves is. Green LED flashes. ( Hz) There are connected slaves with received power level. Green LED flashes. ( Hz) There are connected slaves with received power level. Red LED flashes. No wireless slaves connected. OFF Wireless slave unit is not registered. Green LED is ON. All wireless slave units are connected correctly. Green LED flashes. There are unconnected wireless slave units. Red LED flashes. All wireless slave units are unconnected. Red LED is ON. All wireless slave units are unconnected. (Non-restorable error in wireless communication) Red/Green Wireless communication connection is under construction. (Pairing) Orange LED is ON. Forced output mode OFF Wireless slave unit is not registered. Green LED is ON. Wireless slave module is normal. Restorable error is detected. (LED flashes when one diagnostic information item or more is detected.) Abnormal power supply voltage level for control and input (US) Abnormal power supply voltage level for output (US) Red LED flashes. Excessive I/O setting inputs/outputs Analog I/O upper set limit exceeded Analog I/O upper and lower limit exceeded Error in communication between units EX600 I/O unit detects diagnostic information Valve diagnostic information detected 7 LINK/ACT LINK/ACT Communication status of EtherNet/IP ports and 00 Mbps: Green 0 Mbps: Orange Red LED is ON. OFF Green LED is ON. Green LED flashes. Orange LED is ON. Orange LED flashes. Red LED is ON. OFF Non-restorable error is detected. (e.g. Hardware failure) No wireless slave unit connected. Link, No Activity (00 Mbps) Link, Activity (00 Mbps) Link, No Activity (0 Mbps) Link, Activity (0 Mbps) IP address has been duplicated. EtherNet/IP is not connected.

17 Wireless System EX600-W Series LED Display Wireless slave unit q w e r No. LED name Function Color of LED Operation Power supply Green LED is ON. Power supply voltage for output (US) is normal. PWR (V) voltage for Red LED flashes. Power supply voltage for output (US) is abnormal. (Indication only. The product can be operated.) output (US) OFF Power supply for control and input (US) is not supplied. Green LED is ON. Wireless slave module is normal. MS W-SS W-NS Wireless slave module system status Radio wave receiving intensity (Communication from wireless master to wireless slave) Wireless communication connection status Red LED flashes. Restorable error is detected. (LED flashes when one diagnostic information item or more is detected.) Abnormal power supply voltage level for control and input Excessive I/O setting inputs/outputs Analog I/O upper set limit exceeded Analog I/O upper and lower limit exceeded Error in communication between units EX600 I/O unit detects diagnostic information Valve diagnostic information detected Red LED is ON. Non-restorable error is detected. (e.g. Hardware failure) OFF Power supply for control and input (US) is not supplied. Green LED is ON. Received power level is. Green LED flashes. ( Hz) Received power level is. Green LED flashes. ( Hz) Received power level is. Red LED flashes. Wireless communication is not connected. OFF Wireless master unit is not registered. Green LED is ON Wireless slave is connected correctly. Red LED flashes. No wireless slaves connected. Red LED is ON. No wireless slaves connected (Non-restorable error in wireless communication) Red/Green Wireless communication connection is under construction. (Pairing) Orange LED is ON. Forced output mode OFF Wireless master unit is not registered. 6

18 EX600-W Series Accessories (Optional Parts) u Power supply cable with connector y Communication cable with connector r Seal cap (M8) t Marker w Valve plate r Seal cap (M) i Power supply cable (7/8 inch connector) e Reinforcing brace (for direct mounting) q End plate bracket e Reinforcing brace (for DIN rail mounting) i Power supply field wireable connector (7/8 inch) q End Plate Bracket This bracket is used for the end plate of DIN rail mounting. EX600-ZMA EX600-ZMA (Specialized for the SY series) Enclosed parts Round head screw (M x 0) pc. P-tight screw ( x ) pcs. Enclosed parts Round head screw with washer (M x 0) P-tight screw ( x ) pc. pcs. e Reinforcing Brace This bracket is used on the bottom of the unit at the intermediate position for connecting 6 units or more. * Be sure to attach this bracket to prevent connection failure between the units caused by deflection. For direct mounting EX600-ZMB Enclosed parts Round head screw (M x ) pcs. For DIN rail mounting EX600-ZMB Enclosed parts Round head screw (M x 6) pcs. w Valve Plate EX600-ZMV Enclosed parts Round head screw (M x 6) pcs. Round head screw (M x 8) pcs. EX600-ZMV (Specialized for the SY series) Enclosed parts Round head screw (M x 6) pcs. Round head screw (M x 8) pcs. r Seal Cap (0 pcs.) Be sure to mount a seal cap on any unused I/O connectors. Otherwise, the specified enclosure cannot be maintained. For M8 EX9-AWES For M EX9-AWTS 7

19 EX600-W Series Accessories t Marker ( sheet, 88 pcs.) The signal name of I/O device and each unit address can be entered and mounted on each unit. EX600-ZT y Communication Cable with Connector/Communication Connector Cable with M RJ- connector M 000 mm 000 mm 000 mm 000 mm 0000 mm RJ- ø6. Cable length (L) ø.8 EX9-AC 00 EN-PSRJ (Plug/RJ- connector) L (7.) Plug connector D-coded () Cable core Terminal no. wire colors Terminal no White/Orange Orange White/Green Pair Pair Green Shield Plug connector Connections (Straight cable) Item Cable O.D. Nominal cross section Wire diameter Min. bending radius Field wireable connector PCA-666 (Plug) PCA-6 M SPEEDCON Plug connector D-coded 0 M Terminal no. Item Cable O.D. Nominal cross section Wire diameter (Including insulator) Min. bending radius 6 ø9 000 (ø6.) ø.8 7. ø7. Cable with connector ø6. mm 0. mm/awg mm 6 mm (Fixed) Wire guide colors Yellow: TD+ White: RD+ Orange: TD Blue: RD Connections ø6. mm AWG. mm. mm Width across flats 6 Plug pin arrangement D-coded Width across flats Terminal no. Wire guide colors Orange/White Green/White Orange Green Applicable Cable Cable O.D. Wire gauge (Stranded wire cross section).0 to 8.0 mm 0. to 0. mm/awg6 to he table above shows the specifications for the applicable cable. * T Adaptation for the connector may vary on account of the conductor construction of the electric wire. 8

20 EX600-W Series u Power Supply Cable with M Connector (A-coded) EX00-AP 00 - S Cable length (L) mm mm Connector specification S Straight A Angle Straight connector type Angle connector type ø.9 M M ø.9 ø6 8. ø6 Socket connector A-coded (Normal key) L 0 0 Socket connector A-coded (Normal key). L 0 0 Item Cable O.D. Nominal cross section Wire diameter (Including insulator) Min. bending radius ø6 mm 0. mm /AWG. mm 0 mm (Fixed) Item Cable O.D. Nominal cross section Wire diameter (Including insulator) Min. bending radius ø6 mm 0. mm /AWG. mm 0 mm (Fixed) Terminal no. Cable core wire colors Brown White Blue Black Gray Connections SPEEDCON PCA- 080 PCA Cable length (L) mm mm mm Cable length (L) mm ø.8. L 0 ø.8 L 6.8 ø.8 Socket connector A-coded (Normal key) Terminal no. M SPEEDCON Cable core wire colors Brown White Blue Black Green/Yellow ø Item Cable O.D. Nominal cross section Wire diameter (Including insulator) Min. bending radius ø mm 0. mm /AWG.7 mm.7 mm (Fixed) M SPEEDCON ø.7 Connections Socket connector A-coded (Normal key) M SPEEDCON Plug connector A-coded (Normal key) 9 Connections

21 Accessories EX600-W Series u Power Supply Cable with M Connector (B-coded) SPEEDCON PCA- 697 Socket specification, Cable length (L) 697 Straight m 690 Straight 6 m 69 Angle m 6969 Angle 6 m Straight connector type Angle connector type ø.8. L 0 6. L 0 Socket connector B-coded (Reverse key) Terminal no. Connections M SPEEDCON ø.9 Cable core wire colors Brown: VDC (for solenoid valve) White: 0 V (for solenoid valve) Blue: VDC (for control and input) Black: 0 V (for control and input) Gray: Not connected Terminal no. 8 Socket connector B-coded (Reverse key) Connections M SPEEDCON ø.8 ø.9 Cable core wire colors Brown: VDC (for solenoid valve) White: 0 V (for solenoid valve) Blue: VDC (for control and input) Black: 0 V (for control and input) Gray: Not connected 0

22 EX600-W Series i Power Supply Cable with 7/8 Inch Connector/Power Supply Connector PCA- 880 Symbol Cable length (L) Connector specification Straight Straight Right angle Right angle Straight connector type Angle connector type ø6 Socket connector 7/8 inch (Mini style) ø7/8" Connections 9.9 L 6 ø.8 Cable core wire colors Red/White: 0 V (for solenoid valve) Red: 0 V (for control and input) Green: FE Red/Orange: VDC (for control and input) Red/Black: VDC (for solenoid valve) Socket connector 7/8 inch (Mini style) Connections ø7/8" ø6 L ø.8 Cable core wire colors Red/White: 0 V (for solenoid valve) Red: 0 V (for control and input) Green: FE Red/Orange: VDC (for control and input) Red/Black: VDC (for solenoid valve) Field wireable connector PCA Symbol Connector specification Plug 7808 Socket ø7 ø7 ø7 ø7 Width across flats Plug connector 7/8 inch (Mini style) Socket connector 7/8 inch (Mini style) Terminal no. Wire guide colors Red/White Red Green Red/Orange Red/Black Applicable Cable Cable O.D..0 to.0 mm Wire gauge 0. to. mm (Stranded wire cross section) /AWG to 6 * The table above shows the specifications for the applicable cable. Adaptation for the connector may vary on account of the conductor construction of the electric wire. * For further information on cables and connectors, refer to the M8/M connector PCA series in the Web Catalog.

23 EX600-W Series Technical Data Frequency Hopping (FHSS: Frequency Hopping Spread Spectrum) A communication technology that uses spread spectrum transmission with frequency hopping to rapidly switch the frequency. Because the frequency rapidly changes all the time, this communication method is resistant to radio wave interference due to reflections or noise from other wireless equipment, while ensuring a high level of data security. Multiple systems can be installed in the same area, and it is a suitable technology for point-to-multipoint communication. Without frequency hopping With frequency hopping Time Communication time Communication packet ( data packet for communication) Time Communication time Transmission frequency f [GHz] f_t e f_t q f_t r w f_t f_t Frequency Frequency When a radio interference is present at a specific frequency, communication is maintained by moving to another frequency. Frequency band of radio wave interference Time Wi-Fi When the communication competes with other systems (Wi-Fi, etc.), the unit changes to another frequency to continue communicating. Communication time Frequency <Important> V The product is certified as a wireless equipment in accordance with the Radio Act and the certificate of Technical Standard Conformity has been obtained. Customers do not need to apply for a license to use this equipment. Be sure to comply with the following precautions. Do not disassemble or modify the product. Disassembly and modification are prohibited by law. This product is for use in Japan, European countries (Austria, Belgium, Bulgaria, Croatia, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Latvia, Lithuania, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, U.K., Turkey), and the U.S. For use in other countries, please contact SMC. V This product communicates by radio waves, and the communication may stop instantaneously due to ambient environments and operating methods. SMC will not be responsible for any secondary failure which may cause an accident or damage to other devices or equipment. V When several units are installed closely to each other, slight interference may occur due to the characteristics of the wireless product. V Do not use this product close to any equipment which may cause malfunction due to radio waves from this product. V The communication performance is affected by the ambient environment, so please perform the communication testing before use.

24 Safety Instructions Caution: Warning: Danger : Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger. They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC) ), and other safety regulations. ) ISO : Pneumatic fluid power General rules relating to systems. ISO : Hydraulic fluid power General rules relating to systems. IEC 600-: Safety of machinery Electrical equipment of machines. (Part : General requirements) ISO 08-: Manipulating industrial robots Safety. etc. Warning. The compatibility of the product is the responsibility of the person who designs the equipment or decides its specifications. Since the product specified here is used under various operating conditions, its compatibility with specific equipment must be decided by the person who designs the equipment or decides its specifications based on necessary analysis and test results. The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product. This person should also continuously review all specifications of the product referring to its latest catalog information, with a view to giving due consideration to any possibility of equipment failure when configuring the equipment.. Only personnel with appropriate training should operate machinery and equipment. The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced.. Do not service or attempt to remove product and machinery/ equipment until safety is confirmed.. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed.. When the product is to be removed, confirm that the safety measures as mentioned above are implemented and the power from any appropriate source is cut, and read and understand the specific product precautions of all relevant products carefully.. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction.. Contact SMC beforehand and take special consideration of safety measures if the product is to be used in any of the following conditions.. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to direct sunlight.. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the standard specifications described in the product catalog.. An application which could have negative effects on people, property, or animals requiring special safety analysis.. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation. Compliance Requirements Caution. The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch. Limited warranty and Disclaimer/ Compliance Requirements The product used is subject to the following Limited warranty and Disclaimer and Compliance Requirements. Read and accept them before using the product. Limited warranty and Disclaimer. The warranty period of the product is year in service or. years after the product is delivered, whichever is first. ) Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch.. For any failure or damage reported within the warranty period which is clearly our responsibility, a replacement product or necessary parts will be provided. This limited warranty applies only to our product independently, and not to any other damage incurred due to the failure of the product.. Prior to using SMC products, please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products. ) Vacuum pads are excluded from this year warranty. A vacuum pad is a consumable part, so it is warranted for a year after it is delivered. Also, even within the warranty period, the wear of a product due to the use of the vacuum pad or failure due to the deterioration of rubber material are not covered by the limited warranty.. The use of SMC products with production equipment for the manufacture of weapons of mass destruction (WMD) or any other weapon is strictly prohibited.. The exports of SMC products or technology from one country to another are governed by the relevant security laws and regulations of the countries involved in the transaction. Prior to the shipment of a SMC product to another country, assure that all local rules governing that export are known and followed. Caution SMC products are not intended for use as instruments for legal metrology. Measurement instruments that SMC manufactures or sells have not been qualified by type approval tests relevant to the metrology (measurement) laws of each country. Therefore, SMC products cannot be used for business or certification ordained by the metrology (measurement) laws of each country. Safety Instructions Be sure to read the Handling Precautions for SMC Products (M-E0-) and Operation Manual before use.

Less is definitely more Fieldbus wireless system EX600-W Series

Less is definitely more Fieldbus wireless system EX600-W Series Less is definitely more Fieldbus wireless system Fieldbus wireless system RoHS Less cables & connectors, less installation & maintenance, less breakage & disconnection risk. Less Wireless system Achieve

More information

Name Number of I/O points (words used) Model Antenna style. 512 outputs max. (32 words) Magnetic Base Antenna (1) --- WD30-AT001 (See note.

Name Number of I/O points (words used) Model Antenna style. 512 outputs max. (32 words) Magnetic Base Antenna (1) --- WD30-AT001 (See note. DeviceNet Wireless Communication WD30 The DeviceNet wireless units, consisting of a DeviceNet wireless master station and a DeviceNet wireless slave station, allow wireless communication with DeviceNet

More information

FA Wireless SS Terminals

FA Wireless SS Terminals FA Wireless SS Terminals WT30 Construct a Wireless System for ON/OFF Data Collection That Is Ideal for Monitoring Production Site Equipment Wireless Slave Station equipped with I/O. Height of 90 mm and

More information

Speed Controller with One-touch Fittings In-line Type

Speed Controller with One-touch Fittings In-line Type Speed Controller with One-touch Fittings In-line Type New RoHS types of mounting variations Direct mounting DIN rail mounting mounting Holder mounting DIN rail mounting bracket Holder for speed controller

More information

High-speed, wireless communication with easy installation and simple wiring!! *Antenna sold separately. 250 m range. Antenna with cable available

High-speed, wireless communication with easy installation and simple wiring!! *Antenna sold separately. 250 m range. Antenna with cable available WIRELESS UNIT High-speed, wireless with easy installation and simple wiring!! Antenna with cable *Antenna sold separately. Antenna extension cable High-speed data transfer (2.4 GHz, SS wireless) 250 m

More information

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9853E 2-Port, High-Speed CAN Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9853E 2-Port, High-Speed CAN Module OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9853E 2-Port, High-Speed CAN Module This document describes how to use the National Instruments 9853E board and includes dimensions, pin assignments, and specifications

More information

Process Control HPP-25

Process Control HPP-25 Process Control HPP-25 Riveting process monitoring 6 different control parameters Touchscreen operation Windows diagnostics software Industrie 4.0 ready...joining is our business worldwide! Process Control

More information

How to Order Manifold. Manifold mounting. DIN rail mounting style Direct mounting style

How to Order Manifold. Manifold mounting. DIN rail mounting style Direct mounting style Plug Lead Unit Series 000 [Option] How to Order Manifold S 0 FD D Electrical entry F kit D-sub connector kit P kit Kit type Flat ribbon cable connector kit J kit Flat ribbon cable (0P) (PC Wiring System

More information

User Manual for 24 GHz Blind-Spot Radar Sensor

User Manual for 24 GHz Blind-Spot Radar Sensor User Manual for 24 GHz Blind-Spot Radar Sensor SRR2-A Department: 1 of 13 AUTHORS Name Organisation Section Frank Gruson Continental, Frequency Management WW Issue Document Date of Issue Document Owner

More information

Process-Controller HPP-25

Process-Controller HPP-25 Process-Controller HPP-25 Riveting process monitoring 6 different control parameters Touchscreen operation Windows diagnostics software... joining is our business Process-Controller HPP-25 Riveting process

More information

Base Mounted Plug-in Unit

Base Mounted Plug-in Unit For details about certified products conforming to international standards, visit us at www.smcworld.com. 000 Plug-in Unit SI unit COM N V V C C C6 M CM 6 B B B6 B M 000 Manifold model Plug-in unit Stations

More information

SPAC265-8W. AC-DC power supply module. Features. Description. Applications

SPAC265-8W. AC-DC power supply module. Features. Description. Applications AC-DC power supply module Datasheet production data Features Open frame switch mode power supply European input voltage range Single output 5 V, 8 W peak power, 4 W continuous operating mode EMC compliance

More information

Series 10-ZSE30A(F)/10-ISE30A

Series 10-ZSE30A(F)/10-ISE30A Series 10-ZSEA(F)/10-ISEA RoHS 2-Color Display High-Precision Digital Pressure Switch Clean series For positive For vacuum/ compound Rated range ISEA 0.1 to 1 MPa How to Order 10 ISEA 01 N M 01 N01 C4H

More information

CONTROL MICROSYSTEMS SCADAWave Radio Transceiver. Hardware Manual

CONTROL MICROSYSTEMS SCADAWave Radio Transceiver. Hardware Manual 5908 SCADAWave Radio Transceiver Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9 Technical

More information

OPERATION MANUAL. Input Block EX250-IE1 EX250-IE2 EX250-IE3

OPERATION MANUAL. Input Block EX250-IE1 EX250-IE2 EX250-IE3 No.EX## - OME000 - A OPEATION MANUAL Input Block EX0-IE EX0-IE EX0-IE SMC Corporation Contents.Precautions ------------------------------------------ P.Specifications - General specification ------------------------------------------

More information

FP-RLY-420. Features. Installing the FP-RLY-420. FieldPoint Operating Instructions. Eight-Channel SPST Relay Module

FP-RLY-420. Features. Installing the FP-RLY-420. FieldPoint Operating Instructions. Eight-Channel SPST Relay Module FieldPoint Operating Instructions FP-RLY-420 Eight-Channel SPST Relay Module These operating instructions describe how to install and use the National Instruments FP-RLY-420 relay module, revision 185151C-01

More information

0.5seconds. 40mm. Fan Type Ionizer. Thinnest and Fastest. IZF Series. RoHS. The model with flow rate adjustment function added.

0.5seconds. 40mm. Fan Type Ionizer. Thinnest and Fastest. IZF Series. RoHS. The model with flow rate adjustment function added. Fan Type Ionizer RoHS Thinnest and Fastest Thickness 4 Rapid static neutralization.seconds M Extensive rapid static neutralization 3 [] New The model with flow rate adjustment function added. 2 s 4 s 6

More information

Preliminary. RF Data Transmission Rates 38.4, 115.2, 200 and 500 kbps

Preliminary. RF Data Transmission Rates 38.4, 115.2, 200 and 500 kbps Preliminary - 2.4 GHz RS-232C, RS-485/RS-232C and USB Serial Modems - Optional 128-Bit AES Encryption - Point-to-point, Point-to-multipoint, Peer-to-peer and Tree-routing Network Capabilities - Frequency

More information

RM24100D. Introduction. Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

RM24100D. Introduction. Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1. RM24100D 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE 802.15.4 compliant) Operating Manual English 1.09 Introduction The RM24100D radio modem acts as a wireless serial cable replacement and

More information

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance 1 High Accuracy Eddy Current Type Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1 guide... P.11~ General precautions... P.19 PHOTO PHOTO MEASURE panasonic.net/id/pidsx/global

More information

Instruction manual ADN-W AM. Antenna Module

Instruction manual ADN-W AM. Antenna Module Instruction manual ADN-W AM Antenna Module For your safety www www.sennheiser.com Manual Contents For your safety... 1 The ADN-W AM antenna module... 1 Package contents... 2 Components required for wireless

More information

SI unit PRODUCT NAME EX140-SCS1 EX140-SCS2

SI unit PRODUCT NAME EX140-SCS1 EX140-SCS2 No.EX##-OMF0012-A SI unit PRODUCT NAME EX140-SCS1 EX140-SCS2 MODEL/ Series Contents 1. Safety P 2 2. Outline P 6 3. Applicable solenoid valves P 6 4. Specifications P 7 5. Descriptions and Functions 5-1.

More information

MPR kHz Reader

MPR kHz Reader MPR-5005 Page 1 Doc# 041326 MPR-5005 125kHz Reader Installation & Operation Manual - 041326 MPR-5005 Page 2 Doc# 041326 COPYRIGHT ACKNOWLEDGEMENTS The contents of this document are the property of Applied

More information

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67g environment resistance

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67g environment resistance 13 High Accuracy Eddy Current Type Sensor SERIES Related Information General terms and conditions... F- Glossary of terms... P.139 Sensor selection guide... P.9~ General precautions... P.1 PHOTO PHOTO

More information

Instruction Manual MSC710 MSC710-U MSC710-I

Instruction Manual MSC710 MSC710-U MSC710-I Instruction Manual MSC710 MSC710-U MSC710-I Sensor controller for inductive displacement and gauging sensors series LVDT MICRO-EPSILON MESSTECHNIK GmbH & Co. KG Koenigbacher Strasse 15 94496 Ortenburg

More information

BNC-2121 Connector Accessory for 660X Devices

BNC-2121 Connector Accessory for 660X Devices USER GUIDE BNC-2121 Connector Accessory for 660X Devices The BNC-2121 connector accessory is a terminal block that connects signals to a 660X counter device and can be used to test features of a660x device.

More information

40 mm Beam Pitch General Purpose Area Sensor NA40 SERIES

40 mm Beam Pitch General Purpose Area Sensor NA40 SERIES 9 0 mm Beam Pitch General Purpose Area Sensor SERIES Related Information General terms and conditions... F- Glossary of terms / General precautions...p.59~ / P.55~ guide... P.9~ Korea s S-mark... P.60

More information

OPERATION MANUAL. SI unit EX120-SDN1 EX121-SDN1 EX122-SDN1 EX124D/U-SDN1

OPERATION MANUAL. SI unit EX120-SDN1 EX121-SDN1 EX122-SDN1 EX124D/U-SDN1 Doc.No. EX## -OME0015 OPERATION MANUAL SI unit EX120-SDN1 EX121-SDN1 EX122-SDN1 EX124D/U-SDN1 SMC Corporation Contents 1.Safety instructions ------------------------------------------------------ P3 2.Specifications

More information

Preliminary. DN-900 Series. 900 MHz Wireless Serial Modems

Preliminary. DN-900 Series. 900 MHz Wireless Serial Modems Preliminary - 900 MHz RS-232C, RS-485/RS-232C and USB Serial Modems - Optional 128-Bit AES Encryption - Point-to-point, Point-to-multipoint, Peer-to-peer and Tree-routing Network Capabilities - Frequency

More information

C2UW. Wireless Hand Switches. Model. System Configuration. Push Button Switch. Model Number Structure

C2UW. Wireless Hand Switches. Model. System Configuration. Push Button Switch. Model Number Structure Push Button Switch Wireless Hand Switches Operability that s highly flexible and has a high degree of freedom has been realized. There is no need to worry about staining, disconnection, and entangling

More information

RM24100A. *Maximum transmit power output levels and local radio frequency regulator bodies must be obeyed in the country of operation.

RM24100A. *Maximum transmit power output levels and local radio frequency regulator bodies must be obeyed in the country of operation. RM24100A 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE 802.15.4 compliant) Operating Manual English 1.02 Introduction The RM24100A radio modem acts as a wireless serial cable replacement and

More information

Walkie Talkie APMP300. User manual

Walkie Talkie APMP300. User manual Walkie Talkie User manual Table of contents 1. Safety 1 1.1 Intended use 3 1. Labels in this manual 3. Preparations for use.1 Unpacking 4. Package contents 5.3 Charge the battery.4 Insert batteries 3.

More information

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0 Touch Switch Unique 18 mm Capacitive Touch Switch with Choice of Three Actuators is Activated with Only a Very Slight Physical Contact Lightweight objects, such as thin wire or foil can be accurately detected.

More information

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control Gain Electronic Co. Ltd. Table Of Contents Safety Considerations ------------------------------------------------------------2

More information

SCXI CURRENT INPUT,HIGH-VOLTAGE TERMINAL BLOCK

SCXI CURRENT INPUT,HIGH-VOLTAGE TERMINAL BLOCK INSTALLATION GUIDE SCXI -1338 CURRENT INPUT,HIGH-VOLTAGE TERMINAL BLOCK Introduction This guide describes how to install and use the SCXI-1338 terminal block with your SCXI-1120, SCXI-1120D, SCXI-1125,

More information

FL WLAN 24 AP XDB and RAD XDB

FL WLAN 24 AP XDB and RAD XDB FL WLAN 24 AP 802-11 XDB and RAD-80211-XDB 802.11a/b/g Ethernet radio AUTOMATION Data sheet 2592_en_B 1 Description PHOENIX CONT 2011-10-18 3 Features The radios are industrial radio transceivers that

More information

DISCRETE INPUT MODULE, 16 points

DISCRETE INPUT MODULE, 16 points INSTRUCTION MANUAL DISCRETE INPUT MODULE, points (Modbus) RM-DA MODEL RM-DA BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.

More information

OPERATING INSTRUCTIONS NI Port DeviceNet Module

OPERATING INSTRUCTIONS NI Port DeviceNet Module OPERATING INSTRUCTIONS NI 9882 1-Port DeviceNet Module These operating instructions describe how to use the National Instruments (NI) 9882 module. For information about installing, configuring, and programming

More information

Distance-setting Photoelectric Sensor

Distance-setting Photoelectric Sensor Distance-setting Photoelectric Sensor The Combination of the Hyper LED and Shine-proof Achieves both Ease-of-use and High Performance Hyper LED mounted. Finest pin-point beam in the industry allows detection

More information

Connection targets. Universal sensors and switches, universal output devices

Connection targets. Universal sensors and switches, universal output devices AnyWireASLK System Products Guide ASLKTERMAL [ASLK Small Terminal Block Terminal] BL296 B-08F EURO block type The Products Guide describes individual products. Refer to the Guide as necessary. Function

More information

Technical Documentation

Technical Documentation Technical Documentation for metratec QuasarMX HF RFID Reader Date: April 2015 Version: 1.4 Technical Documentation metratec QuasarMX Page 1 of 13 Table of Contents 1 General Information / Security Advice...3

More information

Electronic Vacuum Regulator. How to Order ITV S 5. Monitor output

Electronic Vacuum Regulator. How to Order ITV S 5. Monitor output Electronic Vacuum Regulator Series ITV29/29 How to Order [Option] RoHS ITV 29 2 S 5 Pressure range 9.3 to 8 kpa Power supply voltage 24 VDC to 5 VDC Note) Communication models are available only for 24

More information

Specification Sym Notes Minimum Typical Maximum Units 900 MHz Operating Frequency Range MHz

Specification Sym Notes Minimum Typical Maximum Units 900 MHz Operating Frequency Range MHz 900 MHz FHSS DNT90/Ethernet Gateway Optional 128-Bit AES Encryption Point-to-point, Point-to-multipoint or Store and Forward Operation 158 mw EIRP 900 MHz Transmitter Power 10/100Base-T Auto-sensing Ethernet

More information

Original instructions INCA-1 Tina Emergency stop for enclosure installation INCA-1S Tina Safety stop for enclosure installation

Original instructions INCA-1 Tina Emergency stop for enclosure installation INCA-1S Tina Safety stop for enclosure installation Original instructions INCA-1 Tina Emergency stop for enclosure installation INCA-1S Tina Safety stop for enclosure installation ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/lowvoltage

More information

Scanning Laser Range Finder

Scanning Laser Range Finder Date: 2011.11.25 Scanning Laser Range Finder UTM-30LX-EW Specification Symbol Amendment Details Amendment Date Amended by Number Approved by Checked by Drawn by Designed by MORI KAMITANI TAGAMI HINO Drawing.

More information

Operating Manual. Differential Pressure Transmitter DPS 100

Operating Manual. Differential Pressure Transmitter DPS 100 Operating Manual Differential Pressure Transmitter DPS 100 Important notes: Please read this operating manual carefully before installing and starting up the pressure transmitter. This operating manual

More information

TT-208. User s Manual. 300Mps 5.8 GHz. IP Camera Wireless Transmission Kit

TT-208. User s Manual. 300Mps 5.8 GHz. IP Camera Wireless Transmission Kit TT-208 300Mps 5.8 GHz IP Camera Wireless Transmission Kit User s Manual V1.0 02 / 2014 Welcome Thank you for purchasing the TT-208 Wireless Transmission Kit for IP Cameras. This user s manual is designed

More information

Ethernet to 900 MHz RF Modem

Ethernet to 900 MHz RF Modem MLB-Z4001 Ethernet to 900 MHz RF Modem USER MANUAL MLB-Z4001 Terminal User Guide 1 Rev 1.0 Information provided by Schmidt & Co., (HK) Ltd, (herein known as the company ), is believed to be accurate and

More information

Regulatory Compliance Addendum for the Multi-Mode Wireless LAN Unit (WLU-2100)

Regulatory Compliance Addendum for the Multi-Mode Wireless LAN Unit (WLU-2100) Regulatory Compliance Addendum for the Multi-Mode Wireless LAN Unit (WLU-2100) 822-2210-001 CPN 963-4891-001 Rev - NOTICE: The contents of this document are proprietary to Rockwell Collins, Inc. and shall

More information

Installation & Operating Manual. iwap202

Installation & Operating Manual. iwap202 Installation & Operating Manual iwap202 This page is intentionally left blank. Document Number 409345 (based on 407655) (See Last Page for Revision Details) For warranty information, refer to Terms and

More information

RM24100D. Introduction. 1 Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

RM24100D. Introduction. 1 Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1. RM24100D 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE 802.15.4 compliant) Operating Manual English 1.03 Introduction The RM24100D radio modem acts as a wireless serial cable replacement and

More information

Type Sealing Poles Contact configuration Rated voltage Model. Type LED indicator Poles Rated voltage Model

Type Sealing Poles Contact configuration Rated voltage Model. Type LED indicator Poles Rated voltage Model Relays with Forcibly Guided Contacts CSM DS_E_6_ Compact, Slim Relays Conforming to EN Standards Relays with forcibly guided contacts (EN50205 Class A, certified by VDE). Supports the CE marking of machinery

More information

SureCross DX80 FlexPower EZ-LIGHT Node with Integrated Battery

SureCross DX80 FlexPower EZ-LIGHT Node with Integrated Battery SureCross DX80 FlexPower EZ-LIGHT Node with Integrated Battery Node with an integrated battery for the EZ-LIGHT family 900 MHz, Internal battery model Features The SureCross DX80 is a radio frequency network

More information

Name Model Specifications/Design ID Tag V700-D23P31 20 dia. t 2.7 mm Coin-shaped 256 bytes (with user area of 240 bytes)

Name Model Specifications/Design ID Tag V700-D23P31 20 dia. t 2.7 mm Coin-shaped 256 bytes (with user area of 240 bytes) Electromagnetic Inductive RFID System V700 A High-functionality High-performance RFID System That Revolutionizes Product and Distribution Management in the Production Environment A long transmission distance

More information

TL-W5MD1 2M *1 *3 TL-W5MD2 2M

TL-W5MD1 2M *1 *3 TL-W5MD2 2M Flat Inductive CSM DS_E_9_ Standard Flat s in Many Different Variations Only mm thick yet provides a sensing distance of mm (MC). Aluminum die-cast models also available. Be sure to read Safety Precautions

More information

LENORD. +BAUER... automates motion. MiniCoder GEL 2444K Speed and position sensor with metal housing and sin/cos output

LENORD. +BAUER... automates motion. MiniCoder GEL 2444K Speed and position sensor with metal housing and sin/cos output MiniCoder GEL 2444K Speed and position sensor with metal housing and sin/cos output LENORD +BAUER... automates motion. Technical information Version 03.3 General The measuring unit comprises a sensor and

More information

Safety light curtain to safeguard the hinge edge IMPORTANT NOTE

Safety light curtain to safeguard the hinge edge IMPORTANT NOTE Installation and Operation Manual CEDES MicroRay Safety light curtain to safeguard the hinge edge English EN 12978 EN 13849-1 IMPORTANT NOTE FOLLOW THE INSTRUCTIONS GIVEN IN THIS MANUAL CAREFULLY. FAILURE

More information

0.01kV (0 to ±0.99 kv)

0.01kV (0 to ±0.99 kv) Handheld Electrostatic Meter Series IZH10 Easy-to-use handheld electrostatic meter Rated charge amount range: ±20.0 kv Minimum display unit: 0.1kV (±1.0 to ±20.0 kv) Check the current situation before

More information

FP-DO-400 and cfp-do-400

FP-DO-400 and cfp-do-400 FieldPoint Operating Instructions FP-DO-400 and cfp-do-400 Eight-Channel, 5 30 V Digital Output Module These operating instructions describe how to install and use the National Instruments FP-DO-400 and

More information

Through-beam ring sensors

Through-beam ring sensors Throughbeam ring sensors Features Wide range of sizes: ring diameters of 10, 15 and 20 mm Metal housings Separate evaluation unit Connection by means of S8 connector Degree of protection IP 63 Adjustable

More information

Label Sensor. Ordering Information. Application Example E3S-CD68/CD63. Ideal for Detecting Labels on Bottles. E3S-CD68/CD63 Label Sensor

Label Sensor. Ordering Information. Application Example E3S-CD68/CD63. Ideal for Detecting Labels on Bottles. E3S-CD68/CD63 Label Sensor Ideal for Detecting Labels on Bottles Satisfies the requirements of IP67. Ensures a vibration resistance of 10 Hz to 2 khz and a shock resistance of 1,000 m/s 2 (approximately 100G). Incorporates an NPN

More information

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE (60A type only) RELAYS A PC board type 80A Connector type 60A Screw terminal type A TM type 300A Connector type RoHS Directive compatibility

More information

SI unit for DeviceNet TM

SI unit for DeviceNet TM PRODUCT NAME SI unitfor DeviceNet TM MODEL / Series / Product Number EX120-SDN1(-X2/-X26/-X77) EX121-SDN1(-X2/-X26/-X77) EX122-SDN1(-X2/-X26/-X77) EX124U/D-SDN1(-X2/-X26/-X77) Contents Safety Instructions

More information

Module Type Controller SRX. DeviceNet Communication Instruction Manual IMS01N17-E2 RKC INSTRUMENT INC.

Module Type Controller SRX. DeviceNet Communication Instruction Manual IMS01N17-E2 RKC INSTRUMENT INC. Module Type Controller SRX DeviceNet Communication Instruction Manual RKC INSTRUMENT INC. IMS01N17-E2 DeviceNet is a registered trademark of Open DeviceNet Vender Association, Inc. Modbus is a registered

More information

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description BAR--N-N-EX Antenna barrier for the hazardous area Data sheet 060_en_00 PHOENIX CONTACT 05-06-0 Description Using an antenna barrier, you can execute HF outputs of wireless modules with intrinsic safety.

More information

MINI MCR-SL-UI-I-LP-NC

MINI MCR-SL-UI-I-LP-NC 2-way isolation amplifier Data sheet 105263_en_02 PHOENIX CONTACT 2013-12-13 1 Description The configurable 2-way isolation amplifiers are used to electrically isolate, convert and filter standard signals.

More information

NI PXI-2521 Specifications 40-Channel DPST Relay Module

NI PXI-2521 Specifications 40-Channel DPST Relay Module NI PXI-2521 Specifications 40-Channel DPST Relay Module This document lists specifications for the NI PXI-2521 general-purpose relay module. All specifications are subject to change without notice. Visit

More information

NI Channel SPST Electromechanical Relay Module

NI Channel SPST Electromechanical Relay Module OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9481 4-Channel SPST Electromechanical Relay Module Français Deutsch ni.com/manuals This document describes how to use the National Instruments 9481 and includes

More information

AcuMesh Wireless RS485 Network. User's Manual SOLUTION

AcuMesh Wireless RS485 Network. User's Manual SOLUTION AcuMesh Wireless RS485 Network User's Manual AN SOLUTION ACUMESH - WIRELESS METERING SYSTEM COPYRIGHT 2015 V1.2 This manual may not be altered or reproduced in whole or in part by any means without the

More information

Distance-setting Photoelectric Sensor

Distance-setting Photoelectric Sensor Distance-setting Photoelectric Sensor The Combination of the Hyper LED and Shine-proof Achieves both Ease-of-use andhighperformance Hyper LED mounted. Finest pin-point beam in the industry allows detection

More information

NI Channel, Universal Digital Input Module

NI Channel, Universal Digital Input Module OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9435 4-Channel, Universal Digital Input Module Français Deutsch ni.com/manuals This document describes how to use the National Instruments 9435 and includes

More information

Multilin DGT. Distributed Generation Trip Control Fast & Wireless Trip of Distributed Generators. Control. Advanced Communications

Multilin DGT. Distributed Generation Trip Control Fast & Wireless Trip of Distributed Generators. Control. Advanced Communications Multilin DGT Distributed Generation Trip Control Fast & Wireless Trip of Distributed Generators The desire for green power and rapid developments in renewable energy sources are driving the growth of distributed

More information

Operator s Manual. PP016 Passive Probe

Operator s Manual. PP016 Passive Probe Operator s Manual PP016 Passive Probe 2017 Teledyne LeCroy, Inc. All rights reserved. Unauthorized duplication of Teledyne LeCroy documentation materials is strictly prohibited. Customers are permitted

More information

Frame through-beam sensors

Frame through-beam sensors Frame through-beam sensors Features Wide range of sizes: passage sizes from 25 x 23 mm to 300 x 397.5 mm Metal housings Integrated evaluation unit Connection by means of connector Degree of protection

More information

NA1-11. Small / Slim Object Detection Area Sensor. Cross-beam scanning system to detect slim objects

NA1-11. Small / Slim Object Detection Area Sensor. Cross-beam scanning system to detect slim objects 929 PHOTO PHOTO MEASURE Object Area Sensor General terms and conditions... F-3 Related Information Glossary of terms... P.1549~ panasonic.net/id/pidsx/global guide...p.85~ General precautions... P.1552~

More information

Type Poles Contact configuration Rated voltage Model G7S-4A2B 24 VDC 3PST-NO, 3PST-NC

Type Poles Contact configuration Rated voltage Model G7S-4A2B 24 VDC 3PST-NO, 3PST-NC Relays with Forcibly Guided Contacts G7S CSM_G7S_DS_E_5_ Relays Conforming to EN Standard Relays with forcibly guided contacts (EN50205 Class A, certified by VDE). Supports the CE marking of machinery

More information

Trio K-Series. License-free serial data radio KR900 KR240 KP900 KP240 KB900 KB240

Trio K-Series. License-free serial data radio KR900 KR240 KP900 KP240 KB900 KB240 Trio K-Series License-free serial data radio KR900 KR240 KP900 KP240 KB900 KB240 1 Trio K-Series frequency-hopping, spread-spectrum data radios set the standard for reliable and secure serial data communication

More information

Quick Start Guide. ELPRO 905U-L-T Wireless I/O Transmitter Unit. man_905u-l-t_quickstart_v1.9.doc

Quick Start Guide. ELPRO 905U-L-T Wireless I/O Transmitter Unit. man_905u-l-t_quickstart_v1.9.doc Quick Start Guide ELPRO 905U-L-T Wireless I/O Transmitter Unit man_905u-l-t_quickstart_v1.9.doc About this document This document is the and contains the following sections: Section Basic steps for using

More information

W 140: Miniature Photoelectric Switch Series with Large Scanning Ranges

W 140: Miniature Photoelectric Switch Series with Large Scanning Ranges W : iniature Photoelectric Switch Series with Large Scanning Ranges Photoelectric proximity switch with adjustable scanning distance and background suppression (BGS): Scanning distance = adjustable up

More information

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35 www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up

More information

NI Channel, TTL Digital Input/Output Module

NI Channel, TTL Digital Input/Output Module OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9401 8-Channel, TTL Digital Input/Output Module Français Deutsch ni.com/manuals This document describes how to use the National Instruments 9401 and includes

More information

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9211E 4-Channel Thermocouple Input Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9211E 4-Channel Thermocouple Input Module OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9211E 4-Channel Thermocouple Input Module This document describes how to use the National Instruments 9211E and includes dimensions, terminal assignments, and

More information

SPECIAL SPECIFICATION 1806 Spread Spectrum Wireless Modem

SPECIAL SPECIFICATION 1806 Spread Spectrum Wireless Modem 1993 Specifications CSJ s 0902-48-442 & 0902-48-432 SPECIAL SPECIFICATION 1806 Spread Spectrum Wireless Modem 1. General. This Item shall govern for the furnishing and installation of Spread Spectrum Wireless

More information

SCC-DI01 Isolated Digital Input Module

SCC-DI01 Isolated Digital Input Module USER GUIDE SCC-DI01 Isolated Digital Input Module Conventions The SCC-DI01 is a single-channel, optically isolated digital input module that can sense AC and DC digital signals, including TTL, up to 30

More information

Instruction Manual for Universal Ku-band 8W BUC [NJT5218 series]

Instruction Manual for Universal Ku-band 8W BUC [NJT5218 series] Instruction Manual for Universal Ku-band 8W BUC [NJT5218 series] Document Part Number: IM-T5218 Revision: 00 Issue Date: June 15, 2012 Copyright 2012, New Japan Radio Co., Ltd. All rights reserved. This

More information

Installing the IPS 4240 and the IPS 4255

Installing the IPS 4240 and the IPS 4255 CHAPTER 2 Installing the IPS 4240 and the IPS 4255 All IPS platforms allow ten concurrent CLI sessions. This chapter describes the IPS 4240 and the IPS 4255 and how to install them. It also describes the

More information

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE RELAYS (60A type only) A PC board type A TM type 60A Screw terminal type 80A Connector type 300A Connector type Compliance with RoHS Directive

More information

Accutech BR20. DIN rail mounted base radio

Accutech BR20. DIN rail mounted base radio Accutech BR20 DIN rail mounted base radio 1 At the heart of any Accutech wireless instrument network is the wireless base radio. The Accutech BR20 automatically communicates with deployed instrumentation

More information

External brake resistor AX2090-BW5x

External brake resistor AX2090-BW5x Documentation External brake resistor AX2090-BW5x Accessories for Beckhoff servo drive AX5000 Version: Date: 1.3 2018-03-14 Table of content Table of content 1 Foreword... 5 1.1 Notes on the documentation...

More information

INFRARED WIRELESS DISTRIBUTOR

INFRARED WIRELESS DISTRIBUTOR OPERATING INSTRUCTIONS INFRARED WIRELESS DISTRIBUTOR IR-700D Thank you for purchasing TOA's Infrared Wireless Distributor. Please carefully follow the instructions in this manual to ensure long, trouble-free

More information

NI PXI-2520 Specifications 80-Channel SPST Relay Module

NI PXI-2520 Specifications 80-Channel SPST Relay Module NI PXI-2520 Specifications 80-Channel SPST Relay Module This document lists specifications for the NI PXI-2520 general-purpose relay module. All specifications are subject to change without notice. Visit

More information

Mounting instruction and operating manual. Access Point (UK) HmIP-HAP-UK

Mounting instruction and operating manual. Access Point (UK) HmIP-HAP-UK Mounting instruction and operating manual Access Point (UK) HmIP-HAP-UK Package contents Quantity Description 1 Homematic IP Access Point (UK) 1 Plug-in mains adapter 1 Network cable 2 Screws 2 Plugs 1

More information

30 A AC/DC Current Probe TCP0030A Datasheet

30 A AC/DC Current Probe TCP0030A Datasheet 30 A AC/DC Current Probe TCP0030A Datasheet Split-core construction allows easy circuit connection High accuracy with typically less than 1% DC gain error Low noise and DC drift 3rd party safety certification

More information

PROFIBUS HUB REPEATER

PROFIBUS HUB REPEATER USER S MANUAL PROFIBUS HUB REPEATER RHP303 R H P 3 0 3 M E smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

More information

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9207E 16-Channel, ±20 ma/±10 V, 24-Bit Analog Input Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9207E 16-Channel, ±20 ma/±10 V, 24-Bit Analog Input Module OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9207E 16-Channel, ±20 ma/±10 V, 24-Bit Analog Input Module This document describes how to use the National Instruments 9207E and includes dimensions, pin assignments,

More information

2-channel speed sensor GEL 247 Compact sensor for harsh applications

2-channel speed sensor GEL 247 Compact sensor for harsh applications 2-channel speed sensor GEL 247 Compact sensor for harsh applications Technical information Version 01.11 General Speed sensor based on magnetic measurement principle Maintenance- and wear-free operation

More information

M-0418 REV:0

M-0418 REV:0 1 of 5 This specification sets forth the minimum requirements for purchase and installation of an aboveground Radar Detection Device (RDD) system for a real-time, stop bar vehicle-detection system that

More information

MICROFUSION SINGLE PHASE SCR POWER CONTROLLERS

MICROFUSION SINGLE PHASE SCR POWER CONTROLLERS CONTROL CONCEPTS MICROFUSION SINGLE PHASE SCR POWER CONTROLLERS FEATURES Auto-Ranging Input Voltage UL: 24-600 Vac, 45-65 Hz CE: 24-690 Vac, 45-65 Hz AC Output 8, 16, 32, 50, 80, 100, 130, 160, 200, 240,

More information

ORiNOCO AP-4000MR-LR and AP-4900MR-LR Access Points Safety and Regulatory Compliance Information

ORiNOCO AP-4000MR-LR and AP-4900MR-LR Access Points Safety and Regulatory Compliance Information IMPORTANT! Visit http://support.proxim.com for the latest safety and regulatory compliance information for this product. ORiNOCO AP-4000MR-LR and AP-4900MR-LR Access Points Safety and Regulatory Compliance

More information

RM24100A. Introduction. 1 Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

RM24100A. Introduction. 1 Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1. RM24100A 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE 802.15.4 compliant) Operating Manual English 1.03 Introduction The RM24100A radio modem acts as a wireless serial cable replacement and

More information